Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee
2015-07-01
To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.
Treating contaminated organics using the DETOX process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elsberry, K.D.; Dhooge, P.M.
1993-05-01
Waste matrices containing organics, radionuclides, and metals pose difficult problems in waste treatment and disposal when the organic compounds and/or metals are considered to be hazardous. This paper describes the results of bench-scale studies of DETOX applied to the components of liquid mixed wastes, with the goal of establishing parameters for designing a prototype waste treatment unit. Apparent organic reaction rate orders and the dependence of apparent reaction rate on solution composition and the contact area were measured for vacuum pump oil scintillation fluids, and trichloroethylene. Reaction rate was superior in chloride-based solutions and was proportional to the contact areamore » above about 2% w/w loading of organic. Oxidations in a 4-liter volume, mixed bench-top reactor have given destruction efficiencies of 99.9999 + % for common organics. Reaction rates achieved in the mixed bench-top reactor were one to two orders of magnitude greater than had been achieved in unmixed reactions; a thoroughly mixed reactor should be capable of oxidizing 10 to 100 + grams of organic per liter-hour. Results are also presented on the solvation efficiency of DETOX for mercury, cerium, and neodymium, and for removal/destruction of organics sorbed on vermiculite. The next stage of development will be converting the bench-top unit to continuous processing.« less
EUS Needle Identification Comparison and Evaluation study (with videos).
Tang, Shou-Jiang; Vilmann, Andreas S; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin Teodor; Fink, Peter P; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T; van der Heijden, Erik H F M; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R; Lee, Linda S; Aslanian, Harry R; Wang, Andrew Y; Shami, Vanessa M; Markowitz, Arnold; Siddiqui, Ali A; Mishra, Girish; Scheiman, James M; Isenberg, Gerard; Siddiqui, Uzma D; Shah, Raj J; Buxbaum, James; Watson, Rabindra R; Willingham, Field F; Bhutani, Manoop S; Levy, Michael J; Harris, Cynthia; Wallace, Michael B; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D'Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S; Freeman, Simon; McCowan, Timothy C; de Araujo, Cyrillo Rodrigues; Patel, Akash; Ali, Mohammad Adel; Campbell, Garth; Chen, Edward; Vilmann, Peter
2016-09-01
EUS-guided FNA or biopsy sampling is widely practiced. Optimal sonographic visualization of the needle is critical for image-guided interventions. Of the several commercially available needles, bench-top testing and direct comparison of these needles have not been done to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Descriptive bench-top testing and comparison of 8 commonly used EUS-FNA needles (all size 22 gauge): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in GI US examination who were unfamiliar with EUS needle devices. There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, 1 prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (P < .01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%-75% worse, P < .001). All FNA needles have their inherent and different echogenicities, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. Copyright © 2016 American Society for Gastrointestinal Endoscopy. All rights reserved.
Endomicroscopy imaging of epithelial structures using tissue autofluorescence
NASA Astrophysics Data System (ADS)
Lin, Bevin; Urayama, Shiro; Saroufeem, Ramez M. G.; Matthews, Dennis L.; Demos, Stavros G.
2011-04-01
We explore autofluorescence endomicroscopy as a potential tool for real-time visualization of epithelial tissue microstructure and organization in a clinical setting. The design parameters are explored using two experimental systems--an Olympus Medical Systems Corp. stand-alone clinical prototype probe, and a custom built bench-top rigid fiber conduit prototype. Both systems entail ultraviolet excitation at 266 nm and/or 325 nm using compact laser sources. Preliminary results using ex vivo animal and human tissue specimens suggest that this technology can be translated toward in vivo application to address the need for real-time histology.
Handheld magnetic sensor for measurement of tension
NASA Astrophysics Data System (ADS)
Singal, K.; Rajamani, R.
2012-04-01
This letter develops an analytical formulation for measurement of tension in a string using a handheld sensor. By gently pushing the sensor against the string, the tension in the string can be obtained. An experimental sensor prototype is constructed to verify the analytical formulation. The centimeter-sized prototype utilizes three moving pistons and magnetic field based measurements of their positions. Experimental data show that the sensor can accurately measure tension on a bench top rig. The developed sensor could be useful in a variety of orthopedic surgical procedures, including knee replacement, hip replacement, ligament repair, shoulder stabilization, and tendon repair.
Bench-scale operation of the DETOX wet oxidation process for mixed waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhooge, P.M.
1993-01-01
Waste matrices containing organics, radionuclides, and metals pose difficult problems in waste treatment and disposal when the organic compounds and/or metals are considered to be hazardous. A means of destroying hazardous organic components while safely containing and concentrating metals would be extremely useful in mixed waste volume reduction or conversion to a radioactive-only form. Previous studies have found the DETOX, a patented process utilizing a novel catalytic wet oxidation by iron(III) oxidant, cold have successful application to mixed wastes, and to many other waste types. This paper describes the results of bench scale studies of DETOX applied to the componentsmore » of liquid mixed wastes, with the goal of establishing parameters for the design of a prototype waste treatment unit. Apparent organic reaction rate orders, and the dependence of apparent reaction rate on the contact area, were measured for vacuum pump oil, scintillation fluids, and trichloroethylene. It was found that reaction rate was proportional to contact area above about 2.% w/w loading of organic. Oxidations in a 4 liter. volume, mixed bench top reactor have given destruction efficiencies of 99.9999+% for common organics. Reaction rates achieved in the mixedbench top reactor were one to two orders of magnitude greater than had been achieved in unmixed reactions; a thoroughly mixed reactor should be capable of oxidizing 10. to 100.+ grams of organic per liter-hour,depending on the nature and concentration of the organic.« less
Bench-scale operation of the DETOX wet oxidation process for mixed waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhooge, P.M.
1993-03-01
Waste matrices containing organics, radionuclides, and metals pose difficult problems in waste treatment and disposal when the organic compounds and/or metals are considered to be hazardous. A means of destroying hazardous organic components while safely containing and concentrating metals would be extremely useful in mixed waste volume reduction or conversion to a radioactive-only form. Previous studies have found the DETOX, a patented process utilizing a novel catalytic wet oxidation by iron(III) oxidant, cold have successful application to mixed wastes, and to many other waste types. This paper describes the results of bench scale studies of DETOX applied to the componentsmore » of liquid mixed wastes, with the goal of establishing parameters for the design of a prototype waste treatment unit. Apparent organic reaction rate orders, and the dependence of apparent reaction rate on the contact area, were measured for vacuum pump oil, scintillation fluids, and trichloroethylene. It was found that reaction rate was proportional to contact area above about 2.% w/w loading of organic. Oxidations in a 4 liter. volume, mixed bench top reactor have given destruction efficiencies of 99.9999+% for common organics. Reaction rates achieved in the mixedbench top reactor were one to two orders of magnitude greater than had been achieved in unmixed reactions; a thoroughly mixed reactor should be capable of oxidizing 10. to 100.+ grams of organic per liter-hour,depending on the nature and concentration of the organic.« less
NASA Astrophysics Data System (ADS)
Ouyang, Bing; Hou, Weilin; Gong, Cuiling; Caimi, Frank M.; Dalgleish, Fraser R.; Vuorenkoski, Anni K.
2016-05-01
The Compressive Line Sensing (CLS) active imaging system has been demonstrated to be effective in scattering mediums, such as turbid coastal water through simulations and test tank experiments. Since turbulence is encountered in many atmospheric and underwater surveillance applications, a new CLS imaging prototype was developed to investigate the effectiveness of the CLS concept in a turbulence environment. Compared with earlier optical bench top prototype, the new system is significantly more robust and compact. A series of experiments were conducted at the Naval Research Lab's optical turbulence test facility with the imaging path subjected to various turbulence intensities. In addition to validating the system design, we obtained some unexpected exciting results - in the strong turbulence environment, the time-averaged measurements using the new CLS imaging prototype improved both SNR and resolution of the reconstructed images. We will discuss the implications of the new findings, the challenges of acquiring data through strong turbulence environment, and future enhancements.
Strain actuated aeroelastic control
NASA Technical Reports Server (NTRS)
Lazarus, Kenneth B.
1992-01-01
Viewgraphs on strain actuated aeroelastic control are presented. Topics covered include: structural and aerodynamic modeling; control law design methodology; system block diagram; adaptive wing test article; bench-top experiments; bench-top disturbance rejection: open and closed loop response; bench-top disturbance rejection: state cost versus control cost; wind tunnel experiments; wind tunnel gust alleviation: open and closed loop response at 60 mph; wind tunnel gust alleviation: state cost versus control cost at 60 mph; wind tunnel command following: open and closed loop error at 60 mph; wind tunnel flutter suppression: open loop flutter speed; and wind tunnel flutter suppression: closed loop state cost curves.
Evaluation of a Bench Top Mechanical Delinter
USDA-ARS?s Scientific Manuscript database
This presentation will report on current research associated with a new mechancial delinter being developed at the Cotton Production and Processing Research Unit in conjunction with Cotton Inc. A bench-top version of the new mechanical delinter was built and evaluated to determine operational speeds...
USDA-ARS?s Scientific Manuscript database
Juice production is a multibillion dollar industry and an economical way to use fruit past seasonal harvests. To evaluate how production steps influence not-from-concentrate (NFC) blueberry (Vaccinium sp.) juice recovery, bench top and pilot scale experiments were performed. In bench-top, southern h...
Optimising Microbial Growth with a Bench-Top Bioreactor
ERIC Educational Resources Information Center
Baker, A. M. R.; Borin, S. L.; Chooi, K. P.; Huang, S. S.; Newgas, A. J. S.; Sodagar, D.; Ziegler, C. A.; Chan, G. H. T.; Walsh, K. A. P.
2006-01-01
The effects of impeller size, agitation and aeration on the rate of yeast growth were investigated using bench-top bioreactors. This exercise, carried out over a six-month period, served as an effective demonstration of the importance of different operating parameters on cell growth and provided a means of determining the optimisation conditions…
NASA Technical Reports Server (NTRS)
Quinn, Gregory J.; Strange, Jeremy; Jennings, Mallory
2013-01-01
NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system s liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems (UTAS), but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.57 lb. Performance of the heat exchanger met the requirements and the model predictions. The water side and gas side pressure drops were less 0.8 psid and 0.5 inches of water, respectively, and an effectiveness of 94% was measured at the nominal air side pressure of 4.1 psia.
Novo, P; Chu, V; Conde, J P
2014-07-15
The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.
Hack, B J; Ramon, S G; Hagen, Z A; Theran, M E; Burkhardt, J D; Gillies, G T
2015-01-01
This study investigated the use of direct visualization to enhance minimally invasive epicardial procedures. A commercially available miniature camera was placed in a prototype subxiphoid introducer needle and bench top, in vitro and in vivo tests of system performance were made during simulated and actual attempts at pericardial access and cardio-endoscopy. This system had an unshielded field of view of 100° and a resolution of 220 × 224 pixels. When a sleeve used to maintain depth of field was slid past the distal tip of the camera probe, the field of view would decrease by ≈15° per millimetre of sleeve extension, but without loss of image quality. While tests during in vivo subxiphoid access in a porcine model revealed that the pericardial membrane was difficult to localize, the results also showed excellent resolution of the coronary arteries on the epicardial surface. These findings and potential improvements are discussed in detail.
Saem, Sokunthearath; Zhu, Yujie; Luu, Helen; Moran-Mirabal, Jose
2017-03-31
In recent years, efforts in the development of lab-on-a-chip (LoC) devices for point-of-care (PoC) applications have increased to bring affordable, portable, and sensitive diagnostics to the patients' bedside. To reach this goal, research has shifted from using traditional microfabrication methods to more versatile, rapid, and low-cost options. This work focuses on the benchtop fabrication of a highly sensitive, fully transparent, and flexible poly (dimethylsiloxane) (PDMS) microfluidic (μF) electrochemical cell sensor. The μF device encapsulates 3D structured gold and platinum electrodes, fabricated using a shape-memory polymer shrinking method, which are used to set up an on-chip electrochemical cell. The PDMS to PDMS-structured electrode bonding protocol to fabricate the μF chip was optimized and found to have sufficient bond strength to withstand up to 100 mL/min flow rates. The sensing capabilities of the on-chip electrochemical cell were demonstrated by using cyclic voltammetry to monitor the adhesion of murine 3T3 fibroblasts in the presence of a redox reporter. The charge transfer across the working electrode was reduced upon cell adhesion, which was used as the detection mechanism, and allowed the detection of as few as 24 cells. The effective utilization of simple and low cost bench-top fabrication methods could accelerate the prototyping and development of LoC technologies and bring PoC diagnostics and personalized medicine to the patients' bedside.
Saem, Sokunthearath; Zhu, Yujie; Luu, Helen; Moran-Mirabal, Jose
2017-01-01
In recent years, efforts in the development of lab-on-a-chip (LoC) devices for point-of-care (PoC) applications have increased to bring affordable, portable, and sensitive diagnostics to the patients’ bedside. To reach this goal, research has shifted from using traditional microfabrication methods to more versatile, rapid, and low-cost options. This work focuses on the benchtop fabrication of a highly sensitive, fully transparent, and flexible poly (dimethylsiloxane) (PDMS) microfluidic (μF) electrochemical cell sensor. The μF device encapsulates 3D structured gold and platinum electrodes, fabricated using a shape-memory polymer shrinking method, which are used to set up an on-chip electrochemical cell. The PDMS to PDMS-structured electrode bonding protocol to fabricate the μF chip was optimized and found to have sufficient bond strength to withstand up to 100 mL/min flow rates. The sensing capabilities of the on-chip electrochemical cell were demonstrated by using cyclic voltammetry to monitor the adhesion of murine 3T3 fibroblasts in the presence of a redox reporter. The charge transfer across the working electrode was reduced upon cell adhesion, which was used as the detection mechanism, and allowed the detection of as few as 24 cells. The effective utilization of simple and low cost bench-top fabrication methods could accelerate the prototyping and development of LoC technologies and bring PoC diagnostics and personalized medicine to the patients’ bedside. PMID:28362329
The negative ion electrospray mass spectra of six bromo- and chloroacetic acids were measured using two different electrospray interfaces and single quadrupole and bench-top time-of-flight mass spectrometers. With each acid at 50 ug/mL in aqueous methanol at pH 10, the anions ob...
A Method to Estimate Fabric Particle Penetration Performance
2014-09-08
may be needed to improve the correlation between wind tunnel component sleeve tests and bench top swatch test. The ability to predict multi-layered...within the fabric/component gap may be needed to improve the correlation between wind tunnel component sleeve tests and bench top swatch test...impermeable garment . Heat stress becomes a major problem with this approach however, as normal physiological heat loss mechanisms (especially sweat
Development of Fuzzy Logic Controller for Quanser Bench-Top Helicopter
NASA Astrophysics Data System (ADS)
Jafri, M. H.; Mansor, H.; Gunawan, T. S.
2017-11-01
Bench-top helicopter is a laboratory scale helicopter that usually used as a testing bench of the real helicopter behavior. This helicopter is a 3 Degree of Freedom (DOF) helicopter which works by three different axes wshich are elevation, pitch and travel. Thus, fuzzy logic controller has been proposed to be implemented into Quanser bench-top helicopter because of its ability to work with non-linear system. The objective for this project is to design and apply fuzzy logic controller for Quanser bench-top helicopter. Other than that, fuzzy logic controller performance system has been simulated to analyze and verify its behavior over existing PID controller by using Matlab & Simulink software. In this research, fuzzy logic controller has been designed to control the elevation angle. After simulation has been performed, it can be seen that simulation result shows that fuzzy logic elevation control is working for 4°, 5° and 6°. These three angles produce zero steady state error and has a fast response. Other than that, performance comparisons have been performed between fuzzy logic controller and PID controller. Fuzzy logic elevation control has a better performance compared to PID controller where lower percentage overshoot and faster settling time have been achieved in 4°, 5° and 6° step response test. Both controller are have zero steady state error but fuzzy logic controller is managed to produce a better performance in term of settling time and percentage overshoot which make the proposed controller is reliable compared to the existing PID controller.
Malc, Ewa P.; Jayakody, Chatura N.; Tsuruta, James K.; Mieczkowski, Piotr A.; Janzen, William P.; Dayton, Paul A.
2015-01-01
A perfluorocarbon nanodroplet formulation is shown to be an effective cavitation enhancement agent, enabling rapid and consistent fragmentation of genomic DNA in a standard ultrasonic water bath. This nanodroplet-enhanced method produces genomic DNA libraries and next-generation sequencing results indistinguishable from DNA samples fragmented in dedicated commercial acoustic sonication equipment, and with higher throughput. This technique thus enables widespread access to fast bench-top genomic DNA fragmentation. PMID:26186461
INTERIOR VIEW, NORTH QUARRY, LOOKING WEST. IN THE FOREGROUND ON ...
INTERIOR VIEW, NORTH QUARRY, LOOKING WEST. IN THE FOREGROUND ON THE FIRST BENCH, POWDER HILLS ARE PRIMED FOR DOLOMITE EXTRACTION. ON THE SECOND BENCH, THE DRILL TEAM IS LAYING OUT THE NEXT SHOTS. ON THE TOP BENCH, A 245 CATERPILLAR LOADER FILLS A 55-TON CATERPILLAR ROCK TRUCK WITH EXTRACTED DOLOMITE FOR TRANSPORT TO THE DOLOMITE CRUSHING AND SCREENING PLANT. - Wade Sand & Gravel Company, North Quarry, State Highway 78, Thomas, Jefferson County, AL
NASA Technical Reports Server (NTRS)
Turner, Travis L.; Kidd, Reggie T.; Hartl, Darren J.; Scholten, William D.
2013-01-01
Airframe noise is a significant part of the overall noise produced by typical, transport-class aircraft during the approach and landing phases of flight. Leading-edge slat noise is a prominent source of airframe noise. The concept of a slat-cove filler was proposed in previous work as an effective means of mitigating slat noise. Bench-top models were deployed at 75% scale to study the feasibility of producing a functioning slat-cove filler. Initial results from several concepts led to a more-focused effort investigating a deformable structure based upon pseudoelastic SMA materials. The structure stows in the cavity between the slat and main wing during cruise and deploys simultaneously with the slat to guide the aerodynamic flow suitably for low noise. A qualitative parametric study of SMA-enabled, slat-cove filler designs was performed on the bench-top. Computational models were developed and analyses were performed to assess the displacement response under representative aerodynamic load. The bench-top and computational results provide significant insight into design trades and an optimal design.
A Reusable, Compliant, Small Volume Blood Reservoir for In Vitro Hemolysis Testing.
Olia, Salim E; Herbertson, Luke H; Malinauskas, Richard A; Kameneva, Marina V
2017-02-01
Bench-top in vitro hemolysis testing is a fundamental tool during the design and regulatory safety evaluation of blood-contacting medical devices. While multiple published experimental protocols exist, descriptions of the test loop reservoir remain ambiguous. A critical fixture within the circuit, there is no readily available blood reservoir that ensures thorough mixing and complete air evacuation: two major factors which can affect results. As part of the Food and Drug Administration (FDA) Critical Path Initiative, we developed a three-piece reservoir consisting of a 3D-printed base, a plastic clamp set, and a medical-grade blood bag. This simple, reusable, and cost-effective design was used successfully in the hemolysis assessment of FDA benchmark nozzles and prototype rotary blood pumps, and may be useful as an integral component to any in vitro blood circulation loop. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Control of helicopter rotorblade aerodynamics
NASA Technical Reports Server (NTRS)
Fabunmi, James A.
1991-01-01
The results of a feasibility study of a method for controlling the aerodynamics of helicopter rotorblades using stacks of piezoelectric ceramic plates are presented. A resonant mechanism is proposed for the amplification of the displacements produced by the stack. This motion is then converted into linear displacement for the actuation of the servoflap of the blades. A design which emulates the actuation of the servoflap on the Kaman SH-2F is used to demonstrate the fact that such a system can be designed to produce the necessary forces and velocities needed to control the aerodynamics of the rotorblades of such a helicopter. Estimates of the electrical power requirements are also presented. A Small Business Innovation Research (SBIR) Phase 2 Program is suggested, whereby a bench-top prototype of the device can be built and tested. A collaborative effort between AEDAR Corporation and Kaman Aerospace Corporation is anticipated for future effort on this project.
NASA Technical Reports Server (NTRS)
Jennings, Mallory; Quinn, Gregory; Strange, Jeremy
2012-01-01
NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system's liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems, but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.6 lb. The water side and gas side pressure drops were 0.8 psid and 0.5 inches of water, respectively. Performance of the heat exchanger at the nominal pressure of 4.1 psia was measured at 94%, while a gas inlet pressure of 25 psia resulted in an effectiveness of 84%. These results compared well with the model, which was scaled for the small size. Modeling of certain phenomena that affect performance, such as flow distribution in the headers was particularly difficult due to the small size of the heat exchanger. Data from the tests has confirmed the correction factors that were used in these parts of the model.
Huang, Yulu; Wang, Haipeng; Wang, Shaoheng; ...
2016-12-09
Quarter wavelength resonator (QWR) based deflecting cavities with the capability of supporting multiple odd-harmonic modes have been developed for an ultrafast periodic kicker system in the proposed Jefferson Lab Electron Ion Collider (JLEIC, formerly MEIC). Previous work on the kicking pulse synthesis and the transverse beam dynamics tracking simulations show that a flat-top kicking pulse can be generated with minimal emittance growth during injection and circulation of the cooling electron bunches. This flat-top kicking pulse can be obtained when a DC component and 10 harmonic modes with appropriate amplitude and phase are combined together. To support 10 such harmonic modes,more » four QWR cavities are used with 5, 3, 1, and 1 modes, respectively. In the multiple-mode cavities, several slightly tapered segments of the inner conductor are introduced to tune the higher order deflecting modes to be harmonic, and stub tuners are used to fine tune each frequency to compensate for potential errors. In this paper, we summarize the electromagnetic design of the five-mode cavity, including the geometry optimization to get high transverse shunt impedance, the frequency tuning and sensitivity analysis, and the single loop coupler design for coupling to all of the harmonic modes. In particular we report on the design and fabrication of a half-scale copper prototype of this proof-of-principle five-odd-mode cavity, as well as the rf bench measurements. Lastly, we demonstrate mode superposition in this cavity experimentally, which illustrates the kicking pulse generation concept.« less
Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali
2016-09-01
Scarce information exists about quality requirements and objective evaluation of performance of large veterinary bench top hematology analyzers. The study was aimed at comparing the observed total error (TEobs ) derived from meta-analysis of published method validation data to the total allowable error (TEa ) for veterinary hematology variables in small animals based on experts' opinions. Ideally, TEobs should be < TEa . An online survey was sent to veterinary experts in clinical pathology and small animal internal medicine for providing the maximal allowable deviation from a given result for each variable. Percent of TEa = (allowable median deviation/clinical threshold) * 100%. Second, TEobs for 3 laser-based bench top hematology analyzers (ADVIA 2120; Sysmex XT2000iV, and CellDyn 3500) was calculated based on method validation studies published between 2005 and 2013 (n = 4). The percent TEobs = 2 * CV (%) + bias (%). The CV was derived from published studies except for the ADVIA 2120 (internal data), and bias was estimated from the regression equation. A total of 41 veterinary experts (19 diplomates, 8 residents, 10 postgraduate students, 4 anonymous specialists) responded. The proposed range of TEa was wide, but generally ≤ 20%. The TEobs was < TEa for all variables and analyzers except for canine and feline HGB (high bias, low CV) and platelet counts (high bias, high CV). Overall, veterinary bench top analyzers fulfilled experts' requirements except for HGB due to method-related bias, and platelet counts due to known preanalytic/analytic issues. © 2016 American Society for Veterinary Clinical Pathology.
17. Interior view of courtroom looking towards judge's bench; showing ...
17. Interior view of courtroom looking towards judge's bench; showing built in linear seating on both ends of room, clerical desk and equipment, through wall air conditioning units, exterior windows and door; north end of west wing on top floor; view to northwest. - Ellsworth Air Force Base, Group Administration & Secure Storage Building, 2372 Westover Avenue, Blackhawk, Meade County, SD
Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Matsuda, Chu; Yamamoto, Hirofumi; Mizushima, Tsunekazu; Mori, Masaki; Doki, Yuichiro; Nakajima, Kiyokazu
2018-06-01
Modern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings. SBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries. In the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery. We successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.
NASA Astrophysics Data System (ADS)
Briguglio, R.; Xompero, M.; Riccardi, A.; Lisi, F.; Duò, F.; Vettore, C.; Gallieni, D.; Tintori, M.; Lazzarini, P.; Patauner, C.; Biasi, R.; D'Amato, F.; Pucci, M.; Pereira do Carmo, João.
2017-11-01
The concept of a low areal density primary mirror, actively controlled by actuators, has been investigated through a demonstration prototype. A spherical mirror (400 mm diameter, 2.7 Kg mass) has been manufactured and tested in laboratory and on the optical bench, to verify performance, controllability and optical quality. In the present paper we will describe the prototype and the test results.
NASA Astrophysics Data System (ADS)
Lee, Seung Yup; Na, Kyounghwan; Pakela, Julia M.; Scheiman, James M.; Yoon, Euisik; Mycek, Mary-Ann
2017-02-01
We present the design, development, and bench-top verification of an innovative compact clinical system including a miniaturized handheld optoelectronic sensor. The integrated sensor was microfabricated with die-level light-emitting diodes and photodiodes and fits into a 19G hollow needle (internal diameter: 0.75 mm) for optical sensing applications in solid tissues. Bench-top studies on tissue-simulating phantoms have verified system performance relative to a fiberoptic based tissue spectroscopy system. With dramatically reduced system size and cost, the technology affords spatially configurable designs for optoelectronic light sources and detectors, thereby enabling customized sensing configurations that would be impossible to achieve with needle-based fiber-optic probes.
Evaluation of a novel flexible snake robot for endoluminal surgery.
Patel, Nisha; Seneci, Carlo A; Shang, Jianzhong; Leibrandt, Konrad; Yang, Guang-Zhong; Darzi, Ara; Teare, Julian
2015-11-01
Endoluminal therapeutic procedures such as endoscopic submucosal dissection are increasingly attractive given the shift in surgical paradigm towards minimally invasive surgery. This novel three-channel articulated robot was developed to overcome the limitations of the flexible endoscope which poses a number of challenges to endoluminal surgery. The device enables enhanced movement in a restricted workspace, with improved range of motion and with the accuracy required for endoluminal surgery. To evaluate a novel flexible robot for therapeutic endoluminal surgery. Bench-top studies. Research laboratory. Targeting and navigation tasks of the robot were performed to explore the range of motion and retroflexion capabilities. Complex endoluminal tasks such as endoscopic mucosal resection were also simulated. Successful completion, accuracy and time to perform the bench-top tasks were the main outcome measures. The robot ranges of movement, retroflexion and navigation capabilities were demonstrated. The device showed significantly greater accuracy of targeting in a retroflexed position compared to a conventional endoscope. Bench-top study and small study sample. We were able to demonstrate a number of simulated endoscopy tasks such as navigation, targeting, snaring and retroflexion. The improved accuracy of targeting whilst in a difficult configuration is extremely promising and may facilitate endoluminal surgery which has been notoriously challenging with a conventional endoscope.
Integrated Liquid Bismuth Propellant Feed System
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Markusic, Thomas E.; Stanojev, Boris J.
2006-01-01
A prototype bismuth propellant feed and control system was constructed and tested. An electromagnetic pump was used in this system to provide fine control of the hydrostatic pressure, and a new type of in-line flow sensor was developed to provide an accurate, real-time measurement of the mass flow rate. High-temperature material compatibility was a driving design requirement for the pump and flow sensor, leading to the selection of macor for the main body of both components. Post-test inspections of both components revealed no cracks or leaking in either. In separate proof-of-concept experiments, the pump produced a linear pressure rise as a function of current that compared favorably with theoretical pump pressure predictions, with a pressure of 10 kPa at 30 A. Flow sensing was successfully demonstrated in a bench-top test using gallium as a substitute liquid metal. A real-time controller was successfully used to control the entire system, simultaneously monitoring all power supplies and performing data acquisition duties.
Flexible deep brain neural probes based on a parylene tube structure
NASA Astrophysics Data System (ADS)
Zhao, Zhiguo; Kim, Eric; Luo, Hao; Zhang, Jinsheng; Xu, Yong
2018-01-01
Most microfabricated neural probes have limited shank length, which prevents them from reaching many deep brain structures. This paper reports deep brain neural probes with ultra-long penetrating shanks based on a simple but novel parylene tube structure. The mechanical strength of the parylene tube shank is temporarily enhanced during implantation by inserting a metal wire. The metal wire can be removed after implantation, making the implanted probe very flexible and thus minimizing the stress caused by micromotions of brain tissues. Optogenetic stimulation and chemical delivery capabilities can be potentially integrated by taking advantage of the tube structure. Single-shank prototypes with a shank length of 18.2 mm have been developed. The microfabrication process comprises of deep reactive ion etching (DRIE) of silicon, parylene conformal coating/refilling, and XeF2 isotropic silicon etching. In addition to bench-top insertion characterization, the functionality of developed probes has been preliminarily demonstrated by implanting into the amygdala of a rat and recording neural signals.
Cordray, Michael S; Richards-Kortum, Rebecca R
2015-11-26
Isothermal amplification techniques are emerging as a promising method for malaria diagnosis since they are capable of detecting extremely low concentrations of parasite target while mitigating the need for infrastructure and training required by other nucleic acid based tests. Recombinase polymerase amplification (RPA) is promising for further development since it operates in a short time frame (<30 min) and produces a product that can be visually detected on a lateral flow dipstick. A self-sealing paper and plastic system that performs both the amplification and detection of a malaria DNA sequence is presented. Primers were designed using the NCBI nBLAST tools and screened using gel electrophoresis. Paper and plastic devices were prototyped using commercial design software and parts were cut using a laser cutter and assembled by hand. Synthetic copies of the Plasmodium 18S gene were spiked into solution and used as targets for the RPA reaction. To test the performance of the device the same samples spiked with synthetic target were run in parallel both in the paper and plastic devices and using conventional bench top methods. Novel RPA primers were developed that bind to sequences present in the four species of Plasmodium which infect humans. The paper and plastic devices were found to be capable of detecting as few as 5 copies/µL of synthetic Plasmodium DNA (50 copies total), comparable to the same reaction run on the bench top. The devices produce visual results in an hour, cost approximately $1, and are self-contained once the device is sealed. The device was capable of carrying out the RPA reaction and detecting meaningful amounts of synthetic Plasmodium DNA in a self-sealing and self-contained device. This device may be a step towards making nucleic acid tests more accessible for malaria detection.
Bench-top endomicroscope for visualization and imaging of nuclei using ultraviolet autofluorescence
NASA Astrophysics Data System (ADS)
Lin, Bevin
The long range goal of this research was to develop autofluorescence technology and instrumentation for transition towards an in vivo endomicroscopy imaging system. This approach would provide resolution sufficient to image nuclei for real-time categorization of normal and abnormal tissue implicative of disease progression. Esophageal adenocarcinoma was the chosen model to develop this diagnostic imaging system because the heterogeneous and multifocal nature of this disease makes early diagnosis extremely challenging during the window of time when the prognosis for survival is high. The asymptomatic character of this disease generally presents at a malignant stage when removal of the esophagus has become the standard treatment. The traditional gold standard of histologic diagnosis suffers from a slow turn-around-time from tissue removal to microscopic observation, compounded by error in random biopsy sampling and tissue-processing artifacts, in addition to significant variation in pathologist diagnosis. Optical biopsy has thus been developed to alleviate the problems associated with current standard video endoscopy and histopathology. Following tremendous research in the realm of optical biopsy, some traction has been gained using confocal endomicroscopy. However, current confocal methods require contrast agents and optical sectioning in order to provide images at a cellular level. We have developed a minimally invasive imaging system using autofluorescence that highlights the short photon penetration depth of ultraviolet excitation. This approach provides cellular level resolution with a clinically relevant field of view without requiring contrast agents or optical sectioning. Optical histopathology has been demonstrated using unprocessed ex vivo human gastrointestinal tissues providing diagnostic assessment in real-time, a function imperative for improved patient care and quality of life. This robust bench-top prototype endomicroscopy system is capable of rapid throughput, high sensitivity and specificity, provides a user friendly interface, and preserves distinct advantages in cost based on instrumentation simplicity. These advantages poise this ultraviolet autofluorescence endomicroscopy system for break-through clinical implementation.
Development and marketing of a prosthetic urinary control valve system
NASA Technical Reports Server (NTRS)
Tenney, J. B., Jr.; Rabinowitz, R.; Rogers, D. W.; Harrison, H. N.
1983-01-01
An implantable prosthetic for the control of urinary incontinence was developed and marketed. Three phases are presented: bench development studies, animal trials, and human clinical trials. This work was performed under the direction of a Research Team at Rochester General Hospital (RGH). Bench trials were completed on prototype hardware and provided early verification of the device's ability to withstand repeated cyclic testing. Configurational variants were evaluated and a preferred design concept was established. Silicone rubber (medical grade) was selected as the preferred material for the prosthesis.
Using mini-rockwool blocks as growing media for limited-cluster tomato production
NASA Technical Reports Server (NTRS)
Logendra, L. S.; Gianfagna, T. J.; Janes, H. W.
2001-01-01
Rockwool is an excellent growing medium for the hydroponic production of tomato; however, the standard size rockwool blocks [4 x 4 x 2.5 inches (10 x 10 x 6.3 cm) or 3 x 3 x 2.5 inches (7.5 x 7.5 x 6.3 cm)] are expensive. The following experiments were conducted with less expensive minirock wool blocks (MRBs), on rayon polyester material (RPM) as a bench top liner, to reduce the production cost of tomatoes (Lycopersicon esculentum) grown in a limited-cluster, ebb and flood hydroponic cultivation system. Fruit yield for single-cluster plants growing in MRBs [2 x 2 x 1.6 inches (5 x 5 x 4 cm) and 1.6 x 1.6 x 1.6 inches (4 x 4 x 4 cm)] was not significantly different from plants grown in larger sized blocks (3 x 3 x 2.5 inches). When the bench top was lined with RPM, roots penetrated the RPM, and an extensive root mat developed between the RPM and the bench top. The fruit yield from plants on RPM was significantly increased compared to plants without RPM due to increases in fruit size and fruit number. RPM also significantly reduced the incidence of blossom-end rot. In a second experiment, single- and double-cluster plants were grown on RPM. Fruit yield for double-cluster plants was 40% greater than for single-cluster plants due to an increase in fruit number, although the fruit were smaller in size. As in the first experiment, fruit yield for all plants grown in MRBs was not significantly different from plants grown in the larger sized blocks. MRBs and a RPM bench liner are an effective combination in the production of limited-cluster hydroponic tomatoes.
ELECTROCHEMICAL ARSENIC REMEDIATION IN RURAL BANGLADESH
In Year 1, we built a bench-scale continuous flow prototype (dubbed “Sushi” for its sushi-like electrode roll) and completed preliminary field trials in Bangladesh. We were also able to leverage additional funding to complete preliminary field trials in arsenic-...
SP2Bench: A SPARQL Performance Benchmark
NASA Astrophysics Data System (ADS)
Schmidt, Michael; Hornung, Thomas; Meier, Michael; Pinkel, Christoph; Lausen, Georg
A meaningful analysis and comparison of both existing storage schemes for RDF data and evaluation approaches for SPARQL queries necessitates a comprehensive and universal benchmark platform. We present SP2Bench, a publicly available, language-specific performance benchmark for the SPARQL query language. SP2Bench is settled in the DBLP scenario and comprises a data generator for creating arbitrarily large DBLP-like documents and a set of carefully designed benchmark queries. The generated documents mirror vital key characteristics and social-world distributions encountered in the original DBLP data set, while the queries implement meaningful requests on top of this data, covering a variety of SPARQL operator constellations and RDF access patterns. In this chapter, we discuss requirements and desiderata for SPARQL benchmarks and present the SP2Bench framework, including its data generator, benchmark queries and performance metrics.
NASA Astrophysics Data System (ADS)
David, Sabrina; Burion, Steve; Tepe, Alan; Wilfley, Brian; Menig, Daniel; Funk, Tobias
2012-03-01
Iterative reconstruction methods have emerged as a promising avenue to reduce dose in CT imaging. Another, perhaps less well-known, advance has been the development of inverse geometry CT (IGCT) imaging systems, which can significantly reduce the radiation dose delivered to a patient during a CT scan compared to conventional CT systems. Here we show that IGCT data can be reconstructed using iterative methods, thereby combining two novel methods for CT dose reduction. A prototype IGCT scanner was developed using a scanning beam digital X-ray system - an inverse geometry fluoroscopy system with a 9,000 focal spot x-ray source and small photon counting detector. 90 fluoroscopic projections or "superviews" spanning an angle of 360 degrees were acquired of an anthropomorphic phantom mimicking a 1 year-old boy. The superviews were reconstructed with a custom iterative reconstruction algorithm, based on the maximum-likelihood algorithm for transmission tomography (ML-TR). The normalization term was calculated based on flat-field data acquired without a phantom. 15 subsets were used, and a total of 10 complete iterations were performed. Initial reconstructed images showed faithful reconstruction of anatomical details. Good edge resolution and good contrast-to-noise properties were observed. Overall, ML-TR reconstruction of IGCT data collected by a bench-top prototype was shown to be viable, which may be an important milestone in the further development of inverse geometry CT.
NASA Astrophysics Data System (ADS)
Anderson, F. S.; Nowicki, K.; Whitaker, T.
This paper reports on the first rubidium-strontium (Rb-Sr) radiometric dates using a Laser Desorption Resonance Ionization Mass Spectrometry (LDRIMS) instrument capable of being miniaturized for flight to another planet. The LDRIMS instrument produces dates in under 24 hours, requires minimal sample preparation, and avoids the interference and mass resolution issues associated with other geochronology measurements. We have begun testing the bench-top prototype on the Boulder Creek Granite (BCG), from Colorado, comprised primarily of a gneissic quartz monzonite and granodiorite; whole rock Rb-Sr TIMS measurements result in dates of 1700± 40 Ma [1]. Data reduction of the LDRIMS Rb-Sr measurements on calibrated repeat runs result in a date for the BCG of 1.727± 0.087 Ga (n=288, MSWD=1). Most geochronology applications are willing to accept an MSWD up to ~2.7; at MSWD=2, the precision improves to ± 0.062 Ga. This technology is moving from lab prototype to field deployable instrument, and provides an opportunity to directly address the science goals of Mars Sample Return (MSR) within the bounds posed by current scientific, fiscal, and political pressures on the Mars program. Additionally, LDRIMS could potentially be flown to the Moon under the Discovery or New Frontiers program. We posit that in-situ geochronology missions to Mars to triage and validate samples for Mars Sample Return (MSR) are technically feasible in the 2018-2022 time frame.
AnaBench: a Web/CORBA-based workbench for biomolecular sequence analysis
Badidi, Elarbi; De Sousa, Cristina; Lang, B Franz; Burger, Gertraud
2003-01-01
Background Sequence data analyses such as gene identification, structure modeling or phylogenetic tree inference involve a variety of bioinformatics software tools. Due to the heterogeneity of bioinformatics tools in usage and data requirements, scientists spend much effort on technical issues including data format, storage and management of input and output, and memorization of numerous parameters and multi-step analysis procedures. Results In this paper, we present the design and implementation of AnaBench, an interactive, Web-based bioinformatics Analysis workBench allowing streamlined data analysis. Our philosophy was to minimize the technical effort not only for the scientist who uses this environment to analyze data, but also for the administrator who manages and maintains the workbench. With new bioinformatics tools published daily, AnaBench permits easy incorporation of additional tools. This flexibility is achieved by employing a three-tier distributed architecture and recent technologies including CORBA middleware, Java, JDBC, and JSP. A CORBA server permits transparent access to a workbench management database, which stores information about the users, their data, as well as the description of all bioinformatics applications that can be launched from the workbench. Conclusion AnaBench is an efficient and intuitive interactive bioinformatics environment, which offers scientists application-driven, data-driven and protocol-driven analysis approaches. The prototype of AnaBench, managed by a team at the Université de Montréal, is accessible on-line at: . Please contact the authors for details about setting up a local-network AnaBench site elsewhere. PMID:14678565
NASA Astrophysics Data System (ADS)
Maniowski, M.; Para, S.; Knapczyk, M.
2016-09-01
This paper presents a modernization approach of a standard test bench for determination of damping characteristics of automotive shock absorbers. It is known that the real-life work conditions of wheel-suspension dampers are not easy to reproduce in laboratory conditions, for example considering a high frequency damper response or a noise emission. The proposed test bench consists of many elements from a real vehicle suspension. Namely, an original tyre-wheel with additional unsprung mass, a suspension spring, an elastic top mount, damper bushings and a simplified wheel guiding mechanism. Each component was tested separately in order to identify its mechanical characteristics. The measured data serve as input parameters for a numerical simulation of the test bench behaviour by using a vibratory model with 3 degrees of freedom. Study on the simulation results and the measurements are needed for further development of the proposed test bench.
Banaszek, Daniel; You, Daniel; Chang, Justues; Pickell, Michael; Hesse, Daniel; Hopman, Wilma M; Borschneck, Daniel; Bardana, Davide
2017-04-05
Work-hour restrictions as set forth by the Accreditation Council for Graduate Medical Education (ACGME) and other governing bodies have forced training programs to seek out new learning tools to accelerate acquisition of both medical skills and knowledge. As a result, competency-based training has become an important part of residency training. The purpose of this study was to directly compare arthroscopic skill acquisition in both high-fidelity and low-fidelity simulator models and to assess skill transfer from either modality to a cadaveric specimen, simulating intraoperative conditions. Forty surgical novices (pre-clerkship-level medical students) voluntarily participated in this trial. Baseline demographic data, as well as data on arthroscopic knowledge and skill, were collected prior to training. Subjects were randomized to 5-week independent training sessions on a high-fidelity virtual reality arthroscopic simulator or on a bench-top arthroscopic setup, or to an untrained control group. Post-training, subjects were asked to perform a diagnostic arthroscopy on both simulators and in a simulated intraoperative environment on a cadaveric knee. A more difficult surprise task was also incorporated to evaluate skill transfer. Subjects were evaluated using the Global Rating Scale (GRS), the 14-point arthroscopic checklist, and a timer to determine procedural efficiency (time per task). Secondary outcomes focused on objective measures of virtual reality simulator motion analysis. Trainees on both simulators demonstrated a significant improvement (p < 0.05) in arthroscopic skills compared with baseline scores and untrained controls, both in and ex vivo. The virtual reality simulation group consistently outperformed the bench-top model group in the diagnostic arthroscopy crossover tests and in the simulated cadaveric setup. Furthermore, the virtual reality group demonstrated superior skill transfer in the surprise skill transfer task. Both high-fidelity and low-fidelity simulation trainings were effective in arthroscopic skill acquisition. High-fidelity virtual reality simulation was superior to bench-top simulation in the acquisition of arthroscopic skills, both in the laboratory and in vivo. Further clinical investigation is needed to interpret the importance of these results.
Advance prototype silver ion water bactericide system
NASA Technical Reports Server (NTRS)
Jasionowski, W. J.; Allen, E. T.
1974-01-01
An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.
A clinical decision support system prototype for cardiovascular intensive care.
Lau, F
1994-08-01
This paper describes the development and validation of a decision-support system prototype that can help manage hypovolemic hypotension in the Cardiovascular Intensive Care Unit (CVICU). The prototype uses physiologic pattern-matching, therapeutic protocols, computational drug-dosage response modeling and expert reasoning heuristics in its selection of intervention strategies and choices. As part of model testing, the prototype simulated real-time operation by processing historical physiologic and intervention data on a patient sequentially, generating alerts on questionable data, critiques of interventions instituted and recommendations on preferred interventions. Bench-testing with 399 interventions from 13 historical cases showed therapies for bleeding and fluid replacement proposed by the prototype were significantly more consistent (p < 0.0001) than those instituted by the staff when compared against expert critiques (80% versus 44%). This study has demonstrated the feasibility of formalizing hemodynamic management of CVICU patients in a manner that may be implemented and evaluated in a clinical setting.
Development of an Active Twist Rotor for Wind: Tunnel Testing (NLPN97-310
NASA Technical Reports Server (NTRS)
Cesnik, Carlos E. S.; Shin, SangJoon; Hagood, Nesbitt W., IV
1998-01-01
The development of the Active Twist Rotor prototype blade for hub vibration and noise reduction studies is presented in this report. Details of the modeling, design, and manufacturing are explored. The rotor blade is integrally twisted by direct strain actuation. This is accomplished by distributing embedded piezoelectric fiber composites along the span of the blade. The development of the analysis framework for this type of active blade is presented. The requirements for the prototype blade, along with the final design results are also presented. A detail discussion on the manufacturing aspects of the prototype blade is described. Experimental structural characteristics of the prototype blade compare well with design goals, and preliminary bench actuation tests show lower performance than originally predicted. Electrical difficulties with the actuators are also discussed. The presented prototype blade is leading to a complete fully articulated four-blade active twist rotor system for future wind tunnel tests.
Determination of solvents permeating through chemical protective clothing with a microsensor array.
Park, J; Zellers, E T
2000-08-01
The performance of a novel prototype instrument in determining solvents and solvent mixtures permeating through samples of chemical protective clothing (CPC) materials was evaluated. The instrument contains a mini-preconcentrator and an array of three polymer-coated surface-acoustic-wave (SAW) microsensors whose collective response patterns are used to discriminate among multiple permeants. Permeation tests were performed with a 2.54 cm diameter test cell in an open-loop configuration on samples of common glove materials challenged with four individual solvents, three binary mixtures, and two ternary mixtures. Breakthrough times, defined as the times required for the permeation rate to reach a value of 1 microg cm(-2) min(-1), determined by the instrument were within 3 min of those determined in parallel by manual sampling and gas chromatographic analysis. Permeating solvents were recognized (identified) from their response patterns in 59 out of 64 measurements (92%) and their vapor concentrations were quantified to an accuracy of +/- 31% (typically +/- 10%). These results demonstrate the potential for such instrumentation to provide semi-automated field or bench-top screening of CPC permeation resistance.
NASA Technical Reports Server (NTRS)
Varaljay-Spence, Vanessa A.; Scardelletti, Maximilian C.
2007-01-01
This article discusses the development of a bench-top technique to detect antigens in fluids. The technique involves the use of near infrared NIR fluorescent dyes conjugated to antibodies, centrifugation, nanofilters, and spectrometry. The system used to detect the antigens utilizes a spectrometer, fiber optic cables, NIR laser, and laptop computer thus making it portable and ideally suited for desk top analysis. Using IgM as an antigen and the secondary antibody, anti-IgM conjugated to the near infrared dye, IRDye (trademark) 800, for detection, we show that nanofiltration can efficiently and specifically separate antibody-antigen complexes in solution and that the complexes can be detected by a spectrometer and software using NIR laser excitation at 778 nm and NIR dye offset emission at 804 nm. The peak power detected at 778 nm for the excitation emission and at 804 nm for the offset emission is 879 pW (-60.06 dBm) and 35.7 pW (-74.5 dBm), respectively.
Wang, Zhaohui; Witte, Russell S.
