Laboratory or field tests for evaluating firefighters' work capacity?
Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer
2014-01-01
Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = -0.81) and barbell shoulder press (rs = -0.77), for Pulling: IE shoulder extension (rs = -0.82) and bench press (rs = -0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = -0.83) and bench press (rs = -0.82), and for the Terrain work task: IE trunk flexion (rs = -0.58) and upright barbell row (rs = -0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.
Dexterity and Bench Assembly Work Productivity in Adults with Mild Mental Retardation.
ERIC Educational Resources Information Center
Serr, Russell; And Others
1994-01-01
This study compared dexterity scores using the Vocational Transit Test System and bench assembly work productivity in 30 adults with mild mental retardation. Moderately high correlations were found between work output and motor coordination, manual dexterity, finger dexterity (with and without assembly), and total dexterity score. Finger dexterity…
ETR, TRA642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, ...
ETR, TRA-642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, CRANE WORKING AREAS. PHILLIPS PETROLEUM COMPANY ETR-D-1584, 5/1959. INL INDEX NO. 532-0642-00-706-020323, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?
Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer
2014-01-01
Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs = −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity. PMID:24614596
NASA Astrophysics Data System (ADS)
Maniowski, M.; Para, S.; Knapczyk, M.
2016-09-01
This paper presents a modernization approach of a standard test bench for determination of damping characteristics of automotive shock absorbers. It is known that the real-life work conditions of wheel-suspension dampers are not easy to reproduce in laboratory conditions, for example considering a high frequency damper response or a noise emission. The proposed test bench consists of many elements from a real vehicle suspension. Namely, an original tyre-wheel with additional unsprung mass, a suspension spring, an elastic top mount, damper bushings and a simplified wheel guiding mechanism. Each component was tested separately in order to identify its mechanical characteristics. The measured data serve as input parameters for a numerical simulation of the test bench behaviour by using a vibratory model with 3 degrees of freedom. Study on the simulation results and the measurements are needed for further development of the proposed test bench.
Tests of the Daimler D-IVa Engine at a High Altitude Test Bench
NASA Technical Reports Server (NTRS)
Noack, W G
1920-01-01
Reports of tests of a Daimler IVa engine at the test-bench at Friedrichshafen, show that the decrease of power of that engine, at high altitudes, was established, and that the manner of its working when air is supplied at a certain pressure was explained. These tests were preparatory to the installation of compressors in giant aircraft for the purpose of maintaining constant power at high altitudes.
Castillo Aguilar, Juan Jesús; Cabrera Carrillo, Juan Antonio; Guerra Fernández, Antonio Jesús; Postigo Pozo, Sergio
2017-01-01
Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR) of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures. PMID:28353674
Castillo Aguilar, Juan Jesús; Cabrera Carrillo, Juan Antonio; Guerra Fernández, Antonio Jesús; Postigo Pozo, Sergio
2017-03-29
Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR) of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures.
Test bench for measurements of NOvA scintillator properties at JINR
NASA Astrophysics Data System (ADS)
Velikanova, D. S.; Antoshkin, A. I.; Anfimov, N. V.; Samoylov, O. B.
2018-04-01
The NOvA experiment was built to study oscillation parameters, mass hierarchy, CP- violation phase in the lepton sector and θ23 octant, via vɛ appearance and vμ disappearance modes in both neutrino and antineutrino beams. These scientific goals require good knowledge about NOvA scintillator basic properties. The new test bench was constructed and upgraded at JINR. The main goal of this bench is to measure scintillator properties (for solid and liquid scintillators), namely α/β discrimination and Birk's coefficients for protons and other hadrons (quenching factors). This knowledge will be crucial for recovering the energy of the hadronic part of neutrino interactions with scintillator nuclei. α/β discrimination was performed on the first version of the bench for LAB-based and NOvA scintillators. It was performed again on the upgraded version of the bench with higher statistic and precision level. Preliminary result of quenching factors for protons was obtained. A technical description of both versions of the bench and current results of the measurements and analysis are presented in this work.
Test-bench system for a borehole azimuthal acoustic reflection imaging logging tool
NASA Astrophysics Data System (ADS)
Liu, Xianping; Ju, Xiaodong; Qiao, Wenxiao; Lu, Junqiang; Men, Baiyong; Liu, Dong
2016-06-01
The borehole azimuthal acoustic reflection imaging logging tool (BAAR) is a new generation of imaging logging tool, which is able to investigate stratums in a relatively larger range of space around the borehole. The BAAR is designed based on the idea of modularization with a very complex structure, so it has become urgent for us to develop a dedicated test-bench system to debug each module of the BAAR. With the help of a test-bench system introduced in this paper, test and calibration of BAAR can be easily achieved. The test-bench system is designed based on the client/server model. The hardware system mainly consists of a host computer, an embedded controlling board, a bus interface board, a data acquisition board and a telemetry communication board. The host computer serves as the human machine interface and processes the uploaded data. The software running on the host computer is designed based on VC++. The embedded controlling board uses Advanced Reduced Instruction Set Machines 7 (ARM7) as the micro controller and communicates with the host computer via Ethernet. The software for the embedded controlling board is developed based on the operating system uClinux. The bus interface board, data acquisition board and telemetry communication board are designed based on a field programmable gate array (FPGA) and provide test interfaces for the logging tool. To examine the feasibility of the test-bench system, it was set up to perform a test on BAAR. By analyzing the test results, an unqualified channel of the electronic receiving cabin was discovered. It is suggested that the test-bench system can be used to quickly determine the working condition of sub modules of BAAR and it is of great significance in improving production efficiency and accelerating industrial production of the logging tool.
Testing of a work bench for handling of explosives in the laboratory
NASA Astrophysics Data System (ADS)
Hank, R.; Johansson, K.; Lagman, L.
1981-01-01
A prototype work station was developed at which jobs can be carried out with explosives up to 10 gr and deflagrating products up to 50 gr. Tests were made to investigate the consequences of a spontaneous accident during work. Conclusions are: the workbench offers good protection against splinters provided the inside walls are coated with a shock absorber; the carbonate glass should be a minimum of eight mm thick; the risk of burns, except on arms and hands, is very low; the bench withstands the explosion with the given weight of explosives (10 gr); the risk of lesions on the lung are very low, for the operator as well as for somebody nearby.
Dawson, Brian; Vladich, Todd; Blanksby, Brian A
2002-11-01
To determine whether 4 weeks of oral creatine (Cr) supplementation could enhance single freestyle sprint and swim bench performance in experienced competitive junior swimmers, 10 young men and 10 young women (x age = 16.4 +/- 1.8 years) participated in a 27-day supplementation period and pre- and posttesting sessions. In session 1 (presupplementation testing), subjects swam one 50-m freestyle and then (after approximately 5 minutes of active recovery) one 100-m freestyle at maximum speed. Blood lactate was measured before and 1 minute after each swim trial. Forty-eight hours later, height, mass, and the sum of 6 skinfolds were recorded, and a Biokinetic Swim Bench total work output test (2 x 30-second trials, with a 10-minute passive recovery in between) was undertaken. After the pretests were completed, participants were divided into 2 groups (n = 10, Cr; and n = 10, placebo) by means of matched pairs on the basis of gender and 50-m swim times. A Cr loading phase of 20 g x d(-1) for 5 days was then instituted, followed by a maintenance phase of 5 g x d(-1) for 22 days. Postsupplementation testing replicated the presupplementation tests. Four weeks of Cr supplementation did not influence single sprint performance in the pool or body mass and composition. However, 30-second swim bench total work scores for trial 1 and trial 2 increased after Cr (p < 0.05) but not placebo ingestion. Postexercise blood lactate values were not different after supplementation for the 50- and 100-m sprint trials either within or between groups. It was concluded that 4 weeks of Cr supplementation did not significantly improve single sprint performance in competitive junior swimmers, but it did enhance swim bench test performance.
9. COLD CALIBRATION TEST STAND (H1) FROM LEFT TO RIGHT ...
9. COLD CALIBRATION TEST STAND (H-1) FROM LEFT TO RIGHT - WORK BENCH, CONTROL PANEL, CHEMICAL TANK. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL
Development of Fuzzy Logic Controller for Quanser Bench-Top Helicopter
NASA Astrophysics Data System (ADS)
Jafri, M. H.; Mansor, H.; Gunawan, T. S.
2017-11-01
Bench-top helicopter is a laboratory scale helicopter that usually used as a testing bench of the real helicopter behavior. This helicopter is a 3 Degree of Freedom (DOF) helicopter which works by three different axes wshich are elevation, pitch and travel. Thus, fuzzy logic controller has been proposed to be implemented into Quanser bench-top helicopter because of its ability to work with non-linear system. The objective for this project is to design and apply fuzzy logic controller for Quanser bench-top helicopter. Other than that, fuzzy logic controller performance system has been simulated to analyze and verify its behavior over existing PID controller by using Matlab & Simulink software. In this research, fuzzy logic controller has been designed to control the elevation angle. After simulation has been performed, it can be seen that simulation result shows that fuzzy logic elevation control is working for 4°, 5° and 6°. These three angles produce zero steady state error and has a fast response. Other than that, performance comparisons have been performed between fuzzy logic controller and PID controller. Fuzzy logic elevation control has a better performance compared to PID controller where lower percentage overshoot and faster settling time have been achieved in 4°, 5° and 6° step response test. Both controller are have zero steady state error but fuzzy logic controller is managed to produce a better performance in term of settling time and percentage overshoot which make the proposed controller is reliable compared to the existing PID controller.
Lu, Yehu; Song, Guowen; Wang, Faming
2015-03-01
Hot liquid hazards existing in work environments are shown to be a considerable risk for industrial workers. In this study, the predicted protection from fabric was assessed by a modified hot liquid splash tester. In these tests, conditions with and without an air spacer were applied. The protective performance of a garment exposed to hot water spray was investigated by a spray manikin evaluation system. Three-dimensional body scanning technique was used to characterize the air gap size between the protective clothing and the manikin skin. The relationship between bench scale test and manikin test was discussed and the regression model was established to predict the overall percentage of skin burn while wearing protective clothing. The results demonstrated strong correlations between bench scale test and manikin test. Based on these studies, the overall performance of protective clothing against hot water spray can be estimated on the basis of the results of the bench scale hot water splashes test and the information of air gap size entrapped in clothing. The findings provide effective guides for the design and material selection while developing high performance protective clothing. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.
NASA Astrophysics Data System (ADS)
Aksenov, A. A.; Danilishin, A. M.; Dubenko, A. M.; Kozhukov, Y. V.
2017-08-01
Design modernization of the centrifugal compressor stage test bench with three dimensional impeller blades was carried out for the possibility of holding a series of experimental studies of different 3D impeller models. The studies relates to the problem of joint work of the impeller and the stationary channels of the housing when carrying out works on modernization with the aim of improving the parameters of the volumetric capacity or pressure in the presence of design constraints. The object of study is the experimental single end centrifugal compressor stage with the 3D impeller. Compressor stage consists of the 3D impeller, vaneless diffuser (VLD), outlet collector - folded side scroll and downstream pipe. The drive is a DC motor 75 kW. The increase gear (multiplier) was set between the compressor and DC motor, gear ratio is i = 9.8. To obtain the characteristics of the compressor and the flow area the following values were measured: total pressure, static pressure, direction (angles) of the stream in different cross sections. Additional pneumometric probes on the front wall of the VLD of the test bench have been installed. Total pressure probes and foster holes for the measurement of total and static pressure by the new drainage scheme. This allowed carrying out full experimental studies for two elements of centrifugal compressor stage. After the experimental tests the comprehensive information about the performance of model stage were obtained. Was measured geometric parameters and the constructed virtual model of the experimental bench flow part with the help of Creo Parametric 3.0 and ANSYS v. 16.2. Conducted CFD calculations and verification with experimental data. Identifies the steps for further experimental and virtual works.
Novel Electrochemical Test Bench for Evaluating the Functional Fatigue Life of Biomedical Alloys
NASA Astrophysics Data System (ADS)
Ijaz, M. F.; Dubinskiy, S.; Zhukova, Y.; Korobkova, A.; Pustov, Y.; Brailovski, V.; Prokoshkin, S.
2017-08-01
The aim of the present work was first to develop and validate a test bench that simulates the in vitro conditions to which the biomedical implants will be actually subjected in vivo. For the preliminary application assessments, the strain-controlled fatigue tests of biomedically pure Ti and Ti-Nb-Zr alloy in simulated body fluid were undertaken. The in situ open-circuit potential measurements from the test bench demonstrated a strong dependence on the dynamic cycling and kind of material under testing. The results showed that during fatigue cycling, the passive oxide film formed on the surface of Ti-Nb-Zr alloy was more resistant to fatigue degradation when compared with pure Ti. The Ti-Nb-Zr alloy exhibited prolonged fatigue life when compared with pure Ti. The fractographic features of both materials were also characterized using scanning electron microscopy. The electrochemical results and the fractographic evidence confirmed that the prolonged functional fatigue life of the Ti-Nb-Zr alloy is apparently ascribable to the reversible martensitic phase transformation.
Ohta, Masanori; Eguchi, Yasumasa; Inoue, Tomohiro; Honda, Toru; Morita, Yusaku; Konno, Yoshimasa; Yamato, Hiroshi; Kumashiro, Masaharu
2015-01-01
Work ability is partly determined by physical and mental fitness. Bench step exercise can be practiced anywhere at any time. The aim of this study was to determine the effects of a bench step exercise on work ability by examining cardiovascular risk factors and oxidative stress. Thirteen volunteers working in a warehousing industry comprised the bench step exercise group (n=7) and the control group (n=6). The participants in the step exercise group were encouraged to practice the step exercise at home for 16 weeks. The step exercise improved glucose metabolism and antioxidative capacity and increased work ability by reducing absences from work and improving the prognosis of work ability. The improvement in work ability was related to a reduction in oxidative stress. These results suggest that a bench step exercise may improve work ability by reducing cardiovascular risk factors and oxidative stress.
Tørhaug, T; Brurok, B; Hoff, J; Helgerud, J; Leivseth, G
2016-10-01
To assess the effect from maximal bench press strength training (MST) on wheelchair propulsion work economy (WE). Pretest-posttest case-control group design. St Olavs Hospital, Trondheim, Norway. Seventeen male individuals with spinal cord injury (SCI) paraplegia were allocated to either MST bench press (n=11) or the control group (CG) (n=7). The MST group trained bench press three times per week, for 6 weeks, starting at 85-95% of their pretest bench press one-repetition maximum (1RM). For calculation of WE during wheelchair propulsion, oxygen uptake (VO 2 ) measurements were collected during wheelchair ergometry (WCE) at submaximal workload of 50 W. Similarly, peak oxygen uptake (VO 2peak ) and peak power output (W) were measured during WCE. Individuals in the MST regimen significantly improved WE compared with the CG by 17.3 % (mean between-group differences: 95% confidence interval) of 2.63 ml kg -1 min -1 : (-4.34, -0.91) (P=0.007). Between pretest and posttest, the increase in bench press 1RM was by 17% higher in the MST group compared with the CG. At peak testing, the MST group generated significantly higher peak power compared with the CG. All other physiological variables were comparable within and between groups. A 6-week MST bench press regimen significantly improved WE during wheelchair propulsion at 50 W workload. These preliminary data support a possible beneficial role for MST to reduce the energy cost of wheelchair propulsion for SCI individuals.
Kreissel, K; Bösl, M; Lipp, P; Franzreb, M; Hambsch, B
2012-01-01
To determine the removal efficiency of ultrafiltration (UF) membranes for nano-particles in the size range of viruses the state of the art uses challenge tests with virus-spiked water. This work focuses on bench-scale and semi-technical scale experiments. Different experimental parameters influencing the removal efficiency of the tested UF membrane modules were analyzed and evaluated for bench- and semi-technical scale experiments. Organic matter in the water matrix highly influenced the removal of the tested bacteriophages MS2 and phiX174. Less membrane fouling (low ΔTMP) led to a reduced phage reduction. Increased flux positively affected phage removal in natural waters. The tested bacteriophages MS2 and phiX174 revealed different removal properties. MS2, which is widely used as a model organism to determine virus removal efficiencies of membranes, mostly showed a better removal than phiX174 for the natural water qualities tested. It seems that MS2 is possibly a less conservative surrogate for human enteric virus removal than phiX174. In bench-scale experiments log removal values (LRV) for MS2 of 2.5-6.0 and of 2.5-4.5 for phiX174 were obtained for the examined range of parameters. Phage removal obtained with differently fabricated semi-technical modules was quite variable for comparable parameter settings, indicating that module fabrication can lead to differing results. Potting temperature and module size were identified as influencing factors. In conclusion, careful attention has to be paid to the choice of experimental settings and module potting when using bench-scale or semi-technical scale experiments for UF membrane challenge tests.
Errors of car wheels rotation rate measurement using roller follower on test benches
NASA Astrophysics Data System (ADS)
Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.
2018-03-01
The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.
Dynamic MTF, an innovative test bench for detector characterization
NASA Astrophysics Data System (ADS)
Emmanuel, Rossi; Raphaël, Lardière; Delmonte, Stephane
2017-11-01
PLEIADES HR are High Resolution satellites for Earth observation. Placed at 695km they reach a 0.7m spatial resolution. To allow such performances, the detectors are working in a TDI mode (Time and Delay Integration) which consists in a continuous charge transfer from one line to the consecutive one while the image is passing on the detector. The spatial resolution, one of the most important parameter to test, is characterized by the MTF (Modulation Transfer Function). Usually, detectors are tested in a staring mode. For a higher level of performances assessment, a dedicated bench has been set-up, allowing detectors' MTF characterization in the TDI mode. Accuracy and reproducibility are impressive, opening the door to new perspectives in term of HR imaging systems testing.
NASA Technical Reports Server (NTRS)
LEGRAND
1987-01-01
The rocket test benches are used to study burnup behavior by various methods. In the first ten months of 1966, 1578 shots were performed to test propellants, and 920 to test 14 thrust and pressure measurement projects.
Acute Effects of the Elevation Training Mask on Strength Performance in Recreational Weight lifters.
Jagim, Andrew R; Dominy, Trevor A; Camic, Clayton L; Wright, Glenn; Doberstein, Scott; Jones, Margaret T; Oliver, Jonathan M
2018-02-01
Jagim, AR, Dominy, TA, Camic, CL, Wright, G, Doberstein, S, Jones, MT, and Oliver, JM. Acute effects of the elevation training mask on strength performance in recreational weightlifters. J Strength Cond Res 32(2): 482-489, 2018-The Elevation Training Mask 2.0 (ETM) is a novel device that purportedly simulates altitude training. The purpose of this study was to investigate the acute effects of the ETM on resistance exercise performance, metabolic stress markers, and ratings of mental fatigue. Twenty male recreational weight lifters completed 2 training sessions of back squat and bench press (6 sets of 10 repetitions at 85% of 5-repetition maximum and seventh set to failure) as well as a maximal effort sprint test (18% body mass) with the mask (ETM) and without the mask (NM). Training evaluation included baseline and postexercise blood lactate and oxygen saturation measures. Performance evaluation included peak and average velocity bar velocity, total volume load, total work, total repetitions completed, and sprint performance. Adverse side effects were reported in 12% (n = 3) of participants, which included feelings of light headedness, anxiety, and discomfort. No differences were found in repetitions or total workload in back squat (p = 0.07) or bench press (p = 0.08) between conditions. A lower peak velocity was identified during the back squat, bench press, and sprint test in the ETM condition (p = 0.04). Blood lactate values were lower after bench press and sprint during the ETM condition (p < 0.001). Significantly lower ratings of alertness and focus for task were found after squat, bench press, and sprint test in the ETM condition compared with the NM condition (p < 0.001). Wearing the ETM during bouts of resistance training did not hinder the ability to achieve desired training volumes during the resistance training session. However, wearing the ETM does seem to attenuate the ability to maintain working velocity during training bouts and negatively influence ratings of alertness and focus for task.
Comparative tests of bench equipment for fuel control system testing of gas-turbine engine
NASA Astrophysics Data System (ADS)
Shendaleva, E. V.
2018-04-01
The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.
Patterson, Jeffrey M.; Oppenheimer, Nicole E.; Feser, Erin H.
2015-01-01
Training the bench press exercise on a traditional flat bench does not induce a level of instability as seen in sport movements and activities of daily living. Twenty participants were recruited to test two forms of instability: using one dumbbell rather than two and lifting on the COR bench compared to a flat bench. Electromyography (EMG) amplitudes of the pectoralis major, middle trapezius, external oblique, and internal oblique were recorded and compared. Differences in range of motion (ROM) were evaluated by measuring an angular representation of the shoulder complex. Four separate conditions of unilateral bench press were tested while lifting on a: flat bench with one dumbbell, flat bench with two dumbbells, COR Bench with one dumbbell, and COR Bench with two dumbbells. The results imply that there are no differences in EMG amplitude or ROM between the COR bench and traditional bench. However, greater ROM was found to be utilized in the single dumbbell condition, both in the COR bench and the flat bench. PMID:26528421
Lorentz- and CPT-symmetry studies in subatomic physics
NASA Astrophysics Data System (ADS)
Lehnert, Ralf
2016-12-01
Subatomic systems provide an exquisite test bench for spacetime symmetries. This work motivates such measurements, reviews the effective field theory test framework for the description of Lorentz and CPT violation, and employs this framework to study the phenomenology of spacetime-symmetry breaking in various subatomic systems.
1996-01-01
Real-Time 19 5 Conclusion 23 List of References 25 ii LIST OF FIGURES FIGURE PAGE 3-1 Test Bench Pseudo Code 7 3-2 Fast Convolution...3-1 shows pseudo - code for a test bench with two application nodes. The outer test bench wrapper consists of three functions: pipeline_init, pipeline...exit_func); Figure 3-1. Test Bench Pseudo Code The application wrapper is contained in the pipeline routine and similarly consists of an
The Relationship between Trunk Function and Injury among Junior High School Soccer Players
Nakazawa, Rie; Endo, Yasuhiro; Sakamoto, Masaaki
2013-01-01
[Purpose] The purpose of this study was to examine the relationship between trunk stability and injury among young soccer players. [Subjects and Methods] The subjects were 19 male soccer players in junior high school. The presence of injury was noted, and trunk stability was measured by using the bench test and sideways bench test, which were modified from “The 11+” exercises. [Results] There was no significant difference in endurance time in the bench test or sideways bench test between the injury group (n=9) and non-injury group (n=10). Comparison within each group revealed no significant difference in endurance time between the right and left sideways bench tests in the non-injury group; however, the time in the left sideways bench test was significantly longer than that in the right in the injury group. [Conclusion] This study suggests that there is a relationship between asymmetric trunk stability and injury. Further research investigating the relationship between asymmetric trunk function and balance skills is necessary. PMID:24259850
Design and construction of a telescope simulator for LISA optical bench testing
NASA Astrophysics Data System (ADS)
Bogenstahl, J.; Tröbs, M.; d'Arcio, L.; Diekmann, C.; Fitzsimons, E. D.; Hennig, J. S.; Hey, F. G.; Killow, C. J.; Lieser, M.; Lucarelli, S.; Perreur-Lloyd, M.; Pijnenburg, J.; Robertson, D. I.; Taylor, A.; Ward, H.; Weise, D.; Heinzel, G.; Danzmann, K.
2017-11-01
LISA (Laser Interferometer Space Antenna) is a proposed space-based instrument for astrophysical observations via the measurement of gravitational waves at mHz frequencies. The triangular constellation of the three LISA satellites will allow interferometric measurement of the changes in distance along the arms. On board each LISA satellite there will be two optical benches, one for each testmass, that measure the distance to the local test mass and to the remote optical bench on the distant satellite. For technology development, an Optical Bench Elegant Bread Board (OB EBB) is currently under construction. To verify the performance of the EBB, another optical bench - the so-called telescope simulator bench - will be constructed to simulate the beam coming from the far spacecraft. The optical beam from the telescope simulator will be superimposed with the light on the LISA OB, in order to simulate the link between two LISA satellites. Similarly in reverse, the optical beam from the LISA OB will be picked up and measured on the telescope simulator bench. Furthermore, the telescope simulator houses a test mass simulator. A gold coated mirror which can be manipulated by an actuator simulates the test mass movements. This paper presents the layout and design of the bench for the telescope simulator and test mass simulator.
Development and marketing of a prosthetic urinary control valve system
NASA Technical Reports Server (NTRS)
Tenney, J. B., Jr.; Rabinowitz, R.; Rogers, D. W.; Harrison, H. N.
1983-01-01
An implantable prosthetic for the control of urinary incontinence was developed and marketed. Three phases are presented: bench development studies, animal trials, and human clinical trials. This work was performed under the direction of a Research Team at Rochester General Hospital (RGH). Bench trials were completed on prototype hardware and provided early verification of the device's ability to withstand repeated cyclic testing. Configurational variants were evaluated and a preferred design concept was established. Silicone rubber (medical grade) was selected as the preferred material for the prosthesis.
The development of a repetition-load scheme for the eccentric-only bench press exercise.
Moir, Gavin L; Erny, Kyle F; Davis, Shala E; Guers, John J; Witmer, Chad A
2013-01-01
The purpose of the present study was to develop a repetition-load scheme for the eccentric-only bench press exercise. Nine resistance trained men (age: 21.6 ± 1.0 years; 1-repetition maximum [RM] bench press: 137.7 ± 30.4 kg) attended four testing sessions during a four week period. During the first session each subject's 1-RM bench press load utilizing the stretch-shortening cycle was determined. During the remaining sessions they performed eccentric-only repetitions to failure using supra-maximal loads equivalent to 110%, 120% and 130% of their 1-RM value with a constant cadence (30 reps·min(-1)). Force plates and a three dimensional motion analysis system were used during these final three sessions in order to evaluate kinematic and kinetic variables. More repetitions were completed during the 110% 1-RM condition compared to the 130% 1-RM condition (p=0.01). Mean total work (p=0.046) as well as vertical force (p=0.049), vertical work (p=0.017), and vertical power output (p=0.05) were significantly greater during the 130% 1-RM condition compared to the 110% 1-RM condition. A linear function was fitted to the number of repetitions completed under each load condition that allowed the determination of the maximum number of repetitions that could be completed under other supra-maximal loads. This linear function predicted an eccentric-only 1-RM in the bench press with a load equivalent to 164.8% 1-RM, producing a load of 227.0 ± 50.0 kg. The repetition-load scheme presented here should provide a starting point for researchers to investigate the kinematic, kinetic and metabolic responses to eccentric-only bench press workouts.
The Development of a Repetition-Load Scheme for the Eccentric-Only Bench Press Exercise
Moir, Gavin L.; Erny, Kyle F.; Davis, Shala E.; Guers, John J.; Witmer, Chad A.
2013-01-01
The purpose of the present study was to develop a repetition-load scheme for the eccentric-only bench press exercise. Nine resistance trained men (age: 21.6 ± 1.0 years; 1-repetition maximum [RM] bench press: 137.7 ± 30.4 kg) attended four testing sessions during a four week period. During the first session each subject’s 1-RM bench press load utilizing the stretch-shortening cycle was determined. During the remaining sessions they performed eccentric-only repetitions to failure using supra-maximal loads equivalent to 110%, 120% and 130% of their 1-RM value with a constant cadence (30 reps·min−1). Force plates and a three dimensional motion analysis system were used during these final three sessions in order to evaluate kinematic and kinetic variables. More repetitions were completed during the 110% 1-RM condition compared to the 130% 1-RM condition (p=0.01). Mean total work (p=0.046) as well as vertical force (p=0.049), vertical work (p=0.017), and vertical power output (p=0.05) were significantly greater during the 130% 1-RM condition compared to the 110% 1-RM condition. A linear function was fitted to the number of repetitions completed under each load condition that allowed the determination of the maximum number of repetitions that could be completed under other supra-maximal loads. This linear function predicted an eccentric-only 1-RM in the bench press with a load equivalent to 164.8% 1-RM, producing a load of 227.0 ± 50.0 kg. The repetition-load scheme presented here should provide a starting point for researchers to investigate the kinematic, kinetic and metabolic responses to eccentric-only bench press workouts. PMID:24235981
A comparison of muscle activation between a Smith machine and free weight bench press.
Schick, Evan E; Coburn, Jared W; Brown, Lee E; Judelson, Daniel A; Khamoui, Andy V; Tran, Tai T; Uribe, Brandon P
2010-03-01
The bench press exercise exists in multiple forms including the machine and free weight bench press. It is not clear though how each mode differs in its effect on muscle activation. The purpose of this study was to compare muscle activation of the anterior deltoid, medial deltoid, and pectoralis major during a Smith machine and free weight bench press at lower (70% 1 repetition maximum [1RM]) and higher (90% 1RM) intensities. Normalized electromyography amplitude values were used during the concentric phase of the bench press to compare muscle activity between a free weight and Smith machine bench press. Participants were classified as either experienced or inexperienced bench pressers. Two testing sessions were used, each of which entailed either all free weight or all Smith machine testing. In each testing session, each participant's 1RM was established followed by 2 repetitions at 70% of 1RM and 2 repetitions at 90% of 1RM. Results indicated greater activation of the medial deltoid on the free weight bench press than on the Smith machine bench press. Also, there was greater muscle activation at the 90% 1RM load than at the 70% 1RM load. The results of this study suggest that strength coaches should consider choosing the free weight bench press over the Smith machine bench press because of its potential for greater upper-body muscular development.
Usage of DNA Fingerprinting Technology for Quality Control in Molecular Lab Bench Work.
McIntosh, Linda Y; Lal, Janella E; Qin, Dahui
2018-01-01
One of the major quality assurance (QA) goals in many molecular laboratories is to avoid sample pipetting errors on the lab bench; especially when pipetting into multiwell plates. A pipetting error can cause a switch in patient samples, which can lead to recording the wrong results for the patient samples involved. Such pipetting errors are difficult to identify when it happens in lab bench work. DNA fingerprinting is a powerful tool in determining sample identities. Our laboratory has explored the usage of this technology in our QA process and successfully established that DNA fingerprinting can be used to monitor possible sample switch in gene rearrangement lab bench work. We use florescent light to quench the florescence in the gene rearrangement polymerase chain reaction products. After that, DNA fingerprinting technology is used to identify the sample DNA in the gene rearrangement polymerase chain reaction plate. The result is compared with the corresponding patient's blood sample DNA to determine whether there is a sample switch during the lab bench work.
The first purpose of this project is to complete bench and pilot scale testing of promising mercury sorbents. This work would apply findings from fundamental, mechanistic efforts over the past three years that have developed sorbents which show improved capture of elemental and ...
MINIPILOT SOLAR SYSTEM: DESIGN/OPERATION OF SYSTEM AND RESULTS OF NON-SOLAR TESTING AT MRI
Prior to this project, MRI had carried out work for the Environmental Protection Agency (EPA) on the conceptual design of a solar system for solid waste disposal and a follow-on project to study the feasibility of bench-scale testing of desorption of organics from soil with destr...
Contextual interference effects on the acquisition of skill and strength of the bench press.
Naimo, Marshall A; Zourdos, Michael C; Wilson, Jacob M; Kim, Jeong-Su; Ward, Emery G; Eccles, David W; Panton, Lynn B
2013-06-01
The purpose of this study was to investigate contextual interference effects on skill acquisition and strength gains during the learning of the bench press movement. Twenty-four healthy, college-aged males and females were stratified to control, high contextual interference (HCI), and low contextual interference (LCI) groups. Treatment groups were provided with written and visual instruction on proper bench press form and practiced the bench press and dart throwing for four weeks. Within each session, LCI performed all bench press sets before undertaking dart-throws. HCI undertook dart-throws immediately following each set of bench press. Control only did testing. Measurements, including one repetition maximum (1RM), checklist scores based on video recordings of participants' 1RM's, and dart-throw test scores were taken at pre-test, 1 week, 2 week, post-test, and retention test. Results were consistent with the basic premise of the contextual interference effect. LCI had significant improvements in percent 1RM and checklist scores during training, but were mostly absent after training (post-test and retention test). HCI had significant improvements in percent 1RM and checklist scores both during and after training. Thus, HCI may augment strength and movement skill on the bench press since proper technique is an important component of resistance exercise movements. Copyright © 2013 Elsevier B.V. All rights reserved.
This report presents the results of bench-scale testing on degradation of 2,3,7,8-TCDD using W photolysis, and PCB degradation using UV photolysis, chemical oxidation and biological treatment. Bench-scale tests were conducted to investigate the feasibility of a two-phase detoxifi...
A Lightweight, Precision-Deployable, Optical Bench for High Energy Astrophysics Missions
NASA Astrophysics Data System (ADS)
Danner, Rolf; Dailey, D.; Lillie, C.
2011-09-01
The small angle of total reflection for X-rays, forcing grazing incidence optics with large collecting areas to long focal lengths, has been a fundamental barrier to the advancement of high-energy astrophysics. Design teams around the world have long recognized that a significant increase in effective area beyond Chandra and XMM-Newton requires either a deployable optical bench or separate X-ray optics and instrument module on formation flying spacecraft. Here, we show that we have in hand the components for a lightweight, precision-deployable optical bench that, through its inherent design features, is the affordable path to the next generation of imaging high-energy astrophysics missions. We present our plans for a full-scale engineering model of a deployable optical bench for Explorer-class missions. We intend to use this test article to raise the technology readiness level (TRL) of the tensegrity truss for a lightweight, precision-deployable optical bench for high-energy astrophysics missions from TRL 3 to TRL 5 through a set of four well-defined technology milestones. The milestones cover the architecture's ability to deploy and control the focal point, characterize the deployed dynamics, determine long-term stability, and verify the stowed load capability. Our plan is based on detailed design and analysis work and the construction of a first prototype by our team. Building on our prior analysis and the high TRL of the architecture components we are ready to move on to the next step. The key elements to do this affordably are two existing, fully characterized, flight-quality, deployable booms. After integrating them into the test article, we will demonstrate that our architecture meets the deployment accuracy, adjustability, and stability requirements. The same test article can be used to further raise the TRL in the future.
Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016
NASA Astrophysics Data System (ADS)
Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas
2017-06-01
A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
Measure Twice, Build Once: Bench-Scale Testing to Evaluate Bioretention Media Design
The paper discusses the utility of conducting bench-scale testing on selected bioretention media and media amendments to validate hydrologic properties before installing media and amendments in larger pilot- or full-scale rain garden installations. The bench-scale study conclude...
Piezoelectric energy harvesting computer controlled test bench
NASA Astrophysics Data System (ADS)
Vázquez-Rodriguez, M.; Jiménez, F. J.; de Frutos, J.; Alonso, D.
2016-09-01
In this paper a new computer controlled (C.C.) laboratory test bench is presented. The patented test bench is made up of a C.C. road traffic simulator, C.C. electronic hardware involved in automating measurements, and test bench control software interface programmed in LabVIEW™. Our research is focused on characterizing electronic energy harvesting piezoelectric-based elements in road traffic environments to extract (or "harvest") maximum power. In mechanical to electrical energy conversion, mechanical impacts or vibrational behavior are commonly used, and several major problems need to be solved to perform optimal harvesting systems including, but no limited to, primary energy source modeling, energy conversion, and energy storage. It is described a novel C.C. test bench that obtains, in an accurate and automatized process, a generalized linear equivalent electrical model of piezoelectric elements and piezoelectric based energy store harvesting circuits in order to scale energy generation with multiple devices integrated in different topologies.
Piezoelectric energy harvesting computer controlled test bench.
Vázquez-Rodriguez, M; Jiménez, F J; de Frutos, J; Alonso, D
2016-09-01
In this paper a new computer controlled (C.C.) laboratory test bench is presented. The patented test bench is made up of a C.C. road traffic simulator, C.C. electronic hardware involved in automating measurements, and test bench control software interface programmed in LabVIEW™. Our research is focused on characterizing electronic energy harvesting piezoelectric-based elements in road traffic environments to extract (or "harvest") maximum power. In mechanical to electrical energy conversion, mechanical impacts or vibrational behavior are commonly used, and several major problems need to be solved to perform optimal harvesting systems including, but no limited to, primary energy source modeling, energy conversion, and energy storage. It is described a novel C.C. test bench that obtains, in an accurate and automatized process, a generalized linear equivalent electrical model of piezoelectric elements and piezoelectric based energy store harvesting circuits in order to scale energy generation with multiple devices integrated in different topologies.
Portable bench tester for piezo weigh-in-motion equipment : final report, June 2006.
DOT National Transportation Integrated Search
2006-06-01
The Ohio Department of Transportation's (ODOT) piezo weigh-in-motion (WIM) equipment must be tested for initial working operation and to insure continued correct operation. Currently, the only available method to verify the vehicle classification par...
Development of remote data acquisition system based on OPC for brake test bench
NASA Astrophysics Data System (ADS)
Wang, Yiwei; Wu, Mengling; Tian, Chun; Ma, Tianhe
2017-08-01
The 1:1 train brake system test bench can be used to carry out brake-related adhesion-slid control, stability test, noise test and dynamic test. To collect data of the test bench, a data acquisition method is needed. In this paper, the remote data acquisition system of test bench is built by LabVIEW based on OPC technology. Unlike the traditional hardwire way connecting PLC acquisition module with sensors, the novel method is used to collect data and share them through the internal LAN built by Ethernet switches, which avoids the complex wiring interference in an easy, efficient and flexible way. The system has been successfully applied to the data acquisition activities of the comprehensive brake system test bench of CRRC Nanjing Puzhen Haitai Brake Equipment Co., Ltd., and the relationship test between the adhesion coefficient and the slip-ratio is realized. The speed signal, torque signal and brake disc temperature can be collected and displayed. The results show that the system is reliable, convenient, and efficient, and can meet the requirements of data acquisition.
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.
Aziz, Nazneen; Zhao, Qin; Bry, Lynn; Driscoll, Denise K; Funke, Birgit; Gibson, Jane S; Grody, Wayne W; Hegde, Madhuri R; Hoeltge, Gerald A; Leonard, Debra G B; Merker, Jason D; Nagarajan, Rakesh; Palicki, Linda A; Robetorye, Ryan S; Schrijver, Iris; Weck, Karen E; Voelkerding, Karl V
2015-04-01
The higher throughput and lower per-base cost of next-generation sequencing (NGS) as compared to Sanger sequencing has led to its rapid adoption in clinical testing. The number of laboratories offering NGS-based tests has also grown considerably in the past few years, despite the fact that specific Clinical Laboratory Improvement Amendments of 1988/College of American Pathologists (CAP) laboratory standards had not yet been developed to regulate this technology. To develop a checklist for clinical testing using NGS technology that sets standards for the analytic wet bench process and for bioinformatics or "dry bench" analyses. As NGS-based clinical tests are new to diagnostic testing and are of much greater complexity than traditional Sanger sequencing-based tests, there is an urgent need to develop new regulatory standards for laboratories offering these tests. To develop the necessary regulatory framework for NGS and to facilitate appropriate adoption of this technology for clinical testing, CAP formed a committee in 2011, the NGS Work Group, to deliberate upon the contents to be included in the checklist. Results . -A total of 18 laboratory accreditation checklist requirements for the analytic wet bench process and bioinformatics analysis processes have been included within CAP's molecular pathology checklist (MOL). This report describes the important issues considered by the CAP committee during the development of the new checklist requirements, which address documentation, validation, quality assurance, confirmatory testing, exception logs, monitoring of upgrades, variant interpretation and reporting, incidental findings, data storage, version traceability, and data transfer confidentiality.
Wang, Zhe; Lv, Haoliang; Zhou, Xiaojun; Chen, Zhaomeng; Yang, Yong
2018-06-21
Dual-motor Electric Drive Tracked Vehicles (DDTVs) have attracted increasing attention due to their high transmission efficiency and economical fuel consumption. A test bench for the development and validation of new DDTV technologies is necessary and urgent. How to load the vehicle on a DDTV test bench exactly the same as on a real road is a crucial issue when designing the bench. This paper proposes a novel dynamic load emulation method to address this problem. The method adopts dual dynamometers to simulate both the road load and the inertia load that are imposed on the dual independent drive systems. The vehicle’s total inertia equivalent to the drive wheels is calculated with separate consideration of vehicle body, tracks and road wheels to obtain a more accurate inertia load. A speed tracking control strategy with feedforward compensation is implemented to control the dual dynamometers, so as to make the real-time dynamic load emulation possible. Additionally, a MATLAB/Simulink model of the test bench is built based on a dynamics analysis of the platform. Experiments are finally carried out on this test bench under different test conditions. The outcomes show that the proposed load emulation method is effective, and has good robustness and adaptability to complex driving conditions. Besides, the accuracy of the established test bench model is also demonstrated by comparing the results obtained from the simulation model and experiments.
14. PIPE MACHINE, WORK BENCH, SCALE, RADIAL DRILL AND STOVE ...
14. PIPE MACHINE, WORK BENCH, SCALE, RADIAL DRILL AND STOVE (L TO R) LOOKING WEST. - W. A. Young & Sons Foundry & Machine Shop, On Water Street along Monongahela River, Rices Landing, Greene County, PA
13. Interior view of individual work benches along west wall ...
13. Interior view of individual work benches along west wall of north 1922 section of Building 59. Camera pointed NW. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA
Static and moving solid/gas interface modeling in a hybrid rocket engine
NASA Astrophysics Data System (ADS)
Mangeot, Alexandre; William-Louis, Mame; Gillard, Philippe
2018-07-01
A numerical model was developed with CFD-ACE software to study the working condition of an oxygen-nitrogen/polyethylene hybrid rocket combustor. As a first approach, a simplified numerical model is presented. It includes a compressible transient gas phase in which a two-step combustion mechanism is implemented coupled to a radiative model. The solid phase from the fuel grain is a semi-opaque material with its degradation process modeled by an Arrhenius type law. Two versions of the model were tested. The first considers the solid/gas interface with a static grid while the second uses grid deformation during the computation to follow the asymmetrical regression. The numerical results are obtained with two different regression kinetics originating from ThermoGravimetry Analysis and test bench results. In each case, the fuel surface temperature is retrieved within a range of 5% error. However, good results are only found using kinetics from the test bench. The regression rate is found within 0.03 mm s-1 and average combustor pressure and its variation over time have the same intensity than the measurements conducted on the test bench. The simulation that uses grid deformation to follow the regression shows a good stability over a 10 s simulated time simulation.
Universal Verification Methodology Based Register Test Automation Flow.
Woo, Jae Hun; Cho, Yong Kwan; Park, Sun Kyu
2016-05-01
In today's SoC design, the number of registers has been increased along with complexity of hardware blocks. Register validation is a time-consuming and error-pron task. Therefore, we need an efficient way to perform verification with less effort in shorter time. In this work, we suggest register test automation flow based UVM (Universal Verification Methodology). UVM provides a standard methodology, called a register model, to facilitate stimulus generation and functional checking of registers. However, it is not easy for designers to create register models for their functional blocks or integrate models in test-bench environment because it requires knowledge of SystemVerilog and UVM libraries. For the creation of register models, many commercial tools support a register model generation from register specification described in IP-XACT, but it is time-consuming to describe register specification in IP-XACT format. For easy creation of register model, we propose spreadsheet-based register template which is translated to IP-XACT description, from which register models can be easily generated using commercial tools. On the other hand, we also automate all the steps involved integrating test-bench and generating test-cases, so that designers may use register model without detailed knowledge of UVM or SystemVerilog. This automation flow involves generating and connecting test-bench components (e.g., driver, checker, bus adaptor, etc.) and writing test sequence for each type of register test-case. With the proposed flow, designers can save considerable amount of time to verify functionality of registers.
Bench press exercise: the key points.
Padulo, J; Laffaye, G; Chaouachi, A; Chamari, K
2015-06-01
The bench press exercise (BPE) is receiving increasing interest as a field testing, training/therapeutic modality to improve neuromuscular performance or to increase bone mass density. Several studies have been performed using BPE as a standard for increasing upper-limb strength. For this purpose, the position of the bar, the loads, the sets, the number of repetitions, the recovery time in-between sets, the movement speed, the muscular work and the use of the determination of the one repetition maximum (1-RM) are the classical tools investigated in the literature that have been shown to affect the BPE effect on neuromuscular. The goal of the present short review is to make a picture of the current knowledge on the bench press exercise, which could be very helpful for a better understanding of this standard movement and its effects. Based on the related literature, several recommendations on these key points are presented here.
Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight
NASA Technical Reports Server (NTRS)
Ryder, Jeffrey W.; Wickwire, P. J.; Buxton, R. E.; Bloomberg, J. J.; Ploutz-Snyder, L.
2011-01-01
The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.
Test benches for studying the properties of car tyres
NASA Astrophysics Data System (ADS)
Kuznetsov, N. Yu.; Fedotov, A. I.; Vlasov, V. G.
2017-12-01
The article describes the design of the measuring systems of test benches used to study the properties of elastic tyres. The bench has two autonomous systems - for testing the braking properties of elastic tyres rolling in a plane parallel way and for testing tyre slip properties. The system for testing braking properties determines experimental characteristics of elastic tyres as the following dependencies: longitudinal response vs time, braking torque vs slip, angular velocity vs slip, and longitudinal response vs slip. The system for studying tyre slip properties determines both steady (dependence of the lateral response in a contact area on the slipping angle) and non-steady characteristics (time variation of the slipping angle as a result of turning from -40 to +40 degrees) of tyre slip. The article presents the diagrams of bench tests of elastic tyres. The experimental results show metrological parameters and functional capabilities of the bench for studying tyre properties in driving and braking modes. The metrological indices of the recorded parameters of the measuring system for studying tyre properties are presented in the table.
A rolling-sliding bench test for investigating rear axle lubrication
Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.; ...
2018-02-07
An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less
A rolling-sliding bench test for investigating rear axle lubrication
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.
An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-10
... running to unintended areas, etc. Wound dehiscence Bench Testing, Shelf Life Testing, Animal Testing, Clinical Studies, Labeling. Adverse tissue reaction and chemical Biocompatibility Animal burns. Testing, Clinical Studies. Infection Bench Testing, Biocompatibility Animal Testing, Clinical Studies, Sterility...
30 CFR 57.22230 - Weekly testing (II-A mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
... 57.22230 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Safety... following locations: (1) Active mining faces and benches; (2) Main returns; (3) Returns from idle workings...
Performance and durability testing of parabolic trough receivers
NASA Astrophysics Data System (ADS)
Lei, Dongqiang; Fu, Xuqiang; Zhao, Dongming; Yuan, Guofeng; Wang, Zhifeng; Guo, Minghuan
2017-06-01
The paper describes the key performance and durability testing facilities of the parabolic trough receiver developed by Institute of Electrical Engineering, Chinese Academy of Sciences. The indoor heat loss test can be applied at 4-7 different temperature levels within 200-550 on receivers. The optical efficiency test bench consists of 12 metal halide lamps as the solar simulator and a 5 m length half-elliptical cylinder reflector with flat end reflectors. 3 ultra-precision temperature sensors are used in receiver each end to get the temperature difference. The residual gas analysis test bench is applied to analyze and predict the vacuum lifetime of the receiver. It can test the variations of composition and partial pressure of residual gases with temperature and time in the receiver annulus space by a high sensitivity quadrupole mass spectrometer gas analyzer. A coating accelerated ageing test bench, which is also used to test the thermal cycle, has been developed. This test bench uses the absorber tube of the recevier as the resistance heater to heat up the whole receiver. The coating lifetime can be predicted by the Arrhenius parameters. For the cycling test, the compressed air is used to directly cool the inner surface of the absorber tube. The thermal cycling test is performed with temperature cycles from 150 °C to 450 °C for 160 cycles. The maximum thermal cycling frequency is 8 cycles per day. The mechanical fatigue test bench is used to test the bellows and the glass-to-metal seals durability at the same time. Both bellows are expanded and compressed to 6.5 mm in turn with 10,000 cycles. A new rotating test bench was also developed to test the thermal efficiency of the receiver.
13. SOUTHEAST TO SUCKER ROD WORK BENCH AND WOODEN SUCKER ...
13. SOUTHEAST TO SUCKER ROD WORK BENCH AND WOODEN SUCKER ROD STORAGE RACKS ALONG EAST WALL OF FACTORY INTERIOR. AT THIS BENCH WORKERS RIVETED THREADED WROUGHT IRON CONNECTORS TO THE ENDS OF 20' LONG WOODEN SUCKER RODS (THE RODS WHICH EXTEND DOWNWARD IN THE WELL FROM THE GROUND SURFACE TO PISTON DISPLACEMENT PUMPS WHICH ACTUALLY ELEVATE WATER TO THE SURFACE). ROZNOR HEATER AT THE FAR RIGHT WAS ADDED CIRCA 1960. - Kregel Windmill Company Factory, 1416 Central Avenue, Nebraska City, Otoe County, NE
Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto
2014-01-01
Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653
A nuclear scanning method for estimating wear level nonuniformities
NASA Astrophysics Data System (ADS)
Ivanov, E. A.; Pascovici, G.; Racolta, P. M.
1993-09-01
The residual radioactivity measuring method has been upgraded to estimate wear level nonuniformities in the circumference of a piston ring after a certain working time in the combustion engine testing bench. The piston ring was irradiated by the thin layer activation (TLA) technique and its radioactivity was continuously monitored.
Recovery of pectoralis major and triceps brachii after bench press exercise.
Ferreira, Diogo V; Gentil, Paulo; Soares, Saulo Rodrigo Sampaio; Bottaro, Martim
2017-11-01
The present study evaluated and compared the recovery of pectoralis major (PM) and triceps brachii (TB) muscles of trained men after bench press exercise. Eighteen volunteers performed eight sets of bench press exercise to momentary muscle failure and were evaluated for TB and PM peak torque and total work on an isokinetic dynamometer. PM peak torque and total work remained lower than baseline for 72 and 96 h, respectively. TB peak torque was only different from baseline immediately post training, while total work was significantly lower than baseline immediately and 48 h after training. Normalized peak torque values were only different between TB and PM at 48 h after training. Considering the small and nonsignificant difference between the recovery of TB and PM muscles, the results suggest that bench press exercise may promote a similar stress on these muscles. Muscle Nerve 56: 963-967, 2017. © 2016 Wiley Periodicals, Inc.
Ghigiarelli, Jamie J; Pelton, Luke M; Gonzalez, Adam M; Fulop, Andras M; Gee, Joshua Y; Sell, Katie M
2018-04-01
Ghigiarelli, JJ, Pelton, LM, Gonzalez, AM, Fulop, AM, Gee, JY, and Sell, KM. Effects of a 6-week bench press program using the freak bar in a sample of collegiate club powerlifters. J Strength Cond Res 32(4): 938-949, 2018-Powerlifters train using specialty bars for unstable load (UL) training. For the bench press, the acute effects of UL are mixed, with few studies that examine training interventions. The purpose of this study was to examine the effects of a 6-week bench press training program that uses the Freak Bar (FB) as compared to a traditional barbell (TB) on maximum bench press, peak force, and peak impulse. Seven men and 3 women (21 ± 2.0 years, 172.2 ± 2.9 cm, and 95.3 ± 20.3 kg) were required to bench press 2 days per week as part of a structured program. On the second bench press day, the FB and TB groups performed 3-position pause bench presses at 60-70% one repetition maximum (1RM). One repetition maximum, peak force, and peak impulse were measured before test and after test after the 6-week program. Peak force and peak impulse were tested at 3 bench positions, including the presticking, sticking, and poststicking points, defined by the distance of the barbell from the chest. Posttraining 1RM for the FB group and TB group increased 6.7% (6.78 ± 1.6 kg, p = 0.006) and 4.3% (4.5 ± 2.7 kg, p = 0.23), respectively, with no significant differences between the groups (p = 0.589, ηp = 0.044). There were no significant differences between the groups at each bench position for peak force (p = 0.606) or peak impulse (p = 0.542). Freak Bar can be an alternative for improving maximum strength and peak force but is not significantly better than TB training when performing the 3-position pause bench press.
Bellar, David M; Muller, Matthew D; Barkley, Jacob E; Kim, Chul-Ho; Ida, Keisuke; Ryan, Edward J; Bliss, Mathew V; Glickman, Ellen L
2011-02-01
The present study investigated the effects of training combining elastic tension, free weights, and the bench press. Eleven college-aged men (untrained) in the bench press participated in the 13-week study. The participants were first given instructions and then practiced the bench press, followed by a one-repetition maximum (1RM) test of baseline strength. Subjects were then trained in the bench press for 3 weeks to allow for the beginning of neural adaptation. After another 1RM test, participants were assigned to 1 of 2 conditions for the next 3 weeks of training: 85% Free-Weight Tension, 15% Elastic Tension (BAND), or 100% Free-Weight Tension (STAND). After 3 weeks of training and a third 1RM max test, participants switched treatments, under which they completed the final 3 weeks of training and the fourth 1RM test. Analysis via analysis of covariance revealed a significant (p ≤ 0.05) main effect for time and interaction effect for Treatment (BAND vs. STAND). Subsequent analysis via paired-samples t-test revealed the BAND condition was significantly better (p = 0.05) at producing raw gains in 1RM strength. (BAND 9.95 ± 3.7 kg vs. STAND 7.56 ± 2.8 kg). These results suggest that the addition of elastic tension to the bench press may be an effective method of increasing strength.
Hot-bench simulation of the active flexible wing wind-tunnel model
NASA Technical Reports Server (NTRS)
Buttrill, Carey S.; Houck, Jacob A.
1990-01-01
Two simulations, one batch and one real-time, of an aeroelastically-scaled wind-tunnel model were developed. The wind-tunnel model was a full-span, free-to-roll model of an advanced fighter concept. The batch simulation was used to generate and verify the real-time simulation and to test candidate control laws prior to implementation. The real-time simulation supported hot-bench testing of a digital controller, which was developed to actively control the elastic deformation of the wind-tunnel model. Time scaling was required for hot-bench testing. The wind-tunnel model, the mathematical models for the simulations, the techniques employed to reduce the hot-bench time-scale factors, and the verification procedures are described.
The objective of this work is to compare the properties of lead solids formed during bench-scale precipitation experiments to solids found on lead pipe removed from real drinking water distribution systems and metal coupons used in pilot scale corrosion testing. Specifically, so...
Simulating wall and corner fire tests on wood products with the OSU room fire model
H. C. Tran
1994-01-01
This work demonstrates the complexity of modeling wall and corner fires in a compartment. The model chosen for this purpose is the Ohio State University (OSU) room fire model. This model was designed to simulate fire growth on walls in a compartment and therefore lends itself to direct comparison with standard room test results. The model input were bench-scale data...
Test bench HEATREC for heat loss measurement on solar receiver tubes
NASA Astrophysics Data System (ADS)
Márquez, José M.; López-Martín, Rafael; Valenzuela, Loreto; Zarza, Eduardo
2016-05-01
In Solar Thermal Electricity (STE) plants the thermal energy of solar radiation is absorbed by solar receiver tubes (HCEs) and it is transferred to a heat transfer fluid. Therefore, heat losses of receiver tubes have a direct influence on STE plants efficiency. A new test bench called HEATREC has been developed by Plataforma Solar de Almería (PSA) in order to determinate the heat losses of receiver tubes under laboratory conditions. The innovation of this test bench consists in the possibility to determine heat losses under controlled vacuum.
Setup of a photomultiplier tube test bench for LHAASO-KM2A
NASA Astrophysics Data System (ADS)
Wang, Xu; Zhang, Zhong-Quan; Tian, Ye; Du, Yan-Yan; Zhao, Xiao; Shen, Fu-Wang; Li, Chang-Yu; Sun, Yan-Sheng; Feng, Cun-Feng
2016-08-01
To fulfill the requirements for testing the photomultiplier tubes (PMTs) of the electromagnetic detector at the Large High Altitude Air Shower Observatory (LHAASO), a multi-functional PMT test bench with a two-dimensional scanning system has been developed. With this 2D scanning system, 16 PMTs can be scanned simultaneously for characteristics tests, including uniformity, cathode transit time difference, single photo-electron spectrum, gain vs. high voltage, linear behavior and dark noise. The programmable hardware and intelligent software of the test bench make it convenient to use and provide reliable results. The test methods are described in detail and primary results are presented. Supported by NSFC (11075096) SDNFS (ZR2011AM007), China
Integrated low emissions cleanup system for direct coal-fueled turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lippert, T.E.; Newby, R.A.; Alvin, M.A.
1992-01-01
The Westinghouse Electric Corporation, Science Technology Center (W-STC) is developing an Integrated Low Emissions Cleanup (ILEC) concept for high-temperature gas cleaning to meet environmental standards, as well as to economical gas turbine life. The ILEC concept simultaneously controls sulfur, particulate, and alkali contaminants in high-pressure fuel gases or combustion gases at temperatures up to 1850[degrees]F for advanced power generation systems (PFBC, APFBC, IGCC, DCF7). The objective of this program is to demonstrate, at a bench scale, the conceptual, technical feasibility of the REC concept. The ELEC development program has a 3 phase structure: Phase 1 - laboratory-scale testing; phase 2more » - bench-scale equipment; design and fabrication; and phase 3 - bench-scale testing. Phase 1 laboratory testing has been completed. In Phase 1, entrained sulfur and alkali sorbent kinetics were measured and evaluated, and commercial-scale performance was projected. Related cold flow model testing has shown that gas-particle contacting within the ceramic barrier filter vessel will provide a good reactor environment. The Phase 1 test results and the commercial evaluation conducted in the Phase 1 program support the bench-scale facility testing to be performed in Phase 3. Phase 2 is nearing completion with the design and assembly of a modified, bench-scale test facility to demonstrate the technical feasibility of the ILEC features. This feasibility testing will be conducted in Phase 3.« less
Integrated low emissions cleanup system for direct coal-fueled turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lippert, T.E.; Newby, R.A.; Alvin, M.A.
1992-12-31
The Westinghouse Electric Corporation, Science & Technology Center (W-STC) is developing an Integrated Low Emissions Cleanup (ILEC) concept for high-temperature gas cleaning to meet environmental standards, as well as to economical gas turbine life. The ILEC concept simultaneously controls sulfur, particulate, and alkali contaminants in high-pressure fuel gases or combustion gases at temperatures up to 1850{degrees}F for advanced power generation systems (PFBC, APFBC, IGCC, DCF7). The objective of this program is to demonstrate, at a bench scale, the conceptual, technical feasibility of the REC concept. The ELEC development program has a 3 phase structure: Phase 1 - laboratory-scale testing; phasemore » 2 - bench-scale equipment; design and fabrication; and phase 3 - bench-scale testing. Phase 1 laboratory testing has been completed. In Phase 1, entrained sulfur and alkali sorbent kinetics were measured and evaluated, and commercial-scale performance was projected. Related cold flow model testing has shown that gas-particle contacting within the ceramic barrier filter vessel will provide a good reactor environment. The Phase 1 test results and the commercial evaluation conducted in the Phase 1 program support the bench-scale facility testing to be performed in Phase 3. Phase 2 is nearing completion with the design and assembly of a modified, bench-scale test facility to demonstrate the technical feasibility of the ILEC features. This feasibility testing will be conducted in Phase 3.« less
Bartolomei, Sandro; Nigro, Federico; Ruggeri, Sandro; Lanzoni, Ivan Malagoli; Ciacci, Simone; Merni, Franco; Sadres, Eliahu; Hoffman, Jay R; Semprini, Gabriele
2018-03-06
The purpose of the present study was to validate the ballistic push-up test performed with hands on a force plate (BPU) as a method to measure upper-body power. Twenty-eight experienced resistance trained men (age = 25.4 ± 5.2 y; body mass = 78.5 ± 9.0 kg; body height = 179.6 ± 7.8 cm) performed, two days apart, a bench press 1RM test and upper-body power tests. Mean power and peak power were assessed using the bench press throw test (BT) and the BPU test performed in randomized order. The area under the force/power curve (AUC) obtained at BT was also calculated. Power expressed at BPU was estimated using a time-based prediction equation. Mean force and the participant's body weight were used to predict the bench press 1RM. Pearson product moment correlations were used to examine relationships between the power assessment methods and between the predicted 1RM bench and the actual value. Large correlations (0.79; p < 0.001) were found between AUC and mean power expressed at BPU. Large correlations were also detected between mean power and peak power expressed at BT and BPU (0.75; p < 0.001 and 0.74; p < 0.001, respectively). Very large correlations (0.87; p < 0.001) were found between the 1RM bench and the 1RM predicted by the BPU. Results of the present study indicate that BPU represents a valid and reliable method to estimate the upper-body power in resistance-trained individuals.
