Beating HF waves to generate VLF waves in the ionosphere
NASA Astrophysics Data System (ADS)
Kuo, Spencer; Snyder, Arnold; Kossey, Paul; Chang, Chia-Lie; Labenski, John
2012-03-01
Beat-wave generation of very low frequency (VLF) waves by two HF heaters in the ionosphere is formulated theoretically and demonstrated experimentally. The heater-induced differential thermal pressure force and ponderomotive force, which dominate separately in the D and F regions of the ionosphere, drive an electron current for the VLF emission. A comparison, applying appropriate ionospheric parameters shows that the ponderomotive force dominates in beat-wave generation of VLF waves. Three experiments, one in the nighttime in the absence of D and E layers and two in the daytime in the presence of D and E layers, were performed. X mode HF heaters of slightly different frequencies were transmitted at CW full power. VLF waves at 10 frequencies ranging from 3.5 to 21.5 kHz were generated. The frequency dependencies of the daytime and nighttime radiation intensities are quite similar, but the nighttime radiation is much stronger than the daytime one at the same radiation frequency. The intensity ratio is as large as 9 dB at 11.5 kHz. An experiment directly comparing VLF waves generated by the beat-wave approach and by the amplitude modulation (AM) approach was also conducted. The results rule out the likely contribution of the AM mechanism acting on the electrojet and indicate that beat-wave in the VLF range prefers to be generated in the F region of the ionosphere through the ponderomotive nonlinearity, consistent with the theory. In the nighttime experiment, the ionosphere was underdense to the HF heaters, suggesting a likely setting for effective beat-wave generation of VLF waves by the HF heaters.
VLF wave generation by beating of two HF waves in the ionosphere
NASA Astrophysics Data System (ADS)
Kuo, Spencer; Snyder, Arnold; Kossey, Paul; Chang, Chia-Lie; Labenski, John
2011-05-01
Theory of a beat-wave mechanism for very low frequency (VLF) wave generation in the ionosphere is presented. The VLF current is produced by beating two high power HF waves of slightly different frequencies through the nonlinearity and inhomogeneity of the ionospheric plasma. Theory also shows that the density irregularities can enhance the beat-wave generation. An experiment was conducted by transmitting two high power HF waves of 3.2 MHz and 3.2 MHz + f, where f = 5, 8, 13, and 2.02 kHz, from the HAARP transmitter. In the experiment, the ionosphere was underdense to the O-mode heater, i.e., the heater frequency f0 > foF2, and overdense or slightly underdense to the X-mode heater, i.e., f0 < fxF2 or f0 ≥ fxF2. The radiation intensity increased with the VLF wave frequency, was much stronger with the X-mode heaters, and was not sensitive to the electrojet. The strongest VLF radiation of 13 kHz was generated when the reflection layer of the X-mode heater was just slightly below the foF2 layer and the spread of the O-mode sounding echoes had the largest enhancement, suggesting an optimal setting for beat-wave generation of VLF waves by the HF heaters.
Laser Beat-Wave Magnetization of a Dense Plasma
NASA Astrophysics Data System (ADS)
Yates, Kevin; Hsu, Scott; Montgomery, David; Dunn, John; Langendorf, Samuel; Pollock, Bradley; Johnson, Timothy; Welch, Dale; Thoma, Carsten
2017-10-01
We present results from the first of a series of experiments to demonstrate and characterize laser beat-wave magnetization of a dense plasma, motivated by the desire to create high-beta targets with standoff for magneto-inertial fusion. The experiments are being conducted at the Jupiter Laser Facility (JLF) at LLNL. The experiment uses the JLF Janus 1 ω (1053 nm) beam and a standalone Nd:YAG (1064 nm) to drive the beat wave, and the Janus 2 ω (526.5 nm) beam to ionize/heat a gas-jet target as well as to provide Thomson-scattering (TS) measurements of the target density/temperature and scattered light from the beat wave. Streaked TS data captured electron-plasma-wave and ion-acoustic-wave features utilizing either nitrogen or helium gas jets. Effects of initial gas density as well as laser intensity on target have been measured, with electron densities ranging from 1E18 to 1E19 cm-3 with temperatures of tens to hundreds of eV, near the desired range for optimal field generation. LSP simulations were run to aid experimental design and data interpretation. LANL LDRD Program.
Investigation of ELF/VLF waves created by a "beat-wave" HF ionospheric heating at high latitudes
NASA Astrophysics Data System (ADS)
Shumilov, Oleg; Tereshchenko, Evgeniy; Kasatkina, Elena; Gomonov, Alexandr
2015-04-01
The generation of extremely low frequency (ELF, 3-3000 Hz) and very low frequency (VLF, 3-30 kHz) electromagnetic waves by modulated ionospheric high frequency (HF, 2-30 MHz) heating is one of the main directions of ionospheric modification experiments. In this work, we present observations of ELF waves generated during a "beat-wave" heating experiments at the EISCAT heating facility. ELF waves were registered with the ELF receiver located at Lovozero (68 N, 35 E), 660 km east from the EISCAT Tromso heating facility (69.6 N, 19.2 E). Frequency shifts between the generated beat-wave and received ELF waves were detected in all sessions. It is shown that the amplitudes of ELF waves depend on the auroral electrojet current strength. Our results showing a strong dependence of ELF signal intensities on the substorm development seem to support the conclusion that electrojet currents may affect the BW generation of ELF/VLF waves.
Stimulated Parametric Decay of Large Amplitude Alfv'en waves in the Large Plasma Device (LaPD)
NASA Astrophysics Data System (ADS)
Dorfman, S.; Carter, T.; Pribyl, P.; Tripathi, S. K. P.; van Compernolle, B.; Vincena, S.
2012-10-01
Alfv'en waves, the fundamental mode of magnetized plasmas, are ubiquitous in lab and space. While the linear behaviour of these waves has been extensively studied, non-linear effects are important in many real systems. In particular, a parametric decay process in which a large amplitude Alfv'en wave decays into an ion acoustic wave and backward propagating Alfv'en wave may be key to the spectrum of solar wind turbulence. The present laboratory experiments aim to stimulate this process by launching counter-propagating Alfv'en waves from antennas placed at either end of the Large Plasma Device (LaPD). The resulting beat response has many properties consistent with an ion acoustic wave including: 1) The beat amplitude peaks when the frequency difference between the two Alfv'en waves is near the value predicted by Alfv'en-ion acoustic wave coupling. 2) This peak beat frequency scales with antenna and plasma parameters as predicted by three wave matching. 3) The beat amplitude peaks at the same location as the magnetic field from the Alfv'en waves. 4) The beat wave is carried by the ions and propagates in the direction of the higher-frequency Alfv'en wave. Strong damping observed after the pump Alfv'en waves are turned off is under investigation.
Nagashima, Yoshihiko; Oosako, Takuya; Takase, Yuichi; Ejiri, Akira; Watanabe, Osamu; Kobayashi, Hiroaki; Adachi, Yuuki; Tojo, Hiroshi; Yamaguchi, Takashi; Kurashina, Hiroki; Yamada, Kotaro; An, Byung Il; Kasahara, Hiroshi; Shimpo, Fujio; Kumazawa, Ryuhei; Hayashi, Hiroyuki; Matsuzawa, Haduki; Hiratsuka, Junichi; Hanashima, Kentaro; Kakuda, Hidetoshi; Sakamoto, Takuya; Wakatsuki, Takuma
2010-06-18
We present an observation of beat oscillation generation by coupled modes associated with parametric decay instability (PDI) during radio frequency (rf) wave heating experiments on the Tokyo Spherical Tokamak-2. Nearly identical PDI spectra, which are characterized by the coexistence of the rf pump wave, the lower-sideband wave, and the low-frequency oscillation in the ion-cyclotron range of frequency, are observed at various locations in the edge plasma. A bispectral power analysis was used to experimentally discriminate beat oscillation from the resonant mode for the first time. The pump and lower-sideband waves have resonant mode components, while the low-frequency oscillation is exclusively excited by nonlinear coupling of the pump and lower-sideband waves. Newly discovered nonlocal transport channels in spectral space and in real space via PDI are described.
NASA Astrophysics Data System (ADS)
Varma, Ram K.; Punithavelu, A. M.; Banerjee, S. B.
2002-02-01
We report here the observations that exhibit the existence of matter wave phenomena with wavelength in the macrodomain of a few centimeters, for electrons moving along a magnetic field from an electron gun to a collector plate situated behind a grounded grid. These are in accordance with the predictions of a quantumlike theory for charged particles in the classical macrodomain, given by one of the authors [R. K. Varma, Phys. Rev. A 31, 3951 (1985)] with a recent generalization [R. K. Varma, Phys. Rev. E 64, 036608 (2001)]. The beats correspond to two closely spaced ``frequencies'' in the system, with the beat frequency given, in accordance with the characteristics of a wave phenomena, by the difference between the two frequencies. The beats ride as a modulation over a discrete energy band structure obtained with only one frequency present. The frequency here corresponds to the distance between the electron gun and the detector plate as it characterizes the variation in the energy band structure as the electron energy is swept. The second ``frequency'' corresponds to the gun-grid distance. These observations of the beats of matter waves in this experiment, with characteristics in accordance with the wave algorithm, then establish unambiguously the existence of macroscopic matter waves for electrons propagating along a magnetic field.
Nonlinear mixing of electromagnetic waves in plasmas.
Stefan, V; Cohen, B I; Joshi, C
1989-01-27
Recently, a strong research effort has been focused on applications of beat waves in plasma interactions. This research has important implications for various aspects of plasma physics and plasma technology. This article reviews the present status of the field and comments on plasma probing, heating of magnetically confined and laser plasmas, ionospheric plasma modification, beat-wave particle acceleration, beat-wave current drive in toroidal devices, beat wave-driven free-electron lasers, and phase conjugation with beat waves.
Increased beat-to-beat T-wave variability in myocardial infarction patients.
Hasan, Muhammad A; Abbott, Derek; Baumert, Mathias; Krishnan, Sridhar
2018-03-28
The purpose of this study was to investigate the beat-to-beat variability of T-waves (TWV) and to assess the diagnostic capabilities of T-wave-based features for myocardial infarction (MI). A total of 148 recordings of standard 12-lead electrocardiograms (ECGs) from 79 MI patients (22 females, mean age 63±12 years; 57 males, mean age 57±10 years) and 69 recordings from healthy subjects (HS) (17 females, 42±18 years; 52 males, 40±13 years) were studied. For the quantification of beat-to-beat QT intervals in ECG signal, a template-matching algorithm was applied. To study the T-waves beat-to-beat, we measured the angle between T-wave max and T-wave end with respect to Q-wave (∠α) and T-wave amplitudes. We computed the standard deviation (SD) of beat-to-beat T-wave features and QT intervals as markers of variability in T-waves and QT intervals, respectively, for both patients and HS. Moreover, we investigated the differences in the studied features based on gender and age for both groups. Significantly increased TWV and QT interval variability (QTV) were found in MI patients compared to HS (p<0.05). No significant differences were observed based on gender or age. TWV may have some diagnostic attributes that may facilitate identifying patients with MI. In addition, the proposed beat-to-beat angle variability was found to be independent of heart rate variations. Moreover, the proposed feature seems to have higher sensitivity than previously reported feature (QT interval and T-wave amplitude) variability for identifying patients with MI.
Mechanical signaling coordinates the embryonic heartbeat.
Chiou, Kevin K; Rocks, Jason W; Chen, Christina Yingxian; Cho, Sangkyun; Merkus, Koen E; Rajaratnam, Anjali; Robison, Patrick; Tewari, Manorama; Vogel, Kenneth; Majkut, Stephanie F; Prosser, Benjamin L; Discher, Dennis E; Liu, Andrea J
2016-08-09
In the beating heart, cardiac myocytes (CMs) contract in a coordinated fashion, generating contractile wave fronts that propagate through the heart with each beat. Coordinating this wave front requires fast and robust signaling mechanisms between CMs. The primary signaling mechanism has long been identified as electrical: gap junctions conduct ions between CMs, triggering membrane depolarization, intracellular calcium release, and actomyosin contraction. In contrast, we propose here that, in the early embryonic heart tube, the signaling mechanism coordinating beats is mechanical rather than electrical. We present a simple biophysical model in which CMs are mechanically excitable inclusions embedded within the extracellular matrix (ECM), modeled as an elastic-fluid biphasic material. Our model predicts strong stiffness dependence in both the heartbeat velocity and strain in isolated hearts, as well as the strain for a hydrogel-cultured CM, in quantitative agreement with recent experiments. We challenge our model with experiments disrupting electrical conduction by perfusing intact adult and embryonic hearts with a gap junction blocker, β-glycyrrhetinic acid (BGA). We find this treatment causes rapid failure in adult hearts but not embryonic hearts-consistent with our hypothesis. Last, our model predicts a minimum matrix stiffness necessary to propagate a mechanically coordinated wave front. The predicted value is in accord with our stiffness measurements at the onset of beating, suggesting that mechanical signaling may initiate the very first heartbeats.
Ionospheric very low frequency transmitter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuo, Spencer P.
2015-02-15
The theme of this paper is to establish a reliable ionospheric very low frequency (VLF) transmitter, which is also broad band. Two approaches are studied that generate VLF waves in the ionosphere. The first, classic approach employs a ground-based HF heater to directly modulate the high latitude ionospheric, or auroral electrojet. In the classic approach, the intensity-modulated HF heater induces an alternating current in the electrojet, which serves as a virtual antenna to transmit VLF waves. The spatial and temporal variations of the electrojet impact the reliability of the classic approach. The second, beat-wave approach also employs a ground-based HFmore » heater; however, in this approach, the heater operates in a continuous wave mode at two HF frequencies separated by the desired VLF frequency. Theories for both approaches are formulated, calculations performed with numerical model simulations, and the calculations are compared to experimental results. Theory for the classic approach shows that an HF heater wave, intensity-modulated at VLF, modulates the electron temperature dependent electrical conductivity of the ionospheric electrojet, which, in turn, induces an ac electrojet current. Thus, the electrojet becomes a virtual VLF antenna. The numerical results show that the radiation intensity of the modulated electrojet decreases with an increase in VLF radiation frequency. Theory for the beat wave approach shows that the VLF radiation intensity depends upon the HF heater intensity rather than the electrojet strength, and yet this approach can also modulate the electrojet when present. HF heater experiments were conducted for both the intensity modulated and beat wave approaches. VLF radiations were generated and the experimental results confirm the numerical simulations. Theory and experimental results both show that in the absence of the electrojet, VLF radiation from the F-region is generated via the beat wave approach. Additionally, the beat wave approach generates VLF radiations over a larger frequency band than by the modulated electrojet.« less
Mechanical signaling coordinates the embryonic heartbeat
Chiou, Kevin K.; Rocks, Jason W.; Chen, Christina Yingxian; Cho, Sangkyun; Merkus, Koen E.; Rajaratnam, Anjali; Robison, Patrick; Tewari, Manorama; Vogel, Kenneth; Majkut, Stephanie F.; Prosser, Benjamin L.; Discher, Dennis E.; Liu, Andrea J.
2016-01-01
In the beating heart, cardiac myocytes (CMs) contract in a coordinated fashion, generating contractile wave fronts that propagate through the heart with each beat. Coordinating this wave front requires fast and robust signaling mechanisms between CMs. The primary signaling mechanism has long been identified as electrical: gap junctions conduct ions between CMs, triggering membrane depolarization, intracellular calcium release, and actomyosin contraction. In contrast, we propose here that, in the early embryonic heart tube, the signaling mechanism coordinating beats is mechanical rather than electrical. We present a simple biophysical model in which CMs are mechanically excitable inclusions embedded within the extracellular matrix (ECM), modeled as an elastic-fluid biphasic material. Our model predicts strong stiffness dependence in both the heartbeat velocity and strain in isolated hearts, as well as the strain for a hydrogel-cultured CM, in quantitative agreement with recent experiments. We challenge our model with experiments disrupting electrical conduction by perfusing intact adult and embryonic hearts with a gap junction blocker, β-glycyrrhetinic acid (BGA). We find this treatment causes rapid failure in adult hearts but not embryonic hearts—consistent with our hypothesis. Last, our model predicts a minimum matrix stiffness necessary to propagate a mechanically coordinated wave front. The predicted value is in accord with our stiffness measurements at the onset of beating, suggesting that mechanical signaling may initiate the very first heartbeats. PMID:27457951
Stimulated Parametric Decay of Large Amplitude Alfvén waves in the Large Plasma Device (LaPD)
NASA Astrophysics Data System (ADS)
Dorfman, S. E.; Carter, T.; Pribyl, P.; Tripathi, S.; Van Compernolle, B.; Vincena, S. T.
2012-12-01
Alfvén waves, a fundamental mode of magnetized plasmas, are ubiquitous in lab and space. While the linear behaviour of these waves has been extensively studied [1], non-linear effects are important in many real systems, including the solar wind and solar corona. In particular, a parametric decay process in which a large amplitude Alfvén wave decays into an ion acoustic wave and backward propagating Alfvén wave may be key to the spectrum of solar wind turbulence. Ion acoustic waves have been observed in the heliosphere, but their origin and role have not yet been determined [2]. Such waves produced by parametric decay in the corona could contribute to coronal heating [3]. Parametric decay has also been suggested as an intermediate instability mediating the observed turbulent cascade of Alfvén waves to small spatial scales [4]. The present laboratory experiments aim to stimulate the parametric decay process by launching counter-propagating Alfvén waves from antennas placed at either end of the Large Plasma Device (LaPD). The resulting beat response has a dispersion relation consistent with an ion acoustic wave. Also consistent with a stimulated decay process: 1) The beat amplitude peaks when the frequency difference between the two Alfvén waves is near the value predicted by Alfvén-ion acoustic wave coupling. 2) This peak beat frequency scales with antenna and plasma parameters as predicted by three wave matching. 3) The beat amplitude peaks at the same location as the magnetic field from the Alfvén waves. 4) The beat wave is carried by the ions and propagates in the direction of the higher-frequency Alfvén wave. Strong damping observed after the pump Alfvén waves are turned off and observed heating of the plasma by the Alfvén waves are under investigation. [1] W. Gekelman, J. Geophys. Res., 104:14417-14436, July 1999. [2] A. Mangeney,et. al., Annales Geophysicae, Volume 17, Number 3 (1999). [3] F. Pruneti, F and M. Velli, ESA Spec. Pub. 404, 623 (1997). [4] P. Yoon and T. Fang, Plasma Phys. Control. Fusion 50 (2008). This work was performed at UCLA's Basic Plasma Science Facility, which is jointly supported by the U.S. DoE and NSF.
Modeling of Nonlinear Beat Signals of TAE's
NASA Astrophysics Data System (ADS)
Zhang, Bo; Berk, Herbert; Breizman, Boris; Zheng, Linjin
2012-03-01
Experiments on Alcator C-Mod reveal Toroidal Alfven Eigenmodes (TAE) together with signals at various beat frequencies, including those at twice the mode frequency. The beat frequencies are sidebands driven by quadratic nonlinear terms in the MHD equations. These nonlinear sidebands have not yet been quantified by any existing codes. We extend the AEGIS code to capture nonlinear effects by treating the nonlinear terms as a driving source in the linear MHD solver. Our goal is to compute the spatial structure of the sidebands for realistic geometry and q-profile, which can be directly compared with experiment in order to interpret the phase contrast imaging diagnostic measurements and to enable the quantitative determination of the Alfven wave amplitude in the plasma core
Terahertz generation by beating two Langmuir waves in a warm and collisional plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Xiao-Bo; Qiao, Xin; Cheng, Li-Hong
2015-09-15
Terahertz (THz) radiation generated by beating of two Langmuir waves in a warm and collisional plasma is discussed theoretically. The critical angle between the two Langmuir waves and the critical wave-length (wave vector) of Langmuir waves for generating THz radiation are obtained analytically. Furthermore, the maximum radiation energy is obtained. We find that the critical angle, the critical wave-length, and the generated radiation energy strongly depend on plasma temperature and wave-length of the Langmuir waves. That is, the THz radiation generated by beating of two Langmuir waves in a warm and collisional plasma can be controlled by adjusting the plasmamore » temperature and the Langmuir wave-length.« less
1991-01-09
Linacs Duke a NIST/NRL UCSB Accelerator Storage ring race - track Electrostatic microtron Van de Graaf Status 1993 19 9 2 h 1990 Electron Energy 0.5-1... phase velocity slightly less than the electrons. This wave is called the "ponderomotive potential wave", which is generated by the beating of the...c is the speed of light. The beat wave has the same frequency as the radiation, but its wavenumber is k + k,. The phase velocity of the beat wave Vph
Detection of Low-volume Blood Loss: Compensatory Reserve Versus Traditional Vital Signs
2014-01-01
studies have demonstrated that photoplethysmogram (PPG) wave forms obtained with a pulse oximeter sensor significantly change with volume loss.5 With this...donation, including PPG wave forms (OEM III pulse oximeter , Nonin, Minneapolis, MN), and a noninvasive BPwave form (ccNexfin, Edwards Lifesciences, Irvine...a PPG wave form obtained with a pulse oximeter sensor. CRI is calculated after 30 heart beats and is recalculated beat-to-beat in a continuous
The brain responses to different frequencies of binaural beat sounds on QEEG at cortical level.
Jirakittayakorn, Nantawachara; Wongsawat, Yodchanan
2015-01-01
Beat phenomenon is occurred when two slightly different frequency waves interfere each other. The beat can also occur in the brain by providing two slightly different frequency waves separately each ear. This is called binaural beat. The brain responses to binaural beat are in discussion process whether the brain side and the brain area. Therefore, this study aims to figure out the brain responses to binaural beat by providing different binaural beat frequencies on 250 carrier tone continuously for 30 minutes to participants and using quantitative electroencephalography (QEEG) to interpret the data. The result shows that different responses appear in different beat frequency. Left hemisphere dominance occur in 3 Hz beat within 15 minutes and 15 Hz beat within 5 minutes. Right hemisphere dominance occurs in 10 Hz beat within 25 minute. 6 Hz beat enhances all area of the brain within 10 minutes. 8 Hz and 25 Hz beats have no clearly responses while 40 Hz beat enhances the responses in frontal lobe. These brain responses can be used for brain modulation application to induce the brain activity in further studies.
Electron Beam Transport in Advanced Plasma Wave Accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Ronald L
2013-01-31
The primary goal of this grant was to develop a diagnostic for relativistic plasma wave accelerators based on injecting a low energy electron beam (5-50keV) perpendicular to the plasma wave and observing the distortion of the electron beam's cross section due to the plasma wave's electrostatic fields. The amount of distortion would be proportional to the plasma wave amplitude, and is the basis for the diagnostic. The beat-wave scheme for producing plasma waves, using two CO2 laser beam, was modeled using a leap-frog integration scheme to solve the equations of motion. Single electron trajectories and corresponding phase space diagrams weremore » generated in order to study and understand the details of the interaction dynamics. The electron beam was simulated by combining thousands of single electrons, whose initial positions and momenta were selected by random number generators. The model was extended by including the interactions of the electrons with the CO2 laser fields of the beat wave, superimposed with the plasma wave fields. The results of the model were used to guide the design and construction of a small laboratory experiment that may be used to test the diagnostic idea.« less
The fine structure of Langmuir waves observed upstream of the bow shock at Venus
NASA Technical Reports Server (NTRS)
Hospodarsky, G. B.; Gurnett, D. A.; Kurth, W. S.; Kivelson, M. G.; Strangeway, R. J.; Bolton, S. J.
1994-01-01
Highly structured Langmuir waves, also known as electron plasma oscillations, have been observed in the foreshock of Venus using the plasma wave experiment on the Galileo spacecraft during the gravity assist flyby on February 10, 1990. The Galileo wideband sampling system provides digital electric field waveform measurements at sampling rates up to 201,600 samples per second, much higher than any previous instrument of this type. The main Langmuir wave emission band occurs near the local electron plasma frequency, which was approximately 43 kHz. The Langmuir waves are observed to shift above and below the plasma frequency, sometimes by as much as 20 kHz. The shifts in frequency are closely correlated with the downstream distance from the tangent field line, implying that the shifts are controlled by the electron beam velocity. Considerable fine structure is also evident, with time scales as short as 0.15 milliseconds, corresponding to spatial scales of a few tens of Debye lengths. The frequency spectrum often consists of beat-type waveforms, with beat frequencies ranging from 0.2 to 7 kHz, and in a few cases, isolated wavepackets. The peak electric field strengths are approximately 1 mV/m. These field strengths are too small for strongly nonlinear processes to be important. The beat-type waveforms are suggestive of a parametric decay process.
Di Rienzo, M; Vaini, E; Castiglioni, P; Merati, G; Meriggi, P; Parati, G; Faini, A; Rizzo, F
2013-11-01
Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population. Copyright © 2013 Elsevier B.V. All rights reserved.
Floré, Vincent; Willems, Rik
2012-12-01
In this review, we focus on temporal variability of cardiac repolarization. This phenomenon has been related to a higher risk for ventricular arrhythmia and is therefore interesting as a marker of sudden cardiac death risk. We review two non-invasive clinical techniques quantifying repolarization variability: T-wave alternans (TWA) and beat-to-beat variability of repolarization (BVR). We discuss their pathophysiological link with ventricular arrhythmia and the current clinical relevance of these techniques.
The evaluation of phasemeter prototype performance for the space gravitational waves detection.
Liu, He-Shan; Dong, Yu-Hui; Li, Yu-Qiong; Luo, Zi-Ren; Jin, Gang
2014-02-01
Heterodyne laser interferometry is considered as the most promising readout scheme for future space gravitational wave detection missions, in which the gravitational wave signals disguise as small phase variances within the heterodyne beat note. This makes the phasemeter, which extracts the phase information from the beat note, the key device to this system. In this paper, a prototype of phasemeter based on digital phase-locked loop technology is developed, and the major noise sources which may contribute to the noise spectra density are analyzed in detail. Two experiments are also carried out to evaluate the performance of the phasemeter prototype. The results show that the sensitivity is achieved 2π μrad/√Hz in the frequency range of 0.04 Hz-10 Hz. Due to the effect of thermal drift, the noise obviously increases with the frequencies down to 0.1 mHz.
The evaluation of phasemeter prototype performance for the space gravitational waves detection
NASA Astrophysics Data System (ADS)
Liu, He-Shan; Dong, Yu-Hui; Li, Yu-Qiong; Luo, Zi-Ren; Jin, Gang
2014-02-01
Heterodyne laser interferometry is considered as the most promising readout scheme for future space gravitational wave detection missions, in which the gravitational wave signals disguise as small phase variances within the heterodyne beat note. This makes the phasemeter, which extracts the phase information from the beat note, the key device to this system. In this paper, a prototype of phasemeter based on digital phase-locked loop technology is developed, and the major noise sources which may contribute to the noise spectra density are analyzed in detail. Two experiments are also carried out to evaluate the performance of the phasemeter prototype. The results show that the sensitivity is achieved 2π μrad/√Hz in the frequency range of 0.04 Hz-10 Hz. Due to the effect of thermal drift, the noise obviously increases with the frequencies down to 0.1 mHz.
Boskovski, Marko T; Shmuylovich, Leonid; Kovács, Sándor J
2008-12-01
The new echocardiography-based, load-independent index of diastolic filling (LIIDF) M was assessed using load-/shape-varying E-waves after premature ventricular contractions (PVCs). Twenty-six PVCs in 15 subjects from a preexisting simultaneous echocardiography-catheterization database were selected. Perturbed load-state beats, defined as the first two post-PVC E-waves, and steady-state E-waves, were subjected to conventional and model-based analysis. M, a dimensionless index, defined by the slope of the peak driving-force vs. peak (filling-opposing) resistive-force regression, was determined from steady-state E-waves alone, and from load-perturbed E-waves combined with a matched number of subsequent beats. Despite high degrees of E-wave shape variation, M derived from load-varying, perturbed beats and M derived from steady-state beats alone were indistinguishable. Because the peak driving-force vs. peak resistive-force relation determining M remains highly linear in the extended E-wave shape and load variation regime observed, we conclude that M is a robust LIIDF.
Model for the heart beat-to-beat time series during meditation
NASA Astrophysics Data System (ADS)
Capurro, A.; Diambra, L.; Malta, C. P.
2003-09-01
We present a model for the respiratory modulation of the heart beat-to-beat interval series. The model consists of a pacemaker, that simulates the membrane potential of the sinoatrial node, modulated by a periodic input signal plus correlated noise that simulates the respiratory input. The model was used to assess the waveshape of the respiratory signals needed to reproduce in the phase space the trajectory of experimental heart beat-to-beat interval data. The data sets were recorded during meditation practices of the Chi and Kundalini Yoga techniques. Our study indicates that in the first case the respiratory signal has the shape of a smoothed square wave, and in the second case it has the shape of a smoothed triangular wave.
NASA Astrophysics Data System (ADS)
Shi, Zhi-Dong; Lin, Jian-Qiang; Bao, Huan-Huan; Liu, Shu; Xiang, Xue-Nong
2008-03-01
A photoelectric measurement system for measuring the beat length of birefringence fiber is set up including a set of rotating-wave-plate polarimeter using single photodiode. And two improved cutback methods suitable for measuring beat-length within millimeter range of high birefringence fiber are proposed through data processing technique. The cut length needs not to be restricted shorter than one centimeter so that the auto-cleaving machine is freely used, and no need to carefully operate the manually cleaving blade with low efficiency and poor success. The first method adopts the parameter-fitting to a saw-tooth function of tried beat length by the criterion of minimum square deviations, without special limitation on the cut length. The second method adopts linear-fitting in the divided length ranges, only restrict condition is the increment between different cut lengths less than one beat-length. For a section of holey high-birefringence fiber, we do experiments respectively by the two methods. The detecting error of beat-length is discussed and the advantage is compared.
NASA Astrophysics Data System (ADS)
Dorfman, S. E.; Carter, T. A.; Pribyl, P.; Tripathi, S.; Van Compernolle, B.; Vincena, S. T.; Sydora, R. D.
2013-12-01
Alfvén waves, a fundamental mode of magnetized plasmas, are ubiquitous in space plasmas. While the linear behavior of these waves has been extensively studied [1], non-linear effects are important in many real systems, including the solar corona and solar wind. In particular, a parametric decay process in which a large amplitude Alfvén wave decays into an ion acoustic wave and backward propagating Alfvén wave may play an important role in the coronal heating problem. Specifically, the decay of large-amplitude Alfvén waves propagating outward from the photosphere could lead to heating of the corona by the daughter ion acoustic modes [2]. As direct observational evidence of parametric decay is limited [3], laboratory experiments may play an important role in validating simple theoretical predictions and aiding in the interpretation of space measurements. Recent counter-propagating Alfvén wave experiments in the Large Plasma Device (LAPD) have recorded the first laboratory observation of the Alfvén-acoustic mode coupling at the heart of this parametric decay instability [4]. A resonance in the beat wave response produced by the two launched Alfvén waves is observed and is identified as a damped ion acoustic mode based on the measured dispersion relation. Other properties of the interaction including the spatial profile of the beat mode and response amplitude are also consistent with theoretical predictions for a three-wave interaction driven by a nonlinear ponderomotive force. Strong damping observed after the pump Alfvén waves are turned off is under investigation; a novel ion acoustic wave launcher is under development to launch the mode directly for damping studies. New experiments also aim to identify decay instabilities from a single large-amplitude Alfvén wave. In conjunction with these experiments, gyrokinetic simulation efforts are underway to scope out the relevant parameter space. [1] W. Gekelman, et. al., Phys. Plasmas 18, 055501 (2011). [2] F. Pruneti, F and M. Velli, ESA Spec. Pub. 404, 623 (1997). [3] S. R. Spangler, et. al., Phys. Plasmas 4, 846 (1997). [4] S. Dorfman and T. Carter, Phys. Rev. Lett. 110, 195001 (2013).
NASA Astrophysics Data System (ADS)
Xue, Shan; Du, Hongchuan; Hu, Bitao; Lin, C. D.; Le, Anh-Thu
2018-04-01
We reexamine the recent pump-probe experiment with O2 using short intense infrared laser pulses theoretically. Using parameters that closely mimic the experimental conditions and taking into account the angle-dependent population redistribution due to resonant coupling between the relevant states, we show that the observed kinetic energy release spectra, including the energy-dependent structure and the quantum beat frequencies, can be accurately reproduced. Our results reveal additional important channels that were missed earlier. In particular, the strong contributions from O2+a 4Πu and b 4Σg- states lead to the possibility of observing the interchannel beating. We further demonstrate that, by varying the laser parameters, the coherent nuclear wave-packet motions on different potential energy surfaces (PESs) can be probed and the properties of the PES can be examined. Future experiments with different wavelength lasers are proposed for better probing and controlling nuclear dynamics on different PESs.
Kamoi, Shun; Pretty, Christopher; Balmer, Joel; Davidson, Shaun; Pironet, Antoine; Desaive, Thomas; Shaw, Geoffrey M; Chase, J Geoffrey
2017-04-24
Pressure contour analysis is commonly used to estimate cardiac performance for patients suffering from cardiovascular dysfunction in the intensive care unit. However, the existing techniques for continuous estimation of stroke volume (SV) from pressure measurement can be unreliable during hemodynamic instability, which is inevitable for patients requiring significant treatment. For this reason, pressure contour methods must be improved to capture changes in vascular properties and thus provide accurate conversion from pressure to flow. This paper presents a novel pressure contour method utilizing pulse wave velocity (PWV) measurement to capture vascular properties. A three-element Windkessel model combined with the reservoir-wave concept are used to decompose the pressure contour into components related to storage and flow. The model parameters are identified beat-to-beat from the water-hammer equation using measured PWV, wave component of the pressure, and an estimate of subject-specific aortic dimension. SV is then calculated by converting pressure to flow using identified model parameters. The accuracy of this novel method is investigated using data from porcine experiments (N = 4 Pietrain pigs, 20-24.5 kg), where hemodynamic properties were significantly altered using dobutamine, fluid administration, and mechanical ventilation. In the experiment, left ventricular volume was measured using admittance catheter, and aortic pressure waveforms were measured at two locations, the aortic arch and abdominal aorta. Bland-Altman analysis comparing gold-standard SV measured by the admittance catheter and estimated SV from the novel method showed average limits of agreement of ±26% across significant hemodynamic alterations. This result shows the method is capable of estimating clinically acceptable absolute SV values according to Critchely and Critchely. The novel pressure contour method presented can accurately estimate and track SV even when hemodynamic properties are significantly altered. Integrating PWV measurements into pressure contour analysis improves identification of beat-to-beat changes in Windkessel model parameters, and thus, provides accurate estimate of blood flow from measured pressure contour. The method has great potential for overcoming weaknesses associated with current pressure contour methods for estimating SV.
Effects of intra-aortic counterpulsation on aortic wall energetics and damping: in vivo experiments.
Fischer, Edmundo I Cabrera; Bia, Daniel; Camus, Juan M; Zócalo, Yanina; de Forteza, Eduardo; Armentano, Ricardo L
2008-01-01
Intra-aortic balloon pumping (IABP) could modify the arterial biomechanics; however, its effects on arterial wall properties have not been fully explored. This dynamical study was designed to characterize the pressure-dependent and smooth muscle-dependent effects of IABP on aortic wall energetics in an in vivo animal model. Intra-aortic balloon pumping (1:2) was performed in six anesthetized sheep in which aortic pressure and diameter signals were measured in basal, augmented (during balloon inflation), and assisted (postaugmented) beats. Energy dissipation values in augmented and assisted beats were significantly higher than those observed in basal state (p < 0.05). Assisted beats showed a significant increase of wall damping with respect to basal and augmented beats (p < 0.05). Intra-aortic balloon pumping resulted in a significant increase of pulse wave velocity (p < 0.05) in augmented beats with respect to basal state (6.3 +/- 0.8 vs. 5.2 +/- 0.5 m x s(-1)); whereas values observed in assisted beats were significantly (p < 0.05) lower than those observed in augmented beats (4.9 +/- 0.5 vs. 6.3 +/- 0.8 m x s(-1)). Our findings show that IABP determined the pressure and smooth muscle-dependent changes in arterial wall energetics and damping properties in this animal model.
Dynamics of High Temperature Plasmas.
1985-10-01
25 VI. > LASER BEAT WAVE PARTICLE ACCELERATION-.. ..... .. 27 ,, VII. ORBITRON MASER DESIGN .. ..... ............. 30 0 VIIM> ELECTRON BEAM STABILITY...IN THE MODIFIED BETATRON .... ............ 32 IX. * RELATIVISTIC ELECTRON BEAM DIODE DESIGN . . . . 35 X. FREE ELECTRON LASER APPLICATION TO XUV...Accelerators (B), VI. Laser Beat Wave Particle Acceleration, VII. Orbitron Maser Design , VIII. Electron Beam Stability in the Modified Betatron, IX
Phase Shifting and the Beating of Complex Waves
ERIC Educational Resources Information Center
Keeports, David
2011-01-01
At the introductory level, the demonstration and analysis of sound beating is usually limited to the superposition of two purely sinusoidal waves with equal amplitudes and very similar frequencies. Under such conditions, an observer hears the periodic variation of the loudness of a sound with an unchanging timbre. On the other hand, when complex…
Observation of Quantum Beating in rb at 2.1 THz and 18.2 THz: Long-Range Rb^{*}-Rb Interactions.
NASA Astrophysics Data System (ADS)
Goldshlag, William; Ricconi, Brian J.; Eden, J. Gary
2017-06-01
The interaction of Rb 7s ^{2}S_{1/2}, 5d ^{2}D_{3/2,5/2} and 5p ^{2}P_{3/2} atoms with the background species at long range (100-1000Å) has been observed by pump-probe ultrafast laser spectroscopy. Parametric four-wave mixing in Rb vapor with pairs of 50-70 fs pulses produces coherent Rb 6P-5S emission at 420 nm that is modulated by Rb quantum beating. The two dominant beating frequencies are 18.2 THz and 2.07 THz, corresponding to quantum beating between 7S and 5D states and to the (5D-5P_{3/2})-(5P_{3/2}-5S) defect, respectively. Analysis of Rabi oscillations in these pump-probe experiments allows for the mean interaction energy at long range to be determined. The figure shows Fourier transform spectra of representative Rabi oscillation waveforms. The waveform and spectrum at left illustrate quantum beating in Rb at 2.1 THz. The spectrum at right is dominated by the 18.2 THz frequency component generated by 7S-5D beating in Rb. Insets show respective temporal behaviors of the 6P-5S line near the coherent transient (zero interpulse delay).
Wei, Fang-Fei; Li, Yan; Zhang, Lu; Xu, Ting-Yan; Ding, Feng-Hua; Wang, Ji-Guang; Staessen, Jan A
2014-04-01
Whether target organ damage is associated with blood pressure (BP) variability independent of level remains debated. We assessed these associations from 10-minute beat-to-beat, 24-hour ambulatory, and 7-day home BP recordings in 256 untreated subjects referred to a hypertension clinic. BP variability indices were variability independent of the mean, maximum-minimum difference, and average real variability. Effect sizes (standardized β) were computed using multivariable regression models. In beat-to-beat recordings, left ventricular mass index (n=128) was not (P≥0.18) associated with systolic BP but increased with all 3 systolic variability indices (+2.97-3.53 g/m(2); P<0.04); the urinary albumin-to-creatinine ratio increased (P≤0.03) with systolic BP (+1.14-1.17 mg/mmol) and maximum-minimum difference (+1.18 mg/mmol); and pulse wave velocity increased with systolic BP (+0.69 m/s; P<0.001). In 24-hour recordings, all 3 indices of organ damage increased (P<0.03) with systolic BP, whereas the associations with BP variability were nonsignificant (P≥0.15) except for increases in pulse wave velocity (P<0.05) with variability independent of the mean (+0.16 m/s) and maximum-minimum difference (+0.17 m/s). In home recordings, the urinary albumin-to-creatinine ratio (+1.27-1.30 mg/mmol) and pulse wave velocity (+0.36-0.40 m/s) increased (P<0.05) with systolic BP, whereas all associations of target organ damage with the variability indices were nonsignificant (P≥0.07). In conclusion, while accounting for BP level, associations of target organ damage with BP variability were readily detectable in beat-to-beat recordings, least noticeable in home recordings, with 24-hour ambulatory monitoring being informative only for pulse wave velocity.
Free-electron laser from wave-mechanical beats of 2 electron beams
NASA Technical Reports Server (NTRS)
Lichtenstein, R. M.
1982-01-01
It is possible, though technically difficult, to produce beams of free electrons that exhibit beats of a quantum mechanical nature. (1) the generation of electromagnetic radiation, e.g., light, based on the fact that the beats give rise to alternating charge and current densities; and a frequency shifter, based on the fact that a beam with beats constitutes a moving grating. When such a grating is exposed to external radiation of suitable frequency and direction, the reflected rediation will be shifted in frequency, since the grating is moving. A twofold increase of the frequency is readily attainable. It is shown that it is impossible to generate radiation, because the alternating electromagnetic fields that accompany the beats cannot reform themselves into freely propagating waves. The frequency shifter is useless as a practical device, because its reflectance is extremely low for realizable beams.
Nonlinear beat excitation of low frequency wave in degenerate plasmas
NASA Astrophysics Data System (ADS)
Mir, Zahid; Shahid, M.; Jamil, M.; Rasheed, A.; Shahbaz, A.
2018-03-01
The beat phenomenon due to the coupling of two signals at slightly different frequencies that generates the low frequency signal is studied. The linear dispersive properties of the pump and sideband are analyzed. The modified nonlinear dispersion relation through the field coupling of linear modes against the beat frequency is derived in the homogeneous quantum dusty magnetoplasmas. The dispersion relation is used to derive the modified growth rate of three wave parametric instability. Moreover, significant quantum effects of electrons through the exchange-correlation potential, the Bohm potential, and the Fermi pressure evolved in macroscopic three wave interaction are presented. The analytical results are interpreted graphically describing the significance of the work. The applications of this study are pointed out at the end of introduction.
Squirmers with swirl: a model for Volvox swimming.
Pedley, T J; Brumley, D R; Goldstein, R E
2016-07-10
Colonies of the green alga Volvox are spheres that swim through the beating of pairs of flagella on their surface somatic cells. The somatic cells themselves are mounted rigidly in a polymeric extracellular matrix, fixing the orientation of the flagella so that they beat approximately in a meridional plane, with axis of symmetry in the swimming direction, but with a roughly [Formula: see text] azimuthal offset which results in the eponymous rotation of the colonies about a body-fixed axis. Experiments on colonies of Volvox carteri held stationary on a micropipette show that the beating pattern takes the form of a symplectic metachronal wave (Brumley et al. Phys. Rev. Lett. , vol. 109, 2012, 268102). Here we extend the Lighthill/Blake axisymmetric, Stokes-flow model of a free-swimming spherical squirmer (Lighthill Commun. Pure Appl. Maths , vol. 5, 1952, pp. 109-118; Blake J. Fluid Mech. , vol. 46, 1971 b , pp. 199-208) to include azimuthal swirl. The measured kinematics of the metachronal wave for 60 different colonies are used to calculate the coefficients in the eigenfunction expansions and hence predict the mean swimming speeds and rotation rates, proportional to the square of the beating amplitude, as functions of colony radius. As a test of the squirmer model, the results are compared with measurements (Drescher et al. Phys. Rev. Lett. , vol. 102, 2009, 168101) of the mean swimming speeds and angular velocities of a different set of 220 colonies, also given as functions of colony radius. The predicted variation with radius is qualitatively correct, but the model underestimates both the mean swimming speed and the mean angular velocity unless the amplitude of the flagellar beat is taken to be larger than previously thought. The reasons for this discrepancy are discussed.
Murasawa, Kengo; Sato, Koki; Hidaka, Takehiko
2011-05-01
A new method for measuring optical-beat frequencies in the terahertz (THz) region using microwave higher harmonics is presented. A microwave signal was applied to the antenna gap of a photoconductive (PC) device emitting a continuous electromagnetic wave at about 1 THz by the photomixing technique. The microwave higher harmonics with THz frequencies are generated in the PC device owing to the nonlinearity of the biased photoconductance, which is briefly described in this article. Thirteen nearly periodic peaks in the photocurrent were observed when the microwave was swept from 16 to 20 GHz at a power of -48 dBm. The nearly periodic peaks are generated by the homodyne detection of the optical beat with the microwave higher harmonics when the frequency of the harmonics coincides with the optical-beat frequency. Each peak frequency and its peak width were determined by fitting a Gaussian function, and the order of microwave harmonics was determined using a coarse (i.e., lower resolution) measurement of the optical-beat frequency. By applying the Kalman algorithm to the peak frequencies of the higher harmonics and their standard deviations, the optical-beat frequency near 1 THz was estimated to be 1029.81 GHz with the standard deviation of 0.82 GHz. The proposed method is applicable to a conventional THz-wave generator with a photomixer.
How molecular motors shape the flagellar beat
Riedel-Kruse, Ingmar H.; Hilfinger, Andreas; Howard, Jonathon; Jülicher, Frank
2007-01-01
Cilia and eukaryotic flagella are slender cellular appendages whose regular beating propels cells and microorganisms through aqueous media. The beat is an oscillating pattern of propagating bends generated by dynein motor proteins. A key open question is how the activity of the motors is coordinated in space and time. To elucidate the nature of this coordination we inferred the mechanical properties of the motors by analyzing the shape of beating sperm: Steadily beating bull sperm were imaged and their shapes were measured with high precision using a Fourier averaging technique. Comparing our experimental data with wave forms calculated for different scenarios of motor coordination we found that only the scenario of interdoublet sliding regulating motor activity gives rise to satisfactory fits. We propose that the microscopic origin of such “sliding control” is the load dependent detachment rate of motors. Agreement between observed and calculated wave forms was obtained only if significant sliding between microtubules occurred at the base. This suggests a novel mechanism by which changes in basal compliance could reverse the direction of beat propagation. We conclude that the flagellar beat patterns are determined by an interplay of the basal properties of the axoneme and the mechanical feedback of dynein motors. PMID:19404446
Hanya, Shizuo
2013-01-01
Lack of high-fidelity simultaneous measurements of pressure and flow velocity in the aorta has impeded the direct validation of the water-hammer formula for estimating regional aortic pulse wave velocity (AO-PWV1) and has restricted the study of the change of beat-to-beat AO-PWV1 under varying physiological conditions in man. Aortic pulse wave velocity was derived using two methods in 15 normotensive subjects: 1) the conventional two-point (foot-to-foot) method (AO-PWV2) and 2) a one-point method (AO-PWV1) in which the pressure velocity-loop (PV-loop) was analyzed based on the water hammer formula using simultaneous measurements of flow velocity (Vm) and pressure (Pm) at the same site in the proximal aorta using a multisensor catheter. AO-PWV1 was calculated from the slope of the linear regression line between Pm and Vm where wave reflection (Pb) was at a minimum in early systole in the PV-loop using the water hammer formula, PWV1 = (Pm/Vm)/ρ, where ρ is the blood density. AO-PWV2 was calculated using the conventional two-point measurement method as the distance/traveling time of the wave between 2 sites for measuring P in the proximal aorta. Beat-to-beat alterations of AO-PWV1 in relationship to aortic pressure and linearity of the initial part of the PV-loop during a Valsalva maneuver were also assessed in one subject. The initial part of the loop became steeper in association with the beat-to-beat increase in diastolic pressure in phase 4 during the Valsalva maneuver. The linearity of the initial part of the PV-loop was maintained consistently during the maneuver. Flow velocity vs. pressure in the proximal aorta was highly linear during early systole, with Pearson's coefficients ranging from 0.9954 to 0.9998. The average values of AO-PWV1 and AO-PWV2 were 6.3 ± 1.2 and 6.7 ± 1.3 m/s, respectively. The regression line of AO-PWV1 on AO-PWV2 was y = 0.95x + 0.68 (r = 0.93, p <0.001). This study concluded that the water-hammer formula (one-point method) provides a reliable and conventional estimate of beat-to-beat aortic regional pulse wave velocity consistently regardless of the changes in physiological states in human clinically. (English Translation of J Jpn Coll Angiol 2011; 51: 215-221).
2013-01-01
Background: Lack of high-fidelity simultaneous measurements of pressure and flow velocity in the aorta has impeded the direct validation of the water-hammer formula for estimating regional aortic pulse wave velocity (AO-PWV1) and has restricted the study of the change of beat-to-beat AO-PWV1 under varying physiological conditions in man. Methods: Aortic pulse wave velocity was derived using two methods in 15 normotensive subjects: 1) the conventional two-point (foot-to-foot) method (AO-PWV2) and 2) a one-point method (AO-PWV1) in which the pressure velocity-loop (PV-loop) was analyzed based on the water hammer formula using simultaneous measurements of flow velocity (Vm) and pressure (Pm) at the same site in the proximal aorta using a multisensor catheter. AO-PWV1 was calculated from the slope of the linear regression line between Pm and Vm where wave reflection (Pb) was at a minimum in early systole in the PV-loop using the water hammer formula, PWV1 = (Pm/Vm)/ρ, where ρ is the blood density. AO-PWV2 was calculated using the conventional two-point measurement method as the distance/traveling time of the wave between 2 sites for measuring P in the proximal aorta. Beat-to-beat alterations of AO-PWV1 in relationship to aortic pressure and linearity of the initial part of the PV-loop during a Valsalva maneuver were also assessed in one subject. Results: The initial part of the loop became steeper in association with the beat-to-beat increase in diastolic pressure in phase 4 during the Valsalva maneuver. The linearity of the initial part of the PV-loop was maintained consistently during the maneuver. Flow velocity vs. pressure in the proximal aorta was highly linear during early systole, with Pearson’s coefficients ranging from 0.9954 to 0.9998. The average values of AO-PWV1 and AO-PWV2 were 6.3 ± 1.2 and 6.7 ± 1.3 m/s, respectively. The regression line of AO-PWV1 on AO-PWV2 was y = 0.95x + 0.68 (r = 0.93, p <0.001). Conclusion: This study concluded that the water-hammer formula (one-point method) provides a reliable and conventional estimate of beat-to-beat aortic regional pulse wave velocity consistently regardless of the changes in physiological states in human clinically. (*English Translation of J Jpn Coll Angiol 2011; 51: 215-221) PMID:23825494
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yadav, Pinki; Gupta, D. N., E-mail: dngupta@physics.du.ac.in; Avinash, K.
2016-01-15
Stimulated Brillouin instability of a beat-wave of two lasers in plasmas with multiple-ion-species (negative-ions) was studied. The inclusion of negative-ions affects the growth of ion-acoustic wave in Brillouin scattering. Thus, the growth rate of instability is suppressed significantly by the density of negative-ions. To obey the phase-matching condition, the growth rate of the instability attains a maxima for an appropriate scattering angle (angle between the pump and scattered sideband waves). This study would be technologically important to have diagnostics in low-temperature plasmas.
Scaling dependence and synchronization of forced mercury beating heart systems
NASA Astrophysics Data System (ADS)
Biswas, Animesh; Das, Dibyendu; Parmananda, P.
2017-04-01
We perform experiments on a nonautonomous Mercury beating heart system, which is forced to pulsate using an external square wave potential. At suitable frequencies and volumes, the drop exhibits pulsation with polygonal shapes having n corners. We find the scaling dependence of the forcing frequency νn on the volume V of the drop and establish the relationship νn∝n/√{V } . It is shown that the geometrical shape of substrate is important for obtaining closer match to these scaling relationships. Furthermore, we study synchronization of two nonidentical drops driven by the same frequency and establish that synchrony happens when the relationship n2/n1=√{V2/V1 } is satisfied.
Ion acoustic wave assisted laser beat wave terahertz generation in a plasma channel
NASA Astrophysics Data System (ADS)
Tyagi, Yachna; Tripathi, Deepak; Walia, Keshav; Garg, Deepak
2018-04-01
Resonant excitation of terahertz (THz) radiation by non-linear mixing of two lasers in the presence of an electrostatic wave is investigated. The electrostatic wave assists in k matching and contributes to non-linear coupling. In this plasma channel, the electron plasma frequency becomes minimum on the axis. The beat frequency ponderomotive force imparts an oscillating velocity to the electrons. In the presence of an ion-acoustic wave, density perturbation due to the ion-acoustic wave couples with the oscillating velocity of the electrons and give rise to non-linear current that gives rise to an ion-acoustic wave frequency assisted THz radiation field. The normalized field amplitude of ion acoustic wave assisted THz varies inversely for ω/ωp . The field amplitude of ion acoustic wave assisted THz decreases as ω/ωp increases.
The physics of musical scales: Theory and experiment
NASA Astrophysics Data System (ADS)
Durfee, Dallin S.; Colton, John S.
2015-10-01
The theory of musical scales involves mathematical ratios, harmonic resonators, beats, and human perception and provides an interesting application of the physics of waves and sound. We first review the history and physics of musical scales, with an emphasis on four historically important scales: twelve-tone equal temperament, Pythagorean, quarter-comma meantone, and Ptolemaic just intonation. We then present an easy way for students and teachers to directly experience the qualities of different scales using MIDI synthesis.
Theory for low-frequency modulated Langmuir wave packets
NASA Technical Reports Server (NTRS)
Cairns, Iver H.; Robinson, P. A.
1992-01-01
Langmuir wave packets with low frequency modulations (or beats) observed in the Jovian foreshock are argued to be direct evidence for the Langmuir wave decay L yields L-prime + S. In this decay, 'pump' Langmuir waves L, driven by an electron beam, produce backscattered product Langmuir waves L-prime and ion sound waves S. The L and L-prime waves beat at the frequency and wavevector of the S waves, thereby modulating the wave packets. Beam speeds calculated using the modulated Jovian wave packets (1) are reasonable, at 4-10 times the electron thermal speed, (2) are consistent with theoretical limits on the decay process, and (3) decrease with increasing foreshock depth, as expected theoretically. These results strongly support the theory. The modulation depth of some wave packets suggests saturation by the decay L yields L-prime + S. Applications to modulated Langmuir packets in the Venusian and terrestrial foreshocks and in a type III radio source are proposed.
Broux, B; De Clercq, D; Decloedt, A; Van Der Vekens, N; Verheyen, T; Ven, S; Pardon, B; van Loon, G
2016-07-01
The electrocardiographic differentiation between atrial (APDs) and ventricular (VPDs) premature depolarizations is important. P wave prematurity and normal QRS and T wave morphology generally are used as discriminating criteria for APDs. The aim of this study was to determine whether P, Q, R, S, and T wave amplitude, PQ interval, QRS and P wave duration and P and T wave morphology differ between APDs and sinus beats. To determine the relationship between the RR coupling interval and the change in S wave amplitude between sinus beats and APDs. Case-control study. From a modified base-apex configuration of 30 horses with APDs at rest, sinus beat and APD associated preceding RR interval, P, PQ and QRS duration and P, R, S, and T wave amplitudes were measured. Linear mixed models and logistic regression were used to determine the effect of APDs on the ECG variables studied. In comparison to sinus beats, APDs were associated with a significant (P < .001) change in P amplitude (-0.03 ± 0.01 mV) and increase in S (0.20 ± 0.02 mV) and T (0.08 ± 0.03 mV) amplitude. PQ (-20.3 ± 5.2 ms) and RR (-519 ± 14 ms) interval and P duration (-21.1 ± 3.0 ms) decreased (P < .001). APDs were significantly associated with a singular positive P wave (OR: 11.0, P < .001) and were more likely to have a monophasic positive T wave (OR: 9.2, P < .001). A smaller RR coupling interval was associated with an increased relative difference in S amplitude (P < .01). Atrial premature depolarizations may lead to changes in QRS and T wave morphology. Knowledge of these changes is important to avoid interpreting certain APDs as VPDs. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Saturation of multi-laser beams laser-plasma instabilities from stochastic ion heating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michel, P.; Williams, E. A.; Divol, L.
2013-05-15
Cross-beam energy transfer (CBET) has been used as a tool on the National Ignition Facility (NIF) since the first energetics experiments in 2009 to control the energy deposition in ignition hohlraums and tune the implosion symmetry. As large amounts of power are transferred between laser beams at the entrance holes of NIF hohlraums, the presence of many overlapping beat waves can lead to stochastic ion heating in the regions where laser beams overlap [P. Michel et al., Phys. Rev. Lett. 109, 195004 (2012)]. This increases the ion acoustic velocity and modifies the ion acoustic waves’ dispersion relation, thus reducing themore » plasma response to the beat waves and the efficiency of CBET. This pushes the plasma oscillations driven by CBET in a regime where the phase velocities are much smaller than both the electron and ion thermal velocities. CBET gains are derived for this new regime and generalized to the case of multi ion species plasmas.« less
Zones, spots, and planetary-scale waves beating in brown dwarf atmospheres.
Apai, D; Karalidi, T; Marley, M S; Yang, H; Flateau, D; Metchev, S; Cowan, N B; Buenzli, E; Burgasser, A J; Radigan, J; Artigau, E; Lowrance, P
2017-08-18
Brown dwarfs are massive analogs of extrasolar giant planets and may host types of atmospheric circulation not seen in the solar system. We analyzed a long-term Spitzer Space Telescope infrared monitoring campaign of brown dwarfs to constrain cloud cover variations over a total of 192 rotations. The infrared brightness evolution is dominated by beat patterns caused by planetary-scale wave pairs and by a small number of bright spots. The beating waves have similar amplitudes but slightly different apparent periods because of differing velocities or directions. The power spectrum of intermediate-temperature brown dwarfs resembles that of Neptune, indicating the presence of zonal temperature and wind speed variations. Our findings explain three previously puzzling behaviors seen in brown dwarf brightness variations. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
NASA Astrophysics Data System (ADS)
Dorfman, S.; Carter, T.; Pribyl, P.; Tripathi, S. K. P.; van Compernolle, B.; Vincena, S.; Sydora, R.
2013-10-01
Alfvén waves, a fundamental mode of magnetized plasmas, are ubiquitous in lab and space. While the linear behavior of these waves has been extensively studied, non-linear effects are important in many real systems, including the solar wind and solar corona. In particular, a parametric decay process in which a large amplitude Alfvén wave decays into an ion acoustic wave and backward propagating Alfvén wave may play an important role in coronal heating and/or in establishing the spectrum of solar wind turbulence. Recent counter-propagating Alfvén wave experiments have recorded the first laboratory observation of the Alfvén-acoustic mode coupling at the heart of this parametric decay instability. The resonance in the observed beat process has several features consistent with ponderomotive coupling to an ion acoustic mode, including the measured dispersion relation and spatial profile. Strong damping observed after the pump Alfvén waves are turned off is under investigation. New experiments and simulations also aim to identify decay instabilities from a single large-amplitude Alfvén wave. Supported by DOE and NSF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aburjania, G. D.; Machabeli, G. Z.; Kharshiladze, O. A.
2006-07-15
The modulational instability in a plasma in a strong constant external magnetic field is considered. The plasmon condensate is modulated not by conventional low-frequency ion sound but by the beatings of two high-frequency transverse electromagnetic waves propagating along the magnetic field. The instability reduces the spatial scales of Langmuir turbulence along the external magnetic field and generates electromagnetic fields. It is shown that, for a pump wave with a sufficiently large amplitude, the effect described in the present paper can be a dominant nonlinear process.
Modulational instability of beat waves in a transversely magnetized plasma: Ion effects
NASA Astrophysics Data System (ADS)
Ferdous, T.; Amin, M. R.; Salimullah, M.
1996-05-01
The effect of ion dynamics on the modulational instability of the electrostatic beat wave at the difference frequency of two incident laser beams in a hot, collisionless, and transversely magnetized plasma has been studied theoretically. The full Vlasov equation in terms of gyrokinetic variables is employed to obtain the nonlinear response of ions and electrons. It is found that the growth rate of modulational instability is about two orders higher when ion motions are included.
Destructive tsunami-like wave generated by surf beat over a coral reef during Typhoon Haiyan.
Roeber, Volker; Bricker, Jeremy D
2015-08-06
Storm surges cause coastal inundation due to setup of the water surface resulting from atmospheric pressure, surface winds and breaking waves. Here we show that during Typhoon Haiyan, the setup generated by breaking waves near the fringing-reef-protected town of Hernani, the Philippines, oscillated with the incidence of large and small wave groups, and steepened into a tsunami-like wave that caused extensive damage and casualties. Though fringing reefs usually protect coastal communities from moderate storms, they can exacerbate flooding during strong events with energetic waves. Typical for reef-type bathymetries, a very short wave-breaking zone over the steep reef face facilitates the freeing of infragravity-period fluctuations (surf beat) with little energy loss. Since coastal flood planning relies on phase-averaged wave modelling, infragravity surges are not being accounted for. This highlights the necessity for a policy change and the adoption of phase-resolving wave models for hazard assessment in regions with fringing reefs.
Destructive tsunami-like wave generated by surf beat over a coral reef during Typhoon Haiyan
Roeber, Volker; Bricker, Jeremy D.
2015-01-01
Storm surges cause coastal inundation due to setup of the water surface resulting from atmospheric pressure, surface winds and breaking waves. Here we show that during Typhoon Haiyan, the setup generated by breaking waves near the fringing-reef-protected town of Hernani, the Philippines, oscillated with the incidence of large and small wave groups, and steepened into a tsunami-like wave that caused extensive damage and casualties. Though fringing reefs usually protect coastal communities from moderate storms, they can exacerbate flooding during strong events with energetic waves. Typical for reef-type bathymetries, a very short wave-breaking zone over the steep reef face facilitates the freeing of infragravity-period fluctuations (surf beat) with little energy loss. Since coastal flood planning relies on phase-averaged wave modelling, infragravity surges are not being accounted for. This highlights the necessity for a policy change and the adoption of phase-resolving wave models for hazard assessment in regions with fringing reefs. PMID:26245839
Model for the respiratory modulation of the heart beat-to-beat time interval series
NASA Astrophysics Data System (ADS)
Capurro, Alberto; Diambra, Luis; Malta, C. P.
2005-09-01
In this study we present a model for the respiratory modulation of the heart beat-to-beat interval series. The model consists of a set of differential equations used to simulate the membrane potential of a single rabbit sinoatrial node cell, excited with a periodic input signal with added correlated noise. This signal, which simulates the input from the autonomous nervous system to the sinoatrial node, was included in the pacemaker equations as a modulation of the iNaK current pump and the potassium current iK. We focus at modeling the heart beat-to-beat time interval series from normal subjects during meditation of the Kundalini Yoga and Chi techniques. The analysis of the experimental data indicates that while the embedding of pre-meditation and control cases have a roughly circular shape, it acquires a polygonal shape during meditation, triangular for the Kundalini Yoga data and quadrangular in the case of Chi data. The model was used to assess the waveshape of the respiratory signals needed to reproduce the trajectory of the experimental data in the phase space. The embedding of the Chi data could be reproduced using a periodic signal obtained by smoothing a square wave. In the case of Kundalini Yoga data, the embedding was reproduced with a periodic signal obtained by smoothing a triangular wave having a rising branch of longer duration than the decreasing branch. Our study provides an estimation of the respiratory signal using only the heart beat-to-beat time interval series.
Aizawa, Yoshifusa; Sato, Masahito; Kitazawa, Hitoshi; Aizawa, Yoshiyasu; Takatsuki, Seiji; Oda, Eiji; Okabe, Masaaki; Fukuda, Keiichi
2015-02-01
J waves can be observed in individuals of the general population, but electrocardiographic characteristics are poorly understood. The purpose of this study was to examine the J-wave dynamicity in a general patient population. The responses of J waves (>0.1 mV above the isoelectric line in 2 contiguous leads) to varying RR intervals were analyzed. Patients with aborted sudden cardiac death, documented ventricular fibrillation, or a family history of sudden cardiac death were excluded. The J-wave amplitude was measured at baseline, in beats with short RR intervals in conducted atrial premature beats (APBs) or atrial stimulation during the electrophysiology study, and in the beats next to APBs with prolonged RR intervals. Mainly notched J waves were identified in 94 of 701 (24.5%) general patients (13.4%), and APBs were present in 23 of 94 (24.5%) patients. The mean baseline amplitude of J waves was 0.20 ± 0.06 mV at the baseline RR interval of 853 ± 152 ms, 0.25 ± 0.11 mV at the RR interval in the conducted APB of 545 ± 133 ms (P = .0018), and 0.19 ± 0.08 mV at the RR interval of 1146 ± 314 ms (P = .3102). The clinical characteristics were not different between patients with and without tachycardia-dependent augmentation of J waves. Augmentation of J waves was confirmed by the electrophysiology study: 0.28 ± 0.12 mV vs 0.42 ± 0.11 mV at baseline and in the beats of atrial stimulation, respectively (P = .0001). However, no bradycardia-dependent augmentation (>0.05 mV) was observed. Such tachycardia-dependent augmentation can represent depolarization abnormality rather than repolarization abnormality. J waves in a general patient population were augmented at shorter RR intervals, but not at prolonged RR intervals. Mechanistically, conduction delay is most likely responsible for this. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Wang, Huai-Yung; Chi, Yu-Chieh; Lin, Gong-Ru
2016-08-08
A novel millimeter-wave radio over fiber (MMW-RoF) link at carrier frequency of 35-GHz is proposed with the use of remotely beating MMW generation from reference master and injected slave colorless laser diode (LD) carriers at orthogonally polarized dual-wavelength injection-locking. The slave colorless LD supports lasing one of the dual-wavelength master modes with orthogonal polarizations, which facilitates the single-mode direct modulation of the quadrature amplitude modulation (QAM) orthogonal frequency division multiplexing (OFDM) data. Such an injected single-carrier encoding and coupled dual-carrier transmission with orthogonal polarization effectively suppresses the cross-heterodyne mode-beating intensity noise, the nonlinear modulation (NLM) and four-wave mixing (FWM) sidemodes during injection locking and fiber transmission. In 25-km single-mode fiber (SMF) based wireline system, the dual-carrier under single-mode encoding provides baseband 24-Gbit/s 64-QAM OFDM transmission with an error vector magnitude (EVM) of 8.8%, a bit error rate (BER) of 3.7 × 10-3, a power penalty of <1.5 dB. After remotely self-beating for wireless transmission, the beat MMW carrier at 35 GHz can deliver the passband 16-QAM OFDM at 4 Gbit/s to show corresponding EVM and BER of 15.5% and 1.4 × 10-3, respectively, after 25-km SMF and 1.6-m free-space transmission.
A microprocessor-based cardiotachometer
NASA Technical Reports Server (NTRS)
Donaldson, J. A.; Crosier, W. G.
1979-01-01
The development of a highly accurate and reliable cardiotachometer for measuring the heart rate of test subjects is discussed. It measures heart rate over the range of 30 to 250 beats/minute and gives instantaneous (beat to beat) updates on the system output so that occasional noise artifacts or ectopic beats could be more easily identified except that occasional missed beats caused by switching ECG leads should not cause a change in the output. The cardiotachometer uses an improved analog filter and R-wave detector and an Intel 8080A microprocessor to handle all of the logic and arithmetic necessary. By using the microprocessor, future hardware modifications could easily be made if functional changes were needed.
NASA Astrophysics Data System (ADS)
Stefan, V. Alexander
2011-03-01
I propose a novel mechanism for the brain cancer tissue treatment: nonlinear interaction of ultrashort pulses of beat-photon, (ω1 -- ω2) , or double-photon, (ω1 +ω2) , beams with the cancer tissue. The multiphoton scattering is described via photon diffusion equation. The open-scull cerebral tissue can be irradiated with the beat-modulated photon pulses with the laser irradiances in the range of a few mW/cm2 , and repetition rate of a few 100s Hz generated in the beat-wave driven free electron laser. V. Stefan, B. I. Cohen, and C. Joshi, Nonlinear Mixing of Electromagnetic Waves in PlasmasScience 27 January 1989: V. Alexander Stefan, Genomic Medical Physics: A New Physics in the Making, (S-U-Press, 2008).} This highly accurate cancer tissue ablation removal may prove to be an efficient method for the treatment of brain cancer. Work supported in part by Nikola Tesla Laboratories (Stefan University), La Jolla, CA.
Calcium (Ca2+) waves data calibration and analysis using image processing techniques
2013-01-01
Background Calcium (Ca2+) propagates within tissues serving as an important information carrier. In particular, cilia beat frequency in oviduct cells is partially regulated by Ca2+ changes. Thus, measuring the calcium density and characterizing the traveling wave plays a key role in understanding biological phenomena. However, current methods to measure propagation velocities and other wave characteristics involve several manual or time-consuming procedures. This limits the amount of information that can be extracted, and the statistical quality of the analysis. Results Our work provides a framework based on image processing procedures that enables a fast, automatic and robust characterization of data from two-filter fluorescence Ca2+ experiments. We calculate the mean velocity of the wave-front, and use theoretical models to extract meaningful parameters like wave amplitude, decay rate and time of excitation. Conclusions Measurements done by different operators showed a high degree of reproducibility. This framework is also extended to a single filter fluorescence experiments, allowing higher sampling rates, and thus an increased accuracy in velocity measurements. PMID:23679062
``Smart'' baroreception along the aortic arch, with reference to essential hypertension
NASA Astrophysics Data System (ADS)
Kember, G. C.; Zamir, M.; Armour, J. A.
2004-11-01
Beat-to-beat regulation of heart rate is dependent upon sensing of local stretching or local “disortion” by aortic baroreceptors. Distortions of the aortic wall are due mainly to left ventricular output and to reflected waves arising from the arterial tree. Distortions are generally believed to be useful in cardiac control since stretch receptors or aortic baroreceptors embedded in the adventitia of the aortic wall, transduce the distortions to cardiovascular neural reflex pathways responsible for beat-to-beat regulation of heart rate. Aortic neuroanatomy studies have also found a continuous strip of mechanosensory neurites spread along the aortic inner arch. Although their purpose is now unknown, such a combined sensing capacity would allow measurement of the space and time dependence of inner arch wall distortions due, among other things, to traveling waves associated with pulsatile flow in an elastic tube. We call this sensing capability-“smart baroreception.” In this paper we use an arterial tree model to show that the cumulative effects of wave reflections, from many sites far downstream, have a surprisingly pronounced effect on the pressure distribution in the root segment of the tree. By this mechanism global hemodynamics can be focused by wave reflections back to the aortic arch, where they can rapidly impact cardiac control via smart baroreception. Such sensing is likely important to maintain efficient heart function. However, alterations in the arterial tree due to aging and other natural processes can lead in such a system to altered cardiac control and essential hypertension.
Load Response of the Flagellar Beat
NASA Astrophysics Data System (ADS)
Klindt, Gary S.; Ruloff, Christian; Wagner, Christian; Friedrich, Benjamin M.
2016-12-01
Cilia and flagella exhibit regular bending waves that perform mechanical work on the surrounding fluid, to propel cellular swimmers and pump fluids inside organisms. Here, we quantify a force-velocity relationship of the beating flagellum, by exposing flagellated Chlamydomonas cells to controlled microfluidic flows. A simple theory of flagellar limit-cycle oscillations, calibrated by measurements in the absence of flow, reproduces this relationship quantitatively. We derive a link between the energy efficiency of the flagellar beat and its ability to synchronize to oscillatory flows.
Single-photon superradiant beating from a Doppler-broadened ladder-type atomic ensemble
NASA Astrophysics Data System (ADS)
Lee, Yoon-Seok; Lee, Sang Min; Kim, Heonoh; Moon, Han Seb
2017-12-01
We report on heralded-single-photon superradiant beating in the spontaneous four-wave mixing process of Doppler-broadened ladder-type 87Rb atoms. When Doppler-broadened atoms contribute to two-photon coherence, the detection probability amplitudes of the heralded single photons are coherently superposed despite inhomogeneous broadened atomic media. Single-photon superradiant beating is observed, which constitutes evidence for the coherent superposition of two-photon amplitudes from different velocity classes in the Doppler-broadened atomic ensemble. We present a theoretical model in which the single-photon superradiant beating originates from the interference between wavelength-separated two-photon amplitudes via the reabsorption filtering effect.
Measuring and characterizing beat phenomena with a smartphone
NASA Astrophysics Data System (ADS)
Osorio, M.; Pereyra, C. J.; Gau, D. L.; Laguarda, A.
2018-03-01
Nowadays, smartphones are in everyone’s life. Apart from being excellent tools for work and communication, they can also be used to perform several measurements of simple physical magnitudes, serving as a mobile and inexpensive laboratory, ideal for use physics lectures in high schools or universities. In this article, we use a smartphone to analyse the acoustic beat phenomena by using a simple experimental setup, which can complement lessons in the classroom. The beats were created by the superposition of the waves generated by two tuning forks, with their natural frequencies previously characterized using different applications. After the characterization, we recorded the beats and analysed the oscillations in time and frequency.
Myocardial effects of local shock wave therapy in a Langendorff model.
Becker, M; Goetzenich, A; Roehl, A B; Huebel, C; de la Fuente, M; Dietz-Laursonn, K; Radermacher, K; Rossaint, R; Hein, M
2014-01-01
Applying shock waves to the heart has been reported to stimulate the heart and alter cardiac function. We hypothesized that shock waves could be used to diagnose regional viability. We used a Langendorff model to investigate the acute effects of shock waves at different energy levels and times related to systole, cycle duration and myocardial function. We found only a small time window to use shock waves. Myocardial fibrillation or extrasystolic beats will occur if the shock wave is placed more than 15 ms before or 30 ms after the onset of systole. Increased contractility and augmented relaxation were observed after the second beat, and these effects decreased after prolonging the shock wave delay from 15 ms before to 30 ms after the onset of systole. An energy dependency could be found only after short delays (-15 ms). The involved processes might include post-extrasystolic potentiation and simultaneous pacing. In summary, we found that low-energy shock waves can be a useful tool to stimulate the myocardium at a distance and influence function. Copyright © 2013 Elsevier B.V. All rights reserved.
Pflugradt, Maik; Geissdoerfer, Kai; Goernig, Matthias; Orglmeister, Reinhold
2017-01-14
Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG). Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations' vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway.
Rodriguez-Fernandez, Rodrigo; Infante, Oscar; Perez-Grovas, Héctor; Hernandez, Erika; Ruiz-Palacios, Patricia; Franco, Martha; Lerma, Claudia
2012-06-01
This study evaluated the usefulness of the three-dimensional representation of electrocardiogram traces (3DECG) to reveal acute and gradual changes during a full session of hemodiafiltration (HDF) in end-stage renal disease (ESRD) patients. Fifteen ESRD patients were included (six men, nine women, age 46 ± 19 years old). Serum electrolytes, blood pressure, heart rate, and blood urea nitrogen (BUN) were measured before and after HDF. Continuous electrocardiograms (ECGs) obtained by Holter monitoring during HDF were used to produce the 3DECG. Several major disturbances were identified by 3DECG images: increase in QRS amplitude (47%), decrease in T-wave amplitude (33%), increase in heart rate (33%), and occurrence of arrhythmia (53%). Different arrhythmia types were often concurrent and included isolated supraventricular premature beats (N = 5), atrial fibrillation or atrial bigeminy (N = 2), and isolated premature ventricular beats (N = 6). Patients with decrease in T-wave amplitude had higher potassium and BUN (both before HDF and total removal) than those without decrease in T-wave amplitude (P < 0.05). Concurrent acute and gradual ECG changes during HDF are identified by the 3DECG, which could be useful as a preventive and prognostic method. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Kim, Namje; Han, Sang-Pil; Ko, Hyunsung; Leem, Young Ahn; Ryu, Han-Cheol; Lee, Chul Wook; Lee, Donghun; Jeon, Min Yong; Noh, Sam Kyu; Park, Kyung Hyun
2011-08-01
We demonstrate a tunable continuous-wave (CW) terahertz (THz) homodyne system with a novel detuned dual-mode laser diode (DML) and low-temperature-grown (LTG) InGaAs photomixers. The optical beat source with the detuned DML showed a beat frequency tuning range of 0.26 to over 1.07 THz. Log-spiral antenna integrated LTG InGaAs photomixers are used as THz wave generators and detectors. The CW THz radiation frequency was continuously tuned to over 1 THz. Our results clearly show the feasibility of a compact and fast scanning CW THz spectrometer consisting of a fiber-coupled detuned DML and photomixers operating in the 1.55-μm range.
Paramecium swimming and ciliary beating patterns: a study on four RNA interference mutations.
Funfak, Anette; Fisch, Cathy; Abdel Motaal, Hatem T; Diener, Julien; Combettes, Laurent; Baroud, Charles N; Dupuis-Williams, Pascale
2015-01-01
Paramecium cells swim and feed by beating their thousands of cilia in coordinated patterns. The organization of these patterns and its relationship with cell motility has been the subject of a large body of work, particularly as a model for ciliary beating in human organs where similar organization is seen. However the rapid motion of the cells makes quantitative measurements very challenging. Here we provide detailed measurements of the swimming of Paramecium cells from high-speed video at high magnification, as they move in microfluidic channels. An image analysis protocol allows us to decouple the cell movement from the motion of the cilia, thus allowing us to measure the ciliary beat frequency (CBF) and the spatio-temporal organization into metachronal waves along the cell periphery. Two distinct values of the CBF appear at different regions of the cell: most of the cilia beat in the range of 15 to 45 Hz, while the cilia in the peristomal region beat at almost double the frequency. The body and peristomal CBF display a nearly linear relation with the swimming velocity. Moreover the measurements do not display a measurable correlation between the swimming velocity and the metachronal wave velocity on the cell periphery. These measurements are repeated for four RNAi silenced mutants, where proteins specific to the cilia or to their connection to the cell base are depleted. We find that the mutants whose ciliary structure is affected display similar swimming to the control cells albeit with a reduced efficiency, while the mutations that affect the cilia's anchoring to the cell lead to strongly reduced ability to swim. This reduction in motility can be related to a loss of coordination between the ciliary beating in different parts of the cell.