2015-01-01
Ultrasound current source density imaging (UCSDI), which has application to the heart and brain, exploits the acoustoelectric (AE) effect and Ohm's law to detect and map an electrical current distribution. In this study, we describe 4-D UCSDI simulations of a dipole field for comparison and validation with bench-top experiments. The simulations consider the properties of the ultrasound pulse as it passes through a conductive medium, the electric field of the injected dipole, and the lead field of the detectors. In the simulation, the lead fields of detectors and electric field of the dipole were calculated by the finite element (FE) method, and the convolution and correlation in the computation of the detected AE voltage signal were accelerated using 3-D fast Fourier transforms. In the bench-top experiment, an electric dipole was produced in a bath of 0.9% NaCl solution containing two electrodes, which injected an ac pulse (200 Hz, 3 cycles) ranging from 0 to 140 mA. Stimulating and recording electrodes were placed in a custom electrode chamber made on a rapid prototype printer. Each electrode could be positioned anywhere on an x-y grid (5 mm spacing) and individually adjusted in the depth direction for precise control of the geometry of the current sources and detecting electrodes. A 1-MHz ultrasound beam was pulsed and focused through a plastic film to modulate the current distribution inside the saline-filled tank. AE signals were simultaneously detected at a sampling frequency of 15 MHz on multiple recording electrodes. A single recording electrode is sufficient to form volume images of the current flow and electric potentials. The AE potential is sensitive to the distance from the dipole, but is less sensitive to the angle between the detector and the dipole. Multi-channel UCSDI potentially improves 4-D mapping of bioelectric sources in the body at high spatial resolution, which is especially important for diagnosing and guiding treatment of cardiac and neurologic disorders, including arrhythmia and epilepsy. PMID:24569247
STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes pinch bar, deadblow hammer, punch, inspection mirror, speed handle assembly, robbins wrench, adjustable wrench, vise grips, connector pliers, ACCU bypass connector, connector strap wrench, locker tool, and mechanical fingers. Photo taken by NASA JSC contract photographer Benny Benavides.
ANAEROBIC AND AEROBIC TREATMENT OF CHLORINATED ALIPHATIC COMPOUNDS
Biological degradation of 12 chlorinated aliphatic compounds (CACs) was assessed in bench-top reactors and in serum bottle tests. Three continuously mixed daily batch-fed reactor systems were evaluated: anaerobic, aerobic, and sequential-anaerobic-aerobic (sequential). Glucose,...
Beta-glucan production by Botryosphaeria rhodina in different bench-top bioreactors.
Selbmann, L; Crognale, S; Petruccioli, M
2004-01-01
Evaluation of the technical feasibility of transferring beta-glucan production by Botryosphaeria rhodina DABAC-P82 from shaken flasks to bench-top bioreactors. Three different bioreactors were used: 3 l stirred tank reactor (STR-1) equipped with two different six-blade turbines; STR as above but equipped with a three-blade marine propeller plus draft-tube (STR-2); 2 l air-lift column reactor (ALR) equipped with an external loop. STR-1, tested at three different stirrer speeds (300, 500 and 700 rev min(-1)) appeared to be less suitable for beta-glucan production by the fungus, being maximum production (19.4 g l(-1)), productivity (0.42 g l(-1) h(-1)) and yield (0.48 g g(-1) of glucose consumed) markedly lower than those obtained in shaken culture (29.7 g l(-1), 1.23 g l(-1) h(-1) and 0.61 g g(-1), respectively). Better performances were obtained with both STR-2 and ALR. With the latter, in particular, the increase of production was accompanied by reduced fermentation time (25.7 g l(-1) after only 22 h); productivity and yield were highest (1.17 g l(-1) h(-1) and 0.62 g g(-1) of glucose consumed, respectively). Using an air-lift reactor with external loop, the scaling up from shaken flasks to bench-top bioreactor of the beta-glucan production by B. rhodina DABAC-P82 is technically feasible. Although culture conditions are still to be optimized, the results obtained using the ARL are highly promising.
Testing of a work bench for handling of explosives in the laboratory
NASA Astrophysics Data System (ADS)
Hank, R.; Johansson, K.; Lagman, L.
1981-01-01
A prototype work station was developed at which jobs can be carried out with explosives up to 10 gr and deflagrating products up to 50 gr. Tests were made to investigate the consequences of a spontaneous accident during work. Conclusions are: the workbench offers good protection against splinters provided the inside walls are coated with a shock absorber; the carbonate glass should be a minimum of eight mm thick; the risk of burns, except on arms and hands, is very low; the bench withstands the explosion with the given weight of explosives (10 gr); the risk of lesions on the lung are very low, for the operator as well as for somebody nearby.
Characterization benches for neutrino telescope Optical Modules at the APC laboratory
NASA Astrophysics Data System (ADS)
Avgitas, Theodore; Creusot, Alexandre; Kouchner, Antoine
2016-04-01
As has been demonstrated by the first generation of neutrino telescopes Antares and IceCube, precise knowledge of the photon detection efficiency of optical modules is of fundamental importance for the understanding of the instrument and accurate event reconstruction. Dedicated test benches have been developed to measure all related quantities for the Digital Optical Modules of the KM3NeT neutrino telescope being currently deployed in the Mediterranean sea. The first bench is a black box with robotic arms equipped with a calibrated single photon source or laser which enable a precise mapping of the detection efficiency at arbitrary incident angles as well as precise measurements of the time delays induced by the photodetection chain. These measurement can be incorporated and compared to full GEANT MonteCarlo simulations of the optical modules. The second bench is a 2 m×2 m ×2 m water tank equipped with muon hodoscopes on top and bottom. It enables to study and measure the angular dependence of the DOM's detection efficiency of the Cherenkov light produced in water by relativistic muons, thus reproducing in situ detection conditions. We describe these two benches and present their first results and status.
Reliability of Triaxial Accelerometry for Measuring Load in Men's Collegiate Ice Hockey.
Van Iterson, Erik H; Fitzgerald, John S; Dietz, Calvin C; Snyder, Eric M; Peterson, Ben J
2017-05-01
Van Iterson, EH, Fitzgerald, JS, Dietz, CC, Snyder, EM, and Peterson, BJ. Reliability of triaxial accelerometry for measuring load in men's collegiate ice hockey. J Strength Cond Res 31(5): 1305-1312, 2017-Wearable microsensor technology incorporating triaxial accelerometry is used to quantify an index of mechanical stress associated with sport-specific movements termed PlayerLoad. The test-retest reliability of PlayerLoad in the environmental setting of ice hockey is unknown. The primary aim of this study was to quantify the test-retest reliability of PlayerLoad in ice hockey players during performance of tasks simulating game conditions. Division I collegiate male ice hockey players (N = 8) wore Catapult Optimeye S5 monitors during repeat performance of 9 ice hockey tasks simulating game conditions. Ordered ice hockey tasks during repeated bouts included acceleration (forward or backward), 60% top-speed, top-speed (forward or backward), repeated shift circuit, ice coasting, slap shot, and bench sitting. Coefficient of variation (CV), intraclass correlation coefficient (ICC), and minimum difference (MD) were used to assess PlayerLoad reliability. Test-retest CVs and ICCs of PlayerLoad were as follows: 8.6% and 0.54 for forward acceleration, 13.8% and 0.78 for backward acceleration, 2.2% and 0.96 for 60% top-speed, 7.5% and 0.79 for forward top-speed, 2.8% and 0.96 for backward top-speed, 26.6% and 0.95 for repeated shift test, 3.9% and 0.68 for slap shot, 3.7% and 0.98 for coasting, and 4.1% and 0.98 for bench sitting, respectively. Raw differences between bouts were not significant for ice hockey tasks (p > 0.05). For each task, between-bout raw differences were lower vs. MD: 0.06 vs. 0.35 (forward acceleration), 0.07 vs. 0.36 (backward acceleration), 0.00 vs. 0.06 (60% top-speed), 0.03 vs. 0.20 (forward top-speed), 0.02 vs. 0.09 (backward top-speed), 0.18 vs. 0.64 (repeated shift test), 0.02 vs. 0.10 (slap shot), 0.00 vs. 0.10 (coasting), and 0.01 vs. 0.11 (bench sitting), respectively. These data suggest that PlayerLoad demonstrates moderate-to-large test-retest reliability in the environmental setting of male Division I collegiate ice hockey. Without previously testing reliability, these data are important as PlayerLoad is routinely quantified in male collegiate ice hockey to assess on ice physical activity.
Large format array controller (aLFA-C): tests and characterisation at ESA
NASA Astrophysics Data System (ADS)
Lemmel, Frédéric; ter Haar, Jörg; van der Biezen, John; Duvet, Ludovic; Nelms, Nick; Blommaert, Sander; Butler, Bart; van der Luijt, Cornelis; Heijnen, Jerko; Smit, Hans; Visser, Ivo
2016-08-01
For future near infrared astronomy missions, ESA is developing a complete detection and conversion chain (photon to SpaceWire chain system): Large Format Array (aLFA-N) based on MCT type detectors. aLFA-C (Astronomy Large Format Array Controller): a versatile cryogenic detector controller. An aLFA-C prototype was developed by Caeleste (Belgium) under ESA contract (400106260400). To validate independently the performances of the aLFA-C prototype and consolidate the definition of the follow-on activity, a dedicated test bench has been designed and developed in ESTEC/ESA within the Payload Technology Validation group. This paper presents the test setup and the performance validation of the first prototype of this controller at room and cryogenic temperature. Test setup and software needed to test the HAWAII-2RG and aLFA-N detectors with the aLFA-C prototype at cryogenic temperature will be also presented.
Evaluation of seismic testing for quality assurance of lime-stabilized soil.
DOT National Transportation Integrated Search
2013-08-01
This study sought to determine the technical feasibility of using seismic techniques to measure the : laboratory and field seismic modulus of lime-stabilized soils (LSS), and to compare/correlate test results : from bench-top (free-free resonance) se...
USDA-ARS?s Scientific Manuscript database
This paper, written in Spanish, describes the capture and recovery of gaseous ammonia from turkey manure using gas-permeable membranes technology with formation of stabilized ammonium salts. Bench experiments were carried out in Maryland using a pilot prototype system with turkey litter inside contr...
Latest developments at the ALBA magnetic measurements laboratory
NASA Astrophysics Data System (ADS)
Marcos, J.; Massana, V.; García, L.; Campmany, J.
2018-02-01
ALBA is a third-generation synchrotron light source that has been in operation since 2012 near Barcelona. A magnetic measurements laboratory has been associated with the facility since its very early stages and has been active for the last 20 years. In the first part of this work, the different instruments available at the laboratory are described, and a brief overview of the measurement campaigns carried out during its 20 years of history is presented. In the second part, a more detailed description of the approach to Hall probe measurements adopted at ALBA is offered, with an explanation of the methods and ancillary equipment that have been developed along the years in order to improve the accuracy of the system. In the third part, a new concept of Hall probe bench devoted to the measurement of closed structures is presented. The in-house design and building of a prototype for such a bench is described, together with its mechanical and magnetic characterization. As a conclusion, the first results obtained with this bench are discussed.
An Experiment Using Sucrose Density Gradients in the Undergraduate Biochemistry Laboratory.
ERIC Educational Resources Information Center
Turchi, Sandra L.; Weiss, Monica
1988-01-01
Describes an experiment to be performed in an undergraduate biochemistry laboratory that is based on a gradient centrifugation system employing a simple bench top centrifuge, a freezer, and frozen surcose gradient solution to separate macromolecules and subcellular components. (CW)
USDA-ARS?s Scientific Manuscript database
Forage nutritive value (i.e., forage quality) impacts livestock health and performance, but determining the quality of forages for grazing animals is difficult. In the 1970s, development and application of bench-top near-infrared spectroscopy (NIRS) techniques to assess forage quality proved to be ...
A Classroom Demonstration of Psychrometrics.
ERIC Educational Resources Information Center
Clark, Jim A.; Nikolajczyk, David R.
1983-01-01
Presented is a bench-top demonstration of heating/humidification designed to provide visual confirmation of psychrometric principles outlined in thermodynamics texts. Includes a schematic sketch of the heater/humidifier apparatus, discussion of the six steps involved during the demonstration, and a table of experimental results. (JN)
Design and first plasma measurements of the ITER-ECE prototype radiometer.
Austin, M E; Brookman, M W; Rowan, W L; Danani, S; Bryerton, E W; Dougherty, P
2016-11-01
On ITER, second harmonic optically thick electron cyclotron emission (ECE) in the range of 220-340 GHz will supply the electron temperature (T e ). To investigate the requirements and capabilities prescribed for the ITER system, a prototype radiometer covering this frequency range has been developed by Virginia Diodes, Inc. The first plasma measurements with this instrument have been carried out on the DIII-D tokamak, with lab bench tests and measurements of third through fifth harmonic ECE from high T e plasmas. At DIII-D the instrument shares the transmission line of the Michelson interferometer and can simultaneously acquire data. Comparison of the ECE radiation temperature from the absolutely calibrated Michelson and the prototype receiver shows that the ITER radiometer provides accurate measurements of the millimeter radiation across the instrument band.
Khater, Nazih; Shen, Jim; Arenas, Javier; Keheila, Mohamed; Alsyouf, Muhannad; Martin, Jacob A; Lightfoot, Michelle A; Li, Roger; Olgin, Gaudencio; Smith, Jason C; Baldwin, D Duane
2016-11-01
Traditional techniques for obtaining percutaneous renal access utilize continuous fluoroscopy. In an attempt to minimize radiation exposure, we describe a novel laser direct alignment radiation reduction technique (DARRT) for percutaneous access and test it in a bench-top model. In this randomized-controlled bench-top study, 20 medical personnel obtained renal accesses using both the conventional bullseye technique and the laser DARRT. The primary endpoint was total fluoroscopy time. Secondary endpoints included insertion time, puncture attempts, course corrections, and subjective procedural difficulty. In the laser DARRT, fluoroscopy was used with the C-arm positioned with the laser beam at a 30° angle. The access needle and hub were aligned with the laser beam. Effective caliceal puncture was confirmed with fluoroscopy and direct vision. The Paired samples Wilcoxon signed rank test was used for statistical analysis with significance at p < 0.05. A total of 120 needle placements were recorded. Fluoroscopy time for needle access using the laser DARRT was significantly lower than the bullseye technique in all groups as follows: attendings (7.09 vs 18.51 seconds; p < 0.001), residents (6.55 vs 13.93 seconds; p = 0.001), and medical students (6.69 vs 20.22 seconds; p < 0.001). Students rated the laser DARRT easier to use (2.56 vs 4.89; p < 0.001). No difference was seen in total access time, puncture attempts, or course corrections between techniques. The laser DARRT reduced fluoroscopy time by 63%, compared with the conventional bullseye technique. The least experienced users found the laser DARRT significantly easier to learn. This novel technique is promising and merits additional testing in animal and human models.
Development of an integrated semi-automated system for in vitro pharmacodynamic modelling.
Wang, Liangsu; Wismer, Michael K; Racine, Fred; Conway, Donald; Giacobbe, Robert A; Berejnaia, Olga; Kath, Gary S
2008-11-01
The aim of this study was to develop an integrated system for in vitro pharmacodynamic modelling of antimicrobials with greater flexibility, easier control and better accuracy than existing in vitro models. Custom-made bottle caps, fittings, valve controllers and a modified bench-top shaking incubator were used. A temperature-controlled automated sample collector was built. Computer software was developed to manage experiments and to control the entire system including solenoid pinch valves, peristaltic pumps and the sample collector. The system was validated by pharmacokinetic simulations of linezolid 600 mg infusion. The antibacterial effect of linezolid against multiple Staphylococcus aureus strains was also studied in this system. An integrated semi-automated bench-top system was built and validated. The temperature-controlled automated sample collector allowed unattended collection and temporary storage of samples. The system software reduced the labour necessary for many tasks and also improved the timing accuracy for performing simultaneous actions in multiple parallel experiments. The system was able to simulate human pharmacokinetics of linezolid 600 mg intravenous infusion accurately. A pharmacodynamic study of linezolid against multiple S. aureus strains with a range of MICs showed that the required 24 h free drug AUC/MIC ratio was approximately 30 in order to keep the organism counts at the same level as their initial inoculum and was about > or = 68 in order to achieve > 2 log(10) cfu/mL reduction in the in vitro model. The integrated semi-automated bench-top system provided the ability to overcome many of the drawbacks of existing in vitro models. It can be used for various simple or complicated pharmacokinetic/pharmacodynamic studies efficiently and conveniently.
Corrosion of tungsten microelectrodes used in neural recording applications.
Patrick, Erin; Orazem, Mark E; Sanchez, Justin C; Nishida, Toshikazu
2011-06-15
In neuroprosthetic applications, long-term electrode viability is necessary for robust recording of the activity of neural populations used for generating communication and control signals. The corrosion of tungsten microwire electrodes used for intracortical recording applications was analyzed in a controlled bench-top study and compared to the corrosion of tungsten microwires used in an in vivo study. Two electrolytes were investigated for the bench-top electrochemical analysis: 0.9% phosphate buffered saline (PBS) and 0.9% PBS containing 30 mM of hydrogen peroxide. The oxidation and reduction reactions responsible for corrosion were found by measurement of the open circuit potential and analysis of Pourbaix diagrams. Dissolution of tungsten to form the tungstic ion was found to be the corrosion mechanism. The corrosion rate was estimated from the polarization resistance, which was extrapolated from the electrochemical impedance spectroscopy data. The results show that tungsten microwires in an electrolyte of PBS have a corrosion rate of 300-700 μm/yr. The corrosion rate for tungsten microwires in an electrolyte containing PBS and 30 mM H₂O₂ is accelerated to 10,000-20,000 μm/yr. The corrosion rate was found to be controlled by the concentration of the reacting species in the cathodic reaction (e.g. O₂ and H₂O₂). The in vivo corrosion rate, averaged over the duration of implantation, was estimated to be 100 μm/yr. The reduced in vivo corrosion rate as compared to the bench-top rate is attributed to decreased rate of oxygen diffusion caused by the presence of a biological film and a reduced concentration of available oxygen in the brain. Copyright © 2011 Elsevier B.V. All rights reserved.
Xu, Ping; Clark, Colleen; Ryder, Todd; Sparks, Colleen; Zhou, Jiping; Wang, Michelle; Russell, Reb; Scott, Charo
2017-03-01
Demands for development of biological therapies is rapidly increasing, as is the drive to reduce time to patient. In order to speed up development, the disposable Automated Microscale Bioreactor (Ambr 250) system is increasingly gaining interest due to its advantages, including highly automated control, high throughput capacity, and short turnaround time. Traditional early stage upstream process development conducted in 2 - 5 L bench-top bioreactors requires high foot-print, and running cost. The establishment of the Ambr 250 as a scale-down model leads to many benefits in process development. In this study, a comprehensive characterization of mass transfer coefficient (k L a) in the Ambr 250 was conducted to define optimal operational conditions. Scale-down approaches, including dimensionless volumetric flow rate (vvm), power per unit volume (P/V) and k L a have been evaluated using different cell lines. This study demonstrates that the Ambr 250 generated comparable profiles of cell growth and protein production, as seen at 5-L and 1000-L bioreactor scales, when using k L a as a scale-down parameter. In addition to mimicking processes at large scales, the suitability of the Ambr 250 as a tool for clone selection, which is traditionally conducted in bench-top bioreactors, was investigated. Data show that cell growth, productivity, metabolite profiles, and product qualities of material generated using the Ambr 250 were comparable to those from 5-L bioreactors. Therefore, Ambr 250 can be used for clone selection and process development as a replacement for traditional bench-top bioreactors minimizing resource utilization during the early stages of development in the biopharmaceutical industry. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:478-489, 2017. © 2017 American Institute of Chemical Engineers.
Feasibility study of utilizing ultraportable projectors for endoscopic video display (with videos).
Tang, Shou-Jiang; Fehring, Amanda; Mclemore, Mac; Griswold, Michael; Wang, Wanmei; Paine, Elizabeth R; Wu, Ruonan; To, Filip
2014-10-01
Modern endoscopy requires video display. Recent miniaturized, ultraportable projectors are affordable, durable, and offer quality image display. Explore feasibility of using ultraportable projectors in endoscopy. Prospective bench-top comparison; clinical feasibility study. Masked comparison study of images displayed via 2 Samsung ultraportable light-emitting diode projectors (pocket-sized SP-HO3; pico projector SP-P410M) and 1 Microvision Showwx-II Laser pico projector. BENCH-TOP FEASIBILITY STUDY: Prerecorded endoscopic video was streamed via computer. CLINICAL COMPARISON STUDY: Live high-definition endoscopy video was simultaneously displayed through each processor onto a standard liquid crystal display monitor and projected onto a portable, pull-down projection screen. Endoscopists, endoscopy nurses, and technicians rated video images; ratings were analyzed by linear mixed-effects regression models with random intercepts. All projectors were easy to set up, adjust, focus, and operate, with no real-time lapse for any. Bench-top study outcomes: Samsung pico preferred to Laser pico, overall rating 1.5 units higher (95% confidence interval [CI] = 0.7-2.4), P < .001; Samsung pocket preferred to Laser pico, 3.3 units higher (95% CI = 2.4-4.1), P < .001; Samsung pocket preferred to Samsung pico, 1.7 units higher (95% CI = 0.9-2.5), P < .001. The clinical comparison study confirmed the Samsung pocket projector as best, with a higher overall rating of 2.3 units (95% CI = 1.6-3.0), P < .001, than Samsung pico. Low brightness currently limits pico projector use in clinical endoscopy. The pocket projector, with higher brightness levels (170 lumens), is clinically useful. Continued improvements to ultraportable projectors will supply a needed niche in endoscopy through portability, reduced cost, and equal or better image quality. © The Author(s) 2013.
Letzen, Brian; Park, Jiheum; Tuzun, Zeynep; Bonde, Pramod
The current left ventricular assist devices (LVADs) are limited by a highly invasive implantation procedure in a severely unstable group of advanced heart failure patients. Additionally, the current transcutaneous power drive line acts as a nidus for infection resulting in significant morbidity and mortality. In an effort to decrease this invasiveness and eliminate drive line complications, we have conceived a wireless miniaturized percutaneous LVAD, capable of being delivered endovascularly with a tether-free operation. The system obviates the need for a transcutaneous fluid purge line required in existing temporary devices by utilizing an incorporated magnetically coupled impeller for a complete seal. The objective of this article was to demonstrate early development and proof-of-concept feasibility testing to serve as the groundwork for future formalized device development. Five early prototypes were designed and constructed to iteratively minimize the pump size and improve fluid dynamic performance. Various magnetic coupling configurations were tested. Using SolidWorks and ANSYS software for modeling and simulation, several geometric parameters were varied. HQ curves were constructed from preliminary in vitro testing to characterize the pump performance. Bench top tests showed no-slip magnetic coupling of the impeller to the driveshaft up to the current limit of the motor. The pump power requirements were tested in vitro and were within the appropriate range for powering via a wireless energy transfer system. Our results demonstrate the proof-of-concept feasibility of a novel endovascular cardiac assist device with the potential to eventually offer patients an untethered, minimally invasive support.
DOT National Transportation Integrated Search
2014-08-01
A proof of concept was established for a sensor capable of using indirect impedance spectroscopy to : detect the existence of corrosion in post-tensioned tendons. This development was supported by a : combination of bench-top experiments performed on...
Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters
Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.
2016-01-01
Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170
NASA Astrophysics Data System (ADS)
McIntosh, Bryan
The LSO scintillator crystal commonly used in PET scanners contains a low level of intrinsic radioactivity due to a small amount of Lu-176. This is not usually a concern in routine scanning but can become an issue in small animal imaging, especially when imaging low tracer activity levels. Previously there had been no systematic validation of simulations of this activity; this thesis discusses the validation of a GATE model of intrinsic Lu-176 against results from a bench-top pair of detectors and a Siemens Inveon preclinical PET system. The simulation results matched those from the bench-top system very well, but did not agree as well with results from the complete Inveon system due to a drop-off in system sensitivity at low energies that was not modelled. With this validation the model can now be used with confidence to predict the effects of Lu-176 activity in future PET systems.
Active coherent laser spectrometer for remote detection and identification of chemicals
NASA Astrophysics Data System (ADS)
MacLeod, Neil A.; Weidmann, Damien
2012-10-01
Currently, there exists a capability gap for the remote detection and identification of threat chemicals. We report here on the development of an Active Coherent Laser Spectrometer (ACLaS) operating in the thermal infrared and capable of multi-species stand-off detection of chemicals at sub ppm.m levels. A bench top prototype of the instrument has been developed using distributed feedback mid-infrared quantum cascade lasers as spectroscopic sources. The instrument provides active eye-safe illumination of a topographic target and subsequent spectroscopic analysis through optical heterodyne detection of the diffuse backscattered field. Chemical selectivity is provided by the combination of the narrow laser spectral bandwidth (typically < 2 MHz) and frequency tunability that allows the recording of the full absorption spectrum of any species within the instrument line of sight. Stand-off detection at distances up to 12 m has been demonstrated on light molecules such as H2O, CH4 and N2O. A physical model of the stand-off detection scenario including ro-vibrational molecular absorption parameters was used in conjunction with a fitting algorithm to retrieve quantitative mixing ratio information on multiple absorbers.
A prototype gas exchange monitor for exercise stress testing aboard NASA Space Station
NASA Technical Reports Server (NTRS)
Orr, Joseph A.; Westenskow, Dwayne R.; Bauer, Anne
1989-01-01
This paper describes an easy-to-use monitor developed to track the weightlessness deconditioning aboard the NASA Space Station, together with the results of testing of a prototype instrument. The monitor measures the O2 uptake and CO2 production, and calculates the maximum O2 uptake and anaerobic threshold during an exercise stress test. The system uses two flowmeters in series to achieve a completely automatic calibration, and uses breath-by-breath compensation for sample line-transport delay. The monitor was evaluated using two laboratory methods and was shown to be accurate. The system's block diagram and the bench test setup diagram are included.
Recovery of residue tops in selectively cut northern hardwood stands.
James A. Johnson; Rodger A. Arola; Edwin S. Miyata
1982-01-01
Tests the feasibility and economics of compacting hardwood tops with a prototype shearing and bunching device prior to skidding. Presents productivity levels and costs associated with compacting, skidding, and chipping hardwood tops.
Broyer, Patrick; Perrot, Nadine; Rostaing, Hervé; Blaze, Jérome; Pinston, Frederic; Gervasi, Gaspard; Charles, Marie-Hélène; Dachaud, Fabien; Dachaud, Jacques; Moulin, Frederic; Cordier, Sylvain; Dauwalder, Olivier; Meugnier, Hélène; Vandenesch, Francois
2018-01-01
Sepsis is the leading cause of death among patients in intensive care units (ICUs) requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID) of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek ® MS slides directly from positive blood culture broth based on an "all-in-one" extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT ® 3D (SA/SN blood culture bottles) or the BacT/ALERT Virtuo TM system (FA/FN Plus bottles), respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100%) when used with BacT/ALERT ® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75%) with Virtuo ® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%), demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could potentially be improved by converting direct ID of positive blood cultures from a batch-based to real-time and "on-demand" process.
Design and first plasma measurements of the ITER-ECE prototype radiometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Austin, M. E.; Brookman, M. W.; Rowan, W. L.
2016-11-15
On ITER, second harmonic optically thick electron cyclotron emission (ECE) in the range of 220-340 GHz will supply the electron temperature (T{sub e}). To investigate the requirements and capabilities prescribed for the ITER system, a prototype radiometer covering this frequency range has been developed by Virginia Diodes, Inc. The first plasma measurements with this instrument have been carried out on the DIII-D tokamak, with lab bench tests and measurements of third through fifth harmonic ECE from high T{sub e} plasmas. At DIII-D the instrument shares the transmission line of the Michelson interferometer and can simultaneously acquire data. Comparison of themore » ECE radiation temperature from the absolutely calibrated Michelson and the prototype receiver shows that the ITER radiometer provides accurate measurements of the millimeter radiation across the instrument band.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yow, T.G.
The Transportation Operational Personal Property Standard System (TOPS) is an automated information management system to help administer the personal property transporation program for the Department of Defense (DOD). TOPS was fielded at four prototype sites in the late summer of 1988. Prototype testing is currently underway, with system deployment scheduled for 1989. When fully deployed, TOPS will save DOD both time and money and help ensure that all shipments made by armed services personnel are handled quickly and efficiently. The success of the TOPS system depends upon several key factors. Of course, TOPS must give transportation clerks at military personalmore » property shipping offices a tool with which they can perform their jobs with greater ease, speed, and correctness. However, before TOPS can achieve success in the field, it must first find acceptance from the transportation clerks themselves. The purpose of this document is to examine the user interface techniques used in the Counseling module of TOPS to ensure user acceptance and data base integrity, both key elements in the ultimate success of TOPS. 6 refs., 12 figs.« less
Tactile Sensing Reflexes for Advanced Prosthetic Hands
2016-10-01
mos.) 100% • Design and build “mechanical egg ” test equipment (1-2 mos.) (Abandoned, alternate approach developed) • Develop experimental protocol...of a “mechanical egg ” or force measuring object was rejected in favor of this common cracker. Page 6 • A comprehensive bench top study was
Coke Accumulation on Catalysts used in a Fluidized Bed Pyrolyzer
USDA-ARS?s Scientific Manuscript database
We have examined the impact of various solid catalysts on the product distribution resulting from the pyrolysis of biomass. Though catalysts do have a discernible impact, this impact is small. In our bench-top pyrolyzer designed as a catalyst screening tool, we measure bulk product distribution as...
DEVELOPMENT OF AN AFFORDABLE FAMILY-SCALE BIOGAS GENERATOR
From laboratory experiments we calculated that our system would have to deliver 262 liters/hr of biogas to cook a meal. Biogas produced by slurries of various wastes was measured with a two liter bench-top digester system designed by the team. Gas volume was measured by displa...
International Space Station Alpha (ISSA) Integrated Traffic Model
NASA Technical Reports Server (NTRS)
Gates, Robert E.
1994-01-01
The paper discusses the development process of the International Space Station Alpha (ISSA) Integrated Traffic Model which is a subsystem analyses tool utilized in the ISSA design analysis cycles. Fast-track prototyping of the detailed relationships between daily crew and station consumables, propellant needs, maintenance requirements, and crew rotation via spread sheets provides adequate bench marks to assess cargo vehicle design and performance characteristics.
Physical Characteristics and Performance of Japanese Top-Level American Football Players.
Yamashita, Daichi; Asakura, Masaki; Ito, Yoshihiko; Yamada, Shinzo; Yamada, Yosuke
2017-09-01
Yamashita, D, Asakura, M, Ito, Y, Yamada, S, and Yamada, Y. Physical characteristics and performance of Japanese top-level American football players. J Strength Cond Res 31(9): 2455-2461, 2017-This study aimed to compare the physical characteristics and performance between top-level nonprofessional football players in Japan and National Football League (NFL) Combine invited players and between top-level and middle-level players in Japan to determine the factors that enhance performance in international and national competitions. A total of 168 American football players (>20 years) in Japan participated in an anthropometric (height and weight) and physical (vertical jump, long jump, 40-yard dash, pro-agility shuttle, 3-cone drill, and bench press repetition test) measurement program based on the NFL Combine program to compete in the selection of candidates for the Senior World Championship. All players were categorized into 1 of the 3 position groups based on playing position: skill players, big skill players, and linemen. Japanese players were additionally categorized into selected and nonselected players for the second tryout. The NFL Combine candidates had significantly better performance than selected Japanese players on all variables except on performance related to quickness among the 3 position groups. Compared with nonselected players, selected Japanese skill players had better performance in the 40-yard dash and bench press test and big skill players had better performance in the vertical jump, broad jump, and 40-yard dash. Selected and nonselected Japanese linemen were not different in any measurements. These results showed the challenges in American football in Japan, which include not only improving physical performance of top-level players, but also increasing the number of football players with good physical performance.
Physical Characteristics and Performance of Japanese Top-Level American Football Players
Asakura, Masaki; Ito, Yoshihiko; Yamada, Shinzo; Yamada, Yosuke
2017-01-01
Abstract Yamashita, D, Asakura, M, Ito, Y, Yamada, S, and Yamada, Y. Physical characteristics and performance of Japanese top-level American football players. J Strength Cond Res 31(9): 2455–2461, 2017—This study aimed to compare the physical characteristics and performance between top-level nonprofessional football players in Japan and National Football League (NFL) Combine invited players and between top-level and middle-level players in Japan to determine the factors that enhance performance in international and national competitions. A total of 168 American football players (>20 years) in Japan participated in an anthropometric (height and weight) and physical (vertical jump, long jump, 40-yard dash, pro-agility shuttle, 3-cone drill, and bench press repetition test) measurement program based on the NFL Combine program to compete in the selection of candidates for the Senior World Championship. All players were categorized into 1 of the 3 position groups based on playing position: skill players, big skill players, and linemen. Japanese players were additionally categorized into selected and nonselected players for the second tryout. The NFL Combine candidates had significantly better performance than selected Japanese players on all variables except on performance related to quickness among the 3 position groups. Compared with nonselected players, selected Japanese skill players had better performance in the 40-yard dash and bench press test and big skill players had better performance in the vertical jump, broad jump, and 40-yard dash. Selected and nonselected Japanese linemen were not different in any measurements. These results showed the challenges in American football in Japan, which include not only improving physical performance of top-level players, but also increasing the number of football players with good physical performance. PMID:28052052
NASA Technical Reports Server (NTRS)
1995-01-01
The purpose of this contract was to provide optomechanical engineering and fabrication support to the Solar X-ray Imager (SXI) program in the areas of mirror, optical bench and camera assemblies of the telescope. The Center for Applied Optics (CAO) worked closely with the Optics and S&E technical staff of MSFC to develop and investigate the most viable and economical options for the design and fabrication of a number of parts for the various telescope assemblies. All the tasks under this delivery order have been successfully completed within budget and schedule. A number of development hardware parts have been designed and fabricated jointly by MSFC and UAH for the engineering model of SXI. The major parts include a nickel electroformed mirror and a mirror mount, plating and coating of the ceramic spacers, and gold plating of the contact rings and fingers for the camera assembly. An aluminum model of the high accuracy sun sensor (HASS) was also designed and fabricated. A number of fiber optic tapers for the camera assembly were also coated with indium tin oxide and phosphor for testing and evaluation by MSFC. A large number of the SXI optical bench parts were also redesigned and simplified for a prototype telescope. These parts include the forward and rear support flanges, front aperture plate, the graphite epoxy optical bench and a test fixture for the prototype telescope. More than fifty (50) drawings were generated for various components of the prototype telescope. Some of these parts were subsequently fabricated at UAH machine shop or at MSFC or by the outside contractors. UAH also provide technical support to MSFC staff for a number of preliminary and critical design reviews. These design reviews included PDR and CDR for the mirror assembly by United Technologies Optical Systems (UTOS), and the program quarterly reviews, and SXI PDR and CDR. UAH staff also regularly attended the monthly status reviews, and made a significant number of suggestions to improve the design, assembly and alignment of the telescope. Finally, a high level assembly and alignment plan for the entire telescope was prepared by UAH. This plan addresses the sequence of assembly, the required assembly and alignment tolerances, and the methods to verify the alignment at each step during the assembly process. This assembly and alignment plan will be used to assemble and integrate the engineering model (EM) of the telescope. Later on, based on this plan more detailed assembly and alignment procedures will be developed for the lower-level assemblies of SXI.
STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes modified forceps, L-shaped hex wrenches, jeweler screwdrivers, adjustable wrench, bone saw, combination wrenches, override devices, switch guards, tape measure, torque driver, short screwdriver, long screwdriver, phillips screwdrivers, ratchet wrench, needlenose pliers, torque tips, adapter, universal joint, deepwell sockets, sockets, driver handle, seat adjustment tool, extensions, torque wrench, allen head drivers, hacksaw, and blades. Photo taken by NASA JSC contract photographer Benny Benavides.
Design and first plasma measurements of the ITER-ECE prototype radiometer
Austin, M. E.; Brookman, M. W.; Rowan, W. L.; ...
2016-08-09
On ITER, second harmonic optically thick electron cyclotron emission (ECE) in the range of 220-340 GHz will supply the electron temperature (T e). In order to investigate the requirements and capabilities prescribed for the ITER system, a prototype radiometer covering this frequency range has been developed by Virginia Diodes, Inc. The first plasma measurements with this instrument have been carried out on the DIII-D tokamak, with lab bench tests and measurements of third through fifth harmonic ECE from high T e plasmas. At DIII-D the instrument shares the transmission line of the Michelson interferometer and can simultaneously acquire data. Inmore » our comparison of the ECE radiation temperature from the absolutely calibrated Michelson and the prototype receiver we show that the ITER radiometer provides accurate measurements of the millimeter radiation across the instrument band.« less
Wearable photoplethysmography device prototype for wireless cardiovascular monitoring
NASA Astrophysics Data System (ADS)
Kviesis-Kipge, E.; Grabovskis, A.; Marcinkevics, Z.; Mecnika, V.; Rubenis, O.
2014-05-01
The aim of the study was to develop a prototype system of the smart garment for real time telemetric monitoring of human cardiovascular activity. Two types of photoplethysmography (PPG) sensors for low noise and artefact free signal recording from various sites of the human body that were suitable for integration into smart textile were investigated. The reflectance sensors with single and multiple photodiodes based on "pulse-duration-based signal conversion" signal acquisition principle were designed and evaluated. The technical parameters of the system were measured both on bench and in vivo. Overall, both types of PPG sensors showed acceptable signal quality SNR 86.56±3.00 dB, dynamic range 89.84 dB. However, in-vivo condition tests revealed lower noise and higher accuracy achieved by applying the multiple photodiodes sensor. We concluded that the proposed PPG device prototype is simple and reliable, and therefore, can be utilized in low-cost smart garments.
NASA Technical Reports Server (NTRS)
1980-01-01
The design and development of an advanced Czochralski crystal grower are described. Several exhaust gas analysis system equipment specifications studied are discussed. Process control requirements were defined and design work began on the melt temperature, melt level, and continuous diameter control. Sensor development included assembly and testing of a bench prototype of a diameter scanner system.
Metal Hydrides for High-Temperature Power Generation
Ronnebro, Ewa; Whyatt, Greg A.; Powell, Michael R.; ...
2015-08-10
Metal hydrides can be utilized for hydrogen storage and for thermal energy storage (TES) applications. By using TES with solar technologies, heat can be stored from sun energy to be used later which enables continuous power generation. We are developing a TES technology based on a dual-bed metal hydride system, which has a high-temperature (HT) metal hydride operating reversibly at 600-800°C to generate heat as well as a low-temperature (LT) hydride near room temperature that is used for hydrogen storage during sun hours until there is a need to produce electricity, such as during night time, a cloudy day, ormore » during peak hours. We proceeded from selecting a high-energy density, low-cost HT-hydride based on performance characterization on gram size samples, to scale-up to kilogram quantities and design, fabrication and testing of a 1.5kWh, 200kWh/m 3 bench-scale TES prototype based on a HT-bed of titanium hydride and a hydrogen gas storage instead of a LT-hydride. COMSOL Multiphysics was used to make performance predictions for cylindrical hydride beds with varying diameters and thermal conductivities. Based on experimental and modeling results, a bench-scale prototype was designed and fabricated and we successfully showed feasibility to meet or exceed all performance targets.« less
Experimental and theoretical study of friction torque from radial ball bearings
NASA Astrophysics Data System (ADS)
Geonea, Ionut; Dumitru, Nicolae; Dumitru, Ilie
2017-10-01
In this paper it is presented a numerical simulation and an experimental study of total friction torque from radial ball bearings. For this purpose it is conceived a virtual CAD model of the experimental test bench for bearing friction torque measurement. The virtual model it is used for numerical simulation in Adams software, that allows dynamic study of multi-body systems and in particularly with facility Adams Machinery of dynamic behavior of machine parts. It is manufactured an experimental prototype of the test bench for radial ball bearings friction torque measurement. In order to measure the friction torque of the tested bearings it is used an equal resistance elastic beam element, with strain gauge transducer to measure bending deformations. The actuation electric motor of the bench has the shaft mounted on two bearings and the motor housing is fixed to the free side of the elastic beam, which is bended by a force proportional with the total friction torque. The beam elastic element with strain gauge transducer is calibrated in order to measure the force occurred. Experimental determination of the friction torque is made for several progressive radial loads. It is established the correlation from the friction torque and bearing radial load. The bench allows testing of several types and dimensions of radial bearings, in order to establish the bearing durability and of total friction torque.
Bench-top soldering aid for PC boards
NASA Technical Reports Server (NTRS)
Manton, N. R.; Schroff, R. A.
1978-01-01
Multiple-board rack allows technician to insert components into several boards, flip them all in single motion, and then systematically solder leads on reverse side. Two adjustable crossbars allow boards of any size up to 10 by 24 inches. Operator can rotate racks and adjust angle of boards from standing or sitting position.
A bench-top hyperspectral imaging system to classify beef from Nellore cattle based on tenderness
NASA Astrophysics Data System (ADS)
Nubiato, Keni Eduardo Zanoni; Mazon, Madeline Rezende; Antonelo, Daniel Silva; Calkins, Chris R.; Naganathan, Govindarajan Konda; Subbiah, Jeyamkondan; da Luz e Silva, Saulo
2018-03-01
The aim of this study was to evaluate the accuracy of classification of Nellore beef aged for 0, 7, 14, or 21 days and classification based on tenderness and aging period using a bench-top hyperspectral imaging system. A hyperspectral imaging system (λ = 928-2524 nm) was used to collect hyperspectral images of the Longissimus thoracis et lumborum (aging n = 376 and tenderness n = 345) of Nellore cattle. The image processing steps included selection of region of interest, extraction of spectra, and indentification and evalution of selected wavelengths for classification. Six linear discriminant models were developed to classify samples based on tenderness and aging period. The model using the first derivative of partial absorbance spectra (give wavelength range spectra) was able to classify steaks based on the tenderness with an overall accuracy of 89.8%. The model using the first derivative of full absorbance spectra was able to classify steaks based on aging period with an overall accuracy of 84.8%. The results demonstrate that the HIS may be a viable technology for classifying beef based on tenderness and aging period.
Moon-Mars simulation campaign in volcanic Eifel: Remote science support and sample analysis
NASA Astrophysics Data System (ADS)
Offringa, Marloes; Foing, Bernard H.; Kamps, Oscar
2016-07-01
Moon-Mars analogue missions using a mock-up lander that is part of the ESA/ILEWG ExoGeoLab project were conducted during Eifel field campaigns in 2009, 2015 and 2016 (Foing et al., 2010). In the last EuroMoonMars2016 campaign the lander was used to conduct reconnaissance experiments and in situ geological scientific analysis of samples, with a payload that mainly consisted of a telescope and a UV-VIS reflectance spectrometer. The aim of the campaign was to exhibit possibilities for the ExoGeoLab lander to perform remotely controlled experiments and test its applicability in the field by simulating the interaction with astronauts. The Eifel region in Germany where the experiments with the ExoGeoLab lander were conducted is a Moon-Mars analogue due to its geological setting and volcanic rock composition. The research conducted by analysis equipment on the lander could function in support of Moon-Mars sample return missions, by providing preliminary insight into characteristics of the analyzed samples. The set-up of the prototype lander was that of a telescope with camera and solar power equipment deployed on the top, the UV-VIS reflectance spectrometer together with computers and a sample webcam were situated in the middle compartment and to the side a sample analysis test bench was attached, attainable by astronauts from outside the lander. An alternative light source that illuminated the samples in case of insufficient daylight was placed on top of the lander and functioned on solar power. The telescope, teleoperated from a nearby stationed pressurized transport vehicle that functioned as a base control center, attained an overview of the sampling area and assisted the astronauts in their initial scouting pursuits. Locations of suitable sampling sites based on these obtained images were communicated to the astronauts, before being acquired during a simulated EVA. Sampled rocks and soils were remotely analyzed by the base control center, while the astronauts assisted by placing the samples onto the sample holder and adjusting test bench settings in order to obtain spectra. After analysis the collected samples were documented and stored by the astronauts, before returning to the base. Points of improvement for the EuroMoonMars2016 analog campaign are the remote control of the computers using an established network between the base and the lander. During following missions the computers should preferably be operated over a larger distance without interference. In the bottom compartment of the lander a rover is stored that in future campaigns could replace astronaut functions by collecting and returning samples, as well as performing adjustments to the analysis test bench by using a remotely controlled robotic arm. Acknowledgements: we thank Dominic Doyle for ESTEC optical lab support, Aidan Cowley (EAC) and Matthias Sperl (DLR) for support discussions, and collaborators from EuroMoonMars Eifel 2015-16 campaign team.
Upasani, Vidyadhar V; Chambers, Reid C; Dalal, Ali H; Shah, Suken A; Lehman, Ronald A; Newton, Peter O
2009-08-01
Bench-top and retrospective analysis to assess vertebral rotation based on the appearance of bilateral pedicle screws in patients with adolescent idiopathic scoliosis (AIS). To develop a clinically relevant radiographic grading system for evaluating postoperative thoracic apical vertebral rotation that would correlate with computed tomography (CT) measures of rotation. The 3-column vertebral body control provided by bilateral pedicle screws has enabled scoliosis surgeons to develop advanced techniques of direct vertebral derotation. Our ability to accurately quantify spinal deformity in the axial plane, however, continues to be limited. Trigonometry was used to define the relationship between the position of bilateral pedicle screws and vertebral rotation. This relationship was validated using digital photographs of a bench-top model. The mathematical relationships were then used to calculate vertebral rotation from standing postoperative, posteroanterior radiographs in AIS patients and correlated with postoperative CT measures of rotation. Fourteen digital photographs of the bench-top model were independently analyzed twice by 3 coauthors. The mathematically calculated degree of rotation was found to correlate significantly with the actual degree of rotation (r = 0.99; P < 0.001) and the intra- and interobserver reliability for these measurements were both excellent (kappa = 0.98 and kappa = 0.97, respectively). In the retrospective analysis of 17 AIS patients, the average absolute difference between the radiographic measurement of rotation and the CT measure was only 1.9 degrees +/- 2.0 degrees (r = 0.92; P < 0.001). Based on these correlations a simple radiographic grading system for postoperative apical vertebral rotation was developed. An accurate assessment of vertebral rotation can be performed radiographically, using screw lengths and screw tip-to-rod distances of bilateral segmental pedicle screws and a trigonometric calculation. These data support the use of a simple radiographic grading system to approximate apical vertebral rotation in AIS patients treated with bilateral apical pedicle screws.
A 16-Channel Nonparametric Spike Detection ASIC Based on EC-PC Decomposition.
Wu, Tong; Xu, Jian; Lian, Yong; Khalili, Azam; Rastegarnia, Amir; Guan, Cuntai; Yang, Zhi
2016-02-01
In extracellular neural recording experiments, detecting neural spikes is an important step for reliable information decoding. A successful implementation in integrated circuits can achieve substantial data volume reduction, potentially enabling a wireless operation and closed-loop system. In this paper, we report a 16-channel neural spike detection chip based on a customized spike detection method named as exponential component-polynomial component (EC-PC) algorithm. This algorithm features a reliable prediction of spikes by applying a probability threshold. The chip takes raw data as input and outputs three data streams simultaneously: field potentials, band-pass filtered neural data, and spiking probability maps. The algorithm parameters are on-chip configured automatically based on input data, which avoids manual parameter tuning. The chip has been tested with both in vivo experiments for functional verification and bench-top experiments for quantitative performance assessment. The system has a total power consumption of 1.36 mW and occupies an area of 6.71 mm (2) for 16 channels. When tested on synthesized datasets with spikes and noise segments extracted from in vivo preparations and scaled according to required precisions, the chip outperforms other detectors. A credit card sized prototype board is developed to provide power and data management through a USB port.
Portable oral cancer detection using a miniature confocal imaging probe with a large field of view
NASA Astrophysics Data System (ADS)
Wang, Youmin; Raj, Milan; McGuff, H. Stan; Bhave, Gauri; Yang, Bin; Shen, Ting; Zhang, Xiaojing
2012-06-01
We demonstrate a MEMS micromirror enabled handheld confocal imaging probe for portable oral cancer detection, where a comparatively large field of view (FOV) was generated through the programmable Lissajous scanning pattern of the MEMS micromirror. Miniaturized handheld MEMS confocal imaging probe was developed, and further compared with the desktop confocal prototype under clinical setting. For the handheld confocal imaging system, optical design simulations using CODE VR® shows the lateral and axial resolution to be 0.98 µm and 4.2 µm, where experimental values were determined to be 3 µm and 5.8 µm, respectively, with a FOV of 280 µm×300 µm. Fast Lissajous imaging speed up to 2 fps was realized with improved Labview and Java based real-time imaging software. Properties such as 3D imaging through autofocusing and mosaic imaging for extended lateral view (6 mm × 8 mm) were examined for carcinoma real-time pathology. Neoplastic lesion tissues of giant cell fibroma and peripheral ossifying fibroma, the fibroma inside the paraffin box and ex vivo gross tissues were imaged by the bench-top and handheld imaging modalities, and further compared with commercial microscope imaging results. The MEMS scanner-based handheld confocal imaging probe shows great promise as a potential clinical tool for oral cancer diagnosis and treatment.
