Sample records for beam rib facility

  1. The South African isotope facility project

    NASA Astrophysics Data System (ADS)

    Bark, R. A.; Barnard, A. H.; Conradie, J. L.; de Villiers, J. G.; van Schalkwyk, P. A.

    2018-05-01

    The South African Isotope Facility (SAIF) is a project in which iThemba LABS plans to build a radioactive-ion beam (RIB) facility. The project is divided into the Accelerator Centre of Exotic Isotopes (ACE Isotopes) and the Accelerator Centre for Exotic Beams (ACE Beams). For ACE Isotopes, a high-current, 70 MeV cyclotron will be acquired to take radionuclide production off the existing Separated Sector Cyclotron (SSC). A freed up SSC will then be available for an increased tempo of nuclear physics research and to serve as a driver accelerator for the ACE Beams project, in which protons will be used for the direct fission of Uranium, producing beams of fission fragments. The ACE Beams project has begun with "LeRIB" - a Low Energy RIB facility, now under construction. In a collaboration with INFN Legnaro, the target/ion-source "front-end" will be a copy of the front-end developed for the SPES project. A variety of targets may be inserted into the SPES front-end; a uranium-carbide target has been designed to produce up to 2 × 1013 fission/s using a 70 MeV proton beam of 150 µA intensity.

  2. The Alto Tandem and Isol Facility at IPN Orsay

    NASA Astrophysics Data System (ADS)

    Franchoo, Serge

    Alto is an infrastructure for experimental nuclear physics in France that comprises both an on-line isotope-separation facility based on the photofission of uranium and a stable-ion beam facility based on a 14.5-MV tandem accelerator. The isotope-separation on-line section of Alto is dedicated to the production of neutron-rich radioactive ion beams (RIB) from the interaction of the γ-flux induced by a 50-MeV 10-µA electron beam in a uranium-carbide target. It is dimensioned for 1011 fissions per second. The RIB facility is exploited in alternating mode with the tandem-based section of Alto, capable of accelerating both light ions for nuclear astrophysics and heavy ions for γ-spectroscopy. The facility thereby offers the opportunity to deliver beams to a large range of physics programmes from nuclear to interdisciplinary physics. In this article, we present the Alto facility as well as some of the highlights and prospects of the experimental programme.

  3. The RIB production target for the SPES project

    NASA Astrophysics Data System (ADS)

    Monetti, Alberto; Andrighetto, Alberto; Petrovich, Carlo; Manzolaro, Mattia; Corradetti, Stefano; Scarpa, Daniele; Rossetto, Francesco; Martinez Dominguez, Fernando; Vasquez, Jesus; Rossignoli, Massimo; Calderolla, Michele; Silingardi, Roberto; Mozzi, Aldo; Borgna, Francesca; Vivian, Gianluca; Boratto, Enrico; Ballan, Michele; Prete, Gianfranco; Meneghetti, Giovanni

    2015-10-01

    Facilities making use of the Isotope Separator On-Line (ISOL) method for the production of Radioactive Ion Beams (RIB) attract interest because they can be used for nuclear structure and reaction studies, astrophysics research and interdisciplinary applications. The ISOL technique is based on the fast release of the nuclear reaction products from the chosen target material together with their ionization into short-lived nuclei beams. Within this context, the SPES (Selective Production of Exotic Species) facility is now under construction in Italy at INFN-LNL (Istituto Nazionale di Fisica Nucleare — Laboratori Nazionali di Legnaro). The SPES facility will produce RIBs mainly from n-rich isotopes obtained by a 40 MeV cyclotron proton beam (200 μA) directly impinging on a uranium carbide multi-foil fission target. The aim of this work is to describe and update, from a comprehensive point of view, the most important results obtained by the analysis of the on-line behavior of the SPES production target assembly. In particular an improved target configuration has been studied by comparing different codes and physics models: the thermal analyses and the isotope production are re-evaluated. Then some consequent radioprotection aspects, which are essential for the installation and operation of the facility, are presented.

  4. Ion traps for precision experiments at rare-isotope-beam facilities

    NASA Astrophysics Data System (ADS)

    Kwiatkowski, Anna

    2016-09-01

    Ion traps first entered experimental nuclear physics when the ISOLTRAP team demonstrated Penning trap mass spectrometry of radionuclides. From then on, the demand for ion traps has grown at radioactive-ion-beam (RIB) facilities since beams can be tailored for the desired experiment. Ion traps have been deployed for beam preparation, from bunching (thereby allowing time coincidences) to beam purification. Isomerically pure beams needed for nuclear-structure investigations can be prepared for trap-assisted or in-trap decay spectroscopy. The latter permits studies of highly charged ions for stellar evolution, which would be impossible with traditional experimental nuclear-physics methods. Moreover, the textbook-like conditions and advanced ion manipulation - even of a single ion - permit high-precision experiments. Consequently, the most accurate and precise mass measurements are now performed in Penning traps. After a brief introduction to ion trapping, I will focus on examples which showcase the versatility and utility of the technique at RIB facilities. I will demonstrate how this atomic-physics technique has been integrated into nuclear science, accelerator physics, and chemistry. DOE.

  5. A neutron beam facility for radioactive ion beams and other applications

    NASA Astrophysics Data System (ADS)

    Tecchio, L. B.

    1999-06-01

    In the framework of the Italian participation in the project of a high intensity proton facility for the energy amplifier and nuclear waste transmutations, LNL is involved in the design and construction of same prototypes of the injection system of the 1 GeV linac that consists of a RFQ (5 MeV, 30 mA) followed by a 100 MeV linac. This program has already been supported financially and the work is in progress. In this context LNL has proposed a project for the construction of a second generation facility for the production of radioactive ion beams (RIBs) by means of the ISOL method. The final goal is the production of neutron rich RIBs with masses ranging from 30 to 150 by using primary beams of protons, deuterons and light ions with energy of 100 MeV and 100 kW power. This project is expected to be developed in about 10 years from new and intermediate milestones and experiments are foreseen and under consideration for the next INFN five year plan (1999-2003). During that period the construction of a proton/deuteron accelerator of 10 MeV energy and 10 mA current, consisting of a RFQ (5 MeV, 30 mA) and a linac (10 MeV, 10 mA), and of a neutron area dedicated to the RIBs production and to the neutron physics, is proposed. Some remarks on the production methods will be presented. The possibility of producing radioisotopes by means of the fission induced by neutrons will be investigated and the methods of production of neutrons will be discussed. Besides the RIBs production, neutron beams for the BNCT applications and neutron physics are also planned.

  6. Spes: An intense source of Neutron-Rich Radioactive Beams at Legnaro

    NASA Astrophysics Data System (ADS)

    Andrighetto, A.; Manzolaro, M.; Corradetti, S.; Scarpa, D.; Monetti, A.; Rossignoli, M.; Ballan, M.; Borgna, F.; D'Agostini, F.; Gramegna, F.; Prete, G.; Meneghetti, G.; Ferrari, M.; Zenoni, A.

    2018-02-01

    The Isotope Separation On-Line (ISOL) method for the production of Radioactive Ion Beams (RIB) is attracting significant interest in the worldwide nuclear physics community. Within this context the SPES (Selective Production of Exotic Species) RIB facility is now under construction at INFN LNL (Istituto Nazionale di Fisica Nucleare Laboratori Nazionali di Legnaro). This technique is established as one of the main techniques for high intensity and high quality beams production. The SPES facility will produce n-rich isotopes by means of a 40 MeV proton beam, emitted by a cyclotron, impinging on a uranium carbide multi-foil fission target. The aim of this work is to describe the most important results obtained by the study of the on-line behavior of the SPES production target assembly. This target system will produce RIBs at a rate of about 1013 fissions per second, it will be able to dissipate a total power of up to 10 kW, and it is planned to work continuously for 2 week-runs of irradiation. ISOL beams of 24 different elements will be produced, therefore a target and ion source development is ongoing to ensure a great variety of produced isotopes and to improve the beam intensity and purity.

  7. A combined thermal dissociation and electron impact ionization source for RIB generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alton, G.D.; Williams, C.

    1995-12-31

    The probability for simultaneously dissociating and efficiently ionizing the individual atomic constituents of molecular feed materials with conventional, hot-cathode, electron-impact ion sources is low and consequently, the ion beams from these sources often appear as mixtures of several molecular sideband beams. This fragmentation process leads to dilution of the intensity of the species of interest for RIB applications where beam intensity is at a premium. We have conceived an ion source that combines the excellent molecular dissociation properties of a thermal dissociator and the high ionization efficiency characteristics of an electron impact ionization source that will, in principle, overcome thismore » handicap. The source concept will be evaluated as a potential candidate for use for RIB generation at the Holifield Radioactive Ion Beam Facility (HRIBF), now under construction at the Oak Ridge National Laboratory. The design features and principles of operation of the source are described in this article.« less

  8. The Neutrons for Science Facility at SPIRAL-2

    NASA Astrophysics Data System (ADS)

    Ledoux, X.; Aïche, M.; Avrigeanu, M.; Avrigeanu, V.; Audouin, L.; Balanzat, E.; Ban-détat, B.; Ban, G.; Barreau, G.; Bauge, E.; Bélier, G.; Bem, P.; Blideanu, V.; Borcea, C.; Bouffard, S.; Caillaud, T.; Chatillon, A.; Czajkowski, S.; Dessagne, P.; Doré, D.; Fallot, M.; Farget, F.; Fischer, U.; Giot, L.; Granier, T.; Guillous, S.; Gunsing, F.; Gustavsson, C.; Jacquot, B.; Jansson, K.; Jurado, B.; Kerveno, M.; Klix, A.; Landoas, O.; Lecolley, F. R.; Lecouey, J. L.; Majerle, M.; Marie, N.; Materna, T.; Mrazek, J.; Negoita, F.; Novak, J.; Oberstedt, S.; Oberstedt, A.; Panebianco, S.; Perrot, L.; Plompen, A. J. M.; Pomp, S.; Ramillon, J. M.; Ridikas, D.; Rossé, B.; Rudolf, G.; Serot, O.; Simakov, S. P.; Simeckova, E.; Smith, A. G.; Sublet, J. C.; Taieb, J.; Tassan-Got, L.; Tarrio, D.; Takibayev, A.; Thfoin, I.; Tsekhanovich, I.; Varignon, C.

    2014-05-01

    The Neutrons For Science (NFS) facility is a component of SPIRAL-2 laboratory under construction at Caen (France). SPIRAL-2 is dedicated to the production of high intensity Radioactive Ions Beams (RIB). It is based on a high-power linear accelerator (LINAG) to accelerate deuterons beams in order to produce neutrons by breakup reactions on a C converter. These neutrons will induce fission in 238U for production of radioactive isotopes. Additionally to the RIB production, the proton and deuteron beams delivered by the accelerator will be used in the NFS facility. NFS is composed of a pulsed neutron beam and irradiation stations for cross-section measurements and material studies. The beams delivered by the LINAG will allow producing intense neutron beams in the 100 keV-40 MeV energy range with either a continuous or quasi-mono-energetic spectrum. At NFS available average fluxes will be up to 2 orders of magnitude higher than those of other existing time-of-flight facilities in the 1 MeV - 40 MeV range. NFS will be a very powerful tool for fundamental physics and application related research in support of the transmutation of nuclear waste, design of future fission and fusion reactors, nuclear medicine or test and development of new detectors. The facility and its characteristics are described, and several examples of the first potential experiments are presented.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moon, Chang-Bum, E-mail: cbmoon@hoseo.edu

    This paper outlines the new physics possibilities that fall within the field of nuclear structure and astrophysics based on experiments with radioactive ion beams at the future Rare Isotope Beams Accelerator facility in Korea. This ambitious multi-beam facility has both an Isotope Separation On Line (ISOL) and fragmentation capability to produce rare isotopes beams (RIBs) and will be capable of producing and accelerating beams of wide range mass of nuclides with energies of a few to hundreds MeV per nucleon. The large dynamic range of reaccelerated RIBs will allow the optimization in each nuclear reaction case with respect to crossmore » section and channel opening. The low energy RIBs around Coulomb barrier offer nuclear reactions such as elastic resonance scatterings, one or two particle transfers, Coulomb multiple-excitations, fusion-evaporations, and direct capture reactions for the study of the very neutron-rich and proton-rich nuclides. In contrast, the high energy RIBs produced by in-flight fragmentation with reaccelerated ions from the ISOL enable to explore the study of neutron drip lines in intermediate mass regions. The proposed studies aim at investigating the exotic nuclei near and beyond the nucleon drip lines, and to explore how nuclear many-body systems change in such extreme regions by addressing the following topics: the evolution of shell structure in areas of extreme proton to neutron imbalance; the study of the weak interaction in exotic decay schemes such as beta-delayed two-neutron or two-proton emission; the change of isospin symmetry in isobaric mirror nuclei at the drip lines; two protons or two neutrons radioactivity beyond the drip lines; the role of the continuum states including resonant states above the particle-decay threshold in exotic nuclei; and the effects of nuclear reaction rates triggered by the unbound proton-rich nuclei on nuclear astrophysical processes.« less

  10. The experimental set-up of the RIB in-flight facility EXOTIC

    NASA Astrophysics Data System (ADS)

    Pierroutsakou, D.; Boiano, A.; Boiano, C.; Di Meo, P.; La Commara, M.; Manea, C.; Mazzocco, M.; Nicoletto, M.; Parascandolo, C.; Signorini, C.; Soramel, F.; Strano, E.; Toniolo, N.; Torresi, D.; Tortone, G.; Anastasio, A.; Bettini, M.; Cassese, C.; Castellani, L.; Corti, D.; Costa, L.; De Fazio, B.; Galet, G.; Glodariu, T.; Grebosz, J.; Guglielmetti, A.; Molini, P.; Pontoriere, G.; Rocco, R.; Romoli, M.; Roscilli, L.; Sandoli, M.; Stroe, L.; Tessaro, M.; Zatti, P. G.

    2016-10-01

    We describe the experimental set-up of the Radioactive Ion Beam (RIB) in-flight facility EXOTIC consisting of: (a) two position-sensitive Parallel Plate Avalanche Counters (PPACs), dedicated to the event-by-event tracking of the produced RIBs and to time of flight measurements and (b) the new high-granularity compact telescope array EXPADES (EXotic PArticle DEtection System), designed for nuclear physics and nuclear astrophysics experiments employing low-energy light RIBs. EXPADES consists of eight ΔE -Eres telescopes arranged in a cylindrical configuration around the target. Each telescope is made up of two Double Sided Silicon Strip Detectors (DSSSDs) with a thickness of 40/60 μm and 300 μm for the ΔE and Eres layer, respectively. Additionally, eight ionization chambers were constructed to be used as an alternative ΔE stage or, in conjunction with the entire DSSSD array, to build up more complex triple telescopes. New low-noise multi-channel charge-sensitive preamplifiers and spectroscopy amplifiers, associated with constant fraction discriminators, peak-and-hold and Time to Amplitude Converter circuits were developed for the electronic readout of the ΔE stage. Application Specific Integrated Circuit-based electronics was employed for the treatment of the Eres signals. An 8-channel, 12-bit multi-sampling 50 MHz Analog to Digital Converter, a Trigger Supervisor Board for handling the trigger signals of the whole experimental set-up and an ad hoc data acquisition system were also developed. The performance of the PPACs, EXPADES and of the associated electronics was obtained offline with standard α calibration sources and in-beam by measuring the scattering process for the systems 17O+58Ni and 17O+208Pb at incident energies around their respective Coulomb barriers and, successively, during the first experimental runs with the RIBs of the EXOTIC facility.

  11. UCx target preparations and characterizations

    NASA Astrophysics Data System (ADS)

    Andrighetto, Alberto; Corradetti, Stefano; Manzolaro, Mattia; Scarpa, Daniele; Monetti, Alberto; Rossignoli, Massimo; Borgna, Francesca; Ballan, Michele; Agostini, Mattia; D'Agostini, Fabio; Ferrari, Matteo; Zenoni, Aldo

    2018-05-01

    The Target-Ion Source unit is the core of an ISOL-RIB facility. Many international ISOL facilities have chosen different layouts of this unit. Many research groups are involved in research and development of targets capable of dissipating high power and, at the same time, be able to have a fast isotope release. This is mandatory in order to produce beams of short half-life isotopes. The research of new materials with advanced microstructural features is crucial in this field. The design of a proper target is indeed strictly related to the obtainment of porous refractory materials, which are capable to work under extreme conditions (temperatures up to 2000 °C in high vacuum) with a high release efficiency. For SPES, the second generation Italian ISOL-RIB Facility, the target will be made of uranium carbide (UCx) in which, by fission induced by a proton beam of 40 MeV of energy (8 kW of power), isotopes in the 60-160 amu mass region are produced. The current technological developments are also crucial in the study of third generation ISOL facilities.

  12. A combined thermal dissociation and electron impact ionization source for radioactive ion beam generation{sup a}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alton, G.D.; Williams, C.

    1996-04-01

    The probability for simultaneously dissociating and efficiently ionizing the individual atomic constituents of molecular feed materials with conventional, hot-cathode, electron-impact ion sources is low and consequently, the ion beams from these sources often appear as mixtures of several molecular sideband beams. This fragmentation process leads to dilution of the intensity of the species of interest for radioactive ion beam (RIB) applications where beam intensity is at a premium. We have conceived an ion source that combines the excellent molecular dissociation properties of a thermal dissociator and the high ionization efficiency characteristics of an electron impact ionization source that will, inmore » principle, overcome this handicap. The source concept will be evaluated as a potential candidate for use for RIB generation at the Holifield Radioactive Ion Beam Facility, now under construction at the Oak Ridge National Laboratory. The design features and principles of operation of the source are described in this article. {copyright} {ital 1996 American Institute of Physics.}« less

  13. A combined thermal dissociation and electron impact ionization source for radioactive ion beam generation (abstract){sup a}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alton, G.D.; Williams, C.

    1996-03-01

    The probability for simultaneously dissociating and efficiently ionizing the individual atomic constituents of molecular feed materials with conventional, hot-cathode, electron-impact ion sources is low and consequently, the ion beams from these sources often appear as mixtures of several molecular sideband beams. This fragmentation process leads to dilution of the intensity of the species of interest for radioactive ion beam (RIB) applications where beam intensity is at a premium. We have conceived an ion source that combines the excellent molecular dissociation properties of a thermal dissociator and the high ionization efficiency characteristics of an electron impact ionization source that will, inmore » principle, overcome this handicap. The source concept will be evaluated as a potential candidate for use for RIB generation at the Holifield Radioactive Ion Beam Facility, now under construction at the Oak Ridge National Laboratory. The design features and principles of operation of the source are described in this article. {copyright} {ital 1996 American Institute of Physics.}« less

  14. The RIB facility EXOTIC and its experimental program at INFN-LNL

    NASA Astrophysics Data System (ADS)

    Parascandolo, Concetta

    2018-05-01

    In this contribution, I will present a review about the EXOTIC facility and the research field accessible by using its Radioactive Ion Beams. The EXOTIC facility, installed at the INFN-Laboratori Nazionali di Legnaro, is devoted to the in-flight production of light Radioactive Ion Beams in the energy range between 3-5 MeV/nucleon. The scientific activity performed at EXOTIC concerns different aspects of nuclear physics and nuclear astrophysics, such as, the investigation of reaction mechanisms and nuclear structure, resonant scattering experiments and measurements of nuclear reaction cross sections of astrophysical interest.

  15. The radioactive ion beams facility project for the legnaro laboratories

    NASA Astrophysics Data System (ADS)

    Tecchio, Luigi B.

    1999-04-01

    In the frame work of the Italian participation to the project of a high intensity proton facility for the energy amplifier and nuclear waste transmutations, LNL is involving in the design and construction of prototypes of the injection system of the 1 GeV linac that consists of a RFQ (5 MeV, 30 mA) followed by a 100 MeV linac. This program has been already financially supported and the work is actually in progress. In this context, the LNL has been proposed a project for the construction of a second generation facility for the production of radioactive ion beams (RIBs) by using the ISOL method. The final goal consists in the production of neutron rich RIBs with masses ranging from 80 to 160 by using primary beams of protons, deuterons and light ions with energy of 100 MeV and 100 kW power. This project is proposed to be developed in about 10 years from now and intermediate milestones and experiments are foreseen and under consideration for the next INFN five year plan (1999-2003). In such period of time is proposed the construction of a proton/deuteron accelerator of 10 MeV energy and 10 mA current, consisting of a RFQ (5 MeV, 30 mA) and a linac (10 MeV, 10 mA), and of a neutron area dedicated to the RIBs production, to the BNCT applications and to the neutron physics. Some remarks on the production methods will be presented. The possibility of producing radioisotopes by means of the fission induced by neutrons will be investigated and the methods of production of neutrons will be discussed.

  16. Design and development of a radio frequency quadrupole linac postaccelerator for the Variable Energy Cyclotron Center rare ion beam project.

    PubMed

    Dechoudhury, S; Naik, V; Mondal, M; Chatterjee, A; Pandey, H K; Mandi, T K; Bandyopadhyay, A; Karmakar, P; Bhattacharjee, S; Chouhan, P S; Ali, S; Srivastava, S C L; Chakrabarti, A

    2010-02-01

    A four-rod type heavy-ion radio frequency quadrupole (RFQ) linac has been designed, constructed, and tested for the rare ion beam (RIB) facility project at VECC. Designed for cw operation, this RFQ is the first postaccelerator in the RIB beam line. It will accelerate A/q < or = 14 heavy ions coming from the ion source to the energy of around 100 keV/u for subsequent acceleration in a number of Interdigital H-Linac. Operating at a resonance frequency of 37.83 MHz, maximum intervane voltage of around 54 kV will be needed to achieve the final energy over a vane length of 3.12 m for a power loss of 35 kW. In the first beam tests, transmission efficiency of about 90% was measured at the QQ focus after the RFQ for O(5+) beam. In this article the design of the RFQ including the effect of vane modulation on the rf characteristics and results of beam tests will be presented.

  17. Physics with Heavy Neutron Rich Ribs at the Hribf

    NASA Astrophysics Data System (ADS)

    Radford, David

    2002-10-01

    The Holifield Radioactive Ion Beam Facility at the Oak Ridge National Laboratory has recently produced the world's first post-accelerated beams of heavy neutron-rich nuclei. B(E2;0^+ arrow 2^+) values for neutron-rich ^126,128Sn and ^132,134,136Te isotopes have been measured by Coulomb excitation of radioactive ion beams in inverse kinematics. The results for ^132Te and ^134Te (N=80,82) show excellent agreement with systematics of lighter Te isotopes, but the B(E2) value for ^136Te (N=84) is unexpectedly small. Single-neutron transfer reactions leading to ^135Te were identified using a ^134Te beam on ^natBe and ^13C targets at energies just above the Coulomb barrier. The use of the Be target provided an unambiguous signature for neutron transfer through the detection of two correlated α particles, arising from the breakup of unstable ^8Be. The results of these experiments will be discussed, togther with plans for future experiments with these heavy n-rich RIBs.

  18. Molecular-Flow Properties of RIB Type Vapor-Transport Systems Using a Fast-Valve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alton, Gerald D; Bilheux, Hassina Z; Zhang, Y.

    2014-01-01

    The advent of the fast-valve device, described previously, permits measurement of molecular-flow times of chemically active or inactive gaseous species through radioactive ion beam (RIB) target ion source systems, independent of size, geometry and materials of construction. Thus, decay losses of short-half-life RIBs can be determined for a given target/vapor-transport system in advance of on-line operation, thereby ascertaining the feasibility of the system design for successful processing of a given isotope. In this article, molecular-flow-time theory and experimentally measured molecular-flow time data are given for serial- and parallel-coupled Ta metal RIB vapor-transport systems similar to those used at ISOL basedmore » RIB facilities. In addition, the effect of source type on the molecular-flow time properties of a given system is addressed, and a chemical passivation method for negating surface adsorption enthalpies for chemically active gaseous species on Ta surfaces is demonstrated.« less

  19. Nuclear Structure Studies with Stable and Radioactive Beams: The SPES radioactive ion beam project

    NASA Astrophysics Data System (ADS)

    de Angelis, G.; SPES Collaboration; Prete, G.; Andrighetto, A.; Manzolaro, M.; Corradetti, S.; Scarpa, D.; Rossignoli, M.; Monetti, A.; Lollo, M.; Calderolla, M.; Vasquez, J.; Zafiropoulos, D.; Sarchiapone, L.; Benini, D.; Favaron, P.; Rigato, M.; Pegoraro, R.; Maniero, D.; Calabretta, L.; Comunian, M.; Maggiore, M.; Lombardi, A.; Piazza, L.; Porcellato, A. M.; Roncolato, C.; Bisoffi, G.; Pisent, A.; Galatà, A.; Giacchini, M.; Bassato, G.; Canella, S.; Gramegna, F.; Valiente, J.; Bermudez, J.; Mastinu, P. F.; Esposito, J.; Wyss, J.; Russo, A.; Zanella, S.

    2015-04-01

    A new Radioactive Ion Beam (RIB) facility (SPES) is presently under construction at the Legnaro National Laboratories of INFN. The SPES facility is based on the ISOL method using an UCx Direct Target able to sustain a power of 10 kW. The primary proton beam is provided by a high current Cyclotron accelerator with energy of 35-70 MeV and a beam current of 0.2-0.5 mA. Neutron-rich radioactive ions are produced by proton induced fission on an Uranium target at an expected fission rate of the order of 1013 fissions per second. After ionization and selection the exotic isotopes are re-accelerated by the ALPI superconducting LINAC at energies of 10A MeV for masses in the region A=130 amu. The expected secondary beam rates are of the order of 107 - 109 pps. Aim of the SPES facility is to deliver high intensity radioactive ion beams of neutron rich nuclei for nuclear physics research as well as to be an interdisciplinary research centre for radio-isotopes production for medicine and for neutron beams.

  20. Thin and thick targets for radioactive ion beam production at SPIRAL1 facility

    NASA Astrophysics Data System (ADS)

    Jardin, P.; Bajeat, O.; Delahaye, P.; Dubois, M.; Kuchi, V.; Maunoury, L.

    2018-05-01

    The upgrade of the Système de Production d'Ions Radioactifs Accélérés en Ligne (SPIRAL1) facility will deliver its new Radioactive Ion Beams (RIB) by summer 2017. The goal of the upgrade is an improvement of the performances of the installation in terms of isotopes species and ion charge states [1]. Ion beams are produced using the Isotope Separator On Line Method, consisting in an association of a primary beam of stable ions, a hot target and an ion source. The primary beam impinges on the material of the target. Radioactive isotopes are produced by nuclear reactions and propagate up to the source, where they are ionized and accelerated to create a RIB. One advantage of SPIRAL1 driver is the variety of its available primary beams, from carbon to uranium with energies up to 95 MeV/A. Within the SPIRAL1 upgrade, they will be combined with targets made of a large choice of materials, extending in this way the number of possible nuclear reactions (fusion-evaporation, transfer, fragmentation) for producing a wider range of isotopes, up to regions of the nuclide chart still scarcely explored. Depending on the reaction process, on the collision energy and on the primary beam power, thin and thick targets are used. As their functions can be different, their design must cope with specific constraints which will be described. After a presentation of the goals of present and future SPIRAL1 Target Ion Source System, the main target features, studies and designs under progress are presented.

  1. Computational design of high efficiency release targets for use at ISOL facilities

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Alton, G. D.; Middleton, J. W.

    1999-06-01

    This report describes efforts made at the Oak Ridge National Laboratory to design high-efficiency-release targets that simultaneously incorporate the short diffusion lengths, high permeabilities, controllable temperatures, and heat removal properties required for the generation of useful radioactive ion beam (RIB) intensities for nuclear physics and astrophysics research using the isotope separation on-line (ISOL) technique. Short diffusion lengths are achieved either by using thin fibrous target materials or by coating thin layers of selected target material onto low-density carbon fibers such as reticulated vitreous carbon fiber (RVCF) or carbon-bonded-carbon-fiber (CBCF) to form highly permeable composite target matrices. Computational studies which simulate the generation and removal of primary beam deposited heat from target materials have been conducted to optimize the design of target/heat-sink systems for generating RIBs. The results derived from diffusion release-rate simulation studies for selected targets and thermal analyses of temperature distributions within a prototype target/heat-sink system subjected to primary ion beam irradiation will be presented in this report.

  2. High-efficiency-release targets for use at ISOL facilities: computational design

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Alton, G. D.

    1999-12-01

    This report describes efforts made at the Oak Ridge National Laboratory to design high-efficiency-release targets that simultaneously incorporate the short diffusion lengths, high permeabilities, controllable temperatures, and heat-removal properties required for the generation of useful radioactive ion beam (RIB) intensities for nuclear physics and astrophysics research using the isotope separation on-line (ISOL) technique. Short diffusion lengths are achieved either by using thin fibrous target materials or by coating thin layers of selected target material onto low-density carbon fibers such as reticulated-vitreous-carbon fiber (RVCF) or carbon-bonded-carbon fiber (CBCF) to form highly permeable composite target matrices. Computational studies that simulate the generation and removal of primary beam deposited heat from target materials have been conducted to optimize the design of target/heat-sink systems for generating RIBs. The results derived from diffusion release-rate simulation studies for selected targets and thermal analyses of temperature distributions within a prototype target/heat-sink system subjected to primary ion beam irradiation are presented in this report.

  3. Targets used in the production of radioactive ion beams at the HRIBF

    NASA Astrophysics Data System (ADS)

    Stracener, D. W.; Alton, G. D.; Auble, R. L.; Beene, J. R.; Mueller, P. E.; Bilheux, J. C.

    2004-03-01

    Radioactive ion beams are produced at the Holifield Radioactive Ion Beam Facility using the Isotope Separation On-Line (ISOL) technique where the atoms are produced in a thick target, transported to an ion source, ionized, and extracted from the ion source to form an ion beam. These radioactive ion beams are then accelerated to energies of a few MeV per nucleon and delivered to experimental stations for use in nuclear physics and nuclear astrophysics experiments. At the heart of this facility is the RIB production target, where the radioactive nuclei are produced using beams of light ions (p, d, 3He, α) to induce nuclear reactions in the target nuclei. Several target materials have been developed and used successfully, including Al 2O 3, HfO 2, SiC, CeS, liquid Ge, liquid Ni, and a low-density matrix of uranium carbide. The details of these targets and some of the target developments that led to the delivery of high-quality radioactive ion beams are discussed in this paper.

  4. Thermal-electric numerical simulation of a surface ion source for the production of radioactive ion beams

    NASA Astrophysics Data System (ADS)

    Manzolaro, Mattia; Meneghetti, Giovanni; Andrighetto, Alberto

    2010-11-01

    In a facility for the production of radioactive ion beams (RIBs), the target system and the ion source are the most critical objects. In the context of the Selective Production of Exotic Species (SPES) project, a proton beam directly impinges a Uranium Carbide production target, generating approximately 10 13 fissions per second. The radioactive isotopes produced by the 238U fissions are then directed to the ion source to acquire a charge state. After that, the radioactive ions obtained are transported electrostatically to the subsequent areas of the facility. In this work the surface ion source at present adopted for the SPES project is studied by means of both analytical and numerical thermal-electric models. The theoretical results are compared with temperature and electric potential difference measurements.

  5. A study of general instability of box beams with truss-type ribs

    NASA Technical Reports Server (NTRS)

    Lundquist, Eugene E; Schwartz, Edward B

    1942-01-01

    The design of truss-type ribs for box beams is theoretically treated with regard to the function of the ribs in stabilizing the compression flange. The theory is applied to a design problem, and the results of this application are presented and discussed in relation to the general problem of rib design. The results of some tests made as a part of this general study are presented in an appendix.

  6. Physics with heavy neutron-rich RIBs at the HRIBF

    NASA Astrophysics Data System (ADS)

    Radford, D. C.; Baktash, C.; Galindo-Uribarri, A.; Gross, C. J.; Lewis, T. A.; Mueller, P. E.; Hausladen, P. A.; Shapira, D.; Stracener, D. W.; Yu, C.-H.; Fuentes, B.; Padilla, E.; Hartley, D. J.; Barton, C. J.; Caprio, M.; Zamfir, N. V.

    The Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory has recently produced the world's first post-accelerated beams of heavy neutron-rich nuclei. The first experiments with these beam are described, and the results discussed. B(E2;0+ --> 2+) values for neutron-rich 126,128Sn and 132,134,136Te isotopes have been measured by Coulomb excitation in inverse kinematics. The results for 132Te and 134Te (N = 80, 82) show excellent agreement with systematics of lighter Te isotopes, but the B(E2) value for 136Te (N = 84) is unexpectedly small. Single-neutron transfer reactions with a 134Te beam on natBe and 13C targets at energies just above the Coulomb barrier have also been studied.

  7. 8B + 208Pb Elastic Scattering at Coulomb Barrier Energies

    NASA Astrophysics Data System (ADS)

    La Commara, M.; Mazzocco, M.; Boiano, A.; Boiano, C.; Manea, C.; Parascandolo, C.; Pierroutsakou, D.; Signorini, C.; Strano, E.; Torresi, D.; Yamaguchi, H.; Kahl, D.; Di Meo, P.; Grebosz, J.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Iwasa, N.; Jeong, S. C.; Jia, H. M.; Kim, Y. H.; Kimura, S.; Kubono, S.; Lin, C. J.; Miyatake, H.; Mukai, M.; Nakao, T.; Nicoletto, M.; Sakaguchi, Y.; Sánchez-Benítez, A. M.; Soramel, F.; Teranishi, T.; Wakabayashi, Y.; Watanabe, Y. X.; Yang, L.; Yang, Y. Y.

    2018-02-01

    The scattering process of weakly-bound nuclei at Coulomb barrier energies provides deep insights on the reaction dynamics induced by exotic nuclei. Within this framework, we measured for the first time the scattering process of the short-lived Radioactive Ion Beam (RIB) 8B (Sp = 0.1375 MeV) from a 208Pb target at 50 MeV beam energy. The 8B RIB was produced by means of the in-flight facility CRIB (RIKEN, Japan) with an average intensity on target of 10 kHz and a purity about 25%. Elastically scattering ions were detected in the angular range θc.m. = 10°-160° by means of the detector array EXPADES. A preliminary optical model analysis indicates a total reaction cross section of about 1 b, a value, once reduced, 2-3 times larger than those obtained for the reactions induced by the stable weakly-bound projectiles 6,7Li on a 208Pb target in the energy range around the Coulomb barrier.

  8. 8B + 208Pb Elastic Scattering at Coulomb Barrier Energies

    NASA Astrophysics Data System (ADS)

    La Commara, M.; Mazzocco, M.; Boiano, A.; Boiano, C.; Manea, C.; Parascandolo, C.; Pierroutsakou, D.; Signorini, C.; Strano, E.; Torresi, D.; Yamaguchi, H.; Kahl, D.; Di Meo, P.; Grebosz, J.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Iwasa, N.; Jeong, S. C.; Jia, H. M.; Kim, Y. H.; Kimura, S.; Kubono, S.; Lin, C. J.; Miyatake, H.; Mukai, M.; Nakao, T.; Nicoletto, M.; Sakaguchi, Y.; Sánchez-Benítez, A. M.; Soramel, F.; Teranishi, T.; Wakabayashi, Y.; Watanabe, Y. X.; Yang, L.; Yang, Y. Y.

    2017-11-01

    The scattering process of weakly-bound nuclei at Coulomb barrier energies provides deep insights on the reaction dynamics induced by exotic nuclei. Within this framework, we measured for the first time the scattering process of the short-lived Radioactive Ion Beam (RIB) 8B (S p = 0.1375 MeV) from a 208Pb target at 50 MeV beam energy. The 8B RIB was produced by means of the in-flight facility CRIB (RIKEN, Japan) with an average intensity on target of 10 kHz and a purity about 25%. Elastically scattering ions were detected in the angular range θc.m. = 10°-160° by means of the detector array EXPADES. A preliminary optical model analysis indicates a total reaction cross section of about 1 b, a value, once reduced, 2-3 times larger than those obtained for the reactions induced by the stable weakly-bound projectiles 6,7Li on a 208Pb target in the energy range around the Coulomb barrier.

  9. The SPES High Power ISOL production target

    NASA Astrophysics Data System (ADS)

    Andrighetto, A.; Corradetti, S.; Ballan, M.; Borgna, F.; Manzolaro, M.; Scarpa, D.; Monetti, A.; Rossignoli, M.; Silingardi, R.; Mozzi, A.; Vivian, G.; Boratto, E.; De Ruvo, L.; Sattin, N.; Meneghetti, G.; Oboe, R.; Guerzoni, M.; Margotti, A.; Ferrari, M.; Zenoni, A.; Prete, G.

    2016-11-01

    SPES (Selective Production of Exotic Species) is a facility under construction at INFN-LNL (Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Legnaro), aimed to produce intense neutron-rich radioactive ion beams (RIBs). These will be obtained using the ISOL (Isotope Separation On-Line) method, bombarding a uranium carbide target with a proton beam of 40MeV energy and currents up to 200μA. The target configuration was designed to obtain a high number of fissions, up to 1013 per second, low power deposition and fast release of the produced isotopes. The exotic isotopes generated in the target are ionized, mass separated and re-accelerated by the ALPI superconducting LINAC at energies of 10AMeV and higher, for masses in the region of A = 130 amu , with an expected rate on the secondary target up to 109 particles per second. In this work, recent results on the R&D activities regarding the SPES RIB production target-ion source system are reported.

  10. Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greef, M. de, E-mail: m.degreef@umcutrecht.nl; Wijlemans, J. W.; Bartels, L. W.

    2015-08-15

    Purpose: One of the major issues in high intensity focused ultrasound ablation of abdominal lesions is obstruction of the ultrasound beam by the thoracic cage. Beam shaping strategies have been shown by several authors to increase focal point intensity while limiting rib exposure. However, as rib obstruction leaves only part of the aperture available for energy transmission, conserving total emitted acoustic power, the intensity in the near-field tissues inherently increases after beam shaping. Despite of effective rib sparing, those tissues are therefore subjected to increased risk of thermal damage. In this study, for a number of clinically representative intercostal sonicationmore » geometries, modeling clinically available hardware, the effect of beam shaping on both the exposure of the ribs and near-field to acoustic energy was evaluated and the implications for the volumetric ablation rate were addressed. Methods: A relationship between rib temperature rise and acoustic energy density was established by means of in vivo MR thermometry and simulations of the incident acoustic energy for the corresponding anatomies. This relationship was used for interpretation of rib exposure in subsequent numerical simulations in which rib spacing, focal point placement, and the focal point trajectory were varied. The time required to heat a targeted region to 65 °C was determined without and with the application of beam shaping. The required sonication time was used to calculate the acoustic energy density at the fat–muscle interface and at the surface of the ribs. At the fat–muscle interface, exposure was compared to available literature data and rib exposure was interpreted based on the earlier obtained relation between measured temperature rise and simulated acoustic energy density. To estimate the volumetric ablation rate, the cool-down time between periods of energy exposure was estimated using a time-averaged power limit of 100 kJ/h. Results: At the level of the ribs, the temperature rise–energy density proportionality constant was estimated to be 6.0–7.6 °C/(J/mm{sup 2}). Beam shaping by the geometric shadow method typically reduces the acoustic intensity a factor of 2, considering the 1 cm{sup 2} with the highest exposure. For a 4 mm diameter circular sonication trajectory, the near-field energy limit of 2.5 J/mm{sup 2} was exceeded for all considered geometries. The estimated rib temperature was in all but one (sonication 50 mm behind the ribs, with 15 mm rib spacing and a 4 mm diameter circular sonication trajectory) of the considered scenarios within acceptable limits. For those sonication scenarios where a single sonication is considered safe both in terms of near-field as well as rib heating, volumetric ablation rates in the order of 1 ml/h are estimated. Conclusions: Intercostal sonication is associated with an increased risk of near-field overheating. This risk is strongly dependent on the considered rib spacing, the placement of the focus behind the ribs, and the selected sonication trajectory. For the hardware under simulation, obstruction by the thoracic cage renders ablations of clinically relevant volumes within a practical time-frame unfeasible in a large part of the liver. Improvements maybe expected from transducer designs with a larger active surface and/or nonlinear sonication strategies.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, D; Sood, S; Badkul, R

    Purpose: To evaluate XVMC computed rib doses for peripherally located non-small-cell-lung tumors treated with SBRT following RTOG-0915 guidelines. Methods: Twenty patients with solitary peripherally located non-small-cell-lung tumors were treated using XVMC-based SBRT to 50–54Gy in 5−3 fractions, respectively, for PTV(V100%)=95%. Based on 4D-CT, ITV was delineated on MaximumIP images and organs-at-risk(OARs) including ribs were contoured on MeanIP images. Mean PTV(ITV+5mm uniform margin) was 46.1±38.7cc (range, 11.1–163.0cc). XVMC SBRT treatment plans were generated with a combination of non-coplanar 3D-conformal arcs/beams, and were delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000MU/min) beam, following RTOG-0915 criteria. XVMC rib maximum dose and dosemore » to <1cc, <5cc, <10cc were evaluated as a function of PTV, prescription dose and 3D-distance from tumor isocenter to the most proximal rib contour. Plans were re-computed using heterogeneity-corrected pencil-beam (PB-hete) algorithm utilizing identical beam geometry/MLC positions and MUs and subsequently compared to XVMC. Results: XVMC average maximum rib dose was 50.9±6.4Gy (range, 35.1–59.3Gy). XVMC mean rib dose to <1cc was 41.6±5.6Gy (range, 27.9–47.9Gy), <5cc was 31.2±7.3Gy (range, 10.6–43.1Gy), and <10cc was 21.2±8.7Gy (range, 1.1–36Gy), respectively. For the given prescription, correlation between PTV and rib doses to <5cc (p=0.005) and <10cc (p=0.018) was observed. 3D-distance from the tumor isocenter to the proximal rib contour strongly correlated with maximum rib dose (p=0.0001). PB-hete algorithm overestimated maximum rib dose and dose to <1cc, <5cc, and <10cc of ribs by 5%, 3%, 3%, and 3%, respectively. Conclusion: PB-hete overestimates ribs dose relative to XVMC. Since all the clinical XVMC plans were generated without compromising the target coverage (per RTOG-0915), almost all patient’s ribs doses were higher than the protocol guidelines. As expected, larger tumor size and proximity to ribs received higher absolute dose to ribs. Prospective observation is needed to determine if XVMC delivered rib doses correlates with patient symptoms including chest wall pain and/or rib fractures.« less

  12. Optimizing charge breeding techniques for ISOL facilities in Europe: Conclusions from the EMILIE project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delahaye, P., E-mail: delahaye@ganil.fr; Jardin, P.; Maunoury, L.

    The present paper summarizes the results obtained from the past few years in the framework of the Enhanced Multi-Ionization of short-Lived Isotopes for Eurisol (EMILIE) project. The EMILIE project aims at improving the charge breeding techniques with both Electron Cyclotron Resonance Ion Sources (ECRIS) and Electron Beam Ion Sources (EBISs) for European Radioactive Ion Beam (RIB) facilities. Within EMILIE, an original technique for debunching the beam from EBIS charge breeders is being developed, for making an optimal use of the capabilities of CW post-accelerators of the future facilities. Such a debunching technique should eventually resolve duty cycle and time structuremore » issues which presently complicate the data-acquisition of experiments. The results of the first tests of this technique are reported here. In comparison with charge breeding with an EBIS, the ECRIS technique had lower performance in efficiency and attainable charge state for metallic ion beams and also suffered from issues related to beam contamination. In recent years, improvements have been made which significantly reduce the differences between the two techniques, making ECRIS charge breeding more attractive especially for CW machines producing intense beams. Upgraded versions of the Phoenix charge breeder, originally developed by LPSC, will be used at SPES and GANIL/SPIRAL. These two charge breeders have benefited from studies undertaken within EMILIE, which are also briefly summarized here.« less

  13. SPES and the neutron facilities at Laboratori Nazionali di Legnaro

    NASA Astrophysics Data System (ADS)

    Silvestrin, L.; Bisello, D.; Esposito, J.; Mastinu, P.; Prete, G.; Wyss, J.

    2016-03-01

    The SPES Radioactive Ion Beam (RIB) facility, now in the construction phase at INFN-LNL, has the aim to provide high-intensity and high-quality beams of neutron-rich nuclei for nuclear physics research as well as to develop an interdisciplinary research center based on the cyclotron proton beam. The SPES system is based on a dual-exit high-current cyclotron, with tunable proton beam energy 35-70MeV and 0.20-0.75mA. The first exit is used as proton driver to supply an ISOL system with an UCx Direct Target able to sustain a power of 10kW. The expected fission rate in the target is of the order of 10^{13} fissions per second. The exotic isotopes will be re-accelerated by the ALPI superconducting LINAC at energies of 10 A MeV and higher, for masses around A=130 amu, with an expected beam intensity of 10^7 - 10^9 pps. The second exit will be used for applied physics: radioisotope production for medicine and neutrons for material studies. Fast neutron spectra will be produced by the proton beam interaction with a conversion target. A production rate in excess of 10^{14} n/s can be achieved: this opens up the prospect of a high-flux neutron irradiation facility (NEPIR) to produce both discrete and continuous energy neutrons. A direct proton beam line is also envisaged. NEPIR and the direct proton line would dramatically increase the wide range of irradiation facilities presently available at LNL. We also present LENOS, a proposed project dedicated to accurate neutron cross-sections measurements using intense, well-characterized, broad energy neutron beams. Other activities already in operation at LNL are briefly reviewed: the SIRAD facility for proton and heavy-ion irradiation at the TANDEM-ALPI accelerator and the BELINA test facility at CN van de Graaff accelerator.

  14. ARIEL e-LINAC: Commissioning and Development

    NASA Astrophysics Data System (ADS)

    Laxdal, R. E.; Zvyagintsev, V.

    2016-09-01

    A superconducting electron Linac (e-Linac) will be a part of the ARIEL facility for the production of radioactive ion beams (RIB) at TRIUMF. The e-Linac will consist of five 1.3GHz 9-cell cavities in three cryomodules delivering a 50MeV 10mA beam. The baseline operation will be single pass but a re-circulating ring is planned to allow either energy boost or energy recovery operation. The first stage of the accelerator which consists of two cryomodules has been successfully commissioned in 2014. The paper will discuss the superconducting radio-frequency (SRF) challenges of the accelerator. Cavities, crymodules and RF system design, preparation, and performance will be presented.

  15. Design for beam splitting components employing silicon-on-insulator rib waveguide structures.

    PubMed

    Hsiao, C S; Wang, Likarn

    2005-12-01

    We present a new design for beam splitting components employing a silicon-on-insulator rib waveguide structures. In the new design, a high-index thin-film layer is deposited in the rib section to reduce the wave field dispersive tails in the slab section and accordingly render the mode field a confined spot. This in turn improves the beam splitting performance of some conventional waveguide components such as y branches and multimode interference couplers (MMICs), in terms of the excess loss, fiber coupling loss, and compactness of these components. For a 1 x 2 y-branch beam splitter, the excess loss can be as small as 0.43 dB in the new design, which is much lower than that for a conventional rib waveguide structure (which is 1.28 dB). For a 1 x 2 MMIC in our example, the new rib waveguide structure presents an excess loss of 0.064 dB for the TE mode and 0.046 dB for the TM mode, with negligible nonuniformity in dimensions of 30 microm x 1040 microm, whereas its counterpart (i.e., the one with the same dimensions but without a thin-film layer) presents an excess loss of approximately 0.86 dB for both modes. A conventional MMIC must have dimensions larger than 70 microm x 5650 microm to maintain almost the same low excess loss.

  16. Large space deployable antenna systems

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The design technology is described for manufacturing a 20 m or larger space erectable antenna with high thermal stability, high dynamic stiffness, and minimum stowed size. The selected approach includes a wrap rib design with a cantilever beam basic element and graphite-epoxy composite lenticular cross section ribs. The rib configuration and powered type operated deploying mechanism are described and illustrated. Other features of the parabolic reflector discussed include weight and stowed diameter characteristics, structural dynamics characteristics, orbit thermal aperture limitations, and equivalent element and secondary (on axis) patterns. A block diagram of the multiple beam pattern is also presented.

  17. Development of the (d,n) Proton-transfer Reaction in Inverse Kinematics for Structure Studies

    NASA Astrophysics Data System (ADS)

    Jones, K. L.; Thornsberry, C.; Allen, J.; Atencio, A.; Bardayan, D. W.; Blankstein, D.; Burcher, S.; Carter, A. B.; Chipps, K. A.; Cizewski, J. A.; Cox, I.; Elledge, Z.; Febbraro, M.; Fijałkowska, A.; Grzywacz, R.; Hall, M. R.; King, T. T.; Lepailleur, A.; Madurga, M.; Marley, S. T.; O'Malley, P. D.; Paulauskas, S. V.; Pain, S. D.; Peters, W. A.; Reingold, C.; Smith, K.; Taylor, S.; Tan, W.; Vostinar, M.; Walter, D.

    Transfer reactions have provided exciting opportunities to study the structure of exotic nuclei and are often used to inform studies relating to nucleosynthesis and applications. In order to benefit from these reactions and their application to rare ion beams (RIBs) it is necessary to develop the tools and techniques to perform and analyze the data from reactions performed in inverse kinematics, that is with targets of light nuclei and heavier beams. We are continuing to expand the transfer reaction toolbox in preparation for the next generation of facilities, such as the Facility for Rare Ion Beams (FRIB), which is scheduled for completion in 2022. An important step in this process is to perform the (d,n) reaction in inverse kinematics, with analyses that include Q-value spectra and differential cross sections. In this way, proton-transfer reactions can be placed on the same level as the more commonly used neutron-transfer reactions, such as (d,p), (9Be,8Be), and (13C,12C). Here we present an overview of the techniques used in (d,p) and (d,n), and some recent data from (d,n) reactions in inverse kinematics using stable beams of 12C and 16O.

  18. Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: application to intercostal ablation in liver.

    PubMed

    Salomir, Rares; Petrusca, Lorena; Auboiroux, Vincent; Muller, Arnaud; Vargas, Maria-Isabel; Morel, Denis R; Goget, Thomas; Breguet, Romain; Terraz, Sylvain; Hopple, Jerry; Montet, Xavier; Becker, Christoph D; Viallon, Magalie

    2013-06-01

    The treatment of liver cancer is a major public health issue because the liver is a frequent site for both primary and secondary tumors. Rib heating represents a major obstacle for the application of extracorporeal focused ultrasound to liver ablation. Magnetic resonance (MR)-guided external shielding of acoustic obstacles (eg, the ribs) was investigated here to avoid unwanted prefocal energy deposition in the pathway of the focused ultrasound beam. Ex vivo and in vivo (7 female sheep) experiments were performed in this study. Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) was performed using a randomized 256-element phased-array transducer (f∼1 MHz) and a 3-T whole-body clinical MR scanner. A physical mask was inserted in the prefocal beam pathway, external to the body, to block the energy normally targeted on the ribs. The effectiveness of the reflecting material was investigated by characterizing the efficacy of high-intensity focused ultrasound beam reflection and scattering on its surface using Schlieren interferometry. Before high-intensity focused ultrasound sonication, the alignment of the protectors with the conical projections of the ribs was required and achieved in multiple steps using the embedded graphical tools of the MR scanner. Multiplanar near real-time MR thermometry (proton resonance frequency shift method) enabled the simultaneous visualization of the local temperature increase at the focal point and around the exposed ribs. The beam defocusing due to the shielding was evaluated from the MR acoustic radiation force impulse imaging data. Both MR thermometry (performed with hard absorber positioned behind a full-aperture blocking shield) and Schlieren interferometry indicated a very good energy barrier of the shielding material. The specific temperature contrast between rib surface (spatial average) and focus, calculated at the end point of the MRgHIFU sonication, with protectors vs no protectors, indicated an important reduction of the temperature elevation at the ribs' surface, typically by 3.3 ± 0.4 in vivo. This was translated into an exponential reduction in thermal dose by several orders of magnitude. The external shielding covering the full conical shadow of the ribs was more effective when the protectors could be placed close to the ribs' surface and had a tendency to lose its efficiency when placed further from the ribs. Hepatic parenchyma was safely ablated in vivo using this rib-sparing strategy and single-focus independent sonications. A readily available, MR-compatible, effective, and cost-competitive method for rib protection in transcostal MRgHIFU was validated in this study, using specific reflective strips. The current approach permitted safe intercostal ablation of small volumes (0.7 mL) of liver parenchyma.

  19. Elastic scattering and total reaction cross section for the 6He +58Ni system

    NASA Astrophysics Data System (ADS)

    Morcelle, V.; Lichtenthäler, R.; Lépine-Szily, A.; Guimarães, V.; Mendes, D. R., Jr.; Pires, K. C. C.; de Faria, P. N.; Barioni, A.; Gasques, L.; Morais, M. C.; Shorto, J. M. B.; Zamora, J. C.; Scarduelli, V.; Condori, R. Pampa; Leistenschneider, E.

    2014-11-01

    Elastic scattering measurements of 6He + 58Ni system have been performed at the laboratory energy of 21.7 MeV. The 6He secondary beam was produced by a transfer reaction 9Be (7Li , 6He ) and impinged on 58Ni and 197Au targets, using the Radioactive Ion Beam (RIB) facility, RIBRAS, installed in the Pelletron Laboratory of the Institute of Physics of the University of São Paulo, Brazil. The elastic angular distribution was obtained in the angular range from 15° to 80° in the center of mass frame. Optical model calculations have been performed using a hybrid potential to fit the experimental data. The total reaction cross section was derived.

  20. 12. DETAIL OF NORTH ABUTMENT, FROM BENEATH, SHOWING ARCH RIB ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. DETAIL OF NORTH ABUTMENT, FROM BENEATH, SHOWING ARCH RIB AND FLOOR BEAM. VIEW TO NORTHEAST. - Rock Valley Bridge, Spanning North Timber Creek at Old U.S. Highway 30, Marshalltown, Marshall County, IA

  1. 11. DETAIL OF WEST WEB, FROM STREAMBANK, SHOWING ARCH RIB, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. DETAIL OF WEST WEB, FROM STREAMBANK, SHOWING ARCH RIB, HANGERS, FLOOR BEAMS AND GUARDRAIL. VIEW TO NORTHEAST. - Rock Valley Bridge, Spanning North Timber Creek at Old U.S. Highway 30, Marshalltown, Marshall County, IA

  2. Compact wavelength-insensitive fabrication-tolerant silicon-on-insulator beam splitter.

    PubMed

    Rasigade, Gilles; Le Roux, Xavier; Marris-Morini, Delphine; Cassan, Eric; Vivien, Laurent

    2010-11-01

    A star coupler-based beam splitter for rib waveguides is reported. A design method is presented and applied in the case of silicon-on-insulator rib waveguides. Experimental results are in good agreement with simulations. Excess loss lower than 1 dB is experimentally obtained for star coupler lengths from 0.5 to 1 μm. Output balance is better than 1 dB, which is the measurement accuracy, and broadband transmission is obtained over 90 nm.

  3. Nuclear reactions with carbon-11 and oxygen-14 radioactive ion beams

    NASA Astrophysics Data System (ADS)

    Guo, Fanqing

    Radioactive ion beams (RIBs) have been shown to be a useful tool for studying proton-rich nuclides near and beyond the proton dripline and for evaluating nuclear models. To take full advantage of RIBs, Elastic Resonance Scattering in Inverse Kinematics with Thick Targets (ERSIKTT), has proven to be a reliable experimental tool for investigations of proton unbound nuclei. Following several years of effort, Berkeley Experiments with Accelerated Radioactive Species (BEARS), a RIBs capability, has been developed at the Lawrence Berkeley National Laboratory's 88-Inch Cyclotron. The current BEARS provides two RIBs: a 11C beam of up to 2 x 10 8 pps intensity on target and an 14O beam of up to 3 x 104 pps intensity. While the development of the 11C beam has been relatively easy, a number of challenges had to be overcome to obtain the 14O beam. The excellent 11C beam has been used to investigate several reactions. The first was the 197Au(11C,xn) 208-xnAt reaction, which was used to measure excitation functions for the 4n to 8n exit channels. The measured cross sections were generally predicted quite well using the fusion-evaporation code HIVAP. Possible errors in the branching ratios of alpha decays from At isotopes as well as the presence of incomplete fusion reactions probably contribute to specific overpredictions. 15F has been investigated by the p(14O,p) 14O reaction with the ERSIKTT technology. Several 14O+p runs have been performed. Excellent energy calibration was obtained using resonances from the p(14N,p)14N reaction in inverse kinematics, and comparing the results to those obtained earlier with normal kinematics. The differences between 14N+p and 14O+p in the stopping power function have been evaluated for better energy calibration. After careful calibration, the energy levels of 15F were fitted with an R-matrix calculation. Spins and parities were assigned to the two observed resonances. This new measurement of the 15F ground state supports the disappearance of the Z = 8 proton magic number for odd Z, Tz = -3/2 nuclei. It is expected that future work on proton-rich nuclides will rely heavily on RIBs and/or mass separators. Currently, radioactive ion beam intensities are sufficient for the study of a reasonable number of very proton-rich nuclides.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Elsayed

    Purpose: To characterize and correct for radiation-induced background (RIB) observed in the signals from a class of scanning water tanks. Methods: A method was developed to isolate the RIB through detector measurements in the background-free linac console area. Variation of the RIB against a large number of parameters was characterized, and its impact on basic clinical data for photon and electron beams was quantified. Different methods to minimize and/or correct for the RIB were proposed and evaluated. Results: The RIB is due to the presence of the electrometer and connection box in a low background radiation field (by design). Themore » absolute RIB current with a biased detector is up to 2 pA, independent of the detector size, which is 0.6% and 1.5% of the central axis reference signal for a standard and a mini scanning chamber, respectively. The RIB monotonically increases with field size, is three times smaller for detectors that do not require a bias (e.g., diodes), is up to 80% larger for positive (versus negative) polarity, decreases with increasing photon energy, exhibits a single curve versus dose rate at the electrometer location, and is negligible for electron beams. Data after the proposed field-size correction method agree with point measurements from an independent system to within a few tenth of a percent for output factor, head scatter, depth dose at depth, and out-of-field profile dose. Manufacturer recommendations for electrometer placement are insufficient and sometimes incorrect. Conclusions: RIB in scanning water tanks can have a non-negligible effect on dosimetric data.« less

  5. The Radioactive Ion Beams in Brazil (RIBRAS) facility. Description, program, main results, future plans

    NASA Astrophysics Data System (ADS)

    Lépine-Szily, A.; Lichtenthäler, R.; Guimarães, V.

    2014-08-01

    RIBRAS (Radioactive Ion Beams in Brazil) is a facility installed at the Institute of Physics of the University of São Paulo (IFUSP), Brazil. The RIBRAS system consists of two superconducting solenoids and uses the "in-flight method" to produce radioactive ion beams using the primary beam provided by the 8UD Pelletron Tandem of IFUSP. The ion beams produced so far by RIBRAS are 6He, 8Li, 7Be, 10Be, 8B, 12B with intensities that can vary from 104 to 106 pps. Initially the experimental program covered the study of elastic and inelastic scattering with the objective to study the interaction potential and the reaction mechanisms between weakly bound (RIB) and halo (6He and 8B projectiles on light, medium and heavy mass targets. With highly purified beams, the study of resonant elastic scattering and resonant transfer reactions, using inverse kinematics and thick targets, has also been included in our experimental program. Also, transfer reactions of astrophysical interest and fusion reactions induced by halo nuclei are part of the near-future research program. Our recent results on elastic scattering, alpha-particle production and total reaction cross sections, as well as the resonant elastic and transfer reactions, are presented. Our plans for the near future are related to the installation of a new beam line and a cave for gamma-ray detection. We intend to place in operation a large area neutron detector available in our laboratory. The long-range plans could be the move of the RIBRAS system to the more energetic beam line of the LINAC post-accelerator (10MeV/nucleon primary beams) still in construction in our laboratory.

  6. Joining and reinforcing a composite bumper beam and a composite crush can for a vehicle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berger, Elisabeth; Decker, Leland; Armstrong, Dale

    A front bumper beam and crush can (FBCC) system is provided for a vehicle. A bumper beam has an interior surface with a plurality of ribs extending therefrom. The ribs and the interior surface are made of a chopped fiber composite and cooperate to engage a crush can. The chopped fiber composite reinforces the engaging surfaces of the crush can and the interior surface of the bumper beam. The crush can has a tubular body made of a continuous fiber composite. The crush can has outwardly-extending flanges at an end spaced away from the bumper beam. The flanges are atmore » least partially provided with a layer of chopped fiber composite to reinforce a joint between the outwardly-extending flange and the vehicle frame.« less

  7. Elastic scattering and total reaction cross section for the {sup 6}He+{sup 58}Ni system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morcelle, V.; Lichtenthäler, R.; Lépine-Szily, A.

    2014-11-11

    Elastic scattering measurements of {sup 6}He + {sup 58}Ni system have been performed at the laboratory energy of 21.7 MeV. The {sup 6}He secondary beam was produced by a transfer reaction {sup 9}Be ({sup 7}Li, {sup 6}He) and impinged on {sup 58}Ni and {sup 197}Au targets, using the Radioactive Ion Beam (RIB) facility, RIBRAS, installed in the Pelletron Laboratory of the Institute of Physics of the University of São Paulo, Brazil. The elastic angular distribution was obtained in the angular range from 15° to 80° in the center of mass frame. Optical model calculations have been performed using a hybridmore » potential to fit the experimental data. The total reaction cross section was derived.« less

  8. Understanding Release from Actinide Targets -- Recent Results from RIB Development

    NASA Astrophysics Data System (ADS)

    Kronenberg, Andreas; Carter, H. K.; Spejewski, E. H.; Stracener, D. W.

    2006-10-01

    Development of ion beams of short-lived isotopes is crucial for modern nuclear structure and nuclear astrophysics. The Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory uses the ISOL (Isotope Separation Online) technique to provide radioactive ion beams. So far, uranium carbide has been used as a target to produce neutron-rich fission fragments. Thermodynamic calculations indicate the possibility of in-situ chemical side band formations of volatile species of refractory metals, such as V and Re. These elements release out of oxide targets after production in a nuclear reaction, and can occur only through in-situ formation of their volatile oxide. These have been confirmed experimentally. The results from recent, more detailed investigations of ThO2, UB4 and other actinide targets as well as conclusions from systematic studies will be presented. This research was sponsored by the NNSA under Stewardship Science Academic Alliance program through DOE Cooperative Agreement # DE-FC03-3NA00143.

  9. The design of the Spectrometer Ring at the HIAF

    NASA Astrophysics Data System (ADS)

    Wu, B.; Yang, J. C.; Xia, J. W.; Yan, X. L.; Hu, X. J.; Mao, L. J.; Sheng, L. N.; Wu, J. X.; Yin, D. Y.; Chai, W. P.; Shen, G. D.; Ge, W. W.; Wang, G.; Zhao, H.; Ruan, S.; Ma, X. W.; Wang, M.; Litvinov, S.; Wen, W. Q.; Chen, X. C.; Chen, R. J.; Tang, M. T.; Wu, W.; Luo, C.; Zhao, T. C.; Shi, C. F.; Fu, X.; Liu, J.; Liang, L.

    2018-02-01

    The Spectrometer Ring (SRing) is an essential part of the High Intensity heavy-ion Accelerator Facility project (HIAF) in China. It is designed as a multi-functional experimental storage ring, which will be able to operate in three ion optical operation modes. The SRing will be used as a time-of-flight mass spectrometer for short-lived, especially neutron-rich nuclei. It will also be used to collect and cool Rare Isotope Beams (RIBs) or highly-charged stable ion beams for nuclear and atomic physics experiments. The design magnetic rigidity is in the range 1.5 to 15 Tm. The beam cooling system consists of stochastic cooling and electron cooling devices. With a help of an electron cooler, stored ions will be decelerated to a minimum energy of 30 MeV/u by RF cavities. The extraction system of the SRing will allow cooled ion beams to be extracted to an external target for further ion manipulations or reaction experiments. The general ion optics design and technical requirements of SRing subsystems are presented and discussed in this paper.

  10. Nuclear reactions with 11C and 14O radioactive ion beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Fanqing

    2004-01-01

    Radioactive ion beams (RIBs) have been shown to be a useful tool for studying proton-rich nuclides near and beyond the proton dripline and for evaluating nuclear models. To take full advantage of RIBs, Elastic Resonance Scattering in Inverse Kinematics with Thick Targets (ERSIKTT), has proven to be a reliable experimental tool for investigations of proton unbound nuclei. Following several years of effort, Berkeley Experiments with Accelerated Radioactive Species (BEARS), a RIBs capability, has been developed at the Lawrence Berkeley National Laboratory's 88-Inch Cyclotron. The current BEARS provides two RIBs: a 11C beam of up to 2x10 8 pps intensity onmore » target and an 14O beam of up to 3x10 4 pps intensity. While the development of the 11C beam has been relatively easy, a number of challenges had to be overcome to obtain the 14O beam. The excellent 11C beam has been used to investigate several reactions. The first was the 197Au( 11C,xn) 208-xnAt reaction, which was used to measure excitation functions for the 4n to 8n exit channels. The measured cross sections were generally predicted quite well using the fusion-evaporation code HIVAP. Possible errors in the branching ratios of ?? decays from At isotopes as well as the presence of incomplete fusion reactions probably contribute to specific overpredictions. 15F has been investigated by the p( 14O,p)14O reaction with the ERSIKTT technology. Several 14O+p runs have been performed. Excellent energy calibration was obtained using resonances from the p( 14N,p) 14N reaction in inverse kinematics, and comparing the results to those obtained earlier with normal kinematics. The differences between 14N+p and 14O+p in the stopping power function have been evaluated for better energy calibration. After careful calibration, the energy levels of 15F were fitted with an R-matrix calculation. Spins and parities were assigned to the two observed resonances. This new measurement of the 15F ground state supports the disappearance of the Z = 8 proton magic number for odd Z, T z=-3/2 nuclei. It is expected that future work on proton-rich nuclides will rely heavily on RIBs and/or mass separators. Currently, radioactive ion beam intensities are sufficient for the study of a reasonable number of very proton-rich nuclides.« less

  11. Recent charge-breeding developments with EBIS/T devices (invited).

    PubMed

    Schwarz, S; Lapierre, A

    2016-02-01

    Short breeding times, narrow charge state distributions, low background, high efficiency, and the flexible time structure of the ejected low-emittance ion pulses are among the most attractive features of electron beam ion source or trap (EBIS/T) based charge breeders. Significant progress has been made to further improve these properties: Several groups are working to increase current densities towards 10(3) or even 10(4) A/cm(2). These current densities will become necessary to deliver high charge states of heavy nuclei in a short time and/or provide sufficient space-charge capacity to handle high-current ion beams in next-generation rare-isotope beam (RIB) facilities. Efficient capture of continuous beams, attractive because of its potential of handling highest-current ion beams, has become possible with the development of high-density electron beams of >1 A. Requests for the time structure of the charge bred ion pulse range from ultra-short pulses to quasi-continuous beams. Progress is being made on both ends of this spectrum, by either dividing the extracted charge in many pulse-lets, adjusting the extraction potential for a near-uniform long pulse, or adding dedicated devices to spread the ion bunches delivered from the EBIS/T in time. Advances in EBIS/T charge state breeding are summarized, including recent results with NSCL's ReA EBIS/T charge breeder.

  12. Recent charge-breeding developments with EBIS/T devices (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwarz, S., E-mail: schwarz@nscl.msu.edu; Lapierre, A.

    Short breeding times, narrow charge state distributions, low background, high efficiency, and the flexible time structure of the ejected low-emittance ion pulses are among the most attractive features of electron beam ion source or trap (EBIS/T) based charge breeders. Significant progress has been made to further improve these properties: Several groups are working to increase current densities towards 10{sup 3} or even 10{sup 4} A/cm{sup 2}. These current densities will become necessary to deliver high charge states of heavy nuclei in a short time and/or provide sufficient space-charge capacity to handle high-current ion beams in next-generation rare-isotope beam (RIB) facilities.more » Efficient capture of continuous beams, attractive because of its potential of handling highest-current ion beams, has become possible with the development of high-density electron beams of >1 A. Requests for the time structure of the charge bred ion pulse range from ultra-short pulses to quasi-continuous beams. Progress is being made on both ends of this spectrum, by either dividing the extracted charge in many pulse-lets, adjusting the extraction potential for a near-uniform long pulse, or adding dedicated devices to spread the ion bunches delivered from the EBIS/T in time. Advances in EBIS/T charge state breeding are summarized, including recent results with NSCL’s ReA EBIS/T charge breeder.« less

  13. Behavior of sandwich panels subjected to bending fatigue, axial compression loading and in-plane bending

    NASA Astrophysics Data System (ADS)

    Mathieson, Haley Aaron

    This thesis investigates experimentally and analytically the structural performance of sandwich panels composed of glass fibre reinforced polymer (GFRP) skins and a soft polyurethane foam core, with or without thin GFRP ribs connecting skins. The study includes three main components: (a) out-of-plane bending fatigue, (b) axial compression loading, and (c) in-plane bending of sandwich beams. Fatigue studies included 28 specimens and looked into establishing service life (S-N) curves of sandwich panels without ribs, governed by soft core shear failure and also ribbed panels governed by failure at the rib-skin junction. Additionally, the study compared fatigue life curves of sandwich panels loaded under fully reversed bending conditions (R=-1) with panels cyclically loaded in one direction only (R=0) and established the stiffness degradation characteristics throughout their fatigue life. Mathematical models expressing fatigue life and stiffness degradation curves were calibrated and expanded forms for various loading ratios were developed. Approximate fatigue thresholds of 37% and 23% were determined for non-ribbed panels loaded at R=0 and -1, respectively. Digital imaging techniques showed significant shear contribution significantly (90%) to deflections if no ribs used. Axial loading work included 51 specimens and examined the behavior of panels of various lengths (slenderness ratios), skin thicknesses, and also panels of similar length with various rib configurations. Observed failure modes governing were global buckling, skin wrinkling or skin crushing. In-plane bending involved testing 18 sandwich beams of various shear span-to-depth ratios and skin thicknesses, which failed by skin wrinkling at the compression side. The analytical modeling components of axially loaded panels include; a simple design-oriented analytical failure model and a robust non-linear model capable of predicting the full load-displacement response of axially loaded slender sandwich panels, accounting for P-Delta effects, inherent out-of-straightness profile of any shape at initial conditions, and the excessive shear deformation of soft core and its effect on buckling capacity. Another model was developed to predict the load-deflection response and failure modes of in-plane loaded sandwich beams. After successful verification of the models using experimental results, comprehensive parametric studies were carried out using these models to cover parameters beyond the limitations of the experimental program.

  14. Radiological Protection and Nuclear Engineering Studies in Multi-MW Target Systems

    NASA Astrophysics Data System (ADS)

    Luis, Raul Fernandes

    Several innovative projects involving nuclear technology have emerged around the world in recent years, for applications such as spallation neutron sources, accelerator-driven systems for the transmutation of nuclear waste and radioactive ion beam (RIB) production. While the available neutron Wuxes from nuclear reactors did not increase substantially in intensity over the past three decades, the intensities of neutron sources produced in spallation targets have increased steadily, and should continue to do so during the 21st century. Innovative projects like ESS, MYRRHA and EURISOL lie at the forefront of the ongoing pursuit for increasingly bright neutron sources; driven by proton beams with energies up to 2 GeV and intensities up to several mA, the construction of their proposed facilities involves complex Nuclear Technology and Radiological Protection design studies executed by multidisciplinary teams of scientists and engineers from diUerent branches of Science. The intense neutron Wuxes foreseen for those facilities can be used in several scientiVc research Velds, such as Nuclear Physics and Astrophysics, Medicine and Materials Science. In this work, the target systems of two facilitites for the production of RIBs using the Isotope Separation On-Line (ISOL) method were studied in detail: ISOLDE, operating at CERN since 1967, and EURISOL, the next-generation ISOL facility to be built in Europe. For the EURISOL multi-MW target station, a detailed study of Radiological Protection was carried out using the Monte Carlo code FLUKA. Simulations were done to assess neutron Wuences, Vssion rates, ambient dose equivalent rates during operation and after shutdown and the production of radioactive nuclei in the targets and surrounding materials. DiUerent materials were discussed for diUerent components of the target system, aiming at improving its neutronics performance while keeping the residual activities resulting from material activation as low as possible. The second goal of this work was to perform an optimisation study for the ISOLDE neutron converter and Vssion target system. The target system was simulated using FLUKA and the cross section codes TALYS and ABRABLA, with the objective of maximising the performance of the system for the production of pure beams of neutron-rich isotopes, suppressing the contaminations by undesired neutron-deficient isobars. Two alternative target systems were proposed in the optimisation studies; the simplest of the two, with some modiVcations, was built as a prototype and tested at ISOLDE. The experimental results clearly show that it is possible, with simple changes in the layouts of the target systems, to produce purer beams of neutron-rich isotopes around the doubly magic nuclei 78Ni and 132Sn. A study of Radiological Protection was also performed, comparing the performances of the prototype target system and the standard ISOLDE target system. None

  15. Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure.

    PubMed

    Kim, Sang-Hyo; Kim, Kun-Soo; Lee, Do-Hoon; Park, Jun-Seung; Han, Oneil

    2017-11-22

    Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.

  16. Large-core single-mode rib SU8 waveguide using solvent-assisted microcontact molding.

    PubMed

    Huang, Cheng-Sheng; Wang, Wei-Chih

    2008-09-01

    This paper describes a novel fabrication technique for constructing a polymer-based large-core single-mode rib waveguide. A negative tone SU8 photoresist with a high optical transmission over a large wavelength range and stable mechanical properties was used as a waveguide material. A waveguide was constructed by using a polydimethylsiloxane stamp combined with a solvent-assisted microcontact molding technique. The effects on the final pattern's geometry of four different process conditions were investigated. Optical simulations were performed using beam propagation method software. Single-mode beam propagation was observed at the output of the simulated waveguide as well as the actual waveguide through the microscope image.