W5″ Test: A simple method for measuring mean power output in the bench press exercise.
Tous-Fajardo, Julio; Moras, Gerard; Rodríguez-Jiménez, Sergio; Gonzalo-Skok, Oliver; Busquets, Albert; Mujika, Iñigo
2016-11-01
The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5″ Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty trained young men completed as many repetitions as possible in a time of ≈5 s at 25%, 45%, 65% and 85% of one-repetition maximum (1RM) in two test sessions separated by four days. The number of repetitions, linear displacement of the bar and time needed to complete the test were recorded by two independent testers, and a linear encoder was used as the criterion measure. For each load, the mean power output was calculated in the W5″ Test as mechanical work per time unit and compared with that obtained from the linear encoder. Subsequently, 20 additional subjects (10 training group vs. 10 control group) were assessed before and after completing a seven-week training programme designed to improve maximal power. Results showed that both assessment methods correlated highly in estimating mean power output at different loads (r range: 0.86-0.94; p < .01) and detecting training-induced changes (R(2): 0.78). Good to excellent intra-tester (intraclass correlation coefficient (ICC) range: 0.81-0.97) and excellent inter-tester (ICC range: 0.96-0.99; coefficient of variation range: 2.4-4.1%) reliability was found for all loads. The W5″ Test was shown to be a valid, reliable and sensitive method for measuring mean power output during the bench press exercise in subjects who have previous resistance training experience.
122. BENCH SHOP, SOUTHWEST CORNER SHOWING WOOD BORING MACHINE. DOOR ...
122. BENCH SHOP, SOUTHWEST CORNER SHOWING WOOD BORING MACHINE. DOOR TO WOODSHOP ON RIGHT. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
ERIC Educational Resources Information Center
Brown, Elizabeth R.; Smith, Jessi L.; Thoman, Dustin B.; Allen, Jill M.; Muragishi, Gregg
2015-01-01
Motivating students to pursue science careers is a top priority among many science educators. We add to the growing literature by examining the impact of a utility value intervention to enhance student's perceptions that biomedical science affords important utility work values. Using an expectancy-value perspective, we identified and tested 2…
Clark, Ross A; Humphries, Brendan; Hohmann, Erik; Bryant, Adam L
2011-03-01
Resistance training programs that emphasize high force production in different regions of the range of motion (ROM) may provide performance benefits. This study examined whether variable ROM (VROM) training, which consists of partial ROM training with countermovements performed in a different phase of the ROM for each set, results in improved functional performance. Twenty-two athletes (age 22.7 ± 2.4 years, height 1.81 ± 0.07 m, and body mass 94.6 ± 14.5 kg) with extensive resistance training backgrounds performed either a VROM or full ROM control (CON) 5-week, concentric work-matched training program. The participants were assigned to a group based on stratified randomization incorporating their strength levels and performance gains in preceding training microcycles. Testing consisted of assessing the force-ROM relationship during isokinetic and isometric bench press and ballistic bench throws, with normalized electromyography amplitude assessed during the isometric tests. Repeated-measure analyses of variance revealed that the VROM intervention significantly (p < 0.05) increased both full ROM bench throw displacement (+15.5%) and half ROM bench throw peak force (+15.7%), in addition to isokinetic peak force in the terminal ROM (13.5% increase). No significant differences were observed in the CON group or between groups for any other outcome measures. Analysis of the force-ROM relationship revealed that that the VROM intervention enhanced performance at shorter muscle lengths. These findings suggest that VROM training improves terminal and midrange performance gains, resulting in the athlete possessing an improved ability to control external loading and produce dynamic force.
118. BENCH SHOP, NORTHWEST CORNER SHOWING ENTRANCE TO ROOM FROM ...
118. BENCH SHOP, NORTHWEST CORNER SHOWING ENTRANCE TO ROOM FROM OUTSIDE. OFFICE SAFE AT CENTER. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
123. BENCH SHOP, SOUTH WALL SHOWING TOOL SHARPENER ON LEFT ...
123. BENCH SHOP, SOUTH WALL SHOWING TOOL SHARPENER ON LEFT AND WOOD BORING MACHINE ON RIGHT. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press.
Lockie, Robert G; Callaghan, Samuel J; Moreno, Matthew R; Risso, Fabrice G; Liu, Tricia M; Stage, Alyssa A; Birmingham-Babauta, Samantha A; Stokes, John J; Giuliano, Dominic V; Lazar, Adrina; Davis, DeShaun L; Orjalo, Ashley J
2017-12-01
The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM) traditional bench press (TBP) and close-grip bench press (CGBP). Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p < 0.05) compared the 1RM and mechanical variables for the TBP and CGBP; effect sizes (d) were also calculated. Pearson's correlations (r; p < 0.05) computed relationships between the TBP and CGBP. 1RM, lift duration, and mean force were greater in the TBP (d = 0.30-3.20). Peak power and velocity was greater for the CGBP (d = 0.50-1.29). The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982). TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931). TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704). TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980). Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.
Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press
Callaghan, Samuel J.; Moreno, Matthew R.; Risso, Fabrice G.; Liu, Tricia M.; Stage, Alyssa A.; Birmingham-Babauta, Samantha A.; Stokes, John J.; Giuliano, Dominic V.; Lazar, Adrina; Davis, DeShaun L.; Orjalo, Ashley J.
2017-01-01
Abstract The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM) traditional bench press (TBP) and close-grip bench press (CGBP). Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p < 0.05) compared the 1RM and mechanical variables for the TBP and CGBP; effect sizes (d) were also calculated. Pearson’s correlations (r; p < 0.05) computed relationships between the TBP and CGBP. 1RM, lift duration, and mean force were greater in the TBP (d = 0.30-3.20). Peak power and velocity was greater for the CGBP (d = 0.50-1.29). The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982). TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931). TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704). TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980). Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements. PMID:29339982
Bench Test Evaluation of Adaptive Servoventilation Devices for Sleep Apnea Treatment
Zhu, Kaixian; Kharboutly, Haissam; Ma, Jianting; Bouzit, Mourad; Escourrou, Pierre
2013-01-01
Rationale: Adaptive servoventilation devices are marketed to overcome sleep disordered breathing with apneas and hypopneas of both central and obstructive mechanisms often experienced by patients with chronic heart failure. The clinical efficacy of these devices is still questioned. Study Objectives: This study challenged the detection and treatment capabilities of the three commercially available adaptive servoventilation devices in response to sleep disordered breathing events reproduced on an innovative bench test. Methods: The bench test consisted of a computer-controlled piston and a Starling resistor. The three devices were subjected to a flow sequence composed of central and obstructive apneas and hypopneas including Cheyne-Stokes respiration derived from a patient. The responses of the devices were separately evaluated with the maximum and the clinical settings (titrated expiratory positive airway pressure), and the detected events were compared to the bench-scored values. Results: The three devices responded similarly to central events, by increasing pressure support to raise airflow. All central apneas were eliminated, whereas hypopneas remained. The three devices responded differently to the obstructive events with the maximum settings. These obstructive events could be normalized with clinical settings. The residual events of all the devices were scored lower than bench test values with the maximum settings, but were in agreement with the clinical settings. However, their mechanisms were misclassified. Conclusion: The tested devices reacted as expected to the disordered breathing events, but not sufficiently to normalize the breathing flow. The device-scored results should be used with caution to judge efficacy, as their validity depends upon the initial settings. Citation: Zhu K; Kharboutly H; Ma J; Bouzit M; Escourrou P. Bench test evaluation of adaptive servoventilation devices for sleep apnea treatment. J Clin Sleep Med 2013;9(9):861-871. PMID:23997698
NanoBench: An Individually Addressable Nanotube Array
2006-03-25
17 (1999). 5 Cai, L., H. Tabata and T. Kawai, "Probing electrical properties of oriented DNA by conducting atomic force microscopy", Nanotechnology 12...the e-beam hits the other side of the NanoBench. This allows the cells to be kept alive in a biological medium while they are being tested. The key...advantage of the NanoBench is that the e-beam never hits the sample. UHV Technologies Inc. 7 NanoBench: An Individually Addressable Nanotube Array Final
Code of Federal Regulations, 2014 CFR
2014-10-01
... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2014-10-01 2014-10-01 false Dust, fume, mist, and smoke tests; canister bench...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2013-10-01 2013-10-01 false Dust, fume, mist, and smoke tests; canister bench...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2010-10-01 2010-10-01 false Dust, fume, mist, and smoke tests; canister bench...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2011-10-01 2011-10-01 false Dust, fume, mist, and smoke tests; canister bench...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2012-10-01 2012-10-01 false Dust, fume, mist, and smoke tests; canister bench...
Measure Twice, Build Once: Bench-Scale Testing to Evaluate Bioretention Media Design - slides
The oral presentation will be at the EWRI International LID Conference in San Francisco, on April 11-14, 2010. The slides discuss the utility of conducting bench-scale testing on selected bioretention media and media amendments to validate hydrologic properties before installing...
Genifuel Hydrothermal Processing Bench Scale Technology Evaluation Project (WE&RF Report LIFT6T14)
Hydrothermal Liquefaction (HTL) and Catalytic Hydrothermal Gasification (CHG) proof-of-concept bench-scale tests were performed to assess the potential of the Genifuel hydrothermal process technology for handling municipal wastewater sludge. HTL tests were conducted at 300-350◦C ...
A Method to Estimate Fabric Particle Penetration Performance
2014-09-08
may be needed to improve the correlation between wind tunnel component sleeve tests and bench top swatch test. The ability to predict multi-layered...within the fabric/component gap may be needed to improve the correlation between wind tunnel component sleeve tests and bench top swatch test...impermeable garment . Heat stress becomes a major problem with this approach however, as normal physiological heat loss mechanisms (especially sweat
Calibration of the MCAO Canopus Bench
NASA Astrophysics Data System (ADS)
Garcia-Rissmann, Aurea; Rigaut, François; Bec, Matthieu; Boccas, Maxime; Galvez, Ramon; Gausachs, Gaston; Gratadour, Damien; Neichel, Benoit
The final phase of implementation of all optical components, as well as their integration and tests on the Canopus MCAO bench is currently underway. We present here a detailed description of the LGS and NGS WFS calibration sequences implemented through MYST (MCAO Yorick Smart Tool), a yorick+python+glade software package developed in-house which allows multiple users to control and monitor the bench remotely over the network using EPICS commands. A fine tuning of the optical setup and a better understanding of the flexure/temperature dependencies is being carried out and will allow us to build the many look-up tables to be eventually used by the system (e.g. telescope primary and secondary mirrors). Preliminary work on non-common path aberrations to account for the static aberrations in the central 60 arcsec science field of view (FoV) has been done iteratively using a science focal plane wavefront sensor and has shown good results both in individual directions as well as simultaneously over the entire FoV, the latter using the tomographic approach (presented in another paper in this conference).
Effect of bench time polymerization on depth of cure of dental composite resin
NASA Astrophysics Data System (ADS)
Harahap, K.; Yudhit, A.; Sari, F.
2017-07-01
The aim of this research was to investigate the effect of bench time before light cured polymerization on the depth of cure of dental composite resin. Nanofiller composite resin (Filtek Z350 XT,3M, ESPE,China) was used in this study. Sixty samples of nanofiller composite resin were made and divided into control and test groups with bench time for 0, 15, 30, 45, and 60 min. For the test group, composite resins were stored in refrigerator with 4°C temperatures. Meanwhile, for the control groups, the composite resin was stored at room temperature. The samples were prepared using metal mould with size diameter of 6 mm and 4 mm in thickness. Samples were cured for 20 s by using visible blue light curing unit. Part of samples that unpolymerized were removed by using a plastic spatula. The remaining parts of samples were measured by digital caliper and noted as depth of cure (mm). Data were analyzed to one-way ANOVA and LSD tests (p≤0.05). Results showed there was no significance differences between test groups (p=0.5). A 60 minutes bench time group showed the highest depth of cure value among test group, and it was almost similar with control group value. It can be concluded that longer bench time can increase the depth of cure of composite resin.
24. July 1974. BENCH SHOP, VIEW OF THE SOUTHEAST CORNER. ...
24. July 1974. BENCH SHOP, VIEW OF THE SOUTHEAST CORNER. NOTE VARIOUS METHODS OF STORING TOOLS AND THE ELECTRICAL SYSTEM. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
125. BENCH SHOP, LOOKING SOUTHEAST AT CENTER OF ROOM SHOWING ...
125. BENCH SHOP, LOOKING SOUTHEAST AT CENTER OF ROOM SHOWING TOOL SHARPENER ON RIGHT AND ELECTRIC TABLE SAW AT CENTER. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
22. August 1974. BENCH SHOP, EAST WALL VIEW SHOWING HINGED ...
22. August 1974. BENCH SHOP, EAST WALL VIEW SHOWING HINGED PANEL AND WHEELPIT FOR MOUNTING SPOKES IN WHEEL HUB. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
A white super-stable source for the metrology of astronomical photometers
NASA Astrophysics Data System (ADS)
Wildi, F. P.; Deline, A.; Chazelas, B.
2015-09-01
The testing of photometers and in particular the testing of high precision photometers for the detection of planetary transits requires a light source which photometric stability is to par or better than the goal stability of the photometer to be tested. In the frame of the CHEOPS mission, a comprehensive calibration bench has been developed. Aside from measuring the sensibility of the CHEOPS payload to the different environmental conditions, this bench will also be used to test the relative accuracy of the payload. A key element of this bench is an extremely stable light source that is used to create an artificial star which is then projected into the payload's telescope. We present here the development of this payload and the performance achieved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lail, Marty
The project aimed to advance RTI’s non-aqueous amine solvent technology by improving the solvent to reduce volatility, demonstrating long-term continuous operation at lab- (0.5 liters solvent) and bench-scale (~120 liters solvent), showing low reboiler heat duty measured during bench-scale testing, evaluating degradation products, building a rate-based process model, and evaluating the techno-economic performance of the process. The project team (RTI, SINTEF, Linde Engineering) and the technology performed well in each area of advancement. The modifications incorporated throughout the project enabled the attainment of target absorber and regenerator conditions for the process. Reboiler duties below 2,000 kJt/kg CO2 were observed inmore » a bench-scale test unit operated at RTI.« less
Giancarlo, R; Scaturro, D; Utro, F
2015-02-01
The prediction of the number of clusters in a dataset, in particular microarrays, is a fundamental task in biological data analysis, usually performed via validation measures. Unfortunately, it has received very little attention and in fact there is a growing need for software tools/libraries dedicated to it. Here we present ValWorkBench, a software library consisting of eleven well known validation measures, together with novel heuristic approximations for some of them. The main objective of this paper is to provide the interested researcher with the full software documentation of an open source cluster validation platform having the main features of being easily extendible in a homogeneous way and of offering software components that can be readily re-used. Consequently, the focus of the presentation is on the architecture of the library, since it provides an essential map that can be used to access the full software documentation, which is available at the supplementary material website [1]. The mentioned main features of ValWorkBench are also discussed and exemplified, with emphasis on software abstraction design and re-usability. A comparison with existing cluster validation software libraries, mainly in terms of the mentioned features, is also offered. It suggests that ValWorkBench is a much needed contribution to the microarray software development/algorithm engineering community. For completeness, it is important to mention that previous accurate algorithmic experimental analysis of the relative merits of each of the implemented measures [19,23,25], carried out specifically on microarray data, gives useful insights on the effectiveness of ValWorkBench for cluster validation to researchers in the microarray community interested in its use for the mentioned task. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Judge, Lawrence W; Burke, Jeanmarie R
2010-06-01
To determine the effects of training sessions, involving high-resistance, low-repetition bench press exercise, on strength recovery patterns, as a function of gender and training background. The subjects were 12 athletes (6 males and 6 females) and age-matched college students of both genders (4 males and 4 females). The subjects completed a 3-wk resistance training program involving a bench press exercise, 3 d/wk, to become familiar with the testing procedure. After the completion of the resistance training program, the subjects, on three consecutive weeks, participated in two testing sessions per week, baseline session and recovery session. During the testing sessions, subjects performed five sets of the bench press exercise at 50% to 100% of perceived five repetition maximum (5-RM). Following the weekly baseline sessions, subjects rested during a 4-, 24-, or 48-h recovery period. Strength measurements were estimates of one repetition maximum (1-RM), using equivalent percentages for the number of repetitions completed by the subject at the perceived 5-RM effort of the bench press exercise. The full-factorial ANOVA model revealed a Gender by Recovery Period by Testing Session interaction effect, F(2, 32) = 10.65; P < .05. Among male subjects, decreases in estimated 1-RM were detected at the 4- and 24-h recovery times. There were no differences in muscle strength among the female subjects, regardless of recovery time. For bench press exercises, using different recovery times of 48 h for males and 4 h for females may optimize strength development as a function of gender.
AVHRR/1-FM Advanced Very High Resolution Radiometer
NASA Technical Reports Server (NTRS)
1979-01-01
The advanced very high resolution radiometer is discussed. The program covers design, construction, and test of a breadboard model, engineering model, protoflight model, mechanical/structural model, and a life test model. Special bench test and calibration equipment was developed for use on the program. The flight model program objectives were to fabricate, assemble and test four of the advanced very high resolution radiometers along with a bench cooler and collimator.
Mika, K B; Imamura, G; Chang, C; Conway, V; Fernandez, G; Griffith, J F; Kampalath, R A; Lee, C M; Lin, C-C; Moreno, R; Thompson, S; Whitman, R L; Jay, J A
2009-07-01
Factors affecting faecal indicator bacteria (FIB) and pathogen survival/persistence in sand remain largely unstudied. This work elucidates how biological and physical factors affect die-off in beach sand following sewage spills. Solar disinfection with mechanical mixing was pilot-tested as a disinfection procedure after a large sewage spill in Los Angeles. Effects of solar exposure, mechanical mixing, predation and/or competition, season, and moisture were tested at bench scale. First-order decay constants for Escherichia coli ranged between -0.23 and -1.02 per day, and for enterococci between -0.5 and -1.0 per day. Desiccation was a dominant factor for E. coli but not enterococci inactivation. Effects of season were investigated through a comparison of experimental results from winter, spring, and fall. Moisture was the dominant factor controlling E. coli inactivation kinetics. Initial microbial community and sand temperature were also important factors. Mechanical mixing, common in beach grooming, did not consistently reduce bacterial levels. Inactivation rates are mainly dependent on moisture and high sand temperature. Chlorination was an effective disinfection treatment in sand microcosms inoculated with raw influent.
Electromagnetic interference in electrical systems of motor vehicles
NASA Astrophysics Data System (ADS)
Dziubiński, M.; Drozd, A.; Adamiec, M.; Siemionek, E.
2016-09-01
Electronic ignition system affects the electronic equipment of the vehicle by electric and magnetic fields. The measurement of radio electromagnetic interference originating from the ignition system affecting the audiovisual test bench was carried out with a variable speed of the ignition system. The paper presents measurements of radio electromagnetic interference in automobiles. In order to determine the level of electromagnetic interference, the audiovisual test bench was equipped with a set of meters for power consumption and assessment of the level of electromagnetic interference. Measurements of the electromagnetic interference level within the audiovisual system were performed on an experimental test bench consisting of the ignition system, starting system and charging system with an alternator and regulator.
Bench Test of the Vibration Compensation Interferometer for EAST Tokamak
NASA Astrophysics Data System (ADS)
Li, Gongshun; Yang, Yao; Liu, Haiqing; Jie, Yinxian; Zou, Zhiyong; Wang, Zhengxing; Zeng, Long; Wei, Xuechao; Li, Weiming; Lan, Ting; Zhu, Xiang; Liu, Yukai; Gao, Xiang
2016-02-01
A visible laser-based vibration compensation interferometer has recently been designed for the EAST tokamak and the bench test has been finished. The system was optimized for its installation on EAST. The value of the final optical power before the detectors without plasma has been calculated from the component bench test result, which is quite close to the measured value. A nanometer level displacement (of the order of the laser's wavelength) has been clearly measured by a modulation of piezoelectric ceramic unit, proving the system's capability. supported by the National Magnetic Confinement Fusion Program of China (Nos. 2014GB106002, 2014GB106003, 2014GB106004) and National Natural Science Foundation of China (Nos. 11105184, 11375237, 11505238)
REVIEW OF BENCH-, PILOT-, AND FULL-SCALE ORIMULSION (R) COMBUSTION TESTS
The paper gives results of a review of bench-, pilot-, and full-scale Orimulsion combustion tests. A fossil fuel marketed by its producer, Petroleos de Venezuela, S.A. (PdVSA), since the late 1980s as an alternative to coal and heavy fuel oil, Orimulsion is a bitumen-in-water em...
Orbit attitude processor. STS-1 bench program verification test plan
NASA Technical Reports Server (NTRS)
Mcclain, C. R.
1980-01-01
A plan for the static verification of the STS-1 ATT PROC ORBIT software requirements is presented. The orbit version of the SAPIENS bench program is used to generate the verification data. A brief discussion of the simulation software and flight software modules is presented along with a description of the test cases.
DATA QUALITY OBJECTIVES FOR SELECTING WASTE SAMPLES FOR BENCH-SCALE REFORMER TREATABILITY STUDIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
BANNING DL
2011-02-11
This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Bench-Scale Reforming testing. The type, quantity, and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluidized bed steam reformer. A determination of the adequacy of the fluidized bed steam reformer process to treat Hanford tank waste is required.more » The initial step in determining the adequacy of the fluidized bed steam reformer process is to select archived waste samples from the 222-S Laboratory that will be used in a bench scale tests. Analyses of the selected samples will be required to confirm the samples meet the shipping requirements and for comparison to the bench scale reformer (BSR) test sample selection requirements.« less
Evaluation of roll designs on a roll-crusher/ crusher/splitter biomass harvester: test bench results
Colin Ashmore; Donald L. Sirois; Bryce J. Stokes
1987-01-01
Four different roll designs were evaluated on a test bench roll crusher/splitter to determine feeding and crushing efficiencies. For each design, different gap settings for the primary and secondary rolls were tested at two hydraulic cylinder pressures on the primary crush roll to determine their ability to crush and/or feed tree bolts. Seven different diameter classes...
Validity of the Myotest® in measuring force and power production in the squat and bench press.
Comstock, Brett A; Solomon-Hill, Glenn; Flanagan, Shawn D; Earp, Jacob E; Luk, Hui-Ying; Dobbins, Kathryn A; Dunn-Lewis, Courtenay; Fragala, Maren S; Ho, Jen-Yu; Hatfield, Disa L; Vingren, Jakob L; Denegar, Craig R; Volek, Jeff S; Kupchak, Brian R; Maresh, Carl M; Kraemer, William J
2011-08-01
The purpose of this study was to verify the concurrent validity of a bar-mounted Myotest® instrument in measuring the force and power production in the squat and bench press exercises when compared to the gold standard of a computerized linear transducer and force platform system. Fifty-four men (bench press: 39-171 kg; squat: 75-221 kg) and 43 women (bench press: 18-80 kg; squat: 30-115 kg) (age range 18-30 years) performed a 1 repetition maximum (1RM) strength test in bench press and squat exercises. Power testing consisted of the jump squat and the bench throw at 30% of each subject's 1RM. During each measurement, both the Myotest® instrument and the Celesco linear transducer of the directly interfaced BMS system (Ballistic Measurement System [BMS] Innervations Inc, Fitness Technology force plate, Skye, South Australia, Australia) were mounted to the weight bar. A strong, positive correlation (r) between the Myotest and BMS systems and a high correlation of determination (R2) was demonstrated for bench throw force (r = 0.95, p < 0.05) (R2 = 0.92); bench throw power (r = 0.96, p < 0.05) (R2 = 0.93); squat jump force (r = 0.98, p < 0.05) (R2 = 0.97); and squat jump power (r = 0.91, p < 0.05) (R2 = 0.82). In conclusion, when fixed on the bar in the vertical axis, the Myotest is a valid field instrument for measuring force and power in commonly used exercise movements.
Bench test evaluation of adaptive servoventilation devices for sleep apnea treatment.
Zhu, Kaixian; Kharboutly, Haissam; Ma, Jianting; Bouzit, Mourad; Escourrou, Pierre
2013-09-15
Adaptive servoventilation devices are marketed to overcome sleep disordered breathing with apneas and hypopneas of both central and obstructive mechanisms often experienced by patients with chronic heart failure. The clinical efficacy of these devices is still questioned. This study challenged the detection and treatment capabilities of the three commercially available adaptive servoventilation devices in response to sleep disordered breathing events reproduced on an innovative bench test. The bench test consisted of a computer-controlled piston and a Starling resistor. The three devices were subjected to a flow sequence composed of central and obstructive apneas and hypopneas including Cheyne-Stokes respiration derived from a patient. The responses of the devices were separately evaluated with the maximum and the clinical settings (titrated expiratory positive airway pressure), and the detected events were compared to the bench-scored values. The three devices responded similarly to central events, by increasing pressure support to raise airflow. All central apneas were eliminated, whereas hypopneas remained. The three devices responded differently to the obstructive events with the maximum settings. These obstructive events could be normalized with clinical settings. The residual events of all the devices were scored lower than bench test values with the maximum settings, but were in agreement with the clinical settings. However, their mechanisms were misclassified. The tested devices reacted as expected to the disordered breathing events, but not sufficiently to normalize the breathing flow. The device-scored results should be used with caution to judge efficacy, as their validity depends upon the initial settings.
Brosnan, Caragh; Cribb, Alan
2014-12-01
This paper presents findings from an empirical study that explored the meaning of ethics in the everyday work of neuroscientists. Observation and interviews were carried out in one neuroscience research group that was involved in bench-to-bedside translational research. We focus here specifically on the scientists' perceptions of bioethics. Interviewees were often unfamiliar with bioethics as a discipline, particularly the more junior members of the group. Those who were aware of its existence largely viewed it as something distant from them, and as either too abstract, not relevant or an alien imposition on their work. Some interviewees themselves pointed to the need for better 'bridge building' between ethical principles and real-world examples drawn from scientific practice, and we argue that this space is where a more empirically grounded ethics may be useful in terms of actually engaging scientists at both the bench and the bedside.
[Soft-ridged bench terrace design in hilly loess region].
Cao, Shixiong; Chen, Li; Gao, Wangsheng
2005-08-01
Reconfiguration of hillside field into terrace is regarded as one of the key techniques for water and soil conservation in mountainous regions. On slopes exceeding 30 degrees, the traditional techniques of terracing are difficult to apply as risers (i.e., backslopes), and if not reinforced, are so abrupt and easy to collapse under gravity alone, thus damaging the terrace. To improve the reconfiguration of hillside field into terrace, holistic techniques of soft-ridged bench terrace engineering, including revegetation, with trees and planting grasses on riser slopes, were tested between 1997 and 2001 in Xiabiangou watershed of Yan' an, Shaanxi Province. A "working with Nature" engineering approach, riser slopes of 45 degrees, similar to the pre-existing slope of 35 degrees, was employed to radically reduce gravity-erosion. Based on the concepts of biodiversity and the principles of landscape ecology, terrace benches, bunds, and risers were planted with trees, shrubs, forage grasses, and crops, serving to generate a diverse array of plants, a semi-forested area, and to stabilize terrace bunds. Soft-ridged bench terrace made it possible to significantly reduce hazards arising from gravity erosion, and reduce the costs of individual bench construction and maintenance by 24.9% and 55.5% of the costs under traditional techniques, respectively. Such a construction allowed an enrichment and concentration of nutrients in the soils of terrace bunds, providing an ideal environment for a range of plants to grow and develop. The terrace riser could be planted with drought-resistant plants ranging from forage grasses to trees, and this riser vegetation would turn the exposed bunds and risers existing under traditional techniques into plant-covered belts, great green ribbons decorating farmland and contributing to the enhancement of the landscape biology.
Comparison between simulations and lab results on the ASSIST test-bench
NASA Astrophysics Data System (ADS)
Le Louarn, Miska; Madec, Pierre-Yves; Kolb, Johann; Paufique, Jerome; Oberti, Sylvain; La Penna, Paolo; Arsenault, Robin
2016-07-01
We present the latest comparison results between laboratory tests carried out on the ASSIST test bench and Octopus end-to end simulations. We simulated, as closely to the lab conditions as possible, the different AOF modes (Maintenance and commissioning mode (SCAO), GRAAL (GLAO in the near IR), Galacsi Wide Field mode (GLAO in the visible) and Galacsi narrow field mode (LTAO in the visible)). We then compared the simulation results to the ones obtained on the lab bench. Several aspects were investigated, like number of corrected modes, turbulence wind speeds, LGS photon flux etc. The agreement between simulations and lab is remarkably good for all investigated parameters, giving great confidence in both simulation tool and performance of the AO system in the lab.
NASA Astrophysics Data System (ADS)
Liu, L.; Ye, X.; Wu, S. C.; Bai, Y. Z.; Zhou, Z. B.
2015-10-01
The performance test of precision space inertial sensors on the ground is inevitably affected by seismic noise. A traditional vibration isolation platform, generally with a resonance frequency of several Hz, cannot satisfy the requirements for testing an inertial sensor at low frequencies. In this paper, we present a pendulum bench for inertial sensor testing based on translation-tilt compensation. A theoretical analysis indicates that the seismic noise effect on inertial sensors located on this bench can be attenuated by more than 40 dB below 0.1 Hz, which is very significant for investigating the performance of high-precision inertial sensors. We demonstrate this attenuation with a dedicated experiment.
Verbal messages strengthen bench press efficacy.
Wise, James B; Posner, Amy E; Walker, Gretchen L
2004-02-01
This study examined the effects of verbal messages on bench press efficacy: the confidence to lift progressively heavier weights for 1 repetition. Thirty-two women who had not bench pressed within the previous 18 months were assigned to 1 of 2 groups and exposed to 2 sources of efficacy information. First, subjects in both groups performed 10 repetitions on a fixed movement, vertical bench press machine and completed the bench press efficacy scale. Next, each group received 1 of 2 possible verbal messages. Both messages included the speaker's strength training qualifications. In addition, one message conveyed specific performance feedback while the other contained more general information. Then efficacy was measured again. Results indicated both messages strengthened efficacy. Strength professionals who work one-on-one with novice women should: (a) make sure lifters are aware of their professional qualifications, (b) provide specific feedback, and (c) profess their beliefs in the lifters' abilities to perform the exercises.
Improvement of bench life-tests for automotive batteries
NASA Astrophysics Data System (ADS)
Richter, G.
A common method for rating the endurance of automotive batteries is the bench life-test according to DIN, IEC, SAE or JIS. With an increasing number of maintenance-free batteries on the market, the application of these tests becomes more problematic. This is due to a step-by-step capacity decline during cycling if the content of autimony in the grid-alloy is decreased. The degradation in performance is caused by the phenomenon of acid stratification. Because this debilitating effect occurs only rarely in service (vehicle movement) if charging and discharging is well balanced, there is a need for a new bench life-test with conditions that are more representative of practical conditions. Research has shown that the main changes should be: (i) an accelerated (moved) battery during cycling; (ii) slightly lower charging or discharging capacity amplitude, also with a lower mean value.
NASA Astrophysics Data System (ADS)
Leviton, Douglas B.; Frey, Brad J.; Madison, Larry E.; Parker, James A.; Sheinman, Oren E.
2003-03-01
The Swift optical bench is a roughly 2.7 m diameter, 0.1 m thick composite structure carrying the Burst Alert Telescope (BAT), X-ray Telescope (XRT), and the Ultraviolet Optical Telescope (UVOT) as well as various attitude control instrumentation for the spacecraft. A high precision test of the optical bench using multi-aperture optical deflectometry was developed to verify that the relative boresights of the XRT and UVOT instruments would not change by more than several arcseconds when a worst case on-orbit temperature gradient is imposed through the thickness of the bench. Results of validation tests in a laminar flow cleanroom environment without vibration isolation demonstrated a differential measurement capability with 0.2 arcsecond sensitivity and 0.5 arcsecond accuracy per day. The technique is easily adaptable to similar deflection monitoring requirements for other large spacecraft structures.
Cotterman, Michael L; Darby, Lynn A; Skelly, William A
2005-02-01
The Smith machine (SM) (vertical motion of bar on fixed path; fixed-form exercise) and free weights (FWs) (free-form path) are commonly used strength training modes. Exercisers may need to alternate between types of equipment, depending on testing, training, rehabilitation, and/or the exercisers' goals. The purposes of this study were to compare muscle force production for SM and FWs using a 1 repetition maximum (1RM) for the parallel back squat and supine bench press exercises and to predict the 1RM for one mode from 1RM on the other mode. Men (n = 16) and women (n = 16) alternately completed 1RM testing for squat and bench press using SM and FWs. Analyses of variance (type of equipment x sex) and linear regression models were calculated. A significant difference was found between bench press and squat 1RMs for each mode of equipment for all participants. The squat 1RM was greater for the SM than the FWs; conversely, the bench 1RM was greater for FWs than the SM. When sex was considered, bench 1RM for FWs was greater than SM for men and women. The squat 1RM was greater for SM than FWs for women only. The 1RM on one mode of equipment was the best predictor of 1RM for the other mode. For both sexes, the equation SM bench 1RM (in kilograms) = -6.76 + 0.95 (FW bench 1RM) can be used. For women only, SM squat 1RM (in kilograms) = 28.3 + 0.73 (FW squat 1RM). These findings provide equations for converting between SM and FW equipment for training.
Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain
2015-12-01
Display (LCD) Screen Thermal Testing to Simulate Solar Gain 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6 . AUTHOR(S) Steven...Sunlight, Monitor Screen Covered 9 2.6 Test 6 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass 9 2.7 Test 7 – Bench Test with a 250 W Heat...that was used. The use of a black background with white text was important in creating the worst-case scenario for the absorption of solar radiation
Stretch shorten cycle performance enhancement through flexibility training.
Wilson, G J; Elliott, B C; Wood, G A
1992-01-01
Sixteen experienced male powerlifters served as subjects in a training study designed to examine the effect of flexibility training on: (i) the stiffness of the series elastic components (SEC) of the upper body musculature and (ii) rebound and purely concentric bench press performance. Nine of the subjects participated in two sessions of flexibility training twice per week for 8 wk. Prior to and after the training period the subjects' static flexibility, SEC stiffness, rebound bench press (RBP), and purely concentric bench press (PCBP) performance were recorded. The flexibility training induced a significant reduction in the maximal stiffness of the SEC. Furthermore, the experimental subjects produced significantly more work during the initial concentric portion of the RBP lift, enabling a significantly greater load to be lifted in the post-training testing occasion. The benefits to performance achieved by the experimental group consequent to flexibility training were greater during the RBP lift as compared with the PCBP lift. The control subjects exhibited no change in any variable over the training period. These results implied that the RBP performance enhancement observed consequent to flexibility training was directly caused by a reduction in SEC stiffness, increasing the utilization of elastic strain energy during the RBP lift.
NASA Technical Reports Server (NTRS)
1980-01-01
The design and development of an advanced Czochralski crystal grower are described. Several exhaust gas analysis system equipment specifications studied are discussed. Process control requirements were defined and design work began on the melt temperature, melt level, and continuous diameter control. Sensor development included assembly and testing of a bench prototype of a diameter scanner system.
Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory
NASA Astrophysics Data System (ADS)
Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.
2018-01-01
A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot cell 2 of STAR facility for final qualification tests. PWR rod punctures are already planned for 2018.
Passive Thermal Compensation of the Optical Bench of the Galaxy Evolution Explorer
NASA Technical Reports Server (NTRS)
Ford, Virginia; Parks, Rick; Coleman, Michelle
2004-01-01
The Galaxy Evolution Explorer is an orbiting space telescope that will collect information on star formation by observing galaxies and stars in ultraviolet wavelengths. The optical bench supporting detectors and related optical components used an interesting and unusual passive thermal compensation technique to accommodate thermally-induced focal length changes in the optical system. The proposed paper will describe the optical bench thermal compensation design including concept, analysis, assembly and testing results.
Coal Technology Program progress report, March 1976
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Shakedown tests of the bench-scale hydrocarbonization system were successfully completed. Wyodak coal was fed to the reactor at a rate of 9.9 lb/hr where it was hydrocarbonized at 1050/sup 0/F under 20-atm hydrogen pressure. Laboratory results including settling tests, bench-scale settling tests, and sample ageing tests were continued. Two of ten compounds tested with the laboratory-scale apparatus were effective in increasing settling rates of solids in Solvent Refined Coal unfiltered oil, but bench-scale tests failed to show any improvements in the settling rate over the untreated SRC-UFO. Analytical chemistry efforts involved the removal and concentration of organic components in by-productmore » waters from fossil fuel conversion processes. A sephadex gel is being used to achieve hydrophilic-lipophilic separations in organic mixtures as a step in the analysis of fossil fuel related materials. Engineering Evaluations of the Synthiol and Hydrocarbonization Processes continued with the Synthiol process flow diagrams, heat and material balances, and utilities requirements being completed. Inspection techniques were developed for wear- and process-resistant coatings. Orders were placed for the Incoloy 800 tubing and a smaller quantity of Inconel 600 tubing for the tube matrix in the coal-fueled MIUS fluidized bed. An engineering feasibility review of General Atomic's proposal to ERDA for a bench-scale test program on thermochemical water splitting for hydrogen production was completed. (auth)« less
The National Football League-225 Bench Press Test and the Size-Weight Illusion.
Luebbers, Paul E; Buckingham, Gavin; Butler, Michael S
2017-06-01
The purpose of this study was to test reports that size and arrangement manipulations of weight plates (i.e., inducing a size-weight illusion [SWI]) effect athletic weightlifting performance. The participants were 72 experienced, weight-trained collegiate American football players. Across three weeks, each athlete performed three different repetitions-to-fatigue bench press tests (NFL-225, SWI-225, and SWI-215). A multiple regression revealed a positive association between participants' strength relative to the test load and repetitions for NFL-225 and SWI-215, but no association with SWI-225. To explore these results, players were ranked into quartiles based on their one-repetition maximum relative to 102.27 kg (225 lb), and a 3 × 4 repeated measures analysis of variance was conducted. The primary finding was a significant Test Condition × Quartile interaction ( p = .004). Bonferroni-corrected pairwise comparisons revealed that Quartile 4 (those with lowest strength relative to test load) completed more repetitions for SWI-225 compared with NFL-225 ( p = .049). These results suggest that alternate weight plate arrangements may be beneficial for those whose bench press load is near the lifter's one-repetition maximum. However, variations of the SWI do not appear to affect the performance of repetitions-to-fatigue bench press tests for the majority of collegiate American football players.
Mann, J Bryan; Ivey, Pat A; Stoner, Josh D; Mayhew, Jerry L; Brechue, William F
2015-11-01
Numerous investigations have attested to the efficacy of the National Football League (NFL)-225 test to estimate one repetition maximum (1RM) bench press. However, no studies have assessed the efficacy of the test to track changes in strength across a training program. The purpose of this study was to determine the accuracy of the NFL-225 test for determining the change in 1RM bench press in National Collegiate Athletic Association Division IA college football players after training. Over a 4-year period, players (n = 203) were assessed before and after a 6-week off-season resistance program for 1RM bench press and repetitions completed with 102.3 kg (225 lbs). Test sessions typically occurred within 1 week of each other. Players significantly increased 1RM by 4.2 ± 8.6 kg and NFL-225 repetitions by 0.9 ± 2.3, although the effect size (ES) for each was trivial (ES = 0.03 and 0.07, respectively). National Football League 225 prediction equations had higher correlations with 1RM before training (intraclass correlation coefficient [ICC] = 0.95) than after training (ICC = 0.75). The correlation between the change in NFL-225 repetitions and change in 1RM was low and negative (r = -0.22, p < 0.02). Short-term heavy resistance training may alter the association between muscular strength and muscular endurance in college football players and render the NFL-225 test less effective in predicting the change in 1RM bench press strength after short-term training.
NASA Technical Reports Server (NTRS)
Mathews, Charles W.; Kleckner, Harold F.
1947-01-01
The NACA is conducting a general investigation of servo-mechanisms for use in powering aircraft control surfaces. This paper presents a theoretical analysis and the results of bench tests of a control-booster system which employs a variable displacement hydraulic pump. The booster is intended for use in a flight investigation to determine the effects of various booster parameters on the handling qualities of airplanes. Such a flight investigation would aid in formulating specific requirements concerning the design of control boosters in general. Results of the theoretical analysis and the bench tests indicate that the subject booster is representative of types which show promise of satisfactory performance. The bench tests showed that the following desirable features were inherent in this booster system: (1) No lost motion or play in any part of the system; (2) no detectable lag between motion of the contra1 stick and control surface; and (3) Good agreement between control displacements and stick-force variations with no hysteresis in the stick-force characteristics. The final design configuration of this booster system showed no tendency to oscillate, overshoot, or have other undesirable transient characteristics common to boosters.
Saccomandi, Paola; Varalda, Ambra; Gassino, Riccardo; Tosi, Daniele; Massaroni, Carlo; Caponero, Michele A; Pop, Raoul; Korganbayev, Sanzhar; Perrone, Guido; Diana, Michele; Vallan, Alberto; Costamagna, Guido; Marescaux, Jacques; Schena, Emiliano
2017-09-01
The response of a fiber optic sensor [linearly chirped fiber Bragg grating (LCFBG)] to a linear thermal gradient applied on its sensing length (i.e., 1.5 cm) has been investigated. After these bench tests, we assessed their feasibility for temperature monitoring during thermal tumor treatment. In particular, we performed experiments during ex vivo laser ablation (LA) in pig liver and in vivo thermal ablation in animal models (pigs). We investigated the following: (i) the relationship between the full width at half maximum of the LCFBG spectrum and the temperature difference among the extremities of the LCFBG and (ii) the relationship between the mean spectrum wavelength and the mean temperature acting on the LCFBG sensing area. These relationships showed a linear trend during both bench tests and LA in animal models. Thermal sensitivity was significant although different values were found with regards to bench tests and animal experiments. The linear trend and significant sensitivity allow hypothesizing a future use of this kind of sensor to monitor both temperature gradient and mean temperature within a tissue undergoing thermal treatment. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Rogers, Benjamin H.; Brown, Justin C.; Gater, David R.; Schmitz, Kathryn H.
2016-01-01
Objective One-repetition maximum (1-RM) bench press strength is considered the gold standard to quantify upper-body muscular strength. Isometric handgrip strength is frequently used as a surrogate for 1-RM bench press strength among breast cancer (BrCa) survivors. The relationship between 1-RM bench press strength and isometric handgrip strength, however, has not been characterized among BrCa survivors. Design Cross-sectional study. Setting Laboratory. Participants Community-dwelling BrCa survivors. Interventions Not applicable. Main Outcome Measure 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer with three maximal contractions of left and right hands. All measures were conducted by staff with training in clinical exercise testing. Results Among 295 BrCa survivors, 1-RM bench press strength was 18.2±6.1 kg (range: 2.2-43.0) and isometric handgrip strength was 23.5±5.8 kg (range: 9.0-43.0). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=0.399; P<0.0001). Mean-difference analysis suggested that the average isometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7 kg (95% limits of agreement: −8.2 to 17.6). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=0.31; P<0.0001) and age (β=−0.20; P<0.0001) were positively correlated with 1-RM bench press strength (R2=0.23). Conclusions Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among BrCa survivors. 1-RM bench press and isometric handgrip strength quantify distinct components of muscular strength. PMID:27543047
Relationship of pectoralis major muscle size with bench press and bench throw performances.
Akagi, Ryota; Tohdoh, Yukihiro; Hirayama, Kuniaki; Kobayashi, Yuji
2014-06-01
This study examined the relationship of muscle size indices of the pectoralis major muscle with bench press and bench throw performances in 18 male collegiate athletes. The maximal cross-sectional area (MCSAMAx) and volume (MV) of the pectoralis major muscle were determined by magnetic resonance imaging. First, subjects were tested for their one repetition maximum bench press strength (1RMBP) using a Smith machine. At a later date, subjects performed bench throws using the Smith machine with several different loads ranging from 30.0 kg to 90% of 1RMBP. Barbell positions were measured by a linear position transducer, and bench throw power was calculated using a dynamic equation. Three trials were performed for each load. In all the trials, the maximal peak power was adopted as bench throw peak power (PPBT). The 1RMBP was significantly correlated with MCSAMAx. Similarly, the correlation coefficient between MV and PPBT was significant. In contrast to the y-intercept of the MV-PPBT regression line, that of the MCSAMAx-1RMBP regression line was not significantly different from 0. These results suggested that, although the dependence on pectoralis major muscle size is slightly different between bench press strength and bench throw power, the pectoralis major muscle size has a significant impact on bench press and throw performances. Greater muscle size leads to heavier body weight, which can be a negative factor in some sports. We therefore recommend that athletes and their coaches develop training programs for improving sports performance by balancing the advantage of increased muscle size and the potential disadvantage of increased body weight.
Bench scale demonstration and conceptual engineering for DETOX{sup SM} catalyzed wet oxidation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moslander, J.; Bell, R.; Robertson, D.
1994-06-01
Laboratory and bench scale studies of the DETOX{sup SM} catalyzed wet oxidation process have been performed with the object of developing the process for treatment of hazardous and mixed wastes. Reaction orders, apparent rates, and activation energies have been determined for a range of organic waste surrogates. Reaction intermediates and products have been analyzed. Metals` fates have been determined. Bench scale units have been designed, fabricated, and tested with solid and liquid organic waste surrogates. Results from the laboratory and bench scale studies have been used to develop conceptual designs for application of the process to hazardous and mixed wastes.
Digital Modeling and Testing Research on Digging Mechanism of Deep Rootstalk Crops
NASA Astrophysics Data System (ADS)
Yang, Chuanhua; Xu, Ma; Wang, Zhoufei; Yang, Wenwu; Liao, Xinglong
The digital model of the laboratory bench parts of digging deep rootstalk crops were established through adopting the parametric model technology based on feature. The virtual assembly of the laboratory bench of digging deep rootstalk crops was done and the digital model of the laboratory bench parts of digging deep rootstalk crops was gained. The vibrospade, which is the key part of the laboratory bench of digging deep rootstalk crops was simulated and the movement parametric curves of spear on the vibrospade were obtained. The results show that the spear was accorded with design requirements. It is propitious to the deep rootstalk.
Validating induced seismicity forecast models—Induced Seismicity Test Bench
NASA Astrophysics Data System (ADS)
Király-Proag, Eszter; Zechar, J. Douglas; Gischig, Valentin; Wiemer, Stefan; Karvounis, Dimitrios; Doetsch, Joseph
2016-08-01
Induced earthquakes often accompany fluid injection, and the seismic hazard they pose threatens various underground engineering projects. Models to monitor and control induced seismic hazard with traffic light systems should be probabilistic, forward-looking, and updated as new data arrive. In this study, we propose an Induced Seismicity Test Bench to test and rank such models; this test bench can be used for model development, model selection, and ensemble model building. We apply the test bench to data from the Basel 2006 and Soultz-sous-Forêts 2004 geothermal stimulation projects, and we assess forecasts from two models: Shapiro and Smoothed Seismicity (SaSS) and Hydraulics and Seismics (HySei). These models incorporate a different mix of physics-based elements and stochastic representation of the induced sequences. Our results show that neither model is fully superior to the other. Generally, HySei forecasts the seismicity rate better after shut-in but is only mediocre at forecasting the spatial distribution. On the other hand, SaSS forecasts the spatial distribution better and gives better seismicity rate estimates before shut-in. The shut-in phase is a difficult moment for both models in both reservoirs: the models tend to underpredict the seismicity rate around, and shortly after, shut-in.
NASA Astrophysics Data System (ADS)
Gunes-Lasnet, Sev; Dufour, Jean-Francois
2012-08-01
The potential uses and benefits of wireless technologies in space are very broad. Since many years the CCSDS SOIS wireless working group has worked at the identification of key applications for which wireless would bring benefits, and at supporting the deployment of wireless in space thanks to documents, in particular a Green informative book and magenta books presenting recommended practices.The Smart Sensor Inter-Agency Research Test bench (SSIART) is being designed to provide the space Agencies and the Industry with a reference smart sensor platform to test wireless sensor technologies in reference representative applications and RF propagation environments, while promoting these technologies at the same time.
2007-06-28
femtosecond laser radiation Makin V.S.1, Vorobyev A.Y.2 1 Reseach Inst. for Complex Testing of Opto-Electronic Devices, Sosnovy Bor City, Leningrad...fuel in symmetrical conditions is designed to study DT-mixture compression and heating. To enhance the investigation abilities on this direction the...experimental test bench of average power ∼50 kW with supersonic flow of working medium in the resonator has been developed on its basis. FLAMN-07 3
CPSGrader: Auto-Grading and Feedback Generation for Cyber-Physical Systems Education
2014-12-21
to refer to ⋃ C∈C+ Ω(C,Γ(p)) (and⋃ C∈C− Ω(C,Γ(p))). The rationale behind this choice of ρ is two-fold: 1. To increase coverage of fault detection ... fault mentioned in Section 2.3. The purpose of the test is to detect that at some time instant t0, the robot bumps into the obstacle, then turns about...sampling. 5.6 Investigating Unknown Faults Using Clustering CPSGrader works with a fixed pre-defined library of faults and associated test benches
Using Maximal Isometric Force to Determine the Optimal Load for Measuring Dynamic Muscle Power
NASA Technical Reports Server (NTRS)
Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason R.; Nash, Roxanne E.; Sinka, Joseph; Bloomberg, Jacob J.
2009-01-01
Maximal power output occurs when subjects perform ballistic exercises using loads of 30-50% of one-repetition maximum (1-RM). However, performing 1-RM testing prior to power measurement requires considerable time, especially when testing involves multiple exercises. Maximal isometric force (MIF), which requires substantially less time to measure than 1-RM, might be an acceptable alternative for determining the optimal load for power testing. PURPOSE: To determine the optimal load based on MIF for maximizing dynamic power output during leg press and bench press exercises. METHODS: Twenty healthy volunteers (12 men and 8 women; mean +/- SD age: 31+/-6 y; body mass: 72 +/- 15 kg) performed isometric leg press and bench press movements, during which MIF was measured using force plates. Subsequently, subjects performed ballistic leg press and bench press exercises using loads corresponding to 20%, 30%, 40%, 50%, and 60% of MIF presented in randomized order. Maximal instantaneous power was calculated during the ballistic exercise tests using force plates and position transducers. Repeated-measures ANOVA and Fisher LSD post hoc tests were used to determine the load(s) that elicited maximal power output. RESULTS: For the leg press power test, six subjects were unable to be tested at 20% and 30% MIF because these loads were less than the lightest possible load (i.e., the weight of the unloaded leg press sled assembly [31.4 kg]). For the bench press power test, five subjects were unable to be tested at 20% MIF because these loads were less than the weight of the unloaded aluminum bar (i.e., 11.4 kg). Therefore, these loads were excluded from analysis. A trend (p = 0.07) for a main effect of load existed for the leg press exercise, indicating that the 40% MIF load tended to elicit greater power output than the 60% MIF load (effect size = 0.38). A significant (p . 0.05) main effect of load existed for the bench press exercise; post hoc analysis indicated that the effect of load on power output was: 30% > 40% > 50% = 60%. CONCLUSION: Loads of 40% and 30% of MIF elicit maximal power output during dynamic leg presses and bench presses, respectively. These findings are similar to those obtained when loading is based on 1-RM.
Bassinello, Diogo; de Salles Painelli, Vitor; Dolan, Eimear; Lixandrão, Manoel; Cajueiro, Monique; de Capitani, Mariana; Saunders, Bryan; Sale, Craig; Artioli, Guilherme G; Gualano, Bruno; Roschel, Hamilton
2018-06-15
β-Alanine (BA) supplementation may be ergogenic during high-intensity exercise, primarily due to the buffering of hydrogen cations, although the effects of beta-alanine supplementation on strength endurance are equivocal. The aim of the study was to determine the effects of 4 weeks of beta-alanine supplementation on skeletal muscle endurance using a battery of performance tests. This study employed a parallel group, repeated measures, randomised, double-blinded and placebo-controlled design. Twenty recreationally strength-trained healthy males completed tests of isotonic strength endurance (repeated bench and leg press), along with tests of isometric and isokinetic endurance conducted using an isokinetic dynamometer. Tests were performed before and after a 4 week intervention, comprising an intake of 6.4 g day -1 of BA (n = 9) or placebo (maltodextrin, n = 11). Time-to-exhaustion during the isometric endurance test improved by ~ 17% in the BA group (p < 0.01), while PL remained unchanged. No significant within-group differences (p > 0.1) were shown for any of the performance variables in the isokinetic test (peak torque, fatigue index, total work) nor for the total number of repetitions performed in the isotonic endurance tests (leg or bench press). Four weeks of BA supplementation (6.4 g day -1 ) improved isometric, but not isokinetic or isotonic endurance performance.
The effect of active recovery on power performance during the bench press exercise.
Lopes, Felipe A S; Panissa, Valéria L G; Julio, Ursula F; Menegon, Elton M; Franchini, Emerson
2014-03-27
The objective of this study was to verify the effect of active and passive recovery on blood lactate concentration and power performance. Twelve male subjects were submitted to a maximal strength test in the the bench press, a maximal aerobic test in the bench step, and to four sets of bench press exercise performed as fast and as long as possible, using 80% of maximal strength when active or passive recovery was performed. The maximum number of repetitions, mean and peak power in eccentric and concentric phases were computed and blood lactate concentration was measured. Comparisons for the variables were made using a two-way variance analysis (recovery type and set numer) with repeated measures in the second factor. When significant differences were detected (p < 0.05), a Tukey post-hoc test was used. There was a main effect of set number on maximum number of repetitions (p < 0.05) (1 > 2, 3, and 4; 2 > 3 and 4; 3 > 4). Mean and peak power in both eccentric and concentric phases also differed across sets (1 > 2, 3, and 4; 2 > 4). There was also a main effect for the recovery type, with lower values (p < 0.05) observed for the active recovery compared to the passive one. It can be concluded that active recovery resulted in lower lactate concentration, but did not improve power performance in the bench press exercise.
The Effect of Active Recovery on Power Performance During the Bench Press Exercise
Lopes, Felipe A. S.; Panissa, Valéria L. G.; Julio, Ursula F.; Menegon, Elton M.; Franchini, Emerson
2014-01-01
The objective of this study was to verify the effect of active and passive recovery on blood lactate concentration and power performance. Twelve male subjects were submitted to a maximal strength test in the the bench press, a maximal aerobic test in the bench step, and to four sets of bench press exercise performed as fast and as long as possible, using 80% of maximal strength when active or passive recovery was performed. The maximum number of repetitions, mean and peak power in eccentric and concentric phases were computed and blood lactate concentration was measured. Comparisons for the variables were made using a two-way variance analysis (recovery type and set numer) with repeated measures in the second factor. When significant differences were detected (p < 0.05), a Tukey post-hoc test was used. There was a main effect of set number on maximum number of repetitions (p < 0.05) (1 > 2, 3, and 4; 2 > 3 and 4; 3 > 4). Mean and peak power in both eccentric and concentric phases also differed across sets (1 > 2, 3, and 4; 2 > 4). There was also a main effect for the recovery type, with lower values (p < 0.05) observed for the active recovery compared to the passive one. It can be concluded that active recovery resulted in lower lactate concentration, but did not improve power performance in the bench press exercise. PMID:25031684
Mika, K.B.; Imamura, G.; Chang, C.; Conway, V.; Fernandez, G.; Griffith, J.F.; Kampalath, R.A.; Lee, C.M.; Lin, C.-C.; Moreno, R.; Thompson, S.; Whitman, R.L.; Jay, J.A.
2009-01-01
Aim: Factors affecting faecal indicator bacteria (FIB) and pathogen survival/persistence in sand remain largely unstudied. This work elucidates how biological and physical factors affect die-off in beach sand following sewage spills. Methods and Results: Solar disinfection with mechanical mixing was pilot-tested as a disinfection procedure after a large sewage spill in Los Angeles. Effects of solar exposure, mechanical mixing, predation and/or competition, season, and moisture were tested at bench scale. First-order decay constants for Escherichia coli ranged between -0??23 and -1??02 per day, and for enterococci between -0??5 and -1??0 per day. Desiccation was a dominant factor for E. coli but not enterococci inactivation. Effects of season were investigated through a comparison of experimental results from winter, spring, and fall. Conclusions: Moisture was the dominant factor controlling E. coli inactivation kinetics. Initial microbial community and sand temperature were also important factors. Mechanical mixing, common in beach grooming, did not consistently reduce bacterial levels. Significance and Impact of the Study: Inactivation rates are mainly dependent on moisture and high sand temperature. Chlorination was an effective disinfection treatment in sand microcosms inoculated with raw influent. ?? 2009 The Society for Applied Microbiology.
Beam profile measurements for target designators
NASA Astrophysics Data System (ADS)
Frank, J. D.
1985-02-01
An American aerospace company has conducted a number of investigations with the aim to improve on the tedious slow manual methods of measuring pulsed lasers for rangefinders, giving particular attention to beam divergence which is studied by varying aperture sizes and positions in the laser beam path. Three instruments have been developed to make the involved work easier to perform. One of these, the Automatic Laser Instrumentation and Measurement System (ALIMS), consists of an optical bench, a digital computer, and three bays of associated electronic instruments. ALIMS uses the aperture method to measure laser beam alignment and divergence. The Laser Intensity Profile System (LIPS) consists of a covered optical bench and a two bay electronic equipment and control console. The Automatic Laser Test Set (ALTS) utilizes a 50 x 50 silicon photodiode array to characterize military laser systems automatically. Details regarding the conducted determinations are discussed.
Grahn, Dennis A; Cao, Vinh H; Nguyen, Christopher M; Liu, Mengyuan T; Heller, H Craig
2012-09-01
Body core cooling via the palm of a hand increases work volume during resistive exercise. We asked: (a) "Is there a correlation between elevated core temperatures and fatigue onset during resistive exercise?" and (b) "Does palm cooling between sets of resistive exercise affect strength and work volume training responses?" Core temperature was manipulated by 30-45 minutes of fixed load and duration treadmill exercise in the heat with or without palm cooling. Work volume was then assessed by 4 sets of fixed load bench press exercises. Core temperatures were reduced and work volumes increased after palm cooling (Control: Tes = 39.0 ± 0.1° C, 36 ± 7 reps vs. Cooling: Tes = 38.4 ± 0.2° C, 42 ± 7 reps, mean ± SD, n = 8, p < 0.001). In separate experiments, the impact of palm cooling on work volume and strength training responses were assessed. The participants completed biweekly bench press or pull-up exercises for multiple successive weeks. Palm cooling was applied for 3 minutes between sets of exercise. Over 3 weeks of bench press training, palm cooling increased work volume by 40% (vs. 13% with no treatment; n = 8, p < 0.05). Over 6 weeks of pull-up training, palm cooling increased work volume by 144% in pull-up experienced subjects (vs. 5% over 2 weeks with no treatment; n = 7, p < 0.001) and by 80% in pull-up naïve subjects (vs. 20% with no treatment; n = 11, p < 0.01). Strength (1 repetition maximum) increased 22% over 10 weeks of pyramid bench press training (4 weeks with no treatment followed by 6 weeks with palm cooling; n = 10, p < 0.001). These results verify previous observations about the effects of palm cooling on work volume, demonstrate a link between core temperature and fatigue onset during resistive exercise, and suggest a novel means for improving strength and work volume training responses.
Test-retest reliability of barbell velocity during the free-weight bench-press exercise.