Optimization of a miniature Maglev ventricular assist device for pediatric circulatory support.
Zhang, Juntao; Koert, Andrew; Gellman, Barry; Gempp, Thomas M; Dasse, Kurt A; Gilbert, Richard J; Griffith, Bartley P; Wu, Zhongjun J
2007-01-01
A miniature Maglev blood pump based on magnetically levitated bearingless technology is being developed and optimized for pediatric patients. We performed impeller optimization by characterizing the hemodynamic and hemocompatibility performances using a combined computational and experimental approach. Both three-dimensional flow features and hemolytic characteristics were analyzed using computational fluid dynamics (CFD) modeling. Hydraulic pump performances and hemolysis levels of three different impeller designs were quantified and compared numerically. Two pump prototypes were constructed from the two impeller designs and experimentally tested. Comparison of CFD predictions with experimental results showed good agreement. The optimized impeller remarkably increased overall pump hydraulic output by more than 50% over the initial design. The CFD simulation demonstrated a clean and streamlined flow field in the main flow path. The numerical results by hemolysis model indicated no significant high shear stress regions. Through the use of CFD analysis and bench-top testing, the small pediatric pump was optimized to achieve a low level of blood damage and improved hydraulic performance and efficiency. The Maglev pediatric blood pump is innovative due to its small size, very low priming volume, excellent hemodynamic and hematologic performance, and elimination of seal-related and bearing-related failures due to adoption of magnetically levitated bearingless motor technology, making it ideal for pediatric applications.
A 1024-channel 6 mW/mm2 optical stimulator for in-vitro neuroscience experiments.
Cai, Lei; Wang, Baitong; Huang, Xiuxiang; Yang, Zhi
2014-01-01
Recent optical stimulation technologies allow improved selectivity and have been widely used in neuroscience research. This paper presents an optical stimulator based on high power LEDs. It has 1024 channels and can produce flexible stimulation patterns in each frame, refreshed at above 20 Hz. To increase the light intensity, each LED has an optical package that directs the light into a small angle. To ensure the light of each LED can reach the lens, the LEDs have been specially placed and oriented to the lens. With these efforts, the achieved power efficiency (defined as the mount of LED light power passing through the lens divided by the LED total power consumption) is 5 × 10(-5). In our current prototype, an individual LED unit can source 60 mW electrical power, where the induced irradiance on neural tissues is 6 mW/mm(2) integrating from 460 nm to 480 nm. The light spot is tunable in size from 18 μm to 40 μm with an extra 5-10 μm separation for isolating two adjacent spots. Through both bench-top measurement and finite element simulation, we found the cross channel interference is below 10%. A customized software interface has been developed to control and program the stimulator operation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Dr. Yanhua; McCandless, Andrew Bascom
The main objective of this project is to improve the performance and reliability of sensor networks in the smart grid through an active interference cancellation technique that can effectively eliminate broadband electromagnetic interference (EMI) and radio frequency interference (RFI). This noise cancellation provides real-time monitoring the RF environment and automatically optimization of the signal fidelity. To determine the feasibility of the proposed technique and quantify the level of improvement in key system parameters, such as data rate, signal bandwidth, and cost saving, the tasks carried out during Phase I were 1) defining the problem statement, 2) developing a design thatmore » will solve the sensors’ reliably problem, 3) carrying out initial testing with a prototype, and 4) developing an integrated photonic chip version that could be built in a follow-on Phase II effort. The technology demonstration was successfully proven the feasibility of a mission assured photonic sensor system (MAPSS) that will address a major interference problem in smart grid deployments. The significant results demonstrated from bench-top testing show that the technology is capable of maintaining the error free communication link in the presence of various type of interference. The technology’s wideband performance in GHz is also verified and would be suitable for sensors deploying throughout the smart grid system.« less
46 CFR 160.135-13 - Approval inspections and tests for prototype lifeboats.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-11 of this subpart; (ii) Assuring that the quality assurance program of the manufacturer is.... (2) Fiber Reinforced Plastic (FRP) prototype lifeboat lay-up. For the prototype of each design of an... non-portable fuel tank must be tested by a static head above the tank top of 3 m (10 ft) of water...
46 CFR 160.135-13 - Approval inspections and tests for prototype lifeboats.
Code of Federal Regulations, 2014 CFR
2014-10-01
...-11 of this subpart; (ii) Assuring that the quality assurance program of the manufacturer is.... (2) Fiber Reinforced Plastic (FRP) prototype lifeboat lay-up. For the prototype of each design of an... non-portable fuel tank must be tested by a static head above the tank top of 3 m (10 ft) of water...
46 CFR 160.135-13 - Approval inspections and tests for prototype lifeboats.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-11 of this subpart; (ii) Assuring that the quality assurance program of the manufacturer is.... (2) Fiber Reinforced Plastic (FRP) prototype lifeboat lay-up. For the prototype of each design of an... non-portable fuel tank must be tested by a static head above the tank top of 3 m (10 ft) of water...
Test Plan for Cask Identification Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rauch, Eric Benton
2016-09-29
This document serves to outline the testing of a Used Fuel Cask Identification Detector (CID) currently being designed under the DOE-NE MPACT Campaign. A bench-scale prototype detector will be constructed and tested using surrogate neutron sources. The testing will serve to inform the design of the full detector that is to be used as a way of fingerprinting used fuel storage casks based on the neutron signature produced by the used fuel inside the cask.
Local monitoring of post-treatment drinking water using bench-top mass spectrometers could identify target compounds in a mass spectral library. However, a terrorist might seek to incite greater hysteria by injecting or infusing a mixture of unanticipated compounds of unknown tox...
Capabilities Report 2012, West Desert Test Center
2012-03-12
132 FT- IR Spectrometer...electronic system files, paper logs, production batch records, QA/QC data, and PCR data generated during a test. Data analysts also track and QC raw data...Advantage +SL bench-top freeze dryers achieve shelf temperatures as low as -57°C and condenser temperatures to -67°C. The bulk milling facility produces
17. DETAIL INTERIOR VIEW OF CONTROL ROOM ON LEVEL +77 ...
17. DETAIL INTERIOR VIEW OF CONTROL ROOM ON LEVEL +77 OF POWERHOUSE #1; NOTEBOOKS IN FOREGROUND ARE ON TOP OF THE NEW SWITCH GEAR CONTROL CONSOLE; THE ORIGINAL OPERATOR DESK IS IN CENTER; THE ORIGINAL BENCH BOARD CONTROLS ARE IN BACKGROUND. - Bonneville Project, Powerhouse No.1, Spanning Bradford Slough, from Bradford Island, Bonneville, Multnomah County, OR
ERIC Educational Resources Information Center
Brown, Elizabeth R.; Smith, Jessi L.; Thoman, Dustin B.; Allen, Jill M.; Muragishi, Gregg
2015-01-01
Motivating students to pursue science careers is a top priority among many science educators. We add to the growing literature by examining the impact of a utility value intervention to enhance student's perceptions that biomedical science affords important utility work values. Using an expectancy-value perspective, we identified and tested 2…
ERIC Educational Resources Information Center
Twomey, Patrick; O'Sullivan, Colm; O'Riordan, John
2009-01-01
A simple undergraduate experiment designed to study cooling purely by radiation and cooling by a combination of convection and radiation is described. Results indicate that the contribution from radiative cooling in normal laboratory experiments is more significant than students often realize, even in the case of forced cooling. (Contains 1…
ETV Report and Statement for ENDETEC TECTA™ B-16 BY PATHOGEN DETECTION SYSTEMS, INC.
This report provides results for the verification testing of the ENDETEC™ TECTA B-16 by PDS (hereafter referred to as the TECTA™ B-16). The following is a description of the TECTA B-16, based on information provided by the vendor. The TECTA B-16 is a bench top detection and data ...
USDA-ARS?s Scientific Manuscript database
Micronaire is an important fiber quality parameter in the cotton industry. Micronaire is a function of maturity (the degree of the fiber secondary wall development) and fineness (linear density). Bench-top near infrared (NIR) spectroscopy has the ability to measure micronaire, maturity and fineness,...
The design and fabrication of a prototype trash compacting unit. [for long duration space missions
NASA Technical Reports Server (NTRS)
1973-01-01
A prototype trash compactor, that is compatible with the anticipated requirements of future long-term space missions, is described. Preliminary problem definition studies were conducted to identify typical types and quantities of waste materials to be expected from a typical mission. Bench-scale compaction tests were then conducted on typical waste materials to determine force/compaction curves. These data were used to design a boilerplate compactor that was fabricated to prove the feasibility of the basic design concept. A final design was then prepared from which the deliverable unit was fabricated. Design concepts are presented for suggested further development of the compactor, including a version that is capable of handling wet biodegradable wastes.
Localization of a Robotic Crawler for CANDU Fuel Channel Inspection
NASA Astrophysics Data System (ADS)
Manning, Mark
This thesis discusses the design and development of a pipe crawling robot for the purpose of CANDU fuel channel inspection. The pipe crawling robot shall be capable of deploying the existing CIGAR (Channel Inspection and Gauging Apparatus for Reactors) sensor head. The main focus of this thesis is the design of the localization system for this robot and the many tests that were completed to demonstrate its accuracy. The proposed localization system consists of three redundant resolver wheels mounted to the robot's frame and two resolvers that are mounted inside a custom made cable drum. This cable drum shall be referred to in this thesis as the emergency retrieval device. This device serves the dual-purpose of providing absolute position measurements (via the cable that is tethered to the robot) as well as retrieving the robot if it is inoperable. The estimated accuracy of the proposed design is demonstrated with the use of a proof-of-concept prototype and a custom made test bench that uses a vision system to provide a more accurate estimate of the robot's position. The only major difference between the proof-of-concept prototype and the proposed solution is that the more expensive radiation hardened components were not used in the proof-of-concept prototype design. For example, the proposed solution shall use radiation hardened resolver wheels, whereas the proof-of-concept prototype used encoder wheels. These encoder wheels provide the same specified accuracy as the radiation hardened resolvers for the most realistic results possible. The rationale behind the design of the proof-of-concept prototype, the proposed final design, the design of the localization system test bench, and the test plan for developing all of the components of the design related to the robot's localization system are discussed in the thesis. The test plan provides a step by step guide to the configuration and optimization of an Unscented Kalman Filter (UKF). The UKF was selected as the ideal sensor fusion algorithm for use in this application. Benchmarking was completed to compare the accuracy achieved by the UKF algorithm to other data fusion algorithms. When compared to other algorithms, the UKF demonstrated the best accuracy when considering all likely sources of error such as sensor failure and surface unevenness. The test results show that the localization system is able to achieve a worst case positional accuracy of +/- 3.6 mm for the robot crawler over the full 6350 mm distance that the robot travels inside the pressure tube. This is extrapolated from the test results completed over the shorter length test bench with simulated surface unevenness. The key benefits of the pipe crawling robot when compared to the current system include: reduced dosage to workers and the reduced outage time. The advantages are due to the fact that the robot can be automated and multiple inspection robots can be deployed simultaneously. The current inspection system is only able to complete one inspection at a time.
Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.
TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae
2016-01-01
This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.
Barnhill, William C.; Gao, Hong; Kheireddin, Bassem; ...
2015-09-29
We have previously reported an oil-miscible phosphonium-organophosphate ionic liquid (IL) with an effective anti-wear (AW) functionality when added to a base oil by itself or combined with a conventional zinc dialkyldithiophosphate (ZDDP) for a synergistic effect. In this research, we investigated whether this synergy manifests in formulated engine oils. An experimental SAE 0W-16 engine oil was generated containing a combination of IL and ZDDP with equal phosphorus contribution. The prototype engine oil was first evaluated using tribological bench tests: AW performance in boundary lubrication (BL) and friction behavior (Stribeck curves) in elastohydrodynamic, mixed, and BL. In addition, the forthcoming standardmore » Sequence VIE engine dynamometer test was then conducted to demonstrate improved fuel economy. Results were benchmarked against those of another experimental engine oil with almost the same formulation except using ZDDP only without the IL (similar total phosphorus content). The IL-ZDDP formulation consistently outperforms the ZDDP-only formulation in friction reduction and wear protection, and results from the bench and engine tests are well correlated.« less
A Lightweight, Precision-Deployable, Optical Bench for High Energy Astrophysics Missions
NASA Astrophysics Data System (ADS)
Danner, Rolf; Dailey, D.; Lillie, C.
2011-09-01
The small angle of total reflection for X-rays, forcing grazing incidence optics with large collecting areas to long focal lengths, has been a fundamental barrier to the advancement of high-energy astrophysics. Design teams around the world have long recognized that a significant increase in effective area beyond Chandra and XMM-Newton requires either a deployable optical bench or separate X-ray optics and instrument module on formation flying spacecraft. Here, we show that we have in hand the components for a lightweight, precision-deployable optical bench that, through its inherent design features, is the affordable path to the next generation of imaging high-energy astrophysics missions. We present our plans for a full-scale engineering model of a deployable optical bench for Explorer-class missions. We intend to use this test article to raise the technology readiness level (TRL) of the tensegrity truss for a lightweight, precision-deployable optical bench for high-energy astrophysics missions from TRL 3 to TRL 5 through a set of four well-defined technology milestones. The milestones cover the architecture's ability to deploy and control the focal point, characterize the deployed dynamics, determine long-term stability, and verify the stowed load capability. Our plan is based on detailed design and analysis work and the construction of a first prototype by our team. Building on our prior analysis and the high TRL of the architecture components we are ready to move on to the next step. The key elements to do this affordably are two existing, fully characterized, flight-quality, deployable booms. After integrating them into the test article, we will demonstrate that our architecture meets the deployment accuracy, adjustability, and stability requirements. The same test article can be used to further raise the TRL in the future.
Engineering of head-mounted projective displays.
Hua, H; Girardot, A; Gao, C; Rolland, J P
2000-08-01
Head-mounted projective displays (HMPD's) are a novel type of head-mounted display. A HMPD consists of a miniature projection lens mounted upon the user's head and retroreflective sheeting material placed strategically in the environment. First, the imaging concept of a HMPD is reviewed and its potential advantages and disadvantages are discussed. The design and a bench prototype implementation are then presented. Finally, the effects of retroreflective materials on the imaging properties and the optical properties of HMPD's are comprehensively investigated.
Major, Matthew J.; Caldwell, Ryan; Fatone, Stefania
2015-01-01
Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels. PMID:27462383
NASA Astrophysics Data System (ADS)
Moskvin, L. N.; Rakov, V. T.
2015-06-01
The results obtained from testing the secondary-coolant circuit water chemistry of full-scale land-based prototype bench models of vehicular nuclear power installations equipped with water-cooled water-moderated and liquid-metal reactor plants are presented. The influence of copper-containing redox ionexchange resins intended for chemically deoxygenating steam condensate on the working fluid circulation loop's water chemistry is determined. The influence of redox ion-exchange resins on the water chemistry is evaluated by generalizing an array of data obtained in the course of extended monitoring using the methods relating to physicochemical analysis of the quality of condensate-feedwater path media and the methods relating to metallographic analysis of the state of a faulty steam generator's tube system surfaces. The deoxygenating effectiveness of the normal state turbine condensate vacuum deaeration system is experimentally determined. The refusal from applying redox ion-exchange resins in the condensate polishing ion-exchange filters is formulated based on the obtained data on the adverse effect of copper-containing redox ionexchange resins on the condensate-feedwater path water chemistry and based on the data testifying a sufficient effect from using the normal state turbine condensate vacuum deaeration system. Data on long-term operation of the prototype bench model of a vehicular nuclear power installation without subjecting the turbine condensate to chemical deoxygenation are presented.
The Danish Environmental Technology Verification program (DANETV) Water Test Centre operated by DHI, is supported by the Danish Ministry for Science, Technology and Innovation. DANETV, the United States Environmental Protection Agency Environmental Technology Verification Progra...
ERIC Educational Resources Information Center
Smith, York R.; Fuchs, Alan; Meyyappan, M.
2010-01-01
Senior year chemical engineering students designed a process to produce 10 000 tonnes per annum of single wall carbon nanotubes (SWNT) and also conducted bench-top experiments to synthesize SWNTs via fluidized bed chemical vapor deposition techniques. This was an excellent pedagogical experience because it related to the type of real world design…
USDA-ARS?s Scientific Manuscript database
Trans-2-hexenal (T-2-H), a plant-produced aldehyde, was intermittently pumped over a 7 d period into a small, bench top model of stored corn (non-sterile, moisture content about 23%). Naturally occurring bacteria and fungi, including added Aspergillus flavus, grew rapidly on corn not treated with T...
A handheld computer as part of a portable in vivo knee joint load monitoring system
Szivek, JA; Nandakumar, VS; Geffre, CP; Townsend, CP
2009-01-01
In vivo measurement of loads and pressures acting on articular cartilage in the knee joint during various activities and rehabilitative therapies following focal defect repair will provide a means of designing activities that encourage faster and more complete healing of focal defects. It was the goal of this study to develop a totally portable monitoring system that could be used during various activities and allow continuous monitoring of forces acting on the knee. In order to make the monitoring system portable, a handheld computer with custom software, a USB powered miniature wireless receiver and a battery-powered coil were developed to replace a currently used computer, AC powered bench top receiver and power supply. A Dell handheld running Windows Mobile operating system(OS) programmed using Labview was used to collect strain measurements. Measurements collected by the handheld based system connected to the miniature wireless receiver were compared with the measurements collected by a hardwired system and a computer based system during bench top testing and in vivo testing. The newly developed handheld based system had a maximum accuracy of 99% when compared to the computer based system. PMID:19789715
An economical 20 litre bench-top fermenter.
Thiel, Michael A; Coster, Douglas J; Mavrangelos, Christos; Zola, Heddy; Williams, Keryn A
2002-10-01
We describe an economical 20 litre bench-top fermenter suitable for production of recombinant antibody fragments in bacterial expression systems. The bacterial culture contained within a polycarbonate carboy is mixed (400-600 rpm) and aerated (1 vessel vol./min) by a high-shear radial flow impeller mounted on a hollow stainless steel shaft, through which pressurised air is pumped. Air is dispersed as fine bubbles into the culture medium by the turbine impeller, without the need for a porous sparger. A stainless steel baffle stabilised by a gliding counterweight increases mixing. The components can easily be disassembled for cleaning and sterilisation. Temperature (range 20-37 degrees C) and pH (range 7.0-7.5) are controlled manually. Using the apparatus, it proved possible to achieve Escherichia coli cell culture densities equivalent to an optical density at 600 nm (OD(600)) of 30-32, compared with OD(600) 4-6 in shake flasks. A yield of 40 mg/litre/day of a recombinant antibody fragment was obtained with the fermenter, which was 15-fold more than the yield of 2.5mg/litre/day achieved in shake flasks. The fermenter may be particularly suited for research purposes.
A review of electrochemiluminescence (ECL) in and for microfluidic analytical devices.
Kirschbaum, Stefanie E K; Baeumner, Antje J
2015-05-01
The concept and realization of microfluidic total analysis systems (microTAS) have revolutionized the analytical process by integrating the whole breadth of analytical techniques into miniaturized systems. Paramount for efficient and competitive microTAS are integrated detection strategies, which lead to low limits of detection while reducing the sample volume. The concept of electrochemiluminescence (ECL) has been intriguing ever since its introduction based on Ru(bpy)3 (2+) by Tokel and Bard [1] (J Am Chem Soc 1853:2862-2863, 1972), especially because of its immense sensitivity, nonexistent auto-luminescent background signal, and simplicity in experimental design. Therefore, integrating ECL detection into microTAS is a logical consequence to achieve simple, yet highly sensitive, sensors. However, published microanalytical devices employing ECL detection focus in general on traditional ECL chemistry and have yet to take advantage of advances made in standard bench-top ECL strategies. This review will therefore focus on the most recent advancements in microfluidic ECL approaches, but also evaluate the potential impact of bench-top ECL research progress that would further improve performance and lower limits of detection of micro analytical ECL systems, ensuring their desirability as detection principle for microTAS applications.
Evolution of optogenetic microdevices
Kale, Rajas P.; Kouzani, Abbas Z.; Walder, Ken; Berk, Michael; Tye, Susannah J.
2015-01-01
Abstract. Implementation of optogenetic techniques is a recent addition to the neuroscientists’ preclinical research arsenal, helping to expose the intricate connectivity of the brain and allowing for on-demand direct modulation of specific neural pathways. Developing an optogenetic system requires thorough investigation of the optogenetic technique and of previously fabricated devices, which this review accommodates. Many experiments utilize bench-top systems that are bulky, expensive, and necessitate tethering to the animal. However, these bench-top systems can make use of power-demanding technologies, such as concurrent electrical recording. Newer portable microdevices and implantable systems carried by freely moving animals are being fabricated that take advantage of wireless energy harvesting to power a system and allow for natural movements that are vital for behavioral testing and analysis. An investigation of the evolution of tethered, portable, and implantable optogenetic microdevices is presented, and an analysis of benefits and detriments of each system, including optical power output, device dimensions, electrode width, and weight is given. Opsins, light sources, and optical fiber coupling are also discussed to optimize device parameters and maximize efficiency from the light source to the fiber, respectively. These attributes are important considerations when designing and developing improved optogenetic microdevices. PMID:26158015
Okamoto, Nobuhiko; Nakashima, Mitsuko; Tsurusaki, Yoshinori; Miyake, Noriko; Saitsu, Hirotomo; Matsumoto, Naomichi
2013-01-01
Next-generation sequencing (NGS) combined with enrichment of target genes enables highly efficient and low-cost sequencing of multiple genes for genetic diseases. The aim of this study was to validate the accuracy and sensitivity of our method for comprehensive mutation detection in autism spectrum disorder (ASD). We assessed the performance of the bench-top Ion Torrent PGM and Illumina MiSeq platforms as optimized solutions for mutation detection, using microdroplet PCR-based enrichment of 62 ASD associated genes. Ten patients with known mutations were sequenced using NGS to validate the sensitivity of our method. The overall read quality was better with MiSeq, largely because of the increased indel-related error associated with PGM. The sensitivity of SNV detection was similar between the two platforms, suggesting they are both suitable for SNV detection in the human genome. Next, we used these methods to analyze 28 patients with ASD, and identified 22 novel variants in genes associated with ASD, with one mutation detected by MiSeq only. Thus, our results support the combination of target gene enrichment and NGS as a valuable molecular method for investigating rare variants in ASD. PMID:24066114
The sonic window: second generation results
NASA Astrophysics Data System (ADS)
Walker, William F.; Fuller, Michael I.; Brush, Edward V.; Eames, Matthew D. C.; Owen, Kevin; Ranganathan, Karthik; Blalock, Travis N.; Hossack, John A.
2006-03-01
Medical Ultrasound Imaging is widely used clinically because of its relatively low cost, portability, lack of ionizing radiation, and real-time nature. However, even with these advantages ultrasound has failed to permeate the broad array of clinical applications where its use could be of value. A prime example of this untapped potential is the routine use of ultrasound to guide intravenous access. In this particular application existing systems lack the required portability, low cost, and ease-of-use required for widespread acceptance. Our team has been working for a number of years to develop an extremely low-cost, pocket-sized, and intuitive ultrasound imaging system that we refer to as the "Sonic Window." We have previously described the first generation Sonic Window prototype that was a bench-top device using a 1024 element, fully populated array operating at a center frequency of 3.3 MHz. Through a high degree of custom front-end integration combined with multiplexing down to a 2 channel PC based digitizer this system acquired a full set of RF data over a course of 512 transmit events. While initial results were encouraging, this system exhibited limitations resulting from low SNR, relatively coarse array sampling, and relatively slow data acquisition. We have recently begun assembling a second-generation Sonic Window system. This system uses a 3600 element fully sampled array operating at 5.0 MHz with a 300 micron element pitch. This system extends the integration of the first generation system to include front-end protection, pre-amplification, a programmable bandpass filter, four sample and holds, and four A/D converters for all 3600 channels in a set of custom integrated circuits with a combined area smaller than the 1.8 x 1.8 cm footprint of the transducer array. We present initial results from this front-end and present benchmark results from a software beamformer implemented on the Analog Devices BF-561 DSP. We discuss our immediate plans for further integration and testing. This second prototype represents a major reduction in size and forms the foundation of a fully functional, fully integrated, pocket sized prototype.
Combat Ration Network for Technology Implementation (CORANET II) Knurled Seal Heat Bar
2010-08-01
bench top comparison of ultrasonic sealing technology that included the participation of five ultrasonic sealing equipment manufacturers . Project...packaging journals • On-line web search yielded no useful research results • Contact with machine manufactures produced anecdotal evidence of improved...seal characteristics without documentation or research results • One manufacturer suggested rounded seal bars or seal rubbers for improved sealing
A calorimeter for determining radiation and convection in small-scale combustions
R.J. McCarter; A. Broido
1966-01-01
A "bench-top" calorimeter was constructed to determine the radiation-convection partition of energy released in the burning of fuel. Samples of 1 to 2 g, no larger than 4 cm in horizontal dimension, and with flame height less than 15 cm, can be accommodated. The apparatus functions by (1) absorbing radiant energy from the burning fuel in an insulated thin...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ionita, C; Rudin, S; Bednarek, D
Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical propertiesmore » of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.« less
Sensory feedback in prosthetics: a standardized test bench for closed-loop control.
Dosen, Strahinja; Markovic, Marko; Hartmann, Cornelia; Farina, Dario
2015-03-01
Closing the control loop by providing sensory feedback to the user of a prosthesis is an important challenge, with major impact on the future of prosthetics. Developing and comparing closed-loop systems is a difficult task, since there are many different methods and technologies that can be used to implement each component of the system. Here, we present a test bench developed in Matlab Simulink for configuring and testing the closed-loop human control system in standardized settings. The framework comprises a set of connected generic blocks with normalized inputs and outputs, which can be customized by selecting specific implementations from a library of predefined components. The framework is modular and extensible and it can be used to configure, compare and test different closed-loop system prototypes, thereby guiding the development towards an optimal system configuration. The use of the test bench was demonstrated by investigating two important aspects of closed-loop control: performance of different electrotactile feedback interfaces (spatial versus intensity coding) during a pendulum stabilization task and feedforward methods (joystick versus myocontrol) for force control. The first experiment demonstrated that in the case of trained subjects the intensity coding might be superior to spatial coding. In the second experiment, the control of force was rather poor even with a stable and precise control interface (joystick), demonstrating that inherent characteristics of the prosthesis can be an important limiting factor when considering the overall effectiveness of the closed-loop control. The presented test bench is an important instrument for investigating different aspects of human manual control with sensory feedback.
Hemodynamic effects of long-term morphological changes in the human carotid sinus.
Seong, Jaehoon; Jeong, Woowon; Smith, Nataliya; Towner, Rheal A
2015-04-13
Previous investigations of morphology for human carotid artery bifurcation from infancy to young adulthood found substantial growth of the internal carotid artery with advancing age, and the development of the carotid sinus at the root of the internal carotid artery during teenage years. Although the reasons for the appearance of the carotid sinus are not clearly understood yet, it has been hypothesized that the dilation of the carotid sinus serves to support pressure sensing, and slows the blood flow to reduce pulsatility to protect the brain. In order to understand this interesting evolvement at the carotid bifurcation in the aspects of fluid mechanics, we performed in vitro phase-contrast MR flow experiments using compliant silicone replicas of age-dependent carotid artery bifurcations. The silicone models in childhood, adolescence, and adulthood were fabricated using a rapid prototyping technique, and incorporated with a bench-top flow mock circulation loop using a computer-controlled piston pump. The results of the in vitro flow study showed highly complex flow characteristics at the bifurcation in all age-dependent models. However, the highest magnitude of kinetic energy was found at the internal carotid artery in the child model. The high kinetic energy in the internal carotid artery during childhood might be one of the local hemodynamic forces that initiate morphological long-term development of the carotid sinus in the human carotid bifurcation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Resolution performance of a 0.60-NA, 364-nm laser direct writer
NASA Astrophysics Data System (ADS)
Allen, Paul C.; Buck, Peter D.
1990-06-01
ATEQ has developed a high resolution laser scanning printing engine based on the 8 beam architecture of the CORE- 2000. This printing engine has been incorporated into two systems: the CORE-2500 for the production of advanced masks and reticles and a prototype system for direct write on wafers. The laser direct writer incorporates a through-the-lens alignment system and a rotary chuck for theta alignment. Its resolution performance is delivered by a 0. 60 NA laser scan lens and a novel air-jet focus system. The short focal length high resolution lens also reduces beam position errors thereby improving overall pattern accuracy. In order to take advantage of the high NA optics a high performance focus servo was developed capable of dynamic focus with a maximum error of 0. 15 tm. The focus system uses a hot wire anemometer to measure air flow through an orifice abutting the wafer providing a direct measurement to the top surface of resist independent of substrate properties. Lens specifications are presented and compared with the previous design. Bench data of spot size vs. entrance pupil filling show spot size performance down to 0. 35 m FWHM. The lens has a linearity specification of 0. 05 m system measurements of lens linearity indicate system performance substantially below this. The aerial image of the scanned beams is measured using resist as a threshold detector. An effective spot size is
Synthetic Aperture Imaging Polarimeter: Postprint
2010-02-01
mechanical design of the SAlP prototype revol .... es around the concept of a modular array. The modular aspect allows for the array to be built in...imagery of source . The top row images are of the actual fringe pattern incident on the SAlP prototype array. These pictures were taken through the...processed images associated with each of the inputs. The results demonstrated that the SAlP prototype array works in conjunction with the algorithm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staub, J.R.; Richards, B.K.
1993-07-01
Coals from the No. 5 Block coal beds (Westphalian D) of the central Appalachian basin are noted for their blocky, dull character and their low ash and low sulfur content. The beds are multiple benched, with rock partings separating benches. Individual benches have limited lateral extent and, where thick, are dominated by bright, high-ash coal at the base and dull, low-ash coal in the upper parts. The duller coals contain more exinite-group and inertinite-group macerals than the brighter coals. These coal beds are encased in sandstone units dominated by fining-upward sequences. The overall depositional setting is an alluvial-plain environment withmore » northwest-flowing channels spaced approximately 20 km apart. The channels were flanked by clastic swamps about 7 km wide. Low-ash peat accumulated in areas of the flood plain most distant from the channels. These peat-accumulating swamps were about 8 km across. In a few instances low-frequency flood events introduced fine siliciclastic sediment into the peat swamps, depositing a thin layer of sediment on top of the peat. This sediment layer is thicker where the underlying coal is the thickest. These thick coal areas are topographically lower than surrounding coal areas. This relationship between coal thickness, parting thickness, and topography indicates that these peat swamps were planar at the time of deposition. Individual coal benches contain abundant preserved cellular tissue (telocollinite, semifusinite, and fusinite) at most locations, suggesting that robust vegetation was widespread in the swamps and that the morphology was planar. The high concentrations of exinite-group an inertinite-group macerals in the upper parts of benches resulted from selective decomposition and oxidation of the peat in subaerial and aquatic planar-swamp environments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staub, J.R.; Richards, B.K.
1992-01-01
Coals from the No. 5 Block beds (Westphalian D) are noted for their low ash and sulfur content. Beds are multiple benched, with rock partings separating individual benches. Benches have limited continuity and, where thick are dominated by bright, high ash coal at the base and dull, low ash coal in their upper portions. The duller coals contain more exinite and inertinite group macerals than the brighter coals. The depositional setting is an alluvial plain environment with channel systems separated by distances of about 20 km. The channel systems were flanked by clastic swamps for distances of up to 7more » km or more on either side. Areas of flood plain most distant from the channels were sites where peat accumulated and these zones were about 8 km across. High energy, low frequency flood events introduced fine grained sediment into the peat swamps resulting in thin layers of sediment being deposited on top of the peat. These sediment layers are thicker in areas where the underlying coal is the thickest. These thick coal areas are topographically negative. This relationship between coal and parting thickness and topography indicates that these peat swamps were low-lying or planar. Individual coal benches contain abundant amounts of preserved cellular tissue (telocollinite, semifusinite, fusinite) at most locations indicating that woody arborescent like vegetation was widespread in the swamps suggesting a planar morphology. The high concentrations of exinite and inertinite group macerals found in the upper portions of individual benches resulted from decomposition and oxidation of the peat in subaerial to aquatic planar swamp environments.« less
Processes Affecting the Variability of Fluorescence Signals from Benthic Targets in Shallow Waters
1998-09-30
analysis of zooxanthellae isolated from coral samples. We examined fluorescence lifetimes from benthic targets using femtosecond laser based Single...a temporal resolution 5 ps. The laser set-up was employed for laboratory studies of fluorescence lifetimes from model targets such as zooxanthellae ...seagrasses. Over 200 measurements on isolated zooxanthellae were conducted with a bench-top FRR fluorometer and Phase Shift Fluorometer. During the CoBOP-98
Hutengs, Christopher; Ludwig, Bernard; Jung, András; Eisele, Andreas; Vohland, Michael
2018-03-27
Mid-infrared (MIR) spectroscopy has received widespread interest as a method to complement traditional soil analysis. Recently available portable MIR spectrometers additionally offer potential for on-site applications, given sufficient spectral data quality. We therefore tested the performance of the Agilent 4300 Handheld FTIR (DRIFT spectra) in comparison to a Bruker Tensor 27 bench-top instrument in terms of (i) spectral quality and measurement noise quantified by wavelet analysis; (ii) accuracy of partial least squares (PLS) calibrations for soil organic carbon (SOC), total nitrogen (N), pH, clay and sand content with a repeated cross-validation analysis; and (iii) key spectral regions for these soil properties identified with a Monte Carlo spectral variable selection approach. Measurements and multivariate calibrations with the handheld device were as good as or slightly better than Bruker equipped with a DRIFT accessory, but not as accurate as with directional hemispherical reflectance (DHR) data collected with an integrating sphere. Variations in noise did not markedly affect the accuracy of multivariate PLS calibrations. Identified key spectral regions for PLS calibrations provided a good match between Agilent and Bruker DHR data, especially for SOC and N. Our findings suggest that portable FTIR instruments are a viable alternative for MIR measurements in the laboratory and offer great potential for on-site applications.
Feasibility of Crosslinked Acrylic Shape Memory Polymer for a Thrombectomy Device
Muschenborn, Andrea D.; Hearon, Keith; Volk, Brent L.; Conway, Jordan W.; Maitland, Duncan J.
2014-01-01
Purpose To evaluate the feasibility of utilizing a system of SMP acrylates for a thrombectomy device by determining an optimal crosslink density that provides both adequate recovery stress for blood clot removal and sufficient strain capacity to enable catheter delivery. Methods Four thermoset acrylic copolymers containing benzylmethacrylate (BzMA) and bisphenol A ethoxylate diacrylate (Mn~512, BPA) were designed with differing thermomechanical properties. Finite element analysis (FEA) was performed to ensure that the materials were able to undergo the strains imposed by crimping, and fabricated devices were subjected to force-monitored crimping, constrained recovery, and bench-top thrombectomy. Results Devices with 25 and 35 mole% BPA exhibited the highest recovery stress and the highest brittle response as they broke upon constrained recovery. On the contrary, the 15 mole % BPA devices endured all testing and their recovery stress (5 kPa) enabled successful bench-top thrombectomy in 2/3 times, compared to 0/3 for the devices with the lowest BPA content. Conclusion While the 15 mole% BPA devices provided the best trade-off between device integrity and performance, other SMP systems that offer recovery stresses above 5 kPa without increasing brittleness to the point of causing device failure would be more suitable for this application. PMID:25414549
Development and validation of a multilateration test bench for particle accelerator pre-alignment
NASA Astrophysics Data System (ADS)
Kamugasa, Solomon William; Rothacher, Markus; Gayde, Jean-Christophe; Mainaud Durand, Helene
2018-03-01
The development and validation of a portable coordinate measurement solution for fiducialization of compact linear collider (CLIC) components is presented. This new solution addresses two limitations of high-accuracy state-of-the-art coordinate measuring machines, i.e. lack of portability and limited measurement volume. The solution is based on frequency scanning interferometry (FSI) distances and the multilateration coordinate measurement technique. The developments include a reference sphere for localizing the FSI optical fiber tip and a kinematic mount for repositioning the reference sphere with sub-micrometric repeatability. This design enables absolute distance measurements in different directions from the same point, which is essential for multilateration. A multilateration test bench built using these prototypes has been used to fiducialize a CLIC cavity beam position monitor and 420 mm-long main beam quadrupole magnet. The combined fiducialization uncertainty achieved is 3.5 μm (k = 1), which is better than the CLIC 5 μm (k = 1) uncertainty specification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnhill, William C.; Gao, Hong; Kheireddin, Bassem
We have previously reported an oil-miscible phosphonium-organophosphate ionic liquid (IL) with an effective anti-wear (AW) functionality when added to a base oil by itself or combined with a conventional zinc dialkyldithiophosphate (ZDDP) for a synergistic effect. In this research, we investigated whether this synergy manifests in formulated engine oils. An experimental SAE 0W-16 engine oil was generated containing a combination of IL and ZDDP with equal phosphorus contribution. The prototype engine oil was first evaluated using tribological bench tests: AW performance in boundary lubrication (BL) and friction behavior (Stribeck curves) in elastohydrodynamic, mixed, and BL. In addition, the forthcoming standardmore » Sequence VIE engine dynamometer test was then conducted to demonstrate improved fuel economy. Results were benchmarked against those of another experimental engine oil with almost the same formulation except using ZDDP only without the IL (similar total phosphorus content). The IL-ZDDP formulation consistently outperforms the ZDDP-only formulation in friction reduction and wear protection, and results from the bench and engine tests are well correlated.« less
Accuracy improvement in a calibration test bench for accelerometers by a vision system
DOE Office of Scientific and Technical Information (OSTI.GOV)
D’Emilia, Giulio, E-mail: giulio.demilia@univaq.it; Di Gasbarro, David, E-mail: david.digasbarro@graduate.univaq.it; Gaspari, Antonella, E-mail: antonella.gaspari@graduate.univaq.it
2016-06-28
A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behaviormore » if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.« less
DOT National Transportation Integrated Search
2016-12-19
The efforts of this project aim to capture and engage these potentials through a design-research method that incorporates a top down, data-driven approach with bottom-up stakeholder perspectives to develop prototypical scenario-based design solutions...
2017-05-05
About 40 Brevard County high school seniors attended Brevard Top Scholars Day at Kennedy Space Center on May 5. Kennedy's Office of Education coordinated the event that featured a special behind-the-scenes tour of Kennedy, including prototype shops, cryogenic labs and facilities such as the Vehicle Assembly Building and the Launch Control Center firing rooms.
2017-05-05
About 40 Brevard County high school seniors take in the enormity of the Vehicle Assembly Building during Brevard Top Scholars Day on May 5. Kennedy's Office of Education coordinated the event that featured a special behind-the-scenes tour of Kennedy, including prototype shops, cryogenic labs and the Launch Control Center firing rooms.
NASA Astrophysics Data System (ADS)
Omoumi, Farid H.; Wu, Di; Guo, Yuran; Ghani, Muhammad U.; Li, Yuhua; Boyce, Kari E.; Liu, Hong
2018-02-01
The objective of this study is to demonstrate the potential of using the High-energy in-line phase contrast x-ray imaging to detect lesions that are indistinguishable by conventional x-ray mammography but are detectable by supplemental ultrasound screening within dense breasts. For this study, a custom-made prototype x-ray/ultrasound dualmodality phantom that mimics dense breast is created to include embedded carbon fiber disks with multiple diameters and thicknesses. The phase contrast image is acquired using a prototype at 120kVp, 67μA, exposure time of 16.7sec and focal spot size of 18.3μm with average glandular dose (AGD) of 0.3mGy under a geometric magnification of 2.48. The conventional x-ray image is acquired with a bench top system operating at 40kVp, 300μA, exposure time of 50sec and same AGD. The results demonstrate that conventional x-ray imaging is unable to detect any of the carbon fiber disks, while phase contrast imaging and ultrasonography are able to detect most or all of the disks under the applied experimental conditions. These results illustrate phase contrast imaging is capable of detecting targets in a dual-modality phantom which simulates lesions in dense breast tissue, when the simulated lesions are not distinguishable by conventional mammography. Therefore mammographic screening with phase contrast technique could eventually replace both x-ray and ultrasonography for screening detection of small lesions with microcalcification in dense breasts where pathologic lesions are masked due to highly glandular tissue. These results encourage further investigation using high glandular density phantoms to further evaluate the effectiveness of phase contrast imaging as a single modality test, which combines the advantages of both x-ray and ultrasound imaging in cancer screening of patients with dense breasts.
Design and performance of a custom ASIC digitizer for wire chamber readout in 65 nm CMOS technology
NASA Astrophysics Data System (ADS)
Lee, M. J.; Brown, D. N.; Chang, J. K.; Ding, D.; Gnani, D.; Grace, C. R.; Jones, J. A.; Kolomensky, Y. G.; von der Lippe, H.; Mcvittie, P. J.; Stettler, M. W.; Walder, J.-P.
2015-06-01
We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital Converters (TDCs), one 8-bit Analog-to-Digital Converter (ADC), a front-end preamplifier and shaper, plus digital and analog buffers that support a variety of digitization chains. The prototype has a multiplexed digital backend that executes a state machine, distributes control and timing signals, and buffers data for serial output. Laboratory bench tests measure the absolute TDC resolution between 74 ps and 480 ps, growing with the absolute delay, and a relative time resolution of 19 ps. Resolution outliers due to cross-talk between clock signals and supply or reference voltages are seen. After calibration, the ADC displays good linearity and noise performance, with an effective number of bits of 6.9. Under normal operating conditions the circuit consumes 32 mW per channel. Potential design improvements to address the resolution drift and tails are discussed.
A prototype table-top inverse-geometry volumetric CT system.
Schmidt, Taly Gilat; Star-Lack, Josh; Bennett, N Robert; Mazin, Samuel R; Solomon, Edward G; Fahrig, Rebecca; Pelc, Norbert J
2006-06-01
A table-top volumetric CT system has been implemented that is able to image a 5-cm-thick volume in one circular scan with no cone-beam artifacts. The prototype inverse-geometry CT (IGCT) scanner consists of a large-area, scanned x-ray source and a detector array that is smaller in the transverse direction. The IGCT geometry provides sufficient volumetric sampling because the source and detector have the same axial, or slice direction, extent. This paper describes the implementation of the table-top IGCT scanner, which is based on the NexRay Scanning-Beam Digital X-ray system (NexRay, Inc., Los Gatos, CA) and an investigation of the system performance. The alignment and flat-field calibration procedures are described, along with a summary of the reconstruction algorithm. The resolution and noise performance of the prototype IGCT system are studied through experiments and further supported by analytical predictions and simulations. To study the presence of cone-beam artifacts, a "Defrise" phantom was scanned on both the prototype IGCT scanner and a micro CT system with a +/-5 cone angle for a 4.5-cm volume thickness. Images of inner ear specimens are presented and compared to those from clinical CT systems. Results showed that the prototype IGCT system has a 0.25-mm isotropic resolution and that noise comparable to that from a clinical scanner with equivalent spatial resolution is achievable. The measured MTF and noise values agreed reasonably well with theoretical predictions and computer simulations. The IGCT system was able to faithfully reconstruct the laminated pattern of the Defrise phantom while the micro CT system suffered severe cone-beam artifacts for the same object. The inner ear acquisition verified that the IGCT system can image a complex anatomical object, and the resulting images exhibited more high-resolution details than the clinical CT acquisition. Overall, the successful implementation of the prototype system supports the IGCT concept for single-rotation volumetric scanning free from cone-beam artifacts.
Experimental test results of a generalized parameter fuel control
NASA Technical Reports Server (NTRS)
Batterton, P. G.; Gold, H.
1973-01-01
Considerable interest has been generated recently in low cost jet propulsion systems. One of the more complicated components of jet engines is the fuel control. Results of an effort to develop a simpler hydromechanical fuel control are presented. This prototype fuel control was installed on a J85-GE-13 jet engine. Results show that the fuel control provided satisfactory engine performance at sea level static conditions over its normal nonafterburning operating range, including startup. Results of both bench and engine tests are presented; the difficulties encountered are described.
Update on optical design of adaptive optics system at Lick Observatory
NASA Astrophysics Data System (ADS)
Bauman, Brian J.; Gavel, Donald T.; Waltjen, Kenneth E.; Freeze, Gary J.; Hurd, Randall L.; Gates, Elinor L.; Max, Claire E.; Olivier, Scot S.; Pennington, Deanna M.
2002-02-01
In 1999, we presented our plan to upgrade the adaptive optics (AO) system on the Lick Observatory Shane telescope (3m) from a prototype instrument pressed into field service to a facility instrument. This paper updates the progress of that plan and details several important improvements in the alignment and calibration of the AO bench. The paper also includes a discussion of the problems seen in the original design of the tip/tilt (t/t) sensor used in laser guide star mode, and how these problems were corrected with excellent results.
System design and analysis of the trans-critical carbon-dioxide automotive air-conditioning system.
Mu, Jing-Yang; Chen, Jiang-Ping; Chen, Zhi-Jiu
2003-01-01
As an environmentally harmless and feasible alternate refrigerant, CO2 has attracted worldwide attention, especially in the area of automobile air-conditioning (AAC). The thermal property of CO2 and its trans-critical refrigeration cycle is very different from that of the traditional CFC or HCFC system. The detailed process of CO2 system thermal cycle design and optimization is described in this paper. System prototype and performance test bench were developed to analyze the performance of the CO2 AAC system.
Update on Optical Design of Adaptive Optics System at Lick Observatory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauman, B J; Gavel, D T; Waltjen, K E
2001-07-31
In 1999, we presented our plan to upgrade the adaptive optics (AO) system on the Lick Observatory Shane telescope (3m) from a prototype instrument pressed into field service to a facility instrument. This paper updates the progress of that plan and details several important improvements in the alignment and calibration of the AO bench. The paper also includes a discussion of the problems seen in the original design of the tip/tilt (t/t) sensor used in laser guide star mode, and how these problems were corrected with excellent results.
Truss Assembly and Welding by Intelligent Precision Jigging Robots
NASA Technical Reports Server (NTRS)
Komendera, Erik; Dorsey, John T.; Doggett, William R.; Correll, Nikolaus
2014-01-01
This paper describes an Intelligent Precision Jigging Robot (IPJR) prototype that enables the precise alignment and welding of titanium space telescope optical benches. The IPJR, equipped with micron accuracy sensors and actuators, worked in tandem with a lower precision remote controlled manipulator. The combined system assembled and welded a 2 m truss from stock titanium components. The calibration of the IPJR, and the difference between the predicted and the truss dimensions as-built, identified additional sources of error that should be addressed in the next generation of IPJRs in 2D and 3D.
Looking the part (to me): effects of racial prototypicality on race perception vary by prejudice
Sprout, Gregory T.; Freeman, Jonathan B.; Krendl, Anne C.