  17. Charge breeding simulations for radioactive ion beam production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Variale, V.; Raino, A. C.; Clauser, T.

    2012-02-15

    The charge breeding technique is used for radioactive ion beam (RIB) production in order of optimizing the re-acceleration of the radioactive element ions produced by a primary beam in a thick target. Charge breeding is achieved by means of a device capable of increasing the ion charge state from 1+ to a desired value n+. In order to get high intensity RIB, experiments with charge breeding of very high efficiency could be required. To reach this goal, the charge breeding simulation could help to optimize the high charge state production efficiency by finding more proper parameters for the radioactive 1+more » ions. In this paper a device based on an electron beam ion source (EBIS) is considered. In order to study that problem, a code already developed for studying the ion selective containment in an EBIS with RF quadrupoles, BRICTEST, has been modified to simulate the ion charge state breeding rate for different 1+ ion injection conditions. Particularly, the charge breeding simulations for an EBIS with a hollow electron beam have been studied.« less

  18. Effects of mean flow on transmission loss of orthogonally rib-stiffened aeroelastic plates.

    PubMed

    Xin, F X; Lu, T J

    2013-06-01

    This paper investigates the sound transmission loss (STL) of aeroelastic plates reinforced by two sets of orthogonal rib-stiffeners in the presence of external mean flow. Built upon the periodicity of the structure, a comprehensive theoretical model is developed by considering the convection effect of mean flow. The rib-stiffeners are modeled by employing the Bernoulli-Euler beam theory and the torsional wave equation. While the solution for the transmission loss of the structure based on plate displacement and acoustic pressures is given in the form of space-harmonic series, the corresponding coefficients are obtained from the solution of a system of linear equations derived from the plate-beam coupling vibration governing equation and Helmholtz equation. The model predictions are validated by comparing with existing theoretical and experimental results in the absence of mean flow. A parametric study is subsequently performed to quantify the effects of mean flow as well as structure geometrical parameters upon the transmission loss. It is demonstrated that the transmission loss of periodically rib-stiffened structure is increased significantly with increasing Mach number of mean flow over a wide frequency range. The STL value for the case of sound wave incident downstream is pronouncedly larger than that associated with sound wave incident upstream.

  19. Increased clutter level in echocardiography due to specular reflection

    NASA Astrophysics Data System (ADS)

    Fatemi, Ali; Torp, Hans; Aakhus, Svend; Rodriguez-Molares, Alfonso

    2017-03-01

    State-of-the-art echocardiography allows to correctly diagnose most of cardiovascular diseases. An unknown source of clutter, however, hinders the visualization of the heart in some cases. We believe this clutter is caused by the ultrasound beam being partially reflected by the ribs into the elevation direction, so that structures outside the imaging plane are displayed on top of the heart image as clutter noise. We conducted in vitro experiments in a water tank using a synthetic ventricle and pig ribs. By partially blocking the probe with the ribs in the elevation direction, objects outside the imaging plane were rendered in the B-mode image, which confirms that the ribs can behave as specular reflectors. In addition, we succeeded in reproducing clutter noise using a piece of polystyrene to simulate the reflections from the lungs. This indicates that the origin of the clutter noise in echocardiograms can be reverberation coming from the lungs via specular reflection at the ribs.

  20. Air Force Engineering Research Initiation Grant Program

    DTIC Science & Technology

    1994-06-21

    MISFET Structures for High-Frequency Device Applications" RI-B-91-13 Prof. John W. Silvestro Clemson University "The Effect of Scattering by a Near...Synthesis Method for Concurrent Engineering Applications" RI-B-92-03 Prof. Steven H. Collicott Purdue University "An Experimental Study of the Effect of a ...beams is studied. The effect of interply delam- inations on natural frequencies and mode shapes is evaluated analytically. A generalized variational

  1. Design study of a re-bunching RFQ for the SPES project

    NASA Astrophysics Data System (ADS)

    Shin, Seung Wook; Palmieri, A.; Comunian, M.; Grespan, F.; Chai, Jong Seo

    2014-05-01

    An upgrade to the 2nd generation of the selective production of exotic species (SPES) to produce a radioactive ion beam (RIB) has been studied at the istituto nazionale di fisica nucleare — laboratory nazionali di Legnaro (INFN-LNL). Due to the long distance between the isotope separator online (ISOL) facility and the superconducting quarter wave resonator (QWR) cavity acceleratore lineare per ioni (ALPI), a new re-buncher cavity must be introduced to maintain the high beam quality during the beam transport. A particular radio frequency quadrupole (RFQ) structure has been suggested to meet the requirements of this project. A window-type RFQ, which has a high mode separation, less power dissipation and compact size compared to the conventional normal 4-vane RFQ, has been introduced. The RF design has been studied considering the requirements of the re-bunching machine for high figures of merit such as a proper operation frequency, a high shunt impedance, a high quality factor, a low power dissipation, etc. A sensitivity analysis of the fabrication and the misalignment error has been conducted. A micro-movement slug tuner has been introduced to compensate for the frequency variations that may occur due to the beam loading, the thermal instability, the microphonic effect, etc.

  2. Microscopic heavy-ion theory. Final Report. February 2014-June 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ernst, David J.; Oberacker, Volker E.; Umar, A. Sait

    The Vanderbilt nuclear theory group conducts research in the areas of low-energy nuclear reactions and in neutrino oscillations. Specically, we study dynamics of nuclear reactions microscopically, in particular for neutron-rich nuclei which will be accessible with current and future radioactive ion beam facilities. The neutrino work concentrates on constructing computational tools for analyzing neutrino oscillation data. The most important of these is the analysis of the Super K atmospheric data. Our research concentrates on the following topics which are part of the DOE Long-Range Plan: STUDIES OF LOW-ENERGY REACTIONS OF EXOTIC NUCLEI (Professors Umar and Oberacker), including sub-barrier fusion crossmore » sections, capture cross sections for superheavy element production, and nuclear astrophysics applications. Our theory project is strongly connected to experiments at RIB facilities around the world, including NSCL-FRIB (MSU) and ATLAS-CARIBU (Argonne). PHENOMENOLOGY OF NEUTRINO OSCILLATIONS (Prof. Ernst), extracting information from existing neutrino oscillation experiments and proposing possible future experiments in order to better understand the oscillation phenomenon.« less

  3. Numerical analysis of installation damage of a pre-damaged geogrid with rectangular apertures

    NASA Astrophysics Data System (ADS)

    Dong, Yan-li; Guo, Hui-juan; Han, Jie; Zhang, Jun

    2018-06-01

    The geogrid can be damaged in the process or during construction if sufficient care is not exercised. In this study, the numerical software-FLAC was adopted to investigate the responses of pre-damaged geogrids with rectangular apertures when subjected to a uniaxial tensile load at different directions relative to the orientations of ribs in air. To simulate the combined loss of ribs and junction strength, specimens were pre-damaged by reducing certain amount of stiffness of the geogrid ribs. The geogrid ribs were modeled using beam elements jointed rigidly at nodes and subjected to tension in one direction. The numerical study demonstrated that the pre-damaged geogrid with rectangular apertures had similar responses when it was subjected to tension at the loading directions. The pre-damaged geogrids under 30° tension are the most sensitivity to the damage. With the increase of the degree of damage, the tensile strengths decreased relative quickly. An increase of the degree of installation damage of ribs decreased the tensile strength/stiffness of the geogrid with rectangular apertures. A higher reduction factor RFID due to installation damage is suggested when the geogrid is subjected to 30° tension relative to the orientation of ribs.

  4. Optimization of composite box-beam structures including effects of subcomponent interactions

    NASA Technical Reports Server (NTRS)

    Ragon, Scott A.; Guerdal, Zafer; Starnes, James H., Jr.

    1995-01-01

    Minimum mass designs are obtained for a simple box beam structure subject to bending, torque and combined bending/torque load cases. These designs are obtained subject to point strain and linear buckling constraints. The present work differs from previous efforts in that special attention is payed to including the effects of subcomponent panel interaction in the optimal design process. Two different approaches are used to impose the buckling constraints. When the global approach is used, buckling constraints are imposed on the global structure via a linear eigenvalue analysis. This approach allows the subcomponent panels to interact in a realistic manner. The results obtained using this approach are compared to results obtained using a traditional, less expensive approach, called the local approach. When the local approach is used, in-plane loads are extracted from the global model and used to impose buckling constraints on each subcomponent panel individually. In the global cases, it is found that there can be significant interaction between skin, spar, and rib design variables. This coupling is weak or nonexistent in the local designs. It is determined that weight savings of up to 7% may be obtained by using the global approach instead of the local approach to design these structures. Several of the designs obtained using the linear buckling analysis are subjected to a geometrically nonlinear analysis. For the designs which were subjected to bending loads, the innermost rib panel begins to collapse at less than half the intended design load and in a mode different from that predicted by linear analysis. The discrepancy between the predicted linear and nonlinear responses is attributed to the effects of the nonlinear rib crushing load, and the parameter which controls this rib collapse failure mode is shown to be the rib thickness. The rib collapse failure mode may be avoided by increasing the rib thickness above the value obtained from the (linear analysis based) optimizer. It is concluded that it would be necessary to include geometric nonlinearities in the design optimization process if the true optimum in this case were to be found.

  5. Study of the temperature rise induced by a focusing transducer with a wide aperture angle on biological tissue containing ribs

    NASA Astrophysics Data System (ADS)

    Xin, Wang; Jiexing, Lin; Xiaozhou, Liu; Jiehui, Liu; Xiufen, Gong

    2016-04-01

    We used the spheroidal beam equation to calculate the sound field created by focusing a transducer with a wide aperture angle to obtain the heat deposition, and then we used the Pennes bioheat equation to calculate the temperature field in biological tissue with ribs and to ascertain the effects of rib parameters on the temperature field. The results show that the location and the gap width between the ribs have a great influence on the axial and radial temperature rise of multilayer biological tissue. With a decreasing gap width, the location of the maximum temperature rise moves forward; as the ribs are closer to the transducer surface, the sound energy that passes through the gap between the ribs at the focus decreases, the maximum temperature rise decreases, and the location of the maximum temperature rise moves forward with the ribs. Project supported by the National Basic Research Program of China (Grant Nos. 2012CB921504 and 2011CB707902), the National Natural Science Foundation of China (Grant No. 11274166), the Fundamental Research Funds for the Central Universities, China (Grant No. 020414380001), the Fund from State Key Laboratory of Acoustics, Chinese Academy of Sciences (Grant No. SKLA201401), China Postdoctoral Science Foundation (Grant No. 2013M531313), and the Priority Academic Program Development of Jiangsu Higher Education Institutions and SRF for ROCS, SEM.

  6. Effect of surface texture by ion beam sputtering on implant biocompatibility and soft tissue attachment

    NASA Technical Reports Server (NTRS)

    Gibbons, D. F.

    1977-01-01

    The objectives in this report were to use the ion beam sputtering technique to produce surface textures on polymers, metals, and ceramics. The morphology of the texture was altered by varying both the width and depth of the square pits which were formed by ion beam erosion. The width of the ribs separating the pits were defined by the mask used to produce the texture. The area of the surface containing pits varies as the width was changed. The biological parameters used to evaluate the biological response to the texture were: (1) fibrous capsule and inflammatory response in subcutaneous soft tissue; (2) strength of the mechanical attachment of the textured surface by the soft tissue; and (3) morphology of the epidermal layer interfacing the textured surface of percutaneous connectors. Because the sputter yield on teflon ribs was approximately an order of magnitude larger than any other material the majority of the measurements presented in the report were obtained with teflon.

  7. Measurement of the heaviest β-delayed 2-neutron emitter: 136Sb

    NASA Astrophysics Data System (ADS)

    Caballero-Folch, R.; Dillmann, I.; Taín, J. L.; Agramunt, J.; Domingo-Pardo, C.; Algora, A.; Äystö, J.; Calviño, F.; Canete, L.; Cortès, G.; Eronen, T.; Ganioglu, E.; Gelletly, W.; Gorelov, D.; Guadilla, V.; Hakala, J.; Jokinen, A.; Kankainen, A.; Kolhinen, V.; Koponen, J.; Marta, M.; Mendoza, E.; Montaner-Pizá, A.; Moore, I.; Nobs, Ch.; Orrigo, S.; Penttilä, H.; Pohjalainen, I.; Reinikainen, J.; Riego, A.; Rinta-Antila, S.; Rubio, B.; Salvador-Castiñeira, P.; Simutkin, V.; Voss, A.

    2017-09-01

    The β-delayed neutron emission probability, Pn, of very exotic nuclei is crucial for the understanding of nuclear structure properties of many isotopes and astrophysical processes such as the rapid neutron capture process (r-process). In addition β-delayed neutrons are important in a nuclear power reactor operated in a prompt sub-critical, delayed critical condition, as they contribute to the decay heat inducing fission reactions after a shut down. The study of neutron-rich isotopes and the measurement of β-delayed one-neutron emitters (β1n) is possible thanks to the Rare Isotope Beam (RIB) facilities, where radioactive beams allow the production of exotic nuclei of interest, which can be studied and analyzed using specific detection systems. This contribution reports two recent measurements of β-delayed neutron emitters which allowed the determination of half-lives and the neutron branching ratio of isotopes in the mass region above A = 200 and N > 126, and a second experiment which confirmed 136Sb as the heaviest double neutron emitter (β2n) measured so far.

  8. Ultrasound power deposition model for the chest wall.

    PubMed

    Moros, E G; Fan, X; Straube, W L

    1999-10-01

    An ultrasound power deposition model for the chest wall was developed based on secondary-source and plane-wave theories. The anatomic model consisted of a muscle-ribs-lung volume, accounted for wave reflection and refraction at muscle-rib and muscle-lung interfaces, and computed power deposition due to the propagation of both reflected and transmitted waves. Lung tissue was assumed to be air-equivalent. The parts of the theory and numerical program dealing with reflection were experimentally evaluated by comparing simulations with acoustic field measurements using several pertinent reflecting materials. Satisfactory agreement was found. A series of simulations were performed to study the influence of angle of incidence of the beam, frequency, and thickness of muscle tissue overlying the ribs on power deposition distributions that may be expected during superficial ultrasound (US) hyperthermia of chest wall recurrences. Both reflection at major interfaces and attenuation in bone were the determining factors affecting power deposition, the dominance of one vs. the other depending on the angle of incidence of the beam. Sufficient energy is reflected by these interfaces to suggest that improvements in thermal doses to overlying tissues are possible with adequate manipulation of the sound field (advances in ultrasonic heating devices) and prospective treatment planning.

  9. Push-out tests and evaluation of FRP perfobond rib shear connectors performance

    NASA Astrophysics Data System (ADS)

    Kolpasky, Ludvik; Ryjacek, Pavel

    2017-09-01

    The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.

  10. SPIRAL2 at Ganil:. a World Leading Isol Facility for the Physics of Exotic Nuclei

    NASA Astrophysics Data System (ADS)

    Gales, S.

    2008-04-01

    During the last two decades, RIB has allowed the investigation of a new territory of nuclei with extreme N/Z called "terra incognita". Due to technical limitations, existing facilities were able to cover some part of the light mass region of this "terra incognita". The main goal of SPIRAL2 is clearly to extend our knowledge of the limit of existence and the structure of nuclei deeply in the medium and heavy mass region (A = 60 to 140) which is to day an almost unexplored continent. SPIRAL 2 is based on a high power, CW, superconducting driver LINAC, delivering 5 mA of deuteron beams at 40MeV (200KW) directed on a C converter+ Uranium target and producing therefore more 1013 fissions/s. The expected radioactive beams intensities for exotic species in the mass range from A = 60 to A = 140, of the order of 106 to 1010pps will surpass by two order of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100μA to 1 mA), heavier ions up to Ar at 14 MeV/n producing also proton rich exotic nuclei. In applied areas SPIRAL2 is considered as a powerful variable energy neutron source, a must to study the impact of nuclear fission and fusion on materials. The intensities of these unstable species are excellent opportunities for new tracers and diagnostics either for solid state, material or for radiobiological science and medicine. The "Go" decision has been taken in May 2005. The investments and personnel costs amount to 190 M€, for the construction period 2006-2012. The project group has been completed in 2006, the construction of the accelerator started in the beginning of 2007 whereas detail design of the RIB production processes are underway. Construction of the SPIRAL2 facility is shared by ten French laboratories and a network of international partners. Under the 7FP program of European Union called "Preparatory phase for the construction of new facilities", the SPIRAL2 project has been granted a budget of about 4M€ to build up an international consortium around this new venture. Regarding the future physics program a call for Letter of intents has been launched in Oct 2006. A very positive and enthusiastic response is the basis of new large international collaborations. Proposals for innovative new instrumentation and methods for the for SPIRAL2 facility are being examined by an International. Scientific Advisory Committee. The status of the construction of SPIRAL2 accelerator and technical R&D programs for physics instrumentation (detectors, spectrometers) in collaboration with EU and International partners will be presented.

  11. Shock transmission in coupled beams and rib stiffened structures

    NASA Technical Reports Server (NTRS)

    Pope, L. D.; Manning, J. E.; Scharton, T. D.

    1971-01-01

    Shock transmission in a simple coupled beam structure and in a ring-stringer stiffened cylinder is investigated experimentally and analytically using wave transmission and statistical energy analysis concepts. The use of the response spectrum to characterize the excitation provided to a simple beam by a force pulse is studied. Analysis of the transmission of a dilatation wave in a periodically stiffened plate indicates that the stiffeners are fairly transparent to the wave, but some of the dilatational energy is scattered into bending at each support.

  12. The role of acoustic nonlinearity in tissue heating behind a rib cage using a high-intensity focused ultrasound phased array

    NASA Astrophysics Data System (ADS)

    Yuldashev, Petr V.; Shmeleva, Svetlana M.; Ilyin, Sergey A.; Sapozhnikov, Oleg A.; Gavrilov, Leonid R.; Khokhlova, Vera A.

    2013-04-01

    The goal of this study was to investigate theoretically the effects of nonlinear propagation in a high-intensity focused ultrasound (HIFU) field produced by a therapeutic phased array and the resultant heating of tissue behind a rib cage. Three configurations of focusing were simulated: in water, in water with ribs in the beam path and in water with ribs backed by a layer of soft tissue. The Westervelt equation was used to model the nonlinear HIFU field, and a 1 MHz phased array consisting of 254 circular elements was used as a boundary condition to the model. The temperature rise in tissue was modelled using the bioheat equation, and thermally necrosed volumes were calculated using the thermal dose formulation. The shapes of lesions predicted by the modelling were compared with those previously obtained in in vitro experiments at low-power sonications. Intensity levels at the face of the array elements that corresponded to the formation of high-amplitude shock fronts in the focal region were determined as 10 W cm-2 in the free field in water and 40 W cm-2 in the presence of ribs. It was shown that exposures with shocks provided a substantial increase in tissue heating, and its better spatial localization in the main focal region only. The relative effects of overheating ribs and splitting of the focus due to the periodic structure of the ribs were therefore reduced. These results suggest that utilizing nonlinear propagation and shock formation effects can be beneficial for inducing confined HIFU lesions when irradiating through obstructions such as ribs. Design of compact therapeutic arrays to provide maximum power outputs with lower intensity levels at the elements is necessary to achieve shock wave regimes for clinically relevant sonication depths in tissue.

  13. SpaRibs Geometry Parameterization for Wings with Multiple Sections using Single Design

    NASA Technical Reports Server (NTRS)

    De, Shuvodeep; Jrad, Mohamed; Locatelli, Davide; Kapania, Rakesh K.; Baker, Myles; Pak, Chan-Gi

    2017-01-01

    The SpaRibs topology of an aircraft wing has a significant effect on its structural behavior and stability as well as the flutter performance. The development of additive manufacturing techniques like Electron Beam Free Form Fabrication (EBF3) has made it feasible to manufacture aircraft wings with curvilinear spars, ribs (SpaRibs) and stiffeners. In this article a new global-local optimization framework for wing with multiple sections using curvilinear SpaRibs is described. A single design space is used to parameterize the SpaRibs geometry. This method has been implemented using MSC-PATRAN to create a broad range of SpaRibs topologies using limited number of parameters. It ensures C0 and C1 continuities in SpaRibs geometry at the junction of two wing sections with airfoil thickness gradient discontinuity as well as mesh continuity between all structural components. This method is advantageous in complex multi-disciplinary optimization due to its potential to reduce the number of design variables. For the global-local optimization the local panels are generated by an algorithm which is totally based on a set algebra on the connectivity matrix data. The great advantage of this method is that it is completely independent of the coordinates of the nodes of the finite element model. It is also independent of the order in which the elements are distributed in the FEM. The code is verified by optimizing of the CRM Baseline model at trim condition at Mach number equal to 0.85 for five different angle of attack (-2deg, 0deg,2deg,4deg and 6deg). The final weight of the wing is 19,090.61 lb. This value is comparable to that obtained by Qiang et al. 6 (19,269 lb).

  14. The role of acoustic nonlinearity in tissue heating behind the rib cage using high intensity focused ultrasound phased array

    PubMed Central

    Yuldashev, Petr V.; Shmeleva, Svetlana M.; Ilyin, Sergey A.; Sapozhnikov, Oleg A.; Gavrilov, Leonid R.; Khokhlova, Vera A.

    2013-01-01

    The goal of this study was to investigate theoretically the effects of nonlinear propagation in a high intensity focused ultrasound (HIFU) field produced by a therapeutic phased array and the resultant heating of tissue behind a rib cage. Three configurations of focusing were simulated: in water, in water with ribs in the beam path, and in water with ribs backed by a layer of soft tissue. The Westervelt equation was used to model the nonlinear HIFU field and a 1 MHz phased array consisting of 254 circular elements was used as a boundary condition to the model. The temperature rise in tissue was modelled using the bioheat equation, and thermally necrosed volumes were calculated using the thermal dose formulation. The shapes of lesions predicted by the modelling were compared with those previously obtained in in vitro experiments at low power sonications. Intensity levels at the face of the array elements that corresponded to formation of high amplitude shock fronts in the focal region were determined as 10 W·cm−2 in the free field in water and 40 W·cm−2 in the presence of ribs. It was shown that exposures with shocks provided a substantial increase in tissue heating, and its better spatial localization in the main focal region only. The relative effects of overheating ribs and splitting of the focus due to the periodic structure of the ribs were therefore reduced. These results suggest that utilizing nonlinear propagation and shock formation effects can be beneficial for inducing confined HIFU lesions when irradiating through obstructions such as ribs. Design of compact therapeutic arrays to provide maximum power outputs with lower intensity levels at the elements is necessary to achieve shock wave regimes for clinically relevant sonication depths in tissue. PMID:23528338

  15. Unique considerations in the design and experimental evaluation of tailored wings with elastically produced chordwise camber

    NASA Technical Reports Server (NTRS)

    Rehfield, Lawrence W.; Zischka, Peter J.; Fentress, Michael L.; Chang, Stephen

    1992-01-01

    Some of the unique considerations that are associated with the design and experimental evaluation of chordwise deformable wing structures are addressed. Since chordwise elastic camber deformations are desired and must be free to develop, traditional rib concepts and experimental methodology cannot be used. New rib design concepts are presented and discussed. An experimental methodology based upon the use of a flexible sling support and load application system has been created and utilized to evaluate a model box beam experimentally. Experimental data correlate extremely well with design analysis predictions based upon a beam model for the global properties of camber compliance and spanwise bending compliance. Local strain measurements exhibit trends in agreement with intuition and theory but depart slightly from theoretical perfection based upon beam-like behavior alone. It is conjectured that some additional refinement of experimental technique is needed to explain or eliminate these (minor) departures from asymmetric behavior of upper and lower box cover strains. Overall, a solid basis for the design of box structures based upon the bending method of elastic camber production has been confirmed by the experiments.

  16. Monitoring and guidance of HIFU beams with dual-mode ultrasound arrays.

    PubMed

    Ballard, John R; Casper, Andrew J; Ebbini, Emad S

    2009-01-01

    We present experimental results illustrating the unique advantages of dual-mode array (DMUA) systems in monitoring and guidance of high intensity focused ultrasound (HIFU) lesion formation. DMUAs offer a unique paradigm in image-guided surgery; one in which images obtained using the same therapeutic transducer provide feedback for: 1) refocusing the array in the presence of strongly scattering objects, e.g. the ribs, 2) temperature change at the intended location of the HIFU focus, and 3) changes in the echogenicity of the tissue in response to therapeutic HIFU. These forms of feedback have been demonstrated in vitro in preparation for the design and implementation of a real-time system for imaging and therapy with DMUAs. The results clearly demonstrate that DMUA image feedback is spatially accurate and provide sufficient spatial and contrast resolution for identification of high contrast objects like the ribs and significant blood vessels in the path of the HIFU beam.

  17. Inter-costal Liver Ablation Under Real Time MR-Thermometry With Partial Activation Of A HIFU Phased Array Transducer

    NASA Astrophysics Data System (ADS)

    Quesson, Bruno; Merle, Mathilde; Köhler, Max; Mougenot, Charles; Roujol, Sebastien; de Senneville, Baudouin Denis; Moonen, Chrit

    2010-03-01

    HIFU ablation of tumours located inside the liver is hampered by the rib cage, which partially obstructs the beam path and may create adverse effects such as skin burns. This study presents a method for selectively deactivating the transducer elements causing undesired temperature increases near the bones. A manual segmentation of the bones visualized on 3D anatomical MR images acquired prior to sonication was performed to identify the beam obstruction. The resulting mask was projected (ray tracing starting from the focal point) on the transducer and elements with more than 50% obstruction of their active surface were deactivated. The effectiveness of the method for HIFU ablations is demonstrated ex vivo and in vivo in the liver of pigs with real-time MR thermometry, using the proton resonant frequency (PRF) method. For both ex vivo and in vivo experiments, the temperature increase near the bones was significantly reduced when the elements located in front of the ribs were deactivated. The temperature evolution at the focal point were similar, indicative of the absence of loss of heating efficacy when the elements were deactivated. This method is simple, rapid and reliable and allows to perform intercostal MRgHIFU ablation of the liver while sparing the ribs.

  18. Application of lightweight materials in structure concept design of large-scale solar energy unmanned aerial vehicle

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Lv, Shengli; Guan, XiQi

    2017-09-01

    Carbon fiber composites and film materials can be effectively used in light aircraft structures, especially for solar unmanned aerial vehicles. The use of light materials can reduce the weight of the aircraft, but also can effectively improve the aircraft's strength and stiffness. The structure of the large aspect ratio solar energy UAV was analyzed in detail, taking Solar-impulse solar aircraft as an example. The solar energy UAV has a wing aspect ratio greater than 20, and the detailed digital model of the wing structure including beam, ribs and skin was built, also the Finite Element Method was applied to analyze the static and dynamic performance of the structure. The upper skin of the wing is covered with silicon solar cells, while the lower skin is light and transparent film. The single beam truss form of carbon fiber lightweight material is used in the wing structure. The wing beam is a box beam with rectangular cross sections. The box beam connected the front parts and after parts of the ribs together. The fuselage of the aircraft was built by space truss structure. According to the static and dynamic analysis with Finite Element method, it was found that the aircraft has a small wingtip deflection relative to the wingspan in the level flight state. The first natural frequency of the wing structure is pretty low, which is closed to the gust load.

  19. Characterization and fabrication of target materials for RIB generation

    NASA Astrophysics Data System (ADS)

    Welton, R. F.; Janney, M. A.; Mueller, P. E.; Ortman, W. K.; Rauniyar, R.; Stracener, D. W.; Williams, C. L.

    2001-07-01

    This report discusses two techniques developed at the Oak Ridge National Laboratory (ORNL) that are employed for the fabrication and characterization of targets used in the production of Radioactive Ion Beams (RIBs). First, our method of in-house fabrication of uranium carbide targets is discussed. We have found that remarkably uniform coatings of UC2 can be formed on the microstructure of porous C matrices. The technique has been used to form UC2 layers on highly thermally conductive graphitic foams. Targets fabricated in this fashion have been tested under low-intensity proton bombardment and yields of selected radioactive species are reported. This report also describes an off-line test stand for the investigation of effusive and diffusive transport in RIB target/ion sources. Permeation rates of gases and vapors passing through a high temperature membrane or through an effusive channel constructed from the material under investigation are recorded. Diffusion coefficients and adsorption enthalpies, which characterize the interaction of RIB species with materials of the target/ion source, are extracted from the time profile of the recorded data. Examples of diffusion, effusion, and conductance measurements are provided.

  20. Coulomb Excitation of the N = 50 nucleus 80Zn

    NASA Astrophysics Data System (ADS)

    van de Walle, J.; Aksouh, F.; Ames, F.; Behrens, T.; Bildstein, V.; Blazhev, A.; Cederkäll, J.; Clément, E.; Cocolios, T. E.; Davinson, T.; Delahaye, P.; Eberth, J.; Ekström, A.; Fedorov, D. V.; Fedosseev, V. N.; Fraile, L. M.; Franchoo, S.; Gernhauser, R.; Georgiev, G.; Habs, D.; Heyde, K.; Huber, G.; Huyse, M.; Ibrahim, F.; Ivanov, O.; Iwanicki, J.; Jolie, J.; Kester, O.; Köster, U.; Kröll, T.; Krücken, R.; Lauer, M.; Lisetskiy, A. F.; Lutter, R.; Marsh, B. A.; Mayet, P.; Niedermaier, O.; Nilsson, T.; Pantea, M.; Perru, O.; Raabe, R.; Reiter, P.; Sawicka, M.; Scheit, H.; Schrieder, G.; Schwalm, D.; Seliverstov, M. D.; Sieber, T.; Sletten, G.; Smirnova, N.; Stanoiu, M.; Stefanescu, I.; Thomas, J.-C.; Valiente-Dobón, J. J.; van Duppen, P.; Verney, D.; Voulot, D.; Warr, N.; Weisshaar, D.; Wenander, F.; Wolf, B. H.; Zielińska, M.

    2008-05-01

    Neutron rich Zinc isotopes, including the N = 50 nucleus 80Zn, were produced and post-accelerated at the Radioactive Ion Beam (RIB) facility REX-ISOLDE (CERN). Low-energy Coulomb excitation was induced on these isotopes after post-acceleration, yielding B(E2) strengths to the first excited 2+ states. For the first time, an excited state in 80Zn was observed and the 21+ state in 78Zn was established. The measured B(E2,21+-->01+) values are compared to two sets of large scale shell model calculations. Both calculations reproduce the observed B(E2) systematics for the full Zinc isotopic chain. The results for N = 50 isotones indicate a good N = 50 shell closure and a strong Z = 28 proton core polarization. The new results serve as benchmarks to establish theoretical models, predicting the nuclear properties of the doubly magic nucleus 78Ni.

  1. Study of Collectivity in n-rich A=80 Nuclei using Radioactive Ion Beams

    NASA Astrophysics Data System (ADS)

    Padilla, E.; Galindo-Uribarri, A.; Baktash, C.; Fuentes, B.; Gross, C.; Mueller, P.; Radford, D. C.; Stracener, D.; Yu, C.-H.; Bijker, R.; Castanos, O.; Batchelder, J.; Hartley, D. J.

    2002-04-01

    We report on recent experiments performed at the HRIBF of Oak Ridge National Laboratory (ORNL) aimed to study neutron-rich nuclei in the A 80 mass region. First time use of Radioactive Ion Beams (RIBs) (78,80)Ge complemented with stable beam information allowed a systematic study of B(E2)-values that characterize the n-rich even-even Ge and Se isotopes. A comparison of the experimental results with IBA2 calculations will be presented. *Supported by US-DOE under the contract DE-AC05-00AOR22725.

  2. Composite uranium carbide targets at TRIUMF: Development and characterization with SEM, XRD, XRF and L-edge densitometry

    NASA Astrophysics Data System (ADS)

    Kunz, Peter; Bricault, Pierre; Dombsky, Marik; Erdmann, Nicole; Hanemaayer, Vicky; Wong, John; Lützenkirchen, Klaus

    2013-09-01

    The production of radioactive ion beams (RIB) from spallation targets by irradiation with a continuous 500 MeV proton beam, has been routine at TRIUMF for several years. Based on the experience with composite refractory carbide targets a procedure for the fabrication of UC2/C targets was developed. It includes the preparation of UC2 by carbothermal reduction of UO2, the slip-casting of fine-grained UC2/C slurry on graphite foil under inert gas atmosphere and the cutting of composite target discs which are stacked up to a lamellar structure. The thermal properties of such an arrangement are adequate to withstand the high power deposition of an intense, continuous proton beam and also beneficial for the fast release of short-lived radioactive isotopes. Molecular structure, particle size and the impact of sintering of the target discs were investigated via XRD and SEM. Thickness and mass distribution were measured with position-sensitive LIII-edge densitometry. The results confirm that the properties of the UC2/C target material are well suited for RIB production at TRIUMF while there is still room for improvement with regard to uniformity of mass distribution in target disc thickness.

  3. Enhanced heat transfer combustor technology, subtasks 1 and 2, tast C.1

    NASA Technical Reports Server (NTRS)

    Baily, R. D.

    1986-01-01

    Analytical and experimental studies are being conducted for NASA to evaluate means of increasing the heat extraction capability and service life of a liquid rocket combustor. This effort is being conducted in conjunction with other tasks to develop technologies for an advanced, expander cycle, oxygen/hydrogen engine planned for upper stage propulsion applications. Increased heat extraction, needed to raise available turbine drive energy for higher chamber pressure, is derived from combustion chamber hot gas wall ribs that increase the heat transfer surface area. Life improvement is obtained through channel designs that enhance cooling and maintain the wall temperature at an accepatable level. Laboratory test programs were conducted to evaluate the heat transfer characteristics of hot gas rib and coolant channel geometries selected through an analytical screening process. Detailed velocity profile maps, previously unavailable for rib and channel geometries, were obtained for the candidate designs using a cold flow laser velocimeter facility. Boundary layer behavior and heat transfer characteristics were determined from the velocity maps. Rib results were substantiated by hot air calorimeter testing. The flow data were analytically scaled to hot fire conditions and the results used to select two rib and three enhanced coolant channel configurations for further evaluation.

  4. Foil cooling for rep-rated electron beam pumped KrF lasers

    NASA Astrophysics Data System (ADS)

    Giuliani, J. L.; Hegeler, F.; Sethian, J. D.; Wolford, M. F.; Myers, M. C.; Abdel-Khalik, S.; Sadowski, D.; Schoonover, K.; Novak, V.

    2006-06-01

    In rep-rated electron beam pumped lasers the foil separating the vacuum diode from the laser gas is subject to repeated heating due to partial beam stopping. Three cooling methods are examined for the Electra KrF laser at the Naval Research Laboratory (NRL). Foil temperature measurements for convective cooling by the recirculating laser gas and by spray mist cooling are reported, along with estimates for thermal conductive foil cooling to the hibachi ribs. Issues on the application of each of these approaches to laser drivers in a fusion power plant are noted. Work supported by DOE/NNSA.

  5. SU-E-T-548: Modeling of Breast IORT Using the Xoft 50 KV Brachytherapy Source and 316L Steel Rigid Shield

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burnside, W

    Purpose: Xoft provides a set of 316L Stainless Steel Rigid Shields to be used with their 50 kV X-ray source for Breast IORT treatments. Modeling the different shield sizes in MCNP provides information to help make clinical decisions for selecting the appropriate shield size. Methods: The Xoft Axxent 50 kV Electronic Brachytherapy System has several applications in radiation therapy, one of which is treating cancer of the breast intraoperatively by placing the miniaturized X-ray tube inside an applicator balloon that is expanded to fill the lumpectomy bed immediately following tumor removal. The ribs, lung, and muscular chest wall are allmore » regions at risk to receive undesired dose during the treatment. A Xoft 316L Stainless Steel Rigid Shield can be placed between the intracostal muscles of the chest wall and the remaining breast tissue near the balloon to attenuate the beam and protect these organs. These shields are provided in 5 different sizes, and the effects on dose to the surrounding tissues vary with shield size. MCNP was used to model this environment and tally dose rate to certain regions of interest. Results: The average rib dose rate calculated using 0cm (i.e., no shield), 3cm, and 5cm diameter shields were 26.89, 15.43, and 8.91 Gy/hr respectively. The maximum dose rates within the rib reached 94.74 Gy/hr, 53.56 Gy/hr, and 31.44 Gy/hr for the 0cm, 3cm, and 5cm cases respectively. The shadowing effect caused by the steel shields was seen in the 3-D meshes and line profiles. Conclusion: This model predicts a higher dose rate to the underlying rib region with the 3cm shield compared to the 5cm shield; it may be useful to select the largest possible diameter when choosing a shield size for a particular IORT patient. The ability to attenuate the beam to reduce rib dose was also confirmed. Research sponsored by Xoft Inc, a subsidiary of iCAD.« less

  6. Physics division. Progress report for period ending September 30, 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ball, S.J.

    1997-04-01

    This report covers the research and development activities of the Physics Division for the 1995 and 1996 fiscal years, beginning October 1, 1994, and ending September 30, 1996. The activities of the Division continue to be concentrated in the areas of experimental nuclear physics, experimental atomic physics, and theoretical nuclear and atomic physics. In addition, there are smaller programs in plasma diagnostics and data compilation and evaluation. During the period of this report, there has been considerable success in bringing the Holifield Radioactive Ion Beam Facility (HRIBF) into routine operation. The budgets of the nuclear physics portion of the Divisionmore » have increased each year in nearly all areas, and several new members have been added to the Division research and development staff. On August 30, 1996, the HRIBF successfully accelerated its first radioactive ion beams, {sup 69}As and {sup 70}As. Prior to this, the heart of the facility, the RIB injector system, was completed, including installation of a remote handling system for the target/ion source assembly. Target and ion source development is likely to be the technical key to success of the HRIBF. We have expanded our efforts in those development areas. Of special note is the development of highly permeable composite targets which have now been shown to allow release of difficult-to-produce radioactive ions such as {sup 17,18}F. A summary of the HRIBF work is provided in Chapter 1, along with supporting activities of the Joint Institute for Heavy Ion Research.« less

  7. Optimizing sonication protocols for transthoracic focused ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Gao, J.; Volovick, A.; Cao, R.; Nabi, G.; Cochran, S.; Melzer, A.; Huang, Z.

    2012-11-01

    During transthoracic focused ultrasound surgery (TFUS), the intervening ribs absorb and reflect the majority of the ultrasound energy excited by an acoustic source, resulting in pain, bone injuries and insufficient energy delivered to the target organs of liver, kidney, and pancreas. Localized hot spots may also exist at the interfaces between the ribs and soft tissue and in the highly absorptive regions such as the skin and connective tissue. The aims of this study were to clarify the effects of focal beam distortion and frequency-dependent rib heating in TFUS and to propose possible techniques to reduce the side-effects of rib heating and increase ultrasound efficacy. Frequency-dependent heating at the target and the ribs were estimated using finite element analysis (PZFlex, Weidlinger Associates Inc, USA) along with experimental verification on a range of different phantoms. The ratio of ultrasonic power density at the target and the ribs, the time-varying spatial distribution of temperature, and the ablated focus of each sonication were taken as key indicators to determine the optimal operating frequency. Comparison with a patient specific model was also made. TFUS seems to be useful to treat tumours that are small and near the surface of the abdominal organs. For targets deep inside these organs, severe attenuation of energy occurs, suggesting that purely ultrasound thermal ablation with advanced heating patterns will have limited effects in improving the treatment efficacy. Results demonstrate that the optimal ultrasound frequency is around 0.8 MHz for the configurations considered, but this may shift to higher frequencies with changes in the axial and lateral positions of the tumours relative to the ribs. To date, we have elucidated the most important effects and correlated these with idealised anatomical geometry. The changes in frequency and other techniques such as selection of excited element patterns in FUS arrays had some effect. However, more advanced techniques need to be explored for further enhanced localised heating in the TFUS study, if this is to prove fully effective.

  8. Recent results on reactions with radioactive beams at RIBRAS (Radioactive Ion Beams in Brazil)

    NASA Astrophysics Data System (ADS)

    Lépine-Szily, A.; Lichtenthäler, R.; Guimarães, V.; Arazi, A.; Barioni, A.; Benjamim, E. A.; de Faria, P. N.; Descouvemont, P.; Gasques, L. R.; E; Leistenschneider; Mendes, D. R., Jr.; Morais, M. C.; Morcelle, V.; Moro, A. M.; Pampa Condori, R.; Pires, K. C. C.; Rodriguez-Gallardo, M.; Scarduelli, V.; Shorto, J. M. B.; Zamora, J. C.

    2015-04-01

    We present a quick description of RIBRAS (Radioactive Ion beams in Brazil), which is a superconducting double solenoid system, installed at the Pelletron Laboratory of the University of São Paulo and extends the capabilities of the original Pelletron Tandem Accelerator of 8MV terminal voltage (8UD) by producing secondary beams of unstable nuclei. The experimental program of the RIBRAS covers the study of elastic and inelastic scattering with the objective to study the interaction potential and the reaction mechanisms between weakly bound (RIB) and halo (6He and 8B) projectiles on light, medium and heavy mass targets. With highly purified beams, the study of resonant elastic scattering and resonant transfer reactions, using inverse kinematics and thick targets, have also been included in our recent experimental program.

  9. Putting the shoulder to the wheel: a new biomechanical model for the shoulder girdle.

    PubMed

    Levin, S M

    1997-01-01

    The least successfully modeled joint complex has been the shoulder. In multi-segmented mathematical shoulder models rigid beams (the bones) act as a series of columns or levers to transmit forces or loads to the axial skeleton. Forces passing through the almost frictionless joints must, somehow, always be directed perfectly perpendicular to the joints as only loads directed at right angles to the surfaces could transfer across frictionless joints. Loads transmitted to the axial skeleton would have to pass through the moving ribs or the weak jointed clavicle and then through the ribs. A new model of the shoulder girdle, based on the tension icosahedron described by Buckminster Fuller, is proposed that permits the compression loads passing through the arm and shoulder to be transferred to the axial skeleton through its soft tissues. In this model the scapula 'floats' in the tension network of shoulder girdle muscles just as the hub of the wire wheel is suspended in its tension network of spokes. With this construct inefficient beams and levers are eliminated. A more energy efficient, load distributing, integrated, hierarchical system is created.

  10. The use of aluminum nitride to improve Aluminum-26 Accelerator Mass Spectrometry measurements and production of Radioactive Ion Beams

    NASA Astrophysics Data System (ADS)

    Janzen, Meghan S.; Galindo-Uribarri, Alfredo; Liu, Yuan; Mills, Gerald D.; Romero-Romero, Elisa; Stracener, Daniel W.

    2015-10-01

    We present results and discuss the use of aluminum nitride as a promising source material for Accelerator Mass Spectrometry (AMS) and Radioactive Ion Beams (RIBs) science applications of 26Al isotopes. The measurement of 26Al in geological samples by AMS is typically conducted on Al2O3 targets. However, Al2O3 is not an ideal source material because it does not form a prolific beam of Al- required for measuring low-levels of 26Al. Multiple samples of aluminum oxide (Al2O3), aluminum nitride (AlN), mixed Al2O3-AlN as well as aluminum fluoride (AlF3) were tested and compared using the ion source test facility and the stable ion beam (SIB) injector platform at the 25-MV tandem electrostatic accelerator at Oak Ridge National Laboratory. Negative ion currents of atomic and molecular aluminum were examined for each source material. It was found that pure AlN targets produced substantially higher beam currents than the other materials and that there was some dependence on the exposure of AlN to air. The applicability of using AlN as a source material for geological samples was explored by preparing quartz samples as Al2O3 and converting them to AlN using a carbothermal reduction technique, which involved reducing the Al2O3 with graphite powder at 1600 °C within a nitrogen atmosphere. The quartz material was successfully converted to AlN. Thus far, AlN proves to be a promising source material and could lead towards increasing the sensitivity of low-level 26Al AMS measurements. The potential of using AlN as a source material for nuclear physics is also very promising by placing 26AlN directly into a source to produce more intense radioactive beams of 26Al.

  11. The use of aluminum nitride to improve Aluminum-26 Accelerator Mass Spectrometry measurements and production of Radioactive Ion Beams

    DOE PAGES

    Janzen, Meghan S.; Galindo-Uribarri, Alfredo; Liu, Yuan; ...

    2015-06-29

    In this paper, we present results and discuss the use of aluminum nitride as a promising source material for Accelerator Mass Spectrometry (AMS) and Radioactive Ion Beams (RIBs) science applications of 26Al isotopes. The measurement of 26Al in geological samples by AMS is typically conducted on Al 2O 3 targets. However, Al 2O 3 is not an ideal source material because it does not form a prolific beam of Al - required for measuring low-levels of 26Al. Multiple samples of aluminum oxide (Al 2O 3), aluminum nitride (AlN), mixed Al 2O 3–AlN as well as aluminum fluoride (AlF 3) weremore » tested and compared using the ion source test facility and the stable ion beam (SIB) injector platform at the 25-MV tandem electrostatic accelerator at Oak Ridge National Laboratory. Negative ion currents of atomic and molecular aluminum were examined for each source material. It was found that pure AlN targets produced substantially higher beam currents than the other materials and that there was some dependence on the exposure of AlN to air. The applicability of using AlN as a source material for geological samples was explored by preparing quartz samples as Al 2O 3 and converting them to AlN using a carbothermal reduction technique, which involved reducing the Al 2O 3 with graphite powder at 1600°C within a nitrogen atmosphere. The quartz material was successfully converted to AlN. Thus far, AlN proves to be a promising source material and could lead towards increasing the sensitivity of low-level 26Al AMS measurements. In conclusion, the potential of using AlN as a source material for nuclear physics is also very promising by placing 26AlN directly into a source to produce more intense radioactive beams of 26Al.« less

  12. Non-Destructive Measurement of Residual Strain in Connecting Rods Using Neutrons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikeda, Tomohiro; Bunn, Jeffrey R.; Fancher, Christopher M.

    Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases in where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-raymore » diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this paper consists of non-destructive residual strain measurements in the interior of connecting rods using the 2nd Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory, measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of connecting rod, which prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however the peak width can additionally be caused by microstresses and material dislocations.« less

  13. Retail yield and fabrication times for veal as influenced by purchasing options and merchandising styles.

    PubMed

    McNeill, M S; Griffin, D B; Dockerty, T R; Walter, J P; Johnson, H K; Savell, J W

    1998-06-01

    Twenty-nine selected styles of subprimals or sections of veal were obtained from a commercial facility to assist in the development of a support program for retailers. They were fabricated into bone-in or boneless retail cuts and associated components by trained meat cutters. Each style selected (n = 6) was used to generate mean retail yields and labor requirements, which were calculated from wholesale and retail weights and processing times. Means and standard errors for veal ribs consisting of five different styles (n = 30) concluded that style #2, 7-rib 4 (10 cm) x 4 (10 cm), had the lowest percentage of total retail yield (P < .05) owing to the greatest percentage of bone. Furthermore, rib style #2 required the longest total processing time (P < .05). Rib styles #3, 7-rib chop-ready, and #5, 6-rib chop ready, yielded the greatest percentage of total retail yield and also had the shortest total processing time (P < .05). Within veal loins, style #2, 4 (10 cm) x 4 (10 cm) loin kidney fat in, had the greatest percentage fat (P < .05). Loin styles #2 and #3, 4 (10 cm) x 4 (10 cm) loin special trimmed, generated more lean and fat trimmings and bone, resulting in lower percentage of total retail yields than loin style #1, 0 (0 cm) x 1 (2.5 cm) loin special trimmed (P < .05). Results indicated that bone-in subprimals and sections required more processing time if fabricated into a boneless end point. In addition, as the number of different retail cuts increased, processing times also increased.

  14. Ultracompact splitter for submicrometer silicon-on-insulator rib waveguides.

    PubMed

    Koster, Alain; Cassan, Eric; Laval, Suzanne; Vivien, Laurent; Pascal, Daniel

    2004-11-01

    An ultracompact and efficient 1 x 2 splitter for submicrometer silicon-on-insulator rib waveguides using a star coupler is reported. The structure proposed here is decidedly smaller than the usual splitters such as multi-mode interference or Y-branch devices and much less sensitive to technological fluctuations. Design of the compact splitter is optimized at lambda = 1.31 microm with the effective-index method and a two-dimensional beam-propagation method. The excess losses are lower than 0.15 dB, and the dependence of the losses on wavelength between 1.23 and 1.63 microm is almost flat (variation less than 0.04 dB), which makes the device very interesting for coarse wavelength-division multiplexing applications within the silicon photonic technology.

  15. Experimental determination of average turbulent heat transfer and friction factor in stator internal rib-roughened cooling channels.

    PubMed

    Battisti, L; Baggio, P

    2001-05-01

    In gas turbine cooling design, techniques for heat extraction from the surfaces exposed to the hot stream are based on the increase of the inner heat transfer areas and on the promotion of the turbulence of the cooling flow. This is currently obtained by casting periodic ribs on one or more sides of the serpentine passages into the core of the blade. Fluid dynamic and thermal behaviour of the cooling flow have been extensively investigated by means of experimental facilities and many papers dealing with this subject have appeared in the latest years. The evaluation of the average value of the heat transfer coefficient most of the time is inferred from local measurements obtained by various experimental techniques. Moreover the great majority of these studies are not concerned with the overall average heat transfer coefficient for the combined ribs and region between them, but do focus just on one of them. This paper presents an attempt to collect information about the average Nusselt number inside a straight ribbed duct. Series of measurements have been performed in steady state eliminating the error sources inherently connected with transient methods. A low speed wind tunnel, operating in steady state flow, has been built to simulate the actual flow condition occurring in a rectilinear blade cooling channel. A straight square channel with 20 transverse ribs on two sides has been tested for Re of about 3 x 10(4), 4.5 x 10(4) and 6 x 10(4). The ribbed wall test section is electrically heated and the heat removed by a stationary flow of known thermal and fluid dynamic characteristics.

  16. Rigid thin windows for vacuum applications

    DOEpatents

    Meyer, Glenn Allyn; Ciarlo, Dino R.; Myers, Booth Richard; Chen, Hao-Lin; Wakalopulos, George

    1999-01-01

    A thin window that stands off atmospheric pressure is fabricated using photolithographic and wet chemical etching techniques and comprises at least two layers: an etch stop layer and a protective barrier layer. The window structure also comprises a series of support ribs running the width of the window. The windows are typically made of boron-doped silicon and silicon nitride and are useful in instruments such as electron beam guns and x-ray detectors. In an electron beam gun, the window does not impede the electrons and has demonstrated outstanding gun performance and survivability during the gun tube manufacturing process.

  17. SU-F-T-220: Validation of Hounsfield Unit-To-Stopping Power Ratio Calibration Used for Dose Calculation in Proton Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polf, J; Chung, H; Langen, K

    Purpose: To validate the stoichiometric calibration of the Hounsfield Unit (HU) to Stopping Power Ratio (SPR) calibration used to commission a commercial treatment planning system (TPS) for proton radiotherapy dose calculation. Methods and Materials: The water equivalent thickness (WET) of several individual pig tissues (lung, fat, muscle, liver, intestine, rib, femur), mixed tissue samples (muscle/rib, ice/femur, rib/air cavity/muscle), and an intact pig head were measured with a multi-layer ionization chamber (MLIC). A CT scan of each sample was obtained and imported into a commercial TPS. The WET calculated by the TPS for each tissue sample was compared to the measuredmore » WET value to determine the accuracy of the HU-to-SPR calibration curve used by the TPS to calculate dose. Results: The WET values calculated by the TPS showed good agreement (< 2.0%) with the measured values for bone and all soft tissues except fat (3.1% difference). For the mixed tissue samples and the intact pig head measurements, the difference in the TPS and measured WET values all agreed to within 3.5%. In addition, SPR values were calculated from the measured WET of each tissue, and compared to SPR values of reference tissues from ICRU 46 used to generate the HU-to-SPR calibration for the TPS. Conclusion: For clinical scenarios where the beam passes through multiple tissue types and its path is dominated by soft tissues, we believe using an uncertainty of 3.5% of the planned beam range is acceptable to account for uncertainties in the TPS WET determination.« less

  18. Progress update on cryogenic system for ARIEL E-linac at TRIUMF

    NASA Astrophysics Data System (ADS)

    Koveshnikov, A.; Bylinskii, I.; Hodgson, G.; Yosifov, D.

    2014-01-01

    TRIUMF is involved in a major upgrade. The Advanced Rare IsotopeE Laboratory (ARIEL) has become a fully funded project in July 2010. A 10 mA 50 MeV SRF electron linac (e-linac) operating CW at 1.3 GHz is the key component of this initiative. This machine will serve as a second independent photo-fission driver for Rare Isotope Beams (RIB) production at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. The cryogens delivery system requirements are driven by the electron accelerator cryomodule design [1, 2]. Since commencement of the project in 2010 the cryogenic system of e-linac has moved from the conceptual design phase into engineering design and procurement stage. The present document summarizes the progress in cryogenic system development and construction. Current status of e-linac cryogenic system including details of LN2 storage and delivery systems, and helium subatmospheric (SA) system is presented. The first phase of e-linac consisting of two cryomodules, cryogens storage, delivery, and distribution systems, and a 600 W class liquid helium cryoplant is scheduled for installation and commissioning by year 2014.

  19. Recent Upgrades at the Fermilab Test Beam Facility

    NASA Astrophysics Data System (ADS)

    Rominsky, Mandy

    2016-03-01

    The Fermilab Test Beam Facility is a world class facility for testing and characterizing particle detectors. The facility has been in operation since 2005 and has undergone significant upgrades in the last two years. A second beam line with cryogenic support has been added and the facility has adopted the MIDAS data acquisition system. The facility also recently added a cosmic telescope test stand and improved tracking capabilities. With two operational beam lines, the facility can deliver a variety of particle types and momenta ranging from 120 GeV protons in the primary beam line down to 200 MeV particles in the tertiary beam line. In addition, recent work has focused on analyzing the beam structure to provide users with information on the data they are collecting. With these improvements, the Fermilab Test Beam facility is capable of supporting High Energy physics applications as well as industry users. The upgrades will be discussed along with plans for future improvements.

  20. Temperature dependence of yields from multi-foil SPES target

    NASA Astrophysics Data System (ADS)

    Corradetti, S.; Biasetto, L.; Manzolaro, M.; Scarpa, D.; Andrighetto, A.; Carturan, S.; Prete, G.; Zanonato, P.; Stracener, D. W.

    2011-10-01

    The temperature dependence of neutron-rich isotope yields was studied within the framework of the HRIBF-SPES Radioactive Ion Beams (RIB) project. On-line release measurements of fission fragments from a uranium carbide target at ensuremath 1600 {}^{circ}C , ensuremath 1800 {}^{circ}C and ensuremath 2000 {}^{circ}C were performed at ORNL (USA). The fission reactions were induced by a 40MeV proton beam accelerated into a uranium carbide target coupled to a plasma ion source. The experiments allowed for tests of performance of the SPES multi-foil target prototype loaded with seven UC2/graphite discs (ratio C/ U = 4 with density about 4g/cm3.

  1. The ESA/MBB unfurlable mesh antenna development for mobile services

    NASA Astrophysics Data System (ADS)

    Kellermeier, H.; Vorbrugg, H.; Pontoppidan, K.; Eaton, D. C. G.

    Mobile services via satellite in the 800-900 MHz frequency range have recently been studied by SPAR Aerospace Ltd in the M-SAT phase B using various unfurlable offset reflector concepts between 9 and 5 m aperture diameters for 6-, 4- and 2-beam coverage. For a 2-beam coverage of Canada and U.S.A. two offset antennas each of 5 m aperture diameter are required. The MBB offset unfurlable mesh antenna (UMA) developed since 1983 under an ESA contract is one of the attractive candidates: The design concept chosen uses foldable radial ribs of carbon fibre which deploy a gold plated molybdenum mesh on adjustable stand-offs. This concept is applicable for offset aperture diameters up to 12 m since the carbon fibre ribs are double folded and provide for a high package density when stowed at the spacecraft during launch. The electrical analysis performed by TICRA/Copenhagen was assisted by electrical measurements on mesh samples, verifying that main charactertics as ohmic resistance, transmission loss and passive intermodulation products (PIMP) lie within the required tolerances if the mesh is pretensioned to a certain configuration. For on-orbit testing and retrieval by the Shuttle the reflector shows a unique design feature of retractability by the reversable deployment sequence.

  2. SPIRAL2 at GANIL: A world leading ISOL facility at the dawn of the next decade

    NASA Astrophysics Data System (ADS)

    Gales, S.

    2007-07-01

    To pursue the investigation of a new territory of nuclei with extreme N/Z, called “terra incognita”, several projects, all aiming at the increase by several orders of magnitude of RIB intensities are now under discussion worldwide. In Europe, two major new projects have been approved recently: FAIR@GSI, using the so-called “in-flight” method, and SPIRAL2@GANIL, based on the ISOL method. The main goal of SPIRAL2 is clearly to extend our knowledge of the limit of existence and the structure of nuclei deeply in the medium and heavy mass region ( A=60-140), which is today an almost unexplored continent. SPIRAL2 is based on a high power, CW, superconducting driver LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 kW) directed on a C converter+ Uranium target and producing therefore more than 10 13 fissions/s. The expected radioactive beam intensities for exotic species in the mass range from A=60 to A=140, of the order of 10 6-10 10 pps will surpass by two order of magnitude any existing facility in the world. These unstable atoms will be available at energies between a few keV/n to 15 MeV/n. The same driver will accelerate high intensity (100 μA to 1 mA), heavier ions up to Ar at 14 MeV/n producing also proton rich exotic nuclei. In applied areas SPIRAL2 is considered as a powerful variable energy neutron source, a must for studying the impact of nuclear fission and fusion on materials. The intensities of these unstable species are excellent opportunities for new tracers and diagnostics either for solid state, material or for radiobiological science and medicine. The technical design has reached the point where SPIRAL2 is ready for construction. Project status and foreseen schedules will be presented. Scientific and technical R&D programs in collaboration with EU and International partners for the facility as well as for the associated innovative new instruments will be discussed.

  3. Analysis, Design and Optimization of Non-Cylindrical Fuselage for Blended-Wing-Body (BWB) Vehicle

    NASA Technical Reports Server (NTRS)

    Mukhopadhyay, V.; Sobieszczanski-Sobieski, J.; Kosaka, I.; Quinn, G.; Charpentier, C.

    2002-01-01

    Initial results of an investigation towards finding an efficient non-cylindrical fuselage configuration for a conceptual blended-wing-body flight vehicle were presented. A simplified 2-D beam column analysis and optimization was performed first. Then a set of detailed finite element models of deep sandwich panel and ribbed shell construction concepts were analyzed and optimized. Generally these concepts with flat surfaces were found to be structurally inefficient to withstand internal pressure and resultant compressive loads simultaneously. Alternatively, a set of multi-bubble fuselage configuration concepts were developed for balancing internal cabin pressure load efficiently, through membrane stress in inner-stiffened shell and inter-cabin walls. An outer-ribbed shell was designed to prevent buckling due to external resultant compressive loads. Initial results from finite element analysis appear to be promising. These concepts should be developed further to exploit their inherent structurally efficiency.

  4. Automated volume of interest delineation and rendering of cone beam CT images in interventional cardiology

    NASA Astrophysics Data System (ADS)

    Lorenz, Cristian; Schäfer, Dirk; Eshuis, Peter; Carroll, John; Grass, Michael

    2012-02-01

    Interventional C-arm systems allow the efficient acquisition of 3D cone beam CT images. They can be used for intervention planning, navigation, and outcome assessment. We present a fast and completely automated volume of interest (VOI) delineation for cardiac interventions, covering the whole visceral cavity including mediastinum and lungs but leaving out rib-cage and spine. The problem is addressed in a model based approach. The procedure has been evaluated on 22 patient cases and achieves an average surface error below 2mm. The method is able to cope with varying image intensities, varying truncations due to the limited reconstruction volume, and partially with heavy metal and motion artifacts.

  5. Hydrogeology and simulation of the effects of reclaimed-water application in west Orange and southeast Lake counties, Florida

    USGS Publications Warehouse

    O'Reilly, Andrew M.

    1998-01-01

    Wastewater reclamation and reuse has become increasingly popular as water agencies search for alternative water-supply and wastewater-disposal options. Several governmental agencies in central Florida currently use the land-based application of reclaimed water (wastewater that has been treated beyond secondary treatment) as a management alternative to surface-water disposal of wastewater. Water Conserv II, a water reuse project developed jointly by Orange County and the City of Orlando, began operation in December 1986. In 1995, the Water Conserv II facility distributed approximately 28 Mgal/d of reclaimed water for discharge to rapid-infiltration basins (RIBs) and for use as agricultural irrigation. The Reedy Creek Improvement District (RCID) began operation of RIBs in September 1990, and in 1995 these RIBs received approximately 6.7 Mgal/d of reclaimed water. Analyses of existing data and data collected during the course of this study were combined with ground-water flow modeling and particle-tracking analyses to develop a process-oriented evaluation of the regional effects of reclaimed water applied by Water Conserv II and the RCID RIBs on the hydrology of west Orange and southeast Lake Counties. The ground-water flow system beneath the study area is a multi-aquifer system that consists of a thick sequence of highly permeable carbonate rocks overlain by unconsolidated sediments. The hydrogeologic units are the unconfined surficial aquifer system, the intermediate confining unit, and the confined Floridan aquifer system, which consists of two major permeable zones, the Upper and Lower Floridan aquifers, separated by the less permeable middle semiconfining unit. Flow in the surficial aquifer system is dominated regionally by diffuse downward leakage to the Floridan aquifer system and is affected locally by lateral flow systems produced by streams, lakes, and spatial variations in recharge. Ground water generally flows laterally through the Upper Floridan aquifer aquifer to the north and east. Many of the lakes in the study area are landlocked because the mantled karst environment precludes a well developed network of surface-water drainage. The USGS three-dimensional ground-water flow model MODFLOW was used to simulate ground-water flow in the surficial and Floridan aquifer systems. A steady-state calibration to average 1995 conditions was performed by using a parameter estimation program to vary values of surficial aquifer system hydraulic conductivity, intermediate confining unit leakance, and Upper Floridan aquifer transmissivity. The calibrated model generally produced simulated water levels in close agreement with measured water levels and was used to simulate the hydrologic effects of reclaimed-water application under current (1995) and proposed future conditions. In 1995, increases of up to about 40 ft in the water table and less than 5 ft in the Upper Floridan aquifer potentiometric surface had occurred as a result of reclaimed-water application. The largest increases were under RIB sites. An average traveltime of 10 years at Water Conserv II and 7 years at the RCID RIBs was required for reclaimed water to move from the water table to the top of the Upper Floridan aquifer. Approximately 67 percent of the reclaimed water applied at the RCID RIB site recharged the Floridan aquifer system, whereas 33 percent discharged from the surficial aquifer system to surface-water features; 99 percent of the reclaimed water applied at Water Conserv II recharged the Floridan aquifer system, whereas only 1 percent discharged from the surficial aquifer system to surface-water features. The majority of reclaimed water applied at both facilities probably will ultimately discharge from the Floridan aquifer system outside the model boundaries. Proposed future conditions were assumed to consist of an additional 11.7 Mgal/d of reclaimed water distributed by the Water Conserv II and RCID facilities. Increases of up to about 20 ft in the water

  6. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Gencer, A.; Demirköz, B.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-07-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between 10 μA and 1.2 mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam flux. The DBL is designed to provide fluxes between 107 p /cm2 / s and 109 p /cm2 / s for performing irradiation tests in an area of 15.4 cm × 21.5 cm. The facility will be the first irradiation facility of its kind in Turkey.

  7. A Personal Computer-Based Head-Spine Model

    DTIC Science & Technology

    1998-09-01

    the CHSM. CHSM was comprised of the pelvis, the thoracolumbar spine, a single beam representation of the cervical spine, the head, the rib cage , and...developing the private sector HSM-PC project follows the Phase II program Work Plan , but continues into a Phase m SBIR program internally funded by...on completing the head and neck portion of HSM-PC, which as described in the Confidence Assessment Plan (CA Plan ) will be known as the Head Cervical

  8. Modeling the Biodynamical Response of the Human Thorax with Body Armor from a Bullet Impact

    DTIC Science & Technology

    2001-03-01

    inferior vena cava to the right auricle. From the right auricle, the blood is passed into the right ventricle. The right ventricle pumps the blood...the rib and vertebrae is modeled with two beam elements. To create the subcoastal angle, vertical cartilaginous connections at the inferior edge of...brachiocephalic aorta, the aorta, pulmonary arteries and veins, internal jugular veins, brachial veins, and superior vena cava . These vessels are modeled

  9. Automatic three-dimensional rib centerline extraction from CT scans for enhanced visualization and anatomical context

    NASA Astrophysics Data System (ADS)

    Ramakrishnan, Sowmya; Alvino, Christopher; Grady, Leo; Kiraly, Atilla

    2011-03-01

    We present a complete automatic system to extract 3D centerlines of ribs from thoracic CT scans. Our rib centerline system determines the positional information for the rib cage consisting of extracted rib centerlines, spinal canal centerline, pairing and labeling of ribs. We show an application of this output to produce an enhanced visualization of the rib cage by the method of Kiraly et al., in which the ribs are digitally unfolded along their centerlines. The centerline extraction consists of three stages: (a) pre-trace processing for rib localization, (b) rib centerline tracing, and (c) post-trace processing to merge the rib traces. Then we classify ribs from non-ribs and determine anatomical rib labeling. Our novel centerline tracing technique uses the Random Walker algorithm to segment the structural boundary of the rib in successive 2D cross sections orthogonal to the longitudinal direction of the ribs. Then the rib centerline is progressively traced along the rib using a 3D Kalman filter. The rib centerline extraction framework was evaluated on 149 CT datasets with varying slice spacing, dose, and under a variety of reconstruction kernels. The results of the evaluation are presented. The extraction takes approximately 20 seconds on a modern radiology workstation and performs robustly even in the presence of partial volume effects or rib pathologies such as bone metastases or fractures, making the system suitable for assisting clinicians in expediting routine rib reading for oncology and trauma applications.

  10. The ISOLDE facility and the HIE-HISOLDE project: Recent highlights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borge, M. J. G.

    2014-07-23

    The ISOLDE facility at CERN has as objective the production, study and research of nuclei far from stability. The facility provides low energy radioactive beams and post-accelerated beams. In the last 45 years the ISOLDE facility has gathered unique expertise in research with radioactive beams. Over 700 isotopes of more than 70 elements have been used in a wide range of research domains, including cutting edge studies in nuclear structure, atomic physics, nuclear astrophysics, and fundamental interactions. These nuclear probes are also used to do frontier research in solid state and life sciences. There is an on-going upgrade of themore » facility, the HIE-ISOLDE project, which aims to improve the ISOLDE capabilities in a wide front, from an energy increase of the post-accelerated beam to improvements in beam quality and beam purity. The first phase of HIE-ISOLDE will start for physics in the autumn of 2015 with an upgrade of energy for all post-accelerated ISOLDE beams up to 5.5 MeV/u. In this contribution the most recent highlights of the facility are presented.« less

  11. Towards ion beam therapy based on laser plasma accelerators.

    PubMed

    Karsch, Leonhard; Beyreuther, Elke; Enghardt, Wolfgang; Gotz, Malte; Masood, Umar; Schramm, Ulrich; Zeil, Karl; Pawelke, Jörg

    2017-11-01

    Only few ten radiotherapy facilities worldwide provide ion beams, in spite of their physical advantage of better achievable tumor conformity of the dose compared to conventional photon beams. Since, mainly the large size and high costs hinder their wider spread, great efforts are ongoing to develop more compact ion therapy facilities. One promising approach for smaller facilities is the acceleration of ions on micrometre scale by high intensity lasers. Laser accelerators deliver pulsed beams with a low pulse repetition rate, but a high number of ions per pulse, broad energy spectra and high divergences. A clinical use of a laser based ion beam facility requires not only a laser accelerator providing beams of therapeutic quality, but also new approaches for beam transport, dosimetric control and tumor conformal dose delivery procedure together with the knowledge of the radiobiological effectiveness of laser-driven beams. Over the last decade research was mainly focused on protons and progress was achieved in all important challenges. Although currently the maximum proton energy is not yet high enough for patient irradiation, suggestions and solutions have been reported for compact beam transport and dose delivery procedures, respectively, as well as for precise dosimetric control. Radiobiological in vitro and in vivo studies show no indications of an altered biological effectiveness of laser-driven beams. Laser based facilities will hardly improve the availability of ion beams for patient treatment in the next decade. Nevertheless, there are possibilities for a need of laser based therapy facilities in future.

  12. The Fundamental Neutron Physics Facilities at NIST.

    PubMed

    Nico, J S; Arif, M; Dewey, M S; Gentile, T R; Gilliam, D M; Huffman, P R; Jacobson, D L; Thompson, A K

    2005-01-01

    The program in fundamental neutron physics at the National Institute of Standards and Technology (NIST) began nearly two decades ago. The Neutron Interactions and Dosimetry Group currently maintains four neutron beam lines dedicated to studies of fundamental neutron interactions. The neutrons are provided by the NIST Center for Neutron Research, a national user facility for studies that include condensed matter physics, materials science, nuclear chemistry, and biological science. The beam lines for fundamental physics experiments include a high-intensity polychromatic beam, a 0.496 nm monochromatic beam, a 0.89 nm monochromatic beam, and a neutron interferometer and optics facility. This paper discusses some of the parameters of the beam lines along with brief presentations of some of the experiments performed at the facilities.

  13. The Fundamental Neutron Physics Facilities at NIST

    PubMed Central

    Nico, J. S.; Arif, M.; Dewey, M. S.; Gentile, T. R.; Gilliam, D. M.; Huffman, P. R.; Jacobson, D. L.; Thompson, A. K.

    2005-01-01

    The program in fundamental neutron physics at the National Institute of Standards and Technology (NIST) began nearly two decades ago. The Neutron Interactions and Dosimetry Group currently maintains four neutron beam lines dedicated to studies of fundamental neutron interactions. The neutrons are provided by the NIST Center for Neutron Research, a national user facility for studies that include condensed matter physics, materials science, nuclear chemistry, and biological science. The beam lines for fundamental physics experiments include a high-intensity polychromatic beam, a 0.496 nm monochromatic beam, a 0.89 nm monochromatic beam, and a neutron interferometer and optics facility. This paper discusses some of the parameters of the beam lines along with brief presentations of some of the experiments performed at the facilities. PMID:27308110

  14. Characterization of a 5-eV neutral atomic oxygen beam facility

    NASA Technical Reports Server (NTRS)

    Vaughn, J. A.; Linton, R. C.; Carruth, M. R., Jr.; Whitaker, A. F.; Cuthbertson, J. W.; Langer, W. D.; Motley, R. W.

    1991-01-01

    An experimental effort to characterize an existing 5-eV neutral atomic oxygen beam facility being developed at Princeton Plasma Physics Laboratory is described. This characterization effort includes atomic oxygen flux and flux distribution measurements using a catalytic probe, energy determination using a commercially designed quadrupole mass spectrometer (QMS), and the exposure of oxygen-sensitive materials in this beam facility. Also, comparisons were drawn between the reaction efficiencies of materials exposed in plasma ashers, and the reaction efficiencies previously estimated from space flight experiments. The results of this study show that the beam facility is capable of producing a directional beam of neutral atomic oxygen atoms with the needed flux and energy to simulate low Earth orbit (LEO) conditions for real time accelerated testing. The flux distribution in this facility is uniform to +/- 6 percent of the peak flux over a beam diameter of 6 cm.

  15. Analysis of prestressed concrete slab-and-beam structures

    NASA Astrophysics Data System (ADS)

    Sapountzakis, E. J.; Katsikadelis, J. T.

    In this paper a solution to the problem of prestressed concrete slab-and-beam structures including creep and shrinkage effect is presented. The adopted model takes into account the resulting inplane forces and deformations of the plate as well as the axial forces and deformations of the beam, due to combined response of the system. The analysis consists in isolating the beams from the plate by sections parallel to the lower outer surface of the plate. The forces at the interface, which produce lateral deflection and inplane deformation to the plate and lateral deflection and axial deformation to the beam, are established using continuity conditions at the interface. The influence of creep and shrinkage effect relative with the time of the casting and the time of the loading of the plate and the beams is taken into account. The estimation of the prestressing axial force of the beams is accomplished iteratively. Both instant (e.g. friction, slip of anchorage) and time dependent losses are encountered. The solution of the arising plate and beam problems, which are nonlinearly coupled, is achieved using the analog equation method (AEM). The adopted model, compared with those ignoring the inplane forces and deformations, describes better the actual response of the plate-beams system and permits the evaluation of the shear forces at the interfaces, the knowledge of which is very important in the design of prefabricated ribbed plates.

  16. Shielding and Activation Analyses for BTF Facility at SNS

    NASA Astrophysics Data System (ADS)

    Popova, Irina; Gallmeier, Franz X.

    2017-09-01

    The beam test facility (BTF), which simulates front end of the Spallation Neutron Source (SNS), has been built at the SNS, and is preparing for commissioning. The BTF has been assembled and will operate in one of service buildings at the site. The 2.5 MeV proton beam, produced in the facility, will be stopped in the beam dump. In order to support BTF project from radiation protection site, neutronics simulations and activation analyses were performed to evaluate the necessary shielding around the facility and radionuclide inventory of the beam stop.

  17. Accelerator Facilities for Radiation Research

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.