NASA Astrophysics Data System (ADS)
Saprykina, Yana; Divinskii, Boris
2013-04-01
An infragravity waves are long waves with periods of 20 - 300 s. Most essential influence of infragarvity waves on dynamic processes is in a coastal zone, where its energy can exceed the energy of wind waves. From practical point of view, the infragravity waves are important, firstly, due to their influence on sand transport processes in a coastal zone. For example, interacting with group structure of wind waves the infragravity waves can define position of underwater bars on sandy coast. Secondly, they are responsible on formation of long waves in harbors. Main source of infragravity waves is wave group structure defined by sub-nonlinear interactions of wind waves (Longuet-Higgins, Stewart, 1962). These infragravity waves are bound with groups of wind waves and propagate with wave group velocity. Another type of infragravity waves are formed in a surf zone as a result of migration a wave breaking point (Symonds, et al., 1982). What from described above mechanisms of formation of infragravity waves prevails, till now it is unknown. It is also unknown how energy of infragravity waves depends on energy of input wind waves and how it changes during nonlinear wave transformation in coastal zone. In our work on the basis of the analysis of data of field experiment and numerical simulation a contribution of infragravity waves in total wave energy in depending on integral characteristics of an irregular wave field in the conditions of a real bathymetry was investigated. For analysis the data of field experiment "Shkorpilovtsy-2007" (Black sea) and data of numerical modeling of Boussinesq type equation with extended dispersion characteristics (Madsen et al., 1997) were used. It was revealed that infragravity waves in a coastal zone are defined mainly by local group structure of waves, which permanently changes due to nonlinearity, shoaling and breaking processes. Free infragravity waves appearing after wave breaking exist together with bound infragravity waves. There are no clear total dependences of energy of infrragravity waves from energy of wind waves and mean period of infragravity waves from mean period of wind waves. But significant wave height of infragravity waves depends on relative water depth (wave height of wind waves divided on water depth). There are different types of this dependence for breaking and non-breaking waves. The influence of peak period, significant wave height and directional spreading of initial wave spectrum on these dependences are discussed. The peculiarities of spectra of infragravity waves for non-breaking, breaking and multibreaking wind waves are shown. This work is supported by the RFBR, project 12-05-00965. References: Longuet-Higgins, M. S., R. W. Stewart, 1962. Radiation stress and mass transport in gravity waves, with an application to surf beats. J. Fluid Mech., 13, pp. 481-504. Symonds G., D.A. Huntley, A.J. Bowen, 1982. Two dimensional surf beat: long wave generation by a time-varying breakpoint. J. of Geoph. Res., 87(C), pp.492-498. Madsen P.A., Sorensen O.R., Shaffer H.A. 1997. Surf zone dynamics simulated by a Boussinesq type model. Coastal Engineering, 32, p. 255-287.
Heterodyne laser instantaneous frequency measurement system
Wyeth, Richard W.; Johnson, Michael A.; Globig, Michael A.
1989-01-01
A heterodyne laser instantaneous frequency measurement system is disclosed. The system utilizes heterodyning of a pulsed laser beam with a continuous wave laser beam to form a beat signal. The beat signal is processed by a controller or computer which determines both the average frequency of the laser pulse and any changes or chirp of th frequency during the pulse.
Beat note stabilization of a 10-60 GHz dual-polarization microlaser through optical down conversion.
Rolland, A; Brunel, M; Loas, G; Frein, L; Vallet, M; Alouini, M
2011-02-28
Down-conversion of a high-frequency beat note to an intermediate frequency is realized by a Mach-Zehnder intensity modulator. Optically-carried microwave signals in the 10-60 GHz range are synthesized by using a two-frequency solid-state microchip laser as a voltage-controlled oscillator inside a digital phase-locked loop. We report an in-loop relative frequency stability better than 2.5×10⁻¹¹. The principle is applicable to beat notes in the millimeter-wave range.
Nabeel, P M; Jayaraj, J; Mohanasankar, S
2017-11-30
A novel photoplethysmograph probe employing dual photodiodes excited using a single infrared light source was developed for local pulse wave velocity (PWV) measurement. The potential use of the proposed system in cuffless blood pressure (BP) techniques was demonstrated. Initial validation measurements were performed on a phantom using a reference method. Further, an in vivo study was carried out in 35 volunteers (age = 28 ± 4.5 years). The carotid local PWV, carotid to finger pulse transit time (PTT R ) and pulse arrival time at the carotid artery (PAT C ) were simultaneously measured. Beat-by-beat variation of the local PWV due to BP changes was studied during post-exercise relaxation. The cuffless BP estimation accuracy of local PWV, PAT C , and PTT R was investigated based on inter- and intra-subject models with best-case calibration. The accuracy of the proposed system, hardware inter-channel delay (<0.1 ms), repeatability (beat-to-beat variation = 4.15%-11.38%) and reproducibility of measurement (r = 0.96) were examined. For the phantom experiment, the measured PWV values did not differ by more than 0.74 m s -1 compared to the reference PWV. Better correlation was observed between brachial BP parameters versus local PWV (r = 0.74-0.78) compared to PTT R (|r| = 0.62-0.67) and PAT C (|r| = 0.52-0.68). Cuffless BP estimation using local PWV was better than PTT R and PAT C with population-specific models. More accurate estimates of arterial BP levels were achieved using local PWV via subject-specific models (root-mean-square error ⩽2.61 mmHg). A reliable system for cuffless BP measurement and local estimation of arterial wall properties.
Dichromatic Langmuir waves in degenerate quantum plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dubinov, A. E., E-mail: dubinov-ae@yandex.ru; Kitayev, I. N.
2015-06-15
Langmuir waves in fully degenerate quantum plasma are considered. It is shown that, in the linear approximation, Langmuir waves are always dichromatic. The low-frequency component of the waves corresponds to classical Langmuir waves, while the high-frequency component, to free-electron quantum oscillations. The nonlinear problem on the profile of dichromatic Langmuir waves is solved. Solutions in the form of a superposition of waves and in the form of beatings of its components are obtained.
Influences on water-hammer wave shape: an experimental study
NASA Astrophysics Data System (ADS)
Traudt, T.; Bombardieri, C.; Manfletti, C.
2016-09-01
Water-hammer phenomena are of strong interest in a number of different industrial fields, amongst which the space industry. Here the priming of feedlines during start-up of an engine as well as the rapid closing of valves upon shutdown may lead to pressure peaks symptomatic of a water-hammer wave. Test benches used to conduct tests on future as well as current engines are also sensitive to water-hammer waves traveling along their feedlines. To enhance the understanding of water-hammer, we investigated different configurations and their influence on the wave shape in the frequency domain. The configurations feature a coiled pipe setup with a support structure and without a support structure. Two other phenomena will be presented. We found a beat phenomenon which is likely to be the so called Poisson-coupling beat. Finally we will show that the second water-hammer peak can reach pressures a lot higher than the first peak by additive interference of the primary and secondary water-hammer wave.
Oscillating two-stream instability of beat waves in a hot magnetized plasma
NASA Astrophysics Data System (ADS)
Ferdous, T.; Amin, M. R.; Salimullah, M.
1997-02-01
It is shown that an electrostatic electron plasma beat wave is efficiently unstable for a low-frequency and short-wave-length purely growing perturbation (ω, k), i.e. an oscillating two-stream instability in a transversely magnetized hot plasma. The nonlinear response of electrons and ions with strong finite Larmor radius effects has been obtained by solving the Vlasov equation expressed in the guiding-center coordinates. The effect of ion dynamics has been found to play a vital role around ω ∼ ωci, where ωci is the ion-cyclotron frequency. For typical plasma parameters, it is found that the maximum growth rate of the instability is about two orders higher when ion motion is taken into account in addition to the electron dynamics.
Nonlinear Interaction of the Beat-Photon Beams with the Brain Neurocenters: Laser Neurophysics
NASA Astrophysics Data System (ADS)
Stefan, V. Alexander
2010-03-01
I propose a novel mechanism for laser-brain interaction: Nonlinear interaction of ultrashort pulses of beat-photon, (φ1-- φ2), or double-photon, (φ1+φ2), footnotetextMaria Goeppert-Mayer, "Uber Elementarakte mit zwei Quantenspr"ungen, Ann Phys 9, 273, 95. (1931). beams with the corrupted brain neurocenters, causing a particular neurological disease. The open-scull cerebral tissue can be irradiated with the beat-photon pulses in the range of several 100s fs, with the laser irradiances in the range of a few mW/cm^2, repetition rate of a few 100s Hz, and in the frequency range of 700-1300nm generated in the beat-wave driven free electron laser.footnotetextV. Alexander Stefan, The Interaction of Photon Beams with the DNA Molecules: Genomic Medical Physics. American Physical Society, 2009 APS March Meeting, March 16-20, 2009, abstract #K1.276; V. Stefan, B. I. Cohen, and C. Joshi, Nonlinear Mixing of Electromagnetic Waves in Plasmas Science 27 January 1989:Vol. 243. no. 4890, pp. 494 -- 500 (January 1989). This method may prove to be an effective mechanism in the treatment of neurological diseases: Parkinson's, Lou Gehrig's, and others.
Yang, L G; Sung, J Y; Chow, C W; Yeh, C H; Cheng, K T; Shi, J W; Pan, C L
2014-10-20
We demonstrate experimentally Manchester (MC) coding based W-band (75 - 110 GHz) radio-over-fiber (ROF) system to reduce the low-frequency-components (LFCs) signal distortion generated by two independent low-cost lasers using spectral shaping. Hence, a low-cost and higher performance W-band ROF system is achieved. In this system, direct-beating of two independent low-cost CW lasers without frequency tracking circuit (FTC) is used to generate the millimeter-wave. Approaches, such as delayed self-heterodyne interferometer and heterodyne beating are performed to characterize the optical-beating-interference sub-terahertz signal (OBIS). Furthermore, W-band ROF systems using MC coding and NRZ-OOK are compared and discussed.
Proofs for the Wave Theory of Plants
NASA Astrophysics Data System (ADS)
Wagner, Orvin E.
1997-03-01
Oscillatory behavior in plants. (2)Standing waves observed coming from probes equally spaced up tree trunks and freshly cut live wood samples. (3)Beat frequencies observed while applying AC voltages to plants. (4)Plant length quantization. (5)Plant growth angle and voltage quantization with respect to the gravitational field. (6)The measurement of plant frequences with a low frequency spectrum analyzer which correlate with the frequencies observed by other means such as by measuring plant lengths, considered as half wavelengths, and beat frequencies. (7)Voltages obtained from insulated, isolated from light, diode dies placed in slits in tree trunks. Diodes become relatively low impedance sources for voltages as high as eight volts. Diodes indicate charge separating longitudinal standing waves sweeping up and down a tree trunk. Longitudinal waves also indicated by plant structure. (8)The measured discrete wave velocities appear to be dependent on their direction of travel with respect to the gravitational field. These provide growth references for the plant and a wave guide affect. For references see Wagner Research Laboratory Web Page.
NASA Astrophysics Data System (ADS)
Livingston, W.
The occasion of a total eclipse impacts the human observer with a bewildering rapid sequence of phenomena: mid-day cooling, failing light without accustomed color change, shadow-bands transiting the ground, cessation of bird sounds, possible frantic beating of jungle drums, Baily's beads, appearance of flame-like prominences, and most fantastic of all the solar corona. The author considers that although the corona is known to be 2 - 20(106)K, there is a lack of consensus on the heating mechanism, except the energy must be non-thermal and derived from surface and sub-surface convective motions. Theoreticians invoke the Joule dissipation of magnetic fields by Alfvén waves, electric currents in loop structures, or MHD turbulence. Although eclipse experiments to discriminate between these ideas generally fail, the sighting of 'plasmoids' was reported from the CFHT on Mauna Kea at the 1991 eclipse. Future experiments include: IR mapping of the coronal spectrum, spectroscopic velocity measurements, and the continued search for waves, nanoflares, and plasmoids.
Kervella, Gaël; Van Dijk, Frederic; Pillet, Grégoire; Lamponi, Marco; Chtioui, Mourad; Morvan, Loïc; Alouini, Mehdi
2015-08-01
We report on the stabilization of a 90-GHz millimeter-wave signal generated from a fully integrated photonic circuit. The chip consists of two DFB single-mode lasers whose optical signals are combined on a fast photodiode to generate a largely tunable heterodyne beat note. We generate an optical comb from each laser with a microwave synthesizer, and by self-injecting the resulting signal, we mutually correlate the phase noise of each DFB and stabilize the beatnote on a multiple of the frequency delivered by the synthesizer. The performances achieved beat note linewidth below 30 Hz.
Farrow, Darcie A; Smith, Eric R; Qian, Wei; Jonas, David M
2008-11-07
By analogy to the Raman depolarization ratio, vibrational quantum beats in pump-probe experiments depend on the relative pump and probe laser beam polarizations in a way that reflects vibrational symmetry. The polarization signatures differ from those in spontaneous Raman scattering because the order of field-matter interactions is different. Since pump-probe experiments are sensitive to vibrations on excited electronic states, the polarization anisotropy of vibrational quantum beats can also reflect electronic relaxation processes. Diagrammatic treatments, which expand use of the symmetry of the two-photon tensor to treat signal pathways with vibrational and vibronic coherences, are applied to find the polarization anisotropy of vibrational and vibronic quantum beats in pump-probe experiments for different stages of electronic relaxation in square symmetric molecules. Asymmetric vibrational quantum beats can be distinguished from asymmetric vibronic quantum beats by a pi phase jump near the center of the electronic spectrum and their disappearance in the impulsive limit. Beyond identification of vibrational symmetry, the vibrational quantum beat anisotropy can be used to determine if components of a doubly degenerate electronic state are unrelaxed, dephased, population exchanged, or completely equilibrated.
Beat gestures help preschoolers recall and comprehend discourse information.
Llanes-Coromina, Judith; Vilà-Giménez, Ingrid; Kushch, Olga; Borràs-Comes, Joan; Prieto, Pilar
2018-08-01
Although the positive effects of iconic gestures on word recall and comprehension by children have been clearly established, less is known about the benefits of beat gestures (rhythmic hand/arm movements produced together with prominent prosody). This study investigated (a) whether beat gestures combined with prosodic information help children recall contrastively focused words as well as information related to those words in a child-directed discourse (Experiment 1) and (b) whether the presence of beat gestures helps children comprehend a narrative discourse (Experiment 2). In Experiment 1, 51 4-year-olds were exposed to a total of three short stories with contrastive words presented in three conditions, namely with prominence in both speech and gesture, prominence in speech only, and nonprominent speech. Results of a recall task showed that (a) children remembered more words when exposed to prominence in both speech and gesture than in either of the other two conditions and that (b) children were more likely to remember information related to those words when the words were associated with beat gestures. In Experiment 2, 55 5- and 6-year-olds were presented with six narratives with target items either produced with prosodic prominence but no beat gestures or produced with both prosodic prominence and beat gestures. Results of a comprehension task demonstrated that stories told with beat gestures were comprehended better by children. Together, these results constitute evidence that beat gestures help preschoolers not only to recall discourse information but also to comprehend it. Copyright © 2018 Elsevier Inc. All rights reserved.
The Simplest Demonstration on Acoustic Beats
ERIC Educational Resources Information Center
Ganci, Alessio; Ganci, Salvatore
2015-01-01
The classical demonstration experiment on acoustic beats using two signal generators and a dual trace oscilloscope is an important ingredient in teaching the subject. This short laboratory note aims to point out what may be the simplest demonstrative experiment on acoustic beats to carry out in a classroom without employing any lab apparatus.
Methods and apparatus for moving and separating materials exhibiting different physical properties
Peterson, Stephen C.; Brimhall, Owen D.; McLaughlin, Thomas J.; Baker, Charles D.; Sparks, Sam L.
1991-01-01
Methods and apparatus for controlling the movement of materials having different physical properties when one of the materials is a fluid. The invention does not rely on flocculation, sedimentation, centrifugation, the buoyancy of the materials, or any other gravity dependent characteristic, in order to achieve its desired results. The methods of the present invention provide that a first acoustic wave is propagated through a vessel containing the materials. A second acoustic wave, at a frequency different than the first acoustic wave, is also propagated through the vessel so that the two acoustic waves are superimposed upon each other. The superimposition of the two waves creates a beat frequency wave. The beat frequency wave comprises pressure gradients dividing regions of maximum and minimum pressure. The pressure gradients and the regions of maximum and minimum pressure move through space and time at a group velocity. The moving pressure gradients and regions of maximum and minimum pressure act upon the materials so as to move one of the materials towards a predetermined location in the vessel. The present invention provides that the materials may be controllably moved toward a location, aggregated at a particular location, or physically separated from each other.
Methods and apparatus for moving and separating materials exhibiting different physical properties
Peterson, Stephen C.; Brimhall, Owen D.; McLaughlin, Thomas J.; Baker, Charles D.; Sparks, Sam L.
1988-01-01
Methods and apparatus for controlling the movement of materials having different physical properties when one of the materials is a fluid. The invention does not rely on flocculation, sedimentation, centrifugation, the buoyancy of the materials, or any other gravity dependent characteristic, in order to achieve its desired results. The methods of the present invention provide that a first acoustic wave is progpagated through a vessel containing the materials. A second acoustic wave, at a frequency different than the first acoustic wave, is also propagated through the vessel so that the two acoustic waves are superimposed upon each other. The superimposition of the two waves creates a beat frequency wave. The beat frequency wave comprises pressure gradients dividing regions of maximum and minimum pressure. The pressure gradients and the regions of maximum and minimum pressure move through space and time at a group velocity. The moving pressure gradients and regions of maximum and minimum pressure act upon the marterials so as to move one of the materials towards a predetermined location in the vessel. The present invention provides that the materials may be controllably moved toward a location, aggreated at a particular location, or physically separated from each other.
NASA Astrophysics Data System (ADS)
Hematizadeh, Ayoob; Jazayeri, Seyed Masud; Ghafary, Bijan
2018-02-01
A scheme for excitation of terahertz (THz) radiation is presented by photo mixing of two super-Gaussian laser beams in a rippled density collisional magnetized plasma. Lasers having different frequencies and wave numbers but the same electric fields create a ponderomotive force on the electrons of plasma in the beating frequency. Super-Gaussian laser beam has the exclusive features such as steep gradient in laser intensity distribution, wider cross-section in comparison with Gaussian profiles, which make stronger ponderomotive force and higher THz radiation. The magnetic field is considered oblique to laser beams propagation direction; in this case, depending on the phase matching conditions different mode waves can propagate in plasma. It is found that amplitude and efficiency of the emitted THz radiation not only are sensitive to the beating frequency, collision frequency, and magnetic field strength but to the angle between laser beams and static magnetic field. The efficiency of THz radiation can be optimized in a certain angle.
What makes a rhythm complex? The influence of musical training and accent type on beat perception
Burgoyne, J. Ashley; Odijk, Daan; Honing, Henkjan; Grahn, Jessica A.
2018-01-01
Perception of a regular beat in music is inferred from different types of accents. For example, increases in loudness cause intensity accents, and the grouping of time intervals in a rhythm creates temporal accents. Accents are expected to occur on the beat: when accents are “missing” on the beat, the beat is more difficult to find. However, it is unclear whether accents occurring off the beat alter beat perception similarly to missing accents on the beat. Moreover, no one has examined whether intensity accents influence beat perception more or less strongly than temporal accents, nor how musical expertise affects sensitivity to each type of accent. In two experiments, we obtained ratings of difficulty in finding the beat in rhythms with either temporal or intensity accents, and which varied in the number of accents on the beat as well as the number of accents off the beat. In both experiments, the occurrence of accents on the beat facilitated beat detection more in musical experts than in musical novices. In addition, the number of accents on the beat affected beat finding more in rhythms with temporal accents than in rhythms with intensity accents. The effect of accents off the beat was much weaker than the effect of accents on the beat and appeared to depend on musical expertise, as well as on the number of accents on the beat: when many accents on the beat are missing, beat perception is quite difficult, and adding accents off the beat may not reduce beat perception further. Overall, the different types of accents were processed qualitatively differently, depending on musical expertise. Therefore, these findings indicate the importance of designing ecologically valid stimuli when testing beat perception in musical novices, who may need different types of accent information than musical experts to be able to find a beat. Furthermore, our findings stress the importance of carefully designing rhythms for social and clinical applications of beat perception, as not all listeners treat all rhythms alike. PMID:29320533
What makes a rhythm complex? The influence of musical training and accent type on beat perception.
Bouwer, Fleur L; Burgoyne, J Ashley; Odijk, Daan; Honing, Henkjan; Grahn, Jessica A
2018-01-01
Perception of a regular beat in music is inferred from different types of accents. For example, increases in loudness cause intensity accents, and the grouping of time intervals in a rhythm creates temporal accents. Accents are expected to occur on the beat: when accents are "missing" on the beat, the beat is more difficult to find. However, it is unclear whether accents occurring off the beat alter beat perception similarly to missing accents on the beat. Moreover, no one has examined whether intensity accents influence beat perception more or less strongly than temporal accents, nor how musical expertise affects sensitivity to each type of accent. In two experiments, we obtained ratings of difficulty in finding the beat in rhythms with either temporal or intensity accents, and which varied in the number of accents on the beat as well as the number of accents off the beat. In both experiments, the occurrence of accents on the beat facilitated beat detection more in musical experts than in musical novices. In addition, the number of accents on the beat affected beat finding more in rhythms with temporal accents than in rhythms with intensity accents. The effect of accents off the beat was much weaker than the effect of accents on the beat and appeared to depend on musical expertise, as well as on the number of accents on the beat: when many accents on the beat are missing, beat perception is quite difficult, and adding accents off the beat may not reduce beat perception further. Overall, the different types of accents were processed qualitatively differently, depending on musical expertise. Therefore, these findings indicate the importance of designing ecologically valid stimuli when testing beat perception in musical novices, who may need different types of accent information than musical experts to be able to find a beat. Furthermore, our findings stress the importance of carefully designing rhythms for social and clinical applications of beat perception, as not all listeners treat all rhythms alike.
Demir, Aslan; Türker, Polat; Bozkurt, Suheyla Uyar; İlker, Yalcin Nazmi
2015-01-01
In this animal study, we reviewed the histomorphological findings in rabbit kidneys after a high number of high-energy shock wave applications and observed if there were any cumulative effects after repeated sessions. We formed 2 groups, each consisting of 8 rabbits. Group 1 received 1 session and group 2 received 3 sessions of ESWL with a 7 day interval between sessions, consisting of 3500 beats to the left kidney and 5500 beats to the right kidney per session. The specimens of kidneys were examined histomorphologically after bilateral nephrectomy was performed. For statistical analysis, 4 groups of specimens were formed. The first and second groups received 1 session, 3500 and 5500 beats, respectively. The third and fourth groups received 3 sessions, at 3500 and 5500 beats per each session, respectively. The sections were evaluated under a light microscope to determine subcapsular thickening; subcapsular, intratubular and parenchymal hemorrhage; subcapsular, intersitital, perivascular and proximal ureteral fibrosis; paranchymal necrosis; tubular epithelial vacuolization; tubular atrophy; glomerular destruction and calcification. In histopathological examinations capsular thickening, subcapsular hematoma, tubuloepithelial vacuolisation, glomerular destruction, parenchymal hemorrhage, interstitial fibrosis, and perivascular fibrosis were observed in all groups. In statistical analysis, on the basis of perivascular fibrosis and tubular atrophy, there was a beats per session dependent increase of both. The detrimental effects from ESWL are dose dependent but not cumulative for up to 3 sessions. Histopathological experimental animal studies will aid in understanding local and maybe, by means of these local effects, systemic effects.
Accurate and Standardized Coronary Wave Intensity Analysis.
Rivolo, Simone; Patterson, Tiffany; Asrress, Kaleab N; Marber, Michael; Redwood, Simon; Smith, Nicolas P; Lee, Jack
2017-05-01
Coronary wave intensity analysis (cWIA) has increasingly been applied in the clinical research setting to distinguish between the proximal and distal mechanical influences on coronary blood flow. Recently, a cWIA-derived clinical index demonstrated prognostic value in predicting functional recovery postmyocardial infarction. Nevertheless, the known operator dependence of the cWIA metrics currently hampers its routine application in clinical practice. Specifically, it was recently demonstrated that the cWIA metrics are highly dependent on the chosen Savitzky-Golay filter parameters used to smooth the acquired traces. Therefore, a novel method to make cWIA standardized and automatic was proposed and evaluated in vivo. The novel approach combines an adaptive Savitzky-Golay filter with high-order central finite differencing after ensemble-averaging the acquired waveforms. Its accuracy was assessed using in vivo human data. The proposed approach was then modified to automatically perform beat wise cWIA. Finally, the feasibility (accuracy and robustness) of the method was evaluated. The automatic cWIA algorithm provided satisfactory accuracy under a wide range of noise scenarios (≤10% and ≤20% error in the estimation of wave areas and peaks, respectively). These results were confirmed when beat-by-beat cWIA was performed. An accurate, standardized, and automated cWIA was developed. Moreover, the feasibility of beat wise cWIA was demonstrated for the first time. The proposed algorithm provides practitioners with a standardized technique that could broaden the application of cWIA in the clinical practice as enabling multicenter trials. Furthermore, the demonstrated potential of beatwise cWIA opens the possibility investigating the coronary physiology in real time.
Järverud, K; Ollmar, S; Brodin, L A
2002-09-01
Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, sinus rhythm 100.3 +/- 16.5 beats min(-1), average impedance 629.8 +/- 72.6 ohms; and two dogs: 30 kg each, sinus rhythm 86.0 beats min(-1), 862.1 ohms and 134.0 beats min(-1), 1114.6 ohms, respectively). The averaged curve and standard deviation curve of the impedance in sinus rhythm were analysed in MATLAB to clarify and study consistent impedance shape over one heart cycle. In eight of nine (89%) animal subjects, a consistent impedance slope change (notch) was observed in the early stage of the cardiac filling phase. This result was reproduced in an additional subject with simultaneous echocardiographical measurements of mitral valve blood flow. The notch occured soon after rapid early filling (E-wave in mitral flow) but prior to ventricular filling caused by atrial contraction, indicating that the impedance notch was caused by rapid ventricular filling and that it might be a sensed feature of diagnostic value. The intracardiac impedance notch in the present study had similar features to the non-invasive transthoracic impedance O-wave reported by others, and it is shown here that an O-wave is found in intracardiac impedance signals, strongly suggesting that the non-invasive O-wave is caused by cardiac events.
Laser beat wave resonant terahertz generation in a magnetized plasma channel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhasin, Lalita; Tripathi, V. K.; Kumar, Pawan, E-mail: kumarpawan-30@yahoo.co.in
Resonant excitation of terahertz (THz) radiation by nonlinear mixing of two lasers in a ripple-free self created plasma channel is investigated. The channel has a transverse static magnetic field and supports a THz X-mode with phase velocity close to the speed of light in vacuum when the frequency of the mode is close to plasma frequency on the channel axis and its value decreases with the intensity of lasers. The THz is resonantly driven by the laser beat wave ponderomotive force. The THz amplitude scales almost three half power of the intensity of lasers as the width of the THzmore » eigen mode shrinks with laser intensity.« less
EEG-based alpha neurofeedback training for mood enhancement.
Phneah, Swee Wu; Nisar, Humaira
2017-06-01
The aim of this paper is to develop a preliminary neurofeedback system to improve the mood of the subjects using audio signals by enhancing their alpha brainwaves. Assessment of the effect of music on the human subjects is performed using three methods; subjective assessment of mood with the help of a questionnaire, the effect on brain by analysing EEG signals, and the effect on body by physiological assessment. In this study, two experiments have been designed. The first experiment was to determine the short-term effect of music on soothing human subjects, whereas the second experiment was to determine its long-term effect. Two types of music were used in the first experiment, the favourite music selected by the participants and a relaxing music with alpha wave binaural beats. The research findings showed that the relaxing music has a better soothing effect on the participants psychologically and physiologically. However, the one-way analysis of variance (ANOVA) results showed that the short-term soothing effect of both favourite music and relaxing music was not significant in changing the mean alpha absolute power and mean physiological measures (blood pressure and heart rate) at the significance level of 0.05. The second experiment was somewhat similar to an alpha neurofeedback training whereby the participants trained their brains to produce more alpha brainwaves by listening to the relaxing music with alpha wave binaural beats for a duration of 30 min daily. The results showed that the relaxing music has a long-term psychological and physiological effect on soothing the participants, as can be observed from the increase in alpha power and decrease in physiological measures after each session of training. The training was found to be effective in increasing the alpha power significantly [F(2,12) = 11.5458 and p = 0.0016], but no significant reduction in physiological measures was observed at the significance level of 0.05.
Ultrafast Narrow Band Modulation of VCSELs
NASA Technical Reports Server (NTRS)
Ning, Cun-Zheng; Biegel, Bryan A. (Technical Monitor)
2002-01-01
Multimode beating was greatly enhanced by taking output from part (e.g., half) of the output facet. Simpler sources of microwaves and millimeter waves of various frequencies were generated by varying the VCSEL diameter in a single multimode VCSEL our coupling of a few VCSELs. Breathing frequency in multi-mode operations affects modulation response and bandwidth. Optimizing RO frequency and mode beating frequency could potentially expand bandwidths suitable for wide band digital communications.
Rompolas, Panteleimon; Patel-King, Ramila S.
2010-01-01
Motile cilia mediate the flow of mucus and other fluids across the surface of specialized epithelia in metazoans. Efficient clearance of peri-ciliary fluids depends on the precise coordination of ciliary beating to produce metachronal waves. The role of individual dynein motors and the mechanical feedback mechanisms required for this process are not well understood. Here we used the ciliated epithelium of the planarian Schmidtea mediterranea to dissect the role of outer arm dynein motors in the metachronal synchrony of motile cilia. We demonstrate that animals that completely lack outer dynein arms display a significant decline in beat frequency and an inability of cilia to coordinate their oscillations and form metachronal waves. Furthermore, lack of a key mechanosensitive regulatory component (LC1) yields a similar phenotype even though outer arms still assemble in the axoneme. The lack of metachrony was not due simply to a decrease in ciliary beat frequency, as reducing this parameter by altering medium viscosity did not affect ciliary coordination. In addition, we did not observe a significant temporal variability in the beat cycle of impaired cilia. We propose that this conformational switch provides a mechanical feedback system within outer arm dynein that is necessary to entrain metachronal synchrony. PMID:20844081
Becher, Ann-Katrin; Höhne, Marlene; Axmacher, Nikolai; Chaieb, Leila; Elger, Christian E; Fell, Juergen
2015-01-01
Auditory stimulation with monaural or binaural auditory beats (i.e. sine waves with nearby frequencies presented either to both ears or to each ear separately) represents a non-invasive approach to influence electrical brain activity. It is still unclear exactly which brain sites are affected by beat stimulation. In particular, an impact of beat stimulation on mediotemporal brain areas could possibly provide new options for memory enhancement or seizure control. Therefore, we examined how electroencephalography (EEG) power and phase synchronization are modulated by auditory stimulation with beat frequencies corresponding to dominant EEG rhythms based on intracranial recordings in presurgical epilepsy patients. Monaural and binaural beat stimuli with beat frequencies of 5, 10, 40 and 80 Hz and non-superposed control signals were administered with low amplitudes (60 dB SPL) and for short durations (5 s). EEG power was intracranially recorded from mediotemporal, temporo-basal and temporo-lateral and surface sites. Evoked and total EEG power and phase synchronization during beat vs. control stimulation were compared by the use of Bonferroni-corrected non-parametric label-permutation tests. We found that power and phase synchronization were significantly modulated by beat stimulation not only at temporo-basal, temporo-lateral and surface sites, but also at mediotemporal sites. Generally, more significant decreases than increases were observed. The most prominent power increases were seen after stimulation with monaural 40-Hz beats. The most pronounced power and synchronization decreases resulted from stimulation with monaural 5-Hz and binaural 80-Hz beats. Our results suggest that beat stimulation offers a non-invasive approach for the modulation of intracranial EEG characteristics. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Four-Wave Mixing of Gigawatt Power, Long-Wave Infrared Radiation in Gases and Semiconductors
NASA Astrophysics Data System (ADS)
Pigeon, Jeremy James
The nonlinear optics of gigawatt power, 10 microm, 3 and 200 ps long pulses propagating in gases and semiconductors has been studied experimentally and numerically. In this work, the development of a high-repetition rate, picosecond, CO2 laser system has enabled experiments using peak intensities in the range of 1-10 GW/cm2, approximately one thousand times greater than previous nonlinear optics experiments in the long-wave infrared (LWIR) spectral region. The first measurements of the nonlinear refractive index of the atomic and molecular gases Kr, Xe, N2, O2 and the air at a wavelength near 10 microm were accomplished by studying the four-wave mixing (FWM) of dual-wavelength, 200 ps CO2 laser pulses. These measurements indicate that the nonlinearities of the diatomic molecules N2, O2 and the air are dominated by the molecular contribution to the nonlinear refractive index. Supercontinuum (SC) generation covering the infrared spectral range, from 2-20 microm, was realized by propagating 3 ps, 10 microm pulses in an approximately 7 cm long, Cr-doped GaAs crystal. Temporal measurements of the SC radiation show that pulse splitting accompanies the generation of such broadband light in GaAs. The propagation of 3 ps, 10 microm pulses in GaAs was studied numerically by solving the Generalized Nonlinear Schrodinger Equation (GNLSE). These simulations, combined with analytic estimates, were used to determine that stimulated Raman scattering combined with a modulational instability caused by the propagation of intense LWIR radiation in the negative group velocity dispersion region of GaAs are responsible for the SC generation process. The multiple FWM of a 106 GHz, 200 ps CO2 laser beat-wave propagating in GaAs was used to generate a broadband FWM spectrum that was compressed by the negative group velocity dispersion of GaAs and NaCl crystals to form trains of high-power, picosecond pulses at a wavelength near 10 microm. Experimental FWM spectra obtained using 165 and 882 GHz beat-waves revealed an unexpected and rapid decrease in the FWM yield that was not predicted by the GNLSE model that accounts for third-order nonlinearities alone. These results suggest that the effective nonlinear refractive index of GaAs, having formidable second- and third-order susceptibilities, may be altered by quadratic nonlinearities.
Terahertz transmission properties of silicon wafers using continuous-wave terahertz spectroscopy
NASA Astrophysics Data System (ADS)
Kim, Chihoon; Ahn, Jae Sung; Ji, Taeksoo; Eom, Joo Beom
2017-04-01
We present the spectral properties of Si wafers using continuous-wave terahertz (CW-THz) spectroscopy. By using a tunable laser source and a fixed distributed-feedback laser diode (DFB-LD), a stably tunable beat source for CW-THz spectroscopy system can be implemented. THz radiation is generated in the frequency range of 100 GHz-800 GHz by photomixing in a photoconductive antenna. We also measured CW-THz waveforms by changing the beat frequency and confirmed repeatability through repeated measurement. We calculated the peaks of the THz frequency by taking fast Fourier transforms (FFTs) of measured THz waveforms. The feasibility of CW-THz spectroscopy is demonstrated by the THz spectra of Si wafers with different resistivities, mobilities, and carrier concentrations. The results show that Si wafers with a lower resistivity absorb more THz waves. Thus, we expect our CW-THz system to have the advantage of being able to perform fast non-destructive analysis.
Liao, Duanping; Shaffer, Michele L.; He, Fan; Rodriguez-Colon, Sol; Wu, Rongling; Whitsel, Eric A.; Bixler, Edward O.; Cascio, Wayne E.
2011-01-01
The acute effects and the time course of fine particulate pollution (PM2.5) on atrial fibrillation/flutter (AF) predictors, including P-wave duration, PR interval duration, and P-wave complexity, were investigated in a community-dwelling sample of 106 nonsmokers. Individual-level 24-h beat-to-beat electrocardiogram (ECG) data were visually examined. After identifying and removing artifacts and arrhythmic beats, the 30-min averages of the AF predictors were calculated. A personal PM2.5 monitor was used to measure individual-level, real-time PM2.5 exposures during the same 24-h period, and corresponding 30-min average PM2.5 concentration were calculated. Under a linear mixed-effects modeling framework, distributed lag models were used to estimate regression coefficients (βs) associating PM2.5 with AF predictors. Most of the adverse effects on AF predictors occurred within 1.5–2 h after PM2.5 exposure. The multivariable adjusted βs per 10-µg/m3 rise in PM2.5 at lag 1 and lag 2 were significantly associated with P-wave complexity. PM2.5 exposure was also significantly associated with prolonged PR duration at lag 3 and lag 4. Higher PM2.5 was found to be associated with increases in P-wave complexity and PR duration. Maximal effects were observed within 2 h. These findings suggest that PM2.5 adversely affects AF predictors; thus, PM2.5 may be indicative of greater susceptibility to AF. PMID:21480044
Grose, John H; Mamo, Sara K
2012-01-01
The purpose of this study was to determine the reliability of the electrophysiological binaural beat steady state response as a gauge of temporal fine structure coding, particularly as it relates to the aging auditory system. The hypothesis was that the response would be more robust in a lower, than in a higher, frequency region and in younger, than in older, adults. Two experiments were undertaken. The first measured the 40 Hz binaural beat steady state response elicited by tone pairs in two frequency regions: lower (390 and 430 Hz tone pair) and higher (810 and 850 Hz tone pair). Frequency following responses (FFRs) evoked by the tones were also recorded. Ten young adults with normal hearing participated. The second experiment measured the binaural beat and FFRs in older adults but only in the lower frequency region. Fourteen older adults with relatively normal hearing participated. Response metrics in both experiments included response component signal-to-noise ratio (F statistic) and magnitude-squared coherence. Experiment 1 showed that FFRs were elicited in both frequency regions but were more robust in the lower frequency region. Binaural beat responses elicited by the lower frequency pair of tones showed greater amplitude fluctuation within a participant than the respective FFRs. Experiment 2 showed that older adults exhibited similar FFRs to younger adults, but proportionally fewer older participants showed binaural beat responses. Age differences in onset responses were also observed. The lower prevalence of the binaural beat response in older adults, despite the presence of FFRs, provides tentative support for the sensitivity of this measure to age-related deficits in temporal processing. However, the lability of the binaural beat response advocates caution in its use as an objective measure of fine structure coding.
RUSSO, VINCENZO; DI MEO, FEDERICA; PAPA, ANDREA ANTONIO; CIOPPA, NADIA DELLA; PROIETTI, RICCARDO; RUSSO, MARIA GIOVANNA; CALABRÒ, RAFFAELE; POLITANO, LUISA
2014-01-01
P-wave dispersion is a non invasive indicator of intra-atrial conduction heterogeneity producing substrate for reentry, which is a pathophysiological mechanism of atrial fibrillation. The relationship between P-wave dispersion (PD) and atrial fibrillation (AF) in Myotonic dystrophy type 1 (DM1) patients is still unclear. Atrial Preference Pacing (APP) is an efficient algorithm to prevent paroxysmal AF in patients implanted with dual-chamber pacemaker. Aim of our study was to evaluate the possible correlation between atrial preference pacing algorithm, P-wave dispersion and AF burden in DM1 patients with normal cardiac function underwent permanent dual-chamber pacemaker implantation. We enrolled 50 patients with DM1 (age 50.3 ± 7.3; 11 F) underwent dual-chamber pacemaker implantation for various degree of atrioventricula block. The study population was randomized following 1 months stabilization period to APP algorithm features programmed OFF or ON. Patients were assessed every 3 months for the first year, and every 6 months thereafter up to 3 years. At each follow-up visit, we counted: the number of premature atrial beats, the number and the mean duration of AF episodes, AF burden and the percentage of atrial and ventricular pacing. APP ON Group showed lower number of AF episodes (117 ± 25 vs. 143 ± 37; p = 0.03) and AF burden (3059 ± 275 vs. 9010 ± 630 min; p < 0.04) than APP OFF Group. Atrial premature beats count (44903 ± 30689 vs. 13720 ± 7717 beats; p = 0.005) and Pwave dispersion values (42,1 ± 11 ms vs. 29,1 ± 4,2 ms, p = 0,003) were decreased in APP ON Group. We found a significant positive correlation between PD and AF burden (R = 0,8, p = 0.007). Atrial preference pacing algorithm, decreasing the number of atrial premature beats and the P-wave dispersion, reduces the onset and perpetuator factors of AF episodes and decreases the AF burden in DM1 patients underwent dual chamber pacemaker implantation for various degree of atrioventricular blocks and documented atrial fibrillation. PMID:25873781
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Yanpeng; Department of Electronic Science and Technology, Xi'an Jiaotong University, Xi'an 710049; Gan Chenli
2006-05-15
We investigate the color-locked twin-noisy-field correlation effects in third-order nonlinear absorption and dispersion of ultrafast polarization beats. We demonstrate a phase-sensitive method for studying the two-photon nondegenerate four-wave mixing (NDFWM) due to atomic coherence in a multilevel system. The reference signal is another one-photon degenerate four-wave-mixing signal, which propagates along the same optical path as the NDFWM signal. This method is used for studying the phase dispersion of the third-order susceptibility and for the optical heterodyne detection of the NDFWM signal. The third-order nonlinear response can be controlled and modified through the color-locked correlation of twin noisy fields.
Hayakawa, Tomohiro; Kunihiro, Takeshi; Dowaki, Suguru; Uno, Hatsume; Matsui, Eriko; Uchida, Masashi; Kobayashi, Seiji; Yasuda, Akio; Shimizu, Tatsuya; Okano, Teruo
2012-01-01
A noninvasive method for the characterization of cardiomyocyte contractile behavior is presented. Light microscopic video images of cardiomyocytes were captured with a high-speed camera, and motion vectors (which have a velocity dimension) were calculated with a high spatiotemporal resolution using a block-matching algorithm. This method could extract contraction and relaxation motions of cardiomyocytes separately and evaluate characteristics such as the beating rate, orientation of contraction, beating cooperativity/homogeneity in the monolayer, and wave propagation of impulses. Simultaneous phase-contrast imaging and calcium (Ca2+) fluorescence measurements confirmed that the timing of the maximum shortening velocity of cardiomyocytes correlated well with intracellular Ca2+ transients. Based on our analysis, gap junction inhibitors, 1-heptanol (2 mM) or 18-β-glycyrrhetinic acid (30 μM), resulted in clear changes in beating cooperativity and the propagation pattern of impulses in the cardiomyocyte monolayer. Additionally, the time dependence of the motion vector length indicated a prolonged relaxation process in the presence of potassium (K+) channel blockers, dl-sotalol (1 μM), E-4031 (100 nM), or terfenadine (100 nM), reflecting the prolonged QT (Q wave and T wave) interval of cardiomyocytes. Effects of autonomic agents (acetylcholine or epinephrine [EPI]) or EPI and propranolol on cardiomyocytes were clearly detected by the alterations of beating rate and the motion vector length in contraction and relaxation processes. This method was noninvasive and could sensitively evaluate the contractile behavior of cardiomyocytes; therefore, it may be used to study and/or monitor cardiomyocyte tissue during prolonged culture periods and in screens for drugs that may alter the contraction of cardiomyocytes.
Khine, Htet W; Steding-Ehrenborg, Katarina; Hastings, Jeffrey L; Kowal, Jamie; Daniels, James D; Page, Richard L; Goldberger, Jeffery J; Ng, Jason; Adams-Huet, Beverley; Bungo, Michael W; Levine, Benjamin D
2018-05-01
The prevalence of atrial fibrillation (AF) in active astronauts is ≈5%, similar to the general population but at a younger age. Risk factors for AF include left atrial enlargement, increased number of premature atrial complexes, and certain parameters on signal-averaged electrocardiography, such as P-wave duration, root mean square voltage for the terminal 20 ms of the signal-averaged P wave, and P-wave amplitude. We aimed to evaluate changes in atrial structure, supraventricular beats, and atrial electrophysiology to determine whether spaceflight could increase the risk of AF. Thirteen astronauts underwent cardiac magnetic resonance imaging to assess atrial structure and function before and after 6 months in space and high-resolution Holter monitoring for multiple 48-hour time periods before flight, during flight, and on landing day. Left atrial volume transiently increased after 6 months in space (12±18 mL; P =0.03) without changing atrial function. Right atrial size remained unchanged. No changes in supraventricular beats were noted. One astronaut had a large increase in supraventricular ectopic beats but none developed AF. Filtered P-wave duration did not change over time, but root mean square voltage for the terminal 20 ms decreased on all fight days except landing day. No changes in P-wave amplitude were seen in leads II or V 1 except landing day for lead V 1 . Six months of spaceflight may be sufficient to cause transient changes in left atrial structure and atrial electrophysiology that increase the risk of AF. However, there was no definite evidence of increased supraventricular arrhythmias and no identified episodes of AF. © 2018 American Heart Association, Inc.
Hunting for the beat in the body: on period and phase locking in music-induced movement.
Burger, Birgitta; Thompson, Marc R; Luck, Geoff; Saarikallio, Suvi H; Toiviainen, Petri
2014-01-01
Music has the capacity to induce movement in humans. Such responses during music listening are usually spontaneous and range from tapping to full-body dancing. However, it is still unclear how humans embody musical structures to facilitate entrainment. This paper describes two experiments, one dealing with period locking to different metrical levels in full-body movement and its relationships to beat- and rhythm-related musical characteristics, and the other dealing with phase locking in the more constrained condition of sideways swaying motions. Expected in Experiment 1 was that music with clear and strong beat structures would facilitate more period-locked movement. Experiment 2 was assumed to yield a common phase relationship between participants' swaying movements and the musical beat. In both experiments optical motion capture was used to record participants' movements. In Experiment 1 a window-based period-locking probability index related to four metrical levels was established, based on acceleration data in three dimensions. Subsequent correlations between this index and musical characteristics of the stimuli revealed pulse clarity to be related to periodic movement at the tactus level, and low frequency flux to mediolateral and anteroposterior movement at both tactus and bar levels. At faster tempi higher metrical levels became more apparent in participants' movement. Experiment 2 showed that about half of the participants showed a stable phase relationship between movement and beat, with superior-inferior movement most often being synchronized to the tactus level, whereas mediolateral movement was rather synchronized to the bar level. However, the relationship between movement phase and beat locations was not consistent between participants, as the beat locations occurred at different phase angles of their movements. The results imply that entrainment to music is a complex phenomenon, involving the whole body and occurring at different metrical levels.
Psychoacoustic Factors in Musical Intonation: Beats, Interval Tuning, and Inharmonicity.
NASA Astrophysics Data System (ADS)
Keislar, Douglas Fleming
Three psychoacoustic experiments were conducted using musically experienced subjects. In the first two experiments, the interval tested was the perfect fifth F4-C5; in the final one it was the major third F4-A4. The beat rate was controlled by two different methods: (1) simply retuning the interval, and (2) frequency-shifting one partial of each pair of beating partials without changing the overall interval tuning. The second method introduces inharmonicity. In addition, two levels of beat amplitude were introduced by using either a complete spectrum of 16 equal-amplitude partials per note, or by deleting one partial from each pair of beating partials. The results of all three experiments indicate that, for these stimuli, beating does not contribute significantly to the percept of "out-of-tuneness," because it made no difference statistically whether the beat amplitude was maximal or minimal. By contrast, mistuning the interval was highly significant. For the fifths, frequency-shifting the appropriate partials had about as much effect on the perceived intonation as mistuning the interval. For thirds, this effect was weaker, presumably since there were fewer inharmonic partials and they were higher in the harmonic series. Subjects were less consistent in their judgments of thirds than of fifths, perhaps because the equal-tempered and just thirds differ noticeably, unlike fifths. Since it is unlikely that beats would be more audible in real musical situations than under these laboratory conditions, these results suggest that the perception of intonation in music is dependent on the actual interval tuning rather than the concomitant beat rate. If beating partials are unimportant vis-a-vis interval tuning, this strengthens the argument for a cultural basis for musical intonation and scales, as opposed to the acoustical basis set forth by Helmholtz and others.
Influence of mode-beating pulse on laser-induced plasma
NASA Astrophysics Data System (ADS)
Nishihara, M.; Freund, J. B.; Glumac, N. G.; Elliott, G. S.
2018-04-01
This paper addresses the influence of mode-beating pulse on laser-induced plasma. The second harmonic of a Nd:YAG laser, operated either with the single mode or multimode, was used for non-resonant optical breakdown, and subsequent plasma development was visualized using a streak imaging system. The single mode lasing leads to a stable breakdown location and smooth envelopment of the plasma boundary, while the multimode lasing, with the dominant mode-beating frequency of 500-800 MHz, leads to fluctuations in the breakdown location, a globally modulated plasma surface, and growth of local microstructures at the plasma boundary. The distribution of the local inhomogeneity was measured from the elastic scattering signals on the streak image. The distance between the local structures agreed with the expected wavelength of hydrodynamic instability development due to the interference between the surface excited wave and transmitted wave. A numerical simulation, however, indicates that the local microstructure could also be directly generated at the peaks of the higher harmonic components if the multimode pulse contains up to the eighth harmonic of the fundamental cavity mode.
The occurrence of individual slow waves in sleep is predicted by heart rate
Mensen, Armand; Zhang, Zhongxing; Qi, Ming; Khatami, Ramin
2016-01-01
The integration of near-infrared spectroscopy and electroencephalography measures presents an ideal method to study the haemodynamics of sleep. While the cortical dynamics and neuro-modulating influences affecting the transition from wakefulness to sleep is well researched, the assumption has been that individual slow waves, the hallmark of deep sleep, are spontaneously occurring cortical events. By creating event-related potentials from the NIRS recording, time-locked to the onset of thousands of individual slow waves, we show the onset of slow waves is phase-locked to an ongoing oscillation in the NIRS recording. This oscillation stems from the moment to moment fluctuations of light absorption caused by arterial pulsations driven by the heart beat. The same oscillating signal can be detected if the electrocardiogram is time-locked to the onset of the slow wave. The ongoing NIRS oscillation suggests that individual slow wave initiation is dependent on that signal, and not the other way round. However, the precise causal links remain speculative. We propose several potential mechanisms: that the heart-beat or arterial pulsation acts as a stimulus which evokes a down-state; local fluctuations in energy supply may lead to a network effect of hyperpolarization; that the arterial pulsations lead to corresponding changes in the cerebral-spinal-fluid which evokes the slow wave; or that a third neural generator, regulating heart rate and slow waves may be involved. PMID:27445083
Human sperm steer with second harmonics of the flagellar beat.
Saggiorato, Guglielmo; Alvarez, Luis; Jikeli, Jan F; Kaupp, U Benjamin; Gompper, Gerhard; Elgeti, Jens
2017-11-10
Sperm are propelled by bending waves traveling along their flagellum. For steering in gradients of sensory cues, sperm adjust the flagellar waveform. Symmetric and asymmetric waveforms result in straight and curved swimming paths, respectively. Two mechanisms causing spatially asymmetric waveforms have been proposed: an average flagellar curvature and buckling. We image flagella of human sperm tethered with the head to a surface. The waveform is characterized by a fundamental beat frequency and its second harmonic. The superposition of harmonics breaks the beat symmetry temporally rather than spatially. As a result, sperm rotate around the tethering point. The rotation velocity is determined by the second-harmonic amplitude and phase. Stimulation with the female sex hormone progesterone enhances the second-harmonic contribution and, thereby, modulates sperm rotation. Higher beat frequency components exist in other flagellated cells; therefore, this steering mechanism might be widespread and could inspire the design of synthetic microswimmers.
Electromuscular incapacitating devices discharge and risk of severe bradycardia.
Havranek, Stepan; Neuzil, Petr; Linhart, Ales
2015-06-01
Electromuscular incapacitating devices (EMDs) are high-voltage, low-current stimulators causing involuntary muscle contractions and sensory response. Existing evidence about cardiac effects of EMD remains inconclusive. The aim of our study was to analyze electrocardiographic, echocardiographic, and microvolt T-wave alternans (MTWA) changes induced by EMD discharge.We examined 26 volunteers (22 men; median age 30 years) who underwent single standard 5-second duration exposure to TASER X26 under continuous echocardiographic and electrocardiographic monitoring. Microvolt T-wave alternans testing was performed at baseline (MTWA-1), as well as immediately and 60 minutes after EMD exposure (MTWA-2 and MTWA-3, respectively).Mean heart rate (HR) increased significantly from 88 ± 17 beats per minute before to 129 ± 17 beats per minute after exposure (P < 0.001). However, in 2 individuals, an abrupt decrease in HR was observed. In one of them, interval between two consecutive beats increased up to 1.7 seconds during the discharge. New onset of supraventricular premature beats was observed after discharge in 1 patient. Results of MTWA-1, MTWA-2, and MTWA-3 tests were positive in one of the subjects, each time in a different case.Standard EMD exposure can be associated with a nonuniform reaction of HR and followed by heart rhythm disturbances. New MTWA positivity can reflect either the effect of EMD exposure or a potential false positivity of MTWA assessments.
Parametric Interactions between Alfven waves in LaPD
NASA Astrophysics Data System (ADS)
Brugman, B.; Carter, T. A.; Cowley, S. C.; Pribyl, P.; Lybarger, W.
2004-11-01
The physics governing interactions between large amplitude Alfvén waves, which are relevant to plasmas in space as well as the laboratory, is at present not well understood. A major class of such interactions which are believed to occur in compressible plasmas is referred to as parametric decay. We will present the results of a series of experiments involving the interactions of large amplitude LHP Alfvén wave conducted on the Large Plasma Device (LaPD); where β ≪ 1, n ˜ 10^12 frac1cm^3 and B0 in (200,2500) G. These experiments show strong signs of one form of parametric decay, known as the Modulational Instability, which represents the interaction of two Alfvén waves and a low frequency density perturbation. This interaction is believed to occur in plasmas with β < 1 as well as β > 1, over a broad range of wavevector space, and for RHP as well as LHP Alfvén waves - distinguishing it from the Beat and Decay instabilities. Details of this interaction, in particular the structure of the incident waves as well as that of their byproducts, will be shown in physical as well as wavevector space. The generation of large amplitude waves using both an Alfvén wave MASER and high current loop antennas will also be illustrated. Lastly theoretical descriptions of parametric decay will be presented and compared to observations. Future work will also include comparisons of experimental results with applicable simulations, such as GS2. Work supported by DOE grant number DE-FG03-02ER54688
Annotated Bibliography of USAARL Technical and Letter Reports. Volume 1. June 1963 - September 1987
1991-05-01
continuous information concerning the duration, ampli- tude and slow-phase velocity of each nystagmic beat during experiments involving the vestibular...one lead of EKG for a full work day. Mean heart rates were tabulated from the record during: Administrative work (87.2 beats per minute), automobile...driving (85.5 beats per minute), eating (90.1 beats per minute), and flying (92.0 beats per minute). Using Tukey’s multiple comparison of means
Nonlinear Whistler Wave Physics in the Radiation Belts
NASA Astrophysics Data System (ADS)
Crabtree, Chris
2016-10-01
Wave particle interactions between electrons and whistler waves are a dominant mechanism for controlling the dynamics of energetic electrons in the radiation belts. They are responsible for loss, via pitch-angle scattering of electrons into the loss cone, and energization to millions of electron volts. It has previously been theorized that large amplitude waves on the whistler branch may scatter their wave-vector nonlinearly via nonlinear Landau damping leading to important consequences for the global distribution of whistler wave energy density and hence the energetic electrons. It can dramatically reduce the lifetime of energetic electrons in the radiation belts by increasing the pitch angle scattering rate. The fundamental building block of this theory has now been confirmed through laboratory experiments. Here we report on in situ observations of wave electro-magnetic fields from the EMFISIS instrument on board NASA's Van Allen Probes that show the signatures of nonlinear scattering of whistler waves in the inner radiation belts. In the outer radiation belts, whistler mode chorus is believed to be responsible for the energization of electrons from 10s of Kev to MeV energies. Chorus is characterized by bursty large amplitude whistler mode waves with frequencies that change as a function of time on timescales corresponding to their growth. Theories explaining the chirping have been developed for decades based on electron trapping dynamics in a coherent wave. New high time resolution wave data from the Van Allen probes and advanced spectral techniques are revealing that the wave dynamics is highly structured, with sub-elements consisting of multiple chirping waves with discrete frequency hops between sub-elements. Laboratory experiments with energetic electron beams are currently reproducing the complex frequency vs time dynamics of whistler waves and in addition revealing signatures of wave-wave and beat-wave nonlinear wave-particle interactions. These new data suggest that these weak turbulence processes may be playing a role in saturating the nonlinear instability.
Mercury Beating Heart: Modifications to the Classical Demonstration
ERIC Educational Resources Information Center
Najdoski, Metodija; Mirceski, Valentin; Petrusevski, Vladimir M.; Demiri, Sani
2007-01-01
The mercury beating heart (MBH) is a commonly performed experiment, which is based on varying oxidizing agents and substituting other metals for iron. Various modified versions of the classical demonstration of the experiment are presented.
NASA Astrophysics Data System (ADS)
Ermishkin, V. V.; Kolesnikov, V. A.; Lukoshkova, E. V.; Sonina, R. S.
2013-04-01
The impedance cardiography (ICG) is widely used for beat-to-beat noninvasive evaluation of the left ventricular stroke volume and contractility. It implies the correct determination of the ejection start and end points and the amplitudes of certain peaks in the differentiated impedance cardiogram. An accurate identification of ejection onset by ICG is often problematic, especially in the cardiologic patients, due to peculiar waveforms. Using a simple theoretical model, we tested the hypothesis that two major processes are responsible for the formation of impedance systolic wave: (1) the changes in the heart geometry and surrounding vessels produced by ventricular contraction, which occur during the isovolumic phase and precede ejection, and (2) expansion of aorta and adjacent arteries during the ejection phase. The former process initiates the preejection wave WpE and the latter triggers the ejection wave WEj. The model predicts a potential mechanism of generating the abnormal shapes of dZ/dt due to the presence of preejection waves and explains the related errors in ICG time and amplitude parameters. An appropriate decomposition method is a promising way to avoid the masking effects of these waves and a further step to correct determination of the onset of ejection and the corresponding peak amplitudes from 'pathologically shaped' ICG signals.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.
Di Rienzo, Marco; Vaini, Emanuele; Castiglioni, Paolo; Meriggi, Paolo; Rizzo, Francesco
2013-01-01
Seismocardiogram (SCG) is the measure of the minute vibrations produced by the beating heart. We previously demonstrated that SCG, ECG and respiration could be recorded over the 24 h during spontaneous behavior by a smart garment, the MagIC-SCG system. In the present case study we explored the feasibility of a beat-to-beat estimation of two indices of heart contractility, the Left Ventricular Ejection Time (LVET) and the electromechanical systole (QS2) from SCG and ECG recordings obtained by the MagIC-SCG device in one subject. We considered data collected during outdoor spontaneous behavior (while sitting in the metro and in the office) and in a laboratory setting (in supine and sitting posture, and during recovery after 100 W and 140 W cycling). LVET was estimated from SCG as the time interval between the opening and closure of the aortic valve, QS2 as the time interval between the Q wave of the ECG and the closure of the aortic valve. In every condition, LVET and QS2 could be estimated on a beat-to-beat basis from the SCG collected by the smart garment. LVET and QS2 are characterized by important beat-to-beat fluctuations, with standard deviations in the same order of magnitude of RR Interval. In all settings, spectral profiles are different for LVET, QS2 and RR Interval. This suggests that the biological mechanisms impinging on the heart exert a differentiated influence on the variability of each of these three indices.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.
Stochastic Ion Heating by the Lower-Hybrid Waves
NASA Technical Reports Server (NTRS)
Khazanov, G.; Tel'nikhin, A.; Krotov, A.
2011-01-01
The resonance lower-hybrid wave-ion interaction is described by a group (differentiable map) of transformations of phase space of the system. All solutions to the map belong to a strange attractor, and chaotic motion of the attractor manifests itself in a number of macroscopic effects, such as the energy spectrum and particle heating. The applicability of the model to the problem of ion heating by waves at the front of collisionless shock as well as ion acceleration by a spectrum of waves is discussed. Keywords: plasma; ion-cyclotron heating; shocks; beat-wave accelerator.
NASA Astrophysics Data System (ADS)
Dombrowski, M. P.; Labelle, J. W.; Kletzing, C.; Bounds, S. R.; Kaeppler, S. R.
2013-12-01
Bursty Langmuir waves have been interpreted as the result of the superposition of multiple Langmuir normal-mode waves, with the resultant modulation being the beat pattern between waves with e.g. 10 kHz frequency differences. The normal-mode waves could be generated either through wave-wave interactions with VLF waves, or through independent linear processes. The CHARM II sounding rocket was launched into a substorm at 9:49 UT on 15 February 2010, from the Poker Flat Research Range in Alaska. The primary instruments included the Dartmouth High-Frequency Experiment (HFE), a receiver system which effectively yields continuous (100% duty cycle) E-field waveform measurements up to 5 MHz, as well as a number of charged particle detectors, including a wave-particle correlator. The payload also included a magnetometer and several low-frequency wave instruments. CHARM II encountered several regions of strong Langmuir wave activity throughout its 15-minute flight, including several hundred discrete Langmuir-wave bursts. We show results of a statistical analysis of CHARM II data for the entire flight, comparing HFE data with the other payload instruments, specifically looking at timings and correlations between bursty Langmuir waves, Alfvén and whistler-mode waves, and electrons precipitating parallel to the magnetic field. Following a similar analysis on TRICE dayside sounding rocket data, we also calculate the fraction of correlated waves with VLF waves at appropriate frequencies to support the wave-wave interaction bursty Langmuir wave generation mechanism, and compare to results from CHARM II nightside data.
Engineering studies of vectorcardiographs in blood pressure measuring systems
NASA Technical Reports Server (NTRS)
Mark, R. G.
1975-01-01
The following projects involving cardiovascular instrumentation were conducted: (1) the development and fabrication of a three-dimensional display measurement system for vectorcardiograms, (2) the development and fabrication of a cardiovascular monitoring system to noninvasively monitor beat-by-beat the blood pressure and heart rate using aortic pulse wave velocity, (3) the development of software for an interactive system to analyze systolic time interval data, and (4) the development of microprocessor-based physiologic instrumentation, focussing initially on EKG rhythm analysis. Brief descriptions of these projects were given.
A quantitative electroencephalographic study of meditation and binaural beat entrainment.
Lavallee, Christina F; Koren, Stanley A; Persinger, Michael A
2011-04-01
The study objective was to determine the quantitative electroencephalographic correlates of meditation, as well as the effects of hindering (15 Hz) and facilitative (7 Hz) binaural beats on the meditative process. The study was a mixed design, with experience of the subject as the primary between-subject measure and power of the six classic frequency bands (δ, θ, low α, high α, β, γ), neocortical lobe (frontal, temporal, parietal, occipital), hemisphere (left, right), and condition (meditation only, meditation with 7-Hz beats, meditation with 15-Hz beats) as the within-subject measures. The study was conducted at Laurentian University in Sudbury, Ontario, Canada. The subjects comprised novice (mean of 8 months experience) and experienced (mean of 18 years experience) meditators recruited from local meditation groups. Experimental manipulation included application of hindering and facilitative binaural beats to the meditative process. Experienced meditators displayed increased left temporal lobe δ power when the facilitative binaural beats were applied, whereas the effect was not observed for the novice subjects in this condition. When the hindering binaural beats were introduced, the novice subjects consistently displayed more γ power than the experienced subjects over the course of their meditation, relative to baseline. Based on the results of this study, novice meditators were not able to maintain certain levels of θ power in the occipital regions when hindering binaural beats were presented, whereas when the facilitative binaural beats were presented, the experienced meditators displayed increased θ power in the left temporal lobe. These results suggest that the experienced meditators have developed techniques over the course of their meditation practice to counter hindering environmental stimuli, whereas the novice meditators have not yet developed those techniques.
NASA Astrophysics Data System (ADS)
Capstick, J. W.
2013-01-01
1. The nature of sound; 2. Elasticity and vibrations; 3. Transverse waves; 4. Longitudinal waves; 5. Velocity of longitudinal waves; 6. Reflection and refraction. Doppler's principle; 7. Interference. Beats. Combination tones; 8. Resonance and forced vibrations; 9. Quality of musical notes; 10. Organ pipes; 11. Rods. Plates. Bells; 12. Acoustical measurements; 13. The phonograph, microphone and telephone; 14. Consonance; 15. Definition of intervals. Scales. Temperament; 16. Musical instruments; 17. Application of acoustical principles to military purposes; Questions; Answers to questions; Index.
Tagging the neuronal entrainment to beat and meter.
Nozaradan, Sylvie; Peretz, Isabelle; Missal, Marcus; Mouraux, André
2011-07-13
Feeling the beat and meter is fundamental to the experience of music. However, how these periodicities are represented in the brain remains largely unknown. Here, we test whether this function emerges from the entrainment of neurons resonating to the beat and meter. We recorded the electroencephalogram while participants listened to a musical beat and imagined a binary or a ternary meter on this beat (i.e., a march or a waltz). We found that the beat elicits a sustained periodic EEG response tuned to the beat frequency. Most importantly, we found that meter imagery elicits an additional frequency tuned to the corresponding metric interpretation of this beat. These results provide compelling evidence that neural entrainment to beat and meter can be captured directly in the electroencephalogram. More generally, our results suggest that music constitutes a unique context to explore entrainment phenomena in dynamic cognitive processing at the level of neural networks.
Cartier, R; Brann, S; Dagenais, F; Martineau, R; Couturier, A
2000-02-01
We sought to report our recent experience with off-pump coronary artery revascularization in multivessel disease. Between October 1996 and December 1998, 300 off-pump beating heart operations were performed at the Montreal Heart Institute by a single surgeon, representing 94% of all procedures undertaken during this same time frame (97% for 1998). This cohort of patients was compared with 1870 patients operated on with cardiopulmonary bypass from 1995 to 1996. Mean age, sex distribution, and preoperative risk factors were comparable for the two groups. On average, 2.92 +/- 0.8 and 2.84 +/- 0.6 grafts per patient were completed in the beating heart and cardiopulmonary bypass groups, respectively. A majority of patients (70%) had either a triple or quadruple bypass. Coronary anastomoses were achieved with myocardial mechanical stabilization and heart "verticalization." Ischemic time was shorter in the beating heart group (29.8 +/- 0.9 vs 45 +/- 0.4 minutes, P <.05). Similarly, the need for transfusion was significantly less in the beating heart group (beating heart operations, 34%; cardiopulmonary bypass, 66%; P <.005). Reduced use of postoperative intra-aortic counterpulsation, as well as a lower rise in creatine kinase MB isoenzyme, was observed in the beating heart group. Operative mortality rates (beating heart operations, 1. 3%; cardiopulmonary bypass, 2%) and perioperative myocardial infarction (beating heart operations, 3.6%; cardiopulmonary bypass, 4.2%) were comparable for the two groups. In a majority of patients, off-pump complete coronary artery revascularization is an acceptable alternative to conventional operations, yielding good results given progressive experience, rigorous technique, and adequate coronary artery stabilization.
Pan, Yunping; Zhang, Fangfang; Liu, Ru; Jing, Yan; Shen, Jihong; Li, Zhongjian; Zhu, Huaijie
2014-06-01
To explore the characteristics of RR-Lorenz plot in persistent atrial fibrillation (AF) patients complicating with escape beats and rhythm though ambulatory electrocardiogram. The 24-hour ambulatory electrocardiogram of 291 persistent AF patients in second affiliated hospital of Zhengzhou university from July 2005 to April 2013 were retrospectively analyzed and the RR interval and the QRS wave were measured. Patients were divided into two groups according to the distribution of the RR-Lorenz point [AF without escape beats and rhythm group (Group A, n = 259) and AF with escape beats and rhythm group (Group B, n = 32)]. The characteristics of RR-Lorenz plot between the two groups were compared. (1) Fan-shaped RR-Lorenz plots were evidenced in Group A. (2)In Group B, 30 cases showed fan-shaped with L-shaped and a short dense rods along 45° line. The proportion of escape beats and rhythm was 0.28% (275/98 369) -14.06% (11 263/80 112) . The other 2 cases in group B showed no typical RR-Lorenz plots features. RR-Lorenz plot could help to quickly diagnose persistent AF complicating with escape beats and rhythm according to the typical RR-Lorenz plot characteristics in 24-hour ambulatory electrocardiogram.
Xiao, Hanguang; Tan, Isabella; Butlin, Mark; Li, Decai; Avolio, Alberto P
2017-06-01
Experimental investigations have established that the stiffness of large arteries has a dependency on acute heart rate (HR) changes. However, the possible underlying mechanisms inherent in this HR dependency have not been well established. This study aimed to explore a plausible viscoelastic mechanism by which HR exerts an influence on arterial stiffness. A multisegment transmission line model of the human arterial tree incorporating fractional viscoelastic components in each segment was used to investigate the effect of varying fractional order parameter (α) of viscoelasticity on the dependence of aortic arch to femoral artery pulse wave velocity (afPWV) on HR. HR was varied from 60 to 100 beats/min at a fixed mean flow of 100 ml/s. PWV was calculated by intersecting tangent method (afPWV Tan ) and by phase velocity from the transfer function (afPWV TF ) in the time and frequency domain, respectively. PWV was significantly and positively associated with HR for α ≥ 0.6; for α = 0.6, 0.8, and 1, HR-dependent changes in afPWV Tan were 0.01 ± 0.02, 0.07 ± 0.04, and 0.22 ± 0.09 m/s per 5 beats/min; HR-dependent changes in afPWV TF were 0.02 ± 0.01, 0.12 ± 0.00, and 0.34 ± 0.01 m/s per 5 beats/min, respectively. This crosses the range of previous physiological studies where the dependence of PWV on HR was found to be between 0.08 and 0.10 m/s per 5 beats/min. Therefore, viscoelasticity of the arterial wall could contribute to mechanisms through which large artery stiffness changes with changing HR. Physiological studies are required to confirm this mechanism. NEW & NOTEWORTHY This study used a transmission line model to elucidate the role of arterial viscoelasticity in the dependency of pulse wave velocity on heart rate. The model uses fractional viscoelasticity concepts, which provided novel insights into arterial hemodynamics. This study also provides a means of assessing the clinical manifestation of the association of pulse wave velocity and heart rate. Copyright © 2017 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Dugan, Mark Allen
1990-08-01
The theoretical basis for new signal transients and spectral features generated in field correlated four wave mixing (4WM) spectroscopies is developed. Special attention is given to those signal responses that are sensitive to phase/amplitude correlation among the input driving fields and not simply their intensity correlation. Thus, the cases of incoherent broadband excitation and of coherent short pulsed excitation will be discussed and compared. Applications to the coherent Raman spectroscopies, both electronically nonresonant and fully resonant, are analyzed. Novel interferometric oscillatory behavior is exposed in terms of field-matter detuning beats and matter-matter bi-level and tri-level quantum beats. In addition new detuning resonances are found that have sub-material linewidths and lock onto the mode frequency of the driven chromophore. These spectral features are a member of a class of bichromophore resonant lineshapes arising from nonlinear mixing with correlated driving fields. The origin of such bichromophore resonances can be based on a coupling between two field-matter superposition states driven by correlated fields on separate chromophores. Analytic results are presented and modelled to anticipate the experimental results presented in a following chapter. The onset of resolvable homogeneous electronic memory is reported in room temperature solutions of dye molecules. A narrowing of the homogeneous linewidths with increasing concentration of these dye solutions is observed in sub-picosecond photon echo experiments. This effect is attributed to aggregation which results in a delocalization of the electronic states over several molecules. Ultra -fast spectral diffusion in these dye aggregates is observed in stimulated photon echo measurements. Aggregate bands, seen in the linear absorption spectrum only at high concentrations, can be probed in more dilute solutions with nonlinear four wave mixing.
Rolling rhythms in front crawl swimming with six-beat kick.
Sanders, Ross H; Psycharakis, Stelios G
2009-02-09
The purpose of this study was to establish the rhythm characteristics of skilled front crawl swimmers using a six-beat kick. These included the amplitudes of the first three Fourier harmonics (H1, H2, H3) and their percent contributions to power contained in the angular displacement signals of the shoulders, hips, knees, and ankles with respect to the longitudinal axis in line with the swimming direction. Three-dimensional video data of seven national/international level swimmers were collected during simulated 200m front crawl races in which swimmers maintained six-beat kicking patterns. Swimmers differed in all variables but had small variability across the four 50m laps. Modest changes occurred during the 200m, with the exception of shoulder roll, which remained constant and was represented almost entirely by a single sinusoid (H1). Changes across laps reached significance for swimming speed, stroke rate, hip roll, and H3 wave velocity between the knee and ankle. A H3 body wave of moderate and increasing velocity travelled caudally from hip to ankle. In the light of existing knowledge of aquatic locomotion this was compatible with the goal of generating propulsion in an efficient manner.
Smith, Eric R; Jonas, David M
2011-04-28
The pump-probe polarization anisotropy is computed for molecules with a nondegenerate ground state, two degenerate or nearly degenerate excited states with perpendicular transition dipoles, and no resonant excited-state absorption. Including finite pulse effects, the initial polarization anisotropy at zero pump-probe delay is predicted to be r(0) = 3/10 with coherent excitation. During pulse overlap, it is shown that the four-wave mixing classification of signal pathways as ground or excited state is not useful for pump-probe signals. Therefore, a reclassification useful for pump-probe experiments is proposed, and the coherent anisotropy is discussed in terms of a more general transition dipole and molecular axis alignment instead of experiment-dependent ground- versus excited-state pathways. Although coherent excitation enhances alignment of the transition dipole, the molecular axes are less aligned than for a single dipole transition, lowering the initial anisotropy. As the splitting between excited states increases beyond the laser bandwidth and absorption line width, the initial anisotropy increases from 3/10 to 4/10. Asymmetric vibrational coordinates that lift the degeneracy control the electronic energy gap and off-diagonal coupling between electronic states. These vibrations dephase coherence and equilibrate the populations of the (nearly) degenerate states, causing the anisotropy to decay (possibly with oscillations) to 1/10. Small amounts of asymmetric inhomogeneity (2 cm(-1)) cause rapid (130 fs) suppression of both vibrational and electronic anisotropy beats on the excited state, but not vibrational beats on the ground electronic state. Recent measurements of conical intersection dynamics in a silicon napthalocyanine revealed anisotropic quantum beats that had to be assigned to asymmetric vibrations on the ground electronic state only [Farrow, D. A.; J. Chem. Phys. 2008, 128, 144510]. Small environmental asymmetries likely explain the observed absence of excited-state asymmetric vibrations in those experiments.
Footprints of storms on the sea: A view from spaceborne synthetic aperture radar
NASA Technical Reports Server (NTRS)
Atlas, David
1994-01-01
Synthetic aperture radar (SAR) on board Seasat observed images of stormlike echoes on the sea in 1978. The core of these images is usually an echo-free hole which is attributed to the damping of the short (30-cm) radar detectable gravity waves by the intense rain in the storm core. Although 'the beating down of waves by rain' is consistent with observations by seafarers and with the first scientific explanation of the phenomenon by Reynolds (1875), neither theory nor experiment has provided definitive support. One experiment appears to provide the key; it shows that the kenetic energy of the rain produces sufficient turbulence in a thin fresh water layer to damp 30-cm waves in 10-20 s, thus producing the echo-free hole. A sequence of positive feedbacks then serves to damp the longer waves. The angular dependence of the sea surface echo cross sections seen by Seasat SAR outside the echo-free hole indicates winds diverging from the downdraft induced by the intense rain core. The wind-generated waves and associated echoes extend out to a sharply defined gust front. The sea surface footprint thus mimics the features of a storm microburst. The variations in surface radar cross section due to a combination of rain and wind effects impacts spaceborne measurements of surface winds by scatterometry and rainfall measurements by radar. Portions of this synthesis remain speculative but serve as hypotheses for further research.
Arrhythmia during extracorporeal shock wave lithotripsy.
Zeng, Z R; Lindstedt, E; Roijer, A; Olsson, S B
1993-01-01
A prospective study of arrhythmia during extracorporeal shock wave lithotripsy (ESWL) was performed in 50 patients, using an EDAP LT01 piezoelectric lithotriptor. The 12-lead standard ECG was recorded continuously for 10 min before and during treatment. One or more atrial and/or ventricular ectopic beats occurred during ESWL in 15 cases (30%). The occurrence of arrhythmia was similar during right-sided and left-sided treatment. One patient developed multifocal ventricular premature beats and ventricular bigeminy; another had cardiac arrest for 13.5 s. It was found that various irregularities of the heart rhythm can be caused even by treatment with a lithotriptor using piezoelectric energy to create the shock wave. No evidence was found, however, that the shock wave itself rather than vagal activation and the action of sedo-analgesia was the cause of the arrhythmia. For patients with severe underlying heart disease and a history of complex arrhythmia, we suggest that the ECG be monitored during treatment. In other cases, we have found continuous monitoring of oxygen saturation and pulse rate with a pulse oximeter to be perfectly reliable for raising the alarm when depression of respiration and vaso-vagal reactions occur.
Metachronal Motion of Artificial Magnetic Cilia
NASA Astrophysics Data System (ADS)
Hanasoge, Srinivas; Hesketh, Peter; Alexeev, Alexander
2017-11-01
Most microorganisms use asymmetrically oscillating hair like cilia on their surface to achieve fluid transport. These cilia are often seen to beat in a metachronal fashion with a constant phase difference with the neighbors which generates a travelling wave. Although the origin of metachronal waves in such cilia is not well understood, mimicking such behavior in synthetic systems could prove useful in achieving similar advantages. In this work, we demonstrate metachronal waves in synthetic magnetic ciliary systems. The soft magnetic cilia are forced by a uniform rotating magnetic field. The cilia bend as the field rotates and tend to align along the direction of field to minimize the potential energy. Longer cilia bend to a larger degree, while the shorter cilia show less bending. This difference in the bending of cilia based on their length leads to a phase difference in their oscillation cycle. We exploit this phase differences to metachronally oscillate the synthetic cilia. We fabricate an array consisting of cilia with increasing lengths, in which the cilia beat with a constant phase difference with the neighboring cilia, producing a travelling wave. Such behavior could potentially be useful in enhanced fluid and particle transport as seen in natural systems. USDA.