2017-01-01
Abstract Less racially prototypic faces elicit more category competition during race categorization. Top-down factors (e.g. stereotypes), however, affect categorizations, suggesting racial prototypicality may enhance category competition in certain perceivers. Here, we examined how prejudice affects race category competition and stabilization when perceiving faces varying in racial prototypicality. Prototypically low vs high Black relative to White faces elicited more category competition and slower response latencies during categorization (Experiment 1), suggesting a pronounced racial prototypicality effect on minority race categorization. However, prejudice predicted the extent of category competition between prototypically low vs high Black faces. Suggesting more response conflict toward less prototypic Black vs White faces, anterior cingulate cortex activity increased toward Black vs White faces as they decreased in racial prototypicality, with prejudice positively predicting this difference (Experiment 2). These findings extend the literature on racial prototypicality and categorization by showing that relative prejudice tempers the extent of category competition and response conflict engaged when initially perceiving faces. PMID:28077728
Phase-Conjugate Receiver for Gaussian-State Quantum Illumination
NASA Technical Reports Server (NTRS)
Erkmen, Baris I.; Guha, Saikat
2010-01-01
An active optical sensor probes a region of free space that is engulfed in bright thermal noise to determine the presence (or absence) of a weakly reflecting target. The returned light (which is just thermal noise if no target is present, and thermal noise plus a weak reflection of the probe beam if a target is present) is measured and processed by a receiver and a decision is made on whether a target is present. It has been shown that generating an entangled pair of photons (which is a highly nonclassical state of light), using one photon as the probe beam and storing the other photon for comparison to the returned light, has superior performance to the traditional classical-light (coherent-state) target detection sensors. An entangled-photon transmitter and optimal receiver combination can yield up to a factor of 4 (i.e., 6 dB) gain in the error-probability exponent over a coherent state transmitter and optimal receiver combination, in a highly lossy and noisy scenario (when both sensors have the same number of transmitted photons). However, the receiver that achieves this advantage is not known. One structured receiver can close half of the 6-dB gap (i.e., a 3-dB improvement). It is based on phase-conjugating the returned light, then performing dual-balanced difference detection with the stored half of the entangled-photon pair. Active optical sensors are of tremendous value to NASA s missions. Although this work focuses on target detection, it can be extended to imaging (2D, 3D, hyperspectral, etc.) scenarios as well, where the image quality can be better than that offered by traditional active sensors. Although the current work is theoretical, NASA s future missions could benefit significantly from developing and demonstrating this capability. This is an optical receiver design whose components are, in principle, all implementable. However, the work is currently entirely theoretical. It is necessary to: 1. Demonstrate a bench-top proof of the theoretical principle, 2. Create an operational prototype off-the-bench, and 3. Build a practical sensor that can fly in a mission.
Active vibration control on a quarter-car for cancellation of road noise disturbance
NASA Astrophysics Data System (ADS)
Belgacem, Walid; Berry, Alain; Masson, Patrice
2012-07-01
In this paper, a methodology is presented for the cancellation of road noise, from the analysis of vibration transmission paths for an automotive suspension to the design of an active control system using inertial actuators on a suspension to reduce the vibrations transmitted to the chassis. First, experiments were conducted on a Chevrolet Epica LS automobile on a concrete test track to measure accelerations induced on the suspension by the road. These measurements were combined with experimental Frequency Response Functions (FRFs) measured on a quarter-car test bench to reconstruct an equivalent three dimensional force applied on the wheel hub. Second, FRFs measured on the test bench between the three-dimensional driving force and forces at each suspension/chassis linkage were used to characterize the different transmission paths of vibration energy to the chassis. Third, an experimental model of the suspension was constructed to simulate the configuration of the active control system, using the primary (disturbance) FRFs and secondary (control) FRFs also measured on the test bench. This model was used to optimize the configuration of the control actuators and to evaluate the required forces. Finally, a prototype of an active suspension was implemented and measurements were performed in order to assess the performance of the control approach. A 4.6 dB attenuation on transmitted forces was obtained in the 50-250 Hz range.
2015-06-07
Field-Portable Gas Chromatograph-Mass Spectrometer.” Forensic Toxicol, 2006, 24, 17-22. Smith, P. “Person-Portable Gas Chromatography : Rapid Temperature...bench-top Gas Chromatograph-Mass Spectrometer (GC-MS) system (ISQ). Nine sites were sampled and analyzed for compounds using Environmental Protection...extraction methods for Liquid Chromatography -MS (LC- MS). Additionally, TD is approximately 1000X more sensitive, requires minimal sample preparation
Human Factors and Technical Considerations for a Computerized Operator Support System Prototype
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ulrich, Thomas Anthony; Lew, Roger Thomas; Medema, Heather Dawne
2015-09-01
A prototype computerized operator support system (COSS) has been developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, PI&D system representations, and a recommender module for mitigation actions. At this point, the prototype simulates an interface to a sensor validation module and a fault diagnosis module. These two modules will be fully integrated in the next version of the prototype. The initial version of the prototype is now operational at the Idaho National Laboratory using the U.S. Departmentmore » of Energy’s Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). The HSSL is a full-scope, full-scale glass top simulator capable of simulating existing and future nuclear power plant main control rooms. The COSS is interfaced to the Generic Pressurized Water Reactor (gPWR) simulator with industry-typical control board layouts. The glass top panels display realistic images of the control boards that can be operated by touch gestures. A section of the simulated control board was dedicated to the COSS human-system interface (HSI), which resulted in a seamless integration of the COSS into the normal control room environment. A COSS demonstration scenario has been developed for the prototype involving the Chemical & Volume Control System (CVCS) of the PWR simulator. It involves a primary coolant leak outside of containment that would require tripping the reactor if not mitigated in a very short timeframe. The COSS prototype presents a series of operator screens that provide the needed information and soft controls to successfully mitigate the event.« less
DOT National Transportation Integrated Search
2003-01-01
The primary objective of this project was to test a full-scale prototype of a bridge deck design containing glass fiber reinforced polymer (GFRP) bars as the top mat of reinforcement. The test deck mimics the design of the deck of one span of the new...
NASA Technical Reports Server (NTRS)
Treiman, Allan H.
1997-01-01
A sequence of layers, bright and dark, is exposed on the walls of canyons, impact craters and mesas throughout the Ares Vallis region, Chryse Planitia, and Xanthe Terra, Mars. Four layers can be seen: two pairs of alternating dark and bright albedo. The upper dark layer forms the top surface of many walls and mesas. The upper dark-bright pair was stripped as a unit from many streamlined mesas and from the walls of Ares Valles, leaving a bench at the top of the lower dark layer, approximately 250 m below the highland surface on streamlined islands and on the walls of Ares Vallis itself. Along Ares Vallis, the scarp between the highlands surface and this bench is commonly angular in plan view (not smoothly curving), suggesting that erosion of the upper dark-bright pair of layers controlled by planes of weakness, like fractures or joints. These near-surface layers in the Ares Vallis area have similar thicknesses, colors, and resistances to erosion to layers exposed near the tops of walls in Valles Marineris (Treiman et al.) and may represent the same pedogenic hardpan units. From this correlation, and from analogies with hardpans on Earth, the light-color layers may be cemented by calcite or gypsum. The dark layers are likely cemented by an iron-bearing mineral. Mars Pathfinder instruments should permit recognition and useful analyses of hardpan fragments, provided that clean uncoated surfaces are accessible. Even in hardpan-cemented materials, it should be possible to determine the broad types of lithologies in the Martian highlands. However, detailed geochemical modeling of highland rocks and soils may be compromised by the presence of hardpan cement minerals.
Trajectory correction propulsion for TOPS
NASA Technical Reports Server (NTRS)
Long, H. R.; Bjorklund, R. A.
1972-01-01
A blowdown-pressurized hydrazine propulsion system was selected to provide trajectory correction impulse for outer planet flyby spacecraft as the result of cost/mass/reliability tradeoff analyses. Present hydrazine component and system technology and component designs were evaluated for application to the Thermoelectric Outer Planet Spacecraft (TOPS); while general hydrazine technology was adequate, component design changes were deemed necessary for TOPS-type missions. A prototype hydrazine propulsion system was fabricated and fired nine times for a total of 1600 s to demonstrate the operation and performance of the TOPS propulsion configuration. A flight-weight trajectory correction propulsion subsystem (TCPS) was designed for the TOPS based on actual and estimated advanced components.
Loturco, Irineu; Kobal, Ronaldo; Moraes, José E; Kitamura, Katia; Cal Abad, César C; Pereira, Lucas A; Nakamura, Fábio Y
2017-04-01
Loturco, I, Kobal, R, Moraes, JE, Kitamura, K, Cal Abad, CC, Pereira, LA, and Nakamura, FY. Predicting the maximum dynamic strength in bench press: the high precision of the bar velocity approach. J Strength Cond Res 31(4): 1127-1131, 2017-The aim of this study was to determine the force-velocity relationship and test the possibility of determining the 1 repetition maximum (1RM) in "free weight" and Smith machine bench presses. Thirty-six male top-level athletes from 3 different sports were submitted to a standardized 1RM bench press assessment (free weight or Smith machine, in randomized order), following standard procedures encompassing lifts performed at 40-100% of 1RM. The mean propulsive velocity (MPV) was measured in all attempts. A linear regression was performed to establish the relationships between bar velocities and 1RM percentages. The actual and predicted 1RM for each exercise were compared using a paired t-test. Although the Smith machine 1RM was higher (10% difference) than the free weight 1RM, in both cases the actual and predicted values did not differ. In addition, the linear relationship between MPV and percentage of 1RM (coefficient of determination ≥95%) allow determination of training intensity based on the bar velocity. The linear relationships between the MPVs and the relative percentages of 1RM throughout the entire range of loads enable coaches to use the MPV to accurately monitor their athletes on a daily basis and accurately determine their actual 1RM without the need to perform standard maximum dynamic strength assessments.
Evaluation of Rotating Biological Contactor Technology for Civil Works Recreational Areas.
1982-04-01
Engineers, Midland District Centre, United Kingdom , November 1972). This study investigated the diurnal variations in flow and their effect on RBC... Industrial Waste Conference (1975), p 675. With a six-stage bench-top RBC unit and a synthetic apple waste contain- ing approximately 900 mg/L of BOD, the...AO-AI16 759 CONSTRUCTION ENGINEERING RESEARCH LAB (ARMY) CHAMPAIGN IL F/G 13/2 EVALUATION OF ROTATING BIOLOGICAL CONTACTOR TECHNOLOGY FOR CIVI-ETC(U
2011-03-01
2010). Ferreri’s research on characterizing burnt carbon composite material entailed a similar approach to evaluate a bench top experiment with the...However, it made it difficult to collect the needed data for comparison. A chop saw, similar to a concrete saw used in construction, was the tool...representative of that to which crash recovery members might be exposed. It is acknowledged that the diesel exhaust from the excavator and concrete saw may
Monolithic integrated optic fiber Bragg grating sensor interrogator
NASA Astrophysics Data System (ADS)
Mendoza, Edgar A.; Esterkin, Yan; Kempen, Cornelia; Sun, Songjian
2010-04-01
Fiber Bragg gratings (FBGs) are a mature sensing technology that has gained rapid acceptance in civil, aerospace, chemical and petrochemical, medicine, aviation and automotive industries. Fiber Bragg grating sensors can be use for a variety of measurements including strain, stress, vibration, acoustics, acceleration, pressure, temperature, moisture, and corrosion distributed at multiple locations within the structure using a single fiber element. The most prominent advantages of FBGs are: small size and light weight, multiple FBG transducers on a single fiber, and immunity to radio frequency interference. A major disadvantage of FBG technology is that conventional state-of-the-art fiber Bragg grating interrogation systems are typically bulky, heavy, and costly bench top instruments that are assembled from off-the-shelf fiber optic and optical components integrated with a signal electronics board into an instrument console. Based on the need for a compact FBG interrogation system, this paper describes recent progress towards the development of a miniature fiber Bragg grating sensor interrogator (FBG-TransceiverTM) system based on multi-channel monolithic integrated optic sensor microchip technology. The integrated optic microchip technology enables the monolithic integration of all of the functionalities, both passive and active, of conventional bench top FBG sensor interrogators systems, packaged in a miniaturized, low power operation, 2-cm x 5-cm small form factor (SFF) package suitable for the long-term structural health monitoring in applications where size, weight, and power are critical for operation.
Khoo, T-L; Xiros, N; Guan, F; Orellana, D; Holst, J; Joshua, D E; Rasko, J E J
2013-08-01
The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (<1%), and overall interinstrument agreement was acceptable for both human and mouse samples. Comparison between the CELL-DYN Emerald and Sapphire analyzers for human samples or Sysmex XT2000iV analyzer for mouse samples showed excellent correlation for all parameters. The CELL-DYN Emerald was generally comparable to the larger reference analyzer for both human and mouse samples. It would be suitable for use in satellite research laboratories or as a backup system in larger laboratories. © 2012 John Wiley & Sons Ltd.
Santibáñez, M; Saavedra, R; Vásquez, M; Malano, F; Pérez, P; Valente, M; Figueroa, R G
2017-11-01
The present work is devoted to optimizing the sensitivity-doses relationship of a bench-top EDXRF system, with the aim of achieving a detection limit of 0.010mg/ml of gold nanoparticles in tumor tissue (clinical values expected), for doses below 10mGy (value fixed for in vivo application). Tumor phantoms of 0.3cm 3 made of a suspension of gold nanoparticles (15nm AurovistTM, Nanoprobes Inc.) were studied at depths of 0-4mm in a tissue equivalent cylindrical phantom. The optimization process was implemented configuring several tube voltages and aluminum filters, to obtain non-symmetrical narrow spectra with fixed FWHM of 5keV and centered among the 11.2-20.3keV. The used statistical figure of merit was the obtained sensitivity (with each spectrum at each depth) weighted by the delivered surface doses. The detection limit of the system was determined measuring several gold nanoparticles concentrations ranging from 0.0010 to 5.0mg/ml and a blank sample into tumor phantoms, considering a statistical fluctuation within 95% of confidence. The results show the possibility of obtaining a detection limit for gold nanoparticles concentrations around 0.010mg/ml for surface tumor phantoms requiring doses around 2mGy. Copyright © 2017 Elsevier Ltd. All rights reserved.
Fundamental Studies of Ignition Process in Large Natural Gas Engines Using Laser Spark Ignition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azer Yalin; Bryan Willson
Past research has shown that laser ignition provides a potential means to reduce emissions and improve engine efficiency of gas-fired engines to meet longer-term DOE ARES (Advanced Reciprocating Engine Systems) targets. Despite the potential advantages of laser ignition, the technology is not seeing practical or commercial use. A major impediment in this regard has been the 'open-path' beam delivery used in much of the past research. This mode of delivery is not considered industrially practical owing to safety factors, as well as susceptibility to vibrations, thermal effects etc. The overall goal of our project has been to develop technologies andmore » approaches for practical laser ignition systems. To this end, we are pursuing fiber optically coupled laser ignition system and multiplexing methods for multiple cylinder engine operation. This report summarizes our progress in this regard. A partial summary of our progress includes: development of a figure of merit to guide fiber selection, identification of hollow-core fibers as a potential means of fiber delivery, demonstration of bench-top sparking through hollow-core fibers, single-cylinder engine operation with fiber delivered laser ignition, demonstration of bench-top multiplexing, dual-cylinder engine operation via multiplexed fiber delivered laser ignition, and sparking with fiber lasers. To the best of our knowledge, each of these accomplishments was a first.« less
2011-08-01
5 Figure 4 Architetural diagram of running Blender on Amazon EC2 through Nimbis...classification of streaming data. Example input images (top left). All digit prototypes (cluster centers) found, with size proportional to frequency (top...Figure 4 Architetural diagram of running Blender on Amazon EC2 through Nimbis 1 http
Kouzani, Abbas Z; Kale, Rajas P; Zarate-Garza, Pablo Patricio; Berk, Michael; Walder, Ken; Tye, Susannah J
2017-09-01
Deep brain stimulation (DBS) devices deliver electrical pulses to neural tissue through an electrode. To study the mechanisms and therapeutic benefits of deep brain stimulation, murine preclinical research is necessary. However, conducting naturalistic long-term, uninterrupted animal behavioral experiments can be difficult with bench-top systems. The reduction of size, weight, power consumption, and cost of DBS devices can assist the progress of this research in animal studies. A low power, low weight, miniature DBS device is presented in this paper. This device consists of electronic hardware and software components including a low-power microcontroller, an adjustable current source, an n-channel metal-oxide-semiconductor field-effect transistor, a coin-cell battery, electrode wires and a software program to operate the device. Evaluation of the performance of the device in terms of battery lifetime and device functionality through bench and in vivo tests was conducted. The bench test revealed that this device can deliver continuous stimulation current pulses of strength [Formula: see text], width [Formula: see text], and frequency 130 Hz for over 22 days. The in vivo tests demonstrated that chronic stimulation of the nucleus accumbens (NAc) with this device significantly increased psychomotor activity, together with a dramatic reduction in anxiety-like behavior in the elevated zero-maze test.
Looking the part (to me): effects of racial prototypicality on race perception vary by prejudice.
Cassidy, Brittany S; Sprout, Gregory T; Freeman, Jonathan B; Krendl, Anne C
2017-04-01
Less racially prototypic faces elicit more category competition during race categorization. Top-down factors (e.g. stereotypes), however, affect categorizations, suggesting racial prototypicality may enhance category competition in certain perceivers. Here, we examined how prejudice affects race category competition and stabilization when perceiving faces varying in racial prototypicality. Prototypically low vs high Black relative to White faces elicited more category competition and slower response latencies during categorization (Experiment 1), suggesting a pronounced racial prototypicality effect on minority race categorization. However, prejudice predicted the extent of category competition between prototypically low vs high Black faces. Suggesting more response conflict toward less prototypic Black vs White faces, anterior cingulate cortex activity increased toward Black vs White faces as they decreased in racial prototypicality, with prejudice positively predicting this difference (Experiment 2). These findings extend the literature on racial prototypicality and categorization by showing that relative prejudice tempers the extent of category competition and response conflict engaged when initially perceiving faces. © The Author (2017). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Next Generation Programmable Bio-Nano-Chip System for On-Site Detection in Oral Fluids.
Christodoulides, Nicolaos; De La Garza, Richard; Simmons, Glennon W; McRae, Michael P; Wong, Jorge; Newton, Thomas F; Kosten, Thomas R; Haque, Ahmed; McDevitt, John T
2015-11-23
Current on-site drug of abuse detection methods involve invasive sampling of blood and urine specimens, or collection of oral fluid, followed by qualitative screening tests using immunochromatographic cartridges. Test confirmation and quantitative assessment of a presumptive positive are then provided by remote laboratories, an inefficient and costly process decoupled from the initial sampling. Recently, a new noninvasive oral fluid sampling approach that is integrated with the chip-based Programmable Bio-Nano-Chip (p-BNC) platform has been developed for the rapid (~ 10 minutes), sensitive detection (~ ng/ml) and quantitation of 12 drugs of abuse. Furthermore, the system can provide the time-course of select drug and metabolite profiles in oral fluids. For cocaine, we observed three slope components were correlated with cocaine-induced impairment using this chip-based p-BNC detection modality. Thus, this p-BNC has significant potential for roadside drug testing by law enforcement officers. Initial work reported on chip-based drug detection was completed using 'macro' or "chip in the lab" prototypes, that included metal encased "flow cells", external peristaltic pumps and a bench-top analyzer system instrumentation. We now describe the next generation miniaturized analyzer instrumentation along with customized disposables and sampling devices. These tools will offer real-time oral fluid drug monitoring capabilities, to be used for roadside drug testing as well as testing in clinical settings as a non-invasive, quantitative, accurate and sensitive tool to verify patient adherence to treatment.
Towards a disposable in vivo miniature implantable fluorescence detector
NASA Astrophysics Data System (ADS)
Bellis, Stephen; Jackson, J. Carlton; Mathewson, Alan
2006-02-01
In the field of fluorescent microscopy, neuronal activity, diabetes and drug treatment are a few of the wide ranging biomedical applications that can be monitored with the use of dye markers. Historically, in-vivo fluorescent detectors consist of implantable probes coupled by optical fibre to sophisticated bench-top instrumentation. These systems typically use laser light to excite the fluorescent marker dies and using sensors, such as the photo-multiplier tube (PMT) or charge coupled devices (CCD), detect the fluorescent light that is filtered from the total excitation. Such systems are large and expensive. In this paper we highlight the first steps toward a fully implantable in-vivo fluorescence detection system. The aim is to make the detector system small, low cost and disposable. The current prototype is a hybrid platform consisting of a vertical cavity surface emitting laser (VCSEL) to provide the excitation and a filtered solid state Geiger mode avalanche photo-diode (APD) to detect the emitted fluorescence. Fluorescence detection requires measurement of extremely low levels of light so the proposed APD detectors combine the ability to count individual photons with the added advantage of being small in size. At present the exciter and sensor are mounted on a hybrid PCB inside a 3mm diameter glass tube.This is wired to external electronics, which provide quenching, photon counting and a PC interface. In this configuration, the set-up can be used for in-vitro experimentation and in-vivo analysis conducted on animals such as mice.
A Point-of-Need infrared mediated PCR platform with compatible lateral flow strip for HPV detection.
Liu, Wenjia; Zhang, Mingfang; Liu, Xiaoyan; Sharma, Alok; Ding, Xianting
2017-10-15
With the increasing need of monitoring the epidemiology of serious infectious diseases, food hygiene, food additives and pesticide residues, it is urgent to develop portable, easy-to-use, inexpensive and rapid molecular diagnostic tools. Herein, we demonstrate a prototype of IR mediated Conducting Oil and CarbOn Nanotube circUlaTing PCR (IR-COCONUT PCR) platform for nucleic acid amplification. The presented platform offers a new solution for miniaturized PCR instruments with non-contact heaters by using conducting oil and carbon nanotube as a medium in IR mediated PCR. This novel platform offers accurate and flexible control of temperature through the integration of PID (proportional-integral-derivative) algorithms to manipulate the duty cycle of the voltage signals of IR LED and a peristaltic pump. The ramping rate of the introduced platform in current study is 1.5°C/s for heating speed and -2.0°C/s for cooling speed. This platform fulfills 30 thermal cycles within 50min which is a match to the conventional bench-top PCR thermo cyclers. For demonstration purpose, human papillomavirus (HPV) patient cervical swab specimens were examined. Downstream lateral flow strip (LFS) was also developed to quantity the PCR products from the IR-COCONUT PCR device within 25min. This PCR platform together with the compatible LFS shows great potential for in-field and Point-of-Need (PoN) testing of genetic or contagious diseases. Copyright © 2017 Elsevier B.V. All rights reserved.
Commutated automatic gain control system
NASA Technical Reports Server (NTRS)
Yost, S. R.
1982-01-01
A commutated automatic gain control (AGC) system was designed and built for a prototype Loran C receiver. The receiver uses a microcomputer to control a memory aided phase-locked loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The circuit designed for the AGC is described, and bench and flight test results are presented. The AGC circuit described actually samples starting at a point 40 microseconds after a zero crossing determined by the software lock pulse ultimately generated by a 30 microsecond delay and add network in the receiver front end envelope detector.
NASA Technical Reports Server (NTRS)
1995-01-01
This final report describes the work performed from June 1993 to January 1995. The purpose of this contract was to provide optomechanical engineering and fabrication support to the Solar X-ray Imager (SXI) program in the areas of mirror, optical bench and camera assemblies of the telescope. The Center for Applied Optics (CAO) worked closely with the Optics and S&E technical staff of MSFC to develop and investigate the most viable and economical options for the design and fabrication of a number of parts for the various telescope assemblies. All the tasks under this delivery order have been successfully completed within budget and schedule.
NASA Technical Reports Server (NTRS)
1980-01-01
A rolltrusion process was developed for forming of a hybrid, single-ply woven graphite and glass fiber cloth, impregnated with a polysulfone resin and coated with TI02 pigmented P-1700 resin into strips for the on-orbit fabrication of triangular truss segments. Ultrasonic welding in vacuum showed no identifiable effects on weld strength or resin flow characteristics. An existing bench model cap roll forming machine was modified and used to roll form caps for the prototype test truss and for column test specimens in order to test local buckling and torsional instability characteristics.
Engagement of Metal Debris into Gear Mesh
NASA Technical Reports Server (NTRS)
handschuh, Robert F.; Krantz, Timothy L.
2010-01-01
A series of bench-top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined.
Numerical modeling of immiscible two-phase flow in micro-models using a commercial CFD code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crandall, Dustin; Ahmadia, Goodarz; Smith, Duane H.
2009-01-01
Off-the-shelf CFD software is being used to analyze everything from flow over airplanes to lab-on-a-chip designs. So, how accurately can two-phase immiscible flow be modeled flowing through some small-scale models of porous media? We evaluate the capability of the CFD code FLUENT{trademark} to model immiscible flow in micro-scale, bench-top stereolithography models. By comparing the flow results to experimental models we show that accurate 3D modeling is possible.
2008-03-01
will be accomplished by the day prior to the sample transfer operation. i. The radiation hood lab bench tops where radioactive material will be...source container to a sample container in a single syringe transfer. (All other non- radioactive solutions will have been previously added to this... radioactive spill. 4. Procedure Checklist: a. Setup □ Tape down plastic liner and locate absorbent □ Lay out sample container holder, sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cosimbescu, Lelia; Robinson, Joshua W.; Bays, John Timothy
The manuscript captures the chronological succession of the molecular design progression through multiple architectures and topologies of the polymeric viscosity index improvers and their rheology bench test performance. Tribology testing was also performed on selected analogs and their friction and wear was evaluated. Finally, a top performing polymer was selected for engine testing, scaled-up, and its rheological performance in a complete formulation was assessed. The engine performance of the viscosity index improver was examined against an industry-established baseline.
Advanced, Energy-Efficient Hybrid Membrane System for Industrial Water Reuse
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toy, Lora; Choi, Young Chul; Hendren, Zachary
In the U.S. manufacturing sector, current industrial water use practices are energy-intensive and utilize and discharge high volumes of waters, rendering them not sustainable especially in light of the growing scarcity of suitable water supplies. To help address this problem, the goal of this project was to develop an advanced, cost-effective, hybrid membrane-based water treatment system that can improve the energy efficiency of industrial wastewater treatment while allowing at least 50% water reuse efficiency. This hybrid process would combine emerging Forward Osmosis (FO) and Membrane Distillation (MD) technology components into an integrated FO-MD system that can beneficially utilize low-grade wastemore » heat (i.e., T < 450 °F) in industrial facilities to produce distilled-quality product water for reuse. In this project, laboratory-, bench-, and pilot-scale experiments on the hybrid FO-MD system were conducted for industrial wastewater treatment. It was demonstrated at laboratory, bench, and pilot scales that FO-MD membrane technology can concentrate brine to very high total dissolved solids (TDS) levels (>200,000 ppm) that are at least 2.5 times higher than the TDS level to which RO can achieve. In laboratory testing, currently available FO and MD membranes were tested to select for high-performing membranes with high salt rejection and high water flux. Multiple FO membrane/draw-salt solution combinations that gave high water flux with higher than 98% salt rejection were also identified. Reverse draw-salt fluxes were observed to be much lower for divalent salts than for monovalent salts. MD membranes were identified that had 99.9+% salt rejection and water flux as high as 50-90 L/(m 2·h) for flat-sheet membranes and >20 L/(m 2·h) for hollow fibers. In bench-scale testing, a single unit of commercially available FO and MD membrane modules were evaluated for continuous, integrated operation. Using the laboratory- and bench-scale test data, numerical modeling was performed on the FO and MD processes to estimate engineering parameters for a larger-scale pilot unit. Based on the experimental studies and modeling results, a pilot-scale, integrated FO-MD prototype unit was designed and built for trailer-mounted operation. This prototype system was fed real industrial wastewater, which could not be further treated by conventional technologies, from an oil production facility and was successfully operated for over 15 weeks without major stoppage. About 90% water recovery was possible, while concentrating the TDS from 12,000 ppm up to 190,500 ppm. The FO-MD prototype rejected most wastewater contaminants while producing water with <300 ppm TDS, even when the feed TDS was higher than 150,000 ppm. No chemical cleaning was necessary during the pilot testing period. Flushing the system with dechlorinated tap water was sufficient to reset the membranes for the next set of test conditions. Pilot performance and membrane autopsy showed that, even though the feed was concentrated more than 10 times, membrane fouling was unnoticeable and no defects were detected on the FO and MD membrane surfaces. This project demonstrated the technical feasibility of the hybrid FO-MD process by taking water already treated to the limit with the highest level of current technologies and further concentrating it 10-fold by using mostly low-cost materials. Because no membranes suitable for full-scale plant applications are available at present, economical feasibility of the hybrid technology is still uncertain, but it is expected that broader industry participation can further reduce FO-MD process costs.« less
Investigation of an Ultrafast Harmonic Resonant RF Kicker
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Yulu
An Energy Recovery Linac (ERL) based multi-turn electron Circulator Cooler Ring (CCR) is envisaged in the proposed Jefferson Lab Electron Ion Collider (JLEIC) to cool the ion bunches with high energy (55 MeV), high current (1.5 A), high repetition frequency (476.3 MHz), high quality magnetized electron bunches. A critical component in this scheme is a pair of ultrafast kickers for the exchange of electron bunches between the ERL and the CCR. The ultrafast kicker should operate with the rise and fall time in less than 2.1 ns, at the repetition rate of ~10s MHz, and should be able to runmore » continuously during the whole period of cooling. These -and-fall time being combined together, are well beyond the state-of-art of traditional pulsed power supplies and magnet kickers. To solve this technical challenge, an alternative method is to generate this high repetition rate, fast rise-and-fall time short pulse continuous waveform by summing several finite number of (co)sine waves at harmonic frequencies of the kicking repetition frequency, and these harmonic modes can be generated by the Quarter Wave Resonater (QWR) based multifrequency cavities. Assuming the recirculator factor is 10, 10 harmonic modes (from 47.63 MHz to 476.3 MHz) with proper amplitudes and phases, plus a DC offset are combined together, a continuous short pulse waveform with the rise-and-fall time in less than 2.1 ns, repetition rate of 47.63 MHz waveform can be generated. With the compact and matured technology of QWR cavities, the total cost of both hardware development and operation can be reduced to a modest level. Focuse on the technical scheme, three main topics will be discussed in this thesis: the synthetization of the kicking pulse, the design and optimization of the deflecting QWR multi-integer harmonic frequency resonator and the fabrication and bench measurements of a half scale copper prototype. In the kicking pulse synthetization part, we begin with the Fourier Series expansion of an ideal square pulse, and get a Flat-Top waveform which will give a uniform kick over the bunch length of the kicked electron bunches, thus the transverse emittance of these kicked electron bunches can be maintained. By using two identical kickers with the betatron phase advance of 180 degree or its odd multiples, the residual kick voltage wave slopes at the unkicked bunch position will be totally cancelled out. Flat-Top waveform combined with two kicker scheme, the transverse emittance of the cooling electron bunches will be conserved during the whole injection, recirculation, and ejection processes. In the cavity design part, firstly, the cavity geometry is optimized to get high transverse shunt impedance thus less than 100 W of RF losses on the cavity wall can be achieved for all these 10 harmonic modes. To support all these 10 harmonic modes, group of four QWRs are adopted with the mode distribution of 5:3:1:1. In the multi-frequency cavities such as the five-mode-cavity and the three-mode-cavity, tunings are required to achieve the design frequencies for each mode. Slight segments of taper design on the inner conductor help to get the frequencies to be exactly on the odd harmonic modes. Stub tuners equal to the number of resonant modes are inserted to the outer conductor wall to compensate the frequency shifts due manufacturing errors and other perturbations during the operation such as the change of the cavity temperature. Single loop couple is designed for all harmonic modes in each cavity. By adjusting its loop size, position and rotation, it is possible to get the fundamental mode critical coupled and other higher harmonic modes slightly over coupled. A broadband circulator will be considered for absorbing the reflected power. Finally in this part, multipole field components due to the asymmetric cylindrical structure around the beam axis of the cavity as well as the beam-induced higher order mode (HOM) issues will be analyzed and discussed in this thesis. A half-scale copper prototype cavity (resonant frequencies from 95.26 MHz to 857.34 MHz) was fabricated to validate the electromagnetic characteristics. With this half scale prototype, the tuning processes of multiple harmonic frequencies, unloaded quality factor measurements of each mode, and bead-pull measurements are performed. The bench measurement results matched well with the simulation results, which have validated our cavity design and construction methods. Finally, a simple mode combining experiment with five separate signal generators was performed on this prototype cavity and the desired fast rise/fall time (1.2 ns), high repetition rate (95.26 MHz) waveform was captured, which finally proved our design of this ultrafast harmonic kicker.« less
''Towards a High-Performance and Robust Implementation of MPI-IO on Top of GPFS''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prost, J.P.; Tremann, R.; Blackwore, R.
2000-01-11
MPI-IO/GPFS is a prototype implementation of the I/O chapter of the Message Passing Interface (MPI) 2 standard. It uses the IBM General Parallel File System (GPFS), with prototyped extensions, as the underlying file system. this paper describes the features of this prototype which support its high performance and robustness. The use of hints at the file system level and at the MPI-IO level allows tailoring the use of the file system to the application needs. Error handling in collective operations provides robust error reporting and deadlock prevention in case of returning errors.
Characterizing the Influence of Abstraction in Full-Scale Wind Turbine Nacelle Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schkoda, Ryan; Bibo, Amin; Guo, Yi
2016-08-21
In recent years, there has been a growing interest in full-scale wind turbine nacelle testing to complement individual component testing. As a result, several wind turbine nacelle test benches have been built to perform such testing with the intent of loading the integrated components as they are in the field. However, when mounted on a test bench the nacelle is not on the top of a tower and does not have blades attached to it - this is a form of abstraction. This paper aims to quantify the influence of such an abstraction on the dynamic response of the nacellemore » through a series of simulation case studies. The responses of several nacelle components are studied including the main bearing, main shaft, gearbox supports, generator, and yaw bearing interface. Results are presented to highlight the differences in the dynamic response of the nacelle caused by the abstraction. Additionally, the authors provide recommendations for mitigating the effects of the abstraction.« less
Characterizing the Influence of Abstraction in Full-Scale Wind Turbine Nacelle Testing: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schkoda, Ryan; Bibo, Amin; Guo, Yi
2016-08-01
In recent years, there has been a growing interest in full-scale wind turbine nacelle testing to complement individual component testing. As a result, several wind turbine nacelle test benches have been built to perform such testing with the intent of loading the integrated components as they are in the field. However, when mounted on a test bench the nacelle is not on the top of a tower and does not have blades attached to it--this is a form of abstraction. This paper aims to quantify the influence of such an abstraction on the dynamic response of the nacelle through amore » series of simulation case studies. The responses of several nacelle components are studied including the main bearing, main shaft, gearbox supports, generator, and yaw bearing interface. Results are presented to highlight the differences in the dynamic response of the nacelle caused by the abstraction. Additionally, the authors provide recommendations for mitigating the effects of the abstraction.« less
2017-05-05
Kennedy Space Center Associate Director Kelvin Manning addresses about 40 Brevard County high school seniors regarding NASA's and Kennedy’s roles and missions during Brevard Top Scholars Day at Kennedy Space Center on May 5. Kennedy's Office of Education coordinated the event that featured a special behind-the-scenes tour of Kennedy, including prototype shops, cryogenic labs and facilities such as the Vehicle Assembly Building and the Launch Control Center firing rooms.
Women at the Top: Powerful Leaders Define Success as Work + Family in a Culture of Gender
ERIC Educational Resources Information Center
Cheung, Fanny M.; Halpern, Diane F.
2010-01-01
How do women rise to the top of their professions when they also have significant family care responsibilities? This critical question has not been addressed by existing models of leadership. In a review of recent research, we explore an alternative model to the usual notion of a Western male as the prototypical leader. The model includes (a)…
Two modes resonant combined motion for insect wings kinematics reproduction and lift generation
NASA Astrophysics Data System (ADS)
Faux, D.; Thomas, O.; Cattan, E.; Grondel, S.
2018-03-01
This paper presents an original concept using a two resonant vibration modes combined motion to reproduce insect wings kinematics and generate lift. The key issue is to design the geometry and the elastic characteristics of artificial wings such that a combination of flapping and twisting motions in a quadrature phase shift could be obtained. This qualitatively implies to bring the frequencies of the two resonant modes closer. For this purpose, a polymeric prototype was micromachined with a wingspan of 3 cm, flexible wings and a single actuator. An optimal wings configuration was determined with a modeling and validated through experimental modal analyses to verify the proximity of the two modes frequencies. A dedicated lift force measurement bench was developed and used to demonstrate a lift force equivalent to the prototype weight. Finally, at the maximum lift frequency, high-speed camera measurements confirmed a kinematics of the flexible wings with flapping and twisting motions in phase quadrature as expected.
Space shuttle prototype check valve development
NASA Technical Reports Server (NTRS)
Tellier, G. F.
1976-01-01
Contaminant-resistant seal designs and a dynamically stable prototype check valve for the orbital maneuvering and reaction control helium pressurization systems of the space shuttle were developed. Polymer and carbide seal models were designed and tested. Perfluoroelastomers compatible with N2O4 and N2H4 types were evaluated and compared with Teflon in flat and captive seal models. Low load sealing and contamination resistance tests demonstrated cutter seal superiority over polymer seals. Ceramic and carbide materials were evaluated for N2O4 service using exposure to RFNA as a worst case screen; chemically vapor deposited tungsten carbide was shown to be impervious to the acid after 6 months immersion. A unique carbide shell poppet/cutter seat check valve was designed and tested to demonstrate low cracking pressure ( 2.0 psid), dynamic stability under all test bench flow conditions, contamination resistance (0.001 inch CRES wires cut with 1.5 pound seat load) and long life of 100,000 cycles (leakage 1.0 scc/hr helium from 0.1 to 400 psig).
Stueber, Dirk; Jehle, Stefan
2017-07-01
Prevalent polymorphism and complicated phase behavior of active pharmaceutical ingredients (APIs) often result in remarkable differences in the respective biochemical and physical API properties. Consequently, API form characterization and quantification play a central role in the pharmaceutical industry from early drug development to manufacturing. Here we present a novel and proficient quantification protocol for solid mixtures (qSRC) based on the measurement and mathematical fitting of T 1 nuclear magnetic resonance (NMR) saturation recovery curves collected on a bench top time-domain NMR instrument. The saturation recovery curves of the relevant pure components are used as fingerprints. Employing a bench top NMR instrument possesses clear benefits. These instruments exhibit a small footprint, do not present any special requirements on lab space, and required sample handling is simple and fast. The qSRC analysis can easily be conducted in a conventional laboratory setting as well as in an industrial production environment, making it a versatile tool with the potential for widespread application. The accuracy and efficiency of the qSRC method is illustrated using 1 H and 19 F T 1 data of selected pharmaceutical model compounds, as well as utilizing 1 H T 1 data of an actual binary API anhydrous polymorph system of a Merck & Co., Inc. compound formerly developed as a hepatitis C virus drug. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Rinne revisited: steel versus aluminum tuning forks.
MacKechnie, Cheryl A; Greenberg, Jesse J; Gerkin, Richard C; McCall, Andrew A; Hirsch, Barry E; Durrant, John D; Raz, Yael
2013-12-01
(1) Determine whether tuning fork material (aluminum vs stainless steel) affects Rinne testing in the clinical assessment of conductive hearing loss (CHL). (2) Determine the relative acoustic and mechanical outputs of 512-Hz tuning forks made of aluminum and stainless steel. Prospective, observational. Outpatient otology clinic. Fifty subjects presenting May 2011 to May 2012 with negative or equivocal Rinne in at least 1 ear and same-day audiometry. Rinne test results using aluminum and steel forks were compared and correlated with the audiometric air-bone gap. Bench top measurements using sound-level meter, microphone, and artificial mastoid. Patients with CHL were more likely to produce a negative Rinne test with a steel fork than with an aluminum fork. Logistic regression revealed that the probability of a negative Rinne reached 50% at a 19 dB air-bone gap for stainless steel versus 27 dB with aluminum. Bench top testing revealed that steel forks demonstrate, in effect, more comparable air and bone conduction efficiencies while aluminum forks have relatively lower bone conduction efficiency. We have found that steel tuning forks can detect a lesser air-bone gap compared to aluminum tuning forks. This is substantiated by observations of clear differences in the relative acoustic versus mechanical outputs of steel and aluminum forks, reflecting underlying inevitable differences in acoustic versus mechanical impedances of these devices, and thus efficiency of coupling sound/vibratory energy to the auditory system. These findings have clinical implications for using tuning forks to determine candidacy for stapes surgery.
Hower, J.C.; Ruppert, L.F.; Williams, D.A.
2002-01-01
The Duckmantian-aged Amos coal bed is a thin (<51 cm) coal bed that occurs in lobate southwest-trending pods separated by thin sandstones in the Western Kentucky coalfield. The coal bed, which is comprised of up to two benches and a rider coal, is low in ash yield (<6%) and sulfur content (<1%). The coal tends to be thin (<40 cm), but it was heavily mined in the 1980s because it could be combusted as mined. Geochemical analysis of the Amos coal bed shows higher concentrations of B and Ge than other Western Kentucky coal beds. High total B concentrations as well as high B/Be, both considered to be indicators of marine environments, increase toward the top of the coal bed. Most of the B values for the Amos samples range from 66 to 103 ppm (whole coal basis) indicating deposition in a brackish environment. High Ge concentrations in coals have been considered to be a function of seam thickness and proximity to the top and bottom of the coal bed. Thin coals, such as the Amos, are dominated by the coal bed margins and, therefore, have a tendency to have relatively high Ge concentrations. In the case of the Amos coal bed, the lower bench has a higher Ge content, suggesting that the substrate was a more important source of Ge than the roof rock. ?? 2002 Elsevier Science B.V. All rights reserved.
Rathee, S; Tu, D; Monajemi, T T; Rickey, D W; Fallone, B G
2006-04-01
We describe the components of a bench-top megavoltage computed tomography (MVCT) scanner that uses an 80-element detector array consisting of CdWO4 scintillators coupled to photodiodes. Each CdWO4 crystal is 2.75 x 8 x 10 mm3. The detailed design of the detector array, timing control, and multiplexer are presented. The detectors show a linear response to dose (dose rate was varied by changing the source to detector distance) with a correlation coefficient (R2) nearly unity with the standard deviation of signal at each dose being less than 0.25%. The attenuation of a 6 MV beam by solid water measured by this detector array indicates a small, yet significant spectral hardening that needs to be corrected before image reconstruction. The presampled modulation transfer function is strongly affected by the detector's large pitch and a large improvement can be obtained by reducing the detector pitch. The measured detective quantum efficiency at zero spatial frequency is 18.8% for 6 MV photons which will reduce the dose to the patient in MVCT applications. The detector shows a less than a 2% reduction in response for a dose of 24.5 Gy accumulated in 2 h; however, the lost response is recovered on the following day. A complete recovery can be assumed within the experimental uncertainty (standard deviation <0.5%); however, any smaller permanent damage could not be assessed.
System analysis of graphics processor architecture using virtual prototyping
NASA Astrophysics Data System (ADS)
Hancock, William R.; Groat, Jeff; Steeves, Todd; Spaanenburg, Henk; Shackleton, John
1995-06-01
Honeywell has been actively involved in the definition of the next generation display processors for military and commercial cockpits. A major concern is how to achieve super graphics workstation performance in avionics application. Most notable are requirements for low volume, low power, harsh environmental conditions, real-time performance and low cost. This paper describes the application of VHDL to the system analysis tasks associated with achieving these goals in a cost effective manner. The paper will describe the top level architecture identified to provide the graphical and video processing power needed to drive future high resolution display devices and to generate more natural panoramic 3D formats. The major discussion, however, will be on the use of VHDL to model the processing elements and customized pipelines needed to realize the architecture and for doing the complex system tradeoff studies necessary to achieve a cost effective implementation. New software tools have been developed to allow 'virtual' prototyping in the VHDL environment. This results in a hardware/software codesign using VHDL performance and functional models. This unique architectural tool allows simulation and tradeoffs within a standard and tightly integrated toolset, which eventually will be used to specify and design the entire system from the top level requirements and system performance to the lowest level individual ASICs. New processing elements, algorithms, and standard graphical inputs can be designed, tested and evaluated without the costly hardware prototyping using the innovative 'virtual' prototyping techniques which are evolving on this project. In addition, virtual prototyping of the display processor does not bind the preliminary design to point solutions as a physical prototype will. when the development schedule is known, one can extrapolate processing elements performance and design the system around the most current technology.
NASA Astrophysics Data System (ADS)
Flude, Stephanie; Haschke, Michael; Tagle, Roald; Storey, Michael
2013-04-01
X-Ray Fluorescence (XRF) has long been used to provide valuable geochemical analysis of bulk rock samples in geological studies. However, it is a destructive technique, requiring samples to be homogenised by grinding to a fine powder and formed into a compacted pellet, or fused glass disk and the resulting sample has to be completely flat for reliable analysis. Until recently, non-destructive, high spatial resolution µ- XRF analysis was possible only at specialised Synchrotron radiation facilities, where high excitation beam energies are possible and specialised X-ray focussing optical systems are available. Recently, a number of bench-top µ-XRF systems have become available, allowing easy, rapid and non-destructive geochemical analysis of various materials. We present a number of examples of how the new bench-top M4 Tornado µ-XRF system, developed by Bruker Nano, can be used to provide valuable geochemical information on geological samples. Both quantitative and qualitative (in the form of X-Ray area-maps) data can be quickly and easily acquired for a wide range of elements (as light as Na, using a vacuum), with minimal sample preparation, using an X-Ray spot size as low as 25 µm. Large specimens up to 30 cm and 5 kg in weight can be analysed due to the large sample chamber, allowing non-destructive characterisation of rare or valuable materials. This technique is particularly useful in characterising heterogeneous samples, such as drill cores, sedimentary and pyroclastic rocks containing a variety of clasts, lavas sourced from mixed and mingled magmas, mineralised samples and fossils. An obvious application is the ability to produce element maps or line-scans of minerals, allowing zoning of major and trace elements to be identified and thus informing on crystallisation histories. An application of particular interest to 40Ar/39Ar geochronologists is the ability to screen and assess the purity of mineral separates, or to characterise polished slabs for subsequent in-situ 40Ar/39Ar laser probe analysis; in the past such samples may have been characterised using SEM, but recent work [1] suggests that charging of a sample during electron-beam excitation can cause redistribution of K, thus disturb the 40Ar/39Ar system. Finally, we assess data accuracy and precision by presenting quantitative analyses of a number of standards. [1] Flude et al., The effect of SEM imaging on the Ar/Ar system in feldspars, V51C-2215 Poster, AGU Fall Meeting 2010
The Integration Process of Very Thin Mirror Shells with a Particular Regard to Simbol-X
NASA Astrophysics Data System (ADS)
Basso, S.; Pareschi, G.; Tagliaferri, G.; Mazzoleni, F.; Valtolina, R.; Citterio, O.; Conconi, P.
2009-05-01
The optics of Simbol-X are very thin compared to previous X-ray missions (like XMM). Therefore their shells floppy and are unable to maintain the correct shape. To avoid the deformations of their very thin X-ray optics during the integration process we adopt two stiffening rings with a good roundness. In this article the procedure used for the first three prototypes of the Simbol-X optics is presented with a description of the problems involved and with an analysis of the degradation of the performances during the integration. This analysis has been performed with the UV vertical bench measurements at INAF-OAB.
NASA Technical Reports Server (NTRS)
Boyle, Robert M.; Mitchell, Kathryn; Allton, Charles; Ju, Hsing
2011-01-01
The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a spacesuit while the spacesuit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a spacesuit prototype using the pressure differentials of the spacecraft. This test will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, the suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents design of a human rated second generation suitport, modifications to the JSC human rated chamber B to accept a suitport, and a compatible space suit to support pressurized human donning of the pressurized suit through a suitport. Design challenges and solutions and compromises required to develop the system are presented. Initial human testing results are presented.