Stock, Matt S; Beck, Travis W; DeFreitas, Jason M; Dillon, Michael A
2011-01-01
The purpose of this study was to calculate test-retest reliability statistics for peak barbell velocity during the free-weight bench-press exercise for loads corresponding to 10-90% of the 1-repetition maximum (1RM). Twenty-one healthy, resistance-trained men (mean ± SD age = 23.5 ± 2.7 years; body mass = 90.5 ± 14.6 kg; 1RM bench press = 125.4 ± 18.4 kg) volunteered for this study. A minimum of 48 hours after a maximal strength testing and familiarization session, the subjects performed single repetitions of the free-weight bench-press exercise at each tenth percentile (10-90%) of the 1RM on 2 separate occasions. For each repetition, the subjects were instructed to press the barbell as rapidly as possible, and peak barbell velocity was measured with a Tendo Weightlifting Analyzer. The test-retest intraclass correlation coefficients (model 2,1) and corresponding standard errors of measurement (expressed as percentages of the mean barbell velocity values) were 0.717 (4.2%), 0.572 (5.0%), 0.805 (3.1%), 0.669 (4.7%), 0.790 (4.6%), 0.785 (4.8%), 0.811 (5.8%), 0.714 (10.3%), and 0.594 (12.6%) for the weights corresponding to 10-90% 1RM. There were no mean differences between the barbell velocity values from trials 1 and 2. These results indicated moderate to high test-retest reliability for barbell velocity from 10 to 70% 1RM but decreased consistency at 80 and 90% 1RM. When examining barbell velocity during the free-weight bench-press exercise, greater measurement error must be overcome at 80 and 90% 1RM to be confident that an observed change is meaningful.
NASA Astrophysics Data System (ADS)
Burdukov, A. P.; Chernetskiy, M. Yu.; Dekterev, A. A.; Anufriev, I. S.; Strizhak, P. A.; Greben'kov, P. Yu.
2016-01-01
Results of investigation of furnace processes upon burning of pulverized fuel at a test bench with a power of 5 MW are presented. The test bench consists of two stages with tangential air and pulverized coal feed, and it is equipped by a vibrocentrifugal mill and a disintegrator. Such milling devices have an intensive mechanical impact on solid organic fuel, which, in a number of cases, increases the reactivity of ground material. The processes of ignition and stable combustion of a mixture of gas coal and sludge (wastes of concentration plant), as well as Ekibastus coal, ground in the disintegrator, were studied at the test bench. The results of experimental burning demonstrated that preliminary fuel grinding in the disintegrator provides autothermal combustion mode even for hardly inflammable organic fuels. Experimental combustion of biomass, wheat straw with different lignin content (18, 30, 60%) after grinding in the disintegrator, was performed at the test bench in order to determine the possibility of supporting stable autothermal burning. Stable biofuel combustion mode without lighting by highly reactive fuel was achieved in the experiments. The influence of the additive GTS-Powder (L.O.M. Leaders Co., Ltd., Republic of Korea) in the solid and liquid state on reducing sulfur oxide production upon burning Mugun coal was studied. The results of experimental combustion testify that, for an additive concentration from 1 to 15% of the total mass of the burned mixture, the maximum SO2 concentration reduction in ejected gases was not more than 18% with respect to the amount for the case of burning pure coal.
Segment phasing experiments on the High Order Test bench
NASA Astrophysics Data System (ADS)
Aller-Carpentier, E.; Kasper, M.; Martinez, P.
The segmented primary mirror of the E-ELT imposes particular requirements on an Extreme Adaptive Optics (XAO) system. At present, there are already several AO systems working on segmented telescopes but the achieved performances are too low to draw conclusions for XAO systems aiming at some 90% Strehl ratio in the NIR. On other hand, several analytical studies and simulations were done, but laboratory studies are required to confirm the corrections expected. The goal of the present study is to determina the capability of XAO systems to deal with segmentation piston errors. In particular, the effects on the AO performance and the ability of the AO system to correct the segmentation piston errors were studied. The experiments were carried out on the High Order Test Bench at ESO (Munich) using a Shack-Hartmann wave front sensor and under most realistic conditions with phase screens simulating atmospheric turbulence and segmentation piston errors. Segment geometry was chosen such that about 6 actuators of the XAO DM cover one segment representing the design of EPICS at the EELT.
Rogers, Benjamin H; Brown, Justin C; Gater, David R; Schmitz, Kathryn H
2017-02-01
To characterize the relationship between 1-repetition maximum (1-RM) bench press strength and isometric handgrip strength among breast cancer survivors. Cross-sectional study. Laboratory. Community-dwelling breast cancer survivors (N=295). Not applicable. 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer, with 3 maximal contractions of the left and right hands. All measures were conducted by staff with training in clinical exercise testing. Among 295 breast cancer survivors, 1-RM bench press strength was 18.2±6.1kg (range, 2.2-43.0kg), and isometric handgrip strength was 23.5±5.8kg (range, 9.0-43.0kg). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=.399; P<.0001). Mean difference analysis suggested that the average isometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7kg (95% limits of agreement, -8.2 to 17.6kg). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=.31; P<.0001) and age (β=-.20; P<.0001) were positively correlated with 1-RM bench press strength (R 2 =.23). Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among breast cancer survivors. 1-RM bench press strength and isometric handgrip strength quantify distinct components of muscular strength. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Denadai, Rafael; Oshiiwa, Marie; Saad-Hossne, Rogério
2014-03-01
The search for alternative and effective forms of training simulation is needed due to ethical and medico-legal aspects involved in training surgical skills on living patients, human cadavers and living animals. To evaluate if the bench model fidelity interferes in the acquisition of elliptical excision skills by novice medical students. Forty novice medical students were randomly assigned to 5 practice conditions with instructor-directed elliptical excision skills' training (n = 8): didactic materials (control); organic bench model (low-fidelity); ethylene-vinyl acetate bench model (low-fidelity); chicken legs' skin bench model (high-fidelity); or pig foot skin bench model (high-fidelity). Pre- and post-tests were applied. Global rating scale, effect size, and self-perceived confidence based on Likert scale were used to evaluate all elliptical excision performances. The analysis showed that after training, the students practicing on bench models had better performance based on Global rating scale (all P < 0.0000) and felt more confident to perform elliptical excision skills (all P < 0.0000) when compared to the control. There was no significant difference (all P > 0.05) between the groups that trained on bench models. The magnitude of the effect (basic cutaneous surgery skills' training) was considered large (>0.80) in all measurements. The acquisition of elliptical excision skills after instructor-directed training on low-fidelity bench models was similar to the training on high-fidelity bench models; and there was a more substantial increase in elliptical excision performances of students that trained on all simulators compared to the learning on didactic materials.
Machine Shop. Module 3: Bench Work and Material Science. Instructor's Guide.
ERIC Educational Resources Information Center
Walden, Charles H.; Nobles, Jack
This document consists of materials for an 11-unit course on the following topics: (1) hacksawing; (2) filing and deburring; (3) locating centers for drilling; (4) cutting threads with tap and die; (5) using a hand reamer; (6) pedestal/bench grinder operation; (7) whetting, polishing, and lapping; (8) screw, drill, and tap extraction; (9) arbor…
Estimation of light commercial vehicles dynamics by means of HIL-testbench simulation
NASA Astrophysics Data System (ADS)
Groshev, A.; Tumasov, A.; Toropov, E.; Sereda, P.
2018-02-01
The high level of active safety of vehicles is impossible without driver assistance electronic systems. Electronic stability control (ESC) system is one of them. Nowadays such systems are obligatory for installation on vehicles of different categories. The approval of active safety level of vehicles with ESC is possible by means of high speed road tests. The most frequently implemented tests are “fish hook” and “sine with dwell” tests. Such kind of tests provided by The Global technical regulation No. 8 are published by the United Nations Economic Commission for Europe as well as by ECE 13-11. At the same time, not only road tests could be used for estimation of vehicles dynamics. Modern software and hardware technologies allow imitating real tests with acceptable reliability and good convergence between real test data and simulation results. ECE 13-11 Annex 21 - Appendix 1 “Use Of The Dynamic Stability Simulation” regulates demands for special Simulation Test bench that could be used not only for preliminary estimation of vehicles dynamics, but also for official vehicles homologation. This paper describes the approach, proposed by the researchers from Nizhny Novgorod State Technical University n.a. R.E. Alekseev (NNSTU, Russia) with support of engineers of United Engineering Center GAZ Group, as well as specialists of Gorky Automobile Plant. The idea of approach is to use the special HIL (hardware in the loop) -test bench, that consists of Real Time PC with Real Time Software and braking system components including electronic control unit (ECU) of ESC system. The HIL-test bench allows imitating vehicle dynamics in condition of “fish hook” and “sine with dwell” tests. The paper describes the scheme and structure of HIL-test bench and some peculiarities that should be taken into account during HIL-simulation.
Tylko, Suzanne; Locey, Caitlin M.; Garcia-Espana, J. Felipe; Arbogast, Kristy B.; Maltese, Matthew R.
2013-01-01
The purpose of this study was to compare the dynamic response of rear-facing child restraint systems (RFCRS) installed on the CMVSS 213 sled bench and a selection of vehicle seats. Thirty-six sled tests were conducted: three models of rear facing CRS with an anthropomorphic test device (ATD) representing a 12 month old child (CRABI) were affixed via lower anchors (LATCH), 3 point belt without CRS base, and 3 point belt with CRS base to one of three vehicle seats or the CMVSS 213 bench seat. All CRS were subjected to an identical sled acceleration pulse. Two types of matched pair analysis: “bench-to-vehicle” and “method of attachment” were conducted. Statistically significant differences were observed in the kinematic responses of the ATD and the CRS. This is the first study to quantify differences between the regulatory bench and vehicle seats on a system level and evaluate the influence of attachment method. Our results show that the difference in RFCRS forward excursion between 3-point belt with base and LATCH installations was between 1 and 7 percent on the bench and 22 to 76 percent on the vehicle seats. When evaluating the dynamic performance of RFCRS, the use of real vehicle seats from vehicles that commonly carry children may provide valuable insight. The findings would require further confirmation using a broader selection of RFCRS and vehicle seats, before generalizable conclusions can be drawn. PMID:24406967
Foaming phenomenon in bench-scale anaerobic digesters.
Siebels, Amanda M; Long, Sharon C
2013-04-01
The Madison Metropolitan Sewerage District (The District) in Madison, Wisconsin has been experiencing seasonal foaming in their anaerobic biosolids digesters, which has occurred from mid-November to late June for the past few years. The exact cause(s) of foaming is unknown. Previous research findings are unclear as to whether applications of advanced anaerobic digestion processes reduce the foaming potential of digesters. The object of this study was to investigate how configurations of thermophilic and acid phase-thermophilic anaerobic digestion would affect foaming at the bench-scale level compared to single stage mesophilic digestion for The District. Bench-scale anaerobic digesters were fed with a 4 to 4.5% by dry weight of solids content blend of waste activated sludge (WAS) and primary sludge from The District. Foaming potential was monitored using Alka-Seltzer and aeration foaming tests. The bench-scale acid phase-thermophilic digester had a higher foaming potential than the bench-scale mesophilic digester. These results indicate that higher temperatures increase the foaming potential of the bench-scale anaerobic digesters. The bench-scale acid phase-thermophilic digesters had a greater percent (approximately 5 to 10%) volatile solids destruction and a greater percent (approximately 5 to 10%) total solids destruction when compared to the bench-scale mesophilic digester. Overall, for the full-scale foaming experienced by The District, it appears that adding an acid phase or switching to thermophilic digestion would not alleviate The District's foaming issues.
New Improvements in Magnetic Measurements Laboratory of the ALBA Synchrotron Facility
NASA Astrophysics Data System (ADS)
Campmany, Josep; Marcos, Jordi; Massana, Valentí
ALBA synchrotron facility has a complete insertion devices (ID) laboratory to characterize and produce magnetic devices needed to satisfy the requirements of ALBA's user community. The laboratory is equipped with a Hall-probe bench working in on-the-fly measurement mode allowing the measurement of field maps of big magnetic structures with high accuracy, both in magnetic field magnitude and position. The whole control system of this bench is based on TANGO. The Hall probe calibration range extends between sub-Gauss to 2 Tesla with an accuracy of 100 ppm. Apart from the Hall probe bench, the ID laboratory has a flipping coil bench dedicated to measuring field integrals and a Helmholtz coil bench specially designed to characterize permanent magnet blocks. Also, a fixed stretched wire bench is used to measure field integrals of magnet sets. This device is specifically dedicated to ID construction. Finally, the laboratory is equipped with a rotating coil bench, specially designed for measuring multipolar devices used in accelerators, such as quadrupoles, sextupoles, etc. Recent improvements of the magnetic measurements laboratory of ALBA synchrotron include the design and manufacturing of very thin 3D Hall probe heads, the design and manufacturing of coil sensors for the Rotating coil bench based on multilayered PCB, and the improvement of calibration methodology in order to improve the accuracy of the measurements. ALBA magnetic measurements laboratory is open for external contracts, and has been widely used by national and international institutes such as CERN, ESRF or CIEMAT, as well as magnet manufacturing companies, such as ANTEC, TESLA and I3 M. In this paper, we will present the main features of the measurement benches as well as improvements made so far.
Burbank works on the CIR in the U.S. Laboratory
2012-04-10
ISS030-E-234735 (10 April 2012) --- NASA astronaut Dan Burbank, Expedition 30 commander, works on the Combustion Integrated Rack (CIR) in the Destiny laboratory of the International Space Station. Burbank disconnected the Moderate Temperature Loop (MTL), Vacuum Exhaust System (VES) and station nitrogen lines of the Optics Bench, translated and rotated it out of the way and replaced a Fluids and Combustion Facility / Diagnostic Control Module (FCF DCM) on its back. Afterwards, Burbank returned the Optics Bench to its nominal position and reconnected the MTL, VES and station nitrogen lines.
Flight test of a full authority Digital Electronic Engine Control system in an F-15 aircraft
NASA Technical Reports Server (NTRS)
Barrett, W. J.; Rembold, J. P.; Burcham, F. W.; Myers, L.
1981-01-01
The Digital Electronic Engine Control (DEEC) system considered is a relatively low cost digital full authority control system containing selectively redundant components and fault detection logic with capability for accommodating faults to various levels of operational capability. The DEEC digital control system is built around a 16-bit, 1.2 microsecond cycle time, CMOS microprocessor, microcomputer system with approximately 14 K of available memory. Attention is given to the control mode, component bench testing, closed loop bench testing, a failure mode and effects analysis, sea-level engine testing, simulated altitude engine testing, flight testing, the data system, cockpit, and real time display.
Fabrication, test and demonstration of critical environment monitoring system
NASA Technical Reports Server (NTRS)
Heimendinger, K. W.
1972-01-01
Design and performance of an analytical system for the evaluation of certain environmental constituents in critical environmental areas of the Quality Reliability and Assurance Laboratory are reported. Developed was a self-contained, integrated, minimum sized unit that detects, interrogates, and records those parameters of the environment dictated for control in large storage facilities, clean rooms, temporarily curtained enclosures, and special working benches. The system analyzes humidity, temperature, hydrocarbons particle size, and particle count within prescribed clean areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-12-31
The US Department of Energy (DOE) Morgantown Energy Technology Center (METC) is sponsoring research in advanced methods for controlling contaminants in hot coal gasifier gas (coal gas) streams of integrated gasification combined-cycle (IGCC) power systems. The programs focus on hot-gas particulate removal and desulfurization technologies that match or nearly match the temperatures and pressures of the gasifier, cleanup system, and power generator. The work seeks to eliminate the need for expensive heat recovery equipment, reduce efficiency losses due to quenching, and minimize wastewater treatment costs. The goal of this project is to continue further development of the zinc titanate desulfurizationmore » and direct sulfur recovery process (DSRP) technologies by (1) scaling up the zinc titanate reactor system; (2) developing an integrated skid-mounted zinc titanate desulfurization-DSRP reactor system; (3) testing the integrated system over an extended period with real coal-as from an operating gasifier to quantify the degradative effect, if any, of the trace contaminants present in cola gas; (4) developing an engineering database suitable for system scaleup; and (5) designing, fabricating and commissioning a larger DSRP reactor system capable of operating on a six-fold greater volume of gas than the DSRP reactor used in the bench-scale field test. The work performed during the April 1 through June 30, 1996 period is described.« less
Ultraviolet Communication for Medical Applications
2013-06-01
sky was clear and no moonlight was visible during testing. There was light fog and high pollen count (9 grains per m3), and relative humidity was...improved LED light source was evaluated outdoors using the test bench system at a range of 50 m, and received photon counts were consistent with...bench system at a range of 50 m, and received photon counts were consistent with medium data rate communication. Future Phase II efforts will develop
Denadai, Rafael; Oshiiwa, Marie; Saad-Hossne, Rogério
2014-01-01
Background: The search for alternative and effective forms of training simulation is needed due to ethical and medico-legal aspects involved in training surgical skills on living patients, human cadavers and living animals. Aims: To evaluate if the bench model fidelity interferes in the acquisition of elliptical excision skills by novice medical students. Materials and Methods: Forty novice medical students were randomly assigned to 5 practice conditions with instructor-directed elliptical excision skills’ training (n = 8): didactic materials (control); organic bench model (low-fidelity); ethylene-vinyl acetate bench model (low-fidelity); chicken legs’ skin bench model (high-fidelity); or pig foot skin bench model (high-fidelity). Pre- and post-tests were applied. Global rating scale, effect size, and self-perceived confidence based on Likert scale were used to evaluate all elliptical excision performances. Results: The analysis showed that after training, the students practicing on bench models had better performance based on Global rating scale (all P < 0.0000) and felt more confident to perform elliptical excision skills (all P < 0.0000) when compared to the control. There was no significant difference (all P > 0.05) between the groups that trained on bench models. The magnitude of the effect (basic cutaneous surgery skills’ training) was considered large (>0.80) in all measurements. Conclusion: The acquisition of elliptical excision skills after instructor-directed training on low-fidelity bench models was similar to the training on high-fidelity bench models; and there was a more substantial increase in elliptical excision performances of students that trained on all simulators compared to the learning on didactic materials. PMID:24700937
Nelson, Kären C.; Marbach-Ad, Gili; Keller, Michael; Fagan, William F.
2010-01-01
There is widespread agreement within the scientific and education communities that undergraduate biology curricula fall short in providing students with the quantitative and interdisciplinary problem-solving skills they need to obtain a deep understanding of biological phenomena and be prepared fully to contribute to future scientific inquiry. MathBench Biology Modules were designed to address these needs through a series of interactive, Web-based modules that can be used to supplement existing course content across the biological sciences curriculum. The effect of the modules was assessed in an introductory biology course at the University of Maryland. Over the course of the semester, students showed significant increases in quantitative skills that were independent of previous math course work. Students also showed increased comfort with solving quantitative problems, whether or not they ultimately arrived at the correct answer. A survey of spring 2009 graduates indicated that those who had experienced MathBench in their course work had a greater appreciation for the role of mathematics in modern biology than those who had not used MathBench. MathBench modules allow students from diverse educational backgrounds to hone their quantitative skills, preparing them for more complex mathematical approaches in upper-division courses. PMID:20810959
Thompson, Katerina V; Nelson, Kären C; Marbach-Ad, Gili; Keller, Michael; Fagan, William F
2010-01-01
There is widespread agreement within the scientific and education communities that undergraduate biology curricula fall short in providing students with the quantitative and interdisciplinary problem-solving skills they need to obtain a deep understanding of biological phenomena and be prepared fully to contribute to future scientific inquiry. MathBench Biology Modules were designed to address these needs through a series of interactive, Web-based modules that can be used to supplement existing course content across the biological sciences curriculum. The effect of the modules was assessed in an introductory biology course at the University of Maryland. Over the course of the semester, students showed significant increases in quantitative skills that were independent of previous math course work. Students also showed increased comfort with solving quantitative problems, whether or not they ultimately arrived at the correct answer. A survey of spring 2009 graduates indicated that those who had experienced MathBench in their course work had a greater appreciation for the role of mathematics in modern biology than those who had not used MathBench. MathBench modules allow students from diverse educational backgrounds to hone their quantitative skills, preparing them for more complex mathematical approaches in upper-division courses.
This bench-scale study was conducted to evaluate the stabilization of mercury (Hg) and mercuric chloride-containing surrogate test materials by the chemically bonded phosphate ceramics technology. This study was performed as part of a U.S. EPA program to evaluate treatment and d...
BENCH-SCALE EVALUATION OF CALCIUM SORBENTS FOR ACID GAS EMISSION CONTROL
Calcium sorbents for acid gas emission control were evaluated for effectiveness in removing SO2/HCl and SO2/NO from simulated incinerator and boiler flue gases. All tests were conducted in a bench-scale reactor (fixed-bed) simulating fabric filter conditions in an acid gas remova...
Using bench press load to predict upper body exercise loads in physically active individuals.
Wong, Del P; Ngo, Kwan-Lung; Tse, Michael A; Smith, Andrew W
2013-01-01
This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m(-2)) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p < 0.01). The bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p < 0.01). Linear regression revealed that the bench press load was a significant (R(2) range from 0.64 to 0.86, p < 0.01) predictor for the loads of the 4 assistance exercises. The following 6RM prediction equations were determined: (a) Hammer curl = Bench press load (0.28) + 6.30 kg, (b) Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key pointsThe bench press load was significantly correlated with the loads of the 4 assistance exercises.No significant differences were found between the actual load and the predicted load in the four equations.6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises.
Using Bench Press Load to Predict Upper Body Exercise Loads in Physically Active Individuals
Wong, Del P.; Ngo, Kwan-Lung; Tse, Michael A.; Smith, Andrew W.
2013-01-01
This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m-2) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p < 0.01). The bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p < 0.01). Linear regression revealed that the bench press load was a significant (R2 range from 0.64 to 0.86, p < 0.01) predictor for the loads of the 4 assistance exercises. The following 6RM prediction equations were determined: (a) Hammer curl = Bench press load (0.28) + 6.30 kg, (b) Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key points The bench press load was significantly correlated with the loads of the 4 assistance exercises. No significant differences were found between the actual load and the predicted load in the four equations. 6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises. PMID:24149723
NASA Astrophysics Data System (ADS)
Ola, Max; Thomas, Christiane; Hesse, Ullrich
2017-08-01
Compressor performance test procedures are defined by the standard DIN EN 13771, wherein a variety of possible calorimeter and flow rate measurement methods are suggested. One option is the selection of two independent measurement methods. The accuracies of both selected measurement methods are essential. The second option requires only one method. However the measurement accuracy of the used device has to be verified and recalibrated on a regular basis. The compressor performance test facility at the Technische Universitaet Dresden uses a calibrated flow measurement sensor, a hot gas bypass and a mixed flow heat exchanger. The test bench can easily be modified for tests of various compressor types at different operating ranges and with various refrigerants. In addition, the modified test setup enables the investigation of long term liquid slug and its effects on the compressor. The modification comprises observational components, adjustments of the control system, safety measures and a customized oil recirculation system for compressors which do not contain an integrated oil sump or oil level regulation system. This paper describes the setup of the test bench, its functional principle, the key modifications, first test results and an evaluation of the energy balance.
Experimental and theoretical study of friction torque from radial ball bearings
NASA Astrophysics Data System (ADS)
Geonea, Ionut; Dumitru, Nicolae; Dumitru, Ilie
2017-10-01
In this paper it is presented a numerical simulation and an experimental study of total friction torque from radial ball bearings. For this purpose it is conceived a virtual CAD model of the experimental test bench for bearing friction torque measurement. The virtual model it is used for numerical simulation in Adams software, that allows dynamic study of multi-body systems and in particularly with facility Adams Machinery of dynamic behavior of machine parts. It is manufactured an experimental prototype of the test bench for radial ball bearings friction torque measurement. In order to measure the friction torque of the tested bearings it is used an equal resistance elastic beam element, with strain gauge transducer to measure bending deformations. The actuation electric motor of the bench has the shaft mounted on two bearings and the motor housing is fixed to the free side of the elastic beam, which is bended by a force proportional with the total friction torque. The beam elastic element with strain gauge transducer is calibrated in order to measure the force occurred. Experimental determination of the friction torque is made for several progressive radial loads. It is established the correlation from the friction torque and bearing radial load. The bench allows testing of several types and dimensions of radial bearings, in order to establish the bearing durability and of total friction torque.
Design, assembly, and metrology of an oil-immersion microscope objective with long working distance
NASA Astrophysics Data System (ADS)
Peng, Wei-Jei; Lin, Wen-Lung; Kuo, Hui-Jean; Ho, Cheng-Fang; Hsu, Wei-Yao
2016-10-01
The design, tolerance sensitivity reduction, assembly, and optical bench test for an oil-immersion microscope objective with long working distance employed in a lattice light-sheet microscope is presented in this paper. In this application, the orthogonal excitation and detection objectives are dipped in an oil medium. The excitation objective focuses the incident laser beam to generate fluorescence on specimen for collecting by detection objective. The excitation objective is custom-designed to meet the requirement specification such as oil-immersion, the long working distance, and numerical aperture (NA) of 0.5, etc. To produce an acceptable point spread function (PSF) for effective excitation, the performance of the objective needs to be close to diffraction limit. Because the tolerance of the modulation transfer function (MTF) is more and more sensitive at higher spatial frequency, it is extremely critical to keep the performance after manufacture. Consequently, an insensitive optical design is very important for relaxing tolerance. We compare the design with and without tolerance sensitivity reduction, and the as-built MTF shows the result. Furthermore, the method for sensitivity reduction is presented. The opto-mechanical design and assembly method are also discussed. Eventually, the objective with five spherical lenses was fabricated. In optical bench test, the depth of the oil is sensitive to MTF, and it leads to the complicated adjustment. For solving this issue, we made an index-matching lens to replace oil for measurement easily. Finally, the measured MTF of the excitation objective can accomplish the requirement specification and successfully employed in a lattice light-sheet microscope.
26. July 1974. BENCH SHOP, VIEW LOOKING SOUTH, SHOWING THE ...
26. July 1974. BENCH SHOP, VIEW LOOKING SOUTH, SHOWING THE BORING MACHINE PURCHASED IN 1885. THE BIT MAY BE LOWERED BY THE HANGING LINKAGE OR THE TABLE RAISED BY THE FOOT PEDAL. NOTICE THE CHASE FOR THE BELTS, BUILT NO LESS CAREFULLY THAN THE MACHINE ITSELF. - Gruber Wagon Works, Pennsylvania Route 183 & State Hill Road at Red Bridge Park, Bernville, Berks County, PA
MULTICOMPONENT AEROSOL DYNAMICS OF THE PB-O2 SYSTEM IN A BENCH SCALE FLAME INCINERATOR
A study was carried out to understand the formation and growth of lead particles in a flame incinerator. A bench scale flame incinerator was used to perform controlled experiments with lead acetate as a test compound. A dilution probe in conjunction with real-time aerosol instrum...
Crash Testing of Helicopter Airframe Fittings
NASA Technical Reports Server (NTRS)
Clarke, Charles W.; Townsend, William; Boitnott, Richard
2004-01-01
As part of the Rotary Wing Structures Technology Demonstration (RWSTD) program, a surrogate RAH-66 seat attachment fitting was dynamically tested to assess its response to transient, crash impact loads. The dynamic response of this composite material fitting was compared to the performance of an identical fitting subjected to quasi-static loads of similar magnitude. Static and dynamic tests were conducted of both smaller bench level and larger full-scale test articles. At the bench level, the seat fitting was supported in a steel fixture, and in the full-scale tests, the fitting was integrated into a surrogate RAH-66 forward fuselage. Based upon the lessons learned, an improved method to design, analyze, and test similar composite material fittings is proposed.
Acute chest pain after bench press exercise in a healthy young adult.
Smereck, Janet A; Papafilippaki, Argyro; Sudarshan, Sawali
2016-01-01
Bench press exercise, which involves repetitive lifting of weights to full arm extension while lying supine on a narrow bench, has been associated with complications ranging in acuity from simple pectoral muscle strain, to aortic and coronary artery dissection. A 39-year-old man, physically fit and previously asymptomatic, presented with acute chest pain following bench press exercise. Diagnostic evaluation led to the discovery of critical multivessel coronary occlusive disease, and subsequently, highly elevated levels of lipoprotein (a). Judicious use of ancillary testing may identify the presence of "high-risk" conditions in a seemingly "low-risk" patient. Emergency department evaluation of the young adult with acute chest pain must take into consideration an extended spectrum of potential etiologies, so as to best guide appropriate management.
A New Optical Bench Concept for Space-Based Laser Interferometric Gravitational Wave Missions
NASA Astrophysics Data System (ADS)
Chilton, Andrew; Apple, Stephen; Ciani, Giacomo; Olatunde, Taiwo; Conklin, John; Mueller, Guido
2015-04-01
Space-based interferometric gravitational wave detectors such as LISA have been proposed to detect low-frequency gravitational wave sources such as the inspirals of compact objects into massive black holes or two massive black holes into each other. The optical components used to perform the high-precision interferometry required to make these measurements have historically been bonded to Zerodur optical benches, which are thermally ultrastable but difficult and time-consuming to manufacture. More modern implementations of LISA-like interferometry have reduced the length stability requirement on these benches from 30fm/√{Hz} to a few pm √{ Hz}. We therefore propose to alter the design of the optical bench in such a way as to no longer require the use of Zerodur; instead, we plan to replace it with more easily-used materials such as titanium or molybdenum. In this presentation, we discuss the current status of and future plans for the construction and testing of such an optical bench.
2013-09-01
followed by an exhaust nozzle . He considered the turbojet as a hybrid of “propeller gas turbine” and “rocket” principles. In 1936, he then conceived...first bench-test of a jet engine using liquid fuel. Simultaneous with Whittle, a German scientist was making great headway into gas turbine engine...deviations, secondary flows, and similar loss producing phenomena. The results are applicable to both military and civil applications of gas turbine
Sensory feedback in prosthetics: a standardized test bench for closed-loop control.
Dosen, Strahinja; Markovic, Marko; Hartmann, Cornelia; Farina, Dario
2015-03-01
Closing the control loop by providing sensory feedback to the user of a prosthesis is an important challenge, with major impact on the future of prosthetics. Developing and comparing closed-loop systems is a difficult task, since there are many different methods and technologies that can be used to implement each component of the system. Here, we present a test bench developed in Matlab Simulink for configuring and testing the closed-loop human control system in standardized settings. The framework comprises a set of connected generic blocks with normalized inputs and outputs, which can be customized by selecting specific implementations from a library of predefined components. The framework is modular and extensible and it can be used to configure, compare and test different closed-loop system prototypes, thereby guiding the development towards an optimal system configuration. The use of the test bench was demonstrated by investigating two important aspects of closed-loop control: performance of different electrotactile feedback interfaces (spatial versus intensity coding) during a pendulum stabilization task and feedforward methods (joystick versus myocontrol) for force control. The first experiment demonstrated that in the case of trained subjects the intensity coding might be superior to spatial coding. In the second experiment, the control of force was rather poor even with a stable and precise control interface (joystick), demonstrating that inherent characteristics of the prosthesis can be an important limiting factor when considering the overall effectiveness of the closed-loop control. The presented test bench is an important instrument for investigating different aspects of human manual control with sensory feedback.
AnaBench: a Web/CORBA-based workbench for biomolecular sequence analysis
Badidi, Elarbi; De Sousa, Cristina; Lang, B Franz; Burger, Gertraud
2003-01-01
Background Sequence data analyses such as gene identification, structure modeling or phylogenetic tree inference involve a variety of bioinformatics software tools. Due to the heterogeneity of bioinformatics tools in usage and data requirements, scientists spend much effort on technical issues including data format, storage and management of input and output, and memorization of numerous parameters and multi-step analysis procedures. Results In this paper, we present the design and implementation of AnaBench, an interactive, Web-based bioinformatics Analysis workBench allowing streamlined data analysis. Our philosophy was to minimize the technical effort not only for the scientist who uses this environment to analyze data, but also for the administrator who manages and maintains the workbench. With new bioinformatics tools published daily, AnaBench permits easy incorporation of additional tools. This flexibility is achieved by employing a three-tier distributed architecture and recent technologies including CORBA middleware, Java, JDBC, and JSP. A CORBA server permits transparent access to a workbench management database, which stores information about the users, their data, as well as the description of all bioinformatics applications that can be launched from the workbench. Conclusion AnaBench is an efficient and intuitive interactive bioinformatics environment, which offers scientists application-driven, data-driven and protocol-driven analysis approaches. The prototype of AnaBench, managed by a team at the Université de Montréal, is accessible on-line at: . Please contact the authors for details about setting up a local-network AnaBench site elsewhere. PMID:14678565
Experimental performance and acoustic investigation of modern, counterrotating blade concepts
NASA Technical Reports Server (NTRS)
Hoff, G. E.
1990-01-01
The aerodynamic, acoustic, and aeromechanical performance of counterrotating blade concepts were evaluated both theoretically and experimentally. Analytical methods development and design are addressed. Utilizing the analytical methods which evolved during the conduct of this work, aerodynamic and aeroacoustic predictions were developed, which were compared to NASA and GE wind tunnel test results. The detailed mechanical design and fabrication of five different composite shell/titanium spar counterrotating blade set configurations are presented. Design philosophy, analyses methods, and material geometry are addressed, as well as the influence of aerodynamics, aeromechanics, and aeroacoustics on the design procedures. Blade fabrication and quality control procedures are detailed; bench testing procedures and results of blade integrity verification are presented; and instrumentation associated with the bench testing also is identified. Additional hardware to support specialized testing is described, as are operating blade instrumentation and the associated stress limits. The five counterrotating blade concepts were scaled to a tip diameter of 2 feet, so they could be incorporated into MPS (model propulsion simulators). Aerodynamic and aeroacoustic performance testing was conducted in the NASA Lewis 8 x 6 supersonic and 9 x 15 V/STOL (vertical or short takeoff and landing) wind tunnels and in the GE freejet anechoic test chamber (Cell 41) to generate an experimental data base for these counterrotating blade designs. Test facility and MPS vehicle matrices are provided, and test procedures are presented. Effects on performance of rotor-to-rotor spacing, angle-of-attack, pylon proximity, blade number, reduced-diameter aft blades, and mismatched rotor speeds are addressed. Counterrotating blade and specialized aeromechanical hub stability test results are also furnished.
Ferreira, Diogo V; Gentil, Paulo; Ferreira-Junior, João B; Soares, Saulo R S; Brown, Lee E; Bottaro, Martim
2017-10-01
To evaluate the time course of peak torque and total work recovery after a resistance training session involving the bench press exercise. Repeated measures with a within subject design. Twenty-six resistance-trained men (age: 23.7±3.7years; height: 176.0±5.7cm; mass: 79.65±7.61kg) performed one session involving eight sets of the bench press exercise performed to momentary muscle failure with 2-min rest between sets. Shoulder horizontal adductors peak torque (PT), total work (TW), delayed onset muscle soreness (DOMS) and subjective physical fitness were measured pre, immediately post, 24, 48, 72 and 96h following exercise. The exercise protocol resulted in significant pectoralis major DOMS that lasted for 72h. Immediately after exercise, the reduction in shoulder horizontal adductors TW (25%) was greater than PT (17%). TW, as a percentage of baseline values, was also less than PT at 24, 48 and 96h after exercise. Additionally, PT returned to baseline at 96h, while TW did not. Resistance trained men presented dissimilar PT and TW recovery following free weight bench press exercise. This indicates that recovery of maximal voluntary contraction does not reflect the capability to perform multiple contractions. Strength and conditioning professionals should be cautious when evaluating muscle recovery by peak torque, since it can lead to the repetition of a training session sooner than recommended. Copyright © 2017. Published by Elsevier Inc.
Fluence-field modulated x-ray CT using multiple aperture devices
NASA Astrophysics Data System (ADS)
Stayman, J. Webster; Mathews, Aswin; Zbijewski, Wojciech; Gang, Grace; Siewerdsen, Jeffrey; Kawamoto, Satomi; Blevis, Ira; Levinson, Reuven
2016-03-01
We introduce a novel strategy for fluence field modulation (FFM) in x-ray CT using multiple aperture devices (MADs). MAD filters permit FFM by blocking or transmitting the x-ray beam on a fine (0.1-1 mm) scale. The filters have a number of potential advantages over other beam modulation strategies including the potential for a highly compact design, modest actuation speed and acceleration requirements, and spectrally neutral filtration due to their essentially binary action. In this work, we present the underlying MAD filtration concept including a design process to achieve a specific class of FFM patterns. A set of MAD filters is fabricated using a tungsten laser sintering process and integrated into an x-ray CT test bench. A characterization of the MAD filters is conducted and compared to traditional attenuating bowtie filters and the ability to flatten the fluence profile for a 32 cm acrylic phantom is demonstrated. MAD-filtered tomographic data was acquired on the CT test bench and reconstructed without artifacts associated with the MAD filter. These initial studies suggest that MAD-based FFM is appropriate for integration in clinical CT system to create patient-specific fluence field profile and reduce radiation exposures.
Optical testbed for the LISA phasemeter
NASA Astrophysics Data System (ADS)
Schwarze, T. S.; Fernández Barranco, G.; Penkert, D.; Gerberding, O.; Heinzel, G.; Danzmann, K.
2016-05-01
The planned spaceborne gravitational wave detector LISA will allow the detection of gravitational waves at frequencies between 0.1 mHz and 1 Hz. A breadboard model for the metrology system aka the phasemeter was developed in the scope of an ESA technology development project by a collaboration between the Albert Einstein Institute, the Technical University of Denmark and the Danish industry partner Axcon Aps. It in particular provides the electronic readout of the main interferometer phases besides auxiliary functions. These include clock noise transfer, ADC pilot tone correction, inter-satellite ranging and data transfer. Besides in LISA, the phasemeter can also be applied in future satellite geodesy missions. Here we show the planning and advances in the implementation of an optical testbed for the full metrology chain. It is based on an ultra-stable hexagonal optical bench. This bench allows the generation of three unequal heterodyne beatnotes with a zero phase combination, thus providing the possibility to probe the phase readout for non-linearities in an optical three signal test. Additionally, the utilization of three independent phasemeters will allow the testing of the auxiliary functions. Once working, components can individually be replaced with flight-qualified hardware in this setup.
Laboratory errors and patient safety.
Miligy, Dawlat A
2015-01-01
Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that evaluated the encountered laboratory errors and launch the great need for universal standardization and bench marking measures to control the laboratory work.
Strain actuated aeroelastic control
NASA Technical Reports Server (NTRS)
Lazarus, Kenneth B.
1992-01-01
Viewgraphs on strain actuated aeroelastic control are presented. Topics covered include: structural and aerodynamic modeling; control law design methodology; system block diagram; adaptive wing test article; bench-top experiments; bench-top disturbance rejection: open and closed loop response; bench-top disturbance rejection: state cost versus control cost; wind tunnel experiments; wind tunnel gust alleviation: open and closed loop response at 60 mph; wind tunnel gust alleviation: state cost versus control cost at 60 mph; wind tunnel command following: open and closed loop error at 60 mph; wind tunnel flutter suppression: open loop flutter speed; and wind tunnel flutter suppression: closed loop state cost curves.
Predicting one repetition maximum equations accuracy in paralympic rowers with motor disabilities.
Schwingel, Paulo A; Porto, Yuri C; Dias, Marcelo C M; Moreira, Mônica M; Zoppi, Cláudio C
2009-05-01
Predicting one repetition maximum equations accuracy in paralympic rowers Resistance training intensity is prescribed using percentiles of the maximum strength, defined as the maximum tension generated for a muscle or muscular group. This value is found through the application of the one maximal repetition (1RM) test. One maximal repetition test demands time and still is not appropriate for some populations because of the risk it offers. In recent years, the prediction of maximal strength, through predicting equations, has been used to prevent the inconveniences of the 1RM test. The purpose of this study was to verify the accuracy of 12 1RM predicting equations for disabled rowers. Nine male paralympic rowers (7 one-leg amputated rowers and 2 cerebral paralyzed rowers; age, 30 +/- 7.9 years; height, 175.1 +/- 5.9 cm; weight, 69 +/- 13.6 kg) performed 1RM test for lying T-bar row and flat barbell bench press exercises to determine upper-body strength and leg press exercise to determine lower-body strength. One maximal repetition test was performed, and based on submaximal repetitions loads, several linear and exponential equations models were tested with regard of their accuracy. We did not find statistical differences for lying T-bar row and bench press exercises between measured and predicted 1RM values (p = 0.84 and 0.23 for lying T-bar row and flat barbell bench press, respectively); however, leg press exercise reached a high significant difference between measured and predicted values (p < 0.01). In conclusion, rowers with motor disabilities tolerate 1RM testing procedures, and predicting 1RM equations are accurate for bench press and lying T-bar row, but not for leg press, in this kind of athlete.
Upgrade of the cryogenic CERN RF test facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pirotte, O.; Benda, V.; Brunner, O.
2014-01-29
With the large number of superconducting radiofrequency (RF) cryomodules to be tested for the former LEP and the present LHC accelerator a RF test facility was erected early in the 1990’s in the largest cryogenic test facility at CERN located at Point 18. This facility consisted of four vertical test stands for single cavities and originally one and then two horizontal test benches for RF cryomodules operating at 4.5 K in saturated helium. CERN is presently working on the upgrade of its accelerator infrastructure, which requires new superconducting cavities operating below 2 K in saturated superfluid helium. Consequently, the RFmore » test facility has been renewed in order to allow efficient cavity and cryomodule tests in superfluid helium and to improve its thermal performances. The new RF test facility is described and its performances are presented.« less
STS-26 crewmembers participate in bench review at offsite Boeing Bldg
NASA Technical Reports Server (NTRS)
1988-01-01
STS-26 Discovery, Orbiter Vehicle (OV) 103, crewmembers participate in bench review at the offsite Boeing Building. Mission Specialist (MS) David C. Hilmers tests an electric razor while MS George D. Nelson reviews clipboard checklist and looks over hygiene supplies (razors, deodorants, tooth paste, etc.). Photograph was taken by Keith Meyers of the NEW YORK TIMES.
Kim, Kyung Hwan; Kim, Sun Hwa; Jung, Young Rim; Kim, Man Goo
2008-09-12
As one of the measures to improve the environment in an automobile, malodor caused by the automobile air-conditioning system evaporator was evaluated and analyzed using laboratory-scale test cooling bench. The odor was simulated with an evaporator test cooling bench equipped with an airflow controller, air temperature and relative humidity controller. To simulate the same odor characteristics that occur from automobiles, one previously used automobile air conditioner evaporator associated with unpleasant odors was selected. The odor was evaluated by trained panels and collected with aluminum polyester bags. Collected samples were analyzed by thermal desorption into a cryotrap and subsequent gas chromatographic separation, followed by simultaneous olfactometry, flame ionization detector and identified by atomic emission detection and mass spectrometry. Compounds such as alcohols, aldehydes, and organic acids were identified as responsible odor-active compounds. Gas chromatography/flame ionization detection/olfactometry combined sensory method with instrumental analysis was very effective as an odor evaluation method in an automobile air-conditioning system evaporator.
NASA Astrophysics Data System (ADS)
Bardoux, Alain; Gimenez, Thierry; Jamin, Nicolas; Seve, Frederic
2017-11-01
MTF (Modulation Transfer Frequency) of a detector is a key parameter for imagers. When image is not moving on the detector, MTF can be measured by some methods (knife edge, slanted slit,…). But with LEO satellites, image is moving on the surface of the detector, and MTF has to be measured in the same way: that is what we call "dynamic MTF". CNES (French Space Agency) has built a specific bench in order to measure dynamic MTF of detectors (CCD and CMOS), especially with component working in TDI (Time delay and integration) mode. The method is based on a moving edge, synchronized with the movement of charges inside the TDI detector. The moving part is a rotating cube, allowing a very stable movement of the image on the surface of the detector The main difficulties were: - stability of the rotating speed - synchronization between cube speed and charge transfer inside the detectors - synchronization between cube position and data acquisition. Different methods have been tested for the displacement of the knife edge: - geometrical displacement - electrical shift of the charge transfer clocks. Static MTF has been performed before dynamic measurements, in order to fix a reference measurement, Then dynamic MTF bench has been set up. The results, for a TDI CCD show a very good precision. So this bench is validated, and the dynamic MTF value of the TDI CCD is confirmed.
Comparison of concentric and eccentric bench press repetitions to failure.
Kelly, Stephen B; Brown, Lee E; Hooker, Steven P; Swan, Pamela D; Buman, Matthew P; Alvar, Brent A; Black, Laurie E
2015-04-01
Eccentric muscle actions (ECC) are characterized by muscle lengthening, despite actin-myosin crossbridge formation. Muscles acting eccentrically are capable of producing higher levels of force compared with muscles acting concentrically. The purpose of this study was to determine whether ECC bench press yields greater strength than concentric (CON) as determined by 1 repetition maximum (1RM). Additionally, a comparison was made examining differences in the number of repetitions to failure at different relative intensities of 1RM. Thirty healthy men (age = 24.63 ± 5.6 years) were tested for 1RM in CON and ECC bench press and the number of repetitions completed at 60, 70, 80, and 90% 1RM. For CON repetitions, the weight was mechanically lowered to the chest, and the participant pressed it up until the elbows were fully extended. The ECC bench press consisted of lowering a barbell from a fully extended elbow position to the chest in a continuous controlled manner for 3 seconds as determined by electronic metronome. Paired t-tests showed that ECC 1RM (115.99 ± 31.08 kg) was significantly (p ≤ 0.05) greater than CON 1RM (93.56 ± 26.56 kg), and the number of repetitions completed at 90% 1RM was significantly (p ≤ 0.05) greater in ECC (7.67 ± 3.24) as compared with CON (4.57 ± 2.21). There were no significant differences in number of completed repetitions during CON and ECC bench press at 60, 70, and 80% 1RM. These data indicate that ECC actions yield increased force capabilities (∼120%) as compared with CON in the bench press and may be less prone to fatigue, especially at higher intensities. These differences suggest a need to develop unique strategies for training eccentrically.
Beck, Travis W; Housh, Terry J; Malek, Moh H; Mielke, Michelle; Hendrix, Russell
2008-09-01
The purpose of the present study was to examine the acute effects of a caffeine-containing supplement (SUPP) on one-repetition maximum (1-RM) bench press strength and time to running exhaustion (TRE) at a velocity that corresponded to 85% of the peak oxygen uptake ([latin capital V with dot above]O2peak). The study used a double-blinded, placebo-controlled, crossover design. Thirty-one men (mean +/- SD age = 23.0 +/- 2.6 years) were randomly assigned to take either the SUPP or placebo (PLAC) first. The SUPP contained 201 mg of caffeine, and the PLAC was microcrystalline cellulose. All subjects were tested for 1-RM bench press strength and TRE at 45 minutes after taking either the SUPP or PLAC. After 1 week of rest, the subjects returned to the laboratory and ingested the opposite substance (SUPP or PLAC) from what was taken during the previous visit. The 1-RM bench press and TRE tests were then performed in the same manner as before. The results indicated that the SUPP had no effect on 1-RM bench press strength or TRE at 85% [latin capital V with dot above]O2peak. It is possible that the acute effects of caffeine are affected by differences in training status and/or the relative intensity of the exercise task. Future studies should examine these issues, in addition to testing the acute effects of various caffeine doses on performance during maximal strength, power, and aerobic activities. These findings do not, however, support the use of caffeine as an ergogenic aid in untrained to moderately trained individuals.
Ritti-Dias, Raphael Mendes; Avelar, Ademar; Salvador, Emanuel Péricles; Cyrino, Edilson Serpeloni
2011-05-01
The 1-repetition maximum test (1RM) has been widely used to assess maximal strength. However, to improve accuracy in assessing maximal strength, several sessions of the 1RM test are recommended. The aim of this study was to analyze the influence of previous resistance training experience on the reliability of 1RM test. Thirty men were assigned to the following 2 groups according to their previous resistance training experience: no previous resistance training experience (NOEXP) and more than 24 months of resistance training experience (EXP). All subjects performed the 1RM tests in bench press and squat in 4 sessions on distinct days. There was a significant session × group effect in bench press (F = 3.09; p < 0.03) and squat (F = 2.76; p < 0.05) showing that only the NOEXP increased maximal strength between the sessions. Significant increases (p < 0.05) in maximal strength occurred in the NOEXP between session 1 and the other sessions in bench press (session 1 vs. 2 = +3.8%; session 1 vs. 3 = +7.4%; session 1 vs. 4 = +10.1%), and squat (session 1 vs. 2 = +7.6%; session 1 vs. 3 = +10.1%; session 1 vs. 4 = +11.2%). Moreover, in bench press, maximal strength in sessions 3 and 4 were significantly higher than in session 2. The results of the present study suggest that the reliability of the 1RM test is influenced by the subject's previous experience in resistance training. Subjects without experience in resistance training require more practice and familiarization and show greater increases in maximal strength between sessions than subjects with previous experience in resistance training.
Chidley, Matthew D; Carlson, Kristen D; Richards-Kortum, Rebecca R; Descour, Michael R
2006-04-10
The design, analysis, assembly methods, and optical-bench test results for a miniature injection-molded plastic objective lens used in a fiber-optic confocal reflectance microscope are presented. The five-lens plastic objective was tested as a stand-alone optical system before its integration into a confocal microscope for in vivo imaging of cells and tissue. Changing the spacing and rotation of the individual optical elements can compensate for fabrication inaccuracies and improve performance. The system performance of the miniature objective lens is measured by use of an industry-accepted slanted-edge modulation transfer function (MTF) metric. An estimated Strehl ratio of 0.61 and a MTF value of 0.66 at the fiber-optic bundle Nyquist frequency have been obtained. The optical bench testing system is configured to permit interactive optical alignment during testing to optimize performance. These results are part of an effort to demonstrate the manufacturability of low-cost, high-performance biomedical optics for high-resolution in vivo imaging. Disposable endoscopic microscope objectives could help in vivo confocal microscopy technology mature to permit wide-scale clinical screening and detection of early cancers and precancerous lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adu-Wusu, K; Paul Burket, P
2009-03-31
Wet Air Oxidation (WAO) is one of the two technologies being considered for the destruction of Tetraphenylborate (TPB) in Tank 48H. Batch bench-scale autoclave testing with radioactive (actual) Tank 48H waste is among the tests required in the WAO Technology Maturation Plan. The goal of the autoclave testing is to validate that the simulant being used for extensive WAO vendor testing adequately represents the Tank 48H waste. The test objective was to demonstrate comparable test results when running simulated waste and real waste under similar test conditions. Specifically: (1) Confirm the TPB destruction efficiency and rate (same reaction times) obtainedmore » from comparable simulant tests, (2) Determine the destruction efficiency of other organics including biphenyl, (3) Identify and quantify the reaction byproducts, and (4) Determine off-gas composition. Batch bench-scale stirred autoclave tests were conducted with simulated and actual Tank 48H wastes at SRNL. Experimental conditions were chosen based on continuous-flow pilot-scale simulant testing performed at Siemens Water Technologies Corporation (SWT) in Rothschild, Wisconsin. The following items were demonstrated as a result of this testing. (1) Tetraphenylborate was destroyed to below detection limits during the 1-hour reaction time at 280 C. Destruction efficiency of TPB was > 99.997%. (2) Other organics (TPB associated compounds), except biphenyl, were destroyed to below their respective detection limits. Biphenyl was partially destroyed in the process, mainly due to its propensity to reside in the vapor phase during the WAO reaction. Biphenyl is expected to be removed in the gas phase during the actual process, which is a continuous-flow system. (3) Reaction byproducts, remnants of MST, and the PUREX sludge, were characterized in this work. Radioactive species, such as Pu, Sr-90 and Cs-137 were quantified in the filtrate and slurry samples. Notably, Cs-137, boron and potassium were shown as soluble as a result of the WAO reaction. (4) Off-gas composition was measured in the resulting gas phase from the reaction. Benzene and hydrogen were formed during the reaction, but they were reasonably low in the off-gas at 0.096 and 0.0063 vol% respectively. Considering the consistency in replicating similar test results with simulated waste and Tank 48H waste under similar test conditions, the results confirm the validity of the simulant for other WAO test conditions.« less
Creatine supplementation prevents acute strength loss induced by concurrent exercise.
de Salles Painelli, Vítor; Alves, Victor Tavares; Ugrinowitsch, Carlos; Benatti, Fabiana Braga; Artioli, Guilherme Giannini; Lancha, Antonio Herbert; Gualano, Bruno; Roschel, Hamilton
2014-08-01
To investigate the effect of creatine (CR) supplementation on the acute interference induced by aerobic exercise on subsequent maximum dynamic strength (1RM) and strength endurance (SE, total number of repetitions) performance. Thirty-two recreationally strength-trained men were submitted to a graded exercise test to determine maximal oxygen consumption (VO2max: 41.56 ± 5.24 ml kg(-1) min(-1)), anaerobic threshold velocity (ATv: 8.3 ± 1.18 km h(-1)), and baseline performance (control) on the 1RM and SE (4 × 80 % 1RM to failure) tests. After the control tests, participants were randomly assigned to either a CR (20 g day(-1) for 7 days followed by 5 g day(-1) throughout the study) or a placebo (PL-dextrose) group, and then completed 4 experimental sessions, consisting of a 5-km run on a treadmill either continuously (90 % ATv) or intermittently (1:1 min at vVO2max) followed by either a leg- or bench-press SE/1RM test. CR was able to maintain the leg-press SE performance after the intermittent aerobic exercise when compared with C (p > 0.05). On the other hand, the PL group showed a significant decrease in leg-press SE (p ≤ 0.05). CR supplementation significantly increased bench-press SE after both aerobic exercise modes, while the bench-press SE was not affected by either mode of aerobic exercise in the PL group. Although small increases in 1RM were observed after either continuous (bench press and leg press) or intermittent (bench press) aerobic exercise in the CR group, they were within the range of variability of the measurement. The PL group only maintained their 1RM. In conclusion, the acute interference effect on strength performance observed in concurrent exercise may be counteracted by CR supplementation.
Uribe, Brandon P; Coburn, Jared W; Brown, Lee E; Judelson, Daniel A; Khamoui, Andy V; Nguyen, Diamond
2010-04-01
The aim of this study was to examine the effects of a stable surface (bench) vs. an unstable surface (Swiss ball) on muscle activation when performing the dumbbell chest press and shoulder press. Sixteen healthy men (24.19 +/- 2.17 years) performed 1 repetition maximum (1RM) tests for the chest press and shoulder press on a stable surface. A minimum of 48 hours post 1RM, subjects returned to perform 3 consecutive repetitions each of the chest press and shoulder press at 80% 1RM under 4 different randomized conditions (chest press on bench, chest press on Swiss ball, shoulder press on bench, shoulder press on Swiss ball). Electromyography was used to assess muscle activation of the anterior deltoid, pectoralis major, and rectus abdominus. The results revealed no significant difference in muscle activation between surface types for either exercise. This suggests that using an unstable surface neither improves nor impairs muscle activation under the current conditions. Coaches and other practitioners can expect similar muscle activation when using a Swiss ball vs. a bench.
Hartley, T F
2010-01-01
The aim of this study was to design an audit questionnaire that focuses on the management of the technical activities in a Diagnostic Pathology Laboratory. The ISO 15189 Standard is written in such a way that it continually moves back and forth from topics where the auditor needs to question bench level staff, to topics where the auditor needs to question Technical Management Staff. This makes for a disjointed audit process - both Bench Staff and Technical Managers are repeatedly interrupted. The solution was to do a clause by clause analysis of the Standard and assign the major responsibility for the compliance to each clause to either Technical Managers or Bench Staff. The Clauses were then grouped under four topic headings regardless of whether they were a Section 4 or Section 5 Clause. Two questionnaires have emerged - the one described in this work and one directed primarily towards the activities of bench staff. There are 95 questions and it takes approximately two hours to complete.
[Data supporting quality circle management of inpatient depression treatment].
Brand, S; Härter, M; Sitta, P; van Calker, D; Menke, R; Heindl, A; Herold, K; Kudling, R; Luckhaus, C; Rupprecht, U; Sanner, Dirk; Schmitz, D; Schramm, E; Berger, M; Gaebel, W; Schneider, F
2005-07-01
Several quality assurance initiatives in health care have been undertaken during the past years. The next step consists of systematically combining single initiatives in order to built up a strategic quality management. In a German multicenter study, the quality of inpatient depression treatment was measured in ten psychiatric hospitals. Half of the hospitals received comparative feedback on their individual results in comparison to the other hospitals (bench marking). Those bench markings were used by each hospital as a statistic basis for in-house quality work, to improve the quality of depression treatment. According to hospital differences concerning procedure and outcome, different goals were chosen. There were also differences with respect to structural characteristics, strategies, and outcome. The feedback from participants about data-based quality circles in general and the availability of bench-marking data was positive. The necessity of carefully choosing quality circle members and professional moderation became obvious. Data-based quality circles including bench-marking have proven to be useful for quality management in inpatient depression care.
NASA Astrophysics Data System (ADS)
Bourgois, R.; Hamy, A. L.; Pourcelot, P.
2017-10-01
SUN is a test bench developed by Safran Reosc to measure spherical or aspherical surface errors of litho-grade lenses with sub-nanometer accuracy. SUN provides full aperture high resolution interferometric measurements. Measurements are performed at the center of curvature using high precision transmission sphere (TS), and Computer Generated Holograms (CGH) for aspheres, in order to light the surface at normal incidence. SUN can measure lenses with diameter up to 350mm and a radius of curvature varying from 60 to 3000 mm.
NASA Astrophysics Data System (ADS)
Patil, Riya Raghuvir
Networks of communicating agents require distributed algorithms for a variety of tasks in the field of network analysis and control. For applications such as swarms of autonomous vehicles, ad hoc and wireless sensor networks, and such military and civilian applications as exploring and patrolling a robust autonomous system that uses a distributed algorithm for selfpartitioning can be significantly helpful. A single team of autonomous vehicles in a field may need to self-dissemble into multiple teams, conducive to completing multiple control tasks. Moreover, because communicating agents are subject to changes, namely, addition or failure of an agent or link, a distributed or decentralized algorithm is favorable over having a central agent. A framework to help with the study of self-partitioning of such multi agent systems that have most basic mobility model not only saves our time in conception but also gives us a cost effective prototype without negotiating the physical realization of the proposed idea. In this thesis I present my work on the implementation of a flexible and distributed stochastic partitioning algorithm on the LegoRTM Mindstorms' NXT on a graphical programming platform using National Instruments' LabVIEW(TM) forming a team of communicating agents via NXT-Bee radio module. We single out mobility, communication and self-partition as the core elements of the work. The goal is to randomly explore a precinct for reference sites. Agents who have discovered the reference sites announce their target acquisition to form a network formed based upon the distance of each agent with the other wherein the self-partitioning begins to find an optimal partition. Further, to illustrate the work, an experimental test-bench of five Lego NXT robots is presented.
The "bench-presser's shoulder": an overuse insertional tendinopathy of the pectoralis minor muscle.
Bhatia, Deepak N; de Beer, Joe F; van Rooyen, Karin S; Lam, Francis; du Toit, Donald F
2007-08-01
Tendinopathies of the rotator cuff muscles, biceps tendon and pectoralis major muscle are common causes of shoulder pain in athletes. Overuse insertional tendinopathy of pectoralis minor is a previously undescribed cause of shoulder pain in weightlifters/sportsmen. To describe the clinical features, diagnostic tests and results of an overuse insertional tendinopathy of the pectoralis minor muscle. To also present a new technique of ultrasonographic evaluation and injection of the pectoralis minor muscle/tendon based on use of standard anatomical landmarks (subscapularis, coracoid process and axillary artery) as stepwise reference points for ultrasonographic orientation. Between 2005 and 2006, seven sportsmen presenting with this condition were diagnosed and treated at the Cape Shoulder Institute, Cape Town, South Africa. In five patients, the initiating and aggravating factor was performance of the bench-press exercise (hence the term "bench-presser's shoulder"). Medial juxta-coracoid tenderness, a painful active-contraction test and bench-press manoeuvre, and decrease in pain after ultrasound-guided injection of a local anaesthetic agent into the enthesis, in the absence of any other clinically/radiologically apparent pathology, were diagnostic of pectoralis minor insertional tendinopathy. All seven patients were successfully treated with a single ultrasound-guided injection of a corticosteroid into the enthesis of pectoralis minor followed by a period of rest and stretching exercises. This study describes the clinical features and management of pectoralis minor insertional tendinopathy, secondary to the bench-press type of weightlifting. A new pain site-based classification of shoulder pathology in weightlifters is suggested.