Ginger: Measuring Gravitomagnetic Effects by Means of Light
NASA Astrophysics Data System (ADS)
Tartaglia, Angelo
2015-01-01
GINGER is a proposal for a new experiment aimed to the detection of the gravito-magnetic Lense-Thirring effect at the surface of the Earth. A three-dimensional set of ring lasers will be mounted on a rigid "monument". In a ring laser a light beam traveling counterclockwise is superposed to another beam traveling in the opposite sense. The anisotropy in the propagation leads to standing waves with slightly different frequencies in the two directions; the resulting beat frequency is proportional to the absolute rotation rate in space, including the gravito-magnetic drag. The experiment is planned to be built in the Gran Sasso National Laboratories in Italy and is based on an international collaboration among four Italian groups, the Technische Universität München and the University of Canterbury in Christchurch (NZ).
Breska, Assaf; Deouell, Leon Y
2016-07-06
Environmental rhythms potently drive predictive resource allocation in time, typically leading to perceptual and motor benefits for on-beat, relative to off-beat, times, even if the rhythmic stream is not intentionally used. In two human EEG experiments, we investigated the behavioral and electrophysiological expressions of using rhythms to direct resources away from on-beat times. This allowed us to distinguish goal-directed attention from the automatic capture of attention by rhythms. The following three conditions were compared: (1) a rhythmic stream with targets appearing frequently at a fixed off-beat position; (2) a rhythmic stream with targets appearing frequently at on-beat times; and (3) a nonrhythmic stream with matched target intervals. Shifting resources away from on-beat times was expressed in the slowing of responses to on-beat targets, but not in the facilitation of off-beat targets. The shifting of resources was accompanied by anticipatory adjustment of the contingent negative variation (CNV) buildup toward the expected off-beat time. In the second experiment, off-beat times were jittered, resulting in a similar CNV adjustment and also in preparatory amplitude reduction of beta-band activity. Thus, the CNV and beta activity track the relevance of time points and not the rhythm, given sufficient incentive. Furthermore, the effects of task relevance (appearing in a task-relevant vs irrelevant time) and rhythm (appearing on beat vs off beat) had additive behavioral effects and also dissociable neural manifestations in target-evoked activity: rhythm affected the target response as early as the P1 component, while relevance affected only the later N2 and P3. Thus, these two factors operate by distinct mechanisms. Rhythmic streams are widespread in our environment, and are typically conceptualized as automatic, bottom-up resource attractors to on-beat times-preparatory neural activity peaks at rhythm-on-beat times and behavioral benefits are seen to on-beat compared with off-beat targets. We show that this behavioral benefit is reversed when targets are more frequent at off-beat compared with on-beat times, and that preparatory neural activity, previously thought to be driven by the rhythm to on-beat times, is adjusted toward off-beat times. Furthermore, the effect of this relevance-based shifting on target-evoked brain activity was dissociable from the automatic effect of rhythms. Thus, rhythms can act as cues for flexible resource allocation according to the goal relevance of each time point, instead of being obligatory resource attractors. Copyright © 2016 the authors 0270-6474/16/367154-13$15.00/0.
NASA Astrophysics Data System (ADS)
Dey, Supravat; Massiera, Gladys; Pitard, Estelle
2018-01-01
Cilia are elastic hairlike protuberances of the cell membrane found in various unicellular organisms and in several tissues of most living organisms. In some tissues such as the airway tissues of the lung, the coordinated beating of cilia induces a fluid flow of crucial importance as it allows the continuous cleaning of our bronchia, known as mucociliary clearance. While most of the models addressing the question of collective dynamics and metachronal wave consider homogeneous carpets of cilia, experimental observations rather show that cilia clusters are heterogeneously distributed over the tissue surface. The purpose of this paper is to investigate the role of spatial heterogeneity on the coherent beating of cilia using a very simple one-dimensional model for cilia known as the rower model. We systematically study systems consisting of a few rowers to hundreds of rowers and we investigate the conditions for the emergence of collective beating. When considering a small number of rowers, a phase drift occurs, hence, a bifurcation in beating frequency is observed as the distance between rower clusters is changed. In the case of many rowers, a distribution of frequencies is observed. We found in particular the pattern of the patchy structure that shows the best robustness in collective beating behavior, as the density of cilia is varied over a wide range.
On readout of vibrational qubits using quantum beats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shyshlov, Dmytro; Babikov, Dmitri, E-mail: Dmitri.Babikov@mu.edu; Berrios, Eduardo
2014-12-14
Readout of the final states of qubits is a crucial step towards implementing quantum computation in experiment. Although not scalable to large numbers of qubits per molecule, computational studies show that molecular vibrations could provide a significant (factor 2–5 in the literature) increase in the number of qubits compared to two-level systems. In this theoretical work, we explore the process of readout from vibrational qubits in thiophosgene molecule, SCCl{sub 2}, using quantum beat oscillations. The quantum beats are measured by first exciting the superposition of the qubit-encoding vibrational states to the electronically excited readout state with variable time-delay pulses. Themore » resulting oscillation of population of the readout state is then detected as a function of time delay. In principle, fitting the quantum beat signal by an analytical expression should allow extracting the values of probability amplitudes and the relative phases of the vibrational qubit states. However, we found that if this procedure is implemented using the standard analytic expression for quantum beats, a non-negligible phase error is obtained. We discuss the origin and properties of this phase error, and propose a new analytical expression to correct the phase error. The corrected expression fits the quantum beat signal very accurately, which may permit reading out the final state of vibrational qubits in experiments by combining the analytic fitting expression with numerical modelling of the readout process. The new expression is also useful as a simple model for fitting any quantum beat experiments where more accurate phase information is desired.« less
Hydrodynamic synchronization of flagella on the surface of the colonial alga Volvox carteri
NASA Astrophysics Data System (ADS)
Brumley, Douglas; Polin, Marco; Goldstein, Raymond; Pedley, Timothy
2012-11-01
Whether on the surface of unicellular ciliates or in the respiratory epithelium, groups of eukaryotic cilia and flagella are capable of coordinating their beating over large scales. The mechanism responsible for the emergence of these metachronal waves is still unclear, mostly because finding an experimental system in which the beating filaments can be followed individually is challenging. We propose the multicellular green alga Volvox carteri as an ideal model system to study metachronal coordination, and report the existence of robust metachronal waves on its surface. Inspired by flagellar tip trajectories of Volvox somatic cells, we model a flagellum using a sphere of radius a elastically bound to a circular orbit of radius r0, perpendicular to a no-slip plane. This elastohydrodynamic model of weakly-coupled self-sustained oscillators can be recast in terms of interacting phase oscillators, offering an intuitive understanding of the mechanism driving the emergence of coordination. Our results confirm that elasticity is fundamental to guarantee fast and robust synchronization, and that sufficiently compliant trajectories lead to the emergence of metachronal waves in a manner essentially independent of boundary conditions.
Optical detection of symmetric and antisymmetric states in double quantum wells at room temperature
NASA Astrophysics Data System (ADS)
Marchewka, M.; Sheregii, E. M.; Tralle, I.; Marcelli, A.; Piccinini, M.; Cebulski, J.
2009-09-01
We studied the optical reflectivity of a specially grown double quantum well (DQW) structure characterized by a rectangular shape and a high electron density at room temperature. Assuming that the QWs depth is known, reflectivity spectra in the mid-IR range allow to carry out the precise measurements of the SAS-gap values (the energy gap between the symmetric and anti-symmetric states) and the absolute energies of both symmetric and antisymmetric electron states. The results of our experiments are in favor of the existence of the SAS splitting in the DQWs at room temperature. Here we have shown that the SAS gap increases proportionally to the subband quantum number and the optical electron transitions between symmetric and antisymmetric states belonging to different subbands are allowed. These results were used for interpretation of the beating effect in the Shubnikov-de Haas (SdH) oscillations at low temperatures (0.6 and 4.2 K). The approach to the calculation of the Landau-levels energies for DQW structures developed earlier [D. Ploch , Phys. Rev. B 79, 195434 (2009)] is used for the analysis and interpretation of the experimental data related to the beating effect. We also argue that in order to explain the beating effect in the SdH oscillations, one should introduce two different quasi-Fermi levels characterizing the two electron subsystems regarding symmetry properties of their wave functions, symmetric and antisymmetric ones. These states are not mixed neither by electron-electron interaction nor probably by electron-phonon interaction.
Maximum gravitational-wave energy emissible in magnetar flares
NASA Astrophysics Data System (ADS)
Corsi, Alessandra; Owen, Benjamin J.
2011-05-01
Recent searches of gravitational-wave data raise the question of what maximum gravitational-wave energies could be emitted during gamma-ray flares of highly magnetized neutron stars (magnetars). The highest energies (˜1049erg) predicted so far come from a model [K. Ioka, Mon. Not. R. Astron. Soc.MNRAA40035-8711 327, 639 (2001), http://adsabs.harvard.edu/abs/2001MNRAS.327..639I] in which the internal magnetic field of a magnetar experiences a global reconfiguration, changing the hydromagnetic equilibrium structure of the star and tapping the gravitational potential energy without changing the magnetic potential energy. The largest energies in this model assume very special conditions, including a large change in moment of inertia (which was observed in at most one flare), a very high internal magnetic field, and a very soft equation of state. Here we show that energies of 1048-1049erg are possible under more generic conditions by tapping the magnetic energy, and we note that similar energies may also be available through cracking of exotic solid cores. Current observational limits on gravitational waves from magnetar fundamental modes are just reaching these energies and will beat them in the era of advanced interferometers.
Matsunag, Daichi; Izumi, Shintaro; Okuno, Keisuke; Kawaguchi, Hiroshi; Yoshimoto, Masahiko
2015-01-01
This paper describes a non-contact and noise-tolerant heart beat monitoring system. The proposed system comprises a microwave Doppler sensor and range imagery using Microsoft Kinect™. The possible application of the proposed system is a driver health monitoring. We introduce the sensor fusion approach to minimize the heart beat detection error. The proposed algorithm can subtract a body motion artifact from Doppler sensor output using time-frequency analysis. The body motion artifact is a crucially important problem for biosignal monitoring using microwave Doppler sensor. The body motion speed is obtainable from range imagery, which has 5-mm resolution at 30-cm distance. Measurement results show that the success rate of the heart beat detection is improved about 75% on average when the Doppler wave is degraded by the body motion artifact.
Satir, Peter
1963-01-01
Upon excision into spring water, the lateral cilia of the gill of the freshwater mussel Elliptio complanatus (Solander) stop beating, but 0.04 M potassium ion can activate the gill so that these cilia again beat with metachronal rhythm. One per cent osmium tetroxide quickly pipetted onto a fully activated gill fixes the lateral cilia in a pattern that preserves the form and arrangement of the metachronal wave, and permits the cilia to be studied with the electron microscope in all stages of their beat cycle. Changes are seen in the fixed active preparation that are not present in the inactive control, i.e., in the packing of the cilia, the position of the axis of the ciliary cross-section, and the diameter of the ring of peripheral filaments. Analysis of these parameters may lead to new correlations between ciliary fine structure and function. PMID:14079494
Neural entrainment to the rhythmic structure of music.
Tierney, Adam; Kraus, Nina
2015-02-01
The neural resonance theory of musical meter explains musical beat tracking as the result of entrainment of neural oscillations to the beat frequency and its higher harmonics. This theory has gained empirical support from experiments using simple, abstract stimuli. However, to date there has been no empirical evidence for a role of neural entrainment in the perception of the beat of ecologically valid music. Here we presented participants with a single pop song with a superimposed bassoon sound. This stimulus was either lined up with the beat of the music or shifted away from the beat by 25% of the average interbeat interval. Both conditions elicited a neural response at the beat frequency. However, although the on-the-beat condition elicited a clear response at the first harmonic of the beat, this frequency was absent in the neural response to the off-the-beat condition. These results support a role for neural entrainment in tracking the metrical structure of real music and show that neural meter tracking can be disrupted by the presentation of contradictory rhythmic cues.
Spontaneous oscillation and fluid-structure interaction of cilia.
Han, Jihun; Peskin, Charles S
2018-04-24
The exact mechanism to orchestrate the action of hundreds of dynein motor proteins to generate wave-like ciliary beating remains puzzling and has fascinated many scientists. We present a 3D model of a cilium and the simulation of its beating in a fluid environment. The model cilium obeys a simple geometric constraint that arises naturally from the microscopic structure of a real cilium. This constraint allows us to determine the whole 3D structure at any instant in terms of the configuration of a single space curve. The tensions of active links, which model the dynein motor proteins, follow a postulated dynamical law, and together with the passive elasticity of microtubules, this dynamical law is responsible for the ciliary motions. In particular, our postulated tension dynamics lead to the instability of a symmetrical steady state, in which the cilium is straight and its active links are under equal tensions. The result of this instability is a stable, wave-like, limit cycle oscillation. We have also investigated the fluid-structure interaction of cilia using the immersed boundary (IB) method. In this setting, we see not only coordination within a single cilium but also, coordinated motion, in which multiple cilia in an array organize their beating to pump fluid, in particular by breaking phase synchronization.
Wu, Hau-Tieng; Lewis, Gregory F; Davila, Maria I; Daubechies, Ingrid; Porges, Stephen W
2016-10-17
With recent advances in sensor and computer technologies, the ability to monitor peripheral pulse activity is no longer limited to the laboratory and clinic. Now inexpensive sensors, which interface with smartphones or other computer-based devices, are expanding into the consumer market. When appropriate algorithms are applied, these new technologies enable ambulatory monitoring of dynamic physiological responses outside the clinic in a variety of applications including monitoring fatigue, health, workload, fitness, and rehabilitation. Several of these applications rely upon measures derived from peripheral pulse waves measured via contact or non-contact photoplethysmography (PPG). As technologies move from contact to non-contact PPG, there are new challenges. The technology necessary to estimate average heart rate over a few seconds from a noncontact PPG is available. However, a technology to precisely measure instantaneous heat rate (IHR) from non-contact sensors, on a beat-to-beat basis, is more challenging. The objective of this paper is to develop an algorithm with the ability to accurately monitor IHR from peripheral pulse waves, which provides an opportunity to measure the neural regulation of the heart from the beat-to-beat heart rate pattern (i.e., heart rate variability). The adaptive harmonic model is applied to model the contact or non-contact PPG signals, and a new methodology, the Synchrosqueezing Transform (SST), is applied to extract IHR. The body sway rhythm inherited in the non-contact PPG signal is modeled and handled by the notion of wave-shape function. The SST optimizes the extraction of IHR from the PPG signals and the technique functions well even during periods of poor signal to noise. We contrast the contact and non-contact indices of PPG derived heart rate with a criterion electrocardiogram (ECG). ECG and PPG signals were monitored in 21 healthy subjects performing tasks with different physical demands. The root mean square error of IHR estimated by SST is significantly better than commonly applied methods such as autoregressive (AR) method. In the walking situation, while AR method fails, SST still provides a reasonably good result. The SST processed PPG data provided an accurate estimate of the ECG derived IHR and consistently performed better than commonly applied methods such as autoregressive method.
Jump if you can't take the heat: three escape gaits of Paramecium swimming
NASA Astrophysics Data System (ADS)
Baroud, Charles N.; Hamel, Amandine; Fisch, Cathy; Combettes, Laurent; Dupuys-Williams, Pascale
2010-11-01
Paramecium is able to swim at velocities reaching several times its body size per second, by beating its thousands of cilia in an organized fashion. Here we show that Paramecium has in fact three distinct swimming gaits to escape from an aggression in the form of localized heating, depending on the magnitude of the aggression: For a weak agression, normal swimming is sufficient and produces a steady swimming velocity through cilia beating. As the heating amplitude is increased, a higher acceleration and faster swimming are achieved through synchronized beating of the cilia, which later give way to the usual metachronal waves. The synchronized beating yields high initial accelerations but requires the cell to coast through the synchrnized recovery. Finally, escape from a life-threatening agression is achieved by a "jumping" gait which does not rely on the cilia but is achieved from the explosive release of a rod-like organelles in the direction of the hot spot. Measurements through high-speed video explain the role of these rods in defending Paramecium. They also show that the zero-Reynolds number assumption is unverified in most cases.
Optimal ciliary beating patterns
NASA Astrophysics Data System (ADS)
Vilfan, Andrej; Osterman, Natan
2011-11-01
We introduce a measure for energetic efficiency of single or collective biological cilia. We define the efficiency of a single cilium as Q2 / P , where Q is the volume flow rate of the pumped fluid and P is the dissipated power. For ciliary arrays, we define it as (ρQ) 2 / (ρP) , with ρ denoting the surface density of cilia. We then numerically determine the optimal beating patterns according to this criterion. For a single cilium optimization leads to curly, somewhat counterintuitive patterns. But when looking at a densely ciliated surface, the optimal patterns become remarkably similar to what is observed in microorganisms like Paramecium. The optimal beating pattern then consists of a fast effective stroke and a slow sweeping recovery stroke. Metachronal waves lead to a significantly higher efficiency than synchronous beating. Efficiency also increases with an increasing density of cilia up to the point where crowding becomes a problem. We finally relate the pumping efficiency of cilia to the swimming efficiency of a spherical microorganism and show that the experimentally estimated efficiency of Paramecium is surprisingly close to the theoretically possible optimum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pietzsch, A.; Kennedy, B.; Sun, Y.-P.
2011-04-15
Resonant inelastic soft x-ray scattering (RIXS) spectra excited at the 1{sigma}{sub g}{yields}3{sigma}{sub u} resonance in gas-phase O{sub 2} show excitations due to the nuclear degrees of freedom with up to 35 well-resolved discrete vibronic states and a continuum due to the kinetic energy distribution of the separated atoms. The RIXS profile demonstrates spatial quantum beats caused by two interfering wave packets with different momenta as the atoms separate. Thomson scattering strongly affects both the spectral profile and the scattering anisotropy.
Inline CBET Model Including SRS Backscatter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bailey, David S.
2015-06-26
Cross-beam energy transfer (CBET) has been used as a tool on the National Ignition Facility (NIF) since the first energetics experiments in 2009 to control the energy deposition in ignition hohlraums and tune the implosion symmetry. As large amounts of power are transferred between laser beams at the entrance holes of NIF hohlraums, the presence of many overlapping beat waves can lead to stochastic ion heating in the regions where laser beams overlap [P. Michel et al., Phys. Rev. Lett. 109, 195004 (2012)]. Using the CBET gains derived in this paper, we show how to implement these equations in amore » ray-based laser source for a rad-hydro code.« less
Measuring Neural Entrainment to Beat and Meter in Infants: Effects of Music Background.
Cirelli, Laura K; Spinelli, Christina; Nozaradan, Sylvie; Trainor, Laurel J
2016-01-01
Caregivers often engage in musical interactions with their infants. For example, parents across cultures sing lullabies and playsongs to their infants from birth. Behavioral studies indicate that infants not only extract beat information, but also group these beats into metrical hierarchies by as early as 6 months of age. However, it is not known how this is accomplished in the infant brain. An EEG frequency-tagging approach has been used successfully with adults to measure neural entrainment to auditory rhythms. The current study is the first to use this technique with infants in order to investigate how infants' brains encode rhythms. Furthermore, we examine how infant and parent music background is associated with individual differences in rhythm encoding. In Experiment 1, EEG was recorded while 7-month-old infants listened to an ambiguous rhythmic pattern that could be perceived to be in two different meters. In Experiment 2, EEG was recorded while 15-month-old infants listened to a rhythmic pattern with an unambiguous meter. In both age groups, information about music background (parent music training, infant music classes, hours of music listening) was collected. Both age groups showed clear EEG responses frequency-locked to the rhythms, at frequencies corresponding to both beat and meter. For the younger infants (Experiment 1), the amplitudes at duple meter frequencies were selectively enhanced for infants enrolled in music classes compared to those who had not engaged in such classes. For the older infants (Experiment 2), amplitudes at beat and meter frequencies were larger for infants with musically-trained compared to musically-untrained parents. These results suggest that the frequency-tagging method is sensitive to individual differences in beat and meter processing in infancy and could be used to track developmental changes.
Measuring Neural Entrainment to Beat and Meter in Infants: Effects of Music Background
Cirelli, Laura K.; Spinelli, Christina; Nozaradan, Sylvie; Trainor, Laurel J.
2016-01-01
Caregivers often engage in musical interactions with their infants. For example, parents across cultures sing lullabies and playsongs to their infants from birth. Behavioral studies indicate that infants not only extract beat information, but also group these beats into metrical hierarchies by as early as 6 months of age. However, it is not known how this is accomplished in the infant brain. An EEG frequency-tagging approach has been used successfully with adults to measure neural entrainment to auditory rhythms. The current study is the first to use this technique with infants in order to investigate how infants' brains encode rhythms. Furthermore, we examine how infant and parent music background is associated with individual differences in rhythm encoding. In Experiment 1, EEG was recorded while 7-month-old infants listened to an ambiguous rhythmic pattern that could be perceived to be in two different meters. In Experiment 2, EEG was recorded while 15-month-old infants listened to a rhythmic pattern with an unambiguous meter. In both age groups, information about music background (parent music training, infant music classes, hours of music listening) was collected. Both age groups showed clear EEG responses frequency-locked to the rhythms, at frequencies corresponding to both beat and meter. For the younger infants (Experiment 1), the amplitudes at duple meter frequencies were selectively enhanced for infants enrolled in music classes compared to those who had not engaged in such classes. For the older infants (Experiment 2), amplitudes at beat and meter frequencies were larger for infants with musically-trained compared to musically-untrained parents. These results suggest that the frequency-tagging method is sensitive to individual differences in beat and meter processing in infancy and could be used to track developmental changes. PMID:27252619
Surface plasma wave assisted second harmonic generation of laser over a metal film
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chauhan, Santosh; Parashar, J., E-mail: j.p.parashar@gmail.com
2015-01-15
Second harmonic generation of laser mode converted surface plasma wave (SPW) over a corrugated metal film is studied. The laser, impinged on the metal film, under attenuated total reflection configuration, excites SPW over the metal–vacuum interface. The excited SPW extends over a much wider surface area than the laser spot cross-section. It exerts a second harmonic ponderomotive force on metal electrons, imparting them velocity that beats with the surface ripple to produce a nonlinear current, driving resonant second harmonic surface plasma wave.
The combined solar and tidal influence in climate
NASA Technical Reports Server (NTRS)
Bell, P. R.
1981-01-01
To provide an early warning indication of the CO2 warning signal, we are searching for periodic or projectable trends in climate. The strong 20.5 year oscillation in Eastern North American January temperature found by Mock and Hibler shows evidence of a beat between waves with periods of 22.36 (22.21 to 22.55) years and 18.64 (18.45 to 18.79) years with an opposition at about 1880. These are interpreted to be the 22.279 year solar Hale magnetic cycle and the 18.61 year lunar nodal tidal cycle. The lunar nodal cycle is known to produce changes in the sea surface temperature through increased mixing of the mixed layer of the ocean. This beat note is shown to be evident in the Western High Plains drought record of Mitchell, Stockton and Meko and to provide a better bit to the drought series, especially at the beat oppositions in 1880 and 1770.
Direct Visualization of Mechanical Beats by Means of an Oscillating Smartphone
NASA Astrophysics Data System (ADS)
Giménez, Marcos H.; Salinas, Isabel; Monsoriu, Juan A.; Castro-Palacio, Juan C.
2017-10-01
The resonance phenomenon is widely known in physics courses. Qualitatively speaking, resonance takes place in a driven oscillating system whenever the frequency approaches the natural frequency, resulting in maximal oscillatory amplitude. Very closely related to resonance is the phenomenon of mechanical beating, which occurs when the driving and natural frequencies of the system are slightly different. The frequency of the beat is just the difference of the natural and driving frequencies. Beats are very familiar in acoustic systems. There are several works in this journal on visualizing the beats in acoustic systems. For instance, the microphone and the speaker of two mobile devices were used in previous work to analyze the acoustic beats produced by two signals of close frequencies. The formation of beats can also be visualized in mechanical systems, such as a mass-spring system or a double-driven string. Here, the mechanical beats in a smartphone-spring system are directly visualized in a simple way. The frequency of the beats is measured by means of the acceleration sensor of a smartphone, which hangs from a spring attached to a mechanical driver. This laboratory experiment is suitable for both high school and first-year university physics courses.
Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.
Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi
2011-01-01
Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.
The role of attention and intention in synchronization to music: effects on gait.
Leow, Li-Ann; Waclawik, Kristina; Grahn, Jessica A
2018-01-01
Anecdotal accounts suggest that individuals spontaneously synchronize their movements to the 'beat' of background music, often without intending to, and perhaps even without attending to the music at all. However, the question of whether intention and attention are necessary to synchronize to the beat remains unclear. Here, we compared whether footsteps during overground walking were synchronized to the beat when young healthy adults were explicitly instructed to synchronize (intention to synchronize), and were not instructed to synchronize (no intention) (Experiment 1: intention). We also examined whether reducing participants' attention to the music affected synchronization, again when participants were explicitly instructed to synchronize, and when they were not (Experiment 2: attention/intention). Synchronization was much less frequent when no instructions to synchronize were given. Without explicit instructions to synchronize, there was no evidence of synchronization in 60% of the trials in Experiment 1, and 43% of the trials in Experiment 2. When instructed to synchronize, only 26% of trials in Experiment 1, and 14% of trials in Experiment 2 showed no evidence of synchronization. Because walking to music alters gait, we also examined how gait kinematics changed with or without instructions to synchronize, and attention to the music was required for synchronization to occur. Instructions to synchronize elicited slower, shorter, and more variable strides than walking in silence. Reducing attention to the music did not significantly affect synchronization of footsteps to the beat, but did elicit slower gait. Thus, during walking, intention, but not attention, appears to be necessary to synchronize footsteps to the beat, and synchronization elicits slower, shorter, and more variable strides, at least in young healthy adults.
NASA Astrophysics Data System (ADS)
Dasbiswas, K.; Majkut, S.; Discher, D. E.; Safran, Samuel A.
2015-01-01
Recent experiments show that both striation, an indication of the structural registry in muscle fibres, as well as the contractile strains produced by beating cardiac muscle cells can be optimized by substrate stiffness. Here we show theoretically how the substrate rigidity dependence of the registry data can be mapped onto that of the strain measurements. We express the elasticity-mediated structural registry as a phase-order parameter using a statistical physics approach that takes the noise and disorder inherent in biological systems into account. By assuming that structurally registered myofibrils also tend to beat in phase, we explain the observed dependence of both striation and strain measurements of cardiomyocytes on substrate stiffness in a unified manner. The agreement of our ideas with experiment suggests that the correlated beating of heart cells may be limited by the structural order of the myofibrils, which in turn is regulated by their elastic environment.
Godoy, Eduardo J.; Lozano, Miguel; Martínez-Mateu, Laura; Atienza, Felipe; Saiz, Javier; Sebastian, Rafael
2017-01-01
Non-invasive localization of continuous atrial ectopic beats remains a cornerstone for the treatment of atrial arrhythmias. The lack of accurate tools to guide electrophysiologists leads to an increase in the recurrence rate of ablation procedures. Existing approaches are based on the analysis of the P-waves main characteristics and the forward body surface potential maps (BSPMs) or on the inverse estimation of the electric activity of the heart from those BSPMs. These methods have not provided an efficient and systematic tool to localize ectopic triggers. In this work, we propose the use of machine learning techniques to spatially cluster and classify ectopic atrial foci into clearly differentiated atrial regions by using the body surface P-wave integral map (BSPiM) as a biomarker. Our simulated results show that ectopic foci with similar BSPiM naturally cluster into differentiated non-intersected atrial regions and that new patterns could be correctly classified with an accuracy of 97% when considering 2 clusters and 96% for 4 clusters. Our results also suggest that an increase in the number of clusters is feasible at the cost of decreasing accuracy. PMID:28704537
Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Fletcher, Richard R.; Abbott, Derek; Lovell, Nigel H.; Schuurmans, Dale
2015-01-01
Recent clinical studies show that the contour of the photoplethysmogram (PPG) wave contains valuable information for characterizing cardiovascular activity. However, analyzing the PPG wave contour is difficult; therefore, researchers have applied first or higher order derivatives to emphasize and conveniently quantify subtle changes in the filtered PPG contour. Our hypothesis is that analyzing the whole PPG recording rather than each PPG wave contour or on a beat-by-beat basis can detect heat-stressed subjects and that, consequently, we will be able to investigate the impact of global warming on human health. Here, we explore the most suitable derivative order for heat stress assessment based on the energy and entropy of the whole PPG recording. The results of our study indicate that the use of the entropy of the seventh derivative of the filtered PPG signal shows promising results in detecting heat stress using 20-second recordings, with an overall accuracy of 71.6%. Moreover, the combination of the entropy of the seventh derivative of the filtered PPG signal with the root mean square of successive differences, or RMSSD (a traditional heart rate variability index of heat stress), improved the detection of heat stress to 88.9% accuracy. PMID:26473907
Minkkinen, Mikko; Nieminen, Tuomo; Verrier, Richard L; Leino, Johanna; Lehtimäki, Terho; Viik, Jari; Lehtinen, Rami; Nikus, Kjell; Kööbi, Tiit; Turjanmaa, Väinö; Kähönen, Mika
2015-09-01
Exercise capacity, heart rate recovery and T-wave alternans are independent predictors of cardiovascular mortality. We tested whether these parameters contain supplementary prognostic information. A total of 3609 consecutive patients (2157 men) referred for a routine, clinically indicated bicycle exercise test were enrolled in the Finnish Cardiovascular Study (FINCAVAS). Exercise capacity was measured in metabolic equivalents, heart rate recovery as the decrease in heart rate from maximum to one minute post-exercise, and T-wave alternans by time-domain Modified Moving Average method. During 57-month median follow-up (interquartile range 35-78 months), 96 patients died of cardiovascular causes (primary endpoint) and 233 from any cause. All three parameters were independent predictors of cardiovascular mortality when analysed as continuous variables. Adding metabolic equivalents (p < 0.001), heart rate recovery (p = 0.002) or T-wave alternans (p = 0.01) to the linear model improved its predictive power for cardiovascular mortality. The combination of low exercise capacity (<6 metabolic equivalents), reduced heart rate recovery (≤12 beats/min) and elevated T-wave alternans (≥60 μV) yielded the highest hazard ratio for cardiovascular mortality of 16.5 (95% confidence interval 4.0-67.7, p < 0.001). Harrell's C index was 0.719 (confidence interval 0.665-0.772) for cardiovascular mortality with previously defined cutpoints (<8 units for metabolic equivalents, ≤18 beats/min for heart rate recovery and ≥60 μV for T-wave alternans). The prognostic capacity of the clinical exercise test is enhanced by combined analysis of exercise capacity, heart rate recovery and T-wave alternans. © The European Society of Cardiology 2014.
Johnson, Linda S B; Persson, Anders P; Wollmer, Per; Juul-Möller, Steen; Juhlin, Tord; Engström, Gunnar
2018-02-13
Atrial fibrillation (AF) is defined as an irregular supraventricular tachycardia (SVT) without p waves, with duration >30 seconds. Whether AF characteristics during short SVT episodes predict AF and stroke is not known. The purpose of this study was to determine whether irregularity and lack of p waves, alone or in combination, during short SVT episodes increase the risk of incident AF and ischemic stroke. The population-based Malmö Diet and Cancer study includes 24-hour ECG screening of 377 AF-free individuals (mean age 64.5 years; 43% men) who were prospectively followed for >13 years. There were 65 AF events and 25 ischemic stroke events during follow-up. Subjects with an SVT episode ≥5 beats were identified, and the longest SVT episode was assessed for irregularity and lack of p waves. The association between SVT classification and AF and stroke was assessed using multivariable adjusted Cox regression. The incidence of AF increased with increasing abnormality of the SVTs. The risk-factor adjusted hazard ratio for AF was 4.95 (95% confidence interval 2.06-11.9; P <.0001) for those with short irregular SVTs (<70 beats) without p waves. The incidence of ischemic stroke was highest in the group with regular SVT episodes without p waves (hazard ratio 14.2; 95% confidence interval 3.76-57.6; P <.0001, adjusted for age and sex). Characteristics of short SVT episodes detected at 24-hour ECG screening are associated with incident AF and ischemic stroke. Short irregular SVTs without p waves likely represent early stages of AF or atrial myopathy. Twenty-four-hour ECG could identify subjects suitable for primary prevention efforts. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Mechanism linking T-wave alternans to the genesis of cardiac fibrillation.
Pastore, J M; Girouard, S D; Laurita, K R; Akar, F G; Rosenbaum, D S
1999-03-16
Although T-wave alternans has been closely associated with vulnerability to ventricular arrhythmias, the cellular processes underlying T-wave alternans and their role, if any, in the mechanism of reentry remain unclear. -T-wave alternans on the surface ECG was elicited in 8 Langendorff-perfused guinea pig hearts during fixed-rate pacing while action potentials were recorded simultaneously from 128 epicardial sites with voltage-sensitive dyes. Alternans of the repolarization phase of the action potential was observed above a critical threshold heart rate (HR) (209+/-46 bpm) that was significantly lower (by 57+/-36 bpm) than the HR threshold for alternation of action potential depolarization. The magnitude (range, 2.7 to 47.0 mV) and HR threshold (range, 171 to 272 bpm) of repolarization alternans varied substantially between cells across the epicardial surface. T-wave alternans on the surface ECG was explained primarily by beat-to-beat alternation in the time course of cellular repolarization. Above a critical HR, membrane repolarization alternated with the opposite phase between neighboring cells (ie, discordant alternans), creating large spatial gradients of repolarization. In the presence of discordant alternans, a small acceleration of pacing cycle length produced a characteristic sequence of events: (1) unidirectional block of an impulse propagating against steep gradients of repolarization, (2) reentrant propagation, and (3) the initiation of ventricular fibrillation. Repolarization alternans at the level of the single cell accounts for T-wave alternans on the surface ECG. Discordant alternans produces spatial gradients of repolarization of sufficient magnitude to cause unidirectional block and reentrant ventricular fibrillation. These data establish a mechanism linking T-wave alternans of the ECG to the pathogenesis of sudden cardiac death.
Nayyar, Sachin; Hasan, Muhammad A; Roberts-Thomson, Kurt C; Sullivan, Thomas; Baumert, Mathias
2017-06-01
Heart rate variability (HRV) modulates dynamics of ventricular repolarization. A diminishing value of HRV is associated with increased vulnerability to life-threatening ventricular arrhythmias, however the causal relationship is not well-defined. We evaluated if fixed-rate atrial pacing that abolishes the effect of physiological HRV, will alter ventricular repolarization wavefronts and is relevant to ventricular arrhythmogenesis. The study was performed in 16 subjects: 8 heart failure patients with spontaneous ventricular tachycardia [HFVT], and 8 subjects with structurally normal hearts (H Norm ). The T-wave heterogeneity descriptors [total cosine angle between QRS and T-wave loop vectors (TCRT, negative value corresponds to large difference in the 2 loops), T-wave morphology dispersion, T-wave loop dispersion] and QT intervals were analyzed in a beat-to-beat manner on 3-min records of 12-lead surface ECG at baseline and during atrial pacing at 80 and 100 bpm. The global T-wave heterogeneity was expressed as mean values of each of the T-wave morphology descriptors and variability in QT intervals (QTV) as standard deviation of QT intervals. Baseline T-wave morphology dispersion and QTV were higher in HFVT compared to H Norm subjects (p ≤ 0.02). While group differences in T-wave morphology dispersion and T-wave loop dispersion remained unaltered with atrial pacing, TCRT tended to fall more in HFVT patients compared to H Norm subjects (interaction p value = 0.086). Atrial pacing failed to reduce QTV in both groups, however group differences were augmented (p < 0.0001). Atrial pacing and consequent loss of HRV appears to introduce unfavorable changes in ventricular repolarization in HFVT subjects. It widens the spatial relationship between wavefronts of ventricular depolarization and repolarization. This may partly explain the concerning relation between poorer HRV and the risk of ventricular arrhythmias.
Optical storage with electromagnetically induced transparency in cold atoms at a high optical depth
NASA Astrophysics Data System (ADS)
Zhang, Shanchao; Zhou, Shuyu; Liu, Chang; Chen, J. F.; Wen, Jianming; Loy, M. M. T.; Wong, G. K. L.; Du, Shengwang
2012-06-01
We report experimental demonstration of efficient optical storage with electromagnetically induced transparency (EIT) in a dense cold ^85Rb atomic ensemble trapped in a two-dimensional magneto-optical trap. By varying the optical depth (OD) from 0 to 140, we observe that the optimal storage efficiency for coherent optical pulses has a saturation value of 50% as OD > 50. Our result is consistent with that obtained from hot vapor cell experiments which suggest that a four-wave mixing nonlinear process degrades the EIT storage coherence and efficiency. We apply this EIT quantum memory for narrow-band single photons with controllable waveforms, and obtain an optimal storage efficiency of 49±3% for single-photon wave packets. This is the highest single-photon storage efficiency reported up to today and brings the EIT atomic quantum memory close to practical application because an efficiency of above 50% is necessary to operate the memory within non-cloning regime and beat the classical limit.
Ciliary locomotion in presence of boundaries
NASA Astrophysics Data System (ADS)
Jana, Saikat; Um, Soong Ho; Jung, Sunghwan
2010-11-01
Micro-organisms in nature navigate through a variety of fluidic geometries and chemical conditions. We investigate the effect of confined spaces in nature by introducing Paramecium Multimicronucleatum in two different configurations: a capillary tube & a wavy PDMS channel. Paramecium swims by creating the metachronal waves due to ciliary beating. The influence of the walls on Paramecia is characterized by measuring the velocity and observing the ciliary beating pattern. Theoretically, we also model the system by solving the stream-function with a pressure gradient. The theoretical and experimental observations are compared and conclusions are drawn about the change in the swimming characteristics as compared to free swimming without the boundaries.
A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring.
Yang, Tingting; Jiang, Xin; Zhong, Yujia; Zhao, Xuanliang; Lin, Shuyuan; Li, Jing; Li, Xinming; Xu, Jianlong; Li, Zhihong; Zhu, Hongwei
2017-07-28
Profuse medical information about cardiovascular properties can be gathered from pulse waveforms. Therefore, it is desirable to design a smart pulse monitoring device to achieve noninvasive and real-time acquisition of cardiovascular parameters. The majority of current pulse sensors are usually bulky or insufficient in sensitivity. In this work, a graphene-based skin-like sensor is explored for pulse wave sensing with features of easy use and wearing comfort. Moreover, the adjustment of the substrate stiffness and interfacial bonding accomplish the optimal balance between sensor linearity and signal sensitivity, as well as measurement of the beat-to-beat radial arterial pulse. Compared with the existing bulky and nonportable clinical instruments, this highly sensitive and soft sensing patch not only provides primary sensor interface to human skin, but also can objectively and accurately detect the subtle pulse signal variations in a real-time fashion, such as pulse waveforms with different ages, pre- and post-exercise, thus presenting a promising solution to home-based pulse monitoring.
Rayleigh-enhanced attosecond sum-frequency polarization beats via twin color-locking noisy lights
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Yanpeng; Li Long; Ma Ruiqiong
2005-07-15
Based on color-locking noisy field correlation, a time-delayed method is proposed to suppress the thermal effect, and the ultrafast longitudinal relaxation time can be measured even in an absorbing medium. One interesting feature in field-correlation effects is that Rayleigh-enhanced four-wave mixing (RFWM) with color-locking noisy light exhibits spectral symmetry and temporal asymmetry with no coherence spike at {tau}=0. Due to the interference between the Rayleigh-resonant signal and the nonresonant background, RFWM exhibits hybrid radiation-matter detuning with terahertz damping oscillations. The subtle Markovian high-order correlation effects have been investigated in the homodyne- or heterodyne-detected Rayleigh-enhanced attosecond sum-frequency polarization beats (RASPBs). Analyticmore » closed forms of fourth-order Markovian stochastic correlations are characterized for homodyne (quadratic) and heterodyne (linear) detection, respectively. Based on the polarization interference between two four-wave mixing processes, the phase-sensitive detection of RASPBs has also been used to obtain the real and imaginary parts of the Rayleigh resonance.« less
Healthcare performance and the effects of the binaural beats on human blood pressure and heart rate.
Carter, Calvin
2008-01-01
Binaural beats are the differences in two different frequencies (in the range of 30-1000 Hz). Binaural beats are played through headphones and are perceived by the superior olivary nucleus of each hemisphere of the brain. The brain perceives the binaural beat and resonates to its frequency (frequency following response). Once the brain is in tune with the binaural beat it produces brainwaves of that frequency altering the listener's state of mind. In this experiment, the effects of the beta and theta binaural beat on human blood pressure and pulse were studied. Using headphones, three sounds were played for 7 minutes each to 12 participants: the control,- the sound of a babbling brook (the background sound to the two binaural beats), the beta binaural beat (20 Hz), and the theta binaural beat (7 Hz). Blood pressure and pulse were recorded before and after each sound was played. Each participant was given 2 minutes in-between each sound. The results showed that the control and the two binaural beats did not affect the 12 participant's blood pressure or pulse (p > 0.05). One reason for this may be that the sounds were not played long enough for the brain to either perceive and/or resonate to the frequency. Another reason why the sounds did not affect blood pressure and pulse may be due to the participant's age since older brains may not perceive the binaural beats as well as younger brains.
Beliefs about wife beating: an exploratory study with Lebanese students.
Obeid, Nadine; Chang, Doris F; Ginges, Jeremy
2010-06-01
In recent years, there has been a growing interest in understanding the sociocultural contexts and risk factors for domestic violence in the Arab world. This study provides an analysis of the religious, legal, and familial contexts of domestic violence in Lebanon and assesses contemporary attitudes toward women and wife beating in a sample of 206 Lebanese university students. Gender, patriarchal attitudes, religion, childhood experiences with family violence, and mother's employment status were investigated as predictors of attitudes toward wife beating. Consistent with feminist theories of wife abuse, gender and attitudes toward women's roles emerged as the strongest predictors of beliefs about wife beating.
Kodama, Hiroyuki; Fujita, Kazumasa; Moriyama, Shouhei; Irie, Kei; Noda, Hirotaka; Yokoyama, Taku; Fukata, Mitsuhiro; Arita, Takeshi; Odashiro, Keita; Maruyama, Toru; Akashi, Koichi
2017-06-01
A 51-year-old man with a resuscitation episode was referred to our hospital. Coronary angiography revealed a focal spasm overlapped with organic stenosis where a bare metal stent was implanted. Acetylcholine (ACh) provocation test did not induce chest pain. It revealed no discernible ST-T changes but unmasked a J wave at the end of the QRS complex, which was associated with short-coupled repetitive premature ventricular beats. A J wave reportedly appears immediately before the onset of ventricular fibrillation caused by vasospastic angina. However, a J wave observed newly after a coronary spasm provocation test using ACh without ST-T changes is informative when considering the mechanisms of the J wave.
Effect of confinements: Bending in Paramecium
NASA Astrophysics Data System (ADS)
Eddins, Aja; Yang, Sung; Spoon, Corrie; Jung, Sunghwan
2012-02-01
Paramecium is a unicellular eukaryote which by coordinated beating of cilia, generates metachronal waves which causes it to execute a helical trajectory. We investigate the swimming parameters of the organism in rectangular PDMS channels and try to quantify its behavior. Surprisingly a swimming Paramecium in certain width of channels executes a bend of its flexible body (and changes its direction of swimming) by generating forces using the cilia. Considering a simple model of beam constrained between two walls, we predict the bent shapes of the organism and the forces it exerts on the walls. Finally we try to explain how bending (by sensing) can occur in channels by conducting experiments in thin film of fluid and drawing analogy to swimming behavior observed in different cases.
Intercepting beats in predesignated target zones.
Craig, Cathy; Pepping, Gert-Jan; Grealy, Madeleine
2005-09-01
Moving to a rhythm necessitates precise timing between the movement of the chosen limb and the timing imposed by the beats. However, the temporal information specifying the moment when a beat will sound (the moment onto which one must synchronise one's movement) is not continuously provided by the acoustic array. Because of this informational void, the actors need some form of prospective information that will allow them to act sufficiently ahead of time in order to get their hand in the right place at the right time. In this acoustic interception study, where participants were asked to move between two targets in such a way that they arrived and stopped in the target zone at the same time as a beat sounded, we tested a model derived from tau-coupling theory (Lee DN (1998) Ecol Psychol 10:221-250). This model attempts to explain the form of a potential timing guide that specifies the duration of the inter-beat intervals and also describes how this informational guide can be used in the timing and guidance of movements. The results of our first experiment show that, for inter-beat intervals of less than 3 s, a large proportion of the movement (over 70%) can be explained by the proposed model. However, a second experiment, which augments the time between beats so that it surpasses 3 s, shows a marked decline in the percentage of information/movement coupling. A close analysis of the movement kinematics indicates a lack of control and anticipation in the participants' movements. The implications of these findings, in light of other research studies, are discussed.
The Moire Effect in Physics Teaching.
ERIC Educational Resources Information Center
Bernero, Bruce
1989-01-01
The Moire pattern is the shimmering pattern which looks like an odd interference pattern in window screens or folds of nylon shower curtain. Illustrates some of the ways the effect may be used, including demonstration of wave interference, detection of small displacement, persistence of vision, contour measurement, beats, and optical clearness.…
European Scientific Notes. Volume 35, Number 8,
1981-08-31
the frustrating task than the civilians did (about 75 beats per minute compared to 82); but the decorated group had still lower heartbeat rates...loud stimulus (1000 Hz sine wave, 30 msec duration) via binaural earphones. EEC data were sampled at 0.5 msec intervals; records were edited to
The effects of continuous and amplitude-modulated radiofrequency electromagnetic waves on calcium efflux from 45Ca preloaded frog hearts were examined. rog hearts, electrically stimulated at their natural beating frequency, were exposed for 30 min to 240 MHz radiowaves in a Crawf...
Computer-Generated Diagrams for the Classroom.
ERIC Educational Resources Information Center
Carle, Mark A.; Greenslade, Thomas B., Jr.
1986-01-01
Describes 10 computer programs used to draw diagrams usually drawn on chalkboards, such as addition of three vectors, vector components, range of a projectile, lissajous figures, beats, isotherms, Snell's law, waves passing through a lens, magnetic field due to Helmholtz coils, and three curves. Several programming tips are included. (JN)
Heating Efficiency of Beat Wave Excitation in a Density Gradient,
1988-02-01
and Technology, January 1988. PPG-1124 Research Highlights in The Pisces Program," R.V. Conn, et al, January 1988. PPG-1125 "Magnetic Fusion ... Energy , vol. 5. Technical Assessement of Critical Issues in the Steady State Operation of Fusion Confinement Devices," D. M. Goebel, Assessment Chairman
Laser beat wave excitation of terahertz radiation in a plasma slab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chauhan, Santosh; Parashar, Jetendra, E-mail: j.p.parashar@gmail.com
2014-10-15
Terahertz (THz) radiation generation by nonlinear mixing of lasers, obliquely incident on a plasma slab is investigated. Two cases are considered: (i) electron density profile is parabolic but density peak is below the critical density corresponding to the beat frequency, (ii) plasma boundaries are sharp and density is uniform. In both cases, nonlinearity arises through the ponderomotive force that gives rise to electron drift at the beat frequency. In the case of inhomogeneous plasma, non zero curl of the nonlinear current density gives rise to electromagnetic THz generation. In case of uniform plasma, the sharp density variation at the plasmamore » boundaries leads to radiation generation. In a slab width of less than a terahertz wavelength, plasma density one fourth of terahertz critical density, laser intensities ∼10{sup 17 }W/cm{sup 2} at 1 μm, one obtains the THz intensity ∼1 GW/cm{sup 2} at 3 THz radiation frequency.« less
Mechanical signaling coordinates the embryonic heart
NASA Astrophysics Data System (ADS)
Chiou, Kevin; Rocks, Jason; Prosser, Benjamin; Discher, Dennis; Liu, Andrea
The heart is an active material which relies on robust signaling mechanisms between cells in order to produce well-timed, coordinated beats. Heart tissue is composed primarily of active heart muscle cells (cardiomyocytes) embedded in a passive extracellular matrix. During a heartbeat, cardiomyocyte contractions are coordinated across the heart to form a wavefront that propagates through the tissue to pump blood. In the adult heart, this contractile wave is coordinated via intercellular electrical signaling.Here we present theoretical and experimental evidence for mechanical coordination of embryonic heartbeats. We model cardiomyocytes as mechanically excitable Eshelby inclusions embedded in an overdamped elastic-fluid biphasic medium. For physiological parameters, this model replicates recent experimental measurements of the contractile wavefront which are not captured by electrical signaling models. We additionally challenge our model by pharmacologically blocking gap junctions, inhibiting electrical signaling between myocytes. We find that while adult hearts stop beating almost immediately after gap junctions are blocked, embryonic hearts continue beating even at significantly higher concentrations, providing strong support for a mechanical signaling mechanism.
Soliton radiation beat analysis of optical pulses generated from two continuous-wave lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zajnulina, M.; Giannone, D.; Haynes, R.
We propose a fibre-based approach for generation of optical frequency combs (OFCs) with the aim of calibration of astronomical spectrographs in the low and medium-resolution range. This approach includes two steps: in the first step, an appropriate state of optical pulses is generated and subsequently moulded in the second step delivering the desired OFC. More precisely, the first step is realised by injection of two continuous-wave (CW) lasers into a conventional single-mode fibre, whereas the second step generates a broad OFC by using the optical solitons generated in step one as initial condition. We investigate the conversion of a bichromaticmore » input wave produced by two initial CW lasers into a train of optical solitons, which happens in the fibre used as step one. Especially, we are interested in the soliton content of the pulses created in this fibre. For that, we study different initial conditions (a single cosine-hump, an Akhmediev breather, and a deeply modulated bichromatic wave) by means of soliton radiation beat analysis and compare the results to draw conclusion about the soliton content of the state generated in the first step. In case of a deeply modulated bichromatic wave, we observed the formation of a collective soliton crystal for low input powers and the appearance of separated solitons for high input powers. An intermediate state showing the features of both, the soliton crystal and the separated solitons, turned out to be most suitable for the generation of OFC for the purpose of calibration of astronomical spectrographs.« less
Dynamic cycling in atrial size and flow during obstructive apnoea.
Pressman, Gregg S; Cepeda-Valery, Beatriz; Codolosa, Nicolas; Orban, Marek; Samuel, Solomon P; Somers, Virend K
2016-01-01
Obstructive sleep apnoea (OSA) is strongly associated with cardiovascular disease. However, acute cardiovascular effects of repetitive airway obstruction are poorly understood. While past research used a sustained Mueller manoeuver to simulate OSA we employed a series of gasping efforts to better simulate true obstructive apnoeas. This report describes acute changes in cardiac anatomy and flow related to sudden changes in intrathoracic pressure. 26 healthy, normal weight participants performed 5-6 gasping efforts (target intrathoracic pressure -40 mm Hg) while undergoing Doppler echocardiography. 14 participants had sufficient echocardiographic images to allow comparison of atrial areas during the manoeuver with baseline measurements. Mitral and tricuspid E-wave and A-wave velocities postmanoeuver were compared with baseline in all participants. Average atrial areas changed little during the manoeuver, but variance in both atrial areas was significantly greater than baseline. Further, an inverse relationship was noted with left atrial collapse and right atrial enlargement at onset of inspiratory effort. Significant inverse changes were noted in Doppler flow when comparing the first beat postmanoeuver (pMM1) with baseline. Mitral E-wave velocity increased 9.1 cm/s while tricuspid E-wave velocity decreased 7.0 cm/s; by the eighth beat postmanoeuver (pMM8) values were not different from baseline. Mitral and tricuspid A-wave velocities were not different from baseline at pMM1, but both were significantly higher by pMM8. Repetitive obstructive apnoeas produce dynamic, inverse changes in atrial size and Doppler flow across the atrioventricular valves. These observations have important implications for understanding the pathophysiology of OSA.
Soliton radiation beat analysis of optical pulses generated from two continuous-wave lasers.
Zajnulina, M; Böhm, M; Blow, K; Rieznik, A A; Giannone, D; Haynes, R; Roth, M M
2015-10-01
We propose a fibre-based approach for generation of optical frequency combs (OFCs) with the aim of calibration of astronomical spectrographs in the low and medium-resolution range. This approach includes two steps: in the first step, an appropriate state of optical pulses is generated and subsequently moulded in the second step delivering the desired OFC. More precisely, the first step is realised by injection of two continuous-wave (CW) lasers into a conventional single-mode fibre, whereas the second step generates a broad OFC by using the optical solitons generated in step one as initial condition. We investigate the conversion of a bichromatic input wave produced by two initial CW lasers into a train of optical solitons, which happens in the fibre used as step one. Especially, we are interested in the soliton content of the pulses created in this fibre. For that, we study different initial conditions (a single cosine-hump, an Akhmediev breather, and a deeply modulated bichromatic wave) by means of soliton radiation beat analysis and compare the results to draw conclusion about the soliton content of the state generated in the first step. In case of a deeply modulated bichromatic wave, we observed the formation of a collective soliton crystal for low input powers and the appearance of separated solitons for high input powers. An intermediate state showing the features of both, the soliton crystal and the separated solitons, turned out to be most suitable for the generation of OFC for the purpose of calibration of astronomical spectrographs.
Soliton radiation beat analysis of optical pulses generated from two continuous-wave lasers
NASA Astrophysics Data System (ADS)
Zajnulina, M.; Böhm, M.; Blow, K.; Rieznik, A. A.; Giannone, D.; Haynes, R.; Roth, M. M.
2015-10-01
We propose a fibre-based approach for generation of optical frequency combs (OFCs) with the aim of calibration of astronomical spectrographs in the low and medium-resolution range. This approach includes two steps: in the first step, an appropriate state of optical pulses is generated and subsequently moulded in the second step delivering the desired OFC. More precisely, the first step is realised by injection of two continuous-wave (CW) lasers into a conventional single-mode fibre, whereas the second step generates a broad OFC by using the optical solitons generated in step one as initial condition. We investigate the conversion of a bichromatic input wave produced by two initial CW lasers into a train of optical solitons, which happens in the fibre used as step one. Especially, we are interested in the soliton content of the pulses created in this fibre. For that, we study different initial conditions (a single cosine-hump, an Akhmediev breather, and a deeply modulated bichromatic wave) by means of soliton radiation beat analysis and compare the results to draw conclusion about the soliton content of the state generated in the first step. In case of a deeply modulated bichromatic wave, we observed the formation of a collective soliton crystal for low input powers and the appearance of separated solitons for high input powers. An intermediate state showing the features of both, the soliton crystal and the separated solitons, turned out to be most suitable for the generation of OFC for the purpose of calibration of astronomical spectrographs.
Giassi, Pedro; Okida, Sergio; Oliveira, Maurício G; Moraes, Raimes
2013-11-01
Short-term cardiovascular regulation mediated by the sympathetic and parasympathetic branches of the autonomic nervous system has been investigated by multivariate autoregressive (MVAR) modeling, providing insightful analysis. MVAR models employ, as inputs, heart rate (HR), systolic blood pressure (SBP) and respiratory waveforms. ECG (from which HR series is obtained) and respiratory flow waveform (RFW) can be easily sampled from the patients. Nevertheless, the available methods for acquisition of beat-to-beat SBP measurements during exams hamper the wider use of MVAR models in clinical research. Recent studies show an inverse correlation between pulse wave transit time (PWTT) series and SBP fluctuations. PWTT is the time interval between the ECG R-wave peak and photoplethysmography waveform (PPG) base point within the same cardiac cycle. This study investigates the feasibility of using inverse PWTT (IPWTT) series as an alternative input to SBP for MVAR modeling of the cardiovascular regulation. For that, HR, RFW, and IPWTT series acquired from volunteers during postural changes and autonomic blockade were used as input of MVAR models. Obtained results show that IPWTT series can be used as input of MVAR models, replacing SBP measurements in order to overcome practical difficulties related to the continuous sampling of the SBP during clinical exams.
Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Fletcher, Richard R; Abbott, Derek; Lovell, Nigel H; Schuurmans, Dale
2015-10-14
Recent clinical studies show that the contour of the photoplethysmogram (PPG) wave contains valuable information for characterizing cardiovascular activity. However, analyzing the PPG wave contour is difficult; therefore, researchers have applied first or higher order derivatives to emphasize and conveniently quantify subtle changes in the filtered PPG contour. Our hypothesis is that analyzing the whole PPG recording rather than each PPG wave contour or on a beat-by-beat basis can detect heat-stressed subjects and that, consequently, we will be able to investigate the impact of global warming on human health. Here, we explore the most suitable derivative order for heat stress assessment based on the energy and entropy of the whole PPG recording. The results of our study indicate that the use Int. J. Environ. Res. Public Health 2015, 7 12777 of the entropy of the seventh derivative of the filtered PPG signal shows promising results in detecting heat stress using 20-second recordings, with an overall accuracy of 71.6%. Moreover, the combination of the entropy of the seventh derivative of the filtered PPG signal with the root mean square of successive differences, or RMSSD (a traditional heart rate variability index of heat stress), improved the detection of heat stress to 88.9% accuracy.
Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography
Penzel, Thomas; Kantelhardt, Jan W.; Bartsch, Ronny P.; Riedl, Maik; Kraemer, Jan F.; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph
2016-01-01
The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave). PMID:27826247
Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.
Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph
2016-01-01
The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).
Simulation of heart infarction by laser microbeams and induction of arrhythmias by optical tweezers
NASA Astrophysics Data System (ADS)
Perner, Birgit; Monajembashi, Shamci; Rapp, Alexander; Wollweber, Leo; Greulich, Karl Otto
2004-10-01
Laser microbeam and optical tweezers were used for micromanipulation of a heart tissue model consisting of embryonic chicken cardiomyocytes and bibroblasts. Using the laser microbeam a would was created, i.e. a sort of artificial heart infarction was generated. The first steps of wound repair were observed by live cell imaging. A complete filling of teh would primarily by migrating fibroblasts but not by cardiomyocytes was detected 18 hours after wounding. In another set of experiments erythrocyte mediated force application (EMFA) by optical tweezers was applied for optomechanical manipulatoin of cardiomyocytes and fibroblasts. Here we demonstrate induction of dramatic distrubances of calcium waves in a group of synchronously beating cardiomyocytes by an optomechanical input that results in cellular deformation. Surprisingly, it was found that putatively non-excitable fibroblasts respond to this mechanical stress with calcium oscillations. The results reported here indicate that the induction of artificial heart infarction can provide insights into healing processes after mycardial injury. EMFA is capable to examine effects of myocardial overload and to provide important information about processes triggered by mechanical stress on the level of single or very few cells. As a perspective, the preseneted techniques may be used to study the influence of drugs on wound healing and coordination of beating in the heart.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, D.D.; Jones, H.E.
1994-05-06
Prosthetic heart valves have increased the life span of many patients with life threatening heart conditions. These valves have proven extremely reliable adding years to what would have been weeks to a patient`s life. Prosthetic valves, like the heart however, can suffer from this constant work load. A small number of valves have experienced structural fractures of the outlet strut due to fatigue. To study this problem a non-intrusive method to classify valves has been developed. By extracting from an acoustic signal the opening sounds which directly contain information from the outlet strut and then developing features which are suppliedmore » to an adaptive classification scheme (neural network) the condition of the valve can be determined. The opening sound extraction process has proved to be a classification problem itself. Due to the uniqueness of each heart and the occasional irregularity of the acoustic pattern it is often questionable as to the integrity of a given signal (beat), especially one occurring during an irregular beat pattern. A common cause of these irregular patterns is a condition known as atrial fibrillation, a prevalent arrhythmia among patients with prosthetic hear valves. Atrial fibrillation is suspected when the ECG shows no obvious P-waves. The atria do not contract and relax correctly to help contribute to ventricular filling during a normal cardiac cycle. Sometimes this leads to irregular patterns in the acoustic data. This study compares normal beat patterns to irregular patterns of the same heart. By analyzing the spectral content of the beats it can be determined whether or not these irregular patterns can contribute to the classification of a heart valve or if they should be avoided. The results have shown that the opening sounds which occur during irregular beat patterns contain the same spectral information as the opening which occur during a normal beat pattern of the same heart and these beats can be used for classification.« less
NASA Astrophysics Data System (ADS)
Liu, Lisheng; Zhang, Heyong; Guo, Jin; Zhao, Shuai; Wang, Tingfeng
2012-08-01
In this paper, we report a mathematical derivation of probability density function (PDF) of time-interval between two successive photoelectrons of the laser heterodyne signal, and give a confirmation of the theoretical result by both numerical simulation and an experiment. The PDF curve of the beat signal displays a series of fluctuations, the period and amplitude of which are respectively determined by the beat frequency and the mixing efficiency. The beat frequency is derived from the frequency of fluctuations accordingly when the PDF curve is measured. This frequency measurement method still works while the traditional Fast Fourier Transform (FFT) algorithm hardly derives the correct peak value of the beat frequency in the condition that we detect 80 MHz beat signal with 8 Mcps (counts per-second) photons count rate, and this indicates an advantage of the PDF method.
Selective neuronal entrainment to the beat and meter embedded in a musical rhythm.
Nozaradan, Sylvie; Peretz, Isabelle; Mouraux, André
2012-12-05
Fundamental to the experience of music, beat and meter perception refers to the perception of periodicities while listening to music occurring within the frequency range of musical tempo. Here, we explored the spontaneous building of beat and meter hypothesized to emerge from the selective entrainment of neuronal populations at beat and meter frequencies. The electroencephalogram (EEG) was recorded while human participants listened to rhythms consisting of short sounds alternating with silences to induce a spontaneous perception of beat and meter. We found that the rhythmic stimuli elicited multiple steady state-evoked potentials (SS-EPs) observed in the EEG spectrum at frequencies corresponding to the rhythmic pattern envelope. Most importantly, the amplitude of the SS-EPs obtained at beat and meter frequencies were selectively enhanced even though the acoustic energy was not necessarily predominant at these frequencies. Furthermore, accelerating the tempo of the rhythmic stimuli so as to move away from the range of frequencies at which beats are usually perceived impaired the selective enhancement of SS-EPs at these frequencies. The observation that beat- and meter-related SS-EPs are selectively enhanced at frequencies compatible with beat and meter perception indicates that these responses do not merely reflect the physical structure of the sound envelope but, instead, reflect the spontaneous emergence of an internal representation of beat, possibly through a mechanism of selective neuronal entrainment within a resonance frequency range. Taken together, these results suggest that musical rhythms constitute a unique context to gain insight on general mechanisms of entrainment, from the neuronal level to individual level.
Stapf, Daniel; Franke, Andreas; Schreckenberg, Marcus; Schummers, Georg; Mischke, Karl; Marx, Nikolaus; Schauerte, Patrick; Knackstedt, Christian
2013-04-01
Three-dimensional (3D)-imaging provides important information on cardiac anatomy during electrophysiological procedures. Real-time updates of modalities with high soft-tissue contrast are particularly advantageous during cardiac procedures. Therefore, a beat to beat 3D visualization of cardiac anatomy by intracardiac echocardiography (ICE) was developed and tested in phantoms and animals. An electronic phased-array 5-10 MHz ICE-catheter (Acuson, AcuNav/Siemens Medical Solutions USA/64 elements) providing a 90° sector image was used for ICE-imaging. A custom-made mechanical prototype controlled by a servo motor allowed automatic rotation of the ICE-catheter around its longitudinal axis. During a single heartbeat, the ICE-catheter was rotated and 2D-images were acquired. Reconstruction into a 3D volume and rendering by a prototype software was performed beat to beat. After experimental validation using a rigid phantom, the system was tested in an animal study and afterwards, for quantitative validation, in a dynamic phantom. Acquisition of beat to beat 3D-reconstruction was technically feasible. However, twisting of the ICE-catheter shaft due to friction and torsion was found and rotation was hampered. Also, depiction of catheters was not always ensured in case of parallel alignment. Using a curved sheath for depiction of cardiac anatomy there was no congruent depiction of shape and dimension of static and moving objects. Beat to beat 3D-ICE-imaging is feasible. However, shape and dimension of static and moving objects cannot always be displayed with necessary steadiness as needed in the clinical setting. As catheter depiction is also limited, clinical use seems impossible.
Successful surgical treatment of mitral valve stenosis in a dog.
Borenstein, N; Daniel, P; Behr, L; Pouchelon, J L; Carbognani, D; Pierrel, A; Macabet, V; Lacheze, A; Jamin, G; Carlos, C; Chetboul, V; Laborde, F
2004-01-01
To report the successful surgical management (open mitral commissurotomy, OMC) of mitral stenosis (MS), incorporating heart-beating cardiopulmonary bypass (CPB), in a 1-year-old dog. Clinical case. One-year-old Cairn Terrier with MS. Diagnosis of MS was confirmed by means of 2-dimensional, continuous-wave and color-flow Doppler echocardiography. Surgery was performed through a left intercostal thoracotomy. CPB was initiated and the heart was kept beating. The fused commissures of the mitral valve were incised to free the cusps of the valve. Left intercostal thoracotomy allowed easy observation of the mitral orifice during heart-beating OMC. Persistent bleeding from the atriotomy site required a second surgical procedure after which the dog had an uneventful recovery. Echocardiography at 2 weeks and 1 year postoperatively indicated substantial improvement in left ventricular filling (pressure half-time=187 ms before surgery, 105 ms [2 weeks] and 110 ms [1 year] after surgery). Enlargement of the left atrium resolved; however, moderate mitral valve regurgitation was still present. MS can be successfully treated by OMC, facilitated by use of CPB. Substantial improvement in cardiac function was evident by ultrasound and Doppler examination postoperatively. OMC under heart-beating CPB should be considered for the treatment of MS in the dog.
Floré, Vincent; Claus, Piet; Antoons, Gudrun; Oosterhoff, Peter; Holemans, Patricia; Vos, Marc A; Sipido, Karin R; Willems, Rik
2011-07-01
Repolarization variability is considered to predict sudden cardiac death. T-wave alternans (TWA) has been the subject of exhaustive research, whereas beat-to-beat variability of repolarization (BVR) is a new parameter that possibly predicts proarrhythmia. How these parameters interact has not been tested. The purpose of this study was to compare TWA and BVR as predictors of proarrhythmic substrate early after myocardial infarction (MI). In nine pigs, MI was induced by 1-hour occlusion of the left anterior descending coronary artery. Cardiac magnetic resonance imaging was performed at day 21. Six sham pigs served as control. Spectral TWA was tested during right atrial pacing before induction of MI and after 21 days. BVR was calculated from 60 consecutive QT intervals. Magnetic resonance imaging showed transmural MI. TWA was negative in all pigs at clinical threshold rate and equally present in MI versus sham pigs at higher rates (170 bpm: 55% vs 50% positive TWA). In MI pigs, BVR of QT intervals increased significantly during acute ischemia (2.44 ± 0.43 ms vs 3.55 ± 0.41 ms, P <.01) and even more on day 21 (5.80 ± 1.12 ms), but it differed significantly from sham (2.14 ± 0.54 ms, P <.01). A clinical ventricular tachycardia induction protocol was positive in 2 of 8 MI pigs and in none of 6 shams. In early remodeling after MI, BVR at intrinsic heart rate was a consistent phenomenon, whereas TWA during atrial pacing or baseline QT-interval changes were not. TWA and BVR could reflect different post-MI remodeling processes. BVR may be a new technique for predicting a potentially proarrhythmic substrate in the early postinfarction period. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Edla, Shwetha; Kovvali, Narayan; Papandreou-Suppappola, Antonia
2012-01-01
Constructing statistical models of electrocardiogram (ECG) signals, whose parameters can be used for automated disease classification, is of great importance in precluding manual annotation and providing prompt diagnosis of cardiac diseases. ECG signals consist of several segments with different morphologies (namely the P wave, QRS complex and the T wave) in a single heart beat, which can vary across individuals and diseases. Also, existing statistical ECG models exhibit a reliance upon obtaining a priori information from the ECG data by using preprocessing algorithms to initialize the filter parameters, or to define the user-specified model parameters. In this paper, we propose an ECG modeling technique using the sequential Markov chain Monte Carlo (SMCMC) filter that can perform simultaneous model selection, by adaptively choosing from different representations depending upon the nature of the data. Our results demonstrate the ability of the algorithm to track various types of ECG morphologies, including intermittently occurring ECG beats. In addition, we use the estimated model parameters as the feature set to classify between ECG signals with normal sinus rhythm and four different types of arrhythmia.
Single source photoplethysmograph transducer for local pulse wave velocity measurement.
Nabeel, P M; Joseph, Jayaraj; Awasthi, Vartika; Sivaprakasam, Mohanasankar
2016-08-01
Cuffless evaluation of arterial blood pressure (BP) using pulse wave velocity (PWV) has received attraction over the years. Local PWV based techniques for cuffless BP measurement has more potential in accurate estimation of BP parameters. In this work, we present the design and experimental validation of a novel single-source Photoplethysmograph (PPG) transducer for arterial blood pulse detection and cycle-to-cycle local PWV measurement. The ability of the transducer to continuously measure local PWV was verified using arterial flow phantom as well as by conducting an in-vivo study on 17 volunteers. The single-source PPG transducer could reliably acquire dual blood pulse waveforms, along small artery sections of length less than 28 mm. The transducer was able to perform repeatable measurements of carotid local PWV on multiple subjects with maximum beat-to-beat variation less than 12%. The correlation between measured carotid local PWV and brachial BP parameters were also investigated during the in-vivo study. Study results prove the potential use of newly proposed single-source PPG transducers in continuous cuffless BP measurement systems.
Experimental implementation of phase locking in a nonlinear interferometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hailong; Jing, Jietai, E-mail: jtjing@phy.ecnu.edu.cn; Marino, A. M.
2015-09-21
Based upon two cascade four-wave mixing processes in two identical hot rubidium vapor cells, a nonlinear interferometer has been experimentally realized [Jing et al., Appl. Phys. Lett. 99, 011110 (2011); Hudelist et al., Nat. Commun. 5, 3049 (2014)]. It has a higher degree of phase sensitivity than a traditional linear interferometer and has many potential applications in quantum metrology. Phase locking of the nonlinear interferometer is needed before it can find its way into applications. In this letter, we investigate the experimental implementation of phase locking of the relative phase between the three beams at different frequencies involved in suchmore » a nonlinear interferometer. We have utilized two different methods, namely, beat note locking and coherent modulation locking. We find that coherent modulation locking can achieve much better phase stability than beat note locking in our system. Our results pave the way for real applications of a nonlinear interferometer in precision measurement and quantum manipulation, for example, phase control in phase-sensitive N-wave mixing process, N-port nonlinear interferometer and quantum-enhanced real-time phase tracking.« less
Antonioletti, Mario; Biktashev, Vadim N; Jackson, Adrian; Kharche, Sanjay R; Stary, Tomas; Biktasheva, Irina V
2017-01-01
The BeatBox simulation environment combines flexible script language user interface with the robust computational tools, in order to setup cardiac electrophysiology in-silico experiments without re-coding at low-level, so that cell excitation, tissue/anatomy models, stimulation protocols may be included into a BeatBox script, and simulation run either sequentially or in parallel (MPI) without re-compilation. BeatBox is a free software written in C language to be run on a Unix-based platform. It provides the whole spectrum of multi scale tissue modelling from 0-dimensional individual cell simulation, 1-dimensional fibre, 2-dimensional sheet and 3-dimensional slab of tissue, up to anatomically realistic whole heart simulations, with run time measurements including cardiac re-entry tip/filament tracing, ECG, local/global samples of any variables, etc. BeatBox solvers, cell, and tissue/anatomy models repositories are extended via robust and flexible interfaces, thus providing an open framework for new developments in the field. In this paper we give an overview of the BeatBox current state, together with a description of the main computational methods and MPI parallelisation approaches.
NASA Astrophysics Data System (ADS)
Ochoukov, R.; Bobkov, V.; Faugel, H.; Fünfgelder, H.; Noterdaeme, J.-M.
2015-11-01
A new B-dot probe-based diagnostic has been installed on an ASDEX Upgrade tokamak to characterize ion cyclotron range-of frequency (ICRF) wave generation and interaction with magnetized plasma. The diagnostic consists of a field-aligned array of B-dot probes, oriented to measure fast and slow ICRF wave fields and their field-aligned wavenumber (k//) spectrum on the low field side of ASDEX Upgrade. A thorough description of the diagnostic and the supporting electronics is provided. In order to compare the measured dominant wavenumber of the local ICRF fields with the expected spectrum of the launched ICRF waves, in-air near-field measurements were performed on the newly installed 3-strap ICRF antenna to reconstruct the dominant launched toroidal wavenumbers (ktor). Measurements during a strap current phasing scan in tokamak discharges reveal an upshift in k// as strap phasing is moved away from the dipole configuration. This result is the opposite of the ktor trend expected from in-air near-field measurements; however, the near-field based reconstruction routine does not account for the effect of induced radiofrequency (RF) currents in the passive antenna structures. The measured exponential increase in the local ICRF wave field amplitude is in agreement with the upshifted k//, as strap phasing moves away from the dipole configuration. An examination of discharges heated with two ICRF antennas simultaneously reveals the existence of beat waves at 1 kHz, as expected from the difference of the two antennas' operating frequencies. Beats are observed on both the fast and the slow wave probes suggesting that the two waves are coupled outside the active antennas. Although the new diagnostic shows consistent trends between the amplitude and the phase measurements in response to changes applied by the ICRF antennas, the disagreement with the in-air near-field measurements remains. An electromagnetic model is currently under development to address this issue.
Ochoukov, R; Bobkov, V; Faugel, H; Fünfgelder, H; Noterdaeme, J-M
2015-11-01
A new B-dot probe-based diagnostic has been installed on an ASDEX Upgrade tokamak to characterize ion cyclotron range-of frequency (ICRF) wave generation and interaction with magnetized plasma. The diagnostic consists of a field-aligned array of B-dot probes, oriented to measure fast and slow ICRF wave fields and their field-aligned wavenumber (k(//)) spectrum on the low field side of ASDEX Upgrade. A thorough description of the diagnostic and the supporting electronics is provided. In order to compare the measured dominant wavenumber of the local ICRF fields with the expected spectrum of the launched ICRF waves, in-air near-field measurements were performed on the newly installed 3-strap ICRF antenna to reconstruct the dominant launched toroidal wavenumbers (k(tor)). Measurements during a strap current phasing scan in tokamak discharges reveal an upshift in k(//) as strap phasing is moved away from the dipole configuration. This result is the opposite of the k(tor) trend expected from in-air near-field measurements; however, the near-field based reconstruction routine does not account for the effect of induced radiofrequency (RF) currents in the passive antenna structures. The measured exponential increase in the local ICRF wave field amplitude is in agreement with the upshifted k(//), as strap phasing moves away from the dipole configuration. An examination of discharges heated with two ICRF antennas simultaneously reveals the existence of beat waves at 1 kHz, as expected from the difference of the two antennas' operating frequencies. Beats are observed on both the fast and the slow wave probes suggesting that the two waves are coupled outside the active antennas. Although the new diagnostic shows consistent trends between the amplitude and the phase measurements in response to changes applied by the ICRF antennas, the disagreement with the in-air near-field measurements remains. An electromagnetic model is currently under development to address this issue.
Ciobanu, Ana; Tse, Gary; Liu, Tong; Deaconu, Maria V; Gheorghe, Gabriela S; Ilieşiu, Adriana M; Nanea, Ioan T
2017-01-01
Objective To examine the relationship between Tpeak- Tend interval (Tpe) and Tpe/QT ratio with occurrence of ventricular premature beats (VPBs) and left ventricular remodeling in hypertension. Methods A total of 52 patients with mild to moderate essential hypertension were included, undergoing echocardiography and 24-hours Holter monitoring. Ventricular remodeling was assessed by left ventricular mass index (LVMI) using the Devereux formula and diastolic function by transmitral E and A wave velocities and E/A ratio. Tpe was measured in the precordial leads. The end of the T wave was set by the method of the tangent to the steepest descending slope of the T wave. Results Tpe and Tpe/QT in leads V2 (r = 0.33, P = 0.01; r = 0.27, P = 0.04 respectively) and V3 (r = 0.40, P = 0.002; r = 0.40, P = 0.003, respectively) correlated significantly with LVMI. A significant inverse relationship was observed between E/A ratio and QT (r = −0.33, P = 0.01), Tpe in V3 (r = −0.39, P = 0.003) and Tpe/QT in V3 (r = −0.31, P = 0.02). Tpe in V3, V5, mean Tpe and maximum Tpe with cut-off values of 60 ms, 59 ms, 62 ms and 71 ms, respectively, associated with the occurrence of ventricular premature beats. Conclusions The repolarization parameters Tpe interval and Tpe/QT ratio correlate with LVMI and indices of left ventricular diastolic function and show better predictive values than traditional parameters such as QT interval and QT dispersion. Lead V3 is the best lead for measuring Tpe and Tpe/QT. These ECG indices can therefore be used in clinical practice to monitor LV remodeling and predict occurrence of VPBs. PMID:29581710
Electromagnetic induction and radiation-induced abnormality of wave propagation in excitable media
NASA Astrophysics Data System (ADS)
Ma, Jun; Wu, Fuqiang; Hayat, Tasawar; Zhou, Ping; Tang, Jun
2017-11-01
Continuous wave emitting from sinus node of the heart plays an important role in wave propagating among cardiac tissue, while the heart beating can be terminated when the target wave is broken into turbulent states by electromagnetic radiation. In this investigation, local periodical forcing is applied on the media to induce continuous target wave in the improved cardiac model, which the effect of electromagnetic induction is considered by using magnetic flux, then external electromagnetic radiation is imposed on the media. It is found that target wave propagation can be blocked to stand in a local area and the excitability of media is suppressed to approach quiescent but homogeneous state when electromagnetic radiation is imposed on the media. The sampled time series for membrane potentials decrease to quiescent state due to the electromagnetic radiation. It could accounts for the mechanism of abnormality in heart failure exposed to continuous electromagnetic field.
Bradycardia from flash stimulation.
Einspenner, Michael; Brunet, Donald G; Boissé Lomax, Lysa; Spiller, Allison E
2015-12-01
This case study documents a patient who experienced bradycardia brought on by flash stimulation during a routine outpatient EEG recording. The patient had known photosensitive seizures in the past. During this routine EEG, the patient's heart rate dropped to about 12 beats per minute with the EEG displaying slow-delta-frequency waves with no epileptiform spikes or sharp waves. During immediate follow-up, in our emergency department, the patient had a brief asystolic event, followed by bradycardia. Cardiology examinations were normal. We propose that this response was a photic-triggered reflex vasovagal reaction.