Zhang, Hong; Ren, Lei; Kong, Vic; Giles, William; Zhang, You; Jin, Jian-Yue
2016-01-01
A preobject grid can reduce and correct scatter in cone beam computed tomography (CBCT). However, half of the signal in each projection is blocked by the grid. A synchronized moving grid (SMOG) has been proposed to acquire two complimentary projections at each gantry position and merge them into one complete projection. That approach, however, suffers from increased scanning time and the technical difficulty of accurately merging the two projections per gantry angle. Herein, the authors present a new SMOG approach which acquires a single projection per gantry angle, with complimentary grid patterns for any two adjacent projections, and use an interprojection sensor fusion (IPSF) technique to estimate the blocked signal in each projection. The method may have the additional benefit of reduced imaging dose due to the grid blocking half of the incident radiation. The IPSF considers multiple paired observations from two adjacent gantry angles as approximations of the blocked signal and uses a weighted least square regression of these observations to finally determine the blocked signal. The method was first tested with a simulated SMOG on a head phantom. The signal to noise ratio (SNR), which represents the difference of the recovered CBCT image to the original image without the SMOG, was used to evaluate the ability of the IPSF in recovering the missing signal. The IPSF approach was then tested using a Catphan phantom on a prototype SMOG assembly installed in a bench top CBCT system. In the simulated SMOG experiment, the SNRs were increased from 15.1 and 12.7 dB to 35.6 and 28.9 dB comparing with a conventional interpolation method (inpainting method) for a projection and the reconstructed 3D image, respectively, suggesting that IPSF successfully recovered most of blocked signal. In the prototype SMOG experiment, the authors have successfully reconstructed a CBCT image using the IPSF-SMOG approach. The detailed geometric features in the Catphan phantom were mostly recovered according to visual evaluation. The scatter related artifacts, such as cupping artifacts, were almost completely removed. The IPSF-SMOG is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.
Light yield and energy resolution studies for SoLid phase 1
NASA Astrophysics Data System (ADS)
Boursette, Delphine;
2017-09-01
The SoLid experiment is searching for sterile neutrinos at a nuclear research reactor. It looks for inverse beta decays (producing a positron and a neutron in delayed coincidence) with a very segmented detector made of thousands of scintillating cubes. SoLid has a very innovative hybrid technology with two different scintillators which have different light emissions: polyvynil-toluene cubes (PVT) to detect the positrons and 6LiF:ZnS sheets on two faces of each PVT cube to detect the neutrons. It allows us to do an efficient pulse shape analysis to identify the signals from neutrons and positrons. The 288 kg detector prototype (SM1) took data in 2015. It demonstrated the detection principle and background rejection efficiency. The construction of SoLid phase I (˜ 1.5 t) has now started. To improve the energy resolution of SoLid phase I, we have tried to increase the light yield studying separately the two scintillators: PVT and ZnS. A test bench has been built to fully characterize and improve the neutron detection with the ZnS using an AmBe source. To study the positron light yield on the PVT, we have built another test bench with a 207Bi source. We have improved the design of the cubes, their wrapping or the type and the configuration of the fibers. We managed to increase the PVT light yield by about 66 % and improve the resolution of the positron energy on the test bench from 21 % to 16 % at 1 MeV.
The Enigmatic Bench Unit of Endeavour Crater Rim in Meridiani Planum, Mars
NASA Astrophysics Data System (ADS)
Ruff, S. W.
2013-12-01
For the first 2680 sols of its mission, the Mars Exploration Rover Opportunity traversed across essentially the same rocks: sulfur-rich sandstones known as the Burns formation. On August 8, 2011 Opportunity completed a ~21 km traverse from Victoria crater to the rim of the ~22 km diameter Endeavour crater where it crossed a slightly raised smooth bench unit that surrounds an interior core of higher standing and more rugged terrain on a rim segment named Cape York. As recognized by its distinctive morphologic character evident in orbital images, the inward sloping bench feature is found associated with portions of other segments of the discontinuous raised rim of Endeavour crater. Viewed by Opportunity, it appears as platy, fractured, relatively light-toned outcrop that is fine-grained, lacks hematite concretions and in places hosts veins of Ca- and S-rich composition, likely due to precipitation of gypsum in fractures that cut the bench unit (1). The bench outcrop target named Grasberg included a grind using the Rock Abrasion Tool (RAT) to obtain a cleaner surface for the Alpha Particle X-ray Spectrometer chemistry measurement compared with the initially investigated target named Deadwood. In addition to its greater strength than Burns formation as determined by the RAT grind operation, Grasberg and other examples of the bench unit have lower S, higher Cl and other elemental characteristics that depart from typical Burns formation. Thus the 'Grasberg unit' clearly represents a distinct rock type compared to the Meridiani plains. A second unit makes up the exposed core of the Cape York rim segment. Known as Shoemaker formation, it is composed of breccias that are recognized as a suevite deposit produced from the Endeavour impact event (1). The Shoemaker formation appears to be onlapped by the Grasberg unit with Burns formation onlapping it (1). However, a well-exposed section observed in a wedge-shaped fracture known as Whim Creek on the northeast portion of the Cape York bench clearly presents Grasberg rocks above Burns rocks. Erosion of a plunging synclinal form could explain this apparent inverted relationship, or it reveals that the Grasberg unit is younger than Burns formation. But this latter interpretation implies that Grasberg rocks, which have been observed only at the Endeavour rim, have been stripped off of Burns formation everywhere else. The Grasberg bench unit has recently been encountered in an isthmus setting between two low knobs of presumed Shoemaker formation called Nobbys Head and Sutherland Point just south of Cape York. The isthmus also presents Grasberg as topographically elevated above the Burns formation rocks. Despite its broad, smooth exposure, no remnants of Burns formation have been found on top of Grasberg at this location or anywhere on the Cape York bench. So the stratigraphic relationship between Grasberg and Burns rocks remains enigmatic. At the time of writing, Opportunity is at the edge of Solander Point, another bench feature on the northern tip of a rim segment known as Cape Tribulation. The erosional expression of this example appears different from those examined previously and perhaps offers the best chance to understand stratigraphic relationships. 1. S. W. Squyres et al., Ancient impact and aqueous processes at Endeavour Crater, Mars. Science 336, 570 (2012).
Zero voltage mass spectrometry probes and systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cooks, Robert Graham; Wleklinski, Michael Stanley; Bag, Soumabha
The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.
Engagement of Metal Debris into a Gear Mesh
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.; Krantz, Timothy L.
2010-01-01
A series of bench top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock, and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined.
Intradermal needle-free powdered drug injection by a helium-powered device.
Liu, John; Hogan, N Catherine; Hunter, Ian W
2012-01-01
We present a new method for needle-free powdered drug injection via a bench-top gas-powered device. This injector provides an alternative method of vaccine delivery to address the cold chain problem--the cost and risk of transporting temperature sensitive vaccines to developing countries. The device houses interchangeable nozzle inserts to vary orifice geometries and is capable of delivering polymer beads (1-5 µm diameter) into the dermal layer of porcine tissue. Results for injection shape and injection depth versus nozzle orifice diameter demonstrate the device's controllability.
Extracorporeal CO2 removal by hemodialysis: in vitro model and feasibility.
May, Alexandra G; Sen, Ayan; Cove, Matthew E; Kellum, John A; Federspiel, William J
2017-12-01
Critically ill patients with acute respiratory distress syndrome and acute exacerbations of chronic obstructive pulmonary disease often develop hypercapnia and require mechanical ventilation. Extracorporeal carbon dioxide removal can manage hypercarbia by removing carbon dioxide directly from the bloodstream. Respiratory hemodialysis uses traditional hemodialysis to remove CO 2 from the blood, mainly as bicarbonate. In this study, Stewart's approach to acid-base chemistry was used to create a dialysate that would maintain blood pH while removing CO 2 as well as determine the blood and dialysate flow rates necessary to remove clinically relevant CO 2 volumes. Bench studies were performed using a scaled down respiratory hemodialyzer in bovine or porcine blood. The scaling factor for the bench top experiments was 22.5. In vitro dialysate flow rates ranged from 2.2 to 24 mL/min (49.5-540 mL/min scaled up) and blood flow rates were set at 11 and 18.7 mL/min (248-421 mL/min scaled up). Blood inlet CO 2 concentrations were set at 50 and 100 mmHg. Results are reported as scaled up values. The CO 2 removal rate was highest at intermittent hemodialysis blood and dialysate flow rates. At an inlet pCO 2 of 50 mmHg, the CO 2 removal rate increased from 62.6 ± 4.8 to 77.7 ± 3 mL/min when the blood flow rate increased from 248 to 421 mL/min. At an inlet pCO 2 of 100 mmHg, the device was able to remove up to 117.8 ± 3.8 mL/min of CO 2 . None of the test conditions caused the blood pH to decrease, and increases were ≤0.08. When the bench top data is scaled up, the system removes a therapeutic amount of CO 2 standard intermittent hemodialysis flow rates. The zero bicarbonate dialysate did not cause acidosis in the post-dialyzer blood. These results demonstrate that, with further development, respiratory hemodialysis can be a minimally invasive extracorporeal carbon dioxide removal treatment option.
NASA Technical Reports Server (NTRS)
Olson, S. L.; Beeson, H.; Haas, J. P.
2003-01-01
The objective of this project is to modify the standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. This apparatus will allow us to conduct normal gravity experiments that accurately and quantitatively evaluate a material's flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire configuration that provides a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by a flame in a spacecraft or extraterrestrial gravity level. Prototype unit testing results are presented in this paper. Ignition delay times and regression rates for PMMA are presented over a range of radiant heat flux levels and equivalent stretch rates which demonstrate the ability of ELSA to simulate key features of microgravity and extraterrestrial fire behavior.
NASA Astrophysics Data System (ADS)
Diekmann, Christian; Troebs, Michael; Steier, Frank; Bykov, Iouri; Heinzel, Gerhard; Danzmann, Karsten
The space-based interferometric gravitational-wave detector Laser Interferometer Space An-tenna (LISA) requires interferometry with subpicometer and nanoradian sensitivity in the fre-quency range between 3 mHz and 1 Hz. Currently, a first prototype of the optical bench for LISA is being designed. We report on a pre-experiment with the aim to demonstrate the required sensitivities and to thoroughly characterise the equipment. For this purpose, a quasi-monolithic optical setup has been built with two Mach-Zehnder interferometers (MZI) on an optical bench made of zerodur. In a first step the relative length change between these two MZI will be measured with a heterodyne modulation scheme in the kHz-range and the angle between two laser beams will be read out via quadrant photodiodes and a technique called differential wavefront sensing. These techniques have already been used for the LISA prede-cessor mission LISA Pathfinder and their sensitivity needs to be further improved to fulfill the requirements of the LISA mission. We describe the experiment and the characterization of the basic components. Measurements of the length and angular noise will be presented.
Mechanisms and actuators for rotorcraft blade morphing
NASA Astrophysics Data System (ADS)
Vocke, Robert D., III
The idea of improved fight performance through changes in the control surfaces dates back to the advent of aviation with the Wright brothers' pioneering work on "wing warping," but it was not until the recent progress in material and actuator development that such control surfaces seemed practical for modern aircraft. This has opened the door to a new class of aircraft that have the ability to change shape or morph, which are being investigated due to the potential to have a single platform serve multiple mission objectives, as well as improve performance characteristics. While the majority of existing research for morphing aircraft has focused on fixedwing aircraft, rotary-wing aircraft have begun to receive more attention. The purpose of this body of work is to investigate the current state of morphing actuation technology for rotorcraft and improve upon it. Specifically, this work looks at two types of morphing: Pneumatic Artificial Muscle (PAM) actuated trailing edge flaps and conformal variable diameter morphing. First, active camber changes through the use of PAM powered trailing edge flaps were investigated due to the potential for reductions in power requirements and vibration/noise levels. A PAM based antagonistic actuation system was developed utilizing a novel combination of mechanism geometry and PAM bias contraction optimization to overcome the natural extension stiffening characteristics of PAMs. In open-loop bench-top testing against a "worst-case" constant torsional loading, the system demonstrated actuation authority suitable for both primary control and vibration/noise reduction. Additionally, closed-loop test data indicated that the system was capable of tracking complex waveforms consistent with those needed for rotorcraft control. This system demonstrated performance on-par with the state of the art pneumatic trailing edge flap actuators, yet with a much smaller footprint and impact on the rotor-blade. The second morphing system developed in this work is a conformal variable diameter rotor system suitable for implementation on a modern tilt-rotor aircraft, which can reduce power requirements in both cruise and hover configurations. An initial prototype variable span airfoil was constructed using a silicone elastomer matrix composite skin and a plastic rapid prototyped morphing substructure. Benchtop and wind tunnel tests verified the ability of this system to increase active wing area by 100%. The prototype technology was then matured for use in the harsh rotor blade environment, with a much stiffer polyurethane skin and a titanium substructure. Coupon testing verified the efficacy of this approach, and a final conceptual design was completed using the stiffness-tuning characteristics of the morphing substructure to create a self-actuating morphing blade tip.
Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage
NASA Astrophysics Data System (ADS)
Zheng, Y.; Yang, Y.; Rogowska, M.; Gundlach, C.
2017-09-01
To achieve the 2°C target made in the 2016 Paris Agreement, it is essential to reduce the emission of CO2 into the atmosphere. Carbon Capture and Storage (CCS) has been given increasing importance over the last decade. One of the suggested methods for CCS is to inject CO2 into geologic settings such as the carbonate reservoirs in the North Sea. The final aim of our project is to find out how to control the evolution of petrophysical parameters during CO2 injection using an optimal combination of flow rate, injection pressure and chemical composition of the influent. The first step to achieve this is to find a suitable condition to create a stable 3D space in carbonate rock by injecting liquid to prepare space for the later CO2 injection. Micro-CT imaging is a non-destructive 3D method that can be used to study the property changes of carbonate rocks during and after CO2 injection. The advance in lab source based micro-CT has made it capable of in situ experiments. We used a commercial bench top micro-CT (Zeiss Versa XRM410) to study the microstructure changes of chalk during liquid injection. Flexible temporal CT resolution is essential in this study because that the time scales of coupled physical and chemical processes can be very different. The results validated the feasibility of using a bench top CT system with a pressure cell to monitor the mesoscale multiphase interactions in chalk.
NASA Astrophysics Data System (ADS)
Civitani, Marta
2009-08-01
Focusing X-ray telescopes with imaging capabilities, like SIMBOL-X, HEXISAT and IXO, are characterized by very long focal lengths, greater than 10m. The constraints posed by the launchers on the maximum dimensions of a payload, make necessary using alternatives to monolithic telescopes. One possibility is that the mirror and the detectors are carried by two separate spacecrafts that fly in formation. Another is placing the detector module on a bench that will be extended once in final orbit. In both the case the system will be subjected to deformation due the relative movement of the mirrors with respect to detectors. In one case the deformation will be due to the correction on the position and attitude of the detector spacecraft to maintain the formation with the mirror spacecraft, while in the other to oscillations of the detectors on the top of the bench. The aim of this work is to compare the behavior of the system in the two different configurations and to evaluate the performances of the on board metrology systems needed not to degrade the telescope angular resolution.
Nambu mechanism of dynamical symmetry breaking by the top quark
NASA Astrophysics Data System (ADS)
Pham, Xuan-Yem
1990-05-01
It may be possible that the gauge symmetry breaking of the standard electroweak interactions is not due to the elementary scalar Higgs fields but has a dynamic origin intimately involving the top quark. A prototype of this dynamical scenario is the Nambu and Jona-Lasinio model in which both the top quark and the gauge bosons become massive by some strong attractive nonlinear interactions similar to the gap energy produced in BCS superconductivity. Self-consistent equations for the charged Goldstone boson and for the vector meson are used to get an upper bound for the top quark mass. In the bubble approximation of keeping only fermion loops, we obtain an equation relating the top quark mass to the W boson one; from the top mass is found to be around 84 GeV. Its typical dominant decay mode t→W+s then follows. Also discussed are distinctive signatures of the scalar overlinett bound state identified as the physical Higgs particle whose mass is twice that of the top quark.
NASA Technical Reports Server (NTRS)
Szczur, Martha R.
1989-01-01
The Transportable Applications Environment Plus (TAE Plus), developed by NASA's Goddard Space Flight Center, is a portable User Interface Management System (UIMS), which provides an intuitive WYSIWYG WorkBench for prototyping and designing an application's user interface, integrated with tools for efficiently implementing the designed user interface and effective management of the user interface during an application's active domain. During the development of TAE Plus, many design and implementation decisions were based on the state-of-the-art within graphics workstations, windowing system and object-oriented programming languages. Some of the problems and issues experienced during implementation are discussed. A description of the next development steps planned for TAE Plus is also given.
Balances for the measurement of multiple components of force in flows of a millisecond duration
NASA Technical Reports Server (NTRS)
Mee, D. J.; Daniel, W. J.; Tuttle, S. L.; Simmons, J. M.
1995-01-01
This paper reports a new balance for the measurement of three components of force - lift, drag and pitching moment - in impulsively starting flows which have a duration of about one millisecond. The basics of the design of the balance are presented and results of tests on a 15 deg semi-angle cone set at incidence in the T4 shock tunnel are compared with predictions. These results indicate that the prototype balance performs well for a 1.9 kg, 220 mm long model. Also presented are results from initial bench tests of another application of the deconvolution force balance to the measurement of thrust produced by a 2D scramjet nozzle.
TF34 convertible engine control system design
NASA Technical Reports Server (NTRS)
Gilmore, D. R., Jr.
1984-01-01
The characteristics of the TF34 convertible engine, capable of producing shaft power, thrust, or a combination of both, is investigated with respect to the control system design, development, bench testing, and the anticipated transient response during engine testing at NASA. The modifications to the prototype standard TF34-GE-400 turbofan, made primarily in the fan section, consist of the variable inlet guide vanes and variable exit guide vanes. The control system was designed using classical frequency domain techniques and was based on the anticipated convertible/VTOL airframe requirements. The engine has been run in the fan mode and in the shaft mode, exhibiting a response of 0.14 second to a 5-percent thrust change.
ERIC Educational Resources Information Center
Maule, R. William
1994-01-01
Discusses prototype information infrastructure projects in northern California's Silicon Valley. The strategies of the public and private telecommunications carriers vying for backbone services and industries developing end-user infrastructure technologies via office networks, set-top box networks, Internet multimedia, and "smart homes"…
Precise Truss Assembly Using Commodity Parts and Low Precision Welding
NASA Technical Reports Server (NTRS)
Komendera, Erik; Reishus, Dustin; Dorsey, John T.; Doggett, W. R.; Correll, Nikolaus
2014-01-01
Hardware and software design and system integration for an intelligent precision jigging robot (IPJR), which allows high precision assembly using commodity parts and low-precision bonding, is described. Preliminary 2D experiments that are motivated by the problem of assembling space telescope optical benches and very large manipulators on orbit using inexpensive, stock hardware and low-precision welding are also described. An IPJR is a robot that acts as the precise "jigging", holding parts of a local structure assembly site in place, while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (for this prototype, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. The analysis of the assembly error and the results of building a square structure and a ring structure are discussed. Options for future work, to extend the IPJR paradigm to building in 3D structures at micron precision are also summarized.
Bostick, N.H.; Betterton, W.J.; Gluskoter, H.J.; Nazrul, Islam M.
1991-01-01
Drilling through Quaternary alluvium and Tertiary cover at low-gravity anomalies in northwestern Bangladesh showed the presence of Permian sedimentary rocks in depressions that may be as much as a thousand meters deep in the crystalline basement. These Permian strata include low-sulfur, high-volatile bituminous coals in beds as thick as 15 m. The maceral group composition of these coals was determined by semiautomated reflectance scanning with a motorized microscope stage, rather than by point counting. This method was chosen to give objectively recorded raw analytical data and to provide a graphical picture of each sample. The coals are mostly "Gondwana" type (poorly layered "plum pudding" with abundant minerals and inertinite in a vitrinite groundmass) that would be classed as semi-dull (inerto-gelitite) coals. However, six samples have more than 70% vitrinite. None of the samples would be classed as sapropelic (liptinitic). The upper, middle, and lower main seams in borehole GDH-45 were sampled in 10 benches (0.1-3 m thick) each. Inertinite ranges from 7 to 100 vol% (mineral free basis) in individual benches, but composite seam averages are 41, 54 and 67%. Inertinite increases toward the top of two main seams so the bottom would yield the most valuable first mine slices. Some benches with extremely high inertinite content, such as the top 7 m of the lower thick seam, might be mined specially for blending with foreign low-inert coals to increase coke strength. The free swelling index reaches 7.5 in several vitrinite-rich benches, which can indicate good coking coal. Much of the vitrinite is fluorescent, which indicates secondary bituminization characteristic of vitrinite in good coking coals. Ash yields range from 8 to 52%, with composite seam averages of 15, 14 and 24%. Rare visible pyrite is in veinlets or small nodules; framboids and dispersed pyrite are absent. In borehole GDH-40 near Barapukuria (200-500 m depth), the mean random reflectance of vitrinite "A" ranges from 0.60 to 0.80% Ro and vitrinite "B" ranges from 0.55 to 0.65%. In borehole GDH-45 near Khalaspir (287-442 m), the reflectance of vitrinite ranges from 0.79 to 0.94%. In individual cases, the vitrinite is difficult to define because of semivitrinite at higher reflectance (forming a separate peak on several reflectograms) and because of surface bitumen films or resinous (?) inclusions at lower reflectance. On the basis of vitrinite reflectance, the coals can be considered to have entered the "main phase of bitumen generation" of organic thermal maturation as understood in petroleum geochemistry. ?? 1991.
Polarimetric glucose sensing using Brewster reflection applying a rotating retarder analyzer
NASA Astrophysics Data System (ADS)
Boeckle, Stefan; Rovati, Luigi L.; Ansari, Rafat R.
2003-10-01
Previously, we proposed a polarimetric method, that exploits the Brewster-reflection with the final goal of application to the human eye (reflection off the eye lens) for non-invasive glucose sensing. The linearly polarized reflected light of this optical scheme is rotated by the glucose molecules present in the aqueous humor, thus carries the blood glucose concentration information. A proof-of-concept experimental bench-top setup is presented, applying a multi-wavelength true phase measurement approach and a rotating phase retarder as an analyzer to measure the very small rotation angles and the complete polarization state of the measurement light.
Simulation in Surgical Education
de Montbrun, Sandra L.; MacRae, Helen
2012-01-01
The pedagogical approach to surgical training has changed significantly over the past few decades. No longer are surgical skills solely acquired through a traditional apprenticeship model of training. The acquisition of many technical and nontechnical skills is moving from the operating room to the surgical skills laboratory through the use of simulation. Many platforms exist for the learning and assessment of surgical skills. In this article, the authors provide a broad overview of some of the currently available surgical simulation modalities including bench-top models, laparoscopic simulators, simulation for new surgical technologies, and simulation for nontechnical surgical skills. PMID:23997671
Design and commissioning of a multi-mode prototype for thermochemical conversion of human faeces.
Jurado, Nelia; Somorin, Tosin; Kolios, Athanasios J; Wagland, Stuart; Patchigolla, Kumar; Fidalgo, Beatriz; Parker, Alison; McAdam, Ewan; Williams, Leon; Tyrrel, Sean
2018-05-01
This article describes the design and commissioning of a micro-combustor for energy recovery from human faeces, which can operate both in updraft and downdraft modes. Energy recovery from faecal matter via thermochemical conversion has recently been identified as a feasible solution for sanitation problems in low income countries and locations of high income countries where access to sewage infrastructures is difficult or not possible. This technology can be applied to waterless toilets with the additional outcome of generating heat and power that can be used to pre-treat the faeces before their combustion and to ensure that the entire system is self-sustaining. The work presented here is framed within the Nano Membrane Toilet (NMT) project that is being carried out at Cranfield University, as part of the Reinvent the Toilet Challenge of the Bill and Melinda Gates Foundation. For this study, preliminary trials using simulant faeces pellets were first carried out to find out the optimum values for the main operating variables at the scale required by the process, i.e. a fuel flowrate between 0.4 and 1.2 g/min of dry faeces. Parameters such as ignition temperature, residence time, and maximum temperature reached, were determined and used for the final design of the bench-scale combustor prototype. The prototype was successfully commissioned and the first experimental results, using real human faeces, are discussed in the paper.
Progress on the PT-1 Prototype Plasmoid Thruster
NASA Technical Reports Server (NTRS)
Eskridge, Richard H.; Martin, Adam K.
2007-01-01
The design and construction of a plasmoid thruster prototype is described. This thruster operates by expelling inductively formed plasmoids at high velocities. These plasmoids are field reversed configuration plasmas which are formed by reversing a magnetic flux frozen in an ionized gas inside a theta-pinch coil. The pinch coil is a unique multi-turn, multi-lead design chosen for optimization of inductance and field uniformity. A table-top bread-board demonstrator has been built at MSFC, and will be delivered to Radiance Technologies Inc. for further testing at the Auburn Space Power Institute.
NGEE Arctic Zero Power Warming PhenoCamera Images, Barrow, Alaska, 2016
Shawn Serbin; Andrew McMahon; Keith Lewin; Kim Ely; Alistair Rogers
2016-11-14
StarDot NetCam SC pheno camera images collected from the top of the Barrow, BEO Sled Shed. The camera was installed to monitor the BNL TEST group's prototype ZPW (Zero Power Warming) chambers during the growing season of 2016 (including early spring and late fall). Images were uploaded to the BNL FTP server every 10 minutes and renamed with the date and time of the image. See associated data "Zero Power Warming (ZPW) Chamber Prototype Measurements, Barrow, Alaska, 2016" http://dx.doi.org/10.5440/1343066.
Eble, C.F.; Pierce, B.S.; Grady, W.C.
2003-01-01
Forty-two bench samples of the Sewickley coal bed were collected from seven localities in the northern Appalachian Basin and analyzed palynologically, petrographically, and geochemically. The Sewickley coal bed occurs in the middle of the Pittsburgh Formation (Monongahela Group) and is of Late Pennsylvanian age. Palynologically, it is dominated by spores of tree ferns. Tree fern spore taxa in the Sewickley include Punctatisporites minutus, Punctatosporites minutus, Laevigatosporites minimus, Spinosporites exiguus, Apiculatasporites saetiger, and Thymospora spp. In fact, Punctatisporites minutus was so abundant that it had to be removed from the standard counts and recorded separately (average 73.2%). Even when Punctatisporites minutus is removed from the counts, tree fern spores still dominate a majority of the assemblages, averaging 64.4%. Among the tree fern spores identified in the Sewickley coal, Thymospora exhibits temporal and spatial abundance variation. Thymospora usually increases in abundance from the base to the top of the bed. Thymospora is also more abundant in columns that are thick (>100 cm) and low in ash yield (< 12.0%, dry basis). Calamite spores (e.g. Calamospora spp., Laevigatosporites minor, and L. vulgaris) are the next most abundant plant group represented in the Sewickley coal, averaging 20%. Contributions from all other plant groups are minor in comparison. Petrographically, the Sewickley coal contains high percentages of vitrinite (average 82.3%, mineral matter-free (mmf)), with structured forms being more common than unstructured forms. In contrast, liptinite and inertinite macerals both occur in low percentages (average 7.7% and 10.0%, respectively). Geochemically, the Sewickley coal has a moderate ash yield (average 12.4%) and high total sulfur content (average 3.4%). Four localities contained a high ash or carbonaceous shale bench. These benches, which may be coeval, are strongly dominated by tree fern spores. Unlike the lower ash benches, they contain low percentages of vitrinite, which mainly occurs as unstructured vitrinite, and higher liptinite and inertinite contents. The accumulated data suggest that the Sewickley paleomire was probably a rheotrophic, planar mire that had a consistent water cover. This is supported by the high vitrinite contents, moderate ash yields, and high total sulfur contents. The high ash and carbonaceous shale benches probably represent either periods of dryness and substrate exposure, or flooding of the mire surface, the duration of which is unknown. ?? 2003 Elsevier B.V. All rights reserved.
Working sketch of an anatomically and optically equivalent physical model eye
NASA Astrophysics Data System (ADS)
Bakaraju, Ravi Chandra; Ehrmann, Klaus; Falk, Darrin; Papas, Eric B.; Ho, Arthur
2009-02-01
Our aim was to fabricate a bench-top physical model eye that closely replicates anatomical and optical properties of the average human eye, and to calibrate and standardize this model to suit normal viewing conditions and subsequently utilize it to understand the optical performance of corrective lens designs; especially multifocal soft contact lenses. Using available normative data on ocular biometrics and Zemax ray-tracing software as a tool, we modeled 25, 45 and 55 year-old average adult human eyes with discrete accommodation levels and pupil sizes. Specifications for the components were established following manufacturing tolerance analyses. The cornea was lathed from an optical material with refractive index of 1.376 @ 589 nm and the crystalline lenses were made of Boston RGP polymers with refractive indices of 1.423 (45 & 55yr) and 1.429 (25yr) @ 589 nm. These two materials served to model the equivalent crystalline lens of the different age-groups. A camera, the acting retina, was hosted on the motor-base having translatory and rotary functions to facilitate the simulation of different states of ametropia and peripheral refraction respectively. We report on the implementation of the first prototype and present some simulations of the optical performance of certain contact lenses with specific levels of ametropia, to demonstrate the potential use of such a physical model eye. On completion of development, calibration and standardization, optical quality assessment and performance predictions of different ophthalmic lenses can be studied in great detail. Optical performance with corrective lenses may be reliably simulated and predicted by customized combined computational and physical models giving insight into the merits and pitfalls of their designs
Self-Powered Wireless Carbohydrate/Oxygen Sensitive Biodevice Based on Radio Signal Transmission
Falk, Magnus; Alcalde, Miguel; Bartlett, Philip N.; De Lacey, Antonio L.; Gorton, Lo; Gutierrez-Sanchez, Cristina; Haddad, Raoudha; Kilburn, Jeremy; Leech, Dónal; Ludwig, Roland; Magner, Edmond; Mate, Diana M.; Conghaile, Peter Ó.; Ortiz, Roberto; Pita, Marcos; Pöller, Sascha; Ruzgas, Tautgirdas; Salaj-Kosla, Urszula; Schuhmann, Wolfgang; Sebelius, Fredrik; Shao, Minling; Stoica, Leonard; Sygmund, Cristoph; Tilly, Jonas; Toscano, Miguel D.; Vivekananthan, Jeevanthi; Wright, Emma; Shleev, Sergey
2014-01-01
Here for the first time, we detail self-contained (wireless and self-powered) biodevices with wireless signal transmission. Specifically, we demonstrate the operation of self-sustained carbohydrate and oxygen sensitive biodevices, consisting of a wireless electronic unit, radio transmitter and separate sensing bioelectrodes, supplied with electrical energy from a combined multi-enzyme fuel cell generating sufficient current at required voltage to power the electronics. A carbohydrate/oxygen enzymatic fuel cell was assembled by comparing the performance of a range of different bioelectrodes followed by selection of the most suitable, stable combination. Carbohydrates (viz. lactose for the demonstration) and oxygen were also chosen as bioanalytes, being important biomarkers, to demonstrate the operation of the self-contained biosensing device, employing enzyme-modified bioelectrodes to enable the actual sensing. A wireless electronic unit, consisting of a micropotentiostat, an energy harvesting module (voltage amplifier together with a capacitor), and a radio microchip, were designed to enable the biofuel cell to be used as a power supply for managing the sensing devices and for wireless data transmission. The electronic system used required current and voltages greater than 44 µA and 0.57 V, respectively to operate; which the biofuel cell was capable of providing, when placed in a carbohydrate and oxygen containing buffer. In addition, a USB based receiver and computer software were employed for proof-of concept tests of the developed biodevices. Operation of bench-top prototypes was demonstrated in buffers containing different concentrations of the analytes, showcasing that the variation in response of both carbohydrate and oxygen biosensors could be monitored wirelessly in real-time as analyte concentrations in buffers were changed, using only an enzymatic fuel cell as a power supply. PMID:25310190
Self-powered wireless carbohydrate/oxygen sensitive biodevice based on radio signal transmission.
Falk, Magnus; Alcalde, Miguel; Bartlett, Philip N; De Lacey, Antonio L; Gorton, Lo; Gutierrez-Sanchez, Cristina; Haddad, Raoudha; Kilburn, Jeremy; Leech, Dónal; Ludwig, Roland; Magner, Edmond; Mate, Diana M; Conghaile, Peter Ó; Ortiz, Roberto; Pita, Marcos; Pöller, Sascha; Ruzgas, Tautgirdas; Salaj-Kosla, Urszula; Schuhmann, Wolfgang; Sebelius, Fredrik; Shao, Minling; Stoica, Leonard; Sygmund, Cristoph; Tilly, Jonas; Toscano, Miguel D; Vivekananthan, Jeevanthi; Wright, Emma; Shleev, Sergey
2014-01-01
Here for the first time, we detail self-contained (wireless and self-powered) biodevices with wireless signal transmission. Specifically, we demonstrate the operation of self-sustained carbohydrate and oxygen sensitive biodevices, consisting of a wireless electronic unit, radio transmitter and separate sensing bioelectrodes, supplied with electrical energy from a combined multi-enzyme fuel cell generating sufficient current at required voltage to power the electronics. A carbohydrate/oxygen enzymatic fuel cell was assembled by comparing the performance of a range of different bioelectrodes followed by selection of the most suitable, stable combination. Carbohydrates (viz. lactose for the demonstration) and oxygen were also chosen as bioanalytes, being important biomarkers, to demonstrate the operation of the self-contained biosensing device, employing enzyme-modified bioelectrodes to enable the actual sensing. A wireless electronic unit, consisting of a micropotentiostat, an energy harvesting module (voltage amplifier together with a capacitor), and a radio microchip, were designed to enable the biofuel cell to be used as a power supply for managing the sensing devices and for wireless data transmission. The electronic system used required current and voltages greater than 44 µA and 0.57 V, respectively to operate; which the biofuel cell was capable of providing, when placed in a carbohydrate and oxygen containing buffer. In addition, a USB based receiver and computer software were employed for proof-of concept tests of the developed biodevices. Operation of bench-top prototypes was demonstrated in buffers containing different concentrations of the analytes, showcasing that the variation in response of both carbohydrate and oxygen biosensors could be monitored wirelessly in real-time as analyte concentrations in buffers were changed, using only an enzymatic fuel cell as a power supply.
Development of integrated semiconductor optical sensors for functional brain imaging
NASA Astrophysics Data System (ADS)
Lee, Thomas T.
Optical imaging of neural activity is a widely accepted technique for imaging brain function in the field of neuroscience research, and has been used to study the cerebral cortex in vivo for over two decades. Maps of brain activity are obtained by monitoring intensity changes in back-scattered light, called Intrinsic Optical Signals (IOS), that correspond to fluctuations in blood oxygenation and volume associated with neural activity. Current imaging systems typically employ bench-top equipment including lamps and CCD cameras to study animals using visible light. Such systems require the use of anesthetized or immobilized subjects with craniotomies, which imposes limitations on the behavioral range and duration of studies. The ultimate goal of this work is to overcome these limitations by developing a single-chip semiconductor sensor using arrays of sources and detectors operating at near-infrared (NIR) wavelengths. A single-chip implementation, combined with wireless telemetry, will eliminate the need for immobilization or anesthesia of subjects and allow in vivo studies of free behavior. NIR light offers additional advantages because it experiences less absorption in animal tissue than visible light, which allows for imaging through superficial tissues. This, in turn, reduces or eliminates the need for traumatic surgery and enables long-term brain-mapping studies in freely-behaving animals. This dissertation concentrates on key engineering challenges of implementing the sensor. This work shows the feasibility of using a GaAs-based array of vertical-cavity surface emitting lasers (VCSELs) and PIN photodiodes for IOS imaging. I begin with in-vivo studies of IOS imaging through the skull in mice, and use these results along with computer simulations to establish minimum performance requirements for light sources and detectors. I also evaluate the performance of a current commercial VCSEL for IOS imaging, and conclude with a proposed prototype sensor.
Jones, Bernard L; Cho, Sang Hyun
2011-06-21
A recent study investigated the feasibility to develop a bench-top x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of gold nanoparticles (GNPs) in vivo using a diagnostic energy range polychromatic (i.e. 110 kVp) pencil-beam source. In this follow-up study, we examined the feasibility of a polychromatic cone-beam implementation of XFCT by Monte Carlo (MC) simulations using the MCNP5 code. In the current MC model, cylindrical columns with various sizes (5-10 mm in diameter) containing water loaded with GNPs (0.1-2% gold by weight) were inserted into a 5 cm diameter cylindrical polymethyl methacrylate phantom. The phantom was then irradiated by a lead-filtered 110 kVp x-ray source, and the resulting gold fluorescence and Compton-scattered photons were collected by a series of energy-sensitive tallies after passing through lead parallel-hole collimators. A maximum-likelihood iterative reconstruction algorithm was implemented to reconstruct the image of GNP-loaded objects within the phantom. The effects of attenuation of both the primary beam through the phantom and the gold fluorescence photons en route to the detector were corrected during the image reconstruction. Accurate images of the GNP-containing phantom were successfully reconstructed for three different phantom configurations, with both spatial distribution and relative concentration of GNPs well identified. The pixel intensity of regions containing GNPs was linearly proportional to the gold concentration. The current MC study strongly suggests the possibility of developing a bench-top, polychromatic, cone-beam XFCT system for in vivo imaging.
Design of a novel prosthetic socket: assessment of the thermal performance.
Webber, Christina M; Davis, Brian L
2015-05-01
Prosthetic liners and sockets insulate the residual limb, causing excessive sweating and concomitant skin maceration. When coupled with atypical loading conditions, further dermatologic problems can arise. This can significantly reduce the quality of life of an amputee patient. Improving the design of the prosthetic socket has been proposed as a means of reestablishing a normal thermal environment around the residual limb. In this study, a prosthetic socket was modified by incorporating a helical cooling channel within the socket wall using additive manufacturing techniques. Two sockets were modeled: a control socket, and a modified socket containing a 0.48 cm diameter cooling channel. Computer simulations and bench-top testing were used to assess the design's ability to create a greater temperature differential across the socket wall. A greater temperature drop across the socket wall suggested that the socket could provide cooling benefits to the residual limb by allowing for heat to be drawn away from the limb. The temperature difference across the socket wall was calculated for both sockets in each aspect of the study. Both socket type (p=0.002) and location on the socket (p=0.014) were statistically significant factors affecting the temperature difference between inner and outer socket walls. Compared with the control socket, the modified socket containing a helical cooling channel exhibited greater temperature differences across its wall of 11.1 °C and 6.4 °C in the computer simulations and bench-top testing, respectively. This finding suggested that socket modifications, such as the cooling channel presented, could provide a beneficial cooling effect to an amputee patient's residual limb. Copyright © 2015 Elsevier Ltd. All rights reserved.
A portable cell-based impedance sensor for toxicity testing of drinking water.
Curtis, Theresa M; Widder, Mark W; Brennan, Linda M; Schwager, Steven J; van der Schalie, William H; Fey, Julien; Salazar, Noe
2009-08-07
A major limitation to using mammalian cell-based biosensors for field testing of drinking water samples is the difficulty of maintaining cell viability and sterility without an on-site cell culture facility. This paper describes a portable automated bench-top mammalian cell-based toxicity sensor that incorporates enclosed fluidic biochips containing endothelial cells monitored by Electric Cell-substrate Impedance Sensing (ECIS) technology. Long-term maintenance of cells on the biochips is made possible by using a compact, self-contained disposable media delivery system. The toxicity sensor monitors changes in impedance of cell monolayers on the biochips after the introduction of water samples. The fluidic biochip includes an ECIS electronic layer and a polycarbonate channel layer, which together reduce initial impedance disturbances seen in commercially available open well ECIS chips caused by the mechanics of pipetting while maintaining the ability of the cells to respond to toxicants. A curve discrimination program was developed that compares impedance values over time between the control and treatment channels on the fluidic biochip and determines if they are significantly different. Toxicant responses of bovine pulmonary artery endothelial cells grown on fluidic biochips are similar to cells on commercially-available open well chips, and these cells can be maintained in the toxicity sensor device for at least nine days using an automated media delivery system. Longer-term cell storage is possible; bovine lung microvessel endothelial cells survive for up to four months on the fluidic biochips and remain responsive to a model toxicant. This is the first demonstration of a portable bench top system capable of both supporting cell health over extended periods of time and obtaining impedance measurements from endothelial cell monolayers after toxicant exposure.
Kersten, Hendrik; Lorenz, Matthias; Brockmann, Klaus J; Benter, Thorsten
2011-06-01
The performance of a KrF* bench top excimer laser and a compact diode pumped UV solid state (DPSS) Nd:YAG laser as photo-ionizing source in LC-APLI MS is compared. The commonly applied bench-top excimer laser, operating at 248 nm, provides power densities of the order of low MW/cm(2) on an illuminated area of 0.5 cm(2) (8 mJ/pulse, 5 ns pulse duration, beam waist area 0.5 cm(2), 3 MW/cm(2)). The DPSS laser, operating at 266 nm, provides higher power densities, however, on a two orders of magnitude smaller illuminated area (60 μJ/pulse, 1 ns pulse duration, beam waist area 2 × 10(-3) cm(2), 30 MW/cm(2)). In a common LC-APLI MS setup with direct infusion of a 10 nM pyrene solution, the DPSS laser yields a significantly smaller ion signal (0.9%) and signal to noise ratio (1.4%) compared with the excimer laser. With respect to the determined low detection limits (LODs) for PAHs of 0.1 fmol using an excimer laser, LODs in DPSS laser LC-APLI MS in the low pmol regime are expected. The advantages of the DPSS laser with respect to applicability (size, cost, simplicity) may render this light source the preferred one for APLI applications not focusing on ultimately high sensitivities. Furthermore, the impact of adjustable ion source parameters on the performance of both laser systems is discussed in terms of the spatial sensitivity distribution described by the distribution of ion acceptance (DIA) measurements. Perspectives concerning the impact on future APLI-MS applications are given.
Silicon Micropore-Based Parallel Plate Membrane Oxygenator.
Dharia, Ajay; Abada, Emily; Feinberg, Benjamin; Yeager, Torin; Moses, Willieford; Park, Jaehyun; Blaha, Charles; Wright, Nathan; Padilla, Benjamin; Roy, Shuvo
2018-02-01
Extracorporeal membrane oxygenation (ECMO) is a life support system that circulates the blood through an oxygenating system to temporarily (days to months) support heart or lung function during cardiopulmonary failure until organ recovery or replacement. Currently, the need for high levels of systemic anticoagulation and the risk for bleeding are main drawbacks of ECMO that can be addressed with a redesigned ECMO system. Our lab has developed an approach using microelectromechanical systems (MEMS) fabrication techniques to create novel gas exchange membranes consisting of a rigid silicon micropore membrane (SμM) support structure bonded to a thin film of gas-permeable polydimethylsiloxane (PDMS). This study details the fabrication process to create silicon membranes with highly uniform micropores that have a high level of pattern fidelity. The oxygen transport across these membranes was tested in a simple water-based bench-top set-up as well in a porcine in vivo model. It was determined that the mass transfer coefficient for the system using SµM-PDMS membranes was 3.03 ± 0.42 mL O 2 min -1 m -2 cm Hg -1 with pure water and 1.71 ± 1.03 mL O 2 min -1 m -2 cm Hg -1 with blood. An analytic model to predict gas transport was developed using data from the bench-top experiments and validated with in vivo testing. This was a proof of concept study showing adequate oxygen transport across a parallel plate SµM-PDMS membrane when used as a membrane oxygenator. This work establishes the tools and the equipoise to develop future generations of silicon micropore membrane oxygenators. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Vanhoof, Chris; Corthouts, Valère; Tirez, Kristof
2004-04-01
To determine the heavy metal content in soil samples at contaminated locations, a static and time consuming procedure is used in most cases. Soil samples are collected and analyzed in the laboratory at high quality and high analytical costs. The demand by government and consultants for a more dynamic approach and by customers requiring performances in which analyses are performed in the field with immediate feedback of the analytical results, is growing. Especially during the follow-up of remediation projects or during the determination of the sampling strategy, field analyses are advisable. For this purpose four types of ED-XRF systems, ranging from portable up to high performance laboratory systems, have been evaluated. The evaluation criteria are based on the performance characteristics for all the ED-XRF systems such as limit of detection, accuracy and the measurement uncertainty on one hand, and also the influence of the sample pretreatment on the obtained results on the other hand. The study proved that the field portable system and the bench top system, placed in a mobile van, can be applied as field techniques, resulting in semi-quantitative analytical results. A limited homogenization of the analyzed sample significantly increases the representativeness of the soil sample. The ED-XRF systems can be differentiated by their limits of detection which are a factor of 10 to 20 higher for the portable system. The accuracy of the results and the measurement uncertainty also improved using the bench top system. Therefore, the selection criteria for applicability of both field systems are based on the required detection level and also the required accuracy of the results.
Papasouliotis, Kostas; Murphy, Kate; Dodkin, Steve; Torrance, Andy G
2002-01-01
Pleural and peritoneal effusion is a common clinical finding in feline practice. Determination of fluid albumin (ALB) and globulin (GLOB) concentrations in addition to total protein (TP) concentration can be helpful in diagnosing or ruling out certain diseases in cats, especially feline infectious peritonitis (FIP). The objective of this study was to compare effusion TP, ALB, and GLOB results obtained by a refractometer and a bench-top dry chemistry analyzer with those results obtained by a reference method. Twenty-six pleural and 14 peritoneal effusion samples were analyzed from 40 cats with various diseases. TP and ALB concentrations were determined by a reference automated wet chemistry analyzer (Kone Specific, Kone Instruments, Espoo, Finland), a bench-top dry chemistry analyzer (Vettest 8008, IDEXX Laboratories Ltd, Chalfont St Peter, UK), and a refractometer (Atago SPR-T2, Atago Co, Tokyo, Japan). GLOB, albumin to globulin (A/G) ratio, and globulins as a percentage of total proteins (GLOB%) were calculated. Results were analyzed by paired t tests, difference plots, and Deming s regression analysis. Correlation coefficients (r) for TP with Vettest versus Kone and refractometer versus Kone methods were.97 and.94, respectively. GLOB and GLOB% values were significantly higher and A/G ratios were significantly lower with Vettest versus Kone methods. Correlation coefficients for ALB, GLOB, GLOB% and A/G ratio with Vettest versus Kone methods were.86,.93,.82, and.73, respectively. Although correlation with other methods was good, the refractometer underestimated TP concentrations in 3 samples. The refractometer is an acceptable method for determination of TP concentration in feline effusions. The Vettest 8008 also is an acceptable method for the determination of TP and ALB concentrations, however, calculated A/G ratios obtained with the Vettest are unacceptable.
McCain, Stephanie L; Flatland, Bente; Schumacher, Juergen P; Clarke Iii, Elsburgh O; Fry, Michael M
2010-12-01
Advantages of handheld and small bench-top biochemical analyzers include requirements for smaller sample volume and practicality for use in the field or in practices, but little has been published on the performance of these instruments compared with standard reference methods in analysis of reptilian blood. The aim of this study was to compare reptilian blood biochemical values obtained using the Abaxis VetScan Classic bench-top analyzer and a Heska i-STAT handheld analyzer with values obtained using a Roche Hitachi 911 chemical analyzer. Reptiles, including 14 bearded dragons (Pogona vitticeps), 4 blue-tongued skinks (Tiliqua gigas), 8 Burmese star tortoises (Geochelone platynota), 10 Indian star tortoises (Geochelone elegans), 5 red-tailed boas (Boa constrictor), and 5 Northern pine snakes (Pituophis melanoleucus melanoleucus), were manually restrained, and a single blood sample was obtained and divided for analysis. Results for concentrations of albumin, bile acids, calcium, glucose, phosphates, potassium, sodium, total protein, and uric acid and activities of aspartate aminotransferase and creatine kinase obtained from the VetScan Classic and Hitachi 911 were compared. Results for concentrations of chloride, glucose, potassium, and sodium obtained from the i-STAT and Hitachi 911 were compared. Compared with results from the Hitachi 911, those from the VetScan Classic and i-STAT had variable correlations, and constant or proportional bias was found for many analytes. Bile acid data could not be evaluated because results for 44 of 45 samples fell below the lower linearity limit of the VetScan Classic. Although the 2 portable instruments might provide measurements with clinical utility, there were significant differences compared with the reference analyzer, and development of analyzer-specific reference intervals is recommended. ©2010 American Society for Veterinary Clinical Pathology.