Dugdale, James H; Hunter, Angus; Di Virgilio, Thomas; Macgregor, Lewis J; Hamilton, D Lee
2017-02-13
This study examined the acute effects of the 'Slingshot' on bench-press performance, prime-mover surface electromyographic (sEMG) amplitude, and barbell velocity during maximal and submaximal bench-pressing in competitive male powerlifters. Fifteen male powerlifters (mean ± SD age: 27.05 ± 5.94 years; mass: 94.15kg; 1RM bench-press: 139.7 ± 16.79kg) participated in the study. Bench-press strength, average barbell velocity, and sEMG amplitude of the prime mover muscles (triceps brachii, pectoralis major and anterior deltoid) were measured during two conditions; 'Raw' (without use of any assistance) and 'Slingshot' [using the 'Slingshot' to perform both the weight achieved during 'Raw' 1RM testing (Raw max/SS), and absolute 1RM using the 'Slingshot' (SS)]. The results showed that the 'Slingshot' significantly increased bench press 1RM performance by a mean ± SD of 20.67kg ± 3.4kg. Barbell velocity and stick point analysis indicate that this improvement is likely driven by an increase in peak and pre-stick barbell velocity as triceps RMS was lower throughout all rep max phases with the 'Slingshot'. The 'Slingshot' also caused reductions in RMS, specifically of the triceps at all rep ranges but barbell velocity was better maintained in the last reps of all sets. These data indicate that the 'Slingshot' specifically de-loaded the triceps muscle throughout all rep ranges and provide assistance to maintaining barbell velocity under fatigue during later repetitions of multiple-repetition sets. The 'Slingshot' training aid could therefore be used in de-load phases of bench press training or as an over-reaching and velocity training aid.
NASA Technical Reports Server (NTRS)
Frady, Greg; Smaolloey, Kurt; LaVerde, Bruce; Bishop, Jim
2004-01-01
The paper will discuss practical and analytical findings of a test program conducted to assist engineers in determining which analytical strain fields are most appropriate to describe the crack initiating and crack propagating stresses in thin walled cylindrical hardware that serves as part of the Space Shuttle Main Engine's fuel system. In service the hardware is excited by fluctuating dynamic pressures in a cryogenic fuel that arise from turbulent flow/pump cavitation. A bench test using a simplified system was conducted using acoustic energy in air to excite the test articles. Strain measurements were used to reveal response characteristics of two Flowliner test articles that are assembled as a pair when installed in the engine feed system.
Changes in technique and efficiency after high-intensity exercise in cross-country skiers.
Åsan Grasaas, Christina; Ettema, Gertjan; Hegge, Ann Magdalen; Skovereng, Knut; Sandbakk, Øyvind
2014-01-01
This study investigated changes in technique and efficiency after high-intensity exercise to exhaustion in elite cross-country skiers. Twelve elite male skiers completed 4 min submaximal exercise before and after a high-intensity incremental test to exhaustion with the G3 skating technique on a 5% inclined roller-ski treadmill. Kinematics and kinetics were monitored by instrumented roller skis, work rate was calculated as power against roller friction and gravity, aerobic metabolic cost was determined from gas exchange, and blood lactate values indicated the anaerobic contribution. Gross efficiency was the work rate divided by aerobic metabolic rate. A recovery period of 10 min between the incremental test and the posttest was included to allow the metabolic values to return to baseline. Changes in neuromuscular fatigue in upper and lower limbs before and after the incremental test were indicated by peak power in concentric bench press and squat-jump height. From pretest to posttest, cycle length decreased and cycle rate increased by approximately 5% (P < 0.001), whereas the amount of ski forces did not change significantly. Oxygen uptake increased by 4%, and gross efficiency decreased from 15.5% ± 0.7% to 15.2% ± 0.5% from pretest to posttest (both P < .02). Correspondingly, blood lactate concentration increased from 2.4 ± 1.0 to 6.2 ± 2.5 mmol/L (P < .001). Bench-press and squat-jump performance remained unaltered. Elite cross-country skiers demonstrated a less efficient technique and shorter cycle length during submaximal roller-ski skating after high-intensity exercise. However, there were no changes in ski forces or peak power in the upper and lower limbs that could explain these differences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Mulled Coal process was developed as a means of overcoming the adverse handling characteristics of wet fine coal without thermal drying. The process involves the addition of a low cost, harmless reagent to wet fine coal using off-the-shelf mixing equipment. Based on laboratory- and bench-scale testing, Mulled coal can be stored, shipped, and burned without causing any of the plugging, pasting, carryback and freezing problems normally associated with wet coal. On the other hand, Mulled Coal does not cause the fugitive and airborne dust problems normally associated with thermally dried coal. The objectives of this project are to demonstratemore » that: the Mulled Coal process, which has been proved to work on a wide range of wet fine coals at bench scale, will work equally well on a continuous basis, producing consistent quality, and at a convincing rate of production in a commercial coal preparation plant; the wet product from a fine coal cleaning circuit can be converted to a solid fuel form for ease of handling and cost savings in storage and rail car transportation; and a wet fine coal product thus converted to a solid fuel form, can be stored, shipped, and burned with conventional fuel handling, transportation, and combustion systems.« less
A fuel cell energy storage system concept for the Space Station Freedom Extravehicular Mobility Unit
NASA Technical Reports Server (NTRS)
Adlhart, Otto J.; Rosso, Matthew J., Jr.; Marmolejo, Jose
1989-01-01
An update is given on work to design and build a Fuel Cell Energy Storage System (FCESS) bench-tested unit for the Space Station Freedom Extravehicular Mobility Unit (EMU). Fueled by oxygen and hydride-stored hydrogen, the FCESS is being considered as an alternative to the EMU zinc-silver oxide battery. Superior cycle life and quick recharge are the main attributes of FCESS. The design and performance of a nonventing, 28 V, 34 Ahr system with 7 amp rating are discussed.
A fuel cell energy storage system concept for the Space Station Freedom Extravehicular Mobility Unit
NASA Astrophysics Data System (ADS)
Adlhart, Otto J.; Rosso, Matthew J., Jr.; Marmolejo, Jose
1989-03-01
An update is given on work to design and build a Fuel Cell Energy Storage System (FCESS) bench-tested unit for the Space Station Freedom Extravehicular Mobility Unit (EMU). Fueled by oxygen and hydride-stored hydrogen, the FCESS is being considered as an alternative to the EMU zinc-silver oxide battery. Superior cycle life and quick recharge are the main attributes of FCESS. The design and performance of a nonventing, 28 V, 34 Ahr system with 7 amp rating are discussed.
Computational test bench and flow chart for wavefront sensors
NASA Astrophysics Data System (ADS)
Abecassis, Úrsula V.; de Lima Monteiro, Davies W.; Salles, Luciana P.; Stanigher, Rafaela; Borges, Euller
2014-05-01
The wavefront reconstruction diagram has come to supply the need in literature of an ampler vision over the many methods and optronic devices used for the reconstruction of wavefronts and to show the existing interactions between those. A computational platform has been developed using the diagram's orientation for the taking of decision over the best technique and the photo sensible and electronic structures to be implemented. This work will be directed to an ophthalmological application in the development of an instrument of help for the diagnosis of optical aberrations of the human eye.
Bench-scale research in biomass liquefaction in support of the Albany, Oregon experimental facility
NASA Astrophysics Data System (ADS)
Elliott, D. C.
1981-03-01
The liquefaction of solid materials (wood, newsprint, animal manure) by beating to produce useful liquid fuels was investigated. Highlights of work performed include: (1) catalyst mechanism studies; (2) analytical reports on TR8 and TR9 product oils; (3) liquid chromatography/mass spectroscopy analysis of wood oil; (4) batch conversion tests on bottom material; (5) vapor pressure studies; and (6) product evaluation. It was confirmed that the key process parameters and the effects of varying operating conditions are in support of biomass liquefaction.
Adaptive antenna arrays for satellite communication
NASA Technical Reports Server (NTRS)
Gupta, Inder J.
1989-01-01
The feasibility of using adaptive antenna arrays to provide interference protection in satellite communications was studied. The feedback loops as well as the sample matric inversion (SMI) algorithm for weight control were studied. Appropriate modifications in the two were made to achieve the required interference suppression. An experimental system was built to test the modified feedback loops and the modified SMI algorithm. The performance of the experimental system was evaluated using bench generated signals and signals received from TVRO geosynchronous satellites. A summary of results is given. Some suggestions for future work are also presented.
Characterization of Fernald Silo 3 Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langton, C.A.
This report summarizes characterization results for uranium residues from the Fernald Environmental Management Project (FEMP) Operable Unit (OU-4). These residues are currently stored in a one-million-gallon concrete silo, Silo 3, at the DOE Fernald Site, Ohio. Characterization of the Silo 3 waste is the first part of a three part study requested by Rocky Mountain Remedial Services (RMRS) through a Work for others Agreement, WFO-00-007, between the Westinghouse Savannah River Company (WSRC) and RMRS. Parts 2 and 3 of this effort include bench- and pilot-scale testing.
Bench Scale Development and Testing of Aerogel Sorbents for CO 2 Capture Final Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Begag, Redouane
The primary objective of this project was scaling up and evaluating a novel Amine Functionalized Aerogel (AFA) sorbent in a bench scale fluidized bed reactor. The project team (Aspen Aerogels, University of Akron, ADA-ES, and Longtail Consulting) has carried out numerous tests and optimization studies to demonstrate the CO 2 capture performance of the AFA sorbent in all its forms: powder, pellet, and bead. The CO 2 capture target performance of the AFA sorbent (all forms) were set at > 12 wt.% and > 6 wt.% for total and working CO 2 capacity, respectively (@ 40 °C adsorption / 100more » – 120 °C desorption). The optimized AFA powders outperformed the performance targets by more than 30%, for the total CO 2 capacity (14 - 20 wt.%), and an average of 10 % more for working CO 2 capacity (6.6 – 7.0 wt.%, and could be as high as 9.6 wt. % when desorbed at 120 °C). The University of Akron developed binder formulations, pellet production methods, and post treatment technology for increased resistance to attrition and flue gas contaminants. In pellet form the AFA total CO 2 capacity was ~ 12 wt.% (over 85% capacity retention of that of the powder), and there was less than 13% degradation in CO 2 capture capacity after 20 cycles in the presence of 40 ppm SO 2. ADA-ES assessed the performance of the AFA powder, pellet, and bead by analyzing sorption isotherms, water uptake analysis, cycling stability, jet cup attrition and crush tests. At bench scale, the hydrodynamic and heat transfer properties of the AFA sorbent pellet in fluidized bed conditions were evaluated at Particulate Solid Research, Inc. (PSRI). After the process design requirements were completed, by Longtail Consulting LLC, a techno-economic analysis was achieved using guidance from The National Energy Technology Laboratory (NETL) report. This report provides the necessary framework to estimate costs for a temperature swing post combustion CO 2 capture process using a bituminous coal fired, super-critical steam cycle power plant producing 550 MWe net generation with 90% CO 2 capture using a methylethylamine (MEA) solvent. Using the NETL report as guidance, the designed CO 2 capture system was analyzed on a cost basis to determine relative cost estimates between the benchmark MEA system and the AFA sorbent system.« less
Comportement dynamique d'alliages a memoire de forme et application aux composites-AMF
NASA Astrophysics Data System (ADS)
de Santis, Silvio
Meeting current industrial, governmental and international standards regarding vibration and noise levels is a challenging task facing many engineers. These specifications are present in just about all fields of engineering, from aerospace to marine transportation, from automotive to railway transportation, from computer equipment to industrial working environments. An appropriate use of the remarkable properties of high damping metals (HIDAMETS) and shape memory alloy (SMA) reinforced composites emerges as a possible solution to these problems. Among many obstacles to overcome in developing such a technology, the implementation of reliable and adequate characterization techniques to determine dynamic properties of these materials appears to be of prime importance. The research efforts presented in this thesis are aimed at developing advanced techniques to characterize the dynamic behavior of HIDAMETS and SMA reinforced composites. These characterization results lead to the enhancement of numerical (finite element) and/or analytical methods for the simulation of dynamic responses of structures made of these materials. In particular, the research work has focused on three themes: the numerical and experimental validation of applying a characterization procedure developed for traditional composites to SMA reinforced composites; the development of a test bench for uniaxial hysteresis characterization of HIDAMETS in the medium frequency range; the hysteresis characterization and modeling of manganese copper (MnCu) and nickel titanium samples. The results obtained in the course of these efforts show that the characterization technique developed for traditional composites at the University of Brussels is sufficiently precise to successfully predict natural frequencies of complex SMA reinforced composite structures. Using the characterization to predict structural damping ratios, we observe a bias error in the prediction with respect to experimental results although the relative values between modes are consistent. Regarding the development of the test bench for uniaxial hysteresis characterization of HIDAMETS, results suggest that with the introduction of a few minor enhancements and with particular experimental precautions, the test bench can play an important role in characterizing HIDAMETS dynamic properties at various frequencies and strain amplitudes and in understanding micro mechanical mechanisms responsible for energy dissipation. Finally, uniaxial hysteresis loops and related parameters have been obtained with MnCu and NiTi samples. A material model based on dual kriging interpolation that expresses the tangent stiffness along these hysteresis loops as a function of strain and strain amplitude has also been developed.
Co-Production of Electricity and Hydrogen Using a Novel Iron-based Catalyst
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hilaly, Ahmad; Georgas, Adam; Leboreiro, Jose
2011-09-30
The primary objective of this project was to develop a hydrogen production technology for gasification applications based on a circulating fluid-bed reactor and an attrition resistant iron catalyst. The work towards achieving this objective consisted of three key activities: Development of an iron-based catalyst suitable for a circulating fluid-bed reactor; Design, construction, and operation of a bench-scale circulating fluid-bed reactor system for hydrogen production; Techno-economic analysis of the steam-iron and the pressure swing adsorption hydrogen production processes. This report describes the work completed in each of these activities during this project. The catalyst development and testing program prepared and iron-basedmore » catalysts using different support and promoters to identify catalysts that had sufficient activity for cyclic reduction with syngas and steam oxidation and attrition resistance to enable use in a circulating fluid-bed reactor system. The best performing catalyst from this catalyst development program was produced by a commercial catalyst toll manufacturer to support the bench-scale testing activities. The reactor testing systems used during material development evaluated catalysts in a single fluid-bed reactor by cycling between reduction with syngas and oxidation with steam. The prototype SIP reactor system (PSRS) consisted of two circulating fluid-bed reactors with the iron catalyst being transferred between the two reactors. This design enabled demonstration of the technical feasibility of the combination of the circulating fluid-bed reactor system and the iron-based catalyst for commercial hydrogen production. The specific activities associated with this bench-scale circulating fluid-bed reactor systems that were completed in this project included design, construction, commissioning, and operation. The experimental portion of this project focused on technical demonstration of the performance of an iron-based catalyst and a circulating fluid-bed reactor system for hydrogen production. Although a technology can be technically feasible, successful commercial deployment also requires that a technology offer an economic advantage over existing commercial technologies. To effective estimate the economics of this steam-iron process, a techno-economic analysis of this steam iron process and a commercial pressure swing adsorption process were completed. The results from this analysis described in this report show the economic potential of the steam iron process for integration with a gasification plant for coproduction of hydrogen and electricity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heldebrant, David J
PNNL, Fluor Corporation and Queens University (Kingston, ON) successfully completed a three year comprehensive study of the CO2BOL water-lean solvent platform with Polarity Swing Assisted Regeneration (PSAR). This study encompassed solvent synthesis, characterization, environmental toxicology, physical, thermodynamic and kinetic property measurements, Aspen Plus™ modeling and bench-scale testing of a candidate CO2BOL solvent molecule. Key Program Findings The key program findings are summarized as follows: • PSAR favorably reduced stripper duties and reboiler temperatures with little/no impact to absorption column • >90% CO2 capture was achievable at reasonable liquid-gas ratios in the absorber • High rich solvent viscosities (up to 600more » cP) were successfully demonstrated in the bench-scale system. However, the projected impacts of high viscosity to capital cost and operational limits compromised the other levelized cost of electricity benefits. • Low thermal conductivity of organics significantly increased the required cross exchanger surface area, and potentially other heat exchange surfaces. • CO2BOL had low evaporative losses during bench-scale testing • There was no evidence of foaming during bench scale testing • Current CO2BOL formulation costs project to be $35/kg • Ecotoxicity (Water Daphnia) was comparable between CO2BOL and MEA (169.47 versus 103.63 mg/L) • Full dehydration of the flue gas was determined to not be economically feasible. However, modest refrigeration (13 MW for the 550 MW reference system) was determined to be potentially economically feasible, and still produce a water-lean condition for the CO2BOLs (5 wt% steady-state water loading). • CO2BOLs testing with 5 wt% water loading did not compromise anhydrous performance behavior, and showed actual enhancement of CO2 capture performance. • Mass transfer of CO2BOLs was not greatly impeded by viscosity • Facile separation of antisolvent from lean CO2BOL was demonstrated on the bench cart • No measurable solvent degradation was observed over 4 months of testing – even with 5 wt% water present« less
Performance evaluation of an automotive thermoelectric generator
NASA Astrophysics Data System (ADS)
Dubitsky, Andrei O.
Around 40% of the total fuel energy in typical internal combustion engines (ICEs) is rejected to the environment in the form of exhaust gas waste heat. Efficient recovery of this waste heat in automobiles can promise a fuel economy improvement of 5%. The thermal energy can be harvested through thermoelectric generators (TEGs) utilizing the Seebeck effect. In the present work, a versatile test bench has been designed and built in order to simulate conditions found on test vehicles. This allows experimental performance evaluation and model validation of automotive thermoelectric generators. An electrically heated exhaust gas circuit and a circulator based coolant loop enable integrated system testing of hot and cold side heat exchangers, thermoelectric modules (TEMs), and thermal interface materials at various scales. A transient thermal model of the coolant loop was created in order to design a system which can maintain constant coolant temperature under variable heat input. Additionally, as electrical heaters cannot match the transient response of an ICE, modelling was completed in order to design a relaxed exhaust flow and temperature history utilizing the system thermal lag. This profile reduced required heating power and gas flow rates by over 50%. The test bench was used to evaluate a DOE/GM initial prototype automotive TEG and validate analytical performance models. The maximum electrical power generation was found to be 54 W with a thermal conversion efficiency of 1.8%. It has been found that thermal interface management is critical for achieving maximum system performance, with novel designs being considered for further improvement.
Gold, Michael R; Kanal, Emanuel; Schwitter, Juerg; Sommer, Torsten; Yoon, Hyun; Ellingson, Michael; Landborg, Lynn; Bratten, Tara
2015-03-01
Many patients with an implantable cardioverter-defibrillator (ICD) have indications for magnetic resonance imaging (MRI). However, MRI is generally contraindicated in ICD patients because of potential risks from hazardous interactions between the MRI and ICD system. The purpose of this study was to use preclinical computer modeling, animal studies, and bench and scanner testing to demonstrate the safety of an ICD system developed for 1.5-T whole-body MRI. MRI hazards were assessed and mitigated using multiple approaches: design decisions to increase safety and reliability, modeling and simulation to quantify clinical MRI exposure levels, animal studies to quantify the physiologic effects of MRI exposure, and bench testing to evaluate safety margin. Modeling estimated the incidence of a chronic change in pacing capture threshold >0.5 V and 1.0 V to be less than 1 in 160,000 and less than 1 in 1,000,000 cases, respectively. Modeling also estimated the incidence of unintended cardiac stimulation to occur in less than 1 in 1,000,000 cases. Animal studies demonstrated no delay in ventricular fibrillation detection and no reduction in ventricular fibrillation amplitude at clinical MRI exposure levels, even with multiple exposures. Bench and scanner testing demonstrated performance and safety against all other MRI-induced hazards. A preclinical strategy that includes comprehensive computer modeling, animal studies, and bench and scanner testing predicts that an ICD system developed for the magnetic resonance environment is safe and poses very low risks when exposed to 1.5-T normal operating mode whole-body MRI. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Direct liquefaction proof-of-concept program. Finaltopical report, Bench Run 4 (227-95)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Comolli, A.G.; Pradhan, V.R.; Lee, T.L.K.
This report presents the results of bench-scale work, Bench Run PB-04, conducted under the DOE Proof of Concept-Bench Option Program in direct coal liquefaction at Hydrocarbon Technologies, Inc. in Lawrenceville, New Jersey. The Bench Run PB-04 was the fifth of the nine runs planned in the POC Bench Option Contract between the U.S. DOE and Hydrocarbon Technologies, Inc. Bench Run PB-04 had multiple goals. These included the evaluation of the effects of dispersed slurry catalyst system on the performance of direct liquefaction of a subbituminous Wyoming Black Thunder mine coal under extinction recycle (454{degrees}C+ recycle) condition; another goal was tomore » investigate the effects of the combined processing of automobile shredder residue (auto-fluff) with coal and other organic waste materials. PB-04 employed a two-stage, back-mixed, slurry reactor system with an interstage V/L separator and an in-line fixed-bed hydrotreater. The HTI`s newly modified P/Fe catalyst was very effective for direct liquefaction and coprocessing of Black Thunder mine subbituminous coal with Hondo resid and auto-fluff; during `coal-only` liquefaction mode, over 93% maf coal conversion was obtained with about 90% residuum conversion and as high as 67% light distillate (C{sub 4}-975 F) yield, while during `coprocessing` mode of operation, distillate yields varied between 58 and 69%; the residuum conversions varied between 74 and 89% maf. Overall, it is concluded, based upon the yield data available from PB-04, that auto-effective as MSW plastics in improving coal hydroconversion process performance. Auto-fluff did not increase light distillate yields nor decrease light gas make and chemical hydrogen consumption in coal liquefaction, as was observed to occur with MSW plastics.« less
Optical Bench for LISA-like missions
NASA Astrophysics Data System (ADS)
Mueller, Guido
The detection of B-modes in the μ-Wave background has rattled the scientific community and further enhanced the large scientific interest in gravitational waves and gravitational wave astronomy. The first direct detection of gravitational waves by Advanced LIGO and maybe also by pulsar timing arrays in the second half of this decade will be another watershed event which will start a new era in astronomy and astrophysics. However, the holy grail of gravitational wave astronomy will be opened by a LISA-like mission. Only space provides the environment that allows to cover the signal-rich mHz frequency range where we expect to see gravitational waves from massive black hole mergers, compact galactic binaries, and many other sources. All mature concepts use laser interferometry between free falling test masses separated by millions of km. The central piece in all these concepts is a stable optical bench which is used to prepare and exchange the laser beams between the different arms. It has always been assumed that the base material for the optical bench has to be one of the ultra-low expansion glasses such as Zerodur or ULE to meet the pm/#Hz stability requirements. This very conservative approach was a reflection of the state-of-the-art in frequency stabilization experiments which used optical reference cavities in the early ‘90s. It is not surprising that the LISA pathfinder (LPF) uses also an all Zerodur bench where each optical component is precision bonded to the bench using hydroxide bonding, a nonreversible bonding technique. The manufacturing of this bench was a very time consuming one-mirror-a-day effort and was one of the highest risk items in terms of schedule and cost. The original LISA design uses the same approach except that the LISA bench is far more complex than the LPF bench and manufacturing of the required 10+ benches, six flight units and at least four pre-flight models and spares, will be even more time consuming and expensive. We question the need for ultra-low expansion glass for the optical bench. We will streamline the design of the bench and explore other materials and assembly techniques to significantly simplify the manufacturing process. Why are we confident that this is possible? One argument is that in early LISA designs the reference cavity was also part of the bench. This cavity drove the requirements to 30 fm/#Hz, a factor 30 more stringent compared to the current requirements. Since the cavity has now been removed from the bench, the requirements have been relaxed. A second argument is that we demonstrated pm/#Hz performance for a number of different materials and structures which are all candidate materials for the telescopes which also have to meet the same requirements over actually a larger distance. Our objective is to take a fresh look at the optical bench. We will redesign core parts of the interferometer bench with a focus on reducing the number and lengths of critical paths and moving non-critical parts away from the core part of the bench and sometimes even into optical fibers. We also propose to use different materials and assembly techniques for the optical bench and strongly believe that they will still meet the pm/#Hz requirement and will also be stable on long time scales. This confidence is based on nearly ten years of experience during which we investigated different materials and structures for the telescopes which we plan to apply now to the optical bench.
RPE and Velocity Relationships for the Back Squat, Bench Press, and Deadlift in Powerlifters.
Helms, Eric R; Storey, Adam; Cross, Matt R; Brown, Scott R; Lenetsky, Seth; Ramsay, Hamish; Dillen, Carolina; Zourdos, Michael C
2017-02-01
Helms, ER, Storey, A, Cross, MR, Browm, SR, Lenetsky, S, Ramsay, H, Dillen, C, and Zourdos, MC. RPE and velocity relationships for the back squat, bench press, and deadlift in powerlifters. J Strength Cond Res 31(2): 292-297, 2017-The purpose of this study was to compare average concentric velocity (ACV) and rating of perceived exertion (RPE) based on repetitions in reserve on the squat, bench press, and deadlift. Fifteen powerlifters (3 women and 12 men, mean age 28.4 ± 8.5 years) worked up to a one repetition maximum (1RM) on each lift. Rating of perceived exertion was recorded on all sets, and the ACV was recorded for all sets performed at 80% of estimated 1RM and higher, up to 1RM. Rating of perceived exertion at 1RM on squat, bench press, and deadlift was 9.6 ± 0.5, 9.7 ± 0.4, and 9.6 ± 0.5, respectively and was not significantly different (p > 0.05). The ACV at 1RM on squat, bench press and deadlift was 0.23 ± 0.05, 0.10 ± 0.04, and 0.14 ± 0.05 m·second, respectively. Squat was faster than both bench press and deadlift (p > 0.001), and deadlift was faster than bench press (p = 0.05). Very strong relationships (r = 0.88-0.91) between percentage 1RM and RPE were observed on each lift. The ACV showed strong (r = -0.79 to -0.87) and very strong (r = -0.90 to 92) inverse relationships with RPE and percentage 1RM on each lift, respectively. We conclude that RPE may be a useful tool for prescribing intensity for squat, bench press, and deadlift in powerlifters, in addition to traditional methods such as percentage of 1RM. Despite high correlations between percentage 1RM and ACV, a "velocity load profile" should be developed to prescribe intensity on an individual basis with appropriate accuracy.
Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Matsuda, Chu; Yamamoto, Hirofumi; Mizushima, Tsunekazu; Mori, Masaki; Doki, Yuichiro; Nakajima, Kiyokazu
2018-06-01
Modern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings. SBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries. In the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery. We successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.
Mechanics of Granular Materials (MGM0 Flight Hardware in Bench Test
NASA Technical Reports Server (NTRS)
2000-01-01
Engineering bench system hardware for the Mechanics of Granular Materials (MGM) experiment is tested on a lab bench at the University of Colorado in Boulder. This is done in a horizontal arrangement to reduce pressure differences so the tests more closely resemble behavior in the microgravity of space. Sand and soil grains have faces that can cause friction as they roll and slide against each other, or even cause sticking and form small voids between grains. This complex behavior can cause soil to behave like a liquid under certain conditions such as earthquakes or when powders are handled in industrial processes. MGM experiments aboard the Space Shuttle use the microgravity of space to simulate this behavior under conditions that carnot be achieved in laboratory tests on Earth. MGM is shedding light on the behavior of fine-grain materials under low effective stresses. Applications include earthquake engineering, granular flow technologies (such as powder feed systems for pharmaceuticals and fertilizers), and terrestrial and planetary geology. Nine MGM specimens have flown on two Space Shuttle flights. Another three are scheduled to fly on STS-107. The principal investigator is Stein Sture of the University of Colorado at Boulder. (Credit: University of Colorado at Boulder).
Barnhill, William C.; Gao, Hong; Kheireddin, Bassem; ...
2015-09-29
We have previously reported an oil-miscible phosphonium-organophosphate ionic liquid (IL) with an effective anti-wear (AW) functionality when added to a base oil by itself or combined with a conventional zinc dialkyldithiophosphate (ZDDP) for a synergistic effect. In this research, we investigated whether this synergy manifests in formulated engine oils. An experimental SAE 0W-16 engine oil was generated containing a combination of IL and ZDDP with equal phosphorus contribution. The prototype engine oil was first evaluated using tribological bench tests: AW performance in boundary lubrication (BL) and friction behavior (Stribeck curves) in elastohydrodynamic, mixed, and BL. In addition, the forthcoming standardmore » Sequence VIE engine dynamometer test was then conducted to demonstrate improved fuel economy. Results were benchmarked against those of another experimental engine oil with almost the same formulation except using ZDDP only without the IL (similar total phosphorus content). The IL-ZDDP formulation consistently outperforms the ZDDP-only formulation in friction reduction and wear protection, and results from the bench and engine tests are well correlated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hilary Wheeler; Crystal Densmore
2007-07-31
The diamine reagent 1,2-bis(2-aminophenylthio)ethane is no longer commercially available but still required for the synthesis of the bismaleimide resin, APO-BMI, used in syntactic foams. In this work, we examined the hydrolysis of benzothiazole followed the by reaction with dichloroethane or dibromoethane. We also studied the deprotonation of 2-aminothiophenol followed by the reaction with dibromoethane. We optimized the latter for scale-up by scrutinizing all aspects of the reaction conditions, work-up and recrystallization. On bench-scale, our optimized procedure consistently produced a 75-80% overall yield of finely divided, high purity product (>95%).
Transportable Applications Environment Plus, Version 5.1
NASA Technical Reports Server (NTRS)
1994-01-01
Transportable Applications Environment Plus (TAE+) computer program providing integrated, portable programming environment for developing and running application programs based on interactive windows, text, and graphical objects. Enables both programmers and nonprogrammers to construct own custom application interfaces easily and to move interfaces and application programs to different computers. Used to define corporate user interface, with noticeable improvements in application developer's and end user's learning curves. Main components are; WorkBench, What You See Is What You Get (WYSIWYG) software tool for design and layout of user interface; and WPT (Window Programming Tools) Package, set of callable subroutines controlling user interface of application program. WorkBench and WPT's written in C++, and remaining code written in C.
Fuel-Flexible Gasification-Combustion Technology for Production of H2 and Sequestration-Ready CO2
DOE Office of Scientific and Technical Information (OSTI.GOV)
George Rizeq; Janice West; Raul Subia
GE Global Research is developing an innovative energy technology for coal gasification with high efficiency and near-zero pollution. This Unmixed Fuel Processor (UFP) technology simultaneously converts coal, steam and air into three separate streams of hydrogen-rich gas, sequestration-ready CO{sub 2}, and high-temperature, high-pressure vitiated air to produce electricity in gas turbines. This is the draft final report for the first stage of the DOE-funded Vision 21 program. The UFP technology development program encompassed lab-, bench- and pilot-scale studies to demonstrate the UFP concept. Modeling and economic assessments were also key parts of this program. The chemical and mechanical feasibility weremore » established via lab and bench-scale testing, and a pilot plant was designed, constructed and operated, demonstrating the major UFP features. Experimental and preliminary modeling results showed that 80% H{sub 2} purity could be achieved, and that a UFP-based energy plant is projected to meet DOE efficiency targets. Future work will include additional pilot plant testing to optimize performance and reduce environmental, operability and combined cycle integration risks. Results obtained to date have confirmed that this technology has the potential to economically meet future efficiency and environmental performance goals.« less
Ion projection lithography: November 2000 status and sub-70-nm prospects
NASA Astrophysics Data System (ADS)
Kaesmaier, Rainer; Wolter, Andreas; Loeschner, Hans; Schunck, Stefan
2000-10-01
Among all next generation lithography (NGL) options Ion Projection Lithography (IPL) offers the smallest (particle) wavelength of 5x10- 5nm (l00keV Helium ions). Thus, 4x reduction ion-optics has diffraction limits <3nm even when using a numerical aperture as low as NAequals10-5. As part of the European MEDEA IPL project headed by Infineon Technologies wide field ion-optics have been designed by IMS- Vienna with predicted resolution of 50nm within a 12.5mm exposure field. The ion-optics part of the PDT tool (PDT-IOS) has been realized and assembled. In parallel to the PDT-IOS effort, at Leica Jena a test bench for a vertical vacuum 300mm-wafer stage has been realized. Operation of magnetic bearing supported stage movement has already been demonstrated. As ASML vacuum compatible optical wafer alignment system, with 3nm(3(sigma) ) precision demonstrated in air, has been integrated to this wafer test bench system recently. Parallel to the IPL tool development, Infineon Technologies Mask House and the Institute for Microelectronics Stuttgart are intensively working on the development of IPL stencil masks with success in producing 150mm and 200mm stencil masks as reported elsewhere. This paper is focused on information about the status of the PDT-IOS tool.
Bench to beside: motivation for university industry partnership.
Thakor, Nitish V
2009-01-01
This paper discusses the motivation for entrepreneurship in academia and for forging a relationship between an academic laboratory and a startup. University based personnel, faculty and students, priorities basic bench research. On the other side, industry, particularly startups, prioritize technology development for clinical and commercial translation. The paper presents personal experience as a case study. University based researchers, faculty and students, might participate in and benefit from such an entrepreneurial activity. A University spin off would facilitate translational of bench research ideas and results to technologies for bedside use. Attention to issues such as conflict of interest and concern and ethics of working with human subjects need to be managed by the investigators and the institution. While entrepreneurial activity is not for everyone, it does provide the benefit and satisfaction to see research reach practice.
Assessing sorbent injection mercury control effectiveness in flue gas streams
Carey, T.R.; Richardson, C.F.; Chang, R.; Meserole, F.B.; Rostam-Abadi, M.; Chen, S.
2000-01-01
One promising approach for removing mercury from coal-fired, utility flue gas involves the direct injection of mercury sorbents. Although this method has been effective at removing mercury in municipal waste incinerators, tests conducted to date on utility coal-fired boilers show that mercury removal is much more difficult in utility flue gas. EPRI is conducting research to investigate mercury removal using sorbents in this application. Bench-scale, pilot-scale, and field tests have been conducted to determine the ability of different sorbents to remove mercury in simulated and actual flue gas streams. This paper focuses on recent bench-scale and field test results evaluating the adsorption characteristics of activated carbon and fly ash and the use of these results to develop a predictive mercury removal model. Field tests with activated carbon show that adsorption characteristics measured in the lab agree reasonably well with characteristics measured in the field. However, more laboratory and field data will be needed to identify other gas phase components which may impact performance. This will allow laboratory tests to better simulate field conditions and provide improved estimates of sorbent performance for specific sites. In addition to activated carbon results, bench-scale and modeling results using fly ash are presented which suggest that certain fly ashes are capable of adsorbing mercury.
Design of the ANTARES LCM-DAQ board test bench using a FPGA-based system-on-chip approach
NASA Astrophysics Data System (ADS)
Anvar, S.; Kestener, P.; Le Provost, H.
2006-11-01
The System-on-Chip (SoC) approach consists in using state-of-the-art FPGA devices with embedded RISC processor cores, high-speed differential LVDS links and ready-to-use multi-gigabit transceivers allowing development of compact systems with substantial number of IO channels. Required performances are obtained through a subtle separation of tasks between closely cooperating programmable hardware logic and user-friendly software environment. We report about our experience in using the SoC approach for designing the production test bench of the off-shore readout system for the ANTARES neutrino experiment.
ESA's CCD test bench for the PLATO mission
NASA Astrophysics Data System (ADS)
Beaufort, Thierry; Duvet, Ludovic; Bloemmaert, Sander; Lemmel, Frederic; Prod'homme, Thibaut; Verhoeve, Peter; Smit, Hans; Butler, Bart; van der Luijt, Cornelis; Heijnen, Jerko; Visser, Ivo
2016-08-01
PLATO { PLAnetary Transits and Oscillations of stars { is the third medium-class mission to be selected in the European Space Agency (ESA) Science and Robotic Exploration Cosmic Vision programme. Due for launch in 2025, the payload makes use of a large format (8 cm x 8 cm) Charge-Coupled Devices (CCDs), the e2v CCD270 operated at 4 MHz and at -70 C. To de-risk the PLATO CCD qualification programme initiated in 2014 and support the mission definition process, ESA's Payload Technology Validation section from the Future Missions Office has developed a dedicated test bench.
Characterization benches for neutrino telescope Optical Modules at the APC laboratory
NASA Astrophysics Data System (ADS)
Avgitas, Theodore; Creusot, Alexandre; Kouchner, Antoine
2016-04-01
As has been demonstrated by the first generation of neutrino telescopes Antares and IceCube, precise knowledge of the photon detection efficiency of optical modules is of fundamental importance for the understanding of the instrument and accurate event reconstruction. Dedicated test benches have been developed to measure all related quantities for the Digital Optical Modules of the KM3NeT neutrino telescope being currently deployed in the Mediterranean sea. The first bench is a black box with robotic arms equipped with a calibrated single photon source or laser which enable a precise mapping of the detection efficiency at arbitrary incident angles as well as precise measurements of the time delays induced by the photodetection chain. These measurement can be incorporated and compared to full GEANT MonteCarlo simulations of the optical modules. The second bench is a 2 m×2 m ×2 m water tank equipped with muon hodoscopes on top and bottom. It enables to study and measure the angular dependence of the DOM's detection efficiency of the Cherenkov light produced in water by relativistic muons, thus reproducing in situ detection conditions. We describe these two benches and present their first results and status.
Orange, Samuel T; Metcalfe, James W; Liefeith, Andreas; Marshall, Phil; Madden, Leigh A; Fewster, Connor R; Vince, Rebecca V
2018-05-08
Orange, ST, Metcalfe, JW, Liefeith, A, Marshall, P, Madden, LA, Fewster, CR, and Vince, RV. Validity and reliability of a wearable inertial sensor to measure velocity and power in the back squat and bench press. J Strength Cond Res XX(X): 000-000, 2018-This study examined the validity and reliability of a wearable inertial sensor to measure velocity and power in the free-weight back squat and bench press. Twenty-nine youth rugby league players (18 ± 1 years) completed 2 test-retest sessions for the back squat followed by 2 test-retest sessions for the bench press. Repetitions were performed at 20, 40, 60, 80, and 90% of 1 repetition maximum (1RM) with mean velocity, peak velocity, mean power (MP), and peak power (PP) simultaneously measured using an inertial sensor (PUSH) and a linear position transducer (GymAware PowerTool). The PUSH demonstrated good validity (Pearson's product-moment correlation coefficient [r]) and reliability (intraclass correlation coefficient [ICC]) only for measurements of MP (r = 0.91; ICC = 0.83) and PP (r = 0.90; ICC = 0.80) at 20% of 1RM in the back squat. However, it may be more appropriate for athletes to jump off the ground with this load to optimize power output. Further research should therefore evaluate the usability of inertial sensors in the jump squat exercise. In the bench press, good validity and reliability were evident only for the measurement of MP at 40% of 1RM (r = 0.89; ICC = 0.83). The PUSH was unable to provide a valid and reliable estimate of any other criterion variable in either exercise. Practitioners must be cognizant of the measurement error when using inertial sensor technology to quantify velocity and power during resistance training, particularly with loads other than 20% of 1RM in the back squat and 40% of 1RM in the bench press.
Control of air emissions from POTWs using biofiltration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webster, T.S.; Devinny, J.S.; Torres, E.M.
1995-12-31
The University of Southern California (USC), in collaboration with the County Sanitation Districts of Orange County (CSDOC), the South Coast Air Quality Management District (SCAQMD), Southern California Edison (SCE), the Water Environment Research Foundation (WERF), and Huntingdon Environmental Engineering, Inc. (HEEI), is conducting a research project to evaluate the application of biofiltration to remove volatile organic compounds (VOCs), odor-causing air pollutants, and toxics from a publicly owned treatment works (POTW) waste airstream. As part of this project, bench-scale and pilot-scale experiments are being conducted to test the effectiveness of biofiltration and determine the optimum parameters for applying biofiltration to POTWs.more » Results from the bench-scale experiments demonstrate that biofiltration is effective in reducing the concentration of hydrogen sulfide (H{sub 2}S) and total VOCs present in waste airstreams by over 99% and up to 90%, respectively. Average reduction of specific aromatic and carbonyl compounds ranged from 55% to 91%. Removal efficiencies for chlorinated hydrocarbons were variable, ranging from 6% to 88%. Overall, biofiltration appears to be a promising technology for full-scale implementation at POTWs for VOC and odor emission compliance.« less
Soares, Enrico Gori; Brown, Lee E.; Gomes, Willy Andrade; Corrêa, Daniel Alves; Serpa, Érica Paes; da Silva, Josinaldo Jarbas; Junior, Guanis de Barros Vilela; Fioravanti, Gustavo zorzi; Aoki, Marcelo Saldanha; Lopes, Charles Ricardo; Marchetti, Paulo Henrique
2016-01-01
The purpose of this study was to measure the acute effects of pre-exhaustion vs. traditional exercise order on neuromuscular performance and sEMG in trained men. Fourteen young, healthy, resistance trained men (age: 25.5 ± 4.0 years, height: 174.9 ± 4.1 cm, and total body mass: 80.0 ± 11.1 kg) took part of this study. All tests were randomized and counterbalanced for all subjects and experimental conditions. Volunteers attended one session in the laboratory. First, they performed ten repetition maximum (10RM) tests for each exercise (bench press and triceps pushdown) separately. Secondly, they performed all three conditions at 10RM: pre-test (bench press and triceps pushdown, separately), pre-exhaustion (triceps pushdown+bench press, PE) and traditional (bench press+triceps pushdown, TR), and rested 30 minutes between conditions. Results showed that pre-test was significantly greater than PE (p = 0.031) but not different than TR, for total volume load lifted. There was a significant difference between the pre-test and the time-course of lactate measures (p = 0.07). For bench press muscle activity of the pectoralis major, the last repetition was significantly greater than the first repetition (pre-test: p = 0.006, PE: p = 0.016, and TR: p = 0.005). Also, for muscle activity of the triceps brachii, the last repetition was significantly greater than the first repetition (pre-test: p = 0.001, PE: p = 0.005, and TR: p = 0.006). For triceps pushdown, muscle activity of the triceps brachii, the last repetition was significantly greater than the first repetition (pre-test: p = 0.006, PE: p = 0.016, and TR: p = 0.005). For RPE, there were no significant differences between PE and TR (p = 0.15). Our results suggest that exercise order decreases repetitions performed, however, neuromuscular fatigue, lactate, and RPE are not impacted. The lack of difference in total volume load lifted between PE and TR might explain, at least in part, the similar metabolic and perceptual responses. Key points The effects of different exercise order schemes (e.g. PE and TR) on muscle activity and strength performance indicated that similar responses were observed when comparing these schemes. Strength and conditioning coaches should consider these results when prescribing resistance training programs. The primary target (e.g. muscle group) of the training session should trained first, when fatigue level low, in order to maximize training outcomes. PMID:26957933
NASA Astrophysics Data System (ADS)
Blake, Will; Walsh, Rory; Bidin, Kawi; Annammala, Kogila
2015-04-01
It is widely recognised that commercial logging and conversion of tropical rainforest to oil palm plantation leads to enhanced fluvial sediment flux to the coastal zone but the dynamics of delivery and mechanisms that act to retain sediment and nutrients within rainforest ecosystems, e.g. riparian zone and floodplain storage, are poorly understood and underexploited as a management tool. While accretion of lateral in-channel bench deposits in response to forest clearance has been demonstrated in temperate landscapes, their development and value as sedimentary archives of catchment response to human disturbance remains largely unexplored in tropical rainforest river systems. Working within the Segama River basin, Sabah, Malaysian Borneo, this study aimed to test the hypothesis that (1) lateral bench development in tropical rainforest rivers systems is enhanced by upstream catchment disturbance and that (2) the sedimentary record of these deposits can be used to infer changes in sediment provenance and intensification of sediment flux associated with logging activities. Sediment cores were taken from in-channel bench deposits with upstream catchment contributing areas of 721 km2 and 2800 km2 respectively. Accretion rates were determined using fallout 210Pb and 137Cs and the timing of peak accumulation was shown to correspond exactly with the known temporal pattern of logging and associated fluvial sediment response over the period 1980 to present following low pre-logging rates. Major and minor element geochemistry of deposits was used to assess the degree of weathering that deposited sediment had experienced. This was linked to surface (heavily weathered) and subsurface (less weathered) sediment sources relating to initial disturbance by logging and post-logging landsliding responses respectively. A shift in the dominant source of deposited material from surface (i.e. topsoil) to subsurface (i.e. relatively unweathered subsoil close to bedrock) origin was observed to coincide with the increase in accretion rates following logging of steep headwater slopes. Coherence of sedimentary, monitoring and observational evidence demonstrates that in-channel bench deposits offer a previously unexplored sedimentary archive of catchment response to logging in tropical rainforest systems and a tool for evaluating the erosional responses of ungauged basins. In-channel bench development due to catchment disturbance may augment ecosystem services provided by the riparian corridors of larger rivers and process knowledge gained from sedimentary archives can be used to underpin future riparian and catchment forest management strategies.
Cell module and fuel conditioner development
NASA Astrophysics Data System (ADS)
Hoover, D. Q., Jr.
1980-01-01
Components for the first 5 cell stack (no cooling plates) of the MK-2 design were fabricated. Preliminary specfications and designs for the components of a 23 cell MK-1 stack with four DIGAS cooling plates were developed. The MK-2 was selected as a bench mark design and a preliminary design of the facilities required for high rate manufacture of fuel cell modules was developed. Two stands for testing 5 cell stacks were built and design work for modifying existing stands and building new stands for 23 and 80 cell stacks was initiated. Design and procurement of components and materials for the catalyst test stand were completed and construction initiated. Work on the specifications of pipeline gas, tap water and recovered water and definition of equipment required for treatment was initiated. An innovative geometry for the reformer was conceived and modifications of the computer program to be used in its design were stated.
Finite element fatigue analysis of rectangular clutch spring of automatic slack adjuster
NASA Astrophysics Data System (ADS)
Xu, Chen-jie; Luo, Zai; Hu, Xiao-feng; Jiang, Wen-song
2015-02-01
The failure of rectangular clutch spring of automatic slack adjuster directly affects the work of automatic slack adjuster. We establish the structural mechanics model of automatic slack adjuster rectangular clutch spring based on its working principle and mechanical structure. In addition, we upload such structural mechanics model to ANSYS Workbench FEA system to predict the fatigue life of rectangular clutch spring. FEA results show that the fatigue life of rectangular clutch spring is 2.0403×105 cycle under the effect of braking loads. In the meantime, fatigue tests of 20 automatic slack adjusters are carried out on the fatigue test bench to verify the conclusion of the structural mechanics model. The experimental results show that the mean fatigue life of rectangular clutch spring is 1.9101×105, which meets the results based on the finite element analysis using ANSYS Workbench FEA system.
NASA Astrophysics Data System (ADS)
Lin, Wei-Cheng; Chang, Shenq-Tsong; Yu, Zong-Ru; Lin, Yu-Chuan; Ho, Cheng-Fong; Huang, Ting-Ming; Chen, Cheng-Huan
2014-09-01
A Cassegrain telescope with a 450 mm clear aperture was developed for use in a spaceborne optical remote-sensing instrument. Self-weight deformation and thermal distortion were considered: to this end, Zerodur was used to manufacture the primary mirror. The lightweight scheme adopted a hexagonal cell structure yielding a lightweight ratio of 50%. In general, optical testing on a lightweight mirror is a critical technique during both the manufacturing and assembly processes. To prevent unexpected measurement errors that cause erroneous judgment, this paper proposes a novel and reliable analytical method for optical testing, called the bench test. The proposed algorithm was used to distinguish the manufacturing form error from surface deformation caused by the mounting, supporter and gravity effects for the optical testing. The performance of the proposed bench test was compared with a conventional vertical setup for optical testing during the manufacturing process of the lightweight mirror.
NASA Technical Reports Server (NTRS)
Marshburn, J. P.
1973-01-01
Techniques associated with thermal-vacuum and bench testing, along with flight testing of the OAO-C spacecraft heat pipes are outlined, to show that the processes used in heat transfer design and testing are adequate for good performance evaluations.
Validation and Reliability of a Novel Test of Upper Body Isometric Strength.
Bellar, David; Marcus, Lena; Judge, Lawrence W
2015-09-29
The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a "push-up" style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (p<0.05). Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.
Validation and Reliability of a Novel Test of Upper Body Isometric Strength
Bellar, David; Marcus, Lena; Judge, Lawrence W.
2015-01-01
The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (p<0.05). Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment. PMID:26557203
Advanced direct coal liquefaction concepts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, D.J.; Parker, R.J.; Simpson, P.L.
During the first quarter of FY 1993, the Project proceeded close to the Project Plan. The analysis of the feed material has been completed as far as possible. Some unplanned distillation was needed to correct the boiling range of the Black Thunder solvent used during the autoclave tests. Additional distillation will be required if the same solvent is to be used for the bench unit tests. A decision on this is still outstanding. The solvent to be used with Illinois No. 6 coal has not yet been defined. As a result, the procurement of the feed and the feed analysismore » is somewhat behind schedule. Agglomeration tests with Black Thunder coal indicates that small agglomerates can be formed. However, the ash removal is quite low (about 10%), which is not surprising in view of the low ash content of the coal. The first series of autoclave tests with Black Thunder coal was completed as planned. Also, additional runs are in progress as repeats of previous runs or at different operating conditions based on the data obtained so far. The results are promising indicating that almost complete solubilization (close to 90%) of Black Thunder coal can be achieved in a CO/H[sub 2]O environment at our anticipated process conditions. The design of the bench unit has been completed. In contrast to the originally planned modifications, the bench unit is now designed based on a computerized control and data acquisition system. All major items of equipment have been received, and prefabrication of assemblies and control panels is proceeding on schedule. Despite a slight delay in the erection of the structural steel, it is anticipated that the bench unit will be operational at the beginning of April 1993.« less
Advanced direct coal liquefaction concepts. Quarterly report, October 1, 1992--December 31, 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, D.J.; Parker, R.J.; Simpson, P.L.
During the first quarter of FY 1993, the Project proceeded close to the Project Plan. The analysis of the feed material has been completed as far as possible. Some unplanned distillation was needed to correct the boiling range of the Black Thunder solvent used during the autoclave tests. Additional distillation will be required if the same solvent is to be used for the bench unit tests. A decision on this is still outstanding. The solvent to be used with Illinois No. 6 coal has not yet been defined. As a result, the procurement of the feed and the feed analysismore » is somewhat behind schedule. Agglomeration tests with Black Thunder coal indicates that small agglomerates can be formed. However, the ash removal is quite low (about 10%), which is not surprising in view of the low ash content of the coal. The first series of autoclave tests with Black Thunder coal was completed as planned. Also, additional runs are in progress as repeats of previous runs or at different operating conditions based on the data obtained so far. The results are promising indicating that almost complete solubilization (close to 90%) of Black Thunder coal can be achieved in a CO/H{sub 2}O environment at our anticipated process conditions. The design of the bench unit has been completed. In contrast to the originally planned modifications, the bench unit is now designed based on a computerized control and data acquisition system. All major items of equipment have been received, and prefabrication of assemblies and control panels is proceeding on schedule. Despite a slight delay in the erection of the structural steel, it is anticipated that the bench unit will be operational at the beginning of April 1993.« less
Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.
Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R
2017-05-01
Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.
Bench-Scale Filtration Testing in Support of the Pretreatment Engineering Platform (PEP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Billing, Justin M.; Daniel, Richard C.; Kurath, Dean E.
Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP testing program specifies that bench-scale testing is to bemore » performed in support of specific operations, including filtration, caustic leaching, and oxidative leaching.« less
Integration of a UV curable polymer lens and MUMPs structures on a SOI optical bench
NASA Astrophysics Data System (ADS)
Hsieh, Jerwei; Hsiao, Sheng-Yi; Lai, Chun-Feng; Fang, Weileun
2007-08-01
This work presents the design concept of integrating a polymer lens, poly-Si MUMPs and single-crystal-silicon HARM structures on a SOI wafer to form a silicon optical bench. This approach enables the monolithic integration of various optical components on the wafer so as to improve the design flexibility of the silicon optical bench. Fabrication processes, including surface and bulk micromachining on the SOI wafer, have been established to realize bi-convex spherical polymer lenses with in-plane as well as out-of-plane optical axes. In addition, a micro device consisting of an in-plane polymer lens, a thick fiber holder and a mechanical shutter driven by an electrothermal actuator is also demonstrated using the present approach. In summary, this study significantly improves the design flexibility as well as the functions of SiOBs.
Electromyographic activity and 6RM strength in bench press on stable and unstable surfaces.
Saeterbakken, Atle H; Fimland, Marius S
2013-04-01
The purpose of the study was to compare 6-repetition maximum (6RM) loads and muscle activity in bench press on 3 surfaces, namely, stable bench, balance cushion, and Swiss ball. Sixteen healthy, resistance-trained men (age 22.5 ± 2.0 years, stature 1.82 ± 6.6 m, and body mass 82.0 ± 7.8 kg) volunteered for 3 habituation/strength testing sessions and 1 experimental session. In randomized order on the 3 surfaces, 6RM strength and electromyographic activity of pectoralis major, deltoid anterior, biceps brachii, triceps brachii, rectus abdominis, oblique external and erector spinae were assessed. Relative to stable bench, the 6RM strength was approximately 93% for balance cushion (p ≤ 0.001) and approximately 92% for Swiss ball (p = 0.008); the pectoralis major electromyographic (EMG) activity was approximately 90% using the balance cushion (p = 0.080) and approximately 81% using Swiss ball (p = 0.006); the triceps EMG was approximately 79% using the balance cushion (p = 0.028) and approximately 69% using the Swiss ball (p = 0.002). Relative to balance cushion, the EMG activity in pectoralis, triceps, and erector spinae using Swiss ball was approximately 89% (p = 0.016), approximately 88% (p = 0.014) and approximately 80% (p = 0.020), respectively. In rectus abdominis, the EMG activity relative to Swiss ball was approximately 69% using stable bench (p = 0.042) and approximately 65% using the balance cushion (p = 0.046). Similar EMG activities between stable and unstable surfaces were observed for deltoid anterior, biceps brachii, and oblique external. In conclusion, stable bench press had greater 6RM strength and triceps and pectoralis EMG activity compared with the unstable surfaces. These findings have implications for athletic training and rehabilitation, because they demonstrate an inferior effect of unstable surfaces on muscle activation of prime movers and strength in bench press. If an unstable surface in bench press is desirable, a balance cushion should be chosen instead of a Swiss ball.
2018-02-09
A Zero Launch Mass 3-D printer is being tested at the Swamp Works at NASA's Kennedy Space Center in Florida. The printer can be used for construction projects on the Moon and Mars, and even for troops in remote locations on Earth. Zero launch mass refers to the fact that the printer uses pellets made from simulated lunar regolith, or dirt, and polymers to prove that space explorers can use resources at their destination instead of taking everything with them, saving them launch mass and money. The group is working with Marshall Space Flight Center in Huntsville, Alabama, and the U.S. Army Corps of Engineers to develop a system that can 3-D print barracks in remote locations on Earth, using the resources they have where they are.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynch, Kevin; Popp, James
This DOE grant award for was for the period June 1, 2013 to March 31, 2016. Popp was awarded an internship in the Visiting Faculty Program at FNAL in summer of 2015; consequently the unused portion of summer salary funds allowed us to apply for a no-cost extension with our remaining funds until March 31, 2017. That support furnished us with the means to carry out numerous successful projects for Mu2e for nearly four years. Up to now, the driving force to our work has been dictated primarily by the Mu2e Project cost and schedule needs. Our work has beenmore » under the purview of three of the Working Groups to which we belong: Target Station, Electron Tracker, and Stopping Target Monitor. We have carried out a mix of bench-top testing tasks locally, more elaborate work at Fermilab every summer, and extensive software development and simulation studies.« less
Izquierdo, M; González-Badillo, J J; Häkkinen, K; Ibáñez, J; Kraemer, W J; Altadill, A; Eslava, J; Gorostiaga, E M
2006-09-01
The purpose of this study was to examine the effect of different loads on repetition speed during single sets of repetitions to failure in bench press and parallel squat. Thirty-six physical active men performed 1-repetition maximum in a bench press (1 RM (BP)) and half squat position (1 RM (HS)), and performed maximal power-output continuous repetition sets randomly every 10 days until failure with a submaximal load (60 %, 65 %, 70 %, and 75 % of 1RM, respectively) during bench press and parallel squat. Average velocity of each repetition was recorded by linking a rotary encoder to the end part of the bar. The values of 1 RM (BP) and 1 RM (HS) were 91 +/- 17 and 200 +/- 20 kg, respectively. The number of repetitions performed for a given percentage of 1RM was significantly higher (p < 0.001) in half squat than in bench press performance. Average repetition velocity decreased at a greater rate in bench press than in parallel squat. The significant reductions observed in the average repetition velocity (expressed as a percentage of the average velocity achieved during the initial repetition) were observed at higher percentage of the total number of repetitions performed in parallel squat (48 - 69 %) than in bench press (34 - 40 %) actions. The major finding in this study was that, for a given muscle action (bench press or parallel squat), the pattern of reduction in the relative average velocity achieved during each repetition and the relative number of repetitions performed was the same for all percentages of 1RM tested. However, relative average velocity decreased at a greater rate in bench press than in parallel squat performance. This would indicate that in bench press the significant reductions observed in the average repetition velocity occurred when the number of repetitions was over one third (34 %) of the total number of repetitions performed, whereas in parallel squat it was nearly one half (48 %). Conceptually, this would indicate that for a given exercise (bench press or squat) and percentage of maximal dynamic strength (1RM), the pattern of velocity decrease can be predicted over a set of repetitions, so that a minimum repetition threshold to ensure maximal speed performance is determined.
Onder, Ursula; Blauth, Michael; Kralinger, Franz; Schmoelz, Werner
2012-05-30
In our society the average age is increasing, as are the number of proximal humeral head fractures. For fixation of these fractures, an increasing number of implants are available. New fixation devices should be compared biomechanically with established methods in a standardized fashion. The test bench that was designed was intended to simulate abduction motion of the humerus actively induced by muscle forces. We used three pneumatic muscles to apply forces to the tendons of the musculus supraspinatus and the bifid musculus deltoideus. Thus, it was possible to create an active abduction in the scapular plane. Two different fracture models (with and without medial support) were stabilised with an angular stable plate in sawbone models to reproduce a known clinical outcome with the newly designed test setup. The resultant force acting on the proximal humerus reached approximately 47% BW (per cent body weight), which amounted to 329.0 N (SD: 21.76). The supraspinatus reached maximum forces of 254.7 N (SD: 20.1) and the deltoid muscle 258.9 N (SD: 16.5). Fracture gap instrumentation with medial support resulted in a significantly reduced per-cycle fracture gap motion. The performance evaluation showed that the simulator produced predicable, reproducible movements with physiological muscle force magnitudes.
Kouzani, Abbas Z; Kale, Rajas P; Zarate-Garza, Pablo Patricio; Berk, Michael; Walder, Ken; Tye, Susannah J
2017-09-01
Deep brain stimulation (DBS) devices deliver electrical pulses to neural tissue through an electrode. To study the mechanisms and therapeutic benefits of deep brain stimulation, murine preclinical research is necessary. However, conducting naturalistic long-term, uninterrupted animal behavioral experiments can be difficult with bench-top systems. The reduction of size, weight, power consumption, and cost of DBS devices can assist the progress of this research in animal studies. A low power, low weight, miniature DBS device is presented in this paper. This device consists of electronic hardware and software components including a low-power microcontroller, an adjustable current source, an n-channel metal-oxide-semiconductor field-effect transistor, a coin-cell battery, electrode wires and a software program to operate the device. Evaluation of the performance of the device in terms of battery lifetime and device functionality through bench and in vivo tests was conducted. The bench test revealed that this device can deliver continuous stimulation current pulses of strength [Formula: see text], width [Formula: see text], and frequency 130 Hz for over 22 days. The in vivo tests demonstrated that chronic stimulation of the nucleus accumbens (NAc) with this device significantly increased psychomotor activity, together with a dramatic reduction in anxiety-like behavior in the elevated zero-maze test.