A Local Probe for Universal Non-equilibrium Dynamics
2015-06-01
left in the ground 1T. E. Drake, Y . Sagi, R. Paudel, J. T. Stewart, J. P . Gaebler, and D. S. Jin, “ Direct observation of the fermi surface in an...bottom) allow to switch the laser fast and fine-tune the frequency. “λ/2” refers to half-wave plates, “λ/4” refers to quarter-wave plates, and all cubes...the beat note signal on a fast photodiode. state (|F = 9/2,mF = −7/2〉), any place where excitation light exists. Imaging atoms occurs on a cycling
Role of calmodulin and calcineurin in regulating flagellar motility and wave polarity in Leishmania.
Mukhopadhyay, Aakash Gautam; Dey, Chinmoy Sankar
2017-11-01
We have previously reported the involvement of cyclic AMP in regulating flagellar waveforms in Leishmania. Here, we investigated the roles of calcium, calmodulin, and calcineurin in flagellar motility regulation in L. donovani. Using high-speed videomicroscopy, we show that calcium-independent calmodulin and calcineurin activity is necessary for motility in Leishmania. Inhibition of calmodulin and calcineurin induced ciliary beats interrupting flagellar beating in both live (in vivo) and ATP-reactivated (in vitro) parasites. Our results indicate that signaling mediated by calmodulin and calcineurin operates antagonistically to cAMP signaling in regulating the waveforms of Leishmania flagellum. These two pathways are possibly involved in maintaining the balance between the two waveforms, essential for responding to environmental cues, survival, and infectivity.
Flagellar Kinematics and Swimming of Algal Cells in Viscoelastic Fluids
Qin, B.; Gopinath, A.; Yang, J.; Gollub, J. P.; Arratia, P. E.
2015-01-01
The motility of microorganisms is influenced greatly by their hydrodynamic interactions with the fluidic environment they inhabit. We show by direct experimental observation of the bi-flagellated alga Chlamydomonas reinhardtii that fluid elasticity and viscosity strongly influence the beating pattern - the gait - and thereby control the propulsion speed. The beating frequency and the wave speed characterizing the cyclical bending are both enhanced by fluid elasticity. Despite these enhancements, the net swimming speed of the alga is hindered for fluids that are sufficiently elastic. The origin of this complex response lies in the interplay between the elasticity-induced changes in the spatial and temporal aspects of the flagellar cycle and the buildup and subsequent relaxation of elastic stresses during the power and recovery strokes. PMID:25778677
Dynamic cycling in atrial size and flow during obstructive apnoea
Pressman, Gregg S; Cepeda-Valery, Beatriz; Codolosa, Nicolas; Orban, Marek; Samuel, Solomon P; Somers, Virend K
2016-01-01
Objective Obstructive sleep apnoea (OSA) is strongly associated with cardiovascular disease. However, acute cardiovascular effects of repetitive airway obstruction are poorly understood. While past research used a sustained Mueller manoeuver to simulate OSA we employed a series of gasping efforts to better simulate true obstructive apnoeas. This report describes acute changes in cardiac anatomy and flow related to sudden changes in intrathoracic pressure. Methods and results 26 healthy, normal weight participants performed 5–6 gasping efforts (target intrathoracic pressure −40 mm Hg) while undergoing Doppler echocardiography. 14 participants had sufficient echocardiographic images to allow comparison of atrial areas during the manoeuver with baseline measurements. Mitral and tricuspid E-wave and A-wave velocities postmanoeuver were compared with baseline in all participants. Average atrial areas changed little during the manoeuver, but variance in both atrial areas was significantly greater than baseline. Further, an inverse relationship was noted with left atrial collapse and right atrial enlargement at onset of inspiratory effort. Significant inverse changes were noted in Doppler flow when comparing the first beat postmanoeuver (pMM1) with baseline. Mitral E-wave velocity increased 9.1 cm/s while tricuspid E-wave velocity decreased 7.0 cm/s; by the eighth beat postmanoeuver (pMM8) values were not different from baseline. Mitral and tricuspid A-wave velocities were not different from baseline at pMM1, but both were significantly higher by pMM8. Conclusions Repetitive obstructive apnoeas produce dynamic, inverse changes in atrial size and Doppler flow across the atrioventricular valves. These observations have important implications for understanding the pathophysiology of OSA. PMID:27127636
Calomeni, Mauricio Rocha; Furtado da Silva, Vernon; Velasques, Bruna Brandão; Feijó, Olavo Guimarães; Bittencourt, Juliana Marques; Ribeiro de Souza e Silva, Alair Pedro
2017-01-01
Introduction: One of the positive effects of brain stimulation is interhemispheric modulation as shown in some scientific studies. This study examined if a type of noninvasive stimulation using binaural beats with led-lights and sound would show different modulatory effects upon Alfa and SMR brain waves of elderlies and children with some disease types. Subjects: The sample included 75 individuals of both genders, being, randomly, divided in 6 groups. Groups were named elderly without dementia diagnosis (EWD), n=15, 76±8 years, elderly diagnosed with Parkinson’s disease (EDP), n=15, 72±7 years, elderly diagnosed with Alzheimer’s disease (EDA), n=15, 81±6 years. The other groups were named children with Autism (CA), n=10, 11±4 years, children with Intellectual Impairment (CII), n=10, 12 ±5 years and children with normal cognitive development (CND), n=10, 11±4 years. Instruments and procedure: Instruments were the Mini Mental State Examination Test (MMSE), EEG-Neurocomputer instrument for brain waves registration, brain stimulator, Digit Span Test and a Protocol for working memory training. Data collection followed a pre and post-conjugated stimulation version. Results: The results of the inferential statistics showed that the stimulation protocol had different effects on Alpha and SMR brain waves of the patients. Also, indicated gains in memory functions, for both, children and elderlies as related to gains in brain waves modulation. Conclusion: The results may receive and provide support to a range of studies examining brain modulation and synaptic plasticity. Also, it was emphasized in the results discussion that there was the possibility of the technique serving as an accessory instrument to alternative brain therapies. PMID:29238390
Calomeni, Mauricio Rocha; Furtado da Silva, Vernon; Velasques, Bruna Brandão; Feijó, Olavo Guimarães; Bittencourt, Juliana Marques; Ribeiro de Souza E Silva, Alair Pedro
2017-01-01
One of the positive effects of brain stimulation is interhemispheric modulation as shown in some scientific studies. This study examined if a type of noninvasive stimulation using binaural beats with led-lights and sound would show different modulatory effects upon Alfa and SMR brain waves of elderlies and children with some disease types. The sample included 75 individuals of both genders, being, randomly, divided in 6 groups. Groups were named elderly without dementia diagnosis (EWD), n=15, 76±8 years, elderly diagnosed with Parkinson's disease (EDP), n=15, 72±7 years, elderly diagnosed with Alzheimer's disease (EDA), n=15, 81±6 years. The other groups were named children with Autism (CA), n=10, 11±4 years, children with Intellectual Impairment (CII), n=10, 12 ±5 years and children with normal cognitive development (CND), n=10, 11±4 years. Instruments were the Mini Mental State Examination Test (MMSE), EEG-Neurocomputer instrument for brain waves registration, brain stimulator, Digit Span Test and a Protocol for working memory training. Data collection followed a pre and post-conjugated stimulation version. The results of the inferential statistics showed that the stimulation protocol had different effects on Alpha and SMR brain waves of the patients. Also, indicated gains in memory functions, for both, children and elderlies as related to gains in brain waves modulation. The results may receive and provide support to a range of studies examining brain modulation and synaptic plasticity. Also, it was emphasized in the results discussion that there was the possibility of the technique serving as an accessory instrument to alternative brain therapies.
Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time.
Xiang, Haiyan; Liu, Yanyong; Li, Yinhua; Qin, Yufei; Yu, Mengsun
2012-02-01
To propose a novel noninvasive beat-to-beat arterial blood pressure measurement method based on the Korotkoff sound delay time (KDT) and evaluate its accuracy in preliminary experiments. KDT decreases as the cuff pressure P deflates, which can be described by a function KDT=f (P). Actually, KDT is a function of arterial transmural pressure. Therefore, the variation in blood pressure can be obtained by the transmural pressure, which is estimated by the KDT. Holding the cuff pressure at an approximate constant pressure between systolic pressure and diastolic pressure, the variation in blood pressure ΔEBP between successive heartbeats can be estimated according to KDT and f'(p), which represents the variation of KDT corresponding to unit pressure. Then the blood pressure for each heartbeat can be obtained by accumulating the ΔEBP. Invasive and noninvasive blood pressure values of six participants were measured simultaneously to evaluate the method. The average of the correlation coefficients between the invasive mean arterial pressure (MAP) and the KDT for six participants was -0.91. The average of the correlation coefficients between the invasive MAP and the estimated mean blood pressure (EBP) was 0.92. The mean difference between EBP and MAP was 0.51 mmHg, and the SD was 2.65 mmHg. The mean blood pressure estimated by the KDT is consistent with the invasive MAP. The beat-to-beat blood pressure estimated by KDT provides an accurate estimate of MAP in the preliminary experiments and represents a potential acceptable alternative to invasive blood pressure monitoring during laboratory studies.
Xiao, Hanguang; Tan, Isabella; Butlin, Mark; Li, Decai; Avolio, Alberto P
2018-03-01
Arterial wave reflection has been shown to have a significant dependence on heart rate (HR). However, the underlying mechanisms inherent in the HR dependency of wave reflection have not been well established. This study aimed to investigate the potential mechanisms and role of arterial viscoelasticity using a 55-segment transmission line model of the human arterial tree combined with a fractional viscoelastic model. At varying degrees of viscoelasticity modeled as fractional order parameter α, reflection magnitude (RM), reflection index (RI), augmentation index (AIx), and a proposed novel normalized reflection coefficient (Γ norm ) were estimated at different HRs from 60 to 100 beats/min with a constant mean flow of 70 ml/s. RM, RI, AIx, and Γ norm at the ascending aorta decreased linearly with increasing HR at all degrees of viscoelasticity. The means ± SD of the HR dependencies of RM, RI, AIx, and Γ norm were -0.042 ± 0.004, -0.018 ± 0.001, -1.93 ± 0.55%, and -0.037 ± 0.002 per 10 beats/min, respectively. There was a significant and nonlinear reduction in RM, RI, and Γ norm with increasing α at all HRs. In addition, HR and α have a more pronounced effect on wave reflection at the aorta than at peripheral arteries. The potential mechanism of the HR dependency of wave reflection was explained by the inverse dependency of the reflection coefficient on frequency, with the harmonics of the pulse waveform moving toward higher frequencies with increasing HR. This HR dependency can be modulated by arterial viscoelasticity. NEW & NOTEWORTHY This in silico study addressed the underlying mechanisms of how heart rate influences arterial wave reflection based on a transmission line model and elucidated the role of arterial viscoelasticity in the dependency of arterial wave reflection on heart rate. This study provides insights into wave reflection as a frequency-dependent phenomenon and demonstrates the validity of using reflection magnitude and reflection index as wave reflection indexes.
Lindberg, S; Cervin, A; Runer, T; Thomasson, L
1996-09-01
Investigations of mucociliary activity in vivo are based on photoelectric recordings of light reflections from the mucosa. The alterations in light intensity produced by the beating cilia are picked up by a photodetector and converted to photoelectric signals. The optimal processing of these signals is not known, but in vitro recordings have been reported to benefit from fast Fourier transformation (FFT) of the signal. The aim of the investigation was to study the effect of FFT for frequency analysis of photoelectric signals originating from an artificial light source simulating mucociliary activity or from sinus or nasal mucosa in vivo, as compared to a conventional method of calculating mucociliary wave frequency, in which each peak in the signal is interpreted as a beat (old method). In the experiments with the artificial light source, the FFT system was superior to the conventional method by a factor of 50 in detecting weak signals. By using FFT signal processing, frequency could be correctly calculated in experiments with a compound signal. In experiments in the rabbit maxillary sinus, the spontaneous variations were greater when signals were processed by FFT. The correlation between the two methods was excellent: r = .92. The increase in mucociliary activity in response to the ciliary stimulant methacholine at a dosage of 0.5 microgram/kg was greater measured with the FFT than with the old method (55.3% +/- 8.3% versus 43.0% +/- 8.2%, p < .05, N = 8), and only with the FFT system could a significant effect of a threshold dose (0.05 microgram/kg) of methacholine be detected. In the human nose, recordings from aluminum foil placed on the nasal dorsum and from the nasal septa mucosa displayed some similarities in the lower frequency spectrum (< 5 Hz) attributable to artifacts. The predominant cause of these artifacts was the pulse beat, whereas in the frequency spectrum above 5 Hz, results differed for the two sources of reflected light, the mean frequency in seven healthy volunteers being 7.8 +/- 1.6 Hz for the human nasal mucosa. It is concluded that the FFT system has greater sensitivity in detecting photoelectric signals derived from the mucociliary system, and that it is also a useful tool for analyzing the contributions of artifacts to the signal.
A model for the generation of two-dimensional surf beat
List, Jeffrey H.
1992-01-01
A finite difference model predicting group-forced long waves in the nearshore is constructed with two interacting parts: an incident wave model providing time-varying radiation stress gradients across the nearshore, and a long-wave model which solves the equations of motion for the forcing imposed by the incident waves. Both shallow water group-bound long waves and long waves generated by a time-varying breakpoint are simulated. Model-generated time series are used to calculate the cross correlation between wave groups and long waves through the surf zone. The cross-correlation signal first observed by Tucker (1950) is well predicted. For the first time, this signal is decomposed into the contributions from the two mechanisms of leaky mode forcing. Results show that the cross-correlation signal can be explained by bound long waves which are amplified, though strongly modified, through the surf zone before reflection from the shoreline. The breakpoint-forced long waves are added to the bound long waves at a phase of pi/2 and are a secondary contribution owing to their relatively small size.
Controlling of the electromagnetic solitary waves generation in the wake of a two-color laser
NASA Astrophysics Data System (ADS)
Pan, K. Q.; Li, S. W.; Guo, L.; Yang, D.; Li, Z. C.; Zheng, C. Y.; Jiang, S. E.; Zhang, B. H.; He, X. T.
2018-05-01
Electromagnetic solitary waves generated by a two-color laser interaction with an underdense plasma are investigated. It is shown that, when the former wave packet of the two-color laser is intense enough, it will excite nonlinear wakefields and generate electron density cavities. The latter wave packets will beat with the nonlinear wakefield and generate both high-frequency and low-frequency components. When the peak density of the cavities exceeds the critical density of the low-frequency component, this part of the electromagnetic field will be trapped to generate electromagnetic solitary waves. By changing the laser and plasma parameters, we can control the wakefield generation, which will also control the generation of the solitary waves. One-dimensional particle-in-cell simulations are performed to prove the controlling of the solitary waves. The simulation results also show that solitary waves generated by higher laser intensities will become moving solitary waves. The two-dimensional particle-in-cell also shows the generation of the solitary waves. In the two-dimensional case, solitary waves are distributed in the transverse directions because of the filamentation instability.
Differential diagnosis of cardiovascular diseases and T-wave alternans
NASA Astrophysics Data System (ADS)
Ramasamy, Mouli; Varadan, Vijay K.
2016-04-01
T wave alternans (TWA) is the variation of the T-wave in electrocardiogram that is observed between periodic beats. TWA is one of the important precursors used to diagnose sudden cardiac death (SCD). Several clinical studies have tried to determine the significance of using TWA analysis to detect abnormalities that may lead to Ventricular Arrhythmias, as well as establish metrics to perform risk stratification for cardiovascular patients with prior cardiac episodes. The statistical significance of TWA in predicting ventricular arrhythmias has been established in patients across several diagnoses. Studies have also shown the significance of the predictive value of TWA analysis in post myocardial infarction patients, risk of SCD, congestive heart failure, ischemic cardiomyopathy, and Chagas disease.
Koivikko, Minna L; Kenttä, Tuomas; Salmela, Pasi I; Huikuri, Heikki V; Perkiömäki, Juha S
2017-03-01
Experimental studies have revealed that hypoglycaemia can result in morphological changes in electrocardiographic repolarisation in subjects with type 1 diabetes. However, the influence of spontaneous nocturnal hypoglycaemia on repolarisation morphology in a 'real life' situation is not clear. Adults with type 1 diabetes (n = 11) underwent continuous glucose monitoring with a subcutaneous sensor and digital 12-lead ECG recording for three nights. T-wave morphology was analysed with custom-made software during both hypoglycaemia (glucose <3.5 mmol/l at least 20 min) from ten consecutive heart beats in the middle of the deepest hypoglycaemia and from a control nonhypoglycaemic period (glucose ≥5.0 mmol/l) from the same recording. In the comparison of 10 hypoglycaemia-control pairs, heart rate (65 ± 12 beats/min during normoglycaemia versus 85 ± 19 beats/min during hypoglycaemia, p = 0.028) increased and the QT c interval (439 ± 5 vs. 373 ± 5 ms, respectively, p = 0.025) decreased significantly during hypoglycaemia. The spatial QRS-T angle (TCRT) was reduced, and the roughness of the T-wave loop (T-E) increased significantly (p = 0.037 for both) in the patients during hypoglycaemia. In adults with type 1 diabetes, spontaneous nocturnal hypoglycaemia results in morphological changes and increased heterogeneity of global cardiac repolarisation. These changes may contribute to the risk of 'dead in bed' syndrome encountered in young individuals with type 1 diabetes.
"A Symphony of Possibilities": The Joy of Art and Writing through "The Beat Within"
ERIC Educational Resources Information Center
Arthur, Deborah Smith
2017-01-01
"The Beat Within" is a writing and art program and publication based in San Francisco that gives a voice to incarcerated youth in various locations across the country. This article recounts the experience of the partnership between a community-based learning course at Portland State University and juvenile detention in Multnomah County,…
Asymmetrically localized proteins stabilize basal bodies against ciliary beating forces
Galati, Domenico F.
2016-01-01
Basal bodies are radially symmetric, microtubule-rich structures that nucleate and anchor motile cilia. Ciliary beating produces asymmetric mechanical forces that are resisted by basal bodies. To resist these forces, distinct regions within the basal body ultrastructure and the microtubules themselves must be stable. However, the molecular components that stabilize basal bodies remain poorly defined. Here, we determine that Fop1 functionally interacts with the established basal body stability components Bld10 and Poc1. We find that Fop1 and microtubule glutamylation incorporate into basal bodies at distinct stages of assembly, culminating in their asymmetric enrichment at specific triplet microtubule regions that are predicted to experience the greatest mechanical force from ciliary beating. Both Fop1 and microtubule glutamylation are required to stabilize basal bodies against ciliary beating forces. Our studies reveal that microtubule glutamylation and Bld10, Poc1, and Fop1 stabilize basal bodies against the forces produced by ciliary beating via distinct yet interdependent mechanisms. PMID:27807131
Multiheterodyne spectroscopy using interband cascade lasers
NASA Astrophysics Data System (ADS)
Sterczewski, Lukasz A.; Westberg, Jonas; Patrick, Charles Link; Kim, Chul Soo; Kim, Mijin; Canedy, Chadwick L.; Bewley, William W.; Merritt, Charles D.; Vurgaftman, Igor; Meyer, Jerry R.; Wysocki, Gerard
2018-01-01
While midinfrared radiation can be used to identify and quantify numerous chemical species, contemporary broadband midinfrared spectroscopic systems are often hindered by large footprints, moving parts, and high power consumption. In this work, we demonstrate multiheterodyne spectroscopy (MHS) using interband cascade lasers, which combines broadband spectral coverage with high spectral resolution and energy-efficient operation. The lasers generate up to 30 mW of continuous-wave optical power while consuming <0.5 W of electrical power. A computational phase and timing correction algorithm is used to obtain kHz linewidths of the multiheterodyne beat notes and up to 30 dB improvement in signal-to-noise ratio. The versatility of the multiheterodyne technique is demonstrated by performing both rapidly swept absorption and dispersion spectroscopic assessments of low-pressure ethylene (C2H4) acquired by extracting a single beat note from the multiheterodyne signal, as well as broadband MHS of methane (CH4) acquired with all available beat notes with microsecond temporal resolution and an instantaneous optical bandwidth of ˜240 GHz. The technology shows excellent potential for portable and high-resolution solid-state spectroscopic chemical sensors operating in the midinfrared.
Estimation of 3-D conduction velocity vector fields from cardiac mapping data.
Barnette, A R; Bayly, P V; Zhang, S; Walcott, G P; Ideker, R E; Smith, W M
2000-08-01
A method to estimate three-dimensional (3-D) conduction velocity vector fields in cardiac tissue is presented. The speed and direction of propagation are found from polynomial "surfaces" fitted to space-time (x, y, z, t) coordinates of cardiac activity. The technique is applied to sinus rhythm and paced rhythm mapped with plunge needles at 396-466 sites in the canine myocardium. The method was validated on simulated 3-D plane and spherical waves. For simulated data, conduction velocities were estimated with an accuracy of 1%-2%. In experimental data, estimates of conduction speeds during paced rhythm were slower than those found during normal sinus rhythm. Vector directions were also found to differ between different types of beats. The technique was able to distinguish between premature ventricular contractions and sinus beats and between sinus and paced beats. The proposed approach to computing velocity vector fields provides an automated, physiological, and quantitative description of local electrical activity in 3-D tissue. This method may provide insight into abnormal conduction associated with fatal ventricular arrhythmias.
Second-harmonic generation of a dual-frequency laser in a MgO:PPLN crystal.
Kang, Ying; Yang, Suhui; Brunel, Marc; Cheng, Lijun; Zhao, Changming; Zhang, Haiyang
2017-04-10
A dual-frequency CW laser at a wavelength of 1.064 μm is frequency doubled in a MgO:PPLN nonlinear crystal. The fundamental dual-frequency laser has a tunable beat note from 125 MHz to 175 MHz. A laser-diode pumped fiber amplifier is used to amplify the dual-frequency fundamental output to a maximum power of 50 W before frequency doubling. The maximum output power of the green light is 1.75 W when the input fundamental power is 12 W, corresponding to a frequency doubling efficiency of 14.6%. After frequency doubling, green light with modulation frequencies in two bands from 125 MHz to 175 MHz and from 250 MHz to 350 MHz is achieved simultaneously. The relative intensities of the beat notes at the two bands can be adjusted by changing the relative intensities at different frequencies of the fundamental light. The spectral width and frequency stabilities of the beat notes in fundamental wave and green light are also measured, respectively. The modulated green light has potential applications in underwater ranging, communication, and imaging.
Two-tone nonlinear electrostatic waves in the quantum electron–hole plasma of semiconductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dubinov, A. E., E-mail: dubinov-ae@yandex.ru; Kitayev, I. N.
2017-01-15
Longitudinal electrostatic waves in the quantum electron–hole plasma of semiconductors are considered taking into account the degeneracy of electrons and holes and the exchange interaction. It is found in the framework of linear theory that the dispersion curve of longitudinal waves has two branches: plasmon and acoustic. An expression for the critical cutoff frequency for plasma oscillations and an expression for the speed of sound for acoustic vibrations are derived. It is shown that the plasma wave always exists in the form of a superposition of two components, characterized by different periods and wavelengths. Two nonlinear solutions are obtained withinmore » nonlinear theory: one in the form of a simple superposition of two tones and the other in the form of beats.« less
Development of a wearable system module for monitoring physical and mental workload.
Kim, Sinbae; Nakamura, Hiromi; Yoshida, Toshihiko; Kishimoto, Masamichi; Imai, Yohsuke; Matsuki, Noriaki; Ishikawa, Takuji; Yamaguchi, Takami
2008-11-01
The population of most developed countries is rapidly aging, which has created a growing demand for home care. A key issue in medicine is supporting the increasing number of elderly patients, both physically and mentally. In this study, we developed a wearable computer that contained modules for measuring electrocardiograms (ECGs) and femoral artery pulse waves using an accelerometer. This system has several benefits: (a) it can provide a database server in each patient's home; (b) its high extendibility and flexibility facilitate adaptation to a patient's needs; and (c) it allows patients to keep their own data, thus protecting the privacy of personal information. To clarify the capabilities and reliability of the system, we applied it to 8 healthy young volunteers during states of physical and mental work. This system successfully detected clear ECGs and femoral artery pulse waves to calculate important bioinformation, including heart rate, pulse wave velocity, and the power spectral density of spontaneous beat-to-beat oscillations in the R-R interval. In this study, we proposed the way to provide an assessment of the physical and mental condition of the subject using analysis of the bio-information with respect to the physical and mental workloads. The present study provides useful knowledge for the development of a wearable computer designed to monitor the physical and mental conditions of older persons and patients.
Justification of Wife Beating in Adolescents: Associated Beliefs and Behaviors.
Devenish, Bethany; Hooley, Merrilyn; Mellor, David
2018-04-01
Socioeconomically disadvantaged adolescents who are exposed to social norms related to violence against women are more likely to experience or be perpetrators of intimate partner violence. This study evaluated factors hypothesized to be associated with acceptance of wife beating among 240 male and female adolescents aged 10-16 years participating in a World Vision program in Armenia. Acceptance of wife beating was associated with relational victimization, perceived social support, and parent and community boundaries and expectations, but was not associated with overt victimization or aggression. These findings highlight several areas that may be important for violence prevention research.
A binaural beat constructed from a noise
Akeroyd, Michael A
2012-01-01
The binaural beat has been used for over one hundred years as a stimulus for generating the percept of motion. Classically the beat consists of a pure tone at one ear (e.g. 500 Hz) and the same pure tone at the other ear but shifted upwards or downwards in frequency (e.g., 501 Hz). An experiment and binaural computational analysis are reported which demonstrate that a more powerful motion percept can be obtained by applying the concept of the frequency shift to a noise, via an upwards or downwards shift in the frequency of the Fourier components of its spectrum. PMID:21218863
Effects of acute hyperthermia on the carotid baroreflex control of heart rate in humans
NASA Astrophysics Data System (ADS)
Yamazaki, F.; Sagawa, S.; Torii, R.; Endo, Y.; Shiraki, K.
The purpose of this study was to examine the effect of hyperthermia on the carotid baroreceptor-cardiac reflexes in humans. Nine healthy males underwent acute hyperthermia (esophageal temperature 38.0° C) produced by hot water-perfused suits. Beat-to-beat heart rate (HR) responses were determined during positive and negative R-wave-triggered neck pressure steps from +40 to -65 mm Hg during normothermia and hyperthermia. The carotid baroreceptor-cardiac reflex sensitivity was evaluated from the maximum slope of the HR response to changes in carotid distending pressure. Buffering capacity of the HR response to carotid distending pressure was evaluated in % from a reference point calculated as (HR at 0 mm Hg neck pressure-minimum HR)/HR range ×100. An upward shift of the curve was evident in hyperthermia because HR increased from 57.7+/-2.4 beats/min in normothermia to 88.7+/-4.1 beats/min in hyperthermia (P<0.05) without changes in mean arterial pressure. The maximum slope of the curve in hyperthermia was similar to that in normothermia. The reference point was increased (P<0.05) during hyperthermia. These results suggest that the sensitivity of the carotid baroreflex of HR remains unchanged in hyperthermia. However, the capacity for tachycardia response to rapid onset of hypotension is reduced and the capacity for bradycardia response to sudden hypertension is increased during acute hyperthermia.
Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals.
Jeyhani, Vala; Mahdiani, Shadi; Peltokangas, Mikko; Vehkaoja, Antti
2015-01-01
Heart rate variability (HRV) has become a useful tool in analysis of cardiovascular system in both research and clinical fields. HRV has been also used in other applications such as stress level estimation in wearable devices. HRV is normally obtained from ECG as the time interval of two successive R waves. Recently PPG has been proposed as an alternative for ECG in HRV analysis to overcome some difficulties in measurement of ECG. In addition, PPG-HRV is also used in some commercial devices such as modern optical wrist-worn heart rate monitors. However, some researches have shown that PPG is not a surrogate for heart rate variability analysis. In this work, HRV analysis was applied on beat-to-beat intervals obtained from ECG and PPG in 19 healthy male subjects. Some important HRV parameters were calculated from PPG-HRV and ECG-HRV. Maximum of PPG and its second derivative were considered as two methods for obtaining the beat-to-beat signals from PPG and the results were compared with those achieved from ECG-HRV. Our results show that the smallest error happens in SDNN and SD2 with relative error of 2.46% and 2%, respectively. The most affected parameter is pNN50 with relative error of 29.89%. In addition, in our trial, using the maximum of PPG gave better results than its second derivative.
NASA Astrophysics Data System (ADS)
Kumar, Pawan; Parmananda, P.
2018-04-01
Experiments involving the Mercury Beating Heart (MBH) oscillator, exhibiting irregular (aperiodic) dynamics, are performed. In the first set of experiments, control over irregular dynamics of the MBH oscillator was obtained via a superimposed periodic voltage signal. These irregular (aperiodic) dynamics were recovered once the control was switched off. Subsequently, two MBH oscillators were coupled to attain synchronization of their aperiodic oscillations. Finally, two uncoupled MBH oscillators were subjected, repeatedly, to a common stochastic forcing, resulting in an enhancement of their mutual phase correlation.
Wahbeh, Helané; Calabrese, Carlo; Zwickey, Heather; Zajdel, Dan
2007-03-01
When two auditory stimuli of different frequency are presented to each ear, binaural beats are perceived by the listener. The binaural beat frequency is equal to the difference between the frequencies applied to each ear. Our primary objective was to assess whether steady-state entrainment of electroencephalographic activity to the binaural beat occurs when exposed to a specific binaural beat frequency as has been hypothesized. Our secondary objective was to gather preliminary data on neuropsychologic and physiologic effects of binaural beat technology. A randomized, blinded, placebo-controlled crossover experiment in 4 healthy adult subjects. Subjects were randomized to experimental auditory stimulus of 30 minutes of binaural beat at 7 Hz (carrier frequencies: 133 Hz L; 140 Hz R) with an overlay of pink noise resembling the sound of rain on one session and control stimuli of the same overlay without the binaural beat carrier frequencies on the other session. Data were collected during two separate sessions 1 week apart. Neuropsychologic and blood pressure data were collected before and after the intervention; electroencephalographic data were collected before, during, and after listening to either binaural beats or control. Neuropsychologic measures included State Trait Anxiety Inventory, Profile of Mood States, Rey Auditory Verbal List Test, Stroop Test, and Controlled Oral Word Association Test. Spectral and coherence analysis was performed on the electroencephalogram (EEG), and all measures were analyzed for changes between sessions with and without binaural beat stimuli. There were no significant differences between the experimental and control conditions in any of the EEG measures. There was an increase of the Profile of Mood States depression subscale in the experimental condition relative to the control condition (p = 0.02). There was also a significant decrease in immediate verbal memory recall (p = 0.03) in the experimental condition compared to control condition. We did not find support for steady-state entrainment of the scalp-recorded EEG while listening to 7-Hz binaural beats. Although our data indicated increased depression and poorer immediate recall after listening to binaural beats, larger studies are needed to confirm these findings.
NASA Astrophysics Data System (ADS)
Paik, Seoyoung; Lee, Sang-Yun; McCamey, Dane R.; Boehme, Christoph
2011-12-01
Electrically detected spin-Rabi beat oscillation of pairs of paramagnetic near interface states at the phosphorous doped (1016 cm-3) Si(111)/SiO2 interface is reported. Due to the g-factor anisotropy of the Pb center (a silicon surface dangling bond), one can tune intrapair Larmor frequency differences (Larmor separations) by orientation of the crystal with regard to an external magnetic field. Since Larmor separation governs the number of beating spin pairs, crystal orientation can control the beat current. This is used to identify spin states that are paired by mutual electronic transitions. The experiments confirm the presence of the previously reported 31P-Pb transition and provide direct experimental evidence of the previously hypothesized Pb-E' center (a near interface SiO2 bulk state) transition.
NASA Astrophysics Data System (ADS)
Zhang, Z. X.; Wang, L. Z.; Jin, Z. J.; Zhang, Q.; Li, X. L.
2013-08-01
The efficient identification of the unbalanced responses in the inner and outer rotors from the beat vibration is the key step in the dynamic balancing of a dual-rotor system with a slight rotating speed difference. This paper proposes a non-whole beat correlation method to identify the unbalance responses whose integral time is shorter than the whole beat correlation method. The principle, algorithm and parameter selection of the proposed method is emphatically demonstrated in this paper. From the numerical simulation and balancing experiment conducted on horizontal decanter centrifuge, conclusions can be drawn that the proposed approach is feasible and practicable. This method makes important sense in developing the field balancing equipment based on portable Single Chip Microcomputer (SCMC) with low expense.
Yamakawa, Keisuke Kobayashi; Shimojo, Hirofumi; Takagi, Hideki; Tsubakimoto, Shozo; Sengoku, Yasuo
2017-10-01
We investigated the effects of synchronizing kick frequency with the beat of a metronome on kinematic and electromyographic (EMG) parameters during the underwater dolphin kick as a pilot study related to the research that entitled " Effect of increased kick frequency on propelling efficiency and muscular co-activation during underwater dolphin kick" (Yamakawa et al., 2017) [1]. Seven collegiate female swimmers participated in this experiment. The participants conducted two underwater dolphin kick trials: swimming freely at maximum effort, and swimming while synchronizing the kick frequency of maximum effort with the beat of a metronome. The kinematic parameters during the underwater dolphin kick were calculated by 2-D motion analysis, and surface electromyographic measurements were taken from six muscles (rectus abdominis, erector spinae, rectus femoris, biceps femoris, tibialis anterior, and gastrocnemius). The results revealed no significant differences in the kinematic and EMG parameters between trials of the two swimming techniques. Therefore, the action of synchronizing the kick frequency with the beat of a metronome did not affect movement or muscle activity during the underwater dolphin kick in this experiment.
Jejeebhoy, S J
1998-09-01
This report examines the linkages between wife-beating and one health-related consequence for women, their experience of fetal and infant mortality. Community-based data are used drawn from women surveyed in two culturally distinct sites of rural India: Uttar Pradesh in the north, in which gender relations are highly stratified, and Tamil Nadu in the south, in which they are more egalitarian. Results suggest that wife-beating is deeply entrenched, that attitudes uniformly justify wife-beating, and that few women can escape an abusive marriage. They also suggest that the health consequences of domestic violence--in terms of pregnancy loss and infant mortality--are considerable and that Indian women's experience of infant and fetal mortality is powerfully conditioned by the strength of the patriarchal social system. Results are tentative because of data limitations, but they are consistent and strong enough to warrant concern. They argue for the integration of services to identify, refer, and prevent domestic violence in the primary or reproductive health programs of the country and for the safe motherhood programs to be particularly vigilant, sensitive, and responsive to the conditions of battered women during pregnancy and the postpartum period.
Wearable PWV technologies to measure Blood Pressure: eliminating brachial cuffs.
Solá, J; Proença, M; Chételat, O
2013-01-01
The clinical demand for technologies to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is strong: new generation of BP monitors are expected to be not only accurate, but also non-occlusive. In this paper we review recent advances on the use of the so-called Pulse Wave Velocity (PWV) technologies to estimate BP in a beat-by-beat basis. After introducing the working principle and underlying methodological limitations, two implementation examples are provided. Pilot studies have demonstrated that novel PWV-based BP monitors depict accuracy scores falling within the limits of the British Hypertensive Society (BHS) Grade A standard. The reported techniques pave the way towards ambulatory-compliant, continuous and non-occlusive BP monitoring devices, where the use of inflation cuffs is drastically reduced.
A FBG pulse wave demodulation method based on PCF modal interference filter
NASA Astrophysics Data System (ADS)
Zhang, Cheng; Xu, Shan; Shen, Ziqi; Zhao, Junfa; Miao, Changyun; Bai, Hua
2016-10-01
Fiber optic sensor embedded in textiles has been a new direction of researching smart wearable technology. Pulse signal which is generated by heart beat contains vast amounts of physio-pathological information about the cardiovascular system. Therefore, the research for textile-based fiber optic sensor which can detect pulse wave has far-reaching effects on early discovery and timely treatment of cardiovascular diseases. A novel wavelength demodulation method based on photonic crystal fiber (PCF) modal interference filter is proposed for the purpose of developing FBG pulse wave sensing system embedded in smart clothing. The mechanism of the PCF modal interference and the principle of wavelength demodulation based on In-line Mach-Zehnder interferometer (In-line MZI) are analyzed in theory. The fabricated PCF modal interferometer has the advantages of good repeatability and low temperature sensitivity of 3.5pm/°C from 25°C to 60°C. The designed demodulation system can achieve linear demodulation in the range of 2nm, with the wavelength resolution of 2.2pm and the wavelength sensitivity of 0.055nm-1. The actual experiments' result indicates that the pulse wave can be well detected by this demodulation method, which is in accordance with the commercial demodulation instrument (SM130) and more sensitive than the traditional piezoelectric pulse sensor. This demodulation method provides important references for the research of smart clothing based on fiber grating sensor embedded in textiles and accelerates the developments of wearable fiber optic sensors technology.
Wiggins, Delonia L; Strasburger, Janette F; Gotteiner, Nina L; Cuneo, Bettina; Wakai, Ronald T
2013-08-01
Blocked atrial bigeminy (BAB) and second-degree atrioventricular block with 2:1 conduction block (2:1 AVB) both present as ventricular bradycardia and can be difficult to distinguish by echocardiography. Since the prognosis and clinical management of these rhythms are different, an accurate diagnosis is essential. To identify magnetic and mechanical heart rate and rhythm parameters that could reliably distinguish BAB from 2:1 AVB. A retrospective study of ten BAB and seven 2:1 AVB subjects was performed, using fMCG and pulsed Doppler ultrasound. Distinguishing BAB from 2:1 AVB by using fMCG was relatively straightforward because in BAB the ectopic P wave (P') occurred early, resulting in a bigeminal (short-long) atrial rhythm. The normalized coupling interval of the ectopic beat (PP' of the blocked beat to PP of the conducted beat) was 0.29 ± 0.03. In contrast, the echocardiographic assessment of inflow-outflow gave a normalized mechanical coupling interval (AA'/AA) near 0.5, which made it difficult to distinguish BAB from 2:1 AVB. Heart rate distinguished most subjects with BAB from those with 2:1 AVB (82 ± 5.7 beats/min vs 69 ± 4.2 beats/min), but was not a completely reliable indicator. In most subjects, BAB alternated with sinus rhythm or other rhythms, resulting in complex heart rate and rhythm patterns. Fetal BAB and 2:1 AV block can be difficult to distinguish using echocardiography because in many fetuses with BAB the mechanical rhythm does not accurately reflect the magnetic rhythm. fMCG provides a more reliable means of making a differential diagnosis. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Janusek, D; Kania, M; Zaczek, R; Zavala-Fernandez, H; Maniewski, R
2014-04-01
The presence of T wave alternans (TWA) in the surface ECG signals has been recognized as a marker of electrical instability, and is hypothesized to be related to patients at increased risk for ventricular arrhythmias. In this paper we present a TWA simulation study. The TWA phenomenon was simulated by changing the duration of the ventricular heart cells action potential. The magnitude was calculated in the surface ECG with the use of the time domain method. The spatially concordant TWA, where during one heart beat all ventricular cells display a short-duration action potential and during the next beat they exhibit a long-duration action potential, as well as the discordant TWA, where at least one region is out of phase, was simulated. The vectocardiographic representation was employed. The obtained results showed a high level of T-loop pattern and location disturbances connected to the discordant TWA simulation in contrast to the concordant one. This result may be explained by the spatial heterogeneity of the ventricular repolarization process, which could be higher for the discordant TWA than for the concordant TWA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Dual-frequency continuous wave optical parametric oscillator
NASA Astrophysics Data System (ADS)
Sun, Bingjie; Wang, Xin; Yang, Suhui; Li, Kun
2018-01-01
This article shows a dual-frequency OPO with multi-grating (28.5-31.5 μm) periodically poled MgO:LiNbO3 (MgO:PPLN) pumped by a dual-frequency continuous wave at 1.064 μm. The wavelengths of idler and signal varying versus temperature at different periods of inverted domains were numerical simulated. It proves that as the temperature rises, or as the poling period increases, the idler wavelength shortens and signal wavelength lengthens. The pump is a 30 W dual-frequency fiber laser MOPA with beat note frequency varying from 125 MHz to 175 MHz. The pump threshold of the bow-tie ring cavity OPO was 3 W. An average dual-frequency idler output power of 2.6 W was obtained when the pump power was 17.2 W at 45 °C. The idler wavelength was 3.4 μm when the poling period was 30.5 μm. The idler wavelength could be tuned from 2.9 μm to 3.9 μm by changing the temperature and the poling period, and the beat note frequency was proved to be equal to that of the pump.
Electron Acceleration by Beating of Two Intense Cross-Focused Hollow Gaussian Laser Beams in Plasma
NASA Astrophysics Data System (ADS)
Mahmoud, Saleh T.; Gauniyal, Rakhi; Ahmad, Nafis; Rawat, Priyanka; Purohit, Gunjan
2018-01-01
This paper presents propagation of two cross-focused intense hollow Gaussian laser beams (HGBs) in collisionless plasma and its effect on the generation of electron plasma wave (EPW) and electron acceleration process, when relativistic and ponderomotive nonlinearities are simultaneously operative. Nonlinear differential equations have been set up for beamwidth of laser beams, power of generated EPW, and energy gain by electrons using WKB and paraxial approximations. Numerical simulations have been carried out to investigate the effect of typical laser-plasma parameters on the focusing of laser beams in plasmas and further its effect on power of excited EPW and acceleration of electrons. It is observed that focusing of two laser beams in plasma increases for higher order of hollow Gaussian beams, which significantly enhanced the power of generated EPW and energy gain. The amplitude of EPW and energy gain by electrons is found to enhance with an increase in the intensity of laser beams and plasma density. This study will be useful to plasma beat wave accelerator and in other applications requiring multiple laser beams. Supported by United Arab Emirates University for Financial under Grant No. UPAR (2014)-31S164
A frequency standard via spectrum analysis and direct digital synthesis
NASA Astrophysics Data System (ADS)
Li, Dawei; Shi, Daiting; Hu, Ermeng; Wang, Yigen; Tian, Lu; Zhao, Jianye; Wang, Zhong
2014-11-01
We demonstrated a frequency standard based on a detuned coherent population beating phenomenon. In this phenomenon, the beat frequency of the radio frequency for laser modulation and the hyperfine splitting can be obtained by digital signal processing technology. After analyzing the spectrum of the beat frequency, the fluctuation information is obtained and applied to compensate for the frequency shift to generate the standard frequency by the digital synthesis method. Frequency instability of 2.6 × 1012 at 1000 s is observed in our preliminary experiment. By eliminating the phase-locking loop, the method will enable us to achieve a full-digital frequency standard with remarkable stability.
The effect of gamma-enhancing binaural beats on the control of feature bindings.
Colzato, Lorenza S; Steenbergen, Laura; Sellaro, Roberta
2017-07-01
Binaural beats represent the auditory experience of an oscillating sound that occurs when two sounds with neighboring frequencies are presented to one's left and right ear separately. Binaural beats have been shown to impact information processing via their putative role in increasing neural synchronization. Recent studies of feature-repetition effects demonstrated interactions between perceptual features and action-related features: repeating only some, but not all features of a perception-action episode hinders performance. These partial-repetition (or binding) costs point to the existence of temporary episodic bindings (event files) that are automatically retrieved by repeating at least one of their features. Given that neural synchronization in the gamma band has been associated with visual feature bindings, we investigated whether the impact of binaural beats extends to the top-down control of feature bindings. Healthy adults listened to gamma-frequency (40 Hz) binaural beats or to a constant tone of 340 Hz (control condition) for ten minutes before and during a feature-repetition task. While the size of visuomotor binding costs (indicating the binding of visual and action features) was unaffected by the binaural beats, the size of visual feature binding costs (which refer to the binding between the two visual features) was considerably smaller during gamma-frequency binaural beats exposure than during the control condition. Our results suggest that binaural beats enhance selectivity in updating episodic memory traces and further strengthen the hypothesis that neural activity in the gamma band is critically associated with the control of feature binding.
Nonlinear Electron and Ion Density Modulations Driven by Interfering High-Intensity Laser Pulses
NASA Astrophysics Data System (ADS)
Chen, S.; Zhang, P.; Saleh, N.; Sheng, Z. M.; Widjaja, C.; Umstadter, D.
2002-11-01
The optical spectrum from interaction of two crossed ultra short laser beams (400 fs) with underdense plasma is measured at various angles. Enhancement and broadening of the spectrum in the forward direction of one of the beams shows evidence of energy transfer between the two laser beams(G. Shvets, N. J. Fisch, A. Pukhov, and J. Meyer-ter-Vehn, Phys. Rev. E 60, 2218 (1999).), which is confirmed by a 2-D PIC simulation. The spectrum and scattered power indicate that a large amplitude electron density modulation is driven, which is attributed to the ponderomotive force of the interference, in agreement with simple analysis and simulation(δn/n_0>10). Stokes and anti-Stokes satellites reveals that the energy transfer is accompanied by a large amplitude nonlinear ion acoustic wave created by the laser interference in the strongly driven limit. The wavelength shift indicates that the ion acoustic wave's speed is 2.3×10^6m/s, corresponding to the electron temperature 119 keV, which is attributed to stochastic heating, also found in the simulation. Besides being of interest in basic plasma physics, this research is also relevant to fast igniter fusion or ion acceleration experiments, in which a laser pulse may potentially beat with a reflected weaker pulse, with intensities comparable to those used in the experiment(Y. Sentoku, et al., Appl. Phys. B 74, 207-215 (2002).).
Beating motion of a circular cylinder in vortex-induced vibrations
NASA Astrophysics Data System (ADS)
Shen, Linwei; Chan, Eng-Soon; Wei, Yan
2018-04-01
In this paper, beating phenomenon of a circular cylinder in vortex-induced vibration is studied by numerical simulations in a systematic manner. The cylinder mass coefficients of 2 and 10 are considered, and the Reynolds number is 150. Two distinctive frequencies, namely cylinder oscillation and vortex shedding frequencies, are obtained from the harmonic analysis of the cylinder displacement. The result is consistent with that observed in laboratory experiments. It is found that the cylinder oscillation frequency changes with the natural frequency of the cylinder while the reduced velocity is varied. The added-mass coefficient of the cylinder in beating motion is therefore estimated. Meanwhile, the vortex shedding frequency does not change dramatically in the beating situations. In fact, it is very close to 0.2. Accordingly, the lift force coefficient has two main components associated with these two frequencies. Besides, higher harmonics of the cylinder oscillation frequency appear in the spectrum of the lift coefficient. Moreover, the vortex shedding timing is studied in the beating motion by examining the instantaneous flow fields in the wake, and two scenarios of the vortex formation are observed.
Lin, Eric; Craig, Calvin; Lamothe, Marcel; Sarunic, Marinko V.; Beg, Mirza Faisal
2015-01-01
Zebrafish are increasingly being used as a model of vertebrate cardiology due to mammalian-like cardiac properties in many respects. The size and fecundity of zebrafish make them suitable for large-scale genetic and pharmacological screening. In larger mammalian hearts, optical mapping is often used to investigate the interplay between voltage and calcium dynamics and to investigate their respective roles in arrhythmogenesis. This report outlines the construction of an optical mapping system for use with zebrafish hearts, using the voltage-sensitive dye RH 237 and the calcium indicator dye Rhod-2 using two industrial-level CCD cameras. With the use of economical cameras and a common 532-nm diode laser for excitation, the rate dependence of voltage and calcium dynamics within the atrial and ventricular compartments can be simultaneously determined. At 140 beats/min, the atrial action potential duration was 36 ms and the transient duration was 53 ms. With the use of a programmable electrical stimulator, a shallow rate dependence of 3 and 4 ms per 100 beats/min was observed, respectively. In the ventricle the action potential duration was 109 ms and the transient duration was 124 ms, with a steeper rate dependence of 12 and 16 ms per 100 beats/min. Synchronous electrocardiograms and optical mapping recordings were recorded, in which the P-wave aligns with the atrial voltage peak and R-wave aligns with the ventricular peak. A simple optical pathway and imaging chamber are detailed along with schematics for the in-house construction of the electrocardiogram amplifier and electrical stimulator. Laboratory procedures necessary for zebrafish heart isolation, cannulation, and loading are also presented. PMID:25740339
Cruise and turning performance of an improved fish robot actuated by piezoceramic actuators
NASA Astrophysics Data System (ADS)
Nguyen, Quang Sang; Heo, Seok; Park, Hoon Cheol; Goo, Nam Seo; Byun, Doyoung
2009-03-01
The purpose of this study is improvement of a fish robot actuated by four light-weight piezocomposite actuators (LIPCAs). In the fish robot, we developed a new actuation mechanism working without any gear and thus the actuation mechanism was simple in fabrication. By using the new actuation mechanism, cross section of the fish robot became 30% smaller than that of the previous model. Performance tests of the fish robot in water were carried out to measure tail-beat angle, thrust force, swimming speed and turning radius for tail-beat frequencies from 1Hz to 5Hz. The maximum swimming speed of the fish robot was 7.7 cm/s at 3.9Hz tail-beat frequency. Turning experiment showed that swimming direction of the fish robot could be controlled with 0.41 m turning radius by controlling tail-beat angle.
The role of conductivity discontinuities in design of cardiac defibrillation
NASA Astrophysics Data System (ADS)
Lim, Hyunkyung; Cun, Wenjing; Wang, Yue; Gray, Richard A.; Glimm, James
2018-01-01
Fibrillation is an erratic electrical state of the heart, of rapid twitching rather than organized contractions. Ventricular fibrillation is fatal if not treated promptly. The standard treatment, defibrillation, is a strong electrical shock to reinitialize the electrical dynamics and allow a normal heart beat. Both the normal and the fibrillatory electrical dynamics of the heart are organized into moving wave fronts of changing electrical signals, especially in the transmembrane voltage, which is the potential difference between the cardiac cellular interior and the intracellular region of the heart. In a normal heart beat, the wave front motion is from bottom to top and is accompanied by the release of Ca ions to induce contractions and pump the blood. In a fibrillatory state, these wave fronts are organized into rotating scroll waves, with a centerline known as a filament. Treatment requires altering the electrical state of the heart through an externally applied electrical shock, in a manner that precludes the existence of the filaments and scroll waves. Detailed mechanisms for the success of this treatment are partially understood, and involve local shock-induced changes in the transmembrane potential, known as virtual electrode alterations. These transmembrane alterations are located at boundaries of the cardiac tissue, including blood vessels and the heart chamber wall, where discontinuities in electrical conductivity occur. The primary focus of this paper is the defibrillation shock and the subsequent electrical phenomena it induces. Six partially overlapping causal factors for defibrillation success are identified from the literature. We present evidence in favor of five of these and against one of them. A major conclusion is that a dynamically growing wave front starting at the heart surface appears to play a primary role during defibrillation by critically reducing the volume available to sustain the dynamic motion of scroll waves; in contrast, virtual electrodes occurring at the boundaries of small, isolated blood vessels only cause minor effects. As a consequence, we suggest that the size of the heart (specifically, the surface to volume ratio) is an important defibrillation variable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ochoukov, R.; Bobkov, V.; Faugel, H.
2015-11-15
A new B-dot probe-based diagnostic has been installed on an ASDEX Upgrade tokamak to characterize ion cyclotron range-of frequency (ICRF) wave generation and interaction with magnetized plasma. The diagnostic consists of a field-aligned array of B-dot probes, oriented to measure fast and slow ICRF wave fields and their field-aligned wavenumber (k{sub //}) spectrum on the low field side of ASDEX Upgrade. A thorough description of the diagnostic and the supporting electronics is provided. In order to compare the measured dominant wavenumber of the local ICRF fields with the expected spectrum of the launched ICRF waves, in-air near-field measurements were performedmore » on the newly installed 3-strap ICRF antenna to reconstruct the dominant launched toroidal wavenumbers (k{sub tor}). Measurements during a strap current phasing scan in tokamak discharges reveal an upshift in k{sub //} as strap phasing is moved away from the dipole configuration. This result is the opposite of the k{sub tor} trend expected from in-air near-field measurements; however, the near-field based reconstruction routine does not account for the effect of induced radiofrequency (RF) currents in the passive antenna structures. The measured exponential increase in the local ICRF wave field amplitude is in agreement with the upshifted k{sub //}, as strap phasing moves away from the dipole configuration. An examination of discharges heated with two ICRF antennas simultaneously reveals the existence of beat waves at 1 kHz, as expected from the difference of the two antennas’ operating frequencies. Beats are observed on both the fast and the slow wave probes suggesting that the two waves are coupled outside the active antennas. Although the new diagnostic shows consistent trends between the amplitude and the phase measurements in response to changes applied by the ICRF antennas, the disagreement with the in-air near-field measurements remains. An electromagnetic model is currently under development to address this issue.« less
A wavelet-based ECG delineation algorithm for 32-bit integer online processing
2011-01-01
Background Since the first well-known electrocardiogram (ECG) delineator based on Wavelet Transform (WT) presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave, QRS, and mono- or bi-phasic T wave) would make it a suitable candidate for efficient online processing of ambulatory ECG signals. Unfortunately, previous implementations of this method adopt non-linear operators such as root mean square (RMS) or floating point algebra, which are computationally demanding. Methods This paper presents a 32-bit integer, linear algebra advanced approach to online QRS detection and P-QRS-T waves delineation of a single lead ECG signal, based on WT. Results The QRS detector performance was validated on the MIT-BIH Arrhythmia Database (sensitivity Se = 99.77%, positive predictive value P+ = 99.86%, on 109010 annotated beats) and on the European ST-T Database (Se = 99.81%, P+ = 99.56%, on 788050 annotated beats). The ECG delineator was validated on the QT Database, showing a mean error between manual and automatic annotation below 1.5 samples for all fiducial points: P-onset, P-peak, P-offset, QRS-onset, QRS-offset, T-peak, T-offset, and a mean standard deviation comparable to other established methods. Conclusions The proposed algorithm exhibits reliable QRS detection as well as accurate ECG delineation, in spite of a simple structure built on integer linear algebra. PMID:21457580
A wavelet-based ECG delineation algorithm for 32-bit integer online processing.
Di Marco, Luigi Y; Chiari, Lorenzo
2011-04-03
Since the first well-known electrocardiogram (ECG) delineator based on Wavelet Transform (WT) presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave, QRS, and mono- or bi-phasic T wave) would make it a suitable candidate for efficient online processing of ambulatory ECG signals. Unfortunately, previous implementations of this method adopt non-linear operators such as root mean square (RMS) or floating point algebra, which are computationally demanding. This paper presents a 32-bit integer, linear algebra advanced approach to online QRS detection and P-QRS-T waves delineation of a single lead ECG signal, based on WT. The QRS detector performance was validated on the MIT-BIH Arrhythmia Database (sensitivity Se = 99.77%, positive predictive value P+ = 99.86%, on 109010 annotated beats) and on the European ST-T Database (Se = 99.81%, P+ = 99.56%, on 788050 annotated beats). The ECG delineator was validated on the QT Database, showing a mean error between manual and automatic annotation below 1.5 samples for all fiducial points: P-onset, P-peak, P-offset, QRS-onset, QRS-offset, T-peak, T-offset, and a mean standard deviation comparable to other established methods. The proposed algorithm exhibits reliable QRS detection as well as accurate ECG delineation, in spite of a simple structure built on integer linear algebra.
Beat-the-wave evacuation mapping for tsunami hazards in Seaside, Oregon, USA
Priest, George R.; Stimely, Laura; Wood, Nathan J.; Madin, Ian; Watzig, Rudie
2016-01-01
Previous pedestrian evacuation modeling for tsunamis has not considered variable wave arrival times or critical junctures (e.g., bridges), nor does it effectively communicate multiple evacuee travel speeds. We summarize an approach that identifies evacuation corridors, recognizes variable wave arrival times, and produces a map of minimum pedestrian travel speeds to reach safety, termed a “beat-the-wave” (BTW) evacuation analysis. We demonstrate the improved approach by evaluating difficulty of pedestrian evacuation of Seaside, Oregon, for a local tsunami generated by a Cascadia subduction zone earthquake. We establish evacuation paths by calculating the least cost distance (LCD) to safety for every grid cell in a tsunami-hazard zone using geospatial, anisotropic path distance algorithms. Minimum BTW speed to safety on LCD paths is calculated for every grid cell by dividing surface distance from that cell to safety by the tsunami arrival time at safety. We evaluated three scenarios of evacuation difficulty: (1) all bridges are intact with a 5-minute evacuation delay from the start of earthquake, (2) only retrofitted bridges are considered intact with a 5-minute delay, and (3) only retrofitted bridges are considered intact with a 10-minute delay. BTW maps also take into account critical evacuation points along complex shorelines (e.g., peninsulas, bridges over shore-parallel estuaries) where evacuees could be caught by tsunami waves. The BTW map is able to communicate multiple pedestrian travel speeds, which are typically visualized by multiple maps with current LCD-based mapping practices. Results demonstrate that evacuation of Seaside is problematic seaward of the shore-parallel waterways for those with any limitations on mobility. Tsunami vertical-evacuation refuges or additional pedestrian bridges may be effective ways of reducing loss of life seaward of these waterways.
Persistent fluctuations in stride intervals under fractal auditory stimulation.
Marmelat, Vivien; Torre, Kjerstin; Beek, Peter J; Daffertshofer, Andreas
2014-01-01
Stride sequences of healthy gait are characterized by persistent long-range correlations, which become anti-persistent in the presence of an isochronous metronome. The latter phenomenon is of particular interest because auditory cueing is generally considered to reduce stride variability and may hence be beneficial for stabilizing gait. Complex systems tend to match their correlation structure when synchronizing. In gait training, can one capitalize on this tendency by using a fractal metronome rather than an isochronous one? We examined whether auditory cues with fractal variations in inter-beat intervals yield similar fractal inter-stride interval variability as isochronous auditory cueing in two complementary experiments. In Experiment 1, participants walked on a treadmill while being paced by either an isochronous or a fractal metronome with different variation strengths between beats in order to test whether participants managed to synchronize with a fractal metronome and to determine the necessary amount of variability for participants to switch from anti-persistent to persistent inter-stride intervals. Participants did synchronize with the metronome despite its fractal randomness. The corresponding coefficient of variation of inter-beat intervals was fixed in Experiment 2, in which participants walked on a treadmill while being paced by non-isochronous metronomes with different scaling exponents. As expected, inter-stride intervals showed persistent correlations similar to self-paced walking only when cueing contained persistent correlations. Our results open up a new window to optimize rhythmic auditory cueing for gait stabilization by integrating fractal fluctuations in the inter-beat intervals.
Persistent Fluctuations in Stride Intervals under Fractal Auditory Stimulation
Marmelat, Vivien; Torre, Kjerstin; Beek, Peter J.; Daffertshofer, Andreas
2014-01-01
Stride sequences of healthy gait are characterized by persistent long-range correlations, which become anti-persistent in the presence of an isochronous metronome. The latter phenomenon is of particular interest because auditory cueing is generally considered to reduce stride variability and may hence be beneficial for stabilizing gait. Complex systems tend to match their correlation structure when synchronizing. In gait training, can one capitalize on this tendency by using a fractal metronome rather than an isochronous one? We examined whether auditory cues with fractal variations in inter-beat intervals yield similar fractal inter-stride interval variability as isochronous auditory cueing in two complementary experiments. In Experiment 1, participants walked on a treadmill while being paced by either an isochronous or a fractal metronome with different variation strengths between beats in order to test whether participants managed to synchronize with a fractal metronome and to determine the necessary amount of variability for participants to switch from anti-persistent to persistent inter-stride intervals. Participants did synchronize with the metronome despite its fractal randomness. The corresponding coefficient of variation of inter-beat intervals was fixed in Experiment 2, in which participants walked on a treadmill while being paced by non-isochronous metronomes with different scaling exponents. As expected, inter-stride intervals showed persistent correlations similar to self-paced walking only when cueing contained persistent correlations. Our results open up a new window to optimize rhythmic auditory cueing for gait stabilization by integrating fractal fluctuations in the inter-beat intervals. PMID:24651455
Effectiveness of binaural beats in reducing preoperative dental anxiety.
Isik, B K; Esen, A; Büyükerkmen, B; Kilinç, A; Menziletoglu, D
2017-07-01
Binaural beats are an auditory illusion perceived when two different pure-tone sine waves are presented one to each ear at a steady intensity and frequency. We evaluated their effectiveness in reducing preoperative anxiety in dentistry. Sixty patients (30 in each group) who were to have impacted third molars removed were studied (experimental group: 20 women and 10 men, mean (range) age 24 (18-35) years, and control group: 22 women and 8 men, mean (range) age 28 (15-47) years). All patients were fully informed about the operation preoperatively, and their anxiety recorded on a visual analogue scale (VAS). The local anaesthetic was given and the patients waited for 10minutes, during which those in the experimental group were asked to listen to binaural beats through stereo earphones (200Hz for the left ear and 209.3Hz for the right ear). No special treatment was given to the control group. In both groups anxiety was then recorded again, and the tooth removed in the usual way. The paired t test and t test were used to assess the significance of differences between groups. The degree of anxiety in the control group was unchanged after the second measurement (p=0.625), while that in the experimental group showed a significant reduction in anxiety (p=0.001). We conclude that binaural beats may be useful in reducing preoperative anxiety in dentistry. Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Nonlinear amplitude dynamics in flagellar beating
NASA Astrophysics Data System (ADS)
Oriola, David; Gadêlha, Hermes; Casademunt, Jaume
2017-03-01
The physical basis of flagellar and ciliary beating is a major problem in biology which is still far from completely understood. The fundamental cytoskeleton structure of cilia and flagella is the axoneme, a cylindrical array of microtubule doublets connected by passive cross-linkers and dynein motor proteins. The complex interplay of these elements leads to the generation of self-organized bending waves. Although many mathematical models have been proposed to understand this process, few attempts have been made to assess the role of dyneins on the nonlinear nature of the axoneme. Here, we investigate the nonlinear dynamics of flagella by considering an axonemal sliding control mechanism for dynein activity. This approach unveils the nonlinear selection of the oscillation amplitudes, which are typically either missed or prescribed in mathematical models. The explicit set of nonlinear equations are derived and solved numerically. Our analysis reveals the spatio-temporal dynamics of dynein populations and flagellum shape for different regimes of motor activity, medium viscosity and flagellum elasticity. Unstable modes saturate via the coupling of dynein kinetics and flagellum shape without the need of invoking a nonlinear axonemal response. Hence, our work reveals a novel mechanism for the saturation of unstable modes in axonemal beating.
Nonlinear amplitude dynamics in flagellar beating.
Oriola, David; Gadêlha, Hermes; Casademunt, Jaume
2017-03-01
The physical basis of flagellar and ciliary beating is a major problem in biology which is still far from completely understood. The fundamental cytoskeleton structure of cilia and flagella is the axoneme, a cylindrical array of microtubule doublets connected by passive cross-linkers and dynein motor proteins. The complex interplay of these elements leads to the generation of self-organized bending waves. Although many mathematical models have been proposed to understand this process, few attempts have been made to assess the role of dyneins on the nonlinear nature of the axoneme. Here, we investigate the nonlinear dynamics of flagella by considering an axonemal sliding control mechanism for dynein activity. This approach unveils the nonlinear selection of the oscillation amplitudes, which are typically either missed or prescribed in mathematical models. The explicit set of nonlinear equations are derived and solved numerically. Our analysis reveals the spatio-temporal dynamics of dynein populations and flagellum shape for different regimes of motor activity, medium viscosity and flagellum elasticity. Unstable modes saturate via the coupling of dynein kinetics and flagellum shape without the need of invoking a nonlinear axonemal response. Hence, our work reveals a novel mechanism for the saturation of unstable modes in axonemal beating.
Nonlinear amplitude dynamics in flagellar beating
Casademunt, Jaume
2017-01-01
The physical basis of flagellar and ciliary beating is a major problem in biology which is still far from completely understood. The fundamental cytoskeleton structure of cilia and flagella is the axoneme, a cylindrical array of microtubule doublets connected by passive cross-linkers and dynein motor proteins. The complex interplay of these elements leads to the generation of self-organized bending waves. Although many mathematical models have been proposed to understand this process, few attempts have been made to assess the role of dyneins on the nonlinear nature of the axoneme. Here, we investigate the nonlinear dynamics of flagella by considering an axonemal sliding control mechanism for dynein activity. This approach unveils the nonlinear selection of the oscillation amplitudes, which are typically either missed or prescribed in mathematical models. The explicit set of nonlinear equations are derived and solved numerically. Our analysis reveals the spatio-temporal dynamics of dynein populations and flagellum shape for different regimes of motor activity, medium viscosity and flagellum elasticity. Unstable modes saturate via the coupling of dynein kinetics and flagellum shape without the need of invoking a nonlinear axonemal response. Hence, our work reveals a novel mechanism for the saturation of unstable modes in axonemal beating. PMID:28405357
Wave propagation and noncollisional heating in neutral loop and helicon discharges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Celik, Y.; Crintea, D. L.; Luggenhoelscher, D.
2011-02-15
Heating mechanisms in two types of magnetized low pressure rf (13.56 MHz) discharges are investigated: a helicon discharge and a neutral loop discharge. Radial B-dot probe measurements demonstrate that the neutral loop discharge is sustained by helicon waves as well. Axial B-dot probe measurements reveal standing wave and beat patterns depending on the dc magnetic field strength and plasma density. In modes showing a strong wave damping, the plasma refractive index attains values around 100, leading to electron-wave interactions. In strongly damped modes, the radial plasma density profiles are mainly determined by power absorption of the propagating helicon wave, whereasmore » in weakly damped modes, inductive coupling dominates. Furthermore, an azimuthal diamagnetic drift is identified. Measurements of the helicon wave phase demonstrate that initial plane wave fronts are bent during their axial propagation due to the inhomogeneous density profile. A developed analytical standing wave model including Landau damping reproduces very well the damping of the axial helicon wave field. This comparison underlines the theory whereupon Landau damping of electrons traveling along the field lines at speeds close to the helicon phase velocity is the main damping mechanism in both discharges.« less
Dark soliton beats in the time-varying background of Bose-Einstein condensates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu Lei; Li Lu; Zhang Jiefang
2009-07-15
We investigate the dynamics of dark solitons in one-dimensional Bose-Einstein condensates. In the large particle limit, by introducing the lens-type transformation, we find that the macroscopic wave function evolves self-similarly when its initial profile strays from that of the equilibrium state, which provides a time-varying background for the propagation of dark solitons. The interaction of dark solitons with this kind of background is studied both analytically and numerically. We find that the center-of-mass motion of the dark soliton is deeply affected by the time-varying background, and the beating phenomena of dark soliton emerge when the intrinsic frequency of the darkmore » soliton approaches that of the background. Lastly, we investigate the propagation of dark solitons in the freely expanding background.« less
Coherent detection of THz laser signals in optical fiber systems.
Folland, Thomas G; Marshall, Owen P; Beere, Harvey E; Ritchie, David A; Chakraborty, Subhasish
2017-10-16
Terahertz (THz) coherent detectors are crucial for the stabilization and measurement of the properties of quantum cascade lasers (QCLs). This paper describes the exploitation of intra-cavity sum frequency generation to up-convert the emission of a THz QCL to the near infrared for detection with fiber optic coupled components alone. Specifically, a low cost infrared photodiode is used to detect a radio frequency (RF) signal with a signal-to-noise ratio of approximately 20dB, generated by beating the up-converted THz wave and a near infrared local oscillator. This RF beat note allows direct analysis of the THz QCL emission in time and frequency domains. The application of this technique for QCL characterization is demonstrated by analyzing the continuous tuning of the RF signal over 2 GHz, which arises from mode tuning across the QCL's operational current range.
Weakly Interacting Symmetric and Anti-Symmetric States in the Bilayer Systems
NASA Astrophysics Data System (ADS)
Marchewka, M.; Sheregii, E. M.; Tralle, I.; Tomaka, G.; Ploch, D.
We have studied the parallel magneto-transport in DQW-structures of two different potential shapes: quasi-rectangular and quasi-triangular. The quantum beats effect was observed in Shubnikov-de Haas (SdH) oscillations for both types of the DQW structures in perpendicular magnetic filed arrangement. We developed a special scheme for the Landau levels energies calculation by means of which we carried out the necessary simulations of beating effect. In order to obtain the agreement between our experimental data and the results of simulations, we introduced two different quasi-Fermi levels which characterize symmetric and anti-symmetric states in DQWs. The existence of two different quasi Fermi-Levels simply means, that one can treat two sub-systems (charge carriers characterized by symmetric and anti-symmetric wave functions) as weakly interacting and having their own rate of establishing the equilibrium state.
Modeling Wave Driven Non-linear Flow Oscillations: The Terrestrial QBO and a Solar Analog
NASA Technical Reports Server (NTRS)
Mayr, Hans G.; Bhartia, P. K. (Technical Monitor)
2001-01-01
The Quasi Biennial Oscillation (QBO) of the zonal circulation observed in the terrestrial atmosphere at low latitudes is driven by wave mean flow interaction as was demonstrated first by Lindzen and Holton (1968), shown in a laboratory experiment by Plumb and McEwan (1978), and modeled by others (e.g., Plumb, Dunkerton). Although influenced by the seasonal cycle of solar forcing, the QBO, in principle, represents a nonlinear flow oscillation that can be maintained by a steady source of upward propagating waves. The wave driven non-linearity is of third or odd order in the flow velocity, which regenerates the fundamental harmonic itself to keep the oscillation going - the fluid dynamical analog of the displacement mechanism in the mechanical clock. Applying Hines' Doppler Spread Parameterization (DSP) for gravity waves (GW), we discuss with a global-scale spectral model numerical experiments that elucidate some properties of the QBO and its possible effects on the climatology of the atmosphere. Depending on the period of the QBO, wave filtering can cause interaction with the seasonal variations to produce pronounced oscillations with beat periods around 10 years. Since the seasonal cycle and its variability influence the period of the QBO, it may also be a potent conduit of solar activity variations to lower altitudes. Analogous to the terrestrial QBO, we propose that a flow oscillation may account for the 22-year periodicity of the solar magnetic cycle, potentially answering Dicke (1978) who asked, "Is there a chronometer hidden deep inside the Sun?" The oscillation would occur below the convection region, where gravity waves can propagate. Employing a simplified, analytic model, Hines' DSP is applied to estimate the flow oscillation. Depending on the adopted horizontal wavelengths of GW's, wave amplitudes less than 10 m/s can be made to produce oscillating zonal flows of about 20 m/s that should be large enough to generate a significant oscillation in the magnetic field. For the large length scales of the Sun, the flow cycle period tends to be very long. The period, however, can be made to be 22 years, provided the buoyancy frequency (stability) is sufficiently small, thus placing the proposed flow near the base of the convection zone where a dynamo is now believed to operate.
Friedrich, Wernher; Du, Shengzhi; Balt, Karlien
2015-01-01
The temporal lobe in conjunction with the hippocampus is responsible for memory processing. The gamma wave is involved with this process. To develop a human brain protocol, a better understanding of the relationship between gamma and long-term memory is vital. A more comprehensive understanding of the human brain and specific analogue waves it uses will support the development of a human brain protocol. Fifty-eight participants aged between 6 and 60 years participated in long-term memory experiments. It is envisaged that the brain could be stimulated through binaural beats (sound frequency) at 40 Hz (gamma) to enhance long-term memory capacity. EEG recordings have been transformed to sound and then to an information standard, namely ASCII. Statistical analysis showed a proportional relationship between long-term memory and gamma activity. Results from EEG recordings indicate a pattern. The pattern was obtained through the de-codification of an EEG recording to sound and then to ASCII. Stimulation of gamma should enhance long term memory capacity. More research is required to unlock the human brains' protocol key. This key will enable the processing of information directly to and from human memory via gamma, the hippocampus and the temporal lobe.
From single cilia to collective waves in human airway ciliated tissues
NASA Astrophysics Data System (ADS)
Cicuta, Pietro; Chioccioli, Maurizio; Feriani, Luigi; Pellicciotta, Nicola; Kotar, Jurij
I will present experimental results on activity of motile cilia on various scales: from waveforms on individual cilia to the synchronised motion in cilia carpets of airway cells. Model synthetic experiments have given us an understanding of how cilia could couple with each other through forces transmitted by the fluid, and thus coordinate to beat into well organized waves (previous work is reviewed in Annu. Rev. Condens. Matter Phys. 7, 1-26 (2016)). Working with live imaging of airway human cells at the different scales, we can now test whether the biological system satisfies the ``simple'' behavior expected of the fluid flow coupling, or if other factors of mechanical forces transmission need to be accounted for. In general being able to link from the scale of molecular biological activity up to the phenomenology of collective dynamics requires to understand the relevant physical mechanism. This understanding then allows informed diagnostics (and perhaps therapeutic) approaches to a variety of diseases where mucociliary clearance in the airways is compromised. We have started exploring particularly cystic fibrosis, where the rheological properties of the mucus are affected and prevent efficient cilia synchronization. ERC Grant HydroSync.
Beating fantasies in a latency girl: their role in female sexual development.
Friedman, L H
1985-10-01
Detailed clinical material is presented from the analysis of a latency girl whose inner life revolved around a series of beating fantasies. The clinical data support Freud's 1925 formulation that the perception of sexual differences initiates the oedipus complex in the girl. Whether a girl experiences vaginal sensations before puberty has been a controversial issue; in this girl vaginal sensations and contractions appeared prior to puberty.
Bernstein wave aided laser third harmonic generation in a plasma
NASA Astrophysics Data System (ADS)
Tyagi, Yachna; Tripathi, Deepak; Kumar, Ashok
2016-09-01
The process of Bernstein wave aided resonant third harmonic generation of laser in a magnetized plasma is investigated. The extra-ordinary mode (X-mode) laser of frequency ω 0 and wave number k → 0 , travelling across the magnetic field in a plasma, exerts a second harmonic ponderomotive force on the electrons imparting them an oscillatory velocity v → 2 ω0 , 2 k → 0 . This velocity beats with the density perturbation due to the Bernstein wave to produce a density perturbation at cyclotron frequency shifted second harmonic. The density perturbation couples with the oscillatory velocity v → ω0 , k → 0 of X-mode of the laser to produce the cyclotron frequency shifted third harmonic current density leading to harmonic radiation. The phase matching condition for the up shifted frequency is satisfied when the Bernstein wave is nearly counter-propagating to the laser. As the transverse wave number of the Bernstein wave is large, it is effective in the phase matched third harmonic generation, when the laser frequency is not too far from the upper hybrid frequency.
NASA Astrophysics Data System (ADS)
Sauer, K.; Malaspina, D.; Pulupa, M.
2016-12-01
Instead of starting with an unstable electron beam, our focus is directed on the nonlinear response of Langmuir oscillations which are driven after beam stabilization by the still persisting current of the (stable) two-electron plasma. The velocity distribution function of the second population forms a plateau with weak damping over a more or less extended wave number range k. As shown by PIC simulations, this so-called plateau plasma drives primarily Langmuir oscillations at the plasma frequency ωe with k=0 over long times without remarkable change of the distribution function. The Langmuir oscillations, however, act as pump wave for parametric decay by which an electron-acoustic wave slightly below ωe and a counter-streaming ion-acoustic wave are generated. Both high-frequency waves have nearly the same amplitude which is simply given by the product of plateau density and velocity. Beating of these two wave types leads to pronounced Langmuir amplitude modulation, in good agreement with solar wind and foreshock WIND observations where waveforms and electron distribution functions have simultaneously been analyzed.