In situ monitoring using Lab on Chip devices, with particular reference to dissolved silica.
NASA Astrophysics Data System (ADS)
Turner, G. S. C.; Loucaides, S.; Slavik, G. J.; Owsianka, D. R.; Beaton, A.; Nightingale, A.; Mowlem, M. C.
2016-02-01
In situ sensors are attractive alternatives to discrete sampling of natural waters, offering the potential for sustained long term monitoring and eliminating the need for sample handling. This can reduce sample contamination and degradation. In addition, sensors can be clustered into multi-parameter observatories and networked to provide both spatial and time series coverage. High resolution, low cost, and long term monitoring are the biggest advantages of these technologies to oceanographers. Microfluidic technology miniaturises bench-top assay systems into portable devices, known as a `lab on a chip' (LOC). The principle advantages of this technology are low power consumption, simplicity, speed, and stability without compromising on quality (accuracy, precision, selectivity, sensitivity). We have successfully demonstrated in situ sensors based on this technology for the measurement of pH, nitrate and nitrite. Dissolved silica (dSi) is an important macro-nutrient supporting a major fraction of oceanic primary production carried out by diatoms. The biogeochemical Si cycle is undergoing significant modifications due to human activities, which affects availability of dSi, and consequently primary production. Monitoring dSi concentrations is therefore critical in increasing our understanding of the biogeochemical Si cycle to predict and manage anthropogenic perturbations. The standard bench top air segmented flow technique utilising the reduction of silicomolybdic acid with spectrophotometric detection has been miniaturised into a LOC system; the target limit of detection is 1 nM, with ± 5% accuracy and 3% precision. Results from the assay optimisation are presented along with reagent shelf life to demonstrate the robustness of the chemistry. Laboratory trials of the sensor using ideal solutions and environmental samples in environmentally relevant conditions (temperature, pressure) are discussed, along with an overview of our current LOC analytical capabilities.
Tang, Siah Ying; Shridharan, Parthasarathy; Sivakumar, Manickam
2013-01-01
In the present investigation, the operating efficiency of a bench-top air-driven microfluidizer has been compared to that of a bench-top high power ultrasound horn in the production of pharmaceutical grade nanoemulsions using aspirin as a model drug. The influence of important process variables as well as the pre-homogenization and drug loading on the resultant mean droplet diameter and size distribution of emulsion droplets was studied in an oil-in-water nanoemulsion incorporated with a model drug aspirin. Results obtained show that both the emulsification methods were capable of producing very fine nanoemulsions containing aspirin with the minimum droplet size ranging from 150 to 170 nm. In case of using the microfluidizer, it has been observed that the size of the emulsion droplets obtained was almost independent of the applied microfluidization pressure (200-600 bar) and the number of passes (up to 10 passes) while the pre-homogenization and drug loading had a marginal effect in increasing the droplet size. Whereas, in the case of ultrasound emulsification, the droplet size was generally decreased with an increase in sonication amplitude (50-70%) and period of sonication but the resultant emulsion was found to be dependent on the pre-homogenization and drug loading. The STEM microscopic observations illustrated that the optimized formulations obtained using ultrasound cavitation technique are comparable to microfluidized emulsions. These comparative results demonstrated that ultrasound cavitation is a relatively energy-efficient yet promising method of pharmaceutical nanoemulsions as compared to microfluidizer although the means used to generate the nanoemulsions are different. Copyright © 2012 Elsevier B.V. All rights reserved.
Evaluation of steam penetration and sterilization of natural latex wraps.
Rossanese, Matteo; Gasson, James; Barker, Colin; Bowlt, Kelly
2014-11-01
To evaluate the efficacy of steam and ethylene oxide (EtO) sterilization of Vetrap™ bandages. Prospective experimental study. Vetrap™ bandages (n = 70; 35 as supplied by the manufacturer, 35 unwound and tightly rewound). Vetrap™ bandage rolls (n = 60) marked with a 1 cm square were inoculated with 0.1 mL Geobacillus stearothermophilus spores, packaged in a pouch together with independent sterilization indicators and assigned into 3 sub-groups for sterilizer type: dynamic air removal, gravity displacement, and bench-top pre-vacuum and further sub-divided into 2 sterilization temperatures. Vetrap™ bandages rolls (n = 10) were inoculated with 0.1 mL Bacillus atrophaeus spores in the same manner and underwent EtO sterilization. After sterilization, the 1 cm marked square was aseptically resected to the level of the cardboard tube and enriched in a flask containing 10 mL tryptic soy broth for 24 hours at 60°C for G. stearothermophilus and 37°C for B. atrophaeus. Aliquots were subsequently plated on a Petri dish of tryptic soy agar and incubated at 60°C for G. stearothermophilus and 37°C for B. atrophaeus for 24 hours. Samples were scored positive if colonies of indicator organism were present on the nutrient agar after 24 hours. Three Vetrap™ bandages yielded post-sterilization growth of G. stearothermophilus: 2 from the dynamic air removal sterilizer at 134°C for 3.5 minutes, and 1 from the bench-top pre-vacuum sterilizer at 121°C for 15 minutes. After EtO sterilization, no positive samples were detected. Steam sterilization may be incomplete for Vetrap™ bandages whereas EtO showed complete destruction of resistant bacterial spores. © Copyright 2014 by The American College of Veterinary Surgeons.
The Effect of Micrite on Velocity, Its Sensitivity to Pressure, and Dissolution of Carbonates
NASA Astrophysics Data System (ADS)
El Husseiny, A.; Vanorio, T.
2014-12-01
This study investigates the effect of micrite on the acoustic properties of well-controlled microstructures created in the laboratory to closely mimic carbonate rocks. In particular, we examine the effect of micrite content on the elastic stiffness rock, its sensitivity to pressure, and induced dissolution upon saturation with a reactive fluid. We followed Dunham's classification and fabricated the samples by mixing coarse (sand size) and very fine (micrite size) calcite grains in different ratios, with the addition of cement and then cold-compressing the mixture. The acoustic velocities were measured under bench-top conditions and as functions of confining pressure before and after the injection of a CO2aqueous solution. Our bench-top measurements indicated that micrite makes the frame of the carbonate samples stiffer. Since the sensitivity of the elastic stiffness to pressure decreases as the content of micrite increases (see figure 1), we hypothesize a stiffer pore structure (i.e., rounder pores) in micrite-richer fabrics. Furthermore, the presence of micrite makes the carbonate sample more reactive upon dissolution. The concentration of Ca+2 cations in the fluid measured at the outlet after the injection of the CO2 aqueous solution shows larger dissolution in the micrite-rich samples likely due to the higher surface area of the micrite aggregates. The content of micrite also seems to affect the evolution of stiffness as dissolution proceeds. As the content of micrite increases, the enhanced dissolution translates into a marked softening of the rock frame. We conclude that the content of micrite can play an important role in the complex rock-fluid interaction of carbonates as well as when comparing Gassmann's predictions to velocity measurements of saturated carbonates.
A miniature bidirectional telemetry system for in vivo gastric slow wave recordings.
Farajidavar, Aydin; O'Grady, Gregory; Rao, Smitha M N; Cheng, Leo K; Abell, Thomas; Chiao, J-C
2012-06-01
Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical userinter face. The front-end module conditions the analogue signals, then digitizes and loads the data into a radio for transmission. Data receipt at the backend is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35 × 35 × 27 mm3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124 h operation when utilizing a 560 mAh, 3 V battery. In vivo,slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles min−1), automated activation time detection was modestly better for the wireless system (5% versus 14% FP rate), and signal amplitudes were modestly higher via the wireless system (462 versus 3 86μV; p<0.001). This telemetric system for slow wave acquisition is reliable,power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients.0967-3334/
NASA Astrophysics Data System (ADS)
Katta, Nitesh; Mcelroy, Austin; Estrada, Arnold; Milner, Thomas E.
2017-02-01
Neurological cancer surgeries require specialized tools that enhance imaging for precise cutting and removal of tissue without damaging adjacent neurological structures. The novel combination of high-resolution fast optical coherence tomography (OCT) alongside short pulsed nanosecond thulium (Tm) lasers offers stark advantages utilizing the superior beam quality, high volumetric tissue removal rates of thulium lasers with minimal residual thermal footprint in the tissue and avoiding damage to delicate sub-surface structures (e.g., nerves and microvessels); which has not been showcased before. A bench-top system is constructed, using a 15W 1940nm nanosecond pulsed Tm fiber laser (500uJ pulse energy, 100ns pulse duration, 30kHz repetition rate) for removing tissue and a swept source laser (1310±70nm, 100kHz sweep rate) is utilized for OCT imaging, forming a combined Tm/OCT system - a smart laser knife. The OCT image-guidance informs the Tm laser for cutting/removal of targeted tissue structures. Tissue phantoms were constructed to demonstrate surgical incision with blood vessel avoidance on the surface where 2mm wide 600um deep cuts are executed around the vessel using OCT to guide the procedure. Cutting up to delicate subsurface blood vessels (2mm deep) is demonstrated while avoiding damage to their walls. A tissue removal rate of 5mm^3/sec is obtained from the bench-top system. We constructed a blow-off model to characterize Tm cut depths taking into account the absorption coefficients and beam delivery systems to compute Arrhenius damage integrals. The model is used to compare predicted tissue removal rate and residual thermal injury with experimental values in response to Tm laser-tissue modification.
Engagement of Metal Debris into a Gear Mesh
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.; Krantz, Timothy L.
2009-01-01
A series of bench top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock, and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined. INTRODUCTION In some space mechanisms the loading can be so high that there is some possibility that a gear chip might be liberated while in operation of the mechanism [1-5]. Also, due to the closely packed nature of some space mechanisms and the fact that a space grease is used for lubrication, chips that are released can then be introduced to other gear meshes within this mechanism. In this instance, it is desirable to know the consequences of a gear chip entering in between meshing gear teeth. To help provide some understanding, a series of bench-top experiments was conducted to engage chips of simulated and gear material fragments into a meshing gear pair. One purpose of the experiments was to determine the relationship of chip size to the torque required to rotate the gear set through the mesh cycle. The second purpose was to determine the condition of the gear chip material after engagement by the meshing gears, primarily to determine if the chip would break into pieces and to observe the motion of the chip as the engagement was completed. This document also presents preliminary testing done with metal debris other than chips from gears, namely steel shim stock and drill bits of various sizes and diameters.
A miniature bidirectional telemetry system for in-vivo gastric slow wave recordings
Farajidavar, Aydin; O’Grady, Gregory; Rao, Smitha M.N.; Cheng, Leo K; Abell, Thomas; Chiao, J.-C.
2012-01-01
Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical user interface. The front-end module conditions the analog signals, then digitizes and loads the data into a radio for transmission. Data receipt at the back-end is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in-vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35×35×27 mm3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124-hour operation when utilizing a 560-mAh, 3-V battery. In-vivo, slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles/min), automated activation time detection was modestly better for the wireless system (5% vs 14% false positive rate), and signal amplitudes were modestly higher via the wireless system (462 vs 386 μV; p<0.001). This telemetric system for slow wave acquisition is reliable, power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients. PMID:22635054
NASA Astrophysics Data System (ADS)
Rea, B.; Evans, D. J. A.; Benn, D. I.; Brennan, A. J.
2012-04-01
Networks of crevasse squeeze ridges (CSRs) preserved on the forelands of many surging glaciers attest to extensive full-depth crevassing. Full-depth connections have been inferred from turbid water up-welling in crevasses and the formation of concertina eskers however, it has not been clearly established if the crevasses formed from the top-down or the bottom-up. A Linear Elastic Fracture Mechanics (LEFM) approach is used to determine the likely propagation direction for Mode I crevasses on seven surging glaciers. Results indicate that, the high extensional surface strain rates are insufficient to promote top-down full-depth crevasses but have sufficient magnitude to penetrate to depths of 4-12 m, explaining the extensive surface breakup accompanying glacier surges. Top-down, full-depth crevassing is only possible when water depth approaches 97% of the crevasse depth. However, the provision of sufficient meltwater is problematic due to the aforementioned extensive shallow surface crevassing. Full-depth, bottom-up crevassing can occur provided basal water pressures are in excess of 80-90% of flotation which is the default for surging and on occasion water pressures may even become artesian. Therefore CSRs, found across many surging glacier forelands and ice margins most likely result from the infilling of basal crevasses formed, for the most part, by bottom-up hydrofracturing. Despite the importance of crevassing for meltwater routing and calving dynamics physically testing numerical crevassing models remains problematic due to technological limitations, changing stress regimes and difficulties associated with working in crevasse zones on glaciers. Mapping of CSR spacing and matching to surface crevasse patterns can facilitate quantitative comparison between the LEFM model and observed basal crevasses provided ice dynamics are known. However, assessing full-depth top-down crevasse propagation is much harder to monitor in the field and no geomorphological record is preserved. An alternative approach is provided by geotechnical centrifuge modelling. By testing scaled models in an enhanced 'gravity' field real-world (prototype) stress conditions can be reproduced which is crucial for problems governed by self-weight stresses, of which glacier crevassing is one. Scaling relationships have been established for stress intensity factors - KI which are key to determining crevasse penetration such that KIp = √N KIm (p = prototype and m = model). Operating specifications of the University of Dundee geotechnical centrifuge (100g) will allow the testing of scaled models equivalent to prototype glaciers of 50 m thickness in order to provide a physical test of the LEFM top-down crevassing model.
Han, Yu Long; Wang, Wenqi; Hu, Jie; Huang, Guoyou; Wang, Shuqi; Lee, Won Gu; Lu, Tian Jian; Xu, Feng
2013-12-21
We presented a benchtop technique that can fabricate reconfigurable, three-dimensional (3D) microfluidic devices made from a soft paper-polymer composite. This fabrication approach can produce microchannels at a minimal width of 100 μm and can be used to prototype 3D microfluidic devices by simple bending and stretching. The entire fabrication process can be finished in 2 hours on a laboratory bench without the need for special equipment involved in lithography. Various functional microfluidic devices (e.g., droplet generator and reconfigurable electronic circuit) were prepared using this paper-polymer hybrid microfluidic system. The developed method can be applied in a wide range of standard applications and emerging technologies such as liquid-phase electronics.
Patterson, Jeffrey M.; Oppenheimer, Nicole E.; Feser, Erin H.
2015-01-01
Training the bench press exercise on a traditional flat bench does not induce a level of instability as seen in sport movements and activities of daily living. Twenty participants were recruited to test two forms of instability: using one dumbbell rather than two and lifting on the COR bench compared to a flat bench. Electromyography (EMG) amplitudes of the pectoralis major, middle trapezius, external oblique, and internal oblique were recorded and compared. Differences in range of motion (ROM) were evaluated by measuring an angular representation of the shoulder complex. Four separate conditions of unilateral bench press were tested while lifting on a: flat bench with one dumbbell, flat bench with two dumbbells, COR Bench with one dumbbell, and COR Bench with two dumbbells. The results imply that there are no differences in EMG amplitude or ROM between the COR bench and traditional bench. However, greater ROM was found to be utilized in the single dumbbell condition, both in the COR bench and the flat bench. PMID:26528421
Prototype pushing robot for emplacing vitrified waste canisters into horizontal disposal drifts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Londe, L.; Seidler, W.K.; Bosgiraud, J.M.
2007-07-01
Within the French Underground Disposal concept, as described in ANDRA's (Agence Nationale pour la Gestion des Dechets Radioactifs) Dossier 2005, the Pushing Robot is an application envisaged for the emplacement (and the potential retrieval) of 'Vitrified waste packages', also called 'C type packages'. ANDRA has developed a Prototype Pushing Robot within the framework of the ESDRED Project (Engineering Studies and Demonstration of Repository Design) which is co-funded by the European Commission as part of the sixth EURATOM Research and Training Framework Programme (FP6) on nuclear energy (2002 - 2006). The Rationale of the Pushing Robot technology comes from various considerations,more » including the need for (1) a simple and robust system, capable of moving (and potentially retrieving) on up to 40 metres (m), a 2 tonne C type package (mounted on ceramic sliding runners) inside the carbon steel sleeve constituting the liner (and rock support) of a horizontal disposal cell, (2) small annular clearances between the package and the liner, (3) compactness of the device to be transferred from surface to underground, jointly with the package, inside a shielding cask, and (4) remote controlled operations for the sake of radioprotection. The initial design, based on gripping supports, has been replaced by a 'technical variant' based on inflatable toric jacks. It was then possible, using a test bench, to check that the Pushing Robot worked properly. Steps as high as 7 mm were successfully cleared by a dummy package pushed by the Prototype.. Based on the lessons learned by ANDRA's regarding the Prototype Pushing Robot, a new Scope of Work is being written for the Contract concerning an Industrial Scale Demonstrator. The Industrial Scale Demonstration should be completed by the end of the second Quarter of 2008. (authors)« less
Resistively-Heated Microlith-based Adsorber for Carbon Dioxide and Trace Contaminant Removal
NASA Technical Reports Server (NTRS)
Roychoudhury, S.; Walsh, D.; Perry, J.
2005-01-01
An integrated sorber-based Trace Contaminant Control System (TCCS) and Carbon Dioxide Removal Assembly (CDRA) prototype was designed, fabricated and tested. It corresponds to a 7-person load. Performance over several adsorption/regeneration cycles was examined. Vacuum regenerations at effective time/temperature conditions, and estimated power requirements were experimentally verified for the combined CO2/trace contaminant removal prototype. The current paper details the design and performance of this prototype during initial testing at CO2 and trace contaminant concentrations in the existing CDRA, downstream of the drier. Additional long-term performance characterization is planned at NASA. Potential system design options permitting associated weight, volume savings and logistic benefits, especially as relevant for long-duration space flight, are reviewed. The technology consisted of a sorption bed with sorbent- coated metal meshes, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI). By contrast the current CO2 removal system on the International Space Station employs pellet beds. Preliminary bench scale performance data (without direct resistive heating) for simultaneous CO2 and trace contaminant removal was reviewed in SAE 2004-01-2442. In the prototype, the meshes were directly electrically heated for rapid response and accurate temperature control. This allowed regeneration via resistive heating with the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. A novel flow arrangement, for removing both CO2 and trace contaminants within the same bed, was demonstrated. Thus, the need for a separate trace contaminant unit was eliminated resulting in an opportunity for significant weight savings. Unlike the current disposable charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration.
Rapid Protein Separations in Microfluidic Devices
NASA Technical Reports Server (NTRS)
Fan, Z. H.; Das, Champak; Xia, Zheng; Stoyanov, Alexander V.; Fredrickson, Carl K.
2004-01-01
This paper describes fabrication of glass and plastic microfluidic devices for protein separations. Although the long-term goal is to develop a microfluidic device for two-dimensional gel electrophoresis, this paper focuses on the first dimension-isoelectric focusing (IEF). A laser-induced fluorescence (LIF) imaging system has been built for imaging an entire channel in an IEF device. The whole-channel imaging eliminates the need to migrate focused protein bands, which is required if a single-point detector is used. Using the devices and the imaging system, we are able to perform IEF separations of proteins within minutes rather than hours in traditional bench-top instruments.
Biochips Containing Arrays of Carbon-Nanotube Electrodes
NASA Technical Reports Server (NTRS)
Li, Jun; Meyyappan, M.; Koehne, Jessica; Cassell, Alan; Chen, Hua
2008-01-01
Biochips containing arrays of nanoelectrodes based on multiwalled carbon nanotubes (MWCNTs) are being developed as means of ultrasensitive electrochemical detection of specific deoxyribonucleic acid (DNA) and messenger ribonucleic acid (mRNA) biomarkers for purposes of medical diagnosis and bioenvironmental monitoring. In mass production, these biochips could be relatively inexpensive (hence, disposable). These biochips would be integrated with computer-controlled microfluidic and microelectronic devices in automated hand-held and bench-top instruments that could be used to perform rapid in vitro genetic analyses with simplified preparation of samples. Carbon nanotubes are attractive for use as nanoelectrodes for detection of biomolecules because of their nanoscale dimensions and their chemical properties.
The Nano-Patch-Clamp Array: Microfabricated Glass Chips for High-Throughput Electrophysiology
NASA Astrophysics Data System (ADS)
Fertig, Niels
2003-03-01
Electrophysiology (i.e. patch clamping) remains the gold standard for pharmacological testing of putative ion channel active drugs (ICADs), but suffers from low throughput. A new ion channel screening technology based on microfabricated glass chip devices will be presented. The glass chips contain very fine apertures, which are used for whole-cell voltage clamp recordings as well as single channel recordings from mammalian cell lines. Chips containing multiple patch clamp wells will be used in a first bench-top device, which will allow perfusion and electrical readout of each well. This scalable technology will allow for automated, rapid and parallel screening on ion channel drug targets.
Testing of Composite Fan Vanes With Erosion-Resistant Coating Accelerated
NASA Technical Reports Server (NTRS)
Bowman, Cheryl L.; Sutter, James K.; Otten, Kim D.; Samorezov, Sergey; Perusek, Gail P.
2004-01-01
The high-cycle fatigue of composite stator vanes provided an accelerated life-state prior to insertion in a test stand engine. The accelerated testing was performed in the Structural Dynamics Laboratory at the NASA Glenn Research Center under the guidance of Structural Mechanics and Dynamics Branch personnel. Previous research on fixturing and test procedures developed at Glenn determined that engine vibratory conditions could be simulated for polymer matrix composite vanes by using the excitation of a combined slip table and electrodynamic shaker in Glenn's Structural Dynamics Laboratory. Bench-top testing gave researchers the confidence to test the coated vanes in a full-scale engine test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hong; Kong, Vic; Ren, Lei
2016-01-15
Purpose: A preobject grid can reduce and correct scatter in cone beam computed tomography (CBCT). However, half of the signal in each projection is blocked by the grid. A synchronized moving grid (SMOG) has been proposed to acquire two complimentary projections at each gantry position and merge them into one complete projection. That approach, however, suffers from increased scanning time and the technical difficulty of accurately merging the two projections per gantry angle. Herein, the authors present a new SMOG approach which acquires a single projection per gantry angle, with complimentary grid patterns for any two adjacent projections, and usemore » an interprojection sensor fusion (IPSF) technique to estimate the blocked signal in each projection. The method may have the additional benefit of reduced imaging dose due to the grid blocking half of the incident radiation. Methods: The IPSF considers multiple paired observations from two adjacent gantry angles as approximations of the blocked signal and uses a weighted least square regression of these observations to finally determine the blocked signal. The method was first tested with a simulated SMOG on a head phantom. The signal to noise ratio (SNR), which represents the difference of the recovered CBCT image to the original image without the SMOG, was used to evaluate the ability of the IPSF in recovering the missing signal. The IPSF approach was then tested using a Catphan phantom on a prototype SMOG assembly installed in a bench top CBCT system. Results: In the simulated SMOG experiment, the SNRs were increased from 15.1 and 12.7 dB to 35.6 and 28.9 dB comparing with a conventional interpolation method (inpainting method) for a projection and the reconstructed 3D image, respectively, suggesting that IPSF successfully recovered most of blocked signal. In the prototype SMOG experiment, the authors have successfully reconstructed a CBCT image using the IPSF-SMOG approach. The detailed geometric features in the Catphan phantom were mostly recovered according to visual evaluation. The scatter related artifacts, such as cupping artifacts, were almost completely removed. Conclusions: The IPSF-SMOG is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.« less
NASA Technical Reports Server (NTRS)
Boyle, Robert M.; Mitchell, Kathryn; Allton, Charles; Ju, Hsing
2012-01-01
The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a space suit while the space suit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a space suit prototype on the second generation MMSEV cabin, and testing is planned using the pressure differentials of the spacecraft. Pressurized testing will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, a suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents the design of a human rated second generation suitport, the design of a suit capable of supporting pressurized human donning through a suitport, ambient pressure testing of the suit with the suitport, and modifications to the JSC human rated chamber B to accept a suitport. Design challenges and solutions, as well as compromises required to develop the system, are presented. Initial human testing results are presented.
Top tether effectiveness during side impacts.
Majstorovic, Jordan; Bing, Julie; Dahle, Eric; Bolte, John; Kang, Yun-Seok
2018-02-28
Few studies have looked at the effectiveness of the top tether during side impacts. In these studies, limited anthropomorphic test device (ATD) data were collected and/or few side impact scenarios were observed. The goal of this study was to further understand the effects of the top tether on ATD responses and child restraint system (CRS) kinematics during various side impact conditions. A series of high-speed near-side and far-side sled tests were performed using the FMVSS213 side impact sled buck and Q3s ATD. Tests were performed at both 10° and 30° impacts with respect to the pure lateral direction. Two child restraints, CRS A and CRS B, were attached to the bench using flexible lower anchors. Each test scenario was performed with the presence and absence of a top tether. Instrumentation recorded Q3s responses and CRS kinematics, and the identical test scenarios with and without a top tether attachment were compared. For the far-side lateral (10°) and oblique (30°) impacts, top tether attachment increased resultant head accelerations by 8-38% and head injury criterion (HIC 15 ) values by 20-140%. However, the top tether was effective in reducing lateral head excursion by 5-25%. For near-side impacts, the top tether resulted in less than 10% increases in both resultant head acceleration and HIC 15 in the lateral impact direction. For near-side oblique impacts, the top tether increased HIC 15 by 17.3% for CRS A and decreased it by 19.5% for CRS B. However, the injury values determined from both impact conditions were below current injury assessment reference values (IARVs). Additionally, the top tether proved beneficial in preventing forward and lateral CRS rotations. The results show that the effects of the top tether on Q3s responses were dependent on impact type, impact angle, and CRS. Tether attachments that increased head accelerations and HIC 15 values were generally counterbalanced by a reduction in head excursion and CRS rotation compared to nontethered scenarios.
Finding future high-cost cases: comparing prior cost versus diagnosis-based methods.
Ash, A S; Zhao, Y; Ellis, R P; Schlein Kramer, M
2001-01-01
OBJECTIVE: To examine the value of two kinds of patient-level dat a (cost and diagnoses) for identifying a very small subgroup of a general population with high future costs that may be mitigated with medical management. DATA SOURCES: The study used the MEDSTAT Market Scan (R) Research Database, consisting of inpatient and ambulatory health care encounter records for individuals covered by employee- sponsored benefit plans during 1997 and 1998. STUDY DESIGN: Prior cost and a diagnostic cost group (DCG) risk model were each used with 1997 data to identify 0.5-percent-sized "top groups" of people most likely to be expensive in 1998. We compared the distributions of people, cost, and diseases commonly targeted for disease management for people in the two top groups and, as a bench mark, in the full population. PRINCIPAL FINDINGS: the prior cost- and DCG-identified top groups overlapped by only 38 percent. Each top group consisted of people with high year-two costs and high rates of diabetes, heart failure, major lung disease, and depression. The DCG top group identified people who are both somewhat more expensive ($27,292 vs. $25,981) and more likely ( 49.4 percent vs. 43.8 percent ) th an the prior-cost top group to have at least one of the diseases commonly targeted for disease management. The overlap group average cost was $46,219. CONCLUSIONS: Diagnosis-based risk models are at least as powerful as prior cost for identifying people who will be expensive. Combined cost and diagnostic data are even more powerful and more operation ally useful, especially because the diagnostic information identifies the medical problems that may be managed to achieve better out comes and lower costs. PMID:16148969
NASA Astrophysics Data System (ADS)
Mamidala, Rajinikanth; Majumdar, Papiya; Jha, Kunal Kumar; Bathula, Chandramohan; Agarwal, Rahul; Chary, M. Thirumala; Mazumdar, H. K.; Munshi, Parthapratim; Sen, Subhabrata
2016-05-01
A library of arylidenefuropyridinediones was discovered as potent inhibitors of Leishmania donovani Topoisomerase 1 (LdTop1) where the active molecules displayed considerable inhibition with single digit micromolar EC50 values. This molecular library was designed via intuitive scaffold hopping and bioisosteric modification of known topoisomerase 1 inhibitors such as camptothecin, edotecarin and etc. The design was rationalized by molecular docking analysis of the compound prototype with human topoisomerase 1 (HTop1) and Leishmania donovani topoisomerase 1(LdTop1). The most active compound 4 displayed no cytotoxicity against normal mammalian COS7 cell line (~100 fold less inhibition at the EC50). Similar to camptothecin, 4 interacted with free LdTop1 as observed in the preincubation DNA relaxation inhibition experiment. It also displayed anti-protozoal activity against Leishmania donovani promastigote. Crystal structure investigation of 4 and its molecular modelling with LdTop1 revealed putative binding sites in the enzyme that could be harnessed to generate molecules with better potency.
Topoisomerase VI senses and exploits both DNA crossings and bends to facilitate strand passage
Wendorff, Timothy J
2018-01-01
Type II topoisomerases manage DNA supercoiling and aid chromosome segregation using a complex, ATP-dependent duplex strand passage mechanism. Type IIB topoisomerases and their homologs support both archaeal/plant viability and meiotic recombination. Topo VI, a prototypical type IIB topoisomerase, comprises two Top6A and two Top6B protomers; how these subunits cooperate to engage two DNA segments and link ATP turnover to DNA transport is poorly understood. Using multiple biochemical approaches, we show that Top6B, which harbors the ATPase activity of topo VI, recognizes and exploits the DNA crossings present in supercoiled DNA to stimulate subunit dimerization by ATP. Top6B self-association in turn induces extensive DNA bending, which is needed to support duplex cleavage by Top6A. Our observations explain how topo VI tightly coordinates DNA crossover recognition and ATP binding with strand scission, providing useful insights into the operation of type IIB topoisomerases and related meiotic recombination and GHKL ATPase machineries. PMID:29595473
Testing light concentrators prototypes for the Cherenkov Telescope Array
NASA Astrophysics Data System (ADS)
Hénault, François; Petrucci, Pierre-Olivier; Jocou, Laurent; Arezki, Brahim; Magnard, Yves; Khélifi, Bruno; Manigot, Pascal; Olive, Jean-François; Jean, Pierre; Punch, Michael
2017-09-01
With more than 30 Medium-Size Telescopes (MST) located in both North and South hemispheres, the Cherenkov Telescope Array (CTA) shall be the largest cosmic gamma ray detector ever built. Each MST focal plane consists in an array of some 1800 photomultipliers equipped with their own light concentrating optics in order to maximizing the amount of Cherenkov radiation collected by the telescope and to block stray light originating from ground environment. Within the CTA Consortium, the Institut de Planétologie et d'Astrophysique de Grenoble (IPAG) is in charge of designing, subcontracting the realization to industry, and testing the MST light concentrators. Two different optical solutions were pre-selected, respectively based on CPCs (Winston cones) and non-imaging concentrating lenses. Prototypes were manufactured by different industrial companies and tested in our laboratory on a test bench specifically built for the project. After shortly describing both optical designs, this communication is essentially focused at experimental results. Each type of concentrator has been submitted to extensive performance measurements, including radiometric efficiency at different wavelengths, rejection curves, and qualitative shape error test. The final selected concentrator is the CPC, although non-imaging lenses exhibit interesting properties in terms of radiometric performance.
Opto-mechanical design of an image slicer for the GRIS spectrograph at GREGOR
NASA Astrophysics Data System (ADS)
Vega Reyes, N.; Esteves, M. A.; Sánchez-Capuchino, J.; Salaun, Y.; López, R. L.; Gracia, F.; Estrada Herrera, P.; Grivel, C.; Vaz Cedillo, J. J.; Collados, M.
2016-07-01
An image slicer has been proposed for the Integral Field Spectrograph [1] of the 4-m European Solar Telescope (EST) [2] The image slicer for EST is called MuSICa (Multi-Slit Image slicer based on collimator-Camera) [3] and it is a telecentric system with diffraction limited optical quality offering the possibility to obtain high resolution Integral Field Solar Spectroscopy or Spectro-polarimetry by coupling a polarimeter after the generated slit (or slits). Considering the technical complexity of the proposed Integral Field Unit (IFU), a prototype has been designed for the GRIS spectrograph at GREGOR telescope at Teide Observatory (Tenerife), composed by the optical elements of the image slicer itself, a scanning system (to cover a larger field of view with sequential adjacent measurements) and an appropriate re-imaging system. All these subsystems are placed in a bench, specially designed to facilitate their alignment, integration and verification, and their easy installation in front of the spectrograph. This communication describes the opto-mechanical solution adopted to upgrade GRIS while ensuring repeatability between the observational modes, IFU and long-slit. Results from several tests which have been performed to validate the opto-mechanical prototypes are also presented.
40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)
Code of Federal Regulations, 2014 CFR
2014-07-01
... VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging bench with an...
The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance
Saeterbakken, Atle Hole; Mo, Dag-André; Scott, Suzanne; Andersen, Vidar
2017-01-01
Abstract The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-significant differences in activation were observed between the three bench positions with the exception of 58.5-62.6% lower triceps brachii activation, but 48.3-68.7% greater biceps brachii activation in the inclined bench compared with the flat and declined bench position. Comparing the three grip widths, non-significant differences in activations were observed, with the exception of 25.9-30.5% lower EMG activity in the biceps brachii using a narrow grip, compared to the medium and wide grip conditions. The 6-RM loads were 5.8-11.1% greater using a medium and wide grip compared to narrow grip width and 18.5-21.5% lower in the inclined bench position compared with flat and declined. Comparing the EMG activity during the competition bench press style with either the inclined and declined bench position (wide grip) or using a narrow and medium grip (flat bench), only resulted in different EMG activity in the biceps- and triceps brachii. The 6RM loads varied with each bench press variation and we recommend the use of a wide grip on a flat bench during high load hypertrophy training to bench press athletes. PMID:28713459
The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance.
Saeterbakken, Atle Hole; Mo, Dag-André; Scott, Suzanne; Andersen, Vidar
2017-06-01
The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-significant differences in activation were observed between the three bench positions with the exception of 58.5-62.6% lower triceps brachii activation, but 48.3-68.7% greater biceps brachii activation in the inclined bench compared with the flat and declined bench position. Comparing the three grip widths, non-significant differences in activations were observed, with the exception of 25.9-30.5% lower EMG activity in the biceps brachii using a narrow grip, compared to the medium and wide grip conditions. The 6-RM loads were 5.8-11.1% greater using a medium and wide grip compared to narrow grip width and 18.5-21.5% lower in the inclined bench position compared with flat and declined. Comparing the EMG activity during the competition bench press style with either the inclined and declined bench position (wide grip) or using a narrow and medium grip (flat bench), only resulted in different EMG activity in the biceps- and triceps brachii. The 6RM loads varied with each bench press variation and we recommend the use of a wide grip on a flat bench during high load hypertrophy training to bench press athletes.
Hypertrophic scars and keloids in surgery: current concepts.
Song, Colin
2014-09-01
Hypertrophic scars and keloids remain a challenge in surgery. We appreciate that our understanding of the process at cellular and molecular level, profound as it is, when it comes to the clinical evidence much is left to be desired. Although the bench to bedside conundrum remains, the science of translational research calls for an even higher level of cooperation between the scientist and the clinician for the impetus to succeed.The clinicians alerted us to the possible theories in the pathogenesis of keloid formation, inter alia, the ischemia theory, mast cell theory, immune theory, transforming growth factor β interaction, mechanical theory, and the melanocyte stimulating hormone theory. All of the above presupposed a stimulus that would result in an uncontrolled upregulation of collagen and extracellular matrix expression in the pathogenesis of the keloid. This bedside to bench initiative, as in true science, realized more ponderables than possibilities.By the same token, research into the epidermal-mesenchymal signaling, molecular biology, genomics, and stem cell research holds much promise in the bench top arena. To assess efficacy, many scar assessment scores exist in the literature. The clinical measurement of scar maturity can aid in determining end points for therapeutics. Tissue oxygen tension and color assessment of scars by standardized photography proved to be useful.In surgery, the use of dermal substitutes holds some promise as we surmise that quality scars that arise from dermal elements, molecular and enzyme behavior, and balance. Although a systematic review shows some benefit for earlier closure and healing of wounds, no such review exists at this point in time for the use of dermal substitutes in scars.Adipose-derived stem cell, as it pertains to scars, will hopefully realize the potential of skin regeneration rather than by repair in which we are familiar with as well as the undesirable scarring as a result of healing through the inflammatory response.Translational research will bear the fruit of coordinating bench to bedside and vice versa in the interest of progress into the field of regenerative healing that will benefit the patient who otherwise suffers the myriad of scar complications.
Assessment and monitoring of ballistic and maximal upper-body strength qualities in athletes.
Young, Kieran P; Haff, G Gregory; Newton, Robert U; Gabbett, Tim J; Sheppard, Jeremy M
2015-03-01
To evaluate whether the dynamic strength index (DSI: ballistic peak force/isometric peak force) could be effectively used to guide specific training interventions and detect training-induced changes in maximal and ballistic strength. Twenty-four elite male athletes were assessed in the isometric bench press and a 45% 1-repetition-maximum (1RM) ballistic bench throw using a force plate and linear position transducer. The DSI was calculated using the peak force values obtained during the ballistic bench throw and isometric bench press. Athletes were then allocated into 2 groups as matched pairs based on their DSI and strength in the 1RM bench press. Over the 5 wk of training, athletes performed either high-load (80-100% 1RM) bench press or moderate-load (40-55% 1RM) ballistic bench throws. The DSI was sensitive to disparate training methods, with the bench-press group increasing isometric bench-press peak force (P=.035, 91% likely), and the ballistic-bench-throw group increasing bench-throw peak force to a greater extent (P≤.001, 83% likely). A significant increase (P≤.001, 93% likely) in the DSI was observed for both groups. The DSI can be used to guide specific training interventions and can detect training-induced changes in isometric bench-press and ballistic bench-throw peak force over periods as short as 5 wk.
Millimeter wave experiment for ATS-F
NASA Technical Reports Server (NTRS)
Green, J. S.; Parisky, R. N.; Shapiro, S. S.
1973-01-01
A detailed description of spaceborne equipment is provided. The equipment consists of two transmitters radiating signals at 20 and 30 GHz from either U.S. coverage horn antennas or a narrow beam parabolic antenna. Three modes of operation are provided: a continuous wave mode, a multitone mode in which nine spectral lines having 180 MHz separation and spaced symmetrically about each carrier, and a communications mode in which communications signals from the main spacecraft transponder are modulated on the two carriers. Detailed performance attained in the flight/prototype model of the equipment is presented both under laboratory conditions and under environmental extremes. Provisions made for ensuring reliability in space operation are described. Also described the bench test equipment developed for use with the experiment, and a summary of the new technology is included.
NASA Astrophysics Data System (ADS)
Meng, Fei; Shi, Peng; Karimi, Hamid Reza; Zhang, Hui
2016-02-01
The main objective of this paper is to investigate the sensitivity analysis and optimal design of a proportional solenoid valve (PSV) operated pressure reducing valve (PRV) for heavy-duty automatic transmission clutch actuators. The nonlinear electro-hydraulic valve model is developed based on fluid dynamics. In order to implement the sensitivity analysis and optimization for the PRV, the PSV model is validated by comparing the results with data obtained from a real test-bench. The sensitivity of the PSV pressure response with regard to the structural parameters is investigated by using Sobol's method. Finally, simulations and experimental investigations are performed on the optimized prototype and the results reveal that the dynamical characteristics of the valve have been improved in comparison with the original valve.
First year in operating a mechanical detrasher system at a sugarcane factory in Louisiana
USDA-ARS?s Scientific Manuscript database
Over the past 2 years, a new prototype mechanical detrasher system was built at a Louisiana sugarcane factory by American Biocarbon LLC. It was built to remove sugarcane trash (top stalks and leaves) before processing, and for the manufacture and sale of value-added-products from the removed trash,...
GRASP - A Prototype Interactive Graphic Sawing Program - (Forest Products Journal)
Luis G. Occeña; Daniel L. Schmoldt
1996-01-01
A versatile microcomputer-based interactive graphics sawing program has been developed as a tool for modeling various hardwood processes, from bucking and topping to log sawing, lumber edging, secondary processing, and even veneering. The microcomputer platform makes the tool affordable and accessible. A solid modeling basis provides the tool with a sound geometrical...
GRASP - A Prototype Interactive Graphic Sawing Program - (MU-IE Technical Report)
Luis G. Occeña; Daniel L. Schmoldt
1995-01-01
A versatile microcomputer-based interactive graphics program has been developed as a tool for modeling various hardwood processes, from bucking and topping to log sawing, lumber edging, secondary processing, even veneering. The microcomputer platform makes the tool affordable and accessible.A solid modeling basis provides the tool with a sound geometrical and...
USDA-ARS?s Scientific Manuscript database
Evapotranspiration estimates for scheduling irrigation must be field specific and real time. Weather station networks provide daily reference ET values, but users need to select crop coefficients for their particular crop and field. A prototype system has been developed that combines satellite image...
Watanabe, Toru; Mashiko, Takuma; Maftukhah, Rizki; Kaku, Nobuo; Pham, Dong Duy; Ito, Hiroaki
2017-02-01
This study aims at improving the performance of the cultivating system of rice for animal feed with circulated irrigation of treated municipal wastewater by applying a larger amount of wastewater, as well as adding a microbial fuel cell (MFC) to the system. The results of bench-scale experiments indicate that this modification has increased the rice yield, achieving the target for the rice cultivar used in the experiment. In addition, an assessment of protein content of the harvested rice showed that the value of the rice as animal fodder has improved. Compared with normal one-way irrigation, circulated irrigation significantly enhanced the plant growth and rice production. The direction of the irrigation (bottom-to-top or top-to-bottom) in the soil layer had no significant effect. This modified system demonstrated >96% for nitrogen removal from the treated wastewater used for the irrigation, with approximately 40% of the nitrogen being used for rice plant growth. The MFC installed in the system facilitated power generation comparable with that reported for normal paddy fields. The power generation appeared to be enhanced by bottom-to-top irrigation, which could provide organic-rich treated wastewater directly to the bacterial community living on the anode of the MFC set in the soil layer.
SHERPA Electromechanical Test Bed
NASA Technical Reports Server (NTRS)
Wason, John D.
2005-01-01
SHERPA (Strap-on High-altitude Entry Reconnaissance and Precision Aeromaneuver system) is a concept for low-cost-high-accuracy Martian reentry guidance for small scout-class missions with a capsule diameter of approximately 1 meter. This system uses moving masses to change the center of gravity of the capsule in order to control the lift generated by the controlled imbalance. This project involved designing a small proof-of-concept demonstration system that can be used to test the concept through bench-top testing, hardware-in-the-loop testing, and eventually through a drop test from a helicopter. This project has focused on the Mechatronic design aspects of the system including the mechanical, electrical, computer, and low-level control of the concept demonstration system.
Genome Editing of Erythroid Cell Culture Model Systems.
Yik, Jinfen J; Crossley, Merlin; Quinlan, Kate G R
2018-01-01
Genome editing to introduce specific mutations or to knock out genes in model cell systems has become an efficient platform for research in the fields of molecular biology, genetics, and cell biology. With recent rapid improvements in genome editing techniques, bench-top manipulation of the genome in cell culture has become progressively easier. The application of this knowledge to erythroid cell culture systems now allows the rapid analysis of the downstream effects of virtually any engineered gene disruption or modification in cell systems. Here, we describe a CRISPR/Cas9-based approach to making genomic modifications in erythroid lineage cells which we have successfully used in both murine (MEL) and human (K562) erythroleukaemia immortalized cell lines.
NASA Astrophysics Data System (ADS)
Asztalos, Stephen J.; Hennig, Wolfgang; Warburton, William K.
2016-01-01
Pulse shape discrimination applied to certain fast scintillators is usually performed offline. In sufficiently high-event rate environments data transfer and storage become problematic, which suggests a different analysis approach. In response, we have implemented a general purpose pulse shape analysis algorithm in the XIA Pixie-500 and Pixie-500 Express digital spectrometers. In this implementation waveforms are processed in real time, reducing the pulse characteristics to a few pulse shape analysis parameters and eliminating time-consuming waveform transfer and storage. We discuss implementation of these features, their advantages, necessary trade-offs and performance. Measurements from bench top and experimental setups using fast scintillators and XIA processors are presented.
Soft Robotic Grippers for Biological Sampling on Deep Reefs.
Galloway, Kevin C; Becker, Kaitlyn P; Phillips, Brennan; Kirby, Jordan; Licht, Stephen; Tchernov, Dan; Wood, Robert J; Gruber, David F
2016-03-01
This article presents the development of an underwater gripper that utilizes soft robotics technology to delicately manipulate and sample fragile species on the deep reef. Existing solutions for deep sea robotic manipulation have historically been driven by the oil industry, resulting in destructive interactions with undersea life. Soft material robotics relies on compliant materials that are inherently impedance matched to natural environments and to soft or fragile organisms. We demonstrate design principles for soft robot end effectors, bench-top characterization of their grasping performance, and conclude by describing in situ testing at mesophotic depths. The result is the first use of soft robotics in the deep sea for the nondestructive sampling of benthic fauna.
Towards Real Time Diagnostics of Hybrid Welding Laser/GMAW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Timothy Mcjunkin; Dennis C. Kunerth; Corrie Nichol
2013-07-01
Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defectsmore » or precursors to defects and correct when possible during the weld process.« less
Towards real time diagnostics of Hybrid Welding Laser/GMAW
DOE Office of Scientific and Technical Information (OSTI.GOV)
McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I.
2014-02-18
Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defectsmore » or precursors to defects and correct when possible during the weld process.« less
Towards real time diagnostics of Hybrid Welding Laser/GMAW
NASA Astrophysics Data System (ADS)
McJunkin, T. R.; Kunerth, D. C.; Nichol, C. I.; Todorov, E.; Levesque, S.
2014-02-01
Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.
High performance bilateral telerobot control.
Kline-Schoder, Robert; Finger, William; Hogan, Neville
2002-01-01
Telerobotic systems are used when the environment that requires manipulation is not easily accessible to humans, as in space, remote, hazardous, or microscopic applications or to extend the capabilities of an operator by scaling motions and forces. The Creare control algorithm and software is an enabling technology that makes possible guaranteed stability and high performance for force-feedback telerobots. We have developed the necessary theory, structure, and software design required to implement high performance telerobot systems with time delay. This includes controllers for the master and slave manipulators, the manipulator servo levels, the communication link, and impedance shaping modules. We verified the performance using both bench top hardware as well as a commercial microsurgery system.
Microfluidic chip-based technologies: emerging platforms for cancer diagnosis
2013-01-01
The development of early and personalized diagnostic protocols is considered the most promising avenue to decrease mortality from cancer and improve outcome. The emerging microfluidic-based analyzing platforms hold high promises to fulfill high-throughput and high-precision screening with reduced equipment cost and low analysis time, as compared to traditional bulky counterparts in bench-top laboratories. This article overviewed the potential applications of microfluidic technologies for detection and monitoring of cancer through nucleic acid and protein biomarker analysis. The implications of the technologies in cancer cytology that can provide functional personalized diagnosis were highlighted. Finally, the future niches for using microfluidic-based systems in tumor screening were briefly discussed. PMID:24070124
Particle Substructure. A Common Theme of Discovery in this Century
DOE R&D Accomplishments Database
Panofsky, W. K. H.
1984-02-01
Some example of modern developments in particle physics are given which demonstrate that the fundamental rules of quantum mechanics, applied to all forces in nature as they became understood, have retained their validity. The well-established laws of electricity and magnetism, reformulated in terms of quantum mechanics, have exhibited a truly remarkable numerical agreement between theory and experiment over an enormous range of observation. As experimental techniques have grown from the top of a laboratory bench to the large accelerators of today, the basic components of experimentation have changed vastly in scale but only little in basic function. More important, the motivation of those engaged in this type of experimentation has hardly changed at all.