Project of electro-cyclotron resonance ion source test-bench for material investigation.
Kulevoy, T V; Chalykh, B B; Kuibeda, R P; Kropachev, G N; Ziiatdinova, A V
2014-02-01
Development of new materials for future energy facilities with higher operating efficiency is a challenging and crucial task. However, full-scale testing of radiation hardness for reactor materials is quite sophisticated and difficult as it requires long session of reactor irradiation; moreover, induced radioactivity considerably complicates further investigation. Ion beam irradiation does not have such a drawback; on the contrary, it has certain advantages. One of them is high speed of defect formation. Therefore, it provides a useful tool for modeling of different radiation damages. Improved understanding of material behavior under high dose irradiation will probably allow to simulate reactor irradiation close to real conditions and to make an adequate estimation of material radiation hardness. Since 2008 in Institute for Theoretical and Experimental Physics, the ion beam irradiation experiments are under development at the heavy ion radio frequency quadrupole linac and very important results are obtained already [T. V. Kulevoy et al., in Proceedings of the International Topical Meeting on Nuclear Research Applications and Utilization of Accelerators, IAEA Vienna, Austria, 2009, http://www.pub.iaea.org/MTCD/publications/PDF/P1433_CD/darasets/papers/ap_p5_07.pdf]. Nevertheless, the new test bench based on electro-cyclotron resonance ion source and high voltage platform is developed. The project of the test bench is presented and discussed.
Project of electro-cyclotron resonance ion source test-bench for material investigation
NASA Astrophysics Data System (ADS)
Kulevoy, T. V.; Chalykh, B. B.; Kuibeda, R. P.; Kropachev, G. N.; Ziiatdinova, A. V.
2014-02-01
Development of new materials for future energy facilities with higher operating efficiency is a challenging and crucial task. However, full-scale testing of radiation hardness for reactor materials is quite sophisticated and difficult as it requires long session of reactor irradiation; moreover, induced radioactivity considerably complicates further investigation. Ion beam irradiation does not have such a drawback; on the contrary, it has certain advantages. One of them is high speed of defect formation. Therefore, it provides a useful tool for modeling of different radiation damages. Improved understanding of material behavior under high dose irradiation will probably allow to simulate reactor irradiation close to real conditions and to make an adequate estimation of material radiation hardness. Since 2008 in Institute for Theoretical and Experimental Physics, the ion beam irradiation experiments are under development at the heavy ion radio frequency quadrupole linac and very important results are obtained already [T. V. Kulevoy et al., in Proceedings of the International Topical Meeting on Nuclear Research Applications and Utilization of Accelerators, IAEA Vienna, Austria, 2009, http://www.pub.iaea.org/MTCD/publications/PDF/P1433_CD/darasets/papers/ap_p5_07.pdf]. Nevertheless, the new test bench based on electro-cyclotron resonance ion source and high voltage platform is developed. The project of the test bench is presented and discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poirier, M.; Burket, P.
The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). Recently, the low filter flux through the ARP of approximately 5 gallons per minute has limited the rate at which radioactive liquid waste can be treated. Salt Batch 6 had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. SRR requested SRNL to conduct bench-scale filter tests to evaluate whether sodium oxalate, sodiummore » aluminosilicate, or aluminum solids (i.e., gibbsite and boehmite) could be the cause of excessive fouling of the crossflow or secondary filter at ARP. The authors conducted the tests by preparing slurries containing 6.6 M sodium Salt Batch 6 supernate, 2.5 g MST/L slurry, and varying concentrations of sodium oxalate, sodium aluminosilicate, and aluminum solids, processing the slurry through a bench-scale filter unit that contains a crossflow primary filter and a dead-end secondary filter, and measuring filter flux and transmembrane pressure as a function of time. Among the conclusions drwn from this work are the following: (1) All of the tests showed some evidence of fouling the secondary filter. This fouling could be from fine particles passing through the crossflow filter. (2) The sodium oxalate-containing feeds behaved differently from the sodium aluminosilicate- and gibbsite/boehmite-containing feeds.« less
Paoli, Antonio; Gentil, Paulo; Moro, Tatiana; Marcolin, Giuseppe; Bianco, Antonino
2017-01-01
The present study aimed to compare the effects of equal-volume resistance training performed with single-joint (SJ) or multi-joint exercises (MJ) on VO 2 max, muscle strength and body composition in physically active males. Thirty-six participants were divided in two groups: SJ group ( n = 18, 182.1 ± 5.2, 80.03 ± 2.78 kg, 23.5 ± 2.7 years) exercised with only SJ exercises (e.g., dumbbell fly, knee extension, etc.) and MJ group ( n = 18, 185.3 ± 3.6 cm, 80.69 ± 2.98 kg, 25.5 ± 3.8 years) with only MJ exercises (e.g., bench press, squat, etc.). The total work volume (repetitions × sets × load) was equated between groups. Training was performed three times a week for 8 weeks. Before and after the training period, participants were tested for VO 2 max, body composition, 1 RM on the bench press, knee extension and squat. Analysis of covariance (ANCOVA) was used to compare post training values between groups, using baseline values as covariates. According to the results, both groups decreased body fat and increased fat free mass with no difference between them. Whilst both groups significantly increased cardiorespiratory fitness and maximal strength, the improvements in MJ group were higher than for SJ in VO 2 max (5.1 and 12.5% for SJ and MJ), bench press 1 RM (8.1 and 10.9% for SJ and MJ), knee extension 1 RM (12.4 and 18.9% for SJ and MJ) and squat 1 RM (8.3 and 13.8% for SJ and MJ). In conclusion, when total work volume was equated, RT programs involving MJ exercises appear to be more efficient for improving muscle strength and maximal oxygen consumption than programs involving SJ exercises, but no differences were found for body composition.
Development of a pyramidal wavefront sensor test-bench at INO
NASA Astrophysics Data System (ADS)
Turbide, Simon; Wang, Min; Gauvin, Jonny; Martin, Olivier; Savard, Maxime; Bourqui, Pascal; Veran, Jean-Pierre; Deschenes, William; Anctil, Genevieve; Chateauneuf, François
2013-12-01
The key technical element of the adaptive optics in astronomy is the wavefront sensing (WFS). One of the advantages of the pyramid wavefront sensor (P-WFS) over the widely used Shack-Hartmann wavefront sensor seems to be the increased sensitivity in closed-loop applications. A high-sensitivity and large dynamic-range WFS, such as P-WFS technology, still needs to be further investigated for proper justification in future Extremely Large Telescopes application. At INO, we have recently carried out the optical design, testing and performance evaluation of a P-WFS bench setup. The optical design of the bench setup mainly consists of the super-LED fiber source, source collimator, spatial light modulator (SLM), relay lenses, tip-tilt mirror, Fourier-transforming lens, and a four-faceted glass pyramid with a large vertex angle as well as pupil re-imaged optics. The phase-only SLM has been introduced in the bench setup to generate atmospheric turbulence with a maximum phase shift of more than 2π at each pixel (256 grey levels). Like a modified Foucault knife-edge test, the refractive pyramid element is used to produce four images of the entrance pupil on a CCD camera. The Fourier-transforming lens, which is used before the pyramid prism, is designed for telecentric output to allow dynamic modulation (rotation of the beam around the pyramid-prism center) from a tip-tilt mirror. Furthermore, a P-WFS diffraction-based model has been developed. This model includes most of the system limitations such as the SLM discrete voltage steps and the CCD pixel pitch. The pyramid effects (edges and tip) are considered as well. The modal wavefront reconstruction algorithm relies on the construction of an interaction matrix (one for each modulation's amplitude). Each column of the interaction matrix represents the combination of the four pupil images for a given wavefront aberration. The nice agreement between the data and the model suggest that the limitation of the system is not the P-WFS itself, but rather its environment such as source intensity fluctuation and vibration of the optical bench. Finally, the phase-reconstruction errors of the P-WFS have been compared to those of a Shack-Hartmann, showing the regions of interest of the former system. The bench setup will be focusing on the astronomy application as well as commercial applications, such as bio-medical application etc.
Influence of ballistic bench press on upper body power output in professional rugby players.
West, Daniel J; Cunningham, Daniel J; Crewther, Blair T; Cook, Christian J; Kilduff, Liam P
2013-08-01
The use of heavy resistance exercise provides an effective preload stimulus for inducing postactivation potentiation (PAP) and increasing peak power output (PPO). However, this approach has limited application in many sporting situations (e.g., incorporation in a precompetition warm-up); and therefore, more practical strategies for inducing PAP need to be investigated. The aim of the present study was to compare the PPO changes after performing a preload stimulus of either a ballistic exercise or a traditional heavy resistance exercise. Twenty professional rugby union players completed 3 testing sessions, each separated by 48 hours. On the first occasion, subjects underwent a 3 repetition maximum (3RM)-bench press testing session. On the next 2 occasions, subjects performed a ballistic bench throw at baseline (30% of 1RM), followed by a preload stimulus of either heavy resistance training (HRT) (heavy bench press: 3 sets of 3 repetitions at 87% 1RM) or BBP (3 sets of 3 repetitions at 30% on 1RM) followed by ballistic bench throw after 8 minutes recovery. The trials were randomized and counterbalanced. Both preload stimuli protocols increased PPO compared with baseline (BBP baseline 892 ± 108 vs. 8 minutes 924 ± 119 W, p < 0.001; HRT baseline 893 ± 104 vs. 8 minutes 931 ± 116 W; p < 0.001). There were no conditional differences between PPO at 8 minutes (p = 0.141); moreover, the change in PPO from baseline was also similar between conditions (BBP Δ + 33 ± 18; HRT Δ + 38 ± 21 W; p = 0.112). In conclusion, a ballistic exercise provided an effective method of inducing PAP and increasing upper-body PPO; moreover, this elicited similar increases in PPO as a traditional heavy resistance exercise preloading stimulus.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-1 General..., such as desks, file and storage cabinets, waste paper baskets, work benches, chair frames, etc. Working...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-1 General..., such as desks, file and storage cabinets, waste paper baskets, work benches, chair frames, etc. Working...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory § 194.15-1 General..., such as desks, file and storage cabinets, waste paper baskets, work benches, chair frames, etc. Working...
Method, apparatus and system for managing queue operations of a test bench environment
Ostler, Farrell Lynn
2016-07-19
Techniques and mechanisms for performing dequeue operations for agents of a test bench environment. In an embodiment, a first group of agents are each allocated a respective ripe reservation and a second set of agents are each allocated a respective unripe reservation. Over time, queue management logic allocates respective reservations to agents and variously changes one or more such reservations from unripe to ripe. In another embodiment, an order of servicing agents allocated unripe reservations is based on relative priorities of the unripe reservations with respect to one another. An order of servicing agents allocated ripe reservations is on a first come, first served basis.
CO 2 Binding Organic Liquids Gas Capture with Polarity Swing Assisted Regeneration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heldebrant, David
This report outlines the comprehensive bench-scale testing of the CO 2-binding organic liquids (CO 2BOLs) solvent platform and its unique Polarity Swing Assisted Regeneration (PSAR). This study outlines all efforts on a candidate CO 2BOL solvent molecule, including solvent synthesis, material characterization, preliminary toxicology studies, and measurement of all physical, thermodynamic and kinetic data, including bench-scale testing. Equilibrium and kinetic models and analysis were made using Aspen Plus™. Preliminary process configurations, a technoeconomic assessment and solvent performance projections for separating CO 2 from a subcritical coal-fired power plant are compared to the U.S. Department of Energy's Case 10 monoethanolamine baseline.
Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.
TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae
2016-01-01
This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.
Taylor, Nigel A S; Lewis, Michael C; Notley, Sean R; Peoples, Gregory E
2012-08-01
Load carriage increases physiological strain, reduces work capacity and elevates the risk of work-related injury. In this project, the separate and combined physiological consequences of wearing the personal protective equipment used by firefighters were evaluated. The overall impact upon performance was first measured in 20 subjects during a maximal, job-related obstacle course trial and an incremental treadmill test to exhaustion (with and without protective equipment). The fractional contributions of the thermal protective clothing, helmet, breathing apparatus and boots were then separately determined during steady-state walking (4.8 km h(-1), 0% gradient) and bench stepping (20 cm at 40 steps min(-1)). The protective equipment reduced exercise tolerance by 56% on a treadmill, with the ambulatory oxygen consumption reserve (peak minus steady-state walking) being 31% lower. For the obstacle course, performance declined by 27%. Under steady-state conditions, the footwear exerted the greatest relative metabolic impact during walking and bench stepping, being 8.7 and 6.4 times greater per unit mass than the breathing apparatus. Indeed, the relative influence of the clothing on oxygen cost was at least three times that of the breathing apparatus. Therefore, the most efficient way to reduce the physiological burden of firefighters' protective equipment, and thereby increase safety, would be to reduce the mass of the boots and thermal protective clothing.
Hosseini, Seiyed Mossa; Tosco, Tiziana
2015-08-01
The work explores the efficacy of a biochemical remediation of a nitrate-contaminated aquifer by a combination of nanoscale zero-valent iron (NZVI) and bacteria supported by carbon substrates. Nitrate removal was first assessed in batch tests, and then in a laboratory bench-scale aquifer model (60cm length×40cm width×50cm height), in which a background flow was maintained. Water and natural sandy material of a stratified aquifer were used in the tests to enhance the reliability of the results. An array of non-pumping-reactive wells (NPRWs) filled with NZVI (d50=50nm, and SSA=22.5m(2)/g) mixed with carbon substrates (beech sawdust and maize cobs) was installed in the bench-scale aquifer model to intercept the flow and remove nitrate (NO3(-) conc.=105mg/l). The NPRW array was preferred to a continuous permeable reactive barrier (PRB) since wells can be drilled at greater depths compared to PRBs. The optimal well diameter, spacing among the NPRWs and number of wells in the bench-scale model were designed based on flow simulations using the semi-analytical particle tracking (advection) model, PMPATH. An optimal configuration of four wells, 35mm diameter, and capture width of 1.8 times the well diameter was obtained for a hydraulic conductivity contrast between reactive materials in the wells and aquifer media (KPM/Kaq=16.5). To avoid excessive proximity between wells, the system was designed so that the capture of the contaminated water was not complete, and several sequential arrays of wells were preferred. To simulate the performance of the array, the water that passed through the bench-scale NPRW system was re-circulated to the aquifer inlet, and a nitrate degradation below the limit target concentration (10mg/l) was obtained after 13days (corresponding to 13 arrays of wells in the field). The results of this study demonstrated that using the NZVI-mixed-carbon substrates in the NPRW system has a great potential for in-situ nitrate reduction in contaminated groundwater. This NPRW system can be considered a promising and viable technology in deep aquifers. Copyright © 2015 Elsevier B.V. All rights reserved.
1997-10-01
This report discusses the results of a bench scale study conducted to evaluate the potential inhibitory effects of untreated AFFF wastewater to the...untreated AFFF wastewater to the nitrification process of the Virginia Initiative Plant biological nutrient removal system. Under this testing, bench...scale reactors simulating the nitrification process were loaded at various AFFF concentrations and the influence on the process performance was
Brennecke, Allan; Guimarães, Thiago M; Leone, Ricardo; Cadarci, Mauro; Mochizuki, Luiz; Simão, Roberto; Amadio, Alberto Carlos; Serrão, Júlio C
2009-10-01
The purpose of the present study was to investigate the effects of exercise order on the tonic and phasic characteristics of upper-body muscle activity during bench press exercise in trained subjects. The preexhaustion method involves working a muscle or a muscle group combining a single-joint exercise immediately followed by a multi-joint exercise (e.g., flying exercise followed by bench press exercise). Twelve subjects performed 1 set of bench press exercises with and without the preexhaustion method following 2 protocols (P1-flying before bench press; P2-bench press). Both exercises were performed at a load of 10 repetition maximum (10RM). Electromyography (EMG) sampled at 1 kHz was recorded from the pectoralis major (PM), anterior deltoid (DA), and triceps brachii (TB). Kinematic data (60 Hz) were synchronized to define upward and downward phases of exercise. No significant (p > 0.05) changes were seen in tonic control of PM and DA muscles between P1 and P2. However, TB tonic aspect of neurophysiologic behavior of motor units was significantly higher (p < 0.05) during P1. Moreover, phasic control of PM, DA, and TB muscles were not affected (p > 0.05). The kinematic pattern of movement changed as a result of muscular weakness in P1. Angular velocity of the right shoulder performed during the upward phase of the bench press exercise was significantly slower (p < 0.05) during P1. Our results suggest that the strategies set by the central nervous system to provide the performance required by the exercise are held constant throughout the exercise, but the tonic aspects of the central drive are increased so as to adapt to the progressive occurrence of the neuromuscular fatigue. Changes in tonic control as a result of the muscular weakness and fatigue can cause changes in movement techniques. These changes may be related to limited ability to control mechanical loads and mechanical energy transmission to joints and passive structures.
Variability-aware compact modeling and statistical circuit validation on SRAM test array
NASA Astrophysics Data System (ADS)
Qiao, Ying; Spanos, Costas J.
2016-03-01
Variability modeling at the compact transistor model level can enable statistically optimized designs in view of limitations imposed by the fabrication technology. In this work we propose a variability-aware compact model characterization methodology based on stepwise parameter selection. Transistor I-V measurements are obtained from bit transistor accessible SRAM test array fabricated using a collaborating foundry's 28nm FDSOI technology. Our in-house customized Monte Carlo simulation bench can incorporate these statistical compact models; and simulation results on SRAM writability performance are very close to measurements in distribution estimation. Our proposed statistical compact model parameter extraction methodology also has the potential of predicting non-Gaussian behavior in statistical circuit performances through mixtures of Gaussian distributions.
Design of a Test Bench for Intraocular Lens Optical Characterization
NASA Astrophysics Data System (ADS)
Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.
2011-01-01
The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its analysis through expansion in Zernike polynomials.
Coal-oil coprocessing at HTI - development and improvement of the technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stalzer, R.H.; Lee, L.K.; Hu, J.
1995-12-31
Co-Processing refers to the combined processing of coal and petroleum-derived heavy oil feedstocks. The coal feedstocks used are those typically utilized in direct coal liquefaction: bituminous, subbituminous, and lignites. Petroleum-derived oil, is typically a petroleum residuum, containing at least 70 W% material boiling above 525{degrees}C. The combined coal and oil feedstocks are processed simultaneously with the dual objective of liquefying the coal and upgrading the petroleum-derived residuum to lower boiling (<525{degrees}C) premium products. HTI`s investigation of the Co-Processing technology has included work performed in laboratory, bench and PDU scale operations. The concept of co-processing technology is quite simple and amore » natural outgrowth of the work done with direct coal liquefaction. A 36 month program to evaluate new process concepts in coal-oil coprocessing at the bench-scale was begun in September 1994 and runs until September 1997. Included in this continuous bench-scale program are provisions to examine new improvements in areas such as: interstage product separation, feedstock concentrations (coal/oil), improved supported/dispersed catalysts, optimization of reactor temperature sequencing, and in-line hydrotreating. This does not preclude other ideas from DOE contracts and other sources that can lead to improved product quality and economics. This research work has led to important findings which significantly increased liquid yields, improved product quality, and improved process economics.« less
Manufacturing, integration, and test results of the MATISSE cold optics bench
NASA Astrophysics Data System (ADS)
Bettonvil, Felix C. M.; Kroes, G.; Agoćs, T.; van Duin, A.; Elswijk, E.; de Haan, M.; ter Horst, R.; Kragt, J.; Kuindersma, J.; Navarro, R.; Roelfsema, R.; Schuil, M.; Tromp, T.; Venema, L.; van Kessel, F.; Jaskó, A.
2014-07-01
MATISSE is the second-generation mid-infrared interferometric spectrograph and imager for ESO's Very Large Telescope Interferometer (VLTI). NOVA-ASTRON is responsible for the Cold Optics Bench (COB), representing the last part of the optics train where the four beams are re-arranged, spectrally dispersed and combined. The COB consist of two sister units, one for the LM-band, one for the N-band, which were successively completed at NOVA-ASTRON in autumn 2013 and spring 2014. The LM-band COB is under cryogenic test in its cryostat at MPIA/Heidelberg; the N-band COB finished cryogenic tests and has been installed at OCA/Nice for integration together with the Warm Optics. This paper focuses on the manufacturing, integration and test results of the COBs, and gives an overview of the current status.
Design and development of a 40 kV pierce electron gun
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhattacharjee, D.; Tiwari, R.; Jayaprakash, D., E-mail: dhruva.bhattacharjee@gmail.com
A 40 kV electron gun is designed and developed using the Pierce configuration for the focusing electrode. Simulations were carried out using CST Particle Studio. The Gun is a thermionic type electron gun with indirect heating of the LaB6 cathode. The gun is capable of delivering a beam current of more than 500 mA at 40 kV with a beam size of less than 5 mm. The cathode assembly consists of cups and heat shields made out of Tantalum and Rhenium sheets. The cathode assembly and the electron gun was fabricated, assembled and tested on test bench for cathode conditioning,more » HV conditioning and beam characterization. This paper presents the gun design, particle simulations study, testing of the gun on test bench. (author)« less
Comparison of the goals and MISTELS scores for the evaluation of surgeons on training benches.
Wolf, Rémi; Medici, Maud; Fiard, Gaëlle; Long, Jean-Alexandre; Moreau-Gaudry, Alexandre; Cinquin, Philippe; Voros, Sandrine
2018-01-01
Evaluation of surgical technical abilities is a major issue in minimally invasive surgery. Devices such as training benches offer specific scores to evaluate surgeons but cannot transfer in the operating room (OR). A contrario, several scores measure performance in the OR, but have not been evaluated on training benches. Our aim was to demonstrate that the GOALS score, which can effectively grade in the OR the abilities involved in laparoscopy, can be used for evaluation on a laparoscopic testbench (MISTELS). This could lead to training systems that can identify more precisely the skills that have been acquired or must still be worked on. 32 volunteers (surgeons, residents and medical students) performed the 5 tasks of the MISTELS training bench and were simultaneously video-recorded. Their performance was evaluated with the MISTELS score and with the GOALS score based on the review of the recording by two experienced, blinded laparoscopic surgeons. The concurrent validity of the GOALS score was assessed using Pearson and Spearman correlation coefficients with the MISTELS score. The construct validity of the GOALS score was assessed with k-means clustering and accuracy rates. Lastly, abilities explored by each MISTELS task were identified with multiple linear regression. GOALS and MISTELS scores are strongly correlated (Pearson correlation coefficient = 0.85 and Spearman correlation coefficient = 0.82 for the overall score). The GOALS score proves to be valid for construction for the tasks of the training bench, with a better accuracy rate between groups of level after k-means clustering, when compared to the original MISTELS score (accuracy rates, respectively, 0.75 and 0.56). GOALS score is well suited for the evaluation of the performance of surgeons of different levels during the completion of the tasks of the MISTELS training bench.
Tandogan, Tamer; Auffarth, Gerd U; Choi, Chul Y; Liebing, Stephanie; Mayer, Christian; Khoramnia, Ramin
2017-02-08
To analyse objective optical properties of the spherical and aspheric design of the same intraocular lens (IOL) model using optical bench analysis. This study entailed a comparative analysis of 10 spherical C-flex 570 C and 10 aspheric C-flex 970 C IOLs (Rayner Intraocular Lenses Ltd., Hove, UK) of 26 diopters [D] using an optical bench (OptiSpheric, Trioptics, Germany). In all lenses, we evaluated the modulation transfer function (MTF) at 50 lp/mm and 100 lp/mm and the Strehl Ratio using a 3-mm (photopic) and 4.5-mm (mesopic) aperture. At 50 lp/mm, the MTF values were 0.713/0.805 (C-flex 570 C/C-flex 970 C) for a 3-mm aperture and 0.294/0.591 for a 4.5-mm aperture. At 100 lp/mm, the MTF values were 0.524/0.634 for a 3-mm aperture and 0.198/0.344 for a 4.5-mm aperture. The Strehl Ratio was 0.806/0.925 and 0.237/0.479 for a 3-mm and 4.5-mm aperture respectively. A Mann-Whitney U test revealed all intergroup differences to be statistically significant (p < 0.01). The aspheric IOL design achieved higher MTF values than the spherical design of the same IOL for both apertures. Moreover, the differences between the two designs of the IOL were more prominent for larger apertures. This suggests that the evaluated IOL provides enhanced optical quality to patients with larger pupils or working under mesopic conditions.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1992-01-01
The Transportable Applications Environment (TAE) Plus was built to support the construction of graphical user interfaces (GUI's) for highly interactive applications, such as real-time processing systems and scientific analysis systems. It is a general purpose portable tool that includes a 'What You See Is What You Get' WorkBench that allows user interface designers to layout and manipulate windows and interaction objects. The WorkBench includes both user entry objects (e.g., radio buttons, menus) and data-driven objects (e.g., dials, gages, stripcharts), which dynamically change based on values of realtime data. Discussed here is what TAE Plus provides, how the implementation has utilized state-of-the-art technologies within graphic workstations, and how it has been used both within and without NASA.
Digital optical correlator x-ray telescope alignment monitoring system
NASA Astrophysics Data System (ADS)
Lis, Tomasz; Gaskin, Jessica; Jasper, John; Gregory, Don A.
2018-01-01
The High-Energy Replicated Optics to Explore the Sun (HEROES) program is a balloon-borne x-ray telescope mission to observe hard x-rays (˜20 to 70 keV) from the sun and multiple astrophysical targets. The payload consists of eight mirror modules with a total of 114 optics that are mounted on a 6-m-long optical bench. Each mirror module is complemented by a high-pressure xenon gas scintillation proportional counter. Attached to the payload is a camera that acquires star fields and then matches the acquired field to star maps to determine the pointing of the optical bench. Slight misalignments between the star camera, the optical bench, and the telescope elements attached to the optical bench may occur during flight due to mechanical shifts, thermal gradients, and gravitational effects. These misalignments can result in diminished imaging and reduced photon collection efficiency. To monitor these misalignments during flight, a supplementary Bench Alignment Monitoring System (BAMS) was added to the payload. BAMS hardware comprises two cameras mounted directly to the optical bench and rings of light-emitting diodes (LEDs) mounted onto the telescope components. The LEDs in these rings are mounted in a predefined, asymmetric pattern, and their positions are tracked using an optical/digital correlator. The BAMS analysis software is a digital adaption of an optical joint transform correlator. The aim is to enhance the observational proficiency of HEROES while providing insight into the magnitude of mechanically and thermally induced misalignments during flight. Results from a preflight test of the system are reported.
Metalworking. A Bilingual Text = Trabajo en Metal. Un Texto Bilingue.
ERIC Educational Resources Information Center
Los Angeles Unified School District, CA. Div. of Career and Continuing Education.
This booklet is a course of instruction in metal working in a two-column, English-Spanish format. Following an introduction to metal working and a lesson on safety, the booklet contains 17 units organized in 2 parts. Part 1, bench metal work, covers metals, processes, and tools; cutting; filling; drilling; grinding; bending and shaping; threading;…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrews, M.K.
1999-05-10
Using ORNL information on the characterization of the tank waste sludges, SRTC performed extensive bench-scale vitrification studies using simulants. Several glass systems were tested to ensure the optimum glass composition (based on the glass liquidus temperature, viscosity and durability) is determined. This optimum composition will balance waste loading, melt temperature, waste form performance and disposal requirements. By optimizing the glass composition, a cost savings can be realized during vitrification of the waste. The preferred glass formulation was selected from the bench-scale studies and recommended to ORNL for further testing with samples of actual OR waste tank sludges.
2018-02-09
Pellets made from simulated lunar regolith, or dirt, and polymers are being used to test a Zero Launch Mass 3-D printer in the Swamp Works at NASA's Kennedy Space Center in Florida. The printer can be used for construction projects on the Moon and Mars, and even for troops in remote locations on Earth. Zero launch mass refers to the fact that the printer uses these pellets to prove that space explorers can use resources at their destination instead of taking everything with them, saving them launch mass and money. The group is working with Marshall Space Flight Center in Huntsville, Alabama, and the U.S. Army Corps of Engineers to develop a system that can 3-D print barracks in remote locations on Earth, using the resources they have where they are.
Neuromuscular Control During the Bench Press Movement in an Elite Disabled and Able-Bodied Athlete
Zwierzchowska, Anna; Maszczyk, Adam; Wilk, Michał; Stastny, Petr; Zając, Adam
2017-01-01
Abstract The disabled population varies significantly in regard to physical fitness, what is conditioned by the damage to the locomotor system. Recently there has been an increased emphasis on the role of competitive sport in enhancing health and the quality of life of individuals with disability. One of the sport disciplines of Paralympics is the flat bench press. The bench press is one of the most popular resistance exercises used for the upper body in healthy individuals. It is used not only by powerlifters, but also by athletes in most strength-speed oriented sport disciplines. The objective of the study was to compare neuromuscular control for various external loads (from 60 to 100% 1RM) during the flat bench press performed by an elite able-bodied athlete and an athlete with lower limb disability. The research project is a case study of two elite bench press athletes with similar sport results: an able-bodied athlete (M.W., age 34 years, body mass 103 kg, body height 1.72 m, 1RM in the flat bench press 200 kg) and a disabled athlete (M.T., age 31 years, body mass 92 kg, body height 1.70 m, 1RM in the flat bench press 190 kg). The activity was recorded for four muscles: pectoralis major (PM), anterior deltoid (AD), as well as for the lateral and long heads of the triceps brachii (TBlat and TBlong). The T-test revealed statistically significant differences between peak activity of all the considered muscles (AD with p = 0.001; PM with p = 0.001; TBlat with p = 0.0021 and TBlong with p = 0.002) between the 2 athletes. The analysis of peak activity differences of M.W and M.T. in relation to the load revealed statistically significant differences for load changes between: 60 to 100% 1RM (p = 0.007), 70 to 100% 1RM (p = 0.016) and 80 to 100% 1RM (p = 0.032). The flat bench press performed without legs resting firmly on the ground leads to the increased engagement of upper body muscles and to their greater activation. Isolated initial positions can be used to generate greater engagement of muscle groups during the bench press exercise and evoke their higher activation. PMID:29340001
Neuromuscular Control During the Bench Press Movement in an Elite Disabled and Able-Bodied Athlete.
Gołaś, Artur; Zwierzchowska, Anna; Maszczyk, Adam; Wilk, Michał; Stastny, Petr; Zając, Adam
2017-12-01
The disabled population varies significantly in regard to physical fitness, what is conditioned by the damage to the locomotor system. Recently there has been an increased emphasis on the role of competitive sport in enhancing health and the quality of life of individuals with disability. One of the sport disciplines of Paralympics is the flat bench press. The bench press is one of the most popular resistance exercises used for the upper body in healthy individuals. It is used not only by powerlifters, but also by athletes in most strength-speed oriented sport disciplines. The objective of the study was to compare neuromuscular control for various external loads (from 60 to 100% 1RM) during the flat bench press performed by an elite able-bodied athlete and an athlete with lower limb disability. The research project is a case study of two elite bench press athletes with similar sport results: an able-bodied athlete (M.W., age 34 years, body mass 103 kg, body height 1.72 m, 1RM in the flat bench press 200 kg) and a disabled athlete (M.T., age 31 years, body mass 92 kg, body height 1.70 m, 1RM in the flat bench press 190 kg). The activity was recorded for four muscles: pectoralis major (PM), anterior deltoid (AD), as well as for the lateral and long heads of the triceps brachii (TBlat and TBlong). The T-test revealed statistically significant differences between peak activity of all the considered muscles (AD with p = 0.001; PM with p = 0.001; TBlat with p = 0.0021 and TBlong with p = 0.002) between the 2 athletes. The analysis of peak activity differences of M.W and M.T. in relation to the load revealed statistically significant differences for load changes between: 60 to 100% 1RM (p = 0.007), 70 to 100% 1RM (p = 0.016) and 80 to 100% 1RM (p = 0.032). The flat bench press performed without legs resting firmly on the ground leads to the increased engagement of upper body muscles and to their greater activation. Isolated initial positions can be used to generate greater engagement of muscle groups during the bench press exercise and evoke their higher activation.
Contal, Olivier; Vignaux, Laurence; Combescure, Christophe; Pepin, Jean-Louis; Jolliet, Philippe; Janssens, Jean-Paul
2012-02-01
Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Use of a Terrestrial LIDAR Sensor for Drift Detection in Vineyard Spraying
Gil, Emilio; Llorens, Jordi; Llop, Jordi; Fàbregas, Xavier; Gallart, Montserrat
2013-01-01
The use of a scanning Light Detection and Ranging (LIDAR) system to characterize drift during pesticide application is described. The LIDAR system is compared with an ad hoc test bench used to quantify the amount of spray liquid moving beyond the canopy. Two sprayers were used during the field test; a conventional mist blower at two air flow rates (27,507 and 34,959 m3·h−1) equipped with two different nozzle types (conventional and air injection) and a multi row sprayer with individually oriented air outlets. A simple model based on a linear function was used to predict spray deposit using LIDAR measurements and to compare with the deposits measured over the test bench. Results showed differences in the effectiveness of the LIDAR sensor depending on the sprayed droplet size (nozzle type) and air intensity. For conventional mist blower and low air flow rate; the sensor detects a greater number of drift drops obtaining a better correlation (r = 0.91; p < 0.01) than for the case of coarse droplets or high air flow rate. In the case of the multi row sprayer; drift deposition in the test bench was very poor. In general; the use of the LIDAR sensor presents an interesting and easy technique to establish the potential drift of a specific spray situation as an adequate alternative for the evaluation of drift potential. PMID:23282583
Active vibration control on a quarter-car for cancellation of road noise disturbance
NASA Astrophysics Data System (ADS)
Belgacem, Walid; Berry, Alain; Masson, Patrice
2012-07-01
In this paper, a methodology is presented for the cancellation of road noise, from the analysis of vibration transmission paths for an automotive suspension to the design of an active control system using inertial actuators on a suspension to reduce the vibrations transmitted to the chassis. First, experiments were conducted on a Chevrolet Epica LS automobile on a concrete test track to measure accelerations induced on the suspension by the road. These measurements were combined with experimental Frequency Response Functions (FRFs) measured on a quarter-car test bench to reconstruct an equivalent three dimensional force applied on the wheel hub. Second, FRFs measured on the test bench between the three-dimensional driving force and forces at each suspension/chassis linkage were used to characterize the different transmission paths of vibration energy to the chassis. Third, an experimental model of the suspension was constructed to simulate the configuration of the active control system, using the primary (disturbance) FRFs and secondary (control) FRFs also measured on the test bench. This model was used to optimize the configuration of the control actuators and to evaluate the required forces. Finally, a prototype of an active suspension was implemented and measurements were performed in order to assess the performance of the control approach. A 4.6 dB attenuation on transmitted forces was obtained in the 50-250 Hz range.
GENERATION AND SIMULATION OF METALLIC PARTICULATE AIR POLLUTANTS BY ELECTRIC ARC SPRAYING
The report gives results of efforts to provide a generated output with an appropriate mass and concentration of fresh, dry, fine metal oxide particles for bench or pilot scale fine particulate collection research and development work. The work involved two electric arc aerosol ge...
Electrodeposition of metals and metal/cermet composites in low gravity
NASA Technical Reports Server (NTRS)
Riley, Clyde; Coble, Dwain; Maybee, George
1987-01-01
Electrodeposition experiments were carried out on the bench and a KC-135 aircraft at 0.01 g in anticipation of microgravity flights on NASA's Space Transportation System Shuttle. Experimental results obtained by interferometry compare concentration gradients as a function of time in the vicinity of a reducing electrode (cathode) for Cu(+2) and Co(+2) electrodeposition cells. No difference was found between bench and 0.01 g produced gradients for a .1M CuSO4 cell, but a significant difference was noted between the gradients in a 1M CoSO4 cell even though the bench cells were operated in a nonconvecting shielded (cathode over anode) mode. The gradient for Co(+2) depletion produced at 0.01 g was greater and the entire layer was thicker than found on the bench. Neutral buoyancy/matched density codeposition experiments were performed on the bench in an attempt to physically duplicate the results of metal/cermet codepositions in microgravity. Polystyrene spheres with average diameter 11.8 microns and density approximately matching that of 1M CoSO4 were utilized to emulate nonsedimenting cermets in microgravity. The cells were operated in a shielded convectionless mode. Comparison with literature data on codeposition with stirred cells indicate significant improvement in volume percent neutral occluded in the depositing metal matrix. A multicell electrodeposition flight apparatus that has been designed, constructed and is undergoing testing is discussed.
Tucci, Helga T; Ciol, Marcia A; de Araújo, Rodrigo C; de Andrade, Rodrigo; Martins, Jaqueline; McQuade, Kevin J; Oliveira, Anamaria S
2011-07-01
Controlled laboratory study. To assess the activation of 7 shoulder muscles under 2 closed kinetic chain (CKC) tasks for the upper extremity using submaximal isometric effort, thus providing relative quantification of muscular isometric effort for these muscles across the CKC exercises, which may be applied to rehabilitation protocols for individuals with shoulder weakness. CKC exercises favor joint congruence, reduce shear load, and promote joint dynamic stability. Additionally, knowledge about glenohumeral and periscapular muscle activity elicited during CKC exercises may help clinicians to design protocols for shoulder rehabilitation. Using surface electromyography, activation level was measured across 7 shoulder muscles in 20 healthy males, during the performance of a submaximal isometric wall press and bench press. Signals were normalized to the maximal voluntary isometric contraction, and, using paired t tests, data were analyzed between the exercises for each muscle. Compared to the wall press, the bench press elicited higher activity for most muscles, except for the upper trapezius. Levels of activity were usually low but were above 20% maximal voluntary isometric contraction for the serratus anterior on both tasks, and for the long head triceps brachii on the bench press. Both the bench press and wall press, as performed in this study, led to relatively low EMG activation levels for the muscles measured and may be considered for use in the early phases of rehabilitation.
NASA Astrophysics Data System (ADS)
Qiu, Feng; Michizono, Shinichiro; Miura, Takako; Matsumoto, Toshihiro; Liu, Na; Wibowo, Sigit Basuki
2018-03-01
A Low-level radio-frequency (LLRF) control systems is required to regulate the rf field in the rf cavity used for beam acceleration. As the LLRF system is usually complex, testing of the basic functions or control algorithms of this system in real time and in advance of beam commissioning is strongly recommended. However, the equipment necessary to test the LLRF system, such as superconducting cavities and high-power rf sources, is very expensive; therefore, we have developed a field-programmable gate array (FPGA)-based cavity simulator as a substitute for real rf cavities. Digital models of the cavity and other rf systems are implemented in the FPGA. The main components include cavity baseband models for the fundamental and parasitic modes, a mechanical model of the Lorentz force detuning, and a model of the beam current. Furthermore, in our simulator, the disturbance model used to simulate the power-supply ripples and microphonics is also carefully considered. Based on the presented cavity simulator, we have established an LLRF system test bench that can be applied to different cavity operational conditions. The simulator performance has been verified by comparison with real cavities in KEK accelerators. In this paper, the development and implementation of this cavity simulator is presented first, and the LLRF test bench based on the presented simulator is constructed. The results are then compared with those for KEK accelerators. Finally, several LLRF applications of the cavity simulator are illustrated.
40 CFR 264.17 - General requirements for ignitable, reactive, or incompatible wastes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (e.g., from heat-producing chemical reactions), and radiant heat. While ignitable or reactive waste... scientific or engineering literature, data from trial tests (e.g., bench scale or pilot scale tests), waste...
Conception of a test bench to generate known and controlled conditions of refrigerant mass flow.
Martins, Erick F; Flesch, Carlos A; Flesch, Rodolfo C C; Borges, Maikon R
2011-07-01
Refrigerant compressor performance tests play an important role in the evaluation of the energy characteristics of the compressor, enabling an increase in the quality, reliability, and efficiency of these products. Due to the nonexistence of a refrigerating capacity standard, it is common to use previously conditioned compressors for the intercomparison and evaluation of the temporal drift of compressor performance test panels. However, there are some limitations regarding the use of these specific compressors as standards. This study proposes the development of a refrigerating capacity standard which consists of a mass flow meter and a variable-capacity compressor, whose speed is set based on the mass flow rate measured by the meter. From the results obtained in the tests carried out on a bench specifically developed for this purpose, it was possible to validate the concept of a capacity standard. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
Development of circumferential seal for helicopter transmissions: Results of bench and flight tests
NASA Technical Reports Server (NTRS)
Strom, T. N.; Ludwig, L. P.
1975-01-01
A modified circumferential segmented ring seal was designed for direct replacement of a helicopter transmission elastomeric lip seal operating on a shaft diameter of 13.91 centimeters (5.481 in.) at sliding velocities to 52.48 m/sec (10 330 ft/min). The modifications involved the garter spring tension, shaft roundness, seal housing flatness, and pumping grooves to inhibit leakage. Operation of the seals in bench tests under simulated helicopter transmission conditions revealed that the seal leakage rate was within acceptable limits and that the wear rate was negligible. The low leakage and wear rates were confirmed in flight tests of 600 and 175 hours (sliding speed, 48.11 m/sec (9470 ft/min)). An additional 200 hours of air worthiness qualification testing (aircraft tie down) demonstrated that the seal can operate at the advanced sliding conditions of 52.48 m/sec (10 330 ft/min).
NASA Astrophysics Data System (ADS)
Zorzetti, Silvia; Fanucci, Luca; Galindo Muñoz, Natalia; Wendt, Manfred
2015-09-01
The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-μm regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical centre of a 15 GHz cavity beam position monitor (BPM) to the magnetic centre of the main beam quadrupole is initiated. Of particular importance is the design of a specific test bench to study the stretched-wire setup for the CLIC Test Facility (CTF3) BPM, focusing on the aspects of microwave signal excitation, transmission and impedance-matching, as well as the mechanical setup and reproducibility of the measurement method.
NASA Astrophysics Data System (ADS)
Dufour, Marc L.; Bisaillon, Charles-Etienne; Lamouche, Guy; Vergnole, Sebastien; Hewko, Mark; D'Amours, Frédéric; Padioleau, Christian; Sowa, Michael
2011-03-01
The Industrial Material Institute (IMI) together with the Institute for Biodiagnostic (IBD) has developed its own optical catheters for cardiovascular imaging applications. Those catheters have been used experimentally in the in vitro coronary artery model of the Langendorff beating heart and in a percutaneous coronary intervention procedure in a porcine model. For some catheter designs, non-uniform rotational distortion (NURD) can be observed as expected from past experience with intra-vascular ultrasound (IVUS) catheters. A two-dimensional (2D) coronary artery test bench that simulates the path into the coronary arteries has been developed. The presence or absence of NURD can be assessed with the test bench using a custom-built cardiovascular Optical Coherence Tomography (OCT) imaging system. A square geometry instead of the circular shape of an artery is used to simulate the coronary arteries. Thereby, it is easier to visualize NURD when it is present. The accumulated torsion induced by the friction on the catheter is measured along the artery path. NURD is induced by the varying friction force that is balanced by the accumulated torsion force. The pullback force is measured and correlated with NURD observed in the 2D test bench. Finally, a model is presented to help understanding the mechanical constraint that leads to the friction force variations.
Muscle synergies during bench press are reliable across days.
Kristiansen, Mathias; Samani, Afshin; Madeleine, Pascal; Hansen, Ernst Albin
2016-10-01
Muscle synergies have been investigated during different types of human movement using nonnegative matrix factorization. However, there are not any reports available on the reliability of the method. To evaluate between-day reliability, 21 subjects performed bench press, in two test sessions separated by approximately 7days. The movement consisted of 3 sets of 8 repetitions at 60% of the three repetition maximum in bench press. Muscle synergies were extracted from electromyography data of 13 muscles, using nonnegative matrix factorization. To evaluate between-day reliability, we performed a cross-correlation analysis and a cross-validation analysis, in which the synergy components extracted in the first test session were recomputed, using the fixed synergy components from the second test session. Two muscle synergies accounted for >90% of the total variance, and reflected the concentric and eccentric phase, respectively. The cross-correlation values were strong to very strong (r-values between 0.58 and 0.89), while the cross-validation values ranged from substantial to almost perfect (ICC3, 1 values between 0.70 and 0.95). The present findings revealed that the same general structure of the muscle synergies was present across days and the extraction of muscle synergies is thus deemed reliable. Copyright © 2016 Elsevier Ltd. All rights reserved.
Forbes, Scott C; Candow, Darren G; Little, Jonathan P; Magnus, Charlene; Chilibeck, Philip D
2007-10-01
The purpose of this study was to determine the effects of Red Bull energy drink on Wingate cycle performance and muscle endurance. Healthy young adults (N = 15, 11 men, 4 women, 21 +/- 5 y old) participated in a crossover study in which they were randomized to supplement with Red Bull (2 mg/kg body mass of caffeine) or isoenergetic, isovolumetric, noncaffeinated placebo, separated by 7 d. Muscle endurance (bench press) was assessed by the maximum number of repetitions over 3 sets (separated by 1-min rest intervals) at an intensity corresponding to 70% of baseline 1-repetition maximum. Three 30-s Wingate cycling tests (load = 0.075 kp/kg body mass), with 2 min recovery between tests, were used to assess peak and average power output. Red Bull energy drink significantly increased total bench-press repetitions over 3 sets (Red Bull = 34 +/- 9 vs. placebo = 32 +/- 8, P %%%lt; 0.05) but had no effect on Wingate peak or average power (Red Bull = 701 +/- 124 W vs. placebo = 700 +/- 132 W, Red Bull = 479 +/- 74 W vs. placebo = 471 +/- 74 W, respectively). Red Bull energy drink significantly increased upper body muscle endurance but had no effect on anaerobic peak or average power during repeated Wingate cycling tests in young healthy adults.
Ultrafine particle emission characteristics of diesel engine by on-board and test bench measurement.
Huang, Cheng; Lou, Diming; Hu, Zhiyuan; Tan, Piqiang; Yao, Di; Hu, Wei; Li, Peng; Ren, Jin; Chen, Changhong
2012-01-01
This study investigated the emission characteristics of ultrafine particles based on test bench and on-board measurements. The bench test results showed the ultrafine particle number concentration of the diesel engine to be in the range of (0.56-8.35) x 10(8) cm(-3). The on-board measurement results illustrated that the ultrafine particles were strongly correlated with changes in real-world driving cycles. The particle number concentration was down to 2.0 x 10(6) cm(-3) and 2.7 x 10(7) cm(-3) under decelerating and idling operations and as high as 5.0 x 10(8) cm(-3) under accelerating operation. It was also indicated that the particle number measured by the two methods increased with the growth of engine load at each engine speed in both cases. The particle number presented a "U" shaped distribution with changing speed at high engine load conditions, which implies that the particle number will reach its lowest level at medium engine speeds. The particle sizes of both measurements showed single mode distributions. The peak of particle size was located at about 50-80 nm in the accumulation mode particle range. Nucleation mode particles will significantly increase at low engine load operations like idling and decelerating caused by the high concentration of unburned organic compounds.
Advanced very high resolution radiometer
NASA Technical Reports Server (NTRS)
1976-01-01
The advanced very high resolution radiometer development program is considered. The program covered the design, construction, and test of a breadboard model, engineering model, protoflight model, mechanical structural model, and a life test model. Special bench test and calibration equipment was also developed for use on the program.
New projects developed by COMOTI in gas industry
NASA Astrophysics Data System (ADS)
Nitulescu, Marian; Silivestru, Valentin; Toma, Niculae; Slujitoru, Cristian; Petrescu, Valentin; Leahu, Mihai; Oniga, Ciprian; Ulici, Gheorghe
2015-08-01
The paper aims to present two new projects developed by the Romanian Research and Development Institute for Gas Turbines (COMOTI) in partnership with City University of London and GHH-Rand Germany, in the field of screw compressors/expanders. COMOTI passed, in recent years, from being a GHH-Rand licensed manufacturer for a range of oil-injected screw compressors, of CU type, to a new phase of range diversification, approaching screw compressors with a maximum discharge pressure of 45 bara. So, in cooperation with City University and GHH-Rand we design, manufacture and test, with air, in COMOTI test bench the new type of screw compressor named CHP 220. Also, the cooperation with GHH-Rand has resulted in the design, manufacture and air testing on the test bench, and then gas testing - in a gas compression station - for an electric generator driven by a screw expander. This paper presents how the tests were carried out, the experimental data and the interpretation of results
Characterizing the Influence of Abstraction in Full-Scale Wind Turbine Nacelle Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schkoda, Ryan; Bibo, Amin; Guo, Yi
2016-08-21
In recent years, there has been a growing interest in full-scale wind turbine nacelle testing to complement individual component testing. As a result, several wind turbine nacelle test benches have been built to perform such testing with the intent of loading the integrated components as they are in the field. However, when mounted on a test bench the nacelle is not on the top of a tower and does not have blades attached to it - this is a form of abstraction. This paper aims to quantify the influence of such an abstraction on the dynamic response of the nacellemore » through a series of simulation case studies. The responses of several nacelle components are studied including the main bearing, main shaft, gearbox supports, generator, and yaw bearing interface. Results are presented to highlight the differences in the dynamic response of the nacelle caused by the abstraction. Additionally, the authors provide recommendations for mitigating the effects of the abstraction.« less
Characterizing the Influence of Abstraction in Full-Scale Wind Turbine Nacelle Testing: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schkoda, Ryan; Bibo, Amin; Guo, Yi
2016-08-01
In recent years, there has been a growing interest in full-scale wind turbine nacelle testing to complement individual component testing. As a result, several wind turbine nacelle test benches have been built to perform such testing with the intent of loading the integrated components as they are in the field. However, when mounted on a test bench the nacelle is not on the top of a tower and does not have blades attached to it--this is a form of abstraction. This paper aims to quantify the influence of such an abstraction on the dynamic response of the nacelle through amore » series of simulation case studies. The responses of several nacelle components are studied including the main bearing, main shaft, gearbox supports, generator, and yaw bearing interface. Results are presented to highlight the differences in the dynamic response of the nacelle caused by the abstraction. Additionally, the authors provide recommendations for mitigating the effects of the abstraction.« less
Borgna, F; Ballan, M; Corradetti, S; Vettorato, E; Monetti, A; Rossignoli, M; Manzolaro, M; Scarpa, D; Mazzi, U; Realdon, N; Andrighetto, A
2017-09-01
Radiopharmaceuticals represent a fundamental tool for nuclear medicine procedures, both for diagnostic and therapeutic purposes. The present work aims to explore the Isotope Separation On-Line (ISOL) technique for the production of carrier-free radionuclides for nuclear medicine at SPES, a nuclear physics facility under construction at INFN-LNL. Stable ion beams of strontium, yttrium and iodine were produced using the SPES test bench (Front-End) to simulate the production of 89 Sr, 90 Y, 125 I and 131 I and collected with good efficiency on suitable targets. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nano-JASMINE: use of AGIS for the next astrometric satellite
NASA Astrophysics Data System (ADS)
Yamada, Y.; Gouda, N.; Lammers, U.
The core data reduction for the Nano-JASMINE mission is planned to be done with Gaia's Astrometric Global Iterative Solution (AGIS). The collaboration started at 2007 prompted by Uwe Lammers' proposal. In addition to similar design and operating principles of the two missions, this is possible thanks to the encapsulation of all Gaia-specific aspects of AGIS in a Parameter Database. Nano-JASMINE will be the test bench for Gaia AGIS software. We present this idea in detail and the necessary practical steps to make AGIS work with Nano-JASMINE data. We also show the key mission parameters, goals, and status of the data reduction for the Nano-JASMINE.
An in vitro test bench reproducing coronary blood flow signals.
Chodzyński, Kamil Jerzy; Boudjeltia, Karim Zouaoui; Lalmand, Jacques; Aminian, Adel; Vanhamme, Luc; de Sousa, Daniel Ribeiro; Gremmo, Simone; Bricteux, Laurent; Renotte, Christine; Courbebaisse, Guy; Coussement, Grégory
2015-08-07
It is a known fact that blood flow pattern and more specifically the pulsatile time variation of shear stress on the vascular wall play a key role in atherogenesis. The paper presents the conception, the building and the control of a new in vitro test bench that mimics the pulsatile flows behavior based on in vivo measurements. An in vitro cardiovascular simulator is alimented with in vivo constraints upstream and provided with further post-processing analysis downstream in order to mimic the pulsatile in vivo blood flow quantities. This real-time controlled system is designed to perform real pulsatile in vivo blood flow signals to study endothelial cells' behavior under near physiological environment. The system is based on an internal model controller and a proportional-integral controller that controls a linear motor with customized piston pump, two proportional-integral controllers that control the mean flow rate and temperature of the medium. This configuration enables to mimic any resulting blood flow rate patterns between 40 and 700 ml/min. In order to feed the system with reliable periodic flow quantities in vivo measurements were performed. Data from five patients (1 female, 4 males; ages 44-63) were filtered and post-processed using the Newtonian Womersley's solution. These resulting flow signals were compared with 2D axisymmetric, numerical simulation using a Carreau non-Newtonian model to validate the approximation of a Newtonian behavior. This in vitro test bench reproduces the measured flow rate time evolution and the complexity of in vivo hemodynamic signals within the accuracy of the relative error below 5%. This post-processing method is compatible with any real complex in vivo signal and demonstrates the heterogeneity of pulsatile patterns in coronary arteries among of different patients. The comparison between analytical and numerical solution demonstrate the fair quality of the Newtonian Womersley's approximation. Therefore, Womersley's solution was used to calculate input flow rate for the in vitro test bench.
Bianco, Antonino; Filingeri, Davide; Paoli, Antonio; Palma, Antonio
2015-04-01
The aim of this study was to evaluate a new method to perform the one repetition maximum (1RM) bench press test, by combining previously validated predictive and practical procedures. Eight young male and 7 females participants, with no previous experience of resistance training, performed a first set of repetitions to fatigue (RTF) with a workload corresponding to ⅓ of their body mass (BM) for a maximum of 25 repetitions. Following a 5-min recovery period, a second set of RTF was performed with a workload corresponding to ½ of participants' BM. The number of repetitions performed in this set was then used to predict the workload to be used for the 1RM bench press test using Mayhew's equation. Oxygen consumption, heart rate and blood lactate were monitored before, during and after each 1RM attempt. A significant effect of gender was found on the maximum number of repetitions achieved during the RTF set performed with ½ of participants' BM (males: 25.0 ± 6.3; females: 11.0x± 10.6; t = 6.2; p < 0.001). The 1RM attempt performed with the workload predicted by Mayhew's equation resulted in females performing 1.2 ± 0.7 repetitions, while males performed 4.8 ± 1.9 repetitions. All participants reached their 1RM performance within 3 attempts, thus resulting in a maximum of 5 sets required to successfully perform the 1RM bench press test. We conclude that, by combining previously validated predictive equations with practical procedures (i.e. using a fraction of participants' BM to determine the workload for an RTF set), the new method we tested appeared safe, accurate (particularly in females) and time-effective in the practical evaluation of 1RM performance in inexperienced individuals. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westendorf, Tiffany; Buddle, Stanlee; Caraher, Joel
The objective of this project is to design and build a bench-scale process for a novel phase-changing aminosilicone-based CO 2-capture solvent. The project will establish scalability and technical and economic feasibility of using a phase-changing CO 2-capture absorbent for post-combustion capture of CO 2 from coal-fired power plants. The U.S. Department of Energy’s goal for Transformational Carbon Capture Technologies is the development of technologies available for demonstration by 2025 that can capture 90% of emitted CO 2 with at least 95% CO 2 purity for less than $40/tonne of CO 2 captured. In the first budget period of the project,more » the bench-scale phase-changing CO2 capture process was designed using data and operating experience generated under a previous project (ARPA-e project DE-AR0000084). Sizing and specification of all major unit operations was completed, including detailed process and instrumentation diagrams. The system was designed to operate over a wide range of operating conditions to allow for exploration of the effect of process variables on CO 2 capture performance. In the second budget period of the project, individual bench-scale unit operations were tested to determine the performance of each of each unit. Solids production was demonstrated in dry simulated flue gas across a wide range of absorber operating conditions, with single stage CO 2 conversion rates up to 75mol%. Desorber operation was demonstrated in batch mode, resulting in desorption performance consistent with the equilibrium isotherms for GAP-0/CO 2 reaction. Important risks associated with gas humidity impact on solids consistency and desorber temperature impact on thermal degradation were explored, and adjustments to the bench-scale process were made to address those effects. Corrosion experiments were conducted to support selection of suitable materials of construction for the major unit operations in the process. The bench scale unit operations were assembled into a continuous system to support steady state system testing. In the third budget period of the project, continuous system testing was conducted, including closed-loop operation of the absorber and desober systems. Slurries of GAP-0/GAP-0 carbamate/water mixtures produced in the absorber were pumped successfully to the desorber unit, and regenerated solvent was returned to the absorber. A techno-economic analysis, EH&S risk assessment, and solvent manufacturability study were completed.« less
40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)
Code of Federal Regulations, 2014 CFR
2014-07-01
... VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging bench with an...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fitzgerald, David; Vidal, Rafael; Russell, Tania
2014-12-31
The results of the preliminary environmental, health and safety (EH&S) risk assessment for an enzyme-activated potassium carbonate (K2CO3) solution post-combustion CO2 capture (PCC) plant, integrated with a subcritical pulverized coal (PC) power plant, are presented. The expected emissions during normal steady-state operation have been estimated utilizing models of the PCC plant developed in AspenTech’s AspenPlus® software, bench scale test results from the University of Kentucky, and industrial experience of emission results from a slipstream PCC plant utilizing amine based solvents. A review of all potential emission species and their sources was undertaken that identified two credible emission sources, the absorbermore » off-gas that is vented to atmosphere via a stack and the waste removed from the PCC plant in the centrifuge used to reclaim enzyme and solvent. The conditions and compositions of the emissions were calculated and the potential EH&S effects were considered as well as legislative compliance requirements. Potential mitigation methods for emissions during normal operation have been proposed and solutions to mitigate uncontrolled releases of species have been considered. The potential emissions were found to pose no significant EH&S concerns and were compliant with the Federal legislation reviewed. The limitations in predicting full scale plant performance from bench scale tests have been noted and further work on a larger scale test unit is recommended to reduce the level of uncertainty.« less
NASA Astrophysics Data System (ADS)
Macedo, Milton P.; Correia, C. M. B. A.
2013-04-01
This work aims at showing the applicability of a scanning-stage bench-microscope in bright-field reflection mode for wirebonding inspection of integrated circuits (IC) as well as quality assurance of tracks in printed circuit boards (PCB). The main issues of our laboratorial prototype arise from the use of a linear image sensor taking advantage of its geometry to achieve lower acquisition time in comparison to traditional (pinhole) confocal approach. The use of a slit-detector is normally related to resolution degradation for details parallel to sensor. But an improvement will surely arise using light distribution along line pixels of the sensor which establishes a great advantage in comparison to (pure) slit detectors. The versatility of this bench-microscope affords excellent means to develop and test algorithms. Those to improve lateral resolution isotropy as well as image visualization and 3D mesh reconstruction under different setups namely illumination modes. Based on the results of these tests tests both wide-field illumination and parallel slit illumination and detection configurations were used in these two applications. Results from IC wire-bonding show the ability of the system to extract 3D information. A comparison of auto-focus images and 3D profiles obtained using different 3D reconstruction algorithms as well as a method for the determination of the diameter of the bond wire are presented. Measurements of PCB track width and thickness were performed and the comparison of these results from both longitudinal and transverse tracks stress the limitations of a lower spatial sampling rate induced by the resolution of object stage positioners.
Research on EHN additive on the diesel engine combustion characteristics in plateau environment
NASA Astrophysics Data System (ADS)
Sun, Zhixin; Li, Ruoting; Wang, Xiancheng; Hu, Chuan
2017-03-01
Aiming at the combustion deterioration problem of diesel engine in plateau environment, a bench test was carried out for the effects of EHN additive on combustion characteristics of the diesel engine with intake pressure of 0.68 kPa. Test results showed that with the full load working condition of 1 400 r/min: Cylinder pressure and pressure uprising rate decreased with EHN additive added in, mechanical load on the engine could be relieved; peak value of the heat release rate decreased and its occurrence advanced, ignition delay and combustion duration were shortened; cylinder temperature and exhaust gas temperature declined, thermal load on the engine could be relieved, output torque increased while specific oil consumption decreased, and effective thermal efficiency of diesel engine increased.