First Search for Gravitational Waves from the Youngest Known Neutron Star
NASA Astrophysics Data System (ADS)
Abadie, J.; Abbott, B. P.; Abbott, R.; Abernathy, M.; Adams, C.; Adhikari, R.; Ajith, P.; Allen, B.; Allen, G.; Amador Ceron, E.; Amin, R. S.; Anderson, S. B.; Anderson, W. G.; Arain, M. A.; Araya, M.; Aronsson, M.; Aso, Y.; Aston, S.; Atkinson, D. E.; Aufmuth, P.; Aulbert, C.; Babak, S.; Baker, P.; Ballmer, S.; Barker, D.; Barnum, S.; Barr, B.; Barriga, P.; Barsotti, L.; Barton, M. A.; Bartos, I.; Bassiri, R.; Bastarrika, M.; Bauchrowitz, J.; Behnke, B.; Benacquista, M.; Bertolini, A.; Betzwieser, J.; Beveridge, N.; Beyersdorf, P. T.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Biswas, R.; Black, E.; Blackburn, J. K.; Blackburn, L.; Blair, D.; Bland, B.; Bock, O.; Bodiya, T. P.; Bondarescu, R.; Bork, R.; Born, M.; Bose, S.; Boyle, M.; Brady, P. R.; Braginsky, V. B.; Brau, J. E.; Breyer, J.; Bridges, D. O.; Brinkmann, M.; Britzger, M.; Brooks, A. F.; Brown, D. A.; Buonanno, A.; Burguet-Castell, J.; Burmeister, O.; Byer, R. L.; Cadonati, L.; Camp, J. B.; Campsie, P.; Cannizzo, J.; Cannon, K. C.; Cao, J.; Capano, C.; Caride, S.; Caudill, S.; Cavaglià, M.; Cepeda, C.; Chalermsongsak, T.; Chalkley, E.; Charlton, P.; Chelkowski, S.; Chen, Y.; Christensen, N.; Chua, S. S. Y.; Chung, C. T. Y.; Clark, D.; Clark, J.; Clayton, J. H.; Conte, R.; Cook, D.; Corbitt, T. R.; Cornish, N.; Costa, C. A.; Coward, D.; Coyne, D. C.; Creighton, J. D. E.; Creighton, T. D.; Cruise, A. M.; Culter, R. M.; Cumming, A.; Cunningham, L.; Dahl, K.; Danilishin, S. L.; Dannenberg, R.; Danzmann, K.; Das, K.; Daudert, B.; Davies, G.; Davis, A.; Daw, E. J.; Dayanga, T.; DeBra, D.; Degallaix, J.; Dergachev, V.; DeRosa, R.; DeSalvo, R.; Devanka, P.; Dhurandhar, S.; Di Palma, I.; Díaz, M.; Donovan, F.; Dooley, K. L.; Doomes, E. E.; Dorsher, S.; Douglas, E. S. D.; Drever, R. W. P.; Driggers, J. C.; Dueck, J.; Dumas, J.-C.; Eberle, T.; Edgar, M.; Edwards, M.; Effler, A.; Ehrens, P.; Engel, R.; Etzel, T.; Evans, M.; Evans, T.; Fairhurst, S.; Fan, Y.; Farr, B. F.; Fazi, D.; Fehrmann, H.; Feldbaum, D.; Finn, L. S.; Flanigan, M.; Flasch, K.; Foley, S.; Forrest, C.; Forsi, E.; Fotopoulos, N.; Frede, M.; Frei, M.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Friedrich, D.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Garofoli, J. A.; Gholami, I.; Ghosh, S.; Giaime, J. A.; Giampanis, S.; Giardina, K. D.; Gill, C.; Goetz, E.; Goggin, L. M.; González, G.; Gorodetsky, M. L.; Goßler, S.; Graef, C.; Grant, A.; Gras, S.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Grosso, R.; Grote, H.; Grunewald, S.; Gustafson, E. K.; Gustafson, R.; Hage, B.; Hall, P.; Hallam, J. M.; Hammer, D.; Hammond, G.; Hanks, J.; Hanna, C.; Hanson, J.; Harms, J.; Harry, G. M.; Harry, I. W.; Harstad, E. D.; Haughian, K.; Hayama, K.; Heefner, J.; Heng, I. S.; Heptonstall, A.; Hewitson, M.; Hild, S.; Hirose, E.; Hoak, D.; Hodge, K. A.; Holt, K.; Hosken, D. J.; Hough, J.; Howell, E.; Hoyland, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Ingram, D. R.; Inta, R.; Isogai, T.; Ivanov, A.; Johnson, W. W.; Jones, D. I.; Jones, G.; Jones, R.; Ju, L.; Kalmus, P.; Kalogera, V.; Kandhasamy, S.; Kanner, J.; Katsavounidis, E.; Kawabe, K.; Kawamura, S.; Kawazoe, F.; Kells, W.; Keppel, D. G.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, H.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kondrashov, V.; Kopparapu, R.; Koranda, S.; Kozak, D.; Krause, T.; Kringel, V.; Krishnamurthy, S.; Krishnan, B.; Kuehn, G.; Kullman, J.; Kumar, R.; Kwee, P.; Landry, M.; Lang, M.; Lantz, B.; Lastzka, N.; Lazzarini, A.; Leaci, P.; Leong, J.; Leonor, I.; Li, J.; Lin, H.; Lindquist, P. E.; Lockerbie, N. A.; Lodhia, D.; Lormand, M.; Lu, P.; Luan, J.; Lubiński, M.; Lucianetti, A.; Lück, H.; Lundgren, A.; Machenschalk, B.; MacInnis, M.; Mageswaran, M.; Mailand, K.; Mak, C.; Mandel, I.; Mandic, V.; Márka, S.; Márka, Z.; Maros, E.; Martin, I. W.; Martin, R. M.; Marx, J. N.; Mason, K.; Matichard, F.; Matone, L.; Matzner, R. A.; Mavalvala, N.; McCarthy, R.; McClelland, D. E.; McGuire, S. C.; McIntyre, G.; McIvor, G.; McKechan, D. J. A.; Meadors, G.; Mehmet, M.; Meier, T.; Melatos, A.; Melissinos, A. C.; Mendell, G.; Menéndez, D. F.; Mercer, R. A.; Merill, L.; Meshkov, S.; Messenger, C.; Meyer, M. S.; Miao, H.; Miller, J.; Mino, Y.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Mohanty, S. D.; Mohapatra, S. R. P.; Moraru, D.; Moreno, G.; Morioka, T.; Mors, K.; Mossavi, K.; MowLowry, C.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Müller-Ebhardt, H.; Munch, J.; Murray, P. G.; Nash, T.; Nawrodt, R.; Nelson, J.; Newton, G.; Nishizawa, A.; Nolting, D.; Ochsner, E.; O'Dell, J.; Ogin, G. H.; Oldenburg, R. G.; O'Reilly, B.; O'Shaughnessy, R.; Osthelder, C.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Page, A.; Pan, Y.; Pankow, C.; Papa, M. A.; Pareja, M.; Patel, P.; Pedraza, M.; Pekowsky, L.; Penn, S.; Peralta, C.; Perreca, A.; Pickenpack, M.; Pinto, I. M.; Pitkin, M.; Pletsch, H. J.; Plissi, M. V.; Postiglione, F.; Predoi, V.; Price, L. R.; Prijatelj, M.; Principe, M.; Prix, R.; Prokhorov, L.; Puncken, O.; Quetschke, V.; Raab, F. J.; Radke, T.; Radkins, H.; Raffai, P.; Rakhmanov, M.; Rankins, B.; Raymond, V.; Reed, C. M.; Reed, T.; Reid, S.; Reitze, D. H.; Riesen, R.; Riles, K.; Roberts, P.; Robertson, N. A.; Robinson, C.; Robinson, E. L.; Roddy, S.; Röver, C.; Rollins, J.; Romano, J. D.; Romie, J. H.; Rowan, S.; Rüdiger, A.; Ryan, K.; Sakata, S.; Sakosky, M.; Salemi, F.; Sammut, L.; Sancho de la Jordana, L.; Sandberg, V.; Sannibale, V.; Santamaría, L.; Santostasi, G.; Saraf, S.; Sathyaprakash, B. S.; Sato, S.; Satterthwaite, M.; Saulson, P. R.; Savage, R.; Schilling, R.; Schnabel, R.; Schofield, R.; Schulz, B.; Schutz, B. F.; Schwinberg, P.; Scott, J.; Scott, S. M.; Searle, A. C.; Seifert, F.; Sellers, D.; Sengupta, A. S.; Sergeev, A.; Shaddock, D.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sibley, A.; Siemens, X.; Sigg, D.; Singer, A.; Sintes, A. M.; Skelton, G.; Slagmolen, B. J. J.; Slutsky, J.; Smith, J. R.; Smith, M. R.; Smith, N. D.; Somiya, K.; Sorazu, B.; Speirits, F. C.; Stein, A. J.; Stein, L. C.; Steinlechner, S.; Steplewski, S.; Stochino, A.; Stone, R.; Strain, K. A.; Strigin, S.; Stroeer, A.; Stuver, A. L.; Summerscales, T. Z.; Sung, M.; Susmithan, S.; Sutton, P. J.; Talukder, D.; Tanner, D. B.; Tarabrin, S. P.; Taylor, J. R.; Taylor, R.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Thüring, A.; Titsler, C.; Tokmakov, K. V.; Torres, C.; Torrie, C. I.; Traylor, G.; Trias, M.; Tseng, K.; Ugolini, D.; Urbanek, K.; Vahlbruch, H.; Vaishnav, B.; Vallisneri, M.; Van Den Broeck, C.; van der Sluys, M. V.; van Veggel, A. A.; Vass, S.; Vaulin, R.; Vecchio, A.; Veitch, J.; Veitch, P. J.; Veltkamp, C.; Villar, A.; Vorvick, C.; Vyachanin, S. P.; Waldman, S. J.; Wallace, L.; Wanner, A.; Ward, R. L.; Wei, P.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Wen, S.; Wessels, P.; West, M.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D. J.; Whiting, B. F.; Wilkinson, C.; Willems, P. A.; Williams, L.; Willke, B.; Winkelmann, L.; Winkler, W.; Wipf, C. C.; Wiseman, A. G.; Woan, G.; Wooley, R.; Worden, J.; Yakushin, I.; Yamamoto, H.; Yamamoto, K.; Yeaton-Massey, D.; Yoshida, S.; Yu, P. P.; Zanolin, M.; Zhang, L.; Zhang, Z.; Zhao, C.; Zotov, N.; Zucker, M. E.; Zweizig, J.; LIGO Scientific Collaboration
2010-10-01
We present a search for periodic gravitational waves from the neutron star in the supernova remnant Cassiopeia A. The search coherently analyzes data in a 12 day interval taken from the fifth science run of the Laser Interferometer Gravitational-Wave Observatory. It searches gravitational-wave frequencies from 100 to 300 Hz and covers a wide range of first and second frequency derivatives appropriate for the age of the remnant and for different spin-down mechanisms. No gravitational-wave signal was detected. Within the range of search frequencies, we set 95% confidence upper limits of (0.7-1.2) × 10-24 on the intrinsic gravitational-wave strain, (0.4-4) × 10-4 on the equatorial ellipticity of the neutron star, and 0.005-0.14 on the amplitude of r-mode oscillations of the neutron star. These direct upper limits beat indirect limits derived from energy conservation and enter the range of theoretical predictions involving crystalline exotic matter or runaway r-modes. This paper is also the first gravitational-wave search to present upper limits on the r-mode amplitude.
Nonlinear physics of electrical wave propagation in the heart: a review
NASA Astrophysics Data System (ADS)
Alonso, Sergio; Bär, Markus; Echebarria, Blas
2016-09-01
The beating of the heart is a synchronized contraction of muscle cells (myocytes) that is triggered by a periodic sequence of electrical waves (action potentials) originating in the sino-atrial node and propagating over the atria and the ventricles. Cardiac arrhythmias like atrial and ventricular fibrillation (AF,VF) or ventricular tachycardia (VT) are caused by disruptions and instabilities of these electrical excitations, that lead to the emergence of rotating waves (VT) and turbulent wave patterns (AF,VF). Numerous simulation and experimental studies during the last 20 years have addressed these topics. In this review we focus on the nonlinear dynamics of wave propagation in the heart with an emphasis on the theory of pulses, spirals and scroll waves and their instabilities in excitable media with applications to cardiac modeling. After an introduction into electrophysiological models for action potential propagation, the modeling and analysis of spatiotemporal alternans, spiral and scroll meandering, spiral breakup and scroll wave instabilities like negative line tension and sproing are reviewed in depth and discussed with emphasis on their impact for cardiac arrhythmias.
NASA Astrophysics Data System (ADS)
2013-11-01
WE RECOMMEND LabQuest 2 New logger now includes mobile data sharing Rubens' Tube Sturdy Rubens' tube ramps up the beat Ripple Strobe Tank Portable ripple tank makes waves in and out of the lab God and the Atom Expertly told story of the influence of atomism Maxwell's Equations Video stands the test of time Exploring Quantum Physics Through Hands-on Projects Mixture of theory and experiment hits the spot WORTH A LOOK Magnificent Principia, Exploring Isaac Newton's Masterpiece The tricky task of summarizing Newton's iconic work Talking Science: Language, Learning, and Values Interesting book tackles communication in the classroom WEB WATCH Interactive website plans a trip to Mars ... documentary peers into telescopes ... films consider the density of water
Numerical Study of Flow Augmented Thermal Management for Entry and Re-Entry Environments
NASA Technical Reports Server (NTRS)
Cheng, Gary C.; Neroorkar, Kshitij D.; Chen, Yen-Sen; Wang, Ten-See; Daso, Endwell O.
2007-01-01
The use of a flow augmented thermal management system for entry and re-entr environments is one method for reducing heat and drag loads. This concept relies on jet penetration from supersonic and hypersonic counterflowing jets that could significantly weaken and disperse the shock-wave system of the spacecraft flow field. The objective of this research effort is to conduct parametric studies of the supersonic flow over a 2.6% scale model of the Apollo capsule, with and without the counterflowing jet, using time-accurate and steady-state computational fluid dynamics simulations. The numerical studies, including different freestream Mach number angle of attack counterflowing jet mass flow rate, and nozzle configurations, were performed to examine their effect on the drag and beat loads and to explore the counternowing jet condition. The numerical results were compared with the test data obtained from transonic blow-down wind-tunnel experiments conducted independently at NASA MSFC.
[Pre- and post-orthotopic heart transplantation electrocardiogram characteristics of 998 patients].
Guan, H Q; Chen, Z J; Zhou, Y; Liu, J; Sun, W X; Yuan, J; Liao, Y H; Dong, N G; Liu, J P; Feng, K G; Zhang, Q; Zhao, X; Qian, C; Hu, F
2017-04-24
Objective: To analyze pre- and post-operation electrocardiograms (ECGs) features of patients underwent orthotopic heart transplantation (OHT), and provide evidences for identifying and analyzing post OHT ECGs. Methods: Nine hundreds and ninty-eight pre- and post- OHT standard 12-leads ECGs from 110 consecutive patients, who underwent OHT in our hospital from May 2008 to May 2014, were analyzed. Results: The mean heart rate(HR)was (86.9±16.4) beats per minute before OHT, and (100.0±0.4) beats per minute after OHT. P wave's amplitude, duration, amplitude multiplied by duration of donor heart in lead Ⅱ were (0.124±0.069)mV, (111.1±17.2)ms, (14.34±9.51)mV·ms before OHT; (0.054±0.037)mV, (86.9±27.0)ms, (5.02±4.03)mV·ms at 1 month after OHT; (0.073±0.049)mV, (93.9±17.5) ms, (7.00±4.81)mV·ms at 6 years after OHT. ECGs rotation occurred in 83.64%(92/110) patients after OHT, and prevalence of clockwise rotation was 76.36%(84/110). Sinus tachycardia was evidenced in 99.09%(109/110) patients after OHT, and incomplete right bundle branch block was present in 60.91%(67/110) patients after OHT. Pseudo complete atrioventricular block mostly occurred at 2 days after OHT. Prevalence of double sinus rhythm was 27.95%(263/941) post OHT, 40% of them occurred between the 1st and the 2nd month post OHT; the atrial rate of recipient hearts was (104.0±10.2) beats per minucte between the 3rd and the 6th month post OHT, and was (95.3±4.2) beats per minucte between the 4th year and the 5th year. P wave's amplitude, duration, amplitude multiplied by duration of recipient heart in lead Ⅱ were (0.066±0.055) mV, (52.8±34.7) ms, (4.67±4.95) mV·ms at 1 month after OHT, (0.043±0.040)mV, (44.4±40.5) ms , (3.11±3.61) mV·ms between the 1st year and 2nd year after OHT. The absolute value of P-wave(originating from the donor heart) terminal force in chest leads increased in 48.99%(461/941) patients post OHT, the P-wave terminal force of V(1) , V(2) and V(3) were -0.044(-0.066, -0.028), -0.060(-0.087, -0.038), -0.035(-0.056, 0) mm·s. Notched P wave in chest leads was presented in 10.31%(97/941) patients post OHT. PR segment depression in chest leads occurred in 60.24%(100/166) patients between the 3rd month and the 6th month, the incidence of PR segment depression in V(1) , V(2) and V(3) was 21.04%(198/941), 37.41%(352/941) and 28.69%(270/941), respectively. Conclusions: OHT is related to significantly changed ECGs. The mean HR increased significantly after OHT, then decreased gradually after half a year to one year, but it was still higher than preoperative mean HR after five or six years; the P waves of donor heart were usually inconspicuous or small in first month after OHT, and they became bigger after 2 months, and their duration and amplitude then became relatively steady afterwards. ECGs rotation, especially the clockwise rotation, was common post OHT. A variety of arrhythmias originating from the donor heart including sinus tachycardia and incomplete right bundle branch block could be found. Pseudo complete atrioventricular block could also be found in the early phase after OHT. With the extension of time, the incidence of double sinus rhythm reduced gradually. The atrial rate and P wave of recipient heart presented with a tendency to become lower. The absolute value of P-waves(originating from the donor heart) terminal force in chest leads (mainly V(1), V(2) and V(3)) increased, notched P waves in chest leads (mainly V(1), V(2)) and PR segments depression in chest leads (mainly V(2), V(3) and V(4)) also belong to typical post OHT ECGs features.
Borisyuk, Alla; Semple, Malcolm N; Rinzel, John
2002-10-01
A mathematical model was developed for exploring the sensitivity of low-frequency inferior colliculus (IC) neurons to interaural phase disparity (IPD). The formulation involves a firing-rate-type model that does not include spikes per se. The model IC neuron receives IPD-tuned excitatory and inhibitory inputs (viewed as the output of a collection of cells in the medial superior olive). The model cell possesses cellular properties of firing rate adaptation and postinhibitory rebound (PIR). The descriptions of these mechanisms are biophysically reasonable, but only semi-quantitative. We seek to explain within a minimal model the experimentally observed mismatch between responses to IPD stimuli delivered dynamically and those delivered statically (McAlpine et al. 2000; Spitzer and Semple 1993). The model reproduces many features of the responses to static IPD presentations, binaural beat, and partial range sweep stimuli. These features include differences in responses to a stimulus presented in static or dynamic context: sharper tuning and phase shifts in response to binaural beats, and hysteresis and "rise-from-nowhere" in response to partial range sweeps. Our results suggest that dynamic response features are due to the structure of inputs and the presence of firing rate adaptation and PIR mechanism in IC cells, but do not depend on a specific biophysical mechanism. We demonstrate how the model's various components contribute to shaping the observed phenomena. For example, adaptation, PIR, and transmission delay shape phase advances and delays in responses to binaural beats, adaptation and PIR shape hysteresis in different ranges of IPD, and tuned inhibition underlies asymmetry in dynamic tuning properties. We also suggest experiments to test our modeling predictions: in vitro simulation of the binaural beat (phase advance at low beat frequencies, its dependence on firing rate), in vivo partial range sweep experiments (dependence of the hysteresis curve on parameters), and inhibition blocking experiments (to study inhibitory tuning properties by observation of phase shifts).
Rhesus monkeys (Macaca mulatta) detect rhythmic groups in music, but not the beat.
Honing, Henkjan; Merchant, Hugo; Háden, Gábor P; Prado, Luis; Bartolo, Ramón
2012-01-01
It was recently shown that rhythmic entrainment, long considered a human-specific mechanism, can be demonstrated in a selected group of bird species, and, somewhat surprisingly, not in more closely related species such as nonhuman primates. This observation supports the vocal learning hypothesis that suggests rhythmic entrainment to be a by-product of the vocal learning mechanisms that are shared by several bird and mammal species, including humans, but that are only weakly developed, or missing entirely, in nonhuman primates. To test this hypothesis we measured auditory event-related potentials (ERPs) in two rhesus monkeys (Macaca mulatta), probing a well-documented component in humans, the mismatch negativity (MMN) to study rhythmic expectation. We demonstrate for the first time in rhesus monkeys that, in response to infrequent deviants in pitch that were presented in a continuous sound stream using an oddball paradigm, a comparable ERP component can be detected with negative deflections in early latencies (Experiment 1). Subsequently we tested whether rhesus monkeys can detect gaps (omissions at random positions in the sound stream; Experiment 2) and, using more complex stimuli, also the beat (omissions at the first position of a musical unit, i.e. the 'downbeat'; Experiment 3). In contrast to what has been shown in human adults and newborns (using identical stimuli and experimental paradigm), the results suggest that rhesus monkeys are not able to detect the beat in music. These findings are in support of the hypothesis that beat induction (the cognitive mechanism that supports the perception of a regular pulse from a varying rhythm) is species-specific and absent in nonhuman primates. In addition, the findings support the auditory timing dissociation hypothesis, with rhesus monkeys being sensitive to rhythmic grouping (detecting the start of a rhythmic group), but not to the induced beat (detecting a regularity from a varying rhythm).
Comb-Resolved Dual-Comb Spectroscopy Stabilized by Free-Running Continuous-Wave Lasers
NASA Astrophysics Data System (ADS)
Kuse, Naoya; Ozawa, Akira; Kobayashi, Yohei
2012-11-01
We demonstrate dual-comb spectroscopy with relatively phase-locked two frequency combs, instead of frequency combs firmly fixed to the absolute frequency references. By stabilizing two beat frequencies between two mode-locked lasers at different wavelengths observed via free-running continuous-wave (CW) lasers, two combs are tightly phase locked to each other. The frequency noise of the CW lasers barely affects the performance of dual-comb spectroscopy because of the extremely fast common-mode noise rejection. Transform-limited comb-resolved dual-comb spectroscopy with a 6 Hz radio frequency linewidth is demonstrated by the use of Yb-fiber oscillators.
Exploring the Physics of Music with Temperament Studio
NASA Astrophysics Data System (ADS)
Durfee, Dallin; Colton, John
2016-03-01
The physics of waves, resonance, harmonics, and beats has determined how musical instruments are tuned, and has even affected the kinds of music written in different time periods. The laws of physics make it impossible for any fixed scale to have perfect consonance for all chords in all keys, and as a result, various musical scales, or temperaments, have been developed and used throughout history. The study of musical temperament is a rich application of wave physics. It ties several principles together in a context which can be very motivating for students. Furthermore, the topic is accessible to students in introductory classes. We have developed an open source application called Temperament Studio which allows students to explore musical temperament and to hear and measure the effects predicted by wave physics.
Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa
2016-04-01
Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support vector machine and radial basis function method. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Theoretical studies of the solar atmosphere and interstellar pickup ions
NASA Technical Reports Server (NTRS)
1994-01-01
Solar atmosphere research activities are summarized. Specific topics addressed include: (1) coronal mass ejections and related phenomena; (2) parametric instabilities of Alfven waves; (3) pickup ions in the solar wind; and (4) cosmic rays in the outer heliosphere. Also included is a list of publications covering the following topics: catastrophic evolution of a force-free flux rope; maximum energy release in flux-rope models of eruptive flares; sheet approximations in models of eruptive flares; material ejection, motions of loops and ribbons of two-ribbon flares; dispersion relations for parametric instabilities of parallel-propagating; parametric instabilities of parallel-propagating Alfven waves; beat, modulation, and decay instabilities of a circularly-polarized Alfven wave; effects of time-dependent photoionization on interstellar pickup helium; observation of waves generated by the solar wind pickup of interstellar hydrogen ions; ion thermalization and wave excitation downstream of the quasi-perpendicular bowshock; ion cyclotron instability and the inverse correlation between proton anisotrophy and proton beta; and effects of cosmic rays and interstellar gas on the dynamics of a wind.
Ergonomic evaluation of conventional and improved methods of aonla pricking with women workers.
Rai, Arpana; Gandhi, Sudesh; Sharma, D K
2012-01-01
Conventional and improved methods of aonla pricking were evaluated ergonomically on an experiment conducted for 20 minute with women workers. The working heart rate, energy expenditure rate, total cardiac cost of work and physiological cost of work with conventional tools varied from 93-102 beats.min-1, 6-7.5 kJ.min-1, 285-470 beats, 14 -23 beats.min-1 while with machine varied from 96-105 beats.min-1, 6.5-8 kJ.min-1 , 336-540 beats, 16-27 beats.min-1 respectively. OWAS score for conventional method was 2 indicating corrective measures in near future while with machine was 1 indicating no corrective measures. Result of Nordic Musculoskeletal Questionnaire revealed that subjects complaint of pain in back, neck, right shoulder and right hand due to unnatural body posture and repetitive movement with hand tool. Moreover pricking was carried out in improper lighting conditions (200-300 lux) resulting into finger injuries from sharp edges of hand tool, whereas with machine no such problems were observed. Output with machine increased thrice than hand pricking in a given time. Machine was found useful in terms of saving time, increased productivity, enhanced safety and comfort as involved improved posture, was easy to handle and operate, thus increasing efficiency of the worker leading to better quality of life.
Effects of heart rate on experimentally produced mitral regurgitation in dogs.
Yoran, C; Yellin, E L; Hori, M; Tsujioka, K; Laniado, S; Sonnenblick, E H; Frater, R W
1983-12-01
The effects of increasing heart rate (HR) on the hemodynamics of acute mitral regurgitation (MR) were studied in 8 open-chest dogs. Filling volume, regurgitant volume and stroke volume were calculated from electromagnetic probe measurements of mitral and aortic flows. The left atrial-left ventricular systolic pressure gradient was measured with micromanometers. The calculated effective mitral regurgitant orifice area varied from 10 to 128 mm2, with a consequent regurgitant fraction (regurgitant volume/filling volume) of 24 to 62%. After crushing the sinus node, HR was increased stepwise from 90 to 180 beats/min by atrial pacing while maintaining aortic pressure constant. With increasing HR, filling volume, stroke volume, regurgitant volume and regurgitant time decreased; total cardiac output, forward cardiac output, regurgitant output, systolic pressure gradient, regurgitant fraction and the regurgitant orifice did not change; left ventricular end-diastolic pressure decreased; and left atrial v-wave amplitude increased. These results indicate that in acute experimental MR with a wide spectrum of incompetence, the relative distribution of forward and regurgitant flows did not change with large increases in HR. At rates greater than 150 beats/min the atrial contraction occurs early and increases the amplitude of the left atrial v wave. This may contribute to the severity of pulmonary congestion in patients with MR.
Active Motion Control of Tetrahymena pyriformis by Galvanotaxis and Geotaxis
NASA Astrophysics Data System (ADS)
Kim, Jihoon; Byun, Doyoung; Kim, Min Jun
2013-11-01
Recently, there has been increasing interest in the swimming behavior of microorganisms and biologically inspired micro-robots. These microorganisms naturally accompanied by complex motions. Therefore it is important to understand the flow characteristics as well as control mechanisms. One of eukaryotic cells, the protozoa are a diverse group of unicellular organisms, many of which are motile cilia. Motile cilia are cover on the surface of cell in large numbers and beat in oriented waves. Sequential beating motions of a single cilium form metachronal strokes, producing a propagation wave, and therefore the body is achieved propulsion force. So preliminary studies are achieved to understand the flow induced by swimming microorganisms. Based on hydrodynamic results, the follow study of a few micro-scale protozoa cell, such as the Tetrahymena pyriformis, has provided active or passive control into several external stimuli. In typical control methods, the galvanotaxis and geotaxis were adopted active and passive control, respectively. The validation of galvanotaxis is used DC and AC voltage. In terms of geotaxis, corrugated microstructures were used to control in the microchannel. This research was supported by the Ministry of Education, Science and Technology (MEST, 2011-0016461), National Science Foundation (NSF) CMMI Control Systems Program (#1000255) and Army Research Office (W911NF-11-1-0490).
Navigating the auditory scene: an expert role for the hippocampus.
Teki, Sundeep; Kumar, Sukhbinder; von Kriegstein, Katharina; Stewart, Lauren; Lyness, C Rebecca; Moore, Brian C J; Capleton, Brian; Griffiths, Timothy D
2012-08-29
Over a typical career piano tuners spend tens of thousands of hours exploring a specialized acoustic environment. Tuning requires accurate perception and adjustment of beats in two-note chords that serve as a navigational device to move between points in previously learned acoustic scenes. It is a two-stage process that depends on the following: first, selective listening to beats within frequency windows, and, second, the subsequent use of those beats to navigate through a complex soundscape. The neuroanatomical substrates underlying brain specialization for such fundamental organization of sound scenes are unknown. Here, we demonstrate that professional piano tuners are significantly better than controls matched for age and musical ability on a psychophysical task simulating active listening to beats within frequency windows that is based on amplitude modulation rate discrimination. Tuners show a categorical increase in gray matter volume in the right frontal operculum and right superior temporal lobe. Tuners also show a striking enhancement of gray matter volume in the anterior hippocampus, parahippocampal gyrus, and superior temporal gyrus, and an increase in white matter volume in the posterior hippocampus as a function of years of tuning experience. The relationship with gray matter volume is sensitive to years of tuning experience and starting age but not actual age or level of musicality. Our findings support a role for a core set of regions in the hippocampus and superior temporal cortex in skilled exploration of complex sound scenes in which precise sound "templates" are encoded and consolidated into memory over time in an experience-dependent manner.
Brain responses to 40-Hz binaural beat and effects on emotion and memory.
Jirakittayakorn, Nantawachara; Wongsawat, Yodchanan
2017-10-01
Gamma oscillation plays a role in binding process or sensory integration, a process by which several brain areas beside primary cortex are activated for higher perception of the received stimulus. Beta oscillation is also involved in interpreting received stimulus and occurs following gamma oscillation, and this process is known as gamma-to-beta transition, a process for neglecting unnecessary stimuli in surrounding environment. Gamma oscillation also associates with cognitive functions, memory and emotion. Therefore, modulation of the brain activity can lead to manipulation of cognitive functions. The stimulus used in this study was 40-Hz binaural beat because binaural beat induces frequency following response. This study aimed to investigate the neural oscillation responding to the 40-Hz binaural beat and to evaluate working memory function and emotional states after listening to that stimulus. Two experiments were developed based on the study aims. In the first experiment, electroencephalograms were recorded while participants listened to the stimulus for 30min. The results suggested that frontal, temporal, and central regions were activated within 15min. In the second experiment, word list recall task was conducted before and after listening to the stimulus for 20min. The results showed that, after listening, the recalled words were increase in the working memory portion of the list. Brunel Mood Scale, a questionnaire to evaluate emotional states, revealed changes in emotional states after listening to the stimulus. The emotional results suggested that these changes were consistent with the induced neural oscillations. Copyright © 2017 Elsevier B.V. All rights reserved.
[Organ procurement and transplantation from non-heart-beating donors].
Antoine, Corinne; Brun, Frédéric; Tenaillon, Alain; Loty, Bernard
2008-02-01
Despite a significant increase in procurement and transplantation activities observed in France in the last eight years, the shortage in grafts is on the rise and demand keeps being much higher than supply. Since 1968 and until now, procurement was limited to heart beating brain donors. The results of kidneys transplanted from non-heart-beating donors have significantly improved and are nowadays comparable to those of kidney transplantations from brain death donors, thanks to a more accurate selection of donors and recipients, to better respect of preventing cold and warm ischemia times and to several major therapeutic innovations. Procurement on non-heart-beating donors are therefore being reconsidered under considerations of feasibility, results and ethical and legal consequences, under a specific medical protocol issued by the agency of biomedicine with the pilot hospital center agreement to comply with the protocol. Referring to foreign experiences, this program is likely to decrease the organ shortage, which is jeopardizing the treatment of a large number of patients awaiting transplantation.
Beating dark-dark solitons and Zitterbewegung in spin-orbit-coupled Bose-Einstein condensates
NASA Astrophysics Data System (ADS)
Achilleos, V.; Frantzeskakis, D. J.; Kevrekidis, P. G.
2014-03-01
We present families of beating dark-dark solitons in spin-orbit (SO) -coupled Bose-Einstein condensates. These families consist of solitons residing simultaneously in the two bands of the energy spectrum. The soliton components are characterized by two different spatial and temporal scales, which are identified by a multiscale expansion method. The solitons are "beating" ones, as they perform density oscillations. The characteristic frequency of the latter is relevant to Zitterbewegung (ZB) oscillations, which were recently observed in experiments with SO-coupled condensates [C. Qu et al., Phys. Rev. A 88, 021604(R) (2013), 10.1103/PhysRevA.88.021604; L. J. LeBlanc et al., New J. Phys. 15, 073011 (2013), 10.1088/1367-2630/15/7/073011]. We find that spin oscillations may occur, depending on the parity of each soliton branch, which consequently lead to ZB oscillations of the beating dark solitons. Analytical results are corroborated by numerical simulations, illustrating the robustness of the solitons.
Takahashi, Goro; Sai, Sadahiro; Konishi, Akinobu
2015-09-01
Intra-atrial communication was mandatory for several congenital cardiac diseases, such as pulmonary atresia with intact ventricular septum (PA/IVS), and either sided aortoventricular valve atresia. We assessed whether the new methods of atrial septal defect(ASD)creation was effective. We experienced 4 cases of the surgical atrial septostomy performed under on-pump beating. We used a new device, a circular punch out defect creator. All cases were alive. The mean ASD diameter was enlarged from 4.37 mm to 5.55 mm and the mean ASD shunt flow was significantly decreased from 1.47 m/s to 1.11 m/s. We performed the surgical atrial septostomy using an aortic puncher under beating heart effectively and safely.
On the resonance hypothesis of storm surge and surf beat run-up
NASA Astrophysics Data System (ADS)
Postacioglu, Nazmi; Sinan Özeren, M.; Canlı, Umut
2017-06-01
Resonance has recently been proposed as the fundamental underlying mechanism that shapes the amplification in coastal run-up for storm surges and surf beats, which are long-wavelength disturbances created by fluid velocity differences between the wave groups and the regions outside the wave groups. It is without doubt that the resonance plays a role in run-up phenomena of various kinds; however, we think that the extent to which it plays its role has not been completely understood. For incident waves, which we assume to be linear, the best approach to investigate the role played by the resonance would be to calculate the normal modes by taking radiation damping into account and then testing how those modes are excited by the incident waves. Such modes diverge offshore, but they can still be used to calculate the run-up. There are a small number of previous works that attempt to calculate the resonant frequencies, but they do not relate the amplitudes of the normal modes to those of the incident wave. This is because, by not including radiation damping, they automatically induce a resonance that leads to infinite amplitudes, thus preventing them from predicting the exact contribution of the resonance to coastal run-up. In this study we consider two different coastal geometries: an infinitely wide beach with a constant slope connecting to a flat-bottomed deep ocean and a bay with sloping bottom, again, connected to a deep ocean. For the fully 1-D problem we find significant resonance if the bathymetric discontinuity is large.The linearisation of the seaward boundary condition leads to slightly smaller run-ups. For the 2-D ocean case the analysis shows that the wave confinement is very effective when the bay is narrow. The bay aspect ratio is the determining factor for the radiation damping. One reason why we include a bathymetric discontinuity is to mimic some natural settings where bays and gulfs may lead to abrupt depth gradients such as the Tokyo Bay. The other reason is, as mentioned above, to test the role played by the depth discontinuity for resonance.
Entanglement between collective fields via atomic coherence effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Xiu; Department of Physics, Xiaogan University, Xiaogan 432000; Hu Xiangming
2010-01-15
We explore the quantum entanglement between two collective fields via atomic coherence effects. For three-level atoms in V configuration driven by two applied fields on two-photon resonance, one coherent superposition of the excited states is not excited, which is the counterpart of coherent population trapping. The coherence-induced depopulation makes two cavity fields in each collection combine into a quantum-beat, i.e., equivalently, the difference mode of the two components decouples from the driven atoms. The two sum modes, when they are arranged in the four-wave mixinglike interactions, can be prepared in Einstein-Podolsky-Rosen entangled state. Correspondingly, any two individual fields from differentmore » collective modes are entangled with each other. Furthermore, the effects of thermal reservoir and laser linewidths are discussed, and a generalization is given to the case in which each quantum beat involves more than two modes.« less
Synchronization of eukaryotic flagella in vivo: from two to thousands
NASA Astrophysics Data System (ADS)
Goldstein, Raymond E.
2012-02-01
From unicellular organisms as small as a few microns to the largest vertebrates on Earth, we find groups of beating flagella or cilia that exhibit striking spatiotemporal organization. This may take the form of precise frequency and phase locking, as frequently found in the swimming of green algae, or beating with long-wavelength phase modulations known as metachronal waves, seen in ciliates such as Paramecium and in our own respiratory systems. The remarkable similarity in the underlying molecular structure of flagella across the whole eukaryotic world leads naturally to the hypothesis that a similarly universal mechanism might be responsible for synchronization. Although this mechanism is poorly understood, one appealing hypothesis is that it results from hydrodynamic interactions between flagella. This talk will summarize recent work using the unicellular alga Chlamydomonas reinhardtii and its multicellular cousin Volvox carteri to study in detail the nature of flagellar synchronization and its possible hydrodynamic origins.
Temporal interference with frequency-controllable long photons from independent cold atomic sources
NASA Astrophysics Data System (ADS)
Qian, Peng; Gu, Zhenjie; Wen, Rong; Zhang, Weiping; Chen, J. F.
2018-01-01
The interference of single photons from independent sources is an essential tool in quantum information processing. However, the interfering of photons with long temporal states in a time-resolved manner has rarely been studied. This is because without transmitting spectral filters or coupling to a cavity mode single photons generated in traditional nonlinear crystals suffer from a short temporal profile below 1 ns. With spectral correlation maintained in the biphotons generated from spontaneous four-wave mixing process in cold atom clouds, here we demonstrate the temporal interference of two frequency-tunable long photons from two independent cold atomic sources. We observe and analyze the interference of frequency-mismatched photons, where the phenomenon of the quantum beat at megahertz separation is displayed. Our paper provides more details for the quantum beat of two independent narrow-band single photons, which may find potential application in frequency-encoded photonic qubits in quantum information processing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pellat, R.; Roux, A.
1979-09-01
The propagation of electrostatic plasma waves in an inhomogeneous and magnetized plasma is studied analytically. These waves, which are driven unstable by auroral beams of electrons, are shown to suffer a further geometrical amplification while they propagate toward cut-off. Simultaneously their group velocities tend to be aligned with the geomagnetic field. Then it is shown that the electrostatic energy tends to accumulate at or near ..omega../sub L/H and ..omega../sub U/H, the local lower and upper hybrid frequencies. Due to this process, large amplitude electrostatic waves with very narrow spectra should be observed near these frequencies at any place along themore » auroral field lines where intense beam driven instability takes place. These intense quasi-monochromatic electrostatic waves are then shown to give rise by a coherent nonlinear three wave process to an intense electromagnetic radiation. Provided that the ratio ..omega../sub p/e/..omega../sub c/e tends to be smaller than unity, it is shown that the most intense radiation should be observed at 2..omega../sub U/H in the extraordinary mode.« less
Metachronal waves in epithelium cilia to transport bronchial mucus in airways
NASA Astrophysics Data System (ADS)
Favier, Julien; Sylvain, Chateau; D'Ortona, Umberto; Poncet, Sébastien
2017-11-01
Metachronal waves of beating cilia are an efficient mechanism to transport mucus in human airways. The numerical results we will present will shed new light on the understanding of chronic respiratory diseases, such as Asthma of COPD. A coupled lattice Boltzmann - Immersed Boundary is used to simulate the multiphase environment in which the cilia are immersed: a periciliary layer and the mucus layer. A purely hydrodynamical feedback of the fluids is taken into account, and a coupling parameter α is introduced, allowing the tuning of both the direction of the wave propagation, and the strength of the fluid feedback. The cilia, initially set in a random state, quickly synchronize with their immediate neighbors giving birth to metachronal waves. A comparative study of both antipleptic and sympleptic waves is performed by imposing the metachrony. Antiplectic waves are found to be the most efficient to transport and mix fluids compared to other random or synchronised cilia motions. The numerical results will be discussed and compared to experimental and clinical results obtained by collaborators, to progress on the understanding of the inner mechanisms of chronic respiratory diseases.
Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing
NASA Technical Reports Server (NTRS)
Bainum, Peter M.; Jones, Phyllis D.; Irish, Sandra M.; Xing, Guang-Qian
1998-01-01
Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.
Verrier, Richard L.; Klingenheben, Thomas; Malik, Marek; El-Sherif, Nabil; Exner, Derek V.; Hohnloser, Stefan H.; Ikeda, Takanori; Martínez, Juan Pablo; Narayan, Sanjiv M.; Nieminen, Tuomo; Rosenbaum, David S.
2014-01-01
This consensus guideline was prepared on behalf of the International Society for Holter and Noninvasive Electrocardiology and is cosponsored by the Japanese Circulation Society, the Computers in Cardiology Working Group on e-Cardiology of the European Society of Cardiology, and the European Cardiac Arrhythmia Society. It discusses the electrocardiographic phenomenon of T-wave alternans (TWA) (i.e., a beat-to-beat alternation in the morphology and amplitude of the ST- segment or T-wave). This statement focuses on its physiological basis and measurement technologies and its clinical utility in stratifying risk for life-threatening ventricular arrhythmias. Signal processing techniques including the frequency-domain Spectral Method and the time-domain Modified Moving Average method have demonstrated the utility of TWA in arrhythmia risk stratification in prospective studies in >12,000 patients. The majority of exercise-based studies using both methods have reported high relative risks for cardiovascular mortality and for sudden cardiac death in patients with preserved as well as depressed left ventricular ejection fraction. Studies with ambulatory electrocardiogram-based TWA analysis with Modified Moving Average method have yielded significant predictive capacity. However, negative studies with the Spectral Method have also appeared, including 2 interventional studies in patients with implantable defibrillators. Meta-analyses have been performed to gain insights into this issue. Frontiers of TWA research include use in arrhythmia risk stratification of individuals with preserved ejection fraction, improvements in predictivity with quantitative analysis, and utility in guiding medical as well as device-based therapy. Overall, although TWA appears to be a useful marker of risk for arrhythmic and cardiovascular death, there is as yet no definitive evidence that it can guide therapy. PMID:21920259
Frequency-modulated laser ranging sensor with closed-loop control
NASA Astrophysics Data System (ADS)
Müller, Fabian M.; Böttger, Gunnar; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Schröder, Henning; Schneider-Ramelow, Martin
2018-02-01
Advances in autonomous driving and robotics are creating high demand for inexpensive and mass-producible distance sensors. A laser ranging system (Lidar), based on the frequency-modulated continuous-wave (FMCW) method is built in this work. The benefits of an FMCW Lidar system are the low-cost components and the performance in comparison to conventional time-of-flight Lidar systems. The basic system consists of a DFB laser diode (λ= 1308 nm) and an asymmetric fiber-coupled Mach-Zehnder interferometer with a fixed delay line in one arm. Linear tuning of the laser optical frequency via injection current modulation creates a beat signal at the interferometer output. The frequency of the beat signal is proportional to the optical path difference in the interferometer. Since the laser frequency-to-current response is non-linear, a closed-loop feed-back system is designed to improve the tuning linearity, and consequently the measurement resolution. For fast active control, an embedded system with FPGA is used, resulting in a nearly linear frequency tuning, realizing a narrow peak in the Fourier spectrum of the beat signal. For free-space measurements, a setup with two distinct interferometers is built. The fully fiber-coupled Mach-Zehnder reference interferometer is part of the feed-back loop system, while the other - a Michelson interferometer - has a free-space arm with collimator lens and reflective target. A resolution of 2:0 mm for a 560 mm distance is achieved. The results for varying target distances show high consistency and a linear relation to the measured beat-frequency.
Kamoi, S; Pretty, C G; Chiew, Y S; Pironet, A; Davidson, S; Desaive, T; Shaw, G M; Chase, J G
2015-08-01
Accurate Stroke Volume (SV) monitoring is essential for patient with cardiovascular dysfunction patients. However, direct SV measurements are not clinically feasible due to the highly invasive nature of measurement devices. Current devices for indirect monitoring of SV are shown to be inaccurate during sudden hemodynamic changes. This paper presents a novel SV estimation using readily available aortic pressure measurements and aortic cross sectional area, using data from a porcine experiment where medical interventions such as fluid replacement, dobutamine infusions, and recruitment maneuvers induced SV changes in a pig with circulatory shock. Measurement of left ventricular volume, proximal aortic pressure, and descending aortic pressure waveforms were made simultaneously during the experiment. From measured data, proximal aortic pressure was separated into reservoir and excess pressures. Beat-to-beat aortic characteristic impedance values were calculated using both aortic pressure measurements and an estimate of the aortic cross sectional area. SV was estimated using the calculated aortic characteristic impedance and excess component of the proximal aorta. The median difference between directly measured SV and estimated SV was -1.4ml with 95% limit of agreement +/- 6.6ml. This method demonstrates that SV can be accurately captured beat-to-beat during sudden changes in hemodynamic state. This novel SV estimation could enable improved cardiac and circulatory treatment in the critical care environment by titrating treatment to the effect on SV.
Manipulation of the polarization of intense laser beams via optical wave mixing in plasmas
NASA Astrophysics Data System (ADS)
Michel, Pierre; Divol, Laurent; Turnbull, David; Moody, John
2014-10-01
When intense laser beams overlap in plasmas, the refractive index modulation created by the beat wave via the ponderomotive force can lead to optical wave mixing phenomena reminiscent of those used in crystals and photorefractive materials. Using a vector analysis, we present a full analytical description of the modification of the polarization state of laser beams crossing at arbitrary angles in a plasma. We show that plasmas can be used to provide full control of the polarization state of a laser beam, and give simple analytical estimates and practical considerations for the design of novel photonics devices such as plasma polarizers and plasma waveplates. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.
NASA Astrophysics Data System (ADS)
Genoud, Adrien P.; Basistyy, Roman; Williams, Gregory M.; Thomas, Benjamin P.
2018-03-01
Mosquito-borne diseases are a major challenge for Human health as they affect nearly 700 million people every year and result in over 1 million deaths. Reliable information on the evolution of population and spatial distribution of key insects species is of major importance in the development of eco-epidemiologic models. This paper reports on the remote characterization of flying mosquitoes using a continuous-wave infrared optical remote sensing system. The system is setup in a controlled environment to mimic long-range lidars, mosquitoes are free flying at a distance of 4 m from the collecting optics. The wing beat frequency is retrieved from the backscattered light from mosquitoes transiting through the laser beam. A total of 427 transit signals have been recorded from three mosquito species, males and females. Since the mosquito species and gender are known a priori, we investigate the use of wing beat frequency as the sole predictor variable for two Bayesian classifications: gender alone (two classes) and species/gender (six classes). The gender of each mosquito is retrieved with a 96.5% accuracy while the species/gender of mosquitoes is retrieved with a 62.3% accuracy. Known to be an efficient mean to identify insect family, we discuss the limitations of using wing beat frequency alone to identify insect species.
Sampling techniques for thrips (Thysanoptera: Thripidae) in preflowering tomato.
Joost, P Houston; Riley, David G
2004-08-01
Sampling techniques for thrips (Thysanoptera: Thripidae) were compared in preflowering tomato plants at the Coastal Plain Experiment Station in Tifton, GA, in 2000 and 2003, to determine the most effective method of determining abundance of thrips on tomato foliage early in the growing season. Three relative sampling techniques, including a standard insect aspirator, a 946-ml beat cup, and an insect vacuum device, were compared for accuracy to an absolute method and to themselves for precision and efficiency of sampling thrips. Thrips counts of all relative sampling methods were highly correlated (R > 0.92) to the absolute method. The aspirator method was the most accurate compared with the absolute sample according to regression analysis in 2000. In 2003, all sampling methods were considered accurate according to Dunnett's test, but thrips numbers were lower and sample variation was greater than in 2000. In 2000, the beat cup method had the lowest relative variation (RV) or best precision, at 1 and 8 d after transplant (DAT). Only the beat cup method had RV values <25 for all sampling dates. In 2003, the beat cup method had the lowest RV value at 15 and 21 DAT. The beat cup method also was the most efficient method for all sample dates in both years. Frankliniella fusca (Pergande) was the most abundant thrips species on the foliage of preflowering tomato in both years of study at this location. Overall, the best thrips sampling technique tested was the beat cup method in terms of precision and sampling efficiency.
Vandersickel, Nele; Bossu, Alexandre; De Neve, Jan; Dunnink, Albert; Meijborg, Veronique M F; van der Heyden, Marcel A G; Beekman, Jet D M; De Bakker, Jacques M T; Vos, Marc A; Panfilov, Alexander V
2017-12-26
This study investigated the arrhythmogenic mechanisms responsible for torsade de pointes (TdP) in the chronic atrioventricular block dog model, known for its high susceptibility for TdP. The mechanism of TdP arrhythmias has been under debate for many years. Focal activity as well as re-entry have both been mentioned in the initiation and the perpetuation of TdP. In 5 TdP-sensitive chronic atrioventricular block dogs, 56 needle electrodes were evenly distributed transmurally to record 240 unipolar local electrograms simultaneously. Nonterminating (NT) episodes were defibrillated after 10 s. Software was developed to automatically detect activation times and to create 3-dimensional visualizations of the arrhythmia. For each episode of ectopic activity (ranging from 2 beats to NT episodes), a novel methodology was created to construct directed graphs of the wave propagation and detect re-entry loops by using an iterative depth-first-search algorithm. Depending on the TdP definition (number of consecutive ectopic beats), we analyzed 29 to 54 TdP: 29 were longer than 5 beats. In the total group, 9 were NT and 45 were self-terminating. Initiation and termination were always based on focal activity. Re-entry becomes more important in the longer-lasting episodes (>14 beats), whereas in all NT TdP, re-entry was the last active mechanism. During re-entry, excitation fronts were constantly present in the heart, while during focal TdP, there was always a silent interval between 2 consecutive waves (142 ms) during which excitation fronts were absent. Interbeat intervals were significantly smaller for re-entry episodes-220 versus 310 ms in focal. Electrograms recorded in particular areas during NT TdP episodes had significantly smaller amplitude (0.38) than during focal episodes (0.59). TdP can be driven by focal activity as well as by re-entry depending on the duration of the episode. NT episodes are always maintained by re-entry, which can be identified in local unipolar electrograms by shorter interbeat intervals and smaller deflection amplitude. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
2012-01-01
Background It is known from recent studies that more than 90% of human multi-exon genes are subject to Alternative Splicing (AS), a key molecular mechanism in which multiple transcripts may be generated from a single gene. It is widely recognized that a breakdown in AS mechanisms plays an important role in cellular differentiation and pathologies. Polymerase Chain Reactions, microarrays and sequencing technologies have been applied to the study of transcript diversity arising from alternative expression. Last generation Affymetrix GeneChip Human Exon 1.0 ST Arrays offer a more detailed view of the gene expression profile providing information on the AS patterns. The exon array technology, with more than five million data points, can detect approximately one million exons, and it allows performing analyses at both gene and exon level. In this paper we describe BEAT, an integrated user-friendly bioinformatics framework to store, analyze and visualize exon arrays datasets. It combines a data warehouse approach with some rigorous statistical methods for assessing the AS of genes involved in diseases. Meta statistics are proposed as a novel approach to explore the analysis results. BEAT is available at http://beat.ba.itb.cnr.it. Results BEAT is a web tool which allows uploading and analyzing exon array datasets using standard statistical methods and an easy-to-use graphical web front-end. BEAT has been tested on a dataset with 173 samples and tuned using new datasets of exon array experiments from 28 colorectal cancer and 26 renal cell cancer samples produced at the Medical Genetics Unit of IRCCS Casa Sollievo della Sofferenza. To highlight all possible AS events, alternative names, accession Ids, Gene Ontology terms and biochemical pathways annotations are integrated with exon and gene level expression plots. The user can customize the results choosing custom thresholds for the statistical parameters and exploiting the available clinical data of the samples for a multivariate AS analysis. Conclusions Despite exon array chips being widely used for transcriptomics studies, there is a lack of analysis tools offering advanced statistical features and requiring no programming knowledge. BEAT provides a user-friendly platform for a comprehensive study of AS events in human diseases, displaying the analysis results with easily interpretable and interactive tables and graphics. PMID:22536968
Linewidth and tuning characteristics of terahertz quantum cascade lasers.
Barkan, A; Tittel, F K; Mittleman, D M; Dengler, R; Siegel, P H; Scalari, G; Ajili, L; Faist, J; Beere, H E; Linfield, E H; Davies, A G; Ritchie, D A
2004-03-15
We have measured the spectral linewidths of three continuous-wave quantum cascade lasers operating at terahertz frequencies by heterodyning the free-running quantum cascade laser with two far-infrared gas lasers. Beat notes are detected with a GaAs diode mixer and a microwave spectrum analyzer, permitting very precise frequency measurements and giving instantaneous linewidths of less than -30 kHz. Characteristics are also reported for frequency tuning as the injection current is varied.
Kim, Namje; Shin, Jaeheon; Sim, Eundeok; Lee, Chul Wook; Yee, Dae-Su; Jeon, Min Yong; Jang, Yudong; Park, Kyung Hyun
2009-08-03
We report on a monolithic dual-mode semiconductor laser operating in the 1550-nm range as a compact optical beat source for tunable continuous-wave (CW) terahertz (THz) generation. It consists of two distributed feedback (DFB) laser sections and one phase section between them. Each wavelength of the two modes can be independently tuned by adjusting currents in micro-heaters which are fabricated on the top of the each DFB section. The continuous tuning of the CW THz emission from Fe(+)-implanted InGaAs photomixers is successfully demonstrated using our dual-mode laser as the excitation source. The CW THz frequency is continuously tuned from 0.17 to 0.49 THz.
NASA Astrophysics Data System (ADS)
Böhnke, Frank; Scheunemann, Christian; Semmelbauer, Sebastian
2018-05-01
The propagation of traveling waves along the basilar membrane is studied in a 3D finite element model of the cochlea using single and two-tone stimulation. The advantage over former approaches is the consideration of viscous-thermal boundary layer damping which makes the usual but physically unjustified assumption of Rayleigh damping obsolete. The energy loss by viscous boundary layer damping is 70 dB lower than the actually assumed power generation by outer hair cells. The space-time course with two-tone stimulation shows the traveling waves and the periodicity of the beat frequency f2 - f1.
Ciliary metachronal wave propagation on the compliant surface of Paramecium cells.
Narematsu, Naoki; Quek, Raymond; Chiam, Keng-Hwee; Iwadate, Yoshiaki
2015-12-01
Ciliary movements in protozoa exhibit metachronal wave-like coordination, in which a constant phase difference is maintained between adjacent cilia. It is at present generally thought that metachronal waves require hydrodynamic coupling between adjacent cilia and the extracellular fluid. To test this hypothesis, we aspirated a Paramecium cell using a micropipette which completely sealed the surface of the cell such that no fluid could pass through the micropipette. Thus, the anterior and the posterior regions of the cell were hydrodynamically decoupled. Nevertheless, we still observed that metachronal waves continued to propagate from the anterior to the posterior ends of the cell, suggesting that in addition to hydrodynamic coupling, there are other mechanisms that can also transmit the metachronal waves. Such transmission was also observed in computational modeling where the fluid was fully decoupled between two partitions of a beating ciliary array. We also imposed cyclic stretching on the surface of live Paramecium cells and found that metachronal waves persisted in the presence of cyclic stretching. This demonstrated that, in addition to hydrodynamic coupling, a compliant substrate can also play a critical role in mediating the propagation of metachronal waves. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Salido-Monzú, David; Wieser, Andreas
2018-04-01
The intermode beats generated by direct detection of a mode-locked femtosecond laser represent inherent high-quality and high-frequency modulations suitable for electro-optical distance measurement (EDM). This approach has already been demonstrated as a robust alternative to standard long-distance EDM techniques. However, we extend this idea to intermode beating of a wideband source obtained by spectral broadening of a femtosecond laser. We aim at establishing a technological basis for accurate and flexible multiwavelength distance measurement. Results are presented from experiments using beat notes at 1 GHz generated by two bandpass-filtered regions from both extremes of a coherent supercontinuum ranging from 550 to 1050 nm. The displacement measurements performed simultaneously on both colors on a short-distance setup show that noise and coherence of the wideband laser are adequate for achieving accuracies of about 0.01 mm on each channel with a potential improvement by accessing higher beat notes. Pointing and power instabilities have been identified as dominant sources of systematic deviations. Nevertheless, the results demonstrate the basic feasibility of the proposed technique. We consider this a promising starting point for the further development of multiwavelength EDM enabling increased accuracy over long distances through dispersion-based integral refractivity compensation and for remote surface material probing along with distance measurement in laser scanning.
Behr, Luc; Chetboul, Valérie; Sampedrano, Carolina Carlos; Vassiliki, Gouni; Pouchelon, Jean-Louis; Laborde, François; Borenstein, Nicolas
2007-04-01
To describe an open, beating heart surgical technique and use of a bovine pericardial prosthetic valve for mitral valve replacement (MVR) in the dog. Clinical case report. Male Bull Terrier (17-month-old, 26 kg) with mitral valve dysplasia and severe regurgitation. A bovine pericardial bioprosthesis was used to replace the mitral valve using an open beating heart surgical technique and cardiopulmonary bypass. Successful MVR was achieved using a beating heart technique. Mitral regurgitation resolved and cardiac performances improved (left ventricular end-diastolic diameter decreased from 57.6 to 48.7 mm, and left atrium/aorta ratio returned to almost normal, from 1.62 to 1.19). Cardiopulmonary by-pass time and total surgical duration were decreased compared with standard cardioplegic techniques. Surgical recovery was uneventful and on echocardiography 6 months later valve function was excellent. Considering the technique advantages (no cardiac arrest, ischemic reperfusion injury, and hypothermia, or the need for aortic dissection and cannulation for administration of cardioplegic solution), short-term mortality and morbidity may be reduced compared with standard cardioplegic techniques. Based on experience in this dog, beating heart mitral valvular replacement is a seemingly safe and viable option for the dog and bovine pericardial prosthesis may provide better long-term survival than mechanical prostheses.
Vos, P G; van Dijk, A; Schomaker, L
1994-01-01
A method of time-series analysis and a time-beating experiment were used to test the structural and perceptual validity of notated metre. Autocorrelation applied to the flow of melodic intervals between notes from thirty fragments of compositions for solo instruments by J S Bach strongly supported the validity of bar length specifications. Time-beating data, obtained with four stimuli from the same set, played in an expressionless mode, and presented under categorically distinct tempos to different subgroups of musically trained subjects, were rather inconsistent with respect to tapped bar lengths. However, taps were most frequently given to the events in the stimuli that corresponded with the first beats according to the score notations. No significant effects of tempo on tapping patterns were observed. The findings are discussed in comparison with other examinations of metre inference from musical compositions.
1978-06-01
responses (AER) with a photo-optico-electronic method. Habituation was obtained by binaural stimulation with monotonously repeated clicki of a constant...Bonsper, D. E. The effect of increased information processing on sinus arrhythmia and heart beat Monti-y,7UalTfrniaITNaval Postgraduate School...September 1970. (NTIS No. ’’A’’A f śS4) This experiment investigated the eflt of increased information processing on heart beat and sinus arrhythmia. A
Application of non-linear dynamics to the characterization of cardiac electrical instability
NASA Technical Reports Server (NTRS)
Kaplan, D. T.; Cohen, R. J.
1987-01-01
Beat-to-beat alternation in the morphology of the ECG has been previously observed in hearts susceptible to fibrillation. In addition, fibrillation has been characterized by some as a chaotic state. Period doubling phenomena, such as alternation, and the onset of chaos have been connected by non-linear dynamical systems theory. In this paper, we describe the use of a technique from nonlinear dynamics theory, the construction of a first return nap, to assess the susceptibility to fibrillation threshhold in canine experiments.
Single-mode fiber, velocity interferometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krauter, K. G.; Jacobson, G. F.; Patterson, J. R.
2011-04-15
In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, wemore » demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats--this interference occurs between the ''recently'' shifted and ''formerly unshifted'' paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber.« less
Single-mode fiber, velocity interferometry.
Krauter, K G; Jacobson, G F; Patterson, J R; Nguyen, J H; Ambrose, W P
2011-04-01
In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, we demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats-this interference occurs between the "recently" shifted and "formerly unshifted" paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber. © 2011 American Institute of Physics
Transport and Mixing Induced by Beating Cilia in Human Airways
Chateau, Sylvain; D'Ortona, Umberto; Poncet, Sébastien; Favier, Julien
2018-01-01
The fluid transport and mixing induced by beating cilia, present in the bronchial airways, are studied using a coupled lattice Boltzmann—Immersed Boundary solver. This solver allows the simulation of both single and multi-component fluid flows around moving solid boundaries. The cilia are modeled by a set of Lagrangian points, and Immersed Boundary forces are computed onto these points in order to ensure the no-slip velocity conditions between the cilia and the fluids. The cilia are immersed in a two-layer environment: the periciliary layer (PCL) and the mucus above it. The motion of the cilia is prescribed, as well as the phase lag between two cilia in order to obtain a typical collective motion of cilia, known as metachronal waves. The results obtained from a parametric study show that antiplectic metachronal waves are the most efficient regarding the fluid transport. A specific value of phase lag, which generates the larger mucus transport, is identified. The mixing is studied using several populations of tracers initially seeded into the pericilary liquid, in the mucus just above the PCL-mucus interface, and in the mucus far away from the interface. We observe that each zone exhibits different chaotic mixing properties. The larger mixing is obtained in the PCL layer where only a few beating cycles of the cilia are required to obtain a full mixing, while above the interface, the mixing is weaker and takes more time. Almost no mixing is observed within the mucus, and almost all the tracers do not penetrate the PCL layer. Lyapunov exponents are also computed for specific locations to assess how the mixing is performed locally. Two time scales are introduced to allow a comparison between mixing induced by fluid advection and by molecular diffusion. These results are relevant in the context of respiratory flows to investigate the transport of drugs for patients suffering from chronic respiratory diseases. PMID:29559920
Transport and Mixing Induced by Beating Cilia in Human Airways.
Chateau, Sylvain; D'Ortona, Umberto; Poncet, Sébastien; Favier, Julien
2018-01-01
The fluid transport and mixing induced by beating cilia, present in the bronchial airways, are studied using a coupled lattice Boltzmann-Immersed Boundary solver. This solver allows the simulation of both single and multi-component fluid flows around moving solid boundaries. The cilia are modeled by a set of Lagrangian points, and Immersed Boundary forces are computed onto these points in order to ensure the no-slip velocity conditions between the cilia and the fluids. The cilia are immersed in a two-layer environment: the periciliary layer (PCL) and the mucus above it. The motion of the cilia is prescribed, as well as the phase lag between two cilia in order to obtain a typical collective motion of cilia, known as metachronal waves. The results obtained from a parametric study show that antiplectic metachronal waves are the most efficient regarding the fluid transport. A specific value of phase lag, which generates the larger mucus transport, is identified. The mixing is studied using several populations of tracers initially seeded into the pericilary liquid, in the mucus just above the PCL-mucus interface, and in the mucus far away from the interface. We observe that each zone exhibits different chaotic mixing properties. The larger mixing is obtained in the PCL layer where only a few beating cycles of the cilia are required to obtain a full mixing, while above the interface, the mixing is weaker and takes more time. Almost no mixing is observed within the mucus, and almost all the tracers do not penetrate the PCL layer. Lyapunov exponents are also computed for specific locations to assess how the mixing is performed locally. Two time scales are introduced to allow a comparison between mixing induced by fluid advection and by molecular diffusion. These results are relevant in the context of respiratory flows to investigate the transport of drugs for patients suffering from chronic respiratory diseases.
Tempo and walking speed with music in the urban context
Franěk, Marek; van Noorden, Leon; Režný, Lukáš
2014-01-01
The study explored the effect of music on the temporal aspects of walking behavior in a real outdoor urban setting. First, spontaneous synchronization between the beat of the music and step tempo was explored. The effect of motivational and non-motivational music (Karageorghis et al., 1999) on the walking speed was also studied. Finally, we investigated whether music can mask the effects of visual aspects of the walking route environment, which involve fluctuation of walking speed as a response to particular environmental settings. In two experiments, we asked participants to walk around an urban route that was 1.8 km in length through various environments in the downtown area of Hradec Králové. In Experiment 1, the participants listened to a musical track consisting of world pop music with a clear beat. In Experiment 2, participants were walking either with motivational music, which had a fast tempo and a strong rhythm, or with non-motivational music, which was slower, nice music, but with no strong implication to movement. Musical beat, as well as the sonic character of the music listened to while walking, influenced walking speed but did not lead to precise synchronization. It was found that many subjects did not spontaneously synchronize with the beat of the music at all, and some subjects synchronized only part of the time. The fast, energetic music increases the speed of the walking tempo, while slower, relaxing music makes the walking tempo slower. Further, it was found that listening to music with headphones while walking can mask the influence of the surrounding environment to some extent. Both motivational music and non-motivational music had a larger effect than the world pop music from Experiment 1. Individual differences in responses to the music listened to while walking that were linked to extraversion and neuroticism were also observed. The findings described here could be useful in rhythmic stimulation for enhancing or recovering the features of movement performance. PMID:25520682
Can Birds Perceive Rhythmic Patterns? A Review and Experiments on a Songbird and a Parrot Species
ten Cate, Carel; Spierings, Michelle; Hubert, Jeroen; Honing, Henkjan
2016-01-01
While humans can easily entrain their behavior with the beat in music, this ability is rare among animals. Yet, comparative studies in non-human species are needed if we want to understand how and why this ability evolved. Entrainment requires two abilities: (1) recognizing the regularity in the auditory stimulus and (2) the ability to adjust the own motor output to the perceived pattern. It has been suggested that beat perception and entrainment are linked to the ability for vocal learning. The presence of some bird species showing beat induction, and also the existence of vocal learning as well as vocal non-learning bird taxa, make them relevant models for comparative research on rhythm perception and its link to vocal learning. Also, some bird vocalizations show strong regularity in rhythmic structure, suggesting that birds might perceive rhythmic structures. In this paper we review the available experimental evidence for the perception of regularity and rhythms by birds, like the ability to distinguish regular from irregular stimuli over tempo transformations and report data from new experiments. While some species show a limited ability to detect regularity, most evidence suggests that birds attend primarily to absolute and not relative timing of patterns and to local features of stimuli. We conclude that, apart from some large parrot species, there is limited evidence for beat and regularity perception among birds and that the link to vocal learning is unclear. We next report the new experiments in which zebra finches and budgerigars (both vocal learners) were first trained to distinguish a regular from an irregular pattern of beats and then tested on various tempo transformations of these stimuli. The results showed that both species reduced the discrimination after tempo transformations. This suggests that, as was found in earlier studies, they attended mainly to local temporal features of the stimuli, and not to their overall regularity. However, some individuals of both species showed an additional sensitivity to the more global pattern if some local features were left unchanged. Altogether our study indicates both between and within species variation, in which birds attend to a mixture of local and to global rhythmic features. PMID:27242635
NASA Astrophysics Data System (ADS)
Zhang, Xun; Li, Xiaozhen; Hao, Hong; Wang, Dangxiong; Li, Yadong
2016-04-01
A side effect of high-speed railway and urban rail transit systems is the associated vibration and noise. Since the use of concrete viaducts is predominant in railway construction due to scarce land resources, low-frequency (20-200 Hz) structure-radiated noise from concrete bridges is a principal concern. Although it is the most commonly used bridge type, the mechanism of noise emission from box-shaped bridge girders when subjected to impact forces from moving trains, which sounds like beating a drum, has not been well studied. In this study, a field measurement was first made on a simply-supported box-shaped bridge to record the acceleration of the slabs and the associated sound pressures induced by running trains. These data indicated that a significant beat-wave noise occurred in the box-shaped cavity when the train speed was around 340 km/h, which arose from the interference between two sound waves of 75.0 Hz and 78.8 Hz. The noise leakage from the bridge expansion joint was serious and resulted in obvious noise pollution near the bridge once the beat-wave noise was generated in the cavity. The dominant frequency of the interior noise at 75.0 Hz was confirmed from the spectrum of the data and the modal analysis results, and originated from the peak vibration of the top slab due to resonance and the first-order vertical acoustic mode, which led to cavity resonance, amplifying the corresponding noise. The three-dimensional acoustic modes and local vibration modes of the slab were calculated by using the finite element method. A simplified vehicle-track-bridge coupling vibration model was then developed to calculate the wheel-rail interaction force in a frequency range of 20-200 Hz. Numerical simulations using the boundary element method confirmed the cavity resonance effect and the numerical results agreed well with the data. Based on the calibrated numerical model, three noise reduction measures, i.e., adding a horizontal baffle in the interior cavity, narrowing the width of top slab by reducing the inclination angle of the webs, and using a softer fastener on the track, were found to be effective and practical for reducing the noise generated by high-speed trains.
Binaural beats increase interhemispheric alpha-band coherence between auditory cortices.
Solcà, Marco; Mottaz, Anaïs; Guggisberg, Adrian G
2016-02-01
Binaural beats (BBs) are an auditory illusion occurring when two tones of slightly different frequency are presented separately to each ear. BBs have been suggested to alter physiological and cognitive processes through synchronization of the brain hemispheres. To test this, we recorded electroencephalograms (EEG) at rest and while participants listened to BBs or a monaural control condition during which both tones were presented to both ears. We calculated for each condition the interhemispheric coherence, which expressed the synchrony between neural oscillations of both hemispheres. Compared to monaural beats and resting state, BBs enhanced interhemispheric coherence between the auditory cortices. Beat frequencies in the alpha (10 Hz) and theta (4 Hz) frequency range both increased interhemispheric coherence selectively at alpha frequencies. In a second experiment, we evaluated whether this coherence increase has a behavioral aftereffect on binaural listening. No effects were observed in a dichotic digit task performed immediately after BBs presentation. Our results suggest that BBs enhance alpha-band oscillation synchrony between the auditory cortices during auditory stimulation. This effect seems to reflect binaural integration rather than entrainment. Copyright © 2015 Elsevier B.V. All rights reserved.
Robles-Cabrera, Adriana; Michel-Chávez, Anaclara; Callejas-Rojas, Rodolfo C; Malamud-Kessler, Caroline; Delgado, Guillermo; Estañol-Vidal, Bruno
2014-12-01
The factors that control the blood pressure are punctually regulated to keep it in reference values. These are maintained through autoregulatory mechanisms, humoral, nervous and endothelial-related. The humoral mechanisms are complex and modify the long-term blood pressure, in the other hand, the neurogenic mechanisms, are reflexive and can be observed in beat-to-beat changes of blood pressure. The nervous cardiovascular reflexes are mediated by high-pressure and low-pressure baroreceptors, as cardiovagal, cardiosympathetic and vasosympathetic. The arterial baroreceptor are stimulated when the blood volume-ejected by the ventricle distend the arterial walls. The neural discharge travels to the autonomic centers in the brain stem and the result is the modification of the heart rate and the vascular smooth muscle tone. This sudden modification is the responsible of the beat-to-beat (short-term) blood pressure variability. A review was made on the history of the physiology and experiments of the cardiovagal, cardiosympathetic and vasosympathetic baroreflexes and its influence in the short-term blood pressure variability.
The chaos and order in human ECG under the influence of the external perturbations
NASA Astrophysics Data System (ADS)
Ragulskaya, Maria; Valeriy, Pipin
The results of the many-year telecommunication heliomedical monitoring "Heliomed" show, that space weather and geophysical factor variations serve as a training factor for the adaptation-resistant member of the human population. Here we discuss the specific properties of the human ECG discovered in our experiment. The program "Heliomed" is carried out simultaneously at the different geographical areas that cover the different latitudes. The daily registered param-eters include: the psycho-emotional tests and the 1-st lead ECG, the arterial pressure, the variability cardiac contraction, the electric conduction of bioactive points on skin. The results time series compared with daily values of space weather and geomagnetic parameters. The analysis of ECG signal proceeds as follows. At first step we construct the ECG embedding into 3D phase space using the first 3 Principal Components of the ECG time series. Next, we divide ECG on the separate cycles using the maxima of the ECG's QRS complex. Then, we filter out the non-typical ECG beats by means of the Housdorff distance. Finally, we average the example of the ECG time series along the reference trajectory and study of the dynamical characteristics of the averaged ECG beat. It is found, that the ECG signal embeded in 3D phase space can be considered as a mix of a few states. At the rest, the occurrence of the primary ECG state compare to additional ones is about 8:2. The occurrence of the primary state increases after the stress. The main effect of the external perturbation is observed in structural change of the cardio-cycle and not in the variability of the R-R interval. The num-ber of none-typical cycles increase during an isolated magnetic storm. At the all monitoring centers participating experiment the same type of changes in the cardiac activity parameters is detected to go nearly simultaneously during an isolated magnetic storm. To understand the origin of the standard cardio-cycle changes we use the dynamical model reconstruction of the individual cardiac beat. It is found that the positions of the stationary points of the typical ECG attractor are in vicinities of Q and T waves. Additionally, we find that the stiffness of the beat is important for the general stability of ECG. The given results agues for the increase the relative disorder of the human cardiac system under external perturbations due to changes in the space weather and climatic factors. Also, the results of monitoring show that cardiac system can be stabilized by "internal" (physical) stress. The given difference in the cardiac sys-tem behavior under the different types of stress is obtained in the earth labaratory conditions. However, it should be considered as important factors influencing on the health of cosmonauts during the space missions, as well.