    1999-01-01

    HSRP Goals in Accelerator Use and Development are: 1.Need for ground-based heavy ion and proton facility to understand space radiation effects discussed most recently by NAS/NRC Report (1996). 2. Strategic Program Goals in facility usage and development: -(1) operation of AGS for approximately 600 beam hours/year; (2) operation of Loma Linda University (LLU) proton facility for approximately 400 beam hours/year; (3) construction of BAF facility; and (4) collaborative research at HIMAC in Japan and with other existing or potential international facilities. 3. MOA with LLU has been established to provide proton beams with energies of 40-250 important for trapped protons and solar proton events. 4. Limited number of beam hours available at Brookhaven National Laboratory's (BNL) Alternating Gradient Synchrotron (AGS).

  18. Cough-induced rib fractures.

    PubMed

    Hanak, Viktor; Hartman, Thomas E; Ryu, Jay H

    2005-07-01

    To define the demographic, clinical, and radiological features of patients with cough-induced rib fractures and to assess potential risk factors. For this retrospective, single-center study, we identified all cases of cough-induced rib fractures diagnosed at the Mayo Clinic in Rochester, Minn, over a 9-year period between January 1, 1996, and January 31, 2005. Bone densitometry data from patients' medical records were analyzed, and T scores were used to classify patients into bone density categories. The mean +/- SD age of the 54 study patients at presentation was 55+/-17 years, and 42 patients (78%) were female. Patients presented with chest wall pain after onset of cough. Rib fracture was associated with chronic cough (> or =3 weeks' duration) in 85% of patients. Rib fractures were documented by chest radiography, rib radiography, computed tomography, or bone scan. Chest radiography had been performed in 52 patients and revealed rib fracture in 30 (58%). There were 112 fractured ribs in 54 patients. One half of patients had more than one fractured rib. Right-sided rib fractures alone were present in 17 patients (26 fractured ribs), left-sided in 23 patients (35 fractured ribs), and bilateral in 14 patients (51 fractured ribs). The most commonly fractured rib on both sides was rib 6. The fractures were most common at the lateral aspect of the rib cage. Bone densitometry was done in 26 patients and revealed osteopenia or osteoporosis in 17 (65%). Cough-induced rib fractures occur primarily in women with chronic cough. Middle ribs along the lateral aspect of the rib cage are affected most commonly. Although reduced bone density is likely a risk factor, cough-induced rib fractures can occur in the presence of normal bone density.

  19. Analysis of the current rib support practices and techniques in U.S. coal mines

    PubMed Central

    Mohamed, Khaled M.; Murphy, Michael M.; Lawson, Heather E.; Klemetti, Ted

    2016-01-01

    Design of rib support systems in U.S. coal mines is based primarily on local practices and experience. A better understanding of current rib support practices in U.S. coal mines is crucial for developing a sound engineering rib support design tool. The objective of this paper is to analyze the current practices of rib control in U.S. coal mines. Twenty underground coal mines were studied representing various coal basins, coal seams, geology, loading conditions, and rib control strategies. The key findings are: (1) any rib design guideline or tool should take into account external rib support as well as internal bolting; (2) rib bolts on their own cannot contain rib spall, especially in soft ribs subjected to significant load—external rib control devices such as mesh are required in such cases to contain rib sloughing; (3) the majority of the studied mines follow the overburden depth and entry height thresholds recommended by the Program Information Bulletin 11-29 issued by the Mine Safety and Health Administration; (4) potential rib instability occurred when certain geological features prevailed—these include draw slate and/or bone coal near the rib/roof line, claystone partings, and soft coal bench overlain by rock strata; (5) 47% of the studied rib spall was classified as blocky—this could indicate a high potential of rib hazards; and (6) rib injury rates of the studied mines for the last three years emphasize the need for more rib control management for mines operating at overburden depths between 152.4 m and 304.8 m. PMID:27648341

  20. KSC-04pd0459

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Workers in the Orbiter Processing Facility help move the body flap into position on the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  1. KSC-04pd0452

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility, the body flap for the orbiter Discovery is prepared for installation. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  2. Rib fractures and their association With solid organ injury: higher rib fractures have greater significance for solid organ injury screening.

    PubMed

    Rostas, Jack W; Lively, Timothy B; Brevard, Sidney B; Simmons, Jon D; Frotan, Mohammad A; Gonzalez, Richard P

    2017-04-01

    The purpose of this study was to identify patients with rib injuries who were at risk for solid organ injury. A retrospective chart review was performed of all blunt trauma patients with rib fractures during the period from July 2007 to July 2012. Data were analyzed for association of rib fractures and solid organ injury. In all, 1,103 rib fracture patients were identified; 142 patients had liver injuries with 109 (77%) associated right rib fractures. Right-sided rib fractures with highest sensitivity for liver injury were middle rib segment (5 to 8) and lower segment (9 to 12) with liver injury sensitivities of 68% and 43%, respectively (P < .001); 151 patients had spleen injuries with 119 (79%) associated left rib fractures. Left middle segment rib fractures and lower segment rib fractures had sensitivities of 80% and 63% for splenic injury, respectively (P < .003). Rib fractures higher in the thoracic cage have significant association with solid organ injury. Using rib fractures from middle plus lower segments as indication for abdominal screening will significantly improve rib fracture sensitivity for identification of solid organ injury. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Astrophysics at the future Rare Isotope Accelerator

    NASA Astrophysics Data System (ADS)

    Smith, Michael; Schatz, Hendrik; Timmes, Frank X.; Wiescher, Michael; Greife, Uwe

    PoS(NIC-IX)179 Significant progress in studies of core collapse supernovae, thermonuclear supernovae, X-ray bursts, novae, and other astrophysical phenomena require intense beams of a wide range of unsta- ble nuclei. While some such beams are currently available and being used for important studies in nuclear astrophysics, the beams are often insufficient in intensity, purity, or available isotopes. It is anticipated that a next-generation radioactive beam facility will be built in the U.S. in the next decade to address these shortcomings, and a Working Group has been established to develop and promote nuclear astrophysics research at this new facility. Many of the topics addressed by the Working Group are relevant for the RIKEN RI Beam Factory, the planned GSI-Fair facility, and other advanced radioactive beam facilities around the world.

  4. Production of negatively charged radioactive ion beams

    DOE PAGES

    Liu, Y.; Stracener, D. W.; Stora, T.

    2017-02-15

    Beams of short-lived radioactive nuclei are needed for frontier experimental research in nuclear structure, reactions, and astrophysics. Negatively charged radioactive ion beams have unique advantages and allow for the use of a tandem accelerator for post-acceleration, which can provide the highest beam quality and continuously variable energies. Negative ion beams can be obtained with high intensity and some unique beam purification techniques based on differences in electronegativity and chemical reactivity can be used to provide beams with high purity. This article describes the production of negative radioactive ion beams at the former holifield radioactive ion beam facility at Oak Ridgemore » National Laboratory and at the CERN ISOLDE facility with emphasis on the development of the negative ion sources employed at these two facilities.« less

  5. "Buckle" rib fracture: an artifact following cardio-pulmonary resuscitation detected on postmortem CT.

    PubMed

    Yang, Kyung-Moo; Lynch, Matthew; O'Donnell, Chris

    2011-09-01

    Buckle rib fractures are incomplete fractures involving the inner cortex alone, and are rarely detected on routine chest X-ray or at autopsy. The characteristics of these fractures have not been well evaluated in situ although they are commonly observed on postmortem CT images especially following CPR. The postmortem CT findings in 42 cases showing buckle rib fractures caused by CPR were reviewed. The cause of death in all cases was non-traumatic. The shape, number, location, and distribution of these buckle rib fractures and their relationship to other types of rib fractures were evaluated using a novel oblique axial multiplanar reconstruction technique. Almost all incomplete rib fractures associated with CPR are buckle rib fractures (90.5%). All rib fractures were distributed from the second to ninth ribs with over 95% being within the second to seventh ribs. Buckle rib fractures are dominant in the seventh to ninth ribs and the proportion of buckle rib fractures located in the vicinity of the costochondral junctions increases with the lower ribs. Over 97% of all CPR associated rib fractures are located in the anterior one third of the ribs based on a new measurement method utilizing oblique axial multiplanar reconstruction of the CT data. When recognition of incomplete or buckle rib fractures on postmortem CT is taken into account, detection of symmetry and continuity of rib fractures typically associated with CPR is improved compared with the detection of complete fractures alone. Recognition of buckle rib fractures and their characteristics on postmortem CT is of benefit to the forensic pathologist in evaluating the possibility of CPR and the differentiation of resuscitative artifact from forensically significant visceral injury observed at autopsy. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Development of a socket-type rib coaptation device made of poly-L-lactide fibers: feasibility study in a canine model

    PubMed Central

    Komatsu, Teruya; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo

    2018-01-01

    Background Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. Methods We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. Results All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. Conclusions The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs. PMID:29850125

  7. Development of a socket-type rib coaptation device made of poly-L-lactide fibers: feasibility study in a canine model.

    PubMed

    Komatsu, Teruya; Sato, Toshihiko; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo

    2018-04-01

    Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs.

  8. Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.

    PubMed

    Sano, Atsushi

    2018-05-01

     The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography.  Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window.  In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case.  In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.

  9. Anatomically contoured plates for fixation of rib fractures.

    PubMed

    Bottlang, Michael; Helzel, Inga; Long, William B; Madey, Steven

    2010-03-01

    : Intraoperative contouring of long bridging plates for stabilization of flail chest injuries is difficult and time consuming. This study implemented for the first time biometric parameters to derive anatomically contoured rib plates. These plates were tested on a range of cadaveric ribs to quantify plate fit and to extract a best-fit plating configuration. : Three left and three right rib plates were designed, which accounted for anatomic parameters required when conforming a plate to the rib surface. The length lP over which each plate could trace the rib surface was evaluated on 109 cadaveric ribs. For each rib level 3-9, the plate design with the highest lP value was extracted to determine a best-fit plating configuration. Furthermore, the characteristic twist of rib surfaces was measured on 49 ribs to determine the surface congruency of anatomic plates with a constant twist. : The tracing length lP of the best-fit plating configuration ranged from 12.5 cm to 14.7 cm for ribs 3-9. The corresponding range for standard plates was 7.1-13.7 cm. The average twist of ribs over 8-cm, 12-cm, and 16-cm segments was 8.3 degrees, 20.6 degrees, and 32.7 degrees, respectively. The constant twist of anatomic rib plates was not significantly different from the average rib twist. : A small set of anatomic rib plates can minimize the need for intraoperative plate contouring for fixation of ribs 3-9. Anatomic rib plates can therefore reduce the time and complexity of flail chest stabilization and facilitate spanning of flail segments with long plates.

  10. Development of ductile hybrid fiber reinforced polymer (D-H-FRP) reinforcement for concrete structures

    NASA Astrophysics Data System (ADS)

    Somboonsong, Win

    The corrosion of steel rebars has been the major cause of the reinforced concrete deterioration in transportation structures and port facilities. Currently, the Federal Highway Administration (FHWA) spends annually $31 billion for maintaining and repairing highways and highway bridges. The study reported herein represents the work done in developing a new type of reinforcement called Ductile Hybrid Fiber Reinforced Polymer or D-H-FRP using non-corrosive fiber materials. Unlike the previous FRP reinforcements that fail in a brittle manner, the D-H-FRP bars exhibit the stress-strain curves that are suitable for concrete reinforcement. The D-H-FRP stress-strain curves are linearly elastic with a definite yield point followed by plastic deformation and strain hardening resembling that of mild steel. In addition, the D-H-FRP reinforcement has integrated ribs required for concrete bond. The desirable mechanical properties of D-H-FRP reinforcement are obtained from the integrated design based on the material hybrid and geometric hybrid concepts. Using these concepts, the properties can be tailored to meet the specific design requirements. An analytical model was developed to predict the D-H-FRP stress-strain curves with different combination of fiber materials and geometric configuration. This model was used to optimize the design of D-H-FRP bars. An in-line braiding-pultrusion manufacturing process was developed at Drexel University to produce high quality D-H-FRP reinforcement in diameters that can be used in concrete structures. A series of experiments were carried out to test D-H-FRP reinforcement as well as their individual components in monotonic and cyclic tensile tests. Using the results from the tensile tests and fracture analysis, the stress-strain behavior of the D-H-FRP reinforcement was fully characterized and explained. Two series of concrete beams reinforced with D-H-FRP bars were studied. The D-H-FRP beam test results were then compared with companion steel reinforced concrete beams having the same ultimate strength. All D-H-FRP reinforced concrete beams show consistent performance with ultimate strengths and ductility similar to the steel reinforced control specimens and to theoretical predictions.

  11. Novel classification system of rib fractures observed in infants.

    PubMed

    Love, Jennifer C; Derrick, Sharon M; Wiersema, Jason M; Pinto, Deborrah C; Greeley, Christopher; Donaruma-Kwoh, Marcella; Bista, Bibek

    2013-03-01

    Rib fractures are considered highly suspicious for nonaccidental injury in the pediatric clinical literature; however, a rib fracture classification system has not been developed. As an aid and impetus for rib fracture research, we developed a concise schema for classifying rib fracture types and fracture location that is applicable to infants. The system defined four fracture types (sternal end, buckle, transverse, and oblique) and four regions of the rib (posterior, posterolateral, anterolateral, and anterior). It was applied to all rib fractures observed during 85 consecutive infant autopsies. Rib fractures were found in 24 (28%) of the cases. A total of 158 rib fractures were identified. The proposed schema was adequate to classify 153 (97%) of the observed fractures. The results indicate that the classification system is sufficiently robust to classify rib fractures typically observed in infants and should be used by researchers investigating infant rib fractures. © 2013 American Academy of Forensic Sciences.

  12. A button - type beam position monitor design for TARLA facility

    NASA Astrophysics Data System (ADS)

    Gündoǧan, M. Tural; Kaya, ć.; Yavaş, Ö.

    2016-03-01

    Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC. The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.

  13. Evaluating the point of separation, during carcass fabrication, between the beef wholesale rib and the beef wholesale chuck.

    PubMed

    Reuter, B J; Wulf, D M; Shanks, B C; Maddock, R J

    2002-01-01

    This study determined whether there is a logical point of value change, related to either tenderness or consumer acceptance, at which to separate the beef carcass within the rib/chuck region. Rib/chuck rolls (RCR); (n = 30) consisting of the ribeye roll and chuck eye roll subprimals (2nd through 12th rib locations) were cut into 22 steaks each (two steaks per rib location), and Warner-Bratzler shear force and consumer purchase preference were evaluated for steaks at each rib location. Steaks from different locations of the RCR were composed of differing proportions of several muscles: longissimus muscle (LM), spinalis dorsi and multifidus dorsi (SM), and complexus (CO). The LM (4th to 12th rib) contained three tenderness regions: 7th through 12th rib, 5th and 6th ribs, and 4th rib regions (lowest, intermediate, and highest shear force values, respectively; P < 0.01). Shear force differed (P < 0.05) among rib locations for the SM (2nd to 9th rib), but no logical pattern was evident. The CO (2nd to 7th rib) was more tender toward the anterior end (P < 0.05). The region of the RCR represented by the 4th through 6th rib locations had steaks with higher weighted-average shear force (average shear force of each steak, weighted for surface area of each muscle) values than the remainder of the RCR (P < 0.05). Animal-to-animal variation in shear force was 36% greater than rib-to-rib variation in shear force; thus, statistically significant differences in tenderness among rib locations may be undetectable by consumers. Steaks (n = 330) were offered for sale at a retail supermarket and case time was monitored on each steak to determine consumer purchase preference. Steaks from the 2nd through 4th rib locations required more time to sell (P < 0.01) than steaks from the 5th through 12th rib locations. Two alternative locations for the rib/chuck separation point could be between the 6th and 7th ribs, yielding a ribeye subprimal useful in marketing a "premium quality" product, or between the 4th and 5th ribs, which would yield four more 2.5-cm ribeye steaks per carcass.

  14. KSC-04pd0458

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Workers in the Orbiter Processing Facility lean toward the body flap to be installed on the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  15. KSC-04pd0456

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility, the body flap is moved into position for installation on the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  16. KSC-04pd0454

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - A Hyster forklift in the Orbiter Processing Facility lifts the body flap to be installed on the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  17. KSC-04pd0453

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - Workers in the Orbiter Processing Facility help prepare the body flap for lifting prior to installation on the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  18. KSC-04pd0457

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility, the body flap is moved into position for installation on the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  19. KSC-04pd0455

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - A Hyster forklift in the Orbiter Processing Facility moves the body flap toward the aft of the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  20. KSC-04pd0460

    NASA Image and Video Library

    2004-03-12

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility, A Hyster forklift supports the body flap as workers secure it to the orbiter Discovery. The body flap is an aluminum structure consisting of ribs, spars, skin panels and a trailing edge assembly. It thermally shields the three main engines during entry and provides pitch control trim during landing approach. Discovery is being processed for launch on the first Return to Flight mission, STS-114.

  1. 14. FACILITY IDENTIFICATION STENCILED ON ROOF BEAM, 'RIGGING LOFT' PORTION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. FACILITY IDENTIFICATION STENCILED ON ROOF BEAM, 'RIGGING LOFT' PORTION OF BUILDING 4. - Chollas Heights Naval Radio Transmitting Facility, Public Works Shop, 6410 Zero Road, San Diego, San Diego County, CA

  2. Increasing number of fractured ribs is not predictive of the severity of splenic injury following blunt trauma: an analysis of a National Trauma Registry database.

    PubMed

    Boris, Kessel; Forat, Swaid; Itamar, Ashkenazi; Oded, Olsha; Kobi, Peleg; Adi, Givon; Igor, Jeroukhimov; Ricardo, Alfici

    2014-05-01

    Association between rib fractures and incidence of abdominal solid organs injury is well described. However, the correlation between the number of fractured ribs and severity of splenic injury is not clear. The purpose of this study was to assess whether an increasing number of rib fractures predicts the severity of splenic injury in blunt trauma patients. A retrospective cohort study involving blunt trauma patients with concomitant splenic injuries and rib fractures, between the years 1998 and 2012, registered in the Israeli National Trauma Registry. Of 321,618 patients with blunt mechanism of trauma, 57,130 had torso injuries, and of these 14,651 patients sustained rib fractures, and 3691 patients suffered from splenic injury. Concomitant splenic injury occurred in 1326 of the patients with rib fractures (9.1%), as compared to 2365 patients sustaining splenic injury without rib fractures (5.6%). The incidence of splenic injury among patients sustaining 5 or more rib fractures was significantly higher compared to patients suffering from 1 to 4 rib fractures. Among patients with splenic injury, the tendency to sustain associated rib fractures increased steadily with age. Patients with concomitant rib fractures had higher Injury Severity Score (ISS), but similar mortality rates, compared to patients with splenic injury without rib fractures. Among patients with concomitant rib fractures and splenic injury, there was no relation between the number of fractured ribs and the severity of splenic injury, neither as a whole group, nor after stratification according to the mechanism of injury. Although the presence of rib fractures increases the probability of splenic injury in blunt torso trauma, there is no relation between the number of fractured ribs and splenic injury severity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Rib fracture fixation in the 65 years and older population: A paradigm shift in management strategy at a Level I trauma center.

    PubMed

    Fitzgerald, Michael T; Ashley, Dennis W; Abukhdeir, Hesham; Christie, D Benjamin

    2017-03-01

    Rib fractures after chest wall trauma are a common injury; however, they carry a significant morbidity and mortality risk. The impact of rib fractures in the 65-year and older patient population has been well documented as have the mortality and pneumonia rates. We hypothesize that patients 65 years and older receiving rib plating (RP) have decreased mortality, complication rates, and an accelerated return to normal functional states when compared with controls. With institutional review board approval, a retrospective review analyzed patients 65 years and older with rib fractures admitted from 2009 to 2015 receiving RP (RP group) (n = 23) compared to nonoperative, injury-matched controls admitted from 2003 to 2008 (NO group) (n = 50). Patients were followed prospectively with regard to lifestyle and functional satisfaction. Independent variables analyzed included Injury Severity Score (ISS), number of rib fractures, mortalities, hospital days, intensive care unit days, pneumonia development, respiratory complications, readmission rates, need for and length of rehabilitation stay time. Comparisons were by χ tests/Fisher's exact tests, Student's t tests and Wilcoxon rank sum tests. From 2003 to 2008, 50 NO patients were admitted with ages ranging 65 to 97 years, average ISS of 18.47 (14.28-22.66) versus ages ranging from 63 to 89 years, average ISS of 20.71 (15.7-25.73) for the RP group (n = 23). Average hospital days were 16.76 (10.35-23.18) and 18.36 (13.61-23.11) in the NO and RP groups, respectively. Average intensive care unit days were 11.65 (6.45-16.85) and 8.29 (5.31-11.26) days in the NO and RP groups, respectively. Four respiratory readmissions, two deaths, seven pneumonias, seven pleural-effusions, and 19 recurrent pneumothoraces were encountered in the NO group versus 0 in the RP group (p < 0.001). An equal percentage of patients in both groups entered rehabilitation facilities with average stay time of 18.5 and 28.53 days for the RP and NO groups, respectively. RP in the 65-year and older trauma population demonstrates a measurable decrease in mortality and respiratory complications, improves respiratory mechanics, and permits an accelerated return to functioning state. Therapeutic/care management study, level IV.

  4. Cavernous hemangioma of the rib: a rare diagnosis.

    PubMed

    Gourgiotis, Stavros; Piyis, Anastasios; Panagiotopoulos, Nikolaos; Panayotopoulos, Panayotis; Salemis, Nikolaos S

    2010-01-01

    Hemangioma of the rib is an uncommon benign vascular tumour. A case of rib hemangioma in a 29-year-old woman is presented. Chest roentgenogram and computed tomography revealed a mass along the inner surface of the 7th left rib with bone destruction. She underwent resection of the 7th rib. The pathologic diagnosis was cavernous hemangioma. Hemangiomas of the rib are rare tumours but should be kept in mind in the differential diagnosis of rib tumours.

  5. A 3' UTR-derived non-coding RNA RibS increases expression of cfa and promotes biofilm formation of Salmonella enterica serovar Typhi.

    PubMed

    Zhao, Xin; Liu, Rui; Tang, Hao; Osei-Adjei, George; Xu, Shungao; Zhang, Ying; Huang, Xinxiang

    2018-05-08

    Bacterial non-coding RNAs (ncRNAs) are widely studied and found to play important roles in regulating various cellular processes. Recently, many ncRNAs have been discovered to be transcribed or processed from 3' untranslated regions (3' UTRs). Here we reported a novel 3' UTR-derived ncRNA, RibS, which could influence biofilm formation of Salmonella enterica serovar Typhi (S. Typhi). RibS was confirmed to be a ∼700 nt processed product produced by RNase III-catalyzed cleavage from the 3' UTR of riboflavin synthase subunit alpha mRNA, RibE. Overexpression of RibS increased the expression of the cyclopropane fatty acid synthase gene, cfa, which was located at the antisense strand. Biofilm formation of S. Typhi was enhanced by overexpressing RibS both in the wild type strain and cfa deletion mutant. Deletion of cfa attenuated biofilm formation of S. Typhi, while complementation of cfa partly restored the phenotype. Moreover, overexpressing cfa enhanced the biofilm formation of S. Typhi. In summary, RibS has been identified as a novel ncRNA derived from the 3' UTR of RibE that promotes biofilm formation of S. Typhi, and it appears to do so, at least in part, by increasing the expression of cfa. Copyright © 2018 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  6. Local heat transfer distribution in a square channel with 90 continuous, 90 saw tooth profiled and 60 broken ribs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Abhishek; SriHarsha, V.; Prabhu, S.V.

    2008-02-15

    Internal channel cooling is employed in advanced gas turbines blade to allow high inlet temperatures so as to achieve high thrust/weight ratios and low specific fuel consumption. The objective of the present study is to measure the local heat transfer distributions in a double wall ribbed square channel with 90 continuous, 90 saw tooth profiled and 60 V-broken ribs. Comparison is made between the 90 continuous ribs (P/e = 7 and 10 for a e/D = 0.15) and 90 saw tooth profiled rib configurations (P/e = 7 for an e/D = 0.15) for the same rib height to the hydraulicmore » diameter ratio (e/D). The effect of pitch to rib height ratio (P/e = 7.5,10 and 12) of 60 V-broken ribbed channel with a constant rib height to hydraulic diameter ratio (e/D) of 0.0625 on the local heat transfer distribution is studied. The Reynolds number based on duct hydraulic diameter is ranging from 10,000 to 30,000. A thin stainless steel foil of 0.05 mm thickness is used as heater and infrared thermography technique is used to obtain the local temperature distribution on the surface. The images are captured in the periodically fully developed region of the channel. It is observed that the heat transfer augmentations in the channel with 90 saw tooth profiled ribs are comparable with those of 90 continuous ribs. The enhancements caused by 60 V-broken ribs are higher than those of 90 continuous ribs. The effect of pitch to the rib height ratio (P/e) is not significant for channel with 60 V-broken ribs for a given rib height to hydraulic diameter ratio (e/D = 0.0625). (author)« less

  7. Cavernous Hemangioma of the Rib: A Rare Diagnosis

    PubMed Central

    Gourgiotis, Stavros; Piyis, Anastasios; Panagiotopoulos, Nikolaos; Panayotopoulos, Panayotis; Salemis, Nikolaos S.

    2010-01-01

    Hemangioma of the rib is an uncommon benign vascular tumour. A case of rib hemangioma in a 29-year-old woman is presented. Chest roentgenogram and computed tomography revealed a mass along the inner surface of the 7th left rib with bone destruction. She underwent resection of the 7th rib. The pathologic diagnosis was cavernous hemangioma. Hemangiomas of the rib are rare tumours but should be kept in mind in the differential diagnosis of rib tumours. PMID:20585365

  8. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins under epidural anesthesia].

    PubMed

    Liu, Jinliang; Li, Keyao; Ju, Zhenlong; Bai, Yan

    2011-03-01

    To study the indications, methods and experience of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. 52 cases with multiple rib fractures were performed internal fixation with absorbable rib-connecting-pins under epidural anesthesia. All cases were followed up for 1 to 12 months, with an average of 5 months. All fractures were achieved healing in 3 to 6 months after the operation and were not found chest wall deformity. Absorbable rib-connecting-pins fixation is a simple and effective method and worthies recommending to perform operation for the appropriate cases with multiple rib fractures.

  9. An ion beam facility based on a 3 MV tandetron accelerator in Sichuan University, China

    NASA Astrophysics Data System (ADS)

    Han, Jifeng; An, Zhu; Zheng, Gaoqun; Bai, Fan; Li, Zhihui; Wang, Peng; Liao, Xiaodong; Liu, Mantian; Chen, Shunli; Song, Mingjiang; Zhang, Jun

    2018-03-01

    A new ion beam facility based on a 3 MV tandetron accelerator system has been installed in Sichuan University, China. The facility was developed by High Voltage Engineering Europa and consists of three high-energy beam lines including the ion beam analysis, ion implantation and nuclear physics experiment end stations, respectively. The terminal voltage stability of the accelerator is better than ±30 V, and the brightness of the proton beam is approximately 5.06 A/rad2/m2/eV. The system demonstrates a great application potential in fields such as nuclear, material and environmental studies.

  10. Cough-induced rib fractures.

    PubMed

    Sano, Atsushi; Tashiro, Ken; Fukuda, Tsutomu

    2015-10-01

    Occasionally, patients who complain of chest pain after the onset of coughing are diagnosed with rib fractures. We investigated the characteristics of cough-induced rib fractures. Between April 2008 and December 2013, 17 patients were referred to our hospital with chest pain after the onset of coughing. Rib radiography was performed, focusing on the location of the chest pain. When the patient had other signs and symptoms such as fever or persistent cough, computed tomography of the chest was carried out. We analyzed the data retrospectively. Rib fractures were found in 14 of the 17 patients. The age of the patients ranged from 14 to 86 years (median 39.5 years). Ten patients were female and 4 were male. Three patients had chronic lung disease. There was a single rib fracture in 9 patients, and 5 had two or more fractures. The middle and lower ribs were the most commonly involved; the 10th rib was fractured most frequently. Cough-induced rib fractures occur in every age group regardless of the presence or absence of underlying disease. Since rib fractures often occur in the lower and middle ribs, rib radiography is useful for diagnosis. © The Author(s) 2015.

  11. Clinical and Radiologic Predictive Factors of Rib Fractures in Outpatients With Chest Pain.

    PubMed

    Zhang, Liang; McMahon, Colm J; Shah, Samir; Wu, Jim S; Eisenberg, Ronald L; Kung, Justin W

    To identify the clinical and radiologic predictive factors of rib fractures in stable adult outpatients presenting with chest pain and to determine the utility of dedicated rib radiographs in this population of patients. Following Institutional Review Board approval, we performed a retrospective review of 339 consecutive cases in which a frontal chest radiograph and dedicated rib series had been obtained for chest pain in the outpatient setting. The frontal chest radiograph and dedicated rib series were sequentially reviewed in consensus by two fellowship-trained musculoskeletal radiologists blinded to the initial report. The consensus interpretation of the dedicated rib series was used as the gold standard. Multiple variable logistic regression analysis assessed clinical and radiological factors associated with rib fractures. Fisher exact test was used to assess differences in medical treatment between the 2 groups. Of the 339 patients, 53 (15.6%) had at least 1 rib fracture. Only 20 of the 53 (37.7%) patients' fractures could be identified on the frontal chest radiograph. The frontal chest radiograph had a sensitivity of 38% and specificity of 100% when using the rib series as the reference standard. No pneumothorax, new mediastinal widening or pulmonary contusion was identified. Multiple variable logistic regression analysis of clinical factors associated with the presence of rib fractures revealed a significant association of trauma history (odds ratio 5.7 [p < 0.05]) and age ≥40 (odds radio 3.1 [p < 0.05]). Multiple variable logistic regression analysis of radiographic factors associated with rib fractures in this population demonstrated a significant association of pleural effusion with rib fractures (odds ratio 18.9 [p < 0.05]). Patients with rib fractures received narcotic analgesia in 47.2% of the cases, significantly more than those without rib fractures (21.3%, p < 0.05). None of the patients required hospitalization. In the stable outpatient setting, rib fractures have a higher association with a history of minor trauma and age ≥40 in the adult population. Radiographic findings associated with rib fractures include pleural effusion. The frontal chest radiograph alone has low sensitivity in detecting rib fractures. The dedicated rib series detected a greater number of rib fractures. Although no patients required hospitalization, those with rib fractures were more likely to receive narcotic analgesia. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Numerical investigations of rib fracture failure models in different dynamic loading conditions.

    PubMed

    Wang, Fang; Yang, Jikuang; Miller, Karol; Li, Guibing; Joldes, Grand R; Doyle, Barry; Wittek, Adam

    2016-01-01

    Rib fracture is one of the most common thoracic injuries in vehicle traffic accidents that can result in fatalities associated with seriously injured internal organs. A failure model is critical when modelling rib fracture to predict such injuries. Different rib failure models have been proposed in prediction of thorax injuries. However, the biofidelity of the fracture failure models when varying the loading conditions and the effects of a rib fracture failure model on prediction of thoracic injuries have been studied only to a limited extent. Therefore, this study aimed to investigate the effects of three rib failure models on prediction of thoracic injuries using a previously validated finite element model of the human thorax. The performance and biofidelity of each rib failure model were first evaluated by modelling rib responses to different loading conditions in two experimental configurations: (1) the three-point bending on the specimen taken from rib and (2) the anterior-posterior dynamic loading to an entire bony part of the rib. Furthermore, the simulation of the rib failure behaviour in the frontal impact to an entire thorax was conducted at varying velocities and the effects of the failure models were analysed with respect to the severity of rib cage damages. Simulation results demonstrated that the responses of the thorax model are similar to the general trends of the rib fracture responses reported in the experimental literature. However, they also indicated that the accuracy of the rib fracture prediction using a given failure model varies for different loading conditions.

  13. The TRIUMF nuclear structure program and TIGRESS

    NASA Astrophysics Data System (ADS)

    Garrett, P. E.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Becker, J. A.; Boston, A. J.; Boston, H. C.; Chakrawarthy, R. S.; Churchman, R.; Cline, D.; Cooper, R. J.; Cross, D.; Dashdorj, D.; Demand, G. A.; Dimmock, M. R.; Drake, T.; Finlay, P.; Gagnon, K.; Gallant, A. T.; Green, K. L.; Grint, A. N.; Grinyer, G. F.; Hackman, G.; Harkness, L. J.; Hayes, A. B.; Kanungo, R.; Kulp, W. D.; Leach, K. G.; Lee, G.; Leslie, J. R.; Maharaj, R.; Martin, J.-P.; Mattoon, C.; Mills, W. J.; Morton, A. C.; Nelson, L.; Newman, O.; Nolan, P. J.; Padilla-Rodal, E.; Pearson, C. J.; Phillips, A. A.; Porter-Peden, M.; Ressler, J. J.; Ruiz, C.; Sarazin, F.; Schumaker, M. A.; Scraggs, D. P.; Strange, M. D.; Subramanian, M.; Svensson, C. E.; Waddington, J. C.; Wan, J.; Whitbeck, A.; Williams, S. J.; Wood, J. L.; Wong, J. C.; Wu, C. Y.; Zganjar, E. F.

    2007-08-01

    The isotope separator and accelerator (ISAC) facility located at the TRIUMF laboratory in Vancouver, Canada, is one of the world's most advanced isotope separator on-line-type radioactive ion beam facilities. An extensive γ-ray spectroscopy programme at ISAC is centred around two major research facilities: (i) the 8π γ-ray spectrometer for β-delayed γ-ray spectroscopy experiments with the low-energy beams from ISAC-I, and (ii) the next generation TRIUMF-ISAC gamma-ray escape suppressed spectrometer (TIGRESS) for in-beam experiments with the accelerated radioactive-ion beams. An overview of these facilities and recent results from the diverse programme of nuclear structure and fundamental interaction studies they support is presented.

  14. Shape accuracy optimization for cable-rib tension deployable antenna structure with tensioned cables

    NASA Astrophysics Data System (ADS)

    Liu, Ruiwei; Guo, Hongwei; Liu, Rongqiang; Wang, Hongxiang; Tang, Dewei; Song, Xiaoke

    2017-11-01

    Shape accuracy is of substantial importance in deployable structures as the demand for large-scale deployable structures in various fields, especially in aerospace engineering, increases. The main purpose of this paper is to present a shape accuracy optimization method to find the optimal pretensions for the desired shape of cable-rib tension deployable antenna structure with tensioned cables. First, an analysis model of the deployable structure is established by using finite element method. In this model, geometrical nonlinearity is considered for the cable element and beam element. Flexible deformations of the deployable structure under the action of cable network and tensioned cables are subsequently analyzed separately. Moreover, the influence of pretension of tensioned cables on natural frequencies is studied. Based on the results, a genetic algorithm is used to find a set of reasonable pretension and thus minimize structural deformation under the first natural frequency constraint. Finally, numerical simulations are presented to analyze the deployable structure under two kinds of constraints. Results show that the shape accuracy and natural frequencies of deployable structure can be effectively improved by pretension optimization.

  15. Triode carbon nanotube field emission display using barrier rib structure and manufacturing method thereof

    DOEpatents

    Han, In-taek; Kim, Jong-min

    2003-01-01

    A triode carbon nanotube field emission display (FED) using a barrier rib structure and a manufacturing method thereof are provided. In a triode carbon nanotube FED employing barrier ribs, barrier ribs are formed on cathode lines by a screen printing method, a mesh structure is mounted on the barrier ribs, and a spacer is inserted between the barrier ribs through slots of the mesh structure, thereby stably fixing the mesh structure and the spacer within a FED panel due to support by the barrier ribs.

  16. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.

    PubMed

    Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven

    2010-05-01

    This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.

  17. Are first rib fractures a marker for other life-threatening injuries in patients with major trauma? A cohort study of patients on the UK Trauma Audit and Research Network database

    PubMed Central

    Sammy, Ian Ayenga; Chatha, Hridesh; Lecky, Fiona; Bouamra, Omar; Fragoso-Iñiguez, Marisol; Sattout, Abdo; Hickey, Michael; Edwards, John E

    2017-01-01

    Background First rib fractures are considered indicators of increased morbidity and mortality in major trauma. However, this has not been definitively proven. With an increased use of CT and the potential increase in detection of first rib fractures, re-evaluation of these injuries as a marker for life-threatening injuries is warranted. Methods Patients sustaining rib fractures between January 2012 and December 2013 were investigated using data from the UK Trauma Audit and Research Network. The prevalence of life-threatening injuries was compared in patients with first rib fractures and those with other rib fractures. Multivariate logistic regression was performed to determine the association between first rib fractures, injury severity, polytrauma and mortality. Results There were 1683 patients with first rib fractures and 8369 with fractures of other ribs. Life-threatening intrathoracic and extrathoracic injuries were more likely in patients with first rib fractures. The presence of first rib fractures was a significant predictor of injury severity (Injury Severity Score >15) and polytrauma, independent of mechanism of injury, age and gender with an adjusted OR of 2.64 (95% CI 2.33 to 3.00) and 2.01 (95% CI 1.80 to 2.25), respectively. Risk-adjusted mortality was the same in patients with first rib fractures and those with other rib fractures (adjusted OR 0.97, 95% CI 0.79 to 1.19). Conclusion First rib fractures are a marker of life-threatening injuries in major trauma, though they do not independently increase mortality. Management of patients with first rib fractures should focus on identification and treatment of associated life-threatening injuries. PMID:28119351

  18. Proposed BISOL Facility - a Conceptual Design

    NASA Astrophysics Data System (ADS)

    Ye, Yanlin

    2018-05-01

    In China, a new large-scale nuclear-science research facility, namely the "Beijing Isotope-Separation-On-Line neutron-rich beam facility (BISOL)", has been proposed and reviewed by the governmental committees. This facility aims at both basic science and application goals, and is based on a double-driver concept. On the basic science side, the radioactive ion beams produced from the ISOL device, driven by a research reactor or by an intense deuteron-beam ac- celerator, will be used to study the new physics and technologies at the limit of the nuclear stability in the medium mass region. On the other side regarding to the applications, the facility will be devoted to the material research asso- ciated with the nuclear energy system, by using typically the intense neutron beams produced from the deuteron-accelerator driver. The initial design will be outlined in this report.

  19. Segmentation of ribs in digital chest radiographs

    NASA Astrophysics Data System (ADS)

    Cong, Lin; Guo, Wei; Li, Qiang

    2016-03-01

    Ribs and clavicles in posterior-anterior (PA) digital chest radiographs often overlap with lung abnormalities such as nodules, and cause missing of these abnormalities, it is therefore necessary to remove or reduce the ribs in chest radiographs. The purpose of this study was to develop a fully automated algorithm to segment ribs within lung area in digital radiography (DR) for removal of the ribs. The rib segmentation algorithm consists of three steps. Firstly, a radiograph was pre-processed for contrast adjustment and noise removal; second, generalized Hough transform was employed to localize the lower boundary of the ribs. In the third step, a novel bilateral dynamic programming algorithm was used to accurately segment the upper and lower boundaries of ribs simultaneously. The width of the ribs and the smoothness of the rib boundaries were incorporated in the cost function of the bilateral dynamic programming for obtaining consistent results for the upper and lower boundaries. Our database consisted of 93 DR images, including, respectively, 23 and 70 images acquired with a DR system from Shanghai United-Imaging Healthcare Co. and from GE Healthcare Co. The rib localization algorithm achieved a sensitivity of 98.2% with 0.1 false positives per image. The accuracy of the detected ribs was further evaluated subjectively in 3 levels: "1", good; "2", acceptable; "3", poor. The percentages of good, acceptable, and poor segmentation results were 91.1%, 7.2%, and 1.7%, respectively. Our algorithm can obtain good segmentation results for ribs in chest radiography and would be useful for rib reduction in our future study.

  20. Automated System Calibration and Verification of the Position Measurements for the Los Alamos Isotope Production Facility and the Switchyard Kicker Facilities

    NASA Astrophysics Data System (ADS)

    Barr, D.; Gilpatrick, J. D.; Martinez, D.; Shurter, R. B.

    2004-11-01

    The Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory has constructed both an Isotope Production Facility (IPF) and a Switchyard Kicker (XDK) as additions to the H+ and H- accelerator. These additions contain eleven Beam Position Monitors (BPMs) that measure the beam's position throughout the transport. The analog electronics within each processing module determines the beam position using the log-ratio technique. For system reliability, calibrations compensate for various temperature drifts and other imperfections in the processing electronics components. Additionally, verifications are periodically implemented by a PC running a National Instruments LabVIEW virtual instrument (VI) to verify continued system and cable integrity. The VI communicates with the processor cards via a PCI/MXI-3 VXI-crate communication module. Previously, accelerator operators performed BPM system calibrations typically once per day while beam was explicitly turned off. One of this new measurement system's unique achievements is its automated calibration and verification capability. Taking advantage of the pulsed nature of the LANSCE-facility beams, the integrated electronics hardware and VI perform calibration and verification operations between beam pulses without interrupting production beam delivery. The design, construction, and performance results of the automated calibration and verification portion of this position measurement system will be the topic of this paper.

  1. Numerical simulations of heat transfer distribution of a two-pass square channel with V-rib turbulator and bleed holes

    NASA Astrophysics Data System (ADS)

    Kumar, Sourabh; Amano, R. S.; Lucci, Jose Martinez

    2013-08-01

    The blade tip region in gas turbine encounters high thermal loads due to temperature difference and hence efforts for high durability and safe operations are essential. Improved and robust methods of cooling are required to downgrade heat transfer rate to turbine blades. The blade tip regions, which are exposed to high gas flow, suffers high local thermal load which are due to external tip leakage. Jet impingement, pin cooling etc. are techniques used for cooling blades. A more usual way is to use serpentine passage with 180-degree turn. In this study, numerical simulation of heat transfer distribution of a two-pass square channel with rib turbulators and bleed holes were done. Periodical rib turbulators and bleed holes were used in the channel. The ribs arrangement were 60 degree V rib, 60 degree inverted V ribs, combination of 60 degree V rib at inlet and 60 inverted V rib at outlet section and combination of Inverted V at inlet and V rib at the outlet. The results were numerically computed using Fluent with Reynolds number of 12,500 and 28,500. Turbulence models used for computations were k-ω-SST and RSM. Temperature based and shear stress based techniques were used for heat transfer distribution prediction. The results for 60 degree V rib, 60 degree inverted V ribs were compared with the experimental results for validation of the results obtained. Detailed distribution shows distinctive peaks in heat transfer around bleed holes and rib turbulator. Comparisons of the overall performance of the models with different orientation of rib turbulator are presented. It is found that due to the combination of 60 degree inverted V rib in inlet and 60 V rib in outlet with bleed holes provides better heat treatment. It is suggested that the use of rib turbulator with bleed holes provides suitable for augmenting blade cooling to achieve an optimal balance between thermal and mechanical design requirements.

  2. Epidemiology of rib fractures in older men: Osteoporotic Fractures in Men (MrOS) prospective cohort study.

    PubMed

    Barrett-Connor, Elizabeth; Nielson, Carrie M; Orwoll, Eric; Bauer, Douglas C; Cauley, Jane A

    2010-03-15

    To study the causes and consequences of radiologically confirmed rib fractures (seldom considered in the context of osteoporosis) in community dwelling older men. Prospective cohort study (Osteoporotic Fractures in Men (MrOS) Study). 5995 men aged 65 or over recruited in 2000-2 from six US sites; 99% answered mailed questionnaires about falls and fractures every four months for a mean 6.2 (SD 1.3) year follow-up. New fractures validated by radiology reports; multivariate Cox proportional hazard ratios were used to evaluate factors independently associated with time to incident rib fracture; associations between baseline rib fracture and incident hip and wrist fracture were also evaluated. The incidence of rib fracture was 3.5/1000 person years, and 24% (126/522) of all incident non-spine fractures were rib fractures. Nearly half of new rib fractures (48%; n=61) followed falling from standing height or lower. Independent risk factors for an incident rib fracture were age 80 or above, low bone density, difficulty with instrumental activities of daily living, and a baseline history of rib/chest fracture. Men with a history of rib/chest fracture had at least a twofold increased risk of an incident rib fracture (adjusted hazard ratio 2.71, 95% confidence interval 1.86 to 3.95), hip fracture (2.05, 1.33 to 3.15), and wrist fracture (2.06, 1.14 to 3.70). Only 14/82 of men reported being treated with bone specific drugs after their incident rib fracture. Rib fracture, the most common incident clinical fracture in men, was associated with classic risk markers for osteoporosis, including old age, low hip bone mineral density, and history of fracture. A history of rib fracture predicted a more than twofold increased risk of future fracture of the rib, hip, or wrist, independent of bone density and other covariates. Rib fractures should be considered to be osteoporotic fractures in the evaluation of older men for treatment to prevent future fracture.

  3. External beam boost versus interstitial high-dose-rate brachytherapy boost in the adjuvant radiotherapy following breast-conserving therapy in early-stage breast cancer: a dosimetric comparison

    PubMed Central

    Melchert, Corinna; Kovács, György

    2016-01-01

    Purpose This study aims to compare the dosimetric data of local tumor's bed dose escalation (boost) with photon beams (external beam radiation therapy – EBRT) versus high-dose-rate interstitial brachytherapy (HDR-BT) after breast-conserving treatment in women with early-stage breast cancer. Material and methods We analyzed the treatment planning data of 136 irradiated patients, treated between 2006 and 2013, who underwent breast-conserving surgery and adjuvant whole breast irradiation (WBI; 50.4 Gy) and boost (HDR-BT: 10 Gy in one fraction [n = 36]; EBRT: 10 Gy in five fractions [n = 100]). Organs at risk (OAR; heart, ipsilateral lung, skin, most exposed rib segment) were delineated. Dosimetric parameters were calculated with the aid of dose-volume histograms (DVH). A non-parametric test was performed to compare the two different boost forms. Results There was no difference for left-sided cancers regarding the maximum dose to the heart (HDR-BT 29.8% vs. EBRT 29.95%, p = 0.34). The maximum doses to the other OAR were significantly lower for HDR-BT (Dmax lung 47.12% vs. 87.7%, p < 0.01; rib 61.17% vs. 98.5%, p < 0.01; skin 57.1% vs. 94.75%, p < 0.01; in the case of right-sided breast irradiation, dose of the heart 6.00% vs. 16.75%, p < 0.01). Conclusions Compared to EBRT, local dose escalation with HDR-BT presented a significant dose reduction to the investigated OAR. Only left-sided irradiation showed no difference regarding the maximum dose to the heart. Reducing irradiation exposure to OAR could result in a reduction of long-term side effects. Therefore, from a dosimetric point of view, an interstitial boost complementary to WBI via EBRT seems to be more advantageous in the adjuvant radiotherapy of breast cancer. PMID:27648082

  4. Rib Fracture Diagnosis in the Panscan Era.

    PubMed

    Murphy, Charles E; Raja, Ali S; Baumann, Brigitte M; Medak, Anthony J; Langdorf, Mark I; Nishijima, Daniel K; Hendey, Gregory W; Mower, William R; Rodriguez, Robert M

    2017-12-01

    With increased use of chest computed tomography (CT) in trauma evaluation, traditional teachings in regard to rib fracture morbidity and mortality may no longer be accurate. We seek to determine rates of rib fracture observed on chest CT only; admission and mortality of patients with isolated rib fractures, rib fractures observed on CT only, and first or second rib fractures; and first or second rib fracture-associated great vessel injury. We conducted a planned secondary analysis of 2 prospectively enrolled cohorts of the National Emergency X-Radiography Utilization Study chest studies, which evaluated patients with blunt trauma who were older than 14 years and received chest imaging in the emergency department. We defined rib fractures and other thoracic injuries according to CT reports and followed patients through their hospital course to determine outcomes. Of 8,661 patients who had both chest radiograph and chest CT, 2,071 (23.9%) had rib fractures, and rib fractures were observed on chest CT only in 1,368 cases (66.1%). Rib fracture patients had higher admission rates (88.7% versus 45.8%; mean difference 42.9%; 95% confidence interval [CI] 41.4% to 44.4%) and mortality (5.6% versus 2.7%; mean difference 2.9%; 95% CI 1.8% to 4.0%) than patients without rib fracture. The mortality of patients with rib fracture observed on chest CT only was not statistically significantly different from that of patients with fractures also observed on chest radiograph (4.8% versus 5.7%; mean difference -0.9%; 95% CI -3.1% to 1.1%). Patients with first or second rib fractures had significantly higher mortality (7.4% versus 4.1%; mean difference 3.3%; 95% CI 0.2% to 7.1%) and prevalence of concomitant great vessel injury (2.8% versus 0.6%; mean difference 2.2%; 95% CI 0.6% to 4.9%) than patients with fractures of ribs 3 to 12, and the odds ratio of great vessel injury with first or second rib fracture was 4.4 (95% CI 1.8 to 10.4). Under trauma imaging protocols that commonly incorporate chest CT, two thirds of rib fractures were observed on chest CT only. Patients with rib fractures had higher admission rates and mortality than those without rib fractures. First or second rib fractures were associated with significantly higher mortality and great vessel injury. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  5. Case report: clinical and postmortem findings in four cows with rib fracture.

    PubMed

    Braun, Ueli; Warislohner, Sonja; Hetzel, Udo; Nuss, Karl

    2017-02-06

    Published reports of rib fractures in adult cattle are limited to the occurrence of chronic rib swellings caused by calluses, which are unremarkable from a clinical standpoint, whereas studies identifying clinical signs of rib fractures were not found in a literature search. This report describes the clinical and postmortem findings in four cows with rib fractures. The 13th rib was fractured in three cows and the 11th rib in the remaining cow; three fractures were on the right and one on the left side. Clinical and postmortem findings varied considerably, and percussion of the rib cage elicited a pain response in only one cow. One cow had generalised peritonitis because of perforation of the rumen by the fractured rib. One cow was recumbent because of pain and became a downer cow, and two other cows had bronchopneumonia, which was a sequel to osteomyelitis of the fracture site in one. In the absence of a history of trauma, the diagnosis of rib fracture based on clinical signs alone is difficult. Although rib fractures undoubtedly are very painful, the four cases described in this report suggest that they are difficult to diagnose in cattle because associated clinical signs are nonspecific.

  6. Overview of laser systems for the Orion facility at the AWE.

    PubMed

    Hopps, Nicholas; Danson, Colin; Duffield, Stuart; Egan, David; Elsmere, Stephen; Girling, Mark; Harvey, Ewan; Hillier, David; Norman, Michael; Parker, Stefan; Treadwell, Paul; Winter, David; Bett, Thomas

    2013-05-20

    The commissioning of the Orion laser facility at the Atomic Weapons Establishment (AWE) in the UK has recently been completed. The facility is a twelve beam Nd:glass-based system for studying high energy density physics. It consists of ten frequency-tripled beam-lines operating with nanosecond pulses, synchronized with two beam-lines with subpicosecond pulses, each capable of delivering 500 J to target. One of the short pulse beams has the option of frequency doubling, at reduced aperture, to yield up to 100 J at 527 nm in a subpicosecond pulse with high temporal contrast. An extensive array of target diagnostics is provided. This article describes the laser design and commissioning and presents key performance data of the facility's laser systems.

  7. Monte Carlo simulations for the shielding of the future high-intensity accelerator facility FAIR at GSI.

    PubMed

    Radon, T; Gutermuth, F; Fehrenbacher, G

    2005-01-01

    The Gesellschaft für Schwerionenforschung (GSI) is planning a significant expansion of its accelerator facilities. Compared to the present GSI facility, a factor of 100 in primary beam intensities and up to a factor of 10,000 in secondary radioactive beam intensities are key technical goals of the proposal. The second branch of the so-called Facility for Antiproton and Ion Research (FAIR) is the production of antiprotons and their storage in rings and traps. The facility will provide beam energies a factor of approximately 15 higher than presently available at the GSI for all ions, from protons to uranium. The shielding design of the synchrotron SIS 100/300 is shown exemplarily by using Monte Carlo calculations with the FLUKA code. The experimental area serving the investigation of compressed baryonic matter is analysed in the same way. In addition, a dose comparison is made for an experimental area operated with medium energy heavy-ion beams. Here, Monte Carlo calculations are performed by using either heavy-ion primary particles or proton beams with intensities scaled by the mass number of the corresponding heavy-ion beam.

  8. Simulations for the future converter of the e-linac for the TRIUMF ARIEL facility

    NASA Astrophysics Data System (ADS)

    Lebois, M.; Bricault, P.

    2011-09-01

    In the next years, TRIUMF activity will be focused on building a new facility to produce very intense neutron rich radioactive ion beams. Unlike others ISOL facilities, the e-linac primary beam, that will induce the fission, is an intense electron beam (50 MeV energy and 10 mA intensity). This challenging choice, which make this installation unique, despite the ALTO facility, makes an average fission rate of 1013-14fissions/s in the target.This beam is sent on an uranium carbide target (UCx), but due to its power, it is essential to insert a "converter" on the beam path to avoid a target overheating. The purpose of this converter is to convert electrons into Bremsstralhung radiation. The γ rays produce excite the dipole resonance of 23892U (15 MeV) inducing fission. Energy deposition, fission rate and thermal behavior were simulated using Monte Carlo techniques are presented in this paper

  9. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    NASA Astrophysics Data System (ADS)

    Guo, J.; Bücherl, T.; Zou, Y.; Guo, Z.

    2011-09-01

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  10. Nineth Rib Syndrome after 10(th) Rib Resection.

    PubMed

    Yu, Hyun Jeong; Jeong, Yu Sub; Lee, Dong Hoon; Yim, Kyoung Hoon

    2016-07-01

    The 12(th) rib syndrome is a disease that causes pain between the upper abdomen and the lower chest. It is assumed that the impinging on the nerves between the ribs causes pain in the lower chest, upper abdomen, and flank. A 74-year-old female patient visited a pain clinic complaining of pain in her back, and left chest wall at a 7 on the 0-10 Numeric Rating scale (NRS). She had a lateral fixation at T12-L2, 6 years earlier. After the operation, she had multiple osteoporotic compression fractures. When the spine was bent, the patient complained about a sharp pain in the left mid-axillary line and radiating pain toward the abdomen. On physical examination, the 10(th) rib was not felt, and an image of the rib-cage confirmed that the left 10(th) rib was severed. When applying pressure from the legs to the 9(th) rib of the patient, pain was reproduced. Therefore, the patient was diagnosed with 9(th) rib syndrome, and ultrasound-guided 9(th) and 10(th) intercostal nerve blocks were performed around the tips of the severed 10(th) rib. In addition, local anesthetics with triamcinolone were administered into the muscles beneath the 9(th) rib at the point of the greatest tenderness. The patient's pain was reduced to NRS 2 point. In this case, it is suspected that the patient had a partial resection of the left 10(th) rib in the past, and subsequent compression fractures at T8 and T9 led to the deformation of the rib cage, causing the tip of the remaining 10(th) rib to impinge on the 9(th) intercostal nerves, causing pain.

  11. A rib-specific multimodal registration algorithm for fused unfolded rib visualization using PET/CT

    NASA Astrophysics Data System (ADS)

    Kaftan, Jens N.; Kopaczka, Marcin; Wimmer, Andreas; Platsch, Günther; Declerck, Jérôme

    2014-03-01

    Respiratory motion affects the alignment of PET and CT volumes from PET/CT examinations in a non-rigid manner. This becomes particularly apparent if reviewing fine anatomical structures such as ribs when assessing bone metastases, which frequently occur in many advanced cancers. To make this routine diagnostic task more efficient, a fused unfolded rib visualization for 18F-NaF PET/CT is presented. It allows to review the whole rib cage in a single image. This advanced visualization is enabled by a novel rib-specific registration algorithm that rigidly optimizes the local alignment of each individual rib in both modalities based on a matched filter response function. More specifically, rib centerlines are automatically extracted from CT and subsequently individually aligned to the corresponding bone-specific PET rib uptake pattern. The proposed method has been validated on 20 PET/CT scans acquired at different clinical sites. It has been demonstrated that the presented rib- specific registration method significantly improves the rib alignment without having to run complex deformable registration algorithms. At the same time, it guarantees that rib lesions are not further deformed, which may otherwise affect quantitative measurements such as SUVs. Considering clinically relevant distance thresholds, the centerline portion with good alignment compared to the ground truth improved from 60:6% to 86:7% after registration while approximately 98% can be still considered as acceptably aligned.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halavanau, A.; Hyun, J.; Mihalcea, D.

    A photocathode, immersed in solenoidal magnetic field, can produce canonical-angular-momentum (CAM) dominated or “magnetized” electron beams. Such beams have an application in electron cooling of hadron beams and can also be uncoupled to yield asymmetric-emittance (“flat”) beams. In the present paper we explore the possibilities of the flat beam generation at Fermilab’s Accelerator Science and Technology (FAST) facility. We present optimization of the beam flatness and four-dimensional transverse emittance and investigate the mapping and its limitations of the produced eigen-emittances to conventional emittances using a skew-quadrupole channel. Possible application of flat beams at the FAST facility are also discussed.

  13. Model based rib-cage unfolding for trauma CT

    NASA Astrophysics Data System (ADS)

    von Berg, Jens; Klinder, Tobias; Lorenz, Cristian

    2018-03-01

    A CT rib-cage unfolding method is proposed that does not require to determine rib centerlines but determines the visceral cavity surface by model base segmentation. Image intensities are sampled across this surface that is flattened using a model based 3D thin-plate-spline registration. An average rib centerline model projected onto this surface serves as a reference system for registration. The flattening registration is designed so that ribs similar to the centerline model are mapped onto parallel lines preserving their relative length. Ribs deviating from this model appear deviating from straight parallel ribs in the unfolded view, accordingly. As the mapping is continuous also the details in intercostal space and those adjacent to the ribs are rendered well. The most beneficial application area is Trauma CT where a fast detection of rib fractures is a crucial task. Specifically in trauma, automatic rib centerline detection may not be guaranteed due to fractures and dislocations. The application by visual assessment on the large public LIDC data base of lung CT proved general feasibility of this early work.

  14. ELECTRON BEAM SHAPING AND ITS APPLICATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halavanau, Aliaksei

    Transverse and longitudinal electron beam shaping is a crucial part of high-brightness electron accelerator operations. In this dissertation, we report on the corresponding beam dynamics research conducted at Fermilab Accelerator Science and Technology facility (FAST) and Argonne Wakeeld Accelerator (AWA). We demonstrate an experimental method for spatial laser and electron beam shaping using microlens arrays (MLAs) at a photoinjector facility. Such a setup was built at AWA and resulted in transverse emittance reduction by a factor of 2. We present transverse emittance partitioning methods that were recently employed at FAST facility. A strongly coupled electron beam was generated in anmore » axial magnetic eld and accelerated in 1.3 GHz SRF cavities to 34 MeV. It was then decoupled in Round-To-Flat beam transformer and beams with emittance asymmetry ratio of 100 were generated. We introduce the new methods of measuring electron beam canonical angular momentum, beam transformer optimization and beam image analysis. We also describe a potential longitudinal space-charge amplier setup for FAST high-energy beamline. As an outcome, a broadband partially coherent radiation in the UV range could be generated.« less

  15. A novel ex vivo model of compressive immature rib fractures at pathophysiological rates of loading.

    PubMed

    Beadle, Nicola; Burnett, Timothy L; Hoyland, Judith A; Sherratt, Michael J; Freemont, Anthony J

    2015-11-01

    Compressive rib fractures are considered to be indicative of non-accidental injury (NAI) in infants, which is a significant and growing issue worldwide. The diagnosis of NAI is often disputed in a legal setting, and as a consequence there is a need to model such injuries ex vivo in order to characterise the forces required to produce non-accidental rib fractures. However, current models are limited by type of sample, loading method and rate of loading. Here, we aimed to: i) develop a loading system for inducing compressive fractures in whole immature ribs that is more representative of the physiological conditions and mechanism of injury employed in NAI and ii) assess the influence of loading rate and rib geometry on the mechanical performance of the tissue. Porcine ribs (5-6 weeks of age) from 12 animals (n=8 ribs/animal) were subjected to axial compressive load directed through the anterior-posterior rib axis at loading rates of 1, 30, 60 or 90 mm/s. Key mechanical parameters (including peak load, load and percentage deformation to failure and effective stiffness) were quantified from the load-displacement curves. Measurements of the rib length, thickness at midpoint, distance between anterior and posterior extremities, rib curvature and fracture location were determined from radiographs. This loading method typically produced incomplete fractures around the midpoint of the ribs, with 87% failing in this manner; higher loads and less deformation were required for ribs to completely fracture through both cortices. Loading rate, within the range of 1-90 mm/s, did not significantly affect any key mechanical parameters of the ribs. Load-displacement curves displaying characteristic and quantifiable features were produced for 90% of the ribs tested, and multiple regression analyses indicate that, in addition to the geometrical variables, there are other factors such as the micro- and nano-structure that influence the measured mechanical data. A reproducible method of inducing fractures in a consistent location in immature porcine ribs has been successfully developed. Fracture appearance may be indicative of the amount of load and deformation that produced the fracture, which is an important finding for NAI, where knowledge of the aetiology of fractures is vital. Characteristic rib behaviour independent of loading rate and, to an extent, rib geometry has been demonstrated, allowing further investigation into how the complex micro- and nano-structure of immature ribs influences the mechanical performance under compressive load. This research will ultimately enable improved characterisation of the loading pattern involved in non-accidental rib fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Heat transfer and friction characteristics of the microfluidic heat sink with variously-shaped ribs for chip cooling.

    PubMed

    Wang, Gui-Lian; Yang, Da-Wei; Wang, Yan; Niu, Di; Zhao, Xiao-Lin; Ding, Gui-Fu

    2015-04-22

    This paper experimentally and numerically investigated the heat transfer and friction characteristics of microfluidic heat sinks with variously-shaped micro-ribs, i.e., rectangular, triangular and semicircular ribs. The micro-ribs were fabricated on the sidewalls of microfluidic channels by a surface-micromachining micro-electro-mechanical system (MEMS) process and used as turbulators to improve the heat transfer rate of the microfluidic heat sink. The results indicate that the utilizing of micro-ribs provides a better heat transfer rate, but also increases the pressure drop penalty for microchannels. Furthermore, the heat transfer and friction characteristics of the microchannels are strongly affected by the rib shape. In comparison, the triangular ribbed microchannel possesses the highest Nusselt number and friction factor among the three rib types.

  17. Are first rib fractures a marker for other life-threatening injuries in patients with major trauma? A cohort study of patients on the UK Trauma Audit and Research Network database.

    PubMed

    Sammy, Ian Ayenga; Chatha, Hridesh; Lecky, Fiona; Bouamra, Omar; Fragoso-Iñiguez, Marisol; Sattout, Abdo; Hickey, Michael; Edwards, John E

    2017-04-01

    First rib fractures are considered indicators of increased morbidity and mortality in major trauma. However, this has not been definitively proven. With an increased use of CT and the potential increase in detection of first rib fractures, re-evaluation of these injuries as a marker for life-threatening injuries is warranted. Patients sustaining rib fractures between January 2012 and December 2013 were investigated using data from the UK Trauma Audit and Research Network. The prevalence of life-threatening injuries was compared in patients with first rib fractures and those with other rib fractures. Multivariate logistic regression was performed to determine the association between first rib fractures, injury severity, polytrauma and mortality. There were 1683 patients with first rib fractures and 8369 with fractures of other ribs. Life-threatening intrathoracic and extrathoracic injuries were more likely in patients with first rib fractures. The presence of first rib fractures was a significant predictor of injury severity (Injury Severity Score >15) and polytrauma, independent of mechanism of injury, age and gender with an adjusted OR of 2.64 (95% CI 2.33 to 3.00) and 2.01 (95% CI 1.80 to 2.25), respectively. Risk-adjusted mortality was the same in patients with first rib fractures and those with other rib fractures (adjusted OR 0.97, 95% CI 0.79 to 1.19). First rib fractures are a marker of life-threatening injuries in major trauma, though they do not independently increase mortality. Management of patients with first rib fractures should focus on identification and treatment of associated life-threatening injuries. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) [year]. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Wire Chambers and Cherenkov Detectors at Fermilab Test Beam Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tame Narvaez, Karla

    2017-01-01

    Fermilab Test Beam Facility (FTBF) is dedicated to helping scientists test their prototypes. For this, FTBF has instrumentation that is very useful for the users. However, before a user can test a detector, it is necessary to ensure the facility has the characteristics they need. During this summer, we studied beam properties by collecting Cherenkov and wire chamber data. Analyzed data will be used for updating the general information that FTBF posts on a web page.

  19. The necessity of repeated assessment of imaging studies contained in medical records in medico-legal opinions.

    PubMed

    Borowska-Solonynko, A

    The paper presents two case reports of living victims, in which imaging studies of the chest conducted at a medical facility were an essential part of the medico-legal opinion. The first case was that of a young male hospitalized due to CT evidence of bilateral rib fractions, who claimed to have been assaulted by police officers. The other case was that of a six week old baby hospitalized due to chest X-ray evidence of right hand side rib fractions. The chest X-ray was performed due to one bruise found on the baby's forehead and two small bruises on the back, which gave rise to suspicions of child abuse. In both cases, expert witnesses in radiology definitively excluded the presence of any fractures. These cases indicate that a new assessment of imaging studies contained in medical records is needed. Expert opinions based solely on the description of imaging studies may result in grave consequences.

  20. The accelerator facility of the Heidelberg Ion-Beam Therapy Centre (HIT)

    NASA Astrophysics Data System (ADS)

    Peters, Andreas

    The following sections are included: * Introduction * Beam parameters * General layout of the HIT facility * The accelerator chain in detail * Operational aspects of a particle therapy facility * 24/7 accelerator operation at 335 days per year * Safety and regulatory aspects * Status and perspectives * References

  1. Rib fractures and death from deletion of osteoblast βcatenin in adult mice is rescued by corticosteroids.

    PubMed

    Duan, JinZhu; Lee, Yueh; Jania, Corey; Gong, Jucheng; Rojas, Mauricio; Burk, Laurel; Willis, Monte; Homeister, Jonathon; Tilley, Stephen; Rubin, Janet; Deb, Arjun

    2013-01-01

    Ribs are primarily made of cortical bone and are necessary for chest expansion and ventilation. Rib fractures represent the most common type of non-traumatic fractures in the elderly yet few studies have focused on the biology of rib fragility. Here, we show that deletion of βcatenin in Col1a2 expressing osteoblasts of adult mice leads to aggressive osteoclastogenesis with increased serum levels of the osteoclastogenic cytokine RANKL, extensive rib resorption, multiple spontaneous rib fractures and chest wall deformities. Within days of osteoblast specific βcatenin deletion, animals die from respiratory failure with a vanishing rib cage that is unable to sustain ventilation. Increased bone resorption is also observed in the vertebrae and femur. Treatment with the bisphosphonate pamidronate delayed but did not prevent death or associated rib fractures. In contrast, administration of the glucocorticoid dexamethasone decreased serum RANKL and slowed osteoclastogenesis. Dexamethasone preserved rib structure, prevented respiratory compromise and strikingly increased survival. Our findings provide a novel model of accelerated osteoclastogenesis, where deletion of osteoblast βcatenin in adults leads to rapid development of destructive rib fractures. We demonstrate the role of βcatenin dependent mechanisms in rib fractures and suggest that glucocorticoids, by suppressing RANKL, may have a role in treating bone loss due to aggressive osteoclastogenesis.

  2. Rib Fractures and Death from Deletion of Osteoblast βcatenin in Adult Mice Is Rescued by Corticosteroids

    PubMed Central

    Duan, JinZhu; Lee, Yueh; Jania, Corey; Gong, Jucheng; Rojas, Mauricio; Burk, Laurel; Willis, Monte; Homeister, Jonathon; Tilley, Stephen; Rubin, Janet; Deb, Arjun

    2013-01-01

    Ribs are primarily made of cortical bone and are necessary for chest expansion and ventilation. Rib fractures represent the most common type of non-traumatic fractures in the elderly yet few studies have focused on the biology of rib fragility. Here, we show that deletion of βcatenin in Col1a2 expressing osteoblasts of adult mice leads to aggressive osteoclastogenesis with increased serum levels of the osteoclastogenic cytokine RANKL, extensive rib resorption, multiple spontaneous rib fractures and chest wall deformities. Within days of osteoblast specific βcatenin deletion, animals die from respiratory failure with a vanishing rib cage that is unable to sustain ventilation. Increased bone resorption is also observed in the vertebrae and femur. Treatment with the bisphosphonate pamidronate delayed but did not prevent death or associated rib fractures. In contrast, administration of the glucocorticoid dexamethasone decreased serum RANKL and slowed osteoclastogenesis. Dexamethasone preserved rib structure, prevented respiratory compromise and strikingly increased survival. Our findings provide a novel model of accelerated osteoclastogenesis, where deletion of osteoblast βcatenin in adults leads to rapid development of destructive rib fractures. We demonstrate the role of βcatenin dependent mechanisms in rib fractures and suggest that glucocorticoids, by suppressing RANKL, may have a role in treating bone loss due to aggressive osteoclastogenesis. PMID:23393600

  3. Biomechanical investigation of different surgical strategies for the treatment of rib fractures using a three-dimensional human respiratory model.

    PubMed

    Shih, Kao-Shang; Truong, Thanh An; Hsu, Ching-Chi; Hou, Sheng-Mou

    2017-11-02

    Rib fracture is a common injury and can result in pain during respiration. Conservative treatment of rib fracture is applied via mechanical ventilation. However, ventilator-associated complications frequently occur. Surgical fixation is another approach to treat rib fractures. Unfortunately, this surgical treatment is still not completely defined. Past studies have evaluated the biomechanics of the rib cage during respiration using a finite element method, but only intact conditions were modelled. Thus, the purpose of this study was to develop a realistic numerical model of the human rib cage and to analyse the biomechanical performance of intact, injured and treated rib cages. Three-dimensional finite element models of the human rib cage were developed. Respiratory movement of the human rib cage was simulated to evaluate the strengths and limitations of different scenarios. The results show that a realistic human respiratory movement can be simulated and the predicted results were closely related to previous study (correlation coefficient>0.92). Fixation of two fractured ribs significantly decreased the fixation index (191%) compared to the injured model. This fixation may provide adequate fixation stability as well as reveal lower bone stress and implant stress compared with the fixation of three or more fractured ribs.

  4. Diagnostic value and clinical laboratory associations of antibodies against recombinant ribosomal P0, P1 and P2 proteins and their native heterocomplex in a Caucasian cohort with systemic lupus erythematosus.

    PubMed

    Barkhudarova, Fidan; Dähnrich, Cornelia; Rosemann, Anke; Schneider, Udo; Stöcker, Winfried; Burmester, Gerd-Rüdiger; Egerer, Karl; Schlumberger, Wolfgang; Hiepe, Falk; Biesen, Robert

    2011-02-10

    In this study, we sought to determine the diagnostic value and clinical laboratory associations of autoantibodies against recombinant ribosomal P0, P1 and P2 proteins and their native heterocomplex in systemic lupus erythematosus (SLE). Autoantibodies against recombinant ribosomal P proteins (aRibPR0, aRibPR1 and aRibPR2) and antibodies against native ribosomal P heterocomplex (aRibPNH) were determined in sera from patients with SLE (n = 163), systemic sclerosis (n = 66), Sjögren's syndrome (n = 54), rheumatoid arthritis (n = 90) and healthy donors (n = 100) using enzyme-linked immunosorbent assay. Test results were correlated to medical records, including the American College of Rheumatology criteria, the Systemic Lupus Erythematosus Disease Activity Index 2000, laboratory data and medications of all SLE patients. Sensitivities of 22.0% for aRibPR0, 14.9% for aRibPR2, 14.3% for aRibPNH and 10.7% for aRibPR1 were obtained at a specificity of 99%. The assay for aRibPR0 detection demonstrated the best performance in receiver-operating characteristics analysis, with aRibPR0 detectable in 10% of anti-Smith antibody and anti-double-stranded DNA-negative sera at a specificity of 100%. ARibPR0 positivity was associated with lymphocytopenia. ARibPR1+ patients had significantly higher γ-glutamyl transpeptidase (GGT) levels than their aRibPR1- counterparts. No specific damage occurred in aRibP+ lupus patients compared with a group of age-, sex- and nephritis-matched aRibP- lupus patients within 3 years. The determination of antibodies against ribosomal P proteins improves the diagnosis of SLE and should therefore be implemented in upcoming criteria for the diagnosis or classification of SLE. High titers of aRibPR0 can be associated with lymphocytopenia, and high titers of aRibPR1 can be associated with elevated GGT levels. So far, there is no evidence for a prognostic value of aRibPs for damage.

  5. Future Opportunities at the Facility for Rare Isotope Beams

    NASA Astrophysics Data System (ADS)

    Sherrill, Bradley M.

    2018-05-01

    This paper overviews the Facility for Rare Isotope Beams, FRIB, its construction status at the time of the conference, and its scientific program. FRIB is based on a high-power, heavy-ion, superconducting linear accelerator that is designed to deliver at least 400kW at 200 MeV/u for all stable-ion beams and produce a large fraction of all possible isotopes of the elements. A three-stage fragment separator will separate rare isotope beams for use in experiments at high energy or stopped and reaccelerated to up to 10MeV/u. The facility is expected to have first beams in 2021. An overview of the planned scientific program, experimental capabilities, and equipment initiatives are presented.