Angotzi, Gian Nicola; Boi, Fabio; Zordan, Stefano; Bonfanti, Andrea; Vato, Alessandro
2014-01-01
A portable 16-channels microcontroller-based wireless system for a bi-directional interaction with the central nervous system is presented in this work. The device is designed to be used with freely behaving small laboratory animals and allows recording of spontaneous and evoked neural activity wirelessly transmitted and stored on a personal computer. Biphasic current stimuli with programmable duration, frequency and amplitude may be triggered in real-time on the basis of the recorded neural activity as well as by the animal behavior within a specifically designed experimental setup. An intuitive graphical user interface was developed to configure and to monitor the whole system. The system was successfully tested through bench tests and in vivo measurements on behaving rats chronically implanted with multi-channels microwire arrays. PMID:25096831
The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance
Saeterbakken, Atle Hole; Mo, Dag-André; Scott, Suzanne; Andersen, Vidar
2017-01-01
Abstract The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-significant differences in activation were observed between the three bench positions with the exception of 58.5-62.6% lower triceps brachii activation, but 48.3-68.7% greater biceps brachii activation in the inclined bench compared with the flat and declined bench position. Comparing the three grip widths, non-significant differences in activations were observed, with the exception of 25.9-30.5% lower EMG activity in the biceps brachii using a narrow grip, compared to the medium and wide grip conditions. The 6-RM loads were 5.8-11.1% greater using a medium and wide grip compared to narrow grip width and 18.5-21.5% lower in the inclined bench position compared with flat and declined. Comparing the EMG activity during the competition bench press style with either the inclined and declined bench position (wide grip) or using a narrow and medium grip (flat bench), only resulted in different EMG activity in the biceps- and triceps brachii. The 6RM loads varied with each bench press variation and we recommend the use of a wide grip on a flat bench during high load hypertrophy training to bench press athletes. PMID:28713459
The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance.
Saeterbakken, Atle Hole; Mo, Dag-André; Scott, Suzanne; Andersen, Vidar
2017-06-01
The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-significant differences in activation were observed between the three bench positions with the exception of 58.5-62.6% lower triceps brachii activation, but 48.3-68.7% greater biceps brachii activation in the inclined bench compared with the flat and declined bench position. Comparing the three grip widths, non-significant differences in activations were observed, with the exception of 25.9-30.5% lower EMG activity in the biceps brachii using a narrow grip, compared to the medium and wide grip conditions. The 6-RM loads were 5.8-11.1% greater using a medium and wide grip compared to narrow grip width and 18.5-21.5% lower in the inclined bench position compared with flat and declined. Comparing the EMG activity during the competition bench press style with either the inclined and declined bench position (wide grip) or using a narrow and medium grip (flat bench), only resulted in different EMG activity in the biceps- and triceps brachii. The 6RM loads varied with each bench press variation and we recommend the use of a wide grip on a flat bench during high load hypertrophy training to bench press athletes.
Pattern Generator for Bench Test of Digital Boards
NASA Technical Reports Server (NTRS)
Berkun, Andrew C.; Chu, Anhua J.
2012-01-01
All efforts to develop electronic equipment reach a stage where they need a board test station for each board. The SMAP digital system consists of three board types that interact with each other using interfaces with critical timing. Each board needs to be tested individually before combining into the integrated digital electronics system. Each board needs critical timing signals from the others to be able to operate. A bench test system was developed to support test of each board. The test system produces all the outputs of the control and timing unit, and is delivered much earlier than the timing unit. Timing signals are treated as data. A large file is generated containing the state of every timing signal at any instant. This file is streamed out to an IO card, which is wired directly to the device-under-test (DUT) input pins. This provides a flexible test environment that can be adapted to any of the boards required to test in a standalone configuration. The problem of generating the critical timing signals is then transferred from a hardware problem to a software problem where it is more easily dealt with.
79. SITE INSTRUMENTATION: INTERIOR OF INSTRUMENTATION BUNKER AT 800 WEST, ...
79. SITE INSTRUMENTATION: INTERIOR OF INSTRUMENTATION BUNKER AT 800 WEST, WITH WOODEN WORK BENCH - White Sands Missile Range, Trinity Site, Vicinity of Routes 13 & 20, White Sands, Dona Ana County, NM
High Speed Digital Camera Technology Review
NASA Technical Reports Server (NTRS)
Clements, Sandra D.
2009-01-01
A High Speed Digital Camera Technology Review (HSD Review) is being conducted to evaluate the state-of-the-shelf in this rapidly progressing industry. Five HSD cameras supplied by four camera manufacturers participated in a Field Test during the Space Shuttle Discovery STS-128 launch. Each camera was also subjected to Bench Tests in the ASRC Imaging Development Laboratory. Evaluation of the data from the Field and Bench Tests is underway. Representatives from the imaging communities at NASA / KSC and the Optical Systems Group are participating as reviewers. A High Speed Digital Video Camera Draft Specification was updated to address Shuttle engineering imagery requirements based on findings from this HSD Review. This draft specification will serve as the template for a High Speed Digital Video Camera Specification to be developed for the wider OSG imaging community under OSG Task OS-33.
Assessment of Water Quality of Runoff from Sealed Asphalt Surfaces
This report discusses the results of runoff tests from recently-sealed asphalt surfaces conducted at EPA's Urban Watershed Research Facility (UWRF) in Edison, New Jersey. Both bench-scale panels and full-scale test plots were evaluated. Full-scale tests were performed on an asp...
Current chemical dispersant effectiveness tests for product selection are commonly performed with bench-scale testing apparatus. However, for the assessment of oil dispersant effectiveness under real sea state conditions, test protocols are required to have hydrodynamic conditio...
Biofiltration of odors, toxics and volatile organic compounds from publicly owned treatment works
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webster, T.S.; Devinny, J.S.; Torres, E.M.
1996-12-31
Increasing federal and state regulation has made it necessary to apply air pollution control measures at publicly owned treatment works (POTWs). Traditional control technologies may not be suitable for treating the low and variable contaminant concentrations often found in POTW off-gases. An alternative control technology, biofiltration, was studied. An experiment using bench- and pilot-scale reactors established optimal operating conditions for a full-scale conceptual design. The waste airstream contained ppmv levels of hydrogen sulfide and ppbv levels of specific volatile organic compounds (VOCs). Granular activated carbon (GAC) and yard waste compost (YWG) were tested as possible biofilter media with and withoutmore » pH control. The 16-month field study bench reactors achieved 99% removal of hydrogen sulfide, 53 to 98% removal of aromatic hydrocarbons, 37 to 95% removal of aldehydes and ketones, and 0 to 85% removal of chlorinated compounds. The GAC and YWC pilot reactors removed more than 80% and 65% of the total VOCs at 17 second and 70 second empty bed retention times, respectively. The YWC reactors performed poorly at empty bed retention times of 30 and 45 seconds, removing less than 40% of total VOCs. Declining pH had little negative effect on contaminant removal, suggesting costly control measures may not be necessary. Biofiltration appears to be a feasible alternative to traditional control technologies in treating off-gases from POTWs. 13 refs., 3 figs., 4 tabs.« less
Scale-down/scale-up studies leading to improved commercial beer fermentation.
Nienow, Alvin W; Nordkvist, Mikkel; Boulton, Christopher A
2011-08-01
Scale-up/scale-down techniques are vital for successful and safe commercial-scale bioprocess design and operation. An example is given in this review of recent studies related to beer production. Work at the bench scale shows that brewing yeast is not compromised by mechanical agitation up to 4.5 W/kg; and that compared with fermentations mixed by CO(2) evolution, agitation ≥ 0.04 W/kg is able to reduce fermentation time by about 20%. Work at the commercial scale in cylindroconical fermenters shows that, without mechanical agitation, most of the yeast sediments into the cone for about 50% of the fermentation time, leading to poor temperature control. Stirrer mixing overcomes these problems and leads to a similar reduction in batch time as the bench-scale tests and greatly reduces its variability, but is difficult to install in extant fermenters. The mixing characteristics of a new jet mixer, a rotary jet mixer, which overcomes these difficulties, are reported, based on pilot-scale studies. This change enables the advantages of stirring to be achieved at the commercial scale without the problems. In addition, more of the fermentable sugars are converted into ethanol. This review shows the effectiveness of scale-up/scale-down studies for improving commercial operations. Suggestions for further studies are made: one concerning the impact of homogenization on the removal of vicinal diketones and the other on the location of bubble formation at the commercial scale. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Neam, Douglas C.; Gerber, John D.
1992-01-01
The stringent stability requirements of the Corrective Optics Space Telescope Axial Replacement (COSTAR) necessitates a Deployable Optical Bench (DOB) with both a low CTE and high resonant frequency. The DOB design consists of a monocoque thin shell structure which marries metallic machined parts with graphite epoxy formed structure. Structural analysis of the DOB has been integrated into the laminate design and optimization process. Also, the structural analytical results are compared with vibration and thermal test data to assess the reliability of the analysis.
Balsalobre-Fernández, Carlos; Marchante, David; Muñoz-López, Mario; Jiménez, Sergio L
2018-01-01
The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load-velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg -1 = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75-100% 1RM), while the mean velocity of the barbell was registered using a linear transducer (LT) and Powerlift. Results showed a very high correlation between the LT and the app (r = 0.94, SEE = 0.028 m · s -1 ) for the measurement of mean velocity. Bland-Altman plots (R 2 = 0.011) and intraclass correlation coefficient (ICC = 0.965) revealed a very high agreement between both devices. A systematic bias by which the app registered slightly higher values than the LT (P < 0.05; mean difference (SD) between instruments = 0.008 ± 0.03 m · s -1 ). Finally, actual and estimated 1RM using the app were highly correlated (r = 0.98, mean difference (SD) = 5.5 ± 9.6 kg, P < 0.05). The app was found to be highly valid and reliable in comparison with a LT. These findings could have valuable practical applications for strength and conditioning coaches who wish to measure barbell velocity in the bench-press exercise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Feng; Heldebrant, David J.; Mathias, Paul M.
This manuscript provides a detailed analysis of a continuous flow, bench scale study of the CO2BOL solvent platform with and without its Polarity Swing Assisted Regeneration (PSAR). This study encompassed four months of continuous flow testing of a candidate CO2BOL with a thermal regeneration and PSAR regeneration using decane antisolvent. In both regeneration schemes, steady state capture of >90 %CO2 was achieved using simulated flue gas at acceptable L/G ratios. Aspen Plus™ modeling was performed to assess process performance compared to previous equilibrium performance projections. This paper also includes net power projections, and comparisons to DOE’s Case 10 amine baseline.
Second International Workshop on Grid Simulator Testing of Wind Turbine
, Clemson University, USA Update on the FSU-CAPS Megawatt Scale Power Hardware in the Loop Laboratory Loop Based Anti-Islanding Testing of PV Converters-Michael Steurer, Florida State University, USA Closed-Loop Control of Modern Test Benches Advanced Control Techniques for Dynamic Testing of Wind
Assessment and monitoring of ballistic and maximal upper-body strength qualities in athletes.
Young, Kieran P; Haff, G Gregory; Newton, Robert U; Gabbett, Tim J; Sheppard, Jeremy M
2015-03-01
To evaluate whether the dynamic strength index (DSI: ballistic peak force/isometric peak force) could be effectively used to guide specific training interventions and detect training-induced changes in maximal and ballistic strength. Twenty-four elite male athletes were assessed in the isometric bench press and a 45% 1-repetition-maximum (1RM) ballistic bench throw using a force plate and linear position transducer. The DSI was calculated using the peak force values obtained during the ballistic bench throw and isometric bench press. Athletes were then allocated into 2 groups as matched pairs based on their DSI and strength in the 1RM bench press. Over the 5 wk of training, athletes performed either high-load (80-100% 1RM) bench press or moderate-load (40-55% 1RM) ballistic bench throws. The DSI was sensitive to disparate training methods, with the bench-press group increasing isometric bench-press peak force (P=.035, 91% likely), and the ballistic-bench-throw group increasing bench-throw peak force to a greater extent (P≤.001, 83% likely). A significant increase (P≤.001, 93% likely) in the DSI was observed for both groups. The DSI can be used to guide specific training interventions and can detect training-induced changes in isometric bench-press and ballistic bench-throw peak force over periods as short as 5 wk.
Simulant Development for LAWPS Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, Renee L.; Schonewill, Philip P.; Burns, Carolyn A.
2017-05-23
This report describes simulant development work that was conducted to support the technology maturation of the LAWPS facility. Desired simulant physical properties (density, viscosity, solids concentration, solid particle size), sodium concentrations, and general anion identifications were provided by WRPS. The simulant recipes, particularly a “nominal” 5.6M Na simulant, are intended to be tested at several scales, ranging from bench-scale (500 mL) to full-scale. Each simulant formulation was selected to be chemically representative of the waste streams anticipated to be fed to the LAWPS system, and used the current version of the LAWPS waste specification as a formulation basis. After simulantmore » development iterations, four simulants of varying sodium concentration (5.6M, 6.0M, 4.0M, and 8.0M) were prepared and characterized. The formulation basis, development testing, and final simulant recipes and characterization data for these four simulants are presented in this report.« less
Design, modeling and testing of a one-way energy harvesting backpack
NASA Astrophysics Data System (ADS)
Mi, Jia; Xu, Lin; Zhu, Ziheng; Liu, Mingyi; Zuo, Lei
2018-04-01
During trips and outdoor adventures, there are a lot of electric equipment and thus power supply for those devices is critical. At the same time, the burden on shoulders from heavy baggage is substantial. This paper presents a one-way energy harvesting backpack with ball-screw mechanism to generate electricity with high efficiency and reliability, while relieves the burden on shoulders. The one-way energy harvesting method only harvests negative work from human body and potentially reduce metabolic cost while carrying backpack. Simulations show that 4.5W of electrical energy can be obtained from human walking. Bench test results indicate this system can obtain an average power of 7.3 W with excitation of 2Hz and 25mm direct drive. Treadmill test to verify the performance of burden relieve on shoulders indicates this one-way design combing with elastic support strap can reduce the force on shoulders, which reduce fatigue in human.
Banaszek, Daniel; You, Daniel; Chang, Justues; Pickell, Michael; Hesse, Daniel; Hopman, Wilma M; Borschneck, Daniel; Bardana, Davide
2017-04-05
Work-hour restrictions as set forth by the Accreditation Council for Graduate Medical Education (ACGME) and other governing bodies have forced training programs to seek out new learning tools to accelerate acquisition of both medical skills and knowledge. As a result, competency-based training has become an important part of residency training. The purpose of this study was to directly compare arthroscopic skill acquisition in both high-fidelity and low-fidelity simulator models and to assess skill transfer from either modality to a cadaveric specimen, simulating intraoperative conditions. Forty surgical novices (pre-clerkship-level medical students) voluntarily participated in this trial. Baseline demographic data, as well as data on arthroscopic knowledge and skill, were collected prior to training. Subjects were randomized to 5-week independent training sessions on a high-fidelity virtual reality arthroscopic simulator or on a bench-top arthroscopic setup, or to an untrained control group. Post-training, subjects were asked to perform a diagnostic arthroscopy on both simulators and in a simulated intraoperative environment on a cadaveric knee. A more difficult surprise task was also incorporated to evaluate skill transfer. Subjects were evaluated using the Global Rating Scale (GRS), the 14-point arthroscopic checklist, and a timer to determine procedural efficiency (time per task). Secondary outcomes focused on objective measures of virtual reality simulator motion analysis. Trainees on both simulators demonstrated a significant improvement (p < 0.05) in arthroscopic skills compared with baseline scores and untrained controls, both in and ex vivo. The virtual reality simulation group consistently outperformed the bench-top model group in the diagnostic arthroscopy crossover tests and in the simulated cadaveric setup. Furthermore, the virtual reality group demonstrated superior skill transfer in the surprise skill transfer task. Both high-fidelity and low-fidelity simulation trainings were effective in arthroscopic skill acquisition. High-fidelity virtual reality simulation was superior to bench-top simulation in the acquisition of arthroscopic skills, both in the laboratory and in vivo. Further clinical investigation is needed to interpret the importance of these results.
The effects of combining elastic and free weight resistance on strength and power in athletes.
Anderson, Corey E; Sforzo, Gary A; Sigg, John A
2008-03-01
This study was undertaken to determine whether combined elastic and free weight resistance (CR) provides different strength and power adaptations than free weight resistance (FWR) training alone. Forty-four young (age 20 +/- 1 years), resistance-trained (4 +/- 2 years' experience) subjects were recruited from men's basketball and wrestling teams and women's basketball and hockey teams at Cornell University. Subjects were stratified according to team, then randomly assigned to the control (C; n = 21) or experimental group (E; n = 23). Before and after 7 weeks of resistance training, subjects were tested for lean body mass, 1 repetition maximum back squat and bench press, and peak and average power. Both C and E groups performed identical workouts except that E used CR (i.e., elastic resistance) for the back squat and bench press, whereas the C group used FWR alone. CR was performed using an elastic bungee cord attached to a standard barbell loaded with plates. Elastic tension was accounted for in an attempt to equalize the total work done by each group. Statistical analyses revealed significant (P < 0.05) between-group differences after training. Compared with C, improvement for E was nearly three times greater for back squat (16.47 +/- 5.67 vs. 6.84 +/- 4.42 kg increase), two times greater for bench press (6.68 +/- 3.41 vs. 3.34 +/- 2.67 kg increase), and nearly three times greater for average power (68.55 +/- 84.35 vs. 23.66 +/- 40.56 watt increase). Training with CR may be better than FWR alone for developing lower and upper body strength, and lower body power in resistance-trained individuals. Long-term effects are unclear, but CR training makes a meaningful contribution in the short term to performance adaptations of experienced athletes.
NASA Astrophysics Data System (ADS)
Hajnayeb, Ali; Nikpour, Masood; Moradi, Shapour; Rossi, Gianluca
2018-02-01
The blade tip-timing (BTT) measurement technique is at present the most promising technique for monitoring the blades of axial turbines and aircraft engines in operating conditions. It is generally used as an alternative to strain gauges in turbine testing. By conducting a comparison with the standard methods such as those based on strain gauges, one determines that the technique is not intrusive and does not require a complicated installation process. Despite its superiority to other methods, the experimental performance analysis of a new BTT method needs a test stand that includes a reference measurement system (e.g. strain gauges equipped with telemetry or other complex optical measurement systems, like rotating laser Doppler vibrometers). In this article, a new reliable, low-cost BTT test setup is proposed for simulating and analyzing blade vibrations based on kinematic inversion. In the proposed test bench, instead of the blades vibrating, it is the BTT sensor that vibrates. The vibration of the sensor is generated by a shaker and can therefore be easily controlled in terms of frequency, amplitude and waveform shape. The amplitude of vibration excitation is measured by a simple accelerometer. After introducing the components of the simulator, the proposed test bench is used in practice to simulate both synchronous and asynchronous vibration scenarios. Then two BTT methods are used to evaluate the quality of the acquired data. The results demonstrate that the proposed setup is able to generate simulated pulse sequences which are almost the same as those generated by the conventional BTT systems installed around a bladed disk. Moreover, the test setup enables its users to evaluate BTT methods by using a limited number of sensors. This significantly reduces the total costs of the experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pradhan, V.R.; Lee, L.K.; Stalzer, R.H.
1995-12-31
The development of Catalytic Multi-Stage Liquefaction (CMSL) at HTI has focused on both bituminous and sub-bituminous coals using laboratory, bench and PDU scale operations. The crude oil equivalent cost of liquid fuels from coal has been curtailed to about $30 per barrel, thus achieving over 30% reduction in the price that was evaluated for the liquefaction technologies demonstrated in the late seventies and early eighties. Contrary to the common belief, the new generation of catalytic multistage coal liquefaction process is environmentally very benign and can produce clean, premium distillates with a very low (<10ppm) heteroatoms content. The HTI Staff hasmore » been involved over the years in process development and has made significant improvements in the CMSL processing of coals. A 24 month program (extended to September 30, 1995) to study novel concepts, using a continuous bench scale Catalytic Multi-Stage unit (30kg coal/day), has been initiated since December, 1992. This program consists of ten bench-scale operations supported by Laboratory Studies, Modelling, Process Simulation and Economic Assessments. The Catalytic Multi-Stage Liquefaction is a continuation of the second generation yields using a low/high temperature approach. This paper covers work performed between October 1994- August 1995, especially results obtained from the microautoclave support activities and the bench-scale operations for runs CMSL-08 and CMSL-09, during which, coal and the plastic components for municipal solid wastes (MSW) such as high density polyethylene (HDPE)m, polypropylene (PP), polystyrene (PS), and polythylene terphthlate (PET) were coprocessed.« less
Evaluation of seismic testing for quality assurance of lime-stabilized soil.
DOT National Transportation Integrated Search
2013-08-01
This study sought to determine the technical feasibility of using seismic techniques to measure the : laboratory and field seismic modulus of lime-stabilized soils (LSS), and to compare/correlate test results : from bench-top (free-free resonance) se...
Evaluation of mechanical and corrosion properties of MMFX reinforcing steel for concrete
DOT National Transportation Integrated Search
2004-01-01
The corrosion performance of MMFX and conventional reinforcing steels is compared based on macrocell and bench-scale tests. The conventional steel includes epoxy-coated and uncoated bars. Macrocell tests are conducted on bare bars and bars symmetrica...
ComprehensiveBench: a Benchmark for the Extensive Evaluation of Global Scheduling Algorithms
NASA Astrophysics Data System (ADS)
Pilla, Laércio L.; Bozzetti, Tiago C.; Castro, Márcio; Navaux, Philippe O. A.; Méhaut, Jean-François
2015-10-01
Parallel applications that present tasks with imbalanced loads or complex communication behavior usually do not exploit the underlying resources of parallel platforms to their full potential. In order to mitigate this issue, global scheduling algorithms are employed. As finding the optimal task distribution is an NP-Hard problem, identifying the most suitable algorithm for a specific scenario and comparing algorithms are not trivial tasks. In this context, this paper presents ComprehensiveBench, a benchmark for global scheduling algorithms that enables the variation of a vast range of parameters that affect performance. ComprehensiveBench can be used to assist in the development and evaluation of new scheduling algorithms, to help choose a specific algorithm for an arbitrary application, to emulate other applications, and to enable statistical tests. We illustrate its use in this paper with an evaluation of Charm++ periodic load balancers that stresses their characteristics.
Translational Medicine is developing in China: a new venue for collaboration.
Wang, Xiangdong; Wang, Ena; Marincola, Francesco M
2011-01-04
Translational Medicine is an emerging area comprising multidisciplinary Research from basic sciences to medical applications well summarized by the Bench-to-Beside concept; this entails close collaboration between clinicians and basic scientists across institutes. We further clarified that Translational Medicine should be regarded as a two-way road: Bench-to-Bedside and Bedside-to-Bench, to complement testing of novel therapeutic strategies in humans with feedback understanding of how they respond to them. It is, therefore, critical and important to define and promote Translational Medicine among clinicians, basic Researchers, biotechnologists, politicians, ethicists, sociologists, investors and coordinate these efforts among different Countries, fostering aspects germane only to this type of Research such as, as recently discussed, biotechnology entrepreneurship. Translational Medicine as an inter-disciplinary science is developing rapidly and widely and, in this article, we will place a special emphasis on China.
Latest developments at the ALBA magnetic measurements laboratory
NASA Astrophysics Data System (ADS)
Marcos, J.; Massana, V.; García, L.; Campmany, J.
2018-02-01
ALBA is a third-generation synchrotron light source that has been in operation since 2012 near Barcelona. A magnetic measurements laboratory has been associated with the facility since its very early stages and has been active for the last 20 years. In the first part of this work, the different instruments available at the laboratory are described, and a brief overview of the measurement campaigns carried out during its 20 years of history is presented. In the second part, a more detailed description of the approach to Hall probe measurements adopted at ALBA is offered, with an explanation of the methods and ancillary equipment that have been developed along the years in order to improve the accuracy of the system. In the third part, a new concept of Hall probe bench devoted to the measurement of closed structures is presented. The in-house design and building of a prototype for such a bench is described, together with its mechanical and magnetic characterization. As a conclusion, the first results obtained with this bench are discussed.
Behavior and structure of metal vapor arc plasma between molten electrodes
NASA Astrophysics Data System (ADS)
Zanner, F. J.; Williamson, R. L.; Hareland, W. A.; Bertram, L. A.
A metal vapor arc is utilized in the industrially important vacuum arc remelting (VAR) process to produce materials by melting and resolidification which have improved structure and chemical homogeneity. Homogeneity is dependent on achieving quasi-steady conditions in the plasma because of its thermal and MHD coupling with the molten pool atop the ingot. Optimal operating conditions of low pressure (approx. = 0.01 torr) and short electrode gap (less than 15 mm) produce a diffuse arc and cathode spot behavior similar to that observed for the vacuum breaker arc. Under these conditions the arc provides a quasi-steady heat source that is considered to be the bench mark arc of the VAR process. Previous work has shown that deviation from the bench mark arc behavior can occur under production conditions, and is caused by electrode irregularities and liberation of gases such as CO from the molten pool. This study is an effort to characterize these behavioral deviations and discover operational conditions which stabilize the bench mark arc.
Effectiveness evaluation of existing noise controls in a deep shaft underground mine.
Lutz, Eric A; Reed, Rustin J; Turner, Dylan; Littau, Sally R; Lee, Vivien; Hu, Chengcheng
2015-01-01
Noise exposures and hearing loss in the mining industry continue to be a major problem, despite advances in noise control technologies. This study evaluated the effectiveness of engineering, administrative, and personal noise controls using both traditional and in-ear dosimetry by job task, work shift, and five types of earplug. The noise exposures of 22 miners performing deep shaft-sinking tasks were evaluated during 56 rotating shifts in an underground mine. Miners were earplug-insertion trained, earplug fit-tested, and monitored utilizing traditional and in-ear dosimetry. The mean TWA8 noise exposure via traditional dosimetry was 90.1 ± 8.2 dBA, while the mean in-ear TWA8 was 79.6 ± 13.8 dBA. The latter was significantly lower (p < 0.05) than the Mine Safety and Health Administration (MSHA) personal exposure limit (PEL) of 90 dBA. Dosimetry mean TWA8 noise exposures for bench blowing (103.5 ± 0.9 dBA), jumbo drill operation (103.0 ± 0.8 dBA), and mucking tasks (99.6 ± 4.7 dBA) were significantly higher (p < 0.05) than other tasks. For bench blowing, cable pulling, grinding, and jumbo drill operation tasks, the mean in-ear TWA8 was greater than 85 dBA. Those working swing shift had a significantly higher (p < 0.001) mean TWA8 noise exposure (95.4 ± 7.3 dBA) than those working day shift. For percent difference between traditional vs. in-ear dosimetry, there was no significant difference among types of earplug used. Reflective of occupational hearing loss rate trends across the mining industry, this study found that, despite existing engineering and administrative controls, noise exposure levels exceeded regulatory limits, while the addition of personal hearing protection limited excessive exposures.
Respiratory muscle adaptations: a comparison between bodybuilders and endurance athletes.
Hackett, D A; Johnson, N; Chow, C
2013-04-01
The purpose of this study was to compare the respiratory muscle and lung function measures of bodybuilders (BB) and endurance athletes (EA). Forty-two male subjects (22 BB and 20 EA) aged 20-35 years underwent respiratory muscle strength measurements (MIP and MEP), lung function testing (FEV1, FVC, FEV1/FVC%, IC, ERV, FRC, RV, and TLC), hydrostatic weighing and VO2max testing. One-repetition maximum (1RM) for bench press, squat and deadlift was performed by BB. BB had significantly greater MIP and MEP compared to EA by 43% and 53% respectively (P<0.01). Moderate correlation was found for MEP and 1RM bench press (P<0.01), and weak correlations found for the squat and deadlift (P<0.01). Fat-free mass was significantly greater for BB compared with EA (P<0.01), while VO2max was significantly greater for EA compared with BB (P<0.01). No differences in lung function indices were observed between groups. When compared to EA, BB exhibited significantly greater respiratory muscle strength. The maximal load lifted for bench press predicted expiratory muscle strength gain. Lung function measures did not differ between the groups.
Reliability assessment of ballistic jump squats and bench throws.
Alemany, Joseph A; Pandorf, Clay E; Montain, Scott J; Castellani, John W; Tuckow, Alexander P; Nindl, Bradley C
2005-02-01
The purpose of this investigation was to determine the test-retest reliability and coefficient of variation of 2 novel physical performance tests. Ten healthy men (22.0 +/- 3.0 years, 87.0 +/- 8.0 kg, 20.0 +/- 5.0% body fat) performed 30 continuous and dynamic jump squats (JS) and bench throws (BT) on 4 separate occasions. The movements were performed under loaded conditions utilizing 30% of subject's predetermined 1 repetition maximum in the back squat and bench press. Mean power (MP; W), peak power (PP; W), mean velocity (MV; m.s(-1)), peak velocity (PV; m.s(-1)), and total work (TW; J) were assessed using a ballistic measurement system (Innervations Inc., Muncie, IN). Data were analyzed using repeated measures analysis of variance with Duncan's post hoc test when mean differences were p < or = 0.05. Intraclass correlation coefficient (ICC) and within-subject coefficient of variation (CV%) were also calculated. All values are presented as mean +/- SE. BT variables were statistically similar across the 4 sessions: MP (350.0 +/- 13.9 W), PP (431.4 +/- 18.5 W) MV (1.6 +/- 0.03 m.s(-1)), PV (2.0 +/- 0.03 m.s(-1)), and TW (199.1 +/- 7.2 J). For JS, session 3 PP (1,669.8 +/- 111.2 W) was significantly greater vs. sessions 1, 2, and 4 (1,601.2 +/- 58.4 W). Session 4 MP (1,403.2 +/- 88.6 W) and MV (1.9 +/- 0.1 m.s(-1)) for JS were significantly lower during sessions 1, 2, and 3 (MP: 1,479.4.5 +/- 44.8 W, MV: 2.0 +/- 0.05 m.s(-1)). TW (834.7 +/- 24.3 J) and PV (2.2 +/- 0.04 m.s(-1)) were statistically similar during all sessions for JS. The CVs ranged from 3.0 to 7.6% for the BT and 3.2 to 5.7% for the JS. ICCs for MP, PP, MV, PV, and TW were 0.92, 0.95, 0.94, 0.91, and 0.95, respectively, during BT. ICCs during JS for MP, PP, MV, PV, and TW were 0.96, 0.98, 0.94, 0.94, and 0.89, respectively. The results of the current study support the use of a 30 continuous and dynamic BT protocol as a reliable upper-body physical performance test, which can be administered with minimal practice. Slightly greater variability for JS was observed, although the test had high reliability.
NASA Astrophysics Data System (ADS)
Leroux, B.; Cali, J.; Verdun, J.; Morel, L.; He, H.
2017-08-01
Airborne LiDAR systems require the use of Direct Georeferencing (DG) in order to compute the coordinates of the surveyed point in the mapping frame. An UAV platform does not derogate to this need, but its payload has to be lighter than this installed onboard so the manufacturer needs to find an alternative to heavy sensors and navigation systems. For the georeferencing of these data, a possible solution could be to replace the Inertial Measurement Unit (IMU) by a camera and record the optical flow. The different frames would then be processed thanks to photogrammetry so as to extract the External Orientation Parameters (EOP) and, therefore, the path of the camera. The major advantages of this method called Visual Odometry (VO) is low cost, no drifts IMU-induced, option for the use of Ground Control Points (GCPs) such as on airborne photogrammetry surveys. In this paper we shall present a test bench designed to assess the reliability and accuracy of the attitude estimated from VO outputs. The test bench consists of a trolley which embeds a GNSS receiver, an IMU sensor and a camera. The LiDAR is replaced by a tacheometer in order to survey the control points already known. We have also developped a methodology applied to this test bench for the calibration of the external parameters and the computation of the surveyed point coordinates. Several tests have revealed a difference about 2-3 centimeters between the control point coordinates measured and those already known.
Postactivation potentiation: effect of various recovery intervals on bench press power performance.
Ferreira, Sandra Lívia de Assis; Panissa, Valéria Leme Gonçalves; Miarka, Bianca; Franchini, Emerson
2012-03-01
Postactivation potentiation (PAP) is a strategy used to improve performance in power activities. The aim of this study was to determine if power during bench press exercise was increased when preceded by 1 repetition maximum (1RM) in the same exercise and to determine which time interval could optimize PAP response. For this, 11 healthy male subjects (age, 25 ± 4 years; height, 178 ± 6 cm; body mass, 74 ± 8 kg; bench press 1RM, 76 ± 19 kg) underwent 6 sessions. Two control sessions were conducted to determine both bench press 1RM and power (6 repetitions at 50% 1RM). The 4 experimental sessions were composed of a 1RM exercise followed by power sets with different recovery intervals (1, 3, 5, and 7 minutes), performed on different days, and determined randomly. Power values were measured via Peak Power equipment (Cefise, Nova Odessa, São Paulo, Brazil). The conditions were compared using an analysis of variance with repeated measures, followed by a Tukey test. The significance level was set at p < 0.05. There was a significant increase in PAP in concentric contractions after 7 minutes of recovery compared with the control and 1-minute recovery conditions (p < 0.05). Our results indicated that 7 minutes of recovery has generated an increase in PAP in bench press and that such a strategy could be applied as an interesting alternative to enhance the performance in tasks aimed at increasing upper-body power performance.
NASA Astrophysics Data System (ADS)
Courteau, Pascal; Poupinet, Anne; Kroedel, Mathias; Sarri, Giuseppe
2017-11-01
Global astrometry, very demanding in term of stability, requires extremely stable material for optical bench. CeSiC developed by ECM and Alcatel Alenia Space for mirrors and high stability structures, offers the best compromise in term of structural strength, stability and very high lightweight capability, with characteristics leading to be insensitive to thermo-elastic at cryogenic T°. The HSOB GAIA study realised by Alcatel Alenia Space under ESA contract aimed to design, develop and test a full scale representative High Stability Optical Bench in CeSiC. The bench has been equipped with SAGEIS-CSO laser metrology system MOUSE1, Michelson interferometer composed of integrated optics with a nm resolution. The HSOB bench has been submitted to an homogeneous T° step under vacuum to characterise the homothetic behaviour of its two arms. The quite negligible inter-arms differential measured with a nm range reproducibility, demonstrates that a complete 3D structure in CeSiC has the same CTE homogeneity as characterisation samples, fully in line with the GAIA need (1pm at 120K). This participates to the demonstration that CeSiC properties at cryogenic T° is fully appropriate to the manufacturing of complex highly stable optical structures. This successful study confirms ECM and Alcatel Alenia Space ability to define and manufacture monolithic lightweight highly stable optical structures, based on inner cells triangular design made only possible by the unique CeSiC manufacturing process.
Bench press and push-up at comparable levels of muscle activity results in similar strength gains.
Calatayud, Joaquin; Borreani, Sebastien; Colado, Juan C; Martin, Fernando; Tella, Victor; Andersen, Lars L
2015-01-01
Electromyography (EMG) exercise evaluation is commonly used to measure the intensity of muscle contraction. Although researchers assume that biomechanically comparable resistance exercises with similar high EMG levels will produce similar strength gains over the long term, no studies have actually corroborated this hypothesis. This study evaluated EMG levels during 6 repetition maximum (6RM) bench press and push-up, and subsequently performed a 5-week training period where subjects were randomly divided into 3 groups (i.e., 6RM bench press group, 6RM elastic band push-up group, or control group) to evaluate muscle strength gains. Thirty university students with advanced resistance training experience participated in the 2-part study. During the training period, exercises were performed using the same loads and variables that were used during the EMG data collection. At baseline, EMG amplitude showed no significant difference between 6RM bench press and band push-up. Significant differences among the groups were found for percent change (Δ) between pretest and posttest for 6RM (p = 0.017) and for 1 repetition maximum (1RM) (p < 0.001). Six repetition maximum bench press group and 6RM elastic band push-up group improved their 1RM and 6RM (Δ ranging from 13.65 to 22.21) tests significantly with similar gains, whereas control group remains unchanged. Thus, when the EMG values are comparable and the same conditions are reproduced, the aforementioned exercises can provide similar muscle strength gains.
Phase III Advanced Anodes and Cathodes Utilized in Energy Efficient Aluminum Production Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.A. Christini; R.K. Dawless; S.P. Ray
2001-11-05
During Phase I of the present program, Alcoa developed a commercial cell concept that has been estimated to save 30% of the energy required for aluminum smelting. Phase ii involved the construction of a pilot facility and operation of two pilots. Phase iii of the Advanced Anodes and Cathodes Program was aimed at bench experiments to permit the resolution of certain questions to be followed by three pilot cells. All of the milestones related to materials, in particular metal purity, were attained with distinct improvements over work in previous phases of the program. NiO additions to the ceramic phase andmore » Ag additions to the Cu metal phase of the cermet improved corrosion resistance sufficiently that the bench scale pencil anodes met the purity milestones. Some excellent metal purity results have been obtained with anodes of the following composition: Further improvements in anode material composition appear to be dependent on a better understanding of oxide solubilities in molten cryolite. For that reason, work was commissioned with an outside consultant to model the MeO - cryolite systems. That work has led to a better understanding of which oxides can be used to substitute into the NiO-Fe2O3 ceramic phase to stabilize the ferrites and reduce their solubility in molten cryolite. An extensive number of vertical plate bench electrolysis cells were run to try to find conditions where high current efficiencies could be attained. TiB2-G plates were very inconsistent and led to poor wetting and drainage. Pure TiB2 did produce good current efficiencies at small overlaps (shadowing) between the anodes and cathodes. This bench work with vertical plate anodes and cathodes reinforced the importance of good cathode wetting to attain high current efficiencies. Because of those conclusions, new wetting work was commissioned and became a major component of the research during the third year of Phase III. While significant progress was made in several areas, much work needs to be done. The anode composition needs further improvements to attain commercial purity targets. At the present corrosion rate, the vertical plate anodes will wear too rapidly leading to a rapidly increasing anode-cathode gap and thermal instabilities in the cell. Cathode wetting as a function of both cathode plate composition and bath composition needs to be better understood to ensure that complete drainage of the molten aluminum off the plates occurs. Metal buildup appears to lead to back reaction and low current efficiencies.« less
STOP Analysis and Optimization of a Very-Low-Distortion Space Instrument: HST WFC3 Case Study
NASA Technical Reports Server (NTRS)
Kunt, Cengiz; Broduer, Steve (Technical Monitor)
2001-01-01
New generation optical instruments with very demanding stability requirements are being proposed and developed for space applications. STOP (Structural-Thermal-Optical Performance) analysis and optimization is crucial in meeting the very tight distortion budgets of these instruments. This presentation outlines STOP analysis and optimization approach in the context of WFC3 (Wide-Field Camera 3), which is a radial instrument designed to replace the Wide-Field Planetary Camera 2 (WFPC2) of the Hubble Space Telescope (HST). WFC3 houses two separate channels, UVIS and IR, and will have greater throughput and sensitivity than WFPC2. WFC3 line-of-sight alignment budget for the UVIS and IR channels are as small as 10 and 20 milli-arcsec, respectively. Its optical bench is the most critical subsystem effecting the optical stability of WFC3 hence our effort concentrates on the design and analysis of the bench and its interfaces. Structural analysis has accompanied the mechanical design of the bench since the initial concept study. A high fidelity structural Finite Element Model (FEM) of the bench has been developed and used for minimizing its thermally induced distortions as well as sizing it to meet the stiffness and strength requirements of a Shuttle launch. The bench is a composite honeycomb panel box structure with a very low planar Coefficient of Thermal Expansion (CTE) of approximately 0.1 ppm/C. Optic components are mounted to super-INVAR inserts bonded into the panels. The bench is kinematically supported on three HST latches via interface struts, which are tailored to exhibit negative CTE to cancel out the thermal motions of the latches. The interface struts also incorporate flexure elements to minimize the mechanical distortions coming into the bench from its enclosure. Bench FEM is coupled with the enclosure FEM to quantify these effects. Short term or on-orbit STOP analysis includes distortion due to the temperature variations of the bench, the struts, and the enclosure. Long term or ground-to-orbit STOP analysis includes distortional effects of gravity release, desorption, and assembly in addition to the ground-to-orbit temperature variations. A rigorous testing program has been implemented for verifying the material properties and the analysis predictions. STOP analysis results demonstrate that both the short-term and the long-term alignment budgets will be met. Presentation will cover design and analysis details that are critical to a successful implementation of the STOP analysis and optimization process.
NASA Astrophysics Data System (ADS)
Isleif, Katharina-Sophie; Bischof, Lea; Ast, Stefan; Penkert, Daniel; Schwarze, Thomas S.; Fernández Barranco, Germán; Zwetz, Max; Veith, Sonja; Hennig, Jan-Simon; Tröbs, Michael; Reiche, Jens; Gerberding, Oliver; Danzmann, Karsten; Heinzel, Gerhard
2018-04-01
LISA is a proposed space-based laser interferometer detecting gravitational waves by measuring distances between free-floating test masses housed in three satellites in a triangular constellation with laser links in-between. Each satellite contains two optical benches that are articulated by moving optical subassemblies for compensating the breathing angle in the constellation. The phase reference distribution system, also known as backlink, forms an optical bi-directional path between the intra-satellite benches. In this work we discuss phase reference implementations with a target non-reciprocity of at most 2π μrad \\sqrtHz-1 , equivalent to 1 pm \\sqrtHz-1 for a wavelength of 1064 nm in the frequency band from 0.1 mHz to 1 Hz. One phase reference uses a steered free beam connection, the other one a fiber together with additional laser frequencies. The noise characteristics of these implementations will be compared in a single interferometric set-up with a previously successfully tested direct fiber connection. We show the design of this interferometer created by optical simulations including ghost beam analysis, component alignment and noise estimation. First experimental results of a free beam laser link between two optical set-ups that are co-rotating by ±1° are presented. This experiment demonstrates sufficient thermal stability during rotation of less than 10‑4 K \\sqrtHz-1 at 1 mHz and operation of the free beam steering mirror control over more than 1 week.
Cionni, Robert J; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-08-01
To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery.
Coal technology program progress report, February 1976
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Final testing of the 20-atm bench-scale system is underway in preparation for experiments with hydrogen. Laboratory-scale testing of a number of inexpensive pure compounds to improve the settling rate of solids in Solvent Refined Coal (SRC) unfiltered oil (UFO), bench-scale testing of the effect of the Tretolite additive on settling, and characterization tests on a new sample of UFO from the PAMCO-SRC process are reported. Experimental engineering support of an in situ gasification process include low-temperature pyrolyses at exceptionally low heating rates (0.3/sup 0/C/min). Highly pyrophoric chars were consistently produced. Aqueous by-products from coal conversion technologies and oil shale retortingmore » have been analyzed directly to determine major organic components. A report is being prepared discussing various aspects of the engineering evaluations of nuclear process heat for coal. A bench-scale test program on thermochemical water splitting for hydrogen production is under consideration. In the coal-fueled MIUS program, preparations for procurement of tubing for the matrix in the fluidized-bed furnace and for fabrication of the furnace continued. Analyses of the AiResearch gas turbine and recuperator under coal-fueled MIUS operating conditions are near completion. Process flow diagrams and heat and material balances were completed for most of the units in the synthoil process. Overall utilities requirements were calculated and the coal preparation flowsheets were finalized. For hydrocarbonization, the flowsheet was revised to include additional coal data. Flowsheets were finalized for the acid gas separation and recycle, and the oil-solids separation. (LTN)« less
Association Between Neuromuscular Tests and Kumite Performance on The Brazilian Karate National Team
Roschel, Hamilton; Batista, Mauro; Monteiro, Rodrigo; Bertuzzi, Romulo C.; Barroso, Renato; Loturco, Irineu; Ugrinowitsch, Carlos; Tricoli, Valmor; Franchini, Emerson
2009-01-01
The aim of this study was to verify the relationship of strength and power with performance on an international level karate team during official kumite simulations. Fourteen male black belt karate athletes were submitted to anthropometric data collection and then performed the following tests on two different days: vertical jump test, bench press and squat maximum dynamic strength (1RM) tests. We also tested power production for both exercises at 30 and 60%1RM and performed a kumite match simulation. Blood samples were obtained at rest and immediately after the kumite matches to measure blood lactate concentration. Karate players were separated by performance (winners vs. defeated) on the kumite matches. We found no significant differences between winners and defeated for strength, vertical jump height, anthropometric data and blood lactate concentration. Interestingly, winners were more powerful in the bench press and squat exercises at 30% 1RM. Maximum strength was correlated with absolute (30% 1RM r = 0.92; 60% 1RM r = 0.63) and relative power (30% 1RM r = 0.74; 60% 1RM r = 0.11, p > 0.05) for the bench press exercise. We concluded that international level karate players’ kumite match performance are influenced by higher levels of upper and lower limbs power production. Key Points Muscle power at low workloads seems to be a reasonable predictor of karate performance. There are differences in neuromuscular characteristics between winners and defeated karate players among an international level karate team. Karate players rely more on muscle power, rather than on muscle strength. PMID:24474882
Loturco, Irineu; Kobal, Ronaldo; Moraes, José E; Kitamura, Katia; Cal Abad, César C; Pereira, Lucas A; Nakamura, Fábio Y
2017-04-01
Loturco, I, Kobal, R, Moraes, JE, Kitamura, K, Cal Abad, CC, Pereira, LA, and Nakamura, FY. Predicting the maximum dynamic strength in bench press: the high precision of the bar velocity approach. J Strength Cond Res 31(4): 1127-1131, 2017-The aim of this study was to determine the force-velocity relationship and test the possibility of determining the 1 repetition maximum (1RM) in "free weight" and Smith machine bench presses. Thirty-six male top-level athletes from 3 different sports were submitted to a standardized 1RM bench press assessment (free weight or Smith machine, in randomized order), following standard procedures encompassing lifts performed at 40-100% of 1RM. The mean propulsive velocity (MPV) was measured in all attempts. A linear regression was performed to establish the relationships between bar velocities and 1RM percentages. The actual and predicted 1RM for each exercise were compared using a paired t-test. Although the Smith machine 1RM was higher (10% difference) than the free weight 1RM, in both cases the actual and predicted values did not differ. In addition, the linear relationship between MPV and percentage of 1RM (coefficient of determination ≥95%) allow determination of training intensity based on the bar velocity. The linear relationships between the MPVs and the relative percentages of 1RM throughout the entire range of loads enable coaches to use the MPV to accurately monitor their athletes on a daily basis and accurately determine their actual 1RM without the need to perform standard maximum dynamic strength assessments.
Design guidelines for high dimensional stability of CFRP optical bench
NASA Astrophysics Data System (ADS)
Desnoyers, Nichola; Boucher, Marc-André; Goyette, Philippe
2013-09-01
In carbon fiber reinforced plastic (CFRP) optomechanical structures, particularly when embodying reflective optics, angular stability is critical. Angular stability or warping stability is greatly affected by moisture absorption and thermal gradients. Unfortunately, it is impossible to achieve the perfect laminate and there will always be manufacturing errors in trying to reach a quasi-iso laminate. Some errors, such as those related to the angular position of each ply and the facesheet parallelism (for a bench) can be easily monitored in order to control the stability more adequately. This paper presents warping experiments and finite-element analyses (FEA) obtained from typical optomechanical sandwich structures. Experiments were done using a thermal vacuum chamber to cycle the structures from -40°C to 50°C. Moisture desorption tests were also performed for a number of specific configurations. The selected composite material for the study is the unidirectional prepreg from Tencate M55J/TC410. M55J is a high modulus fiber and TC410 is a new-generation cyanate ester designed for dimensionally stable optical benches. In the studied cases, the main contributors were found to be: the ply angular errors, laminate in-plane parallelism (between 0° ply direction of both facesheets), fiber volume fraction tolerance and joints. Final results show that some tested configurations demonstrated good warping stability. FEA and measurements are in good agreement despite the fact that some defects or fabrication errors remain unpredictable. Design guidelines to maximize the warping stability by taking into account the main dimensional stability contributors, the bench geometry and the optical mount interface are then proposed.
Calibrating/testing meters in hot water test bench VM7
NASA Astrophysics Data System (ADS)
Kling, E.; Stolt, K.; Lau, P.; Mattiasson, K.
A Hot Water Test Bench, VM7, has been developed and constructed for the calibration and testing of volume and flowmeters, in a project at the National Volume Measurement Laboratory at the Swedish National Testing and Research Institute. The intended area of use includes use as a reference at audit measurements, e.g. for accredited laboratories, calibration of meters for the industry and for the testing of hot water meters. The objective of the project, which was initiated in 1989, was to design equipment with stable flow and with a minimal temperature drop even at very low flow rates. The principle of the design is a closed system with two pressure tanks at different pressures. The water is led from the high pressure tank through the test object and the volume standard, in the form of master meters or a piston prover alternatively, to the low pressure tank. Calibrations/tests are made comparing the indication of the test object to that of master meters covering the current flow rate. These are, in the same test cycle, calibrated to the piston prover. Alternatively, the test object can be calibrated directly to the piston prover.
Damage detection in rotating machinery by means of entropy-based parameters
NASA Astrophysics Data System (ADS)
Tocarciuc, Alexandru; Bereteu, Liviu; ǎgǎnescu, Gheorghe Eugen, Dr
2014-11-01
The paper is proposing two new entropy-based parameters, namely Renyi Entropy Index (REI) and Sharma-Mittal Entropy Index (SMEI), for detecting the presence of failures (or damages) in rotating machinery, namely: belt structural damage, belt wheels misalignment, failure of the fixing bolt of the machine to its baseplate and eccentricities (i.e.: due to detaching a small piece of material or bad mounting of the rotating components of the machine). The algorithms to obtain the proposed entropy-based parameters are described and test data is used in order to assess their sensitivity. A vibration test bench is used for measuring the levels of vibration while artificially inducing damage. The deviation of the two entropy-based parameters is compared in two states of the vibration test bench: not damaged and damaged. At the end of the study, their sensitivity is compared to Shannon Entropic Index.
Formulation and evaluation of C-Ether fluids as lubricants useful to 260 C. [air breathing engines
NASA Technical Reports Server (NTRS)
Clark, F. S.; Miller, D. R.
1980-01-01
Three base stocks were evaluated in bench and bearing tests to determine their suitability for use at bulk oil temperatures (BOT) from -40 C to +260 C. A polyol ester gave good bearing tests at a bulk temperature of 218 C, but only a partially successful run at 274 C. These results bracket the fluid's maximum operating temperature between these values. An extensive screening program selected lubrication additives for a C-ether (modified polyphenyl ether) base stock. One formulation lubricated a bearing for 111 hours at 274 C (BOT), but this fluid gave many deposit related problems. Other C-ether blends produced cage wear or fatigue failures. Studies of a third fluid, a C-ether/disiloxane blend, consisted of bench oxidation and lubrication tests. These showed that some additives react differently in the blend than in pure C-ethers.
NASA Astrophysics Data System (ADS)
Barrette, Jeremie
The current project is inscribed in the research axis on bioactive coatings of Dr. Sophie Lerouge's
ERIC Educational Resources Information Center
Shriver, Edgar L.; And Others
This document furnishes a complete copy of the Test Subject's Instructions and the Test Administrator's Handbook for a battery of criterion referenced Job Task Performance Tests (JTPT) for electronic maintenance. General information is provided on soldering, Radar Set AN/APN-147(v), Radar Set Special Equipment, Radar Set Bench Test Set-Up, and…
40 CFR Appendix Viii to Part 86 - Aging Bench Equipment and Procedures
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Aging Bench Equipment and Procedures.... 86, App. VIII Appendix VIII to Part 86—Aging Bench Equipment and Procedures This appendix provides specifications for standard aging bench equipment and aging procedures which may be used to conduct bench aging...
40 CFR Appendix Viii to Part 86 - Aging Bench Equipment and Procedures
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Aging Bench Equipment and Procedures.... VIII Appendix VIII to Part 86—Aging Bench Equipment and Procedures This appendix provides specifications for standard aging bench equipment and aging procedures which may be used to conduct bench aging...
40 CFR Appendix Viii to Part 86 - Aging Bench Equipment and Procedures
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Aging Bench Equipment and Procedures.... 86, App. VIII Appendix VIII to Part 86—Aging Bench Equipment and Procedures This appendix provides specifications for standard aging bench equipment and aging procedures which may be used to conduct bench aging...
42 CFR 84.126 - Canister bench tests; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks... canisters designated as providing respiratory protection against gases, ammonia, organic vapors, carbon...
42 CFR 84.126 - Canister bench tests; minimum requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks... canisters designated as providing respiratory protection against gases, ammonia, organic vapors, carbon...
42 CFR 84.126 - Canister bench tests; minimum requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks... canisters designated as providing respiratory protection against gases, ammonia, organic vapors, carbon...
42 CFR 84.126 - Canister bench tests; minimum requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks... canisters designated as providing respiratory protection against gases, ammonia, organic vapors, carbon...
42 CFR 84.126 - Canister bench tests; minimum requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks... canisters designated as providing respiratory protection against gases, ammonia, organic vapors, carbon...
Fixed Equipment in the Energy Systems Integration Facility | Energy Systems
dynamic simulation of future energy systems. Photo of a robot used to test hydrogen coupling hardware. At test chambers (rated up to 60°C) for testing HVAC systems under simulated loading conditions Two bench performance Test stand for measuring performance of receiver tubes for concentrating solar power applications
Relationship between isometric and dynamic strength in recreationally trained men.
McGuigan, Michael R; Newton, Michael J; Winchester, Jason B; Nelson, Arnold G
2010-09-01
The purpose of this investigation was to examine the relationships between measures of maximal isometric force (peak force [PF]), rate of force development (RFD), vertical jump performance (VJ) and 1-repetition maximum (1RM) strength in recreationally trained men. The subjects in this study were 26 men ([mean +/- SD]: age 22 +/- 1 years; height 175 +/- 7 cm; mass 90 +/- 10 kg). They were tested for PF using the isometric midthigh pull exercise. The 1RM for the squat and bench press exercise were determined as a measure of dynamic strength. Explosive strength was measured as RFD from the isometric force-time curve. Correlations between the variables were calculated using Pearson product moment correlation coefficient. There was a nearly perfect correlation between measures of PF and 1RM squat (r = 0.97, p < 0.05) and 1RM bench press (r = 0.99, p < 0.05). The correlations were very strong between VJ and PF (r = 0.72, p < 0.05) and 1RM bench press (r = 0.70, p < 0.05). There were also strong correlations between VJ and 1RM squat (r = 0.69, p < 0.05). There were no significant correlations with RFD. The results showed that isometric maximum strength determined during the isometric midthigh pull test correlated well with 1RM and VJ testing. However, RFD measured during the same test did not appear to correlate as well with other measures. The isometric midthigh pull provides an efficient method for assessing strength in recreationally trained individuals. Practitioners wishing to obtain performance data related to maximum strength may wish to consider isometric testing as a less time intensive method of testing.
Bench Work and Support Operations, Machine Shop Work--Intermediate: 9555.02.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
The course outline has been prepared as a guide to assist the instructor to plan systematically and to present meaningful lessons programmed to meet the necessary training needed by the machine shop student who has completed an introductory course in machine tool technology. The five blocks of instruction contained in this outline are designed to…
Italian High-speed Airplane Engines
NASA Technical Reports Server (NTRS)
Bona, C F
1940-01-01
This paper presents an account of Italian high-speed engine designs. The tests were performed on the Fiat AS6 engine, and all components of that engine are discussed from cylinders to superchargers as well as the test set-up. The results of the bench tests are given along with the performance of the engines in various races.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salmon, Sonja; House, Alan; Liu, Kun
An integrated bench-scale system combining the attributes of the bio-renewable enzyme carbonic anhydrase (CA) with low-enthalpy CO2 absorption solvents and vacuum regeneration was designed, built and operated for 500 hours using simulated flue gas. The objective was to develop a CO2 capture process with improved efficiency and sustainability when compared to NETL Case 10 monoethanolamine (MEA) scrubbing technology. The use of CA accelerates inter-conversion between dissolved CO2 and bicarbonate ion to enhance CO2 absorption, and the use of low enthalpy CO2 absorption solvents makes it possible to regenerate the solvent at lower temperatures relative to the reference MEA-based solvent. Themore » vacuum regeneration-based integrated bench-scale system operated successfully for an accumulated 500 hours using aqueous 23.5 wt% K2CO3-based solvent containing 2.5 g/L enzyme to deliver an average 84% CO2 capture when operated with a 20% enzyme replenishment rate per ~7 hour steady-state run period. The total inlet gas flow was 30 standard liters per minute with 15% CO2 and 85% N2. The absorber temperature was 40°C and the stripper operated under 35 kPa pressure with an approximate 77°C stripper bottom temperature. Tests with a 30°C absorber temperature delivered >90% capture. On- and off-line operational measurements provided a full process data set, with recirculating enzyme, that allowed for enzyme replenishment and absorption/desorption kinetic parameter calculations. Dissolved enzyme replenishment and conventional process controls were demonstrated as straightforward approaches to maintain system performance. Preliminary evaluation of a novel flow-through ultrasonically enhanced regeneration system was also conducted, yet resulted in CO2 release within the range of temperature-dependent release, and further work would be needed to validate the benefits of ultrasonic enhanced stripping. A full technology assessment was completed in which four techno-economic cases for enzyme-enhanced aqueous K2CO3 solvent with vacuum stripping were considered and a corresponding set of sensitivity studies were developed. The cases were evaluated using bench-scale and laboratory-based observations, AspenPlus® process simulation and modeling, AspenTech’s CCE® Parametric Software, current vendor quotations, and project partners’ know-how of unit operations. Overall, the DOE target of 90% CO2 capture could be met using the benign enzyme-enhanced aqueous K2CO3-based alternative to NETL Case 10. The model-predicted plant COE performance, scaled to 550 MWe net output, was 9% higher than NETL Case 10 for an enzyme-activated case with minimized technical risk and highest confidence in physical system performance utilizing commercially available equipment. A COE improvement of 2.8% versus NETL Case 10 was predicted when favorable features of improved enzyme longevity and additional power output from a very low pressure (VLP) turbine were combined, wherein corresponding high capital and operational costs limited the level of COE benefit. The environmental, health and safety (EH&S) profile of the system was found to be favorable and was compliant with the Federal EH&S legislation reviewed. Further work on a larger scale test unit is recommended to reduce the level of uncertainty inherent in extrapolating findings from a bench-scale unit to a full scale PCC plant, and to further investigate several identified opportunities for improvement. Production feasibility and suitability of carbonic anhydrases for scale-up testing was confirmed both through the current project and through parallel efforts.« less
This document presents summary data on the results of various treatability studies (bench and pilot scale), conducted at three different sites where soils were contaminated with dioxins or PCBs. The synopsis is meant to show rough performance levels under a variety of differen...
40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)
Code of Federal Regulations, 2012 CFR
2012-07-01
.... VII Appendix VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging...
40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)
Code of Federal Regulations, 2013 CFR
2013-07-01
.... VII Appendix VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging...
NASA Technical Reports Server (NTRS)
Durin, Christian; Berthoud, Lucinda; Mandeville, Jean-Claude
1995-01-01
The work carried out over the past three years on FRECOPA and the LDEF has enabled a large quantity of information to be collected, part of which has already been exploited. As far as CNES is concerned, the major spin-offs of this mission mainly focus on the orbital environment and the behavior of materials in such an environment. With respect to the environment, the authors shall develop the lessons learned from expert appraisals on impacts by microparticles, which are the main feature observed in this area. As for the materials, the results show a variety of behavior when subjected to the space environment and even now constitute a wealth of information for the designing and validation of future mechanical systems. Apart from these direct spin-offs, there are repercussions on in-flight and ground testing, the calibration of test benches and improvements to simulation models.