Beating the Spin-down Limit on Gravitational Wave Emission from the Vela Pulsar
NASA Astrophysics Data System (ADS)
Abadie, J.; Abbott, B. P.; Abbott, R.; Abernathy, M.; Accadia, T.; Acernese, F.; Adams, C.; Adhikari, R.; Affeldt, C.; Allen, B.; Allen, G. S.; Amador Ceron, E.; Amariutei, D.; Amin, R. S.; Anderson, S. B.; Anderson, W. G.; Antonucci, F.; Arai, K.; Arain, M. A.; Araya, M. C.; Aston, S. M.; Astone, P.; Atkinson, D.; Aufmuth, P.; Aulbert, C.; Aylott, B. E.; Babak, S.; Baker, P.; Ballardin, G.; Ballmer, S.; Barker, D.; Barnum, S.; Barone, F.; Barr, B.; Barriga, P.; Barsotti, L.; Barsuglia, M.; Barton, M. A.; Bartos, I.; Bassiri, R.; Bastarrika, M.; Basti, A.; Bauchrowitz, J.; Bauer, Th. S.; Behnke, B.; Bejger, M.; Beker, M. G.; Bell, A. S.; Belletoile, A.; Belopolski, I.; Benacquista, M.; Bertolini, A.; Betzwieser, J.; Beveridge, N.; Beyersdorf, P. T.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Birindelli, S.; Biswas, R.; Bitossi, M.; Bizouard, M. A.; Black, E.; Blackburn, J. K.; Blackburn, L.; Blair, D.; Bland, B.; Blom, M.; Bock, O.; Bodiya, T. P.; Bogan, C.; Bondarescu, R.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Boschi, V.; Bose, S.; Bosi, L.; Bouhou, B.; Boyle, M.; Braccini, S.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Brau, J. E.; Breyer, J.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Britzger, M.; Brooks, A. F.; Brown, D. A.; Brummit, A.; Budzyński, R.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Burguet-Castell, J.; Burmeister, O.; Buskulic, D.; Buy, C.; Byer, R. L.; Cadonati, L.; Cagnoli, G.; Cain, J.; Calloni, E.; Camp, J. B.; Campagna, E.; Campsie, P.; Cannizzo, J.; Cannon, K.; Canuel, B.; Cao, J.; Capano, C.; Carbognani, F.; Caride, S.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C.; Cesarini, E.; Chaibi, O.; Chalermsongsak, T.; Chalkley, E.; Charlton, P.; Chassande-Mottin, E.; Chelkowski, S.; Chen, Y.; Chincarini, A.; Christensen, N.; Chua, S. S. Y.; Chung, C. T. Y.; Chung, S.; Clara, F.; Clark, D.; Clark, J.; Clayton, J. H.; Cleva, F.; Coccia, E.; Colacino, C. N.; Colas, J.; Colla, A.; Colombini, M.; Conte, R.; Cook, D.; Corbitt, T. R.; Cornish, N.; Corsi, A.; Costa, C. A.; Coughlin, M.; Coulon, J.-P.; Coward, D. M.; Coyne, D. C.; Creighton, J. D. E.; Creighton, T. D.; Cruise, A. M.; Culter, R. M.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dahl, K.; Danilishin, S. L.; Dannenberg, R.; D'Antonio, S.; Danzmann, K.; Das, K.; Dattilo, V.; Daudert, B.; Daveloza, H.; Davier, M.; Davies, G.; Daw, E. J.; Day, R.; Dayanga, T.; De Rosa, R.; DeBra, D.; Debreczeni, G.; Degallaix, J.; del Prete, M.; Dent, T.; Dergachev, V.; DeRosa, R.; DeSalvo, R.; Dhurandhar, S.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Emilio, M. Di Paolo; Di Virgilio, A.; Díaz, M.; Dietz, A.; Donovan, F.; Dooley, K. L.; Dorsher, S.; Douglas, E. S. D.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Dumas, J.-C.; Dwyer, S.; Eberle, T.; Edgar, M.; Edwards, M.; Effler, A.; Ehrens, P.; Engel, R.; Etzel, T.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Fan, Y.; Farr, B. F.; Fazi, D.; Fehrmann, H.; Feldbaum, D.; Ferrante, I.; Fidecaro, F.; Finn, L. S.; Fiori, I.; Flaminio, R.; Flanigan, M.; Foley, S.; Forsi, E.; Forte, L. A.; Fotopoulos, N.; Fournier, J.-D.; Franc, J.; Frasca, S.; Frasconi, F.; Frede, M.; Frei, M.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Friedrich, D.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Galimberti, M.; Gammaitoni, L.; Garcia, J.; Garofoli, J. A.; Garufi, F.; Gáspár, M. E.; Gemme, G.; Genin, E.; Gennai, A.; Ghosh, S.; Giaime, J. A.; Giampanis, S.; Giardina, K. D.; Giazotto, A.; Gill, C.; Goetz, E.; Goggin, L. M.; González, G.; Gorodetsky, M. L.; Goßler, S.; Gouaty, R.; Graef, C.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Greverie, C.; Grosso, R.; Grote, H.; Grunewald, S.; Guidi, G. M.; Guido, C.; Gupta, R.; Gustafson, E. K.; Gustafson, R.; Hage, B.; Hallam, J. M.; Hammer, D.; Hammond, G.; Hanks, J.; Hanna, C.; Hanson, J.; Harms, J.; Harry, G. M.; Harry, I. W.; Harstad, E. D.; Hartman, M. T.; Haughian, K.; Hayama, K.; Hayau, J.-F.; Hayler, T.; Heefner, J.; Heitmann, H.; Hello, P.; Hendry, M. A.; Heng, I. S.; Heptonstall, A. W.; Herrera, V.; Hewitson, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Holt, K.; Hong, T.; Hooper, S.; Hosken, D. J.; Hough, J.; Howell, E. J.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Ingram, D. R.; Inta, R.; Isogai, T.; Ivanov, A.; Jaranowski, P.; Johnson, W. W.; Jones, D. I.; Jones, G.; Jones, R.; Ju, L.; Kalmus, P.; Kalogera, V.; Kandhasamy, S.; Kanner, J. B.; Katsavounidis, E.; Katzman, W.; Kawabe, K.; Kawamura, S.; Kawazoe, F.; Kells, W.; Kelner, M.; Keppel, D. G.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, H.; Kim, N.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kondrashov, V.; Kopparapu, R.; Koranda, S.; Korth, W. Z.; Kowalska, I.; Kozak, D.; Kringel, V.; Krishnamurthy, S.; Krishnan, B.; Królak, A.; Kuehn, G.; Kumar, R.; Kwee, P.; Landry, M.; Lantz, B.; Lastzka, N.; Lazzarini, A.; Leaci, P.; Leong, J.; Leonor, I.; Leroy, N.; Letendre, N.; Li, J.; Li, T. G. F.; Liguori, N.; Lindquist, P. E.; Lockerbie, N. A.; Lodhia, D.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lu, P.; Luan, J.; Lubinski, M.; Lück, H.; Lundgren, A. P.; Macdonald, E.; Machenschalk, B.; MacInnis, M.; Mageswaran, M.; Mailand, K.; Majorana, E.; Maksimovic, I.; Man, N.; Mandel, I.; Mandic, V.; Mantovani, M.; Marandi, A.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Maros, E.; Marque, J.; Martelli, F.; Martin, I. W.; Martin, R. M.; Marx, J. N.; Mason, K.; Masserot, A.; Matichard, F.; Matone, L.; Matzner, R. A.; Mavalvala, N.; McCarthy, R.; McClelland, D. E.; McGuire, S. C.; McIntyre, G.; McKechan, D. J. A.; Meadors, G.; Mehmet, M.; Meier, T.; Melatos, A.; Melissinos, A. C.; Mendell, G.; Mercer, R. A.; Merill, L.; Meshkov, S.; Messenger, C.; Meyer, M. S.; Miao, H.; Michel, C.; Milano, L.; Miller, J.; Minenkov, Y.; Mino, Y.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Miyakawa, O.; Moe, B.; Moesta, P.; Mohan, M.; Mohanty, S. D.; Mohapatra, S. R. P.; Moraru, D.; Moreno, G.; Morgado, N.; Morgia, A.; Mosca, S.; Moscatelli, V.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Müller-Ebhardt, H.; Munch, J.; Murray, P. G.; Nash, T.; Nawrodt, R.; Nelson, J.; Neri, I.; Newton, G.; Nishida, E.; Nishizawa, A.; Nocera, F.; Nolting, D.; Ochsner, E.; O'Dell, J.; Ogin, G. H.; Oldenburg, R. G.; O'Reilly, B.; O'Shaughnessy, R.; Osthelder, C.; Ott, C. D.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Page, A.; Pagliaroli, G.; Palladino, L.; Palomba, C.; Pan, Y.; Pankow, C.; Paoletti, F.; Papa, M. A.; Parameswaran, A.; Pardi, S.; Parisi, M.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patel, P.; Pathak, D.; Pedraza, M.; Pekowsky, L.; Penn, S.; Peralta, C.; Perreca, A.; Persichetti, G.; Phelps, M.; Pichot, M.; Pickenpack, M.; Piergiovanni, F.; Pietka, M.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Pletsch, H. J.; Plissi, M. V.; Podkaminer, J.; Poggiani, R.; Pöld, J.; Postiglione, F.; Prato, M.; Predoi, V.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prix, R.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Quetschke, V.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Rakhmanov, M.; Ramet, C. R.; Rankins, B.; Rapagnani, P.; Raymond, V.; Re, V.; Redwine, K.; Reed, C. M.; Reed, T.; Regimbau, T.; Reid, S.; Reitze, D. H.; Ricci, F.; Riesen, R.; Riles, K.; Roberts, P.; Robertson, N. A.; Robinet, F.; Robinson, C.; Robinson, E. L.; Rocchi, A.; Roddy, S.; Rolland, L.; Rollins, J.; Romano, J. D.; Romano, R.; Romie, J. H.; Rosińska, D.; Röver, C.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Sakata, S.; Sakosky, M.; Salemi, F.; Salit, M.; Sammut, L.; Sancho de la Jordana, L.; Sandberg, V.; Sannibale, V.; Santamaría, L.; Santiago-Prieto, I.; Santostasi, G.; Saraf, S.; Sassolas, B.; Sathyaprakash, B. S.; Sato, S.; Satterthwaite, M.; Saulson, P. R.; Savage, R.; Schilling, R.; Schlamminger, S.; Schnabel, R.; Schofield, R. M. S.; Schulz, B.; Schutz, B. F.; Schwinberg, P.; Scott, J.; Scott, S. M.; Searle, A. C.; Seifert, F.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sergeev, A.; Shaddock, D. A.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Shihan Weerathunga, T.; Shoemaker, D. H.; Sibley, A.; Siemens, X.; Sigg, D.; Singer, A.; Singer, L.; Sintes, A. M.; Skelton, G.; Slagmolen, B. J. J.; Slutsky, J.; Smith, J. R.; Smith, M. R.; Smith, N. D.; Smith, R.; Somiya, K.; Sorazu, B.; Soto, J.; Speirits, F. C.; Sperandio, L.; Stefszky, M.; Stein, A. J.; Steinlechner, J.; Steinlechner, S.; Steplewski, S.; Stochino, A.; Stone, R.; Strain, K. A.; Strigin, S.; Stroeer, A. S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sung, M.; Susmithan, S.; Sutton, P. J.; Swinkels, B.; Szokoly, G. P.; Tacca, M.; Talukder, D.; Tanner, D. B.; Tarabrin, S. P.; Taylor, J. R.; Taylor, R.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Thüring, A.; Titsler, C.; Tokmakov, K. V.; Toncelli, A.; Tonelli, M.; Torre, O.; Torres, C.; Torrie, C. I.; Tournefier, E.; Travasso, F.; Traylor, G.; Trias, M.; Tseng, K.; Turner, L.; Ugolini, D.; Urbanek, K.; Vahlbruch, H.; Vaishnav, B.; Vajente, G.; Vallisneri, M.; van den Brand, J. F. J.; Van Den Broeck, C.; van der Putten, S.; van der Sluys, M. V.; van Veggel, A. A.; Vass, S.; Vasuth, M.; Vaulin, R.; Vavoulidis, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Veltkamp, C.; Verkindt, D.; Vetrano, F.; Viceré, A.; Villar, A. E.; Vinet, J.-Y.; Vocca, H.; Vorvick, C.; Vyachanin, S. P.; Waldman, S. J.; Wallace, L.; Wanner, A.; Ward, R. L.; Was, M.; Wei, P.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Wen, S.; Wessels, P.; West, M.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D.; Whiting, B. F.; Wilkinson, C.; Willems, P. A.; Williams, H. R.; Williams, L.; Willke, B.; Winkelmann, L.; Winkler, W.; Wipf, C. C.; Wiseman, A. G.; Woan, G.; Wooley, R.; Worden, J.; Yablon, J.; Yakushin, I.; Yamamoto, H.; Yamamoto, K.; Yang, H.; Yeaton-Massey, D.; Yoshida, S.; Yu, P.; Yvert, M.; Zanolin, M.; Zhang, L.; Zhang, Z.; Zhao, C.; Zotov, N.; Zucker, M. E.; Zweizig, J.; LIGO Scientific Collaboration; Virgo Collaboration; Buchner, S.; Hotan, A.; Palfreyman, J.
2011-08-01
We present direct upper limits on continuous gravitational wave emission from the Vela pulsar using data from the Virgo detector's second science run. These upper limits have been obtained using three independent methods that assume the gravitational wave emission follows the radio timing. Two of the methods produce frequentist upper limits for an assumed known orientation of the star's spin axis and value of the wave polarization angle of, respectively, 1.9 × 10-24 and 2.2 × 10-24, with 95% confidence. The third method, under the same hypothesis, produces a Bayesian upper limit of 2.1 × 10-24, with 95% degree of belief. These limits are below the indirect spin-down limit of 3.3 × 10-24 for the Vela pulsar, defined by the energy loss rate inferred from observed decrease in Vela's spin frequency, and correspond to a limit on the star ellipticity of ~10-3. Slightly less stringent results, but still well below the spin-down limit, are obtained assuming the star's spin axis inclination and the wave polarization angles are unknown.
Control channels in the brain and their influence on brain executive functions
NASA Astrophysics Data System (ADS)
Meng, Qinglei; Choa, Fow-Sen; Hong, Elliot; Wang, Zhiguang; Islam, Mohammad
2014-05-01
In a computer network there are distinct data channels and control channels where massive amount of visual information are transported through data channels but the information streams are routed and controlled by intelligent algorithm through "control channels". Recent studies on cognition and consciousness have shown that the brain control channels are closely related to the brainwave beta (14-40 Hz) and alpha (7-13 Hz) oscillations. The high-beta wave is used by brain to synchronize local neural activities and the alpha oscillation is for desynchronization. When two sensory inputs are simultaneously presented to a person, the high-beta is used to select one of the inputs and the alpha is used to deselect the other so that only one input will get the attention. In this work we demonstrated that we can scan a person's brain using binaural beats technique and identify the individual's preferred control channels. The identified control channels can then be used to influence the subject's brain executive functions. In the experiment, an EEG measurement system was used to record and identify a subject's control channels. After these channels were identified, the subject was asked to do Stroop tests. Binaural beats was again used to produce these control-channel frequencies on the subject's brain when we recorded the completion time of each test. We found that the high-beta signal indeed speeded up the subject's executive function performance and reduced the time to complete incongruent tests, while the alpha signal didn't seem to be able to slow down the executive function performance.
On the mechanism of transverse-mode beatings in a Fabry - Perot laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, N; Ledenev, V I
2010-06-23
The mechanism of emergence of fundamental-mode and first-mode beatings in the case of a step-wise increase in the pump rate is studied under the stationary single-mode lasing conditions. Investigation is based on the numerical solution of nonstationary wave equations in a resonator in the quasi-optic approximation and on the equation for a relaxation-type medium as well as on the use of the first two Hermite - Gaussian polynomials {psi}{sub 0,1}(x) to obtain the distribution projections I{sub 0,1}(t), g{sub 0,1}(t) of the radiation intensity and gain, respectively. It is shown that the transverse-mode beatings emerge at early stages of two-mode lasing,more » the appearance of radiation intensity oscillations in the active medium preceding the development of the gain oscillations. The time of the passage of two-mode lasing to the stationary regime is determined. The phase shift {pi}/2 between the oscillations I{sub 1}(t) and g{sub 1}(t) is found for the established beating regime and the modulation depth {Delta}I averaged over the output aperture of the radiation intensity in the established two-mode regime is shown to be proportional to the pump rate excess k over the single-mode lasing threshold. A scheme for controlling the mode composition of laser radiation is proposed, which is based on the rules for determining I{sub 0,1}(t) by the sensor signals. The efficiency of the scheme is studied. The scheme employs two field intensity sensors mounted inside the resonator behind the output aperture. (resonators. modes)« less
Kinetics of atrial repolarization alternans in a free-behaving ovine model.
Jousset, Florian; Tenkorang, Joanna; Vesin, Jean-Marc; Pascale, Patrizio; Ruchat, Patrick; Rollin, Anne Garderes; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne
2012-09-01
Kinetics of Atrial Repolarization Alternans. Repolarization alternans (Re-ALT), a beat-to-beat alternation in action potential repolarization, promotes dispersion of repolarization, wavebreaks, and reentry. Recently, Re-ALT has been shown to play an important role in the transition from rapid pacing to atrial fibrillation (AF) in humans. The detailed kinetics of atrial Re-ALT, however, has not been reported so far. We developed a chronic free-behaving ovine pacing model to study the kinetics of atrial Re-ALT as a function of pacing rate. Thirteen sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms and delivery of rapid pacing protocols. Beat-to-beat differences in the atrial T-wave apex amplitude as a measure of Re-ALT and activation time were analyzed at incremental pacing rates until the effective refractory period (ERP) defined as stable 2:1 capture. Atrial Re-ALT appeared intermittently but without periodicity, and increased in amplitude as a function of pacing rate until ERP. Intermittent 2:1 atrial capture was observed at pacing cycle lengths 40 ms above ERP, and increased in duration as a function of pacing rate. Episodes of rapid pacing-induced AF were rare, and were preceded by Re-ALT or complex oscillations of atrial repolarization, but without intermittent capture. We show in vivo that atrial Re-ALT developed and increased in magnitude with rate until stable 2:1 capture. In rare instances where capture failure did not occur, Re-ALT and complex oscillations of repolarization surged and preceded AF initiation. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1003-1012, September 2012). © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Davidson, Ronald C.; McMullin, Wayne A.
1982-07-01
The relativistic motion of an electron is calculated in the combined fields of a transverse helical wiggler field (axial wavelength is λ0=2πk0) and the constant-amplitude, circularly polarized primary electromagnetic wave (δBT,ω,k) propagating in the z direction. For particle velocity near the beat-wave phase velocity ω(k+k0) of the primary wave, it is shown that the presence of a second, moderate-amplitude longitudinal wave (δÊL,ω,k) or transverse electromagnetic wave (δB2,ω2,k2) can lead to stochastic particle instability in which particles trapped near the separatrix of the primary wave undergo a systematic departure from the potential well. The condition for onset of instability is calculated, and the importance of these results for free-electron-laser (FEL) application is discussed. For development of long-pulse or steady-state free-electron lasers, the maintenance of beam integrity for an extended period of time will be of considerable practical importance. The fact that the presence of secondary, moderate-amplitude longitudinal or transverse electromagnetic waves can destroy coherent motion for certain classes of beam particles moving with velocity near ω(k+k0) may lead to a degradation of beam quality and concomitant modification of FEL emission properties.
Low-cost mm-wave Doppler/FMCW transceivers for ground surveillance applications
NASA Astrophysics Data System (ADS)
Hansen, H. J.; Lindop, R. W.; Majstorovic, D.
2005-12-01
A 35 GHz Doppler CW/FMCW transceiver (Equivalent Radiated Power ERP=30dBm) has been assembled and its operation described. Both instantaneous beat signals (relating to range in FMCW mode) and Doppler signals (relating to targets moving at ~1.5 ms -1) exhibit audio frequencies. Consequently, the radar processing is provided by laptop PC using its inbuilt video-audio media system with appropriate MathWorks software. The implications of radar-on-chip developments are addressed.
Insect remote sensing using a polarization sensitive cw lidar system in chinese rice fields
NASA Astrophysics Data System (ADS)
Zhu, Shiming; Malmqvist, Elin; Li, Yiyun; Jansson, Samuel; Li, Wansha; Duan, Zheng; Fu, Wei; Svanberg, Katarina; Bood, Joakim; Feng, Hongqiang; Åkesson, Susanne; Song, Ziwei; Zhang, Baoxin; Zhao, Guangyu; Li, Dunsong; Brydegaard, Mikkel; Svanberg, Sune
2018-04-01
A joint Chinese-Swedish field campaign of Scheimpflug continuous-wave lidar monitoring of rice-field flying pest insects was pursued in very hot July weather conditions close to Guangzhou, China. The occurrence of insects, birds and bats with almost 200 hours of round-the-clock polarization-sensitive recordings was studied. Wing-beat frequency recordings and depolarization properties were used for target classification. Influence of weather conditions on the flying fauna was also investigated.
NASA Technical Reports Server (NTRS)
Estes, N. A. 3rd; Michaud, G.; Zipes, D. P.; El-Sherif, N.; Venditti, F. J.; Rosenbaum, D. S.; Albrecht, P.; Wang, P. J.; Cohen, R. J.
1997-01-01
This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.
T wave alternans during exercise and atrial pacing in humans
NASA Technical Reports Server (NTRS)
Hohnloser, S. H.; Klingenheben, T.; Zabel, M.; Li, Y. G.; Albrecht, P.; Cohen, R. J.
1997-01-01
INTRODUCTION: Evidence is accumulating that microvolt T wave alternans (TWA) is a marker of increased risk for ventricular tachyarrhythmias. Initially, atrial pacing was used to elevate heart rate and elicit TWA. More recently, a noninvasive approach has been developed that elevates heart rate using exercise. METHODS AND RESULTS: In 30 consecutive patients with a history of ventricular tachyarrhythmias, the spectral method was used to detect TWA during both atrial pacing and submaximal exercise testing. The concordance rate for the presence or absence of TWA using the two measurement methods was 84%. There was a patient-specific heart rate threshold for the detection of TWA that averaged 100 +/- 14 beats/min during exercise compared with 97 +/- 9 beats/min during right atrial pacing (P = NS). Beyond this threshold, there was a significant and comparable increase in level of TWA with decreasing pacing cycle length and increasing exercise heart rates. CONCLUSIONS: The present study is the first to demonstrate that microvolt TWA can be assessed reliably and noninvasively during exercise stress. There is a patient-specific heart rate threshold beyond which TWA continues to increase with increasing heart rates. Heart rate thresholds for the onset of TWA measured during atrial pacing and exercise stress were comparable, indicating that heart rate alone appears to be the main factor of determining the onset of TWA during submaximal exercise stress.
NASA Technical Reports Server (NTRS)
Karpoukhin, Mikhii G.; Kogan, Boris Y.; Karplus, Walter J.
1995-01-01
The simulation of heart arrhythmia and fibrillation are very important and challenging tasks. The solution of these problems using sophisticated mathematical models is beyond the capabilities of modern super computers. To overcome these difficulties it is proposed to break the whole simulation problem into two tightly coupled stages: generation of the action potential using sophisticated models. and propagation of the action potential using simplified models. The well known simplified models are compared and modified to bring the rate of depolarization and action potential duration restitution closer to reality. The modified method of lines is used to parallelize the computational process. The conditions for the appearance of 2D spiral waves after the application of a premature beat and the subsequent traveling of the spiral wave inside the simulated tissue are studied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khalili, Farid; Danilishin, Stefan; Mueller-Ebhardt, Helge
We consider enhancing the sensitivity of future gravitational-wave detectors by using double optical spring. When the power, detuning and bandwidth of the two carriers are chosen appropriately, the effect of the double optical spring can be described as a 'negative inertia', which cancels the positive inertia of the test masses and thus increases their response to gravitational waves. This allows us to surpass the free-mass standard quantum limit (SQL) over a broad frequency band, through signal amplification, rather than noise cancellation, which has been the case for all broadband SQL-beating schemes so far considered for gravitational-wave detectors. The merit ofmore » such signal amplification schemes lies in the fact that they are less susceptible to optical losses than noise-cancellation schemes. We show that it is feasible to demonstrate such an effect with the Gingin High Optical Power Test Facility, and it can eventually be implemented in future advanced GW detectors.« less
Evaluation of Flow Biosensor Technology in a Chronically-Instrumented Non-Human Primate Model
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Reister, C.; Schaub, J.; Muniz, G.; Ferguson, T.; Fanton, J. W.
1995-01-01
The Physiology Research Branch of Brooks AFB conducts both human and non-human primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to indentify the particular mechanisms that invoke these responses. Primary investigative research efforts in a non-human primate model require the calculation of total peripheral resistance (TPR), systemic arterial compliance (SAC), and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. We have evaluated commercially available electromagnetic (EMF) and transit-time flow measurement techniques. In vivo and in vitro experiments demonstrated that the average error of these techniques is less than 25 percent for EMF and less than 10 percent for transit-time.
Effect of cardiac resynchronization therapy on beat-to-beat T-wave amplitude variability.
Žižek, David; Cvijić, Marta; Tasič, Jerneja; Jan, Matevž; Frljak, Sabina; Zupan, Igor
2012-11-01
T-wave amplitude variability (TAV) is a promising non-invasive predictor of arrhythmic events in patients with dilated cardiomyopathy. We aimed to evaluate the effect of cardiac resynchronization therapy (CRT) on native TAV, its relation with left ventricular (LV) reverse remodelling and the occurrence of ventricular tachyarrhythmias (VTs). In this prospective study, we included 40 heart failure patients with left bundle branch block in sinus rhythm (25 male; 16 with ischaemic aetiology; aged 62.7 ± 9.5 years; New York Heart Association class II-IV). Echocardiographic parameters and TAV were evaluated at baseline and 6 months after implantation of CRT device combined with an implantable cardioverter-defibrillator. T-wave amplitude variability was determined by a 20-min high-resolution electrocardiogram Holter recording during native conduction. After TAV assessment, patients were monitored for 15.7 ± 5.2 months for the occurrence of VTs. Decrease in median TAV [from 40.45 μV (24.75-56.00) to 28.15 μV (20.93-37.95), P = 0.004] was observed after 6 months of CRT. However, decrease of median TAV was only noticed in patients with LV reverse remodelling [46.9 μV (27.5-70.0) to 25.8 μV (20.2-32.4), P < 0.001] and in patients without VTs [40.5 μV (27.5-55.9) to 24.4 μV (17.1-31.5), P < 0.001]. Native median TAV > 35.4 µV after 6 months of CRT had an 83% sensitivity and 93% specificity for predicting the occurrence of VTs. Decrease of TAV after CRT is associated with LV reverse remodelling and indicates a reduction of the intrinsic arrhythmogenic substrate. Median TAV after CRT had a good predicting value for VT occurrence in long-term follow-up.
NASA Technical Reports Server (NTRS)
Roux, A.; Pellat, R.
1978-01-01
The propagation of electrostatic plasma waves in an inhomogeneous and magnetized plasma was studied. These waves, which are driven unstable by auroral beams of electrons, are shown to suffer a further geometrical amplification while they propagate towards resonances. Simultaneously, their group velocities tend to be aligned with the geomagnetic field. It is shown that the electrostatic energy tends to accumulate at, or near omega sub LH and omega sub UH, the local lower and upper hybrid frequencies. Due to this process, large amplitude electrostatic waves with very narrow spectra are observed near these frequencies at any place along the auroral field lines where intense beam driven instability takes place. These intense quasi-monochromatic electrostatic waves are shown to give rise to an intense electromagnetic radiation. Depending upon the ratio omega sub pe/omega sub ce between the electron plasma frequency and the electron gyro-frequency the electromagnetic wave can be radiated in the ordinary mode (at omega sub UH), or in the extraordinary (at 2 omega sub UH). As the ratio omega sub pe/omega sub ce tends to be rather small, it is shown that the most intense radiation should be boserved at 2 omega sub UH in the extraordinary mode.
Flagellar coordination in Chlamydomonas cells held on micropipettes.
Rüffer, U; Nultsch, W
1998-01-01
The two flagella of Chlamydomonas are known to beat synchronously: During breaststroke beating they are generally coordinated in a bilateral way while in shock responses during undulatory beating coordination is mostly parallel [Rüffer and Nultsch, 1995: Botanica Acta 108:169-276]. Analysis of a great number of shock responses revealed that in undulatory beats also periods of bilateral coordination are found and that the coordination type may change several times during a shock response, without concomitant changes of the beat envelope and the beat period. In normal wt cells no coordination changes are found during breaststroke beating, but only short temporary asynchronies: During 2 or 3 normal beats of the cis flagellum, the trans flagellum performs 3 or 4 flat beats with a reduced beat envelope and a smaller beat period, resulting in one additional trans beat. Long periods with flat beats of the same shape and beat period are found in both flagella of the non-phototactic mutant ptx1 and in defective wt 622E cells. During these periods, the coordination is parallel, the two flagella beat alternately. A correlation between normal asynchronous trans beats and the parallel-coordinated beats in the presumably cis defective cells and also the undulatory beats is discussed. In the cis defective cells, a perpetual spontaneous change between parallel beats with small beat periods (higher beat frequency) and bilateral beats with greater beat periods (lower beat frequency) are observed and render questionable the existence of two different intrinsic beat frequencies of the two flagella cis and trans. Asynchronies occur spontaneously but may also be induced by light changes, either step-up or step-down, but not by both stimuli in turn as breaststroke flagellar photoresponses (BFPRs). Asynchronies are not involved in phototaxis. They are independent of the BFPRs, which are supposed to be the basis of phototaxis. Both types of coordination must be assumed to be regulated internally, involving calcium-sensitive basal-body associated fibrous structures.
Kim, Namje; Han, Sang-Pil; Ryu, Han-Cheol; Ko, Hyunsung; Park, Jeong-Woo; Lee, Donghun; Jeon, Min Yong; Park, Kyung Hyun
2012-07-30
A widely tunable dual mode laser diode with a single cavity structure is demonstrated. This novel device consists of a distributed feedback (DFB) laser diode and distributed Bragg reflector (DBR). Micro-heaters are integrated on the top of each section for continuous and independent wavelength tuning of each mode. By using a single gain medium in the DFB section, an effective common optical cavity and common modes are realized. The laser diode shows a wide tunability of the optical beat frequency, from 0.48 THz to over 2.36 THz. Continuous wave THz radiation is also successfully generated with low-temperature grown InGaAs photomixers from 0.48 GHz to 1.5 THz.
NASA Technical Reports Server (NTRS)
Johnson, Adriel D.
1992-01-01
Conditions simulating low- and high-gravity, reveal changes in macroscopic pattern formation in selected microorganisms, but whether these structures are gravity dependent is not clear. Two theories have been identified in the fluid dynamics community which support macroscopic pattern formation. The first one is gravity dependent (fluid density models) where small concentrated regions of organisms sink unstably, and the second is gravity independent (wave reinforcement theory) where organisms align their movements in concert, such that either their swimming strokes beat in phase or their vortices entrain neighbors to follow parallel paths. Studies have shown that macroscopic pattern formation is consistent with the fluid density models for protozoa and algae and wave reinforcement hypothesis for caprine spermatozoa.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uchida, K.; Hirori, H., E-mail: hirori@icems.kyoto-u.ac.jp; CREST, Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012
2015-11-30
By combining a tilted-pulse-intensity-front scheme using a LiNbO{sub 3} crystal and a chirped-pulse-beating method, we generated a narrowband intense terahertz (THz) pulse, which had a maximum electric field of more than 10 kV/cm at around 2 THz, a bandwidth of ∼50 GHz, and frequency tunability from 0.5 to 2 THz. By performing THz-pump and near-infrared-probe experiments on GaAs quantum wells, we observed that the resonant excitation of the intraexcitonic 1s-2p transition induces a clear and large Autler-Townes splitting. Our time-resolved measurements show that the splitting energy observed in the rising edge region of electric field is larger than in the constant region.more » This result implies that the splitting energy depends on the time-averaged THz field over the excitonic dephasing time rather than that at the instant of the exciton creation by a probe pulse.« less
A New Principle of Sound Frequency Analysis
NASA Technical Reports Server (NTRS)
Theodorsen, Theodore
1932-01-01
In connection with the study of aircraft and propeller noises, the National Advisory Committee for Aeronautics has developed an instrument for sound-frequency analysis which differs fundamentally from previous types, and which, owing to its simplicity of principle, construction, and operation, has proved to be of value in this investigation. The method is based on the well-known fact that the Ohmic loss in an electrical resistance is equal to the sum of the losses of the harmonic components of a complex wave, except for the case in which any two components approach or attain vectorial identity, in which case the Ohmic loss is increased by a definite amount. The principle of frequency analysis has been presented mathematically and a number of distinct advantages relative to previous methods have been pointed out. An automatic recording instrument embodying this principle is described in detail. It employs a beat-frequency oscillator as a source of variable frequency. A large number of experiments have verified the predicted superiority of the method. A number of representative records are presented.
Influence of a falling edge on high power microwave pulse combination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jiawei; Huang, Wenhua; Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi'an 710024
This paper presents an explanation of the influence of a microwave falling edge on high-power microwave pulse combination. Through particle-in-cell simulations, we discover that the falling edge is the driving factor that limits the output power of the combined pulses. We demonstrate that the space charge field, which accumulates to become comparable to the E-field at the falling edge of the former pulse, will trap the electrons in the gas layer and decrease its energy to attain a high ionization rate. Hence, avalanche discharge, caused by trapped electrons, makes the plasma density to approach the critical density and cuts offmore » the latter microwave pulse. An X-band combination experiment is conducted with different pulse intervals. This experiment confirms that the high density plasma induced by the falling edge can cut off the latter pulse, and that the time required for plasma recombination in the transmission channel is several microseconds. To ensure a high output power for combined pulses, the latter pulse should be moved ahead of the falling edge of the former one, and consequently, a beat wave with high peak power becomes the output by adding two pulses with normal amplitudes.« less
Influence of a falling edge on high power microwave pulse combination
NASA Astrophysics Data System (ADS)
Li, Jiawei; Huang, Wenhua; Zhu, Qi; Xiao, Renzhen; Shao, Hao
2016-07-01
This paper presents an explanation of the influence of a microwave falling edge on high-power microwave pulse combination. Through particle-in-cell simulations, we discover that the falling edge is the driving factor that limits the output power of the combined pulses. We demonstrate that the space charge field, which accumulates to become comparable to the E-field at the falling edge of the former pulse, will trap the electrons in the gas layer and decrease its energy to attain a high ionization rate. Hence, avalanche discharge, caused by trapped electrons, makes the plasma density to approach the critical density and cuts off the latter microwave pulse. An X-band combination experiment is conducted with different pulse intervals. This experiment confirms that the high density plasma induced by the falling edge can cut off the latter pulse, and that the time required for plasma recombination in the transmission channel is several microseconds. To ensure a high output power for combined pulses, the latter pulse should be moved ahead of the falling edge of the former one, and consequently, a beat wave with high peak power becomes the output by adding two pulses with normal amplitudes.
A sliding-control switch stabilizes synchronized states in a model of actuated cilia
NASA Astrophysics Data System (ADS)
Buchmann, Amy; Cortez, Ricardo; Fauci, Lisa
2017-11-01
A key function of cilia, flexible hairlike appendages located on the surface of a cell, is the transport of mucus in the lungs, where the cilia self-organize forming a metachronal wave that propels the surrounding fluid. Cilia also play an important role in the locomotion of ciliated microswimmers and other biological processes. To analyze the coordinated movement of cilia interacting through a fluid, we model each cilium as an elastic, actuated body whose beat pattern is driven by a geometric switch that drives the motion of the power and recovery strokes. The cilia are coupled to the viscous fluid using a numerical method based upon a centerline distribution of regularized Stokeslets. We first characterize the beat cycle and flow produced by a single cilium and then present results on the synchronization states between two cilia that show that the in-phase equilibrium is unstable while the anti-phase equilibrium is stable under the geometric switch model. Adding a sliding-control switching mechanism stabilizes the in-phase motion.
Research of the Heart Information Monitoring Robert Based on the 3G Wireless Communication Platform
NASA Astrophysics Data System (ADS)
Zhang, Fuli; Yang, Huazhe; Li, Gensong; Hong, Yang; Hu, Qingzhe
Electrocardiogram (ECG) of a person can be recorded and the diagnostic results can be displayed through touching the heart information monitoring Robert. In addition, the heart rate, phonocardiogram (PCG) and the dynamic three-dimensional echocardiography can also be displayed synchronously. Then the difficult ECG can be transmitted to the service center through 3G wireless communication center, followed by diagnosing the ECG by doctors and transmitting the feedback diagnostic results. I-lead ECG of the person can be recorded by the amplification circuit with high gain and low noise. Then, the heart rate and output phonocardiogram are displayed and the model of heart beat are started to trace through the recognition of R wave. Finally, the difficult ECG is transmitted to the service center via 3G communication chips. The displayed ECG is clear, and the stimulated heart beat is synchronous with that of the person. Furthermore, ECG received by the service center is in accordance with the one recorded by the Robert.
Jacquin, Olivier; Lacot, Eric; Glastre, Wilfried; Hugon, Olivier; Guillet de Chatellus, Hugues
2011-08-01
Using an Nd:YVO₄ microchip laser with a relaxation frequency in the megahertz range, we have experimentally compared a heterodyne interferometer based on a Michelson configuration with an autodyne interferometer based on the laser optical feedback imaging (LOFI) method regarding their signal-to-noise ratios. In the heterodyne configuration, the beating between the reference beam and the signal beam is realized outside the laser cavity, while in the autodyne configuration, the wave beating takes place inside the laser cavity, and the relaxation oscillations of the laser intensity then play an important part. For a given laser output power, object under investigation, and detection noise level, we have determined the amplification gain of the LOFI interferometer compared to the heterodyne interferometer. LOFI interferometry is demonstrated to show higher performance than heterodyne interferometry for a wide range of laser powers and detection levels of noise. The experimental results are in good agreement with the theoretical predictions.
Nakajima, Yoshiaki; Inaba, Hajime; Hosaka, Kazumoto; Minoshima, Kaoru; Onae, Atsushi; Yasuda, Masami; Kohno, Takuya; Kawato, Sakae; Kobayashi, Takao; Katsuyama, Toshio; Hong, Feng-Lei
2010-01-18
We demonstrate that fiber-based frequency combs with multi-branch configurations can transfer both linewidth and frequency stability to another wavelength at the millihertz level. An intra-cavity electro-optic modulator is employed to obtain a broad servo bandwidth for repetition rate control. We investigate the relative linewidths between two combs using a stable continuous-wave laser as a common reference to stabilize the repetition rate frequencies in both combs. The achieved energy concentration to the carrier of the out-of-loop beat between the two combs was 99% and 30% at a bandwidth of 1 kHz and 7.6 mHz, respectively. The frequency instability of the comb was 3.7x10(-16) for a 1 s averaging time, improving to 5-8x10(-19) for 10000 s. We show that the frequency noise in the out-of-loop beat originates mainly from phase noise in branched optical fibers.
Coordinated Beating of Algal Flagella is Mediated by Basal Coupling
NASA Astrophysics Data System (ADS)
Wan, Kirsty; Goldstein, Raymond
Cilia or flagella often exhibit synchronized behavior. This includes phase-locking, as seen in Chlamydomonas, and metachronal wave formation in the respiratory cilia of higher organisms. Since the observations by Gray and Rothschild of phase synchrony of nearby swimming spermatozoa, it has been a working hypothesis that synchrony arises from hydrodynamic interactions between beating filaments. Recent work on the dynamics of physically separated pairs of flagella isolated from the multicellular alga Volvox has shown that hydrodynamic coupling alone is sufficient for synchrony. However, the situation is more complex when considering multiple flagella on a single cell. We suggest that a mechanism, internal to the cell, provides an additional flagellar coupling. For instance, flagella of Chlamydomonas mutants deficient in filamentary connections between basal bodies are found to display markedly different synchronization from the wildtype. Diverse flagellar coordination strategies found in quadri-, octo- and hexadecaflagellates reveal further evidence that intracellular couplings between flagellar basal bodies compete with hydrodynamic interactions to determine the precise form of flagellar synchronization in unicellular algae.
Beating Darwin-Bragg losses in lab-based ultrafast x-ray experiments
Fullagar, Wilfred K.; Uhlig, Jens; Mandal, Ujjwal; Kurunthu, Dharmalingam; El Nahhas, Amal; Tatsuno, Hideyuki; Honarfar, Alireza; Parnefjord Gustafsson, Fredrik; Sundström, Villy; Palosaari, Mikko R. J.; Kinnunen, Kimmo M.; Maasilta, Ilari J.; Miaja-Avila, Luis; O'Neil, Galen C.; Joe, Young Il; Swetz, Daniel S.; Ullom, Joel N.
2017-01-01
The use of low temperature thermal detectors for avoiding Darwin-Bragg losses in lab-based ultrafast experiments has begun. An outline of the background of this new development is offered, showing the relevant history and initiative taken by this work. PMID:28396880
Visual tuning and metrical perception of realistic point-light dance movements.
Su, Yi-Huang
2016-03-07
Humans move to music spontaneously, and this sensorimotor coupling underlies musical rhythm perception. The present research proposed that, based on common action representation, different metrical levels as in auditory rhythms could emerge visually when observing structured dance movements. Participants watched a point-light figure performing basic steps of Swing dance cyclically in different tempi, whereby the trunk bounced vertically at every beat and the limbs moved laterally at every second beat, yielding two possible metrical periodicities. In Experiment 1, participants freely identified a tempo of the movement and tapped along. While some observers only tuned to the bounce and some only to the limbs, the majority tuned to one level or the other depending on the movement tempo, which was also associated with individuals' preferred tempo. In Experiment 2, participants reproduced the tempo of leg movements by four regular taps, and showed a slower perceived leg tempo with than without the trunk bouncing simultaneously in the stimuli. This mirrors previous findings of an auditory 'subdivision effect', suggesting the leg movements were perceived as beat while the bounce as subdivisions. Together these results support visual metrical perception of dance movements, which may employ similar action-based mechanisms to those underpinning auditory rhythm perception.
NASA Astrophysics Data System (ADS)
Baglivo, Fabricio Hugo; Arini, Pedro David
2011-12-01
Electrocardiographic repolarization abnormalities can be detected by Principal Components Analysis of the T-wave. In this work we studied the efect of signal averaging on the mean value and reproducibility of the ratio of the 2nd to the 1st eigenvalue of T-wave (T21W) and the absolute and relative T-wave residuum (TrelWR and TabsWR) in the ECG during ischemia induced by Percutaneous Coronary Intervention. Also, the intra-subject and inter-subject variability of T-wave parameters have been analyzed. Results showed that TrelWR and TabsWR evaluated from the average of 10 complexes had lower values and higher reproducibility than those obtained from 1 complex. On the other hand T21W calculated from 10 complexes did not show statistical diferences versus the T21W calculated on single beats. The results of this study corroborate that, with a signal averaging technique, the 2nd and the 1st eigenvalue are not afected by noise while the 4th to 8th eigenvalues are so much afected by this, suggesting the use of the signal averaged technique before calculation of absolute and relative T-wave residuum. Finally, we have shown that T-wave morphology parameters present high intra-subject stability.
Locomotion of Paramecium in patterned environments
NASA Astrophysics Data System (ADS)
Park, Eun-Jik; Eddins, Aja; Kim, Junil; Yang, Sung; Jana, Saikat; Jung, Sunghwan
2011-10-01
Ciliary organisms like Paramecium Multimicronucleatum locomote by synchronized beating of cilia that produce metachronal waves over their body. In their natural environments they navigate through a variety of environments especially surfaces with different topology. We study the effects of wavy surfaces patterned on the PDMS channels on the locomotive abilities of Paramecium by characterizing different quantities like velocity amplitude and wavelength of the trajectories traced. We compare this result with the swimming characteristics in straight channels and draw conclusions about the effects of various patterned surfaces.
THz generation by laser coupling to carbon nanotube array
NASA Astrophysics Data System (ADS)
Malik, Rakhee; Uma, R.
2018-01-01
A viable scheme of THz radiation generation by beating of two lasers ( ω1 , k→ 1 ; ω2 , k→ 2 ) in a nanotube array, mounted on a dielectric substrate, is proposed and studied. The free electrons of the nanotubes acquire a large oscillatory velocity and experience a beat frequency ponderomotive force that turns nanotubes into oscillating dipole antennae emitting THz radiation. The THz power peaks in directions where a phase difference between fields due to successive nanotubes is integral multiple of 2 π . The THz power is large when the beat frequency equals ωp/√{2 } (where ωp is the electron plasma frequency) and surface plasmon resonance occurs. For our set of laser and carbon nanotube parameters, the generated THz is about 0.1 kW for CO2 laser power of 10 GW and pulse length of a few picoseconds.
Performance evaluation of an improved fish robot actuated by piezoceramic actuators
NASA Astrophysics Data System (ADS)
Nguyen, Q. S.; Heo, S.; Park, H. C.; Byun, D.
2010-03-01
This paper presents an improved fish robot actuated by four lightweight piezocomposite actuators. Our newly developed actuation mechanism is simple to fabricate because it works without gears. With the new actuation mechanism, the fish robot has a 30% smaller cross section than our previous model. Performance tests of the fish robot in water were carried out to measure the tail-beat angle, the thrust force, the swimming speed for various tail-beat frequencies from 1 to 5 Hz and the turning radius at the optimal frequency. The maximum swimming speed of the fish robot is 7.7 cm s - 1 at a tail-beat frequency of 3.9 Hz. A turning experiment shows that the swimming direction of the fish robot can be controlled by changing the duty ratio of the driving voltage; the fish robot has a turning radius of 0.41 m for a left turn and 0.68 m for a right turn.
LANGMUIR WAVE DECAY IN INHOMOGENEOUS SOLAR WIND PLASMAS: SIMULATION RESULTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krafft, C.; Volokitin, A. S.; Krasnoselskikh, V. V., E-mail: catherine.krafft@u-psud.fr
2015-08-20
Langmuir turbulence excited by electron flows in solar wind plasmas is studied on the basis of numerical simulations. In particular, nonlinear wave decay processes involving ion-sound (IS) waves are considered in order to understand their dependence on external long-wavelength plasma density fluctuations. In the presence of inhomogeneities, it is shown that the decay processes are localized in space and, due to the differences between the group velocities of Langmuir and IS waves, their duration is limited so that a full nonlinear saturation cannot be achieved. The reflection and the scattering of Langmuir wave packets on the ambient and randomly varying density fluctuationsmore » lead to crucial effects impacting the development of the IS wave spectrum. Notably, beatings between forward propagating Langmuir waves and reflected ones result in the parametric generation of waves of noticeable amplitudes and in the amplification of IS waves. These processes, repeated at different space locations, form a series of cascades of wave energy transfer, similar to those studied in the frame of weak turbulence theory. The dynamics of such a cascading mechanism and its influence on the acceleration of the most energetic part of the electron beam are studied. Finally, the role of the decay processes in the shaping of the profiles of the Langmuir wave packets is discussed, and the waveforms calculated are compared with those observed recently on board the spacecraft Solar TErrestrial RElations Observatory and WIND.« less
Work Hardening Behavior of 1020 Steel During Cold-Beating Simulation
NASA Astrophysics Data System (ADS)
CUI, Fengkui; LING, Yuanfei; XUE, Jinxue; LIU, Jia; LIU, Yuhui; LI, Yan
2017-03-01
The present research of cold-beating formation mainly focused on roller design and manufacture, kinematics, constitutive relation, metal flow law, thermo-mechanical coupling, surface micro-topography and microstructure evolution. However, the research on surface quality and performance of workpieces in the process of cold-beating is rare. Cold-beating simulation experiment of 1020 steel is conducted at room temperature and strain rates ranging from 2000 to 4000 s-1 base on the law of plastic forming. According to the experimental data, the model of strain hardening of 1020 steel is established, Scanning Electron Microscopy(SEM) is conducted, the mechanism of the work hardening of 1020 steel is clarified by analyzing microstructure variation of 1020 steel. It is found that the strain rate hardening effect of 1020 steel is stronger than the softening effect induced by increasing temperatures, the process of simulation cold-beating cause the grain shape of 1020 steel significant change and microstructure elongate significantly to form a fibrous tissue parallel to the direction of deformation, the higher strain rate, the more obvious grain refinement and the more hardening effect. Additionally, the change law of the work hardening rate is investigated, the relationship between dislocation density and strain, the relationship between work hardening rate and dislocation density is obtained. Results show that the change trend of the work hardening rate of 1020 steel is divided into two stages, the work hardening rate decreases dramatically in the first stage and slowly decreases in the second stage, finally tending toward zero. Dislocation density increases with increasing strain and strain rate, work hardening rate decreases with increasing dislocation density. The research results provide the basis for solving the problem of improving the surface quality and performance of workpieces under cold-beating formation of 1020 steel.
A comparison of auditory evoked potentials to acoustic beats and to binaural beats.
Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi
2010-04-01
The purpose of this study was to compare cortical brain responses evoked by amplitude modulated acoustic beats of 3 and 6 Hz in tones of 250 and 1000 Hz with those evoked by their binaural beats counterparts in unmodulated tones to indicate whether the cortical processes involved differ. Event-related potentials (ERPs) were recorded to 3- and 6-Hz acoustic and binaural beats in 2000 ms duration 250 and 1000 Hz tones presented with approximately 1 s intervals. Latency, amplitude and source current density estimates of ERP components to beats-evoked oscillations were determined and compared across beat types, beat frequencies and base (carrier) frequencies. All stimuli evoked tone-onset components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude in response to acoustic than to binaural beats, to 250 than to 1000 Hz base frequency and to 3 Hz than to 6 Hz beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left temporal lobe areas. Differences between estimated sources of potentials to acoustic and binaural beats were not significant. The perceptions of binaural beats involve cortical activity that is not different than acoustic beats in distribution and in the effects of beat- and base frequency, indicating similar cortical processing. Copyright 2010 Elsevier B.V. All rights reserved.
Jesmin, Syeda S
2015-01-01
One-third of the women worldwide experience intimate partner violence (IPV) that increases their vulnerability to both short- and long-term physical, sexual, reproductive, and mental health problems. Surprisingly, IPV is justified by many women globally. Although the IPV literature to date is mostly focused on risk factors associated with actual occurrences, little is known on attitudinal acceptance of such violence. Also, despite the growing scholarship of community influence and health link, IPV research has relatively overlooked the effects of norms at the community level. Using a representative national sample of 13,611 married women in Bangladesh, this study examined the association of community attitudes and women's individual attitudes toward wife beating. The results revealed that women living in communities with permissive attitudes toward wife beating were more likely to justify husbands' beating (OR=4.5). Women married at a younger age, who had less than primary-level education, lived in households categorized as poor or middle class, and did not consume media appeared to be at higher risk for justifying wife beating. This research adds to a growing research body on community influences on health by examining IPV attitudes and community norms link.
Effects of Kindermusik training on infants' rhythmic enculturation.
Gerry, David W; Faux, Ashley L; Trainor, Laurel J
2010-05-01
Phillips-Silver and Trainor (2005) demonstrated a link between movement and the metrical interpretation of rhythm patterns in 7-month-old infants. Infants bounced on every second beat of a rhythmic pattern with no auditory accents later preferred to listen to an accented version of the pattern with accents every second beat (duple or march meter), whereas infants bounced on every third beat of the same rhythmic pattern preferred to listen to a version with accents every third beat (triple or waltz meter). The present study compared infants participating in Kindermusik classes with infants not participating in music classes. In Kindermusik classes infants receive enriched experience moving to music. Following Western musical norms, the majority of the music samples in the classes are in duple meter. During the preference test, Kindermusik infants listened longer overall, indicating heightened interest in musical rhythms. Both groups listened longer to the accented version that matched how they had been bounced, but only the Kindermusik group showed a stronger preference in the case of duple bouncing than in the case of triple bouncing. We conclude that musical classes for infants can accelerate the development of culture-specific metrical perception.
V.M, Fernandes de Lima; W, Hanke
2014-01-01
In preclinical neuropharmacological research, molecular, cell-based, and systems using animals are well established. On the tissue level the situation is less comfortable, although during the last decades some effort went into establishing such systems, i.e. using slices of the vertebrate brain together with optical and electrophysiological techniques. However, these methods are neither fast, nor can they be automated or upscaled. By contrast, the chicken retina can be used as a suitable model. It is easy accessible and can be kept alive in vitro for hours up to days. Due to its structure, in addition the retina displays remarkable intrinsic optical signals, which can be easily used in experiments. Also to electrophysiological methods the retina is well accessible. In excitable tissue, to which the brain and the retina belong, propagating excitation waves can be expected, and the spreading depression is such a phenomenon. It has been first observed in the forties of the last century. Later, Martins-Ferreira established it in the chicken retina (retinal spreading depression or RSD). The electrophysiological characteristics of it are identical with those of the cortical SD. The metabolic differences are known and can be taken into account. The experimental advantage of the RSD compared to the cortical SD is the pronounced intrinsic optical signal (IOS) associated with the travelling wave. This is due to the maximum transparency of retinal tissue in the functional state; thus any physiological event will change it markedly and therefore can be easily seen even by naked eye. The theory can explain wave spread in one (action potentials), two (RSDs) and three dimensions (one heart beat). In this review we present the experimental and the excitable media context for the data interpretation using as example the cholinergic pharmacology in relation to functional syndromes. We also discuss the intrinsic optical signal and how to use it in pre-clinical research. PMID:25426010
Effects on transionospheric HF propagation observed by ISIS at middle and auroral latitudes
NASA Astrophysics Data System (ADS)
James, G.
During the months of May through July 1978, an experiment on transionospheric HF propagation was carried out using a transmitter at Ottawa and the sounder receivers of the ISIS-I and ISIS-II spacecraft. Fixed- and synchronous swept-frequency recordings were made. Over 100 ISIS-II passes were successfully recorded at 9.303 MHz, the highest fixed frequency of receiver operation. Several tens of these passes have been analyzed in an attempt to establish the salient characteristics of the propagation. From these characteristics, the goal is to improve understanding of the processes experienced by waves passing through the ionosphere, e.g., focusing or scattering. This research supports planning for coordinated ground-space radio experiments in the upcoming Enhanced Polar Outflow Probe satellite mission, to be flown for the Canadian Space Agency. Swept-frequency ionograms interleaved with the aforementioned fixed-frequency measurements allowed two-dimensional density distributions to be modeled in altitude and latitude. Computer code was developed for three-dimensional ray tracing. A Newton's-iteration algorithm was used for efficient searches for solution rays that connect the transmitter with the position of the satellite at any time along its path. The latitudinal extent of the zone irradiated at ISIS-II altitude thus computed is approximately as observed, albeit sensitively dependent upon north-south density gradients. Within this "iris" of accessibility, the peak intensity of waves recorded at the spacecraft is within 10 dB of that found with a link calculation based on ray optics. Density inhomogeneities influence the transmitted O and X mode waves, in various ways. Poleward rays result in dispersed pulses, indicating quasi-perpendicular propagation that is forward scattered. Toward the equator, propagation directions come to within about 10 of the magnetic-field axis. Equatorward pulses are comparatively sharp and occasionally exhibit periodic fades with beat frequencies between about 1 and 4 Hz. Features of the fades indicate that focusing of rays is a better explanation for the fades than diffraction.
An Optical Trap for Relativistic Plasma
NASA Astrophysics Data System (ADS)
Zhang, Ping
2002-11-01
Optical traps have achieved remarkable success recently in confining ultra-cold matter.Traps capable of confining ultra-hot matter, or plasma, have also been built for applications such as basic plasma research and thermonuclear fusion. For instance, low-density plasmas with temperature less than 1 keV have been confined with static magnetic fields in Malmberg-Penning traps. Low-density 10-50 keV plasmas are confined in magnetic mirrors and tokamaks. High density plasmas have been trapped in optical traps with kinetic energies up to 10 keV [J. L. Chaloupka and D. D. Meyerhofer, Phys. Rev. Lett. 83, 4538 (1999)]. We present the results of experiment, theory and numerical simulation on an optical trap capable of confining relativistic plasma. A stationary interference grating with submicron spacing is created when two high-power (terawatt) laser pulses of equal wavelength (1-micron) are focused from orthogonal directions to the same point in space and time in high density underdense plasma. Light pressure gradients bunch electrons into sheets located at the minima of the interference pattern. The density of the bunched electrons is found to be up to ten times the background density, which is orders-of-magnitude above that previously reported for other optical traps or plasma waves. The amplitudes and frequencies of multiple satellites in the scattered spectrum also indicate the presence of a highly nonlinear ion wave and an electron temperature about 100 keV. Energy transfer from the stronger beam to the weaker beam is also observed. Potential applications include a test-bed for detailed studies of relativistic nonlinear scattering, a positron source and an electrostatic wiggler. This research is also relevant to fast igniter fusion or ion acceleration experiments, in which laser pulses with intensities comparable to those used in the experiment may also potentially beat [Y. Sentoku, et al., Appl. Phys. B 74, 207215 (2002)]. The details of a specific application, the injection of electrons into laser-driven plasma waves, will also be presented. With crossed beams, the energy of a laser-accelerated electron beam is increased and its emittance is decreased compared with a single beam, potentially paving the way towards an all-optical monoenergetic electron injector.
Speckle variance optical coherence tomography of blood flow in the beating mouse embryonic heart.
Grishina, Olga A; Wang, Shang; Larina, Irina V
2017-05-01
Efficient separation of blood and cardiac wall in the beating embryonic heart is essential and critical for experiment-based computational modelling and analysis of early-stage cardiac biomechanics. Although speckle variance optical coherence tomography (SV-OCT) relying on calculation of intensity variance over consecutively acquired frames is a powerful approach for segmentation of fluid flow from static tissue, application of this method in the beating embryonic heart remains challenging because moving structures generate SV signal indistinguishable from the blood. Here, we demonstrate a modified four-dimensional SV-OCT approach that effectively separates the blood flow from the dynamic heart wall in the beating mouse embryonic heart. The method takes advantage of the periodic motion of the cardiac wall and is based on calculation of the SV signal over the frames corresponding to the same phase of the heartbeat cycle. Through comparison with Doppler OCT imaging, we validate this speckle-based approach and show advantages in its insensitiveness to the flow direction and velocity as well as reduced influence from the heart wall movement. This approach has a potential in variety of applications relying on visualization and segmentation of blood flow in periodically moving structures, such as mechanical simulation studies and finite element modelling. Picture: Four-dimensional speckle variance OCT imaging shows the blood flow inside the beating heart of an E8.5 mouse embryo. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Jackson, F. C.
1979-01-01
Two simple microwave radar techniques that are potentially capable of providing routine satellite measurements of the directional spectrum of ocean waves were developed. One technique, the short pulse technique, makes use of very short pulses to resolve ocean surface wave contrast features in the range direction; the other technique, the two frequency correlation technique makes use of coherency in the transmitted waveform to detect the large ocean wave contrast modulation as a beat or mixing frequency in the power backscattered at two closely separated microwave frequencies. A frequency domain analysis of the short pulse and two frequency systems shows that the two measurement systems are essentially duals; they each operate on the generalized (three frequency) fourth-order statistical moment of the surface transfer function in different, but symmetrical ways, and they both measure the same directional contrast modulation spectrum. A three dimensional physical optics solution for the fourth-order moment was obtained for backscatter in the near vertical, specular regime, assuming Gaussian surface statistics.
Son, Minjung; Park, Kyu Hyung; Yoon, Min-Chul; Kim, Pyosang; Kim, Dongho
2015-06-18
Broadband laser pulses with ultrashort duration are capable of triggering impulsive excitation of the superposition of vibrational eigenstates, giving rise to quantum beating signals originating from coherent wave packet motions along the potential energy surface. In this work, coherent vibrational wave packet dynamics of an N,N'-bis(2,6-dimethylphenyl)perylene bisimide (DMP-PBI) were investigated by femtosecond broadband pump-probe spectroscopy which features fast and balanced data acquisition with a wide spectral coverage of >200 nm. Clear modulations were observed in the envelope of the stimulated emission decay profiles of DMP-PBI with the oscillation frequencies of 140 and 275 cm(-1). Fast Fourier transform analysis of each oscillatory mode revealed characteristic phase jumps near the maxima of the steady-state fluorescence, indicating that the observed vibrational coherence originates from an excited-state wave packet motion. Quantum calculations of the normal modes at the low-frequency region suggest that low-frequency C-C (C═C) stretching motions accompanied by deformation of the dimethylphenyl substituents are responsible for the manifestation of such coherent wave packet dynamics.
Listeners feel the beat: entrainment to English and French speech rhythms.
Lidji, Pascale; Palmer, Caroline; Peretz, Isabelle; Morningstar, Michele
2011-12-01
Can listeners entrain to speech rhythms? Monolingual speakers of English and French and balanced English-French bilinguals tapped along with the beat they perceived in sentences spoken in a stress-timed language, English, and a syllable-timed language, French. All groups of participants tapped more regularly to English than to French utterances. Tapping performance was also influenced by the participants' native language: English-speaking participants and bilinguals tapped more regularly and at higher metrical levels than did French-speaking participants, suggesting that long-term linguistic experience with a stress-timed language can differentiate speakers' entrainment to speech rhythm.
ECG fiducial point extraction using switching Kalman filter.
Akhbari, Mahsa; Ghahjaverestan, Nasim Montazeri; Shamsollahi, Mohammad B; Jutten, Christian
2018-04-01
In this paper, we propose a novel method for extracting fiducial points (FPs) of the beats in electrocardiogram (ECG) signals using switching Kalman filter (SKF). In this method, according to McSharry's model, ECG waveforms (P-wave, QRS complex and T-wave) are modeled with Gaussian functions and ECG baselines are modeled with first order auto regressive models. In the proposed method, a discrete state variable called "switch" is considered that affects only the observation equations. We denote a mode as a specific observation equation and switch changes between 7 modes and corresponds to different segments of an ECG beat. At each time instant, the probability of each mode is calculated and compared among two consecutive modes and a path is estimated, which shows the relation of each part of the ECG signal to the mode with the maximum probability. ECG FPs are found from the estimated path. For performance evaluation, the Physionet QT database is used and the proposed method is compared with methods based on wavelet transform, partially collapsed Gibbs sampler (PCGS) and extended Kalman filter. For our proposed method, the mean error and the root mean square error across all FPs are 2 ms (i.e. less than one sample) and 14 ms, respectively. These errors are significantly smaller than those obtained using other methods. The proposed method achieves lesser RMSE and smaller variability with respect to others. Copyright © 2018 Elsevier B.V. All rights reserved.
A Magnetic Plethysmograph Probe for Local Pulse Wave Velocity Measurement.
P M, Nabeel; Joseph, Jayaraj; Sivaprakasam, Mohanasankar
2017-10-01
We present the design and experimental validation of an arterial compliance probe with dual magnetic plethysmograph (MPG) transducers for local pulse wave velocity (PWV) measurement. The MPG transducers (positioned at 23 mm distance apart) utilizes Hall-effect sensors and permanent magnets for arterial blood pulse detection. The MPG probe was initially validated on an arterial flow phantom using a reference method. Further, 20 normotensive subjects (14 males, age = 24 ± 3.5 years) were studied under two different physical conditions: 1) Physically relaxed condition, 2) Postexercise condition. Local PWV was measured from the left carotid artery using the MPG probe. Brachial blood pressure (BP) was measured to investigate the correlation of BP with local PWV. The proposed MPG arterial compliance probe was capable of detecting high-fidelity blood pulse waveforms. Reliable local pulse transit time estimates were assessed by the developed measurement system. Beat-by-beat local PWV was measured from multiple subjects under different physical conditions. A profound increment was observed in the carotid local PWV for all subjects after exercise (average increment = 0.42 ± 0.22 m/s). Local PWV values and brachial BP parameters were significantly correlated (r ≥ 0.72), except for pulse pressure (r = 0.42). MPG arterial compliance probe for local PWV measurement was validated. Carotid local PWV measurement, its variations due to physical exercise and correlation with BP levels were examined during the in vivo study. A novel dual MPG probe for local PWV measurement and potential use in cuffless BP measurement.
Identification of a Group's Physiological Synchronization with Earth's Magnetic Field.
Timofejeva, Inga; McCraty, Rollin; Atkinson, Mike; Joffe, Roza; Vainoras, Alfonsas; Alabdulgader, Abdullah A; Ragulskis, Minvydas
2017-09-01
A new analysis technique for the evaluation of the degree of synchronization between the physiological state of a group of people and changes in the Earth's magnetic field based on their cardiac inter-beat intervals was developed and validated. The new analysis method was then used to identify clusters of similar synchronization patterns in a group of 20 individuals over a two-week period. The algorithm for the identification of slow wave dynamics for every person was constructed in order to determine meaningful interrelationships between the participants and the local magnetic field data. The results support the hypothesis that the slow wave rhythms in heart rate variability can synchronize with changes in local magnetic field data, and that the degree of synchronization is affected by the quality of interpersonal relationships.
Dance and Music in “Gangnam Style”: How Dance Observation Affects Meter Perception
Lee, Kyung Myun; Barrett, Karen Chan; Kim, Yeonhwa; Lim, Yeoeun; Lee, Kyogu
2015-01-01
Dance and music often co-occur as evidenced when viewing choreographed dances or singers moving while performing. This study investigated how the viewing of dance motions shapes sound perception. Previous research has shown that dance reflects the temporal structure of its accompanying music, communicating musical meter (i.e. a hierarchical organization of beats) via coordinated movement patterns that indicate where strong and weak beats occur. Experiments here investigated the effects of dance cues on meter perception, hypothesizing that dance could embody the musical meter, thereby shaping participant reaction times (RTs) to sound targets occurring at different metrical positions.In experiment 1, participants viewed a video with dance choreography indicating 4/4 meter (dance condition) or a series of color changes repeated in sequences of four to indicate 4/4 meter (picture condition). A sound track accompanied these videos and participants reacted to timbre targets at different metrical positions. Participants had the slowest RT’s at the strongest beats in the dance condition only. In experiment 2, participants viewed the choreography of the horse-riding dance from Psy’s “Gangnam Style” in order to examine how a familiar dance might affect meter perception. Moreover, participants in this experiment were divided into a group with experience dancing this choreography and a group without experience. Results again showed slower RTs to stronger metrical positions and the group with experience demonstrated a more refined perception of metrical hierarchy. Results likely stem from the temporally selective division of attention between auditory and visual domains. This study has implications for understanding: 1) the impact of splitting attention among different sensory modalities, and 2) the impact of embodiment, on perception of musical meter. Viewing dance may interfere with sound processing, particularly at critical metrical positions, but embodied familiarity with dance choreography may facilitate meter awareness. Results shed light on the processing of multimedia environments. PMID:26308092
Quasi-Decadal Oscillations Generated by the QBO
NASA Technical Reports Server (NTRS)
Mayr, Hans G.; Mengel, J. G.; Drob, D. P.; Porter, H. S.; Bhartia, P. K. (Technical Monitor)
2001-01-01
Quasi-decadal oscillations (QDO) have been observed in the stratosphere and have been linked to the equatorial Quasi-Biennial Oscillation (QBO) and to the 11-year solar activity cycle. With the use of a 2D version of our Numerical Spectral Model (NSM) that incorporates Hines'Doppler Spread Parameterization (DSP) for gravity waves (GW), we demonstrate that beat periods between 9 and I I years can be generated by the QBO as it interacts through GW filtering with the Annual Oscillation (AO) and Semi-annual Oscillation (SAO). Results are discussed from computations covering up to 50 years, and our analyses leads to the following conclusions. The QDO as a stand-alone signature is largely confined to the upper mesosphere. Its largest signature appears in the form of amplitude modulations of the QBO, AO and SAO, and these extend into the lower stratosphere. The downward control that characterizes the QBO apparently comes into play, and the longer time constants for diffusion and radiative loss at lower altitudes facilitate the QDO response. Although excited by the QBO, which is confined to low latitudes, the QDO is shown to extend to high latitudes. The effect is particularly large for the QBO with period around 33.5 month (near the upper limit of observations), which interacts with the SAO to produce a hemispherically symmetric QDO. Our analysis indicates that the QDO is transferred to high latitudes by the meridional circulation, which prominently exhibits this periodicity particularly in the amplitude modulation of the AO. The propensity for beat periods around 10 years may help to increase significantly the efficiency for generating solar cycle signatures in the atmosphere, and we discuss numerical experiments related to that.
Continuous-wave optical parametric oscillators on their way to the terahertz range
NASA Astrophysics Data System (ADS)
Sowade, Rosita; Breunig, Ingo; Kiessling, Jens; Buse, Karsten
2010-02-01
Continuous-wave optical parametric oscillators (OPOs) are known to be working horses for spectroscopy in the near- and mid-infrared. However, strong absorption in nonlinear media like lithium niobate complicates the generation of far-infrared light. This absorption leads to pump thresholds vastly exceeding the power of standard pump lasers. Our first approach was, therefore, to combine the established technique of photomixing with optical parametric oscillators. Here, two OPOs provide one wave each, with a tunable difference frequency. These waves are combined to a beat signal as a source for photomixers. Terahertz radiation between 0.065 and 1.018 THz is generated with powers in the order of nanowatts. To overcome the upper frequency limit of the opto-electronic photomixers, terahertz generation has to rely entirely on optical methods. Our all-optical approach, getting around the high thresholds for terahertz generation, is based on cascaded nonlinear processes: the resonantly enhanced signal field, generated in the primary parametric process, is intense enough to act as the pump for a secondary process, creating idler waves with frequencies in the terahertz regime. The latter ones are monochromatic and tunable with detected powers of more than 2 μW at 1.35 THz. Thus, continuous-wave optical parametric oscillators have entered the field of terahertz photonics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bellgraph, Brian J.; McMichael, Geoffrey A.; Mueller, Robert P.
2010-01-01
The behaviours of juvenile Chinook salmon Oncorhynchus tshawytscha were evaluated during a temperature increase from 8.8 to 23.2°C, which was designed to simulate unique thermal conditions present in a hydroelectric reservoir. The percent of fish with an active swimming behaviour increased from 26 to 93 % and mean opercular beat rates increased from 76 to 159 beats per minute between basal and maximum temperatures. Fish equilibrium did not change significantly throughout the experiment and relatively little mortality (12 %) occurred. Thermal stress is likely incurred by juvenile salmon experiencing a temperature change of this magnitude; however, stress induced in thismore » study was primarily sublethal. Behavioural changes accompanying thermal stress (e.g., erratic swimming) may increase predation potential in the wild despite being sublethal during laboratory experiments.« less
NASA Astrophysics Data System (ADS)
Sauer, Konrad; Malaspina, David M.; Pulupa, Marc; Salem, Chadi S.
2017-07-01
Langmuir amplitude modulation in association with type III radio bursts is a well-known phenomenon since the beginning of space observations. It is commonly attributed to the superposition of beam-excited Langmuir waves and their backscattered counterparts as a result of parametric decay. The dilemma, however, is the discrepancy between fast beam relaxation and long-lasting Langmuir wave activity. Instead of starting with an unstable electron beam, our focus in this paper is on the nonlinear response of Langmuir oscillations that are driven after beam stabilization by the still persisting current of the (stable) two-electron plasma. The velocity distribution function of the second population forms a plateau (index h) with a point at which ∂fh/∂v ˜0 associated with weak damping over a more or less extended wave number range k. As shown by particle-in-cell simulations, this so-called plateau plasma drives primarily Langmuir oscillations at the plasma frequency (ωe) with k = 0 over long times without remarkable change of the distribution function. These Langmuir oscillations act as a pump wave for parametric decay by which an electron-acoustic wave slightly below ωe and a counterstreaming ion-acoustic wave are generated. Both high-frequency waves have nearly the same amplitude, which is given by the product of plateau density and velocity. Beating of these two wave types leads to pronounced Langmuir amplitude modulation, in reasonable agreement with solar wind and terrestrial foreshock observations made by the Wind spacecraft.
Fast T Wave Detection Calibrated by Clinical Knowledge with Annotation of P and T Waves.
Elgendi, Mohamed; Eskofier, Bjoern; Abbott, Derek
2015-07-21
There are limited studies on the automatic detection of T waves in arrhythmic electrocardiogram (ECG) signals. This is perhaps because there is no available arrhythmia dataset with annotated T waves. There is a growing need to develop numerically-efficient algorithms that can accommodate the new trend of battery-driven ECG devices. Moreover, there is also a need to analyze long-term recorded signals in a reliable and time-efficient manner, therefore improving the diagnostic ability of mobile devices and point-of-care technologies. Here, the T wave annotation of the well-known MIT-BIH arrhythmia database is discussed and provided. Moreover, a simple fast method for detecting T waves is introduced. A typical T wave detection method has been reduced to a basic approach consisting of two moving averages and dynamic thresholds. The dynamic thresholds were calibrated using four clinically known types of sinus node response to atrial premature depolarization (compensation, reset, interpolation, and reentry). The determination of T wave peaks is performed and the proposed algorithm is evaluated on two well-known databases, the QT and MIT-BIH Arrhythmia databases. The detector obtained a sensitivity of 97.14% and a positive predictivity of 99.29% over the first lead of the validation databases (total of 221,186 beats). We present a simple yet very reliable T wave detection algorithm that can be potentially implemented on mobile battery-driven devices. In contrast to complex methods, it can be easily implemented in a digital filter design.
Alignment strategies for the entrainment of music and movement rhythms.
Moens, Bart; Leman, Marc
2015-03-01
Theories of entrainment assume that spontaneous entrainment emerges from dynamic laws that operate via mediators on interactions, whereby entrainment is facilitated if certain conditions are fulfilled. In this study, we show that mediators can be built that affect the entrainment of human locomotion to music. More specifically, we built D-Jogger, a music player that functions as a mediator between music and locomotion rhythms. The D-Jogger makes it possible to manipulate the timing differences between salient moments of the rhythms (beats and footfalls) through the manipulation of the musical period and phase, which affect the condition in which entrainment functions. We conducted several experiments to explore different strategies for manipulating the entrainment of locomotion and music. The results of these experiments showed that spontaneous entrainment can be manipulated, thereby suggesting different strategies on how to embark. The findings furthermore suggest a distinction among different modalities of entrainment: finding the beat (the most difficult part of entrainment), keeping the beat (easier, as a temporal scheme has been established), and being in phase (no entrainment is needed because the music is always adapted to the human rhythm). This study points to a new avenue of research on entrainment and opens new perspectives for the neuroscience of music. © 2014 New York Academy of Sciences.
Visual tuning and metrical perception of realistic point-light dance movements
Su, Yi-Huang
2016-01-01
Humans move to music spontaneously, and this sensorimotor coupling underlies musical rhythm perception. The present research proposed that, based on common action representation, different metrical levels as in auditory rhythms could emerge visually when observing structured dance movements. Participants watched a point-light figure performing basic steps of Swing dance cyclically in different tempi, whereby the trunk bounced vertically at every beat and the limbs moved laterally at every second beat, yielding two possible metrical periodicities. In Experiment 1, participants freely identified a tempo of the movement and tapped along. While some observers only tuned to the bounce and some only to the limbs, the majority tuned to one level or the other depending on the movement tempo, which was also associated with individuals’ preferred tempo. In Experiment 2, participants reproduced the tempo of leg movements by four regular taps, and showed a slower perceived leg tempo with than without the trunk bouncing simultaneously in the stimuli. This mirrors previous findings of an auditory ‘subdivision effect’, suggesting the leg movements were perceived as beat while the bounce as subdivisions. Together these results support visual metrical perception of dance movements, which may employ similar action-based mechanisms to those underpinning auditory rhythm perception. PMID:26947252
Optimal development of matrix elasticity
Majkut, Stephanie; Idema, Timon; Swift, Joe; Krieger, Christine; Liu, Andrea; Discher, Dennis E.
2014-01-01
Summary In development and differentiation, morphological changes often accompany mechanical changes [1], but it is unclear if or when cells in embryos sense tissue elasticity. The earliest embryo is uniformly pliable while adult tissues vary widely in mechanics from soft brain and stiff heart to rigid bone [2], but the sensitivity of cells to microenvironment elasticity is debated [3]. Regenerative cardiology provides strong motivation because rigid post-infarct regions limit pumping by the adult heart [4]. Here we focus on embryonic heart and isolated cardiomyocytes, which both beat spontaneously. Tissue elasticity, Et, increases daily for heart to 1-2 kiloPascal by embryonic day-4 (E4), and although this is ∼10-fold softer than adult heart, the beating contractions of E4-cardiomyocytes prove optimal at ∼Et,E4 both in vivo and in vitro. Proteomics reveals daily increases in a small subset of proteins, namely collagen plus cardiac-specific excitation-contraction proteins. Rapid softening of the heart's matrix with collagenase or stiffening it with enzymatic crosslinking suppresses beating. Sparsely cultured E4-cardiomyocytes on collagen-coated gels likewise show maximal contraction on matrices with native E4 stiffness, highlighting cell-intrinsic mechanosensitivity. While an optimal elasticity for striation proves consistent with the mathematics of force-driven sarcomere registration, contraction wave-speed is linear in Et as theorized for Excitation-Contraction Coupled to Matrix Elasticity. Mechanosensitive stem cell cardiogenesis helps generalize tissue results, which demonstrate how myosin-II organization and contractile function is optimally matched to the load presented by matrix elasticity. PMID:24268417
Two-color ionization injection using a plasma beatwave accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schroeder, C. B.; Benedetti, C.; Esarey, E.
Two-color laser ionization injection is a method to generate ultra-low emittance (sub-100 nm transverse normalized emittance) beams in a laser-driven plasma accelerator. A plasma beatwave accelerator is proposed to drive the plasma wave for ionization injection, where the beating of the lasers effectively produces a train of long-wavelength pulses. The plasma beatwave accelerator excites a large amplitude plasma wave with low peak laser electric fields, leaving atomically-bound electrons with low ionization potential. A short-wavelength, low-amplitude ionization injection laser pulse (with a small ponderomotive force and large peak electric field) is used to ionize the remaining bound electrons at a wakemore » phase suitable for trapping, generating an ultra-low emittance electron beam that is accelerated in the plasma wave. Using a plasma beatwave accelerator for wakefield excitation, compared to short-pulse wakefield excitation, allows for a lower amplitude injection laser pulse and, hence, a lower emittance beam may be generated.« less
Searches for Continuous Gravitational Waves from Nine Young Supernova Remnants
NASA Astrophysics Data System (ADS)
Aasi, J.; Abbott, B. P.; Abbott, R.; Abbott, T.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Ain, A.; Ajith, P.; Alemic, A.; Allen, B.; Allocca, A.; Amariutei, D.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C.; Areeda, J. S.; Ast, S.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Aylott, B. E.; Babak, S.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barbet, M.; Barclay, S.; Barish, B. C.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Bartlett, J.; Barton, M. A.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Bauer, Th. S.; Baune, C.; Bavigadda, V.; Behnke, B.; Bejger, M.; Belczynski, C.; Bell, A. S.; Bell, C.; Benacquista, M.; Bergman, J.; Bergmann, G.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Biscans, S.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blackburn, L.; Blair, C. D.; Blair, D.; Bloemen, S.; Bock, O.; Bodiya, T. P.; Boer, M.; Bogaert, G.; Bojtos, P.; Bond, C.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Boschi, V.; Bose, Sukanta; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Briant, T.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brown, N. M.; Buchman, S.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Cadonati, L.; Cagnoli, G.; Calderón Bustillo, J.; Calloni, E.; Camp, J. B.; Cannon, K. C.; Cao, J.; Capano, C. D.; Carbognani, F.; Caride, S.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C.; Cesarini, E.; Chakraborty, R.; Chalermsongsak, T.; Chamberlin, S. J.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Chen, Y.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, S.; Chung, S.; Ciani, G.; Clara, F.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Collette, C.; Colombini, M.; Cominsky, L.; Constancio, M., Jr.; Conte, A.; Cook, D.; Corbitt, T. R.; Cornish, N.; Corsi, A.; Costa, C. A.; Coughlin, M. W.; Coulon, J.-P.; Countryman, S.; Couvares, P.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Craig, K.; Creighton, J. D. E.; Creighton, T. D.; Cripe, J.; Crowder, S. G.; Cumming, A.; Cunningham, L.; Cuoco, E.; Cutler, C.; Dahl, K.; Dal Canton, T.; Damjanic, M.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dartez, L.; Dattilo, V.; Dave, I.; Daveloza, H.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; DeBra, D.; Debreczeni, G.; Degallaix, J.; De Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dereli, H.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; DeSalvo, R.; Dhurandhar, S.; Díaz, M.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Di Virgilio, A.; Dojcinoski, G.; Dolique, V.; Dominguez, E.; Donovan, F.; Dooley, K. L.; Doravari, S.; Douglas, R.; Downes, T. P.; Drago, M.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dwyer, S.; Eberle, T.; Edo, T.; Edwards, M.; Edwards, M.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Essick, R.; Etzel, T.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Fan, X.; Fang, Q.; Farinon, S.; Farr, B.; Farr, W. M.; Favata, M.; Fays, M.; Fehrmann, H.; Fejer, M. M.; Feldbaum, D.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Fiori, I.; Fisher, R. P.; Flaminio, R.; Fournier, J.-D.; Franco, S.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Fritschel, P.; Frolov, V. V.; Fuentes-Tapia, S.; Fulda, P.; Fyffe, M.; Gair, J. R.; Gammaitoni, L.; Gaonkar, S.; Garufi, F.; Gatto, A.; Gehrels, N.; Gemme, G.; Gendre, B.; Genin, E.; Gennai, A.; Gergely, L. Á.; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gleason, J.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gordon, N.; Gorodetsky, M. L.; Gossan, S.; Gossler, S.; Gouaty, R.; Gräf, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Groot, P.; Grote, H.; Grunewald, S.; Guidi, G. M.; Guido, C. J.; Guo, X.; Gushwa, K.; Gustafson, E. K.; Gustafson, R.; Hacker, J.; Hall, E. D.; Hammond, G.; Hanke, M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M.; Hartman, M. T.; Haster, C.-J.; Haughian, K.; Heidmann, A.; Heintze, M.; Heinzel, G.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Heptonstall, A. W.; Heurs, M.; Hewitson, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Hofman, D.; Hollitt, S. E.; Holt, K.; Hopkins, P.; Hosken, D. J.; Hough, J.; Houston, E.; Howell, E. J.; Hu, Y. M.; Huerta, E.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh, M.; Huynh-Dinh, T.; Idrisy, A.; Indik, N.; Ingram, D. R.; Inta, R.; Islas, G.; Isler, J. C.; Isogai, T.; Iyer, B. R.; Izumi, K.; Jacobson, M.; Jang, H.; Jaranowski, P.; Jawahar, S.; Ji, Y.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; K, Haris; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kasprzack, M.; Katsavounidis, E.; Katzman, W.; Kaufer, H.; Kaufer, S.; Kaur, T.; Kawabe, K.; Kawazoe, F.; Kéfélian, F.; Keiser, G. M.; Keitel, D.; Kelley, D. B.; Kells, W.; Keppel, D. G.; Key, J. S.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, C.; Kim, K.; Kim, N. G.; Kim, N.; Kim, Y.-M.; King, E. J.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kline, J.; Koehlenbeck, S.; Kokeyama, K.; Kondrashov, V.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Kringel, V.; Krishnan, B.; Królak, A.; Krueger, C.; Kuehn, G.; Kumar, A.; Kumar, P.; Kuo, L.; Kutynia, A.; Landry, M.; Lantz, B.; Larson, S.; Lasky, P. D.; Lazzarini, A.; Lazzaro, C.; Lazzaro, C.; Le, J.; Leaci, P.; Leavey, S.; Lebigot, E.; Lebigot, E. O.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Leonardi, M.; Leong, J. R.; Leroy, N.; Letendre, N.; Levin, Y.; Levine, B.; Lewis, J.; Li, T. G. F.; Libbrecht, K.; Libson, A.; Lin, A. C.; Littenberg, T. B.; Lockerbie, N. A.; Lockett, V.; Logue, J.; Lombardi, A. L.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J.; Lubinski, M. J.; Lück, H.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macarthur, J.; MacDonald, T.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magaña na-Sandoval, F.; Magee, R.; Mageswaran, M.; Maglione, C.; Mailand, K.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandel, I.; Mandic, V.; Mangano, V.; Mangano, V.; Mansell, G. L.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A.; Maros, E.; Martelli, F.; Martellini, L.; Martin, I. W.; Martin, R. M.; Martynov, D.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McGuire, S. C.; McIntyre, G.; McIver, J.; McLin, K.; McWilliams, S.; Meacher, D.; Meadors, G. D.; Meidam, J.; Meinders, M.; Melatos, A.; Mendell, G.; Mercer, R. A.; Meshkov, S.; Messenger, C.; Meyers, P. M.; Mezzani, F.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A.; Miller, J.; Millhouse, M.; Minenkov, Y.; Ming, J.; Mirshekari, S.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Moggi, A.; Mohan, M.; Mohanty, S. D.; Mohapatra, S. R. P.; Moore, B.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, C. L.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Munch, J.; Murphy, D.; Murray, P. G.; Mytidis, A.; Nagy, M. F.; Nardecchia, I.; Nash, T.; Naticchioni, L.; Nayak, R. K.; Necula, V.; Nedkova, K.; Nelemans, G.; Neri, I.; Neri, M.; Newton, G.; Nguyen, T.; Nielsen, A. B.; Nissanke, S.; Nitz, A. H.; Nocera, F.; Nolting, D.; Normandin, M. E. N.; Nuttall, L. K.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oppermann, P.; Oram, R.; O'Reilly, B.; Ortega, W.; O'Shaughnessy, R.; Osthelder, C.; Ott, C. D.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Padilla, C.; Pai, A.; Pai, S.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Papa, M. A.; Paris, H.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patrick, Z.; Pedraza, M.; Pekowsky, L.; Pele, A.; Penn, S.; Perreca, A.; Phelps, M.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Poeld, J.; Poggiani, R.; Post, A.; Poteomkin, A.; Powell, J.; Prasad, J.; Predoi, V.; Premachandra, S.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prix, R.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qin, J.; Quetschke, V.; Quintero, E.; Quiroga, G.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Raja, S.; Rajalakshmi, G.; Rakhmanov, M.; Ramirez, K.; Rapagnani, P.; Raymond, V.; Razzano, M.; Re, V.; Reed, C. M.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Reula, O.; Ricci, F.; Riles, K.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V.; Romano, R.; Romanov, G.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Saleem, M.; Salemi, F.; Sammut, L.; Sandberg, V.; Sanders, J. R.; Sannibale, V.; Santiago-Prieto, I.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Savage, R.; Sawadsky, A.; Scheuer, J.; Schilling, R.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schreiber, E.; Schuette, D.; Schutz, B. F.; Scott, J.; Scott, S. M.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Serna, G.; Sevigny, A.; Shaddock, D. A.; Shah, S.; Shahriar, M. S.; Shaltev, M.; Shao, Z.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sidery, T. L.; Siellez, K.; Siemens, X.; Sigg, D.; Silva, A. D.; Simakov, D.; Singer, A.; Singer, L.; Singh, R.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, J. R.; Smith, M. R.; Smith, R. J. E.; Smith-Lefebvre, N. D.; Son, E. J.; Sorazu, B.; Souradeep, T.; Staley, A.; Stebbins, J.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stephens, B. C.; Steplewski, S.; Stevenson, S.; Stone, R.; Strain, K. A.; Straniero, N.; Strigin, S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sutton, P. J.; Swinkels, B.; Szczepanczyk, M.; Szeifert, G.; Tacca, M.; Talukder, D.; Tanner, D. B.; Tápai, M.; Tarabrin, S. P.; Taracchini, A.; Taylor, R.; Tellez, G.; Theeg, T.; Thirugnanasambandam, M. P.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Tiwari, V.; Tomlinson, C.; Tonelli, M.; Torres, C. V.; Torrie, C. I.; Travasso, F.; Traylor, G.; Tse, M.; Tshilumba, D.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Vajente, G.; Valdes, G.; Vallisneri, M.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; van den Broeck, C.; van der Sluys, M. V.; van Heijningen, J.; van Veggel, A. A.; Vass, S.; Vasúth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Vetrano, F.; Viceré, A.; Vincent-Finley, R.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Vousden, W. D.; Vyatchanin, S. P.; Wade, A. R.; Wade, L.; Wade, M.; Walker, M.; Wallace, L.; Walsh, S.; Wang, H.; Wang, M.; Wang, X.; Ward, R. L.; Warner, J.; Was, M.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.; Wessels, P.; Westphal, T.; Wette, K.; Whelan, J. T.; White, D. J.; Whiting, B. F.; Wilkinson, C.; Williams, L.; Williams, R.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Worden, J.; Xie, S.; Yablon, J.; Yakushin, I.; Yam, W.; Yamamoto, H.; Yancey, C. C.; Yang, Q.; Yvert, M.; Zadrożny, A.; Zanolin, M.; Zendri, J.-P.; Zhang, Fan; Zhang, L.; Zhang, M.; Zhang, Y.; Zhao, C.; Zhou, M.; Zhu, X. J.; Zucker, M. E.; Zuraw, S.; Zweizig, J.