  6. The number of displaced rib fractures is more predictive for complications in chest trauma patients.

    PubMed

    Chien, Chih-Ying; Chen, Yu-Hsien; Han, Shih-Tsung; Blaney, Gerald N; Huang, Ting-Shuo; Chen, Kuan-Fu

    2017-02-28

    Traumatic rib fractures can cause chest complications that need further treatment and hospitalization. We hypothesized that an increase in the number of displaced rib fractures will be accompanied by an increase in chest complications. We retrospectively reviewed the trauma registry between January 2013 and May 2015 in a teaching hospital in northeastern Taiwan. Patients admitted with chest trauma and rib fractures without concomitant severe brain, splenic, pelvic or liver injuries were included. The demographic data, such as gender, age, the index of coexistence disease, alcohol consumption, trauma mechanisms were analyzed as potential predictors of pulmonary complications. Pulmonary complications were defined as pneumothorax, hemothorax, flail chest, pulmonary contusion, and pneumonia. In the 29 months of the study period, a total of 3151 trauma patients were admitted to our hospital. Among them, 174 patients were enrolled for final analysis. The most common trauma mechanism was road traffic accidents (58.6%), mainly motorbike accidents (n = 70, 40.2%). Three or more displaced rib fractures had higher specificity for predicting complications, compared to three or more total rib fractures (95.5% vs 59.1%). Adjusting the severity of chest trauma using TTSS and Ribscore by multivariable logistic regression analysis, we found that three or more rib fractures or any displaced rib fracture was the most significant predictor for developing pulmonary complication (aOR: 5.49 95% CI: 1.82-16.55). Furthermore, there were 18/57 (31.6%) patients with fewer than three ribs fractures developed pulmonary complications. In these 18 patients, only five patients had delayed onset complications and four of them had at least one displaced rib fracture. In this retrospective cohort study, we found that the number of displaced or total rib fractures, bilateral rib fractures, and rib fractures in more than two areas were associated with the more chest complications. Furthermore, three or more rib fracture or any displacement were found to be the most sensitive risk factor for chest complications, independent of other risk factors or severity index. The number of displaced rib fractures could be a strong predictor for developing pulmonary complications. For patients with fewer than three rib fractures without rib displacement and initial lung or other organ injuries, outpatient management could be safe and efficient.

  7. Trial of Injected Liposomal Bupivacaine vs Bupivacaine Infusion After Surgical Stabilization of Rib Fractures

    ClinicalTrials.gov

    2017-10-06

    Drug Effect; Rib Fractures; Rib Trauma; Surgical Procedure, Unspecified; Pain; Catheter (Other); Nerve Pain; Local Infiltration; Anesthesia, Local; Intercostal Rib; Opioid Dependence; Chest Injury Trauma; Pneumonia

  8. Computed Tomography Measurement of Rib Cage Morphometry in Emphysema

    PubMed Central

    Sverzellati, Nicola; Colombi, Davide; Randi, Giorgia; Pavarani, Antonio; Silva, Mario; Walsh, Simon L.; Pistolesi, Massimo; Alfieri, Veronica; Chetta, Alfredo; Vaccarezza, Mauro; Vitale, Marco; Pastorino, Ugo

    2013-01-01

    Background Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers. Methods Rib cage diameters and areas (calculated from the inner surface of the rib cage) in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT). CTs were analyzed with software, which allows quantification of total emphysema (emphysema%). The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models. Results A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1)%, and forced vital capacity (FVC)% fit best with the rib cage measurements (R2 = 64% for the rib cage area variation at the lower anatomical level). Gender had the biggest impact on rib cage diameter and area (105.3 cm2; 95% CI: 111.7 to 98.8 for male lower area). Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%). Lower rib cage areas decreased as FVC% decreased (5.1 cm2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation). Conclusions This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema. PMID:23935872

  9. ribB and ribBA genes from Acidithiobacillus ferrooxidans: expression levels under different growth conditions and phylogenetic analysis.

    PubMed

    Knegt, Fábio H P; Mello, Luciane V; Reis, Fernanda C; Santos, Marcos T; Vicentini, Renato; Ferraz, Lúcio F C; Ottoboni, Laura M M

    2008-01-01

    Acidithiobacillus ferrooxidans is a Gram-negative, chemolithoautotrophic bacterium involved in metal bioleaching. Using the RNA arbitrarily primed polymerase chain reaction (RAP-PCR), we have identified several cDNAs that were differentially expressed when A. ferrooxidans LR was submitted to potassium- and phosphate-limiting conditions. One of these cDNAs showed similarity with ribB. An analysis of the A. ferrooxidans ATCC 23270 genome, made available by The Institute for Genomic Research, showed that the ribB gene was not located in the rib operon, but a ribBA gene was present in this operon instead. The ribBA gene was isolated from A. ferrooxidans LR and expression of both ribB and ribBA was investigated. Transcript levels of both genes were enhanced in cells grown in the absence of K2HPO4, in the presence of zinc and copper sulfate and in different pHs. Transcript levels decreased upon exposure to a temperature higher than the ideal 30 degrees C and at pH 1.2. A comparative genomic analysis using the A. ferrooxidans ATCC 23270 genome revealed similar putative regulatory elements for both genes. Moreover, an RFN element was identified upstream from the ribB gene. Phylogenetic analysis of the distribution of RibB and RibBA in bacteria showed six different combinations. We suggest that the presence of duplicated riboflavin synthesis genes in bacteria must provide their host with some benefit in certain stressful situations.

  10. Comparative Study of Convective Heat Transfer Performance of Steam and Air Flow in Rib Roughened Channels

    NASA Astrophysics Data System (ADS)

    Ma, Chao; Ji, Yongbin; Ge, Bing; Zang, Shusheng; Chen, Hua

    2018-04-01

    A comparative experimental study of heat transfer characteristics of steam and air flow in rectangular channels roughened with parallel ribs was conducted by using an infrared camera. Effects of Reynolds numbers and rib angles on the steam and air convective heat transfer have been obtained and compared with each other for the Reynolds number from about 4,000 to 15,000. For all the ribbed channels the rib pitch to height ratio (p/e) is 10, and the rib height to the channel hydraulic diameter ratio is 0.078, while the rib angles are varied from 90° to 45°. Based on experimental results, it can be found that, even though the heat transfer distributions of steam and air flow in the ribbed channels are similar to each other, the steam flow can obtain higher convective heat transfer enhancement capability, and the heat transfer enhancement of both the steam and air becomes greater with the rib angle deceasing from 90° to 45°. At Reynolds number of about 12,000, the area-averaged Nusselt numbers of the steam flow is about 13.9%, 14.2%, 19.9% and 23.9% higher than those of the air flow for the rib angles of 90°, 75°, 60° and 45° respectively. With the experimental results the correlations for Nusselt number in terms of Reynolds number and rib angle for the steam and air flow in the ribbed channels were developed respectively.

  11. Traumatic Rib Injury: Patterns, Imaging Pitfalls, Complications, and Treatment.

    PubMed

    Talbot, Brett S; Gange, Christopher P; Chaturvedi, Apeksha; Klionsky, Nina; Hobbs, Susan K; Chaturvedi, Abhishek

    2017-01-01

    The ribs are frequently affected by blunt or penetrating injury to the thorax. In the emergency department setting, it is vital for the interpreting radiologist to not only identify the presence of rib injuries but also alert the clinician about organ-specific injury, specific traumatic patterns, and acute rib trauma complications that require emergent attention. Rib injuries can be separated into specific morphologic fracture patterns that include stress, buckle, nondisplaced, displaced, segmental, and pathologic fractures. Specific attention is also required for flail chest and for fractures due to pediatric nonaccidental trauma. Rib fractures are associated with significant morbidity and mortality, both of which increase as the number of fractured ribs increases. Key complications associated with rib fracture include pain, hemothorax, pneumothorax, extrapleural hematoma, pulmonary contusion, pulmonary laceration, acute vascular injury, and abdominal solid-organ injury. Congenital anomalies, including supernumerary or accessory ribs, vestigial anterior ribs, bifid ribs, and synostoses, are common and should not be confused with traumatic pathologic conditions. Nontraumatic mimics of traumatic rib injury, with or without fracture, include metastatic disease, primary osseous neoplasms (osteosarcoma, chondrosarcoma, Ewing sarcoma, Langerhans cell histiocytosis, and osteochondroma), fibrous dysplasia, and Paget disease. Principles of management include supportive and procedural methods of alleviating pain, treating complications, and stabilizing posttraumatic deformity. By recognizing and accurately reporting the imaging findings, the radiologist will add value to the care of patients with thoracic trauma. Online supplemental material is available for this article. © RSNA, 2017.

  12. Rib fixation for severe chest deformity due to multiple rib fractures.

    PubMed

    Igai, Hitoshi; Kamiyoshihara, Mitsuhiro; Nagashima, Toshiteru; Ohtaki, Yoichi

    2012-01-01

    The operative indications for rib fracture repair have been a matter of debate. However, several reports have suggested that flail chest, pain on respiration, and chest deformity/defect are potential conditions for rib fracture repair. We describe our experience of rib fixation in a patient with severe chest deformity due to multiple rib fractures. A 70-year-old woman was admitted with right-sided multiple rib fractures (2nd to 7th) and marked chest wall deformity without flailing caused by an automobile accident. Collapse of the chest wall was observed along the middle anterior axillary line. At 11 days after the injury, surgery was performed to repair the chest deformity, as it was considered to pose a risk of restrictive impairment of pulmonary function or chronic intercostal pain in the future. Operative findings revealed marked displacement of the superior 4 ribs, from the 2nd to the 5th, and collapse of the osseous chest wall towards the thoracic cavity. After exposure of the fracture regions, ribs fixations were performed using rib staplers. The total operation time was 90 minutes, and the collapsed portion of the chest wall along the middle anterior axillary line was reconstructed successfully.

  13. Experimental and numerical analysis of interlocking rib formation at sheet metal blanking

    NASA Astrophysics Data System (ADS)

    Bolka, Špela; Bratuš, Vitoslav; Starman, Bojan; Mole, Nikolaj

    2018-05-01

    Cores for electrical motors are typically produced by blanking of laminations and then stacking them together, with, for instance, interlocking ribs or welding. Strict geometrical tolerances, both on the lamination and on the stack, combined with complex part geometry and harder steel strip material, call for use of predictive methods to optimize the process before actual blanking to reduce the costs and speed up the process. One of the major influences on the final stack geometry is the quality of the interlocking ribs. A rib is formed in one step and joined with the rib of the preceding lamination in the next. The quality of the joint determines the firmness of the stack and also influences its. The geometrical and positional accuracy is thus crucial in rib formation process. In this study, a complex experimental and numerical analysis of interlocking rib formation has been performed. The aim of the analysis is to numerically predict the shape of the rib in order to perform a numerical simulation of the stack formation in the next step of the process. A detailed experimental research has been performed in order to characterize influential parameters on the rib formation and the geometry of the ribs itself, using classical and 3D laser microscopy. The formation of the interlocking rib is then simulated using Abaqus Explicit. The Hilll 48 constitutive material model is based on extensive and novel material characterization process, combining data from in-plane and out-of-plane material tests to perform a 3D analysis of both, rib formation and rib joining. The study shows good correlation between the experimental and numerical results.

  14. Association of Ipsilateral Rib Fractures With Displacement of Midshaft Clavicle Fractures.

    PubMed

    Stahl, Daniel; Ellington, Matthew; Brennan, Kindyle; Brennan, Michael

    2017-04-01

    To determine whether the presence of ipsilateral rib fractures affects the rate of a clavicle fracture being unstable (>100% displacement). A retrospective review from 2002-2013 performed at a single level 1 trauma center evaluated 243 midshaft clavicle fractures. Single Level 1 trauma center. These fractures were subdivided into those with ipsilateral rib fractures (CIR; n = 149) and those without ipsilateral rib fractures (CnIR; n = 94). The amount of displacement was measured on the initial injury radiograph and subsequent follow-up radiographs. Fractures were classified into either <100% displacement or >100% displacement, based on anteroposterior radiographs. Ipsilateral rib fractures were recorded based on which number rib was fractured and the total number of fractured ribs. One hundred sixteen (78%) of the CIR group and 51 (54%) of the CnIR group were found to have >100% displacement at follow-up (P = 0.0047). Seventy-two percent of the CIR group demonstrated progression from <100% to >100% displacement of the fracture compared with only 54% of the CnIR group (P < 0.05). The odds ratio for progression of the clavicle fracture to >100% was 4.08 (P = 0.000194) when ribs 1-4 were fractured and not significant for rib fractures 5-8 or 9-12. The presence of concomitant ipsilateral rib fractures significantly increases the rate of midshaft clavicle fractures being >100% displaced. In addition, a fracture involving the upper one-third of the ribs significantly increases the rate of the clavicle fracture being >100% displaced on early follow-up. Clavicle fractures with associated ipsilateral rib fractures tend to demonstrate an increased amount of displacement on follow-up radiographs compared with those without ipsilateral rib fractures. Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

  15. Bone suppression technique for chest radiographs

    NASA Astrophysics Data System (ADS)

    Huo, Zhimin; Xu, Fan; Zhang, Jane; Zhao, Hui; Hobbs, Susan K.; Wandtke, John C.; Sykes, Anne-Marie; Paul, Narinder; Foos, David

    2014-03-01

    High-contrast bone structures are a major noise contributor in chest radiographic images. A signal of interest in a chest radiograph could be either partially or completely obscured or "overshadowed" by the highly contrasted bone structures in its surrounding. Thus, removing the bone structures, especially the posterior rib and clavicle structures, is highly desirable to increase the visibility of soft tissue density. We developed an innovative technology that offers a solution to suppress bone structures, including posterior ribs and clavicles, on conventional and portable chest X-ray images. The bone-suppression image processing technology includes five major steps: 1) lung segmentation, 2) rib and clavicle structure detection, 3) rib and clavicle edge detection, 4) rib and clavicle profile estimation, and 5) suppression based on the estimated profiles. The bone-suppression software outputs an image with both the rib and clavicle structures suppressed. The rib suppression performance was evaluated on 491 images. On average, 83.06% (±6.59%) of the rib structures on a standard chest image were suppressed based on the comparison of computer-identified rib areas against hand-drawn rib areas, which is equivalent to about an average of one rib that is still visible on a rib-suppressed image based on a visual assessment. Reader studies were performed to evaluate reader performance in detecting lung nodules and pneumothoraces with and without a bone-suppression companion view. Results from reader studies indicated that the bone-suppression technology significantly improved radiologists' performance in the detection of CT-confirmed possible nodules and pneumothoraces on chest radiographs. The results also showed that radiologists were more confident in making diagnoses regarding the presence or absence of an abnormality after rib-suppressed companion views were presented

  16. Quantitative analysis of rib movement based on dynamic chest bone images: preliminary results

    NASA Astrophysics Data System (ADS)

    Tanaka, R.; Sanada, S.; Oda, M.; Mitsutaka, M.; Suzuki, K.; Sakuta, K.; Kawashima, H.

    2014-03-01

    Rib movement during respiration is one of the diagnostic criteria in pulmonary impairments. In general, the rib movement is assessed in fluoroscopy. However, the shadows of lung vessels and bronchi overlapping ribs prevent accurate quantitative analysis of rib movement. Recently, an image-processing technique for separating bones from soft tissue in static chest radiographs, called "bone suppression technique", has been developed. Our purpose in this study was to evaluate the usefulness of dynamic bone images created by the bone suppression technique in quantitative analysis of rib movement. Dynamic chest radiographs of 10 patients were obtained using a dynamic flat-panel detector (FPD). Bone suppression technique based on a massive-training artificial neural network (MTANN) was applied to the dynamic chest images to create bone images. Velocity vectors were measured in local areas on the dynamic bone images, which formed a map. The velocity maps obtained with bone and original images for scoliosis and normal cases were compared to assess the advantages of bone images. With dynamic bone images, we were able to quantify and distinguish movements of ribs from those of other lung structures accurately. Limited rib movements of scoliosis patients appeared as reduced rib velocity vectors. Vector maps in all normal cases exhibited left-right symmetric distributions, whereas those in abnormal cases showed nonuniform distributions. In conclusion, dynamic bone images were useful for accurate quantitative analysis of rib movements: Limited rib movements were indicated as a reduction of rib movement and left-right asymmetric distribution on vector maps. Thus, dynamic bone images can be a new diagnostic tool for quantitative analysis of rib movements without additional radiation dose.

  17. Selected List of Low Energy Beam Transport Facilities for Light-Ion, High-Intensity Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prost, L. R.

    This paper presents a list of Low Energy Beam Transport (LEBT) facilities for light-ion, high-intensity accelerators. It was put together to facilitate comparisons with the PXIE LEBT design choices. A short discussion regarding the importance of the beam perveance in the choice of the transport scheme follows.

  18. Effects of Pin Detached Space on Heat Transfer in a Rib Roughened Channel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siw, Sin Chien; Chyu, Minking K.; Alvin, Mary Anne

    2012-11-08

    An experimental study is performed to investigate the heat transfer characteristics and frictional losses in a rib roughened channel combined with detached pin-fins. The overall channel geometry (W=76.2 mm, E=25.4 mm) simulates an internal cooling passage of wide aspect ratio (3:1) in a gas turbine airfoil. With a given pin diameter, D=6.35 mm=[1/4]E, three different pin-fin height-to-diameter ratios, H/D=4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin-tip and one of the endwalls, i.e., C/O=0, 1, 2, respectively. The rib height-to-channel height ratio is 0.0625.more » Two newly proposed cross ribs, namely the broken rib and full rib are evaluated in this effort. The broken ribs are positioned in between two consecutive rows of pin-fins, while the full ribs are fully extended adjacent to the pin-fins. The Reynolds number, based on the hydraulic diameter of the unobstructed cross section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all pin elements. The presence of ribs enhances local heat transfer coefficient on the endwall substantially by approximately 20% to 50% as compared to the neighboring endwall. In addition, affected by the rib geometry, which is a relatively low profile as compared to the overall height of the channel, the pressure loss seems to be insensitive to the presence of the ribs. However, from the overall heat transfer enhancement standpoint, the baseline cases (without ribs) outperform cases with broken ribs or full ribs.« less

  19. Radiation-induced rib fracture after stereotactic body radiotherapy with a total dose of 54-56 Gy given in 9-7 fractions for patients with peripheral lung tumor: impact of maximum dose and fraction size.

    PubMed

    Aoki, Masahiko; Sato, Mariko; Hirose, Katsumi; Akimoto, Hiroyoshi; Kawaguchi, Hideo; Hatayama, Yoshiomi; Ono, Shuichi; Takai, Yoshihiro

    2015-04-22

    Radiation-induced rib fracture after stereotactic body radiotherapy (SBRT) for lung cancer has been recently reported. However, incidence of radiation-induced rib fracture after SBRT using moderate fraction sizes with a long-term follow-up time are not clarified. We examined incidence and risk factors of radiation-induced rib fracture after SBRT using moderate fraction sizes for the patients with peripherally located lung tumor. During 2003-2008, 41 patients with 42 lung tumors were treated with SBRT to 54-56 Gy in 9-7 fractions. The endpoint in the study was radiation-induced rib fracture detected by CT scan after the treatment. All ribs where the irradiated doses were more than 80% of prescribed dose were selected and contoured to build the dose-volume histograms (DVHs). Comparisons of the several factors obtained from the DVHs and the probabilities of rib fracture calculated by Kaplan-Meier method were performed in the study. Median follow-up time was 68 months. Among 75 contoured ribs, 23 rib fractures were observed in 34% of the patients during 16-48 months after SBRT, however, no patients complained of chest wall pain. The 4-year probabilities of rib fracture for maximum dose of ribs (Dmax) more than and less than 54 Gy were 47.7% and 12.9% (p = 0.0184), and for fraction size of 6, 7 and 8 Gy were 19.5%, 31.2% and 55.7% (p = 0.0458), respectively. Other factors, such as D2cc, mean dose of ribs, V10-55, age, sex, and planning target volume were not significantly different. The doses and fractionations used in this study resulted in no clinically significant rib fractures for this population, but that higher Dmax and dose per fraction treatments resulted in an increase in asymptomatic grade 1 rib fractures.

  20. Jefferson Lab Science: Present and Future

    DOE PAGES

    McKeown, Robert D.

    2015-02-12

    The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for experimental nuclear physics. Furthermore, this facility is presently being upgraded, which will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility.

  1. Rib kinematics during lung ventilation in the American alligator (Alligator mississippiensis): an XROMM analysis

    PubMed Central

    Moritz, Sabine; Codd, Jonathan; Sellers, William I.

    2017-01-01

    ABSTRACT The current hypothesis regarding the mechanics of breathing in crocodylians is that the double-headed ribs, with both a capitulum and tuberculum, rotate about a constrained axis passing through the two articulations; moreover, this axis shifts in the caudal thoracic ribs, as the vertebral parapophysis moves from the centrum to the transverse process. Additionally, the ventral ribcage in crocodylians is thought to possess additional degrees of freedom through mobile intermediate ribs. In this study, X-ray reconstruction of moving morphology (XROMM) was used to quantify rib rotation during breathing in American alligators. Whilst costovertebral joint anatomy predicted overall patterns of motion across the ribcage (decreased bucket handle motion and increased calliper motion), there were significant deviations: anatomical axes overestimated pump handle motion and, generally, ribs in vivo rotate about all three body axes more equally than predicted. The intermediate ribs are mobile, with a high degree of rotation measured about the dorsal intracostal joints, especially in the more caudal ribs. Motion of the sternal ribs became increasingly complex caudally, owing to a combination of the movements of the vertebral and intermediate segments. As the crocodylian ribcage is sometimes used as a model for the ancestral archosaur, these results have important implications for how rib motion is reconstructed in fossil taxa, and illustrate the difficulties in reconstructing rib movement based on osteology alone. PMID:28855323

  2. Ribbed moraine formation

    NASA Astrophysics Data System (ADS)

    Hättestrand, Clas; Kleman, Johan

    Ribbed (Rogen) moraines are conspicuous landforms found in interior parts of formerly glaciated areas. Two major theories for ribbed moraine formation have been suggested in recent years: (i) the shear and stack theory, which explains ribbed moraine formation by shearing and stacking of till slabs or englacially entrained material during compressive flow, followed by basal melt-out of transverse moraine ridges, and (ii) the fracturing theory, according to which ribbed moraines form by fracturing of frozen pre-existing till sheets, at the transition from cold- to warm-based conditions under deglaciating ice sheets. In this paper, we present new data on the distribution of ribbed moraines and their close association with areas of frozen-bed conditions under ice sheets. In addition, we show examples of ribbed moraine ridges that fit together like a jig-saw puzzle. These observations indicate that fracturing and extension of a pre-existing till sheet may be a predominant process in ribbed moraine formation. In summary, we conclude that all described characteristics of ribbed moraines are compatible with the fracturing theory, while the shear and stack theory is hampered by an inability to explain many conspicuous features in the distribution pattern and detailed morphology of ribbed moraines. One implication of the fracturing theory is that the distribution of ribbed moraines can be used to reconstruct the extent of areas that underwent a change from frozen-bed to thawed-bed conditions under former ice sheets.

  3. The Design of Airplane Wing Ribs

    NASA Technical Reports Server (NTRS)

    Newlin, J A; Trayer, George W

    1931-01-01

    The purpose of this investigation was to obtain information for use in the design of truss and plywood forms, particularly with reference to wing ribs. Tests were made on many designs of wing ribs, comparing different types in various sizes. Many tests were also made on parallel-chord specimens of truss and plywood forms in place of the actual ribs and on parts of wing ribs, such as truss diagonals and sections of cap strips. It was found that for ribs of any size or proportions, when they were designed to obtain a well-balanced construction and were carefully manufactured, distinct types are of various efficiencies; the efficiency is based on the strength per unit of weight. In all types of ribs the heavier are the stronger per unit of weight. Reductions in the weight of wing ribs are accompanied even in efficient designs by a much greater proportional reduction in strength.

  4. INTERNATIONAL CONFERENCE ON SEMICONDUCTOR INJECTION LASERS SELCO-87: Low-threshold ridge-waveguide 1.3-μm laser

    NASA Astrophysics Data System (ADS)

    Kortàn, J.; Nohavica, D.; Sarma, J.

    1988-11-01

    A description is given of the fabrication and of the main properties of 1.3-μm GaInAsP lasers with a ridge (rib) waveguide structure used for lateral confinement of transverse modes and of the current. Such lasers were made by the method of ion-beam etching and self-alignment photolithography. Narrow ridges (3-5 μm) formed in this way carried Ti-Au Schottky contacts. These lasers were simple to fabricate and their threshold currents were comparable with those in much more complex lasers with buried waveguide structures.

  5. University of Wisconsin Ion Beam Laboratory: A facility for irradiated materials and ion beam analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, K. G.; Wetteland, C. J.; Cao, G.

    2013-04-19

    The University of Wisconsin Ion Beam Laboratory (UW-IBL) has recently undergone significant infrastructure upgrades to facilitate graduate level research in irradiated materials phenomena and ion beam analysis. A National Electrostatics Corp. (NEC) Torodial Volume Ion Source (TORVIS), the keystone upgrade for the facility, can produce currents of hydrogen ions and helium ions up to {approx}200 {mu}A and {approx}5 {mu}A, respectively. Recent upgrades also include RBS analysis packages, end station developments for irradiation of relevant material systems, and the development of an in-house touch screen based graphical user interface for ion beam monitoring. Key research facilitated by these upgrades includes irradiationmore » of nuclear fuels, studies of interfacial phenomena under irradiation, and clustering dynamics of irradiated oxide dispersion strengthened steels. The UW-IBL has also partnered with the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) to provide access to the irradiation facilities housed at the UW-IBL as well as access to post irradiation facilities housed at the UW Characterization Laboratory for Irradiated Materials (CLIM) and other ATR-NSUF partner facilities. Partnering allows for rapid turnaround from proposed research to finalized results through the ATR-NSUF rapid turnaround proposal system. An overview of the UW-IBL including CLIM and relevant research is summarized.« less

  6. Rib fracture repair: indications, technical issues, and future directions.

    PubMed

    Nirula, Raminder; Diaz, Jose J; Trunkey, Donald D; Mayberry, John C

    2009-01-01

    Rib fracture repair has been performed at selected centers around the world for more than 50 years; however, the operative indications have not been established and are considered controversial. The outcome of a strictly nonoperative approach may not be optimal. Potential indications for rib fracture repair include flail chest, painful, movable rib fractures refractory to conventional pain management, chest wall deformity/defect, rib fracture nonunion, and during thoracotomy for other traumatic indication. Rib fracture repair is technically challenging secondary to the human rib's relatively thin cortex and its tendency to fracture obliquely. Nonetheless, several effective repair systems have been developed. Future directions for progress on this important surgical problem include the development of minimally invasive techniques and the conduct of multicenter, randomized trials.

  7. Rib fractures induced by coughing: an unusual cause of acute chest pain.

    PubMed

    De Maeseneer, M; De Mey, J; Debaere, C; Meysman, M; Osteaux, M

    2000-03-01

    We report three patients with stress fractures of the ribs induced by coughing. Standard radiographs of the chest and ribs did not reveal evidence of rib fractures in any of the patients. Bone scintigraphy, performed 1 to 2 weeks after initial onset of symptoms, showed a focal area of increased uptake along the chest wall in all cases. Thin section angulated helical CT directly visualized the subtle rib fractures. Initial diagnosis of a cough-induced fracture of the rib may be difficult because of the associated underlying disorder, and unnecessary examinations are commonly performed. Identification of a cough-induced fracture of the rib using helical CT may be clinically important to avoid unnecessary concern and additional examinations.

  8. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    PubMed

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in most patients presenting with suspected rib fractures. Moreover USG requires significantly less time than radiography. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  9. Rib fracture as a predictor of future fractures in young and older postmenopausal women: National Osteoporosis Risk Assessment (NORA)

    PubMed Central

    Sajjan, S. G.; Barrett-Connor, E.; McHorney, C. A.; Miller, P. D.; Sen, S. S.; Siris, E.

    2013-01-01

    Summary A rib fracture history after age 45 was associated with a 5.4-fold increase in new rib fracture risk and a 2.4-fold increase in risk of any new clinical fracture in 155,031 postmenopausal women. A rib fracture history suggests osteoporosis and should be considered when evaluating patients for interventions to prevent fractures. Introduction Until recently, little attention was paid to rib fracture as an osteoporosis marker. Emerging evidence suggests rib fracture may be an osteoporotic fracture in men and women. We report the 5-year independent association between baseline rib fracture histories and self-reported future fractures by age (decade) in the NORA cohort (155,031 postmenopausal women, 50–99 years). Methods Participants reported fracture history and responded to follow-up surveys at years 1, 3, or 6. Women with a baseline rib fracture history without other fractures were compared with women with no fracture. Results At baseline, 4,758 (3.07%) women reported a rib fracture history without other fractures; 6,300 women reported 6,830 new clinical fractures, including wrist (2,271), rib (1,891), spine (1,136), hip (941), and forearm (591). Adjusted relative risk (ARR) values (95% confidence interval [CI]) for future fractures in women with rib fracture history versus women with no fracture history were 5.4 (4.8–6.1) at the rib, 2.1 (1.7–2.6) at the spine, and 1.4 (1.1–1.7) at the wrist, and not significant for forearm or hip fractures. Future fracture risk was at least doubled in women with a rib fracture history in all ages: ARR (95% CI) 3.4 (2.8–4.0) for ages 50–59, 2.5 (2.1–3.0) for ages 60–69, 2.0 (1.7–2.3) for ages 70–79, and 2.0 (1.6–2.6) for ages >80. Conclusions Rib fracture, the second most common clinical fracture in women (after wrist fracture), predicted future fractures of the rib, wrist, and spine at all ages. Women presenting with rib fractures should be evaluated for appropriate management to prevent future fractures. PMID:21904951

  10. SPIRAL2 at GANIL: Status and Perspectives

    NASA Astrophysics Data System (ADS)

    Gales, S.

    2008-05-01

    To pursue the investigation of a new territory of nuclei with extreme N/Z called ``terra incognita'' several projects, all aiming at the increase by several orders of magnitude of the RIB intensities are now under discussions worldwide. In Europe, two major new projects have been approved recently FAIRatGSI using the so-called ``in-flight'' method and SPIRAL2atGANIL, based on the ISOL method. Both projects were selected in the European Strategic Roadmap For research Infrastructures (ESFRI). The main goal of SPIRAL2 is clearly to extend our knowledge of the limit of existence and the structure of nuclei deeply in the medium and heavy mass region (A = 60 to 140) which is to day an almost unexplored continent. SPIRAL 2 is based on a high power, CW, superconducting driver LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more 1013 fissions/s. The expected radioactive beams intensities for exotic species in the mass range from A = 60 to A = 140, of the order of 106 to 1010 pps will surpass by two order of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100 μA to 1 mA), heavier ions up to Ar at 14 MeV/n producing also proton rich exotic nuclei. In applied areas SPIRAL2 is considered as a powerful variable energy neutron source, a must to study the impact of nuclear fission and fusion on materials. The intensities of these unstable species are excellent opportunities for new tracers and diagnostics either for solid state, material or for radiobiological science and medicine. The ``Go'' decision has been taken in May 2005. The investments and personnel costs amount to 190 M€, for the construction period 2006-2012. Construction of the SPIRAL2 facility is shared by ten French laboratories and a network of international partners. Under the 7FP program of European Union called ``Preparatory phase for the construction of new facilities ``, the SPIRAL2 project has been granted a budget of about 4M€ to build up an international consortium around this new venture. The status of the construction of SPIRAL2 accelerator and technical R&D programs for physics instrumentation (detectors, spectrometers) in collaboration with EU and International partners will be presented.

  11. Testing of stiffening ribs formed by incremental forming in thin-walled aircraft structures made of 2024-T3 ALCLAD aluminium alloy

    NASA Astrophysics Data System (ADS)

    Kubit, Andrzej; Wydrzynski, Dawid; Bucior, Magdalena; Krasowski, Bogdan

    2018-05-01

    This paper presents the results of experimental tests on the fabrication of longitudinal stiffening ribs in 2024-T3 ALCLAD aluminum alloy sheet, which is widely used in the aircraft structures. The problem presented in this paper concerns the concept of rib-stiffening of the structure of aircraft skin. The ribs are intended to stiffen integral thin-walled structure. Different shapes and different parameters of the forming process were studied. The rib-stiffened samples of various depths of the ribs were tested experimentally in the buckling test.

  12. Rib fractures: comparison of associated injuries between pediatric and adult population.

    PubMed

    Kessel, Boris; Dagan, Jasmin; Swaid, Forat; Ashkenazi, Itamar; Olsha, Oded; Peleg, Kobi; Givon, Adi; Alfici, Ricardo

    2014-11-01

    Rib fractures are considered a marker of exposure to significant traumatic energy. In children, because of high elasticity of the chest wall, higher energy levels are necessary for ribs to fracture. The purpose of this study was to analyze patterns of associated injuries in children as compared with adults, all of whom presented with rib fractures. A retrospective cohort study involving blunt trauma patients with rib fractures registered in the National Trauma Registry was conducted. Of 6,995 trauma victims who were found to suffer from rib fractures, 328 were children and 6,627 were adults. Isolated rib fractures without associated injuries occurred in 19 children (5.8%) and 731 adults (11%). More adults had 4 or more fractured ribs compared with children (P < .001). Children suffered from higher rates of associated brain injuries (P = .003), hemothorax/pneumothorax (P = .006), spleen, and liver injury (P < .001). Mortality rate was 5% in both groups. The incidence of associated head, thoracic, and abdominal solid organ injuries in children was significantly higher than in adults suffering from rib fractures. In spite of a higher Injury Severity Score and incidence of associated injuries, mortality rate was similar. Mortality of rib fracture patients was mostly affected by the presence of extrathoracic injuries. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Measurement of heat transfer and pressure drop in rectangular channels with turbulence promoters

    NASA Technical Reports Server (NTRS)

    Han, J. C.; Park, J. S.; Ibrahim, M. Y.

    1986-01-01

    Periodic rib turbulators were used in advanced turbine cooling designs to enhance the internal heat transfer. The objective of the present project was to investigate the combined effects of the rib angle of attack and the channel aspect ratio on the local heat transfer and pressure drop in rectangular channels with two opposite ribbed walls for Reynolds number varied from 10,000 to 60,000. The channel aspect ratio (W/H) was varied from 1 to 2 to 4. The rib angle of attack (alpha) was varied from 90 to 60 to 45 to 30 degree. The highly detailed heat transfer coefficient distribution on both the smooth side and the ribbed side walls from the channel sharp entrance to the downstream region were measured. The results showed that, in the square channel, the heat transfer for the slant ribs (alpha = 30 -45 deg) was about 30% higher that of the transverse ribs (alpha = 90 deg) for a constant pumping power. However, in the rectangular channels (W/H = 2 and 4, ribs on W side), the heat transfer at alpha = 30 -45 deg was only about 5% higher than 90 deg. The average heat transfer and friction correlations were developed to account for rib spacing, rib angle, and channel aspect ratio over the range of roughness Reynolds number.

  14. Accelerator Physics Working Group Summary

    NASA Astrophysics Data System (ADS)

    Li, D.; Uesugi, T.; Wildnerc, E.

    2010-03-01

    The Accelerator Physics Working Group addressed the worldwide R&D activities performed in support of future neutrino facilities. These studies cover R&D activities for Super Beam, Beta Beam and muon-based Neutrino Factory facilities. Beta Beam activities reported the important progress made, together with the research activity planned for the coming years. Discussion sessions were also organized jointly with other working groups in order to define common ground for the optimization of a future neutrino facility. Lessons learned from already operating neutrino facilities provide key information for the design of any future neutrino facility, and were also discussed in this meeting. Radiation damage, remote handling for equipment maintenance and exchange, and primary proton beam stability and monitoring were among the important subjects presented and discussed. Status reports for each of the facility subsystems were presented: proton drivers, targets, capture systems, and muon cooling and acceleration systems. The preferred scenario for each type of possible future facility was presented, together with the challenges and remaining issues. The baseline specification for the muon-based Neutrino Factory was reviewed and updated where required. This report will emphasize new results and ideas and discuss possible changes in the baseline scenarios of the facilities. A list of possible future steps is proposed that should be followed up at NuFact10.

  15. Reduction of rib fractures with a bioresorbable plating system: preliminary observations.

    PubMed

    Vu, Kim-Chi; Skourtis, Mia E; Gong, Xi; Zhou, Minhao; Ozaki, Wayne; Winn, Shelley R

    2008-05-01

    Operative fixation of rib fractures can reduce morbidity and mortality. Currently, resorbable fixation devices are used in a variety of surgical procedures. A standard osteotomy was prepared in 30 New Zealand white rabbits at the 12th rib. Eighteen had surgical repair with bioresorbable plates and 12 underwent nonoperative management. Half the animals in each group were killed at 3-week postfracture and the remaining animals were killed at 6-week postfracture. Ribs were radiographed and processed histologically to assess fracture healing. Rib reduction was defined as the alignment of the rib ends in a structural condition similar to the prefractured state and quantitative radiomorphometry measured the radiopaque callus surrounding the rib injury sites. Statistical analysis was performed using Fisher's exact test and an unpaired Student's t test and significance was established at p < 0.05. At both the 3- and 6-week intervals, seven of the nine rib fractures remained reduced in the operative group, whereas zero of six and three of six of the rib fractures remained reduced, respectively, in the nonoperative group. A statistically significant increase in radiopaque callus surrounding the rib injury sites was observed at 3 and 6 weeks in the fixed groups. Fixation of rib fractures with a bioresorbable miniplate system was superior to nonoperative treatment at the 3-week interval, with a statistically significant increase in radiopaque callus formation at both 3 and 6 weeks. Additional studies will evaluate the biomechanical outcomes and degradation tissue response after extended in vivo intervals.

  16. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT.

    PubMed

    Cho, S H; Sung, Y M; Kim, M S

    2012-10-01

    The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.

  17. Hemangioma of the rib showing a relatively high 18F-FDG uptake: a case report with a literature review

    PubMed Central

    Emori, Makoto; Terashima, Yoshinori; Hasegawa, Tadashi; Shimizu, Junya; Nagoya, Satoshi; Yamashita, Toshihiko

    2017-01-01

    Hemangioma of the rib is a rare benign tumor that is often difficult to distinguish from malignant bone tumors. Rib hemangioma often shows bony disruption with a slight cortical disruption, extraosseous lesion, and expanded bone on computed tomography (CT). We report the case of a 68-year-old man with atypical rib hemangioma with a slight cortical disruption and no expanded bone. The tumor showed relatively high 18FDG-uptake on positron emission tomography (PET)/CT. Rib hemangioma often shows higher 18FDG-uptake. PET/CT may not provide useful information for distinguishing rib hemangioma from a malignant tumor. Close observation without surgical resection may be feasible if the tumor is diagnosed as a rib hemangioma by biopsy. PMID:28959457

  18. RFQ beam cooler and buncher for collinear laser spectroscopy of rare isotopes

    NASA Astrophysics Data System (ADS)

    Barquest, B. R.; Bollen, G.; Mantica, P. F.; Minamisono, K.; Ringle, R.; Schwarz, S.; Sumithrarachchi, C. S.

    2017-09-01

    A radiofrequency quadrupole (RFQ) ion beam cooler and buncher has been developed to deliver bunched beams with low transverse emittance, energy spread, and time spread to the BECOLA collinear laser spectroscopy system at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. The beam cooler and buncher contains new features which enhance performance, especially for high count rate beams, as well as simplifying construction, maintenance, and operation. The transverse emittance, energy spread, and time spread of the bunched beam, as well as buncher efficiency are reported, showcasing the capabilities of the BECOLA facility to perform collinear laser spectroscopy measurements with bunched rare isotope beams at NSCL and at the future Facility for Rare Isotope Beams (FRIB).

  19. Structural characterization of ribT from Bacillus subtilis reveals it as a GCN5-related N-acetyltransferase.

    PubMed

    Srivastava, Ritika; Kaur, Amanpreet; Sharma, Charu; Karthikeyan, Subramanian

    2018-04-01

    In bacteria, biosynthesis of riboflavin occurs through a series of enzymatic steps starting with one molecule of GTP and two molecules of ribulose-5-phosphate. In Bacillus subtilis (B. subtilis) the genes (ribD/G, ribE, ribA, ribH and ribT) which are involved in riboflavin biosynthesis are organized in an operon referred as rib operon. All the genes of rib operon are characterized functionally except for ribT. The ribT gene with unknown function is found at the distal terminal of rib operon and annotated as a putative N-acetyltransferase. Here, we report the crystal structure of ribT from B. subtilis (bribT) complexed with coenzyme A (CoA) at 2.1 Å resolution determined by single wavelength anomalous dispersion method. Our structural study reveals that bribT is a member of GCN5-related N-acetyltransferase (GNAT) superfamily and contains all the four conserved structural motifs that have been in other members of GNAT superfamily. The members of GNAT family transfers the acetyl group from acetyl coenzyme A (AcCoA) to a variety of substrates. Moreover, the structural analysis reveals that the residues Glu-67 and Ser-107 are suitably positioned to act as a catalytic base and catalytic acid respectively suggesting that the catalysis by bribT may follow a direct transfer mechanism. Surprisingly, the mutation of a non-conserved amino acid residue Cys-112 to alanine or serine affected the binding of AcCoA to bribT, indicating a possible role of Cys-112 in the catalysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Rib Cartilage Assessment Relative to the Healthy Ear in Young Children with Microtia Guiding Operative Timing.

    PubMed

    Kang, Shen-Song; Guo, Ying; Zhang, Dong-Yi; Jiang, Du-Yin

    2015-08-20

    The optimal age at which to initiate for auricular reconstruction is controversial. Rib cartilage growth is closely related to age and determines the feasibility and outcomes of auricular reconstruction. We developed a method to guide the timing of auricular reconstruction in children with microtia ranging in age from 5 to 10 years. Rib cartilage and the healthy ear were assessed using low-dose multi-slice computed tomography. The lengths of the eighth rib cartilage and the helix of the healthy ear (from the helical crus to the joint of the helix and the earlobe) were measured. Surgery was performed when the two lengths were approximately equal. The preoperative eighth rib measurements significantly correlated with the intraoperative measurements (P < 0.05). From 5 to 10 years of age, eighth rib growth was not linear. In 76 (62.8%) of 121 patients, the eighth rib length was approximately equal to the helix length in the healthy ear; satisfactory outcomes were achieved in these patients. In 18 (14.9%) patients, the eighth rib was slightly shorter than the helix, helix fabrication was accomplished by adjusting the length of the helical crus of stent, and satisfactory outcomes were also achieved. Acceptable outcomes were achieved in 17 (14.0%) patients in whom helix fabrication was accomplished by cartilage splicing. In 9 (7.4%) patients with insufficient rib cartilage length, the operation was delayed. In one (0.8%) patient with insufficient rib cartilage length, which left no cartilage for helix splicing, the result was unsatisfactory. Eighth rib cartilage growth is variable. Rib cartilage assessment relative to the healthy ear can guide auricular reconstruction and personalize treatment in young patients with microtia.

  1. Factors Associated With Chest Wall Toxicity After Accelerated Partial Breast Irradiation Using High-Dose-Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Sheree, E-mail: shereedst32@hotmail.com; Vicini, Frank; Vanapalli, Jyotsna R.

    2012-07-01

    Purpose: The purpose of this analysis was to evaluate dose-volume relationships associated with a higher probability for developing chest wall toxicity (pain) after accelerated partial breast irradiation (APBI) by using both single-lumen and multilumen brachytherapy. Methods and Materials: Rib dose data were available for 89 patients treated with APBI and were correlated with the development of chest wall/rib pain at any point after treatment. Ribs were contoured on computed tomography planning scans, and rib dose-volume histograms (DVH) along with histograms for other structures were constructed. Rib DVH data for all patients were sampled at all volumes {>=}0.008 cubic centimeter (cc)more » (for maximum dose related to pain) and at volumes of 0.5, 1, 2, and 3 cc for analysis. Rib pain was evaluated at each follow-up visit. Patient responses were marked as yes or no. No attempt was made to grade responses. Eighty-nine responses were available for this analysis. Results: Nineteen patients (21.3%) complained of transient chest wall/rib pain at any point in follow-up. Analysis showed a direct correlation between total dose received and volume of rib irradiated with the probability of developing rib/chest wall pain at any point after follow-up. The median maximum dose at volumes {>=}0.008 cc of rib in patients who experienced chest wall pain was 132% of the prescribed dose versus 95% of the prescribed dose in those patients who did not experience pain (p = 0.0035). Conclusions: Although the incidence of chest wall/rib pain is quite low with APBI brachytherapy, attempts should be made to keep the volume of rib irradiated at a minimum and the maximum dose received by the chest wall as low as reasonably achievable.« less

  2. The etiology of pectus carinatum involves overgrowth of costal cartilage and undergrowth of ribs.

    PubMed

    Park, Chul Hwan; Kim, Tae Hoon; Haam, Seok Jin; Jeon, Inhwan; Lee, Sungsoo

    2014-08-01

    We compared the length of costal cartilage and rib between patients with symmetric pectus carinatum and controls without anterior chest wall protrusion, using a 3-dimensional (3D) computed tomography (CT) to evaluate whether the overgrowth of costal cartilage exists in patients with pectus carinatum. Twenty-six patients with symmetric pectus carinatum and matched twenty-six controls without chest wall protrusion were enrolled. We measured the full lengths of the 4th-6th ribs and costal cartilages using 3-D volume rendering CT images and the curved multiplanar reformatted (MPR) techniques. The lengths of ribs and costal cartilages, the summation of rib and costal cartilage lengths, and the costal index [length of cartilage/length of rib * 100 (%)] were compared between the patients group and the control group at 4th-6th levels. The lengths of costal cartilage in patient group were significantly longer than those of control group at 4th, 5th and 6th rib level. The lengths of ribs in patient group were significantly shorter than those of control group at 4th, 5th and 6th rib level. The summations of rib and costal cartilage lengths were not longer in patients group than in control group. The costal indices were significantly larger in patients group than in control groups at 4th, 5th and 6th rib level. In patients with symmetric pectus carinatum, the lengths of costal cartilage were longer but the lengths of rib were shorter than those of controls. These findings may supports that the overgrowth of costal cartilage was not the only factor responsible for pectus carinatum. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Development and Commissioning of an External Beam Facility in the Union College Ion Beam Analysis Laboratory

    NASA Astrophysics Data System (ADS)

    Yoskowitz, Joshua; Clark, Morgan; Labrake, Scott; Vineyard, Michael

    2015-10-01

    We have developed an external beam facility for the 1.1-MV tandem Pelletron accelerator in the Union College Ion Beam Analysis Laboratory. The beam is extracted from an aluminum pipe through a 1 / 4 ' ' diameter window with a 7.5- μm thick Kapton foil. This external beam facility allows us to perform ion beam analysis on samples that cannot be put under vacuum, including wet samples and samples too large to fit into the scattering chamber. We have commissioned the new facility by performing proton induced X-ray emission (PIXE) analysis of several samples of environmental interest. These include samples of artificial turf, running tracks, and a human tooth with an amalgam filling. A 1.7-MeV external proton beam was incident on the samples positioned 2 cm from the window. The resulting X-rays were measured using a silicon drift detector and were analyzed using GUPIX software to determine the concentrations of elements in the samples. The results on the human tooth indicate that while significant concentrations of Hg, Ag, and Sn are present in the amalgam filling, only trace amounts of Hg appear to have leached into the tooth. The artificial turf and running tracks show rather large concentrations of a broad range of elements and trace amounts of Pb in the turf infill.

  4. Beam line shielding calculations for an Electron Accelerator Mo-99 production facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mocko, Michal

    2016-05-03

    The purpose of this study is to evaluate the photon and neutron fields in and around the latest beam line design for the Mo-99 production facility. The radiation dose to the beam line components (quadrupoles, dipoles, beam stops and the linear accelerator) are calculated in the present report. The beam line design assumes placement of two cameras: infra red (IR) and optical transition radiation (OTR) for continuous monitoring of the beam spot on target during irradiation. The cameras will be placed off the beam axis offset in vertical direction. We explored typical shielding arrangements for the cameras and report themore » resulting neutron and photon dose fields.« less

  5. A comparison between rib fracture patterns in peri- and post-mortem compressive injury in a piglet model.

    PubMed

    Bradley, Amanda L; Swain, Michael V; Neil Waddell, J; Das, Raj; Athens, Josie; Kieser, Jules A

    2014-05-01

    Forensic biomechanics is increasingly being used to explain how observed injuries occur. We studied infant rib fractures from a biomechanical and morphological perspective using a porcine model. We used 24, 6th ribs of one day old domestic pigs Sus scrofa, divided into three groups, desiccated (representing post-mortem trauma), fresh ribs with intact periosteum (representing peri-mortem trauma) and those stored at -20°C. Two experiments were designed to study their biomechanical behaviour fracture morphology: ribs were axially compressed and subjected to four-point bending in an Instron 3339 fitted with custom jigs. Morphoscopic analysis of resultant fractures consisted of standard optical methods, micro-CT (μCT) and Scanning Electron Microscopy (SEM). During axial compression fresh ribs did not fracture because of energy absorption capabilities of their soft and fluidic components. In flexure tests, dry ribs showed typical elastic-brittle behaviour with long linear load-extension curves, followed by short non-linear elastic (hyperelastic) behaviour and brittle fracture. Fresh ribs showed initial linear-elastic behaviour, followed by strain softening and visco-plastic responses. During the course of loading, dry bone showed minimal observable damage prior to the onset of unstable fracture. Frozen then thawed bone showed similar patterns to fresh bone. Morphologically, fresh ribs showed extensive periosteal damage to the tensile surface with areas of collagen fibre pull-out along the tensile surface. While all dry ribs fractured precipitously, with associated fibre pull-out, the latter feature was absent in thawed ribs. Our study highlights the fact that under controlled loading, fresh piglet ribs (representing perimortem trauma) did not fracture through bone, but was associated with periosteal tearing. These results suggest firstly, that complete lateral rib fracture in infants may in fact not result from pure compression as has been previously assumed; and secondly, that freezing of bone during storage may affect its fracture behaviour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Analysis of bone healing in flail chest injury: do we need to fix both fractures per rib?

    PubMed

    Marasco, Silvana; Liew, Susan; Edwards, Elton; Varma, Dinesh; Summerhayes, Robyn

    2014-09-01

    Surgical rib fixation (SRF) for severe rib fracture injuries is generating increasing interest in the medical literature. It is well documented that poorly healed fractured ribs can lead to chronic pain, disability, and deformity. An unanswered question in SRF for flail chest injury is whether it is sufficient to fix one fracture per rib, on successive ribs, thus converting a flail chest injury into simple fractured ribs, or whether both ends of the floating segment of the chest wall should be fixed. This study aimed to analyze SRF in flail chest injury, assessing 3-month outcomes for nonfixed fractured rib ends in the flail segment. This is a retrospective review (2005-2013) of 60 consecutive patients who underwent SRF for flail chest injury admitted to the Alfred Hospital, Melbourne, Australia. Imaging by three-dimensional computed tomography (3D CT) of the chest at admission was compared with follow-up 3D CT at 3 months after injury. The 3-month CT scans were assessed for degree of healing and presence of residual deformity at the fracture fixation site. Follow-up CT was performed in 52 of the 60 patients. At 3 months after surgery, 86.5% of the patients had at least partial healing with good alignment and adequate fracture stabilization. Hardware failure was noted in five patients (9.6%) and occurred with the absorbable prostheses only. Six patients who had preoperative overlapping or displacement showed no improvement in deformity despite fixing the lateral fractures. Callus formation and bony bridging between adjacent ribs was often noted in the rib fractures not fixed (28 of 52 patients, 54%) This retrospective review of 3D CT chest at 3 months after rib fixation indicates that a philosophy of fixing only one fracture per rib in a flail segment does not avoid deformity and displacement, particularly in posterior rib fractures. Therapeutic study, level V; epidemiologic study, level V.

  7. WRAP-RIB antenna technology development

    NASA Technical Reports Server (NTRS)

    Freeland, R. E.; Garcia, N. F.; Iwamoto, H.

    1985-01-01

    The wrap-rib deployable antenna concept development is based on a combination of hardware development and testing along with extensive supporting analysis. The proof-of-concept hardware models are large in size so they will address the same basic problems associated with the design fabrication, assembly and test as the full-scale systems which were selected to be 100 meters at the beginning of the program. The hardware evaluation program consists of functional performance tests, design verification tests and analytical model verification tests. Functional testing consists of kinematic deployment, mesh management and verification of mechanical packaging efficiencies. Design verification consists of rib contour precision measurement, rib cross-section variation evaluation, rib materials characterizations and manufacturing imperfections assessment. Analytical model verification and refinement include mesh stiffness measurement, rib static and dynamic testing, mass measurement, and rib cross-section characterization. This concept was considered for a number of potential applications that include mobile communications, VLBI, and aircraft surveillance. In fact, baseline system configurations were developed by JPL, using the appropriate wrap-rib antenna, for all three classes of applications.

  8. The contribution of rib fractures to chronic pain and disability.

    PubMed

    Gordy, Stephanie; Fabricant, Loic; Ham, Bruce; Mullins, Richard; Mayberry, John

    2014-05-01

    The contribution of rib fractures to chronic pain and disability is not well described. Two hundred three patients with rib fractures were followed for 6 months. Chronic pain was assessed using the McGill Pain Questionnaire Pain Rating Index and Present Pain Intensity (PPI) scales. Disability was defined as a decrease in work or functional status. The prevalence of chronic pain was 22% and disability was 53%. Acute PPI predicted chronic pain. Associated injuries, bilateral rib fractures, injury severity score, and number of rib fractures were not predictive of chronic pain. No acute injury characteristics were predictive of disability. Among 89 patients with isolated rib fractures, the prevalence of chronic pain was 28% and of disability was 40%. No injury characteristics predicted chronic pain. Bilateral rib fractures and acute PPI predicted disability. The contribution of rib fractures to chronic pain and disability is significant but unpredictable with conventional injury descriptors. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Compressive rib fracture: peri-mortem and post-mortem trauma patterns in a pig model.

    PubMed

    Kieser, Jules A; Weller, Sarah; Swain, Michael V; Neil Waddell, J; Das, Raj

    2013-07-01

    Despite numerous studies on high impact fractures of ribs, little is known about compressive rib injuries. We studied rib fractures from a biomechanical and morphological perspective using 15, 5th ribs of domestic pigs Sus scrofa, divided into two groups, desiccated (representing post-mortem trauma) and fresh ribs with intact periosteum (representing peri-mortem trauma). Ribs were axially compressed and subjected to four-point bending in an Instron 3339 fitted with custom jigs. Morphoscopic analysis of resultant fractures consisted of standard optical methods, micro-CT (μCT) and scanning electron microscopy (SEM). During axial compression, fresh ribs had slightly higher strength because of energy absorption capabilities of their soft and fluidic components. In flexure tests, dry ribs showed typical elastic-brittle behaviour with long linear load-extension curves, followed by relatively short non-linear elastic (hyperelastic) behaviour and brittle fracture. Fresh ribs showed initial linear-elastic behaviour, followed by strain softening, visco-plastic responses. During the course of loading, dry bone showed minimal observable damage prior to the onset of unstable fracture. In contrast, fresh bone showed buckling-like damage features on the compressive surface and cracking parallel to the axis of the bone. Morphologically, all dry ribs fractured precipitously, whereas all but one of the fresh ribs showed incomplete fracture. The mode of fracture, however, was remarkably similar for both groups, with butterfly fractures predominating (7/15, 46.6% dry and wet). Our study highlights the fact that under controlled loading, despite seemingly similar butterfly fracture morphology, fresh ribs (representing perimortem trauma) show a non-catastrophic response. While extensive strain softening observed for the fresh bone does show some additional micro-cracking damage, it appears that the periosteum may play a key role in imparting the observed pseudo-ductility to the ribs. The presence of fibrous pull-out and grooving of the outer tensile surface associated with periosteal stretching suggests that the periosteum under tension is able to sustain very high strain and bridge the mouth of the extending butterfly crack, thereby contributing to the observed strain-softening behaviour. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Rib plating of acute and sub-acute non-union rib fractures in an adult with cystic fibrosis: a case report.

    PubMed

    Dean, Nathan C; Van Boerum, Don H; Liou, Theodore G

    2014-10-01

    Rib fractures associated with osteoporosis have been reported to occur ten times more frequently in adults with cystic fibrosis. Fractures cause chest pain, and interfere with cough and sputum clearance leading to worsened lung function and acute exacerbations which are the two main contributors to early mortality in cystic fibrosis. Usual treatment involves analgesics and time for healing; however considerable pain and disability result due to constant re-injury from chronic repetitive cough. Recently, surgical plating of rib fractures has become commonplace in treating acute, traumatic chest injuries. We describe here successful surgical plating in a White cystic fibrosis patient with multiple, non-traumatic rib fractures. A-37-year old White male with cystic fibrosis was readmitted to Intermountain Medical Center for a pulmonary exacerbation. He had developed localized rib pain while coughing 2 months earlier, with worsening just prior to hospital admission in conjunction with a "pop" in the same location while bending over. A chest computerized tomography scan at admission demonstrated an acute 5th rib fracture and chronic non-united 6th and 7th right rib fractures. An epidural catheter was placed both for analgesia and to make secretion clearance possible in preparation for the surgery performed 2 days later. Under general anesthesia, he had open reduction and internal fixation of the right 5th, 6th and 7th rib fractures with a Synthes Matrix rib set. After several days of increased oxygen requirements, fever, fluid retention, and borderline vital signs, he stabilized. Numerical pain rating scores from his ribs were lower post-operatively and he was able to tolerate chest physical therapy and vigorous coughing. In our case report, rib plating with bone grafting improved rib pain and allowed healing of the fractures and recovery, although the immediate post-op period required close attention and care. We believe repair may be of benefit in selected cystic fibrosis patients, such as our patient who had suffered multiple rib fractures that were healing poorly.

  11. Microscopic study of heavy-ion reactions with n-rich nuclei: dynamic excitation energy and capture

    NASA Astrophysics Data System (ADS)

    Oberacker, Volker; Umar, A. S.

    2010-11-01

    Heavy-ion reactions at RIB facilities allow us to form new exotic neutron-rich nuclei. These experiments present numerous challenges for a microscopic theoretical description. We study reactions between neutron-rich ^132Sn nuclei and ^96Zr within a dynamic microscopic theory, and we compare the properties to those of the stable system ^124Sn+^96Zr. The calculations are carried out on a 3-D lattice using the density-constrained Time-Dependent Hartree-Fock (DC-TDHF) method [1- 3]. In particular, we calculate the dynamic excitation energy E^*(t) and the quadrupole moment of the dinuclear system Q20(t) during the initial stages of the collision. Regarding the heavy-ion interaction potential V(R), we find that the fusion barrier height and width increase dramatically with increasing beam energy. The fusion barriers of the neutron-rich system ^132Sn+^96Zr are systematically 1-2 MeV higher than those of the stable system. Large differences (9 MeV) are found in the interaction barriers of the two systems. Capture cross sections are analyzed in terms of dynamic effects and a comparison with recently measured capture-fission data is given. [1] Umar and Oberacker, PRC 76, 014614 (2007). [2] Umar, Oberacker, Maruhn, and Reinhard, PRC 80, 041601(R) (2009). [3] Umar, Maruhn, Itagaki, and Oberacker, PRL 104, 212503 (2010).

  12. Fixation of a human rib by an intramedullary telescoping splint anchored by bone cement.

    PubMed

    Liovic, Petar; Šutalo, Ilija D; Marasco, Silvana F

    2016-09-01

    A novel concept for rib fixation is presented that involves the use of a bioresorbable polymer intramedullary telescoping splint. Bone cement is used to anchor each end of the splint inside the medullary canal on each side of the fracture site. In this manner, rib fixation is achieved without fixation device protrusion from the rib, making the splint completely intramedullary. Finite element analysis is used to demonstrate that such a splint/cement composite can preserve rib fixation subjected to cough-intensity force loadings. Computational fluid dynamics and porcine rib experiments were used to study the anchor formation process required to complete the fixation.

  13. Delayed massive hemothorax complicating simple rib fracture associated with diaphragmatic injury.

    PubMed

    Chen, Chin-Li; Cheng, Yeung-Leung

    2014-07-01

    Traumatic hemothorax is potentially life threatening. Rib fractures are the commonest injury after chest trauma, which accounts for 10% of patients after trauma. A delayed massive hemothorax after simple rib fracture is rare. The possibility of delayed sequelae after chest trauma should be considered, and patients should be informed of this possibility. We present a case of this uncommon situation with delayed massive hemothorax caused by simple fracture of the lower ribs. Admission should be considered for close observation when presenting with fracture of the lower ribs because of the possibility of diaphragmatic injury or intra-abdominal injury, even if a simple rib fracture is found initially.

  14. A statistical human rib cage geometry model accounting for variations by age, sex, stature and body mass index.

    PubMed

    Shi, Xiangnan; Cao, Libo; Reed, Matthew P; Rupp, Jonathan D; Hoff, Carrie N; Hu, Jingwen

    2014-07-18

    In this study, we developed a statistical rib cage geometry model accounting for variations by age, sex, stature and body mass index (BMI). Thorax CT scans were obtained from 89 subjects approximately evenly distributed among 8 age groups and both sexes. Threshold-based CT image segmentation was performed to extract the rib geometries, and a total of 464 landmarks on the left side of each subject׳s ribcage were collected to describe the size and shape of the rib cage as well as the cross-sectional geometry of each rib. Principal component analysis and multivariate regression analysis were conducted to predict rib cage geometry as a function of age, sex, stature, and BMI, all of which showed strong effects on rib cage geometry. Except for BMI, all parameters also showed significant effects on rib cross-sectional area using a linear mixed model. This statistical rib cage geometry model can serve as a geometric basis for developing a parametric human thorax finite element model for quantifying effects from different human attributes on thoracic injury risks. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Surgical Management of Rib Fractures: Strategies and Literature Review.

    PubMed

    de Jong, M B; Kokke, M C; Hietbrink, F; Leenen, L P H

    2014-06-01

    Rib fractures can cause significant problems in trauma patients, often resulting in pain and difficulty with respiration. To prevent pulmonary complications and decrease the morbidity and mortality rates of patients with rib fractures, currently there is a trend to provide surgical management of patients with flail chest. However, the indications for rib fracture fixation require further specification. Past and current strategies are described according to a review of the medical literature. A systematic review was performed including current indications for rib fracture fixation. MEDLINE (2000-2013) was searched, as well as Embase (2000-2013) and Cochrane Databases, using the keywords rib, fracture, fixation, plate, repair, and surgery. Three retrospective studies were found that described different techniques for rib fracture fixation. The results demonstrated a reduced number of ventilation days, decreased long-term morbidity and pain, and satisfactory rehabilitation after surgical treatment. In addition to flail chest, age, Injury Severity Score, and the number of rib fractures were important predictive factors for morbidity and mortality. Surgical rib fracture fixation might be indicated in a broader range of cases than is currently performed. Prospective randomized trials are needed for further confirmation. © The Finnish Surgical Society 2014.

  16. High intensity neutrino oscillation facilities in Europe

    DOE PAGES

    Edgecock, T. R.; Caretta, O.; Davenne, T.; ...

    2013-02-20

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ + and μ – beams in a storage ring. The far detector in thismore » case is a 100 kt magnetized iron neutrino detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. Furthermore, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.« less

  17. Development of a collinear laser spectrometer facility at VECC: First test result

    NASA Astrophysics Data System (ADS)

    Ali, Md Sabir; Ray, Ayan; Raja, Waseem; Bandyopadhyay, Arup; Naik, Vaishali; Polley, Asish; Chakrabarti, Alok

    2018-04-01

    We report here the development of collinear laser spectroscopy (CLS) system at VECC for the study of hyperfine spectrum and isotopic shift of stable and unstable isotopes. The facility is first of its kind in the country allowing measurement of hyperfine splitting of atomic levels using atomic beams. The CLS system is installed downstream of the focal plane of the existing isotope separator online (ISOL) facility at VECC and is recently commissioned by successfully resolving the fluorescence spectrum of the hyperfine levels in ^{85,87}Rb. The atomic beams of Rb were produced by charge exchange of 8 keV Rb ion beam which were produced, extracted and transported to the charge exchange cell using the ion sources, extractor and the beam-line magnets of the ISOL facility. The laser propagating opposite to the ion / atom beam direction was allowed to interact with the atom beam and fluorescence spectrum was recorded. The experimental set-up and the experiment conducted are reported in detail. The measures needed to be carried out for improving the sensitivity to a level necessary for studying short-lived exotic nuclei have also been discussed.

  18. Electron cyclotron resonance ion sources in use for heavy ion cancer therapy.

    PubMed

    Tinschert, K; Iannucci, R; Lang, R

    2008-02-01

    The use of electron cyclotron resonance (ECR) ion sources for producing ion beams for heavy ion cancer therapy has been established for more than ten years. After the Heavy Ion Medical Accelerator (HIMAC) at Chiba, Japan started therapy of patients with carbon ions in 1994 the first carbon ion beam for patient treatment at the accelerator facility of GSI was delivered in 1997. ECR ion sources are the perfect tool for providing the required ion beams with good stability, high reliability, and easy maintenance after long operating periods. Various investigations were performed at GSI with different combinations of working gas and auxiliary gas to define the optimal beam conditions for an extended use of further ion species for the dedicated Heidelberg Ion Beam Therapy (HIT) facility installed at the Radiological University Hospital Heidelberg, Germany. Commercially available compact all permanent magnet ECR ion sources operated at 14.5 GHz were chosen for this facility. Besides for (12)C(4+) these ion sources are used to provide beams of (1)H(3)(1+), (3)He(1+), and (16)O(6+). The final commissioning at the HIT facility could be finished at the end of 2006.

  19. Ion Beam Facilities at the National Centre for Accelerator based Research using a 3 MV Pelletron Accelerator

    NASA Astrophysics Data System (ADS)

    Trivedi, T.; Patel, Shiv P.; Chandra, P.; Bajpai, P. K.

    A 3.0 MV (Pelletron 9 SDH 4, NEC, USA) low energy ion accelerator has been recently installed as the National Centre for Accelerator based Research (NCAR) at the Department of Pure & Applied Physics, Guru Ghasidas Vishwavidyalaya, Bilaspur, India. The facility is aimed to carried out interdisciplinary researches using ion beams with high current TORVIS (for H, He ions) and SNICS (for heavy ions) ion sources. The facility includes two dedicated beam lines, one for ion beam analysis (IBA) and other for ion implantation/ irradiation corresponding to switching magnet at +20 and -10 degree, respectively. Ions with 60 kV energy are injected into the accelerator tank where after stripping positively charged ions are accelerated up to 29 MeV for Au. The installed ion beam analysis techniques include RBS, PIXE, ERDA and channelling.

  20. A possible biomedical facility at the European Organization for Nuclear Research (CERN).

    PubMed

    Dosanjh, M; Jones, B; Myers, S

    2013-05-01

    A well-attended meeting, called "Brainstorming discussion for a possible biomedical facility at CERN", was held by the European Organization for Nuclear Research (CERN) at the European Laboratory for Particle Physics on 25 June 2012. This was concerned with adapting an existing, but little used, 78-m circumference CERN synchrotron to deliver a wide range of ion species, preferably from protons to at least neon ions, with beam specifications that match existing clinical facilities. The potential extensive research portfolio discussed included beam ballistics in humanoid phantoms, advanced dosimetry, remote imaging techniques and technical developments in beam delivery, including gantry design. In addition, a modern laboratory for biomedical characterisation of these beams would allow important radiobiological studies, such as relative biological effectiveness, in a dedicated facility with standardisation of experimental conditions and biological end points. A control photon and electron beam would be required nearby for relative biological effectiveness comparisons. Research beam time availability would far exceed that at other facilities throughout the world. This would allow more rapid progress in several biomedical areas, such as in charged hadron therapy of cancer, radioisotope production and radioprotection. The ethos of CERN, in terms of open access, peer-reviewed projects and governance has been so successful for High Energy Physics that application of the same to biomedicine would attract high-quality research, with possible contributions from Europe and beyond, along with potential new funding streams.

  1. A possible biomedical facility at the European Organization for Nuclear Research (CERN)

    PubMed Central

    Dosanjh, M; Myers, S

    2013-01-01

    A well-attended meeting, called “Brainstorming discussion for a possible biomedical facility at CERN”, was held by the European Organization for Nuclear Research (CERN) at the European Laboratory for Particle Physics on 25 June 2012. This was concerned with adapting an existing, but little used, 78-m circumference CERN synchrotron to deliver a wide range of ion species, preferably from protons to at least neon ions, with beam specifications that match existing clinical facilities. The potential extensive research portfolio discussed included beam ballistics in humanoid phantoms, advanced dosimetry, remote imaging techniques and technical developments in beam delivery, including gantry design. In addition, a modern laboratory for biomedical characterisation of these beams would allow important radiobiological studies, such as relative biological effectiveness, in a dedicated facility with standardisation of experimental conditions and biological end points. A control photon and electron beam would be required nearby for relative biological effectiveness comparisons. Research beam time availability would far exceed that at other facilities throughout the world. This would allow more rapid progress in several biomedical areas, such as in charged hadron therapy of cancer, radioisotope production and radioprotection. The ethos of CERN, in terms of open access, peer-reviewed projects and governance has been so successful for High Energy Physics that application of the same to biomedicine would attract high-quality research, with possible contributions from Europe and beyond, along with potential new funding streams. PMID:23549990

  2. The radioactive beam facility ALTO

    NASA Astrophysics Data System (ADS)

    Essabaa, Saïd; Barré-Boscher, Nicole; Cheikh Mhamed, Maher; Cottereau, Evelyne; Franchoo, Serge; Ibrahim, Fadi; Lau, Christophe; Roussière, Brigitte; Saïd, Abdelhakim; Tusseau-Nenez, Sandrine; Verney, David

    2013-12-01

    The Transnational Access facility ALTO (TNA07-ENSAR/FP7) has been commissioned and received from the French safety authorities, the operation license. It is allowed to run at nominal intensity to produce 1011 fissions/s in a thick uranium carbide target by photo-fission using a 10 μA, 50 MeV electron beam. In addition the recent success in operating the selective laser ion source broadens the physics program with neutron-rich nuclear beams possible at this facility installed at IPN Orsay. The facility also aims at being a test bench for the SPIRAL2 project. In that framework an ambitious R&D program on the target ion source system is being developed.

  3. Surgical Stabilization of Rib Fractures in a 6-Year-Old Child After Blunt Trauma.

    PubMed

    Abdelsattar, Zaid M; Ishitani, Michael B; Kim, Brian D

    2017-12-01

    When identified, rib fractures in children are associated with high-energy trauma, nonaccidental trauma, or both. Traditionally, the optimal management of rib fractures in children is supportive care. In this case report, we present a 6-year-old boy who underwent surgical rib fixation for multiple displaced and comminuted rib fractures after being stepped on by a horse. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Detection and labeling ribs on expiration chest radiographs

    NASA Astrophysics Data System (ADS)

    Park, Mira; Jin, Jesse S.; Wilson, Laurence S.

    2003-06-01

    Typically, inspiration is preferred when xraying the lungs. The x-ray technologist will ask a patient to be still and to take a deep breath and to hold it. This not only reduces the possibility of a blurred image but also enhances the quality of the image since air-filled lungs are easier to see on x-ray film. However, inspiration causes low density in the inner part of lung field. That means that ribs in the inner part of lung field have lower density than the other parts nearer to the border of the lung field. That is why edge detection algorithms often fail to detect ribs. Therefore to make rib edges clear we try to produce an expiration lung field using a 'hemi-elliptical cavity.' Based on the expiration lung field, we extract the rib edges using canny edge detector and a new connectivity method, called '4 way with 10-neighbors connectivity' to detect clavicle and rib edge candidates. Once the edge candidates are formed, our system selects the best candidates using knowledge-based constraints such as a gradient, length and location. The edges can be paired and labeled as superior rib edge and inferior rib edge. Then the system uses the clavicle, which is obtained in a same method for the rib edge detection, as a landmark to label all detected ribs.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gündoğan, M. Tural, E-mail: mugetural@yahoo.com; Yavaş, Ö., E-mail: yavas@ankara.edu.tr; Kaya, Ç., E-mail: c.kaya@ankara.edu.tr

    Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC.more » The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.« less

  6. Carbon Beam Radio-Therapy and Research Activities at HIMAC

    NASA Astrophysics Data System (ADS)

    Kanazawa, Mitsutaka

    2007-05-01

    Radio-therapy with carbon ion beam has been carried out since 1994 at HIMAC (Heavy Ion Medical Accelerator in Chiba) in NIRS (National Institute of Radiological Sciences). Now, many types of tumors can be treated with carbon beam with excellent local controls of the tumors. Stimulated with good clinical results, requirement of the dedicated compact facility for carbon beam radio-therapy is increased. To realize this requirement, design study of the facility and the R&D's of the key components in this design are promoted by NIRS. According successful results of these activities, the dedicated compact facility will be realized in Gunma University. In this facility, the established irradiation method is expected to use, which is passive irradiation method with wobbler magnets and ridge filter. In this presentation, above R&D's will be presented together with clinical results and basic research activities at HIMAC.

  7. Proton Therapy Facility Planning From a Clinical and Operational Model.

    PubMed

    Das, Indra J; Moskvin, Vadim P; Zhao, Qingya; Cheng, Chee-Wai; Johnstone, Peter A

    2015-10-01

    This paper provides a model for planning a new proton therapy center based on clinical data, referral pattern, beam utilization and technical considerations. The patient-specific data for the depth of targets from skin in each beam angle were reviewed at our center providing megavoltage photon external beam and proton beam therapy respectively. Further, data on insurance providers, disease sites, treatment depths, snout size and the beam angle utilization from the patients treated at our proton facility were collected and analyzed for their utilization and their impact on the facility cost. The most common disease sites treated at our center are head and neck, brain, sarcoma and pediatric malignancies. From this analysis, it is shown that the tumor depth from skin surface has a bimodal distribution (peak at 12 and 26 cm) that has significant impact on the maximum proton energy, requiring the energy in the range of 130-230 MeV. The choice of beam angles also showed a distinct pattern: mainly at 90° and 270°; this indicates that the number of gantries may be minimized. Snout usage data showed that 70% of the patients are treated with 10 cm snouts. The cost of proton beam therapy depends largely on the type of machine, maximum beam energy and the choice of gantry versus fixed beam line. Our study indicates that for a 4-room center, only two gantry rooms could be needed at the present pattern of the patient cohorts, thus significantly reducing the initial capital cost. In the USA, 95% and 100% of patients can be treated with 200 and 230 MeV proton beam respectively. Use of multi-leaf collimators and pencil beam scanning may further reduce the operational cost of the facility. © The Author(s) 2014.