Soft Robotic Grippers for Biological Sampling on Deep Reefs
Galloway, Kevin C.; Becker, Kaitlyn P.; Phillips, Brennan; Kirby, Jordan; Licht, Stephen; Tchernov, Dan; Gruber, David F.
2016-01-01
Abstract This article presents the development of an underwater gripper that utilizes soft robotics technology to delicately manipulate and sample fragile species on the deep reef. Existing solutions for deep sea robotic manipulation have historically been driven by the oil industry, resulting in destructive interactions with undersea life. Soft material robotics relies on compliant materials that are inherently impedance matched to natural environments and to soft or fragile organisms. We demonstrate design principles for soft robot end effectors, bench-top characterization of their grasping performance, and conclude by describing in situ testing at mesophotic depths. The result is the first use of soft robotics in the deep sea for the nondestructive sampling of benthic fauna. PMID:27625917
40 CFR Appendix Viii to Part 86 - Aging Bench Equipment and Procedures
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Aging Bench Equipment and Procedures.... 86, App. VIII Appendix VIII to Part 86—Aging Bench Equipment and Procedures This appendix provides specifications for standard aging bench equipment and aging procedures which may be used to conduct bench aging...
40 CFR Appendix Viii to Part 86 - Aging Bench Equipment and Procedures
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Aging Bench Equipment and Procedures.... VIII Appendix VIII to Part 86—Aging Bench Equipment and Procedures This appendix provides specifications for standard aging bench equipment and aging procedures which may be used to conduct bench aging...
40 CFR Appendix Viii to Part 86 - Aging Bench Equipment and Procedures
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Aging Bench Equipment and Procedures.... 86, App. VIII Appendix VIII to Part 86—Aging Bench Equipment and Procedures This appendix provides specifications for standard aging bench equipment and aging procedures which may be used to conduct bench aging...
The scanning cryomacroscope - A device prototype for the study of cryopreservation
NASA Astrophysics Data System (ADS)
Feig, Justin S. G.; Rabin, Yoed
2014-07-01
A new cryomacroscope prototype-a visualization device for the in situ analysis of cryopreserved biological samples-is presented in the current study. In order to visualize samples larger than the field of view of the optical setup, a scanning mechanism is integrated into the system, which represents a key improvement over previous cryomacroscope prototypes. Another key feature of the new design is in its compatibility with available top-loading controlled-rate cooling chambers, which eliminates the need for a dedicated cooling mechanism. The objective for the current development is to create means to generate a single digital movie of an experimental investigation, with all relevant data overlaid. The visualization capabilities of the scanning cryomacroscope are demonstrated in the current study on the cryoprotective agent dimethyl sulfoxide and the cryoprotective cocktail DP6. Demonstrated effects include glass formation, various regimes of crystallization, thermal contraction, and fracture formation.
Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, William J.; Chan, Wanyu R.; Hotchi, Toshifumi
2015-01-01
The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototypemore » measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s -1 (12.6 km h -1) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.« less
This document presents summary data on the results of various treatability studies (bench and pilot scale), conducted at three different sites where soils were contaminated with dioxins or PCBs. The synopsis is meant to show rough performance levels under a variety of differen...
40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)
Code of Federal Regulations, 2012 CFR
2012-07-01
.... VII Appendix VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging...
40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)
Code of Federal Regulations, 2013 CFR
2013-07-01
.... VII Appendix VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging...
Kynard, B.; Pugh, D.; Parker, T.
2011-01-01
Research and development of a fish ladder for sturgeons requires understanding ladder hydraulics and sturgeon behaviour in the ladder to insure the ladder is safe and provides effective passage. After years of research and development, we designed and constructed a full-scale prototype side-baffle ladder inside a spiral flume (38.3m long??1m wide??1m high) on a 6% (1:16.5) slope with a 1.92-m rise in elevation (bottom to top) to test use by sturgeons. Twenty-eight triangular side baffles, each extending part way across the flume, alternated from inside wall to outside wall down the ladder creating two major flow habitats: a continuous, sinusoidal flow down the ladder through the vertical openings of side-baffles and an eddy below each side baffle. Ascent and behaviour was observed on 22 cultured Lake Sturgeon=LS (Acipenser fulvescens) repeatedly tested in groups as juveniles (as small as 105.1cm TL, mean) or as adults (mean TL, 118cm) during four periods (fall 2002 and 2003; spring 2003 and 2007). Percent of juveniles entering the ladder that ascended to the top was greater in spring (72.7%) than in fall (40.9-45.5%) and 90.9% of 11 adults, which ascended as juveniles, ascended to the top. Six LS (27.3%) never swam to the top and seven (31.8%) swam to the top in all tests, indicating great variability among individuals for ascent drive. Some LS swam directly to the top in <1min, but most rested in an eddy during ascent. Juveniles swimming through outside wall baffle slots (mean velocity, 1.2ms-1) swam at 1.8-2.2body lengthss-1 and 3.2-3.3tail beatss-1, either at or approaching prolonged swimming speed. The side-baffle ladder was stream-like and provided key factors for a sturgeon ladder: a continuous flow and no full cross-channel walls, abundant eddies for resting, an acceptable water depth, and a water velocity fish could ascend swimming 2bls-1. A side-baffle ladder passes LS and other moderate-swimming fishes. ?? 2011 Blackwell Verlag, Berlin.
NASA Astrophysics Data System (ADS)
Gibson, Steve; Barnes, Stuart I.; Hearnshaw, John; Nield, Kathryn; Cochrane, Dave; Grobler, Deon
2012-09-01
A new advanced high resolution spectrograph has been developed by Kiwistar Optics of Industrial Research Ltd., New Zealand. The instrument, KiwiSpec R4-100, is bench-mounted, bre-fed, compact (0.75m by 1.5m footprint), and is well-suited for small to medium-sized telescopes. The instrument makes use of several advanced concepts in high resolution spectrograph design. The basic design follows the classical white pupil concept in an asymmetric implementation and employs an R4 echelle grating illuminated by a 100mm diameter collimated beam for primary dispersion. A volume phase holographic grating (VPH) based grism is used for cross-dispersion. The design also allows for up to four camera and detector channels to allow for extended wavelength coverage at high eciency. A single channel prototype of the instrument has been built and successfully tested with a 1m telescope. Targets included various spectrophotometric standard stars and several radial velocity standard stars to measure the instrument's light throughput and radial velocity capabilities. The prototype uses a 725 lines/mm VPH grism, an off-the-shelf camera objective, and a 2k×2k CCD. As such, it covers the wavelength range from 420nm to 660nm and has a resolving power of R ≍ 40,000. Spectrophotometric and precision radial velocity results from the on-sky testing period will be reported, as well as results of laboratory-based measurements. The optical design of KiwiSpec, and the various multi-channel design options, will be presented elsewhere in these proceedings.
Two-axis gimbal for air-to-air and air-to-ground laser communications
NASA Astrophysics Data System (ADS)
Talmor, Amnon G.; Harding, Harvard; Chen, Chien-Chung
2016-03-01
For bi-directional links between high-altitude-platforms (HAPs) and ground, and air-to-air communication between such platforms, a hemispherical +30°C field-of-regard and low-drag low-mass two-axis gimbal was designed and prototyped. The gimbal comprises two servo controlled non-orthogonal elevation over azimuth axis, and inner fast steering mirrors for fine field-of-regard adjustment. The design encompasses a 7.5cm diameter aperture refractive telescope in its elevation stage, folded between two flat mirrors with an exit lens leading to a two mirrors miniature Coude-path fixed to the azimuth stage. Multiple gimbal configurations were traded prior to finalizing a selection that met the requirements. The selected design was manifested onboard a carbon fiber and magnesium composite structure, motorized by custom-built servo motors, and commutated by optical encoders. The azimuth stage is electrically connected to the stationary base via slip ring while the elevation stage made of passive optics. Both axes are aligned by custom-built ceramic-on-steel angular contact duplex bearings, and controlled by embedded electronics featuring a rigid-flex PCB architecture. FEA analysis showed that the design is mechanically robust over a temperature range of +60°C to -80°C, and with first mode of natural frequencies above 400Hz. The total mass of the prototyped gimbal is 3.5kg, including the inner optical bench, which contains fast steering mirrors (FSMs) and tracking sensors. Future version of this gimbal, in prototyping stage, shall weigh less than 3.0kg.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simmons, R.; Thrun, S.; Armstrong, G.
1996-12-31
Amelia was built by Real World Interface (RWI) using Xavier-a mobile robot platform developed at CMU on a B24 base from RWI-as a prototype. Amelia has substantial engineering improvements over Xavier. Amelia is built on a B21 base. It has a top speed of 32 inches per second, while improved integral dead-reckoning insures extremely accurate drive and position controls.
A comparison of muscle activation between a Smith machine and free weight bench press.
Schick, Evan E; Coburn, Jared W; Brown, Lee E; Judelson, Daniel A; Khamoui, Andy V; Tran, Tai T; Uribe, Brandon P
2010-03-01
The bench press exercise exists in multiple forms including the machine and free weight bench press. It is not clear though how each mode differs in its effect on muscle activation. The purpose of this study was to compare muscle activation of the anterior deltoid, medial deltoid, and pectoralis major during a Smith machine and free weight bench press at lower (70% 1 repetition maximum [1RM]) and higher (90% 1RM) intensities. Normalized electromyography amplitude values were used during the concentric phase of the bench press to compare muscle activity between a free weight and Smith machine bench press. Participants were classified as either experienced or inexperienced bench pressers. Two testing sessions were used, each of which entailed either all free weight or all Smith machine testing. In each testing session, each participant's 1RM was established followed by 2 repetitions at 70% of 1RM and 2 repetitions at 90% of 1RM. Results indicated greater activation of the medial deltoid on the free weight bench press than on the Smith machine bench press. Also, there was greater muscle activation at the 90% 1RM load than at the 70% 1RM load. The results of this study suggest that strength coaches should consider choosing the free weight bench press over the Smith machine bench press because of its potential for greater upper-body muscular development.
Image-guided smart laser system for precision implantation of cells in cartilage
NASA Astrophysics Data System (ADS)
Katta, Nitesh; Rector, John A.; Gardner, Michael R.; McElroy, Austin B.; Choy, Kevin C.; Crosby, Cody; Zoldan, Janet; Milner, Thomas E.
2017-03-01
State-of-the-art treatment for joint diseases like osteoarthritis focus on articular cartilage repair/regeneration by stem cell implantation therapy. However, the technique is limited by a lack of precision in the physician's imaging and cell deposition toolkit. We describe a novel combination of high-resolution, rapid scan-rate optical coherence tomography (OCT) alongside a short-pulsed nanosecond thulium (Tm) laser for precise cell seeding in cartilage. The superior beam quality of thulium lasers and wavelength of operation 1940 nm offers high volumetric tissue removal rates and minimizes the residual thermal footprint. OCT imaging enables targeted micro-well placement, precise cell deposition, and feature contrast. A bench-top system is constructed using a 15 W, 1940 nm, nanosecond-pulsed Tm fiber laser (500 μJ pulse energy, 100 ns pulse duration, 30kHz repetition rate) for removing tissue, and a swept source laser (1310 ± 70 nm, 100 kHz sweep rate) for OCT imaging, forming a combined Tm/OCT system - a "smart laser knife". OCT assists the smart laser knife user in characterizing cartilage to inform micro-well placement. The Tm laser creates micro-wells (2.35 mm diameter length, 1.5 mm width, 300 μm deep) and micro-incisions (1 mm wide, 200 μm deep) while OCT image-guidance assists and demonstrates this precision cutting and cell deposition with real-time feedback. To test micro-well creation and cell deposition protocol, gelatin phantoms are constructed mimicking cartilage optical properties and physiological structure. Cell viability is then assessed to illustrate the efficacy of the hydrogel deposition. Automated OCT feedback is demonstrated for cutting procedures to avoid important surface/subsurface structures. This bench-top smart laser knife system described here offers a new image-guided approach to precise stem cell seeding that can enhance the efficacy of articular cartilage repair.
Madani, Amin; Watanabe, Yusuke; Townsend, Nicole; Pucher, Philip H; Robinson, Thomas N; Egerszegi, Patricia E; Olasky, Jaisa; Bachman, Sharon L; Park, Chan W; Amin, Nalin; Tang, David T; Haase, Erika; Bardana, Davide; Jones, Daniel B; Vassiliou, Melina; Fried, Gerald M; Feldman, Liane S
2016-02-01
Energy devices can result in devastating complications to patients. Yet, they remain poorly understood by trainees and surgeons. A single-institution pilot study suggested that structured simulation improves knowledge of the safe use of electrosurgery (ES) among trainees (Madani et al. in Surg Endosc 28(10):2772-2782, 2014). The purpose of this study was to estimate the extent to which the addition of this structured bench-top simulation improves ES knowledge across multiple surgical training programs. Trainees from 11 residency programs in Canada, the USA and UK participated in a 1-h didactic ES course, based on SAGES' Fundamental Use of Surgical Energy™ (FUSE) curriculum. They were then randomized to one of two groups: an unstructured hands-on session where trainees used ES devices (control group) or a goal-directed hands-on training session (Sim group). Pre- and post-curriculum (immediately and 3 months after) knowledge of the safe use of ES was assessed using separate examinations. Data are expressed as mean (SD) and N (%), *p < 0.05. A total of 289 (145 control; 144 Sim) trainees participated, with 186 (96 control; 90 Sim) completing the 3-month assessment. Baseline characteristics were similar between the two groups. Total score on the examination improved from 46% (10) to 84% (10)* for the entire cohort, with higher post-curriculum scores in the Sim group compared with controls [86% (9) vs. 83% (10)*]. All scores declined after 3 months, but remained higher in the Sim group [72% (18) vs. 64% (15)*]. Independent predictors of 3-month score included pre-curriculum score and participation in a goal-directed simulation. This multi-institutional study confirms that a 2-h curriculum based on the FUSE program improves surgical trainees' knowledge in the safe use of ES devices across training programs with various geographic locations and resident volumes. The addition of a structured interactive bench-top simulation component further improved learning.
Ahmad, Moiz; Bazalova-Carter, Magdalena; Fahrig, Rebecca; Xing, Lei
2015-05-01
In this work, we demonstrated that an optimized detector angular configuration based on the anisotropic energy distribution of background scattered X-rays improves X-ray fluorescence computed tomography (XFCT) detection sensitivity. We built an XFCT imaging system composed of a bench-top fluoroscopy X-ray source, a CdTe X-ray detector, and a phantom motion stage. We imaged a 6.4-cm-diameter phantom containing different concentrations of gold solution and investigated the effect of detector angular configuration on XFCT image quality. Based on our previous theoretical study, three detector angles were considered. The X-ray fluorescence detector was first placed at 145 (°) (approximating back-scatter) to minimize scatter X-rays. XFCT image quality was compared to images acquired with the detector at 60 (°) (forward-scatter) and 90 (°) (side-scatter). The datasets for the three different detector positions were also combined to approximate an isotropically arranged detector. The sensitivity was optimized with detector in the 145 (°) back-scatter configuration counting the 78-keV gold Kβ1 X-rays. The improvement arose from the reduced energy of scattered X-ray at the 145 (°) position and the large energy separation from gold K β1 X-rays. The lowest detected concentration in this configuration was 2.5 mgAu/mL (or 0.25% Au with SNR = 4.3). This concentration could not be detected with the 60 (°) , 90 (°) , or isotropic configurations (SNRs = 1.3, 0, 2.3, respectively). XFCT imaging dose of 14 mGy was in the range of typical clinical X-ray CT imaging doses. To our knowledge, the sensitivity achieved in this experiment is the highest in any XFCT experiment using an ordinary bench-top X-ray source in a phantom larger than a mouse ( > 3 cm).
Iramina, Hiraku; Hamaguchi, Takumi; Nakamura, Mitsuhiro; Mizowaki, Takashi; Kanno, Ikuo
2018-04-30
We evaluated two dual-energy cone-beam computed tomography (DE-CBCT) methodologies for a bench-top micro-CBCT system to reduce metal artifacts on reconstructed images. Two filter-based DE-CBCT methodologies were tested: (i) alternative spectral switching and (ii) simultaneous beam splitting. We employed filters of 0.6-mm-thick tin and 0.1-mm-thick tungsten to generate high- and low-energy spectra from 120 kVp X-rays, respectively. The spectral switching method was imitated by two half scans with different filters (pseudo-switching). Filters were placed and between the X-ray tube and a phantom ('1-u,' '2-u'), a phantom and a flat panel detector ('1-d,' '2-d'), and compared with (iii) two half scans at 80 and 140 kVp [pseudo-(80,140)]. For the splitting method, two half-width filters were aligned along a rotating axis. Projections were separated into halves and merged with corresponding areas of opposed projections after one full rotation. A solid 30-mm-diameter acrylic phantom and an acrylic phantom with four 5-mm-diameter titanium rods were used. DE images were generated by weighted summation of the high- and low-energy images. The blending factor was changed from 0 to +5 in increments of 0.01. Relative errors (REs) of the linear attenuation coefficients of the two phantoms and the contrast-to-noise ratios (CNRs) between the titanium and acrylic regions were compared. All methods showed zero REs except for the method (2-d). CNRs for pseudo-switching with upstream placement were 1.4-fold larger than CNRs for the pseudo-(80,140) method. CNRs for the downstream placements were small. It was concluded that the pseudo-switching method with upstream placement is appropriate for reducing metal artifacts.
Wilkinson, Samuel L.; John, Shibu; Walsh, Roddy; Novotny, Tomas; Valaskova, Iveta; Gupta, Manu; Game, Laurence; Barton, Paul J R.; Cook, Stuart A.; Ware, James S.
2013-01-01
Background Molecular genetic testing is recommended for diagnosis of inherited cardiac disease, to guide prognosis and treatment, but access is often limited by cost and availability. Recently introduced high-throughput bench-top DNA sequencing platforms have the potential to overcome these limitations. Methodology/Principal Findings We evaluated two next-generation sequencing (NGS) platforms for molecular diagnostics. The protein-coding regions of six genes associated with inherited arrhythmia syndromes were amplified from 15 human samples using parallelised multiplex PCR (Access Array, Fluidigm), and sequenced on the MiSeq (Illumina) and Ion Torrent PGM (Life Technologies). Overall, 97.9% of the target was sequenced adequately for variant calling on the MiSeq, and 96.8% on the Ion Torrent PGM. Regions missed tended to be of high GC-content, and most were problematic for both platforms. Variant calling was assessed using 107 variants detected using Sanger sequencing: within adequately sequenced regions, variant calling on both platforms was highly accurate (Sensitivity: MiSeq 100%, PGM 99.1%. Positive predictive value: MiSeq 95.9%, PGM 95.5%). At the time of the study the Ion Torrent PGM had a lower capital cost and individual runs were cheaper and faster. The MiSeq had a higher capacity (requiring fewer runs), with reduced hands-on time and simpler laboratory workflows. Both provide significant cost and time savings over conventional methods, even allowing for adjunct Sanger sequencing to validate findings and sequence exons missed by NGS. Conclusions/Significance MiSeq and Ion Torrent PGM both provide accurate variant detection as part of a PCR-based molecular diagnostic workflow, and provide alternative platforms for molecular diagnosis of inherited cardiac conditions. Though there were performance differences at this throughput, platforms differed primarily in terms of cost, scalability, protocol stability and ease of use. Compared with current molecular genetic diagnostic tests for inherited cardiac arrhythmias, these NGS approaches are faster, less expensive, and yet more comprehensive. PMID:23861798
NASA Astrophysics Data System (ADS)
Schatz, Konrad; Friedrich, Bretislav; Becker, Simon; Schmidt, Burkhard
2018-05-01
We make use of the quantum Hamilton-Jacobi (QHJ) theory to investigate conditional quasisolvability of the quantum symmetric top subject to combined electric fields (symmetric top pendulum). We derive the conditions of quasisolvability of the time-independent Schrödinger equation as well as the corresponding finite sets of exact analytic solutions. We do so for this prototypical trigonometric system as well as for its anti-isospectral hyperbolic counterpart. An examination of the algebraic and numerical spectra of these two systems reveals mutually closely related patterns. The QHJ approach allows us to retrieve the closed-form solutions for the spherical and planar pendula and the Razavy system that had been obtained in our earlier work via supersymmetric quantum mechanics as well as to find a cornucopia of additional exact analytic solutions.
Depositional history of the Fire Clay coal bed (Late Duckmantian), Eastern Kentucky, USA
Greb, S.F.; Eble, C.F.; Hower, J.C.
1999-01-01
More than 3800 coal thickness measurements, proximate analyses from 97 localities, and stratigraphic and sedimentological analyses from more than 300 outcrops and cores were used in conjunction with previously reported palynological and petrographic studies to map individual benches of the coal and document bench-scale variability in the Fire Clay (Hazard No. 4) coal bed across a 1860 km2 area of the Eastern Kentucky Coal Field. The bench architecture of the Fire Clay coal bed consists of uncommon leader benches, a persistent but variable lower bench, a widespread, and generally thick upper bench, and local, variable rider benches. Rheotrophic conditions are inferred for the leader benches and lower bench based on sedimentological associations, mixed palynomorph assemblages, locally common cannel coal layers, and generally high ash yields. The lower bench consistently exhibits vertical variability in petrography and palynology that reflects changing trophic conditions as topographic depressions infilled. Infilling also led to unconfined flooding and ultimately the drowning of the lower bench mire. The drowned mire was covered by an air-fall volcanic-ash deposit, which produced the characteristic flint clay parting. The extent and uniform thickness of the parting suggests that the ash layer was deposited in water on a relatively flat surface without a thick canopy or extensive standing vegetation across most of the study area. Ash deposits led to regional ponding and establishment of a second planar mire. Because the topography had become a broadly uniform, nutrient-rich surface, upper-bench peats became widespread with large areas of the mire distant to clastic sources. Vertical sections of thick (> 70 cm), low-ash yield, upper coal bench show a common palynomorph change from arborescent lycopod dominance upward to fern and densospore-producing, small lycopod dominance, inferred as a shift from planar to ombrotrophic mire phases. Domed mires appear to have been surrounded by wide areas of planar mires, where the coal was thinner (< 70 cm), higher in ash yield, and dominated by arborescent lycopods. Rectangular thickness trends suggest that syndepositional faulting influenced peat accumulation, and possibly the position of the domed mire phase. Faulting also influenced post-depositional clastic environments of deposition, resulting in sandstone channels with angular changes in orientation. Channels and lateral facies were locally draped by high-ash-yield rider coal benches, which sometimes merged with the upper coal bench. These arborescent-lycopod dominant rider coal benches were profoundly controlled by palcotopography, much like the leader coal benches. Each of the benches of coal documented here represent distinctly different mires that came together to form the Fire Clay coal bed, rather than a single mire periodically split by clastic influx. This is significant as each bench of the coal has its own characteristics, which contribute to the total coal characteristics. The large data set allows interpretation of both vertical and lateral limits to postulated domed phases in the upper coal bench, and to the delineation of subtle tectonic structures that allow for meaningful thickness projections beyond the limits of present mining.A study was conducted to analyze the depositional history of the Fire Clay coal bed in the eastern Kentucky coal field. The study involved over 3800 coal thickness measurements, proximate analyses from 97 localities, and stratigraphic and sedimentological analyses from more than 300 outcrops and cores in conjunction with previously reported palynological and petrographic studies to map individual benches of the coal and document bench-scale variability.
Martín, Ferran; Bonache, Jordi
2014-01-01
In this review paper, several strategies for the implementation of reconfigurable split ring resonators (SRRs) based on RF-MEMS switches are presented. Essentially three types of RF-MEMS combined with split rings are considered: (i) bridge-type RF-MEMS on top of complementary split ring resonators CSRRs; (ii) cantilever-type RF-MEMS on top of SRRs; and (iii) cantilever-type RF-MEMS integrated with SRRs (or RF-MEMS SRRs). Advantages and limitations of these different configurations from the point of view of their potential applications for reconfigurable stopband filter design are discussed, and several prototype devices are presented. PMID:25474378
Fused silica windows for solar receiver applications
NASA Astrophysics Data System (ADS)
Hertel, Johannes; Uhlig, Ralf; Söhn, Matthias; Schenk, Christian; Helsch, Gundula; Bornhöft, Hansjörg
2016-05-01
A comprehensive study of optical and mechanical properties of quartz glass (fused silica) with regard to application in high temperature solar receivers is presented. The dependence of rupture strength on different surface conditions as well as high temperature is analyzed, focussing particularly on damage by devitrification and sandblasting. The influence of typical types of contamination in combination with thermal cycling on the optical properties of fused silica is determined. Cleaning methods are compared regarding effectiveness on contamination-induced degradation for samples with and without antireflective coating. The FEM-aided design of different types of receiver windows and their support structure is presented. A large-scale production process has been developed for producing fused silica dome shaped windows (pressurized window) up to a diameter of 816 mm. Prototypes were successfully pressure-tested in a test bench and certified according to the European Pressure Vessel Directive.
A Front-End electronics board for single photo-electron timing and charge from MaPMT
NASA Astrophysics Data System (ADS)
Giordano, F.; Breton, D.; Beigbeder, C.; De Robertis, G.; Fusco, P.; Gargano, F.; Liuzzi, R.; Loparco, F.; Mazziotta, M. N.; Rizzi, V.; Tocut, V.
2013-08-01
A Front-End (FE) design based on commercial operational amplifiers has been developed to read-out signals from a Multianode PhotoMultiplier Tube (MaPMT). The overall design has been optimised for single photo-electron signal from the Hamamatsu H8500. The signal is collected by a current sensitive preamplifier and then it is fed into both a ECL fast discriminator and a shaper for analog output readout in differential mode. The analog signal and the digital gates are then registered on VME ADC and TDC modules respectively. Performances in terms of linearity, gain and timing resolution will be discussed, presenting results obtained on a test bench with differentiated step voltage inputs and also with a prototype electronic board plugged into the H8500 PMT illuminated by a picosecond laser.
Design and specification of a centralized manufacturing data management and scheduling system
NASA Technical Reports Server (NTRS)
Farrington, Phillip A.
1993-01-01
As was revealed in a previous study, the Materials and Processes Laboratory's Productivity Enhancement Complex (PEC) has a number of automated production areas/cells that are not effectively integrated, limiting the ability of users to readily share data. The recent decision to utilize the PEC for the fabrication of flight hardware has focused new attention on the problem and brought to light the need for an integrated data management and scheduling system. This report addresses this need by developing preliminary designs specifications for a centralized manufacturing data management and scheduling system for managing flight hardware fabrication in the PEC. This prototype system will be developed under the auspices of the Integrated Engineering Environment (IEE) Oversight team and the IEE Committee. At their recommendation the system specifications were based on the fabrication requirements of the AXAF-S Optical Bench.
Cost analysis of oxygen recovery systems
NASA Technical Reports Server (NTRS)
Yakut, M. M.
1973-01-01
The design and development of equipment for flight use in earth-orbital programs, when optimally approached cost effectively, proceed through the following logical progression: (1) bench testing of breadboard designs, (2) the fabrication and evaluation of prototype equipment, (3) redesign to meet flight-imposed requirements, and (4) qualification and testing of a flight-ready system. Each of these steps is intended to produce the basic design information necessary to progress to the next step. The cost of each step is normally substantially less than that of the following step. An evaluation of the cost elements involved in each of the steps and their impact on total program cost are presented. Cost analyses of four leading oxygen recovery subsystems which include two carbon dioxide reduction subsystem, Sabatier and Bosch, and two water electrolysis subsystems, the solid polymer electrolyte and the circulating KOH electrolyte are described.
Endoscope shaft-rigidity control mechanism: "FORGUIDE".
Loeve, Arjo J; Plettenburg, Dick H; Breedveld, Paul; Dankelman, Jenny
2012-02-01
Recent developments in flexible endoscopy and other fields of medical technology have raised the need for compact slender shafts that can be made rigid and compliant at will. A novel compact mechanism, named FORGUIDE, with this functionality was developed. The FORGUIDE shaft rigidifies due to friction between a ring of cables situated between a spring and an inflated tube. A mathematical model for the FORGUIDE mechanism working principle was made and used to obtain understanding of this mechanism, predict the maximum rigidity of a FORGUIDE shaft design, and tune its design variables. The mathematical model gave suggestions for significant performance improvement by fine-tuning the design. A prototype FORGUIDE shaft was built and put to a series of bench tests. These tests showed that the FORGUIDE mechanism provides a reliable and simple way to control the rigidity of a flexible shaft. © 2011 IEEE
Recovery of ammonia from poultry litter using flat gas permeable membranes.
Rothrock, M J; Szögi, A A; Vanotti, M B
2013-06-01
The use of flat gas-permeable membranes was investigated as components of a new process to capture and recover ammonia (NH3) in poultry houses. This process includes the passage of gaseous NH3 through a microporous hydrophobic membrane, capture with a circulating dilute acid on the other side of the membrane, and production of a concentrated ammonium (NH4) salt. Bench- and pilot-scale prototype systems using flat expanded polytetrafluoroethylene (ePTFE) membranes and a sulfuric acid solution consistently reduced headspace NH3 concentrations from 70% to 97% and recovered 88% to 100% of the NH3 volatilized from poultry litter. The potential benefits of this technology include cleaner air inside poultry houses, reduced ventilation costs, and a concentrated liquid ammonium salt that can be used as a plant nutrient solution. Published by Elsevier Ltd.
Optical Methods For Automatic Rating Of Engine Test Components
NASA Astrophysics Data System (ADS)
Pritchard, James R.; Moss, Brian C.
1989-03-01
In recent years, increasing commercial and legislative pressure on automotive engine manufacturers, including increased oil drain intervals, cleaner exhaust emissions and high specific power outputs, have led to increasing demands on lubricating oil performance. Lubricant performance is defined by bench engine tests run under closely controlled conditions. After test, engines are dismantled and the parts rated for wear and accumulation of deposit. This rating must be consistently carried out in laboratories throughout the world in order to ensure lubricant quality meeting the specified standards. To this end, rating technicians evaluate components, following closely defined procedures. This process is time consuming, inaccurate and subject to drift, requiring regular recalibration of raters by means of international rating workshops. This paper describes two instruments for automatic rating of engine parts. The first uses a laser to determine the degree of polishing of the engine cylinder bore, caused by the reciprocating action of piston. This instrument has been developed to prototype stage by the NDT Centre at Harwell under contract to Exxon Chemical, and is planned for production within the next twelve months. The second instrument uses red and green filtered light to determine the type, quality and position of deposit formed on the piston surfaces. The latter device has undergone feasibility study, but no prototype exists.
Pearson, Simon N; Cronin, John B; Hume, Patria A; Slyfield, David
2009-09-01
Understanding how loading affects power production in resistance training is a key step in identifying the most optimal way of training muscular power - an essential trait in most sporting movements. Twelve elite male sailors with extensive strength-training experience participated in a comparison of kinematics and kinetics from the upper body musculature, with upper body push (bench press) and pull (bench pull) movements performed across loads of 10-100% of one repetition maximum (1RM). 1RM strength and force were shown to be greater in the bench press, while velocity and power outputs were greater for the bench pull across the range of loads. While power output was at a similar level for the two movements at a low load (10% 1RM), significantly greater power outputs were observed for the bench pull in comparison to the bench press with increased load. Power output (Pmax) was maximized at higher relative loads for both mean and peak power in the bench pull (78.6 +/- 5.7% and 70.4 +/- 5.4% of 1RM) compared to the bench press (53.3 +/- 1.7% and 49.7 +/- 4.4% of 1RM). Findings can most likely be attributed to differences in muscle architecture, which may have training implications for these muscles.
Performance evaluation of an automotive thermoelectric generator
NASA Astrophysics Data System (ADS)
Dubitsky, Andrei O.
Around 40% of the total fuel energy in typical internal combustion engines (ICEs) is rejected to the environment in the form of exhaust gas waste heat. Efficient recovery of this waste heat in automobiles can promise a fuel economy improvement of 5%. The thermal energy can be harvested through thermoelectric generators (TEGs) utilizing the Seebeck effect. In the present work, a versatile test bench has been designed and built in order to simulate conditions found on test vehicles. This allows experimental performance evaluation and model validation of automotive thermoelectric generators. An electrically heated exhaust gas circuit and a circulator based coolant loop enable integrated system testing of hot and cold side heat exchangers, thermoelectric modules (TEMs), and thermal interface materials at various scales. A transient thermal model of the coolant loop was created in order to design a system which can maintain constant coolant temperature under variable heat input. Additionally, as electrical heaters cannot match the transient response of an ICE, modelling was completed in order to design a relaxed exhaust flow and temperature history utilizing the system thermal lag. This profile reduced required heating power and gas flow rates by over 50%. The test bench was used to evaluate a DOE/GM initial prototype automotive TEG and validate analytical performance models. The maximum electrical power generation was found to be 54 W with a thermal conversion efficiency of 1.8%. It has been found that thermal interface management is critical for achieving maximum system performance, with novel designs being considered for further improvement.
NASA Astrophysics Data System (ADS)
McHugh, K. M.; Key, J. F.
The United States Council for Automotive Research (USCAR) has formed a partnership with the Idaho National Engineering Laboratory (INEL) to develop a process for the rapid production of low-cost tooling based on spray forming technology developed at the INEL. Phase 1 of the program will involve bench-scale system development, materials characterization, and process optimization. In Phase 2, prototype systems will be designed, constructed, evaluated, and optimized. Process control and other issues that influence commercialization will be addressed during this phase of the project. Technology transfer to USCAR, or a tooling vendor selected by USCAR, will be accomplished during Phase 3. The approach INEL is using to produce tooling, such as plastic injection molds and stamping dies, combines rapid solidification processing and net-shape materials processing into a single step. A bulk liquid metal is pressure-fed into a de Laval spray nozzle transporting a high velocity, high temperature inert gas. The gas jet disintegrates the metal into fine droplets and deposits them onto a tool pattern made from materials such as plastic, wax, clay, ceramics, and metals. The approach is compatible with solid freeform fabrication techniques such as stereolithography, selective laser sintering, and laminated object manufacturing. Heat is extracted rapidly, in-flight, by convection as the spray jet entrains cool inert gas to produce undercooled and semi-solid droplets. At the pattern, the droplets weld together while replicating the shape and surface features of the pattern. Tool formation is rapid; deposition rates in excess of 1 ton/h have been demonstrated for bench-scale nozzles.
NASA Astrophysics Data System (ADS)
Fujihara, Kento; Emoto, Yusaku; Ito, Hiroshi; Kaneko, Naomi; Kaneko, Hideyuki; Kawai, Hideyuki; Kobayashi, Atsushi; Mizuno, Takahiro
2018-01-01
Existing PET (Positron Emission Tomography) systems make clear images in demonstration (measuring small PET reagent in pure water), however images in real diagnosis become unclear. The authors suspected that this problem was caused by Compton scattering in a detector. When PET systems observe plural photomultiplier tube outputs, an original emission point is regarded as centroid of the outputs. However, even if plural emission in Compton scattering occur, these systems calculate original point in the same way as single emission. Therefore, the authors considered that rejecting Compton scattering events makes PET systems much better, and made prototype counter. Main components of the prototype counter are plate-like high-growth-rate (HGR) La-GPS scintillators and wavelength shifting fibers (WLSF). HGR crystals grow 10 times as fast as a mono-crystal (a normal mono-crystal grows at 2 - 3 mm an hour). Thus, it includes microbubble and its transparency get worth. Consequently, HGR crystals usually are not used in radiation measuring instruments. However, this time they are used on the purpose. Because of their low transparency, scintillation lights come out right above and right under of emission position. Therefore, Compton scattering events is rejected easily. The prototype detector has an effective area of 300 by 300 square mm. The detector consists of 24 layers. One layer consists of HGR La-GPS scintillator of 1 mm thickness. Top and bottom surface of scintillator were covered by dual sheets of WLSF with a diameter of 0.2 mm. Sheets of WLSF on top and bottom of the scintillator make a right angle with each other, and measure X- and Y-components. Z-component is measured by difference of WLSF outputs between top and bottom. If plural layers output signals, this counter regards the event as Compton scattering event, and reject the event. Even if only a layer output signals, the event is rejected when number output signals from WLSF is more than 1.5 times of single emission. Material cost of this system is, 0.2M for HGR La-GPS, 0.03M for WLSF, 0.03M for 600 units of 6 by 6 mm SiPM's, 0.12M for 12000 units of 1 by 1 mm SiPM's, and 0.09M for 1800 channel of signal readout circuits. Considering total cost, price of this PET will be set 1M or less. This idea was confirmed with numerical simulation and experimentation. In experimentation, position resolution in photoelectric absorption was 0.2 mm, and minimum distance that this detector could recognize plural emission in Compton scattering was 1 mm. In parallel, three kinds of model were made: a prototype detector, all the signals readout method, and resistance delay method. Simulation setting was 2 MBq/L in normal tissue and 10 MBq/L in cancer. As a result of simulation, a prototype detector identified 3 mm cancer, however the others made unclear image and was not able to identified cancer. That is to say, the prototype detector is able to reject Compton scattering events and inexpensive. Therefore, whole-body PET system with this detector must diagnose cancer with a diameter of 3 mm or more and be priced 1M or less
Rogers, Benjamin H.; Brown, Justin C.; Gater, David R.; Schmitz, Kathryn H.
2016-01-01
Objective One-repetition maximum (1-RM) bench press strength is considered the gold standard to quantify upper-body muscular strength. Isometric handgrip strength is frequently used as a surrogate for 1-RM bench press strength among breast cancer (BrCa) survivors. The relationship between 1-RM bench press strength and isometric handgrip strength, however, has not been characterized among BrCa survivors. Design Cross-sectional study. Setting Laboratory. Participants Community-dwelling BrCa survivors. Interventions Not applicable. Main Outcome Measure 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer with three maximal contractions of left and right hands. All measures were conducted by staff with training in clinical exercise testing. Results Among 295 BrCa survivors, 1-RM bench press strength was 18.2±6.1 kg (range: 2.2-43.0) and isometric handgrip strength was 23.5±5.8 kg (range: 9.0-43.0). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=0.399; P<0.0001). Mean-difference analysis suggested that the average isometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7 kg (95% limits of agreement: −8.2 to 17.6). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=0.31; P<0.0001) and age (β=−0.20; P<0.0001) were positively correlated with 1-RM bench press strength (R2=0.23). Conclusions Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among BrCa survivors. 1-RM bench press and isometric handgrip strength quantify distinct components of muscular strength. PMID:27543047
NASA Astrophysics Data System (ADS)
Tang, Q. C.; Yang, Y. L.; Li, Xinxin
2011-12-01
This paper presents miniaturized energy harvesters, where the frequency up-conversion technique is used to improve the bandwidth of vibration energy harvesters. The proposed and developed miniature piezoelectric energy harvester utilizes magnetic repulsion forces to achieve non-contact frequency up-conversion, thereby avoiding mechanical collision and wear for long-term working durability. A pair of piezoelectric resonant cantilevers is micro-fabricated to generate electric power. A simplified model involving linear oscillators and magnetic interaction is deployed to demonstrate the feasibility of the device design. A bench-top harvester has been fabricated and characterized, resulting in average power generation of over 10 µW within a broad frequency range of 10-22 Hz under 1g acceleration.
Neglecting safety precautions may lead to trenching fatalities.
Deatherage, J Harold; Furches, Lisa K; Radcliffe, Mike; Schriver, William R; Wagner, John P
2004-06-01
Trench collapses ranked as the seventh leading cause of the possible twenty-nine causes of OSHA-inspected fatal construction events during the period 1991-2001. This study aims to examine why these fatalities occurred. Forty-four case files from OSHA inspections of fatal trench collapses were reviewed. Improper protection of the excavation site where work was taking place was the leading fatality cause. Several organizational or physical conditions were present at many fatal sites; the most frequent was that no training had been provided for trenching. Presence of a competent, diligent person at the site would have prohibited most fatalities. The top cited violation was lack of protection, that is, benching, shoring, sloping, trench boxes, etc. (29 CFR 1926.652 (a) (1)). Copyright 2004 Wiley-Liss, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hellemans, A.
Space beam weapons and unlimited energy from fusion may have been pipe dreams of the 1980s. But today these dreams are giving birth to practical laboratory tools: tabletop x-ray lasers that may open up whole new areas of chemistry and biology. The first x-ray lasers were energized by nuclear explosions or jolts of light from giant glass lasers built for fusion experiments-hardly bench-top equipment. Now, says Joseph Nilsen, a physicist at Lawrence Livermore National Laboratory (LLNL), {open_quotes}several small university-size places are actually making a lot of progress toward tabletop lasers people can use every day.{close_quotes} This article highlight progress towardsmore » cheap ubiquitous X-ray lasers as described at the 5th International Conference on X-ray Lasers.« less
Biological activity of common mullein, a medicinal plant.
Turker, Arzu Ucar; Camper, N D
2002-10-01
Common Mullein (Verbascum thapsus L., Scrophulariaceae) is a medicinal plant that has been used for the treatment of inflammatory diseases, asthma, spasmodic coughs, diarrhea and other pulmonary problems. The objective of this study was to assess the biological activity of Common Mullein extracts and commercial Mullein products using selected bench top bioassays, including antibacterial, antitumor, and two toxicity assays--brine shrimp and radish seed. Extracts were prepared in water, ethanol and methanol. Antibacterial activity (especially the water extract) was observed with Klebsiella pneumonia, Staphylococcus aureus, Staphylococcus epidermidis and Escherichia coli. Agrobacterium tumefaciens-induced tumors in potato disc tissue were inhibited by all extracts. Toxicity to Brine Shrimp and to radish seed germination and growth was observed at higher concentrations of the extracts.
Portable gas chromatograph-mass spectrometer
Andresen, Brian D.; Eckels, Joel D.; Kimmons, James F.; Myers, David W.
1996-01-01
A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.
NASA Astrophysics Data System (ADS)
Hunter, Hazel M. A.; Makepeace, Joshua W.; Wood, Thomas J.; Mylius, O. Simon; Kibble, Mark G.; Nutter, Jamie B.; Jones, Martin O.; David, William I. F.
2016-10-01
Accessing the intrinsic hydrogen content within ammonia, NH3, has the potential to play a very significant role in the future of a CO2-free sustainable energy supply. Inexpensive light metal imides and amides are effective at decomposing ammonia to hydrogen and nitrogen (2NH3 → 3H2 + N2), at modest temperatures, and thus represent a low-cost approach to on-demand hydrogen production. Building upon this discovery, this paper describes the integration of an ammonia cracking unit with a post-reactor gas purification system and a small-scale PEM fuel cell to create a first bench-top demonstrator for the production of hydrogen using light metal imides.
Czugala, Monika; Gorkin, Robert; Phelan, Thomas; Gaughran, Jennifer; Curto, Vincenzo Fabio; Ducrée, Jens; Diamond, Dermot; Benito-Lopez, Fernando
2012-12-07
This work describes the first use of a wireless paired emitter detector diode device (PEDD) as an optical sensor for water quality monitoring in a lab-on-a-disc device. The microfluidic platform, based on an ionogel sensing area combined with a low-cost optical sensor, is applied for quantitative pH and qualitative turbidity monitoring of water samples at point-of-need. The autonomous capabilities of the PEDD system, combined with the portability and wireless communication of the full device, provide the flexibility needed for on-site water testing. Water samples from local fresh and brackish sources were successfully analysed using the device, showing very good correlation with standard bench-top systems.
Capsule endoscopy of the future: What’s on the horizon?
Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro
2015-01-01
Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today’s standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years. PMID:26457013
Tainter Gate Tests, Norfork Dam, North Fork River, Arkansas: Model and Prototype Investigations
1954-06-01
the sides and top of the conduit while the bottom of the gate was sealed in a recess provided in the lead bottom seal. Later a rubber seal was also...the lifting strut were about the same whether or not flow was passing the gate. During the gate closure procedure, however, the data indiGate 24 that
Relationship of pectoralis major muscle size with bench press and bench throw performances.
Akagi, Ryota; Tohdoh, Yukihiro; Hirayama, Kuniaki; Kobayashi, Yuji
2014-06-01
This study examined the relationship of muscle size indices of the pectoralis major muscle with bench press and bench throw performances in 18 male collegiate athletes. The maximal cross-sectional area (MCSAMAx) and volume (MV) of the pectoralis major muscle were determined by magnetic resonance imaging. First, subjects were tested for their one repetition maximum bench press strength (1RMBP) using a Smith machine. At a later date, subjects performed bench throws using the Smith machine with several different loads ranging from 30.0 kg to 90% of 1RMBP. Barbell positions were measured by a linear position transducer, and bench throw power was calculated using a dynamic equation. Three trials were performed for each load. In all the trials, the maximal peak power was adopted as bench throw peak power (PPBT). The 1RMBP was significantly correlated with MCSAMAx. Similarly, the correlation coefficient between MV and PPBT was significant. In contrast to the y-intercept of the MV-PPBT regression line, that of the MCSAMAx-1RMBP regression line was not significantly different from 0. These results suggested that, although the dependence on pectoralis major muscle size is slightly different between bench press strength and bench throw power, the pectoralis major muscle size has a significant impact on bench press and throw performances. Greater muscle size leads to heavier body weight, which can be a negative factor in some sports. We therefore recommend that athletes and their coaches develop training programs for improving sports performance by balancing the advantage of increased muscle size and the potential disadvantage of increased body weight.
Measurement of fission product gases in the atmosphere
NASA Astrophysics Data System (ADS)
Schell, W. R.; Tobin, M. J.; Marsan, D. J.; Schell, C. W.; Vives-Batlle, J.; Yoon, S. R.
1997-01-01
The ability to quickly detect and assess the magnitude of releases of fission-produced radioactive material is of significant importance for ongoing operations of any conventional nuclear power plant or other activities with a potential for fission product release. In most instances, the control limits for the release of airborne radioactivity are low enough to preclude direct air sampling as a means of detection, especially for fission gases that decay by beta or electron emission. It is, therefore, customary to concentrate the major gaseous fission products (krypton, xenon and iodine) by cryogenic adsorption for subsequent separation and measurement. This study summarizes our initial efforts to develop an automated portable system for on-line separation and concentration with the potential for measuring environmental levels of radioactive gases, including 85Kr, 131,133,135Xe, 14C, 3H, 35S, 125,131I, etc., without using cryogenic fluids. Bench top and prototype models were constructed using the principle of heatless fractionation of the gases in a pressure swing system. This method removes the requirement for cryogenic fluids to concentrate gases and, with suitable electron and gamma ray detectors, provides for remote use under automatic computer control. Early results using 133Xe tracer show that kinetic chromatography, i.e., high pressure adsorption of xenon and low pressure desorption of air, using specific types of molecular sieves, permits the separation and quantification of xenon isotopes from large volume air samples. We are now developing the ability to measure the presence and amounts of fission-produced xenon isotopes that decay by internal conversion electrons and beta radiation with short half-lives, namely 131mXe, 11.8 d, 133mXe, 2.2 d, 133Xe, 5.2 d and 135Xe, 9.1 h. The ratio of the isotopic concentrations measured can be used to determine unequivocally the amount of fission gas and time of release of an air parcel many kilometers downwind from a nuclear activity where the fission products were discharged.