2015-11-01
We describe directed searches for continuous gravitational waves (GWs) in data from the sixth Laser Interferometer Gravitational-wave Observatory (LIGO) science data run. The targets were nine young supernova remnants not associated with pulsars; eight of the remnants are associated with non-pulsing suspected neutron stars. One target's parameters are uncertain enough to warrant two searches, for a total of 10. Each search covered a broad band of frequencies and first and second frequency derivatives for a fixed sky direction. The searches coherently integrated data from the two LIGO interferometers over time spans from 5.3-25.3 days using the matched-filtering {F}-statistic. We found no evidence of GW signals. We set 95% confidence upper limits as strong (low) as 4 × 10-25 on intrinsic strain, 2 × 10-7 on fiducial ellipticity, and 4 × 10-5 on r-mode amplitude. These beat the indirect limits from energy conservation and are within the range of theoretical predictions for neutron-star ellipticities and r-mode amplitudes.
Two-color ionization injection using a plasma beatwave accelerator
Schroeder, C. B.; Benedetti, C.; Esarey, E.; ...
2018-01-10
Two-color laser ionization injection is a method to generate ultra-low emittance (sub-100 nm transverse normalized emittance) beams in a laser-driven plasma accelerator. A plasma beatwave accelerator is proposed to drive the plasma wave for ionization injection, where the beating of the lasers effectively produces a train of long-wavelength pulses. The plasma beatwave accelerator excites a large amplitude plasma wave with low peak laser electric fields, leaving atomically-bound electrons with low ionization potential. A short-wavelength, low-amplitude ionization injection laser pulse (with a small ponderomotive force and large peak electric field) is used to ionize the remaining bound electrons at a wakemore » phase suitable for trapping, generating an ultra-low emittance electron beam that is accelerated in the plasma wave. Using a plasma beatwave accelerator for wakefield excitation, compared to short-pulse wakefield excitation, allows for a lower amplitude injection laser pulse and, hence, a lower emittance beam may be generated.« less
A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer.
Zuanetti, Bryan; Wang, Tianxue; Prakash, Vikas
2017-03-01
While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this paper, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ∼2.9 km/s. Sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.
Ogunlade, Oluwadare; Ayoka, Abiodun O; Akomolafe, Rufus O; Akinsomisoye, Olumide S; Irinoye, Adedayo I; Ajao, Adewale; Asafa, Muritala A
2015-09-28
Dextrocardia with situs inversus is a rare congenital disease. In patients with this condition, the heart is presented as a mirror image of itself with its apex pointing to the right. The pulmonary and abdominal anatomies are reversed. Dextrocardia with situs inversus occurs at birth but its diagnosis may be in adulthood. This case advances knowledge by graphically describing the unusual electrocardiographic features of dextrocardia in a young adult. We report a case of a 22-year-old Nigerian man of Yoruba ethnicity who presented himself for preadmission medical test. He had a standard 12-lead electrocardiogram which revealed uncommon features: inversion of P waves in leads I, aVL and aVR; dominantly negative QRS waves in leads I, V1 to V6; reverse R wave progression in chest leads; low voltage in V4 to V6; extreme QRS axis; flattened T waves in V4 to V6 and aVR; and inverted T waves in lead I and aVL. An electrocardiogram diagnosis of dextrocardia was made. The differential diagnosis considered was right ventricular hypertrophy. A cardiovascular examination showed pulse rate of 70 beats per minute, blood pressure of 119/62mmHg, visible cardiac impulse at right precordium, apex beat was located at his fifth right intercostal space mid-clavicular line. A chest X-ray (posterior anterior view) including upper abdomen showed dextrocardia; his aortic arch was located on the right. His stomach bubble was located below his right hemidiaphragm. His trachea was slightly deviated to the left. The findings in his lung fields were not remarkable. Abdominopelvic ultrasonography showed that right-sided intra-abdominal organs (liver, gallbladder) were located on the left while left-sided organs (stomach, spleen) were located on the right. His abdominal aorta was on the right while his inferior vena cava was located on the left. A diagnosis of dextrocardia with situs inversus was made ultrasonographically. A properly interpreted electrocardiogram was useful in suspecting the diagnosis of dextrocardia with situs inversus. So, an analysis of a relatively simple and non-invasive diagnostic tool such as an electrocardiogram allows for suspicion of a cardiovascular anomaly in a setting of scarce diagnostic resources.
Systolic time interval data acquisition system. Specialized cardiovascular studies
NASA Technical Reports Server (NTRS)
Baker, J. T.
1976-01-01
The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.
Digital processing of RF signals from optical frequency combs
NASA Astrophysics Data System (ADS)
Cizek, Martin; Smid, Radek; Buchta, Zdeněk.; Mikel, Břetislav; Lazar, Josef; Cip, Ondřej
2013-01-01
The presented work is focused on digital processing of beat note signals from a femtosecond optical frequency comb. The levels of mixing products of single spectral components of the comb with CW laser sources are usually very low compared to products of mixing all the comb components together. RF counters are more likely to measure the frequency of the strongest spectral component rather than a weak beat note. Proposed experimental digital signal processing system solves this problem by analyzing the whole spectrum of the output RF signal and using software defined radio (SDR) algorithms. Our efforts concentrate in two main areas: Firstly, using digital servo-loop techniques for locking free running continuous laser sources on single components of the fs comb spectrum. Secondly, we are experimenting with digital signal processing of the RF beat note spectrum produced by f-2f 1 technique used for assessing the offset and repetition frequencies of the comb, resulting in digital servo-loop stabilization of the fs comb. Software capable of computing and analyzing the beat-note RF spectrums using FFT and peak detection was developed. A SDR algorithm performing phase demodulation on the f- 2f signal is used as a regulation error signal source for a digital phase-locked loop stabilizing the offset frequency of the fs comb.
Digital processing of signals from femtosecond combs
NASA Astrophysics Data System (ADS)
Čížek, Martin; Šmíd, Radek; Buchta, Zdeněk.; Mikel, Břetislav; Lazar, Josef; Číp, Ondrej
2012-01-01
The presented work is focused on digital processing of beat note signals from a femtosecond optical frequency comb. The levels of mixing products of single spectral components of the comb with CW laser sources are usually very low compared to products of mixing all the comb components together. RF counters are more likely to measure the frequency of the strongest spectral component rather than a weak beat note. Proposed experimental digital signal processing system solves this problem by analyzing the whole spectrum of the output RF signal and using software defined radio (SDR) algorithms. Our efforts concentrate in two main areas: Firstly, we are experimenting with digital signal processing of the RF beat note spectrum produced by f-2f 1 technique and with fully digital servo-loop stabilization of the fs comb. Secondly, we are using digital servo-loop techniques for locking free running continuous laser sources on single components of the fs comb spectrum. Software capable of computing and analyzing the beat-note RF spectrums using FFT and peak detection was developed. A SDR algorithm performing phase demodulation on the f- 2f signal is used as a regulation error signal source for a digital phase-locked loop stabilizing the offset and repetition frequencies of the fs comb.
Closed-loop control of zebrafish response using a bioinspired robotic-fish in a preference test
Kopman, Vladislav; Laut, Jeffrey; Polverino, Giovanni; Porfiri, Maurizio
2013-01-01
In this paper, we study the response of zebrafish to a robotic-fish whose morphology and colour pattern are inspired by zebrafish. Experiments are conducted in a three-chambered instrumented water tank where a robotic-fish is juxtaposed with an empty compartment, and the preference of live subjects is scored as the mean time spent in the vicinity of the tank's two lateral sides. The tail-beating of the robotic-fish is controlled in real-time based on feedback from fish motion to explore a spectrum of closed-loop systems, including proportional and integral controllers. Closed-loop control systems are complemented by open-loop strategies, wherein the tail-beat of the robotic-fish is independent of the fish motion. The preference space and the locomotory patterns of fish for each experimental condition are analysed and compared to understand the influence of real-time closed-loop control on zebrafish response. The results of this study show that zebrafish respond differently to the pattern of tail-beating motion executed by the robotic-fish. Specifically, the preference and behaviour of zebrafish depend on whether the robotic-fish tail-beating frequency is controlled as a function of fish motion and how such closed-loop control is implemented. PMID:23152102
Ali, Wail; Bubolz, Beth A; Nguyen, Linh; Castro, Danny; Coss-Bu, Jorge; Quach, Michael M; Kennedy, Curtis E; Anderson, Anne E; Lai, Yi-Chen
2017-12-01
Convulsive status epilepticus can exert profound cardiovascular effects in adults including ventricular depolarization-repolarization abnormalities. Whether status epilepticus adversely affects ventricular electrical properties in children is less understood. Therefore, we sought to characterize ventricular alterations and the associated clinical factors in children following convulsive status epilepticus. We conducted a 2-year retrospective, case-control study. Children between 1 month and 21 years of age were included if they were admitted to the pediatric intensive care unit with primary diagnosis of convulsive status epilepticus and had 12-lead electrocardiogram (ECG) within 24 hours of admission. Children with heart disease, ion channelopathy, or on vasoactive medications were excluded. Age-matched control subjects had no history of seizures or epilepsy. The primary outcome was ventricular abnormalities represented by ST segment changes, abnormal T wave, QRS axis deviation, and corrected QT (QTc) interval prolongation. The secondary outcomes included QT/RR relationship, beat-to-beat QTc interval variability, ECG interval measurement between groups, and clinical factors associated with ECG abnormalities. Of 317 eligible children, 59 met the inclusion criteria. History of epilepsy was present in 31 children (epileptic) and absent in 28 children (non-epileptic). Compared with the control subjects (n = 31), the status epilepticus groups were more likely to have an abnormal ECG with overall odds ratio of 3.8 and 7.0 for the non-epileptic and the epileptic groups respectively. Simple linear regression analysis demonstrated that children with epilepsy exhibited impaired dependence and adaptation of the QT interval on heart rate. Beat-to-beat QTc interval variability, a marker of ventricular repolarization instability, was increased in children with epilepsy. Convulsive status epilepticus can adversely affect ventricular electrical properties and stability in children, especially those with epilepsy. These findings suggest that children with epilepsy may be particularly vulnerable to seizure-induced arrhythmias. Therefore postictal cardiac surveillance may be warranted in this population.
Influences of lifestyle factors on cardiac autonomic nervous system activity over time.
Hu, Mandy Xian; Lamers, Femke; de Geus, Eco J C; Penninx, Brenda W J H
2017-01-01
Physical activity, alcohol use and smoking might affect cardiovascular disease through modifying autonomic nervous system (ANS) activity. We investigated: 1) whether there are consistent relationships between lifestyle factors and cardiac ANS activity over time, and 2) whether 2-year changes in lifestyle factors relate to 2-year changes in cardiac activity. Baseline (n=2618) and 2-year follow-up (n=2010) data of the Netherlands Study of Depression and Anxiety was combined. Baseline data was collected in the Netherlands from 2004-2007. Lifestyle factors were habitual physical activity, frequency of sport activities, alcohol use, and smoking. Indicators of cardiac activity were heart rate (HR), respiratory sinus arrhythmia (RSA) and pre-ejection period (PEP) (100min of registration). The results showed that high physical activity (-1.8beats/min compared to low activity), high frequency of sport activities ('couple of times/week': -2.5beats/min compared to 'almost never') and mild/moderate alcohol use (-1.2beats/min compared to non-drinking) were related to low HR. Heavy smoking was related to high HR (>30cigarettes/day: +5.1beats/min compared to non-smoking). High frequency of sport activities was associated with high RSA ('couple of times/week':+1.7ms compared to 'almost never') and moderate smoking with longer PEP (11-20cigarettes/day: +2.8ms compared to non-smoking). Associations were consistent across waves. Furthermore, 2-year change in frequency of sport activities and number of smoked cigarettes/day was accompanied by 2-year change in HR (β=-0.076 and β=0.101, respectively) and RSA (β=0.046 and β=-0.040, respectively). Our findings support consistent effects of lifestyle on HR and parasympathetic activity in the expected direction. Cardiac autonomic dysregulation may be partly mediating the relationship between lifestyle and subsequent cardiovascular health. Copyright © 2016 Elsevier Inc. All rights reserved.
Binaural Beat: A Failure to Enhance EEG Power and Emotional Arousal
López-Caballero, Fran; Escera, Carles
2017-01-01
When two pure tones of slightly different frequencies are delivered simultaneously to the two ears, is generated a beat whose frequency corresponds to the frequency difference between them. That beat is known as acoustic beat. If these two tones are presented one to each ear, they still produce the sensation of the same beat, although no physical combination of the tones occurs outside the auditory system. This phenomenon is called binaural beat. In the present study, we explored the potential contribution of binaural beats to the enhancement of specific electroencephalographic (EEG) bands, as previous studies suggest the potential usefulness of binaural beats as a brainwave entrainment tool. Additionally, we analyzed the effects of binaural-beat stimulation on two psychophysiological measures related to emotional arousal: heart rate and skin conductance. Beats of five different frequencies (4.53 Hz -theta-, 8.97 Hz -alpha-, 17.93 Hz -beta-, 34.49 Hz -gamma- or 57.3 Hz -upper-gamma) were presented binaurally and acoustically for epochs of 3 min (Beat epochs), preceded and followed by pink noise epochs of 90 s (Baseline and Post epochs, respectively). In each of these epochs, we analyzed the EEG spectral power, as well as calculated the heart rate and skin conductance response (SCR). For all the beat frequencies used for stimulation, no significant changes between Baseline and Beat epochs were observed within the corresponding EEG bands, neither with binaural or with acoustic beats. Additional analysis of spectral EEG topographies yielded negative results for the effect of binaural beats in the scalp distribution of EEG spectral power. In the psychophysiological measures, no changes in heart rate and skin conductance were observed for any of the beat frequencies presented. Our results do not support binaural-beat stimulation as a potential tool for the enhancement of EEG oscillatory activity, nor to induce changes in emotional arousal. PMID:29187819
Binaural Beat: A Failure to Enhance EEG Power and Emotional Arousal.
López-Caballero, Fran; Escera, Carles
2017-01-01
When two pure tones of slightly different frequencies are delivered simultaneously to the two ears, is generated a beat whose frequency corresponds to the frequency difference between them. That beat is known as acoustic beat. If these two tones are presented one to each ear, they still produce the sensation of the same beat, although no physical combination of the tones occurs outside the auditory system. This phenomenon is called binaural beat. In the present study, we explored the potential contribution of binaural beats to the enhancement of specific electroencephalographic (EEG) bands, as previous studies suggest the potential usefulness of binaural beats as a brainwave entrainment tool. Additionally, we analyzed the effects of binaural-beat stimulation on two psychophysiological measures related to emotional arousal: heart rate and skin conductance. Beats of five different frequencies (4.53 Hz -theta-, 8.97 Hz -alpha-, 17.93 Hz -beta-, 34.49 Hz -gamma- or 57.3 Hz -upper-gamma) were presented binaurally and acoustically for epochs of 3 min (Beat epochs), preceded and followed by pink noise epochs of 90 s (Baseline and Post epochs, respectively). In each of these epochs, we analyzed the EEG spectral power, as well as calculated the heart rate and skin conductance response (SCR). For all the beat frequencies used for stimulation, no significant changes between Baseline and Beat epochs were observed within the corresponding EEG bands, neither with binaural or with acoustic beats. Additional analysis of spectral EEG topographies yielded negative results for the effect of binaural beats in the scalp distribution of EEG spectral power. In the psychophysiological measures, no changes in heart rate and skin conductance were observed for any of the beat frequencies presented. Our results do not support binaural-beat stimulation as a potential tool for the enhancement of EEG oscillatory activity, nor to induce changes in emotional arousal.
Namdar, Hossein; Taban Sadeghi, Mohammadreza; Sabourimoghaddam, Hassan; Sadeghi, Babak; Ezzati, Davoud
2014-01-01
The present research investigated the effects of two different types of music on cardiovascular responses in essential hypertensive men in comparison with healthy men based on introversion and extraversion. One hundred and thirteen hypertensive men referred to Madani Heart Hospital in Tabriz completed the NEO-FFI Questionnaire and after obtaining acceptable scores were classified in four groups: introvert patients, extravert patients, introvert healthy subjects, and extravert healthy subjects (each group with 25 samples with age range 31-50). Baseline blood pressure and heart rate of each subject was recorded without any stimulus. Then subjects were exposed to slow-beat music and blood pressure and heart rate were recorded. After15 minute break, and a little cognitive task for distraction, subjects were exposed to fast-beat music and blood pressure and heart rate were recorded again. Multivariate analysis of covariance (MANCOVA) test showed that extravert patient subjects obtained greater reduction in systolic blood pressure and heart rate after presenting slow-beat music compared with introvert patients (P= 0.035, and P= 0.033 respectively). And extravert healthy subjects obtained greater reduction in heart rate after presenting slow-beat music compared with introvert healthy subjects (P= 0.036). However, there are no significant differences between introvert and extravert groups in systolic and diastolic blood pressure and heart rate after presenting fast-beat music. Based on our results, introvert subjects experience negative emotions more than extravert subjects and negative emotions cause less change in blood pressure in these subjects compared with extravert subjects.
Namdar, Hossein; Taban Sadeghi, Mohammadreza; Sabourimoghaddam, Hassan; Sadeghi, Babak; Ezzati, Davoud
2014-01-01
Introduction: The present research investigated the effects of two different types of music on cardiovascular responses in essential hypertensive men in comparison with healthy men based on introversion and extraversion. Methods: One hundred and thirteen hypertensive men referred to Madani Heart Hospital in Tabriz completed the NEO-FFI Questionnaire and after obtaining acceptable scores were classified in four groups: introvert patients, extravert patients, introvert healthy subjects, and extravert healthy subjects (each group with 25 samples with age range 31-50). Baseline blood pressure and heart rate of each subject was recorded without any stimulus. Then subjects were exposed to slow-beat music and blood pressure and heart rate were recorded. After15 minute break, and a little cognitive task for distraction, subjects were exposed to fast-beat music and blood pressure and heart rate were recorded again. Results: Multivariate analysis of covariance (MANCOVA) test showed that extravert patient subjects obtained greater reduction in systolic blood pressure and heart rate after presenting slow-beat music compared with introvert patients (P= 0.035, and P= 0.033 respectively). And extravert healthy subjects obtained greater reduction in heart rate after presenting slow-beat music compared with introvert healthy subjects (P= 0.036). However, there are no significant differences between introvert and extravert groups in systolic and diastolic blood pressure and heart rate after presenting fast-beat music. Conclusion: Based on our results, introvert subjects experience negative emotions more than extravert subjects and negative emotions cause less change in blood pressure in these subjects compared with extravert subjects. PMID:25320667
Kay, Matthew; Swift, Luther; Martell, Brian; Arutunyan, Ara; Sarvazyan, Narine
2008-05-01
We studied the origins of ectopic beats during low-flow reperfusion after acute regional ischemia in excised rat hearts. The left anterior descending coronary artery was cannulated. Perfusate was delivered to the cannula using an high-performance liquid chromatography pump. This provided not only precise control of flow rate but also avoided mechanical artifacts associated with vessel occlusion and deocclusion. Optical mapping of epicardial transmembrane potential served to identify activation wavefronts. Imaging of NADH fluorescence was used to quantify local ischemia. Our experiments suggest that low-flow reperfusion of ischemic myocardium leads to a highly heterogeneous ischemic substrate and that the degree of ischemia between adjacent patches of tissue changes in time. In contrast to transient ectopic activity observed during full-flow reperfusion, persistent ectopic arrhythmias were observed during low-flow reperfusion. The origins of ectopic beats were traceable to areas of high spatial gradients of changes in NADH fluorescence caused by low-flow reperfusion.
Arisi, G; Macchi, E; Baruffi, S; Musso, E; Spaggiari, S; Stilli, D; Taccardi, B
1982-01-01
Previous work on the spread of excitation on the dog's ventricular surface enabled us to locate up to 30 breakthrough points (BKTPs) where excitation reaches the ventricular surface. In particular the equipotential contour maps enabled us to detect 3 to 5 BKTPs on the anterior right ventricular surface, near the a-v groove when a large part of ventricular surface was still at rest. With a view to investigating the mechanism underlying the early excitation of these basal regions, we stimulated the heart at several right ventricular BKTPs and in other points located at a distance from the BKTPs. The instantaneous equipotential maps showed that after stimulation most right ventricular BKTPs remained in the same position as observed the normal beats. The early appearance of epicardial wavefronts in the basal region and generally in other areas of the right ventricle was attributed to the rapid propagation of excitation waves through the Purkinje network, probably associated to a short transmural crossing time, due to a local thinness of the ventricular wall.
Smith-Purcell terahertz radiation from laser modulated electron beam over a metallic grating
NASA Astrophysics Data System (ADS)
Kumar, Pawan; Bhasin, Lalita; Tripathi, V. K.; Kumar, Ashok; Kumar, Manoj
2016-09-01
We propose a novel scheme of terahertz (THz) radiation generation from the beat frequency modulation of an electron beam by two co-propagating lasers and the generation of terahertz radiation by the modulated beam passing over a periodic metallic grating. The lasers cause velocity modulation of the beam by exerting a longitudinal ponderomotive force on it. In the drift space between the modulator and metallic grating, the velocity modulation translates into density and current modulation. The modulated beam, propagating over the grating of specific wave number, induces space periodic image current in the conductor that emits beat frequency Smith-Purcell radiation. With 1 μm, 4 × 1016 W/cm2 lasers, beam current modulation of the order of 50% can be achieved at optimum lengths of the modulator and drift space. Employing 10 mA, 0.5 MeV short-period electron beam, propagating at a height of 50 μ m above the grating of period 150 μm, one may obtain THz radiated power of the order of 6 mW at 10 THz.
Cardiac safety strategies. 25-26 October 2005, the Radisson SAS Hotel, Nice, France.
Hanton, Gilles; Tilbury, Lorraine
2006-03-01
This meeting was organised by IIR Life Sciences. It was chaired by Brian Guth, (head of General Pharmacology at Boehringer Ingelheim Pharma) and brought together scientists and clinicians from the pharmaceutical industry, university and regulatory agencies. The meeting presented emerging trends in cardiac safety, including its regulatory context pertaining to ICH S7A, S7B and E14. ICH S7A and S7B highlight the importance of the hERG test and telemetric studies in non-rodents. ICH E14 describes the clinical 'thorough QT study' that is required by the FDA for any new drug. Marked physiological variability in QT interval over time can be observed, partly as a result of fluctuation in autonomic tone. Beat-to-beat QT variability and T-wave morphology should be considered as a part of an integrated estimate of proarrhythmic risk. A case study illustrated the predictivity of preclinical data for proarrhythmic risk in humans, showing the importance of evaluating QT effects in patients to establish a safety margin.
Bistable synchronization modes in hydrodynamically coupled micro-rotors
NASA Astrophysics Data System (ADS)
Guo, Hanliang; Kanale, Anup; Fuerthauer, Sebastian; Kanso, Eva
2017-11-01
Cilia often beat in synchrony, and they may transition between different synchronization modes in the same cell type. For example, cilia in the mammalian brain ventricles are reported to periodically change their collective beat orientation, providing a cilia-based switch for redirecting the transport of cerebrospinal fluid. Experimental and theoretical evidences suggest that phase coordinations can be achieved solely via hydrodynamical interactions. However, the exact mechanisms responsible for transitioning between various synchronization modes remain illusive. Here, we use a theoretical model where each cilium is represented by a bead moving along a closed trajectory close to a no-slip surface. We investigate the emergent synchronization modes and their stability for various cilia-inspired force profiles. We observe distinct stable synchronization modes between two rotors, including a bistable regime where both in-phase and anti-phase synchronizations are stable. We then extend this analysis to an array of rotors where we demonstrate the dynamical formations of metachronal waves. These findings may help us to understand the origin of synchrony in biological and bio-inspired systems, and the mechanisms underlying transitions between different synchronization modes.
Optically stimulated slowing of polar heavy-atom molecules with a constant beat phase
NASA Astrophysics Data System (ADS)
Yin, Yanning; Xu, Supeng; Xia, Meng; Xia, Yong; Yin, Jianping
2018-04-01
Polar heavy-atom molecules have been well recognized as promising candidates for precision measurements and tests of fundamental physics. A much slower molecular beam to increase the interaction time should lead to a more sensitive measurement. Here we theoretically demonstrate the possibility of the stimulated longitudinal slowing of heavy-atom molecules by the coherent optical bichromatic force with a constant beat phase. Taking the YbF meolecule as an example, we show that a rapid and short-distance deceleration of heavy molecules by a phase-compensation method is feasible with moderate conditions. A molecular beam of YbF with a forward velocity of 120 m/s can be decelerated below 10 m/s within a distance of 3.5 cm and with a laser irradiance for each traveling wave of 107.2 W/cm 2 . Our proposed slowing method could be a promising approach to break through the space constraint or the limited capture efficiency of molecules loadable into a magneto-optical trap in traditional deceleration schemes, opening the possibility for a significant improvement of the precision measurement sensitivity.
Time-lapse imaging of human heart motion with switched array UWB radar.
Brovoll, Sverre; Berger, Tor; Paichard, Yoann; Aardal, Øyvind; Lande, Tor Sverre; Hamran, Svein-Erik
2014-10-01
Radar systems for detection of human heartbeats have mostly been single-channel systems with limited spatial resolution. In this paper, a radar system for ultra-wideband (UWB) imaging of the human heart is presented. To make the radar waves penetrate the human tissue the antenna is placed very close to the body. The antenna is an array with eight elements, and an antenna switch system connects the radar to the individual elements in sequence to form an image. Successive images are used to build up time-lapse movies of the beating heart. Measurements on a human test subject are presented and the heart motion is estimated at different locations inside the body. The movies show rhythmic motion consistent with the beating heart, and the location and shape of the reflections correspond well with the expected response form the heart wall. The spatial dependent heart motion is compared to ECG recordings, and it is confirmed that heartbeat modulations are seen in the radar data. This work shows that radar imaging of the human heart may provide valuable information on the mechanical movement of the heart.
NASA Astrophysics Data System (ADS)
Yang, Qiang; Xu, Xiao; Lai, Puxiang; Sang, Xinzhu; Wang, Lihong V.
2014-03-01
Focusing light inside highly scattering media beyond the ballistic regime is a challenging task in biomedical optical imaging, manipulation, and therapy. This challenge can be overcome by time reversing ultrasonically encoded (TRUE) diffuse light to the ultrasonic focus inside a turbid medium. In TRUE optical focusing, a photorefractive crystal or polymer is used as the phase conjugate mirror for optical time reversal. Accordingly, a relatively long ultrasound burst, whose duration matches the response time of the photorefractive material, is used to encode the diffuse light. With this long ultrasound burst, the resolution of the TRUE focus along the acoustic axis is poor. In this work, we used two transducers, emitting two intersecting ultrasound beams at 3.4 MHz and 3.6 MHz respectively, to modulate the diffuse light within their intersection volume at the beat frequency. We show that light encoded at the beat frequency can be time-reversed and converge to the intersection volume. Experimentally, TRUE focusing with an acoustic axial resolution of ~1.1 mm was demonstrated inside turbid media, agreeing with the theoretical estimation.
1975-06-01
beat model for the filtered series is based upon estimates of residual variances. One proceedo by estimating the parameters of the different models for...8217.4.%7 subjects were screened for nor-mality of binaural hearin_ and for Ntter !ne-cal requirements az prescribed by the staf: at Patterson Ary Hospital...selecting the beat normal populavton,"Journal of the American Statistilcal Association, Vol. 67, No. 339. pp. 1061 Bechhofer, R. E. (1954); "A single-sampl
Farkas, Attila S; Makra, Péter; Csík, Norbert; Orosz, Szabolcs; Shattock, Michael J; Fülöp, Ferenc; Forster, Tamás; Csanády, Miklós; Papp, Julius Gy; Varró, András; Farkas, András
2009-01-01
Background and purpose: The Na+/Ca2+ exchanger (NCX) may contribute to triggered activity and transmural dispersion of repolarization, which are substrates of torsades de pointes (TdP) type arrhythmias. This study examined the effects of selective inhibition of the NCX by SEA0400 on the occurrence of dofetilide-induced TdP. Experimental approach: Effects of SEA0400 (1 µmol·L−1) on dofetilide-induced TdP was studied in isolated, Langendorff-perfused, atrioventricular (AV)-blocked rabbit hearts. To verify the relevance of the model, lidocaine (30 µmol·L−1) and verapamil (750 nmol·L−1) were also tested against dofetilide-induced TdP. Key results: Acute AV block caused a chaotic idioventricular rhythm and strikingly increased beat-to-beat variability of the RR and QT intervals. SEA0400 exaggerated the dofetilide-induced increase in the heart rate-corrected QT interval (QTc) and did not reduce the incidence of dofetilide-induced TdP [100% in the SEA0400 + dofetilide group vs. 75% in the dofetilide (100 nmol·L−1) control]. In the second set of experiments, verapamil further increased the dofetilide-induced QTc prolongation and neither verapamil nor lidocaine reduced the dofetilide-induced increase in the beat-to-beat variability of the QT interval. However, lidocaine decreased and verapamil prevented the development of dofetilide-induced TdP as compared with the dofetilide control (TdP incidence: 13%, 0% and 88% respectively). Conclusions and implications: Na+/Ca2+ exchanger does not contribute to dofetilide-induced TdP, whereas Na+ and Ca2+ channel activity is involved in TdP genesis in isolated, AV-blocked rabbit hearts. Neither QTc prolongation nor an increase in the beat-to-beat variability of the QT interval is a sufficient prerequisite of TdP genesis in rabbit hearts. PMID:19222480
Abisse, Saddam S.; Lampert, Rachel; Burg, Mattew; Soufer, Robert; Shusterman, Vladimir
2011-01-01
Introduction Changes in the autonomic nervous system activity (ANS) are a major trigger of life-threatening ventricular tachyarrhythmias (VTA). Mental arithmetic, a condition administered in a laboratory setting, can provide insight into the ANS effects on cardiac physiology. We examined the responses of cardiac repolarization to laboratory-induced psychological stressors in patients with implantable cardioverter defibrillators (ICDs) with the objective of identifying the indices that differentiate patients with and without subsequent VTA in follow-up. Methods Continuous ECG signals were recorded using 3 standard bipolar (Holter) leads in 56 patients (age: 63.6±11.9, female: 12%, LVEF: 32.3±11) with ICDs during mental arithmetic. The patients were separated into those with subsequent VTA during 3–4 years of follow-up (Group 1: N=9 pts) and those without VTA (Group 2: N=47 pts). Changes in repolarization (QT-interval, mean T-wave amplitude (Tamp), and T-wave area (Tarea) were analyzed during 5min of baseline, stress and recovery. The temporal instability of Tamp and Tarea was examined using the range (Δ) and variance (σ2) of beat-to-beat variations of the corresponding parameters. Results There were no significant differences in HR between the two groups at baseline (61 vs. 63 bpm, p=0.97), during stress (64 vs. 65 bpm, p=0.40), and recovery (62 vs. 61 bpm, p= 0.88). However, during mental stress and post-stress recovery ΔTamp was almost 2-fold greater in Group 1 compared with Group 2 (111 (57–203)) vs. 68 (44–94) μV p=0.04, respectively). Changes in QT-intervals were also greater in Group 1 compared with Group 2 (p=0.02). Conclusion Among patients with ICDs, changes of T-wave amplitude after psychological stress were greater in those with subsequent arrhythmic events. This might signal proarrhythmic repolarization response and help identify patients who would benefit the most from ICD implantation and proactive management. PMID:21920534
Terahertz Magnon-Polaritons in TmFeO3.
Grishunin, Kirill; Huisman, Thomas; Li, Guanqiao; Mishina, Elena; Rasing, Theo; Kimel, Alexey V; Zhang, Kailing; Jin, Zuanming; Cao, Shixun; Ren, Wei; Ma, Guo-Hong; Mikhaylovskiy, Rostislav V
2018-04-18
Magnon-polaritons are shown to play a dominant role in the propagation of terahertz (THz) waves through TmFeO 3 orthoferrite, if the frequencies of the waves are in the vicinity of the quasi-antiferromagnetic spin resonance mode. Both time-domain THz transmission and emission spectroscopies reveal clear beatings between two modes with frequencies slightly above and slightly below this resonance, respectively. Rigorous modeling of the interaction between the spins of TmFeO 3 and the THz light shows that the frequencies correspond to the upper and lower magnon-polariton branches. Our findings reveal the previously ignored importance of propagation effects and polaritons in such heavily debated areas as THz magnonics and THz spectroscopy of electromagnons. It also shows that future progress in these areas calls for an interdisciplinary approach at the interface between magnetism and photonics.
Energy dissipation rate as a determiner of Langmuir Wave turbulence in Stimulated Raman Scattering
NASA Astrophysics Data System (ADS)
Rose, Harvey A.
1998-11-01
In the steady state, the Manley Rowe relation relates the spatial growth of backscattered SRS to the local rate of Langmuir wave (LW) energy dissipation, ɛ. Past some threshold, the beating of the laser and the backscatter generates LW turbulence (LWT). Numerical simulations of SRS support the thesis that the LWT properties, such as various energy densities and enhanced LW decay rate, ν _eff, are determined primarily by ɛ, in the "inertial regime", where ν _eff>>ν_0, the linear rate, thus providing the basis for an SRS-LWT model. Energy conservation and turbulent stabilization of the SRS daughter LW against the decay instability imply that (ν_eff)^2>ω _pɛ /(16ν_ianT_e). Simulations reveal that, qualitatively, the inequality may be replaced by equality if the factor of 16 is replaced by 8.
The Impact of Monaural Beat Stimulation on Anxiety and Cognition.
Chaieb, Leila; Wilpert, Elke C; Hoppe, Christian; Axmacher, Nikolai; Fell, Juergen
2017-01-01
Application of auditory beat stimulation has been speculated to provide a promising new tool with which to alleviate symptoms of anxiety and to enhance cognition. In spite of reportedly similar EEG effects of binaural and monaural beats, data on behavioral effects of monaural beats are still lacking. Therefore, we examined the impact of monaural beat stimulation on anxiety, mood and memory performance. We aimed to target states related to anxiety levels and general well-being, in addition to long-term and working memory processes, using monaural beats within the range of main cortical rhythms. Theta (6 Hz), alpha (10 Hz) and gamma (40 Hz) beat frequencies, as well as a control stimulus were applied to healthy participants for 5 min. After each stimulation period, participants were asked to evaluate their current mood state and to perform cognitive tasks examining long-term and working memory processes, in addition to a vigilance task. Monaural beat stimulation was found to reduce state anxiety. When evaluating responses for the individual beat frequencies, positive effects on state anxiety were observed for all monaural beat conditions compared to control stimulation. Our results indicate a role for monaural beat stimulation in modulating state anxiety and are in line with previous studies reporting anxiety-reducing effects of auditory beat stimulation.
The Impact of Monaural Beat Stimulation on Anxiety and Cognition
Chaieb, Leila; Wilpert, Elke C.; Hoppe, Christian; Axmacher, Nikolai; Fell, Juergen
2017-01-01
Application of auditory beat stimulation has been speculated to provide a promising new tool with which to alleviate symptoms of anxiety and to enhance cognition. In spite of reportedly similar EEG effects of binaural and monaural beats, data on behavioral effects of monaural beats are still lacking. Therefore, we examined the impact of monaural beat stimulation on anxiety, mood and memory performance. We aimed to target states related to anxiety levels and general well-being, in addition to long-term and working memory processes, using monaural beats within the range of main cortical rhythms. Theta (6 Hz), alpha (10 Hz) and gamma (40 Hz) beat frequencies, as well as a control stimulus were applied to healthy participants for 5 min. After each stimulation period, participants were asked to evaluate their current mood state and to perform cognitive tasks examining long-term and working memory processes, in addition to a vigilance task. Monaural beat stimulation was found to reduce state anxiety. When evaluating responses for the individual beat frequencies, positive effects on state anxiety were observed for all monaural beat conditions compared to control stimulation. Our results indicate a role for monaural beat stimulation in modulating state anxiety and are in line with previous studies reporting anxiety-reducing effects of auditory beat stimulation. PMID:28555100
Fujii, Shinya; Schlaug, Gottfried
2013-01-01
Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session.
Fujii, Shinya; Schlaug, Gottfried
2013-01-01
Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session. PMID:24324421
Exploiting Concurrent Wake-Up Transmissions Using Beat Frequencies.
Kumberg, Timo; Schindelhauer, Christian; Reindl, Leonhard
2017-07-26
Wake-up receivers are the natural choice for wireless sensor networks because of their ultra-low power consumption and their ability to provide communications on demand. A downside of ultra-low power wake-up receivers is their low sensitivity caused by the passive demodulation of the carrier signal. In this article, we present a novel communication scheme by exploiting purposefully-interfering out-of-tune signals of two or more wireless sensor nodes, which produce the wake-up signal as the beat frequency of superposed carriers. Additionally, we introduce a communication algorithm and a flooding protocol based on this approach. Our experiments show that our approach increases the received signal strength up to 3 dB, improving communication robustness and reliability. Furthermore, we demonstrate the feasibility of our newly-developed protocols by means of an outdoor experiment and an indoor setup consisting of several nodes. The flooding algorithm achieves almost a 100% wake-up rate in less than 20 ms.
Bouwer, Fleur L; Werner, Carola M; Knetemann, Myrthe; Honing, Henkjan
2016-05-01
Beat perception is the ability to perceive temporal regularity in musical rhythm. When a beat is perceived, predictions about upcoming events can be generated. These predictions can influence processing of subsequent rhythmic events. However, statistical learning of the order of sounds in a sequence can also affect processing of rhythmic events and must be differentiated from beat perception. In the current study, using EEG, we examined the effects of attention and musical abilities on beat perception. To ensure we measured beat perception and not absolute perception of temporal intervals, we used alternating loud and soft tones to create a rhythm with two hierarchical metrical levels. To control for sequential learning of the order of the different sounds, we used temporally regular (isochronous) and jittered rhythmic sequences. The order of sounds was identical in both conditions, but only the regular condition allowed for the perception of a beat. Unexpected intensity decrements were introduced on the beat and offbeat. In the regular condition, both beat perception and sequential learning were expected to enhance detection of these deviants on the beat. In the jittered condition, only sequential learning was expected to affect processing of the deviants. ERP responses to deviants were larger on the beat than offbeat in both conditions. Importantly, this difference was larger in the regular condition than in the jittered condition, suggesting that beat perception influenced responses to rhythmic events in addition to sequential learning. The influence of beat perception was present both with and without attention directed at the rhythm. Moreover, beat perception as measured with ERPs correlated with musical abilities, but only when attention was directed at the stimuli. Our study shows that beat perception is possible when attention is not directed at a rhythm. In addition, our results suggest that attention may mediate the influence of musical abilities on beat perception. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
ERIC Educational Resources Information Center
Coulter, Stephen; Mullin, Anne
2012-01-01
This article focuses on the experience of one particular family living amid the sociopolitical violence in Northern Ireland to illustrate the impact of a particular traumatic event--a paramilitary assault due to mistaken identity. These attacks are often colloquially referred to as "punishment shootings" or "beatings." The…
Aesthetic Experience in the World of Visual Culture
ERIC Educational Resources Information Center
Moore, Ronald
2004-01-01
This article draws attention to three important aesthetic ideas--ideas which have become, in the early twenty-first century, so widely endorsed in Western culture that they have become the stock platform of much theorizing and teaching about our experience of art and its relation to the rest of life. All of these ideas sprang from Beat thought in…
NASA Astrophysics Data System (ADS)
Strekalov, Dmitry Vladimirovich
1997-10-01
The subject of this dissertation is the study of the two- photon entanglement. This phenomenon has been paid a great deal of attention since 1935, when A. Einstein, B. Podolsky and N. Rosen asked their famous question, 'Can quantum-mechanical description of physical reality be considered complete?' An entangled system behavior is inconsistent with many classical concepts. Therefore, the understanding of two-photon entanglement is important for the foundations of quantum theory. A two-photon entangled sate represents a two-photon, or a biphoton, rather than two photons. The concept of biphoton as a single nonlocal quantum object is fundamentally different from the concept of a photon pair, as has been experimentally demonstrated in the present dissertation. Two-photon entanglement gives rise to unusual 'ghost' interference and diffraction, nonlocal geometrical phase, and other quantum phenomena originally studied in the present dissertation. The variety of available results calls for bringing them into a general system which we call Biphoton Optics. This is the main goal of this dissertation. Biphoton optics operate with two-photon wave packets, or with an equivalent concept of advanced wave. We show that in the framework of the advanced wave concept two-photon phenomena can be effectively described in terms of classical optics. Therefore the biphoton optics has the same structure as the classical optics. It includes two- photon geometrical optics, dispersion and frequency beating, polarization effects, interference, diffraction, and geometrical phase. All these two-photon effects are represented by experiments included in this dissertation. Our approach does not make two-photon quantum effects 'classical', however. It should be understood that the advanced wave model operates with counter-propagation in time which does not correspond to any real physical process. Therefore it is just a model, but it is clearly a great advantage to have such a model that is both simple and powerful, in terms of its ability to describe the known results and accurately predict the new ones. Therefore an important step is made in understanding and describing of the quantum phenomena of two-photon entanglement.
Grahn, Jessica A.; Rowe, James B.
2009-01-01
Little is known about the underlying neurobiology of rhythm and beat perception, despite its universal cultural importance. Here we used functional magnetic resonance imaging to study rhythm perception in musicians and non-musicians. Three conditions varied in the degree to which external reinforcement versus internal generation of the beat was required. The ‘Volume’ condition strongly externally marked the beat with volume changes, the ‘Duration’ condition marked the beat with weaker accents arising from duration changes, and the ‘Unaccented’ condition required the beat to be entirely internally generated. In all conditions, beat rhythms compared to nonbeat control rhythms revealed putamen activity. The presence of a beat was also associated with greater connectivity between the putamen and the supplementary motor area (SMA), the premotor cortex (PMC) and auditory cortex. In contrast, the type of accent within the beat conditions modulated the coupling between premotor and auditory cortex, with greater modulation for musicians than non-musicians. Importantly, the putamen's response to beat conditions was not due to differences in temporal complexity between the three rhythm conditions. We propose that a cortico-subcortical network including the putamen, SMA, and PMC is engaged for the analysis of temporal sequences and prediction or generation of putative beats, especially under conditions that may require internal generation of the beat. The importance of this system for auditory-motor interaction and development of precisely timed movement is suggested here by its facilitation in musicians. PMID:19515922
Grahn, Jessica A; Rowe, James B
2009-06-10
Little is known about the underlying neurobiology of rhythm and beat perception, despite its universal cultural importance. Here we used functional magnetic resonance imaging to study rhythm perception in musicians and nonmusicians. Three conditions varied in the degree to which external reinforcement versus internal generation of the beat was required. The "volume" condition strongly externally marked the beat with volume changes, the "duration" condition marked the beat with weaker accents arising from duration changes, and the "unaccented" condition required the beat to be entirely internally generated. In all conditions, beat rhythms compared with nonbeat control rhythms revealed putamen activity. The presence of a beat was also associated with greater connectivity between the putamen and the supplementary motor area (SMA), the premotor cortex (PMC), and auditory cortex. In contrast, the type of accent within the beat conditions modulated the coupling between premotor and auditory cortex, with greater modulation for musicians than nonmusicians. Importantly, the response of the putamen to beat conditions was not attributable to differences in temporal complexity between the three rhythm conditions. We propose that a cortico-subcortical network including the putamen, SMA, and PMC is engaged for the analysis of temporal sequences and prediction or generation of putative beats, especially under conditions that may require internal generation of the beat. The importance of this system for auditory-motor interaction and development of precisely timed movement is suggested here by its facilitation in musicians.
NASA Astrophysics Data System (ADS)
Mitryk, Shawn; Mueller, Guido
The Laser Interferometer Space Antenna (LISA) is a space-based modified Michelson interfer-ometer designed to measure gravitational radiation in the frequency range from 30 uHz to 1 Hz. The interferometer measurement system (IMS) utilizes one-way laser phase measurements to cancel the laser phase noise, reconstruct the proof-mass motion, and extract the gravitational wave (GW) induced laser phase modulations in post-processing using a technique called time-delay interferometry (TDI). Unfortunately, there exist few hard-ware verification experiments of the IMS. The University of Florida LISA Interferometry Simulator (UFLIS) is designed to perform hardware-in-the-loop simulations of the LISA interferometry system, modeling the characteris-tics of the LISA mission as accurately as possible. This depends, first, on replicating the laser pre-stabilization by locking the laser phase to an ultra-stable Zerodur cavity length reference using the PDH locking method. Phase measurements of LISA-like photodetector beat-notes are taken using the UF-phasemeter (PM) which can measure the laser BN frequency to within an accuracy of 0.22 uHz. The inter-space craft (SC) laser links including the time-delay due to the 5 Gm light travel time along the LISA arms, the laser Doppler shifts due to differential SC motion, and the GW induced laser phase modulations are simulated electronically using the electronic phase delay (EPD) unit. The EPD unit replicates the laser field propagation between SC by measuring a photodetector beat-note frequency with the UF-phasemeter and storing the information in memory. After the requested delay time, the frequency information is added to a Doppler offset and a GW-like frequency modulation. The signal is then regenerated with the inter-SC laser phase affects applied. Utilizing these components, I will present the first complete TDI simulations performed using the UFLIS. The LISA model is presented along-side the simulation, comparing the generation and measurement of LISA-like signals. Phasemeter measurements are used in post-processing and combined in the linear combinations defined by TDI, thus, canceling the laser phase and phase-lock loop noise to extract the applied GW modulation buried under the noise. Nine order of magnitude common mode laser noise cancellation is achieved at a frequency of 1 mHz and the GW signal is clearly visible after the laser and PLL noise cancellation.
Hearing, feeling or seeing a beat recruits a supramodal network in the auditory dorsal stream.
Araneda, Rodrigo; Renier, Laurent; Ebner-Karestinos, Daniela; Dricot, Laurence; De Volder, Anne G
2017-06-01
Hearing a beat recruits a wide neural network that involves the auditory cortex and motor planning regions. Perceiving a beat can potentially be achieved via vision or even touch, but it is currently not clear whether a common neural network underlies beat processing. Here, we used functional magnetic resonance imaging (fMRI) to test to what extent the neural network involved in beat processing is supramodal, that is, is the same in the different sensory modalities. Brain activity changes in 27 healthy volunteers were monitored while they were attending to the same rhythmic sequences (with and without a beat) in audition, vision and the vibrotactile modality. We found a common neural network for beat detection in the three modalities that involved parts of the auditory dorsal pathway. Within this network, only the putamen and the supplementary motor area (SMA) showed specificity to the beat, while the brain activity in the putamen covariated with the beat detection speed. These results highlighted the implication of the auditory dorsal stream in beat detection, confirmed the important role played by the putamen in beat detection and indicated that the neural network for beat detection is mostly supramodal. This constitutes a new example of convergence of the same functional attributes into one centralized representation in the brain. © 2016 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Fast T Wave Detection Calibrated by Clinical Knowledge with Annotation of P and T Waves
Elgendi, Mohamed; Eskofier, Bjoern; Abbott, Derek
2015-01-01
Background There are limited studies on the automatic detection of T waves in arrhythmic electrocardiogram (ECG) signals. This is perhaps because there is no available arrhythmia dataset with annotated T waves. There is a growing need to develop numerically-efficient algorithms that can accommodate the new trend of battery-driven ECG devices. Moreover, there is also a need to analyze long-term recorded signals in a reliable and time-efficient manner, therefore improving the diagnostic ability of mobile devices and point-of-care technologies. Methods Here, the T wave annotation of the well-known MIT-BIH arrhythmia database is discussed and provided. Moreover, a simple fast method for detecting T waves is introduced. A typical T wave detection method has been reduced to a basic approach consisting of two moving averages and dynamic thresholds. The dynamic thresholds were calibrated using four clinically known types of sinus node response to atrial premature depolarization (compensation, reset, interpolation, and reentry). Results The determination of T wave peaks is performed and the proposed algorithm is evaluated on two well-known databases, the QT and MIT-BIH Arrhythmia databases. The detector obtained a sensitivity of 97.14% and a positive predictivity of 99.29% over the first lead of the validation databases (total of 221,186 beats). Conclusions We present a simple yet very reliable T wave detection algorithm that can be potentially implemented on mobile battery-driven devices. In contrast to complex methods, it can be easily implemented in a digital filter design. PMID:26197321
Cortical evoked potentials to an auditory illusion: binaural beats.
Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi
2009-08-01
To define brain activity corresponding to an auditory illusion of 3 and 6Hz binaural beats in 250Hz or 1000Hz base frequencies, and compare it to the sound onset response. Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000Hz to one ear and 3 or 6Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3Hz and 6Hz, in base frequencies of 250Hz and 1000Hz. Tones were 2000ms in duration and presented with approximately 1s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. All stimuli evoked tone-onset P(50), N(100) and P(200) components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P(50) had significantly different sources than the beats-evoked oscillations; and N(100) and P(200) sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp.
Cortical Evoked Potentials to an Auditory Illusion: Binaural Beats
Pratt, Hillel; Starr, Arnold; Michalewski, Henry J.; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi
2009-01-01
Objective: To define brain activity corresponding to an auditory illusion of 3 and 6 Hz binaural beats in 250 Hz or 1,000 Hz base frequencies, and compare it to the sound onset response. Methods: Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000 Hz to one ear and 3 or 6 Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3 Hz and 6 Hz, in base frequencies of 250 Hz and 1000 Hz. Tones were 2,000 ms in duration and presented with approximately 1 s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. Results: All stimuli evoked tone-onset P50, N100 and P200 components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P50 had significantly different sources than the beats-evoked oscillations; and N100 and P200 sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Conclusions: Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Significance: Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp. PMID:19616993
The effects of auditory stimulation with music on heart rate variability in healthy women.
Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de
2013-07-01
There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level.
The effects of auditory stimulation with music on heart rate variability in healthy women
Roque, Adriano L.; Valenti, Vitor E.; Guida, Heraldo L.; Campos, Mônica F.; Knap, André; Vanderlei, Luiz Carlos M.; Ferreira, Lucas L.; Ferreira, Celso; de Abreu, Luiz Carlos
2013-01-01
OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. CONCLUSION: We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level. PMID:23917660
Losing the beat: deficits in temporal coordination.
Palmer, Caroline; Lidji, Pascale; Peretz, Isabelle
2014-12-19
Tapping or clapping to an auditory beat, an easy task for most individuals, reveals precise temporal synchronization with auditory patterns such as music, even in the presence of temporal fluctuations. Most models of beat-tracking rely on the theoretical concept of pulse: a perceived regular beat generated by an internal oscillation that forms the foundation of entrainment abilities. Although tapping to the beat is a natural sensorimotor activity for most individuals, not everyone can track an auditory beat. Recently, the case of Mathieu was documented (Phillips-Silver et al. 2011 Neuropsychologia 49, 961-969. (doi:10.1016/j.neuropsychologia.2011.02.002)). Mathieu presented himself as having difficulty following a beat and exhibited synchronization failures. We examined beat-tracking in normal control participants, Mathieu, and a second beat-deaf individual, who tapped with an auditory metronome in which unpredictable perturbations were introduced to disrupt entrainment. Both beat-deaf cases exhibited failures in error correction in response to the perturbation task while exhibiting normal spontaneous motor tempi (in the absence of an auditory stimulus), supporting a deficit specific to perception-action coupling. A damped harmonic oscillator model was applied to the temporal adaptation responses; the model's parameters of relaxation time and endogenous frequency accounted for differences between the beat-deaf cases as well as the control group individuals.
Losing the beat: deficits in temporal coordination
Palmer, Caroline; Lidji, Pascale; Peretz, Isabelle
2014-01-01
Tapping or clapping to an auditory beat, an easy task for most individuals, reveals precise temporal synchronization with auditory patterns such as music, even in the presence of temporal fluctuations. Most models of beat-tracking rely on the theoretical concept of pulse: a perceived regular beat generated by an internal oscillation that forms the foundation of entrainment abilities. Although tapping to the beat is a natural sensorimotor activity for most individuals, not everyone can track an auditory beat. Recently, the case of Mathieu was documented (Phillips-Silver et al. 2011 Neuropsychologia 49, 961–969. (doi:10.1016/j.neuropsychologia.2011.02.002)). Mathieu presented himself as having difficulty following a beat and exhibited synchronization failures. We examined beat-tracking in normal control participants, Mathieu, and a second beat-deaf individual, who tapped with an auditory metronome in which unpredictable perturbations were introduced to disrupt entrainment. Both beat-deaf cases exhibited failures in error correction in response to the perturbation task while exhibiting normal spontaneous motor tempi (in the absence of an auditory stimulus), supporting a deficit specific to perception–action coupling. A damped harmonic oscillator model was applied to the temporal adaptation responses; the model's parameters of relaxation time and endogenous frequency accounted for differences between the beat-deaf cases as well as the control group individuals. PMID:25385783
Zuk, Nathaniel J.; Carney, Laurel H.; Lalor, Edmund C.
2018-01-01
Prior research has shown that musical beats are salient at the level of the cortex in humans. Yet below the cortex there is considerable sub-cortical processing that could influence beat perception. Some biases, such as a tempo preference and an audio frequency bias for beat timing, could result from sub-cortical processing. Here, we used models of the auditory-nerve and midbrain-level amplitude modulation filtering to simulate sub-cortical neural activity to various beat-inducing stimuli, and we used the simulated activity to determine the tempo or beat frequency of the music. First, irrespective of the stimulus being presented, the preferred tempo was around 100 beats per minute, which is within the range of tempi where tempo discrimination and tapping accuracy are optimal. Second, sub-cortical processing predicted a stronger influence of lower audio frequencies on beat perception. However, the tempo identification algorithm that was optimized for simple stimuli often failed for recordings of music. For music, the most highly synchronized model activity occurred at a multiple of the beat frequency. Using bottom-up processes alone is insufficient to produce beat-locked activity. Instead, a learned and possibly top-down mechanism that scales the synchronization frequency to derive the beat frequency greatly improves the performance of tempo identification. PMID:29896080
Webb, Alastair J S; Mazzucco, Sara; Li, Linxin; Rothwell, Peter M
2018-01-01
Visit-to-visit and day-to-day blood pressure (BP) variability (BPV) predict an increased risk of cardiovascular events but only reflect 1 form of BPV. Beat-to-beat BPV can be rapidly assessed and might also be predictive. In consecutive patients within 6 weeks of transient ischemic attack or nondisabling stroke (Oxford Vascular Study), BPV (coefficient of variation) was measured beat-to-beat for 5 minutes (Finometer), day-to-day for 1 week on home monitoring (3 readings, 3× daily), and on awake ambulatory BP monitoring. BPV after 1-month standard treatment was related (Cox proportional hazards) to recurrent stroke and cardiovascular events for 2 to 5 years, adjusted for mean systolic BP. Among 520 patients, 26 had inadequate beat-to-beat recordings, and 22 patients were in atrial fibrillation. Four hundred five patients had all forms of monitoring. Beat-to-beat BPV predicted recurrent stroke and cardiovascular events independently of mean systolic BP (hazard ratio per group SD, stroke: 1.47 [1.12-1.91]; P =0.005; cardiovascular events: 1.41 [1.08-1.83]; P =0.01), including after adjustment for age and sex (stroke: 1.47 [1.12-1.92]; P =0.005) and all risk factors (1.40 [1.00-1.94]; P =0.047). Day-to-day BPV was less strongly associated with stroke (adjusted hazard ratio, 1.29 [0.97-1.71]; P =0.08) but similarly with cardiovascular events (1.41 [1.09-1.83]; P =0.009). BPV on awake ambulatory BP monitoring was nonpredictive (stroke: 0.89 [0.59-1.35]; P =0.59; cardiovascular events: 1.08 [0.77-1.52]; P =0.65). Despite a weak correlation ( r =0.119; P =0.02), beat-to-beat BPV was associated with risk of recurrent stroke independently of day-to-day BPV (1.41 [1.05-1.90]; P =0.02). Beat-to-beat BPV predicted recurrent stroke and cardiovascular events, independently of mean systolic BP and risk factors but short-term BPV on ambulatory BP monitoring did not. Beat-to-beat BPV may be a useful additional marker of cardiovascular risk. © 2017 The Authors.
Beliefs of Sri Lankan Medical Students about Wife Beating
ERIC Educational Resources Information Center
Haj-Yahia, Muhammad M.; de Zoysa, Piyanjali
2007-01-01
The article presents the results of a study on beliefs about wife beating conducted among 476 Sri Lankan medical students. Participants fill out a self-administered questionnaire, which examines six beliefs about wife beating. Most students tend to justify wife beating, to believe women benefit from wife beating, and to believe the wife bears more…
Effects of atomoxetine on heart rhythm in children and adolescents.
Tanidir, Ibrahim Cansaran; Tanidir, Canan; Ozturk, Erkut; Bahali, Kayhan; Gunes, Hatice; Ergul, Yakup; Uneri, Ozden Sukran; Akdeniz, Celal; Tuzcu, Volkan
2015-12-01
The aim of this study was to examine the effects of atomoxetine on heart rhythm using 12-lead electrocardiography (ECG) and 24 h Holter monitoring. Children and adolescents who were diagnosed with attention deficit-hyperactivity disorder according to DSM-IV-TR were referred to a pediatric cardiology clinic for cardiologic examination before and after 4 or 5 weeks of atomoxetine treatment. Cardiac examination, complete blood count, biochemistry, thyroid function tests, 12-lead ECG and 24 h Holter monitoring were performed routinely in all patients. Each subject underwent 24 h Holter ECG monitoring before atomoxetine was started and after 4 or 5 weeks of effective dose atomoxetine treatment. Forty-one patients were included in this prospective study. No statistically significant change was found in QT, QTc or QT interval dispersion or blood pressure before and after 4 or 5 weeks of atomoxetine treatment. There was a statistically significant increase in heart rate (both during the day and at night) and QRS duration, and a statistically significant decrease in P wave dispersion. Three patients had rhythm disturbances. All of these three patients were asymptomatic and none of these arrhythmias reached clinical significance. Atomoxetine did not cause significant changes in ECG or Holter variables. In two patients, who had undiagnosed subclinical extrasystoles, extra beats were increased after 4th week of treatment, but still remained clinically insignificant. Before and after atomoxetine treatment, listening to the heart sounds for a longer time, may help clinicians to notice an extra beat. If an extra beat is identified then 24 Holter monitoring is recommended. © 2015 Japan Pediatric Society.
Keeping the Beat: A Large Sample Study of Bouncing and Clapping to Music
Tranchant, Pauline; Vuvan, Dominique T.; Peretz, Isabelle
2016-01-01
The vast majority of humans move in time with a musical beat. This behaviour has been mostly studied through finger-tapping synchronization. Here, we evaluate naturalistic synchronization responses to music–bouncing and clapping–in 100 university students. Their ability to match the period of their bounces and claps to those of a metronome and musical clips varying in beat saliency was assessed. In general, clapping was better synchronized with the beat than bouncing, suggesting that the choice of a specific movement type is an important factor to consider in the study of sensorimotor synchronization processes. Performance improved as a function of beat saliency, indicating that beat abstraction plays a significant role in synchronization. Fourteen percent of the population exhibited marked difficulties with matching the beat. Yet, at a group level, poor synchronizers showed similar sensitivity to movement type and beat saliency as normal synchronizers. These results suggest the presence of quantitative rather than qualitative variations when losing the beat. PMID:27471854
Midbrain adaptation may set the stage for the perception of musical beat
2017-01-01
The ability to spontaneously feel a beat in music is a phenomenon widely believed to be unique to humans. Though beat perception involves the coordinated engagement of sensory, motor and cognitive processes in humans, the contribution of low-level auditory processing to the activation of these networks in a beat-specific manner is poorly understood. Here, we present evidence from a rodent model that midbrain preprocessing of sounds may already be shaping where the beat is ultimately felt. For the tested set of musical rhythms, on-beat sounds on average evoked higher firing rates than off-beat sounds, and this difference was a defining feature of the set of beat interpretations most commonly perceived by human listeners over others. Basic firing rate adaptation provided a sufficient explanation for these results. Our findings suggest that midbrain adaptation, by encoding the temporal context of sounds, creates points of neural emphasis that may influence the perceptual emergence of a beat. PMID:29118141
Midbrain adaptation may set the stage for the perception of musical beat.
Rajendran, Vani G; Harper, Nicol S; Garcia-Lazaro, Jose A; Lesica, Nicholas A; Schnupp, Jan W H
2017-11-15
The ability to spontaneously feel a beat in music is a phenomenon widely believed to be unique to humans. Though beat perception involves the coordinated engagement of sensory, motor and cognitive processes in humans, the contribution of low-level auditory processing to the activation of these networks in a beat-specific manner is poorly understood. Here, we present evidence from a rodent model that midbrain preprocessing of sounds may already be shaping where the beat is ultimately felt. For the tested set of musical rhythms, on-beat sounds on average evoked higher firing rates than off-beat sounds, and this difference was a defining feature of the set of beat interpretations most commonly perceived by human listeners over others. Basic firing rate adaptation provided a sufficient explanation for these results. Our findings suggest that midbrain adaptation, by encoding the temporal context of sounds, creates points of neural emphasis that may influence the perceptual emergence of a beat. © 2017 The Authors.
Effect of muscle mass and intensity of isometric contraction on heart rate.
Gálvez, J M; Alonso, J P; Sangrador, L A; Navarro, G
2000-02-01
The purpose of this study was to determine the effect of muscle mass and the level of force on the contraction-induced rise in heart rate. We conducted an experimental study in a sample of 28 healthy men between 20 and 30 yr of age (power: 95%, alpha: 5%). Smokers, obese subjects, and those who performed regular physical activity over a certain amount of energetic expenditure were excluded from the study. The participants exerted two types of isometric contractions: handgrip and turning a 40-cm-diameter wheel. Both were sustained to exhaustion at 20 and 50% of maximal force. Twenty-five subjects finished the experiment. Heart rate increased a mean of 15.1 beats/min [95% confidence interval (CI): 5.5-24.6] from 20 to 50% handgrip contractions, and 20.7 beats/min (95% CI: 11.9-29.5) from 20 to 50% wheel-turn contractions. Heart rate also increased a mean of 13.3 beats/min (95% CI: 10.4-16.1) from handgrip to wheel-turn contractions at 20% maximal force, and 18.9 beats/min (95% CI: 9. 8-28.0) from handgrip to wheel-turn contractions at 50% maximal force. We conclude that the magnitude of the heart rate increase during isometric exercise is related to the intensity of the contraction and the mass of the contracted muscle.
The Effect of Binaural Beats on Visuospatial Working Memory and Cortical Connectivity.
Beauchene, Christine; Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A; Leonessa, Alexander
2016-01-01
Binaural beats utilize a phenomenon that occurs within the cortex when two different frequencies are presented separately to each ear. This procedure produces a third phantom binaural beat, whose frequency is equal to the difference of the two presented tones and which can be manipulated for non-invasive brain stimulation. The effects of binaural beats on working memory, the system in control of temporary retention and online organization of thoughts for successful goal directed behavior, have not been well studied. Furthermore, no studies have evaluated the effects of binaural beats on brain connectivity during working memory tasks. In this study, we determined the effects of different acoustic stimulation conditions on participant response accuracy and cortical network topology, as measured by EEG recordings, during a visuospatial working memory task. Three acoustic stimulation control conditions and three binaural beat stimulation conditions were used: None, Pure Tone, Classical Music, 5Hz binaural beats, 10Hz binaural beats, and 15Hz binaural beats. We found that listening to 15Hz binaural beats during a visuospatial working memory task not only increased the response accuracy, but also modified the strengths of the cortical networks during the task. The three auditory control conditions and the 5Hz and 10Hz binaural beats all decreased accuracy. Based on graphical network analyses, the cortical activity during 15Hz binaural beats produced networks characteristic of high information transfer with consistent connection strengths throughout the visuospatial working memory task.
The Effect of Binaural Beats on Visuospatial Working Memory and Cortical Connectivity
Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A.; Leonessa, Alexander
2016-01-01
Binaural beats utilize a phenomenon that occurs within the cortex when two different frequencies are presented separately to each ear. This procedure produces a third phantom binaural beat, whose frequency is equal to the difference of the two presented tones and which can be manipulated for non-invasive brain stimulation. The effects of binaural beats on working memory, the system in control of temporary retention and online organization of thoughts for successful goal directed behavior, have not been well studied. Furthermore, no studies have evaluated the effects of binaural beats on brain connectivity during working memory tasks. In this study, we determined the effects of different acoustic stimulation conditions on participant response accuracy and cortical network topology, as measured by EEG recordings, during a visuospatial working memory task. Three acoustic stimulation control conditions and three binaural beat stimulation conditions were used: None, Pure Tone, Classical Music, 5Hz binaural beats, 10Hz binaural beats, and 15Hz binaural beats. We found that listening to 15Hz binaural beats during a visuospatial working memory task not only increased the response accuracy, but also modified the strengths of the cortical networks during the task. The three auditory control conditions and the 5Hz and 10Hz binaural beats all decreased accuracy. Based on graphical network analyses, the cortical activity during 15Hz binaural beats produced networks characteristic of high information transfer with consistent connection strengths throughout the visuospatial working memory task. PMID:27893766
Condensed-matter physics: Marching to a different quantum beat
NASA Astrophysics Data System (ADS)
Nayak, Chetan
2017-03-01
Periodic oscillations are common in nature but they generally decay or fall out of phase. Two experiments have found evidence for a Floquet time crystal, which is characterized by persistent in-phase oscillations. See Letters p.217 & p. 221
Preparing hearts and minds: cardiac slowing and a cortical inhibitory network.
Jennings, J R; van der Molen, M W; Tanase, C
2009-11-01
Preparing for a cued, speeded response induces a set of physiological changes. A review of the psychophysiology of preparation suggested that inhibition of action was an important process among the constellation of changes constituting attentive preparation. The current experiment combined event-related functional magnetic resonance imaging and cardiac inter-beat interval measures in an experiment that compared preparing for a response, watching stimuli without responding, and responding in the absence of preparation. Ten college-aged participants were tested in an initial psychophysiological experiment followed by two scanning sessions during which reverse spiral imaging was performed concurrent with inter-beat interval measurement. Two analytic approaches were used to confirm blood oxygenation level dependent responses during preparation, and these converged to show inferior prefrontal and related subthalamic nuclei activity in the context of other known changes related to brain attentional networks. Subthalamic nuclei changes were related to the depth of preparatory cardiac deceleration. This pattern of findings suggests that preparation involves the activation of a complex inhibitory neural network implicating brain and autonomic nervous systems.
Flethøj, Mette; Kanters, Jørgen K; Pedersen, Philip J; Haugaard, Maria M; Carstensen, Helena; Olsen, Lisbeth H; Buhl, Rikke
2016-11-28
Although premature beats are a matter of concern in horses, the interpretation of equine ECG recordings is complicated by a lack of standardized analysis criteria and a limited knowledge of the normal beat-to-beat variation of equine cardiac rhythm. The purpose of this study was to determine the appropriate threshold levels of maximum acceptable deviation of RR intervals in equine ECG analysis, and to evaluate a novel two-step timing algorithm by quantifying the frequency of arrhythmias in a cohort of healthy adult endurance horses. Beat-to-beat variation differed considerably with heart rate (HR), and an adaptable model consisting of three different HR ranges with separate threshold levels of maximum acceptable RR deviation was consequently defined. For resting HRs <60 beats/min (bpm) the threshold level of RR deviation was set at 20%, for HRs in the intermediate range between 60 and 100 bpm the threshold was 10%, and for exercising HRs >100 bpm, the threshold level was 4%. Supraventricular premature beats represented the most prevalent arrhythmia category with varying frequencies in seven horses at rest (median 7, range 2-86) and six horses during exercise (median 2, range 1-24). Beat-to-beat variation of equine cardiac rhythm varies according to HR, and threshold levels in equine ECG analysis should be adjusted accordingly. Standardization of the analysis criteria will enable comparisons of studies and follow-up examinations of patients. A small number of supraventricular premature beats appears to be a normal finding in endurance horses. Further studies are required to validate the findings and determine the clinical significance of premature beats in horses.
Rani, Manju; Bonu, Sekhar; Diop-Sidibe, Nafissatou
2004-12-01
This study used data from the demographic and health surveys (DHS) conducted between 1999 and 2001 in Benin, Ethiopia, Malawi, Mali, Rwanda, Uganda and Zimbabwe, to examine the magnitude and correlates of conditional acceptance of wife-beating among both men and women. Multivariate logistic regression models were fitted to investigate the independent association between different socio-demographic characteristics and acceptance of wife-beating. The acceptance of wife-beating for transgressing certain gender roles was widespread in all the countries. Men were consistently less likely to justify wife-beating than women. Household wealth and education emerged as strongest and most consistent negative predictors of acceptance of wife-beating among both men and women. Older men and women were less likely to justify wife-beating. Men and women in the polygamous union were more likely to accept wife-beating, though the association was not always significant. With the exception of Uganda, women working for pay were more likely to justify wife-beating than non-working women were. The results indicate that dominant social and cultural norms create images of "ideal" women among both men and women that include definition and widespread acceptance of gender roles as well as sanction use of force to enforce these gender roles. The State and its different institutions may fail to mitigate wife-beating, as sensitivity to objectively address wife-beating may be tellingly lacking. Though education, economic growth, etc, can reduce acceptance of wife-beating, the process may be too slow and too late to make a substantial difference in the near future. Proactive measures may be required to change attitudes towards wife-beating among both men and women.
Coherent electron{endash}hole correlations in quantum dots
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joensson, L.; Steiner, M.M.; Wilkins, J.W.
1997-03-01
Using numerical time propagation of the electron{endash}hole wave function, we demonstrate how various coherent correlation effects can be observed by laser excitation of a nanoscale semiconductor quantum dot. The lowest-lying states of an electron{endash}hole pair, when appropriately excited by a laser pulse, give rise to charge oscillations that are manifested by beatings in the optical or intraband polarizations. A GaAs 5{times}25{times}25 nm{sup 3} dot in the effective-mass approximation, including the screened Coulomb interaction between the electron and a heavy or light hole, is simulated. {copyright} {ital 1997 American Institute of Physics.}
Enami, Yuta; Joseph, Brigid; Bandi, Sriram; Lin, Juan; Gupta, Sanjeev
2012-04-01
Organs from non-heart-beating donors are attractive for use in cell therapy. Understanding the nature of molecular perturbations following reperfusion/reoxygenation will be highly significant for non-heart-beating donor cells. We studied non-heart-beating donor rats for global gene expression with Affymetrix microarrays, hepatic tissue integrity, viability of isolated hepatocytes, and engraftment and proliferation of transplanted cells in dipeptidyl peptidase IV-deficient rats. In non-heart-beating donors, liver tissue was morphologically intact for >24 hours with differential expression of 1, 95, or 372 genes, 4, 16, or 34 hours after death, respectively, compared with heart-beating donors. These differentially expressed genes constituted prominent groupings in ontological pathways of oxidative phosphorylation, adherence junctions, glycolysis/gluconeogenesis, and other discrete pathways. We successfully isolated viable hepatocytes from non-heart-beating donors, especially up to 4 hours after death, although the hepatocyte yield and viability were inferior to those of hepatocytes from heart-beating donors (P < 0.05). Similarly, although hepatocytes from non-heart-beating donors engrafted and proliferated after transplantation in recipient animals, this was inferior to hepatocytes from heart-beating donors (P < 0.05). Gene expression profiling in hepatocytes isolated from non-heart-beating donors showed far greater perturbations compared with corresponding liver tissue, including representation of pathways in focal adhesion, actin cytoskeleton, extracellular matrix-receptor interactions, multiple ligand-receptor interactions, and signaling in insulin, calcium, wnt, Jak-Stat, or other cascades. Liver tissue remained intact over prolonged periods after death in non-heart-beating donors, but extensive molecular perturbations following reperfusion/reoxygenation impaired the viability of isolated hepatocytes from these donors. Insights into molecular changes in hepatocytes from non-heart-beating donors offer opportunities for improving donor cell viability, which will advance the utility of non-heart-beating donor organs for cell therapy or other applications. Copyright © 2012 American Association for the Study of Liver Diseases.
Multitarget detection algorithm for automotive FMCW radar
NASA Astrophysics Data System (ADS)
Hyun, Eugin; Oh, Woo-Jin; Lee, Jong-Hun
2012-06-01
Today, 77 GHz FMCW (Frequency Modulation Continuous Wave) radar has strong advantages of range and velocity detection for automotive applications. However, FMCW radar brings out ghost targets and missed targets in multi-target situations. In this paper, in order to resolve these limitations, we propose an effective pairing algorithm, which consists of two steps. In the proposed method, a waveform with different slopes in two periods is used. In the 1st pairing processing, all combinations of range and velocity are obtained in each of two wave periods. In the 2nd pairing step, using the results of the 1st pairing processing, fine range and velocity are detected. In that case, we propose the range-velocity windowing technique in order to compensate for the non-ideal beat-frequency characteristic that arises due to the non-linearity of the RF module. Based on experimental results, the performance of the proposed algorithm is improved compared with that of the typical method.