  8. Low energy ion beam dynamics of NANOGAN ECR ion source

    NASA Astrophysics Data System (ADS)

    Kumar, Sarvesh; Mandal, A.

    2016-04-01

    A new low energy ion beam facility (LEIBF) has been developed for providing the mass analyzed highly charged intense ion beams of energy ranging from a few tens of keV to a few MeV for atomic, molecular and materials sciences research. The new facility consists of an all permanent magnet 10 GHz electron cyclotron resonance (ECR) ion source (NANOGAN) installed on a high voltage platform (400 kV) which provides large currents of multiply charged ion beams. Higher emittance at low energy of intense ion beam puts a tremendous challenge to the beam optical design of this facility. The beam line consists of mainly the electrostatic quadrupoles, an accelerating section, analyzing cum switching magnet and suitable beam diagnostics including vacuum components. The accelerated ion beam is analyzed for a particular mass to charge (m/q) ratio as well as guided to three different lines along 75°, 90° and 105° using a large acceptance analyzing cum switching magnet. The details of transverse beam optics to all the beam lines with TRANSPORT and GICOSY beam optics codes are being described. Field computation code, OPERA 3D has been utilized to design the magnets and electrostatic quadrupoles. A theoretical estimation of emittance for optimized geometry of ion source is given so as to form the basis of beam optics calculations. The method of quadrupole scan of the beam is used to characterize the emittance of the final beam on the target. The measured beam emittance increases with m/q ratios of various ion beams similar to the trend observed theoretically.

  9. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT

    PubMed Central

    Cho, S H; Sung, Y M; Kim, M S

    2012-01-01

    Objective The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. Methods 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. Results 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Conclusion Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images. PMID:22514102

  10. A unified bond theory, probabilistic meso-scale modeling, and experimental validation of deformed steel rebar in normal strength concrete

    NASA Astrophysics Data System (ADS)

    Wu, Chenglin

    Bond between deformed rebar and concrete is affected by rebar deformation pattern, concrete properties, concrete confinement, and rebar-concrete interfacial properties. Two distinct groups of bond models were traditionally developed based on the dominant effects of concrete splitting and near-interface shear-off failures. Their accuracy highly depended upon the test data sets selected in analysis and calibration. In this study, a unified bond model is proposed and developed based on an analogy to the indentation problem around the rib front of deformed rebar. This mechanics-based model can take into account the combined effect of concrete splitting and interface shear-off failures, resulting in average bond strengths for all practical scenarios. To understand the fracture process associated with bond failure, a probabilistic meso-scale model of concrete is proposed and its sensitivity to interface and confinement strengths are investigated. Both the mechanical and finite element models are validated with the available test data sets and are superior to existing models in prediction of average bond strength (< 6% error) and crack spacing (< 6% error). The validated bond model is applied to derive various interrelations among concrete crushing, concrete splitting, interfacial behavior, and the rib spacing-to-height ratio of deformed rebar. It can accurately predict the transition of failure modes from concrete splitting to rebar pullout and predict the effect of rebar surface characteristics as the rib spacing-to-height ratio increases. Based on the unified theory, a global bond model is proposed and developed by introducing bond-slip laws, and validated with testing of concrete beams with spliced reinforcement, achieving a load capacity prediction error of less than 26%. The optimal rebar parameters and concrete cover in structural designs can be derived from this study.

  11. TSR: A storage and cooling ring for HIE-ISOLDE

    NASA Astrophysics Data System (ADS)

    Butler, P. A.; Blaum, K.; Davinson, T.; Flanagan, K.; Freeman, S. J.; Grieser, M.; Lazarus, I. H.; Litvinov, Yu. A.; Lotay, G.; Page, R. D.; Raabe, R.; Siesling, E.; Wenander, F.; Woods, P. J.

    2016-06-01

    It is planned to install the heavy-ion, low-energy ring TSR, currently at the Max-Planck-Institute for Nuclear Physics in Heidelberg, at the HIE-ISOLDE facility in CERN, Geneva. Such a facility will provide a capability for experiments with stored, cooled secondary beams that is rich and varied, spanning from studies of nuclear ground-state properties and reaction studies of astrophysical relevance, to investigations with highly-charged ions and pure isomeric beams. In addition to experiments performed using beams recirculating within the ring, the cooled beams can be extracted and exploited by external spectrometers for high-precision measurements. The capabilities of the ring facility as well as some physics cases will be presented, together with a brief report on the status of the project.

  12. Low emittance lattice for the storage ring of the Turkish Light Source Facility TURKAY

    NASA Astrophysics Data System (ADS)

    Nergiz, Z.; Aksoy, A.

    2015-06-01

    The TAC (Turkish Accelerator Center) project aims to build an accelerator center in Turkey. The first stage of the project is to construct an Infra-Red Free Electron Laser (IR-FEL) facility. The second stage is to build a synchrotron radiation facility named TURKAY, which is a third generation synchrotron radiation light source that aims to achieve a high brilliance photon beam from a low emittance electron beam at 3 GeV. The electron beam parameters are highly dependent on the magnetic lattice of the storage ring. In this paper a low emittance storage ring for TURKAY is proposed and the beam dynamic properties of the magnetic lattice are investigated. Supported by Turkish Republic Ministry of Development (DPT2006K120470)

  13. HiRadMat at CERN SPS - A test facility with high intensity beam pulses to material samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charitonidis, N.; Fabich, A.; Efthymiopoulos, I.

    2015-07-01

    HiRadMat (High Irradiation to Materials) is a facility at CERN designed to provide high-intensity pulsed beams to an irradiation area where material samples as well as accelerator component assemblies (e.g. vacuum windows, shock tests on high power targets, collimators) can be tested. The beam parameters (SPS 440 GeV protons with a pulse energy of up to 3.4 MJ, or alternatively lead/argon ions at the proton equivalent energy) can be tuned to match the needs of each experiment. It is a test area designed to perform single pulse experiments to evaluate the effect of high-intensity pulsed beams on materials in amore » dedicated environment, excluding long-time irradiation studies. The facility is designed for a 10{sup 16} maximum number of protons per year, in order to limit the activation to acceptable levels for human intervention. This paper will demonstrate the possibilities for research using this facility and showing examples of upcoming experiments scheduled in the beam period 2014/2015. (authors)« less

  14. Status and Planned Experiments of the Hiradmat Pulsed Beam Material Test Facility at CERN SPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charitonidis, Nikolaos; Efthymiopoulos, Ilias; Fabich, Adrian

    2015-06-01

    HiRadMat (High Irradiation to Materials) is a facility at CERN designed to provide high-intensity pulsed beams to an irradiation area where material samples as well as accelerator component assemblies (e.g. vacuum windows, shock tests on high power targets, collimators) can be tested. The beam parameters (SPS 440 GeV protons with a pulse energy of up to 3.4 MJ, or alternatively lead/argon ions at the proton equivalent energy) can be tuned to match the needs of each experiment. It is a test area designed to perform single pulse experiments to evaluate the effect of high-intensity pulsed beams on materials in amore » dedicated environment, excluding long-time irradiation studies. The facility is designed for a maximum number of 1016 protons per year, in order to limit the activation of the irradiated samples to acceptable levels for human intervention. This paper will demonstrate the possibilities for research using this facility and go through examples of upcoming experiments scheduled in the beam period 2015/2016.« less

  15. Status of the nuSTORM Facility and a Possible Extension for Long-Baseline $$\

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bross, Alan D.; Liu, Ao; Lagrange, Jean-Baptiste

    2015-11-03

    Neutrino beams produced from the decay of muons in a racetrack-like decay ring (the so called Neutrino Factory) provide a powerful way to study neutrino oscillation physics and, in addition, provide unique beams for neutrino interaction studies. The Neutrinos from STORed Muons (nuSTORM) facility uses a neutrino factory-like design. Due to the particular nature of nuSTORM, it can also provide an intense, very pure, muon neutrino beam from pion decay. This so-called “Neo-conventional" muon neutrino beam from nuSTORM makes nuSTORM a hybrid neutrino factory. In this paper we describe the facility and give a detailed description of the neutrino beammore » fluxes that are available and the precision to which these fluxes can be determined. We then present sensitivity plots that indicated how well the facility can perform for short-baseline oscillation searches and show its potential for a neutrino interaction physics program. Finally, we comment on the performance potential of the "Neo-conventional" muon neutrino beam optimized for long- baseline neutrino-oscillation physics.« less

  16. Overview of the Neutrinos from Stored Muons Facility - nuSTORM

    DOE PAGES

    Adey, D.; Appleby, R. B.; Bayes, R.; ...

    2017-07-19

    Neutrino beams produced from the decay of muons in a racetrack-like decay ring (the so called Neutrino Factory) provide a powerful way to study neutrino oscillation physics and, in addition, provide unique beams for neutrino interaction studies. The Neutrinos from STORed Muons (nuSTORM) facility uses a neutrino factory-like design. Due to the particular nature of nuSTORM, it can also provide an intense, very pure, muon neutrino beam from pion decay. This so-called 'Neo-conventional' muon-neutrino beam from nuSTORM makes nuSTORM a hybrid neutrino factory. Here in this paper we describe the facility and give a detailed description of the neutrino beamsmore » that are available and the precision to which they can be characterized. We then show its potential for a neutrino interaction physics program and present sensitivity plots that indicate how well the facility can perform for short-baseline oscillation searches. Lastly, we comment on the performance potential of a 'Neo-conventional' muon neutrino beam optimized for long-baseline neutrino-oscillation physics.« less

  17. Drive beam stabilisation in the CLIC Test Facility 3

    NASA Astrophysics Data System (ADS)

    Malina, L.; Corsini, R.; Persson, T.; Skowroński, P. K.; Adli, E.

    2018-06-01

    The proposed Compact Linear Collider (CLIC) uses a high intensity, low energy drive beam to produce the RF power needed to accelerate a lower intensity main beam with 100 MV/m gradient. This scheme puts stringent requirements on drive beam stability in terms of phase, energy and current. The consequent experimental work was carried out in CLIC Test Facility CTF3. In this paper, we present a novel analysis technique in accelerator physics to find beam drifts and their sources in the vast amount of the continuously gathered signals. The instability sources are identified and adequately mitigated either by hardware improvements or by implementation and commissioning of various feedbacks, mostly beam-based. The resulting drive beam stability is of 0.2°@ 3 GHz in phase, 0.08% in relative beam energy and about 0.2% beam current. Finally, we propose a stabilisation concept for CLIC to guarantee the main beam stability.

  18. The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Y., E-mail: yjma@ciae.ac.cn; Cui, B.; Ma, R.

    The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will bemore » installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.« less

  19. Computational Investigations in Rectangular Convergent and Divergent Ribbed Channels

    NASA Astrophysics Data System (ADS)

    Sivakumar, Karthikeyan; Kulasekharan, N.; Natarajan, E.

    2018-05-01

    Computational investigations on the rib turbulated flow inside a convergent and divergent rectangular channel with square ribs of different rib heights and different Reynolds numbers (Re=20,000, 40,000 and 60,000). The ribs were arranged in a staggered fashion between the upper and lower surfaces of the test section. Computational investigations are carried out using computational fluid dynamic software ANSYS Fluent 14.0. Suitable solver settings like turbulence models were identified from the literature and the boundary conditions for the simulations on a solution of independent grid. Computations were carried out for both convergent and divergent channels with 0 (smooth duct), 1.5, 3, 6, 9 and 12 mm rib heights, to identify the ribbed channel with optimal performance, assessed using a thermo hydraulic performance parameter. The convergent and divergent rectangular channels show higher Nu values than the standard correlation values.

  20. Preliminary study of rib articulated model based on dynamic fluoroscopy images

    NASA Astrophysics Data System (ADS)

    Villard, Pierre-Frederic; Escamilla, Pierre; Kerrien, Erwan; Gorges, Sebastien; Trousset, Yves; Berger, Marie-Odile

    2014-03-01

    We present in this paper a preliminary study of rib motion tracking during Interventional Radiology (IR) fluoroscopy guided procedures. It consists in providing a physician with moving rib three-dimensional (3D) models projected in the fluoroscopy plane during a treatment. The strategy is to help to quickly recognize the target and the no-go areas i.e. the tumor and the organs to avoid. The method consists in i) elaborating a kinematic model of each rib from a preoperative computerized tomography (CT) scan, ii) processing the on-line fluoroscopy image and iii) optimizing the parameters of the kinematic law such as the transformed 3D rib projected on the medical image plane fit well with the previously processed image. The results show a visually good rib tracking that has been quantitatively validated by showing a periodic motion as well as a good synchronism between ribs.

  1. Microdosimetric investigation at the therapeutic proton beam facility of CATANA.

    PubMed

    De Nardo, L; Moro, D; Colautti, P; Conte, V; Tornielli, G; Cuttone, G

    2004-01-01

    Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Institute of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation quality of two spread-out Bragg peaks (SOBP) at the CATANA proton beam.

  2. Physical mechanisms of active control of sound transmission through rib stiffened double-panel structure

    NASA Astrophysics Data System (ADS)

    Ma, Xiyue; Chen, Kean; Ding, Shaohu; Yu, Haoxin

    2016-06-01

    This paper presents an analytical investigation on physical mechanisms of actively controlling sound transmission through a rib stiffened double-panel structure using point source in the cavity. The combined modal expansion and vibro-acoustic coupling methods are applied to establish the theoretical model of such active structure. Under the condition of minimizing radiated power of the radiating ribbed plate, the physical mechanisms are interpreted in detail from the point of view of modal couplings similar as that used in existed literatures. Results obtained demonstrate that the rule of sound energy transmission and the physical mechanisms for the rib stiffened double-panel structure are all changed, and affected by the coupling effects of the rib when compared with the analytical results obtained for unribbed double-panel case. By taking the coupling effects of the rib into considerations, the cavity modal suppression and rearrangement mechanisms obtained in existed investigations are modified and supplemented for the ribbed plate case, which gives a clear interpretation for the physical nature involved in the active rib stiffened double-panel structure.

  3. What Accounts for Rib Fractures in Older Adults?

    PubMed Central

    Wuermser, Lisa-Ann; Achenbach, Sara J.; Amin, Shreyasee; Khosla, Sundeep; Melton, L. Joseph

    2011-01-01

    To address the epidemiology of rib fractures, an age- and sex-stratified random sample of 699 Rochester, Minnesota, adults age 21–93 years was followed in a long-term prospective study. Bone mineral density (BMD) was assessed at baseline, and fractures were ascertained by periodic interview and medical record review. During 8560 person-years of followup (median, 13.9 years), 56 subjects experienced 67 rib fracture episodes. Risk factors for falling predicted rib fractures as well as BMD, but both were strongly age-related. After age-adjustment, BMD was associated with rib fractures in women but not men. Importantly, rib fractures attributed to severe trauma were associated with BMD in older individuals of both sexes. Self-reported heavy alcohol use doubled fracture risk but did not achieve significance due to limited statistical power. Bone density, along with heavy alcohol use and other risk factors for falling, contributes to the risk of rib fractures, but no one factor predominates. Older women with rib fractures, regardless of cause, should be considered for an osteoporosis evaluation, and strategies to prevent falling should be considered in both sexes. PMID:22028986

  4. What accounts for rib fractures in older adults?

    PubMed

    Wuermser, Lisa-Ann; Achenbach, Sara J; Amin, Shreyasee; Khosla, Sundeep; Melton, L Joseph

    2011-01-01

    To address the epidemiology of rib fractures, an age- and sex-stratified random sample of 699 Rochester, Minnesota, adults age 21-93 years was followed in a long-term prospective study. Bone mineral density (BMD) was assessed at baseline, and fractures were ascertained by periodic interview and medical record review. During 8560 person-years of followup (median, 13.9 years), 56 subjects experienced 67 rib fracture episodes. Risk factors for falling predicted rib fractures as well as BMD, but both were strongly age-related. After age-adjustment, BMD was associated with rib fractures in women but not men. Importantly, rib fractures attributed to severe trauma were associated with BMD in older individuals of both sexes. Self-reported heavy alcohol use doubled fracture risk but did not achieve significance due to limited statistical power. Bone density, along with heavy alcohol use and other risk factors for falling, contributes to the risk of rib fractures, but no one factor predominates. Older women with rib fractures, regardless of cause, should be considered for an osteoporosis evaluation, and strategies to prevent falling should be considered in both sexes.

  5. Simple X-ray versus ultrasonography examination in blunt chest trauma: effective tools of accurate diagnosis and considerations for rib fractures.

    PubMed

    Hwang, Eun Gu; Lee, Yunjung

    2016-12-01

    Simple radiography is the best diagnostic tool for rib fractures caused by chest trauma, but it has some limitations. Thus, other tools are also being used. The aims of this study were to investigate the effectiveness of ultrasonography (US) for identifying rib fractures and to identify influencing factors of its effectiveness. Between October 2003 and August 2007, 201 patients with blunt chest trauma were available to undergo chest radiographic and US examinations for diagnosis of rib fractures. The two modalities were compared in terms of effectiveness based on simple radiographic readings and US examination results. We also investigated the factors that influenced the effectiveness of US examination. Rib fractures were detected on radiography in 69 patients (34.3%) but not in 132 patients. Rib fractures were diagnosed by using US examination in 160 patients (84.6%). Of the 132 patients who showed no rib fractures on radiography, 92 showed rib fractures on US. Among the 69 patients of rib fracture detected on radiography, 33 had additional rib fractures detected on US. Of the patients, 76 (37.8%) had identical radiographic and US results, and 125 (62.2%) had fractures detected on US that were previously undetected on radiography or additional fractures detected on US. Age, duration until US examination, and fracture location were not significant influencing factors. However, in the group without detected fractures on radiography, US showed a more significant effectiveness than in the group with detected fractures on radiography ( P =0.003). US examination could detect unnoticed rib fractures on simple radiography. US examination is especially more effective in the group without detected fractures on radiography. More attention should be paid to patients with chest trauma who have no detected fractures on radiography.

  6. Rib fractures after percutaneous radiofrequency and microwave ablation of lung tumors: incidence and relevance.

    PubMed

    Alexander, Erica S; Hankins, Carol A; Machan, Jason T; Healey, Terrance T; Dupuy, Damian E

    2013-03-01

    To retrospectively identify the incidence and probable risk factors for rib fractures after percutaneous radiofrequency ablation (RFA) and microwave ablation (MWA) of neoplasms in the lung and to identify complications related to these fractures. Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Study population was 163 patients treated with MWA and/or RFA for 195 lung neoplasms between February 2004 and April 2010. Follow-up computed tomographic images of at least 3 months were retrospectively reviewed by board-certified radiologists to determine the presence of rib fractures. Generalized estimating equations were performed to assess the effect that patient demographics, tumor characteristics, treatment parameters, and ablation zone characteristics had on development of rib fractures. Kaplan-Meier curve was used to estimate patients' probability of rib fracture after ablation as a function of time. Clinical parameters (ie, pain in ribs or chest, organ damage caused by fractured rib) were evaluated for patients with confirmed fracture. Rib fractures in proximity to the ablation zone were found in 13.5% (22 of 163) of patients. Estimated probability of fracture was 9% at 1 year and 22% at 3 years. Women were more likely than were men to develop fracture after ablation (P = .041). Patients with tumors closer to the chest wall were more likely to develop fracture (P = .0009), as were patients with ablation zones that involved visceral pleura (P = .039). No patients with rib fractures that were apparently induced by RFA and MWA had organ injury or damage related to fracture, and 9.1% (2 of 22) of patients reported mild pain. Rib fractures were present in 13.5% of patients after percutaneous RFA and MWA of lung neoplasms. Patients who had ablations performed close to the chest wall should be monitored for rib fractures.

  7. Dyspnea, chest wall hyperinflation, and rib cage distortion in exercising patients with chronic obstructive pulmonary disease.

    PubMed

    Bruni, Giulia Innocenti; Gigliotti, Francesco; Binazzi, Barbara; Romagnoli, Isabella; Duranti, Roberto; Scano, Giorgio

    2012-06-01

    Whether dyspnea, chest wall dynamic hyperinflation, and abnormalities of rib cage motion are interrelated phenomena has not been systematically evaluated in patients with chronic obstructive pulmonary disease (COPD). Our hypothesis that they are not interrelated was based on the following observations: (i) externally imposed expiratory flow limitation is associated with no rib cage distortion during strenuous incremental exercise, with indexes of hyperinflation not being correlated with dyspnea, and (ii) end-expiratory chest wall volume may either increase or decrease during exercise in patients with COPD, with those who hyperinflate being as breathless as those who do not. Sixteen patients breathed either room air or 50% supplemental O2 at 75% of peak exercise in randomized order. We evaluated the volume of chest wall (V(cw)) and its compartments: the upper rib cage (V(rcp)), lower rib cage (V(rca)), and abdomen (V(ab)) using optoelectronic plethysmography; rib cage distortion was assessed by measuring the phase angle shift between V(rcp) and V(rca). Ten patients increased end-expiratory V(cw) (V(cw,ee)) on air. In seven hyperinflators and three non-hyperinflators, the lower rib cage paradoxed inward during inspiration with a phase angle of 63.4° ± 30.7° compared with a normal phase angle of 16.1° ± 2.3° recorded in patients without rib cage distortion. Dyspnea (by Borg scale) averaged 8.2 and 9 at the end of exercise on air in patients with and without rib cage distortion, respectively. At iso-time during exercise with oxygen, decreased dyspnea was associated with a decrease in ventilation regardless of whether patients distorted the rib cage, dynamically hyperinflated, or deflated the chest wall. Dyspnea, chest wall dynamic hyperinflation, and rib cage distortion are not interrelated phenomena.

  8. Focusing of high intensity ultrasound through the rib cage using a therapeutic random phased array

    PubMed Central

    Bobkova, Svetlana; Gavrilov, Leonid; Khokhlova, Vera; Shaw, Adam; Hand, Jeffrey; #, ||

    2010-01-01

    A method for focusing high intensity ultrasound through a rib cage that aims to minimize heating of the ribs whilst maintaining high intensities at the focus (or foci) is proposed and tested theoretically and experimentally. Two approaches, one based on geometric acoustics and the other accounting for diffraction effects associated with propagation through the rib cage, are investigated theoretically for idealized source conditions. It is shown that for an idealized radiator the diffraction approach provides a 23% gain in peak intensity and results in significantly less power losses on the ribs (1% versus 7.5% of the irradiated power) compared with the geometric one. A 2D 1-MHz phased array with 254 randomly distributed elements, tissue mimicking phantoms, and samples of porcine rib cages are used in experiments; the geometric approach is used to configure how the array is driven. Intensity distributions are measured in the plane of the ribs and in the focal plane using an infra-red camera. Theoretical and experimental results show that it is possible to provide adequate focusing through the ribs without overheating them for a single focus and several foci, including steering at ± 10–15 mm off and ± 20 mm along the array axis. Focus splitting due to the periodic spatial structure of ribs is demonstrated both in simulations and experiments; the parameters of splitting are quantified. The ability to produce thermal lesions with a split focal pattern in ex vivo porcine tissue placed beyond the rib phantom is also demonstrated. The results suggest that the method is potentially useful for clinical applications of HIFU for which the rib cage lies between the transducer(s) and the targeted tissue. PMID:20510186

  9. First radioactive beams at ACCULINNA-2 facility and first proposed experiment

    NASA Astrophysics Data System (ADS)

    Bezbakh, A. A.; Beekman, W.; Chudoba, V.; Fomichev, A. S.; Golovkov, M. S.; Gorshkov, A. V.; Grigorenko, L. V.; Kaminski, G.; Krupko, S. A.; Mentel, M.; Nikolskii, E. Yu.; Parfenova, Yu. L.; Plucinski, P.; Sidorchuk, S. I.; Slepnev, R. S.; Sharov, P. G.; Ter-Akopian, G. M.; Zalewski, B.

    2018-04-01

    New fragment separator ACCULINNA-2 was installed at the primary beam line of the U-400M cyclotron in 2016. Recently, first radioactive ion beams were obtained. The design parameters of new facility were experimentally confirmed. Intensity, purity and transverse profile of several secondary beams at the final focal plane were studied. The intensities obtained for the secondary beams of 14B, 12Be, 9;11Li, 6;8He in the fragmentation reaction 15N (49.7 AMeV) + Be (2 mm) are in average 15 times higher in comparison to the ones produced at its forerunner ACCULINNA separator. The ACCULINNA-2 separator will become a backbone facility at the FLNR for the research in the field of light exotic nuclei in the vicinity of the nuclear drip lines. The planned first experiment, aimed for the observation of the 7H nucleus at ACCULINNA-2, is outlined.

  10. Beam test of a superconducting cavity for the Fermilab high-brightness electron photo-injector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    W. Hartung, J.P. Carneiro, M. Champion, H. Edwards, J. Fuest, K. Koepke and M. Kuchnir

    1999-05-04

    An electron photo-injector facility has been constructed at Fermilab for the purpose of providing a 14�18 MeV elec-tron beam with high charge per bunch (8 nC), short bunch length (1 mm RMS), and small transverse emittance [1]. The facility was used to commission a second-generation photo-cathode RF gun for the TeSLA Test Facility (TTF) Linac at DESY [2, 3]; in the future, the Fermilab electron beam will be used for R & D in bunch length compres-sion, beam diagnostics, and new acceleration techniques. Acceleration beyond 4 MeV is provided by a 9-cell super-conducting cavity (see Figure 1). The cavity alsomore » provides a longitudinal position-momentum correlation for subse-quent bunch length compression. We report on the RF tests and a first beam test of this cavity.« less

  11. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images.

    PubMed

    Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2016-05-20

    To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.

  12. Design update and recent results of the Apollon 10 PW facility

    NASA Astrophysics Data System (ADS)

    Le Garrec, B.; Papadopoulos, D. N.; Le Blanc, C.; Zou, J. P.; Chériaux, G.; Georges, P.; Druon, F.; Martin, L.; Fréneaux, L.; Beluze, A.; Lebas, N.; Mathieu, F.; Audebert, P.

    2017-05-01

    In this paper we are giving a summary of the Apollon 10 PW facility laser design together with updated laser performance. The Apollon facility is currently under construction in France. The APOLLON laser system is a laser designed for delivering pulses as short as 15 fs (10-15 s) with an energy exceeding 150 Joules on target. The peak power delivered by this laser system will be 10 Petawatts (1016W). The Apollon laser system will be delivering 4 beams: one 10 PW beam (F1 beam 400 mm diameter), one 1 PW beam (F2 beam 140 mm diameter) and two additional probe beams (F3 and F4) at a repetition rate of 1 shot per minute. The laser system is based on Ti-sapphire amplifiers pumped by frequency doubled solid-state lasers. The repetition rate of the high energy part will be 1 shot per minute. The main beam at the output of the last amplifier will be split and dispatched to two experimental areas. The main laser beam is delivering 30 J before compression at a repetition rate of 1 shot per minute and we are currently increasing to get 100J.

  13. Trauma patient adverse outcomes are independently associated with rib cage fracture burden and severity of lung, head, and abdominal injuries.

    PubMed

    Dunham, C Michael; Hileman, Barbara M; Ransom, Kenneth J; Malik, Rema J

    2015-01-01

    We hypothesized that lung injury and rib cage fracture quantification would be associated with adverse outcomes. Consecutive admissions to a trauma center with Injury Severity Score ≥ 9, age 18-75, and blunt trauma. CT scans were reviewed to score rib and sternal fractures and lung infiltrates. Sternum and each anterior, lateral, and posterior rib fracture was scored 1 = non-displaced and 2 = displaced. Rib cage fracture score (RCFS) = total rib fracture score + sternal fracture score + thoracic spine Abbreviated Injury Score (AIS). Four lung regions (right upper/middle, right lower, left upper, and left lower lobes) were each scored for % of infiltrate: 0% = 0; ≤ 20% = 1, ≤ 50% = 2, > 50% = 3; total of 4 scores = lung infiltrate score (LIS). Of 599 patients, 193 (32%) had 854 rib fractures. Rib fracture patients had more abdominal injuries (p < 0.001), hemo/pneumothorax (p < 0.001), lung infiltrates (p < 0.001), thoracic spine injuries (p = 0.001), sternal fractures (p = 0.0028) and death or need for mechanical ventilation ≥ 3 days (Death/Vdays ≥ 3) (p < 0.001). Death/Vdays ≥ 3 was independently associated with RCFS (p < 0.001), LIS (p < 0.001), head AIS (p < 0.001) and abdominal AIS (p < 0.001). Of the 193 rib fracture patients, Glasgow Coma Score 3-12 or head AIS ≥ 2 occurred in 43%. A lung infiltrate or hemo/pneumothorax occurred in 55%. Thoracic spine injury occurred in 23%. RCFS was 6.3 ± 4.4 and Death/Vdays ≥ 3 occurred in 31%. Death/Vdays ≥ 3 rates correlated with RCFS values: 19% for 1-3; 24% for 4-6; 42% for 7-12 and 65% for ≥ 13 (p < 0.001). Death/Vdays ≥ 3 was independently associated with RCFS (p = 0.02), LIS (p = 0.001), head AIS (p < 0.001) and abdominal AIS (p < 0.001). Death/Vdays ≥ 3 association was better for RCFS (p = 0.005) than rib fracture score (p = 0.08) or number of fractured ribs (p = 0.80). Rib fracture patients have increased risk for truncal injuries and adverse outcomes. Adverse outcomes are independently associated with rib cage fracture burden. Severity of head, abdominal, and lung injuries also influence rib fracture outcomes.

  14. Indian Test Facility (INTF) and its updates

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, M.; Chakraborty, A.; Rotti, C.; Joshi, J.; Patel, H.; Yadav, A.; Shah, S.; Tyagi, H.; Parmar, D.; Sudhir, Dass; Gahlaut, A.; Bansal, G.; Soni, J.; Pandya, K.; Pandey, R.; Yadav, R.; Nagaraju, M. V.; Mahesh, V.; Pillai, S.; Sharma, D.; Singh, D.; Bhuyan, M.; Mistry, H.; Parmar, K.; Patel, M.; Patel, K.; Prajapati, B.; Shishangiya, H.; Vishnudev, M.; Bhagora, J.

    2017-04-01

    To characterize ITER Diagnostic Neutral Beam (DNB) system with full specification and to support IPR’s negative ion beam based neutral beam injector (NBI) system development program, a R&D facility, named INTF is under commissioning phase. Implementation of a successful DNB at ITER requires several challenges need to be overcome. These issues are related to the negative ion production, its neutralization and corresponding neutral beam transport over the path lengths of ∼ 20.67 m to reach ITER plasma. DNB is a procurement package for INDIA, as an in-kind contribution to ITER. Since ITER is considered as a nuclear facility, minimum diagnostic systems, linked with safe operation of the machine are planned to be incorporated in it and so there is difficulty to characterize DNB after onsite commissioning. Therefore, the delivery of DNB to ITER will be benefited if DNB is operated and characterized prior to onsite commissioning. INTF has been envisaged to be operational with the large size ion source activities in the similar timeline, as with the SPIDER (RFX, Padova) facility. This paper describes some of the development updates of the facility.

  15. Operating experience with existing light sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barton, M.Q.

    It is instructive to consider what an explosive growth there has been in the development of light sources using synchrotron radiation. This is well illustrated by the list of facilities given in Table I. In many cases, synchrotron light facilities have been obtained by tacking on parasitic beam lines to rings that were built for high energy physics. Of the twenty-three facilities in this table, however, eleven were built explicitely for this synchrotron radiation. Another seven have by now been converted for use as dedicated facilities leaving only five that share time with high energy physics. These five parasitically operatedmore » facilities are still among our best sources of hard x-rays, however, and their importance to the fields of science where these x-rays are needed must be emphasized. While the number of facilities in this table is impressive, it is even more impressive to add up the total number of user beam lines. Most of these rings are absolutely surrounded by beam lines and finding real estate on the experimental floor of one of these facilities for adding a new experiment looks about as practical as adding a farm in the middle of Manhattan. Nonetheless, the managers of these rings seem to have an attitude of ''always room for one more'' and new experimental beam lines do appear. This situation is necessary because the demand for beam time has exploded at an even faster rate than the development of the facilities. The field is not only growing, it can be expected to continue to grow for some time. Some of the explicit plans for future development will be discussed in the companion paper by Lee Teng.« less

  16. Turbine bucket natural frequency tuning rib

    DOEpatents

    Wang, John Zhiqiang; Norton, Paul Francis; Barb, Kevin Joseph; Jacala, Ariel Caesar-Prepena

    2002-01-01

    A tuning rib is added preferably in the aft cavity of a cored turbine bucket to alter the bucket's natural frequencies. The tuning rib may be a solid rib or a segmented rib and is particularly suited for altering high order frequency modes such as 2T, 4F and 1-3S. As such, detrimental crossings of natural bucket frequencies and gas turbine stimuli can be avoided to thereby improve the reliability of a gas turbine without impacting other features of the bucket that are important to the performance of the gas turbine.

  17. Converter target chemistry - A new challenge to radioanalytical chemistry.

    PubMed

    Choudhury, Dibyasree; Lahiri, Susanta

    2018-07-01

    The 1-2 GeV proton induced spallation reaction on the high Z materials like Hg, or lead bismuth eutectic (LBE), popularly known as converter targets, will produce strong flux of fast neutrons which would further react with fissile materials to produce intense radioactive ion beam (RIB). LBE offers suitability for use as converters over Hg but it suffers from the demerit of radiotoxic polonium production. These targets may be viewed as a store house of clinically important and other exotic radionuclides. For application of those radionuclides, radiochemical separation from bulk target material is of utmost importance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Measurement of the 21Na(p,{gamma})22Mg Reaction with the Dragon Facility at TRIUMF-ISAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, A.A.; Bishop, S.; D'Auria, J.M.

    2003-08-26

    The DRAGON recoil separator facility, designed to measure the rates of radiative proton and alpha capture reactions important for nuclear astrophysics, is now operational at the TRIUMF-ISAC radioactive beam facility in Vancouver, Canada. We report on first measurements of the 21Na(p,{gamma})22Mg reaction rate with radioactive beams of 21Na.

  19. Rib fracture - aftercare

    MedlinePlus

    ... Alternative Names Broken rib - aftercare References Browner BD, Jupiter JB, Krettek C, Anderson PA. Scapula and rib fractures. In: Browner BD, Jupiter JB, Krettek C, Anderson PA, eds. Skeletal Trauma: ...

  20. Neutron measurements from beam-target reactions at the ELISE neutral beam test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xufei, X., E-mail: xiexufei@pku.edu.cn; Fan, T.; Nocente, M.

    2014-11-15

    Measurements of 2.5 MeV neutron emission from beam-target reactions performed at the ELISE neutral beam test facility are presented in this paper. The measurements are used to study the penetration of a deuterium beam in a copper dump, based on the observation of the time evolution of the neutron counting rate from beam-target reactions with a liquid scintillation detector. A calculation based on a local mixing model of deuterium deposition in the target up to a concentration of 20% at saturation is used to evaluate the expected neutron yield for comparison with data. The results are of relevance to understandmore » neutron emission associated to beam penetration in a solid target, with applications to diagnostic systems for the SPIDER and MITICA Neutral Beam Injection prototypes.« less

  1. Technical developments for an upgrade of the LEBIT Penning trap mass spectrometry facility for rare isotopes

    NASA Astrophysics Data System (ADS)

    Redshaw, M.; Barquest, B. R.; Bollen, G.; Bustabad, S. E.; Campbell, C. M.; Ferrer, R.; Gehring, A.; Kwiatkowski, A. A.; Lincoln, D. L.; Morrissey, D. J.; Pang, G. K.; Ringle, R.; Schwarz, S.

    2011-07-01

    The LEBIT (Low Energy Beam and Ion Trap) facility is the only Penning trap mass spectrometry (PTMS) facility to utilize rare isotopes produced via fast-beam fragmentation. This technique allows access to practically all elements lighter than uranium, and in particular enables the production of isotopes that are not available or that are difficult to obtain at isotope separation on-line facilities. The preparation of the high-energy rare-isotope beam produced by projectile fragmentation for low-energy PTMS experiments is achieved by gas stopping to slow down and thermalize the fast-beam ions, along with an rf quadrupole cooler and buncher and rf quadrupole ion guides to deliver the beam to the Penning trap. During its first phase of operation LEBIT has been very successful, and new developments are now underway to access rare isotopes even farther from stability, which requires dealing with extremely short lifetimes and low production rates. These developments aim at increasing delivery efficiency, minimizing delivery and measurement time, and maximizing use of available beam time. They include an upgrade to the gas-stopping station, active magnetic field monitoring and stabilization by employing a miniature Penning trap as a magnetometer, the use of stored waveform inverse Fourier transform (SWIFT) to most effectively remove unwanted ions, and charge breeding.

  2. Two-dimensional silicon-based detectors for ion beam therapy

    NASA Astrophysics Data System (ADS)

    Martišíková, M.; Granja, C.; Jakůbek, J.; Hartmann, B.; Telsemeyer, J.; Huber, L.; Brons, S.; Pospíšil, S.; Jäkel, O.

    2012-02-01

    Radiation therapy with ion beams is a highly precise kind of cancer treatment. As ion beams traverse material, the highest ionization density occurs at the end of their path. Due to this Bragg-peak, ion beams enable higher dose conformation to the tumor and increased sparing of the surrounding tissue, in comparison to standard radiation therapy using high energy photons. Ions heavier than protons offer in addition increased biological effectiveness and lower scattering. The Heidelberg Ion Beam Therapy Center (HIT) is a state-of-the-art ion beam therapy facility and the first hospital-based facility in Europe. It provides proton and carbon ion treatments. A synchrotron is used for ion acceleration. For dose delivery to the patient, narrow pencil-like beams are scanned over the target volume.

  3. Activation Levels, Handling, and Storage of Activated Components in the Target Hall at FRIB

    NASA Astrophysics Data System (ADS)

    Georgobiani, D.; Bennett, R.; Bollen, G.; Kostin, M.; Ronningen, R.

    2018-06-01

    The Facility for Rare Isotope Beams (FRIB) is a major new scientific user facility under construction in the United States for nuclear science research with beams of rare isotopes. 400 kW beam operations with heavy ions ranging from oxygen to uranium will create a high radiation environment for many components, particularly for the beam line components located in the target hall, where approximately 100 kW of beam power are dissipated in the target and another 300 kW are dissipated in the beam dump. Detailed studies of the component activation, their remote handling, storage, and transport, have been performed to ensure safe operation levels in this environment. Levels of activation are calculated for the beam line components within the FRIB target hall.

  4. The status of the positron beam facility at NEPOMUC

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, C.

    2011-01-01

    The NEutron induced POsitron source MUniCh NEPOMUC provides a high intensity positron beam with 9·108 moderated positrons per second with a primary beam energy of 1keV. After remoderation, the positron beam is magnetically guided to five experimental setups: a coincident Doppler-broadening spectrometer (CDBS), a positron annihilation induced Auger-electron spectrometer (PAES), a pulsed low-energy positron system (PLEPS) as well as an interface for providing a pulsed beam with further improved brightness. An apparatus for the production of the negatively charged positronium ion Ps- is currently in operation at the open multi-purpose beam port, where additional experiments can be realized. Within this contribution, an overview of the positron beam facility NEPOMUC with its instrumentation at the research reactor FRMII is given.

  5. Use of the Animal Trauma Triage Score, RibScore, Modified RibScore and Other Clinical Factors for Prognostication in Canine Rib Fractures.

    PubMed

    McCarthy, Daniel; Bacek, Lenore; Kim, Kyoung; Miller, George; Gaillard, Philippe; Kuo, Kendon

    2018-06-11

     To characterize the clinical features among dogs sustaining rib fractures and to determine if age, type and severity of injury, entry blood lactate, trauma score and rib fracture score were associated with outcome.  A retrospective study was performed to include dogs that were presented with rib fractures. Risk factors evaluation included breed, age, body weight, diagnosis, presence of a flail chest, bandage use, puncture wound presence, rib fracture number, location of the fracture along the thoracic wall, hospital stay length, body weight, other fractures, pleural effusion, pulmonary contusions, pneumothorax and occurrence of an anaesthetic event. A retrospective calculation of an animal trauma triage (ATT) score, RibScore and Modified RibScore was assigned.  Forty-one medical records were collected. Motor vehicular trauma represented 56% of the rib fracture aetiology, 41% of patients sustained dog bites and one case was of an unknown aetiology. Significant correlations with risk factors were found only with the ATT score. All patients that died had an ATT score ≥ 5. The ATT score correlated positively with mortality ( p  < 0.05) with an ATT score ≥ 7 was 88% sensitive and 81% specific for predicting mortality. A 1-point increase in ATT score corresponded to 2.1 times decreased likelihood of survival. Mean hospital stay was 3 days longer for dog bite cases.  There was no increased mortality rate in canine patients that presented with the suspected risk factors. The only risk factor that predicted mortality was the ATT score. Schattauer GmbH Stuttgart.

  6. The posterior skeletal thorax: rib-vertebral angle and axial vertebral rotation asymmetries in adolescent idiopathic scoliosis.

    PubMed

    Burwell, R G; Aujla, R K; Freeman, B J C; Dangerfield, P H; Cole, A A; Kirby, A S; Polak, F J; Pratt, R K; Moulton, A

    2008-01-01

    The deformity of the ribcage in thoracic adolescent idiopathic scoliosis (AIS) is viewed by most as being secondary to the spinal deformity, though a few consider it primary or involved in curve aggravation. Those who consider it primary ascribe pathogenetic significance to rib-vertebra angle asymmetry. In thoracic AIS, supra-apical rib-vertebra angle differences (RVADs) are reported to be associated with the severity of the Cobb angle. In this paper we attempt to evaluate rib and spinal pathomechanisms in thoracic and thnoracolumbar AIS using spinal radiographs and real-time ultrasound. On the radiographs by costo-vertebral angle asymmetries (rib-vertebral angle differences RVADs, and rib-spinal angle differences RSADs), apical vertebral rotation (AV) and apical vertebral translation (AVT) were measured; and by ultrasound, spine-rib rotation differences (SRRDs) were estimated. RVADs are largest at two and three vertebral levels above the apex where they correlate significantly and positively with Cobb angle and AVT but not AVR. In right thoracic AIS, the cause(s) of the RVA asymmetries is unknown: it may result from trunk muscle imbalance, or from ribs adjusting passively within the constraint of the fourth column of the spine to increasing spinal curvature from whatever cause. Several possible mechanisms may drive axial vertebral rotation including, biplanar spinal asymmetry, relative anterior spinal overgrowth, dorsal shear forces in the presence of normal vertebral axial rotation, asymmetry of rib linear growth, trunk muscle imbalance causing rib-vertebra angle asymmetry weakening the spinal rotation-defending system of bipedal gait, and CNS mechanisms.

  7. Modified rib pivot lateral thoracotomy: a case series.

    PubMed

    Appelgrein, C; Hosgood, G

    2018-01-01

    To describe a modified rib pivot thoracotomy and its clinical application in client-owned dogs and cats. Case series of 24 dogs and 1 cat requiring a thoracotomy. A lateral thoracic incision over the required thoracic segment was made. The latissimus dorsi muscle was reflected dorsally. The predetermined rib was identified and the periosteum overlying the rib was elevated circumferentially, avoiding the intercostal neurovascular structures. Holes were pre-placed above and below the proposed osteotomy site. The rib was osteotomised and pivoted cranially. The pleura was incised and the required intrathoracic procedure was then performed. The thoracic cavity was closed by pre-placement of a suture through the pre-placed holes within the osteotomised rib. The pleura and intercostal musculature were closed, avoiding the intercostal neurovascular structures. The rib was re-apposed and the lateral approach was closed. The cases included were reviewed for both the rib pivoted as per the procedure required and postoperative complications. The study group comprised 8 Staffordshire Bull Terriers, 2 Poodles, 2 German Shepherd Dogs, 1 each of Basset Hound, Rhodesian Ridgeback, Golden Retriever, Australian Shepherd, Vizsla, Bull Mastiff, Schnauzer, Jack Russell Terrier, Bulldog, Deerhound, Labrador Retriever and Australian Terrier, and 1 cat. A modified rib pivot thoracotomy was performed for lung lobectomy (n = 11), oesophagectomy (7), subtotal pericardectomy (5), patent ductus arteriosus ligation (1) and thoracic duct ligation (1). Follow-up ranged from 2 to 40 weeks postoperatively. Postoperative complications included seroma formation in two dogs. A modified rib pivot thoracotomy should be considered as an alternative lateral thoracic approach with good exposure, minimal complications and low morbidity. © 2018 Australian Veterinary Association.

  8. Action of the isolated canine diaphragm on the lower ribs at high lung volumes.

    PubMed

    De Troyer, André; Wilson, Theodore A

    2014-10-15

    The normal diaphragm has an inspiratory action on the lower ribs, but subjects with chronic obstructive pulmonary disease commonly have an inward displacement of the lateral portions of the lower rib cage during inspiration. This paradoxical displacement, conventionally called 'Hoover's sign', has traditionally been attributed to the direct action of radially oriented diaphragmatic muscle fibres. In the present study, the inspiratory intercostal muscles in all interspaces in anaesthetized dogs were severed so that the diaphragm was the only muscle active during inspiration. The displacements of the lower ribs along the craniocaudal and laterolateral axes and the changes in pleural pressure (∆Ppl) and transdiaphragmatic pressure were measured during occluded breaths and mechanical ventilation at different lung volumes between functional residual capacity (FRC) and total lung capacity. From these data, the separate effects on rib displacement of ∆Ppl and of the force exerted by the diaphragm on the ribs were determined. Isolated spontaneous diaphragm contraction at FRC displaced the lower ribs cranially and outward, but this motion was progressively reversed into a caudal and inward motion as lung volume increased. However, although the force exerted by the diaphragm on the ribs decreased with increasing volume, it continued to displace the ribs cranially and outward. These observations suggest that Hoover's sign is usually caused by the decrease in the zone of apposition and, thus, by the dominant effect of ∆Ppl on the lower ribs, rather than an inward pull from the diaphragm. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  9. The Matrix Rib Plating System: improving aesthetic outcomes in microvascular breast reconstruction.

    PubMed

    Ahdoot, Michael A; Echo, Anthony; Otake, Leo R; Son, Ji; Zeidler, Kamakshi R; Saadian, Isaac; Lee, Gordon K

    2013-04-01

    During microvascular breast reconstruction, exposure of internal mammary vessels (IMVs) is facilitated by the removal of a portion of the rib resulting in occasional chest contour deformity (CCD). The use of rib plating may reduce CCD and reduce postoperative pain. All patients underwent microvascular breast reconstruction using IMVs. In the retrospective arm, photographs were assessed by a blinded reviewer for CCDs. In the prospective cohort, patients were randomized to rib plating with the Synthes Matrix Rib Plating System or no rib plating. Postoperatively, patients were assessed for CCD and pain. In the retrospective arm, 11 of 98 (11.2%) patients representing 12 of 130 (9.2%) breast reconstructions had a noticeable contour deformity. The average body mass index (BMI) of patients with CCDs was 26.6 kg/m. In the prospective arm, there was 16% (3 of 19) rate of visible and palpable CCDs among controls, compared to 0% rate of palpable and visible contour deformity in the rib plating group. Pain was decreased in the rib plating group on all postoperative days. The pain reduction was statistically significant at rest by postoperative day 30. The majority of patients (9 of 11) with compromised aesthetic outcomes had a BMI less than 30 kg/m, suggesting a paucity of overlying soft tissue contributed to visibility of these bony defects. Rib plating prevented chest contour deformity, reduced postoperative pain, and added limited additional morbidity. We believe that rib plating is a safe, useful adjunct to microvascular breast reconstruction using IMVs, as it may improve aesthetic outcomes and reduce postoperative pain.

  10. Pollen contamination in seed mixture increases the dominance of resistance to Bt maize in Spodoptera frugiperda (Lepidoptera: Noctuidae).

    PubMed

    Yang, Fei; Kerns, David L; Brown, Sebe; Head, Graham P; Huang, Fangneng

    2017-11-01

    Seed mixture, also called 'RIB', has been used to provide refuge populations for delaying insect resistance. Pollen contamination in RIB could result in refuge kernels of non-Bt maize expressing variable Bt proteins. Data are lacking regarding the impact of pollen contamination on evolution of resistance for ear-feeding insects. Here, we used Spodoptera frugiperda and Cry1F-maize as a model to examine if pollen contamination in RIB increases the dominance of insect resistance. Pollen contamination caused >66% refuge kernels in 5:95% (non-Bt:Bt) and 20:80% RIBs to express Cry1F protein. Survival at adult stage on pure non-Bt ears was similar (54.4-63.3%) among Cry1F-susceptible (SS), Cry1F-resistant (RR) and Cry1F-heterozygous (RS) S. frugiperda. On Bt ears, survival was similar between SS and RS (0.0-1.7%), but it was significantly less than that of RR (59.2%). On the two RIB refuge ears, survival at adult stage for RS (42.3% in 5:95% RIB; 50.0% in 20:80% RIB) was significantly higher than for SS (8.7% in 5:95% RIB; 10.0% in 20:80% RIB). The results suggest that pollen contamination in RIB could increase the dominance of resistance for ear-feeding insects by significantly reducing susceptible refuge populations and supporting higher survival of heterozygotes relative to homozygous susceptible insects. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  11. Digital radiography of crush thoracic trauma in the Sichuan earthquake

    PubMed Central

    Dong, Zhi-Hui; Shao, Heng; Chen, Tian-Wu; Chu, Zhi-Gang; Deng, Wen; Tang, Si-Shi; Chen, Jing; Yang, Zhi-Gang

    2011-01-01

    AIM: To investigate the features of crush thoracic trauma in Sichuan earthquake victims using chest digital radiography (CDR). METHODS: We retrospectively reviewed 772 CDR of 417 females and 355 males who had suffered crush thoracic trauma in the Sichuan earthquake. Patient age ranged from 0.5 to 103 years. CDR was performed between May 12, 2008 and June 7, 2008. We looked for injury to the thoracic cage, pulmonary parenchyma and the pleura. RESULTS: Antero-posterior (AP) and lateral CDR were obtained in 349 patients, the remaining 423 patients underwent only AP CDR. Thoracic cage fractures, pulmonary contusion and pleural injuries were noted in 331 (42.9%; 95% CI: 39.4%-46.4%), 67 and 135 patients, respectively. Of the 256 patients with rib fractures, the mean number of fractured ribs per patient was 3. Rib fractures were mostly distributed from the 3rd through to the 8th ribs and the vast majority involved posterior and lateral locations along the rib. Rib fractures had a significant positive association with non-rib thoracic fractures, pulmonary contusion and pleural injuries (P < 0.001). The number of rib fractures and pulmonary contusions were significant factors associated with patient death. CONCLUSION: Earthquake-related crush thoracic trauma has the potential for multiple fractures. The high number of fractured ribs and pulmonary contusions were significant factors which needed appropriate medical treatment. PMID:22132298

  12. Quality of life after major trauma with multiple rib fractures.

    PubMed

    Marasco, Silvana; Lee, Geraldine; Summerhayes, Robyn; Fitzgerald, Mark; Bailey, Michael

    2015-01-01

    Rib fractures are a common injury presenting to major trauma centres and community hospitals. Aside from the acute impact of rib fracture injury, longer-term morbidity of pain, disability and deformity have been described. Despite this, the mainstay of management for the vast majority of rib fracture injuries remains supportive only with analgesia and where required respiratory support. This study aimed to document the long-term quality of life in a cohort of major trauma patients with rib fracture injury over 24 months. Retrospective review (July 2006-July 2011) of 397 major trauma patients admitted to The Alfred Hospital with rib fractures and not treated with operative rib fixation. The main outcome measures were quality of life over 24 months post injury assessed using the Glasgow Outcome Scale Extended and SF12 health assessment forms and a pain questionnaire. Assessment over 24 months of major trauma patients with multiple rib fractures demonstrated significantly lower quality of life compared with published Australian norms at all time points measured. Return to work rates were poor with only 71% of those who were working prior to their accident, returning to any work. This study demonstrates a significant reduction in quality of life for rib fracture patients requiring admission to hospital, which does not return to the level of Australian norms for at least two years. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  13. 30 CFR 75.202 - Protection from falls of roof, face and ribs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Protection from falls of roof, face and ribs... Protection from falls of roof, face and ribs. (a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the...

  14. 30 CFR 75.202 - Protection from falls of roof, face and ribs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Protection from falls of roof, face and ribs... Protection from falls of roof, face and ribs. (a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the...

  15. 30 CFR 75.202 - Protection from falls of roof, face and ribs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Protection from falls of roof, face and ribs... Protection from falls of roof, face and ribs. (a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the...

  16. 30 CFR 75.202 - Protection from falls of roof, face and ribs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Protection from falls of roof, face and ribs... Protection from falls of roof, face and ribs. (a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the...

  17. 30 CFR 75.202 - Protection from falls of roof, face and ribs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection from falls of roof, face and ribs... Protection from falls of roof, face and ribs. (a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the...

  18. Comparison of Computed Tomography and Chest Radiography in the Detection of Rib Fractures in Abused Infants

    ERIC Educational Resources Information Center

    Wootton-Gorges, Sandra L.; Stein-Wexler, Rebecca; Walton, John W.; Rosas, Angela J.; Coulter, Kevin P.; Rogers, Kristen K.

    2008-01-01

    Purpose: Chest radiographs (CXR) are the standard method for evaluating rib fractures in abused infants. Computed tomography (CT) is a sensitive method to detect rib fractures. The purpose of this study was to compare CT and CXR in the evaluation of rib fractures in abused infants. Methods: This retrospective study included all 12 abused infants…

  19. Role of a polymorphism in a Hox/Pax-responsive enhancer in the evolution of the vertebrate spine

    USGS Publications Warehouse

    Guerreiro, Isabel; Nunes, Andreia; Woltering, Joost M.; Casaca, Ana; Nóvoa, Ana; Vinagre, Tânia; Hunter, Margaret E.; Duboule, Denis; Mallo, Moisés

    2013-01-01

    Patterning of the vertebrate skeleton requires the coordinated activity of Hox genes. In particular, Hox10 proteins are essential to set the transition from thoracic to lumbar vertebrae because of their rib-repressing activity. In snakes, however, the thoracic region extends well into Hox10-expressing areas of the embryo, suggesting that these proteins are unable to block rib formation. Here, we show that this is not a result of the loss of rib-repressing properties by the snake proteins, but rather to a single base pair change in a Hox/Paired box (Pax)-responsive enhancer, which prevents the binding of Hox proteins. This polymorphism is also found in Paenungulata, such as elephants and manatees, which have extended rib cages. In vivo, this modified enhancer failed to respond to Hox10 activity, supporting its role in the extension of rib cages. In contrast, the enhancer could still interact with Hoxb6 and Pax3 to promote rib formation. These results suggest that a polymorphism in the Hox/Pax-responsive enhancer may have played a role in the evolution of the vertebrate spine by differently modulating its response to rib-suppressing and rib-promoting Hox proteins.

  20. Design of a rib impactor equipment

    NASA Astrophysics Data System (ADS)

    Torres, C. R.; García, G.; Aguilar, L. A.; Martínez, L.

    2017-01-01

    The human ribs must be analyzed as long and as curved bones, due to their physiology. For the development of an experimental equipment that simulate the application of loads, over the rib in the moment of a frontal collision in an automobile with seat belt, it was applied a methodology that constituted in the identification of needs and the variables which led the design of 3D model, from this it was used the technique of fused deposition modeling for the development of the equipment pieces. The supports that hold the rib ends were design with two and three degrees of freedom that allows the simulation of rib movement with the spine and the breastbone in the breathing. For the simulation of the seat belt, it was determined to applied two loads over the front part of the rib from the sagittal and lateral plane respectively, for this it was made a displacement through a lineal actuator with a speed of 4mm/s. The outcomes shown a design of an equipment able to obtain the load parameters required to generate fractures in rib specimens. The equipment may be used for the study of specimens with nearby geometries to the rib taken as a reference.

  1. Research into topology optimization and the FDM method for a space cracked membrane

    NASA Astrophysics Data System (ADS)

    Hu, Qingxi; Li, Wanyuan; Zhang, Haiguang; Liu, Dali; Peng, Fujun; Duan, Yongchao

    2017-07-01

    The problem that the space membranes are easily torn open is the main focus in this paper, and a bionic strengthening-ribs structure is proposed for a space membrane based on interdisciplinary strengths, such as topology optimization, composite materials, and rapid prototyping. The optimization method and modeling method of membranes with bionic strengthening-ribs was studied. The PEEK and SCF/PEEK composite material which are applied to the space environment are chosen, and FDM technology is used. Through topology optimization, bionic strengthening-ribs with good tensile and tear capacities were obtained. Cracked membranes, cracked membranes with PEEK strengthening-ribs and SCF/PEEK strengthening-ribs were tested and test data were obtained. An extension situation and tension fracture were compared for three cases. The experimental results showed that membranes with the bionic strengthening-ribs structure have better mechanical properties, and the strength of the membranes with PEEK and SCF/PEEK strengthening-ribs were raised, respectively, up to 266.9% and 185.9%. The strengthening-ribs structure greatly improves the capacity to halt membrane crack-growth, which has an important significance to avoid membrane tear, and to ensure the spacecraft orbital lifetime.

  2. Proposal for an Accelerator R&D User Facility at Fermilab's Advanced Superconducting Test Accelerator (ASTA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Church, M.; Edwards, H.; Harms, E.

    2013-10-01

    Fermilab is the nation’s particle physics laboratory, supported by the DOE Office of High Energy Physics (OHEP). Fermilab is a world leader in accelerators, with a demonstrated track-record— spanning four decades—of excellence in accelerator science and technology. We describe the significant opportunity to complete, in a highly leveraged manner, a unique accelerator research facility that supports the broad strategic goals in accelerator science and technology within the OHEP. While the US accelerator-based HEP program is oriented toward the Intensity Frontier, which requires modern superconducting linear accelerators and advanced highintensity storage rings, there are no accelerator test facilities that support themore » accelerator science of the Intensity Frontier. Further, nearly all proposed future accelerators for Discovery Science will rely on superconducting radiofrequency (SRF) acceleration, yet there are no dedicated test facilities to study SRF capabilities for beam acceleration and manipulation in prototypic conditions. Finally, there are a wide range of experiments and research programs beyond particle physics that require the unique beam parameters that will only be available at Fermilab’s Advanced Superconducting Test Accelerator (ASTA). To address these needs we submit this proposal for an Accelerator R&D User Facility at ASTA. The ASTA program is based on the capability provided by an SRF linac (which provides electron beams from 50 MeV to nearly 1 GeV) and a small storage ring (with the ability to store either electrons or protons) to enable a broad range of beam-based experiments to study fundamental limitations to beam intensity and to develop transformative approaches to particle-beam generation, acceleration and manipulation which cannot be done elsewhere. It will also establish a unique resource for R&D towards Energy Frontier facilities and a test-bed for SRF accelerators and high brightness beam applications in support of the OHEP mission of Accelerator Stewardship.« less

  3. Rib fractures in trauma patients: does operative fixation improve outcome?

    PubMed

    Majak, Peter; Næss, Pål A

    2016-12-01

    Renewed interest in surgical fixation of rib fractures has emerged. However, conservative treatment is still preferred at most surgical departments. We wanted to evaluate whether operative treatment of rib fractures may benefit severely injured patients. Several studies report a reduction in mechanical ventilation time, ICU length of stay (LOS), hospital LOS, pneumonia, need for tracheostomy, pain and costs in operatively treated patients with multiple rib fractures compared with patients treated nonoperatively. Although patient selection and timing of the operation seem crucial for successful outcome, no consensus exists. Mortality reduction has only been shown in a few studies. Most studies are retrospective cohort and case-control studies. Only four randomized control trials exist. Conservative treatment, consisting of respiratory assistance and pain control, is still the treatment of choice in the vast majority of patients with multiple rib fractures. In selected patients, operative fixation of fractured ribs within 72 h postinjury may lead to better outcome. More randomized control trials are needed to further determine who benefits from surgical fixation of rib fractures.

  4. Alignment system for SGII-Up laser facility

    NASA Astrophysics Data System (ADS)

    Gao, Yanqi; Cui, Yong; Li, Hong; Gong, Lei; Lin, Qiang; Liu, Daizhong; Zhu, Baoqiang; Ma, Weixin; Zhu, Jian; Lin, Zunqi

    2018-03-01

    The SGII-Up laser facility in Shanghai is one of the most important high-power laser facilities in China. It is designed to obtain 24 kJ (3ω) of energy with a square pulse of 3 ns using eight laser beams (two bundles). To satisfy the requirements for the safety, efficiency, and quality, an alignment system is developed for this facility. This alignment system can perform automatic alignment of the preamplifier system, main amplifier system, and harmonic conversion system within 30 min before every shot during the routine operation of the facility. In this article, an overview of the alignment system is first presented. Then, its alignment characteristics are discussed, along with the alignment process. Finally, experimental results, including the alignment results and the facility performance, are reported. The results show that the far-field beam pointing alignment accuracy is better than 3 μrad, and the alignment error of the near-field beam centering is no larger than 1 mm. These satisfy the design requirements very well.

  5. Segmented beryllium target for a 2 MW super beam facility

    DOE PAGES

    Davenne, T.; Caretta, O.; Densham, C.; ...

    2015-09-14

    The Long Baseline Neutrino Facility (LBNF, formerly the Long Baseline Neutrino Experiment) is under design as a next generation neutrino oscillation experiment, with primary objectives to search for CP violation in the leptonic sector, to determine the neutrino mass hierarchy and to provide a precise measurement of θ 23. The facility will generate a neutrino beam at Fermilab by the interaction of a proton beam with a target material. At the ultimate anticipated proton beam power of 2.3 MW the target material must dissipate a heat load of between 10 and 25 kW depending on the target size. This paper presents amore » target concept based on an array of spheres and compares it to a cylindrical monolithic target such as that which currently operates at the T2K facility. Thus simulation results show that the proposed technology offers efficient cooling and lower stresses whilst delivering a neutrino production comparable with that of a conventional solid cylindrical target.« less

  6. Nozzle airfoil having movable nozzle ribs

    DOEpatents

    Yu, Yufeng Phillip; Itzel, Gary Michael

    2002-01-01

    A nozzle vane or airfoil structure is provided in which the nozzle ribs are connected to the side walls of the vane or airfoil in such a way that the ribs provide the requisite mechanical support between the concave side and convex side of the airfoil but are not locked in the radial direction of the assembly, longitudinally of the airfoil. The ribs may be bi-cast onto a preformed airfoil side wall structure or fastened to the airfoil by an interlocking slide connection and/or welding. By attaching the nozzle ribs to the nozzle airfoil metal in such a way that allows play longitudinally of the airfoil, the temperature difference induced radial thermal stresses at the nozzle airfoil/rib joint area are reduced while maintaining proper mechanical support of the nozzle side walls.

  7. Tapered rib fiber coupler for semiconductor optical devices

    DOEpatents

    Vawter, Gregory A.; Smith, Robert Edward

    2001-01-01

    A monolithic tapered rib waveguide for transformation of the spot size of light between a semiconductor optical device and an optical fiber or from the fiber into the optical device. The tapered rib waveguide is integrated into the guiding rib atop a cutoff mesa type semiconductor device such as an expanded mode optical modulator or and expanded mode laser. The tapered rib acts to force the guided light down into the mesa structure of the semiconductor optical device instead of being bound to the interface between the bottom of the guiding rib and the top of the cutoff mesa. The single mode light leaving or entering the output face of the mesa structure then can couple to the optical fiber at coupling losses of 1.0 dB or less.

  8. Opportunities for Materials Science and Biological Research at the OPAL Research Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, S. J.

    Neutron scattering techniques have evolved over more than 1/2 century into a powerful set of tools for determination of atomic and molecular structures. Modern facilities offer the possibility to determine complex structures over length scales from {approx}0.1 nm to {approx}500 nm. They can also provide information on atomic and molecular dynamics, on magnetic interactions and on the location and behaviour of hydrogen in a variety of materials. The OPAL Research Reactor is a 20 megawatt pool type reactor using low enriched uranium fuel, and cooled by water. OPAL is a multipurpose neutron factory with modern facilities for neutron beam research,more » radioisotope production and irradiation services. The neutron beam facility has been designed to compete with the best beam facilities in the world. After six years in construction, the reactor and neutron beam facilities are now being commissioned, and we will commence scientific experiments later this year. The presentation will include an outline of the strengths of neutron scattering and a description of the OPAL research reactor, with particular emphasis on it's scientific infrastructure. It will also provide an overview of the opportunities for research in materials science and biology that will be possible at OPAL, and mechanisms for accessing the facilities. The discussion will emphasize how researchers from around the world can utilize these exciting new facilities.« less

  9. Slipping rib syndrome: a place for sonography in the diagnosis of a frequently overlooked cause of abdominal or low thoracic pain.

    PubMed

    Meuwly, Jean-Yves; Wicky, Stephan; Schnyder, Pierre; Lepori, Domenico

    2002-03-01

    To describe the sonographic appearance of a poorly recognized cause of low thoracic or upper abdominal pain. Three sonographic descriptions of slipping rib syndrome are presented. The 3 patients had abnormal mobility of a cartilaginous rib, which could slip over an adjacent rib during abdominal muscle contraction. Slipping rib syndrome should be considered in patients with histories of upper abdominal or low thoracic pain of unknown origin. We suggest that high-resolution sonography of the costal margin should be added to abdominal sonography in cases of nonspecific abdominal pain.

  10. Rib fracture following stereotactic body radiotherapy: a potential pitfall.

    PubMed

    Stanic, Sinisa; Boike, Thomas P; Rule, William G; Timmerman, Robert D

    2011-11-01

    Although the incidence of rib fractures after conventional radiotherapy is generally low (<2%), rib fractures are a relatively common complication of stereotactic body radiotherapy. For malignancy adjacent to the chest wall, the incidence of rib fractures after stereotactic body radiotherapy is as high as 10%. Unrecognized bone fractures can mimic bone metastases on bone scintigraphy, can lead to extensive workup, and can even lead to consideration of unnecessary systemic chemotherapy, as treatment decisions can be based on imaging findings alone. Nuclear medicine physicians and diagnostic radiologists should always consider rib fracture in the differential diagnosis.

  11. Effect of rib angle on local heat/mass transfer distribution in a two-pass rib-roughened channel

    NASA Technical Reports Server (NTRS)

    Chandra, P. R.; Han, J. C.; Lau, S. C.

    1987-01-01

    The naphthalene sublimation technique is used to investigate the heat transfer characteristics of turbulent air flow in a two-pass channel. A test section that resembles the internal cooling passages of gas turbine airfoils is employed. The local Sherwood numbers on the ribbed walls were found to be 1.5-6.5 times those for a fully developed flow in a smooth square duct. Depending on the rib angle-of-attack and the Reynolds number, the average ribbed-wall Sherwood numbers were 2.5-3.5 times higher than the fully developed values.

  12. Cutoff-mesa isolated rib optical waveguide for III-V heterostructure photonic integrated circuits

    DOEpatents

    Vawter, Gregory A.; Smith, Robert E.

    1998-01-01

    A cutoff mesa rib waveguide provides single-mode performance regardless of any deep etches that might be used for electrical isolation between integrated electrooptic devices. Utilizing a principle of a cutoff slab waveguide with an asymmetrical refractive index profile, single mode operation is achievable with a wide range of rib widths and does not require demanding etch depth tolerances. This new waveguide design eliminates reflection effects, or self-interference, commonly seen when conventional rib waveguides are combined with deep isolation etches and thereby reduces high order mode propagation and crosstalk compared to the conventional rib waveguides.

  13. Cutoff-mesa isolated rib optical waveguide for III-V heterostructure photonic integrated circuits

    DOEpatents

    Vawter, G.A.; Smith, R.E.

    1998-04-28

    A cutoff mesa rib waveguide provides single-mode performance regardless of any deep etches that might be used for electrical isolation between integrated electrooptic devices. Utilizing a principle of a cutoff slab waveguide with an asymmetrical refractive index profile, single mode operation is achievable with a wide range of rib widths and does not require demanding etch depth tolerances. This new waveguide design eliminates reflection effects, or self-interference, commonly seen when conventional rib waveguides are combined with deep isolation etches and thereby reduces high order mode propagation and crosstalk compared to the conventional rib waveguides. 7 figs.

  14. Validation and Analysis of Numerical Results for a Two-Pass Trapezoidal Channel With Different Cooling Configurations of Trailing Edge.

    PubMed

    Siddique, Waseem; El-Gabry, Lamyaa; Shevchuk, Igor V; Fransson, Torsten H

    2013-01-01

    High inlet temperatures in a gas turbine lead to an increase in the thermal efficiency of the gas turbine. This results in the requirement of cooling of gas turbine blades/vanes. Internal cooling of the gas turbine blade/vanes with the help of two-pass channels is one of the effective methods to reduce the metal temperatures. In particular, the trailing edge of a turbine vane is a critical area, where effective cooling is required. The trailing edge can be modeled as a trapezoidal channel. This paper describes the numerical validation of the heat transfer and pressure drop in a trapezoidal channel with and without orthogonal ribs at the bottom surface. A new concept of ribbed trailing edge has been introduced in this paper which presents a numerical study of several trailing edge cooling configurations based on the placement of ribs at different walls. The baseline geometries are two-pass trapezoidal channels with and without orthogonal ribs at the bottom surface of the channel. Ribs induce secondary flow which results in enhancement of heat transfer; therefore, for enhancement of heat transfer at the trailing edge, ribs are placed at the trailing edge surface in three different configurations: first without ribs at the bottom surface, then ribs at the trailing edge surface in-line with the ribs at the bottom surface, and finally staggered ribs. Heat transfer and pressure drop is calculated at Reynolds number equal to 9400 for all configurations. Different turbulent models are used for the validation of the numerical results. For the smooth channel low-Re k-ɛ model, realizable k-ɛ model, the RNG k-ω model, low-Re k-ω model, and SST k-ω models are compared, whereas for ribbed channel, low-Re k-ɛ model and SST k-ω models are compared. The results show that the low-Re k-ɛ model, which predicts the heat transfer in outlet pass of the smooth channels with difference of +7%, underpredicts the heat transfer by -17% in case of ribbed channel compared to experimental data. Using the same turbulence model shows that the height of ribs used in the study is not suitable for inducing secondary flow. Also, the orthogonal rib does not strengthen the secondary flow rotational momentum. The comparison between the new designs for trailing edge shows that if pressure drop is acceptable, staggered arrangement is suitable for the outlet pass heat transfer. For the trailing edge wall, the thermal performance for the ribbed trailing edge only was found about 8% better than other configurations.

  15. Biomolecular identification of ancient Mycobacterium tuberculosis complex DNA in human remains from Britain and continental Europe.

    PubMed

    Müller, Romy; Roberts, Charlotte A; Brown, Terence A

    2014-02-01

    Tuberculosis is known to have afflicted humans throughout history and re-emerged towards the end of the 20th century, to an extent that it was declared a global emergency in 1993. The aim of this study was to apply a rigorous analytical regime to the detection of Mycobacterium tuberculosis complex (MTBC) DNA in 77 bone and tooth samples from 70 individuals from Britain and continental Europe, spanning the 1st-19th centuries AD. We performed the work in dedicated ancient DNA facilities designed to prevent all types of modern contamination, we checked the authenticity of all products obtained by the polymerase chain reaction, and we based our conclusions on up to four replicate experiments for each sample, some carried out in an independent laboratory. We identified 12 samples that, according to our strict criteria, gave definite evidence for the presence of MTBC DNA, and another 22 that we classified as "probable" or "possible." None of the definite samples came from vertebrae displaying lesions associated with TB. Instead, eight were from ribs displaying visceral new bone formation, one was a tooth from a skeleton with rib lesions, one was taken from a skeleton with endocranial lesions, one from an individual with lesions to the sacrum and sacroiliac joint and the last was from an individual with no lesions indicative of TB or possible TB. Our results add to information on the past temporal and geographical distribution of TB and affirm the suitability of ribs for studying ancient TB. Copyright © 2013 Wiley Periodicals, Inc.

  16. Scientific Opportunities and Plans for FRIB

    NASA Astrophysics Data System (ADS)

    Bollen, Georg

    2014-09-01

    FRIB, the US's ``Facility for Rare Isotope Beams'' under construction at Michigan State University will be a world-leading rare isotope beam facility. FRIB will be based on a 400 kW, 200 MeV/u heavy ion linac and provide a wide variety of high-quality beams of unstable isotopes at unprecedented intensities, opening exciting research perspectives with fast, stopped, and reaccelerated beams. This talk will summarize the scientific opportunities with FRIB in the areas of nuclear science, nuclear astrophysics, and the test of fundamental interaction and symmetries, as well using isotopes from FRIB for societal benefits. Design features of FRIB and the status of the ongoing construction will be presented. FRIB, the US's ``Facility for Rare Isotope Beams'' under construction at Michigan State University will be a world-leading rare isotope beam facility. FRIB will be based on a 400 kW, 200 MeV/u heavy ion linac and provide a wide variety of high-quality beams of unstable isotopes at unprecedented intensities, opening exciting research perspectives with fast, stopped, and reaccelerated beams. This talk will summarize the scientific opportunities with FRIB in the areas of nuclear science, nuclear astrophysics, and the test of fundamental interaction and symmetries, as well using isotopes from FRIB for societal benefits. Design features of FRIB and the status of the ongoing construction will be presented. This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC0000661, the State of Michigan and Michigan State University. Michigan State University designs and establishes FRIB as a DOE.