Endoscope shaft-rigidity control mechanism: "FORGUIDE".
Loeve, Arjo J; Plettenburg, Dick H; Breedveld, Paul; Dankelman, Jenny
2012-02-01
Recent developments in flexible endoscopy and other fields of medical technology have raised the need for compact slender shafts that can be made rigid and compliant at will. A novel compact mechanism, named FORGUIDE, with this functionality was developed. The FORGUIDE shaft rigidifies due to friction between a ring of cables situated between a spring and an inflated tube. A mathematical model for the FORGUIDE mechanism working principle was made and used to obtain understanding of this mechanism, predict the maximum rigidity of a FORGUIDE shaft design, and tune its design variables. The mathematical model gave suggestions for significant performance improvement by fine-tuning the design. A prototype FORGUIDE shaft was built and put to a series of bench tests. These tests showed that the FORGUIDE mechanism provides a reliable and simple way to control the rigidity of a flexible shaft. © 2011 IEEE
Design, fabrication, and bench testing of a solar chemical receiver
NASA Technical Reports Server (NTRS)
Summers, W. A.; Pierre, J. F.
1981-01-01
Solar thermal energy can be effectively collected, transported, stored, and utilized by means of a chemical storage and transport system employing the reversible SO2 oxidation reaction. A solar chemical receiver for SO3 thermal decomposition to SO2 and oxygen was analyzed. Bench tests of a ten foot section of a receiver module were conducted with dissociated sulfuric acid (SO3 and H2O) in an electrical furnace. Measured percent conversion of SO3 was 85% of the equilibrium value. Methods were developed to fabricate and assemble a complete receiver module. These methods included applying an aluminide coating to certain exposed surfaces, assembling concentric tubes with a wire spacer, applying a platinum catalyst to the tubing wall, and coiling the entire assembly into the desired configuration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rich, S.R.
1987-02-01
The report gives results of preliminary performance evaluations and economic analyses of the Advanced Energy Dynamics (AED) electrostatic dry coal-cleaning process. Grab samples of coal-feed-product coals were obtained from 25 operating physical coal-cleaning (PCC) plants. These samples were analyzed for ash, sulfur, and energy content and splits of the original samples of feed run-of-mine coal were provided for bench-scale testing in an electrostatic separation apparatus. The process showed superior sulfur-removal performance at equivalent cost and energy-recovery levels. The ash-removal capability of the process was not evaluated completely: overall, ash-removal results indicated that the process did not perform as well asmore » the PCC plants.« less
SRB/SLEEC (Solid Rocket Booster/Shingle Lap Extendible Exit Cone) feasibility study, volume 1
NASA Technical Reports Server (NTRS)
Baker, William H., Jr.
1986-01-01
A preliminary design and analysis was completed for a SLEEC (Shingle Lap Extendible Exit Cone) which could be incorporated on the Space Transportation System (STS) Solid Rocket Booster (SRB). Studies were completed which predicted weights and performance increases and development plans were prepared for the full-scale bench and static test of SLEEC. In conjunction with the design studies, a series of supporting analyses were performed to assure the validity and feasibility of performance, fabrication, cost, and reliability for the selected design. The feasibility and required amounts of bench, static firing, and flight tests considered necessary for the successful incorporation of SLEEC on the Shuttle SRBs were determined. Preliminary plans were completed which define both a follow on study effort and a development program.
Gonté, Frédéric; Dupuy, Christophe; Luong, Bruno; Frank, Christoph; Brast, Roland; Sedghi, Baback
2009-11-10
The primary mirror of the future European Extremely Large Telescope will be equipped with 984 hexagonal segments. The alignment of the segments in piston, tip, and tilt within a few nanometers requires an optical phasing sensor. A test bench has been designed to study four different optical phasing sensor technologies. The core element of the test bench is an active segmented mirror composed of 61 flat hexagonal segments with a size of 17 mm side to side. Each of them can be controlled in piston, tip, and tilt by three piezoactuators with a precision better than 1 nm. The context of this development, the requirements, the design, and the integration of this system are explained. The first results on the final precision obtained in closed-loop control are also presented.
DOT National Transportation Integrated Search
2017-04-28
The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...
Testing of Lightweight Fuel Cell Vehicles System at Low Speeds with Energy Efficiency Analysis
NASA Astrophysics Data System (ADS)
Mustaffa, Muhammad Rizuwan B.; Mohamed, Wan Ahmad Najmi B. Wan
2013-12-01
A fuel cell vehicle power train mini test bench was developed which consists of a 1 kW open cathode hydrogen fuel cell, electric motor, wheel, gearing system, DC/DC converter and vehicle control system (VCS). Energy efficiency identification and energy flow evaluation is a useful tool in identifying a detail performance of each component and sub-systems in a fuel cell vehicle system configuration. Three artificial traction loads was simulated at 30 kg, 40 kg and 50 kg force on a single wheel drive configuration. The wheel speed range reported here covers from idle to 16 km/h (low speed range) as a preliminary input in the research work frame. The test result shows that the system efficiency is 84.5 percent when the energy flow is considered from the fuel cell to the wheel and 279 watts of electrical power was produced by the fuel cell during that time. Dynamic system responses was also identified as the load increases beyond the motor traction capabilities where the losses at the converter and motor controller increased significantly as it tries to meet the motor traction power demands. This work is currently being further expanded within the work frame of developing a road-worthy fuel cell vehicle.
LISA pathfinder optical interferometry
NASA Astrophysics Data System (ADS)
Braxmaier, Claus; Heinzel, Gerhard; Middleton, Kevin F.; Caldwell, Martin E.; Konrad, W.; Stockburger, H.; Lucarelli, S.; te Plate, Maurice B.; Wand, V.; Garcia, A. C.; Draaisma, F.; Pijnenburg, J.; Robertson, D. I.; Killow, Christian; Ward, Harry; Danzmann, Karsten; Johann, Ulrich A.
2004-09-01
The LISA Technology Package (LTP) aboard of LISA pathfinder mission is dedicated to demonstrate and verify key technologies for LISA, in particular drag free control, ultra-precise laser interferometry and gravitational sensor. Two inertial sensor, the optical interferometry in between combined with the dimensional stable Glass ceramic Zerodur structure are setting up the LTP. The validation of drag free operation of the spacecraft is planned by measuring laser interferometrically the relative displacement and tilt between two test masses (and the optical bench) with a noise levels of 10pm/√Hz and 10 nrad/√Hz between 3mHz and 30mHz. This performance and additionally overall environmental tests was currently verified on EM level. The OB structure is able to support two inertial sensors (≍17kg each) and to withstand 25 g design loads as well as 0...40°C temperature range. Optical functionality was verified successfully after environmental tests. The engineering model development and manufacturing of the optical bench and interferometry hardware and their verification tests will be presented.
Removal of adenovirus, calicivirus, and bacteriophages by conventional drinking water treatment.
Abbaszadegan, Morteza; Monteiro, Patricia; Nwachuku, Nena; Alum, Absar; Ryu, Hodon
2008-02-01
This study was conducted to evaluate the removal of adenovirus, feline calicivirus (FCV), and bacteriophages MS-2, fr, PRD-1, and Phi X-174 during conventional drinking water treatment using ferric chloride as a coagulant. Adenovirus and FCV were removed to a greater extent than PRD-1 and Phi X-174, indicating that these bacteriophages may be appropriate surrogates for both adenovirus and FCV. Of the four bacteriophages studied in the pilot plant, MS-2 was removed to the greatest extent (5.1 log), followed by fr (4.9 log), PRD-1 (3.5 log), and Phi X-174 (1.3 log). The virus removal trend in the pilot-scale testing was similar to the bench-scale testing; however, the bench-scale testing seemed to provide a conservative estimate of the pilot plant performance. In the pilot-scale testing, MS-2 and fr were removed with the greatest efficiency during filtration, whereas PRD-1 and Phi X-174 showed the greatest removal during sedimentation.
A squid-based beam current monitor for FAIR/CRYRING
NASA Astrophysics Data System (ADS)
Geithner, Rene; Kurian, Febin; Reeg, Hansjörg; Schwickert, Marcus; Neubert, Ralf; Seidel, Paul; Stöhlker, Thomas
2015-11-01
A SQUID-based beam current monitor was developed for the upcoming FAIR-Project, providing a non-destructive online monitoring of the beam currents in the nA-range. The cryogenic current comparator (CCC) was optimized for lowest possible noise-limited current resolution together with a high system bandwidth. This CCC is foreseen to be installed in the CRYRING facility (CRYRING@ESR: A study group report www.gsi.de/fileadmin/SPARC/documents/Cryring/ReportCryring_40ESR.PDF), working as a test bench for FAIR. In this contribution we present results of the completed CCC for FAIR/CRYRING and also arrangements that have been done for the installation of the CCC at CRYRING, regarding the cryostat design.
Unger, Jakob; Schuster, Maria; Hecker, Dietmar J; Schick, Bernhard; Lohscheller, Jörg
2016-01-01
This work presents a computer-based approach to analyze the two-dimensional vocal fold dynamics of endoscopic high-speed videos, and constitutes an extension and generalization of a previously proposed wavelet-based procedure. While most approaches aim for analyzing sustained phonation conditions, the proposed method allows for a clinically adequate analysis of both dynamic as well as sustained phonation paradigms. The analysis procedure is based on a spatio-temporal visualization technique, the phonovibrogram, that facilitates the documentation of the visible laryngeal dynamics. From the phonovibrogram, a low-dimensional set of features is computed using a principle component analysis strategy that quantifies the type of vibration patterns, irregularity, lateral symmetry and synchronicity, as a function of time. Two different test bench data sets are used to validate the approach: (I) 150 healthy and pathologic subjects examined during sustained phonation. (II) 20 healthy and pathologic subjects that were examined twice: during sustained phonation and a glissando from a low to a higher fundamental frequency. In order to assess the discriminative power of the extracted features, a Support Vector Machine is trained to distinguish between physiologic and pathologic vibrations. The results for sustained phonation sequences are compared to the previous approach. Finally, the classification performance of the stationary analyzing procedure is compared to the transient analysis of the glissando maneuver. For the first test bench the proposed procedure outperformed the previous approach (proposed feature set: accuracy: 91.3%, sensitivity: 80%, specificity: 97%, previous approach: accuracy: 89.3%, sensitivity: 76%, specificity: 96%). Comparing the classification performance of the second test bench further corroborates that analyzing transient paradigms provides clear additional diagnostic value (glissando maneuver: accuracy: 90%, sensitivity: 100%, specificity: 80%, sustained phonation: accuracy: 75%, sensitivity: 80%, specificity: 70%). The incorporation of parameters describing the temporal evolvement of vocal fold vibration clearly improves the automatic identification of pathologic vibration patterns. Furthermore, incorporating a dynamic phonation paradigm provides additional valuable information about the underlying laryngeal dynamics that cannot be derived from sustained conditions. The proposed generalized approach provides a better overall classification performance than the previous approach, and hence constitutes a new advantageous tool for an improved clinical diagnosis of voice disorders. Copyright © 2015 Elsevier B.V. All rights reserved.
Fixture facilitates soldering operations
NASA Technical Reports Server (NTRS)
White, C. M.
1968-01-01
Soldering fixture, designed for printed circuit cards, is a basic bench-mounted, self-contained integral unit combining all soldering needs into a compact, readily available work station. All tools, materials, and accessories are available to provide an ideal station to perform critical soldering.
Janakiraman, Vijay; Kwiatkowski, Chris; Kshirsagar, Rashmi; Ryll, Thomas; Huang, Yao-Ming
2015-01-01
High-throughput systems and processes have typically been targeted for process development and optimization in the bioprocessing industry. For process characterization, bench scale bioreactors have been the system of choice. Due to the need for performing different process conditions for multiple process parameters, the process characterization studies typically span several months and are considered time and resource intensive. In this study, we have shown the application of a high-throughput mini-bioreactor system viz. the Advanced Microscale Bioreactor (ambr15(TM) ), to perform process characterization in less than a month and develop an input control strategy. As a pre-requisite to process characterization, a scale-down model was first developed in the ambr system (15 mL) using statistical multivariate analysis techniques that showed comparability with both manufacturing scale (15,000 L) and bench scale (5 L). Volumetric sparge rates were matched between ambr and manufacturing scale, and the ambr process matched the pCO2 profiles as well as several other process and product quality parameters. The scale-down model was used to perform the process characterization DoE study and product quality results were generated. Upon comparison with DoE data from the bench scale bioreactors, similar effects of process parameters on process yield and product quality were identified between the two systems. We used the ambr data for setting action limits for the critical controlled parameters (CCPs), which were comparable to those from bench scale bioreactor data. In other words, the current work shows that the ambr15(TM) system is capable of replacing the bench scale bioreactor system for routine process development and process characterization. © 2015 American Institute of Chemical Engineers.
Lellouche, François; Qader, Siham; Taillé, Solenne; Lyazidi, Aissam; Brochard, Laurent
2014-05-01
During invasive mechanical ventilation, inspired gases must be humidified. We previously showed that high ambient temperature greatly impaired the hygrometric performance of heated wire-heated humidifiers. The aim of this bench and clinical study was to assess the humidification performance of passive and active heat and moisture exchangers (HMEs) and the impact of ambient temperature and ventilator settings. We first tested on the bench a device with passive and active humidification properties (Humid-Heat, Teleflex), and 2 passive hydrophobic/hygroscopic HMEs (Hygrobac and Hygrobac S, Tyco Healthcare). The devices were tested at 3 different ambient temperatures (from 22 to 30 °C), and at 2 minute ventilation settings (10 and 20 L/min). Inspired gas hygrometry was measured at the Y-piece with the psychrometric method. In addition to the bench study, we measured the hygrometry of inspired gases in 2 different clinical studies. In 15 mechanically ventilated patients, we evaluated Humid-Heat at different settings. Additionally, we evaluated Humid-Heat and compared it with Hygrobac in a crossover study in 10 patients. On the bench, with the Hygrobac and Hygrobac S the inspired absolute humidity was ∼ 30 mg H2O/L, and with the Humid-Heat, slightly < 35 mg H2O/L. Ambient temperature and minute ventilation did not have a clinically important difference on the performance of the tested devices. During the clinical evaluation, Humid-Heat provided inspired humidity in a range from 28.5 to 42.0 mg H2O/L, depending on settings, and was only weakly influenced by the patient's body temperature. In this study both passive and active HMEs had stable humidification performance with negligible influence of ambient temperature and minute ventilation. This contrasts with previous findings with heated wire-heated humidifiers. Although there are no clear data demonstrating that higher humidification impacts outcomes, it is worth noting that humidity was significantly higher with the active HME.
Integrated vision-based GNC for autonomous rendezvous and capture around Mars
NASA Astrophysics Data System (ADS)
Strippoli, L.; Novelli, G.; Gil Fernandez, J.; Colmenarejo, P.; Le Peuvedic, C.; Lanza, P.; Ankersen, F.
2015-06-01
Integrated GNC (iGNC) is an activity aimed at designing, developing and validating the GNC for autonomously performing the rendezvous and capture phase of the Mars sample return mission as defined during the Mars sample return Orbiter (MSRO) ESA study. The validation cycle includes testing in an end-to-end simulator, in a real-time avionics-representative test bench and, finally, in a dynamic HW in the loop test bench for assessing the feasibility, performances and figure of merits of the baseline approach defined during the MSRO study, for both nominal and contingency scenarios. The on-board software (OBSW) is tailored to work with the sensors, actuators and orbits baseline proposed in MSRO. The whole rendezvous is based on optical navigation, aided by RF-Doppler during the search and first orbit determination of the orbiting sample. The simulated rendezvous phase includes also the non-linear orbit synchronization, based on a dedicated non-linear guidance algorithm robust to Mars ascent vehicle (MAV) injection accuracy or MAV failures resulting in elliptic target orbits. The search phase is very demanding for the image processing (IP) due to the very high visual magnitude of the target wrt. the stellar background, and the attitude GNC requires very high pointing stability accuracies to fulfil IP constraints. A trade-off of innovative, autonomous navigation filters indicates the unscented Kalman filter (UKF) as the approach that provides the best results in terms of robustness, response to non-linearities and performances compatibly with computational load. At short range, an optimized IP based on a convex hull algorithm has been developed in order to guarantee LoS and range measurements from hundreds of metres to capture.
Lockie, Robert G.; Callaghan, Samuel J.; Moreno, Matthew R.; Risso, Fabrice G.; Liu, Tricia M.; Stage, Alyssa A.; Birmingham-Babauta, Samantha A.; Stokes, John J.; Giuliano, Dominic V.; Lazar, Adrina; Davis, DeShaun L.; Orjalo, Ashley J.
2017-01-01
The close-grip bench press (CGBP) is a variation of the traditional bench press (TBP) that uses a narrower grip (~95% of biacromial distance (BAD)) and has potential application for athletes performing explosive arm actions from positions where the hands are held close to the torso. Limited research has investigated CGBP mechanics compared to the TBP. Twenty-seven resistance-trained individuals completed a one-repetition maximum TBP and CGBP. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% BAD. A linear position transducer measured lift distance and duration; peak and mean power, velocity, and force; distance and time when peak power occurred; and work. Pre-sticking region (PrSR), sticking region, and post-sticking region distance and duration for each lift was measured. A repeated measures ANOVA was used to derive differences between TBP and CGBP mechanics (p < 0.01); effect sizes (d) were also calculated. A greater load was lifted in the TBP, thus mean force was greater (d = 0.16–0.17). Peak power and velocity were higher in the CGBP, which had a longer PrSR distance (d = 0.49–1.32). The CGBP could emphasize power for athletes that initiate explosive upper-body actions with the hands positioned close to the torso.
PEROXIDE DESTRUCTION TESTING FOR THE 200 AREA EFFLUENT TREATMENT FACILITY
DOE Office of Scientific and Technical Information (OSTI.GOV)
HALGREN DL
2010-03-12
The hydrogen peroxide decomposer columns at the 200 Area Effluent Treatment Facility (ETF) have been taken out of service due to ongoing problems with particulate fines and poor destruction performance from the granular activated carbon (GAC) used in the columns. An alternative search was initiated and led to bench scale testing and then pilot scale testing. Based on the bench scale testing three manganese dioxide based catalysts were evaluated in the peroxide destruction pilot column installed at the 300 Area Treated Effluent Disposal Facility. The ten inch diameter, nine foot tall, clear polyvinyl chloride (PVC) column allowed for the samemore » six foot catalyst bed depth as is in the existing ETF system. The flow rate to the column was controlled to evaluate the performance at the same superficial velocity (gpm/ft{sup 2}) as the full scale design flow and normal process flow. Each catalyst was evaluated on peroxide destruction performance and particulate fines capacity and carryover. Peroxide destruction was measured by hydrogen peroxide concentration analysis of samples taken before and after the column. The presence of fines in the column headspace and the discharge from carryover was generally assessed by visual observation. All three catalysts met the peroxide destruction criteria by achieving hydrogen peroxide discharge concentrations of less than 0.5 mg/L at the design flow with inlet peroxide concentrations greater than 100 mg/L. The Sud-Chemie T-2525 catalyst was markedly better in the minimization of fines and particle carryover. It is anticipated the T-2525 can be installed as a direct replacement for the GAC in the peroxide decomposer columns. Based on the results of the peroxide method development work the recommendation is to purchase the T-2525 catalyst and initially load one of the ETF decomposer columns for full scale testing.« less
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES IIsD Side Impact Crash Test Dummy... impacted side removed. The dummy is equipped with a lower spine laterally oriented accelerometer as... side of the seated dummy tangent to a vertical plane located within 10 mm of the side edge of the bench...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES IIsD Side Impact Crash Test Dummy... impacted side removed. The dummy is equipped with a lower spine laterally oriented accelerometer as... side of the seated dummy tangent to a vertical plane located within 10 mm of the side edge of the bench...
THE U.S. ENVIRONMENTAL PROTECTION AGENCY'S SITE EMERGING TECHNOLOGY PROGRAM
Under the SITE Emerging Technology Program, the U.S. Environmental Protection Agency is seeking to foster the further development of technol- ogies that have been successfully tested at bench-scale and are now ready for pilot-scale testing, prior to field- or full-scale demonstra...
Predicting Power Output of Upper Body using the OMNI-RES Scale.
Bautista, Iker J; Chirosa, Ignacio J; Tamayo, Ignacio Martín; González, Andrés; Robinson, Joseph E; Chirosa, Luis J; Robertson, Robert J
2014-12-09
The main aim of this study was to determine the optimal training zone for maximum power output. This was to be achieved through estimating mean bar velocity of the concentric phase of a bench press using a prediction equation. The values for the prediction equation would be obtained using OMNI-RES scale values of different loads of the bench press exercise. Sixty males (age 23.61 2.81 year; body height 176.29 6.73 cm; body mass 73.28 4.75 kg) voluntarily participated in the study and were tested using an incremental protocol on a Smith machine to determine one repetition maximum (1RM) in the bench press exercise. A linear regression analysis produced a strong correlation (r = -0.94) between rating of perceived exertion (RPE) and mean bar velocity (Velmean). The Pearson correlation analysis between real power output (PotReal) and estimated power (PotEst) showed a strong correlation coefficient of r = 0.77, significant at a level of p = 0.01. Therefore, the OMNI-RES scale can be used to predict Velmean in the bench press exercise to control the intensity of the exercise. The positive relationship between PotReal and PotEst allowed for the identification of a maximum power-training zone.
Predicting Power Output of Upper Body using the OMNI-RES Scale
Bautista, Iker J.; Chirosa, Ignacio J.; Tamayo, Ignacio Martín; González, Andrés; Robinson, Joseph E.; Chirosa, Luis J.; Robertson, Robert J.
2014-01-01
The main aim of this study was to determine the optimal training zone for maximum power output. This was to be achieved through estimating mean bar velocity of the concentric phase of a bench press using a prediction equation. The values for the prediction equation would be obtained using OMNI–RES scale values of different loads of the bench press exercise. Sixty males (age 23.61 2.81 year; body height 176.29 6.73 cm; body mass 73.28 4.75 kg) voluntarily participated in the study and were tested using an incremental protocol on a Smith machine to determine one repetition maximum (1RM) in the bench press exercise. A linear regression analysis produced a strong correlation (r = −0.94) between rating of perceived exertion (RPE) and mean bar velocity (Velmean). The Pearson correlation analysis between real power output (PotReal) and estimated power (PotEst) showed a strong correlation coefficient of r = 0.77, significant at a level of p = 0.01. Therefore, the OMNI–RES scale can be used to predict Velmean in the bench press exercise to control the intensity of the exercise. The positive relationship between PotReal and PotEst allowed for the identification of a maximum power-training zone. PMID:25713677
42 CFR 84.207 - Bench tests; gas and vapor tests; minimum requirements; general.
Code of Federal Regulations, 2013 CFR
2013-10-01
....) Flowrate (l.p.m.) Number of tests Penetration 1 (p.p.m.) Minimum life 2 (min.) Ammonia As received NH3 1000... minimum life shall be one-half that shown for each type of gas or vapor. Where a respirator is designed... at predetermined concentrations and rates of flow, and that has means for determining the test life...
42 CFR 84.207 - Bench tests; gas and vapor tests; minimum requirements; general.
Code of Federal Regulations, 2014 CFR
2014-10-01
....) Flowrate (l.p.m.) Number of tests Penetration 1 (p.p.m.) Minimum life 2 (min.) Ammonia As received NH3 1000... minimum life shall be one-half that shown for each type of gas or vapor. Where a respirator is designed... at predetermined concentrations and rates of flow, and that has means for determining the test life...
42 CFR 84.207 - Bench tests; gas and vapor tests; minimum requirements; general.
Code of Federal Regulations, 2012 CFR
2012-10-01
....) Flowrate (l.p.m.) Number of tests Penetration 1 (p.p.m.) Minimum life 2 (min.) Ammonia As received NH3 1000... minimum life shall be one-half that shown for each type of gas or vapor. Where a respirator is designed... at predetermined concentrations and rates of flow, and that has means for determining the test life...
Analysis of Skeletal Muscle Metrics as Predictors of Functional Task Performance
NASA Technical Reports Server (NTRS)
Ryder, Jeffrey W.; Buxton, Roxanne E.; Redd, Elizabeth; Scott-Pandorf, Melissa; Hackney, Kyle J.; Fiedler, James; Ploutz-Snyder, Robert J.; Bloomberg, Jacob J.; Ploutz-Snyder, Lori L.
2010-01-01
PURPOSE: The ability to predict task performance using physiological performance metrics is vital to ensure that astronauts can execute their jobs safely and effectively. This investigation used a weighted suit to evaluate task performance at various ratios of strength, power, and endurance to body weight. METHODS: Twenty subjects completed muscle performance tests and functional tasks representative of those that would be required of astronauts during planetary exploration (see table for specific tests/tasks). Subjects performed functional tasks while wearing a weighted suit with additional loads ranging from 0-120% of initial body weight. Performance metrics were time to completion for all tasks except hatch opening, which consisted of total work. Task performance metrics were plotted against muscle metrics normalized to "body weight" (subject weight + external load; BW) for each trial. Fractional polynomial regression was used to model the relationship between muscle and task performance. CONCLUSION: LPMIF/BW is the best predictor of performance for predominantly lower-body tasks that are ambulatory and of short duration. LPMIF/BW is a very practical predictor of occupational task performance as it is quick and relatively safe to perform. Accordingly, bench press work best predicts hatch-opening work performance.
Electrochemical Membrane for Carbon Dioxide Capture and Power Generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghezel-Ayagh, Hossein
FuelCell Energy, Inc. (FCE), in collaboration with AECOM Corporation (formerly URS Corporation) and Pacific Northwest National Laboratory, has been developing a novel Combined Electric Power and Carbon-dioxide Separation (CEPACS) system. The CEPACS system is based on electrochemical membrane (ECM) technology derived from FCE’s carbonate fuel cell products featuring internal (methane steam) reforming and carrying the trade name of Direct FuelCell®. The unique chemistry of carbonate fuel cells offers an innovative approach for separation of CO 2 from existing fossil-fuel power plant exhaust streams (flue gases). The ECM-based CEPACS system has the potential to become a transformational CO 2-separation technology bymore » working as two devices in one: it separates the CO 2 from the exhaust of other plants such as an existing coal-fired plant and simultaneously produces clean electric power at high efficiency using a supplementary fuel. The development effort was carried out under the U.S. Department of Energy (DOE) cooperative agreement DE-FE0007634. The overall objective of this project was to successfully demonstrate the ability of FCE’s ECM-based CEPACS system technology to separate ≥90% of the CO 2 from a simulated Pulverized Coal (PC) power plant flue gas stream and to compress the captured CO2 to a state that can be easily transported for sequestration or beneficial use. In addition, a key objective was to show, through the technical and economic feasibility study and bench scale testing, that the ECM-based CEPACS system is an economical alternative for CO 2 capture in PC power plants, and that it meets DOE’s objective related to the incremental cost of electricity (COE) for post-combustion CO 2 capture (no more than 35% increase in COE). The project was performed in three budget periods (BP). The specific objective for BP1 was to complete the Preliminary Technical and Economic Feasibility Study. The T&EF study was based on the carbon capture system size suitable for a reference 550 MW PC power plant. The specific objectives for BP2 were to perform (flue gas) contaminant effect evaluation tests, small area membrane tests using clean simulated flue gas, design a flue gas pretreatment system for processing of the gas feed to ECM, update the Technical & Economic Feasibility Study (T&EFS) incorporating results of contaminant effect tests and small area membrane tests, and to prepare a test facility for bench scale testing. The specific objectives for BP3 were to perform bench scale testing (parametric and long-duration testing) of a 11.7 m 2 ECM-based CO 2 capture, purification and compression system, and update (as final) the Technical and Economic Feasibility Study. In addition, an Environmental Health and Safety evaluation (assessment) of the ECM technology was included. This final technical report presents the progress made under the project.« less
Ilie, Marius; Khambata-Ford, Shirin; Copie-Bergman, Christiane; Huang, Lingkang; Juco, Jonathan; Hofman, Veronique; Hofman, Paul
2017-01-01
For non-small cell lung cancer (NSCLC), treatment with pembrolizumab is limited to patients with tumours expressing PD-L1 assessed by immunohistochemistry (IHC) using the PD-L1 IHC 22C3 pharmDx (Dako, Inc.) companion diagnostic test, on the Dako Autostainer Link 48 (ASL48) platform. Optimised protocols are urgently needed for use of the 22C3 antibody concentrate to test PD-L1 expression on more widely available IHC autostainers. We evaluated PD-L1 expression using the 22C3 antibody concentrate in the three main commercially available autostainers Dako ASL48, BenchMark ULTRA (Ventana Medical Systems, Inc.), and Bond-III (Leica Biosystems) and compared the staining results with the PD-L1 IHC 22C3 pharmDx kit on the Dako ASL48 platform. Several technical conditions for laboratory-developed tests (LDTs) were evaluated in tonsil specimens and a training set of three NSCLC samples. Optimised protocols were then validated in 120 NSCLC specimens. Optimised protocols were obtained on both the VENTANA BenchMark ULTRA and Dako ASL48 platforms. Significant expression of PD-L1 was obtained on tissue controls with the Leica Bond-III autostainer when high concentrations of the 22C3 antibody were used. It therefore was not tested on the 120 NSCLC specimens. An almost 100% concordance rate for dichotomized tumour proportion score (TPS) results was observed between TPS ratings using the 22C3 antibody concentrate on the Dako ASL48 and VENTANA BenchMark ULTRA platforms relative to the PD-L1 IHC 22C3 pharmDx kit on the Dako ASL48 platform. Interpathologist agreement was high on both LDTs and the PD-L1 IHC 22C3 pharmDx kit on the Dako ASL48 platform. Availability of standardized protocols for determining PD-L1 expression using the 22C3 antibody concentrate on the widely available Dako ASL48 and VENTANA BenchMark ULTRA IHC platforms will expand the number of laboratories able to determine eligibility of patients with NSCLC for treatment with pembrolizumab in a reliable and concordant manner.
Wall and corner fire tests on selected wood products
H. C. Tran; M. L. Janssens
1991-01-01
As part of a fire growth program to develop and validate a compartment fire model, several bench-scale and full-scale tests were conducted. This paper reports the full-scale wall and corner test results of step 2 of this study. A room fire test following the ASTM proposed standard specifications was used for these full-scale tests. In step 1, we investigated the...
Depositional history of the Fire Clay coal bed (Late Duckmantian), Eastern Kentucky, USA
Greb, S.F.; Eble, C.F.; Hower, J.C.
1999-01-01
More than 3800 coal thickness measurements, proximate analyses from 97 localities, and stratigraphic and sedimentological analyses from more than 300 outcrops and cores were used in conjunction with previously reported palynological and petrographic studies to map individual benches of the coal and document bench-scale variability in the Fire Clay (Hazard No. 4) coal bed across a 1860 km2 area of the Eastern Kentucky Coal Field. The bench architecture of the Fire Clay coal bed consists of uncommon leader benches, a persistent but variable lower bench, a widespread, and generally thick upper bench, and local, variable rider benches. Rheotrophic conditions are inferred for the leader benches and lower bench based on sedimentological associations, mixed palynomorph assemblages, locally common cannel coal layers, and generally high ash yields. The lower bench consistently exhibits vertical variability in petrography and palynology that reflects changing trophic conditions as topographic depressions infilled. Infilling also led to unconfined flooding and ultimately the drowning of the lower bench mire. The drowned mire was covered by an air-fall volcanic-ash deposit, which produced the characteristic flint clay parting. The extent and uniform thickness of the parting suggests that the ash layer was deposited in water on a relatively flat surface without a thick canopy or extensive standing vegetation across most of the study area. Ash deposits led to regional ponding and establishment of a second planar mire. Because the topography had become a broadly uniform, nutrient-rich surface, upper-bench peats became widespread with large areas of the mire distant to clastic sources. Vertical sections of thick (> 70 cm), low-ash yield, upper coal bench show a common palynomorph change from arborescent lycopod dominance upward to fern and densospore-producing, small lycopod dominance, inferred as a shift from planar to ombrotrophic mire phases. Domed mires appear to have been surrounded by wide areas of planar mires, where the coal was thinner (< 70 cm), higher in ash yield, and dominated by arborescent lycopods. Rectangular thickness trends suggest that syndepositional faulting influenced peat accumulation, and possibly the position of the domed mire phase. Faulting also influenced post-depositional clastic environments of deposition, resulting in sandstone channels with angular changes in orientation. Channels and lateral facies were locally draped by high-ash-yield rider coal benches, which sometimes merged with the upper coal bench. These arborescent-lycopod dominant rider coal benches were profoundly controlled by palcotopography, much like the leader coal benches. Each of the benches of coal documented here represent distinctly different mires that came together to form the Fire Clay coal bed, rather than a single mire periodically split by clastic influx. This is significant as each bench of the coal has its own characteristics, which contribute to the total coal characteristics. The large data set allows interpretation of both vertical and lateral limits to postulated domed phases in the upper coal bench, and to the delineation of subtle tectonic structures that allow for meaningful thickness projections beyond the limits of present mining.A study was conducted to analyze the depositional history of the Fire Clay coal bed in the eastern Kentucky coal field. The study involved over 3800 coal thickness measurements, proximate analyses from 97 localities, and stratigraphic and sedimentological analyses from more than 300 outcrops and cores in conjunction with previously reported palynological and petrographic studies to map individual benches of the coal and document bench-scale variability.
Novel Approach to Simulate Sleep Apnea Patients for Evaluating Positive Pressure Therapy Devices.
Isetta, Valentina; Montserrat, Josep M; Santano, Raquel; Wimms, Alison J; Ramanan, Dinesh; Woehrle, Holger; Navajas, Daniel; Farré, Ramon
2016-01-01
Bench testing is a useful method to characterize the response of different automatic positive airway pressure (APAP) devices under well-controlled conditions. However, previous models did not consider the diversity of obstructive sleep apnea (OSA) patients' characteristics and phenotypes. The objective of this proof-of-concept study was to design a new bench test for realistically simulating an OSA patient's night, and to implement a one-night example of a typical female phenotype for comparing responses to several currently-available APAP devices. We developed a novel approach aimed at replicating a typical night of sleep which includes different disturbed breathing events, disease severities, sleep/wake phases, body postures and respiratory artefacts. The simulated female OSA patient example that we implemented included periods of wake, light sleep and deep sleep with positional changes and was connected to ten different APAP devices. Flow and pressure readings were recorded; each device was tested twice. The new approach for simulating female OSA patients effectively combined a wide variety of disturbed breathing patterns to mimic the response of a predefined patient type. There were marked differences in response between devices; only three were able to overcome flow limitation to normalize breathing, and only five devices were associated with a residual apnea-hypopnea index of <5/h. In conclusion, bench tests can be designed to simulate specific patient characteristics, and typical stages of sleep, body position, and wake. Each APAP device behaved differently when exposed to this controlled model of a female OSA patient, and should lead to further understanding of OSA treatment.
Evaluation of induced seismicity forecast models in the Induced Seismicity Test Bench
NASA Astrophysics Data System (ADS)
Király, Eszter; Gischig, Valentin; Zechar, Jeremy; Doetsch, Joseph; Karvounis, Dimitrios; Wiemer, Stefan
2016-04-01
Induced earthquakes often accompany fluid injection, and the seismic hazard they pose threatens various underground engineering projects. Models to monitor and control induced seismic hazard with traffic light systems should be probabilistic, forward-looking, and updated as new data arrive. Here, we propose an Induced Seismicity Test Bench to test and rank such models. We apply the test bench to data from the Basel 2006 and Soultz-sous-Forêts 2004 geothermal stimulation projects, and we assess forecasts from two models that incorporate a different mix of physical understanding and stochastic representation of the induced sequences: Shapiro in Space (SiS) and Hydraulics and Seismics (HySei). SiS is based on three pillars: the seismicity rate is computed with help of the seismogenic index and a simple exponential decay of the seismicity; the magnitude distribution follows the Gutenberg-Richter relation; and seismicity is distributed in space based on smoothing seismicity during the learning period with 3D Gaussian kernels. The HySei model describes seismicity triggered by pressure diffusion with irreversible permeability enhancement. Our results show that neither model is fully superior to the other. HySei forecasts the seismicity rate well, but is only mediocre at forecasting the spatial distribution. On the other hand, SiS forecasts the spatial distribution well but not the seismicity rate. The shut-in phase is a difficult moment for both models in both reservoirs: the models tend to underpredict the seismicity rate around, and shortly after, shut-in. Ensemble models that combine HySei's rate forecast with SiS's spatial forecast outperform each individual model.
Bench-scale screening tests for a boiling sodium-potassium alloy solar receiver
NASA Astrophysics Data System (ADS)
Moreno, J. B.; Moss, T. A.
1993-06-01
Bench-scale tests were carried out in support of the design of a second-generation 75-kW(sub t) reflux pool-boiler solar receiver. The receiver will be made from Haynes Alloy 230 and will contain the sodium-potassium alloy NaK-78. The bench-scale tests used quartz lamp heated boilers to screen candidate boiling stabilization materials and methods at temperatures up to 750 degree C. Candidates that provided stable boiling were tested for hot-restart behavior. Poor stability was obtained with single 1/4-inch diameter patches of powdered metal hot press sintered onto the wetted side of the heat-input area. Laser-drilled and electric discharge machined cavities in the heated surface also performed poorly. Small additions of xenon, and heated-surface tilt out of the vertical, dramatically improved poor boiling stability; additions of helium or oxygen did not. The most stable boiling was obtained when the entire heat-input area was covered by a powdered-metal coating. The effect of heated-area size was assessed for one coating: at low incident fluxes, when even this coating performed poorly, increasing the heated-area size markedly improved boiling stability. Good hot-restart behavior was not observed with any candidate, although results were significantly better with added xenon in a boiler shortened from 3 to 2 feet. In addition to the screening tests, flash-radiography imaging of metal-vapor bubbles during boiling was attempted. Contrary to the Cole-Rohsenow correlation, these bubble-size estimates did not vary with pressure; instead they were constant, consistent with the only other alkali metal measurements, but about 1/2 their size.
Cyanobacteria, Toxins and Indicators: Full-Scale Monitoring & Bench-Scale Treatment Studies
Summary of: 1) Lake Erie 2014 bloom season full-scale treatment plant monitoring data for cyanobacteria and cyanobacteria toxins; 2) Follow-up work to examine the impact of pre-oxidation on suspensions of intact toxin-producing cyanobacterial cells.
Laboratory Equipment Criteria.
ERIC Educational Resources Information Center
State Univ. Construction Fund, Albany, NY.
Requirements for planning, designing, constructing and installing laboratory furniture are given in conjunction with establishing facility criteria for housing laboratory equipment. Furniture and equipment described include--(1) center tables, (2) reagent racks, (3) laboratory benches and their mechanical fixtures, (4) sink and work counters, (5)…
Ratamess, Nicholas A; Chiarello, Christina M; Sacco, Anthony J; Hoffman, Jay R; Faigenbaum, Avery D; Ross, Ryan E; Kang, Jie
2012-07-01
The purpose of this study was to investigate the effects of rest interval (RI) length on bench press performance in subjects with disparity in maximum strength. Two cohorts of subjects performed 3 bench press protocols in random order consisting of 3 sets of up to 10 repetitions with 75% of 1-repetition maximum (1RM) using either 1-, 2-, or 3-minute RIs between sets. In the first cohort, 22 men and women were studied to investigate gender influence. In the second cohort, 23 men were tested for 1RM bench press strength and placed into a low 1RM (mean = 80.7 ± 7.5 kg) or high 1RM (mean = 140.6 ± 11.9 kg) experimental group. The number of successful repetitions completed, average power, and velocity for each set were recorded. Women performed significantly more repetitions than men with 1-minute (26.9 ± 4.4 vs. 21.1 ± 3.5), 2-minute (29.0 ± 2.0 vs. 24.0 ± 4.5), and 3-minute (29.7 ± 1.8 vs. 25.8 ± 5.1) RIs. The magnitude of decline in average velocity and power was significantly higher in men than in women. Total number of repetitions performed was significantly greater in the low 1RM group than in the high 1RM group at 1-minute (21.6 ± 5.0 vs. 18.1 ± 2.0) and 2-minute RIs (24.2 ± 5.4 vs. 21.3 ± 2.8). Significant negative correlations were observed between 1RM bench press and total number of repetitions completed for 1- and 2-minute RIs (r = -0.558 and -0.490, respectively). These data indicate that maximal strength plays a role in bench press performance with varying RIs and suggest that shorter RIs may suffice in women to attain a specific volume.
A Simple Workstation for the Conservation of Library Materials.
ERIC Educational Resources Information Center
Conservation Correspondence, 1984
1984-01-01
The first step in designing a work station that is appropriate for both the maintenance and repair of library materials is to determine procedures likely to be necessary based on the nature of the collection and the type of use it receives. Necessary equipment includes a work station with a bench and storage space (an illustration and a list of…
29 CFR 785.34 - Effect of section 4 of the Portal-to-Portal Act.
Code of Federal Regulations, 2010 CFR
2010-07-01
... failure to pay the minimum wage or overtime compensation for time spent in “walking, riding, or traveling... employee is employed to perform either prior to the time on any particular workday at which such employee... from time clock to work-bench) need not be counted as working time unless it is compensable by contract...
2014-02-05
ISS038-E-042747 (5 Feb. 2014) --- Japan Aerospace Exploration Agency astronaut Koichi Wakata, Expedition 38 flight engineer, works on the Combustion Integrated Rack (CIR) in the Destiny laboratory of the International Space Station. This research rack, which includes an optics bench, combustion chamber, fuel and oxidizer control and five different cameras, allows a variety of combustion experiments to be performed safely aboard the station.
2014-02-05
ISS038-E-042754 (5 Feb. 2014) --- Japan Aerospace Exploration Agency astronaut Koichi Wakata, Expedition 38 flight engineer, works on the Combustion Integrated Rack (CIR) in the Destiny laboratory of the International Space Station. This research rack, which includes an optics bench, combustion chamber, fuel and oxidizer control and five different cameras, allows a variety of combustion experiments to be performed safely aboard the station.
2014-02-05
ISS038-E-042758 (5 Feb. 2014) --- Japan Aerospace Exploration Agency astronaut Koichi Wakata, Expedition 38 flight engineer, works on the Combustion Integrated Rack (CIR) in the Destiny laboratory of the International Space Station. This research rack, which includes an optics bench, combustion chamber, fuel and oxidizer control and five different cameras, allows a variety of combustion experiments to be performed safely aboard the station.
Gilleard, W; Smith, T
2007-02-01
Effects of obesity on trunk forward flexion motion in sitting and standing, and postural adaptations and hip joint moment for a standing work task. Cross-sectional comparison of obese and normal weight groups. Ten obese subjects (waist girth 121.2+/-16.8 cm, body mass index (BMI) 38.9+/-6.6 kg m(-2)) and 10 age- and height-matched normal weight subjects (waist girth 79.6+/-6.4 cm, BMI 21.7+/-1.5 kg m(-2)). Trunk motion during seated and standing forward flexion, and trunk posture, hip joint moment and hip-to-bench distance during a simulated standing work task were recorded. Forward flexion motion of the thoracic segment and thoracolumbar spine was decreased for the obese group with no change in pelvic segment and hip joint motion. Obese subjects showed a more flexed trunk posture and increased hip joint moment and hip-to-bench distance for a simulated standing work task. Decreased range of forward flexion motion, differing effects within the trunk, altered posture during a standing work task and concomitant increases in hip joint moment give insight into the aetiology of functional decrements and musculoskeletal pain seen in obesity.
2018-02-09
Nathan Gelino, a NASA research engineer at Kennedy Space Center in Florida displays a 3-D printed cylinder used for compression testing. Engineers at the center’s Swamp Works measured how much force it takes to break the structure before moving on to 3-D printing with a simulated lunar regolith, or dirt, and polymers. Next, Gelino and his group are working on a Zero Launch Mass 3-D printer that can be used for construction projects on the Moon and Mars, even for troops in remote locations here on Earth. Zero launch mass refers to the fact that the printer uses these pellets to prove that space explorers can use resources at their destination instead of taking everything with them, saving them launch mass and money. Gelino and his team are working with Marshall Space Flight Center in Huntsville, Alabama, and the U.S. Army Corps of Engineers to develop a system that can 3-D print barracks in remote locations on Earth, using the resources they have where they are.
Fitness Level Modulates Intraocular Pressure Responses to Strength Exercises.
Vera, Jesús; Jiménez, Raimundo; Redondo, Beatríz; Cárdenas, David; García-Ramos, Amador
2018-06-01
Purpose/Aim: The execution of strength exercises has demonstrated to increase the intraocular pressure (IOP) levels, and it may have a negative impact on the ocular health. We aimed to explore the influence of fitness level on the acute IOP response to strength exercises performed under different loading conditions, as well as to test whether the IOP responses differ between the bench press and jump squat when performed against the same relative loads. Forty military personnel males were divided in two subgroups (20 high-fit and 20 low-fit) based on their relative to body mass one-repetition maximum (1-RM). Participants performed an incremental loading test in the bench press and jump squat exercises, and IOP was assessed before and after each repetition by rebound tonometry. IOP increased immediately after executing both exercises (p < 0.01 in both cases), being the magnitude of the IOP increment positively and linearly associated with the increment of the load in both groups (i.e., high-fit and low-fit) and in both exercises (R 2 range: 0.81-1.00). Higher fitness level attenuated the IOP rise produced by both exercises (p < 0.01 in both cases). The bench press induced higher IOP increments than the jump squat for both groups at relative loads of ~50%1-RM and ~60%1-RM (p < 0.01 in all cases). These data indicate that IOP increases as a consequence of performing strength exercises, being the increment accentuated with the increase of the load and in the bench press compared to the jump squat exercise. Of special importance would be that the IOP responses were significantly reduced in high-fit individuals. These findings should be addressed in glaucoma patients.
García-Ramos, Amador; Padial, Paulino; Haff, G Gregory; Argüelles-Cienfuegos, Javier; García-Ramos, Miguel; Conde-Pipó, Javier; Feriche, Belén
2015-09-01
This study investigated the effect of introducing different interrepetition rest (IRR) periods on the ability to sustain maximum bench press throw velocity with a range of loads commonly used to develop upper-body power. Thirty-four physically active collegiate men (age: 21.5 ± 2.8 years; body mass: 75.2 ± 7.2 kg; height: 176.9 ± 4.9 cm) were tested during 2 consecutive weeks. During the first week, the maximum dynamic strength (repetition maximum [RM]) in bench press exercise was determined (RM = 76.7 ± 13.2 kg). The following week, 3 testing sessions were conducted with 48 hours apart in random order. In each day of evaluation, only 1 load (30%RM, 40%RM, or 50%RM) was assessed in the bench press throw exercise. With each load, subjects performed 3 single sets of 15 repetitions (15-minute interset rest) with 3 different sets configurations: continuous repetitions (CR), 6 seconds of IRR (IRR6), and 12 seconds of IRR (IRR12). The decrease of peak velocity (PV) was significantly lower for IRR12 compared with CR and IRR6 at least since the repetition 4. No differences between CR and IRR6 protocols were found until the repetition 7 at 30%RM and 40%RM and until the repetition 5 at 50%RM. The decrease of PV during the CR protocol was virtually linear for the 3 loads analyzed (r > 0.99); however, this linear relationship became weaker for IRR6 (r = 0.79-0.95) and IRR12 (r = 0.35-0.87). These results demonstrate that IRR periods allow increasing the number of repetitions before the onset of significant velocity losses.
Nicolucci, Antonio; Rossi, Maria C; Pellegrini, Fabio; Lucisano, Giuseppe; Pintaudi, Basilio; Gentile, Sandro; Marra, Giampiero; Skovlund, Soren E; Vespasiani, Giacomo
2014-01-01
In the context of the DAWN-2 initiatives, the BENCH-D Study aims to test a model of regional benchmarking to improve not only the quality of diabetes care, but also patient-centred outcomes. As part of the AMD-Annals quality improvement program, 32 diabetes clinics in 4 Italian regions extracted clinical data from electronic databases for measuring process and outcome quality indicators. A random sample of patients with type 2 diabetes filled in a questionnaire including validated instruments to assess patient-centred indicators: SF-12 Health Survey, WHO-5 Well-Being Index, Diabetes Empowerment Scale, Problem Areas in Diabetes, Health Care Climate Questionnaire, Patients Assessment of Chronic Illness Care, Barriers to Medications, Patient Support, Diabetes Self-care Activities, and Global Satisfaction for Diabetes Treatment. Data were discussed with participants in regional meetings. Main problems, obstacles and solutions were identified through a standardized process, and a regional mandate was produced to drive the priority actions. Overall, clinical indicators on 78,854 patients have been measured; additionally, 2,390 patients filled-in the questionnaire. The regional mandates were officially launched in March 2012. Clinical and patient-centred indicators will be evaluated again after 18 months. A final assessment of clinical indicators will take place after 30 months. In the context of the BENCH-D study, a set of instruments has been validated to measure patient well-being and satisfaction with the care. In the four regional meetings, different priorities were identified, reflecting different organizational resources of the different areas. In all the regions, a major challenge was represented by the need of skills and instruments to address psychosocial issues of people with diabetes. The BENCH-D study allows a field testing of benchmarking activities focused on clinical and patient-centred indicators.
Sañudo, Borja; Rueda, David; Pozo-Cruz, Borja Del; de Hoyo, Moisés; Carrasco, Luis
2016-10-01
Sañudo, B, Rueda, D, del Pozo-Cruz, B, de Hoyo, M, and Carrasco, L. Validation of a video analysis software package for quantifying movement velocity in resistance exercises. J Strength Cond Res 30(10): 2934-2941, 2016-The aim of this study was to establish the validity of a video analysis software package in measuring mean propulsive velocity (MPV) and the maximal velocity during bench press. Twenty-one healthy males (21 ± 1 year) with weight training experience were recruited, and the MPV and the maximal velocity of the concentric phase (Vmax) were compared with a linear position transducer system during a standard bench press exercise. Participants performed a 1 repetition maximum test using the supine bench press exercise. The testing procedures involved the simultaneous assessment of bench press propulsive velocity using 2 kinematic (linear position transducer and semi-automated tracking software) systems. High Pearson's correlation coefficients for MPV and Vmax between both devices (r = 0.473 to 0.993) were observed. The intraclass correlation coefficients for barbell velocity data and the kinematic data obtained from video analysis were high (>0.79). In addition, the low coefficients of variation indicate that measurements had low variability. Finally, Bland-Altman plots with the limits of agreement of the MPV and Vmax with different loads showed a negative trend, which indicated that the video analysis had higher values than the linear transducer. In conclusion, this study has demonstrated that the software used for the video analysis was an easy to use and cost-effective tool with a very high degree of concurrent validity. This software can be used to evaluate changes in velocity of training load in resistance training, which may be important for the prescription and monitoring of training programmes.
Internal quality control in serological tests for syphilis.
Wasley, G D
1985-01-01
The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis. PMID:3884487
Pearson, Simon N; Cronin, John B; Hume, Patria A; Slyfield, David
2009-09-01
Understanding how loading affects power production in resistance training is a key step in identifying the most optimal way of training muscular power - an essential trait in most sporting movements. Twelve elite male sailors with extensive strength-training experience participated in a comparison of kinematics and kinetics from the upper body musculature, with upper body push (bench press) and pull (bench pull) movements performed across loads of 10-100% of one repetition maximum (1RM). 1RM strength and force were shown to be greater in the bench press, while velocity and power outputs were greater for the bench pull across the range of loads. While power output was at a similar level for the two movements at a low load (10% 1RM), significantly greater power outputs were observed for the bench pull in comparison to the bench press with increased load. Power output (Pmax) was maximized at higher relative loads for both mean and peak power in the bench pull (78.6 +/- 5.7% and 70.4 +/- 5.4% of 1RM) compared to the bench press (53.3 +/- 1.7% and 49.7 +/- 4.4% of 1RM). Findings can most likely be attributed to differences in muscle architecture, which may have training implications for these muscles.
Smart training environment for power electronics
NASA Astrophysics Data System (ADS)
Hinov, Nikolay; Hranov, Tsveti
2017-12-01
The idea of the paper is to present a successful symbiosis of the products of the leading firms in the electronics - National Instruments and Texas Instruments. The developed test bench is composed of hardware for data acquisition and control (sbRIO), working with the LabVIEW environment and the novel Power Management Lab Kit (PMLK) educational boards. The manipulation of these hi-tech boards becomes more accessible for a broader range of students, including undergraduates in schools, with the use of LabVIEW virtual instruments (VI), which assist the trainees in the manipulation of the kits - for example if a incompatible working configuration is set, the VI will pop up a message describing the result if its execution. Moreover it will provide guidance for choosing the right setup along the active decisions from the student and also with the VI can be taken measurements, without the need of external hardware.
García-Ramos, Amador; Haff, G Gregory; Padial, Paulino; Feriche, Belén
2018-03-01
This study aimed to examine the reliability of different power and velocity variables during the Smith machine bench press (BP) and bench press throw (BPT) exercises. Twenty-two healthy men conducted four testing sessions after a preliminary BP one-repetition maximum (1RM) test. In a counterbalanced order, participants performed two sessions of BP in one week and two sessions of BPT in another week. Mean propulsive power, peak power, mean propulsive velocity, and peak velocity at each tenth percentile (20-70% of 1RM) were recorded by a linear transducer. The within-participants coefficient of variation (CV) was higher for the load-power relationship compared to the load-velocity relationship in both the BP (5.3% vs. 4.1%; CV ratio = 1.29) and BPT (4.7% vs. 3.4%; CV ratio = 1.38). Mean propulsive variables showed lower reliability than peak variables in both the BP (5.4% vs. 4.0%, CV ratio = 1.35) and BPT (4.8% vs. 3.3%, CV ratio = 1.45). All variables were deemed reliable, with the peak velocity demonstrating the lowest within-participants CV. Based upon these findings, the peak velocity should be chosen for the accurate assessment of BP and BPT performance.
Systematic Studies for the Development of High-Intensity Abs
NASA Astrophysics Data System (ADS)
Barion, L.; Ciullo, G.; Contalbrigo, M.; Dalpiaz, P. F.; Lenisa, P.; Statera, M.
2011-01-01
The effect of the dissociator cooling temperature has been tested in order to explain the unexpected RHIC atomic beam intensity. Studies on trumpet nozzle geometry, compared to standard sonic nozzle have been performed, both with simulation methods and test bench measurements on molecular beams, obtaining promising results.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES SID-IIsD Side Impact Crash Test Dummy... impacted side removed. The dummy is equipped with a lower spine laterally oriented accelerometer as... side of the seated dummy tangent to a vertical plane located within 10 mm of the side edge of the bench...
9 CFR 71.21 - Tissue and blood testing at slaughter.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., taking into account whether APHIS will be conducting complete tests at the facility, or only collecting..., until after the post-mortem examination is completed; (4) Includes tables, benches, and other equipment on which sample collection and processing are to be performed, of such design, material, and...
Status of the PHOENIX electron cyclotron resonance charge breeder at ISOLDE, CERN.
Barton, Charles; Cederkall, Joakim; Delahaye, Pierre; Kester, Oliver; Lamy, Thierry; Marie-Jeanne, Mélanie
2008-02-01
We report here on the last progresses made with the PHOENIX electron cyclotron resonance charge breeder test bench at ISOLDE. Recently, an experiment was performed to test the trapping of (61)Fe daughter nuclides from the decay of (61)Mn nuclides. Preliminary results are given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melin, Alexander M.; Kisner, Roger A.; Drira, Anis
Embedded instrumentation and control systems that can operate in extreme environments are challenging due to restrictions on sensors and materials. As a part of the Department of Energy's Nuclear Energy Enabling Technology cross-cutting technology development programs Advanced Sensors and Instrumentation topic, this report details the design of a bench-scale embedded instrumentation and control testbed. The design goal of the bench-scale testbed is to build a re-configurable system that can rapidly deploy and test advanced control algorithms in a hardware in the loop setup. The bench-scale testbed will be designed as a fluid pump analog that uses active magnetic bearings tomore » support the shaft. The testbed represents an application that would improve the efficiency and performance of high temperature (700 C) pumps for liquid salt reactors that operate in an extreme environment and provide many engineering challenges that can be overcome with embedded instrumentation and control. This report will give details of the mechanical design, electromagnetic design, geometry optimization, power electronics design, and initial control system design.« less
Selenium Speciation and Management in Wet FGD Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Searcy, K; Richardson, M; Blythe, G
2012-02-29
This report discusses results from bench- and pilot-scale simulation tests conducted to determine the factors that impact selenium speciation and phase partitioning in wet FGD systems. The selenium chemistry in wet FGD systems is highly complex and not completely understood, thus extrapolation and scale-up of these results may be uncertain. Control of operating parameters and application of scrubber additives have successfully demonstrated the avoidance or decrease of selenite oxidation at the bench and pilot scale. Ongoing efforts to improve sample handling methods for selenium speciation measurements are also discussed. Bench-scale scrubber tests explored the impacts of oxidation air rate, tracemore » metals, scrubber additives, and natural limestone on selenium speciation in synthetic and field-generated full-scale FGD liquors. The presence and concentration of redox-active chemical species as well as the oxidation air rate contribute to the oxidation-reduction potential (ORP) conditions in FGD scrubbers. Selenite oxidation to the undesirable selenate form increases with increasing ORP conditions, and decreases with decreasing ORP conditions. Solid-phase manganese [Mn(IV)] appeared to be the significant metal impacting the oxidation of selenite to selenate. Scrubber additives were tested for their ability to inhibit selenite oxidation. Although dibasic acid and other scrubber additives showed promise in early clear liquor (sodium based and without calcium solids) bench-scale tests, these additives did not show strong inhibition of selenite oxidation in tests with higher manganese concentrations and with slurries from full-scale wet FGD systems. In bench-tests with field liquors, addition of ferric chloride at a 250:1 iron-to-selenium mass ratio sorbed all incoming selenite to the solid phase, although addition of ferric salts had no impact on native selenate that already existed in the field slurry liquor sample. As ORP increases, selenite may oxidize to selenate more rapidly than it sorbs to ferric solids. Though it was not possible to demonstrate a decrease in selenium concentrations to levels below the project'ale testing were evident at the pilot scale. Specifically, reducing oxidation air rate and ORP tends to either retain selenium as selenite in the liquor or shift selenium phase partitioning to the solid phase. Oxidation air flow rate control may be one option for managing selenium behavior in FGD scrubbers. Units that cycle load widely may find it more difficult to impact ORP conditions with oxidation air flow rate control alone. Because decreasing oxidation air rates to the reaction tank showed that all new selenium reported to the solids, the addition of ferric chloride to the pilot scrubber could not show further improvements in selenium behavior. Ferric chloride addition did shift mercury to the slurry solids, specifically to the fine particles. Several competing pathways may govern the reporting of selenium to the slurry solids: co-precipitation with gypsum into the bulk solids and sorption or co-precipitation with iron into the fine particles. Simultaneous measurement of selenium and mercury behavior suggests a holistic management strategy is best to optimize the fate of both of these elements in FGD waters. Work conducted under this project evaluated sample handling and analytical methods for selenium speciation in FGD waters. Three analytical techniques and several preservation methods were employed. Measurements of selenium speciation over time indicated that for accurate selenium speciation, it is best to conduct measurements on unpreserved, filtered samples as soon after sampling as possible. The capital and operating costs for two selenium management strategies were considered: ferric chloride addition and oxidation air flow rate control. For ferric chloride addition, as might be expected the reagent makeup costs dominate the overall costs, and range from 0.22 to 0.29 mills/kWh. For oxidation air flow rate control, a cursory comparison of capital costs and turndown capabilities for multi-stage and single-stage centrifugal blowers and several flow control methods was completed. For greenfield systems, changing the selection of blower type and flow control method may have payback periods of 4 to 5 years or more if based on energy savings alone. However, the benefits to managing redox chemistry in the scrubber could far outweigh the savings in electricity costs under some circumstances.« less
Competing Discourses of Scientific Identity among Postdoctoral Scholars in the Biomedical Sciences.