Flag-based detection of weak gas signatures in long-wave infrared hyperspectral image sequences
NASA Astrophysics Data System (ADS)
Marrinan, Timothy; Beveridge, J. Ross; Draper, Bruce; Kirby, Michael; Peterson, Chris
2016-05-01
We present a flag manifold based method for detecting chemical plumes in long-wave infrared hyperspectral movies. The method encodes temporal and spatial information related to a hyperspectral pixel into a flag, or nested sequence of linear subspaces. The technique used to create the flags pushes information about the background clutter, ambient conditions, and potential chemical agents into the leading elements of the flags. Exploiting this temporal information allows for a detection algorithm that is sensitive to the presence of weak signals. This method is compared to existing techniques qualitatively on real data and quantitatively on synthetic data to show that the flag-based algorithm consistently performs better on data when the SINRdB is low, and beats the ACE and MF algorithms in probability of detection for low probabilities of false alarm even when the SINRdB is high.
Significance of beating observed in earthquake responses of buildings
Çelebi, Mehmet; Ghahari, S. F.; Taciroglu, E.
2016-01-01
The beating phenomenon observed in the recorded responses of a tall building in Japan and another in the U.S. are examined in this paper. Beating is a periodic vibrational behavior caused by distinctive coupling between translational and torsional modes that typically have close frequencies. Beating is prominent in the prolonged resonant responses of lightly damped structures. Resonances caused by site effects also contribute to accentuating the beating effect. Spectral analyses and system identification techniques are used herein to quantify the periods and amplitudes of the beating effects from the strong motion recordings of the two buildings. Quantification of beating effects is a first step towards determining remedial actions to improve resilient building performance to strong earthquake induced shaking.
The Effect of Aortic Compliance on Left Ventricular Power Requirement
NASA Astrophysics Data System (ADS)
Pahlevan, Niema; Gharib, Morteza
2009-11-01
Aortic compliance depends on both geometry and mechanical properties of the aorta. Reduction in arterial compliance has been associated with aging, smoking, and multiple cardiovascular diseases. Increased stiffness of the aorta affects the wave dynamics in the aorta by increasing both pulse pressure amplitude and wave speed. We hypothesized that decreased aortic compliance leads to an increased left ventricular power requirement for a fixed cardiac output due to altered pulse pressure and pulse wave velocity. We used a computational approach using the finite element method for solid and fluid domains coupled to each other by using the direct coupling method. A nonlinear material model was used for the solid wall. The fluid flow model was considered to be Newtonian, incompressible, and laminar. The simulation was performed for a heart rate of 75 beats per minute for six different compliances while keeping the cardiac output and the peripheral resistance constant. The results show a trend towards increased left ventricular energy expenditure per cycle with decreased compliance. The relevance of these findings to clinical observations will be discussed.
Search for continuous gravitational waves from neutron stars in globular cluster NGC 6544
NASA Astrophysics Data System (ADS)
Abbott, B. P.; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Aiello, L.; Ain, A.; Allen, B.; Allocca, A.; Altin, P. A.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C. C.; Areeda, J. S.; Arnaud, N.; Arun, K. G.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Babak, S.; Bacon, P.; Bader, M. K. M.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Baune, C.; Bavigadda, V.; Bazzan, M.; Bejger, M.; Bell, A. S.; Berger, B. K.; Bergmann, G.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Birney, R.; Biscans, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, S.; Bock, O.; Boer, M.; Bogaert, G.; Bogan, C.; Bohe, A.; Bond, C.; Bondu, F.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Broida, J. E.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brown, N. M.; Brunett, S.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cabero, M.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Calderón Bustillo, J.; Callister, T.; Calloni, E.; Camp, J. B.; Cannon, K. C.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Casanueva Diaz, J.; Casentini, C.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Cerboni Baiardi, L.; Cerretani, G.; Cesarini, E.; Chamberlin, S. J.; Chan, M.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Cheeseboro, B. D.; Chen, H. Y.; Chen, Y.; Cheng, C.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, S.; Chung, S.; Ciani, G.; Clara, F.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Collette, C. G.; Cominsky, L.; Constancio, M.; Conte, A.; Conti, L.; Cook, D.; Corbitt, T. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, C. A.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J.-P.; Countryman, S. T.; Couvares, P.; Cowan, E. E.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Craig, K.; Creighton, J. D. E.; Creighton, T.; Cripe, J.; Crowder, S. G.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dal Canton, T.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Darman, N. S.; Dasgupta, A.; Da Silva Costa, C. F.; Dattilo, V.; Dave, I.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; De, S.; DeBra, D.; Debreczeni, G.; Degallaix, J.; De Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; DeSalvo, R.; Devine, R. C.; Dhurandhar, S.; Díaz, M. C.; Di Fiore, L.; Di Giovanni, M.; Di Girolamo, T.; Di Lieto, A.; Di Pace, S.; Di Palma, I.; Di Virgilio, A.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Douglas, R.; Downes, T. P.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Ducrot, M.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Engels, W.; Essick, R. C.; Etzel, T.; Evans, M.; Evans, T. M.; Everett, R.; Factourovich, M.; Fafone, V.; Fair, H.; Fan, X.; Fang, Q.; Farinon, S.; Farr, B.; Farr, W. M.; Favata, M.; Fays, M.; Fehrmann, H.; Fejer, M. M.; Fenyvesi, E.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Fiori, I.; Fiorucci, D.; Fisher, R. P.; Flaminio, R.; Fletcher, M.; Fournier, J.-D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H. A. G.; Gair, J. R.; Gammaitoni, L.; Gaonkar, S. G.; Garufi, F.; Gaur, G.; Gehrels, N.; Gemme, G.; Geng, P.; Genin, E.; Gennai, A.; George, J.; Gergely, L.; Germain, V.; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.; Glaefke, A.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gonzalez Castro, J. M.; Gopakumar, A.; Gordon, N. A.; Gorodetsky, M. L.; Gossan, S. E.; Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Green, A. C.; Groot, P.; Grote, H.; Grunewald, S.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Hacker, J. J.; Hall, B. R.; Hall, E. D.; Hammond, G.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Hartman, M. T.; Haster, C.-J.; Haughian, K.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Henry, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hoak, D.; Hofman, D.; Holt, K.; Holz, D. E.; Hopkins, P.; Hough, J.; Houston, E. A.; Howell, E. J.; Hu, Y. M.; Huang, S.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Indik, N.; Ingram, D. R.; Inta, R.; Isa, H. N.; Isac, J.-M.; Isi, M.; Isogai, T.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jang, H.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jian, L.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Haris, K.; Kalaghatgi, C. V.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kapadia, S. J.; Karki, S.; Karvinen, K. S.; Kasprzack, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kaur, T.; Kawabe, K.; Kéfélian, F.; Kehl, M. S.; Keitel, D.; Kelley, D. B.; Kells, W.; Kennedy, R.; Key, J. S.; Khalili, F. Y.; Khan, I.; Khan, S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chi-Woong; Kim, Chunglee; Kim, J.; Kim, K.; Kim, N.; Kim, W.; Kim, Y.-M.; Kimbrell, S. J.; King, E. J.; King, P. J.; Kissel, J. S.; Klein, B.; Kleybolte, L.; Klimenko, S.; Koehlenbeck, S. M.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Kringel, V.; Krishnan, B.; Królak, A.; Krueger, C.; Kuehn, G.; Kumar, P.; Kumar, R.; Kuo, L.; Kutynia, A.; Lackey, B. D.; Landry, M.; Lange, J.; Lantz, B.; Lasky, P. D.; Laxen, M.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lebigot, E. O.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Lee, K.; Lenon, A.; Leonardi, M.; Leong, J. R.; Leroy, N.; Letendre, N.; Levin, Y.; Lewis, J. B.; Li, T. G. F.; Libson, A.; Littenberg, T. B.; Lockerbie, N. A.; Lombardi, A. L.; London, L. T.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lück, H.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magaña-Sandoval, F.; Magaña Zertuche, L.; Magee, R. M.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A. S.; Maros, E.; Martelli, F.; Martellini, L.; Martin, I. W.; Martynov, D. V.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McRae, T.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Meidam, J.; Melatos, A.; Mendell, G.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Mezzani, F.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, A.; Miller, B. B.; Miller, J.; Millhouse, M.; Minenkov, Y.; Ming, J.; Mirshekari, S.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moggi, A.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, B. C.; Moore, C. J.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, D.; Mukherjee, S.; Mukund, N.; Mullavey, A.; Munch, J.; Murphy, D. J.; Murray, P. G.; Mytidis, A.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Nedkova, K.; Nelemans, G.; Nelson, T. J. N.; Neri, M.; Neunzert, A.; Newton, G.; Nguyen, T. T.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E. N.; Nuttall, L. K.; Oberling, J.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oliver, M.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; O'Shaughnessy, R.; Ottaway, D. J.; Overmier, H.; Owen, B. J.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Paris, H. R.; Parker, W.; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patel, P.; Patricelli, B.; Patrick, Z.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Perreca, A.; Perri, L. M.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Poe, M.; Poggiani, R.; Popolizio, P.; Post, A.; Powell, J.; Prasad, J.; Predoi, V.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prix, R.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qi, H.; Qin, J.; Qiu, S.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rajan, C.; Rakhmanov, M.; Rapagnani, P.; Raymond, V.; Razzano, M.; Re, V.; Read, J.; Reed, C. M.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Rew, H.; Reyes, S. D.; Ricci, F.; Riles, K.; Rizzo, M.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, R.; Romanov, G.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Sakellariadou, M.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sanchez, E. J.; Sandberg, V.; Sandeen, B.; Sanders, J. R.; Sassolas, B.; Saulson, P. R.; Sauter, O. E. S.; Savage, R. L.; Sawadsky, A.; Schale, P.; Schilling, R.; Schmidt, J.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schönbeck, A.; Schreiber, E.; Schuette, D.; Schutz, B. F.; Scott, J.; Scott, S. M.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Setyawati, Y.; Shaddock, D. A.; Shaffer, T.; Shahriar, M. S.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, A. D.; Singer, A.; Singer, L. P.; Singh, A.; Singh, R.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, J. R.; Smith, N. D.; Smith, R. J. E.; Son, E. J.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Srivastava, A. K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stephens, B. C.; Stone, R.; Strain, K. A.; Straniero, N.; Stratta, G.; Strauss, N. A.; Strigin, S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sunil, S.; Sutton, P. J.; Swinkels, B. L.; Szczepańczyk, M. J.; Tacca, M.; Talukder, D.; Tanner, D. B.; Tápai, M.; Tarabrin, S. P.; Taracchini, A.; Taylor, R.; Theeg, T.; Thirugnanasambandam, M. P.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thrane, E.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Toland, K.; Tomlinson, C.; Tonelli, M.; Tornasi, Z.; Torres, C. V.; Torrie, C. I.; Töyrä, D.; Travasso, F.; Traylor, G.; Trifirò, D.; Tringali, M. C.; Trozzo, L.; Tse, M.; Turconi, M.; Tuyenbayev, D.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; Van Den Broeck, C.; Vander-Hyde, D. C.; van der Schaaf, L.; van Heijningen, J. V.; van Veggel, A. A.; Vardaro, M.; Vass, S.; Vasúth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Vetrano, F.; Viceré, A.; Vinciguerra, S.; Vine, D. J.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Voss, D. V.; Vousden, W. D.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, M.; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, M.; Wang, X.; Wang, Y.; Ward, R. L.; Warner, J.; Was, M.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Weßels, P.; Westphal, T.; Wette, K.; Whelan, J. T.; Whiting, B. F.; Williams, R. D.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Woehler, J.; Worden, J.; Wright, J. L.; Wu, D. S.; Wu, G.; Yablon, J.; Yam, W.; Yamamoto, H.; Yancey, C. C.; Yu, H.; Yvert, M.; ZadroŻny, A.; Zangrando, L.; Zanolin, M.; Zendri, J.-P.; Zevin, M.; Zhang, L.; Zhang, M.; Zhang, Y.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, X. J.; Zucker, M. E.; Zuraw, S. E.; Zweizig, J.; Sigurdsson, S.; LIGO Scientific Collaboration; Virgo Collaboration
2017-04-01
We describe a directed search for continuous gravitational waves in data from the sixth initial LIGO science run. The target was the nearby globular cluster NGC 6544 at a distance of ≈2.7 kpc . The search covered a broad band of frequencies along with first and second frequency derivatives for a fixed sky position. The search coherently integrated data from the two LIGO interferometers over a time span of 9.2 days using the matched-filtering F -statistic. We found no gravitational-wave signals and set 95% confidence upper limits as stringent as 6.0 ×10-25 on intrinsic strain and 8.5 ×10-6 on fiducial ellipticity. These values beat the indirect limits from energy conservation for stars with characteristic spin-down ages older than 300 years and are within the range of theoretical predictions for possible neutron-star ellipticities. An important feature of this search was use of a barycentric resampling algorithm which substantially reduced computational cost; this method is used extensively in searches of Advanced LIGO and Virgo detector data.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, III, Robert A. (Inventor)
1996-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, Robert A., III (Inventor)
1994-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate is presented. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm.
Olbers, Joakim; Gille, Adam; Ljungman, Petter; Rosenqvist, Mårten; Östergren, Jan; Witt, Nils
2018-02-07
Atrial fibrillation (AF) is associated with an increased risk for cardiovascular morbidity and mortality, not entirely explained by thromboembolism. The underlying mechanisms for this association are largely unknown. Similarly, high blood pressure (BP) increases the risk for cardiovascular events. Despite this the interplay between AF and BP is insufficiently studied. The purpose of this study was to examine and quantify the beat-to-beat blood pressure variability in patients with AF in comparison to a control group of patients with sinus rhythm. We studied 33 patients - 21 in atrial fibrillation and 12 in sinus rhythm - undergoing routine coronary angiography. Invasive blood pressure was recorded at three locations: radial artery, brachial artery and ascending aorta. Blood pressure variability, defined as average beat-to-beat blood pressure difference, was calculated for systolic and diastolic blood pressure at each site. We observed a significant difference (p < .001) in systolic and diastolic blood pressure variability between the atrial fibrillation and sinus rhythm groups at all locations. Systolic blood pressure variability roughly doubled in the atrial fibrillation group compared to the sinus rhythm group (4.9 and 2.4 mmHg respectively). Diastolic beat-to-beat blood pressure variability was approximately 6 times as high in the atrial fibrillation group compared to the sinus rhythm group (7.5 and 1.2 mmHg respectively). No significant difference in blood pressure variability was seen between measurement locations. Beat-to-beat blood pressure variability in patients with atrial fibrillation was substantially higher than in patients with sinus rhythm. Hemodynamic effects of this beat-to-beat variation in blood pressure may negatively affect vascular structure and function, which may contribute to the increased cardiovascular morbidity and mortality seen in patients with atrial fibrillation.
Excito-oscillatory dynamics as a mechanism of ventricular fibrillation.
Gray, Richard A; Huelsing, Delilah J
2008-04-01
The instabilities associated with reentrant spiral waves are of paramount importance to the initiation and maintenance of tachyarrhythmias, especially ventricular fibrillation (VF). In addition to tissue heterogeneities, there are only a few basic purported mechanisms of spiral wave breakup, most notably restitution. We test the hypothesis that oscillatory membrane properties act to destabilize spiral waves. We recorded transmembrane potential (V(m)) from isolated rabbit myocytes using a constant current stimulation protocol. We developed a mathematical model that included both the stable excitable equilibrium point at resting V(m) (-80 mV) and the unstable oscillatory equilibrium point at elevated V(m) (-10 mV). Spiral wave dynamics were studied in 2-dimensional grids using variants of the model. All models showed restitution and reproduced the experimental values of transmembrane resistance at rest and during the action potential plateau. Stable spiral waves were observed when the model showed only 1 equilibrium point. However, spatio-temporal complexity was observed if the model showed both excitable and oscillatory equilibrium points (i.e., excito-oscillatory models). The initial wave breaks resulted from oscillatory waves expanding in all directions; after a few beats, the patterns were characterized by a combination of unstable spiral waves and target patterns consistent with the patterns observed on the heart surface during VF. In our model, this VF-like activity only occurred when the single cell period of V(m) oscillations was within a specific range. The VF-like patterns observed in our excito-oscillatory models could not be explained by the existing proposed instability mechanisms. Our results introduce the important suggestion that membrane dynamics responsible for V(m) oscillations at elevated V(m) levels can destabilize spiral waves and thus may be a novel therapeutic target for preventing VF.
Ohira, Suguru; Doi, Kiyoshi; Numata, Satoshi; Yamazaki, Sachiko; Itatani, Keiichi; Kawajiri, Hidetake; Morimoto, Kazuki; Yaku, Hitoshi
2017-10-01
To investigate the results of off-pump coronary artery grafting (OPCAB) with the proximal suture device (PSD) regarding postoperative stroke and graft patency. The PSD was used in 376 patients (32.0%), aorta-no-touch OPCAB was performed in 523 patients (45.2%), on-pump beating coronary artery bypass surgery (CABG) (on-beat group) in 125 patients (10.6%) including 51 conversions (conversion rate: 5.4%), and CABG with aortic clamp use (clamp group) in 152 patients. In the PSD group, Enclose II was used in 267 patients (71.0%). The hospital mortality rate was 1.95%. There was no early stroke in the OPCAB group, whereas the early-stroke rate was 0.8% in the on-beat group and 2.6% in the clamp group. The incidences of stroke at one month were: PSD group, 1.6%; no-touch group, 1.1%; on-beat group, 1.6%; and clamp group, 4.6% (p=0.014). The rates of complete revascularisation were higher in the PSD and clamp groups (94.7 and 94.0%, respectively) compared with the no-touch and on-beat groups (81.5 and 84.9%, respectively; p<0.001). The vein graft patency rates were comparable between the PSD and clamp groups. In multiple logistic regression analysis, OPCAB using the PSD did not increase the risk of stroke compared with the no-touch group (adjusted odds ratio [AOR]: 1.40; p=0.594) or on-beat group (AOR: 0.99; p=0.206), but reduced the risk of stroke compared with the clamp group (AOR: 0.19; p=0.005). Off-pump coronary artery grafting using the PSD was a safe and effective procedure. It led to lower incidences of postoperative stroke and excellent rates of graft patency and complete revascularisation compared with conventional CABG. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Individual Differences in Beat Perception Affect Gait Responses to Low- and High-Groove Music
Leow, Li-Ann; Parrott, Taylor; Grahn, Jessica A.
2014-01-01
Slowed gait in patients with Parkinson’s disease (PD) can be improved when patients synchronize footsteps to isochronous metronome cues, but limited retention of such improvements suggest that permanent cueing regimes are needed for long-term improvements. If so, music might make permanent cueing regimes more pleasant, improving adherence; however, music cueing requires patients to synchronize movements to the “beat,” which might be difficult for patients with PD who tend to show weak beat perception. One solution may be to use high-groove music, which has high beat salience that may facilitate synchronization, and affective properties, which may improve motivation to move. As a first step to understanding how beat perception affects gait in complex neurological disorders, we examined how beat perception ability affected gait in neurotypical adults. Synchronization performance and gait parameters were assessed as healthy young adults with strong or weak beat perception synchronized to low-groove music, high-groove music, and metronome cues. High-groove music was predicted to elicit better synchronization than low-groove music, due to its higher beat salience. Two musical tempi, or rates, were used: (1) preferred tempo: beat rate matched to preferred step rate and (2) faster tempo: beat rate adjusted to 22.5% faster than preferred step rate. For both strong and weak beat-perceivers, synchronization performance was best with metronome cues, followed by high-groove music, and worst with low-groove music. In addition, high-groove music elicited longer and faster steps than low-groove music, both at preferred tempo and at faster tempo. Low-groove music was particularly detrimental to gait in weak beat-perceivers, who showed slower and shorter steps compared to uncued walking. The findings show that individual differences in beat perception affect gait when synchronizing footsteps to music, and have implications for using music in gait rehabilitation. PMID:25374521
Detrended fluctuation analysis of non-stationary cardiac beat-to-beat interval of sick infants
NASA Astrophysics Data System (ADS)
Govindan, Rathinaswamy B.; Massaro, An N.; Al-Shargabi, Tareq; Niforatos Andescavage, Nickie; Chang, Taeun; Glass, Penny; du Plessis, Adre J.
2014-11-01
We performed detrended fluctuation analysis (DFA) of cardiac beat-to-beat intervals (RRis) collected from sick newborn infants over 1-4 day periods. We calculated four different metrics from the DFA fluctuation function: the DFA exponents αL (>40 beats up to one-fourth of the record length), αs (15-30 beats), root-mean-square (RMS) fluctuation on a short-time scale (20-50 beats), and RMS fluctuation on a long-time scale (110-150 beats). Except αL , all metrics clearly distinguished two groups of newborn infants (favourable vs. adverse) with well-characterized outcomes. However, the RMS fluctuations distinguished the two groups more consistently over time compared to αS . Furthermore, RMS distinguished the RRi of the two groups earlier compared to the DFA exponent. In all the three measures, the favourable outcome group displayed higher values, indicating a higher magnitude of (auto-)correlation and variability, thus normal physiology, compared to the adverse outcome group.
Ectopic beats in approximate entropy and sample entropy-based HRV assessment
NASA Astrophysics Data System (ADS)
Singh, Butta; Singh, Dilbag; Jaryal, A. K.; Deepak, K. K.
2012-05-01
Approximate entropy (ApEn) and sample entropy (SampEn) are the promising techniques for extracting complex characteristics of cardiovascular variability. Ectopic beats, originating from other than the normal site, are the artefacts contributing a serious limitation to heart rate variability (HRV) analysis. The approaches like deletion and interpolation are currently in use to eliminate the bias produced by ectopic beats. In this study, normal R-R interval time series of 10 healthy and 10 acute myocardial infarction (AMI) patients were analysed by inserting artificial ectopic beats. Then the effects of ectopic beats editing by deletion, degree-zero and degree-one interpolation on ApEn and SampEn have been assessed. Ectopic beats addition (even 2%) led to reduced complexity, resulting in decreased ApEn and SampEn of both healthy and AMI patient data. This reduction has been found to be dependent on level of ectopic beats. Editing of ectopic beats by interpolation degree-one method is found to be superior to other methods.
The effect of beat frequency on eye movements during free viewing.
Maróti, Emese; Knakker, Balázs; Vidnyánszky, Zoltán; Weiss, Béla
2017-02-01
External periodic stimuli entrain brain oscillations and affect perception and attention. It has been shown that background music can change oculomotor behavior and facilitate detection of visual objects occurring on the musical beat. However, whether musical beats in different tempi modulate information sampling differently during natural viewing remains to be explored. Here we addressed this question by investigating how listening to naturalistic drum grooves in two different tempi affects eye movements of participants viewing natural scenes on a computer screen. We found that the beat frequency of the drum grooves modulated the rate of eye movements: fixation durations were increased at the lower beat frequency (1.7Hz) as compared to the higher beat frequency (2.4Hz) and no music conditions. Correspondingly, estimated visual sampling frequency decreased as fixation durations increased with lower beat frequency. These results imply that slow musical beats can retard sampling of visual information during natural viewing by increasing fixation durations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Enhancement of cardiomyogenesis in stem cells by low intensity pulsed ultrasound
NASA Astrophysics Data System (ADS)
Teo, Ailing; Morshedi, Amir; Wang, Jen-Chieh; Lim, Mayasari; Zhou, Yufeng
2017-03-01
Low intensity pulsed ultrasound (LIPUS) has been shown to enhance bone and cartilage regeneration from stem cells. Gene expression of angiotensin II type 1 (AT1) receptor can be increased in LIPUS-treated osteoblasts. The AT1 receptor is a known mechanoreceptor in cardiomyocytes. It suggests that LIPUS may enhance cardiomyogenesis via mechanotransduction by increasing AT1 expression. Murine embryonic stem cells (ESCs) were treated daily by 10-min 1MHz LIPUS at spatial-average temporal-peak acoustic intensities of 30 mW/cm2 and 300 mW/cm2 in both continuous and pulsed wave (20% duty cycle) for 10 days. Polymerase chain reaction (PCR), immunocytochemistry, and beating rate were used to evaluate the cardiac viability quantitatively. After the treatment of LIPUS, beating rate of contractile areas and cardiac gene expression, such as α- and β-myosin heavy chain, were improved. Furthermore, no deleterious effects to the development of cardiac proteins were observed. All results suggest that LIPUS stimulation has the capacity of enhancing cardiomyogenesis from embryonic stem cells. With the benefit and the ease in incorporating LIPUS into various culture platforms, LIPUS has the potential to produce cardiomyocytes for clinical use in the future.
Heterodyne frequency measurements on N2O at 5.3 and 9.0 microns
NASA Technical Reports Server (NTRS)
Wells, J. S.; Jennings, D. A.; Hinz, A.; Murray, J. S.; Maki, A. G.
1985-01-01
Heterodyne frequency measurements on the 01(1)1-00(0)0 band of N2O have been made with the use of a tunable-diode laser, CO laser transfer oscillator, and a CO2 laser frequency synthesizer. A beat frequency was measured between a CO laser and tunable-diode laser whose frequency was locked to the peak of N2O absorption features. The frequency of the CO laser was simultaneously determined by neasuring the beat frequency with respect to a reference synthesized from two CO2 lasers. New rovibrational constants are given for the 01(1)1 state of N2O, which are in excellent agreement with previous results, although the band center is 4 MHz higher than in the previous measurements. A table for the line frequencies and their absolute uncertainties is given for the N2O absorption lines in the wave-number region from 1830 to 1920 kaysers. Some additional frequency measurements near the lower-frequency end of the 02(0)0-00(0)0 band have also been made with respect to a C-12)(0-18)2 laser.
Pneumatically-actuated artificial cilia array for biomimetic fluid propulsion.
Gorissen, Benjamin; de Volder, Michaël; Reynaerts, Dominiek
2015-11-21
Arrays of beating cilia emerged in nature as one of the most efficient propulsion mechanisms at a small scale, and are omnipresent in microorganisms. Previous attempts at mimicking these systems have foundered against the complexity of fabricating small-scale cilia exhibiting complex beating motions. In this paper, we propose for the first time arrays of pneumatically-actuated artificial cilia that are able to address some of these issues. These artificial cilia arrays consist of six highly flexible silicone rubber actuators with a diameter of 1 mm and a length of 8 mm that can be actuated independently from each other. In an experimental setup, the effects of the driving frequency, phase difference and duty cycle on the net flow in a closed-loop channel have been studied. Net fluid speeds of up to 19 mm s(-1) have been measured. Further, it is possible to invert the flow direction by simply changing the driving frequency or by changing the duty cycle of the driving block pulse pressure wave without changing the bending direction of the cilia. Using PIV measurements, we corroborate for the first time existing mathematical models of cilia arrays to measurements on prototypes.
Motion-gated acquisition for in vivo optical imaging
Gioux, Sylvain; Ashitate, Yoshitomo; Hutteman, Merlijn; Frangioni, John V.
2009-01-01
Wide-field continuous wave fluorescence imaging, fluorescence lifetime imaging, frequency domain photon migration, and spatially modulated imaging have the potential to provide quantitative measurements in vivo. However, most of these techniques have not yet been successfully translated to the clinic due to challenging environmental constraints. In many circumstances, cardiac and respiratory motion greatly impair image quality and∕or quantitative processing. To address this fundamental problem, we have developed a low-cost, field-programmable gate array–based, hardware-only gating device that delivers a phase-locked acquisition window of arbitrary delay and width that is derived from an unlimited number of pseudo-periodic and nonperiodic input signals. All device features can be controlled manually or via USB serial commands. The working range of the device spans the extremes of mouse electrocardiogram (1000 beats per minute) to human respiration (4 breaths per minute), with timing resolution ⩽0.06%, and jitter ⩽0.008%, of the input signal period. We demonstrate the performance of the gating device, including dramatic improvements in quantitative measurements, in vitro using a motion simulator and in vivo using near-infrared fluorescence angiography of beating pig heart. This gating device should help to enable the clinical translation of promising new optical imaging technologies. PMID:20059276
Mantovani, Giulia; Pifferi, Massimo; Vozzi, Giovanni
2010-06-01
Patients with primary ciliary dyskinesia (PCD) have structural and/or functional alterations of cilia that imply deficits in mucociliary clearance and different respiratory pathologies. A useful indicator for the difficult diagnosis is the ciliary beat frequency (CBF) that is significantly lower in pathological cases than in physiological ones. The CBF computation is not rapid, therefore, the aim of this study is to propose an automated method to evaluate it directly from videos of ciliated cells. The cells are taken from inferior nasal turbinates and videos of ciliary movements are registered and eventually processed by the developed software. The software consists in the extraction of features from videos (written with C++ language) and the computation of the frequency (written with Matlab language). This system was tested both on the samples of nasal cavity and software models, and the results were really promising because in a few seconds, it can compute a reliable frequency if compared with that measured with visual methods. It is to be noticed that the reliability of the computation increases with the quality of acquisition system and especially with the sampling frequency. It is concluded that the developed software could be a useful mean for PCD diagnosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakhtiari, S.; Liao, S.; Elmer, T.
This paper analyzes heart rate (HR) information from physiological tracings collected with a remote millimeter wave (mmW) I-Q sensor for biometric monitoring applications. A parameter optimization method based on the nonlinear Levenberg-Marquardt algorithm is used. The mmW sensor works at 94 GHz and can detect the vital signs of a human subject from a few to tens of meters away. The reflected mmW signal is typically affected by respiration, body movement, background noise, and electronic system noise. Processing of the mmW radar signal is, thus, necessary to obtain the true HR. The down-converted received signal in this case consists ofmore » both the real part (I-branch) and the imaginary part (Q-branch), which can be considered as the cosine and sine of the received phase of the HR signal. Instead of fitting the converted phase angle signal, the method directly fits the real and imaginary parts of the HR signal, which circumvents the need for phase unwrapping. This is particularly useful when the SNR is low. Also, the method identifies both beat-to-beat HR and individual heartbeat magnitude, which is valuable for some medical diagnosis applications. The mean HR here is compared to that obtained using the discrete Fourier transform.« less
Application of Cortical Processing Theory to Acoustical Analysis
2005-03-31
monaural/ binaural ). Initial results of these experiments show a gated/continuous difference analogous to the ’masking overshoot’ in tone detection. These... beat vee - bee zed - said neck - deck fence - pence Sibilatilon (S0) Graveness (GV) Compactness (CM) (Slbilated - Assibilated) (Grave - Acute) (Compact
Bell, Wade E.; Hallworth, Richard; Wyatt, Todd A.; Sisson, Joseph H.
2015-01-01
When Paramecium encounters positive stimuli, the membrane hyperpolarizes and ciliary beat frequency increases. We adapted an established immobilization protocol using a biological adhesive and a novel digital analysis system to quantify beat frequency in immobilized Paramecium. Cells showed low mortality and demonstrated beat frequencies consistent with previous studies. Chemoattractant molecules, reduction in external potassium, and posterior stimulation all increased somatic beat frequency. In all cases, the oral groove cilia maintained a higher beat frequency than mid-body cilia, but only oral cilia from cells stimulated with chemoattactants showed an increase from basal levels. PMID:25066640
Exploiting Concurrent Wake-Up Transmissions Using Beat Frequencies
2017-01-01
Wake-up receivers are the natural choice for wireless sensor networks because of their ultra-low power consumption and their ability to provide communications on demand. A downside of ultra-low power wake-up receivers is their low sensitivity caused by the passive demodulation of the carrier signal. In this article, we present a novel communication scheme by exploiting purposefully-interfering out-of-tune signals of two or more wireless sensor nodes, which produce the wake-up signal as the beat frequency of superposed carriers. Additionally, we introduce a communication algorithm and a flooding protocol based on this approach. Our experiments show that our approach increases the received signal strength up to 3 dB, improving communication robustness and reliability. Furthermore, we demonstrate the feasibility of our newly-developed protocols by means of an outdoor experiment and an indoor setup consisting of several nodes. The flooding algorithm achieves almost a 100% wake-up rate in less than 20 ms. PMID:28933749
Defects formation and spiral waves in a network of neurons in presence of electromagnetic induction.
Rostami, Zahra; Jafari, Sajad
2018-04-01
Complex anatomical and physiological structure of an excitable tissue (e.g., cardiac tissue) in the body can represent different electrical activities through normal or abnormal behavior. Abnormalities of the excitable tissue coming from different biological reasons can lead to formation of some defects. Such defects can cause some successive waves that may end up to some additional reorganizing beating behaviors like spiral waves or target waves. In this study, formation of defects and the resulting emitted waves in an excitable tissue are investigated. We have considered a square array network of neurons with nearest-neighbor connections to describe the excitable tissue. Fundamentally, electrophysiological properties of ion currents in the body are responsible for exhibition of electrical spatiotemporal patterns. More precisely, fluctuation of accumulated ions inside and outside of cell causes variable electrical and magnetic field. Considering undeniable mutual effects of electrical field and magnetic field, we have proposed the new Hindmarsh-Rose (HR) neuronal model for the local dynamics of each individual neuron in the network. In this new neuronal model, the influence of magnetic flow on membrane potential is defined. This improved model holds more bifurcation parameters. Moreover, the dynamical behavior of the tissue is investigated in different states of quiescent, spiking, bursting and even chaotic state. The resulting spatiotemporal patterns are represented and the time series of some sampled neurons are displayed, as well.
Collisional Processes Probed by using Resonant Four-Wave Mixing Spectroscopy
NASA Astrophysics Data System (ADS)
McCormack, E. F.; Stampanoni, A.; Hemmerling, B.
2000-06-01
Collisionally-induced decay processes in excited-state nitric oxide (NO) have been measured by using time-resolved two-color, resonant four-wave mixing (TC-RFWM) spectroscopy and polarization spectroscopy (PS). Markedly different time dependencies were observed in the data obtained by using TC-RFWM when compared to PS. Oscillations in the PS signal as a function of delay between the pump and probe laser pulses were observed and it was determined that their characteristics depend very sensitively on laser polarization. Analysis reveals that the oscillations in the decay curves are due to coherent excitation of unresolved hyperfine structure in the A state of NO. A comparison of beat frequencies obtained by taking Fourier transforms of the time data to the predicted hyperfine structure of the A state support this explanation. Further, based on a time-dependent model of PS as a FWM process, the signal’s dependence as a function of time on polarization configuration and excitation scheme can be predicted. By using the beat frequency values, fits of the model results to experimental decay curves for different pressures allows a study of the quenching rate in the A state due to collisional processes. A comparison of the PS data to laser-induced fluorescence decay measurements reveals different decay rates which suggests that the PS signal decay depends on the orientation and alignment of the excited molecules. The different behavior of the decay curves obtained by using TC-RFWM and PS can be understood in terms of the various contributions to the decay as described by the model and this has a direct bearing on which technique is preferable for a given set of experimental parameters.
Kenttä, Tuomas; Karsikas, Mari; Kiviniemi, Antti; Tulppo, Mikko; Seppänen, Tapio; Huikuri, Heikki V
2010-07-01
QRS/T angle and the cosine of the angle between QRS and T-wave vectors (TCRT), measured from standard 12-lead electrocardiogram (ECG), have been used in risk stratification of patients. This study assessed the possible rate dependence of these variables during exercise ECG in healthy subjects. Forty healthy volunteers, 20 men and 20 women, aged 34.6 +/- 3.4, underwent an exercise ECG testing. Twelve-lead ECG was recorded from each test subject and the spatial QRS/T angle and TCRT were automatically analyzed in a beat-to-beat manner with custom-made software. The individual TCRT/RR and QRST/RR patterns were fitted with seven different regression models, including a linear model and six nonlinear models. TCRT and QRS/T angle showed a significant rate dependence, with decreased values at higher heart rates (HR). In individual subjects, the second-degree polynomic model was the best regression model for TCRT/RR and QRST/RR slopes. It provided the best fit for both exercise and recovery. The overall TCRT/RR and QRST/RR slopes were similar between men and women during exercise and recovery. However, women had predominantly higher TCRT and QRS/T values. With respect to time, the dynamics of TCRT differed significantly between men and women; with a steeper exercise slope in women (women, -0.04/min vs -0.02/min in men, P < 0.0001). In addition, evident hysteresis was observed in the TCRT/RR slopes; with higher TCRT values during exercise. The individual patterns of TCRT and QRS/T angle are affected by HR and gender. Delayed rate adaptation creates hysteresis in the TCRT/RR slopes.
Hearing visuo-tactile synchrony - Sound-induced proprioceptive drift in the invisible hand illusion.
Darnai, Gergely; Szolcsányi, Tibor; Hegedüs, Gábor; Kincses, Péter; Kállai, János; Kovács, Márton; Simon, Eszter; Nagy, Zsófia; Janszky, József
2017-02-01
The rubber hand illusion (RHI) and its variant the invisible hand illusion (IHI) are useful for investigating multisensory aspects of bodily self-consciousness. Here, we explored whether auditory conditioning during an RHI could enhance the trisensory visuo-tactile-proprioceptive interaction underlying the IHI. Our paradigm comprised of an IHI session that was followed by an RHI session and another IHI session. The IHI sessions had two parts presented in counterbalanced order. One part was conducted in silence, whereas the other part was conducted on the backdrop of metronome beats that occurred in synchrony with the brush movements used for the induction of the illusion. In a first experiment, the RHI session also involved metronome beats and was aimed at creating an associative memory between the brush stroking of a rubber hand and the sounds. An analysis of IHI sessions showed that the participants' perceived hand position drifted more towards the body-midline in the metronome relative to the silent condition without any sound-related session differences. Thus, the sounds, but not the auditory RHI conditioning, influenced the IHI. In a second experiment, the RHI session was conducted without metronome beats. This confirmed the conditioning-independent presence of sound-induced proprioceptive drift in the IHI. Together, these findings show that the influence of visuo-tactile integration on proprioceptive updating is modifiable by irrelevant auditory cues merely through the temporal correspondence between the visuo-tactile and auditory events. © 2016 The British Psychological Society.
Sensorimotor Synchronization with Different Metrical Levels of Point-Light Dance Movements.
Su, Yi-Huang
2016-01-01
Rhythm perception and synchronization have been extensively investigated in the auditory domain, as they underlie means of human communication such as music and speech. Although recent studies suggest comparable mechanisms for synchronizing with periodically moving visual objects, the extent to which it applies to ecologically relevant information, such as the rhythm of complex biological motion, remains unknown. The present study addressed this issue by linking rhythm of music and dance in the framework of action-perception coupling. As a previous study showed that observers perceived multiple metrical periodicities in dance movements that embodied this structure, the present study examined whether sensorimotor synchronization (SMS) to dance movements resembles what is known of auditory SMS. Participants watched a point-light figure performing two basic steps of Swing dance cyclically, in which the trunk bounced at every beat and the limbs moved at every second beat, forming two metrical periodicities. Participants tapped synchronously to the bounce of the trunk with or without the limbs moving in the stimuli (Experiment 1), or tapped synchronously to the leg movements with or without the trunk bouncing simultaneously (Experiment 2). Results showed that, while synchronization with the bounce (lower-level pulse) was not influenced by the presence or absence of limb movements (metrical accent), synchronization with the legs (beat) was improved by the presence of the bounce (metrical subdivision) across different movement types. The latter finding parallels the "subdivision benefit" often demonstrated in auditory tasks, suggesting common sensorimotor mechanisms for visual rhythms in dance and auditory rhythms in music.
Maternal violence, victimization, and child physical punishment in Peru.
Gage, Anastasia J; Silvestre, Eva A
2010-07-01
This study examined whether mothers' experience of violence was a risk factor for physical punishment. Data were derived from the nationally representative 2000 Peru Demographic and Family Health Survey. Participants were 12,601 currently married women who were living with biological children aged 0-17 years and were responsible for disciplining the children. A multinomial logit model was used to determine the probabilities of using no physical punishment, slapping/spanking only, beating only, and both slapping/spanking and beating to discipline children. The study found that childhood history of physical punishment, a greater variety of intimate partner emotional violence and experience of intimate partner physical violence increased significantly a mother's probability of using physical punishment with her children, even after controlling for confounding factors. A mother's history of physical violence victimization by someone other than the current partner was also a significant factor for beating children as opposed to using non-physical forms of punishment. Mothers were at substantially increased risk of using physical punishment if they were victims of parental physical violence in childhood, intimate partner violence in the current union, and physical violence by someone other than the current partner. Increased public education is needed of the negative consequences of intimate partner emotional and physical violence victimization for mothers' childrearing strategies. There is a need to integrate intimate partner violence into child welfare programs and develop effective screening mechanisms for maternal violence victimization and child maltreatment. Copyright © 2010 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Starc, V.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M. A.; Delgado, R.
2007-01-01
We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.
NASA Technical Reports Server (NTRS)
DePalma, J. L.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; Starc, V.; Rahman, M. A.; Delgado, R.
2007-01-01
We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.
Estrogen replacement, vascular distensibility, and blood pressures in postmenopausal women.
De Meersman, R E; Zion, A S; Giardina, E G; Weir, J P; Lieberman, J S; Downey, J A
1998-05-01
The pathogenesis of blood pressure (BP) rise in aging women remains unexplained, and one of the many incriminating factors may include abnormalities in arteriolar resistance vessels. The aim of this study was to determine the effects of unopposed estrogen on arteriolar distensibility, baroreceptor sensitivity (BRS), BP changes, and rate-pressure product (RPP). We tested the hypotheses that estrogen replacement therapy (ERT) enhances arteriolar distensibility and ameliorates BRS, which leads to decreases in BP and RPP. Postmenopausal women participated in a single-blind crossover study; the participants of this study, after baseline measurements, were randomly assigned to receive estrogen (ERT) or a drug-free treatment with a 6-wk washout period between treatments. The single-blind design was instituted because subjects become unblinded due to physiological changes (i.e., fluid shifts, weight gain, and secretory changes) associated with estrogen intake. However, investigators and technicians involved in data collection and analyses remained blind. After each treatment, subjects performed identical autonomic tests, during which electrocardiograms, beat-by-beat BPs, and respiration were recorded. The area under the dicrotic notch of the BP wave was used as an index of arteriolar distensibility. The magnitude of the reflex bradycardia after a precipitous rise in BP was used to determine BRS. Power spectral analysis of heart rate variability was used to assess autonomic activity. BPs were recorded from resistance vessels in the finger using a beat-by-beat photoplethysmographic device. RPP, a noninvasive marker of myocardial oxygen consumption, was calculated. Repeated-measures analyses of variance revealed a significantly enhanced arteriolar distensibility and BRS after ERT (P < 0.05). A trend of a lower sympathovagal balance at rest was observed after ERT, however, this trend did not reach statistical significance (P = 0.061) compared with the other treatments. The above autonomic changes produced significantly lower systolic and diastolic BP changes and RPPs (P < 0.05) at rest and during isometric exercise. We conclude that short-term unopposed ERT favorably enhances arteriolar distensibility, BRS, and hemodynamic parameters in postmenopausal women. These findings have clinical implications in the goals for treating cardiovascular risk factors in aging women.
Context Specificity of the ANS Stress Response during Two Regrouping Experiments in Goats
Patt, Antonia; Gygax, Lorenz; Wechsler, Beat; Hillmann, Edna; Langbein, Jan; Keil, Nina M.
2016-01-01
The aim of this study was to analyze whether the activity of the autonomic nervous system (ANS) differs between two regrouping procedures in goats, which would indicate stimulus specificity of these stressors. Applying two regrouping procedures, we evaluated heart rate and heart rate variability (RMSSD, SDNN, and RMSSD/SDNN). The two regrouping procedures were (1) introduction of individual goats into established groups (“introduction experiment”) and (2) temporary separation and subsequent reintegration of individuals from/into their group with two levels of contact during separation (“separation experiment”). In the “introduction experiment,” the heart rate of introduced goats while lying decreased continuously from an average 78 to 68 beats/min from before the introduction to the last day of the introduction period. Inversely, RMSSD increased continuously from 41 to 62 ms, which, on its own, would indicate an adaptation to the situation. During the “separation experiment,” heart rate while lying was higher when goats were separated in the “acoustic contact treatment” (82 beats/min on average) compared with the “restricted physical contact treatment” (75 beats/min on average). This difference reflected a higher level of arousal during the “acoustic contact treatment.” However, heart rate activity did not allow detecting effects of separation or reintegration. Even though it can be assumed that both the separation and introduction of goats are stressful for goats, the ANS reactions observed in this study differed between the two management procedures indicating that the ANS activation was specific to each situation. In addition, we discuss the ANS results in context with earlier findings of variables of the hypothalamic pituitary adrenal (HPA) axis (fecal cortisol metabolites) and behavior (lying and feeding). As correspondence between ANS, HPA, and behavioral reactions was limited both within and across experiments, the results of this study underline the concept that stress response patterns are context specific. PMID:27551679
Multiple polarization states of vector soliton in fiber laser
NASA Astrophysics Data System (ADS)
Chen, Weicheng; Xu, Wencheng; Cao, Hui; Han, Dingan
2007-11-01
Vector soliton is obtained in erbium-doped fiber laser via nonlinear polarization rotation techniques. In experiment, we observe the every 4- and 7-pulse sinusoidal peak modulation. Temporal pulse sinusoidal peak modulation owes to evolution behavior of vector solitons in multiple polarization states. The polarizer in the laser modulates the mode-locked pulses with different polarization states into periodical pulse train intensities modulation. Moreover, the increasing pumping power lead to the appearance of the harmonic pulses and change the equivalent beat length to accelerate the polarization rotation. When the laser cavity length is the n-th multiple ratios to the beat length to maintain the mode-locking, the mode-locked vector soliton is in n-th multiple polarization states, exhibiting every n-pulse sinusoidal peak modulation.
The effect of binaural beats on verbal working memory and cortical connectivity.
Beauchene, Christine; Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A; Leonessa, Alexander
2017-04-01
Synchronization in activated regions of cortical networks affect the brain's frequency response, which has been associated with a wide range of states and abilities, including memory. A non-invasive method for manipulating cortical synchronization is binaural beats. Binaural beats take advantage of the brain's response to two pure tones, delivered independently to each ear, when those tones have a small frequency mismatch. The mismatch between the tones is interpreted as a beat frequency, which may act to synchronize cortical oscillations. Neural synchrony is particularly important for working memory processes, the system controlling online organization and retention of information for successful goal-directed behavior. Therefore, manipulation of synchrony via binaural beats provides a unique window into working memory and associated connectivity of cortical networks. In this study, we examined the effects of different acoustic stimulation conditions during an N-back working memory task, and we measured participant response accuracy and cortical network topology via EEG recordings. Six acoustic stimulation conditions were used: None, Pure Tone, Classical Music, 5 Hz binaural beats, 10 Hz binaural beats, and 15 Hz binaural beats. We determined that listening to 15 Hz binaural beats during an N-Back working memory task increased the individual participant's accuracy, modulated the cortical frequency response, and changed the cortical network connection strengths during the task. Only the 15 Hz binaural beats produced significant change in relative accuracy compared to the None condition. Listening to 15 Hz binaural beats during the N-back task activated salient frequency bands and produced networks characterized by higher information transfer as compared to other auditory stimulation conditions.
McConnell, Patrick A; Froeliger, Brett; Garland, Eric L; Ives, Jeffrey C; Sforzo, Gary A
2014-01-01
Binaural beats are an auditory illusion perceived when two or more pure tones of similar frequencies are presented dichotically through stereo headphones. Although this phenomenon is thought to facilitate state changes (e.g., relaxation), few empirical studies have reported on whether binaural beats produce changes in autonomic arousal. Therefore, the present study investigated the effects of binaural beating on autonomic dynamics [heart rate variability (HRV)] during post-exercise relaxation. Subjects (n = 21; 18-29 years old) participated in a double-blind, placebo-controlled study during which binaural beats and placebo were administered over two randomized and counterbalanced sessions (within-subjects repeated-measures design). At the onset of each visit, subjects exercised for 20-min; post-exercise, subjects listened to either binaural beats ('wide-band' theta-frequency binaural beats) or placebo (carrier tones) for 20-min while relaxing alone in a quiet, low-light environment. Dependent variables consisted of high-frequency (HF, reflecting parasympathetic activity), low-frequency (LF, reflecting sympathetic and parasympathetic activity), and LF/HF normalized powers, as well as self-reported relaxation. As compared to the placebo visit, the binaural-beat visit resulted in greater self-reported relaxation, increased parasympathetic activation and increased sympathetic withdrawal. By the end of the 20-min relaxation period there were no observable differences in HRV between binaural-beat and placebo visits, although binaural-beat associated HRV significantly predicted subsequent reported relaxation. Findings suggest that listening to binaural beats may exert an acute influence on both LF and HF components of HRV and may increase subjective feelings of relaxation.
Neural Entrainment to Auditory Imagery of Rhythms.
Okawa, Haruki; Suefusa, Kaori; Tanaka, Toshihisa
2017-01-01
A method of reconstructing perceived or imagined music by analyzing brain activity has not yet been established. As a first step toward developing such a method, we aimed to reconstruct the imagery of rhythm, which is one element of music. It has been reported that a periodic electroencephalogram (EEG) response is elicited while a human imagines a binary or ternary meter on a musical beat. However, it is not clear whether or not brain activity synchronizes with fully imagined beat and meter without auditory stimuli. To investigate neural entrainment to imagined rhythm during auditory imagery of beat and meter, we recorded EEG while nine participants (eight males and one female) imagined three types of rhythm without auditory stimuli but with visual timing, and then we analyzed the amplitude spectra of the EEG. We also recorded EEG while the participants only gazed at the visual timing as a control condition to confirm the visual effect. Furthermore, we derived features of the EEG using canonical correlation analysis (CCA) and conducted an experiment to individually classify the three types of imagined rhythm from the EEG. The results showed that classification accuracies exceeded the chance level in all participants. These results suggest that auditory imagery of meter elicits a periodic EEG response that changes at the imagined beat and meter frequency even in the fully imagined conditions. This study represents the first step toward the realization of a method for reconstructing the imagined music from brain activity.
Mechanism of reentry induction by a 9-V battery in rabbit ventricles
Burton, Rebecca A. B.; Kalla, Manish; Nanthakumar, Kumaraswamy; Plank, Gernot; Bub, Gil; Vigmond, Edward J.
2014-01-01
Although the application of a 9-V battery to the epicardial surface is a simple method of ventricular fibrillation induction, the fundamental mechanisms underlying this process remain unstudied. We used a combined experimental and modelling approach to understand how the interaction of direct current (DC) from a battery may induce reentrant activity within rabbit ventricles and its dependence on battery application timing and duration. A rabbit ventricular computational model was used to simulate 9-V battery stimulation for different durations at varying onset times during sinus rhythm. Corresponding high-resolution optical mapping measurements were conducted on rabbit hearts with DC stimuli applied via a relay system. DC application to diastolic tissue induced anodal and cathodal make excitations in both simulations and experiments. Subsequently, similar static epicardial virtual electrode patterns were formed that interacted with sinus beats but did not induce reentry. Upon battery release during diastole, break excitations caused single ectopics, similar to application, before sinus rhythm resumed. Reentry induction was possible for short battery applications when break excitations were slowed and forced to take convoluted pathways upon interaction with refractory tissue from prior make excitations or sinus beats. Short-lived reentrant activity could be induced for battery release shortly after a sinus beat for longer battery applications. In conclusion, the application of a 9-V battery to the epicardial surface induces reentry through a complex interaction of break excitations after battery release with prior induced make excitations or sinus beats. PMID:24464758
Mechanism of reentry induction by a 9-V battery in rabbit ventricles.
Bishop, Martin J; Burton, Rebecca A B; Kalla, Manish; Nanthakumar, Kumaraswamy; Plank, Gernot; Bub, Gil; Vigmond, Edward J
2014-04-01
Although the application of a 9-V battery to the epicardial surface is a simple method of ventricular fibrillation induction, the fundamental mechanisms underlying this process remain unstudied. We used a combined experimental and modelling approach to understand how the interaction of direct current (DC) from a battery may induce reentrant activity within rabbit ventricles and its dependence on battery application timing and duration. A rabbit ventricular computational model was used to simulate 9-V battery stimulation for different durations at varying onset times during sinus rhythm. Corresponding high-resolution optical mapping measurements were conducted on rabbit hearts with DC stimuli applied via a relay system. DC application to diastolic tissue induced anodal and cathodal make excitations in both simulations and experiments. Subsequently, similar static epicardial virtual electrode patterns were formed that interacted with sinus beats but did not induce reentry. Upon battery release during diastole, break excitations caused single ectopics, similar to application, before sinus rhythm resumed. Reentry induction was possible for short battery applications when break excitations were slowed and forced to take convoluted pathways upon interaction with refractory tissue from prior make excitations or sinus beats. Short-lived reentrant activity could be induced for battery release shortly after a sinus beat for longer battery applications. In conclusion, the application of a 9-V battery to the epicardial surface induces reentry through a complex interaction of break excitations after battery release with prior induced make excitations or sinus beats.
Beat Gestures Modulate Auditory Integration in Speech Perception
ERIC Educational Resources Information Center
Biau, Emmanuel; Soto-Faraco, Salvador
2013-01-01
Spontaneous beat gestures are an integral part of the paralinguistic context during face-to-face conversations. Here we investigated the time course of beat-speech integration in speech perception by measuring ERPs evoked by words pronounced with or without an accompanying beat gesture, while participants watched a spoken discourse. Words…
Laser Heterodyne Radiometer for Sensitive Detection of CO2 and CH4
NASA Technical Reports Server (NTRS)
Wilson, Emily L.; Miller, J. Houston
2011-01-01
We propose to develop an inexpensive, miniaturized, passive laser heterodyne radiometer (LHR) using commercially available telecommunications laser components to measure two significant carbon cycle gases in the atmospheric column: carbon dioxide (CO2) and methane (CH4). This instrument would operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach that supports the Decadal Survey. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In a laser heterodyne radiometer, the weak input signal is light that has undergone absorption by a trace gas. The local oscillator is a laser at a near-by frequency - in this case a low-cost distributed feedback (DFB) telecommunications laser. These two light waves are superimposed in either a beamsplitter or in a fiber coupler (as is the case in this design). The signals are mixed in the detector, and the RF beat frequency is extracted. Changes in concentration of the trace gas are realized through analyzing changes in the beat frequency amplitude. A schematic of the progression of the LHR development project is shown in the figure below. At the center (within the dashed line), light from the local oscillator is superimposed upon light that has undergone absorption by a trace gas, in a single mode fiber coupler. Superimposed light is mixed in a fast photoreceiver, and the beat signal is analyzed for changes in absorption. The left portion of the figure depicts a progression of light sources that pass through the trace gas, increasing in complexity in the downward direction. On the right side of the figure, RF signal processing progresses from a commercially available spectrum analyzer to a RF receiver, and finally to an RF filter bank to deconvolute portions of the beat frequency more heavily weighted for different altitudes.
Kashimura, Takeshi; Kodama, Makoto; Watanabe, Tohru; Tanaka, Komei; Hayashi, Yuka; Ohno, Yukako; Obata, Hiroaki; Ito, Masahiro; Hirono, Satoru; Hanawa, Haruo; Minamino, Tohru
2014-02-01
Mechanical alternans (MA) and electrical alternans (EA) are predictors of cardiac events. Experimental studies have suggested that refractoriness of calcium cycling underlies these cardiac alternans. However, refractoriness of left ventricular contraction has not been examined in patients with cardiac alternans. In 51 patients with miscellaneous heart diseases, incremental right atrial pacing was performed to induce MA and EA. MA was quantified by alternans amplitude (AA: the difference between left ventricular dP/dt of a strong beat and that of a weak beat), and AA at 100/min (AA100) and maximal AA (AAmax) were measured. EA was defined as alternation of T wave morphology in 12-lead electrocardiogram. Relative refractoriness of left ventricular contraction was examined by drawing the mechanical restitution curve under a basal coupling interval (BCL) of 600 ms (100/min) and was assessed by the slope at BCL (Δmechanical restitution). Postextrasystolic potentiation (PESP) was also examined and the slope of PESP curve (ΔPESP) was assessed as a property to alternate strong and weak beats. MA and EA were induced in 19 patients and in none at 100/min or less, and at any heart rate in 32 and in 10, respectively. AA100 and AAmax correlated positively with Δmechanical restitution and negatively with ΔPESP. Patients with EA had a significantly larger Δmechanical restitution and a significantly larger absolute value of ΔPESP than those without. In patients with MA and EA, the left ventricular contractile force during tachycardia is under relative refractoriness and prone to cause large fluctuation of contractile force. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.
Explaining Polarization Reversals in STEREO Wave Data
NASA Technical Reports Server (NTRS)
Breneman, A.; Cattell, C.; Wygant, J.; Kersten, K.; Wilson, L, B., III; Dai, L.; Colpitts, C.; Kellogg, P. J.; Goetz, K.; Paradise, A.
2012-01-01
Recently Breneman et al. reported observations of large amplitude lightning and transmitter whistler mode waves from two STEREO passes through the inner radiation belt (L<2). Hodograms of the electric field in the plane transverse to the magnetic field showed that the transmitter waves underwent periodic polarization reversals. Specifically, their polarization would cycle through a pattern of right-hand to linear to left-hand polarization at a rate of roughly 200 Hz. The lightning whistlers were observed to be left-hand polarized at frequencies greater than the lower hybrid frequency and less than the transmitter frequency (21.4 kHz) and right-hand polarized otherwise. Only righthand polarized waves in the inner radiation belt should exist in the frequency range of the whistler mode and these reversals were not explained in the previous paper. We show, with a combination of observations and simulated wave superposition, that these polarization reversals are due to the beating of an incident electromagnetic whistler mode wave at 21.4 kHz and linearly polarized, symmetric lower hybrid sidebands Doppler-shifted from the incident wave by +/-200 Hz. The existence of the lower hybrid waves is consistent with the parametric decay mechanism of Lee and Kuo whereby an incident whistler mode wave decays into symmetric, short wavelength lower hybrid waves and a purely growing (zero-frequency) mode. Like the lower hybrid waves, the purely growing mode is Doppler-shifted by 200 Hz as observed on STEREO. This decay mechanism in the upper ionosphere has been previously reported at equatorial latitudes and is thought to have a direct connection with explosive spread F enhancements. As such it may represent another dissipation mechanism of VLF wave energy in the ionosphere and may help to explain a deficit of observed lightning and transmitter energy in the inner radiation belts as reported by Starks et al.
Ultrasound Imaging in Teaching Cardiac Physiology
ERIC Educational Resources Information Center
Johnson, Christopher D.; Montgomery, Laura E. A.; Quinn, Joe G.; Roe, Sean M.; Stewart, Michael T.; Tansey, Etain A.
2016-01-01
This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such…
Read with a Beat: Developing Literacy through Music and Song (Teaching Reading).
ERIC Educational Resources Information Center
Kolb, Gayla R.
1996-01-01
Argues that the singing-reading connective helps children learn to read and fosters a love for reading. Discusses integrating music with reading and notes various activities designed to extend the singing-reading experience, involving book concepts, sight vocabulary, reading comprehension, and fluency. (SR)
USDA-ARS?s Scientific Manuscript database
Molecular gut-content analysis enables detection of arthropod predation with minimal disruption of ecosystem processes. Field and laboratory experiments have demonstrated that mass-collection methods, such as sweep-netting, vacuum sampling, and foliage beating, can lead to contamination of fed pred...
USDA-ARS?s Scientific Manuscript database
Molecular gut-content analysis enables detection of arthropod predation with minimal disruption of ecosystem processes. Field and laboratory experiments have demonstrated that mass-collection methods, such as sweep-netting, vacuum sampling, and foliage beating, can lead to contamination of fed pred...
EDITORIAL: Laser and plasma accelerators Laser and plasma accelerators
NASA Astrophysics Data System (ADS)
Bingham, Robert
2009-02-01
This special issue on laser and plasma accelerators illustrates the rapid advancement and diverse applications of laser and plasma accelerators. Plasma is an attractive medium for particle acceleration because of the high electric field it can sustain, with studies of acceleration processes remaining one of the most important areas of research in both laboratory and astrophysical plasmas. The rapid advance in laser and accelerator technology has led to the development of terawatt and petawatt laser systems with ultra-high intensities and short sub-picosecond pulses, which are used to generate wakefields in plasma. Recent successes include the demonstration by several groups in 2004 of quasi-monoenergetic electron beams by wakefields in the bubble regime with the GeV energy barrier being reached in 2006, and the energy doubling of the SLAC high-energy electron beam from 42 to 85 GeV. The electron beams generated by the laser plasma driven wakefields have good spatial quality with energies ranging from MeV to GeV. A unique feature is that they are ultra-short bunches with simulations showing that they can be as short as a few femtoseconds with low-energy spread, making these beams ideal for a variety of applications ranging from novel high-brightness radiation sources for medicine, material science and ultrafast time-resolved radiobiology or chemistry. Laser driven ion acceleration experiments have also made significant advances over the last few years with applications in laser fusion, nuclear physics and medicine. Attention is focused on the possibility of producing quasi-mono-energetic ions with energies ranging from hundreds of MeV to GeV per nucleon. New acceleration mechanisms are being studied, including ion acceleration from ultra-thin foils and direct laser acceleration. The application of wakefields or beat waves in other areas of science such as astrophysics and particle physics is beginning to take off, such as the study of cosmic accelerators considered by Chen et al where the driver, instead of being a laser, is a whistler wave known as the magnetowave plasma accelerator. The application to electron--positron plasmas that are found around pulsars is studied in the paper by Shukla, and to muon acceleration by Peano et al. Electron wakefield experiments are now concentrating on control and optimisation of high-quality beams that can be used as drivers for novel radiation sources. Studies by Thomas et al show that filamentation has a deleterious effect on the production of high quality mono-energetic electron beams and is caused by non-optimal choice of focusing geometry and/or electron density. It is crucial to match the focusing with the right plasma parameters and new types of plasma channels are being developed, such as the magnetically controlled plasma waveguide reported by Froula et al. The magnetic field provides a pressure profile shaping the channel to match the guiding conditions of the incident laser, resulting in predicted electron energies of 3GeV. In the forced laser-wakefield experiment Fang et al show that pump depletion reduces or inhibits the acceleration of electrons. One of the earlier laser acceleration concepts known as the beat wave may be revived due to the work by Kalmykov et al who report on all-optical control of nonlinear focusing of laser beams, allowing for stable propagation over several Rayleigh lengths with pre-injected electrons accelerated beyond 100 MeV. With the increasing number of petawatt lasers, attention is being focused on different acceleration regimes such as stochastic acceleration by counterpropagating laser pulses, the relativistic mirror, or the snow-plough effect leading to single-step acceleration reported by Mendonca. During wakefield acceleration the leading edge of the pulse undergoes frequency downshifting and head erosion as the laser energy is transferred to the wake while the trailing edge of the laser pulse undergoes frequency up-shift. This is commonly known as photon deceleration and acceleration and is the result of a modulational instability. Simulations reported by Trines et al using a photon-in-cell code or wave kinetic code agree extremely well with experimental observation. Ion acceleration is actively studied; for example the papers by Robinson, Macchi, Marita and Tripathi all discuss different types of acceleration mechanisms from direct laser acceleration, Coulombic explosion and double layers. Ion acceleration is an exciting development that may have great promise in oncology. The surprising application is in muon acceleration, demonstrated by Peano et al who show that counterpropagating laser beams with variable frequencies drive a beat structure with variable phase velocity, leading to particle trapping and acceleration with possible application to a future muon collider and neutrino factory. Laser and plasma accelerators remain one of the exciting areas of plasma physics with applications in many areas of science ranging from laser fusion, novel high-brightness radiation sources, particle physics and medicine. The guest editor would like to thank all authors and referees for their invaluable contributions to this special issue.
Grose, John H.; Buss, Emily; Hall, Joseph W.
2012-01-01
Previous studies of binaural beats have noted individual variability and response lability, but little attention has been paid to the salience of the binaural beat percept. The purpose of this study was to gauge the strength of the binaural beat percept by matching its salience to that of sinusoidal amplitude modulation (SAM), and to then compare rate discrimination for the two types of fluctuation. Rate discrimination was measured for standard rates of 4, 8, 16, and 32 Hz – all in the 500-Hz carrier region. Twelve normal-hearing adults participated in this study. The results indicated that discrimination acuity for binaural beats is similar to that for SAM tones whose depths of modulation have been adjusted to provide equivalent modulation salience. The matched-salience SAM tones had relatively shallow depths of modulation, suggesting that the perceptual strength of binaural beats is relatively weak, although all listeners perceived them. The Weber fraction for detection of an increase in binaural beat rate is roughly constant across beat rates, at least for rates above 4 Hz, as is rate discrimination for SAM tones. PMID:22326292
Grose, John H; Buss, Emily; Hall, Joseph W
2012-03-01
Previous studies of binaural beats have noted individual variability and response lability, but little attention has been paid to the salience of the binaural beat percept. The purpose of this study was to gauge the strength of the binaural beat percept by matching its salience to that of sinusoidal amplitude modulation (SAM), and to then compare rate discrimination for the two types of fluctuation. Rate discrimination was measured for standard rates of 4, 8, 16, and 32 Hz - all in the 500-Hz carrier region. Twelve normal-hearing adults participated in this study. The results indicated that discrimination acuity for binaural beats is similar to that for SAM tones whose depths of modulation have been adjusted to provide equivalent modulation salience. The matched-salience SAM tones had relatively shallow depths of modulation, suggesting that the perceptual strength of binaural beats is relatively weak, although all listeners perceived them. The Weber fraction for detection of an increase in binaural beat rate is roughly constant across beat rates, at least for rates above 4 Hz, as is rate discrimination for SAM tones. Copyright © 2012 Elsevier B.V. All rights reserved.
Nozaradan, Sylvie; Zerouali, Younes; Peretz, Isabelle; Mouraux, André
2015-03-01
Synchronizing movements with rhythmic inputs requires tight coupling of sensory and motor neural processes. Here, using a novel approach based on the recording of steady-state-evoked potentials (SS-EPs), we examine how distant brain areas supporting these processes coordinate their dynamics. The electroencephalogram was recorded while subjects listened to a 2.4-Hz auditory beat and tapped their hand on every second beat. When subjects tapped to the beat, the EEG was characterized by a 2.4-Hz SS-EP compatible with beat-related entrainment and a 1.2-Hz SS-EP compatible with movement-related entrainment, based on the results of source analysis. Most importantly, when compared with passive listening of the beat, we found evidence suggesting an interaction between sensory- and motor-related activities when subjects tapped to the beat, in the form of (1) additional SS-EP appearing at 3.6 Hz, compatible with a nonlinear product of sensorimotor integration; (2) phase coupling of beat- and movement-related activities; and (3) selective enhancement of beat-related activities over the hemisphere contralateral to the tapping, suggesting a top-down effect of movement-related activities on auditory beat processing. Taken together, our results are compatible with the view that rhythmic sensorimotor synchronization is supported by a dynamic coupling of sensory and motor related activities. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Normand, Hervé; Lemarchand, Erick; Arbeille, Philippe; Quarck, Gaëlle; Vaïda, Pierre; Duretete, Arnaud; Denise, Pierre
2007-12-01
Accurate measurement of beat-to-beat arterial blood pressure is essential for understanding the cardiovascular adaptation to weightlessness; however, the intra-arterial standard of beat-to-beat blood pressure measurement has never been used during space flight because of its invasive nature. The aim of the present study was to compare noninvasive radial artery tonometry blood pressure measurement with intra-radial pressure measurement during microgravity and hypergravity generated by parabolic flights. Two study participants, equipped with an intra-radial pressure line on the left arm and a Colin CBM-7000 (Colin Corp., Komaki City, Japan) beat-to-beat pressure measurement apparatus on the right arm, were studied in a supine position, during parabolic flights on board of the Airbus A300 OG of the Centre National d'Etudes Spatiales. The mean and standard deviations of the beat-to-beat difference between tonometric and intra-radial blood pressure were calculated for systolic and diastolic arterial pressure in the three gravity conditions (1g, 0 g and 1.8 g) experienced during parabolic flight. The Colin CBM-7000 met the specifications required by the Association for the Advancement of Medical Instrumentation in the 0 g environment. Gravity, however, significantly affected the difference between tonometric and intra-arterial blood pressure, possibly owing to the effect of gravity on the apparent weight of the device and the corresponding calibration factor. We conclude that the Colin CBM-7000 can be used with confidence during space flight.
Binaural auditory beats affect vigilance performance and mood.
Lane, J D; Kasian, S J; Owens, J E; Marsh, G R
1998-01-01
When two tones of slightly different frequency are presented separately to the left and right ears the listener perceives a single tone that varies in amplitude at a frequency equal to the frequency difference between the two tones, a perceptual phenomenon known as the binaural auditory beat. Anecdotal reports suggest that binaural auditory beats within the electroencephalograph frequency range can entrain EEG activity and may affect states of consciousness, although few scientific studies have been published. This study compared the effects of binaural auditory beats in the EEG beta and EEG theta/delta frequency ranges on mood and on performance of a vigilance task to investigate their effects on subjective and objective measures of arousal. Participants (n = 29) performed a 30-min visual vigilance task on three different days while listening to pink noise containing simple tones or binaural beats either in the beta range (16 and 24 Hz) or the theta/delta range (1.5 and 4 Hz). However, participants were kept blind to the presence of binaural beats to control expectation effects. Presentation of beta-frequency binaural beats yielded more correct target detections and fewer false alarms than presentation of theta/delta frequency binaural beats. In addition, the beta-frequency beats were associated with less negative mood. Results suggest that the presentation of binaural auditory beats can affect psychomotor performance and mood. This technology may have applications for the control of attention and arousal and the enhancement of human performance.
Enhanced timing abilities in percussionists generalize to rhythms without a musical beat.
Cameron, Daniel J; Grahn, Jessica A
2014-01-01
The ability to entrain movements to music is arguably universal, but it is unclear how specialized training may influence this. Previous research suggests that percussionists have superior temporal precision in perception and production tasks. Such superiority may be limited to temporal sequences that resemble real music or, alternatively, may generalize to musically implausible sequences. To test this, percussionists and nonpercussionists completed two tasks that used rhythmic sequences varying in musical plausibility. In the beat tapping task, participants tapped with the beat of a rhythmic sequence over 3 stages: finding the beat (as an initial sequence played), continuation of the beat (as a second sequence was introduced and played simultaneously), and switching to a second beat (the initial sequence finished, leaving only the second). The meters of the two sequences were either congruent or incongruent, as were their tempi (minimum inter-onset intervals). In the rhythm reproduction task, participants reproduced rhythms of four types, ranging from high to low musical plausibility: Metric simple rhythms induced a strong sense of the beat, metric complex rhythms induced a weaker sense of the beat, nonmetric rhythms had no beat, and jittered nonmetric rhythms also had no beat as well as low temporal predictability. For both tasks, percussionists performed more accurately than nonpercussionists. In addition, both groups were better with musically plausible than implausible conditions. Overall, the percussionists' superior abilities to entrain to, and reproduce, rhythms generalized to musically implausible sequences.
McConnell, Patrick A.; Froeliger, Brett; Garland, Eric L.; Ives, Jeffrey C.; Sforzo, Gary A.
2014-01-01
Binaural beats are an auditory illusion perceived when two or more pure tones of similar frequencies are presented dichotically through stereo headphones. Although this phenomenon is thought to facilitate state changes (e.g., relaxation), few empirical studies have reported on whether binaural beats produce changes in autonomic arousal. Therefore, the present study investigated the effects of binaural beating on autonomic dynamics [heart rate variability (HRV)] during post-exercise relaxation. Subjects (n = 21; 18–29 years old) participated in a double-blind, placebo-controlled study during which binaural beats and placebo were administered over two randomized and counterbalanced sessions (within-subjects repeated-measures design). At the onset of each visit, subjects exercised for 20-min; post-exercise, subjects listened to either binaural beats (‘wide-band’ theta-frequency binaural beats) or placebo (carrier tones) for 20-min while relaxing alone in a quiet, low-light environment. Dependent variables consisted of high-frequency (HF, reflecting parasympathetic activity), low-frequency (LF, reflecting sympathetic and parasympathetic activity), and LF/HF normalized powers, as well as self-reported relaxation. As compared to the placebo visit, the binaural-beat visit resulted in greater self-reported relaxation, increased parasympathetic activation and increased sympathetic withdrawal. By the end of the 20-min relaxation period there were no observable differences in HRV between binaural-beat and placebo visits, although binaural-beat associated HRV significantly predicted subsequent reported relaxation. Findings suggest that listening to binaural beats may exert an acute influence on both LF and HF components of HRV and may increase subjective feelings of relaxation. PMID:25452734
The effect of binaural beats on verbal working memory and cortical connectivity
NASA Astrophysics Data System (ADS)
Beauchene, Christine; Abaid, Nicole; Moran, Rosalyn; Diana, Rachel A.; Leonessa, Alexander
2017-04-01
Objective. Synchronization in activated regions of cortical networks affect the brain’s frequency response, which has been associated with a wide range of states and abilities, including memory. A non-invasive method for manipulating cortical synchronization is binaural beats. Binaural beats take advantage of the brain’s response to two pure tones, delivered independently to each ear, when those tones have a small frequency mismatch. The mismatch between the tones is interpreted as a beat frequency, which may act to synchronize cortical oscillations. Neural synchrony is particularly important for working memory processes, the system controlling online organization and retention of information for successful goal-directed behavior. Therefore, manipulation of synchrony via binaural beats provides a unique window into working memory and associated connectivity of cortical networks. Approach. In this study, we examined the effects of different acoustic stimulation conditions during an N-back working memory task, and we measured participant response accuracy and cortical network topology via EEG recordings. Six acoustic stimulation conditions were used: None, Pure Tone, Classical Music, 5 Hz binaural beats, 10 Hz binaural beats, and 15 Hz binaural beats. Main results. We determined that listening to 15 Hz binaural beats during an N-Back working memory task increased the individual participant’s accuracy, modulated the cortical frequency response, and changed the cortical network connection strengths during the task. Only the 15 Hz binaural beats produced significant change in relative accuracy compared to the None condition. Significance. Listening to 15 Hz binaural beats during the N-back task activated salient frequency bands and produced networks characterized by higher information transfer as compared to other auditory stimulation conditions.
Multifrequency Raman amplifiers
NASA Astrophysics Data System (ADS)
Barth, Ido; Fisch, Nathaniel J.
2018-03-01
In its usual implementation, the Raman amplifier features only one pump carrier frequency. However, pulses with well-separated frequencies can also be Raman amplified while compressed in time. Amplification with frequency-separated pumps is shown to hold even in the highly nonlinear, pump-depletion regime, as derived through a fluid model, and demonstrated via particle-in-cell simulations. The resulting efficiency is similar to single-frequency amplifiers, but, due to the beat-wave waveform of both the pump lasers and the amplified seed pulses, these amplifiers feature higher seed intensities with a shorter spike duration. Advantageously, these amplifiers also suffer less noise backscattering, because the total fluence is split between the different spectral components.
High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia
NASA Technical Reports Server (NTRS)
Zupet, Petra; Finderle, Zarko; Schlegel, Todd T.; Princi, Tanja; Starc, Vito
2010-01-01
High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.
NASA Astrophysics Data System (ADS)
Bingham, R.; De Angelis, U.; Shukla, P. K.; Stenflo, L.
1990-01-01
During the last decade considerable progress has been made in the area of nonlinear plasma wave phenomena and their applications. In order to exhibit the present state-of-art in this field, a one-week (22-26 May) workshop on Large Amplitude Waves and Fields was organized at the International Centre for Theoretical Physics (ICTP), Trieste, Italy, during the bi-yearly activity of the Spring College on Plasma Physics (15 May-9 June, 1989). Most of the invited lectures are published in this Topical Issue of Physica Scripta so that scientists working, or who want to enter the field of nonlinear plasma wave theory, can find out what has been achieved and what are the current research trends in this area. The material included here consists of general plasma wave theory, results of computer simulations, and experimental verifications. Without going into any detail, we shall just highlight the topics and the general features of the lectures contained in these proceedings. Various aspects of the excitation, propagation and interaction of nonlinear waves in plasmas are reviewed. Their relevance to plasma-based beat wave accelerators, short pulse laser and particle beam wake-field accelerators, plasma lenses, laser fusion and ionospheric modification experiments is discussed. Some introductory lectures present the general physics of nonlinear plasma waves including the saturation mechanisms and wave breaking conditions for both non-relativistic and relativistic nonlinearities. Three wave and four wave processes which include stimulated Raman, Brillouin and Compton scattering, modulational instabilities, self-focusing and collapse of the waves are discussed, emphasizing the important effects due to the relativistic electron mass variation and ponderomotive force. Detailed numerical studies of the interaction of high frequency plasma waves with low frequency density fluctuations described by the Zakharov equations show the localization of the high frequency field in density cavities and their burn-out resulting in very strong turbulence. Remarkable agreement between the simulations and ionospheric modification experiments have been demonstrated. The articles presented also attempted to correlate the theories of parametric instabilities with experimental observations. The properties of plasma lenses used for focusing of high energy particle beams is also presented as part of the uses of the nonlinear plasmas. Self-organisation of plasmas resulting in coherent nonlinear structures and particle diffusion processes are reported. On the experimental side the nonlinear optics of plasmas as a new area of research has been reviewed. This is becoming an important area for research since it treats the plasma from the outset as a nonlinear medium. Experimental observations of phase conjugation of electromagnetic signals demonstrate once again the importance of the nonlinearities inherent in the interaction of large amplitude waves with plasmas. Finally the importance of turbulence in space plasmas is emphasized in a discussion of the auroral phenomenon, presenting the plasma physicists point of view on this topic. The workshop, attended by scientists from all over the world, stimulated a great deal of lively discussions about the theoretical foundations, experimental observations and interpretations together with computer simulation results on the physics of nonlinear plasma wave phenomena. The workshop was made possible by the kind support of Professors A Salam, L Bertocchi and M Hassan. We are grateful to them for giving us the opportunity to organize the workshop within the activities of the Spring College on Plasma Physics. Thanks are also due to the ICTP and the European Economic Community (EEC) for providing partial financial support. Finally, our most cordial thanks are extended to the invited speakers for coming to Trieste delivering excellent talks and enhancing the activity of the Spring College.