  17. Optical design of the National Ignition Facility main laser and switchyard/target area beam transport systems

    NASA Astrophysics Data System (ADS)

    Miller, John L.; English, R. Edward, Jr.; Korniski, Ronald J.; Rodgers, J. Michael

    1999-07-01

    The optical design of the main laser and transport mirror sections of the National Ignition Facility are described. For the main laser the configuration, layout constraints, multiple beam arrangement, pinhole layout and beam paths, clear aperture budget, ray trace models, alignment constraints, lens designs, wavefront performance, and pupil aberrations are discussed. For the transport mirror system the layout, alignment controls and clear aperture budget are described.

  18. The quality assessment of radial and tangential neutron radiography beamlines of TRR

    NASA Astrophysics Data System (ADS)

    Choopan Dastjerdi, M. H.; Movafeghi, A.; Khalafi, H.; Kasesaz, Y.

    2017-07-01

    To achieve a quality neutron radiographic image in a relatively short exposure time, the neutron radiography beam must be of good quality and relatively high neutron flux. Characterization of a neutron radiography beam, such as determination of the image quality and the neutron flux, is vital for producing quality radiographic images and also provides a means to compare the quality of different neutron radiography facilities. This paper provides a characterization of the radial and tangential neutron radiography beamlines at the Tehran research reactor. This work includes determination of the facilities category according to the American Society for Testing and Materials (ASTM) standards, and also uses the gold foils to determine the neutron beam flux. The radial neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. The tangential beam is a Category IV neutron radiography facility. Gold foil activation experiments show that the measured neutron flux for radial beamline with length-to-diameter ratio (L/D) =150 is 6.1× 106 n cm-2 s-1 and for tangential beamline with (L/D)=115 is 2.4× 104 n cm-2 s-1.

  19. Delayed pneumothorax complicating minor rib fracture after chest trauma.

    PubMed

    Lu, Ming-Shian; Huang, Yao-Kuang; Liu, Yun-Hen; Liu, Hui-Ping; Kao, Chiung-Lun

    2008-06-01

    Pneumothorax (PTX) after trauma is a preventable cause of death. Drainage procedures such as chest tube insertion have been traditionally advocated to prevent fatal tension PTX. We evaluated the safety of close observation in patients with delayed PTX complicating rib fracture after minor chest trauma. Adult patients (>18 years) with a diagnosis of chest trauma and 3 or fewer fractured ribs were reviewed. Case patients were divided according to age, location and number of fractured ribs, mechanism of trauma, and initial pulmonary complication after thoracic trauma for comparative analysis. There were 207 male (70.2%) and 88 female (29.8%) patients whose ages ranged from 18 to 93 years (median, 55 years). The mechanisms of trauma were a motor vehicle accident in 207 patients, falls in 66, pedestrian injury in 10, and assaults in 14. Ninety-five patients sustained 1 rib fracture, 95 had 2 rib fractures, and 105 suffered 3 rib fractures. Right-sided injury occurred in 164 cases, left-sided injury did in 127, and bilateral injury did in 4. The most frequent location of rib fractures was from the fourth rib to the ninth rib. The initial pulmonary complications after trauma were PTX in 16 patients, hemothorax in 43, pneumohemothorax in 14, lung contusion in 75, and isolated subcutaneous emphysema (SubcEmph) in 33. Thirty percent of the patients (n = 5/16) who presented with traumatic PTX were observed safely without drainage. Delayed PTX was recorded in 16 patients, occurring mostly during the first 2 days of their admission. Associated extrathoracic injury was recorded in 189 patients. The mean hospital stay of the patients was 7.66 days. Longer hospital stay was related to increasing number of fractured ribs, need for thoracic drainage, and the presence of associated extrathoracic injury. The mortality rate for the entire group was 2%. The presence of SubcEmph was the only risk factor associated with the development of delayed PTX. Patients sustaining blunt chest trauma and minor rib fractures should be admitted for close observation when presenting with SubcEmph because of possible delayed presentation of PTX.

  20. Analysis of cervical ribs in a series of human fetuses

    PubMed Central

    Bots, Jessica; Wijnaendts, Liliane C D; Delen, Sofie; Van Dongen, Stefan; Heikinheimo, Kristiina; Galis, Frietson

    2011-01-01

    In humans, an increasing body of evidence has linked the frequency of cervical ribs to stillbirths, other malformations and early childhood cancers. However, the frequency of cervical ribs in a putatively healthy fetal population is not sufficiently known to assess the actual medical risks of these prenatal findings. We therefore analyzed the presence of skeletal anomalies in a series of 199 electively aborted fetuses, which were whole-mount stained with alizarin red specific for skeletal tissues. Results show that approximately 40% of the fetuses had cervical ribs, even though external congenital abnormalities such as craniofacial and limb defects were absent. A literature overview indicates that the observed frequency of cervical ribs is comparable to results previously obtained for deceased fetuses with no or minor congenital anomalies, and higher than expected for healthy fetuses. This unexpected result can probably in part be explained by a higher detection rate of small cervical ribs when using alizarin red staining instead of radiographs. Additionally, studies in the literature suggest that the size of a cervical rib may indicate the severity of abnormalities, but this possibility requires further research. Anomalies of the axial skeleton are known to be caused by a disturbance of early development, which alters Hox gene expression, but in this study the origin of the stress could not be verified as maternal medical data were not available. The co-occurrence of rudimentary or absent 12th ribs in 23.6% of the cases with cervical ribs indicates that in approximately 8% of the fetuses a homeotic shift occurred over a larger part of the vertebral column. This suggests that the expression of multiple Hox genes may have been affected in these fetuses. Together, the high incidence of cervical ribs and also their co-occurrence with rudimentary or absent 12th ribs suggests that there may have been a disturbance of early development such that the studied fetuses are probably not informative about the general population. Future studies determining the frequency of cervical ribs in a more healthy fetal population are therefore needed to evaluate their potential as an indicator of medical risks. PMID:21689099

  1. Low evaluation rate for osteoporosis among patients presenting with a rib fracture.

    PubMed

    Kim, Whang; Gong, Hyun Sik; Lee, Seung Hoo; Park, Jin Woo; Kim, Kahyun; Baek, Goo Hyun

    2017-12-01

    This study in a regional hospital setting found a low evaluation rate for osteoporosis among patients presenting with a rib fracture. Increased emphasis or education for osteoporosis evaluation may be necessary in case of rib fractures. Rib fractures from a low-energy trauma are common in the elderly, and a history of rib fracture has been reported to increase the risk for a subsequent osteoporotic fracture. The purpose of this study was to evaluate how many of the patients presenting with an isolated rib fracture were being evaluated for osteoporosis and the risk for a subsequent fracture. We retrospectively reviewed all patients aged 50 years or older who were diagnosed with a rib fracture between January 2011 and April 2016 at a regional tertiary care university hospital near Seoul, South Korea. We excluded those who had been treated for osteoporosis or those with other concomitant fractures or fractures from a motor vehicle accident or cancer. We evaluated the frequency of dual energy X-ray absorptiometry (DXA) scan examinations in these patients. There were 231 patients with isolated rib fractures (132 men and 99 women). The mean age was 65 years. Rib fractures were most commonly diagnosed at the emergency department and most of the patients were referred to the department of thoracic surgery for follow-up evaluations. Of these 231 patients, 29 (12%) had DXA examinations after the injury, and only 9 (4%) of them did so within 6 months. Physicians specializing in orthopedic surgery, family medicine, internal medicine, rehabilitation medicine, and emergency medicine were ordering the examination. This study in a regional hospital setting found a low evaluation rate for osteoporosis among patients presenting with a rib fracture. This study suggests that increased emphasis or education for osteoporosis evaluation may be necessary for physicians who are often referred to for care of rib fractures.

  2. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors.

    PubMed

    Nambu, Atsushi; Onishi, Hiroshi; Aoki, Shinichi; Tominaga, Licht; Kuriyama, Kengo; Araya, Masayuki; Saito, Ryoh; Maehata, Yoshiyasu; Komiyama, Takafumi; Marino, Kan; Koshiishi, Tsuyota; Sawada, Eiichi; Araki, Tsutomu

    2013-02-07

    As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1-10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients.

  3. Traumatic Vertebral Fractures and Concomitant Fractures of the Rib in Southwest China, 2001 to 2010

    PubMed Central

    Wang, Hongwei; Zhou, Yue; Ou, Lan; Li, Changqing; Liu, Jun; Xiang, Liangbi

    2015-01-01

    Abstract To our knowledge, the clinical characteristics of traumatic vertebral fractures and concomitant fractures of the rib (TVF-RF) have not been described in previous studies. To investigate the clinical characteristics of patients managed for TVF-RF. A retrospective study of 3142 patients who presented with traumatic vertebral fractures was performed. Two hundred twenty-six patients (7.2%) suffered from TVF-RF. Incidence rate ratios were then calculated with respect to the level of injury to the spine, the ASIA classification of neurological deficits and age. There were 171 male (75.7%) and 55 female (24.3%) patients with a mean age of 43.8 years. The most common mechanisms were falls from high heights in 81 cases and road traffic crashes in 67 cases. Right-sided rib injury occurred in 106 cases, left-sided injury occurred in 76 cases, and bilateral injury occurred in 44 cases. The most frequent location of the rib fractures was from the fourth rib to the ninth rib (70.3%, 510/725). Initial pulmonary complications (IPC) after trauma occurred in 116 cases (51.3%). The mortality rate for the entire group was 1.3% (3/226). The patients with thoracic vertebral fractures and neurological deficits had a higher frequency of multiple rib fractures and IPC than the other patients (P < 0.05). With the increased number of rib fractures, the frequency of IPC and mean intensive care unit (ICU) length of stay also increased. The rates of complications for patients with rib fractures were significantly different from those without rib fractures. We should pay much attention to the patients who presented with thoracic vertebral fractures and neurological deficits for minimizing further complications and mortality in such patients who had a higher frequency of multiple rib fractures and IPC than the other patients. PMID:26554809

  4. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors

    PubMed Central

    2013-01-01

    Background As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Methods Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1–10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Results Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Conclusions Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients. PMID:23391264

  5. Use of a wire scanner for monitoring residual gas ionization in Soreq Applied Research Accelerator Facility 20 keV/u proton/deuteron low energy beam transport beam line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vainas, B.; Eliyahu, I.; Weissman, L.

    2012-02-15

    The ion source end of the Soreq Applied Research Accelerator Facility accelerator consists of a proton/deuteron ECR ion source and a low energy beam transport (LEBT) beam line. An observed reduction of the radio frequency quadrupole transmission with increase of the LEBT current prompted additional study of the LEBT beam properties. Numerous measurements have been made with the LEBT bream profiler wire biased by a variable voltage. Current-voltage characteristics in presence of the proton beam were measured even when the wire was far out of the beam. The current-voltage characteristic in this case strongly resembles an asymmetric diodelike characteristic, whichmore » is typical of Langmuir probes monitoring plasma. The measurement of biased wire currents, outside the beam, enables us to estimate the effective charge density in vacuum.« less

  6. NA61/SHINE facility at the CERN SPS: beams and detector system

    NASA Astrophysics Data System (ADS)

    Abgrall, N.; Andreeva, O.; Aduszkiewicz, A.; Ali, Y.; Anticic, T.; Antoniou, N.; Baatar, B.; Bay, F.; Blondel, A.; Blumer, J.; Bogomilov, M.; Bogusz, M.; Bravar, A.; Brzychczyk, J.; Bunyatov, S. A.; Christakoglou, P.; Cirkovic, M.; Czopowicz, T.; Davis, N.; Debieux, S.; Dembinski, H.; Diakonos, F.; Di Luise, S.; Dominik, W.; Drozhzhova, T.; Dumarchez, J.; Dynowski, K.; Engel, R.; Efthymiopoulos, I.; Ereditato, A.; Fabich, A.; Feofilov, G. A.; Fodor, Z.; Fulop, A.; Gaździcki, M.; Golubeva, M.; Grebieszkow, K.; Grzeszczuk, A.; Guber, F.; Haesler, A.; Hasegawa, T.; Hierholzer, M.; Idczak, R.; Igolkin, S.; Ivashkin, A.; Jokovic, D.; Kadija, K.; Kapoyannis, A.; Kaptur, E.; Kielczewska, D.; Kirejczyk, M.; Kisiel, J.; Kiss, T.; Kleinfelder, S.; Kobayashi, T.; Kolesnikov, V. I.; Kolev, D.; Kondratiev, V. P.; Korzenev, A.; Koversarski, P.; Kowalski, S.; Krasnoperov, A.; Kurepin, A.; Larsen, D.; Laszlo, A.; Lyubushkin, V. V.; Maćkowiak-Pawłowska, M.; Majka, Z.; Maksiak, B.; Malakhov, A. I.; Maletic, D.; Manglunki, D.; Manic, D.; Marchionni, A.; Marcinek, A.; Marin, V.; Marton, K.; Mathes, H.-J.; Matulewicz, T.; Matveev, V.; Melkumov, G. L.; Messina, M.; Mrówczyński, St.; Murphy, S.; Nakadaira, T.; Nirkko, M.; Nishikawa, K.; Palczewski, T.; Palla, G.; Panagiotou, A. D.; Paul, T.; Peryt, W.; Petukhov, O.; Pistillo, C.; Płaneta, R.; Pluta, J.; Popov, B. A.; Posiadala, M.; Puławski, S.; Puzovic, J.; Rauch, W.; Ravonel, M.; Redij, A.; Renfordt, R.; Richter-Was, E.; Robert, A.; Röhrich, D.; Rondio, E.; Rossi, B.; Roth, M.; Rubbia, A.; Rustamov, A.; Rybczyński, M.; Sadovsky, A.; Sakashita, K.; Savic, M.; Schmidt, K.; Sekiguchi, T.; Seyboth, P.; Sgalaberna, D.; Shibata, M.; Sipos, R.; Skrzypczak, E.; Słodkowski, M.; Sosin, Z.; Staszel, P.; Stefanek, G.; Stepaniak, J.; Stroebele, H.; Susa, T.; Szuba, M.; Tada, M.; Tereshchenko, V.; Tolyhi, T.; Tsenov, R.; Turko, L.; Ulrich, R.; Unger, M.; Vassiliou, M.; Veberic, D.; Vechernin, V. V.; Vesztergombi, G.; Vinogradov, L.; Wilczek, A.; Włodarczyk, Z.; Wojtaszek-Szwarz, A.; Wyszyński, O.; Zambelli, L.; Zipper, W.

    2014-06-01

    NA61/SHINE (SPS Heavy Ion and Neutrino Experiment) is a multi-purpose experimental facility to study hadron production in hadron-proton, hadron-nucleus and nucleus-nucleus collisions at the CERN Super Proton Synchrotron. It recorded the first physics data with hadron beams in 2009 and with ion beams (secondary 7Be beams) in 2011. NA61/SHINE has greatly profited from the long development of the CERN proton and ion sources and the accelerator chain as well as the H2 beamline of the CERN North Area. The latter has recently been modified to also serve as a fragment separator as needed to produce the Be beams for NA61/SHINE. Numerous components of the NA61/SHINE set-up were inherited from its predecessors, in particular, the last one, the NA49 experiment. Important new detectors and upgrades of the legacy equipment were introduced by the NA61/SHINE Collaboration. This paper describes the state of the NA61/SHINE facility — the beams and the detector system — before the CERN Long Shutdown I, which started in March 2013.

  7. Commissioning and initial operation of the Isotope Production Facility at the Los Alamos Neutron Science Center (LANSCE).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, K. F.; Alvestad, H. W.; Barkley, W. C.

    The recently completed 100-MeV H{sup +} Isotope Production Facility (IPF) at the LANSCE will provide radioisotopes for medical research and diagnosis, for basic research and for commercial use. A change to the LANSCE accelerator facility allowed for the installation of the IPF. Three components make up the LANSCE accelerator: an injector that accelerates the H{sup +} beam to 750-KeV, a drift-tube linac (DTL) that increases the beam energy to 100-MeV, and a side-coupled cavity linac (SCCL) that accelerates the beam to 800-MeV. The transition region, a space between the DTL and the SCCL, was modified to permit the insertion ofmore » a kicker magnet (23{sup o} kick angle) for the purpose of extracting a portion of the 100-MeV H{sup +} beam. A new beam line was installed to transport the extracted H{sup +} beam to the radioisotope production target chamber. This paper will describe the commissioning and initial operating experiences of IPF.« less

  8. A new ion beam facility based on a 3 MV Tandetron™ at IFIN-HH, Romania

    NASA Astrophysics Data System (ADS)

    Burducea, I.; Straticiuc, M.; Ghiță, D. G.; Moșu, D. V.; Călinescu, C. I.; Podaru, N. C.; Mous, D. J. W.; Ursu, I.; Zamfir, N. V.

    2015-09-01

    A 3 MV Tandetron™ accelerator system has been installed and commissioned at the "Horia Hulubei" National Institute for Physics and Nuclear Engineering - IFIN-HH, Măgurele, Romania. The main purpose of this machine is to strengthen applied nuclear physics research ongoing in our institute for more than four decades. The accelerator system was developed by High Voltage Engineering Europa B.V. (HVE) and comprises three high energy beam lines. The first beam line is dedicated to ion beam analysis (IBA) techniques: Rutherford Backscattering Spectrometry - RBS, Nuclear Reaction Analysis - NRA, Particle Induced X-ray and γ-ray Emission - PIXE and PIGE and micro-beam experiments - μ-PIXE. The second beam line is dedicated to high energy ion implantation experiments and the third beam line was designed mainly for nuclear cross-sections measurements used in nuclear astrophysics. A unique feature, the first time in operation at an accelerator facility is the Na charge exchange canal (CEC), which is used to obtain high intensity beams of He- of at least 3 μA. The results of the acceptance tests demonstrate the huge potential of this new facility in various fields, from IBA to radiation hardness studies and from medical or environmental applications to astrophysics. The main features of the accelerator are presented in this paper.

  9. Patient handling system for carbon ion beam scanning therapy

    PubMed Central

    Shirai, Toshiyuki; Takei, Yuka; Furukawa, Takuji; Inaniwa, Taku; Matsuzaki, Yuka; Kumagai, Motoki; Murakami, Takeshi; Noda, Koji

    2012-01-01

    Our institution established a new treatment facility for carbon ion beam scanning therapy in 2010. The major advantages of scanning beam treatment compared to the passive beam treatment are the following: high dose conformation with less excessive dose to the normal tissues, no bolus compensator and patient collimator/ multi‐leaf collimator, better dose efficiency by reducing the number of scatters. The new facility was designed to solve several problems encountered in the existing facility, at which several thousand patients were treated over more than 15 years. Here, we introduce the patient handling system in the new treatment facility. The new facility incorporates three main systems, a scanning irradiation system (S‐IR), treatment planning system (TPS), and patient handling system (PTH). The PTH covers a wide range of functions including imaging, geometrical/position accuracy including motion management (immobilization, robotic arm treatment bed), layout of the treatment room, treatment workflow, software, and others. The first clinical trials without respiratory gating have been successfully started. The PTH allows a reduction in patient stay in the treatment room to as few as 7 min. The PTH plays an important role in carbon ion beam scanning therapy at the new institution, particularly in the management of patient handling, application of image‐guided therapy, and improvement of treatment workflow, and thereby allows substantially better treatment at minimum cost. PACS numbers: 87.56.‐v; 87.57.‐s; 87.55.‐x PMID:23149784

  10. Sex determination based on a thoracic vertebra and ribs evaluation using clinical chest radiography.

    PubMed

    Tsubaki, Shun; Morishita, Junji; Usumoto, Yosuke; Sakaguchi, Kyoko; Matsunobu, Yusuke; Kawazoe, Yusuke; Okumura, Miki; Ikeda, Noriaki

    2017-07-01

    Our aim was to investigate whether sex can be determined from a combination of geometric features obtained from the 10th thoracic vertebra, 6th rib, and 7th rib. Six hundred chest radiographs (300 males and 300 females) were randomly selected to include patients of six age groups (20s, 30s, 40s, 50s, 60s, and 70s). Each group included 100 images (50 males and 50 females). A total of 14 features, including 7 lengths, 5 indices for the vertebra, and 2 types of widths for ribs, were utilized and analyzed for sex determination. Dominant features contributing to sex determination were selected by stepwise discriminant analysis after checking the variance inflation factors for multicollinearity. The accuracy of sex determination using a combination of the vertebra and ribs was evaluated from the selected features by the stepwise discriminant analysis. The accuracies in each age group were also evaluated in this study. The accuracy of sex determination based on a combination of features of the vertebra and ribs was 88.8% (533/600). This performance was superior to that of the vertebra or ribs only. Moreover, sex determination of subjects in their 20s demonstrated the highest accuracy (96.0%, 96/100). The features selected in the stepwise discriminant analysis included some features in both the vertebra and ribs. These results indicate the usefulness of combined information obtained from the vertebra and ribs for sex determination. We conclude that a combination of geometric characteristics obtained from the vertebra and ribs could be useful for determining sex. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Internal rib structure can be predicted using mathematical models: An anatomic study comparing the chest to a shell dome with application to understanding fractures.

    PubMed

    Casha, Aaron R; Camilleri, Liberato; Manché, Alexander; Gatt, Ruben; Attard, Daphne; Gauci, Marilyn; Camilleri-Podesta, Marie-Therese; Mcdonald, Stuart; Grima, Joseph N

    2015-11-01

    The human rib cage resembles a masonry dome in shape. Masonry domes have a particular construction that mimics stress distribution. Rib cortical thickness and bone density were analyzed to determine whether the morphology of the rib cage is sufficiently similar to a shell dome for internal rib structure to be predicted mathematically. A finite element analysis (FEA) simulation was used to measure stresses on the internal and external surfaces of a chest-shaped dome. Inner and outer rib cortical thickness and bone density were measured in the mid-axillary lines of seven cadaveric rib cages using computerized tomography scanning. Paired t tests and Pearson correlation were used to relate cortical thickness and bone density to stress. FEA modeling showed that the stress was 82% higher on the internal than the external surface, with a gradual decrease in internal and external wall stresses from the base to the apex. The inner cortex was more radio-dense, P < 0.001, and thicker, P < 0.001, than the outer cortex. Inner cortical thickness was related to internal stress, r = 0.94, P < 0.001, inner cortical bone density to internal stress, r = 0.87, P = 0.003, and outer cortical thickness to external stress, r = 0.65, P = 0.035. Mathematical models were developed relating internal and external cortical thicknesses and bone densities to rib level. The internal anatomical features of ribs, including the inner and outer cortical thicknesses and bone densities, are similar to the stress distribution in dome-shaped structures modeled using FEA computer simulations of a thick-walled dome pressure vessel. Fixation of rib fractures should include the stronger internal cortex. © 2015 Wiley Periodicals, Inc.

  12. When Should Abdominal Computed Tomography Be Considered in Patients with Lower Rib Fractures?

    PubMed

    Jeroukhimov, Igor; Hershkovitz, Yehuda; Wiser, Itay; Kessel, Boris; Ayyad, Mohammed; Gatot, Inbar; Shapira, Zahar; Jeoravlev, Svetlana; Halevy, Ariel; Lavy, Ron

    2017-05-01

    Lower rib fractures are considered as a marker of intra-abdominal organ injury. Abdominal computed tomography (CT) is the "gold standard" examination for patients with lower rib fractures. However, the reported incidence of concomitant intra-abdominal injuries (IAI) is 20%-40%. The purpose of this study was to evaluate the incidence of intra-abdominal organ injuries in blunt trauma patients with lower rib fractures. Medical charts and radiology reports of patients with lower rib (from the 8th to 12th rib) fractures admitted to our center during a 6-year period were retrospectively reviewed. Patients were divided into two groups. Group I included patients with intra-abdominal injury (IAI) diagnosed either by CT or on urgent laparotomy, and Group II included those with normal abdominal CT scans. Data included demographics, mechanism of injury, laboratory tests, radiology results including number and location of fractured ribs, and incidence of IAI. Overall 318 patients were included in the study. Fifty-seven patients (17.9%) had 71 IAIs compared with 265 (82.1%) patients with no IAI. Logistic regression identified age younger than 55 years (relative risk [RR] = 7.2; 95% confidence interval [CI] 3.1-16.8; p = 0.001), bilateral rib fractures (RR = 3.9; 95% CI 1.1-13.5; p = 0.03) and decreased levels of hematocrit (RR = 2.4; 95% CI 1.2-4.8; p = 0.016) as independent risk factors for the presence of IAI. Abdominal CT should be considered in blunt trauma patients with lower rib fractures who are younger than 55 years of age and have bilateral rib fractures and decreased levels of hematocrit on admission. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Clinical Utility of Chest Computed Tomography in Patients with Rib Fractures CT Chest and Rib Fractures.

    PubMed

    Chapman, Brandon C; Overbey, Douglas M; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T; French, Andrew; Johnson, Jeffrey L; Burlew, Clay C; Barnett, Carlton; Moore, Ernest E; Pieracci, Fredric M

    2016-12-01

    Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Retrospective cohort study of blunt trauma patients with rib fractures at a level I trauma center that had both a CXR and a CT chest. The CT finding of ≥ 3 additional fractures in patients with ≤ 3 rib fractures on CXR was considered clinically meaningful. Student's t-test and chi-square analysis were used for comparison. We identified 499 patients with rib fractures: 93 (18.6%) had CXR only, 7 (1.4%) had chest CT only, and 399 (79.9%) had both CXR and chest CT. Among these 399 patients, a total of 1,969 rib fractures were identified: 1,467 (74.5%) were missed by CXR. The median number of additional fractures identified by CT was 3 (range, 4 - 15). Of 212 (53.1%) patients with a clinically meaningful increase in the number of fractures, 68 patients underwent one or more clinical interventions: 36 SICU admissions, 20 pain catheter placements, 23 epidural placements, and 3 SSRF. Additionally, 70 patients had a chest tube placed for retained hemothorax or occult pneumothorax. Overall, 138 patients (34.5%) had a change in clinical management based upon CT chest. The chest X-ray missed ~75% of rib fractures seen on chest CT. Although patients with a clinical meaningful increase in the number of rib fractures were more likely to be admitted to the intensive care unit, there was no associated improvement in pulmonary outcomes.

  14. Sex estimation from measurements of the first rib in a contemporary Polish population.

    PubMed

    Kubicka, Anna Maria; Piontek, Janusz

    2016-01-01

    The aim of this study was to evaluate the accuracy of sex assessment using measurements of the first rib from computed tomography (CT) to develop a discriminant formula. Four discriminant formulae were derived based on CT imaging of the right first rib of 85 female and 91 male Polish patients of known age and sex. In direct discriminant analysis, the first equation consisted of all first rib variables; the second included measurements of the rib body; the third comprised only two measurements of the sternal end of the first rib. The stepwise method selected the four best variables from all measurements. The discriminant function equation was then tested on a cross-validated group consisting of 23 females and 24 males. The direct discriminant analysis showed that sex assessment was possible in 81.5% of cases in the first group and in 91.5% in the cross-validated group when all variables for the first rib were included. The average accuracy for the original group for rib body and sternal end was 80.9 and 67.9%, respectively. The percentages of correctly assigned individuals for the functions based on the rib body and sternal end in the cross-validated group were 76.6 and 85.0%, respectively. Higher average accuracies were obtained for stepwise discriminant analysis: 83.1% for the original group and 91.2% for the cross-validated group. The exterior edge, anterior-posterior of the sternal end, and depth of the arc were the most reliable parameters. Our results suggest that the first rib is dimorphic and that the described method can be used for sex assessment.

  15. Ribbed electrode substrates

    DOEpatents

    Breault, Richard D.; Goller, Glen J.

    1983-01-01

    A ribbed substrate for an electrochemical cell electrode is made from a mixture of carbon fibers and carbonizable resin and has a mean pore size in the ribs which is 60-75% of the mean pore size of the web portions of the substrate which interconnect the ribs. Preferably the mean pore size of the web portion is 25-45 microns; and, if the substrate includes edge seals parallel to the ribs, the edge seals preferably have a mean pore size no greater than about ten microns. Most preferably the substrate has the same ratio of carbon fibers to polymeric carbon in all areas, including the ribs, webs, and edge seals. A substrate according to the present invention will have better overall performance than prior art substrates and minimizes the substrate thickness required for the substrate to perform all its functions well.

  16. Cerebro-costo-mandibular syndrome: prognosis and proposal for classification.

    PubMed

    Nagasawa, Hiroyuki; Yamamoto, Yutaka; Kohno, Yoshinori

    2010-09-01

    Cerebro-costo-mandibular syndrome (CCMS) is a very rare syndrome characterized by micrognathia and posterior rib gap, with a poor prognosis. To date, only 75 cases have been reported worldwide. The overall survival rate for patients with this disorder has not been reported, and a classification of the patients on the basis of the prognosis is not yet available. The present study analyzed the figures and prognoses of past patients and documented a new case of CCMS. Formerly published case reports and personal communications were used to reveal the prognosis and classification of CCMS. The occurrence ratios of rib gap defects and of missing ribs were examined. Patients were divided into the following three groups according to their life span: lethal type, where the patients died before 1 month; severe type, where the patients lived for 1-12 months; and mild type, where they survived for more than 1 year. A comparison was made of the number of rib gaps, missing ribs, and the rib gap ratio (defined as the number of rib gaps divided by the number of all existing ribs) among these three groups. A significant difference in the number of rib defects between the lethal type and other types was noted. Short life span of severe type patients, compared to mild type, was attributed to their subjection to severe respiratory infection. CCMS can be classified into three categories--lethal, severe, and mild--according to the severity of the symptoms and prognosis.

  17. The mechanoreceptors of the costo-vertebral joints

    PubMed Central

    Godwin-Austen, R. B.

    1969-01-01

    1. Unitary recording in the thoracic dorsal roots of mechanoreceptor discharges from the costo-vertebral joints was carried out in the cat and rabbit. Criteria for the identification of costo-vertebral joint mechanoreceptors were established. 2. The majority of rib joint mechanoreceptors are slowly adapting and fifty-three such receptors were studied. Five rapidly adapting receptors were also identified. 3. The responses of these receptors have been correlated with rib position and movement. The slowly adapting receptors gave a monotonic response to different rib positions. 72% showed an increase of discharge rate with displacements towards expiratory rib positions. 4. In response to manually imposed rib movements slowly adapting joint mechanoreceptors gave a dynamic response which was directly related to the velocity of the movement and adapted within 2 sec. The movements of breathing produced a corresponding alteration of the discharge frequency of the slowly adapting receptors. 5. Slowly adapting receptors were localized to the capsule of the costo-transverse joint by probing. They responded to increased intra-articular pressure with an increase of discharge rate and were silenced by intra-articular lignocaine, 0·4%. 6. Rapidly adapting joint mechanoreceptors responded to rib movement with a brief burst of discharges. 7. The rib joint mechanoreceptors signal rib joint position, and the direction and velocity of rib movement. It is suggested that these afferent discharges provide the basis for the perception of respiratory movements of the chest. The significance of these receptors to the `sense of effort' resulting from a resistance to breathing is discussed. PMID:5789947

  18. Improving mechanical properties of maxillary complete dentures through a bioinspired engineering design.

    PubMed

    White, James A P; Bond, Ian P; Jagger, Daryll C

    2011-01-01

    This study investigated how ribbed design features, including palatal rugae, may be used to significantly improve the structural performance of a maxillary denture under load. A computer-aided design model of a generic maxillary denture, incorporating various rib features, was created and imported into a finite element analysis program. The denture and ribbed features were assigned the material properties of standard denture acrylic resin, and load was applied in two different ways: the first simulating a three-point flexural bend of the posterior section and the second simulating loading of the entire palatal region. To investigate the combined use of ribbing and reinforcement, the same simulations were repeated with the ribbed features having a Young modulus two orders of magnitude greater than denture acrylic resin. For a prescribed load, total displacements of tracking nodes were compared to those of a control denture (without ribbing) to assess relative denture rigidity. When subjected to flexural loading, an increase in rib depth was seen to result in a reduction of both the transverse displacement of the last molar and vertical displacement at the centerline. However, ribbed features assigned the material properties of denture acrylic resin require a depth that may impose on speech and bolus propulsion before significant improvements are observed. The use of ribbed features, when made from a significantly stiffer material (eg, fiber-reinforced polymer) and designed to mimic palatal rugae, offer an acceptable method of providing significant improvements in rigidity to a maxillary denture under flexural load.

  19. A Novel Hybrid Ultramicrotomy/FIB-SEM Technique: Preparation of Serial Electron-Transparent Thin Sections of a Hayabusa Grain

    NASA Technical Reports Server (NTRS)

    Berger, Eve L.; Keller, Lindsay P.

    2014-01-01

    The Japanese space agency's (JAXA) Hayabusa mission returned the first particulate samples (typically <100micron) from the surface of an asteroid (25143 Itokawa). These precious samples provide important insights into early Solar System processes, but their sizes pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on sample preparation. We developed a hybrid technique combining traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for more thorough in situ investigations of grain surfaces and interiors. Using this method, we increase the number of FIB-prepared sections that can be recovered from a particle with dimensions on the order of tens of microns. These sections can be subsequently analyzed using a variety of analytical techniques. Particle RA-QD02-0211 is a approx. 40×40×20 micron particle from Itokawa containing olivine and Fe sulfides. It was embedded in low viscosity epoxy and partly sectioned to a depth of approx 10 micron; sections are placed on Cu grids with thin amorphous films for transmission electron microscope (TEM) analyses. With the sample surface partly exposed, the epoxy bullet is trimmed to a height of approx. 5mm to accommodate the allowable dimensions for FIB work (FEI Quanta 600 3D dual beam FIB-SEM). Using a diamond trim knife, the epoxy surrounding the grain is removed on 3 sides (to within a few microns of the grain); the depth of material removed extends well below the bottom of the particle. The sample is attached to an SEM pin mount, the epoxy coated with conductive paint, and the entire assembly coated with approx. 40nm of carbon to eliminate sample charging during FIB work. A protective carbon cap is placed according to the plan for the 15 FIB sections. The central 'spine' of the cap runs perpendicular to the front of the sample, and the 'ribs' protruding from either side run parallel. Each rib indicates the location of a planned FIB section, and the spine contains the final two planned sections. We use a cap with a 4 micron-wide spine and 2micron-wide ribs that have ?3.5 micron of space between them (narrower cuts result in too much re-deposition of material inside the trenches). Using a 30kV, 3nA ion-beam we expose the front surface of the grain and commence milling trenches between sections. Rather than using the typical C-cut to prepare the sample for lift-out, an L-cut is used instead, leaving the sample connected by an interior tab. tab. Sections are lifted out, attached to TEM grids and thinned to electron transparency. TEM analyses show that our hybrid technique preserves both interior and edge features, including surface modifications from exposure to the space environment, such as damaged rims that form in response to solar wind implantation effects and adhering grains. In addition, the FIB sections provide larger areas that are free of fractures and chatter effects in comparison to the microtome thin sections, thus enabling more accurate measurements of solar flare particle track densities that are used to determine the surface exposure age of the particles.

  20. Toward a fourth-generation x-ray source.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monction, D. E.

    1999-05-19

    The field of synchrotron radiation research has grown rapidly over the last 25 years due to both the push of the accelerator and magnet technology that produces the x-ray beams and the pull of the extraordinary scientific research that is possible with them. Three successive generations of synchrotrons radiation facilities have resulted in beam brilliances 11 to 12 orders of magnitude greater than the standard laboratory x-ray tube. However, greater advances can be easily imagined given the fact that x-ray beams from present-day facilities do not exhibit the coherence or time structure so familiar with the optical laser. Theoretical workmore » over the last ten years or so has pointed to the possibility of generating hard x-ray beams with laser-like characteristics. The concept is based on self-amplified spontaneous emission (SASE) in flee-electron lasers. A major facility of this type based upon a superconducting linac could produce a cost-effective facility that spans wave-lengths from the ultraviolet to the hard x-ray regime, simultaneously servicing large numbers experimenters from a wide range of disciplines. As with each past generation of synchrotrons facilities, immense new scientific opportunities would result from fourth-generation sources.« less

  1. Design study of beam transport lines for BioLEIR facility at CERN

    NASA Astrophysics Data System (ADS)

    Ghithan, S.; Roy, G.; Schuh, S.

    2017-09-01

    The biomedical community has asked CERN to investigate the possibility to transform the Low Energy Ion Ring (LEIR) accelerator into a multidisciplinary, biomedical research facility (BioLEIR) that could provide ample, high-quality beams of a range of light ions suitable for clinically oriented, fundamental research on cell cultures and for radiation instrumentation development. The present LEIR machine uses fast beam extraction to the next accelerator in the chain, eventually leading to the Large Hadron Collider (LHC) . To provide beam for a biomedical research facility, a new slow extraction system must be installed. Two horizontal and one vertical experimental beamlines were designed for transporting the extracted beam to three experimental end-stations. The vertical beamline (pencil beam) was designed for a maximum energy of 75 MeV/u for low-energy radiobiological research, while the two horizontal beamlines could deliver up to 440 MeV/u. One horizontal beamline shall be used preferentially for biomedical experiments and shall provide pencil beam and a homogeneous broad beam, covering an area of 5 × 5 cm2 with a beam homogeneity of ±5%. The second horizontal beamline will have pencil beam only and is intended for hardware developments in the fields of (micro-)dosimetry and detector development. The minimum full aperture of the beamlines is approximately 100 mm at all magnetic elements, to accommodate the expected beam envelopes. Seven dipoles and twenty quadrupoles are needed for a total of 65 m of beamlines to provide the specified beams. In this paper we present the optical design for the three beamlines.

  2. Focusing through the rib cage for MR-guided transcostal FUS

    NASA Astrophysics Data System (ADS)

    Gao, J.; Volovick, A.; Pekelny, Y.; Huang, ZH.; Cochran, S.; Melzer, A.

    2012-10-01

    The rib cage presents a significant obstacle in transcostal focused ultrasound surgery (FUS). This paper proposes a geometric solution, based on central projection from the focus to identify transducer elements affected by ribs shadowing which should be switched off. Its effectiveness in phantom experiments and simulations is reported, and ways are discussed to further reduce energy deposition on the ribs while enhancing heating at the focus. A tissue-mimicking phantom with phantom of ribs was sonicated using a 208-element 1.15 MHz bowl transducer and a 1000-element 550 kHz planar matrix transducer (both ExAblate, InSightec, Israel). The temperature evolution was monitored with real-time MRI thermometry (GE, USA). Numerical simulations were performed with FEA software (PZFlex, Weidlinger Associates, USA) to investigate different skin-focus and transducer-rib distances. The temperature rise near the ribs was reduced to 16°C and 4°C for the 1.15 MHz and 550 kHz transducers respectively. With the 1.15 MHz transducer, the focal temperature reached the ablation threshold. These measurements are in good agreement with simulations. The proposed method shows promising results for transcostal FUS. Residual temperature rise on the ribs can be further reduced by active cooling, allowing the higher energies essential for efficient ablation.

  3. [Analysis of 163 rib fractures by imaging examination].

    PubMed

    Song, Tian-fu; Wang, Chao-chao

    2014-12-01

    To explore the applications of imaging examination on rib fracture sites in forensic identification. Features including the sites, numbers of the processed imaging examination and the first radiological technology at diagnosis in 56 cases of rib fractures from 163 injuries were retrospectively analyzed. The detection rate of the rib fractures within 14 days was 65.6%. The initial detection rate of anterior rib fracture proceeded by X-ray was 76.2%, then 90.5% detected at a second time X-ray, while the detection rate of CT was 66.7% and 80.0%, respectively. The initial detec- tion rate of rib fracture in axillary section proceeded by X-ray was 27.6%, then 58.6% detected at a second time X-ray, while the detection rate of CT was 54.3% and 80.4%, respectively. The initial detection rate of posterior rib fracture proceeded by X-ray was 63.6%, then 81.8% detected at a second time X-ray, while the detection rate of CT was 50.0% and 70.0%, respectively. It is important to pay attention to the use of combined imaging examinations and the follow-up results. In the cases of suspicious for rib fracture in axillary section, CT examination is suggested in such false X-ray negative cases.

  4. Concurrent rib and pelvic fractures as an indicator of solid abdominal organ injury.

    PubMed

    Al-Hassani, Ammar; Afifi, Ibrahim; Abdelrahman, Husham; El-Menyar, Ayman; Almadani, Ammar; Recicar, Jan; Al-Thani, Hassan; Maull, Kimball; Latifi, Rifat

    2013-01-01

    To study the association of solid organ injuries (SOIs) in patients with concurrent rib and pelvic fractures. Retrospective analysis of prospectively collected data from November 2007 to May 2010. Patients' demographics, mechanism of injury, Injury severity scoring, pelvic fracture, and SOIs were analyzed. Patients with SOIs were compared in rib fractures with and without pelvic fracture. The study included 829 patients (460 with rib fractures ± pelvic fracture and 369 with pelvic fracture alone) with mean age of 35 ± 12.7 years. Motor vehicle crashes (45%) and falls from height (30%) were the most common mechanism of injury. The overall incidence of SOIs in this study was 22% (185/829). Further, 15% of patient with rib fractures had associated pelvic fracture. SOI was predominant in patients with concurrent rib fracture and pelvic fracture compared to ribs or pelvic fractures alone (42% vs. 26% vs. 15%, respectively, p = 0.02). Concurrent multiple rib fractures and pelvic fracture increases the risk of SOI compared to either group alone. Lower RFs and pelvic fracture had higher association for SOI and could be used as an early indicator of the presence of SOIs. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  5. [Surgical fixation of rib fractures with clips and titanium bars (STRATOS System). Preliminary experience].

    PubMed

    Moreno De La Santa Barajas, Pablo; Polo Otero, María Dolores; Delgado Sánchez-Gracián, Carlos; Lozano Gómez, Manuel; Toscano Novella, Alberto; Calatayud Moscoso Del Prado, Julia; Leal Ruiloba, Sonsoles; Choren Durán, Maria L

    2010-09-01

    Rib fractures are very common in closed chest injuries. The majority of these patients suffer significant pain with movement and cough. The purpose of this study is to assess the usefulness of titanium rib bars and clips in stabilising rib fractures. Twenty-two patients with rib fractures were treated with open reduction and internal fixation between 2008 and 2009. Indications for treatment were defined as; 1) Patients with unstable chest (13 patients), 2) Patients with pain or instability due to rib fractures (6 patients), and 3) Significant traumatic deformities of the chest wall (3 patients). Age, traumatic mechanism, chest and associated injuries, surgical data, complications and follow-up were prospectively analysed. The surgical technique is described. The majority of patients were extubated immediately after surgery. All patients with pain or instability showed a subjective improvement or disappearance of pain after the surgery. Four patients had a wound infection which had to be drained. After 3 months, 55% of the patients had returned to work or normal life. The results in each group are described. Open reduction with internal fixation of rib fractures is a good alternative. The use of titanium rib bars and clips give good clinical results, are easy to apply and have few complications. Copyright © 2010 AEC. Published by Elsevier Espana. All rights reserved.

  6. Improved oil-off survivability of tapered roller bearings

    NASA Technical Reports Server (NTRS)

    Kreider, Gary E.; Lee, Peter W.

    1987-01-01

    The aim of this program is to improve the oil-off survivability of a tapered roller bearing when applied to a helicopter transmission, since the tapered bearing has shown a performance advantage in this application. However, the critical roller end-rib conjunction is vulnerable to damage in an oil-off condition. Three powdered metal materials were selected to use as the rib material for oil-off evaluation. These were: M2 steel to a 65% density, CBS 1000M 65% density, and CBS 1000M 75% density. The bearing styles tested were ribbed cone (inner race) and ribbed cup (outer race). Carburized solid CBS 600 was also used as a ribbed material for comparison of oil-off results. The tests were conducted at six speeds from 4000 rpm (0.26 million DN) through 37000 rpm (2.4 million DN).The ribbed cup style bearing achieved longer lives than the ribbed cone style. A standard bearing lasted only 10 minutes at 4000 rpm; however, the 30-min oil-off goal was achieved through 11000 rpm using the survivable ribbed cup bearing. The oil-off lives at 37000 rpm were less than 10 seconds. The grinding of the powder metal materials and surface preparation to achieve an open porosity is extremely critical to the oil-off performance of the powder metal component.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adey, D.; Appleby, R. B.; Bayes, R.

    Neutrino beams produced from the decay of muons in a racetrack-like decay ring (the so called Neutrino Factory) provide a powerful way to study neutrino oscillation physics and, in addition, provide unique beams for neutrino interaction studies. The Neutrinos from STORed Muons (nuSTORM) facility uses a neutrino factory-like design. Due to the particular nature of nuSTORM, it can also provide an intense, very pure, muon neutrino beam from pion decay. This so-called 'Neo-conventional' muon-neutrino beam from nuSTORM makes nuSTORM a hybrid neutrino factory. Here in this paper we describe the facility and give a detailed description of the neutrino beamsmore » that are available and the precision to which they can be characterized. We then show its potential for a neutrino interaction physics program and present sensitivity plots that indicate how well the facility can perform for short-baseline oscillation searches. Lastly, we comment on the performance potential of a 'Neo-conventional' muon neutrino beam optimized for long-baseline neutrino-oscillation physics.« less

  8. High current polarized electron source

    NASA Astrophysics Data System (ADS)

    Suleiman, R.; Adderley, P.; Grames, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.

    2018-05-01

    Jefferson Lab operates two DC high voltage GaAs photoguns with compact inverted insulators. One photogun provides the polarized electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) up to 200 µA. The other gun is used for high average current photocathode lifetime studies at a dedicated test facility up to 4 mA of polarized beam and 10 mA of un-polarized beam. GaAs-based photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed facilities that must operate in excess of tens of mA of polarized average current. This contribution describes techniques to maintain good vacuum while delivering high beam currents, and techniques that minimize damage due to ion bombardment, the dominant mechanism that reduces photocathode yield. Advantages of higher DC voltage include reduced space-charge emittance growth and the potential for better photocathode lifetime. Highlights of R&D to improve the performance of polarized electron sources and prolong the lifetime of strained-superlattice GaAs are presented.

  9. High Intensity Tests of the NuMI Beam Monitoring Ionization Chambers

    NASA Astrophysics Data System (ADS)

    Zwaska, Robert

    2002-04-01

    The NuMI facility at Fermilab will generate an intense beam of neutrinos directed toward Soudan, MN, 735 km away. Components of the planned beam monitoring system will be exposed to fluences of up to 8 x 10^9 charge particles / cm^2 and 6 x 10^10 neutrons / cm^2 in an 8.6 us beam spill. These fluences will be measured by an array of Helium ionization chambers. We tested a pair of chambers with 8 GeV protons at the Fermilab Booster accelerator, and with high intensity neutron sources at the Texas Experimental Nuclear Facility.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yokosawa, A.

    We summarize activities concerning the Fermilab polarized beams. They include a description of the polarized-beam facility, measurements of beam polarization by polarimeters, asymmetry measurements in the production at large x, and experiments with polarized beams during the next fixed-target period. 8 refs., 9 figs.

  11. [Optimal beam quality for chest digital radiography].

    PubMed

    Oda, Nobuhiro; Tabata, Yoshito; Nakano, Tsutomu

    2014-11-01

    To investigate the optimal beam quality for chest computed radiography (CR), we measured the radiographic contrast and evaluated the image quality of chest CR using various X-ray tube voltages. The contrast between lung and rib or heart increased on CR images obtained by lowering the tube voltage from 140 to 60 kV, but the degree of increase was less. Scattered radiation was reduced on CR images with a lower tube voltage. The Wiener spectrum of CR images with a low tube voltage showed a low value under identical conditions of amount of light stimulated emission. The quality of chest CR images obtained using a lower tube voltage (80 kV and 100 kV) was evaluated as being superior to those obtained with a higher tube voltage (120 kV and 140 kV). Considering the problem of tube loading and exposure in clinical applications, a tube voltage of 90 to 100 kV (0.1 mm copper filter backed by 0.5 mm aluminum) is recommended for chest CR.

  12. Selection of different reaction channels in 6Li induced fusion reaction by a powerful combination of a charged particle array and a high-resolution gamma spectrometer

    NASA Astrophysics Data System (ADS)

    Zhang, G. X.; Hu, S. P.; Zhang, G. L.; Zhang, H. Q.; Yao, Y. J.; Huang, Z.; Wang, M. L.; Sun, H. B.; Valiente-Dobòn, J. J.; Testov, D.; Goasduff, A.; John, P. R.; Siciliano, M.; Galtarosa, F.; Francesco, R.; Mengoni, D.; Bazzacco, D.; Li, E. T.; Hao, X.

    2018-05-01

    Investigation of the breakup and transfer effect of weakly bound nuclei on the fusion process has been an interesting research topic in the past several years. In comparison with radioactive ion beam (RIB), the beam intensities of stable weakly bound nuclei such as 6,7Li and 9Be, which have significant breakup probability, are orders of magnitude higher. Precise fusion measurements induced by these nuclei have already been performed. However, the conclusion of reaction dynamics was not clear and has contradiction. In order to have a proper understanding of the influence of breakup and transfer of weakly bound projectiles on the fusion process, the 6Li+89Y experiment with incident energies of 22 MeV and 34 MeV was performed on Galileo array in combination with Si-ball EUCLIDES at Legnaro National Laboratory (LNL) in Italy. Using the coincidence by the charged particles and γ-rays, the different reaction channels can be clearly identified.

  13. Free vibration analysis of a robotic fish based on a continuous and non-uniform flexible backbone with distributed masses

    NASA Astrophysics Data System (ADS)

    Coral, W.; Rossi, C.; Curet, O. M.

    2015-12-01

    This paper presents a Differential Quadrature Element Method for free transverse vibration of a robotic fish based on a continuous and non-uniform flexible backbone with distributed masses (fish ribs). The proposed method is based on the theory of a Timoshenko cantilever beam. The effects of the masses (number, magnitude and position) on the value of natural frequencies are investigated. Governing equations, compatibility and boundary conditions are formulated according to the Differential Quadrature rules. The convergence, efficiency and accuracy are compared to other analytical solution proposed in the literature. Moreover, the proposed method has been validate against the physical prototype of a flexible fish backbone. The main advantages of this method, compared to the exact solutions available in the literature are twofold: first, smaller computational cost and second, it allows analysing the free vibration in beams whose section is an arbitrary function, which is normally difficult or even impossible with other analytical methods.

  14. The Epidemiological, Morphological, and Clinical Aspects of the Cervical Ribs in Humans

    PubMed Central

    Spadliński, Łukasz; Cecot, Tomasz; Majos, Agata; Stefańczyk, Ludomir; Pietruszewska, Wioletta; Wysiadecki, Grzegorz; Topol, Mirosław

    2016-01-01

    A familiarity with the anatomy of some types of bone anomalies is necessary for clinicians involved in many medical areas. The aim of this paper is to review the newest literature concerning the morphology, embryology, clinical image, and therapeutic methods of the cervical ribs in the humans. The incidence of cervical ribs has been found to vary from 0.58% in Malaysian population to 6.2% in Turkish population. Cervical ribs have clinical implications that are generally divided into neurological or vascular. This study is of particular importance for clinicians, as early identification of cervical ribs may prevent life-threatening complications. PMID:27975060

  15. Multi-detector thoracic CT findings in cerebro-costo-mandibular syndrome: rib gaps and failure of costo-vertebral separation.

    PubMed

    Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan

    2014-02-01

    Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.

  16. Development of Technology for Image-Guided Proton Therapy

    DTIC Science & Technology

    2011-10-01

    testing proton RBE in the Penn proton beam facility  Assemble equipment and develop data analysis software  Install and test tablet PCs...production  Use dual-energy CT and MRI to determine the composition of materials Year 4 ending 9/30/2011  Measurement of RBE for protons using the...Penn proton beam facility  Measure LET for scattered and scanned beams  Enter forms on tablet PCs Phase 5 Scope of Work Year 1 ending 9

  17. A Surgical Procedure for Resecting the Mouse Rib: A Model for Large-Scale Long Bone Repair

    PubMed Central

    Funnell, John W.; Thein, Thu Zan Tun; Mariani, Francesca V.

    2015-01-01

    This protocol introduces researchers to a new model for large-scale bone repair utilizing the mouse rib. The procedure details the following: preparation of the animal for surgery, opening the thoracic body wall, exposing the desired rib from the surrounding intercostal muscles, excising the desired section of rib without inducing a pneumothorax, and closing the incisions. Compared to the bones of the appendicular skeleton, the ribs are highly accessible. In addition, no internal or external fixator is necessary since the adjacent ribs provide a natural fixation. The surgery uses commercially available supplies, is straightforward to learn, and well-tolerated by the animal. The procedure can be carried out with or without removing the surrounding periosteum, and therefore the contribution of the periosteum to repair can be assessed. Results indicate that if the periosteum is retained, robust repair occurs in 1 - 2 months. We expect that use of this protocol will stimulate research into rib repair and that the findings will facilitate the development of new ways to stimulate bone repair in other locations around the body. PMID:25651082

  18. Flexural performance of steel fiber reinforced concrete (SFRC) ribbed slab with various topping thicknesses

    NASA Astrophysics Data System (ADS)

    Rahman, Fadhillah Abdul; Bakar, Afidah Abu; Hashim, Mohd Hisbany Mohd; Ahmad, Hazrina

    2017-11-01

    Ribbed slab provides lighter slab than an equivalent solid slab which helps in reducing the weight with its voids. However, in order to overcome the drawbacks in the construction process, the application of steel fibre reinforcement concrete (SFRC) is seen as an alternative material to be used in the slab. This study is performed to investigate the behaviour of SFRC as the main material in ribbed slab, omitting the conventional reinforcements, under four-point bending test. Three equivalent samples of ribbed slabs were prepared for this study with variations in the topping thickness of 100, 75 and 50 mm. The flexural strength of ribbed slab with 100 mm topping shows similar loading carrying capacity with the 75mm topping while 50 mm gave the lowest ultimate loading. First cracks for all slabs occurred at the topping. The cracks began from the external ribs and propagates toward the internal rib. Incorporation of steel fibres help in giving a longer deflection softening than a sudden brittle failure, thus proves its ability to increase energy absorption capacity and improving cracking behaviour.

  19. Experimental investigation of the effect of variously-shaped ribs on local heat transfer on the outer wall of the turning portion of a U-channel inside solar air heater

    NASA Astrophysics Data System (ADS)

    Salameh, Tareq; Alami, Abdul Hai; Sunden, Bengt

    2016-03-01

    In the present work, an experimental investigation of convective heat transfer and pressure drop was carried out for the turning portion of a U-channel where the outer wall was equipped with ribs. The shape of the ribs was varied. The investigation aims to give guidelines for improving the thermo-hydraulic performance of a solar air heater at the turning portion of a U-channel. Both the U-channel and the ribs were made in acrylic material to allow optical access for measuring the surface temperature by using a high-resolution technique based on narrow band thermochromic liquid crystals (TLC R35C5 W) and a CCD camera placed to face the turning portion of the U-channel. The uncertainties were estimated to 5 and 7 % for the Nusselt number and friction factor, respectively. The pressure drop was approximately the same for all the considered shapes of the ribs while the dimpled rib case gave the highest heat transfer coefficient while the grooved rib presented the highest performance index.

  20. A case of pathological rib fractures: focal osteolysis or osteoporosis?

    PubMed

    Vrbanić, T S L; Novak, S; Sestan, B; Tudor, A; Gulan, G

    2008-03-01

    This paper reports on a unique, previously unreported, successful outcome in the case of a patient with focal osteolytic lesions of the ribs as a first sign of osteoporosis. The lesions were detected by chance after acute cough-induced rib fractures were seen on plain chest radiographs. The diagnosis had to be approached as a diagnosis of exclusion since known causes of the osteolytic process had to be eliminated. The authors describe multiple focal osteolytic lesions with rib fractures appearing in a pattern that could be confused with metastases. Laboratory results were normal. Final diagnosis was based on plain radiography, bone scan and bone densitometry. Pharmacomedical treatments for osteoporosis were applied. The patient was observed between the year 2000 and 2005. Five years later radiological and bone scintigraphy revealed resolution of the lesion. We conclude that osteoporosis should be included in the differential diagnosis of asymptomatic focal osteolysis of the ribs with rib fractures as a complication of acute cough. The case suggests that focal osteolytic lesions of the ribs may regress over time and become scintigraphically inactive.

  1. Heat transfer performance comparison of steam and air in gas turbine cooling channels with different rib angles

    NASA Astrophysics Data System (ADS)

    Shi, Xiaojun; Gao, Jianmin; Xu, Liang; Li, Fajin

    2013-11-01

    Using steam as working fluid to replace compressed air is a promising cooling technology for internal cooling passages of blades and vanes. The local heat transfer characteristics and the thermal performance of steam flow in wide aspect ratio channels ( W/ H = 2) with different angled ribs on two opposite walls have been experimentally investigated in this paper. The averaged Nusselt number ratios and the friction factor ratios of steam and air in four ribbed channels were also measured under the same test conditions for comparison. The Reynolds number range is 6,000-70,000. The rib angles are 90°, 60°, 45°, and 30°, respectively. The rib height to hydraulic diameter ratio is 0.047. The pitch-to-rib height ratio is 10. The results show that the Nusselt number ratios of steam are 1.19-1.32 times greater than those of air over the range of Reynolds numbers studied. For wide aspect ratio channels using steam as the coolant, the 60° angled ribs has the best heat transfer performance and is recommended for cooling design.

  2. Thomas Jefferson National Accelerator Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grames, Joseph; Higinbotham, Douglas; Montgomery, Hugh

    The Thomas Jefferson National Accelerator Facility (Jefferson Lab) in Newport News, Virginia, USA, is one of ten national laboratories under the aegis of the Office of Science of the U.S. Department of Energy (DOE). It is managed and operated by Jefferson Science Associates, LLC. The primary facility at Jefferson Lab is the Continuous Electron Beam Accelerator Facility (CEBAF) as shown in an aerial photograph in Figure 1. Jefferson Lab was created in 1984 as CEBAF and started operations for physics in 1995. The accelerator uses superconducting radio-frequency (srf) techniques to generate high-quality beams of electrons with high-intensity, well-controlled polarization. Themore » technology has enabled ancillary facilities to be created. The CEBAF facility is used by an international user community of more than 1200 physicists for a program of exploration and study of nuclear, hadronic matter, the strong interaction and quantum chromodynamics. Additionally, the exceptional quality of the beams facilitates studies of the fundamental symmetries of nature, which complement those of atomic physics on the one hand and of high-energy particle physics on the other. The facility is in the midst of a project to double the energy of the facility and to enhance and expand its experimental facilities. Studies are also pursued with a Free-Electron Laser produced by an energy-recovering linear accelerator.« less

  3. Formation of a uniform ion beam using octupole magnets for BioLEIR facility at CERN

    NASA Astrophysics Data System (ADS)

    Amin, T.; Barlow, R.; Ghithan, S.; Roy, G.; Schuh, S.

    2018-04-01

    The possibility to transform the Low Energy Ion Ring (LEIR) accelerator at CERN into a multidisciplinary, biomedical research facility (BioLEIR) was investigated based on a request from the biomedical community. BioLEIR aims to provide a unique facility with a range of fully stripped ion beams (e.g. He, Li, Be, B, C, N, O) and energies suitable for multidisciplinary biomedical, clinically-oriented research. Two horizontal and one vertical beam transport lines have been designed for transporting the extracted beam from LEIR to three experimental end-stations. The vertical beamline was designed for a maximum energy of 75 MeV/u, while the two horizontal beamlines shall deliver up to a maximum energy of 440 MeV/u. A pencil beam of 4.3 mm FWHM (Full Width Half Maximum) as well as a homogeneous broad beam of 40 × 40 mm2, with a beam homogeneity better than ±4%, are available at the first horizontal (H1) irradiation point, while only a pencil beam is available at the second horizontal (H2) and vertical (V) irradiation points. The H1 irradiation point shall be used to conduct systematic studies of the radiation effect from different ion species on cell-lines. The H1 beamline was designed to utilize two octupole magnets which transform the Gaussian beam distribution at the target location into an approximately uniformly distributed rectangular beam. In this paper, we report on the multi-particle tracking calculations performed using MAD-X software suite for the H1 beam optics to arrive at a homogeneous broad beam on target using nonlinear focusing techniques, and on those to create a Gaussian pencil beam on target by adjusting quadrupoles strengths and positions.

  4. Thoracic Injury Risk Curves for Rib Deflections of the SID-IIs Build Level D.

    PubMed

    Irwin, Annette L; Crawford, Greg; Gorman, David; Wang, Sikui; Mertz, Harold J

    2016-11-01

    Injury risk curves for SID-IIs thorax and abdomen rib deflections proposed for future NCAP side impact evaluations were developed from tests conducted with the SID-IIs FRG. Since the floating rib guide is known to reduce the magnitude of the peak rib deflections, injury risk curves developed from SID-IIs FRG data are not appropriate for use with SID-IIs build level D. PMHS injury data from three series of sled tests and one series of whole-body drop tests are paired with thoracic rib deflections from equivalent tests with SID-IIs build level D. Where possible, the rib deflections of SID-IIs build level D were scaled to adjust for differences in impact velocity between the PMHS and SID-IIs tests. Injury risk curves developed by the Mertz-Weber modified median rank method are presented and compared to risk curves developed by other parametric and non-parametric methods.

  5. Costal cartilage fractures and disruptions in a rugby football player.

    PubMed

    Lopez, Victor; Ma, Richard; Li, Xinning; Steele, John; Allen, Answorth A

    2013-05-01

    Costal cartilage fracture of the rib cage, or costochondral, is a rare sporting injury. For contact athletes, the instability of the rib cage may lead to potential serious complications, similar to rib fractures or thorax disruption. Most authors recommend initial conservative treatment with surgery reserved for only recalcitrant cases. We report a case of an amateur American male rugby football player who sustained a costal cartilage fracture and disruption involving the anterior left fifth and sixth rib costal cartilages. The case highlights the difficulty in establishing the diagnosis based on clinical examination and standard radiographs alone. Computed tomography was used to assist in diagnosing this destabilizing injury to the rib cage. Costal cartilage fractures and disruptions in athletes are rarely reported in the literature and can have serious implications for the athlete's ability to return to play if the rib cage is destabilized.

  6. Visualization of the influence of the air conditioning system to the high-power laser beam quality with the modulation coherent imaging method.

    PubMed

    Tao, Hua; Veetil, Suhas P; Pan, Xingchen; Liu, Cheng; Zhu, Jianqiang

    2015-08-01

    Air conditioning systems can lead to dynamic phase change in the laser beams of high-power laser facilities for the inertial confinement fusion, and this kind of phase change cannot be measured by most of the commonly employed Hartmann wavefront sensor or interferometry due to some uncontrollable factors, such as too large laser beam diameters and the limited space of the facility. It is demonstrated that this problem can be solved using a scheme based on modulation coherent imaging, and thus the influence of the air conditioning system on the performance of the high-power facility can be evaluated directly.

  7. The ISOLDE facility

    NASA Astrophysics Data System (ADS)

    Catherall, R.; Andreazza, W.; Breitenfeldt, M.; Dorsival, A.; Focker, G. J.; Gharsa, T. P.; J, Giles T.; Grenard, J.-L.; Locci, F.; Martins, P.; Marzari, S.; Schipper, J.; Shornikov, A.; Stora, T.

    2017-09-01

    The ISOLDE facility has undergone numerous changes over the last 17 years driven by both the physics and technical community with a common goal to improve on beam variety, beam quality and safety. Improvements have been made in civil engineering and operational equipment while continuing developments aim to ensure operations following a potential increase in primary beam intensity and energy. This paper outlines the principal technical changes incurred at ISOLDE by building on a similar publication of the facility upgrades by Kugler (2000 Hyperfine Interact. 129 23-42). It also provides an insight into future perspectives through a brief summary issues addressed in the HIE-ISOLDE design study Catherall et al (2013 Nucl. Instrum. Methods Phys. Res. B 317 204-207).

  8. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins].

    PubMed

    Liu, Jinliang; Li, Keyao; He, Jianning

    2011-01-01

    To study the indications, methods, and therapeutic effect of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. Between March 2007 and September 2009, 40 patients with multiple rib fractures received internal fixation with absorbable rib-connecting-pins, including 8 one-side flail chest and 1 two-side flail chest. There were 32 males and 8 females with an average age of 39.8 years (range, 25-72 years). The injury was caused by traffic accident in 32 cases, falling from height in 6 cases, and blunt hitting in 2 cases. Preoperatively, imaging data of the chest X-ray or spiral CT three-dimensional (3D) examination showed that all patients had multiple ribs fractures and displacement. The number of fractured ribs was 4-10 (median, 6), and the fracture location ranged from the 2nd to the 10th ribs. Of them, 28 cases were accompanied by hemathorax, pneumothorax or hemopneumothorax; 5 cases by thoracic organ injury; and 10 cases by other part trauma. The time from injury to hospitalization was less than 1 day in 26 cases, 1-3 days in 12 cases, and 3-6 days in 2 cases, and the time from hospitalization to operation was 3 hours to 3 days (mean, 1.2 days). The median fixation rib number was 5 (range, 3-8). The mean operative time, the time in bed, and hospitalization days were 32 minutes (range, 15-50 minutes), 4.5 days (range, 2-7 days), and 11.2 days (range, 5-18 days), respectively. All incisions healed by first intention. No pulmonary infection, pulmonary atelectasis, intrathoracic infection or other complications occurred. All cases were followed up 6-12 months (mean, 8 months). PaO2 [(86.6 +/- 2.2) mmHg (1 mm Hg = 0.133 kPa)] and SpO2 (97.2% +/- 0.6%) at 2 hours after operation were obviously improved when compared with preoperative ones (PaO2 (53.6 + 4.7) mm Hg and SpO2 (86.2% + 1.8%)], showing significant differences (t = 2.971, P = 0.005; t = 2.426, P = 0.020). The chest X-ray films or spiral CT 3D indicated that fracture of rib healed within 3-6 months (mean, 4.5 months) after operation. Severe collapsed chest wall or flail chest caused by fracture of multiple ribs should be treated by absorbable rib-connecting-pins, which is a simple, firm, and effective method.

  9. Long pulse acceleration of MeV class high power density negative H{sup −} ion beam for ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umeda, N., E-mail: umeda.naotaka@jaea.go.jp; Kojima, A.; Kashiwagi, M.

    2015-04-08

    R and D of high power density negative ion beam acceleration has been carried out at MeV test facility in JAEA to realize ITER neutral beam accelerator. The main target is H{sup −} ion beam acceleration up to 1 MeV with 200 A/m{sup 2} for 60 s whose pulse length is the present facility limit. For long pulse acceleration at high power density, new extraction grid (EXG) has been developed with high cooling capability, which electron suppression magnet is placed under cooling channel similar to ITER. In addition, aperture size of electron suppression grid (ESG) is enlarged from 14 mmmore » to 16 mm to reduce direct interception on the ESG and emission of secondary electron which leads to high heat load on the upstream acceleration grid. By enlarging ESG aperture, beam current increased 10 % at high current beam and total acceleration grid heat load reduced from 13 % to 10 % of input power at long pulse beam. In addition, heat load by back stream positive ion into the EXG is measured for the first time and is estimated as 0.3 % of beam power, while heat load by back stream ion into the source chamber is estimated as 3.5 ~ 4.0 % of beam power. Beam acceleration up to 60 s which is the facility limit, has achieved at 683 keV, 100 A/m{sup 2} of negative ion beam, whose energy density increases two orders of magnitude since 2011.« less

  10. Supersonic Wing Optimization Using SpaRibs

    NASA Technical Reports Server (NTRS)

    Locatelli, David; Mulani, Sameer B.; Liu, Qiang; Tamijani, Ali Y.; Kapania, Rakesh K.

    2014-01-01

    This research investigates the advantages of using curvilinear spars and ribs, termed SpaRibs, to design a supersonic aircraft wing-box in comparison to the use of classic design concepts that employ straight spars and ribs. The objective is to achieve a more efficient load-bearing mechanism and to passively control the deformation of the structure under the flight loads. Moreover, the use of SpaRibs broadens the design space and allows for natural frequencies and natural mode shape tailoring. The SpaRibs concept is implemented in a new optimization MATLAB-based framework referred to as EBF3SSWingOpt. This optimization scheme performs both the sizing and the shaping of the internal structural elements, connecting the optimizer with the analysis software. The shape of the SpaRibs is parametrically defined using the so called Linked Shape method. Each set of SpaRibs is placed in a one by one square domain of the natural space. The set of curves is subsequently transformed in the physical space for creating the wing structure geometry layout. The shape of each curve of each set is unique; however, mathematical relations link the curvature in an effort to reduce the number of design variables. The internal structure of a High Speed Commercial Transport aircraft concept developed by Boeing is optimized subjected to stress, subsonic flutter and supersonic flutter constraints. The results show that the use of the SpaRibs allows for the reduction of the aircraft's primary structure weight without violating the constraints. A weight reduction of about 15 percent is observed.

  11. Use of a 90° drill and screwdriver for rib fracture stabilization.

    PubMed

    Nickerson, Terry P; Kim, Brian D; Zielinski, Martin D; Jenkins, Donald; Schiller, Henry J

    2015-03-01

    Rib fracture stabilization has become a more accepted practice although stabilization of the most cephalad ribs presents a unique challenge. We present our experience with use of a 90° drill and screwdriver to bridge these difficult rib fractures. This retrospective review included patients who underwent rib fracture stabilization from August 1, 2009, through September 30, 2012. Patients were divided into two groups: those whose procedure used the 90° device and those that did not. Data were compared using standard statistical analysis and reported as percentages and medians [interquartile ranges]. P values <0.05 were considered significant. We identified 89 patients: 29 (33%) had 90° devices used and 60 (67%) did not. There were no differences between groups in age, sex, Trauma-Related Injury Severity Score, the presence of flail chest, occurrence of pneumonia, and intensive care unit or hospital length of stay. The Injury Severity Score was higher in the 90° group (22 vs. 16; P = 0.03). The highest rib stabilized was different between the 2 groups (3 [2-5] vs. 5 [2-9]; P = 0.001), with more third rib stabilizations in the 90° group (38 vs. 20%; P = 0.04) as well as more total number of ribs fixed (5 vs. 4; P = 0.001). There was no difference in operative time between the 2 groups. The surgical reach for rib fracture stabilization has been extended with use of a 90° drill and screwdriver. High fractures under the scapula where access is technically challenging can be stabilized without prolonging operative times.

  12. Mach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section

    PubMed Central

    Yuan, Dengpeng; Dong, Ying; Liu, Yujin; Li, Tianjian

    2015-01-01

    A high-sensitivity Mach-Zehnder interferometer (MZI) biochemical sensing platform based on Silicon-in-insulator (SOI) rib waveguide with large cross section is proposed in this paper. Based on the analyses of the evanescent field intensity, the mode polarization and cross section dimensions of the SOI rib waveguide are optimized through finite difference method (FDM) simulation. To realize high-resolution MZI read-out configuration based on the SOI rib waveguide, medium-filled trenches are employed and their performances are simulated through two-dimensional finite-difference-time domain (2D-FDTD) method. With the fundamental EH-polarized mode of the SOI rib waveguide with a total rib height of 10 μm, an outside rib height of 5 μm and a rib width of 2.5 μm at the operating wavelength of 1550 nm, when the length of the sensitive window in the MZI configuration is 10 mm, a homogeneous sensitivity of 7296.6%/refractive index unit (RIU) is obtained. Supposing the resolutions of the photoelectric detectors connected to the output ports are 0.2%, the MZI sensor can achieve a detection limit of 2.74 × 10−6 RIU. Due to high coupling efficiency of SOI rib waveguide with large cross section with standard single-mode glass optical fiber, the proposed MZI sensing platform can be conveniently integrated with optical fiber communication systems and (opto-) electronic systems, and therefore has the potential to realize remote sensing, in situ real-time detecting, and possible applications in the internet of things. PMID:26343678

  13. New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment.

    PubMed

    Glemser, Philip A; Pfleiderer, Michael; Heger, Anna; Tremper, Jan; Krauskopf, Astrid; Schlemmer, Heinz-Peter; Yen, Kathrin; Simons, David

    2017-03-01

    The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as "unfolding" visualizations of the rib cage (modality C, "eagle tool"). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.

  14. Prevalence of Abuse Among Young Children with Rib Fractures: A Systematic Review

    PubMed Central

    Paine, Christine Weirich; Fakeye, Oludolapo; Christian, Cindy W.; Wood, Joanne N.