Price, Rebecca M; Kantrowitz-Gordon, Ira; Gordon, Sharona E
2018-06-01
The postdoctoral period is generally one of low pay, long hours, and uncertainty about future career options. To better understand how postdocs conceive of their present and future goals, we asked researchers about their scientific identities while they were in their postdoctoral appointments. We used discourse analysis to analyze interviews with 30 scholars from a research-intensive university or nearby research institutions to better understand how their scientific identities influenced their career goals. We identified two primary discourses: bench scientist and principal investigator (PI). The bench scientist discourse is characterized by implementing other people's scientific visions through work in the laboratory and expertise in experimental design and troubleshooting. The PI discourse is characterized by a focus on formulating scientific visions, obtaining funding, and disseminating results through publishing papers and at invited talks. Because these discourses represent beliefs, they can-and do-limit postdocs' understandings of what career opportunities exist and the transferability of skills to different careers. Understanding the bench scientist and PI discourses, and how they interact, is essential for developing and implementing better professional development programs for postdocs.
NASA Technical Reports Server (NTRS)
Turner, Travis L.; Kidd, Reggie T.; Hartl, Darren J.; Scholten, William D.
2013-01-01
Airframe noise is a significant part of the overall noise produced by typical, transport-class aircraft during the approach and landing phases of flight. Leading-edge slat noise is a prominent source of airframe noise. The concept of a slat-cove filler was proposed in previous work as an effective means of mitigating slat noise. Bench-top models were deployed at 75% scale to study the feasibility of producing a functioning slat-cove filler. Initial results from several concepts led to a more-focused effort investigating a deformable structure based upon pseudoelastic SMA materials. The structure stows in the cavity between the slat and main wing during cruise and deploys simultaneously with the slat to guide the aerodynamic flow suitably for low noise. A qualitative parametric study of SMA-enabled, slat-cove filler designs was performed on the bench-top. Computational models were developed and analyses were performed to assess the displacement response under representative aerodynamic load. The bench-top and computational results provide significant insight into design trades and an optimal design.
Kunkle, Gerald A.
2016-01-07
The Sutron 8310-N-S (8310) data collection platform (DCP) manufactured by Sutron Corporation was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to the manufacturer’s specifications for recording and transmitting data. The 8310-N-S is a National Electrical Manufacturers Association (NEMA)-enclosed DCP with a built-in Geostationary Operational Environmental Satellite transmitter that operates over a temperature range of −40 to 60 degrees Celsius (°C). The evaluation procedures followed and the results obtained are described in this report for bench, temperature chamber, and outdoor deployment testing. The three units tested met the manufacturer’s stated specifications for the tested conditions, but two of the units had transmission errors either during temperature chamber or deployment testing. During outdoor deployment testing, 6.72 percent of transmissions by serial number 1206109 contained errors, resulting in missing data. Transmission errors were also observed during temperature chamber testing with serial number 1208283, at an error rate of 3.22 percent. Overall, the 8310 has good logging capabilities, but the transmission errors are a concern for users who require reliable telemetered data.
Testing the pyramid truth wavefront sensor for NFIRAOS in the lab
NASA Astrophysics Data System (ADS)
Mieda, Etsuko; Rosensteiner, Matthias; van Kooten, Maaike; Veran, Jean-Pierre; Lardiere, Olivier; Herriot, Glen
2016-07-01
For today and future adaptive optics observations, sodium laser guide stars (LGSs) are crucial; however, the LGS elongation problem due to the sodium layer has to be compensated, in particular for extremely large telescopes. In this paper, we describe the concept of truth wavefront sensing as a solution and present its design using a pyramid wavefront sensor (PWFS) to improve NFIRAOS (Narrow Field InfraRed Adaptive Optics System), the first light adaptive optics system for Thirty Meter Telescope. We simulate and test the truth wavefront sensor function under a controlled environment using the HeNOS (Herzberg NFIRAOS Optical Simulator) bench, a scaled-down NFIRAOS bench at NRC-Herzberg. We also touch on alternative pyramid component options because despite recent high demands for PWFSs, we suffer from the lack of pyramid supplies due to engineering difficulties.
Atmospheric simulation using a liquid crystal wavefront-controlling device
NASA Astrophysics Data System (ADS)
Brooks, Matthew R.; Goda, Matthew E.
2004-10-01
Test and evaluation of laser warning devices is important due to the increased use of laser devices in aerial applications. This research consists of an atmospheric aberrating system to enable in-lab testing of various detectors and sensors. This system employs laser light at 632.8nm from a Helium-Neon source and a spatial light modulator (SLM) to cause phase changes using a birefringent liquid crystal material. Measuring outgoing radiation from the SLM using a CCD targetboard and Shack-Hartmann wavefront sensor reveals an acceptable resemblance of system output to expected atmospheric theory. Over three turbulence scenarios, an error analysis reveals that turbulence data matches theory. A wave optics computer simulation is created analogous to the lab-bench design. Phase data, intensity data, and a computer simulation affirm lab-bench results so that the aberrating SLM system can be operated confidently.
Hands-on Simulation versus Traditional Video-learning in Teaching Microsurgery Technique
SAKAMOTO, Yusuke; OKAMOTO, Sho; SHIMIZU, Kenzo; ARAKI, Yoshio; HIRAKAWA, Akihiro; WAKABAYASHI, Toshihiko
2017-01-01
Bench model hands-on learning may be more effective than traditional didactic practice in some surgical fields. However, this has not been reported for microsurgery. Our study objective was to demonstrate the efficacy of bench model hands-on learning in acquiring microsuturing skills. The secondary objective was to evaluate the aptitude for microsurgery based on personality assessment. Eighty-six medical students comprising 62 men and 24 women were randomly assigned to either 20 min of hands-on learning with a bench model simulator or 20 min of video-learning using an instructional video. They then practiced microsuturing for 40 min. Each student then made three knots, and the time to complete the task was recorded. The final products were scored by two independent graders in a blind fashion. All participants then took a personality test, and their microsuture test scores and the time to complete the task were compared. The time to complete the task was significantly shorter in the simulator group than in the video-learning group. The final product scores tended to be higher with simulator-learning than with video-learning, but the difference was not significant. Students with high “extraversion” scores on the personality inventory took a shorter time to complete the suturing test. Simulator-learning was more effective for microsurgery training than video instruction, especially in understanding the procedure. There was a weak association between personality traits and microsurgery skill. PMID:28381653
Advanced direct coal liquefaction concepts. Quarterly report, April 1, 1993--June 30, 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, D.J.; Parker, R.J.; Simpson, P.L.
Construction and commissioning of the bench unit for operation of the first stage of the process was completed. Solubilization of Black Thunder coal using carbon monoxide and steam was successfully demonstrated in the counterflow reactor system. The results were comparable with those obtained in the autoclave with the exception that coal solubilization at the same nominal residence times was slightly lower. The bench unit has now been modified for two stage operation. The Wilsonville process derived solvent for Black Thunder coal (V-1074) was found to be essentially as stable as the previous solvent used in the autoclave runs (V-178 +more » 320) at reactor conditions. This solvent (V-1074) is, therefore, being used in the bench unit tests. Carbon monoxide may be replaced by synthesis gas for the coal solubilization step in the process. However, in autoclave tests, coal conversion was found to be dependent on the amount of carbon monoxide present in the synthesis gas. Coal conversions ranged from 88% for pure carbon monoxide to 67% for a 25:75 carbon monoxide/hydrogen mixture at equivalent conditions. Two stage liquefaction tests were completed in the autoclave using a disposable catalyst (FeS) and hydrogen in the second stage. Increased coal conversion, higher gas and oil and lower asphaltene and preasphaltene yields were observed as expected. However, no hydrogen consumption was observed in the second stage. Other conditions, in particular, alternate catalyst systems will be explored.« less
NASA Astrophysics Data System (ADS)
Boubenia, R.; Rosenkrantz, E.; Despetis, F.; P, P.; Ferrandis, J.-Y.
2016-03-01
Our team is specialized in ultrasonic measurements in hostile environment especially under high temperatures. There is a need for acoustic transducers capable of continuous measurement at temperatures up to 700°C. To improve the performances of acoustic sensors we focus our works on the realisation and characterisation of transducer backings able to operate under very high temperature. Commercially, they are produced by the incorporation of tungsten powder in a plastic matrix, which limits the working temperature. The realisation of ultrasonic transducers for non-destructive measures at high temperatures requires adequate materials, manufacturing and assembly processes. To produce the backings, composites were made using very ductile metals such as tin and tungsten. These composites are manufactured by uniaxial hot pressing. First, we studied the influence of temperature and pressure on the densification of tin pellets. Then, several specimens made of tin/W were made and characterised by measuring the specific weight, speed and attenuation of sound. The acoustic measures were realised by ultrasonic spectroscopy. This test-bench was designed and tested on control samples of PMMA and on standard backings (epoxy / tungsten).
Development of a Pyramid Wave-front Sensor
NASA Astrophysics Data System (ADS)
El Hadi, Kacem; Vignaux, Mael; Fusco, Thierry
2013-12-01
Within the framework of the E-ELT studies, several laboratories are involved on some instruments: HARMONY with its ATLAS adaptive optics [AO] system, EAGLE or EPICS. Most of the AO systems will probably integrate one or several pyramidal wavefront sensors, PWFS (R. Ragazzoni [1]). The coupling in an AO loop and the control in laboratory (then on sky) of this type of sensor is fundamental for the continuation of the projects related to OA systems on the E-ELT. LAM (Laboratory of Astrophysics of Marseille) is involved in particular in the VLT-SPHERE, ATLAS, EPICS projects. For the last few years, our laboratory has been carrying out different R&D activities in AO instrumentation for ELTs. An experimental AO bench is designed and being developed to allow the validation of new wave-front sensing and control concepts [2]. One the objectives of this bench, is the experimental validation of a pyramid WFS. Theoretical investigations on its behavior have been already made. The world's fastest and most sensitive camera system (OCAM2) has been recently developed at LAM (J.L Gach [3], First Light Imaging). Conjugating this advantage with the pyramid concept, we plan to demonstrate a home made Pyramid sensor for Adaptive Optics whose the speed and the precision are the key points. As a joint collaboration with ONERA and Shaktiware, our work aims at the optimization (measurement process, calibration and operation) in laboratory then on the sky of a pyramid sensor dedicated to the first generation instruments for ELTs. The sensor will be implemented on the ONERA ODISSEE AO bench combining thus a pyramid and a Shack-Hartmann wavefront sensors. What would give the possibility to compare strictly these two WFS types and make this bench unique in France and even in Europe. Experimental work on laboratory demonstration is undergoing. The status of our development will presented at the conference.
100. COBBLER SHOP AFT LOOKING FORWARD VISIBLE ARE ...
100. COBBLER SHOP - AFT LOOKING FORWARD - VISIBLE ARE THE FINISHING MACHINE, DAVIS STITCHING MACHINE, SINGER SEWING MACHINE FROM TAILOR SHOP, STORAGE SHELVES, WORK BENCH AND SHOE TREE STAND. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA
Water electrolysis system refurbishment and testing
NASA Technical Reports Server (NTRS)
Greenough, B. M.
1972-01-01
The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemaire, R., E-mail: romain.lemaire@mines-douai.fr; Menanteau, S.
2016-01-15
This paper deals with the thorough characterization of a new experimental test bench designed to study the devolatilization and oxidation of pulverized fuel particles in a wide range of operating conditions. This lab-scale facility is composed of a fuel feeding system, the functioning of which has been optimized by computational fluid dynamics. It allows delivering a constant and time-independent mass flow rate of fuel particles which are pneumatically transported to the central injector of a hybrid McKenna burner using a carrier gas stream that can be inert or oxidant depending on the targeted application. A premixed propane/air laminar flat flamemore » stabilized on the porous part of the burner is used to generate the hot gases insuring the heating of the central coal/carrier-gas jet with a thermal gradient similar to those found in industrial combustors (>10{sup 5} K/s). In the present work, results issued from numerical simulations performed a priori to characterize the velocity and temperature fields in the reaction chamber have been analyzed and confronted with experimental measurements carried out by coupling particle image velocimetry, thermocouple and two-color pyrometry measurements so as to validate the order of magnitude of the heating rate delivered by such a new test bench. Finally, the main features of the flat flame reactor we developed have been discussed with respect to those of another laboratory-scale system designed to study coal devolatilization at a high heating rate.« less
NASA Astrophysics Data System (ADS)
Lemaire, R.; Menanteau, S.
2016-01-01
This paper deals with the thorough characterization of a new experimental test bench designed to study the devolatilization and oxidation of pulverized fuel particles in a wide range of operating conditions. This lab-scale facility is composed of a fuel feeding system, the functioning of which has been optimized by computational fluid dynamics. It allows delivering a constant and time-independent mass flow rate of fuel particles which are pneumatically transported to the central injector of a hybrid McKenna burner using a carrier gas stream that can be inert or oxidant depending on the targeted application. A premixed propane/air laminar flat flame stabilized on the porous part of the burner is used to generate the hot gases insuring the heating of the central coal/carrier-gas jet with a thermal gradient similar to those found in industrial combustors (>105 K/s). In the present work, results issued from numerical simulations performed a priori to characterize the velocity and temperature fields in the reaction chamber have been analyzed and confronted with experimental measurements carried out by coupling particle image velocimetry, thermocouple and two-color pyrometry measurements so as to validate the order of magnitude of the heating rate delivered by such a new test bench. Finally, the main features of the flat flame reactor we developed have been discussed with respect to those of another laboratory-scale system designed to study coal devolatilization at a high heating rate.
Cionni, Robert J.; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-01-01
Purpose To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. Methods This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Results Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. Conclusions The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. Translational Relevance This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery. PMID:26290778
NASA Astrophysics Data System (ADS)
Barone, F.; Giordano, G.; Acernese, F.; Romano, R.
2018-03-01
In this paper, we present some innovative and general strategies for the control of benches and platforms, that the introduction of the new class of monolithic UNISA Folded Pendulum is now making it possible, also in terms of environmental conditions, like ultra-high-vacuum (UHV), cryogenics and harsh environments. In particular, we present and discuss a parametric analysis of the control models in connection with the sensors limitations in terms of sensitivity and band. Finally, we present and discuss some experimental laboratory tests on a laboratory platform, underlining the present advantages and the expected future improvements.
Ranky, Richard G; Sivak, Mark L; Lewis, Jeffrey A; Gade, Venkata K; Deutsch, Judith E; Mavroidis, Constantinos
2014-06-05
Cycling has been used in the rehabilitation of individuals with both chronic and post-surgical conditions. Among the challenges with implementing bicycling for rehabilitation is the recruitment of both extremities, in particular when one is weaker or less coordinated. Feedback embedded in virtual reality (VR) augmented cycling may serve to address the requirement for efficacious cycling; specifically recruitment of both extremities and exercising at a high intensity. In this paper a mechatronic rehabilitation bicycling system with an interactive virtual environment, called Virtual Reality Augmented Cycling Kit (VRACK), is presented. Novel hardware components embedded with sensors were implemented on a stationary exercise bicycle to monitor physiological and biomechanical parameters of participants while immersing them in an augmented reality simulation providing the user with visual, auditory and haptic feedback. This modular and adaptable system attaches to commercially-available stationary bicycle systems and interfaces with a personal computer for simulation and data acquisition processes. The complete bicycle system includes: a) handle bars based on hydraulic pressure sensors; b) pedals that monitor pedal kinematics with an inertial measurement unit (IMU) and forces on the pedals while providing vibratory feedback; c) off the shelf electronics to monitor heart rate and d) customized software for rehabilitation. Bench testing for the handle and pedal systems is presented for calibration of the sensors detecting force and angle. The modular mechatronic kit for exercise bicycles was tested in bench testing and human tests. Bench tests performed on the sensorized handle bars and the instrumented pedals validated the measurement accuracy of these components. Rider tests with the VRACK system focused on the pedal system and successfully monitored kinetic and kinematic parameters of the rider's lower extremities. The VRACK system, a virtual reality mechatronic bicycle rehabilitation modular system was designed to convert most bicycles in virtual reality (VR) cycles. Preliminary testing of the augmented reality bicycle system was successful in demonstrating that a modular mechatronic kit can monitor and record kinetic and kinematic parameters of several riders.
Plans of Mice and Men: From Bench Science to Science Policy
Simon, Ian D.
2011-01-01
The transition from bench science to science policy is not always a smooth one, and my journey stretched as far as the unemployment line to the hallowed halls of the U.S. Capitol. While earning my doctorate in microbiology, I found myself more interested in my political activities than my experiments. Thus, my science policy career aspirations were born from merging my love of science with my interest in policy and politics. After receiving my doctorate, I accepted the Henry Luce Scholarship, which allowed me to live in South Korea for 1 year and delve into the field of science policy research. This introduction into science policy occurred at the South Korean think tank called the Science and Technology Policy Institute (STEPI). During that year, I used textbooks, colleagues, and hands-on research projects as my educational introduction into the social science of science and technology decision-making. However, upon returning to the United States during one of the worst job markets in nearly 80 years, securing a position in science policy proved to be very difficult, and I was unemployed for five months. Ultimately, it took more than a year from the end of the Luce Scholarship to obtain my next science policy position with the American Society for Microbiology Congressional Fellowship. This fellowship gave me the opportunity to work as the science and public health advisor to U.S. Senator Harry Reid. While there were significant challenges during my transition from the laboratory to science policy, those challenges made me tougher, more appreciative, and more prepared to move from working at the bench to working in the field of science policy. PMID:21966041
Plans of mice and men: from bench science to science policy.
Simon, Ian D
2011-09-01
The transition from bench science to science policy is not always a smooth one, and my journey stretched as far as the unemployment line to the hallowed halls of the U.S. Capitol. While earning my doctorate in microbiology, I found myself more interested in my political activities than my experiments. Thus, my science policy career aspirations were born from merging my love of science with my interest in policy and politics. After receiving my doctorate, I accepted the Henry Luce Scholarship, which allowed me to live in South Korea for 1 year and delve into the field of science policy research. This introduction into science policy occurred at the South Korean think tank called the Science and Technology Policy Institute (STEPI). During that year, I used textbooks, colleagues, and hands-on research projects as my educational introduction into the social science of science and technology decision-making. However, upon returning to the United States during one of the worst job markets in nearly 80 years, securing a position in science policy proved to be very difficult, and I was unemployed for five months. Ultimately, it took more than a year from the end of the Luce Scholarship to obtain my next science policy position with the American Society for Microbiology Congressional Fellowship. This fellowship gave me the opportunity to work as the science and public health advisor to U.S. Senator Harry Reid. While there were significant challenges during my transition from the laboratory to science policy, those challenges made me tougher, more appreciative, and more prepared to move from working at the bench to working in the field of science policy. Copyright © 2011.
Catalytic Hydrogenation of Bio-Oil for Chemicals and Fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, Douglas C.
2006-02-14
The scope of work includes optimizing processing conditions and demonstrating catalyst lifetime for catalyst formulations that are readily scaleable to commercial operations. We use a bench-scale, continuous-flow, packed-bed, catalytic, tubular reactor, which can be operated in the range of 100-400 mL/hr., from 50-400 C and up to 20MPa (see Figure 1). With this unit we produce upgraded bio-oil from whole bio-oil or useful bio-oil fractions, specifically pyrolytic lignin. The product oils are fractionated, for example by distillation, for recovery of chemical product streams. Other products from our tests have been used in further testing in petroleum refining technology at UOPmore » and fractionation for product recovery in our own lab. Further scale-up of the technology is envisioned and we will carry out or support process design efforts with industrial partners, such as UOP.« less
Water vapor diffusion membrane development
NASA Technical Reports Server (NTRS)
Tan, M. K.
1977-01-01
An application of the water vapor diffusion technique is examined whereby the permeated water vapor is vented to space vacuum to alleviate on-board waste storage and provide supplemental cooling. The work reported herein deals primarily with the vapor diffusion-heat rejection (VD-HR) as it applies to the Space Shuttle. A stack configuration was selected, designed and fabricated. An asymmetric cellulose acetate membrane, used in reverse osmosis application was selected and a special spacer was designed to enhance mixing and promote mass transfer. A skid-mount unit was assembled from components used in the bench unit although no attempt was made to render it flight-suitable. The operating conditions of the VD-HR were examined and defined and a 60-day continuous test was carried out. The membranes performed very well throughout the test; no membrane rupture and no unusual flux decay was observed. In addition, a tentative design for a flight-suitable VD-HR unit was made.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, Richard; Heinrichs, Michael; Argumedo, Darwin
Objectives: Through this grant, Battelle proposes to address Area of Interest (AOI) 1 to develop a bench-scale technology to economically separate, extract, and concentrate mixed REEs from coal ash. U.S. coal and coal byproducts provide the opportunity for a domestic source of REEs. The DOE’s National Energy Technology Laboratory (NETL) has characterized various coal and coal byproducts samples and has found varying concentrations of REE ranging up to 1,000 parts per million by weight. The primary project objective is to validate the economic viability of recovering REEs from the coal byproduct coal ash using Battelle’s patented closed-loop Acid Digestion Processmore » (ADP). This will be accomplished by selecting coal sources with the potential to provide REE concentrations above 300 parts per million by weight, collecting characterization data for coal ash samples generated via three different methods, and performing a Techno-Economic Analysis (TEA) for the proposed process. The regional availability of REE-laden coal ash, the regional market for rare earth concentrates, and the system capital and operating costs for rare earth recovery using the ADP technology will be accounted for in the TEA. Limited laboratory testing will be conducted to generate the parameters needed for the design of a bench scale system for REE recovery. The ultimate project outcome will be the design for an optimized, closed loop process to economically recovery REEs such that the process may be demonstrated at the bench scale in a Phase 2 project. Project Description: The project will encompass evaluation of the ADP technology for the economic recovery of REEs from coal and coal ash. The ADP was originally designed and demonstrated for the U.S. Army to facilitate demilitarization of cast-cured munitions via acid digestion in a closed-loop process. Proof of concept testing has been conducted on a sample of Ohio-based Middle Kittanning coal and has demonstrated the feasibility of recovering REEs using the ADP technology. In AOI 1, Ohio coal sources with the potential to provide a consistent source of rare earth element concentrations above 300 parts per million will be identified. Coal sample inventories from West Virginia and Pennsylvania will also be assessed for purposes of comparison. Three methods of preparing the coal ash will be evaluated for their potential to enhance the technical feasibility and economics of REE recovery. Three sources of coal ash are targeted for evaluation of the economics of REE recovery in this project: (1) coal ash from power generation stations, to include fly ash and/or bottom ash, (2) ash generated in a lower temperature ashing process, and (3) ash residual from Battelle’s coal liquefaction process. Making use of residual ash from coal liquefaction processes directly leverages work currently being conducted by Battelle for DOE NETL in response to DE-FOA-0000981 entitled “Greenhouse Gas Emissions Reductions Research and Development Leading to Cost-Competitive Coal-to-Liquids Based Jet Fuel Production.” Using the sample characterization results and regional information regarding REE concentration, availability and cost, a TEA will be developed. The previously generated laboratory testing results for leaching and REE recovery via the ADP will be used to perform the TEA, along with common engineering assumptions for scale up of equipment and labor costs. Finally, upon validation of the economic feasibility of the process by the TEA, limited laboratory testing will be performed to support the design of a bench scale system. In a future project phase, it is envisioned that the bench scale system will be constructed and operated to prove the process on a continuous basis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marrone, Philip A.; Elliott, Douglas C.; Billing, Justin M.
Hydrothermal Liquefaction (HTL) and Catalytic Hydrothermal Gasification (CHG) proof-of-concept bench-scale tests were performed to assess the potential of hydrothermal treatment for handling municipal wastewater sludge. HTL tests were conducted at 300-350°C and 20 MPa on three different feeds: primary sludge, secondary sludge, and digested solids. Corresponding CHG tests were conducted at 350°C and 20 MPa on the HTL aqueous phase output using a ruthenium based catalyst. Biocrude yields ranged from 25-37%. Biocrude composition and quality were comparable to biocrudes generated from algae feeds. Subsequent hydrotreating of biocrude resulted in a product with comparable physical and chemical properties to crude oil.more » CHG product gas methane yields on a carbon basis ranged from 47-64%. Siloxane concentrations in the CHG product gas were below engine limits. The HTL-CHG process resulted in a chemical oxygen demand (COD) reduction of > 99.9% and a reduction in residual solids for disposal of 94-99%.« less
Visualization of fluid turbulence and acoustic cavitation during phacoemulsification.
Tognetto, Daniele; Sanguinetti, Giorgia; Sirotti, Paolo; Brezar, Edoardo; Ravalico, Giuseppe
2005-02-01
To describe a technique for visualizing fluid turbulence and cavitational energy created by ultrasonic phaco tips. University Eye Clinic of Trieste, Trieste, Italy. Generation of cavitational energy by the phaco tip was visualized using an optical test bench comprising several components. The technique uses a telescope system to expand a laser light source into a coherent, collimated beam of light with a diameter of approximately 50.0 mm. The expanded laser beam shines on the test tube containing the tip activated in a medium of water or ophthalmic viscosurgical device (OVD). Two precision optical collimators complete the optical test bench and form the system used to focus data onto a charge-coupled device television camera connected to a recorder. Images of irrigation, irrigation combined with aspiration, irrigation/aspiration, and phacosonication were obtained with the tip immersed in a tube containing water or OVD. Optical image processing enabled acoustic cavitation to be visualized during phacosonication. The system is a possible means of evaluating a single phaco apparatus power setting and comparing phaco machines and techniques.
Test Bench for Coupling and Shielding Magnetic Fields
NASA Astrophysics Data System (ADS)
Jordan, J.; Esteve, V.; Dede, E.; Sanchis, E.; Maset, E.; Ferreres, A.; Ejea, J. B.; Cases, C.
2016-05-01
This paper describes a test bench for training purposes, which uses a magnetic field generator to couple this magnetic field to a victim circuit. It can be very useful to test for magnetic susceptibility as well. The magnetic field generator consists of a board, which generates a variable current that flows into a printed circuit board with spiral tracks (noise generator). The victim circuit consists of a coaxial cable concentric with the spiral tracks and its generated magnetic field. The coaxial cable is part of a circuit which conducts a signal produced by a signal generator and a resistive load. In the paper three cases are studied. First, the transmitted signal from the signal generator uses the central conductor of the coaxial cable and the shield is floating. Second, the shield is short circuited at its ends (and thus forming a loop). Third, when connecting the shield in series with the inner conductor and therefore having the current flowing into the coax via the inner conductor and returning via the shield.
Physical fitness and job performance of firefighters.
Rhea, Matthew R; Alvar, Brent A; Gray, Rayne
2004-05-01
Accurate correlations between a wide range of physical fitness measures and occupational demands are needed in order to identify specific fitness tests and training needs for firefighters. Twenty professional firefighters performed numerous fitness and job-related performance tests. Pearson product moment correlations were performed to identify the relationship between fitness components and job performance. Significant correlations (p <0.05) with job performance were identified for total fitness (r = -0.62), bench press strength (r = -0.66), hand grip strength (r = -0.71), bent-over row endurance (r = -0.61), bench press endurance (r = -0.73), shoulder press endurance (r = -0.71), bicep endurance (r = -0.69), squat endurance (r = -0.47), and 400-m sprint time (r = 0.79). It is apparent that firefighting taxes virtually all aspects of physical fitness. These data can help the exercise specialist choose appropriate tests and prescribe specific fitness programs for firefighters. Traditional firefighter exercise programs focusing mainly on cardiovascular fitness should be replaced with physical conditioning programs that address all components of fitness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnhill, William C.; Gao, Hong; Kheireddin, Bassem
We have previously reported an oil-miscible phosphonium-organophosphate ionic liquid (IL) with an effective anti-wear (AW) functionality when added to a base oil by itself or combined with a conventional zinc dialkyldithiophosphate (ZDDP) for a synergistic effect. In this research, we investigated whether this synergy manifests in formulated engine oils. An experimental SAE 0W-16 engine oil was generated containing a combination of IL and ZDDP with equal phosphorus contribution. The prototype engine oil was first evaluated using tribological bench tests: AW performance in boundary lubrication (BL) and friction behavior (Stribeck curves) in elastohydrodynamic, mixed, and BL. In addition, the forthcoming standardmore » Sequence VIE engine dynamometer test was then conducted to demonstrate improved fuel economy. Results were benchmarked against those of another experimental engine oil with almost the same formulation except using ZDDP only without the IL (similar total phosphorus content). The IL-ZDDP formulation consistently outperforms the ZDDP-only formulation in friction reduction and wear protection, and results from the bench and engine tests are well correlated.« less
Accuracy improvement in a calibration test bench for accelerometers by a vision system
DOE Office of Scientific and Technical Information (OSTI.GOV)
D’Emilia, Giulio, E-mail: giulio.demilia@univaq.it; Di Gasbarro, David, E-mail: david.digasbarro@graduate.univaq.it; Gaspari, Antonella, E-mail: antonella.gaspari@graduate.univaq.it
2016-06-28
A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behaviormore » if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.« less
Experimental verification of numerical calculations of railway passenger seats
NASA Astrophysics Data System (ADS)
Ligaj, B.; Wirwicki, M.; Karolewska, K.; Jasińska, A.
2018-04-01
The construction of railway seats is based on industry regulations and the requirements of end users, i.e. passengers. The two main documents in this context are the UIC 566 (3rd Edition, dated 7 January 1994) and the EN 12663-1: 2010+A1:2014. The study was to carry out static load tests of passenger seat frames. The paper presents the construction of the test bench and the results of experimental and numerical studies of passenger seat rail frames. The test bench consists of a frame, a transverse beam, two electric cylinders with a force value of 6 kN, and a strain gauge amplifier. It has a modular structure that allows for its expansion depending on the structure of the seats. Comparing experimental results with numerical results for points A and B allowed to determine the existing differences. It follows from it that higher stress values are obtained by numerical calculations in the range of 0.2 MPa to 35.9 MPa.
Composition and Structure of Mauna Loa's Submarine West Flank, Hawaii
NASA Astrophysics Data System (ADS)
Borchers, D.; Morgan, J. K.; Clague, D. A.; Moore, G. F.
2003-12-01
James Moore's pioneering work on submarine landslides in the Hawaiian Islands contributed significantly to early models for the structure and evolution of Mauna Loa's submarine western flank. The west flank experienced catastrophic failure in the past, generating massive blocks and debris fields offshore. Moore recognized that the midslope bench near the base of the submarine flank must have postdated the debris avalanche, but little data existed to determine if it formed in response to further landsliding or to deeper volcanic processes. As the processes that shaped Mauna Loa are thought to be analogous to those currently active at Kilauea, an improved understanding of Mauna Loa's history can provide valuable insight into the future of the younger Hawaiian volcanoes. Several recent marine surveys in the area, including submersible surveys conducted by MBARI and JAMSTEC, and a multi-channel seismic (MCS) survey carried out by the University of Hawaii, provide important new data about the composition and structure of Mauna Loa's submarine west flank. We carried out detailed geochemical, petrographic and structural analyses of rock samples and dive videos collected from the exposed northern wall of the midslope bench, documenting a repeated sequences of volcaniclastic sandstones and breccias. This stratigraphy contrasts with the predominantly subaerially erupted basalts composing the upper flank. Several thick ponded flows or sill-like diabase units are also interspersed in the section. The volcaniclastic units are highly cemented, and many contain hydrothermal alteration products, including chlorite, zeolites, and actinolite. The most altered rocks occur near the base of the bench and the degree of alteration decreases upward in the section. Samples collected from the outer scarp of the bench show evidence for intense shearing and cataclasis at all scales. The new MCS line crosses Mauna Loa's southern submarine flank and central bench. More than 500 m of finely layered slope strata overlie the upper flank to the south, and are truncated above the Ka Lae avalanche scar. The central bench to the north, sampled by the MBARI dives, shows only thin sediment cover above a poorly reflective interior. Strong deep reflections in both locations begin to resolve the underlying oceanic crust, as well as probable fault planes that may be responsible for flank deformation in this area. The abundance of volcaniclastic rocks with Mauna Loa affinities within the bench supports the idea that giant landslides from Mauna Loa were the source of much of the offshore debris. The stratal repetition, deformation fabrics, and cementation of the volcaniclastics also suggest that the rocks composing the bench were once deeply buried and have been subsequently exhumed by thrusting, most likely driven by deep volcanic spreading.
The Danish Environmental Technology Verification program (DANETV) Water Test Centre operated by DHI, is supported by the Danish Ministry for Science, Technology and Innovation. DANETV, the United States Environmental Protection Agency Environmental Technology Verification Progra...
Letter report on PCT/Monolith glass ceramic corrosion tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, Charles L.
2015-09-24
The Savannah River National Laboratory (SRNL) is collaborating with personnel from Pacific Northwest National Laboratory (PNNL) to study advanced waste form glass ceramics for immobilization of waste from Used Nuclear Fuel (UNF) separations processes. The glass ceramic waste forms take advantage of both crystalline and glassy phases where ‘troublesome’ elements (e.g., low solubility in glass or very long-lived) partition to highly durable ceramic phases with the remainder of elements residing in the glassy phase. The ceramic phases are tailored to create certain minerals or unique crystalline structures that can host the radionuclides by binding them in their specific crystalline networkmore » while not adversely impacting the residual glass network (Crum et al., 2011). Glass ceramics have been demonstrated using a scaled melter test performed in a pilot scale (1/4 scale) cold crucible induction melter (CCIM) (Crum et al., 2014; Maio et al., 2015). This report summarizes recent results from both Phase I and Phase II bench scale tests involving crucible fabrication and corrosion testing of glass ceramics using the Product Consistency Test (PCT). Preliminary results from both Phase I and Phase II bench scale tests involving statistically designed matrices have previously been reported (Crawford, 2013; Crawford, 2014).« less
The influence of somatotype on anaerobic performance
Faulkner, James; Jobson, Simon
2018-01-01
The link between athlete physique and performance in sports is well established. However, a direct link between somatotype three-numeral rating and anaerobic performance has not yet been reported. The purpose of this study was to assess the relations between somatotype and anaerobic performance using both singular and multivariate analyses. Thirty-six physically active males (mean ± standard deviation age 26.0 ± 9.8 years; body mass 79.5 ± 12.9 kg; height 1.82 ± 0.07 m) were somatotype-rated using the Heath-Carter method. Subjects were assessed for 3 repetition maximum (3 RM) bench press and back squat, and completed a 30-second maximal sprint cycle test. Positive correlations were observed between mesomorphy and 3 RM bench press (r = 0.560, p < 0.001), mesomorphy and 3 RM back squat (r = 0.550, p = 0.001) and between mesomorphy and minimum power output (r = 0.357, p = 0.033). Negative correlations were observed between ectomorphy and 3 RM bench press (r = -0.381, p = 0.022), and ectomorphy and 3 RM back squat (r = -0.336, p = 0.045). Individual regression analysis indicated that mesomorphy was the best predictor of 3 RM bench press performance, with 31.4% of variance in 3 RM bench press performance accounted for by the mesomorphy rating (p < 0.001). A combination of mesomorphy and ectomorphy best predicted 3 RM back squat performance (R2 = 0.388, p < 0.04). Around one third of strength performance is predicted by somatotype-assessed physique in physically active males. This could have important implications for the identification of those predisposed to perform well in sports containing strength-based movements and prescription of training programmes. PMID:29787610
The influence of somatotype on anaerobic performance.
Ryan-Stewart, Helen; Faulkner, James; Jobson, Simon
2018-01-01
The link between athlete physique and performance in sports is well established. However, a direct link between somatotype three-numeral rating and anaerobic performance has not yet been reported. The purpose of this study was to assess the relations between somatotype and anaerobic performance using both singular and multivariate analyses. Thirty-six physically active males (mean ± standard deviation age 26.0 ± 9.8 years; body mass 79.5 ± 12.9 kg; height 1.82 ± 0.07 m) were somatotype-rated using the Heath-Carter method. Subjects were assessed for 3 repetition maximum (3 RM) bench press and back squat, and completed a 30-second maximal sprint cycle test. Positive correlations were observed between mesomorphy and 3 RM bench press (r = 0.560, p < 0.001), mesomorphy and 3 RM back squat (r = 0.550, p = 0.001) and between mesomorphy and minimum power output (r = 0.357, p = 0.033). Negative correlations were observed between ectomorphy and 3 RM bench press (r = -0.381, p = 0.022), and ectomorphy and 3 RM back squat (r = -0.336, p = 0.045). Individual regression analysis indicated that mesomorphy was the best predictor of 3 RM bench press performance, with 31.4% of variance in 3 RM bench press performance accounted for by the mesomorphy rating (p < 0.001). A combination of mesomorphy and ectomorphy best predicted 3 RM back squat performance (R2 = 0.388, p < 0.04). Around one third of strength performance is predicted by somatotype-assessed physique in physically active males. This could have important implications for the identification of those predisposed to perform well in sports containing strength-based movements and prescription of training programmes.
Adams, Jenny; Schmid, Jack; Parker, Robert D; Coast, J Richard; Cheng, Dunlei; Killian, Aaron D; McCray, Stephanie; Strauss, Danielle; McLeroy Dejong, Sandra; Berbarie, Rafic
2014-03-15
Sternal precautions are intended to prevent complications after median sternotomy, but little data exist to support the consensus recommendations. To better characterize the forces on the sternum that can occur during everyday events, we conducted a prospective nonrandomized study of 41 healthy volunteers that evaluated the force exerted during bench press resistance exercise and while sneezing. A balloon-tipped esophageal catheter, inserted through the subject's nose and advanced into the thoracic cavity, was used to measure the intrathoracic pressure differential during the study activities. After the 1 repetition maximum (1-RM) was assessed, the subject performed the bench press at the following intensities, first with controlled breathing and then with the Valsalva maneuver: 40% of 1-RM (low), 70% of 1-RM (moderate), and 1-RM (high). Next, various nasal irritants were used to induce a sneeze. The forces on the sternum were calculated according to a cylindrical model, and a 2-tailed paired t test was used to compare the mean force exerted during a sneeze with the mean force exerted during each of the 6 bench press exercises. No statistically significant difference was found between the mean force from a sneeze (41.0 kg) and the mean total force exerted during moderate-intensity bench press exercise with breathing (41.4 kg). In conclusion, current guidelines and recommendations limit patient activity after a median sternotomy. Because these patients can repeatedly withstand a sneeze, our study indicates that they can withstand the forces from more strenuous activities than are currently allowed. Copyright © 2014 Elsevier Inc. All rights reserved.
The influence of isometric preload on power expressed during bench press in strength-trained men.
Bartolomei, Sandro; Fukuda, David H; Hoffman, Jay R; Stout, Jeffrey R; Merni, Franco
2017-03-01
The purpose of this study was to compare the power expressed during the bench press exercise in resistance-trained men following different pre-activation conditions. Twenty-two trained men (age 24.1 ± 1.7 years, height 178.6 ± 6.1 cm, body mass 81.1 ± 10.6 kg) completed a maximal effort bench press (1-RM) test (100.0 kg ± 8.1 kg). In a subsequent assessment, each participant performed concentric bench press movements with loads of 20%, 30%, 40% and 50% of their 1-RM preceded by either a concentric contraction (CC), a low isometric preload (LIP; 70% 1-RM) or a high isometric preload (HIP; 100% 1-RM) conditions. All movements were performed in a Smith machine with a settable quick-release device. Participants performed all three conditions in randomized fashion. Results indicated that power outputs during the bench press exercise following HIP were significantly (p < 0.05) greater than CC at 20% 1-RM (+9%), 30% 1-RM (+16%) and 40% 1-RM (+14%), and LIP at 20% 1-RM (+4%), 30% 1-RM (+20%) and 40% 1-RM (+15%). No differences were found between conditions at 50% 1-RM. Area under the force-power curve with HIP was greater (p < 0.05) than with CC and LIP. In conclusion, results of this study indicate that the use of a HIP (100% 1-RM) in trained participants results in significantly greater power output during the concentric phase of a multi-joint exercise when compared to standard concentric movement.
Damayanti, A; Ujang, Z; Salim, M R
2011-03-01
The main objective of this work was to determine the effectiveness of various biofouling reducers (BFRs) to operational condition in hybrid membrane bioreactor (MBR) of palm oil mill effluent (POME). A series of tests involving three bench scale (100 L) hybrid MBR were operated at sludge retention times (SRTs) of 30 days with biofouling reducer (BFR). Three different biofouling reducers (BFRs) were powdered actived carbon (PAC), zeolite (Ze), and Moringa oleifera (Mo) with doses of 4, 8 and 12 g L(-1) respectively were used. Short-term filtration trials and critical flux tests were conducted. Results showed that, all BFRs successfully removed soluble microbial products (SMP), for PAC, Ze, and Mo at 58%, 42%, and 48%, respectively. At their optimum dosages, PAC provided above 70% reductions and 85% in fouling rates during the short-term filtration and critical flux tests. Copyright © 2010 Elsevier Ltd. All rights reserved.
A Thin Film Multifunction Sensor for Harsh Environments
NASA Technical Reports Server (NTRS)
Wrbanek, John D.; Fralick, Gustave C.; Martin, Lisa C.; Blaha, Charles A.
2001-01-01
The status of work at NASA Glenn Research Center to develop a minimally intrusive integrated sensor to provide realtime measurement of strain, heat flux and flow in high temperature environments is presented in this paper. The sensor can be beneficial as a single package to characterize multiple stress and strain modes simultaneously on materials and components during engine development and validation. A major technical challenge is to take existing individual gauge designs and modify them into one integrated thin film sensor. Ultimately, the goal is to develop the ability to deposit the sensors directly onto internal engine parts or on a small thin substrate that can be attached to engine components. Several prototype sensors constructed of platinum, platinum-rhodium alloy, and alumina on constant-strain alumina beams have been built and bench-tested. The technical challenges of the design. construction, and testing are discussed. Data from the preliminary testing of the sensor array is presented. The future direction for the sensor development is discussed as well.
The design of a breadboard cryogenic optical delay line for DARWIN
NASA Astrophysics Data System (ADS)
van den Dool, Teun; Kamphues, Fred; Fouss, B.; Henrioulle, K.; Kooijman, P. P.; Visser, Martijn; Velsink, G.; Fleury, K.
2004-09-01
TNO TPD, in cooperation with Micromega-Dynamics, SRON, Dutch Space and CSL, has designed a compact breadboard cryogenic delay line for use in future space interferometry missions. The work is performed under ESA contract in preparation for the DARWIN mission. The breadboard (BB) delay line is representative of a future flight mechanism, with all materials and processes used being flight representative. The delay line has a single stage voice coil actuator for Optical Path Difference (OPD) control, driving a two-mirror cat"s eye. Magnetic bearings provide frictionless and wear free operation with zero-hysteresis. Overall power consumption is below the ESA specification of 2.5 W. The power dissipated on the optical bench at 40 K is considerably less than the maximum allowable 25 mW. The BB delay line will be built in the second half of 2004. The manufacturing and assembly phase is followed by a comprehensive test program, including functional testing at 40 K in 2005. The tests will be carried out by Alcatel Space and SAGEIS-CSO.
GeoCARB design maturity and geostationary heritage
NASA Astrophysics Data System (ADS)
Sawyer, Kevin; Clark, Charles; Katz, Noah; Kumar, Jack; Nast, Ted; Palmer, Alice
2013-09-01
Our companion paper `Progress in development of Tropospheric Infrared Mapping Spectrometers (TIMS): geostationary greenhouse gas (GHG) application' describes geoCARB performance and science. Here we describe a geoCARB instrument design study leading to near PDR maturity. It is based on heritage geostationary (AIA and HMI on SDO, SBIRS GEO-1 and upcoming GLM on GOES-R as examples) and other (IRIS and NIRcam) flight instrumentation. Heritage work includes experience and well developed specifications for near a-thermal carbon fiber honeycomb composite optical benches and optical element mounting design forms that utilize a "family" of mounts for nearly any type of optical element. The geoCARB approach utilizes composite optical benches and bipod flexures to kinematically mount optics. Tooling for alignment and staking of all elements is integral to the design and is "removed before flight" for mass minimization. GeoCARB requires a cryogenic region for focal planes and spectrometers but front end optics and main structure are designed to run much warmer. A star tracker is used for geoCARB posteriori geolocation including pseudo-diurnal thermal distortion characterization. It is kinematically mounted by low conductance thermal isolators directly on to the low expansion high stiffness composite bench that defines the master optical surfaces including the scanning mirrors. The thermal load from the camera heads is routed away from the bench heat pipes. Use of kinematic mounting is advantageous for low thermal conduction designs. Honeycomb composites enable the design's low thermal mechanical distortions.
First Impressions of a Scintrex CG-6 Portable Gravimeter in an Extensive Field Campaign
NASA Astrophysics Data System (ADS)
van Westrum, D.; Kanney, J.
2017-12-01
First Impressions of a Scintrex CG-6 Portable Gravimeter in an Extensive Field Campaign AGU Fall Meeting 2017 Derek van Westrum and Jeff Kanney NOAA's National Geodetic Survey conducted its third and final Geoid Slope Validation Survey (GSVS) this past summer in the rugged mountains of southern Colorado. In addition to leveling, long period GPS, and defelction of vertical observations, absolute gravity and vertical gravity gradients were measured at 235 bench marks (approximately 1.5 km spacing) along US-160 between Durango and Walsenburg, Colorado. In previous surveys (Texas-2011 and Iowa-2014), an A10 absolute gravimeter was used to measure graivty at approximately 10-15% of the bench marks. The remaining marks were determined by using LaCoste & Romberg relative gravimeters. The same relative instruments were also used to measure two-tier (linear) vertical gravity gradients at the A10 sites. In the current work - becuase of the rapidly changing terrain in the Rocky Mountains - it was decided to employ the A10 at all 235 bench marks, and acquire three-tier (quadratic) gradients at every bench mark using the new Scintrex CG-6 Autograv relative gravimeter. Using these results, we will provide a real worldsummary of the CG-6's behavior by examining noise levels, repeatability, and acquisition rates. In addition, the coincident A10 absolute data set allows us to evaluate the CG-6's accuracy, and allows us to simulate and discuss various relative gravity survey designs.
Experimental Realization of a Quantum Support Vector Machine
NASA Astrophysics Data System (ADS)
Li, Zhaokai; Liu, Xiaomei; Xu, Nanyang; Du, Jiangfeng
2015-04-01
The fundamental principle of artificial intelligence is the ability of machines to learn from previous experience and do future work accordingly. In the age of big data, classical learning machines often require huge computational resources in many practical cases. Quantum machine learning algorithms, on the other hand, could be exponentially faster than their classical counterparts by utilizing quantum parallelism. Here, we demonstrate a quantum machine learning algorithm to implement handwriting recognition on a four-qubit NMR test bench. The quantum machine learns standard character fonts and then recognizes handwritten characters from a set with two candidates. Because of the wide spread importance of artificial intelligence and its tremendous consumption of computational resources, quantum speedup would be extremely attractive against the challenges of big data.
Czugala, Monika; Gorkin, Robert; Phelan, Thomas; Gaughran, Jennifer; Curto, Vincenzo Fabio; Ducrée, Jens; Diamond, Dermot; Benito-Lopez, Fernando
2012-12-07
This work describes the first use of a wireless paired emitter detector diode device (PEDD) as an optical sensor for water quality monitoring in a lab-on-a-disc device. The microfluidic platform, based on an ionogel sensing area combined with a low-cost optical sensor, is applied for quantitative pH and qualitative turbidity monitoring of water samples at point-of-need. The autonomous capabilities of the PEDD system, combined with the portability and wireless communication of the full device, provide the flexibility needed for on-site water testing. Water samples from local fresh and brackish sources were successfully analysed using the device, showing very good correlation with standard bench-top systems.
NASA Astrophysics Data System (ADS)
Ciani, Giacomo; Chilton, Andrew; Olatunde, Taiwo; Apple, Stephen; Conklin, John W.; Mueller, Guido
2015-08-01
A LISA-like gravitational wave observatory is the choice candidate for ESA's L3 large mission scheduled to launch in 2034. The LISA Test Package (LTP) mission will launch later this year and test many critical technologies needed for such an observatory, among which are picometer interferometry in space and UV charge management of the Test Mass (TM). The design of these subsystems has been frozen many years ago during the final formulation of the LTP mission; since then, the LISA mission concept has evolved and new technologies have become available, making it possible to re-think the way these subsystem are implemented. With the final formulation of the L3 mission still years in the future and the LTP results expected in about one year, now is an ideal time look for areas of possible improvement and explore alternative implementations that can enhance performance, reduce costs or mitigate risks.Recently developed UV LED are lighter, cheaper and more powerful than traditional mercury lamps; in addition, their fast response time can be used to implement AC discharge techniques that can save even more space and power, and provide a more precise control of the charge.The most recent iteration of the mission baseline design allows for eliminating some of the optical components initially deemed essential; paired with the use of polarization multiplexing, this permits a redesign of the optical bench that simplifies the layout and enables a modular approach to machining and assembly, thus reducing the risks and costs associated with the current monolithic design without compromising the picometer stability of the optical path.Leveraging on extensive previous experience with LISA interferometry and the availability of a torsion pendulum-based LISA test-bed, the University of Florida LISA group is working at developing, demonstrating and optimizing both these technologies. I will describe the most recent advancements and results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isakson, K.; Vessell, A.L.
1994-07-01
Fermilab is presently phasing out all solvents containing Freon-113 (CFC-113) as part of the continuing Waste Minimization Program. These solvents are used primarily in cleaning the flux off of electronic circuit boards after soldering, specifically in bench type work. Title VI of the Clean Air Act mandates a production phase-out for ozone depleting substances, like CFC-113, by the year 2000. Our study addresses this issue by evaluating and choosing alternative non-CFC solvents to replace the CFC-1 13 solvents at Fermilab. Several potential non-CFC cleaning solvents were tested. The evaluation took place in three parts: controlled experimental evaluation, chemical composition evaluation,more » and employee performed evaluation. First, we performed a controlled nine-step procedure with the potential solvents where each was evaluated in categories such as cleaning effectiveness, odor, residue, type of output and drying time. Next, we listed the chemical composition of each solvent. We noted which solvents contained hydrochlorofluorocarbons because they are targeted for phase-out in the future and will be recognized as interim solutions only. Finally, after preliminary testing, five solvents were chosen as the best options. These solvents were sent to be tested by Fermilab employees who use such materials. Their opinions are valuable not only because they are knowledgeable in this field, but also because they will be using the solvents chosen to replace the CFC-113 solvents. The results favored two ``best alternatives``: Safezone Solvent Flux Remover by Miller-Stephenson and E-Series CFC Free Flux-Off 2000 by Chemtech. Another possible solution also pursued is the no-clean solder option. In our study, we were not able to thoroughly investigate the many types of no-clean solders because of time and financial constraints. The testing that was done, however, showed that no-clean solder was a viable alternative in many cases.« less
Development of a solar charged laboratory bench power supply
NASA Astrophysics Data System (ADS)
Ayara, W. A.; Omotosho, T. V.; Usikalu, M. R.; Singh, M. S. J.; Suparta, W.
2017-05-01
This product is an improvement on available DC laboratory bench power supply. It is capable of delivering low voltage Alternating Current (AC) and Direct Current (DC) to carry out basic laboratory experiment for both secondary schools and also at higher education institutions. The power supply is capable of delivering fixed DC voltages of 5V, 9V, 12V, variable voltage of between 1.25-30V and a 12V AC voltage. Also Incorporated is a USB port that allows for charging cell phones and other mobile devices, and a dedicated 12V DC output to power 5-7 Watt LED bulb to provide illumination in the laboratory for the instructor who may need to work at night in the absence of utility power.
Influence of Dissipative Particle Dynamics parameters and wall models on planar micro-channel flows
NASA Astrophysics Data System (ADS)
Wang, Yuyi; She, Jiangwei; Zhou, Zhe-Wei; microflow Group Team
2017-11-01
Dissipative Particle Dynamics (DPD) is a very effective approach in simulating mesoscale hydrodynamics. The influence of solid boundaries and DPD parameters are typically very strong in DPD simulations. The present work studies a micro-channel Poisseuille flow. Taking the neutron scattering experiment and molecular dynamics simulation result as bench mark, the DPD results of density distribution and velocity profile are systematically studied. The influence of different levels of coarse-graining, the number densities of wall and fluid, conservative force coefficients, random and dissipative force coefficients, different wall model and reflective boundary conditions are discussed. Some mechanisms behind such influences are discussed and the artifacts in the simulation are identified with the bench mark. Chinese natural science foundation (A020405).
30 CFR 57.22604 - Blasting from the surface (II-B mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
... MINES Safety Standards for Methane in Metal and Nonmetal Mines Explosives § 57.22604 Blasting from the surface (II-B mines). All development, production, and bench rounds shall be initiated from the surface... methane tests shall not enter the mine until all blast areas have been tested for methane. ...
30 CFR 57.22604 - Blasting from the surface (II-B mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
... MINES Safety Standards for Methane in Metal and Nonmetal Mines Explosives § 57.22604 Blasting from the surface (II-B mines). All development, production, and bench rounds shall be initiated from the surface... methane tests shall not enter the mine until all blast areas have been tested for methane. ...
30 CFR 57.22604 - Blasting from the surface (II-B mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
... MINES Safety Standards for Methane in Metal and Nonmetal Mines Explosives § 57.22604 Blasting from the surface (II-B mines). All development, production, and bench rounds shall be initiated from the surface... methane tests shall not enter the mine until all blast areas have been tested for methane. ...
30 CFR 57.22604 - Blasting from the surface (II-B mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
... MINES Safety Standards for Methane in Metal and Nonmetal Mines Explosives § 57.22604 Blasting from the surface (II-B mines). All development, production, and bench rounds shall be initiated from the surface... methane tests shall not enter the mine until all blast areas have been tested for methane. ...
30 CFR 57.22604 - Blasting from the surface (II-B mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
... MINES Safety Standards for Methane in Metal and Nonmetal Mines Explosives § 57.22604 Blasting from the surface (II-B mines). All development, production, and bench rounds shall be initiated from the surface... methane tests shall not enter the mine until all blast areas have been tested for methane. ...
NASA Technical Reports Server (NTRS)
Tolmei, V. R.
1982-01-01
Proposed circuit would monitor vibration spectrum of engines under test or in service. It could detect subtle out-of-specification conditions and could be programed to shut down engine if an out-of-limits condition develops. Possible uses of monitor are in bench testing automobiles and outboard motors and as a safety device in very critical engine applications.
In a recently completed test program, bench-scale laboratory studies at Arizona State University (ASU) in Tempe, AZ, and pilot-scale studies in a simulated field test situation at Zentox Corp in Ocala, FL, were performed to evaluate the integration of gas-solid ultraviolet (UV) p...
OPERATIONS AND RESEARCH AT THE U.S. EPA INCINERATION RESEARCH FACILITY: ANNUAL REPORT FOR FY94
Fiscal year 1994 (FY94, October 1, 1993 through September 30,1994) saw the continuation of incineration research testing efforts at the IRF. uring the year, two major pilot-scale programs were completed and a third carried to near-completion, and two bench-scale test programs of ...
42 CFR Appendix - Tables to Subpart L of Part 84
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Tables to Subpart L of Part 84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Chemical Cartridge Respirators Bench tests; gas and vapor tests; minimum requirements;...
Integrated Thermal Modules for Cooling Silicon and Silicon Carbide Power Modules
2007-06-11
analyses, bench tests, and motor tests comprise the program. The ITMs, in place of standard heatsinks, use a highly conductive pyrolytic graphite to...passively cool power modules. Initial results show that even simple ITMs can lower chip temperatures by 20 deg. C and 10 deg. C with engine oil and
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
Velocity- and power-load relationships of the bench pull vs. bench press exercises.
Sánchez-Medina, L; González-Badillo, J J; Pérez, C E; Pallarés, J G
2014-03-01
This study compared the velocity- and power-load relationships of the antagonistic upper-body exercises of prone bench pull (PBP) and bench press (BP). 75 resistance-trained athletes performed a progressive loading test in each exercise up to the one-repetition maximum (1RM) in random order. Velocity and power output across the 30-100% 1RM were significantly higher for PBP, whereas 1RM strength was greater for BP. A very close relationship was observed between relative load and mean propulsive velocity for both BP (R2=0.97) and PBP (R2=0.94) which enables us to estimate %1RM from velocity using the obtained prediction equations. Important differences in the load that maximizes power output (Pmax) and the power profiles of both exercises were found according to the outcome variable used: mean (MP), peak (PP) or mean propulsive power (MPP). When MP was considered, the Pmax load was higher (56% BP, 70% PBP) than when PP (37% BP, 41% PBP) or MPP (37% BP, 46% PBP) were used. For each variable there was a broad range of loads at which power output was not significantly different. The differing velocity- and power-load relationships between PBP and BP seem attributable to the distinct muscle architecture and moment arm levers involved in these exercises. © Georg Thieme Verlag KG Stuttgart · New York.
Reis, Leonardo F.; Minervino, Antonio H. H.; Araújo, Carolina A. S. C.; Sousa, Rejane S.; Oliveira, Francisco L. C.; Rodrigues, Frederico A. M. L.; Meira-Júnior, Enoch B. S.; Barrêto-Júnior, Raimundo A.; Mori, Clara S.; Ortolani, Enrico L.
2014-01-01
We aimed to compare the measurements of sheep ruminal pH using a continuous telemetry system or a bench pH meter using sheep with different degrees of ruminal pH. Ruminal lactic acidosis was induced in nine adult crossbred Santa Ines sheep by the administration of 15 g of sucrose per kg/BW. Samples of rumen fluid were collected at the baseline, before the induction of acidosis (T 0) and at six, 12, 18, 24, 48, and 72 hours after the induction for pH measurement using a bench pH meter. During this 72-hour period, all animals had electrodes for the continuous measurement of pH. The results were compared using the Bland-Altman analysis of agreement, Pearson coefficients of correlation and determination, and paired analysis of variance with Student's t-test. The measurement methods presented a strong correlation (r = 0.94, P < 0.05) but the rumen pH that was measured continuously using a telemetry system resulted in lower values than the bench pH meter (overall mean of 5.38 and 5.48, resp., P = 0.0001). The telemetry system was able to detect smaller changes in rumen fluid pH and was more accurate in diagnosing both subacute ruminal lactic acidosis and acute ruminal lactic acidosis in sheep. PMID:24967422
Khater, Nazih; Shen, Jim; Arenas, Javier; Keheila, Mohamed; Alsyouf, Muhannad; Martin, Jacob A; Lightfoot, Michelle A; Li, Roger; Olgin, Gaudencio; Smith, Jason C; Baldwin, D Duane
2016-11-01
Traditional techniques for obtaining percutaneous renal access utilize continuous fluoroscopy. In an attempt to minimize radiation exposure, we describe a novel laser direct alignment radiation reduction technique (DARRT) for percutaneous access and test it in a bench-top model. In this randomized-controlled bench-top study, 20 medical personnel obtained renal accesses using both the conventional bullseye technique and the laser DARRT. The primary endpoint was total fluoroscopy time. Secondary endpoints included insertion time, puncture attempts, course corrections, and subjective procedural difficulty. In the laser DARRT, fluoroscopy was used with the C-arm positioned with the laser beam at a 30° angle. The access needle and hub were aligned with the laser beam. Effective caliceal puncture was confirmed with fluoroscopy and direct vision. The Paired samples Wilcoxon signed rank test was used for statistical analysis with significance at p < 0.05. A total of 120 needle placements were recorded. Fluoroscopy time for needle access using the laser DARRT was significantly lower than the bullseye technique in all groups as follows: attendings (7.09 vs 18.51 seconds; p < 0.001), residents (6.55 vs 13.93 seconds; p = 0.001), and medical students (6.69 vs 20.22 seconds; p < 0.001). Students rated the laser DARRT easier to use (2.56 vs 4.89; p < 0.001). No difference was seen in total access time, puncture attempts, or course corrections between techniques. The laser DARRT reduced fluoroscopy time by 63%, compared with the conventional bullseye technique. The least experienced users found the laser DARRT significantly easier to learn. This novel technique is promising and merits additional testing in animal and human models.