    2016-01-01

    Objectives We aimed to estimate the prevalence of abuse in young children presenting with rib fractures and to identify demographic, injury, and presentation-related characteristics that affect the probability that rib fractures are secondary to abuse. Methods We searched PubMed/MEDLINE and CINAHL databases for articles published in English between January 1, 1990 and June 30, 2014 on rib fracture etiology in children ≤ 5 years old. Two reviewers independently extracted predefined data elements and assigned quality ratings to included studies. Study-specific abuse prevalences and the sensitivities, specificities, and positive and negative likelihood ratios of patients’ demographic and clinical characteristics for abuse were calculated with 95% confidence intervals. Results Data for 1,396 children ≤ 48 months old with rib fractures were abstracted from 10 articles. Among infants < 12 months old, abuse prevalence ranged from 67% to 84%, whereas children 12-23 months old and 24-35 months old had study-specific abuse prevalences of 29% and 28% respectively. Age < 12 months was the only characteristic significantly associated with increased likelihood of abuse across multiple studies. Rib fracture location was not associated with likelihood of abuse. The retrospective design of the included studies and variations in ascertainment of cases, inclusion/exclusion criteria, and child abuse assessments prevented further meta-analysis. Conclusions Abuse is the most common cause of rib fractures in infants < 12 months old. Prospective studies with standardized methods are needed to improve accuracy in determining abuse prevalence among children with rib fractures and characteristics associated with abusive rib fractures. PMID:27749806

  15. Outcomes after operative management of symptomatic rib nonunion.

    PubMed

    Gauger, Erich M; Hill, Brian W; Lafferty, Paul M; Cole, Peter A

    2015-06-01

    To report the outcomes of rib reconstruction after painful nonunion. Retrospective case series. Level I trauma center. Between November 2007 and May 2013, 10 patients who presented with 16 rib nonunions and disabling pain were treated with reconstruction of their nonunited rib fractures. Rib nonunion reconstruction predominately with iliac crest bone graft and a tension band plate with a locked precontoured plating system for ribs. Demographic data, mechanism of injury, and number of rib nonunions were recorded. Operative procedure, length of follow-up, complications, Short Form Survey 36, and a patient questionnaire were also captured and documented. Eight of the 10 patients sustained their original fractures from a fall. Outcomes were available for the 10 patients at a mean follow-up of up of 18.6 months (range, 3-46 months). All 16 ribs went on to union with a mean time from reconstruction to union of 14.7 weeks (range, 12-24 weeks). At final follow-up, the mean mental and physical component Short Form Survey 36 scores were 54.4 and 43.5, respectively. Eight of the 10 patients were able to return to work and/or previous activities without limitations. Complications included 1 wound infection that resolved after irrigation and debridement with adjunctive antibiotics. One symptomatic implant was removed. Ten patients with 16 symptomatic rib nonunions were reconstructed using autologous bone graft and implant/mesh fixation manifesting in successful union with improved patient function and a low rate of complications. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  16. 21. Detail of steel ribs at south wall, T18; Note ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Detail of steel ribs at south wall, T-18; Note composition of ribs--two steel channels welded together - Advance Base Depot Davisville, Building T-17, Ninth Street southeast of Davisville Road, Davisville, Washington County, RI

  17. Clinical prognostic factors and grading system for rib fracture following stereotactic body radiation therapy (SBRT) in patients with peripheral lung tumors.

    PubMed

    Kim, Su Ssan; Song, Si Yeol; Kwak, Jungwon; Ahn, Seung Do; Kim, Jong Hoon; Lee, Jung Shin; Kim, Woo Sung; Kim, Sang-We; Choi, Eun Kyung

    2013-02-01

    Several studies reported rib fractures following stereotactic body radiation therapy (SBRT) for peripheral lung tumors. We tried to investigate risk factors and grading system for rib fractures after SBRT. Of 375 primary or metastatic lung tumors (296 patients) which were treated with SBRT at the Asan Medical Center (2006-2009), 126 lesions (118 patients) were adjacent to the chest-wall (<1cm) and followed-up with chest computed tomography (CT) for >6 months; these were investigated in the present retrospective study. Three to four fractional doses of 10-20 Gy were delivered to 85-90% iso-dose volume of the isocenter dose. Rib fracture grade was defined from follow-up CT scans as the appearance of a fracture line (Gr1), dislocation of the fractured rib by more than half the rib diameter (Gr2), or the appearance of adjacent soft tissue edema (Gr3). Chest wall pain was assessed according to the Common Terminology Criteria for Adverse Events (CTCAE) v3.0. Correlations between dose-volume data and the development of rib fracture were then analyzed. The Kaplan-Meier method, log-rank tests, and chi-square tests were used for statistical analysis. The median age of the patients was 69 years (range: 19-90). Over a median follow-up period of 22 months (range: 7-62), 48 cases of rib fracture were confirmed. Median time to rib fracture was 17 months (range: 4-52). The 2-year actuarial risk of rib fracture was 42.4%. Maximal grade was Gr1 (n=28), Gr2 (n=8), or Gr3 (n=15). The incidence of moderate to severe chest wall pain (CTCAE Gr ≥ 2) increased with maximal fracture grade (17.5% for Gr0-1 and 60.9% for Gr2-3; p<0.001). Multivariate analysis identified female gender, lateral location, and the dose to the 8cc of the chest wall as significant prognostic factors. Female gender and lateral tumor location were clinical risk factors for rib fracture in the present study. Efforts to decrease chest wall dose should be made to reduce the risk of the rib fracture, particularly in high-risk patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Systemic administration of mesenchymal stem cells combined with parathyroid hormone therapy synergistically regenerates multiple rib fractures.

    PubMed

    Cohn Yakubovich, Doron; Sheyn, Dmitriy; Bez, Maxim; Schary, Yeshai; Yalon, Eran; Sirhan, Afeef; Amira, May; Yaya, Alin; De Mel, Sandra; Da, Xiaoyu; Ben-David, Shiran; Tawackoli, Wafa; Ley, Eric J; Gazit, Dan; Gazit, Zulma; Pelled, Gadi

    2017-03-09

    A devastating condition that leads to trauma-related morbidity, multiple rib fractures, remain a serious unmet clinical need. Systemic administration of mesenchymal stem cells (MSCs) has been shown to regenerate various tissues. We hypothesized that parathyroid hormone (PTH) therapy would enhance MSC homing and differentiation, ultimately leading to bone formation that would bridge rib fractures. The combination of human MSCs (hMSCs) and a clinically relevant PTH dose was studied using immunosuppressed rats. Segmental defects were created in animals' fifth and sixth ribs. The rats were divided into four groups: a negative control group, in which animals received vehicle alone; the PTH-only group, in which animals received daily subcutaneous injections of 4 μg/kg teriparatide, a pharmaceutical derivative of PTH; the hMSC-only group, in which each animal received five injections of 2 × 10 6 hMSCs; and the hMSC + PTH group, in which animals received both treatments. Longitudinal in vivo monitoring of bone formation was performed biweekly using micro-computed tomography (μCT), followed by histological analysis. Fluorescently-dyed hMSCs were counted using confocal microscopy imaging of histological samples harvested 8 weeks after surgery. PTH significantly augmented the number of hMSCs that homed to the fracture site. Immunofluorescence of osteogenic markers, osteocalcin and bone sialoprotein, showed that PTH induced cell differentiation in both exogenously administered cells and resident cells. μCT scans revealed a significant increase in bone volume only in the hMSC + PTH group, beginning by the 4 th week after surgery. Eight weeks after surgery, 35% of ribs in the hMSC + PTH group had complete bone bridging, whereas there was complete bridging in only 6.25% of ribs (one rib) in the PTH-only group and in none of the ribs in the other groups. Based on the μCT scans, biomechanical analysis using the micro-finite element method demonstrated that the healed ribs were stiffer than intact ribs in torsion, compression, and bending simulations, as expected when examining bone callus composed of woven bone. Administration of both hMSCs and PTH worked synergistically in rib fracture healing, suggesting this approach may pave the way to treat multiple rib fractures as well as additional fractures in various anatomical sites.

  19. The drift chamber array at the external target facility in HIRFL-CSR

    NASA Astrophysics Data System (ADS)

    Sun, Y. Z.; Sun, Z. Y.; Wang, S. T.; Duan, L. M.; Sun, Y.; Yan, D.; Tang, S. W.; Yang, H. R.; Lu, C. G.; Ma, P.; Yu, Y. H.; Zhang, X. H.; Yue, K.; Fang, F.; Su, H.

    2018-06-01

    A drift chamber array at the External Target Facility in HIRFL-CSR has been constructed for three-dimensional particle tracking in high-energy radioactive ion beam experiments. The design, readout, track reconstruction program and calibration procedures for the detector are described. The drift chamber array was tested in a 311 AMeV 40Ar beam experiment. The detector performance based on the measurements of the beam test is presented. A spatial resolution of 230 μm is achieved.

  20. An ion source module for the Beijing Radioactive Ion-beam Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, B., E-mail: cui@ciae.ac.cn; Huang, Q.; Tang, B.

    2014-02-15

    An ion source module is developed for Beijing Radioactive Ion-beam Facility. The ion source module is designed to meet the requirements of remote handling. The connection and disconnection of the electricity, cooling and vacuum between the module and peripheral units can be executed without on-site manual work. The primary test of the target ion source has been carried out and a Li{sup +} beam has been extracted. Details of the ion source module and its primary test results are described.

  1. Measuring Three-Dimensional Thorax Motion Via Biplane Radiographic Imaging: Technique and Preliminary Results.

    PubMed

    Baumer, Timothy G; Giles, Joshua W; Drake, Anne; Zauel, Roger; Bey, Michael J

    2016-01-01

    Measures of scapulothoracic motion are dependent on accurate imaging of the scapula and thorax. Advanced radiographic techniques can provide accurate measures of scapular motion, but the limited 3D imaging volume of these techniques often precludes measurement of thorax motion. To overcome this, a thorax coordinate system was defined based on the position of rib pairs and then compared to a conventional sternum/spine-based thorax coordinate system. Alignment of the rib-based coordinate system was dependent on the rib pairs used, with the rib3:rib4 pairing aligned to within 4.4 ± 2.1 deg of the conventional thorax coordinate system.

  2. Successful management of threatened aortic rupture late after rib fracture caused by blunt chest trauma.

    PubMed

    Morimoto, Yoshihisa; Sugimoto, Takaki; Sakahira, Hideki; Matsuoka, Hidehito; Yoshioka, Yuki; Arase, Hiroki

    2014-05-01

    A 62-year-old man was crushed in a car accident and diagnosed with a fractured left ninth rib, pulmonary and heart contusion, hemopneumothorax, and descending aortic injury based on a computed tomography scan. He underwent chest tube drainage and was intubated for mechanical ventilation because a bone fragment of the ninth rib threatened to penetrate the descending aorta. On the second posttrauma day, computed tomography showed the bone fragment of the ninth rib approaching the descending aorta. He underwent graft replacement of the injured portion of the descending thoracic aorta, and we removed the fractured left ninth rib. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Fermilab | Science | Particle Accelerators | Advanced Superconducting Test

    Science.gov Websites

    Accelerators for science and society Particle Physics 101 Science of matter, energy, space and time How Technology (FAST) Facility is America's only test bed for cutting-edge, record high-intensity particle beams in the United States as a particle beam research facility based on superconducting radio-frequency

  4. ToF diagnostic of Tin resonant laser photoionization in SPES laser offline laboratory

    NASA Astrophysics Data System (ADS)

    Scarpa, D.; Fedorov, D.; Andrighetto, A.; Mariotti, E.; Nicolosi, P.; Sottili, L.; Tomaselli, A.; Cecchi, R.; Stiaccini, L.

    2016-09-01

    Tin is the principal element of interest in the SPES ISOL facility, which is under construction at Legnaro INFN Laboratories. Atomic nuclei have a shell structure in which nuclei with \\textquoteleft magic numbers\\textquoteright of protons and neutrons are analogous to the noble gasses in atomic physics. In particular, recent theoretical studies, reveal double-magic nature of radioactive 132Sn. For this reason the nuclear physics community demonstrated, in the last years, a huge interest to produce and study this radioactive neutron rich isotope. Experiments on Tin laser resonant ionization have been performed in the offline SPES laser laboratory to investigate the capability of the new home-made Time of Flight (ToF) mass spectrometer. Several three-step, two color ionization schemes have been tested by comparing fast and slow optogalvanic signals from a Tin Hollow Cathode Lamp (HCL) and Time of Flight signals from the spectrometer. By scanning the wavelength of one of the two dye lasers across the specific resonance, comparisons of ionization signals from both the ToF and the HCL have been made, finding perfect agreement. Furthermore, with the mass spectrometer, resolved peaks of all the natural Tin isotopes have been detected. The natural abundances extracted from these measurements are in agreement with the table values for Tin isotopes. This work, with comparison of OGE and ToF signals, confirm the fully functional SPES offline laser laboratory capability in order to develop scheme studies also for the other possible Radioactive Ion Beam (RIB) elements.

  5. Measurements and analyses of the distribution of the radioactivity induced by the secondary neutrons produced by 17-MeV protons in compact cyclotron facility

    NASA Astrophysics Data System (ADS)

    Matsuda, Norihiro; Izumi, Yuichi; Yamanaka, Yoshiyuki; Gandou, Toshiyuki; Yamada, Masaaki; Oishi, Koji

    2017-09-01

    Measurements of reaction rates by secondary neutrons produced from beam losses by 17-MeV protons are conducted at a compact cyclotron facility with the foil activation method. The experimentally obtained distribution of the reaction rates of 197Au (n, γ) 198Au on the concrete walls suggests that a target and an electrostatic deflector as machine components for beam extraction of the compact cyclotron are principal beam loss points. The measurements are compared with calculations by the Monte Carlo code: PHITS. The calculated results based on the beam losses are good agreements with the measured ones within 21%. In this compact cyclotron facility, exponential attenuations with the distance from the electrostatic deflector in the distributions of the measured reaction rates were observed, which was looser than that by the inverse square of distance.

  6. Physics opportunities with meson beams

    DOE PAGES

    Briscoe, William J.; Doring, Michael; Haberzettl, Helmut; ...

    2015-10-20

    Over the past two decades, meson photo- and electro-production data of unprecedented quality and quantity have been measured at electromagnetic facilities worldwide. By contrast, the meson-beam data for the same hadronic final states are mostly outdated and largely of poor quality, or even nonexistent, and thus provide inadequate input to help interpret, analyze, and exploit the full potential of the new electromagnetic data. To reap the full benefit of the high-precision electromagnetic data, new high-statistics data from measurements with meson beams, with good angle and energy coverage for a wide range of reactions, are critically needed to advance our knowledgemore » in baryon and meson spectroscopy and other related areas of hadron physics. To address this situation, a state of-the-art meson-beam facility needs to be constructed. Furthermore, the present paper summarizes unresolved issues in hadron physics and outlines the vast opportunities and advances that only become possible with such a facility.« less

  7. Physics opportunities with meson beams

    NASA Astrophysics Data System (ADS)

    Briscoe, William J.; Döring, Michael; Haberzettl, Helmut; Manley, D. Mark; Naruki, Megumi; Strakovsky, Igor I.; Swanson, Eric S.

    2015-10-01

    Over the past two decades, meson photo- and electroproduction data of unprecedented quality and quantity have been measured at electromagnetic facilities worldwide. By contrast, the meson-beam data for the same hadronic final states are mostly outdated and largely of poor quality, or even non-existent, and thus provide inadequate input to help interpret, analyze, and exploit the full potential of the new electromagnetic data. To reap the full benefit of the high-precision electromagnetic data, new high-statistics data from measurements with meson beams, with good angle and energy coverage for a wide range of reactions, are critically needed to advance our knowledge in baryon and meson spectroscopy and other related areas of hadron physics. To address this situation, a state-of-the-art meson-beam facility needs to be constructed. The present paper summarizes unresolved issues in hadron physics and outlines the vast opportunities and advances that only become possible with such a facility.

  8. Integrated development facility for the calibration of low-energy charged particle flight instrumentation

    NASA Technical Reports Server (NTRS)

    Biddle, A. P.; Reynolds, J. M.

    1986-01-01

    The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

  9. Electrical-thermal-structural finite element simulation and experimental study of a plasma ion source for the production of radioactive ion beams

    NASA Astrophysics Data System (ADS)

    Manzolaro, M.; Meneghetti, G.; Andrighetto, A.; Vivian, G.

    2016-03-01

    The production target and the ion source constitute the core of the selective production of exotic species (SPES) facility. In this complex experimental apparatus for the production of radioactive ion beams, a 40 MeV, 200 μA proton beam directly impinges a uranium carbide target, generating approximately 1013 fissions per second. The transfer line enables the unstable isotopes generated by the 238U fissions in the target to reach the ion source, where they can be ionized and finally accelerated to the subsequent areas of the facility. In this work, the plasma ion source currently adopted for the SPES facility is analyzed in detail by means of electrical, thermal, and structural numerical models. Next, theoretical results are compared with the electric potential difference, temperature, and displacement measurements. Experimental tests with stable ion beams are also presented and discussed.

  10. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    PubMed

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  11. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    PubMed Central

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity. PMID:26175916

  12. Research of beam conditioning technologies on SG-III laser facility

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Su, Jingqin; Yuan, Haoyu; Li, Ping; Tian, Xiaocheng; Wang, Jianjun; Dong, Jun; Zhang, Ying; Yuan, Qiang; Wang, Yuancheng; Zhou, Wei; Peng, Zhitao; Wang, Fang; Hu, Dongxia; Zhu, Qihua; Zheng, Wanguo; Zhang, Xiaomin

    2014-12-01

    Multi-FM SSD and CPP was experimentally studied in high fluence and will be equipped on all the beams of SG-III laser facility. The output spectrum of the cascade phase modulators are stable and the residual amplitude modulation is small. FM-to-AM effect caused by free-space propagation after using smoothing by spectral dispersion is theoretically analyzed. Results indicate inserting a dispersion grating in places with larger beam aperture could alleviate the FM-to- AM effect, suggesting minimizing free-space propagation and adopting image relay. Experiments taken on SG-III laser facility indicate when the number of color cycles (Nc) adopts 1, imposing of SSD with 3.3 times diffraction limit (TDL) did not lead to pinhole closure in the spatial filters of the preamplifier and main amplifier with 30-TDL pinhole size. The nonuniformity of the focal spot using Multi-FM SSD and CPP drops to 0.26, comparing to 0.84 only using CPP. The experiments solve some key technical problems using SSD and CPP on SG-III laser facility, and provide a flexible platform for laser-plasma interaction experiments. Combined beam smoothing and polarization smoothing are also analyzed. Simulation results indicate through adjusting dispersion directions of one-dimensional SSD beams in a quad, two-dimensional SSD could be obtained. The near field and far field properties of beams using polarization smoothing were also studied, including birefringent wedge and polarization control plate (PCP). By using PCP, cylindrical vector beams could be obtained. New solutions will be provided to solve the LPI problem encountered in indirect drive laser fusion.

  13. Efficient channel-waveguide laser in Nd:GGG at 1.062 μm wavelength

    NASA Astrophysics Data System (ADS)

    Gerhardt, R.; Kleine-Börger, J.; Beilschmidt, L.; Frommeyer, M.; Dötsch, H.; Gather, B.

    1999-08-01

    Channel waveguide lasers in crystals of neodymium-doped gadolinium-gallium-garnet are realized. They are based on single-mode rib waveguides prepared by liquid phase epitaxy. By this growth technique the incorporation of certain impurities, which may cause severe quenching, is inevitable. The dominant quenching process could be identified and eliminated. Channel waveguides with extremely low losses, down to 0.25 dB/cm for both TE and TM modes, are fabricated by ion-beam etching. As a result, low thresholds of 5 mW and high slope efficiencies of 48% at the laser wavelength of 1.062 μm could be achieved when pumping at a wavelength of 807 nm.

  14. Trojan Horse Method and RIBs: The {sup 18}F(p,{alpha}){sup 15}O reaction at astrophysical energies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cherubini, S.; Gulino, M.; Rapisarda, G. G.

    2012-11-12

    The abundance of {sup 18}F in Nova explosions is an important issue for the understanding of this astrophysical phenomenon. For this reason it is necessary to study the nuclear reactions that produce or destroy this isotope in novae. Among these latter processes, the {sup 18}F(p,{alpha}){sup 15}O is one of the main {sup 18}F destruction channels. We report here on the preliminary results of the first experiment that applies the Trojan Horse Method to a Radioactive Ion Beam induced reaction. The experiment was performed using the CRIB apparatus of the Center for Nuclear Study of The Tokyo University.

  15. Physics Goals for the Planned Next Linear Collider Engineering Test Facility

    NASA Astrophysics Data System (ADS)

    Raubenheimer, T. O.

    2001-10-01

    The Next Linear Collider (NLC) Collaboration is planning to construct an Engineering Test Facility (ETF) at Fermilab. As presently envisioned, the ETF would comprise a fundamental unit of the NLC main linac to include X-band klystrons and modulators, a delay-line power-distribution system (DLDS), and NLC accelerating structures that serve as loads. The principal purpose of the ETF is to validate stable operation of the power-distribution system, first without beam, then with a beam having the NLC pulse structure. This paper concerns the possibility of configuring and using the ETF to accelerate beam with an NLC pulse structure, as well as of doing experiments to measure beam-induced wakefields in the rf structures and their influence back on the beam.

  16. Feasibility study for a biomedical experimental facility based on LEIR at CERN.

    PubMed

    Abler, Daniel; Garonna, Adriano; Carli, Christian; Dosanjh, Manjit; Peach, Ken

    2013-07-01

    In light of the recent European developments in ion beam therapy, there is a strong interest from the biomedical research community to have more access to clinically relevant beams. Beamtime for pre-clinical studies is currently very limited and a new dedicated facility would allow extensive research into the radiobiological mechanisms of ion beam radiation and the development of more refined techniques of dosimetry and imaging. This basic research would support the current clinical efforts of the new treatment centres in Europe (for example HIT, CNAO and MedAustron). This paper presents first investigations on the feasibility of an experimental biomedical facility based on the CERN Low Energy Ion Ring LEIR accelerator. Such a new facility could provide beams of light ions (from protons to neon ions) in a collaborative and cost-effective way, since it would rely partly on CERN's competences and infrastructure. The main technical challenges linked to the implementation of a slow extraction scheme for LEIR and to the design of the experimental beamlines are described and first solutions presented. These include introducing new extraction septa into one of the straight sections of the synchrotron, changing the power supply configuration of the magnets, and designing a new horizontal beamline suitable for clinical beam energies, and a low-energy vertical beamline for particular radiobiological experiments.

  17. Feasibility study for a biomedical experimental facility based on LEIR at CERN

    PubMed Central

    Abler, Daniel; Garonna, Adriano; Carli, Christian; Dosanjh, Manjit; Peach, Ken

    2013-01-01

    In light of the recent European developments in ion beam therapy, there is a strong interest from the biomedical research community to have more access to clinically relevant beams. Beamtime for pre-clinical studies is currently very limited and a new dedicated facility would allow extensive research into the radiobiological mechanisms of ion beam radiation and the development of more refined techniques of dosimetry and imaging. This basic research would support the current clinical efforts of the new treatment centres in Europe (for example HIT, CNAO and MedAustron). This paper presents first investigations on the feasibility of an experimental biomedical facility based on the CERN Low Energy Ion Ring LEIR accelerator. Such a new facility could provide beams of light ions (from protons to neon ions) in a collaborative and cost-effective way, since it would rely partly on CERN's competences and infrastructure. The main technical challenges linked to the implementation of a slow extraction scheme for LEIR and to the design of the experimental beamlines are described and first solutions presented. These include introducing new extraction septa into one of the straight sections of the synchrotron, changing the power supply configuration of the magnets, and designing a new horizontal beamline suitable for clinical beam energies, and a low-energy vertical beamline for particular radiobiological experiments. PMID:23824122

  18. The control system of the multi-strip ionization chamber for the HIMM

    NASA Astrophysics Data System (ADS)

    Li, Min; Yuan, Y. J.; Mao, R. S.; Xu, Z. G.; Li, Peng; Zhao, T. C.; Zhao, Z. L.; Zhang, Nong

    2015-03-01

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer-consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.

  19. An external milli-beam for archaeometric applications on the AGLAE IBA facility of the Louvre museum

    NASA Astrophysics Data System (ADS)

    Calligaro, T.; Dran, J.-C.; Hamon, H.; Moignard, B.; Salomon, J.

    1998-03-01

    External beam lines have been built on numerous IBA facilities for the analysis of works of art to avoid sampling and vacuum potentially detrimental to the integrity of such precious objects. On the other hand, growing interest lies on microprobe systems which provide a high lateral resolution but which usually work under vacuum. Until recently, the AGLAE facility was equipped with separate external beam and microprobe lines. The need of a better spatial resolution in the external beam mode has led us to combine them into a single system which exhibits numerous advantages and allows the analysis of small heterogeneities like inclusions in gemstones or tiny components of composite samples. The triplet of quadrupole lenses bought from Oxford is used to focus the beam. By using a 0.75 μm thick Al foil as the exit window, blowing a helium flow around the beam spot and reducing the window-sample distance below 3 mm, a beam size of about 30 μm can be reached. The experimental setup includes two Si(Li), a HPGe and a Si surface barrier detectors for the simultaneous implementation of PIXE, NRA and RBS. The full description of this device is given as well as a few applications to highlight its capability.

  20. Evolution of a beam dynamics model for the transport line in a proton therapy facility

    NASA Astrophysics Data System (ADS)

    Rizzoglio, V.; Adelmann, A.; Baumgarten, C.; Frey, M.; Gerbershagen, A.; Meer, D.; Schippers, J. M.

    2017-12-01

    During the conceptual design of an accelerator or beamline, first-order beam dynamics models are essential for studying beam properties. However, they can only produce approximate results. During commissioning, these approximate results are compared to measurements, which will rarely coincide if the model does not include the relevant physics. It is therefore essential that this linear model is extended to include higher-order effects. In this paper, the effects of particle-matter interaction have been included in the model of the transport lines in the proton therapy facility at the Paul Scherrer Institut (PSI) in Switzerland. The first-order models of these beamlines provide an approximated estimation of beam size, energy loss and transmission. To improve the performance of the facility, a more precise model was required and has been developed with opal (Object Oriented Parallel Accelerator Library), a multiparticle open source beam dynamics code. In opal, the Monte Carlo simulations of Coulomb scattering and energy loss are performed seamless with the particle tracking. Beside the linear optics, the influence of the passive elements (e.g., degrader, collimators, scattering foils, and air gaps) on the beam emittance and energy spread can be analyzed in the new model. This allows for a significantly improved precision in the prediction of beam transmission and beam properties. The accuracy of the opal model has been confirmed by numerous measurements.

  1. Beam-Plasma Interaction Experiments on the Princeton Advanced Test Stand

    NASA Astrophysics Data System (ADS)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I. D.; Davidson, R. C.

    2011-10-01

    The Princeton Advanced Test Stand (PATS) is a compact experimental facility for studying the fundamental physics of intense beam-plasma interactions relevant to the Neutralized Drift Compression Experiment - II (NDCX-II). The PATS facility consists of a 100 keV ion beam source mounted on a six-foot-long vacuum chamber with numerous ports for diagnostic access. A 100 keV Ar+ beam is launched into a volumetric plasma, which is produced by a ferroelectric plasma source (FEPS). Beam diagnostics upstream and downstream of the FEPS allow for detailed studies of the effects that the plasma has on the beam. This setup is designed for studying the dependence of charge and current neutralization and beam emittance growth on the beam and plasma parameters. This work reports initial measurements of beam quality produced by the extraction electrodes that were recently installed on the PATS device. The transverse beam phase space is measured with double-slit emittance scanners, and the experimental results are compared to WARP simulations of the extraction system. This research is supported by the U.S. Department of Energy.

  2. Shielding and Radiation Protection in Ion Beam Therapy Facilities

    NASA Astrophysics Data System (ADS)

    Wroe, Andrew J.; Rightnar, Steven

    Radiation protection is a key aspect of any radiotherapy (RT) department and is made even more complex in ion beam therapy (IBT) by the large facility size, secondary particle spectra and intricate installation of these centers. In IBT, large and complex radiation producing devices are used and made available to the public for treatment. It is thus the responsibility of the facility to put in place measures to protect not only the patient but also the general public, occupationally and nonoccupationally exposed personnel working within the facility, and electronics installed within the department to ensure maximum safety while delivering maximum up-time.

  3. Method and apparatus for monitoring the thickness of a coal rib during rib formation

    DOEpatents

    Mowrey, Gary L.; Ganoe, Carl W.; Monaghan, William D.

    1996-01-01

    Apparatus for monitoring the position of a mining machine cutting a new entry in a coal seam relative to an adjacent, previously cut entry to determine the distance between a near face of the adjacent previously cut entry and a new face adjacent thereto of a new entry being cut by the mining machine which together define the thickness of a coal rib being formed between the new entry and the adjacent previously cut entry during the new entry-cutting operation. The monitoring apparatus; includes a transmit antenna mounted on the mining machine and spaced inwardly from the new face of the coal rib for transmitting radio energy towards the coal rib so that one portion of the radio energy is reflected by the new face which is defined at an air-coal interface between the new entry and the coal rib and another portion of the radio energy is reflected by the near face of the coal rib which is defined at an air-coal interface between the coal rib and the adjacent previously cut entry. A receive antenna mounted on the mining machine and spaced inwardly of the new face of the coal rib receives the one portion of the radio energy reflected by the new face and also receives the another portion of the radio energy reflected by the near face. A processor determines a first elapsed time period equal to the time required for the one portion of the radio energy reflected by the new face to travel between the transmit antenna and the receive antenna and also determines a second elapsed time period equal to the time required for the another portion of the radio energy reflected by the near face to travel between the transmit antenna and the receive antenna and thereafter calculates the thickness of the coal rib being formed as a function of the difference between the first and second elapsed time periods.

  4. Rib fractures under anterior-posterior dynamic loads: experimental and finite-element study.

    PubMed

    Li, Zuoping; Kindig, Matthew W; Kerrigan, Jason R; Untaroiu, Costin D; Subit, Damien; Crandall, Jeff R; Kent, Richard W

    2010-01-19

    The purpose of this study was to investigate whether using a finite-element (FE) mesh composed entirely of hexahedral elements to model cortical and trabecular bone (all-hex model) would provide more accurate simulations than those with variable thickness shell elements for cortical bone and hexahedral elements for trabecular bone (hex-shell model) in the modeling human ribs. First, quasi-static non-injurious and dynamic injurious experiments were performed using the second, fourth, and tenth human thoracic ribs to record the structural behavior and fracture tolerance of individual ribs under anterior-posterior bending loads. Then, all-hex and hex-shell FE models for the three ribs were developed using an octree-based and multi-block hex meshing approach, respectively. Material properties of cortical bone were optimized using dynamic experimental data and the hex-shell model of the fourth rib and trabecular bone properties were taken from the literature. Overall, the reaction force-displacement relationship predicted by both all-hex and hex-shell models with nodes in the offset middle-cortical surfaces compared well with those measured experimentally for all the three ribs. With the exception of fracture locations, the predictions from all-hex and offset hex-shell models of the second and fourth ribs agreed better with experimental data than those from the tenth rib models in terms of reaction force at fracture (difference <15.4%), ultimate failure displacement and time (difference <7.3%), and cortical bone strains. The hex-shell models with shell nodes in outer cortical surfaces increased static reaction forces up to 16.6%, compared to offset hex-shell models. These results indicated that both all-hex and hex-shell modeling strategies were applicable for simulating rib responses and bone fractures for the loading conditions considered, but coarse hex-shell models with constant or variable shell thickness were more computationally efficient and therefore preferred. Copyright 2009 Elsevier Ltd. All rights reserved.

  5. New x-ray parallel beam facility XPBF 2.0 for the characterization of silicon pore optics

    NASA Astrophysics Data System (ADS)

    Krumrey, Michael; Müller, Peter; Cibik, Levent; Collon, Max; Barrière, Nicolas; Vacanti, Giuseppe; Bavdaz, Marcos; Wille, Eric

    2016-07-01

    A new X-ray parallel beam facility (XPBF 2.0) has been installed in the laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY II in Berlin to characterize silicon pore optics (SPOs) for the future X-ray observatory ATHENA. As the existing XPBF which is operated since 2005, the new beamline provides a pencil beam of very low divergence, a vacuum chamber with a hexapod system for accurate positioning of the SPO to be investigated, and a vertically movable CCD-based camera system to register the direct and the reflected beam. In contrast to the existing beamline, a multilayer-coated toroidal mirror is used for beam monochromatization at 1.6 keV and collimation, enabling the use of beam sizes between about 100 μm and at least 5 mm. Thus the quality of individual pores as well as the focusing properties of large groups of pores can be investigated. The new beamline also features increased travel ranges for the hexapod to cope with larger SPOs and a sample to detector distance of 12 m corresponding to the envisaged focal length of ATHENA.

  6. Radiation effects program

    NASA Astrophysics Data System (ADS)

    1985-09-01

    No existing LINAC Based Beam Heating facility comes within a factor of ten of the needs of a high heating rate thermodynamic properties research facility. The facility could be built at the Naval Research Lab. for a cost in the neighborhood of 2 million dollars. The 10 MeV electron beam would not produce any serious radioactivity but would provide unprecedented beam power for such other applications as food processing, sewer treatment, materials curing, radiation hardness assurance, etc. One can always achieve lower current densities by scattering the beam and moving the device under test further away from the scatterer. In this case one must rely on the TLD readings to indicate the dose rate at the point of interest. For general utility with the beam covering about four TLD's fairly evenly one can claim that the NRL LINAC can produce a maximum dose rate of about 6 x 10 to the 10th power rads (Si) per second for a pulse length of 1.5 microseconds, and about 1.4 x 10 to the 11th power rads (Si) per second in a 50 nanosecond pulse. In both cases the beam area is about 0.4 square centimeters.

  7. Concepts for the magnetic design of the MITICA neutral beam test facility ion accelerator.

    PubMed

    Chitarin, G; Agostinetti, P; Marconato, N; Marcuzzi, D; Sartori, E; Serianni, G; Sonato, P

    2012-02-01

    The megavolt ITER injector concept advancement neutral injector test facility will be constituted by a RF-driven negative ion source and by an electrostatic Accelerator, designed to produce a negative Ion with a specific energy up to 1 MeV. The beam is then neutralized in order to obtain a focused 17 MW neutral beam. The magnetic configuration inside the accelerator is of crucial importance for the achievement of a good beam efficiency, with the early deflection of the co-extracted and stripped electrons, and also of the required beam optic quality, with the correction of undesired ion beamlet deflections. Several alternative magnetic design concepts have been considered, comparing in detail the magnetic and beam optics simulation results, evidencing the advantages and drawbacks of each solution both from the physics and engineering point of view.

  8. Multiple Rib Nonunion: Open Reduction and Internal Fixation and Iliac Crest Bone Graft Aspirate.

    PubMed

    Kaplan, Daniel J; Begly, John; Tejwani, Nirmal

    2017-08-01

    Rib fractures are a common chest injury that can typically be treated nonoperatively. However, a percentage of these will go on to nonunion, either because of unique characteristics of the fracture itself or because of a variety of poor healing factors of the host. If a patient has continued symptomology beyond 3 months, surgeons may consider operative management. Although isolated resection of fibrous scar tissue from the nonunion site may be sufficient in some cases, it may also be necessary to provide additional structural integrity to the rib depending on the extent of the fracture pattern and resection. This goal can be achieved operatively with rib plating and bone grafting to promote healing. This video demonstrates the use of plating in the treatment of rib nonunion. It begins with relevant background information on rib fractures and nonunions, then details the approach, open reduction and internal fixation of 3 ribs using plates and bone graft aspirate. Pearls and pitfalls are included during the surgical technique aspect of the video to both help guide surgeons new to the procedure and provide potentially advantageous technical details to more experienced surgeons.

  9. Chest wall stabilization in trauma patients: why, when, and how?

    PubMed Central

    White, Thomas W.

    2018-01-01

    Blunt trauma to the chest wall and rib fractures are remarkably frequent and are the basis of considerable morbidity and possible mortality. Surgical remedies for highly displaced rib fractures, especially in cases of flail chest, have been undertaken intermittently for more than 50 years. Rib-specific plating systems have started to be used in the last 10 years. These have ushered in the modern era of rib repair with chest wall stabilization (CWS) techniques that are safer, easier to perform, and more efficient. Recent consensus statements have sought to define the indications and contraindications, as well as the when, the how, and the technical details of CWS. Repair should be considered for patients who have three or more displaced rib fractures or a flail chest, whether or not mechanical ventilation is required. Additional candidates include patients who fail non-operative management irrespective of fracture pattern and those with rib fractures who need thoracic procedures for other reasons. Traditionally, unstable spine fracture and severe traumatic brain injury are definite contraindications. Pulmonary contusion’s role in the decision to perform CWS remains controversial. A range of rib-specific plating systems are now commercially available. PMID:29744222

  10. The respective effect of under-rib convection and pressure drop of flow fields on the performance of PEM fuel cells.

    PubMed

    Wang, Chao; Zhang, Qinglei; Shen, Shuiyun; Yan, Xiaohui; Zhu, Fengjuan; Cheng, Xiaojing; Zhang, Junliang

    2017-03-02

    The flow field configuration plays an important role on the performance of proton exchange membrane fuel cells (PEMFCs). For instance, channel/rib width and total channel cross-sectional area determine the under-rib convection and pressure drop respectively, both of which directly influence the water removal, in turn affecting the oxygen supply and cathodic oxygen reduction reaction. In this study, effects of under-rib convection and pressure drop on cell performance are investigated experimentally and numerically by adjusting the channel/rib width and channel cross-sectional area of flow fields. The results show that the performance differences with various flow field configurations mainly derive from the oxygen transport resistance which is determined by the water accumulation degree, and the cell performance would benefit from the narrower channels and smaller cross sections. It reveals that at low current densities when water starts to accumulate in GDL at under-rib regions, the under-rib convection plays a more important role in water removal than pressure drop does; in contrast, at high current densities when water starts to accumulate in channels, the pressure drop dominates the water removal to facilitate the oxygen transport to the catalyst layer.

  11. The respective effect of under-rib convection and pressure drop of flow fields on the performance of PEM fuel cells

    NASA Astrophysics Data System (ADS)

    Wang, Chao; Zhang, Qinglei; Shen, Shuiyun; Yan, Xiaohui; Zhu, Fengjuan; Cheng, Xiaojing; Zhang, Junliang

    2017-03-01

    The flow field configuration plays an important role on the performance of proton exchange membrane fuel cells (PEMFCs). For instance, channel/rib width and total channel cross-sectional area determine the under-rib convection and pressure drop respectively, both of which directly influence the water removal, in turn affecting the oxygen supply and cathodic oxygen reduction reaction. In this study, effects of under-rib convection and pressure drop on cell performance are investigated experimentally and numerically by adjusting the channel/rib width and channel cross-sectional area of flow fields. The results show that the performance differences with various flow field configurations mainly derive from the oxygen transport resistance which is determined by the water accumulation degree, and the cell performance would benefit from the narrower channels and smaller cross sections. It reveals that at low current densities when water starts to accumulate in GDL at under-rib regions, the under-rib convection plays a more important role in water removal than pressure drop does; in contrast, at high current densities when water starts to accumulate in channels, the pressure drop dominates the water removal to facilitate the oxygen transport to the catalyst layer.

  12. Regional Variation in the Structural Response and Geometrical Properties of Human Ribs

    PubMed Central

    Cormier, Joseph M.; Stitzel, Joel D.; Duma, Stefan M.; Matsuoka, Fumio

    2005-01-01

    By incorporating material and geometrical properties into a model of the human thorax one can develop an injury criterion that is a function of stress and strain of the material and not a function of the global response of the thorax. Previous research on the mechanical properties of ribs has focused on a limited set of specific ribs. For this study a total of 52 rib specimens were removed from four cadaver subjects. Variation in peak moment by thoracic region was significant (p < 0.01) with average values of 2, 2.9 and 3.9 N-m for the anterior, lateral and posterior regions respectively. Two geometrical properties, radius of gyration and distance from the neutral axis, showed significant variation by region (p < 0.0001) as well as by rib level (p = < 0.01, 0.05). The results of this study can be used to update current models of the human thorax to account for the variation in strength and geometrical properties throughout the rib cage. Accounting for the variation in rib properties by region will improve injury predictive measures and, therefore, the ability to design systems to prevent thoracic injury. PMID:16179146

  13. Design and fabrication of inverted rib waveguide Bragg grating

    NASA Astrophysics Data System (ADS)

    Huang, Cheng-Sheng; Wang, Wei-Chih

    2009-03-01

    A polymeric SU8 rib waveguide Bragg grating filterfabricated using reactive ion etching (RIE) and solvent assisted microcontact molding (SAMIM) is presented. SAMIM is one kind of soft lithography. The technique is unique in which that a composite hPDMS/PDMS stamp was used to transfer the grating pattern onto an inverted SU8 rib waveguide system. The composite grating stamp can be used repeatedly several times with degradation. Using this stamp and inverter rib waveguide structure, the Bragg grating filter fabrication can be significantly simplified.

  14. Performance of the 2 × 4-cell superconducting linac module for the THz-FEL facility

    NASA Astrophysics Data System (ADS)

    Kui, Zhou; Chenglong, Lao; Dai, Wu; Xing, Luo; Jianxin, Wang; Dexin, Xiao; Lijun, Shan; Tianhui, He; Xuming, Shen; Sifen, Lin; Linde, Yang; Hanbin, Wang; Xingfan, Yang; Ming, Li; Xiangyang, Lu

    2018-07-01

    A high average power THz radiation facility has been developed by the China Academy of Engineering Physics. It is the first CW THz user facility based on superconducting accelerator technology in China. The superconducting linac module, which contains two 4-cell 1.3 GHz TESLA-like superconducting radio frequency cavities, is a major component of this facility. The expected electron energy gain is 6-8 MeV with a field gradient of 8-10 MV/m. The design and fabrication of the linac module is complete. This paper discusses its assembly and results from cyromodule tests and beam commissioning. At 2 K, the cryomodule works smoothly and stably. Both cavities have achieved effective field gradients of 10 MV/m. In beam loading experiments, 8 MeV, 5 mA electron beams with an energy spread less than 0.2% have been produced, which satisfies our requirements.

  15. CT measured normative cartilage growth in children requiring costochondral grafting.

    PubMed

    Andreoli, Steven M; Mills, Jared C; Kilpatrick, Lauren A; White, David R; Patel, Krishna G

    2013-12-01

    Careful operative timing is required for children undergoing microtia repair using autologous costochondral grafting. This operation is performed as early as age 6 in efforts to treat children before school matriculation while allowing for sufficient rib growth. There remains a paucity of data regarding cartilaginous growth of the ribs and synchondrosis routinely harvested during microtia repair. This study employs CT imaging to generate normative costochondral growth characteristics in children. A population-based study was performed. Tertiary care children's hospital. Chest CTs were reviewed in 360 children ages 3 to 20 years. Measurements included: length of ribs 6, 7, and 8 and the height and width of the synchondrosis between ribs 6 and 7. Growth charts are presented for gender and laterality. At age 6: ribs 6, 7, and 8 measure 5.96 ± 0.69, 7.79 ± 0.84, and 6.33 ± 1.01 cm, respectively. In adulthood the mean length of ribs 6, 7, and 8 are 8.29 ± 1.00, 11.10 ± 1.19, and 8.95 ± 1.99 cm, respectively. The vertical height of the synchondrosis at years 6 and 20 are 2.42 ± 0.39 and 3.59 ± 0.53 cm, respectively. Ribs 6, 7, and 8 as well as the synchondrosis grow in a nearly linear fashion. Cartilaginous growth of ribs 6 to 8 during early childhood is nearly linear. Synchondrosis height approaches adult auricle width at 8 years. Rib size is consistently larger in males and on the left side. These data are useful for the pediatric otolaryngologist and facial plastics and reconstructive surgeon performing microtia surgery.

  16. Lower thoracic rib stress fractures in baseball pitchers.

    PubMed

    Gerrie, Brayden J; Harris, Joshua D; Lintner, David M; McCulloch, Patrick C

    2016-01-01

    Stress fractures of the first rib on the dominant throwing side are well-described in baseball pitchers; however, lower thoracic rib fractures are not commonly recognized. While common in other sports such as rowing, there is scant literature on these injuries in baseball. Intercostal muscle strains are commonly diagnosed in baseball pitchers and have a nearly identical presentation but also a highly variable healing time. The diagnosis of a rib stress fracture can predict a more protracted recovery. This case series presents two collegiate baseball pitchers on one team during the same season who were originally diagnosed with intercostal muscle strains, which following magnetic resonance imaging (MRI) were found to have actually sustained lower thoracic rib stress fractures. The first sustained a stress fracture of the posterior aspect of the right 8th rib on the dominant arm side, while the second presented with a left-sided 10th rib stress fracture on the nondominant arm side. In both cases, MRI was used to visualize the fractures as plain radiographs are insensitive and commonly negative early in patient presentation. Patients were treated with activity modification, and symptomatic management for 4-6 weeks with a graduated return to throwing and competition by 8-10 weeks. The repetitive high stresses incurred by pitching may cause either dominant or nondominant rib stress fractures and this should be included in the differential diagnosis of thoracic injuries in throwers. It is especially important that athletic trainers and team physicians consider this diagnosis, as rib fractures may have a protracted course and delayed return to play. Additionally, using the appropriate imaging techniques to establish an accurate diagnosis can help inform return-to-play decisions, which have important practical applications in baseball, such as roster management and eligibility.

  17. The crystal structure of the bifunctional deaminase/reductase RibD of the riboflavin biosynthetic pathway in Escherichia coli: implications for the reductive mechanism.

    PubMed

    Stenmark, Pål; Moche, Martin; Gurmu, Daniel; Nordlund, Pär

    2007-10-12

    We have determined the crystal structure of the bi-functional deaminase/reductase enzyme from Escherichia coli (EcRibD) that catalyzes two consecutive reactions during riboflavin biosynthesis. The polypeptide chain of EcRibD is folded into two domains where the 3D structure of the N-terminal domain (1-145) is similar to cytosine deaminase and the C-terminal domain (146-367) is similar to dihydrofolate reductase. We showed that EcRibD is dimeric and compared our structure to tetrameric RibG, an ortholog from Bacillus subtilis (BsRibG). We have also determined the structure of EcRibD in two binary complexes with the oxidized cofactor (NADP(+)) and with the substrate analogue ribose-5-phosphate (RP5) and superposed these two in order to mimic the ternary complex. Based on this superposition we propose that the invariant Asp200 initiates the reductive reaction by abstracting a proton from the bound substrate and that the pro-R proton from C4 of the cofactor is transferred to C1 of the substrate. A highly flexible loop is found in the reductase active site (159-173) that appears to control cofactor and substrate binding to the reductase active site and was therefore compared to the corresponding Met20 loop of E. coli dihydrofolate reductase (EcDHFR). Lys152, identified by comparing substrate analogue (RP5) coordination in the reductase active site of EcRibD with the homologous reductase from Methanocaldococcus jannaschii (MjaRED), is invariant among bacterial RibD enzymes and could contribute to the various pathways taken during riboflavin biosynthesis in bacteria and yeast.

  18. Local heat/mass transfer and pressure drop in a two-pass rib-roughened channel for turbine airfoil cooling

    NASA Technical Reports Server (NTRS)

    Han, J. C.; Chandra, P. R.

    1987-01-01

    The heat transfer characteristics of turbulent air flow in a multipass channel were studied via the naphthalene sublimation technique. The naphthalene-coated test section, consisting of two straight, square channels joined by a 180 deg turn, resembled the internal cooling passages of gas turbine airfoils. The top and bottom surfaces of the test channel were roughened by rib turbulators. The rib height-to-hydraulic diameter ratio (e/D) were 0.063 and 0.094, and the rib pitch-to-height ratio (P/e) were 10 and 20. The local heat/mass transfer coefficients on the roughened top wall and on the smooth divider and side walls of the test channel were determined for three Reynolds numbers of 15, 30, and 60, thousand, and for three angles of attack (alpha) of 90, 60, and 45 deg. Results showed that the local Sherwood numbers on the ribbed walls were 1.5 to 6.5 times those for a fully developed flow in a smooth square duct. The average ribbed-wall Sherwood numbers were 2.5 to 3.5 times higher than the fully developed values, depending on the rib angle of attack and the Reynolds number. The results also indicated that, before the turn, the heat/mass transfer coefficients in the cases of alpha = 60 and 45 deg were higher than those in the case of alpha=90 deg. However, after the turn, the heat/mass transfer coefficients in the oblique-rib cases were lower than those in the transverse rib case. Correlations for the average Sherwood number ratios for individual channel surfaces and for the overall Sherwood number ratios are reported. Correlations for the fully developed friction factors and for the loss coefficients are also provided.

  19. Measurements of the pulmonary vasculature on thoracic radiographs in healthy dogs compared to dogs with mitral regurgitation.

    PubMed

    Oui, Heejin; Oh, Juyeon; Keh, Seoyeon; Lee, Gahyun; Jeon, Sunghoon; Kim, Hyunwook; Yoon, Junghee; Choi, Jihye

    2015-01-01

    This study reassessed the previously reported radiographic method of comparing pulmonary vessels versus rib diameter for differentiating healthy dogs and dogs with mitral regurgitation. The width of the right cranial pulmonary artery and vein at the fourth rib level, right caudal pulmonary artery and vein at the ninth rib level, and the diameters of the fourth rib and ninth rib were measured in prospectively recruited healthy dogs (n = 40) and retrospectively recruited dogs with mitral regurgitation (n = 58). In healthy dogs, the pulmonary arteries and accompanying veins were similar in size. The cranial lobar vessels were smaller than the fourth rib. However, 67.5% of right caudal pulmonary artery diameters and 65% of vein diameters were larger than the ninth rib in healthy dogs. The right caudal pulmonary vein diameter in dogs with mitral regurgitation, particularly those within moderate and severe grades, was significantly larger than that in healthy dogs (P < 0.001). The comparative method used to detect enlargement of the right caudal pulmonary vein relative to the accompanying pulmonary artery had the highest sensitivity (80.2%) and specificity (82.5%) for predicting mitral regurgitation. A cut-off of 1.22 when applying the ninth rib criterion had better specificity (73%) than the most used value ≤ 1 (89.7% sensitivity and 63.8% specificity), although it has less sensitivity (73%). We recommend using the accompanying pulmonary artery and 1.22 × the diameter of the ninth rib as a radiographic criterion for assessing the size of the right caudal pulmonary vein and differentiating healthy dogs from those with mitral regurgitation. © 2014 American College of Veterinary Radiology.

  20. Frequency of intrathoracic injuries in children younger than 3 years with rib fractures.

    PubMed

    Darling, Stephen E; Done, Stephen L; Friedman, Seth D; Feldman, Kenneth W

    2014-10-01

    Research documents that among children admitted to trauma intensive care units the number of rib fractures sustained indicates the child's likelihood of having and severity of intrathoracic injury. This has been misused in court to argue that children with multiple rib fractures who lack intrathoracic injury have abnormal bone fragility rather than inflicted injury. To determine frequency of intrathoracic injuries in children younger than 3 years with rib fractures in cases of child abuse and accidental trauma. We conducted a retrospective review of rib fractures caused by documented abuse or accidents from 2003 to 2010 in children treated at Seattle Children's Hospital and Harborview Medical Center. A senior pediatric radiologist and radiology fellow independently reviewed the imaging. Children with bone demineralization were excluded. Descriptive and simple comparative statistics were used. Seventy-two percent (47/65) of infants and toddlers with rib fractures were abused. Abused children had more rib fractures than accidentally injured children (5.55 vs. 3.11, P = 0.012). However intrathoracic injuries as a whole (55.6% vs. 12.8%, P < 0.001) and individual types of intrathoracic injuries were more common with accidents. Rates of other thoracic cage injuries did not differ substantially (27.8% accidents vs. 12.8% abuse, P = 0.064). Intracranial and intra-abdominal injuries and skull fractures were equally frequent, but other extrathoracic fractures were more common with abuse (70.2% vs. 16.7%, P < 0.001). Abused infants and toddlers have fewer intrathoracic injuries but more rib fractures than accidentally injured peers. This likely reflects different injury mechanics. Lack of intrathoracic injuries in abused children with rib fractures does not imply bone fragility.

  1. Number of Ribs Resected is Associated with Respiratory Complications Following Lobectomy with en bloc Chest Wall Resection.

    PubMed

    Geissen, Nicole M; Medairos, Robert; Davila, Edgar; Basu, Sanjib; Warren, William H; Chmielewski, Gary W; Liptay, Michael J; Arndt, Andrew T; Seder, Christopher W

    2016-08-01

    Pulmonary lobectomy with en bloc chest wall resection is a common strategy for treating lung cancers invading the chest wall. We hypothesized a direct relationship exists between number of ribs resected and postoperative respiratory complications. An institutional database was queried for patients with non-small cell lung cancer that underwent lobectomy with en bloc chest wall resection between 2003 and 2014. Propensity matching was used to identify a cohort of patients who underwent lobectomy via thoracotomy without chest wall resection. Patients were propensity matched on age, gender, smoking history, FEV1, and DLCO. The relationship between number of ribs resected and postoperative respiratory complications (bronchoscopy, re-intubation, pneumonia, or tracheostomy) was examined. Sixty-eight patients (34 chest wall resections; 34 without chest wall resection) were divided into 3 cohorts: cohort A = 0 ribs resected (n = 34), cohort B = 1-3 ribs resected (n = 24), and cohort C = 4-6 ribs resected (n = 10). Patient demographics were similar between cohorts. The 90-day mortality rate was 2.9 % (2/68) and did not vary between cohorts. On multivariate analysis, having 1-3 ribs resected (OR 19.29, 95 % CI (1.33, 280.72); p = 0.03), 4-6 ribs resected [OR 26.66, (1.48, 481.86); p = 0.03), and a lower DLCO (OR 0.91, (0.84, 0.99); p = 0.02) were associated with postoperative respiratory complications. In patients undergoing lobectomy with en bloc chest wall resection for non-small cell lung cancer, the number of ribs resected is directly associated with incidence of postoperative respiratory complications.

  2. An analytical study of the free and forced vibration response of a ribbed plate with free boundary conditions

    NASA Astrophysics Data System (ADS)

    Lin, Tian Ran; Zhang, Kai

    2018-05-01

    An analytical study to predict the vibration response of a ribbed plate with free boundary conditions is presented. The analytical solution was derived using a double cosine integral transform technique and then utilized to study the free and forced vibration of the ribbed plate, as well as the effect of the rib on the modal response of the uniform plate. It is shown that in addition to the three zero-frequency rigid body modes of the plate, the vibration modes of the uniform plate can be classified into four mode groups according to the symmetric properties of the plate with respect to the two orthogonal middle lines parallel to the plate edges. The four mode groups correspond to a double symmetric group, a double anti-symmetric group and two symmetric/anti-symmetric groups. Whilst the inclusion of the rib to the plate is shown to cause distortion to the distribution of vibration modes, most modes can still be traced back to the original modes of the uniform plate. Both the mass and stiffness of the rib are shown to affect the modal vibration of the uniform plate, whereby a dominant effect from the rib mass leads to a decrease in the modal frequency of the plate, whereas a dominant effect from the rib stiffness leads to an increase in plate modal frequency. When the stiffened rib behaves as an effective boundary to the plate vibration, an original plate mode becomes a pair of degenerate modes, whereby one mode has a higher frequency and the other mode has a lower frequency than that of the original mode.

  3. Parasitic production of slow RI-beam from a projectile fragment separator by ion guide Laser Ion Source (PALIS)

    NASA Astrophysics Data System (ADS)

    Sonoda, Tetsu

    2009-10-01

    The projectile fragment separator BigRIPS of RIBF at RIKEN provides a wide variety of short-lived radioactive isotope (RI) ions without restrictions on their lifetime or chemical properties. A universal slow RI-beam facility (SLOWRI) to decelerate the beams from BigRIPS using an RF-carpet ion guide has been proposed as a principal facility of RIBF. However, beam time at such a modern accelerator facility is always limited and operational costs are high. We therefore propose an additional scheme as a complementary option to SLOWRI to drastically enhance the usability of such an expensive facility. In BigRIPS, a single primary beam produces thousands of isotopes but only one isotope is used for an experiment while the other >99.99% of isotopes are simply dumped in the slits or elsewhere in the fragment separator. We plan to locate a compact gas cell with 1 bar Ar at the slits. The thermalized ions in the cell will be quickly neutralized and transported to the exit by gas flow and resonantly re-ionized by lasers. Such low energy RI-beams will always be provided without any restriction to the main experiment. It will allow us to run parasitic experiments for precision atomic or decay spectroscopy, mass measurements. Furthermore, the resonance ionization in the cell itself can be used for high-sensitive laser spectroscopy, which will expand our knowledge of the ground state property of unstable nuclei.

  4. Astrophysics at RIA (ARIA) Working Group

    NASA Astrophysics Data System (ADS)

    Smith, Michael S.; Schatz, Hendrik; Timmes, Frank X.; Wiescher, Michael; Greife, Uwe

    2006-07-01

    The Astrophysics at RIA (ARIA) Working Group has been established to develop and promote the nuclear astrophysics research anticipated at the Rare Isotope Accelerator (RIA). RIA is a proposed next-generation nuclear science facility in the U.S. that will enable significant progress in studies of core collapse supernovae, thermonuclear supernovae, X-ray bursts, novae, and other astrophysical sites. Many of the topics addressed by the Working Group are relevant for the RIKEN RI Beam Factory, the planned GSI-Fair facility, and other advanced radioactive beam facilities.

  5. Phrenic Arterial Injury Presenting as Delayed Hemothorax Complicating Simple Rib Fracture.

    PubMed

    Ahn, Hong Joon; Lee, Jun Wan; Kim, Kun Dong; You, In Sool

    2016-04-01

    Delayed hemothorax after blunt torso injury is rare, but might be associated with significant morbidity and mortality. We present a case of delayed hemothorax bleeding from phrenic artery injury in a 24-year-old woman. The patient suffered from multiple rib fractures on the right side, a right hemopneumothorax, thoracic vertebral injury and a pelvic bone fracture after a fall from a fourth floor window. Delayed hemothorax associated with phrenic artery bleeding, caused by a stab injury from a fractured rib segment, was treated successfully by a minimally invasive thoracoscopic surgery. Here, we have shown that fracture of a lower rib or ribs might be accompanied by delayed massive hemothorax that can be rapidly identified and promptly managed by thoracoscopic means.

  6. Phrenic Arterial Injury Presenting as Delayed Hemothorax Complicating Simple Rib Fracture

    PubMed Central

    2016-01-01

    Delayed hemothorax after blunt torso injury is rare, but might be associated with significant morbidity and mortality. We present a case of delayed hemothorax bleeding from phrenic artery injury in a 24-year-old woman. The patient suffered from multiple rib fractures on the right side, a right hemopneumothorax, thoracic vertebral injury and a pelvic bone fracture after a fall from a fourth floor window. Delayed hemothorax associated with phrenic artery bleeding, caused by a stab injury from a fractured rib segment, was treated successfully by a minimally invasive thoracoscopic surgery. Here, we have shown that fracture of a lower rib or ribs might be accompanied by delayed massive hemothorax that can be rapidly identified and promptly managed by thoracoscopic means. PMID:27051252

  7. FOCUS SPLITTING ASSOCIATED WITH PROPAGATION OF FOCUSED ULTRASOUND THROUGH THE RIB CAGE

    PubMed Central

    Khokhlova, V. A.; Bobkova, S. M.; Gavrilov, L. R.

    2011-01-01

    The effect of focus splitting after propagation of focused ultrasound through a rib cage is investigated theoretically. It is shown that the mechanism of this effect is caused by the interference of waves from two or more spatially separated sources, such as intercostal spaces. Analytical estimates of the parameters of splitting are obtained, i.e., the number of foci, their amplitudes, diameter, and the distance between them, depending on the transducer parameters, as well as the dimensions of the rib cage and position of ribs relative to the radiator. Various configurations of the relative positioning of ribs and radiator are considered; it is shown which of them are the most effective for real surgical operations. PMID:21607120

  8. SU-E-T-590: Optimizing Magnetic Field Strengths with Matlab for An Ion-Optic System in Particle Therapy Consisting of Two Quadrupole Magnets for Subsequent Simulations with the Monte-Carlo Code FLUKA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumann, K; Weber, U; Simeonov, Y

    Purpose: Aim of this study was to optimize the magnetic field strengths of two quadrupole magnets in a particle therapy facility in order to obtain a beam quality suitable for spot beam scanning. Methods: The particle transport through an ion-optic system of a particle therapy facility consisting of the beam tube, two quadrupole magnets and a beam monitor system was calculated with the help of Matlab by using matrices that solve the equation of motion of a charged particle in a magnetic field and field-free region, respectively. The magnetic field strengths were optimized in order to obtain a circular andmore » thin beam spot at the iso-center of the therapy facility. These optimized field strengths were subsequently transferred to the Monte-Carlo code FLUKA and the transport of 80 MeV/u C12-ions through this ion-optic system was calculated by using a user-routine to implement magnetic fields. The fluence along the beam-axis and at the iso-center was evaluated. Results: The magnetic field strengths could be optimized by using Matlab and transferred to the Monte-Carlo code FLUKA. The implementation via a user-routine was successful. Analyzing the fluence-pattern along the beam-axis the characteristic focusing and de-focusing effects of the quadrupole magnets could be reproduced. Furthermore the beam spot at the iso-center was circular and significantly thinner compared to an unfocused beam. Conclusion: In this study a Matlab tool was developed to optimize magnetic field strengths for an ion-optic system consisting of two quadrupole magnets as part of a particle therapy facility. These magnetic field strengths could subsequently be transferred to and implemented in the Monte-Carlo code FLUKA to simulate the particle transport through this optimized ion-optic system.« less

  9. Vibroacoustic Model Validation for a Curved Honeycomb Composite Panel

    NASA Technical Reports Server (NTRS)

    Buehrle, Ralph D.; Robinson, Jay H.; Grosveld, Ferdinand W.

    2001-01-01

    Finite element and boundary element models are developed to investigate the vibroacoustic response of a curved honeycomb composite sidewall panel. Results from vibroacoustic tests conducted in the NASA Langley Structural Acoustic Loads and Transmission facility are used to validate the numerical predictions. The sidewall panel is constructed from a flexible honeycomb core sandwiched between carbon fiber reinforced composite laminate face sheets. This type of construction is being used in the development of an all-composite aircraft fuselage. In contrast to conventional rib-stiffened aircraft fuselage structures, the composite panel has nominally uniform thickness resulting in a uniform distribution of mass and stiffness. Due to differences in the mass and stiffness distribution, the noise transmission mechanisms for the composite panel are expected to be substantially different from those of a conventional rib-stiffened structure. The development of accurate vibroacoustic models will aide in the understanding of the dominant noise transmission mechanisms and enable optimization studies to be performed that will determine the most beneficial noise control treatments. Finite element and boundary element models of the sidewall panel are described. Vibroacoustic response predictions are presented for forced vibration input and the results are compared with experimental data.

  10. Folding retractable protective dome for space vehicle equipment

    NASA Technical Reports Server (NTRS)

    Clark, Paul R. (Inventor); Messinger, Ross H. (Inventor)

    2008-01-01

    A folding, retractable dome for protecting a feature, such as a docking mechanism, a hatch or other equipment at an exterior surface of a space vehicle, includes a plurality of arcuate ribs, each having opposite ends respectively pinioned at opposite sides of the feature at the surface of the vehicle for rotational movement about an axis of rotation extending through the opposite ends and through an arcuate path of revolution extending over the feature, and a flexible cover attached to each of the ribs such that, in a deployed configuration of the dome, in which adjacent ribs are rotated apart from each other at a maximum relative angle therebetween, the cover is stretched generally tangentially between the adjacent ribs to form a generally arcuate shield over the feature, and in a retracted position of the dome, in which adjacent ribs are rotated together at a minimum relative angle therebetween, the cover is collapsed to define folded pleats between the adjacent ribs.

  11. Differentiating the Causes of Spontaneous Rib Fracture After Breast Cancer.

    PubMed

    Harris, Susan R

    2016-12-01

    Spontaneous rib fracture after treatment for primary breast cancer is not uncommon. Although metastatic disease accounts for about 30% of spontaneous rib fractures and should constitute the first line of diagnostic investigation, other possible contributors include primary osteoporosis or secondary osteoporosis resulting from cancer treatments. Chemotherapy-induced menopause, aromatase inhibitors, radiation therapy, and long-term bisphosphonate use can all contribute to bone fragility, including spontaneous rib fractures in the latter 3. Drawing on recent breast cancer practice guidelines as well as population-based studies of fracture risk for women with a history of breast cancer and systematic reviews, this Perspective will provide an update on recent developments in understanding how to differentiate the possible reasons for non-traumatic rib fracture in women treated for breast cancer. In addition to describing the various possible causes of spontaneous rib fracture, the recommended medical and imaging procedures for differentiating among the potential causes will be presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Los Alamos National Laboratory Facility Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Ronald Owen

    2015-06-05

    This series of slides depicts the Los Alamos Neutron Science Center (LANSCE). The Center's 800-MeV linac produces H + and H - beams as well as beams of moderated (cold to 1 MeV) and unmoderated (0.1 to 600 MeV) neutrons. Experimental facilities and their capabilities and characteristics are outlined. Among these are LENZ, SPIDER, and DANCE.

  13. Fermilab Test Beam Facility Annual Report. FY 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brandt, A.

    2015-01-01

    Fermilab Test Beam Facility (FTBF) operations are summarized for FY 2014. It is one of a series of publications intended to gather information in one place. In this case, the information concerns the individual experiments that ran at FTBF. Each experiment section was prepared by the relevant authors, and was edited for inclusion in this summary.

  14. The national ignition facility: path to ignition in the laboratory

    NASA Astrophysics Data System (ADS)

    Moses, E. I.; Bonanno, R. E.; Haynam, C. A.; Kauffman, R. L.; MacGowan, B. J.; Patterson, R. W., Jr.; Sawicki, R. H.; van Wonterghem, B. M.

    2007-08-01

    The National Ignition Facility (NIF) is a 192-beam laser facility presently under construction at LLNL. When completed, NIF will be a 1.8-MJ, 500-TW ultraviolet laser system. Its missions are to obtain fusion ignition and to perform high energy density experiments in support of the US nuclear weapons stockpile. Four of the NIF beams have been commissioned to demonstrate laser performance and to commission the target area including target and beam alignment and laser timing. During this time, NIF demonstrated on a single-beam basis that it will meet its performance goals and demonstrated its precision and flexibility for pulse shaping, pointing, timing and beam conditioning. It also performed four important experiments for Inertial Confinement Fusion and High Energy Density Science. Presently, the project is installing production hardware to complete the project in 2009 with the goal to begin ignition experiments in 2010. An integrated plan has been developed including the NIF operations, user equipment such as diagnostics and cryogenic target capability, and experiments and calculations to meet this goal. This talk will provide NIF status, the plan to complete NIF, and the path to ignition.

  15. Determinants of rib motion in flail chest.

    PubMed

    Cappello, M; Legrand, A; De Troyer, A

    1999-03-01

    We have previously developed a canine model of isolated flail chest to assess the effects of this condition on the mechanics of breathing, and these studies have led to the conclusion that the respiratory displacement of the fractured ribs is primarily determined by the fall in pleural pressure (Delta Ppl) and the action of the parasternal intercostal muscles. The present studies were designed to test the validity of this conclusion. A flail was induced in six supine anesthetized animals by fracturing both dorsally and ventrally the second to fifth ribs on the right side of the chest, after which the phrenic nerve roots were bilaterally sectioned in the neck. Sectioning the phrenic nerves caused a 34% decrease in Delta Ppl, associated with a 39% increase in parasternal intercostal inspiratory EMG activity (p < 0.05), and resulted in a marked reduction in the inspiratory inward displacement of the ribs. In three animals, the inward rib displacement was even reversed into a small outward displacement. When the airway was then occluded at end-expiration to increase Delta Ppl during the subsequent inspiration, all animals again showed a clear-cut inward rib displacement. These observations therefore confirm that in dogs with flail chest, the inspiratory displacement of the fractured ribs is set by the balance between the force related to pleural pressure and that generated by the parasternal intercostals. These observations also point to the critical importance of the pattern of inspiratory muscle activation in determining the magnitude of rib cage paradox in such patients.

  16. Periods of vertebral column sensitivity to boric acid treatment in CD-1 mice in utero.

    PubMed

    Cherrington, Jana W; Chernoff, Neil

    2002-01-01

    Boric acid (BA) has many uses as an industrial compound and is widely distributed in the environment. BA has been shown to produce rib agenesis, a rare effect in laboratory animals. This study was conducted to determine if there is a period of sensitivity to this unusual effect. BA (500 or 750 mg/kg) was administered p.o. to pregnant CD-1 mice once daily on gestational days (GDs) 6-10. A reduction of 13th rib length occurred at both dose levels. BA 400mg/kg was also administered twice daily on GD 6, 7, 8, 9, or 10 or on GDs 6-8. A significant decrease in average fetal weight was observed in all treatment groups. Significant increases in the incidence of cervical ribs/ossifications resulted from treatments on GD 7 and GDs 6-8. Rib agenesis occurred with treatment on GD 8 and GDs 6-8. Reduced rib length, a decreased incidence of supernumerary ribs (SNR), and an increased incidence of fused and/or branched ribs occurred when dams were treated GDs 6-8. Doses of 750 mg/kg given twice on day 8 produced significant increases in several thoracic skeletal anomalies. Further studies of pathogenesis are necessary to determine the earliest perturbations and the processes that are affected. The sensitivity of embryos to treatment on GD 8 to rib agenesis suggests that BA is affecting early processes such as gastrulation and presomitic mesoderm formation and patterning in this area.

  17. ACR Appropriateness Criteria® rib fractures.

    PubMed

    Henry, Travis S; Kirsch, Jacobo; Kanne, Jeffrey P; Chung, Jonathan H; Donnelly, Edwin F; Ginsburg, Mark E; Heitkamp, Darel E; Kazerooni, Ella A; Ketai, Loren H; McComb, Barbara L; Parker, J Anthony; Ravenel, James G; Restrepo, Carlos Santiago; Saleh, Anthony G; Shah, Rakesh D; Steiner, Robert M; Suh, Robert D; Mohammed, Tan-Lucien H

    2014-11-01

    Rib fracture is the most common thoracic injury, present in 10% of all traumatic injuries and almost 40% of patients who sustain severe nonpenetrating trauma. Although rib fractures can produce significant morbidity, the diagnosis of associated complications (such as pneumothorax, hemothorax, pulmonary contusion, atelectasis, flail chest, cardiovascular injury, and injuries to solid and hollow abdominal organs) may have a more significant clinical impact. When isolated, rib fractures have a relatively low morbidity and mortality, and failure to detect isolated rib fractures does not necessarily alter patient management or outcome in uncomplicated cases. A standard posteroanterior chest radiograph should be the initial, and often the only, imaging test required in patients with suspected rib fracture after minor trauma. Detailed radiographs of the ribs rarely add additional information that would change treatment, and, although other imaging tests (eg, computed tomography, bone scan) have increased sensitivity for detection of rib fractures, there are little data to support their use. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 3 years by a multidisciplinary expert panel. The guideline development and review process include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.

  18. Potential Benefits of Rib Fracture Fixation in Patients with Flail Chest and Multiple Non-flail Rib Fractures.

    PubMed

    Qiu, Meiguang; Shi, Zhanjun; Xiao, Jun; Zhang, Xuming; Ling, Shishui; Ling, Hao

    2016-12-01

    The purpose of this study is to evaluate the potential benefits of rib fracture fixation in patients with flail chest and multiple non-flail rib fractures versus conventional treatment modalities. A retrospective reviewed study compared 86 cases which received surgical treatment between June 2009 and May 2013 to 76 cases which received conservative treatment between January 2006 and May 2009. The patients were divided into the flail chest ( n  = 38) and multiple non-flail rib fracture groups ( n  = 124). In the flail chest group, the mechanical ventilation time, ICU monitoring time, tracheostomies, thoracic deformity, and impaired pulmonary function and return to full-time employment were compared. In the multiple non-flail rib fracture group, fracture healing, visual analog scale (VAS) pain score, inpatient length of stay, atelectatic, pulmonary complications, and normal activity-returning time were compared. Patients in the flail chest operative fixation group had significantly shorter ICU stay, decreased ventilator requirements, fewer tracheostomies, less thoracic deformity and impaired pulmonary function, and more returned to full-time employment. Patients in the multiple non-flail rib fracture operative fixation had shorter hospital stay, less pain, earlier return to normal activity, more fracture healing, less atelectasis, and fewer pulmonary infections. This study demonstrates the potential benefits of surgical stabilization of flail chest and multiple non-flail rib fractures with plate fixation. When compared with conventional conservative management, operatively managed patients demonstrated improved clinical outcomes.

  19. A combined experimental and numerical approach for the control and monitoring of the SPES target during operation at high temperature

    NASA Astrophysics Data System (ADS)

    Ballan, Michele; Manzolaro, Mattia; Meneghetti, Giovanni; Andrighetto, Alberto; Monetti, Alberto; Bisoffi, Giovanni; Prete, Gianfranco

    2016-06-01

    The SPES project at INFN-LNL aims at the production of neutron-rich Radioactive Ion Beams (RIBs) using the ISOL (Isotope Separation On Line) technique. A 40 MeV 200 μA proton beam will directly impinge a uranium carbide target, generating approximately 1013 fissions per second. The target system is installed under vacuum inside a water-cooled chamber, and have to maintain high working temperatures, close to 2000 °C. During operation the proton beam provides the heating power required to keep the target at the desired temperature level. As a consequence, its characteristics have to be strictly controlled in order to avoid undesired overheating. According to the original design of the control system, the proton beam can be suddenly interrupted in case of out of range vacuum or cooling water flow levels. With the aim to improve the reliability of the control system a set of temperature sensors has been installed close to the target. Their types and installation positions were defined taking into consideration the detailed information coming from a dedicated thermal-electric model that allowed to investigate the most critical and inaccessible target hot-spots. This work is focused on the definition and experimental validation of the aforementioned numerical model. Its results were used to appropriately install two type C thermocouples, a PT100 thermo-resistance and a residual primary beam current detector. In addition the numerical model will be used for the definition of appropriate thresholds for each installed temperature sensor, since it allows to define a relationship between the locally measured values with the overall calculated temperature field. In case of over temperatures the monitoring system will send warning signals or in case interrupt the proton beam.

  20. Evaluation of Rib Fractures on a Single-in-plane Image Reformation of the Rib Cage in CT Examinations.

    PubMed

    Dankerl, Peter; Seuss, Hannes; Ellmann, Stephan; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2017-02-01

    This study aimed to evaluate the diagnostic performance of using a reformatted single-in-plane image reformation of the rib cage for the detection of rib fractures in computed tomography (CT) examinations, employing different levels of radiological experience. We retrospectively evaluated 10 consecutive patients with and 10 patients without rib fractures, whose CT scans were reformatted to a single-in-plane image reformation of the rib cage. Eight readers (two radiologists, two residents in radiology, and four interns) independently evaluated the images for the presence of rib fractures using a reformatted single-in-plane image and a multi-planar image reformation. The time limit was 30 seconds for each read. A consensus of two radiologist readings was considered as the reference standard. Diagnostic performance (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) was assessed and evaluated per rib and per location (anterior, lateral, posterior). To determine the time limit, we prospectively analyzed the average time it took radiologists to assess the rib cage, in a bone window setting, in 50 routine CT examinations. McNemar test was used to compare the diagnostic performances. Single image reformation was successful in all 20 patients. The sensitivity, specificity, PPV, and NPV for the detection of rib fractures using the conventional multi-planar read were 77.5%, 99.2%, 89.9%, and 98.0% for radiologists; 46.3%, 99.7%, 92.5%, and 95.3% for residents; and 29.4%, 99.4%, 82.5%, and 93.9% for interns, respectively. Sensitivity, PPV, and NPV increased across all three groups of experience, using the reformatted single-in-plane image of the rib cage (radiologists: 85.0%, 98.6%, and 98.7%; residents: 80.0%, 92.8%, and 98.2%; interns: 66.9%, 89.9%, and 97.1%), whereas specificity did not change significantly (99.9%, 99.4%, and 99.3%). The diagnostic performance of the interns and residents was significantly better when evaluating the single-in-plane image reformations (P < .01). The diagnostic performance of the radiologists was better when evaluating the single-in-plane image reformations; however, there was no significant difference (statistical power: 0.32). The diagnostic performance for the detection of rib fractures, using CT images that have been reformatted to a single-in-plane image, improves for readers from different educational levels when the evaluation time is restricted to 30 seconds or less. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Physics Goals for the Planned Next Linear Collider Engineering Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raubenheimer, Tor O

    2001-10-02

    The Next Linear Collider (NLC) Collaboration is planning to construct an Engineering Test Facility (ETF) at Fermilab. As presently envisioned, the ETF would comprise a fundamental unit of the NLC main linac to include X-band klystrons and modulators, a delay-line power-distribution system (DLDS), and NLC accelerating structures that serve as loads. The principal purpose of the ETF is to validate stable operation of the power-distribution system, first without beam, then with a beam having the NLC pulse structure. This paper concerns the possibility of configuring and using the ETF to accelerate beam with an NLC pulse structure, as well asmore » of doing experiments to measure beam-induced wakefields in the rf structures and their influence back on the beam.« less

  2. Physics goals for the planned next linear collider engineering test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Courtlandt L Bohn et al.

    2001-06-26

    The Next Linear Collider (NLC) Collaboration is planning to construct an Engineering Test Facility (ETF) at Fermilab. As presently envisioned, the ETF would comprise a fundamental unit of the NLC main linac to include X-band klystrons and modulators, a delay-line power-distribution system (DLDS), and NLC accelerating structures that serve as loads. The principal purpose of the ETF is to validate stable operation of the power-distribution system, first without beam, then with a beam having the NLC pulse structure. This paper concerns the possibility of configuring and using the ETF to accelerate beam with an NLC pulse structure, as well asmore » of doing experiments to measure beam-induced wakefields in the rf structures and their influence back on the beam.« less

  3. Physics goals for the planned next linear collider engineering test facility.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bohn, C.; Michelotti, L.; Ostiguy, J.-F.

    2001-07-17

    The Next Linear Collider (NLC) Collaboration is planning to construct an Engineering Test Facility (ETF) at Fermilab. As presently envisioned, the ETF would comprise a fundamental unit of the NLC main linac to include X-band klystrons and modulators, a delay-line power-distribution system (DLDS), and NLC accelerating structures that serve as loads. The principal purpose of the ETF is to validate stable operation of the power-distribution system, first without beam, then with a beam having the NLC pulse structure. This paper concerns the possibility of configuring and using the ETF to accelerate beam with an NLC pulse structure, as well asmore » of doing experiments to measure beam-induced wakefields in the rf structures and their influence back on the beam.« less

  4. The Scientific program with RIBRAS (Radioactive Ion Beams in Brasil)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lichtenthaeler, R.; Lepine-Szily, A.; Guimaraes, V.

    The Radioactive Ion Beams Facility (RIBRAS) is in operation since 2004 at the Pelletron Accelerator Laboratory of the University of Sao Paulo and consists of two superconducting solenoids capable of producing low energy secondary beams of light exotic nuclei. Measurements of the elastic scattering, breakup and transfer reactions with radioactive projectiles such as {sup 6}He,{sup 8}Li,{sup 7}Be on several targets have been performed. A review of the research program carried on along the last four years using the RIBRAS facility is presented.

  5. Study of breakup and transfer of weakly bound nucleus 6Li to explore the low energy reaction dynamics

    NASA Astrophysics Data System (ADS)

    Zhang, G. L.; Zhang, G. X.; Hu, S. P.; Zhang, H. Q.; Gomes, P. R. S.; Lubian, J.; Guo, C. L.; Wu, X. G.; Yang, J. C.; Zheng, Y.; Li, C. B.; He, C. Y.; Zhong, J.; Li, G. S.; Yao, Y. J.; Guo, M. F.; Sun, H. B.; Valiente-Dobòn, J. J.; Goasduff, A.; Siciliano, M.; Galtarosa, F.; Francesco, R.; Testov, D.; Mengoni, D.; Bazzacco, D.; John, P. R.; Qu, W. W.; Wang, F.; Zheng, L.; Yu, L.; Chen, Q. M.; Luo, P. W.; Li, H. W.; Wu, Y. H.; Zhou, W. K.; Zhu, B. J.; Li, E. T.; Hao, X.

    2017-11-01

    Investigation of the breakup and transfer effect of weakly bound nuclei on the fusion process has been an interesting research topic in the past several years. However, owing to the low intensities of the presently available radioactive ion beam (RIB), it is difficult to clearly explore the reaction mechanisms of nuclear systems with unstable nuclei. In comparison with RIB, the beam intensities of stable weakly bound nuclei such as 6,7Li and 9Be, which have significant breakup probability, are orders of magnitude higher. Precise fusion measurements have already been performed with those stable weakly bound nuclei, and the effect of breakup of those nuclei on the fusion process has been extensively studied. Those nuclei indicated large production cross sections for particles other than the α + x breakup. The particles are originated from non-capture breakup (NCBU), incomplete fusion (ICF) and transfer processes. However, the conclusion of reaction dynamics was not clear and has the contradiction. In our previous experiments we have performed 6Li+96Zr and 154Sm at HI-13 Tandem accelerator of China Institute of Atomic Energy (CIAE) by using HPGe array. It is shown that there is a small complete fusion (CF) suppression on medium-mass target nucleus 96Zr different from about 35% suppression on heavier target nucleus 154Sm at near-barrier energies. It seems that the CF suppression factor depends on the charge of target nuclei. We also observed one neutron transfer process. However, the experimental data are scarce for medium-mass target nuclei. In order to have a proper understanding of the influence of breakup and transfer of weakly bound projectiles on the fusion process, we performed the 6Li+89Y experiment with incident energies of 22 MeV and 34 MeV on Galileo array in cooperation with Si-ball EUCLIDES at Legnaro National Laboratory (LNL) in Italy. Using particle-particle and particle-γ coincidences, the different reaction mechanisms can be clearly explored.

  6. Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography.

    PubMed

    Razavi, Touraj; Palmer, Richard M; Davies, Jonathan; Wilson, Ron; Palmer, Paul J

    2010-07-01

    To assess the accuracy of measuring the cortical bone thickness adjacent to dental implants using two cone beam computed tomography (CBCT) systems. Ten 4 x 11 mm Astra Tech implants were placed at varying distances from the cortical bone in two prepared bovine ribs. Both ribs were scanned in a reproducible position using two different CBCT scanners. Ten examiners each carried out four measurements on all 10 implants using the two CBCT systems: vertical distance between the top of the implant and the alveolar crest (IT-AC), and thickness of the cortical bone from the outer surface of the implant threads at 3, 6 and 9 mm from the top of the implant. Ground sections were prepared and bone thickness was measured using a light microscope and a graticule to give a gold standard (GS) measurement. The examiner's measurements were significantly different between CBCT systems for the vertical and thickness dimensions (P<0.001) while measuring the cortical bone thickness between 0.3 and 3.7 mm. Within that range, i-CAT NG measurements were consistently underestimated in comparison with the GS. Accuitomo 3D60 FPD measurements closely approximated the GS, except when cortical bone thickness was <0.8 mm. The mean percentage errors from the GS at 3, 6 and 9 mm measurement levels were 68%, 28% and 18%, respectively, for i-CAT NG and 23%, 5% and 6%, respectively, for Accuitomo 3D60 FPD. Within the limitations of this study, it was concluded that i-CAT NG (voxel size 0.3) may not produce sufficient resolution of the thin cortical bone adjacent to dental implants and, therefore, the measurements may not be accurate; whereas, Accuitomo 3D60 FPD (voxel size 0.125) may produce better resolution and more accurate measurement of the thin bone.

  7. 20 CFR 225.22 - Employee RIB PIA used in survivor annuities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... This PIA is computed in accordance with section 215 of the Social Security Act using the deceased... RETIREMENT ACT PRIMARY INSURANCE AMOUNT DETERMINATIONS PIA's Used in Computing Survivor Annuities and the... Employee Retirement Insurance Benefit PIA (Employee RIB PIA) is used to compute the employee RIB amount...

  8. FUEL ELEMENT SUPPORT

    DOEpatents

    Wyman, W.L.

    1961-06-27

    The described cylindrical fuel element has longitudinally spaced sets of short longitudinal ribs circumferentially spaced from one another. The ribs support the fuel element in a coolant tube so that there is an annular space for coolant flow between the fuel element and the interior of the coolant tube. If the fuel element grows as a result of reactor operation, the circumferential distribution of the ribs maintains the uniformity of the annular space between the coolant tube and the fuel element, and the collapsibility of the ribs prevents the fuel element from becoming jammed in the coolant tube.

  9. Analysis and test of a 16-foot radial rib reflector developmental model

    NASA Technical Reports Server (NTRS)

    Birchenough, Shawn A.

    1989-01-01

    Analytical and experimental modal tests were performed to determine the vibrational characteristics of a 16-foot diameter radial rib reflector model. Single rib analyses and experimental tests provided preliminary information relating to the reflector. A finite element model predicted mode shapes and frequencies of the reflector. The analyses correlated well with the experimental tests, verifying the modeling method used. The results indicate that five related, characteristic mode shapes form a group. The frequencies of the modes are determined by the relative phase of the radial ribs.

  10. Thoracic Outlet Syndrome in a Volleyball Player Due to Nonunion of the First Rib Fracture.

    PubMed

    Puttmann, Kathleen T; Satiani, Bhagwan; Vaccaro, Patrick

    2016-11-01

    Fracture of the first rib with ensuing callus formation is a rare cause of thoracic outlet syndrome. We report a case of a 17-year-old female volleyball player who presented with months of chronic arm pain. Radiographic imaging demonstrated nonunion fracture of the first rib. Physical therapy had been unsuccessful in relieving the pain, and surgical management was performed with resection of the first rib through a transaxillary approach with complete resolution of symptoms. Inflammation surrounding such fractures may destroy tissue planes, making dissection more technically difficult.

  11. SU8 inverted-rib waveguide Bragg grating filter.

    PubMed

    Huang, Cheng-Sheng; Wang, Wei-Chih

    2013-08-01

    A polymeric SU8 inverted-rib waveguide Bragg grating filter fabricated using reactive ion etching (RIE) and solvent assisted microcontact molding (SAMIM) is presented. SAMIM is one kind of soft lithography. The technique is unique in that a composite hard-polydimethysiloxane/polydimethysiloxane stamp is used to transfer the grating pattern onto an inverted SU8 rib waveguide system. The composite grating stamp can be used repeatedly several times without degradation. Using this stamp and inverter-rib waveguide structure, the Bragg grating filter fabrication can be significantly simplified. The experiment result shows an attenuation dip in the transmission spectra, with a value of -7 dBm at 1550 nm for a grating with a period of 0.492 μm on an inverted-rib waveguide with 6.6 μm width and 4 μm height.

  12. Comprehensive approach to the management of the patient with multiple rib fractures: a review and introduction of a bundled rib fracture management protocol.

    PubMed

    Witt, Cordelie E; Bulger, Eileen M

    2017-01-01

    Rib fractures are common among patients sustaining blunt trauma, and are markers of severe bodily and solid organ injury. They are associated with high morbidity and mortality, including multiple pulmonary complications, and can lead to chronic pain and disability. Clinical and radiographic scoring systems have been developed at several institutions to predict risk of complications. Clinical strategies to reduce morbidity have been studied, including multimodal pain management, catheter-based analgesia, pulmonary hygiene, and operative stabilization. In this article, we review risk factors for morbidity and complications, intervention strategies, and discuss experience with bundled clinical pathways for rib fractures. In addition, we introduce the multidisciplinary rib fracture management protocol used at our level I trauma center.

  13. Assessment and management of rib fracture pain in geriatric population: an ode to old age.

    PubMed

    Wardhan, Richa

    2013-10-01

    Pain management for traumatic rib fractures has been described in literature, but there is paucity of data when it comes to acute pain management in the elderly, let alone pain resulting from traumatic rib fractures. This article focuses on challenges of assessment of pain in elderly patients and the various options available for pain management including utilization of nerve blocks. Nerve blocks are instrumental in treating rib fracture pain along with utilization of opioids and nonopioids thus formulating a multimodal approach to pain management. The goal is to devise a proper pain management regimen for geriatric patients with rib fractures to decrease the morbidity and mortality associated with it. Developing institutional protocols is one step forward towards quality care for such patients.

  14. The respective effect of under-rib convection and pressure drop of flow fields on the performance of PEM fuel cells

    PubMed Central

    Wang, Chao; Zhang, Qinglei; Shen, Shuiyun; Yan, Xiaohui; Zhu, Fengjuan; Cheng, Xiaojing; Zhang, Junliang

    2017-01-01

    The flow field configuration plays an important role on the performance of proton exchange membrane fuel cells (PEMFCs). For instance, channel/rib width and total channel cross-sectional area determine the under-rib convection and pressure drop respectively, both of which directly influence the water removal, in turn affecting the oxygen supply and cathodic oxygen reduction reaction. In this study, effects of under-rib convection and pressure drop on cell performance are investigated experimentally and numerically by adjusting the channel/rib width and channel cross-sectional area of flow fields. The results show that the performance differences with various flow field configurations mainly derive from the oxygen transport resistance which is determined by the water accumulation degree, and the cell performance would benefit from the narrower channels and smaller cross sections. It reveals that at low current densities when water starts to accumulate in GDL at under-rib regions, the under-rib convection plays a more important role in water removal than pressure drop does; in contrast, at high current densities when water starts to accumulate in channels, the pressure drop dominates the water removal to facilitate the oxygen transport to the catalyst layer. PMID:28251983

  15. Rib Diced Cartilage-Fascia Grafting in Dorsal Nasal Reconstruction: A Randomized Clinical Trial of Wrapping With Rectus Muscle Fascia vs Deep Temporal Fascia.

    PubMed

    As'adi, Kamran; Salehi, Seyed Hamid; Shoar, Saeed

    2014-08-01

    Rib cartilage is an abundant source for cartilage grafts when significant dorsal nasal augmentation or structural support is indicated. Diced cartilage wrapped in fascia was developed to counteract warping, visibility, and displacement of rib cartilage as a dorsal solid graft. The technique for wrapping diced cartilage has evolved during the past several years. The authors compared 2 distinct fascial sleeves for wrapping rib diced cartilage in the treatment of patients who required major dorsal nasal augmentation. Thirty-six patients who planned to undergo major dorsal nasal reconstruction with diced costal rib cartilage were assigned randomly to 1 of 2 groups: the intervention group, which received grafts wrapped with rectus muscle fascia from the rib cartilage harvesting site, or the control group, which received deep temporal fascia harvested separately. Outcomes were compared between the groups. Patients in the intervention group had significantly shorter operating times, significantly higher average satisfaction scores, and significantly shorter postoperative hospital stays than did patients in the control group. Harvesting rectus muscle fascia for wrapping diced rib cartilage is a feasible and reliable technique in dorsal nasal reconstruction surgery. It is associated with favorable outcomes and a high level of patient satisfaction. 4. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  16. Design and testing of integrated Bragg grating sensor systems for advanced grid structure

    NASA Astrophysics Data System (ADS)

    Amano, Masataro; Mizutani, Tadahito; Okabe, Yoji; Takeda, Nobuo; Ozaki, Tsuyoshi

    2006-03-01

    In this research, the authors target on the construction of structural health monitoring system of Advanced Grid Structure (AGS) made of Carbon fiber reinforced plastic (CFRP). AGS has often been applied to aerospace structures because of the following advantages: (1) Since ribs carry only axial forces, the weakness in the transverse direction of the CFRP unidirectional laminates is negligible. (2) AGS has damage tolerance because the fracture of a rib hardly affects other ribs, namely AGS is a fail-safe structure. In this research, in order to detect existence and regions of rib fractures in AGS, we embedded multiplexed fiber Bragg grating (FBG) sensors into AGS in rib longitudinal directions for measurement of strains. Monitoring of the change in rib longitudinal strains is the most effective SHM system for AGS. In order to confirm our proposal, we carried out following discussions. First, we analytically revealed that the change in rib longitudinal strains was the most sensitive signal for damage detection because of AGS's structural redundancy. Then, we introduced a statistical outlier analysis technique into the SHM system for damage recognition. Finally, we established AGS with the SHM system and verified experimentally. The result of the test showed that damage existence and regions in AGS could be detected with the proposed SHM system.

  17. Spontaneous rib fractures.

    PubMed

    Katrancioglu, Ozgur; Akkas, Yucel; Arslan, Sulhattin; Sahin, Ekber

    2015-07-01

    Other than trauma, rib fracture can occur spontaneously due to a severe cough or sneeze. In this study, patients with spontaneous rib fractures were analyzed according to age, sex, underlying pathology, treatment, and complications. Twelve patients who presented between February 2009 and February 2011 with spontaneous rib fracture were reviewed retrospectively. The patients' data were evaluated according to anamnesis, physical examination, and chest radiographs. The ages of the patients ranged from 34 to 77 years (mean 55.91 ± 12.20 years), and 7 (58.4%) were male. All patients had severe cough and chest pain. The fractures were most frequently between 4th and 9th ribs; multiple rib fractures were detected in 5 (41.7%) patients. Eight (66.7%) patients had chronic obstructive pulmonary disease, 2 (16.7%) had bronchial asthma, and 2 (16.7%) had osteoporosis. Bone densitometry revealed a high risk of bone fracture in all patients. Patients with chronic obstructive pulmonary disease or bronchial asthma had been treated with high-dose steroids for over a year. Spontaneous rib fracture due to severe cough may occur in patients with osteoporosis, chronic obstructive pulmonary disease, or bronchial asthma, receiving long-term steroid therapy. If these patients have severe chest pain, chest radiography should be performed to check for bone lesions. © The Author(s) 2015.

  18. Enhanced heat transfer with full circumferential ribs in helical pipe

    NASA Astrophysics Data System (ADS)

    Chang, S. W.; Su, L. M.; Yang, T. L.

    2002-08-01

    This paper describes an experimental study of heat transfers in the smooth-walled and rib-roughened helical pipes with reference to the design of enhanced cooling passages in the cylinder head and liner of a marine propulsive diesel engine. The manner in which the repeated ribs modify the forced heat convection in the helical pipe is considered for the case where the flow is turbulent upon entering the coil but laminar in further downstream. A selection of experimental results illustrates the individual and interactive effects of Dean vortices and rib-flows on heat transfer along the inner and outer helixes of coils. The experimental-based observations reveal that the centrifugal force modifies the heat transfer in a manner to generate circumferential heat transfer variation with better cooling performance on the outer edge relative to its inner counterpart even with the agitated flow field caused by the repeated ribs. Heat transfer augmentation factor in the range of 1.3 - 3 times of the smooth-walled level is achieved using the present ribbing geometry. A set of empirical correlations based on the experimental data has been developed to permit the evaluation of heat transfers along the inner and outer helixes of the smooth-walled and rib-roughened helical pipes.

  19. A Study on the Performance of the Split Reaction Water Turbine with Guide Ribs

    NASA Astrophysics Data System (ADS)

    Allen, Deuel H.; Villanueva, Eliseo P.

    2015-09-01

    The development of technologies that make use of renewable energy is of great significance presently. A new kind of turbine called Split Reaction Water Turbine (SRWT) using PVC pipes as material is a major contribution towards harnessing the energy potentials of small stream low head water resources. SRWTs of diameter to height ratio (D/H = 110 cm/160 cm) were tested at the MSU-IIT College of Engineering Fluid Engineering Laboratory. Data on volumetric flow and pressure head at the turbine inlet of the SRWT were recorded using National Instrument Data Processing System using LabView software. In later experiments, guide ribs were installed at the vane of the exit nozzles in order to determine the difference in the performance of the ribbed and the non-ribbed SRWT. Simulations of the running SRWT were conducted using SOLIDWORKS software. Results of the simulations aided in the thorough analyses of the data from the experimental runs. A comparison of data from the ribbed and non-ribbed SRWT shows that guide ribs were effective in directing the momentum of the exiting water to improve the speed of rotation. In this study, the increase in the speed of the Split Reaction Water Turbine was as much as 46%.

  20. Rib fractures predict incident limb fractures: results from the European prospective osteoporosis study.

    PubMed

    Ismail, A A; Silman, A J; Reeve, J; Kaptoge, S; O'Neill, T W

    2006-01-01

    Population studies suggest that rib fractures are associated with a reduction in bone mass. While much is known about the predictive risk of hip, spine and distal forearm fracture on the risk of future fracture, little is known about the impact of rib fracture. The aim of this study was to determine whether a recalled history of rib fracture was associated with an increased risk of future limb fracture. Men and women aged 50 years and over were recruited from population registers in 31 European centres for participation in a screening survey of osteoporosis (European Prospective Osteoporosis Study). Subjects were invited to complete an interviewer-administered questionnaire that included questions about previous fractures including rib fracture, the age of their first fracture and also the level of trauma. Lateral spine radiographs were performed and the presence of vertebral deformity was determined morphometrically. Following the baseline survey, subjects were followed prospectively by annual postal questionnaire to determine the occurrence of clinical fractures. The subjects included 6,344 men, with a mean age of 64.2 years, and 6,788 women, with a mean age of 63.6 years, who were followed for a median of 3 years (range 0.4-5.9 years), of whom 135 men (2.3%) and 101 women (1.6%) reported a previous low trauma rib fracture. In total, 138 men and 391 women sustained a limb fracture during follow-up. In women, after age adjustment, those with a recalled history of low trauma rib fracture had an increased risk of sustaining 'any' limb fracture [relative hazard (RH)=2.3; 95% CI 1.3, 4.0]. When stratified by fracture type the predictive risk was more marked for hip (RH=7.7; 95% CI 2.3, 25.9) and humerus fracture (RH=4.5; 95% CI 1.4, 14.6) than other sites (RH=1.6; 95% CI 0.6, 4.3). Additional adjustment for prevalent vertebral deformity and previous (non-rib) low trauma fractures at other sites slightly reduced the strength of the association between rib fracture and subsequent limb fracture. In men, after age adjustment, there was a small though non-significant association between recalled history of rib fracture and future limb fracture. Our data highlight the importance of rib fracture as a marker of bone fragility in women.

  1. Experimental investigation of heat transfer and flow using V and broken V ribs within gas turbine blade cooling passage

    NASA Astrophysics Data System (ADS)

    Kumar, Sourabh; Amano, R. S.

    2015-05-01

    Gas turbines are extensively used for aircraft propulsion, land-based power generation, and various industrial applications. With an increase in turbine rotor inlet temperatures, developments in innovative gas turbine cooling technology enhance the efficiency and power output; these advancements of turbine cooling have allowed engine designs to exceed normal material temperature limits. For internal cooling design, techniques for heat extraction from the surfaces exposed to hot stream of gas are based on an increase in the heat transfer areas and on the promotion of turbulence of the cooling flow. In this study, an improvement in performance is obtained by casting repeated continuous V- and broken V-shaped ribs on one side of the two pass square channels into the core of the blade. A detailed experimental investigation is done for two pass square channels with a 180° turn. Detailed heat transfer distribution occurring in the ribbed passage is reported for a steady state experiment. Four different combinations of 60° V- and broken 60° V-ribs in a channel are considered. A series of thermocouples are used to obtain the temperature on the channel surface and local heat transfer coefficients are obtained for Reynolds numbers 16,000, 56,000 and 85,000 within the turbulent flow regime. Area averaged data are calculated in order to compare the overall performance of the tested ribbed surface and to evaluate the degree of heat transfer enhancement induced by the rib. Flow within the channels is characterized by heat transfer enhancing ribs, bends, rotation and buoyancy effects. A series of experimental measurements is performed to predict the overall performance of the channel. This paper presents an attempt to collect information about the Nusselt number, the pressure drop and the overall performance of the eight different ribbed ducts at the specified Reynolds number. The main contribution of this study is to evaluate the best combination of rib arrangements throughout the two pass cooling channels. After a series of experiments, it can be concluded that the distribution of peaks in heat transfer in the case of inlet V and outlet inverted V is high. The overall performances for broken ribs are higher compared with the continuous ribs in two-pass cooling channels.

  2. A Dual-Beam Irradiation Facility for a Novel Hybrid Cancer Therapy

    NASA Astrophysics Data System (ADS)

    Sabchevski, Svilen Petrov; Idehara, Toshitaka; Ishiyama, Shintaro; Miyoshi, Norio; Tatsukawa, Toshiaki

    2013-01-01

    In this paper we present the main ideas and discuss both the feasibility and the conceptual design of a novel hybrid technique and equipment for an experimental cancer therapy based on the simultaneous and/or sequential application of two beams, namely a beam of neutrons and a CW (continuous wave) or intermittent sub-terahertz wave beam produced by a gyrotron for treatment of cancerous tumors. The main simulation tools for the development of the computer aided design (CAD) of the prospective experimental facility for clinical trials and study of such new medical technology are briefly reviewed. Some tasks for a further continuation of this feasibility analysis are formulated as well.

  3. Cavity beam position monitor system for the Accelerator Test Facility 2

    NASA Astrophysics Data System (ADS)

    Kim, Y. I.; Ainsworth, R.; Aryshev, A.; Boogert, S. T.; Boorman, G.; Frisch, J.; Heo, A.; Honda, Y.; Hwang, W. H.; Huang, J. Y.; Kim, E.-S.; Kim, S. H.; Lyapin, A.; Naito, T.; May, J.; McCormick, D.; Mellor, R. E.; Molloy, S.; Nelson, J.; Park, S. J.; Park, Y. J.; Ross, M.; Shin, S.; Swinson, C.; Smith, T.; Terunuma, N.; Tauchi, T.; Urakawa, J.; White, G. R.

    2012-04-01

    The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1μm for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.

  4. Measurements and FLUKA simulations of bismuth and aluminium activation at the CERN Shielding Benchmark Facility (CSBF)

    NASA Astrophysics Data System (ADS)

    Iliopoulou, E.; Bamidis, P.; Brugger, M.; Froeschl, R.; Infantino, A.; Kajimoto, T.; Nakao, N.; Roesler, S.; Sanami, T.; Siountas, A.

    2018-03-01

    The CERN High Energy AcceleRator Mixed field facility (CHARM) is located in the CERN Proton Synchrotron (PS) East Experimental Area. The facility receives a pulsed proton beam from the CERN PS with a beam momentum of 24 GeV/c with 5 ṡ1011 protons per pulse with a pulse length of 350 ms and with a maximum average beam intensity of 6.7 ṡ1010 p/s that then impacts on the CHARM target. The shielding of the CHARM facility also includes the CERN Shielding Benchmark Facility (CSBF) situated laterally above the target. This facility consists of 80 cm of cast iron and 360 cm of concrete with barite concrete in some places. Activation samples of bismuth and aluminium were placed in the CSBF and in the CHARM access corridor in July 2015. Monte Carlo simulations with the FLUKA code have been performed to estimate the specific production yields for these samples. The results estimated by FLUKA Monte Carlo simulations are compared to activation measurements of these samples. The comparison between FLUKA simulations and the measured values from γ-spectrometry gives an agreement better than a factor of 2.

  5. NRL Review, 2002

    DTIC Science & Technology

    2002-05-01

    technology for polarization-maintaining fiber amplification and an ultrashort pulsed fiber laser to Calmar Optcom. Calmar Optcom will be manufacturing...June 1995. This facility is made up of 56 laser beams and is single pulsed (4 nanosecond pulse ). This facil- ity provides intense radiation for studying...plasma interactions, in- tense laser -electron beam interactions, and intense laser -matter interactions. The division is building a repetitively pulsed (5

  6. A facility to produce an energetic, ground state atomic oxygen beam for the simulation of the Low-Earth Orbit environment

    NASA Technical Reports Server (NTRS)

    Ketsdever, Andrew D.; Weaver, David P.; Muntz, E. P.

    1994-01-01

    Because of the continuing commitment to activity in low-Earth orbit (LEO), a facility is under development to produce energetic atmospheric species, particularly atomic oxygen, with energies ranging from 5 to 80 eV. This relatively high flux facility incorporates an ion engine to produce the corresponding specie ion which is charge exchanged to produce a neutral atomic beam. Ion fluxes of around 10(exp 15) sec(exp -1) with energies of 20-70 eV have been achieved. A geometrically augmented inertially tethered charge exchanger (GAITCE) was designed to provide a large column depth of charge exchange gas while reducing the gas load to the low pressure portion of the atomic beam facility. This is accomplished using opposed containment jets which act as collisional barriers to the escape of the dense gas region formed between the jets. Leak rate gains to the pumping system on the order of 10 were achieved for moderate jet mass flows. This system provides an attractive means for the charge exchange of atomic ions with a variety of gases to produce energetic atomic beams.

  7. The clinical implications of severe low rib fracture in the management of diaphragm injury: A Case Control Study.

    PubMed

    Kim, Seongyup; Choi, Woo Jin; Lee, Kawng Ho; Byun, Chun Sung; Bae, Keum Seok; Park, Il Hwan

    2017-06-01

    The objective of this study was to analyze the differences in clinical presentation and characteristics with regard to diaphragmatic injury between blunt trauma patients with severe low rib fractures and those without severe low rib fractures. The medical records of all patients with diaphragmatic injuries who were surgically treated at this level I trauma center, between January 2004 and December 2016 were reviewed. Patient notes, radiologic findings, and operative reports were evaluated. All of the diaphragmatic injuries were confirmed based on the operative findings. Rib fracture with displacement between the ends of the fracture of more than half the width of the fractured rib on computed tomography was classified as 'severe rib fracture'. Patients were categorized into 2 groups and analyzed: those who had more than one severe rib fracture in low ribs on the ipsilateral side of the diaphragm injury (Severe group), and those with no severe rib fracture (Non-severe group). Delayed diagnosis of diaphragmatic injury was more frequent in the Severe group than in the Non-severe group (81.8% vs 36.8%, p-value = 0.026). With regard to initial indications for operation, intrathoracic visceral herniation was more frequent in the Non-severe group (78.9% vs 18.2%, p-value = 0.002), while hemothorax was more frequent in the Severe group (63.6% vs 5.3%, p-value = 0.001). Central type diaphragmatic laceration was more frequent in the Non-severe group than in the Severe group (78.9% vs 18.2%, p-value = 0.002). The diameter of diaphragmatic injury was larger in the Non-severe group than in the Severe group (9.70 ± 4.10 cm vs 4.80 ± 3.60 cm, p-value = 0.004). The results of this study imply that a low threshold for thoracotomy or laparotomy should be considered in blunt trauma patients with severe low rib fractures for the purpose of hidden diaphragmatic injury detection and management. Copyright © 2017. Published by Elsevier Ltd.

  8. Optimal Central Obesity Measurement Site for Assessing Cardiometabolic and Type 2 Diabetes Risk in Middle-Aged Adults

    PubMed Central

    Millar, Seán R.; Perry, Ivan J.; Phillips, Catherine M.

    2015-01-01

    Objectives Despite recommendations that central obesity assessment should be employed as a marker of cardiometabolic health, no consensus exists regarding measurement protocol. This study examined a range of anthropometric variables and their relationships with cardiometabolic features and type 2 diabetes in order to ascertain whether measurement site influences discriminatory accuracy. In particular, we compared waist circumference (WC) measured at two sites: (1) immediately below the lowest rib (WC rib) and (2) between the lowest rib and iliac crest (WC midway), which has been recommended by the World Health Organisation and International Diabetes Federation. Materials and Methods This was a cross-sectional study involving a random sample of 2,002 men and women aged 46-73 years. Metabolic profiles and WC, hip circumference, pelvic width and body mass index (BMI) were determined. Correlation, logistic regression and area under the receiver operating characteristic curve analyses were used to evaluate obesity measurement relationships with metabolic risk phenotypes and type 2 diabetes. Results WC rib measures displayed the strongest associations with non-optimal lipid and lipoprotein levels, high blood pressure, insulin resistance, impaired fasting glucose, a clustering of metabolic risk features and type 2 diabetes, in both genders. Rib-derived indices improved discrimination of type 2 diabetes by 3-7% compared to BMI and 2-6% compared to WC midway (in men) and 5-7% compared to BMI and 4-6% compared to WC midway (in women). A prediction model including BMI and central obesity displayed a significantly higher area under the curve for WC rib (0.78, P=0.003), Rib/height ratio (0.80, P<0.001), Rib/pelvis ratio (0.79, P<0.001), but not for WC midway (0.75, P=0.127), when compared to one with BMI alone (0.74). Conclusions WC rib is easier to assess and our data suggest that it is a better method for determining obesity-related cardiometabolic risk than WC midway. The clinical utility of rib-derived indices, or alternative WC measurements, deserves further investigation. PMID:26042771

  9. An electron beam ion trap and source for re-acceleration of rare-isotope ion beams at TRIUMF

    NASA Astrophysics Data System (ADS)

    Blessenohl, M. A.; Dobrodey, S.; Warnecke, C.; Rosner, M. K.; Graham, L.; Paul, S.; Baumann, T. M.; Hockenbery, Z.; Hubele, R.; Pfeifer, T.; Ames, F.; Dilling, J.; Crespo López-Urrutia, J. R.

    2018-05-01

    Electron beam driven ionization can produce highly charged ions (HCIs) in a few well-defined charge states. Ideal conditions for this are maximally focused electron beams and an extremely clean vacuum environment. A cryogenic electron beam ion trap fulfills these prerequisites and delivers very pure HCI beams. The Canadian rare isotope facility with electron beam ion source-electron beam ion sources developed at the Max-Planck-Institut für Kernphysik (MPIK) reaches already for a 5 keV electron beam and a current of 1 A with a density in excess of 5000 A/cm2 by means of a 6 T axial magnetic field. Within the trap, the beam quickly generates a dense HCI population, tightly confined by a space-charge potential of the order of 1 keV times the ionic charge state. Emitting HCI bunches of ≈107 ions at up to 100 Hz repetition rate, the device will charge-breed rare-isotope beams with the mass-over-charge ratio required for re-acceleration at the Advanced Rare IsotopE Laboratory (ARIEL) facility at TRIUMF. We present here its design and results from commissioning runs at MPIK, including X-ray diagnostics of the electron beam and charge-breeding process, as well as ion injection and HCI-extraction measurements.

  10. [Cohort study on the prevalence and risk factors of late pulmonary complications in adults following a closed minor chest trauma].

    PubMed

    Plourde, Miville; Émond, Marcel; Lavoie, André; Guimont, Chantal; Le Sage, Natalie; Chauny, Jean-Marc; Bergeron, Éric; Vanier, Laurent; Moore, Lynne; Allain-Boulé, Nadine; Fratu, Ramona-Florina; Dufresne, Maryline

    2013-11-01

    The objectives of this study are to determine the prevalence, risk factors, and time to onset of delayed hemothorax and pneumothorax in adults who experienced a minor blunt thoracic trauma. A prospective cohort of 450 consecutive patients was recruited. Eligible patients had to be over 16 years of age, consulted within 72 hours for a trauma, and available for outpatient follow-up at 2, 7, and 14 days posttrauma. The clinical outcome investigated was the presence of delayed pneumothorax or hemothorax on the follow-up chest x-ray. Delayed hemothorax occurred in 11.8% (95% CI 8.8-14.8), and delayed pneumothorax occurred in 0.9% (95% CI 0.2-2.3) of participants. During the 14-day follow-up period, 87.0% of these delayed complications developed in the first week. In the multivariate analysis, the only statistically significant risk factor for delayed complications was the location of fractures on the x-ray of the hemithorax. The adjusted odds ratio was 1.52 (95% CI 0.62-3.73) for the lower ribs (tenth to twelfth rib), 3.11 (95% CI 1.60-6.08) for the midline ribs (sixth to ninth rib), and 5.05 (95% CI 1.80-14.19) for the upper ribs (third to fifth rib) versus patients with no fractures. The presence of at least one rib fracture between the third and ninth rib on the x-ray of the hemithorax is a significant risk factor for delayed hemothorax and pneumothorax.

  11. Characterization of Human Rib Biomechanical Responses due to Three-Point Bending.

    PubMed

    Kalra, Anil; Saif, Tal; Shen, Ming; Jin, Xin; Zhu, Feng; Begeman, Paul; Yang, King H; Millis, Scott

    2015-11-01

    In the elderly population, rib fracture is one of the most common injuries sustained in motor vehicle crashes. The current study was conducted to predict the biomechanical fracture responses of ribs with respect to age, gender, height, weight and percentage of ash content. Three-point bending experiments were conducted on 278 isolated rib samples extracted from 82 cadaver specimens (53 males and 29 females between the ages of 21 and 87 years) for 6th and 7th levels of ribs. Statistical analyses were carried out to identify differences based on age and gender. It was found that, in comparison to males, females had significantly lower values for maximum bending moments, slopes of bending moment-angle curves, and average cortical-bone thickness (p<0.05). Samples of ribs taken from elderly specimens failed at lower values of fracture moments than those from younger specimens, and had lower slopes of bending moment-angle curves, both in males and females (p<0.05). The generalized estimated equations were developed to predict the values of biomechanical response and average cortical thickness based on age, gender, height and weight of individual specimens. Results from the current study illustrate that biomechanical responses and rib cortical thicknesses are functions of age, gender, height and weight. However, the current study is limited to a quasi-static loading scheme, which is different from real crash conditions. Hence, rib-material properties, which are dependent on strain rate, and are needed for wholebody finite element models representing different populations, still require more research.

  12. Number of rib fractures thresholds independently predict worse outcomes in older patients with blunt trauma.

    PubMed

    Shulzhenko, Nikita O; Zens, Tiffany J; Beems, Megan V; Jung, Hee Soo; O'Rourke, Ann P; Liepert, Amy E; Scarborough, John E; Agarwal, Suresh K

    2017-04-01

    There have been conflicting reports regarding whether the number of rib fractures sustained in blunt trauma is associated independently with worse patient outcomes. We sought to investigate this risk-adjusted relationship among the lesser-studied population of older adults. A retrospective review of the National Trauma Data Bank was performed for patients with blunt trauma who were ≥65 years old and had rib fractures between 2009 and 2012 (N = 67,695). Control data were collected for age, sex, injury severity score, injury mechanism, 24 comorbidities, and number of rib fractures. Outcome data included hospital mortality, hospital and intensive care unit durations of stay, duration of mechanical ventilation, and the occurrence of pneumonia. Multiple logistic and linear regression analyses were performed. Sustaining ≥5 rib fractures was associated with increased intensive care unit admission (odds ratio: 1.14, P < .001) and hospital duration of stay (relative duration: 105%, P < .001). Sustaining ≥7 rib fractures was associated with an increased incidence of pneumonia (odds ratio: 1.32, P < .001) and intensive care unit duration of stay (relative duration: 122%, P < .001). Sustaining ≥8 rib fractures was associated with increased mortality (odds ratio: 1.51, P < .001) and duration of mechanical ventilation (relative duration: 117%, P < .001). In older patients with trauma, sustaining at least 5 rib fractures is a significant predictor of worse outcomes independent of patient characteristics, comorbidities, and trauma burden. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    PubMed Central

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  14. A 62-MeV Proton Beam for the Treatment of Ocular Melanoma at Laboratori Nazionali del Sud-INFN

    NASA Astrophysics Data System (ADS)

    Cirrone, G. A. P.; Cuttone, G.; Lojacono, P. A.; Lo Nigro, S.; Mongelli, V.; Patti, I. V.; Privitera, G.; Raffaele, L.; Rifuggiato, D.; Sabini, M. G.; Salamone, V.; Spatola, C.; Valastro, L. M.

    2004-06-01

    At the Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Sud (INFN-LNS) in Catania, Italy, the first Italian protontherapy facility, named Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) has been built in collaboration with the University of Catania. It is based on the use of the 62-MeV proton beam delivered by the K=800 Superconducting Cyclotron installed and working at INFN-LNS since 1995. The facility is mainly devoted to the treatment of ocular diseases like uveal melanoma. A beam treatment line in air has been assembled together with a dedicated positioning patient system. The facility has been in operation since the beginning of 2002 and 66 patients have been successfully treated up to now. The main features of CATANA together with the clinical and dosimetric features will be extensively described; particularly, the proton beam line, that has been entirely built at LNS, with all its elements, the experimental transversal and depth dose distributions of the 62-MeV proton beam obtained for a final collimator of 25-mm diameter and the experimental depth dose distributions of a modulated proton beam obtained for the same final collimator. Finally, the clinical results over 1 yr of treatments, describing the features of the treated diseases will be reported.

  15. High and low energy gamma beam dump designs for the gamma beam delivery system at ELI-NP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yasin, Zafar, E-mail: zafar.yasin@eli-np.ro; Matei, Catalin; Ur, Calin A.

    The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) is under construction in Magurele, Bucharest, Romania. The facility will use two 10 PW lasers and a high intensity, narrow bandwidth gamma beam for stand-alone and combined laser-gamma experiments. The accurate estimation of particle doses and their restriction within the limits for both personel and general public is very important in the design phase of any nuclear facility. In the present work, Monte Carlo simulations are performed using FLUKA and MCNPX to design 19.4 and 4 MeV gamma beam dumps along with shielding of experimental areas. Dose rate contour plots from both FLUKAmore » and MCNPX along with numerical values of doses in experimental area E8 of the facility are performed. The calculated doses are within the permissible limits. Furthermore, a reasonable agreement between both codes enhances our confidence in using one or both of them for future calculations in beam dump designs, radiation shielding, radioactive inventory, and other calculations releated to radiation protection. Residual dose rates and residual activity calculations are also performed for high-energy beam dump and their effect is negligible in comparison to contributions from prompt radiation.« less

  16. Design of an epithermal column for BNCT based on D D fusion neutron facility

    NASA Astrophysics Data System (ADS)

    Durisi, E.; Zanini, A.; Manfredotti, C.; Palamara, F.; Sarotto, M.; Visca, L.; Nastasi, U.

    2007-05-01

    Boron Neutron Capture Therapy (BNCT) is currently performed on patients at nuclear reactors. At the same time the international BNCT community is engaged in the development of alternative facilities for in-hospital treatments. This paper investigates the potential of a novel high-output D-D neutron generator, developed at Lawrence Berkeley National Laboratory (CA, USA), for BNCT. The simulation code MCNP-4C is used to realize an accurate study of the epithermal column in view of the treatment of deep tumours. Different materials and Beam Shaping Assemblies (BSA) are investigated and an optimized configuration is proposed. The neutron beam quality is defined by the standard free beam parameters, calculated averaging over the collimator aperture. The results are discussed and compared with the performances of other facilities.

  17. The first target experiments on the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Landen, O. L.; Glenzer, S. H.; Froula, D. H.; Dewald, E. L.; Suter, L. J.; Schneider, M. B.; Hinkel, D. E.; Fernandez, J. C.; Kline, J. L.; Goldman, S. R.; Braun, D. G.; Celliers, P. M.; Moon, S. J.; Robey, H. S.; Lanier, N. E.; Glendinning, S. G.; Blue, B. E.; Wilde, B. H.; Jones, O. S.; Schein, J.; Divol, L.; Kalantar, D. H.; Campbell, K. M.; Holder, J. P.; McDonald, J. W.; Niemann, C.; MacKinnon, A. J.; Collins, G. W.; Bradley, D. K.; Eggert, J. H.; Hicks, D. G.; Gregori, G.; Kirkwood, R. K.; Young, B. K.; Foster, J. M.; Hansen, J. F.; Perry, T. S.; Munro, D. H.; Baldis, H. A.; Grim, G. P.; Heeter, R. F.; Hegelich, M. B.; Montgomery, D. S.; Rochau, G. A.; Olson, R. E.; Turner, R. E.; Workman, J. B.; Berger, R. L.; Cohen, B. I.; Kruer, W. L.; Langdon, A. B.; Langer, S. H.; Meezan, N. B.; Rose, H. A.; Still, C. H.; Williams, E. A.; Dodd, E. S.; Edwards, M. J.; Monteil, M.-C.; Stevenson, R. M.; Thomas, B. R.; Coker, R. F.; Magelssen, G. R.; Rosen, P. A.; Stry, P. E.; Woods, D.; Weber, S. V.; Young, P. E.; Alvarez, S.; Armstrong, G.; Bahr, R.; Bourgade, J.-L.; Bower, D.; Celeste, J.; Chrisp, M.; Compton, S.; Cox, J.; Constantin, C.; Costa, R.; Duncan, J.; Ellis, A.; Emig, J.; Gautier, C.; Greenwood, A.; Griffith, R.; Holdner, F.; Holtmeier, G.; Hargrove, D.; James, T.; Kamperschroer, J.; Kimbrough, J.; Landon, M.; Lee, F. D.; Malone, R.; May, M.; Montelongo, S.; Moody, J.; Ng, E.; Nikitin, A.; Pellinen, D.; Piston, K.; Poole, M.; Rekow, V.; Rhodes, M.; Shepherd, R.; Shiromizu, S.; Voloshin, D.; Warrick, A.; Watts, P.; Weber, F.; Young, P.; Arnold, P.; Atherton, L.; Bardsley, G.; Bonanno, R.; Borger, T.; Bowers, M.; Bryant, R.; Buckman, S.; Burkhart, S.; Cooper, F.; Dixit, S. N.; Erbert, G.; Eder, D. C.; Ehrlich, R. E.; Felker, B.; Fornes, J.; Frieders, G.; Gardner, S.; Gates, C.; Gonzalez, M.; Grace, S.; Hall, T.; Haynam, C. A.; Heestand, G.; Henesian, M. A.; Hermann, M.; Hermes, G.; Huber, S.; Jancaitis, K.; Johnson, S.; Kauffman, B.; Kelleher, T.; Kohut, T.; Koniges, A. E.; Labiak, T.; Latray, D.; Lee, A.; Lund, D.; Mahavandi, S.; Manes, K. R.; Marshall, C.; McBride, J.; McCarville, T.; McGrew, L.; Menapace, J.; Mertens, E.; Murray, J.; Neumann, J.; Newton, M.; Opsahl, P.; Padilla, E.; Parham, T.; Parrish, G.; Petty, C.; Polk, M.; Powell, C.; Reinbachs, I.; Rinnert, R.; Riordan, B.; Ross, G.; Robert, V.; Tobin, M.; Sailors, S.; Saunders, R.; Schmitt, M.; Shaw, M.; Singh, M.; Spaeth, M.; Stephens, A.; Tietbohl, G.; Tuck, J.; van Wonterghem, B. M.; Vidal, R.; Wegner, P. J.; Whitman, P.; Williams, K.; Winward, K.; Work, K.; Wallace, R.; Nobile, A.; Bono, M.; Day, B.; Elliott, J.; Hatch, D.; Louis, H.; Manzenares, R.; O'Brien, D.; Papin, P.; Pierce, T.; Rivera, G.; Ruppe, J.; Sandoval, D.; Schmidt, D.; Valdez, L.; Zapata, K.; MacGowan, B. J.; Eckart, M. J.; Hsing, W. W.; Springer, P. T.; Hammel, B. A.; Moses, E. I.; Miller, G. H.

    2007-08-01

    A first set of shock timing, laser-plasma interaction, hohlraum energetics and hydrodynamic experiments have been performed using the first 4 beams of the National Ignition Facility (NIF), in support of indirect drive Inertial Confinement Fusion (ICF) and High Energy Density Physics (HEDP). In parallel, a robust set of optical and X-ray spectrometers, interferometer, calorimeters and imagers have been activated. The experiments have been undertaken with laser powers and energies of up to 8 TW and 17 kJ in flattop and shaped 1 9 ns pulses focused with various beam smoothing options. The experiments have demonstrated excellent agreement between measured and predicted laser-target coupling in foils and hohlraums, even when extended to a longer pulse regime unattainable at previous laser facilities, validated the predicted effects of beam smoothing on intense laser beam propagation in long scale-length plasmas and begun to test 3D codes by extending the study of laser driven hydrodynamic jets to 3D geometries.

  18. [Initial experience of proton beam therapy at the new facility of the University of Tsukuba].

    PubMed

    Kagei, Kenji; Tokuuye, Koichi; Sugahara, Shinji; Hata, Masaharu; Igaki, Hiroshi; Hashimoto, Takayuki; Ohara, Kiyoshi; Akine, Yasuyuki

    2004-05-01

    To present the initial experience with proton beam therapy at the new Proton Medical Research Center (PMRC) of the University of Tsukuba. The new facility has a synchrotron with maximum energy of 250MeV and two rotational gantries. We treated 105 patients with 120 lesions with proton beams in the first year, beginning in September 2001. The most common lesion treated was primary liver cancer (40 lesions) followed by lung cancer, head and neck cancers, and prostate cancer. Concurrent X-ray radiotherapy was given for 38 of the 120 lesions. The median follow-up period was 11 months (range, 1-19 months). Of the 105 patients, 97% had Grade 0-2 RTOG/EORTC acute morbidities, while the remaining 3% had Grade 3. Tumor response after irradiation was CR for 35% of the lesions, PR for 25%, SD for 22%, PD for 9%, and not evaluated for 9%. The proton beam therapy conducted at the new facility of the University of Tsukuba was safe and effective.

  19. Performance Characterization of the Production Facility Prototype Helium Flow System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woloshun, Keith Albert; Dale, Gregory E.; Dalmas, Dale Allen

    2015-12-16

    The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was need for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GMmore » 12.4 blower was selected, and is currently being installed at the LANL facility for target and component flow testing. This report describes this blower/motor/pressure vessel package and the status of the facility preparations. Blower performance (mass flow rate as a function of loop pressure drop) was measured at 4 blower speeds. Results are reported below.« less

  20. The biomechanics of human ribs: material and structural properties from dynamic tension and bending tests.

    PubMed

    Kemper, Andrew R; McNally, Craig; Pullins, Clayton A; Freeman, Laura J; Duma, Stefan M; Rouhana, Stephen M

    2007-10-01

    The purpose of this study was to quantify both the tensile material properties and structural response of human ribs in order to determine which variables contribute to regional variation in the strength of human ribs. This was done by performing 94 matched tests on human rib specimens; 46 tension coupon tests, 48 three-point bending tests. Contralateral matched specimens were dissected from anterior and lateral regions of ribs 4 through 7 of six male fresh frozen post mortem human subjects ranging from 42 to 81 years of age. Tension coupons were taken from one side of the thorax, while three-point bending specimens were taken from the opposite side as the tension coupons at corresponding anatomical locations. The results of the tension coupon testing showed that there were no significant differences with respect to region or rib level: ultimate stress (p=0.90; p=0.53), ultimate strain (p=0.49; p=0.86), or modulus (p=0.72; p=0.81). In contrast, lateral three-point bending specimens were found to have a significantly higher peak bending moment (p<0.01), peak strain (p=0.03), modulus (p=0.05), and stiffness (p<0.01) than anterior specimens. The lateral three-point bending specimens also had a significantly larger area moment of inertia (p<0.01), larger distance to the neutral axis (p<0.01), smaller ratio of distance to the neutral axis to area moment of inertia (p<0.01), larger cortical bone area (p<0.01), and larger radius of gyration (p<0.01) than the anterior specimens. In addition, the peak moment (Ant p=0.20; Lat p=0.02), peak strain (Ant p=0.05; Lat p=0.15), and stiffness (Ant p<0.01; Lat p<0.01) were found to vary significantly with respect to rib level. Similar to anatomical region, the changes in the structural response with respect to rib level were also accompanied by significant changes in geometry. For anterior specimens, distance to the neutral axis (p<0.01), ratio of the distance to the neutral axis to area moment of inertia (p=0.02) and radius of gyration (p=0.04) were found to be significantly different with respect to rib level. For lateral specimens, the area moment of inertia (p<0.01), distance to the neutral axis (p<0.01), ratio of the distance to the neutral axis to area moment of inertia (p<0.01), the cortical bone area (p=0.01), and radius of gyration (p=0.03) were found to be significantly different with respect to rib level. These results clearly illustrate that there is variation in the structural response of human ribs with respect to anatomical region and rib level and this variation is due to changes in local geometry of each rib while the material properties remain constant.

  1. Surgical resection of melorheostosis in the ribs.

    PubMed

    Chanda, Binayak; Millner, Russell W J

    2007-04-01

    Melorheostosis is a rare nongenetic developmental anomaly of the cortical bone. We present a 40-year-old woman who was diagnosed with melorheostosis affecting the ribs only. Chronic pain and cosmetic deformity were her presenting symptoms. She underwent posterolateral thoracotomy and excision of the affected ribs, with a satisfactory outcome of this uncommon presentation.

  2. Does Cardiopulmonary Resuscitation Cause Rib Fractures in Children? A Systematic Review

    ERIC Educational Resources Information Center

    Maguire, Sabine; Mann, Mala; John, Nia; Ellaway, Bev; Sibert, Jo R.; Kemp, Alison M.

    2006-01-01

    Background: There is a diagnostic dilemma when a child presents with rib fractures after cardiopulmonary resuscitation (CPR) where child abuse is suspected as the cause of collapse. We have performed a systematic review to establish the evidence base for the following questions: (i) Does cardiopulmonary resuscitation cause rib fractures in…

  3. Strategies to improve electrode positioning and safety in cochlear implants.

    PubMed

    Rebscher, S J; Heilmann, M; Bruszewski, W; Talbot, N H; Snyder, R L; Merzenich, M M

    1999-03-01

    An injection-molded internal supporting rib has been produced to control the flexibility of silicone rubber encapsulated electrodes designed to electrically stimulate the auditory nerve in human subjects with severe to profound hearing loss. The rib molding dies, and molds for silicone rubber encapsulation of the electrode, were designed and machined using AutoCad and MasterCam software packages in a PC environment. After molding, the prototype plastic ribs were iteratively modified based on observations of the performance of the rib/silicone composite insert in a clear plastic model of the human scala tympani cavity. The rib-based electrodes were reliably inserted farther into these models, required less insertion force and were positioned closer to the target auditory neural elements than currently available cochlear implant electrodes. With further design improvements the injection-molded rib may also function to accurately support metal stimulating contacts and wire leads during assembly to significantly increase the manufacturing efficiency of these devices. This method to reliably control the mechanical properties of miniature implantable devices with multiple electrical leads may be valuable in other areas of biomedical device design.

  4. Large Eddy Simulation of Turbulent Flow in a Ribbed Pipe

    NASA Astrophysics Data System (ADS)

    Kang, Changwoo; Yang, Kyung-Soo

    2011-11-01

    Turbulent flow in a pipe with periodically wall-mounted ribs has been investigated by large eddy simulation with a dynamic subgrid-scale model. The value of Re considered is 98,000, based on hydraulic diameter and mean bulk velocity. An immersed boundary method was employed to implement the ribs in the computational domain. The spacing of the ribs is the key parameter to produce the d-type, intermediate and k-type roughness flows. The mean velocity profiles and turbulent intensities obtained from the present LES are in good agreement with the experimental measurements currently available. Turbulence statistics, including budgets of the Reynolds stresses, were computed, and analyzed to elucidate turbulence structures, especially around the ribs. In particular, effects of the ribs are identified by comparing the turbulence structures with those of smooth pipe flow. The present investigation is relevant to the erosion/corrosion that often occurs around a protruding roughness in a pipe system. This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (2010-0008457).

  5. Correction of cleft lip nose deformity with rib cartilage.

    PubMed

    Hafezi, Farhad; Naghibzadeh, Bijan; Ashtiani, Abbas Kazemi; Mousavi, S Jaber; Nouhi, Amir Hossein; Naghibzadeh, Ghazal

    2013-07-01

    Correction of cleft lip nasal deformities (CLND) is often unsatisfactory because of problems resulting from cartilage weakness and strong soft tissue forces. Therefore, strong cartilaginous support, such as rib cartilage, is mandatory. The authors describe placement of rib cartilage grafts to create a more symmetric and aesthetically acceptable repair of CLND with improved nasal air flow. Two groups of patients, including those with unilateral and bilateral CLND, underwent operations with different sources of autologous cartilage. Group 1 received grafts from the septum and ear, whereas group 2 received grafts from the septum and ribs. Results were evaluated by 2 independent physicians who rated improvement between pre- and postoperative photographs. There were significant differences in postoperative improvement between patients who received septal/ear cartilage grafts and those who received septal/rib cartilage grafts in both unilateral and bilateral cases (P = .028 and P = .043, respectively). The authors' results demonstrate that rib cartilage has a positive effect on the aesthetic outcome of CLND operations and provides a strong support structure for correcting this deformity with minimal postoperative complications.

  6. Stress fractures of the ribs in elite competitive rowers: a report of nine cases.

    PubMed

    Dragoni, S; Giombini, A; Di Cesare, A; Ripani, M; Magliani, G

    2007-10-01

    The objective was to report the clinical and imaging patterns of nine cases of stress fractures of the rib diagnosed in Italian Olympic rowers. Nine patients with stress fractures of the rib detected from 103 (8.7%) Italian team rowers competing between May 2000 and May 2006 were identified based on the database of a sports medicine institute. All athletes were male. They were aged between 17 and 31 years (mean: 24.4). Patient weight, fracture location, rowing side and imaging methods employed were noted. The diagnosis was made based on history, clinical examination and Tc-99m MDP bone scintigraphy. Eight of the 9 fractures were located anterolaterally between the fourth and ninth rib. In 1 of the 5 athletes with standard radiographs, a fracture line was visible and in 4 there was callus formation. In 2 athletes sonography was performed, which detected discontinuity of the rib surface and callus formation (1 case each). Stress fractures of the ribs are relatively common in competitive rowers. They are characterized by increasing lateral chest pain and typical scintigraphic, radiographic and sonographic findings.

  7. Characterizing the Performance of the Princeton Advanced Test Stand Ion Source

    NASA Astrophysics Data System (ADS)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I.; Davidson, R. C.

    2012-10-01

    The Princeton Advanced Test Stand (PATS) is a compact experimental facility for studying the physics of intense beam-plasma interactions relevant to the Neutralized Drift Compression Experiment - II (NDCX-II). The PATS facility consists of a multicusp RF ion source mounted on a 2 m-long vacuum chamber with numerous ports for diagnostic access. Ar+ beams are extracted from the source plasma with three-electrode (accel-decel) extraction optics. The RF power and extraction voltage (30 - 100 kV) are pulsed to produce 100 μsec duration beams at 0.5 Hz with excellent shot-to-shot repeatability. Diagnostics include Faraday cups, a double-slit emittance scanner, and scintillator imaging. This work reports measurements of beam parameters for a range of beam energies (30 - 50 keV) and currents to characterize the behavior of the ion source and extraction optics. Emittance scanner data is used to calculate the beam trace-space distribution and corresponding transverse emittance. If the plasma density is changing during a beam pulse, time-resolved emittance scanner data has been taken to study the corresponding evolution of the beam trace-space distribution.

  8. Histology shows that elongated neck ribs in sauropod dinosaurs are ossified tendons.

    PubMed

    Klein, Nicole; Christian, Andreas; Sander, P Martin

    2012-12-23

    The histology of cervical ribs of Sauropoda reveals a primary bone tissue, which largely consists of longitudinally oriented mineralized collagen fibres, essentially the same tissue as found in ossified tendons. The absence of regular periosteal bone and the dominance of longitudinal fibres contradict the ventral bracing hypothesis (VBH) postulated for sauropod necks. The VBH predicts histologically primary periosteal bone with fibres oriented perpendicular to the rib long axis, indicative of connective tissue between overlapping hyperelongated cervical ribs. The transformation of the cervical ribs into ossified tendons makes the neck more flexible and implies that tension forces acted mainly along the length of the neck. This is contrary to the VBH, which requires compressive forces along the neck. Tension forces would allow important neck muscles to shift back to the trunk region, making the neck much lighter.

  9. Histology shows that elongated neck ribs in sauropod dinosaurs are ossified tendons

    PubMed Central

    Klein, Nicole; Christian, Andreas; Sander, P. Martin

    2012-01-01

    The histology of cervical ribs of Sauropoda reveals a primary bone tissue, which largely consists of longitudinally oriented mineralized collagen fibres, essentially the same tissue as found in ossified tendons. The absence of regular periosteal bone and the dominance of longitudinal fibres contradict the ventral bracing hypothesis (VBH) postulated for sauropod necks. The VBH predicts histologically primary periosteal bone with fibres oriented perpendicular to the rib long axis, indicative of connective tissue between overlapping hyperelongated cervical ribs. The transformation of the cervical ribs into ossified tendons makes the neck more flexible and implies that tension forces acted mainly along the length of the neck. This is contrary to the VBH, which requires compressive forces along the neck. Tension forces would allow important neck muscles to shift back to the trunk region, making the neck much lighter. PMID:23034173

  10. Preoperative Embolization in Surgical Treatment of a Primary Hemangiopericytoma of the Rib : A Case Report

    PubMed Central

    Akan, Huseyin; Baris, Sancar; Atici, Atilla G.; Uzun, Oguz; Erkan, Levent

    2005-01-01

    Primary hemangiopericytoma of the rib is extremely rare and only a few cases have been reported. A 62-yr-old man presented with an aching chest pain and dyspnea. Thoracic computed tomography revealed a homogenous mass expanding the right seventh rib. A diagnosis of hemangiopericytoma was established by percutaneous needle biopsy. Preoperative embolization of the feeding vessels of the tumor was performed in order to prevent perioperative bleeding. There was no significant bleeding during the surgery, where complete resection of the tumor with 7th to 9th ribs with a surgical margin of 5 cm was performed. Postoperative course was uneventful and there has been no recurrence for thirteen months. To our knowledge, there has been no report to apply a preoperative embolization of a primary hemangiopericytoma of the rib. PMID:15832008

  11. Daylighting and shuttering: RIB system mechanical design and preliminary performance data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinney, L.; Reynolds, D.

    1983-12-01

    The Reflective, Insulating Blind (RIB) system is a flexible, user-controlled daylighting device which also has direct thermal advantages: it can reject a considerable portion of summer sun while still retaining an adequate daylighting function; and it functions as moveable insulation to significantly decrease thermal losses through fenestration during evening hours. The conceptual design of the RIB system was accomplished by Barnes and Shapira at the Oak Ridge National Laboratory (ORNL). Mechanical design and prototype fabrication was accomplished by the authors and 29 systems were installed immediately inside existing south-facing windows of an energy-efficient office and dormitory at ORNL. The buildingmore » is a heavily-instrumented, passively-solar-heated structure for which reliable performance data was gathered and analyzed before the addition of RIB systems, thus facilitating the interpretation of ''after RIB'' performance data.« less

  12. Operative Fixation of Rib Fractures Indications, Techniques, and Outcomes.

    PubMed

    Galos, David; Taylor, Benjamin; McLaurin, Toni

    2017-01-01

    Rib fractures are extremely common injuries and vary in there severity from single nondisplaced fractures to multiple segmental fractures resulting in flail chest and respiratory compromise. Historically, rib fractures have been treated conservatively with pain control and respiratory therapy. However this method may not be the best treatment modality in all situations. Operative fixation of select rib fractures has been increasing in popularity especially in patients with flail chest and respiratory compromise. Newer techniques use muscle sparing approaches and precontoured locking plate technology to obtain stable fixation and allow improved respiration. Current reports shows that rib fracture fixation offers the benefits of improved respiratory mechanics and improved pain control in the severe chest wall injury with resultant improvement in patient outcomes by decreasing time on the ventilator, time in the intensive care unit, and overall hospital length of stay.

  13. Biosorbable poly-L-lactide rib-connecting pins may reduce acute pain after thoracotomy.

    PubMed

    Iwasaki, A; Hamatake, D; Shirakusa, T

    2004-02-01

    Conventional thoracotomy is currently used as a standard procedure, and is often required to treat numerous diseases. Additionally, rib resections are occasionally required to maintain an adequate field of view for surgery. The benefits of using rib pins for chest closure following such procedures have not yet been established. This study sought to evaluate the usefulness of rib pins in reducing acute postoperative pain. Thirty-three consecutive patients with lung cancer underwent lobectomies using the posterolateral approach. The patients were rib-resected and reconstructed with two techniques: 21 patients with absorbable rib pins (ARP group) and 12 patients by ligation with absorbable sutures (LAS group). Intensity of pain was assessed during the 3 days immediately following surgery. The two groups were assessed using the visual analogue scale (VAS) as a pain scale, amounts consumed of patient-controlled analgesics (PCA), and additional chest x-rays. On the first day following surgery, the mean VAS intensity of the ARP group for patient motion was 2.71 +/- 2.14, compared to 5.33 +/- 2.99 in the LAS group. After three days, the mean score for the ARP group was 1.98 +/- 1.89, compared to 4.60 +/- 1.97 in the LAS group. Scores in the ARP group were significantly lower than in the LAS group one day and three days following thoracotomy. The LAS group (55.0 +/- 15.9 times) made more frequent requests than the ARP group (16.1 +/- 10.3 times). The PCA requirement was also significantly lower in the ARP group. Excessive derangement of the rib (grade 2) was found in one case (4.7 %) in the ARP group compared to five cases (41.6 %) in the LAS group. Rib shifts were seen in numerous cases in the LAS group compared to the ARP group as measured by chest x-rays. Use of absorbable rib pins reduced postoperative pain and may improve long-term prospects for the post-thoracotomy course.

  14. Use of the S-hook for Pelvic Fixation in Rib-Based Treatment of Early-Onset Scoliosis: A Multicenter Study.

    PubMed

    Ramirez, Norman; Flynn, John M; Smith, John T; Vitale, Michael; Sturm, Peter F; DʼAmato, Charles; Samdani, Amer; Machiavelli, Raul; El-Hawary, Ron

    2015-06-01

    Retrospective review. The purpose of this study was to evaluate how several preoperative variables affect the outcome using the rib-to-pelvis S-hook constructs of a rib-based distraction implant (Vertical Expandable Prosthetic Titanium Rib). Rib-to-pelvis fixation with S-hooks is one of the options for distal anchoring of rib-based distraction growing rod construct to control early-onset spinal deformity. Since the initial report, the indications of pelvic fixation with S-hooks have been extended and modified. This is an institutional review board-approved retrospective study of patients who underwent rib-based growing rod system surgery-rib-to-pelvis construct with Dunn-McCarthy S-hook. Data evaluation included history, physical examination, preoperative and postoperative radiographs, surgical variables, and complications. Sixty-five patients were evaluated; 38 were male and 27 were female. Mean age at initial procedure was 71 months. The mean follow-up was 46 months. There was a statistically significant improvement of the immediate postoperative Cobb angle and the last follow-up Cobb angle (P < 0.0001). Fifty percent of the patients (32/65) had S-hook-related complications. The most common complication was sliding of the S-hook out of the iliac crest, followed by infection, neuropathic pain, distal migration of more than 2 cm, fracture of the hook, and bursitis. The complications were related to the preoperative ambulatory status, the use of end-to-end rod connectors, surgical time, and not positioning the hook over the central one-third of the iliac crest at the initial implantation. The use of the S-hook as a pelvic attachment of the rib-based system is indicated in nonambulatory patients with progressive, early-onset scoliosis curve with a lack of adequate anchor at the lumbar spine. Several technical factors should be considered to reduce the complication rate. 3.

  15. The costal skeleton of the Regourdou 1 Neandertal.

    PubMed

    Gómez-Olivencia, Asier; Holliday, Trenton; Madelaine, Stéphane; Couture-Veschambre, Christine; Maureille, Bruno

    2018-02-26

    The morphology and size of the Neandertal thorax is a subject of growing interest due to its link to general aspects of body size and shape, including physiological aspects related to bioenergetics and activity budgets. However, the number of well-preserved adult Neandertal costal remains is still low. The recent finding of new additional costal remains from the Regourdou 1 (R1) skeleton has rendered this skeleton as one of the most complete Neandertal costal skeletons with a minimum of 18 ribs represented, five of which are complete or virtually complete. Here we describe for the first time all the rib remains from R1 and compare them to a large modern Euroamerican male sample as well as to other published Neandertal individuals. The costal skeleton of this individual shows significant metric and morphological differences from our modern human male comparative sample. The perceived differences include: dorsoventrally large 1st and 2nd ribs, 3rd ribs with a very closed dorsal curvature and large maximum diameters at the posterior angle, a large tubercle-iliocostal line distance in the 4th rib, thick shafts at the dorsal end of its 6th ribs, thick mid-shafts of the 8th ribs, large articular tubercles at the 9th ribs, and thick shafts of the 11th and 12th ribs. Here we also describe a new mesosternal fragment: the left lateral half of sternebral segments 4 and 5. This portion reveals that the mesosternum of R1 had a sternal foramen in its inferiormost preserved sternal segment and supports previous estimation of the total length of this mesosternum. The new costal remains from R1 support the view that Neandertals, when compared with modern humans, show a significantly different thorax, consistent with differences found in other anatomical regions such as the vertebral column and pelvis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Atmospheric Radiation Measurement Program facilities newsletter, July 2000.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisterson, D. L.; Holdridge, D. J., ed.

    2000-08-03

    For improved safety in and around the ARM SGP CART site, the ARM Program recently purchased and installed an aircraft detection radar system at the central facility near Lamont, Oklahoma. The new system will enhance safety measures already in place at the central facility. The SGP CART site, especially the central facility, houses several instruments employing laser technology. These instruments are designed to be eye-safe and are not a hazard to personnel at the site or pilots of low-flying aircraft over the site. However, some of the specialized equipment brought to the central facility by visiting scientists during scheduled intensivemore » observation periods (IOPs) might use higher-power laser beams that point skyward to make measurements of clouds or aerosols in the atmosphere. If these beams were to strike the eye of a person in an aircraft flying above the instrument, damage to the person's eyesight could result. During IOPs, CART site personnel have obtained Federal Aviation Administration (FAA) approval to temporarily close the airspace directly over the central facility and keep aircraft from flying into the path of the instrument's laser beam. Information about the blocked airspace is easily transmitted to commercial aircraft, but that does not guarantee that the airspace remains completely plane-free. For this reason, during IOPs in which non-eye-safe lasers were in use in the past, ARM technicians watched for low-flying aircraft in and around the airspace over the central facility. If the technicians spotted such an aircraft, they would manually trigger a safety shutter to block the laser beam's path skyward until the plane had cleared the area.« less

  17. Isolated Traumatic Bilateral First Rib Fracture: A Rare Entity

    PubMed Central

    Chatterjee, Souvik; Dey, Rajesh; Ray, Ramdip; Sinha, Santanu

    2011-01-01

    Since the first rib is protected very well by the overlying soft tissue and bones, its fracture is a major injury and a considerable force is required to do it. Therefore, an isolated fracture of this rib is unusual. A 28-year-old healthy female had an accident while crossing the road and a heavy object fell on her. She had severe pain behind her clavicle region and was immediately hospitalized and examined. Thorough clinical examination and different relevant investigations surprisingly disclosed isolated bilateral first rib fracture which is a very rare clinical condition. PMID:25191390

  18. CONSTRUCTION OF NUCLEAR FUEL ELEMENTS

    DOEpatents

    Weems, S.J.

    1963-09-24

    >A rib arrangement and an end construction for nuclearfuel elements laid end to end in a coolant tube are described. The rib arrangement is such that each fuel element, when separated from other fuel elements, fits loosely in the coolant tube and so can easily be inserted or withdrawn from the tube. The end construction of the fuel elements is such that the fuel elements when assembled end to end are keyed against relative rotation, and the ribs of each fuel element cooperate with the ribs of the adjacent fuel elements to give the assembled fuel elements a tight fit with the coolant tube. (AEC)

  19. Significance of Rib Fractures Potentially Caused by Blunt Impact Non Lethal Weapons

    DTIC Science & Technology

    2017-03-01

    Center Drive Alexandria, Virginia 22311-1882 I N S T I T U T E F O R D E F E N S E A N A L Y S E S Significance of Rib Fractures Potentially...F E N S E A N A L Y S E S IDA Document D-8277 Significance of Rib Fractures Potentially Caused by Blunt-Impact Non-Lethal Weapons Shelley M. Cazares...deterrent by inducing pain or muscle spasm at the site of impact of the affected individual. These weapons may induce rib fractures —the focus of this

  20. Beam brilliance investigation of high current ion beams at GSI heavy ion accelerator facility.

    PubMed

    Adonin, A A; Hollinger, R

    2014-02-01

    In this work the emittance measurements of high current Ta-beam provided by VARIS (Vacuum Arc Ion Source) ion source are presented. Beam brilliance as a function of beam aperture at various extraction conditions is investigated. Influence of electrostatic ion beam compression in post acceleration gap on the beam quality is discussed. Use of different extraction systems (single aperture, 7 holes, and 13 holes) in order to achieve more peaked beam core is considered. The possible ways to increase the beam brilliance are discussed.

Top