NASA Astrophysics Data System (ADS)
Hoffmann, Alex; Huebner, Marko; Macleod, Neil; Weidmann, Damien
2016-04-01
Over the course of the last decade, the Laser Spectroscopy Group at RAL Space has considerably furthered the passive remote sensing technique of thermal IR Laser Heterodyne Radiometry (LHR), and applied it successfully to the ground-based sounding of atmospheric profiles of a variety of trace gases, including methane. LHR is underpinned by coherent detection technology and ideally shot noise-limited, which can significantly enhance the signal-to-noise ratio of acquired atmospheric spectra over conventional direct detection spectrometers when high spectral (>500,000 resolving power) and high spatial resolutions are needed. These benefits allow probing optimized narrow spectral windows (1 cm-1) with full absorption lineshape information, useful for trace gas vertical profiling. Furthermore, LHR has a high potential for miniaturization into a rugged, unprecedentedly compact package, through hollow waveguide optical integration, facilitating its deployment in ground-based observation networks, as well as on a variety of airborne and spaceborne platforms, whilst retaining its high specifications. This makes LHR well-suited to the remote sounding of key greenhouse gases, in particular carbon dioxide, as observations with high precision and accuracy are crucial to discriminate trends and small variations over a substantial background concentration, and in order to contribute to flux estimations in top-down carbon cycle inversion approaches and anthropogenic emission monitoring. Here, we present a new optical bench-based LHR prototype that has been specifically built to demonstrate CO2 sounding in the thermal IR. The instrument has been coupled to a new permanently installed solar tracker to take a long-term measurement series in solar occultation mode, and to assess the performance of the instrument. We discuss its theoretical performance modelled using an Observation System Simulator, and showcase first results from a 6 months' archive, with observations undergoing gradual refinement as the retrieval method is improved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, H; Ding, H; Molloi, S
Purpose: To investigate the feasibility of micro-calcification (μCa) detectability by using an energy-resolved photon-counting Si strip detector for spectral breast computed tomography (CT). Methods: A bench-top CT system was constructed using a tungsten anode x-ray source with a focal spot size of 0.8 mm and a single line 256-pixel Si strip photon counting detector with a pixel pitch of 100 μm. The slice thickness was 0.5 mm. Five different size groups of calcium carbonate grains, from 105 to 215 μm in diameter, were embedded in a cylindrical resin phantom with a diameter of 16 mm to simulate μCas. The phantomsmore » were imaged at 65 kVp with an Entrance Skin Air Kerma (ESAK) of 1.2, 3, 6, and 8 mGy. The images were reconstructed using a standard filtered back projection (FBP) with a ramp filter. A total of 200 μCa images (5 different sizes of μCas × 4 different doses × 10 images for each setting) were combined with another 200 control images without μCas, to ultimately form 400 images for the reader study. The images were displayed in random order to three blinded observers, who were asked to give a binary score on each image regarding the presence of μCas. The μCa detectability for each image was evaluated in terms of binary decision theory metrics. The sensitivity, specificity, and accuracy were calculated to study the size and dose-dependence for μCa detectability. Additionally, the influence of the partial volume effect on the μCa detectability was investigated by simulation. Results: For a μCa larger than 140 μm in diameter, detection accuracy of above 90 % was achieved with the investigated prototype spectral CT system at ESAK of 1.2 mGy. Conclusion: The proposed Si strip detector is expected to offer superior image quality with the capability to detect μCas for low dose breast imaging.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortiz, E.; Valdés-Galicia, J. F.; Matsubara, Y.
In this work we report the flux of protons and neutral emission measured at the top of the Sierra Negra volcano at 4600 m.a.s.l. (575 g/cm2), in Eastern Mexico. As an example of the capability of the mini-SciCR as a cosmic ray detector we present the Forbush decrease recorded on March 7, 2012. These data were obtained with a cosmic ray detector prototype called mini-SciCR that was operating from October 2010 to July 2012. Our main aims were to measure the hadronic component flux of the secondary cosmic ray and to show the appropriate performance of all system of themore » detector. To separate the signals of protons from other charged particles we obtained the energy deposition pattern when they cross the detector using a Monte Carlo simulation, and to separate the signals of neutral emission we used an anticoincidence system between the edge bars and the internal bars of the detector. The mini-SciCR is a prototype of a new cosmic ray detector called SciBar Cosmic Ray Telescope (SciCRT) installed in the same place, which is in the process of calibration. The SciCRT will work mainly as a Solar Neutron and Muon Telescope, it is designed to achieve: (1) larger effective area than the current Solar Neutron Telescope, (2) higher energy resolution to determine the energy spectrum of solar neutrons, (3) lower energy threshold, and (4) higher particle identification ability.« less
Palacios-Cabrera, Hector A; Menezes, Hilary C; Iamanaka, Beatriz T; Canepa, Frederico; Teixeira, Aldir A; Carvalhaes, Nelson; Santi, Domenico; Leme, Plinio T Z; Yotsuyanagi, Katumi; Taniwaki, Marta H
2007-01-01
Changes in temperature, relative humidity, and moisture content of green coffee beans were monitored during transportation of coffee from Brazil to Italy. Six containers (three conventional and three prototype) were stowed in three different places (hold, first floor, and deck) on the ship. Each prototype was located next to a conventional container. The moisture content of the coffee in the container located on the first floor was less affected by environmental variations (0.7%) than that in the hold and on the deck. Coffee located in the hold showed the highest variation in moisture content (3%); in addition, the container showed visible condensation. Coffee transported on the deck showed an intermediary variation in moisture (2%), and there was no visible condensation. The variation in coffee moisture content of the prototype containers was similar to that of the conventional ones, especially in the top layers of coffee bags (2 to 3%), while the increase in water activity was 0.70. This suggests that diffusion of moisture occurs very slowly inside the cargo and that there are thus sufficient time and conditions for fungal growth. The regions of the container near the wall and ceiling are susceptible to condensation since they are close to the headspace with its high relative humidity. Ochratoxin A production occurred in coffee located at the top of the container on the deck and in the wet bags from the hold (those found to be wet on opening the containers at the final destination).
Ortiz, E.; Valdés-Galicia, J. F.; Matsubara, Y.; ...
2016-02-16
In this study we report the flux of protons and neutral emission measured at the top of the Sierra Negra volcano at 4600 m.a.s.l. (575 g/cm 2), in Eastern Mexico. As an example of the capability of the mini-SciCR as a cosmic ray detector we present the Forbush decrease recorded on March 7, 2012. These data were obtained with a cosmic ray detector prototype called mini-SciCR that was operating from October 2010 to July 2012. Our main aims were to measure the hadronic component flux of the secondary cosmic ray and to show the appropriate performance of all system ofmore » the detector. To separate the signals of protons from other charged particles we obtained the energy deposition pattern when they cross the detector using a Monte Carlo simulation, and to separate the signals of neutral emission we used an anticoincidence system between the edge bars and the internal bars of the detector. The mini-SciCR is a prototype of a new cosmic ray detector called SciBar Cosmic Ray Telescope (SciCRT) installed in the same place, which is in the process of calibration. The SciCRT will work mainly as a Solar Neutron and Muon Telescope, it is designed to achieve: (1) larger effective area than the current Solar Neutron Telescope, (2) higher energy resolution to determine the energy spectrum of solar neutrons, (3) lower energy threshold, and (4) higher particle identification ability.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortiz, E.; Valdés-Galicia, J. F.; Matsubara, Y.
In this study we report the flux of protons and neutral emission measured at the top of the Sierra Negra volcano at 4600 m.a.s.l. (575 g/cm 2), in Eastern Mexico. As an example of the capability of the mini-SciCR as a cosmic ray detector we present the Forbush decrease recorded on March 7, 2012. These data were obtained with a cosmic ray detector prototype called mini-SciCR that was operating from October 2010 to July 2012. Our main aims were to measure the hadronic component flux of the secondary cosmic ray and to show the appropriate performance of all system ofmore » the detector. To separate the signals of protons from other charged particles we obtained the energy deposition pattern when they cross the detector using a Monte Carlo simulation, and to separate the signals of neutral emission we used an anticoincidence system between the edge bars and the internal bars of the detector. The mini-SciCR is a prototype of a new cosmic ray detector called SciBar Cosmic Ray Telescope (SciCRT) installed in the same place, which is in the process of calibration. The SciCRT will work mainly as a Solar Neutron and Muon Telescope, it is designed to achieve: (1) larger effective area than the current Solar Neutron Telescope, (2) higher energy resolution to determine the energy spectrum of solar neutrons, (3) lower energy threshold, and (4) higher particle identification ability.« less
Facility target insert shielding assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mocko, Michal
2015-10-06
Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In themore » present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.« less
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property....5005 Shop, bench, cupboard or site stock. Shop, bench, cupboard or site stocks are an accumulation of...
Nutrient Removal Benefits of Two-Stage Ditches
NASA Astrophysics Data System (ADS)
Liu, X.; Ward, A.
2016-12-01
Annually, about one-third of the corn and soybeans in the world is grown in the North Central Region of the United States. Water quality problems associated with these production systems are caused by: (1) discharges of dissolved reactive phosphorus into the Great Lakes and inland water bodies; and (2) discharges of nitrogen into the Gulf of Mexico. These discharges have caused large blue-green algal blooms in freshwater systems and hypoxia particularly in the Gulf of Mexico. Much of the region has poorly drained soils that necessitate the use of subsurface drainage system to make the fields farmable. These drains discharge into agricultural ditches that are usually 2-5 m deep and 10 to 20 m wide. These oversized ditches often form small grassed benches in their lower third. A common maintenance practice is to periodically cleanout these deposits. However, in the last 15 years a new practice has been developed by one of the co-authors. This practice does not disturb the lower portion of the ditch but widens the top portion to make the benches larger. This floodplain development practice is known as the two-stage ditch concept. The approach results in the ditches acting as intermittent linear wetlands. The practice is eligible for cost-sharing funding as a water quality Best Management Practice in Indiana and Ohio. This presentation will provide a summary of the research that has been conducted on two-stage ditches and in particular their nutrient removal potential. In addition, results of a new controlled study on the nitrogen and phosphorus removal performance of a two-stage ditch will be presented. This study introduced water with fixed concentrations of each nutrient into a two-stage ditch. Measurements were made of: (1) the retention time in the system; (2) changes in the surface water quality; (3) and changes in the water quality and water level elevations in nested piezometers and monitoring wells located in the benches and banks of the two-stage ditch.
Shoepe, Todd C; Ramirez, David A; Rovetti, Robert J; Kohler, David R; Almstedt, Hawley C
2011-09-01
The purpose of this investigation was to assess the effectiveness of variable resistance as provided through elastic plus free weight techniques in college aged males and females. Twenty novice lifters were randomly assigned to a traditional free weight only (6 males and 5 females) or elastic band plus free weight group (5 males and 5 females) and 9 more normally active controls (5 males and 4 females), were recruited to maintain normal activity for the duration of the study. No differences existed between control, free weight and elastic band at baseline for age, body height, body mass, body mass index, and body fat percentage. One-repetition maximums were performed for squat and bench press while both strength and power were assessed using isokinetic dynamometry. Elastic groups and free-weight groups completed 24 weeks of whole body, periodized, high intensity resistance (65-95% of one-repetition maximum) training three times/week. Training programs were identical except that the elastic group trained the barbell squat, bench press and stiff-legged deadlift with 20-35% of their total prescribed training loads coming from band resistance (assessed at the top of the range of motion) with the remainder from free weight resistance. A mixed-model analysis revealed that peak torque, average power and one-repetition maximums for squat were significantly greater after training for the elastic group compared to the control (p<0.05). In addition, the free weight group also showed significantly greater improvements over the control in peak torque and one-repetition maximums for squat and bench press. No significant differences were observed between the elastic band and free weight groups. Combined variable elastic band plus free weight exercises are effective at increasing strength and power similar to free-weights alone in novice college aged males and females. However, due to complexity in set-up and load assignment elastic adoption by novice lifters in an unsupervised situation is not advised.
Influence of bench angle on upper extremity muscular activation during bench press exercise.
Lauver, Jakob D; Cayot, Trent E; Scheuermann, Barry W
2016-01-01
This study compared the muscular activation of the pectoralis major, anterior deltoid and triceps brachii during a free-weight barbell bench press performed at 0°, 30°, 45° and -15° bench angles. Fourteen healthy resistance trained males (age 21.4 ± 0.4 years) participated in this study. One set of six repetitions for each bench press conditions at 65% one repetition maximum were performed. Surface electromyography (sEMG) was utilised to examine the muscular activation of the selected muscles during the eccentric and concentric phases. In addition, each phase was subdivided into 25% contraction durations, resulting in four separate time points for comparison between bench conditions. The sEMG of upper pectoralis displayed no difference during any of the bench conditions when examining the complete concentric contraction, however differences during 26-50% contraction duration were found for both the 30° [122.5 ± 10.1% maximal voluntary isometric contraction (MVIC)] and 45° (124 ± 9.1% MVIC) bench condition, resulting in greater sEMG compared to horizontal (98.2 ± 5.4% MVIC) and -15 (96.1 ± 5.5% MVIC). The sEMG of lower pectoralis was greater during -15° (100.4 ± 5.7% MVIC), 30° (86.6 ± 4.8% MVIC) and horizontal (100.1 ± 5.2% MVIC) bench conditions compared to the 45° (71.9 ± 4.5% MVIC) for the whole concentric contraction. The results of this study support the use of a horizontal bench to achieve muscular activation of both the upper and lower heads of the pectoralis. However, a bench incline angle of 30° or 45° resulted in greater muscular activation during certain time points, suggesting that it is important to consider how muscular activation is affected at various time points when selecting bench press exercises.
Using bench press load to predict upper body exercise loads in physically active individuals.
Wong, Del P; Ngo, Kwan-Lung; Tse, Michael A; Smith, Andrew W
2013-01-01
This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m(-2)) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p < 0.01). The bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p < 0.01). Linear regression revealed that the bench press load was a significant (R(2) range from 0.64 to 0.86, p < 0.01) predictor for the loads of the 4 assistance exercises. The following 6RM prediction equations were determined: (a) Hammer curl = Bench press load (0.28) + 6.30 kg, (b) Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key pointsThe bench press load was significantly correlated with the loads of the 4 assistance exercises.No significant differences were found between the actual load and the predicted load in the four equations.6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises.
Using Bench Press Load to Predict Upper Body Exercise Loads in Physically Active Individuals
Wong, Del P.; Ngo, Kwan-Lung; Tse, Michael A.; Smith, Andrew W.
2013-01-01
This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m-2) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p < 0.01). The bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p < 0.01). Linear regression revealed that the bench press load was a significant (R2 range from 0.64 to 0.86, p < 0.01) predictor for the loads of the 4 assistance exercises. The following 6RM prediction equations were determined: (a) Hammer curl = Bench press load (0.28) + 6.30 kg, (b) Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key points The bench press load was significantly correlated with the loads of the 4 assistance exercises. No significant differences were found between the actual load and the predicted load in the four equations. 6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises. PMID:24149723
Mercury in Eastern Kentucky coals: Geologic aspects and possible reduction strategies
Hower, J.C.; Eble, C.F.; Quick, J.C.
2005-01-01
Mercury emissions from US coal-fired power plants will be regulated by the US Environmental Protection Agency (USEPA) before the end of the decade. Because of this, the control of Hg in coal is important. Control is fundamentally based on the knowledge of the amounts of Hg in mined, beneficiated, and as-fired coal. Eastern Kentucky coals, on a reserve district level, have Hg contents similar to the USA average for coal at mines. Individual coals show greater variation at the bench scale, with Hg enrichment common in the top bench, often associated with enhanced levels of pyritic sulfur. Some of the variation between parts of eastern Kentucky is also based on the position relative to major faults. The Pine Mountain thrust fault appears to be responsible for elemental enrichment, including Hg, in coals on the footwall side of the thrust. Eastern Kentucky coals shipped to power plants in 1999, the year the USEPA requested coal quality information on coal deliveries, indicate that coals shipped from the region have 0.09 ppm Hg, compared to 0.10 ppm for all delivered coals in the USA. On an equal energy basis, and given equal concentrations of Hg, the high volatile bituminous coals from eastern Kentucky would emit less Hg than lower rank coals from other USA regions. ?? 2005 Elsevier B.V. All rights reserved.
Dose monitoring in Partial Liquid Ventilation by infrared measurement of expired perfluorochemicals.
Mazzoni, M; Nugent, L; Klein, D; Hoffman, J; Sekins, K M; Flaim, S F
1999-01-01
Patients undergoing Partial Liquid Ventilation (PLV) with the perfluorochemical liquid perflubron (PFB) continuously evaporate the drug from the lung during ventilatory expiration. In this study, two infrared (IR) devices, a modified industrial analyzer ("experimental prototype") and a custom-designed device suitable for use in a clinical environment ("clinical prototype"), were calibrated and validated on the bench to measure a range of PFB concentrations (CPFB) in a gas stream. PFB loss from the lung (area under the CPFB-vs-time-curve) could be correlated during PLV simulation with changes in tidal volume, breathing rate, and variable CPFB-vs-time profiles. The two IR devices produced nearly identical measurements for the same CPFB standards (maximum deviation = 1.5%). The experimental IR prototype was tested in 17 anesthetized, paralyzed, and ventilated swine (42-53 kg) to quantify the total amount and rate of evaporate loss of PFB over 12 hours of PLV, both with and without periodic supplemental PFB doses. The residual PFB volumes in the animal lungs at the end of the study, as determined by a gravimetric postmortem lung method, were found to agree on average for all animals to within 10% of the residual PFB volume as predicted by the IR approach. Furthermore, the IR signal of CPFB does not appear to correlate with the absolute amount of PFB in the lungs, but may reflect the relative proportion of PFB-wetted airway and alveolar surface. The authors conclude that IR quantitation of PFB evaporative loss is acceptably accurate for extended periods of PLV and may be a useful tool in the clinic for PFB dose monitoring and maintenance, thereby helping to optimize PLV treatment.
Development and Validation of an NPSS Model of a Small Turbojet Engine
NASA Astrophysics Data System (ADS)
Vannoy, Stephen Michael
Recent studies have shown that integrated gas turbine engine (GT)/solid oxide fuel cell (SOFC) systems for combined propulsion and power on aircraft offer a promising method for more efficient onboard electrical power generation. However, it appears that nobody has actually attempted to construct a hybrid GT/SOFC prototype for combined propulsion and electrical power generation. This thesis contributes to this ambition by developing an experimentally validated thermodynamic model of a small gas turbine (˜230 N thrust) platform for a bench-scale GT/SOFC system. The thermodynamic model is implemented in a NASA-developed software environment called Numerical Propulsion System Simulation (NPSS). An indoor test facility was constructed to measure the engine's performance parameters: thrust, air flow rate, fuel flow rate, engine speed (RPM), and all axial stage stagnation temperatures and pressures. The NPSS model predictions are compared to the measured performance parameters for steady state engine operation.
Towards a direct measurement of vacuum magnetic birefringence: PVLAS achievements
NASA Astrophysics Data System (ADS)
Della Valle, F.; Di Domenico, G.; Gastaldi, U.; Milotti, E.; Pengo, R.; Ruoso, G.; Zavattini, G.
2010-11-01
Nonlinear effects in vacuum have been predicted but never observed yet directly. The PVLAS collaboration has long been working on an apparatus aimed at detecting such effects by measuring vacuum magnetic birefringence. Unfortunately the sensitivity has been affected by unaccounted noise and systematics since the beginning. A new small prototype ellipsometer has been designed and characterized at the Department of Physics of the University of Ferrara, Italy entirely mounted on a single seismically isolated optical bench. With a finesse F = 414,000 and a cavity length L = 0.5 m we have reached the sensitivity of ψ=2ṡ101/√{Hz} given the laser power at the output of the ellipsometer of P = 24 mW. This record result, very close to the predicted limit, demonstrates the feasibility of reaching such sensitivities, and opens the way to designing a dedicated apparatus for a first detection of vacuum magnetic birefringence.
An Optical Sensor for Measuring the Position and Slanting Direction of Flat Surfaces
Chen, Yu-Ta; Huang, Yen-Sheng; Liu, Chien-Sheng
2016-01-01
Automated optical inspection is a very important technique. For this reason, this study proposes an optical non-contact slanting surface measuring system. The essential features of the measurement system are obtained through simulations using the optical design software Zemax. The actual propagation of laser beams within the measurement system is traced by using a homogeneous transformation matrix (HTM), the skew-ray tracing method, and a first-order Taylor series expansion. Additionally, a complete mathematical model that describes the variations in light spots on photoelectric sensors and the corresponding changes in the sample orientation and distance was established. Finally, a laboratory prototype system was constructed on an optical bench to verify experimentally the proposed system. This measurement system can simultaneously detect the slanting angles (x, z) in the x and z directions of the sample and the distance (y) between the biconvex lens and the flat sample surface. PMID:27409619
An Optical Sensor for Measuring the Position and Slanting Direction of Flat Surfaces.
Chen, Yu-Ta; Huang, Yen-Sheng; Liu, Chien-Sheng
2016-07-09
Automated optical inspection is a very important technique. For this reason, this study proposes an optical non-contact slanting surface measuring system. The essential features of the measurement system are obtained through simulations using the optical design software Zemax. The actual propagation of laser beams within the measurement system is traced by using a homogeneous transformation matrix (HTM), the skew-ray tracing method, and a first-order Taylor series expansion. Additionally, a complete mathematical model that describes the variations in light spots on photoelectric sensors and the corresponding changes in the sample orientation and distance was established. Finally, a laboratory prototype system was constructed on an optical bench to verify experimentally the proposed system. This measurement system can simultaneously detect the slanting angles (x, z) in the x and z directions of the sample and the distance (y) between the biconvex lens and the flat sample surface.
20000G shock energy harvesters for gun-fired munition
NASA Astrophysics Data System (ADS)
Willemin, J.; Boisseau, S.; Olmos, L.; Gallardo, M.; Despesse, G.; Robert, T.
2016-11-01
This paper presents a 20000G shock energy harvester dedicated to gun-fired munitions and based on a mass-spring resonant structure coupled to a coil-magnet electromagnetic converter. The 20000G shock energy is firstly stored in the spring as elastic potential energy, released as mass-spring mechanical oscillations right after the shock and finally converted into electricity thanks to the coil-magnet transducer. The device has been modeled, sized to generate 200mJ in 150ms, manufactured and tested in a gun-fired munition. The prototype sizes 117cm3 and weighs 370g. 210mJ have been generated in a test bench and 140mJ in real conditions; this corresponds to a mean output power of 0.93W (7.9mW/cm3) and a maximum output power of 4.83W (41.3mW/cm3) right after the shock.
Hygrothermal properties of composites
NASA Technical Reports Server (NTRS)
Arsenovic, Petar
1996-01-01
The testing procedure and acceptance criteria for outgassing selection of materials to be used in spacecraft has been reviewed. Outgassing testing should be conducted according to ASTM Standard E 595-90. In general, materials with CVCM less than or equal to 0.10% and TML less than or equal to 1.00% are acceptable for space applications. Next, test data on several types of graphite-epoxy composite materials are presented over time at various relative humidity levels at room temperature for moisture absorption, and under vacuum at several temperatures for moisture desorption (outgassing). The data can be accurately represented by simple equations which are useful for materials characterization. Finally, a laser dilatometer systems of extremely high sensitivity and accuracy was assembled and used to measure the coefficient of thermal expansion (CTE) of several types of graphite-epoxy structures, culminating in the ability to perform loading and thermal expansion tests on a prototype optical bench.
Olivier, Serge; Delage, Laurent; Reynaud, Francois; Collomb, Virginie; Trouillon, Michel; Grelin, Jerome; Schanen, Isabelle; Minier, Vincent; Broquin, Jean-Emmanuel; Ruilier, Cyril; Leone, Bruno
2007-02-20
We present a three-telescope space-based interferometer prototype dedicated to high-resolution imaging. This project, named multiaperture fiber-linked interferometer (MAFL), was founded by the European Space Agency. The aim of the MAFL project is to propose, design, and implement for the first time to the best of our knowledge all the optical functions required for the global instrument on the same integrated optics (IO) component for controlling a three-arm interferometer and to obtain reliable science data. The coherent transport from telescopes to the IO component is achieved by means of highly birefringent optical fiber. The laboratory bench is presented, and the results are reported allowing us to validate the optical potentiality of the IO component in this frame. The validation measurements consist of the throughput of this optical device, the performances of metrological servoloop, and the instrumental contrasts and phase closure of the science fringes.
Nam, Kanghyun; Cho, Kwanghyun; Park, Sang-Shin; Choi, Seibum B.
2017-01-01
This paper details the new design and dynamic simulation of an electro-hydraulic camless engine valve actuator (EH-CEVA) and experimental verification with lift position sensors. In general, camless engine technologies have been known for improving fuel efficiency, enhancing power output, and reducing emissions of internal combustion engines. Electro-hydraulic valve actuators are used to eliminate the camshaft of an existing internal combustion engines and used to control the valve timing and valve duration independently. This paper presents novel electro-hydraulic actuator design, dynamic simulations, and analysis based on design specifications required to satisfy the operation performances. An EH-CEVA has initially been designed and modeled by means of a powerful hydraulic simulation software, AMESim, which is useful for the dynamic simulations and analysis of hydraulic systems. Fundamental functions and performances of the EH-CEVA have been validated through comparisons with experimental results obtained in a prototype test bench. PMID:29258270
A balloon-borne prototype for demonstrating the concept of JEM-EUSO
NASA Astrophysics Data System (ADS)
von Ballmoos, P.; Santangelo, A.; Adams, J. H.; Barrillon, P.; Bayer, J.; Bertaina, M.; Cafagna, F.; Casolino, M.; Dagoret, S.; Danto, P.; Distratis, G.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Evrard, J.; Gorodetzky, Ph.; Haungs, A.; Jung, A.; Kawasaki, Y.; Medina-Tanco, G.; Mot, B.; Osteria, G.; Parizot, E.; Park, I. H.; Picozza, P.; Prévôt, G.; Prieto, H.; Ricci, M.; Rodríguez Frías, M. D.; Roudil, G.; Scotti, V.; Szabelski, J.; Takizawa, Y.; Tusno, K.
2014-05-01
EUSO-BALLOON has been conceived as a pathfinder for JEM-EUSO, a mission concept for a space-borne wide-field telescope monitoring the Earth's nighttime atmosphere with the objective of recording the ultraviolet light from tracks initiated by ultra-high energy cosmic rays. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-BALLOON will serve as a test-bench for the key technologies of JEM-EUSO. EUSO-BALLOON shall perform an end-to-end test of all subsystems and components, and prove the global detection chain while improving our knowledge of the atmospheric and terrestrial ultraviolet background. The balloon-instrument also has the potential to detect for the first time UV-light generated by atmospheric air-shower from above, marking a milestone in the development of UHECR science, and paving the way for any future large scale, space-based ultra-high energy cosmic ray observatory.
In Vitro Hydrodynamic Assessment of a New Transcatheter Heart Valve Concept (the TRISKELE).
Rahmani, Benyamin; Tzamtzis, Spyros; Sheridan, Rose; Mullen, Michael J; Yap, John; Seifalian, Alexander M; Burriesci, Gaetano
2017-04-01
This study presents the in vitro hydrodynamic assessment of the TRISKELE, a new system suitable for transcatheter aortic valve implantation (TAVI), aiming to mitigate the procedural challenges experienced with current technologies. The TRISKELE valve comprises three polymeric leaflet and an adaptive sealing cuff, supported by a novel fully retrievable self-expanding nitinol wire frame. Valve prototypes were manufactured in three sizes of 23, 26, and 29 mm by automated dip-coating of a biostable polymer, and tested in a hydrodynamic bench setup in mock aortic roots of 21, 23, 25, and 27 mm annulus, and compared to two reference valves suitable for equivalent implantation ranges: Edwards SAPIEN XT and Medtronic CoreValve. The TRISKELE valves demonstrated a global hydrodynamic performance comparable or superior to the controls with significant reduction in paravalvular leakage. The TRISKELE valve exhibits enhanced anchoring and improved sealing. The valve is currently under preclinical investigation.
Nam, Kanghyun; Cho, Kwanghyun; Park, Sang-Shin; Choi, Seibum B
2017-12-18
This paper details the new design and dynamic simulation of an electro-hydraulic camless engine valve actuator (EH-CEVA) and experimental verification with lift position sensors. In general, camless engine technologies have been known for improving fuel efficiency, enhancing power output, and reducing emissions of internal combustion engines. Electro-hydraulic valve actuators are used to eliminate the camshaft of an existing internal combustion engines and used to control the valve timing and valve duration independently. This paper presents novel electro-hydraulic actuator design, dynamic simulations, and analysis based on design specifications required to satisfy the operation performances. An EH-CEVA has initially been designed and modeled by means of a powerful hydraulic simulation software, AMESim, which is useful for the dynamic simulations and analysis of hydraulic systems. Fundamental functions and performances of the EH-CEVA have been validated through comparisons with experimental results obtained in a prototype test bench.
Status of the ion sources developments for the Spiral2 project at GANILa)
NASA Astrophysics Data System (ADS)
Lehérissier, P.; Bajeat, O.; Barué, C.; Canet, C.; Dubois, M.; Dupuis, M.; Flambard, J. L.; Frigot, R.; Jardin, P.; Leboucher, C.; Lemagnen, F.; Maunoury, L.; Osmond, B.; Pacquet, J. Y.; Pichard, A.; Thuillier, T.; Peaucelle, C.
2012-02-01
The SPIRAL 2 facility is now under construction and will deliver either stable or radioactive ion beams. First tests of nickel beam production have been performed at GANIL with a new version of the large capacity oven, and a calcium beam has been produced on the heavy ion low energy beam transport line of SPIRAL 2, installed at LPSC Grenoble. For the production of radioactive beams, several target/ion-source systems (TISSs) are under development at GANIL as the 2.45 GHz electron cyclotron resonance ion source, the surface ionization source, and the oven prototype for heating the uranium carbide target up to 2000 °C. The existing test bench has been upgraded for these developments and a new one, dedicated for the validation of the TISS before mounting in the production module, is under design. Results and current status of these activities are presented.
Human topoisomerase I poisoning: docking protoberberines into a structure-based binding site model
NASA Astrophysics Data System (ADS)
Kettmann, Viktor; Košt'álová, Daniela; Höltje, Hans-Dieter
2004-12-01
Using the X-ray crystal structure of the human topoisomerase I (top1) - DNA cleavable complex and the Sybyl software package, we have developed a general model for the ternary cleavable complex formed with four protoberberine alkaloids differing in the substitution on the terminal phenyl rings and covering a broad range of the top1-poisoning activities. This model has the drug intercalated with its planar chromophore between the -1 and +1 base pairs flanking the cleavage site, with the nonplanar portion pointing into the minor groove. The ternary complexes were geometry-optimized and relative interaction energies, computed by using the Tripos force field, were found to rank in correct order the biological potency of the compounds; in addition, the model is also consistent with the top1-poisoning inactivity of berberine, a major prototype of the protoberberine alkaloids. The model might serve as a rational basis for elaboration of the most active compound as a lead structure, in order to develop more potent top1 poisons as next generation anti-cancer drugs.
Rogers, Benjamin H; Brown, Justin C; Gater, David R; Schmitz, Kathryn H
2017-02-01
To characterize the relationship between 1-repetition maximum (1-RM) bench press strength and isometric handgrip strength among breast cancer survivors. Cross-sectional study. Laboratory. Community-dwelling breast cancer survivors (N=295). Not applicable. 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer, with 3 maximal contractions of the left and right hands. All measures were conducted by staff with training in clinical exercise testing. Among 295 breast cancer survivors, 1-RM bench press strength was 18.2±6.1kg (range, 2.2-43.0kg), and isometric handgrip strength was 23.5±5.8kg (range, 9.0-43.0kg). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=.399; P<.0001). Mean difference analysis suggested that the average isometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7kg (95% limits of agreement, -8.2 to 17.6kg). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=.31; P<.0001) and age (β=-.20; P<.0001) were positively correlated with 1-RM bench press strength (R 2 =.23). Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among breast cancer survivors. 1-RM bench press strength and isometric handgrip strength quantify distinct components of muscular strength. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Denadai, Rafael; Oshiiwa, Marie; Saad-Hossne, Rogério
2014-03-01
The search for alternative and effective forms of training simulation is needed due to ethical and medico-legal aspects involved in training surgical skills on living patients, human cadavers and living animals. To evaluate if the bench model fidelity interferes in the acquisition of elliptical excision skills by novice medical students. Forty novice medical students were randomly assigned to 5 practice conditions with instructor-directed elliptical excision skills' training (n = 8): didactic materials (control); organic bench model (low-fidelity); ethylene-vinyl acetate bench model (low-fidelity); chicken legs' skin bench model (high-fidelity); or pig foot skin bench model (high-fidelity). Pre- and post-tests were applied. Global rating scale, effect size, and self-perceived confidence based on Likert scale were used to evaluate all elliptical excision performances. The analysis showed that after training, the students practicing on bench models had better performance based on Global rating scale (all P < 0.0000) and felt more confident to perform elliptical excision skills (all P < 0.0000) when compared to the control. There was no significant difference (all P > 0.05) between the groups that trained on bench models. The magnitude of the effect (basic cutaneous surgery skills' training) was considered large (>0.80) in all measurements. The acquisition of elliptical excision skills after instructor-directed training on low-fidelity bench models was similar to the training on high-fidelity bench models; and there was a more substantial increase in elliptical excision performances of students that trained on all simulators compared to the learning on didactic materials.
Optical Bench for LISA-like missions
NASA Astrophysics Data System (ADS)
Mueller, Guido
The detection of B-modes in the μ-Wave background has rattled the scientific community and further enhanced the large scientific interest in gravitational waves and gravitational wave astronomy. The first direct detection of gravitational waves by Advanced LIGO and maybe also by pulsar timing arrays in the second half of this decade will be another watershed event which will start a new era in astronomy and astrophysics. However, the holy grail of gravitational wave astronomy will be opened by a LISA-like mission. Only space provides the environment that allows to cover the signal-rich mHz frequency range where we expect to see gravitational waves from massive black hole mergers, compact galactic binaries, and many other sources. All mature concepts use laser interferometry between free falling test masses separated by millions of km. The central piece in all these concepts is a stable optical bench which is used to prepare and exchange the laser beams between the different arms. It has always been assumed that the base material for the optical bench has to be one of the ultra-low expansion glasses such as Zerodur or ULE to meet the pm/#Hz stability requirements. This very conservative approach was a reflection of the state-of-the-art in frequency stabilization experiments which used optical reference cavities in the early ‘90s. It is not surprising that the LISA pathfinder (LPF) uses also an all Zerodur bench where each optical component is precision bonded to the bench using hydroxide bonding, a nonreversible bonding technique. The manufacturing of this bench was a very time consuming one-mirror-a-day effort and was one of the highest risk items in terms of schedule and cost. The original LISA design uses the same approach except that the LISA bench is far more complex than the LPF bench and manufacturing of the required 10+ benches, six flight units and at least four pre-flight models and spares, will be even more time consuming and expensive. We question the need for ultra-low expansion glass for the optical bench. We will streamline the design of the bench and explore other materials and assembly techniques to significantly simplify the manufacturing process. Why are we confident that this is possible? One argument is that in early LISA designs the reference cavity was also part of the bench. This cavity drove the requirements to 30 fm/#Hz, a factor 30 more stringent compared to the current requirements. Since the cavity has now been removed from the bench, the requirements have been relaxed. A second argument is that we demonstrated pm/#Hz performance for a number of different materials and structures which are all candidate materials for the telescopes which also have to meet the same requirements over actually a larger distance. Our objective is to take a fresh look at the optical bench. We will redesign core parts of the interferometer bench with a focus on reducing the number and lengths of critical paths and moving non-critical parts away from the core part of the bench and sometimes even into optical fibers. We also propose to use different materials and assembly techniques for the optical bench and strongly believe that they will still meet the pm/#Hz requirement and will also be stable on long time scales. This confidence is based on nearly ten years of experience during which we investigated different materials and structures for the telescopes which we plan to apply now to the optical bench.
An ultra stable optical bench for the magnetic survey satellite
NASA Technical Reports Server (NTRS)
Wingate, C. A., Jr.; Coughlin, T. B.; Sullivan, R. M.
1978-01-01
The Magsat optical bench has been designed and built to hold the alignment of five optical elements to deflections of 1-2 arcsec during orbital operation. The bench has been designed to withstand alignment changes during the launch and prestabilization phases of the mission. Severe weight constraints, in conjunction with the thermal and structural requirements, led to the choice of graphite-fiber-reinforced epoxy egg crate core and face sheets for the bench construction. Active temperature control was necessary to meet thermal deflection objectives, and novel kinematic mountings were required to prevent spacecraft bending from deflecting the bench.
Characterizing Scintillation and Cherenkov Light in Water-Based Liquid Scintillators
NASA Astrophysics Data System (ADS)
Land, Benjamin; Caravaca, Javier; Descamps, Freija; Orebi Gann, Gabriel
2016-09-01
The recent development of Water-based Liquid Scintillator (WbLS) has made it possible to produce scintillating materials with highly tunable light yields and excellent optical clarity. This allows for a straightforward combination of the directional properties of Cherenkov light with the greater energy resolution afforded by the typically brighter scintillation light which lends itself well to a broad program of neutrino physics. Here we explore the light yields and time profiles of WbLS materials in development for Theia (formerly ASDC) as measured in CheSS: our bench-top Cherenkov and scintillation separation R&D project at Berkeley Lab. This work was supported by the Laboratory Directed Research and Development Program of Lawrence Berkeley National Laboratory under U.S. Department of Energy Contract No. DE-AC02-05CH11231.
A new method for using Cf-252 in SEU testing
NASA Astrophysics Data System (ADS)
Costantine, A.; Howard, J. W.; Becker, M.; Block, R. C.; Smith, L. S.; Soli, G. A.; Stauber, M. C.
1990-12-01
A system using Cf-252 and associated nuclear instrumentation has determined the single-event upset (SEU) cross section versus linear energy transfer (LET) curve for several 2K x 8 static random access memories (SRAMs). The Cf-252 fission fragments pass through a thin-film organic scintillator detector (TFD) on the way to the device under test (DUT). The TFD provides energy information for each transiting fragment. Data analysis provides the energy of the individual ion responsible for each SEU; thus, separate upset cross sections can be developed for different energy and mass regions of the californium spectrum. This californium-based device is quite small and fits onto a bench top. It provides a convenient and inexpensive supplement or alternative to accelerator and high-altitude/space SEU testing.
Fluidic Manufacture of Star-Shaped Gold Nanoparticles.
Silvestri, Alessandro; Lay, Luigi; Psaro, Rinaldo; Polito, Laura; Evangelisti, Claudio
2017-07-21
Star-shaped gold nanoparticles (StarAuNPs) are extremely attractive nanomaterials, characterized by localized surface plasmon resonance which could be potentially employed in a large number of applications. However, the lack of a reliable and reproducible synthetic protocols for the production of StarAuNPs is the major limitation to their spreading. For the first time, here we present a robust protocol to manufacture reproducible StarAuNPs by exploiting a fluidic approach. Star-shaped AuNPs have been synthesized by means of a seed-less protocol, employing ascorbic acid as reducing agent at room temperature. Moreover, the versatility of the bench-top microfluidic protocol has been exploited to afford hydrophilic, hydrophobic and solid-supported engineered StarAuNPs, by avoiding intermediate NP purifications. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cost-effective and Rapid Blood Analysis on a Cell-phone
Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan
2013-01-01
We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings. PMID:23392286
Cost-effective and rapid blood analysis on a cell-phone.
Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan
2013-04-07
We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.
Kim, MyeongHyeon; Kim, Hyunchang; Gweon, Dae-Gab
2012-10-01
This paper describes the design, modeling, optimization, and validation of an active vibration isolation system using a voice coil motor. The active vibration isolating method was constructed with a passive isolator and an active isolator. A spring was used for passive isolating; an actuator was used for active isolating. The proposed active vibration isolation system (AVIS) can isolate disturbances for many kinds of instruments. Until now, developed AVIS were able to isolate a six degree-of-freedom disturbance effectively. This paper proposes the realization of such a six degree-of-freedom active vibration isolation system that can work as a bench top device for precision measuring machines such as atomic force microscope, scanning probe microscope, etc.
Portable gas chromatograph-mass spectrometer
Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.
1996-06-11
A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.
Correlation of Predicted and Observed Optical Properties of Multilayer Thermal Control Coatings
NASA Technical Reports Server (NTRS)
Jaworske, Donald A.
1998-01-01
Thermal control coatings on spacecraft will be increasingly important, as spacecraft grow smaller and more compact. New thermal control coatings will be needed to meet the demanding requirements of next generation spacecraft. Computer programs are now available to design optical coatings and one such program was used to design several thermal control coatings consisting of alternating layers of WO3 and SiO2. The coatings were subsequently manufactured with electron beam evaporation and characterized with both optical and thermal techniques. Optical data were collected in both the visible region of the spectrum and the infrared. Predictions of solar absorptance and infrared emittance were successfully correlated to the observed thermal control properties. Functional performance of the coatings was verified in a bench top thermal vacuum chamber.
Integrated photonics for infrared spectroscopic sensing
NASA Astrophysics Data System (ADS)
Lin, Hongtao; Kita, Derek; Han, Zhaohong; Su, Peter; Agarwal, Anu; Yadav, Anupama; Richardson, Kathleen; Gu, Tian; Hu, Juejun
2017-05-01
Infrared (IR) spectroscopy is widely recognized as a gold standard technique for chemical analysis. Traditional IR spectroscopy relies on fragile bench-top instruments located in dedicated laboratory settings, and is thus not suitable for emerging field-deployed applications such as in-line industrial process control, environmental monitoring, and point-ofcare diagnosis. Recent strides in photonic integration technologies provide a promising route towards enabling miniaturized, rugged platforms for IR spectroscopic analysis. Chalcogenide glasses, the amorphous compounds containing S, Se or Te, have stand out as a promising material for infrared photonic integration given their broadband infrared transparency and compatibility with silicon photonic integration. In this paper, we discuss our recent work exploring integrated chalcogenide glass based photonic devices for IR spectroscopic chemical analysis, including on-chip cavityenhanced chemical sensing and monolithic integration of mid-IR waveguides with photodetectors.
The potential and prospects of proximal remote sensing of arthropod pests.
Nansen, Christian
2016-04-01
Bench-top or proximal remote sensing applications are widely used as part of quality control and machine vision systems in commercial operations. In addition, these technologies are becoming increasingly important in insect systematics and studies of insect physiology and pest management. This paper provides a review and discussion of how proximal remote sensing may contribute valuable quantitative information regarding identification of species, assessment of insect responses to insecticides, insect host responses to parasitoids and performance of biological control agents. The future role of proximal remote sensing is discussed as an exciting path for novel paths of multidisciplinary research among entomologists and scientists from a wide range of other disciplines, including image processing engineers, medical engineers, research pharmacists and computer scientists. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
A new method for using Cf-252 in SEU testing
NASA Technical Reports Server (NTRS)
Costantine, A.; Howard, J. W.; Becker, M.; Block, R. C.; Smith, L. S.; Soli, G. A.; Stauber, M. C.
1990-01-01
A system using Cf-252 and associated nuclear instrumentation has determined the single-event upset (SEU) cross section versus linear energy transfer (LET) curve for several 2K x 8 static random access memories (SRAMs). The Cf-252 fission fragments pass through a thin-film organic scintillator detector (TFD) on the way to the device under test (DUT). The TFD provides energy information for each transiting fragment. Data analysis provides the energy of the individual ion responsible for each SEU; thus, separate upset cross sections can be developed for different energy and mass regions of the californium spectrum. This californium-based device is quite small and fits onto a bench top. It provides a convenient and inexpensive supplement or alternative to accelerator and high-altitude/space SEU testing.
NASA Astrophysics Data System (ADS)
Pitcher, Craig; Gao, Yang
2017-03-01
The dual-reciprocating drill (DRD) is a biologically-inspired low-mass alternative to traditional drilling techniques, using backwards-facing teethed halves to grip the surrounding substrate, generating a traction force that reduces the required overhead penetration force. Previous experiments using a proof-of-concept test bench have provided evidence as to the significant role of sideways movements and lateral forces in improving drilling performance. The system is also progressing to a first system prototype concept, in which an actuation mechanism is integrated within the drill heads. To experimentally determine the effect of lateral motions, a new internal actuation mechanism was developed to allow the inclusion of controlled sideways movements, resulting in the creation of the circular and diagonal burrowing motions. This paper presents an investigation into the performance of the reciprocation and burrowing motions by testing them in a planetary regolith simulant. Analysis of force sensor measurements has shown a relationship between the penetration and traction forces and the internal friction of the mechanism and depth achieved. These tests have also experimentally demonstrated the benefit of lateral motions in drilling performance, with both the burrowing mechanisms and drilling tests performed at an angle able to penetrate further than traditional vertical reciprocation, leading to the proposition of new burrowing and diagonal drilling mechanics. From this, a new fully integrated system prototype can be developed which incorporates lateral motions that can optimise the drilling performance.
NASA Astrophysics Data System (ADS)
Kazemiroodsari, Hadi
Liquefaction is loss of shear strength in fully saturated loose sands caused by build-up of excess pore water pressure, during moderate to large earthquakes, leading to catastrophic failures of structures. Currently used liquefaction mitigation measures are often costly and cannot be applied at sites with existing structures. An innovative, practical, and cost effective liquefaction mitigation technique titled "Induced Partial Saturation" (IPS) was developed by researchers at Northeastern University. The IPS technique is based on injection of sodium percarbonate solution into fully saturated liquefaction susceptible sand. Sodium percarbonate dissolves in water and breaks down into sodium and carbonate ions and hydrogen peroxide which generates oxygen gas bubbles. Oxygen gas bubbles become trapped in sand pores and therefore decrease the degree of saturation of the sand, increase the compressibility of the soil, thus reduce its potential for liquefaction. The implementation of IPS required the development and validation of a monitoring and evaluation technique that would help ensure that the sands are indeed partially saturated. This dissertation focuses on this aspect of the IPS research. The monitoring system developed was based on using electric conductivity fundamentals and probes to detect the transport of chemical solution, calculate degree of saturation of sand, and determine the final zone of partial saturation created by IPS. To understand the fundamentals of electric conductivity, laboratory bench-top tests were conducted using electric conductivity probes and small specimens of Ottawa sand. Bench-top tests were used to study rate of generation of gas bubbles due to reaction of sodium percarbonate solution in sand, and to confirm a theory based on which degree of saturation were calculated. In addition to bench-top tests, electric conductivity probes were used in a relatively large sand specimen prepared in a specially manufactured glass tank. IPS was implemented in the prepared specimen to validate the numerical simulation model and explore the use of conductivity probes to detect the transport of chemical solution, estimate degree of saturation achieved due to injection of chemical solution, and evaluate final zone of partial saturation. The conductivity probe and the simulation results agreed well. To study the effect of IPS on liquefaction response of the sand specimen, IPS was implemented in a large (2-story high) sand specimen prepared in the laminar box of NEES Buffalo and then the specimen was subjected to harmonic shaking. Electric conductivity probes were used in the specimen treatment by controlling the duration and spacing of injection of the chemical solution, in monitoring the transport of chemical solution, in the estimation of zone of partial saturation achieved, and in the estimation of degree of saturation achieved due to implementation of IPS. The conductivity probes indicated partial saturation of the specimen. The shaking tests results confirmed the partial saturation state of the sand specimen. In addition, to the laboratory works, electric conductivity probes were used in field implementation of IPS in a pilot test at the Wildlife Liquefaction Array (WLA) of NEES UCSB site. The conductivity probes in the field test helped decide the optimum injection pressure, the injection tube spacing, and the degree of saturation that could be achieved in the field. The various laboratory and field tests confirmed that electric conductivity and the probes devised and used can be invaluable in the implementation of IPS, by providing information regarding transport of the chemical solution, the spacing of injection tubes, duration of injection, and the zone and degree of partial saturation caused by IPS.
Ghigiarelli, Jamie J; Pelton, Luke M; Gonzalez, Adam M; Fulop, Andras M; Gee, Joshua Y; Sell, Katie M
2018-04-01
Ghigiarelli, JJ, Pelton, LM, Gonzalez, AM, Fulop, AM, Gee, JY, and Sell, KM. Effects of a 6-week bench press program using the freak bar in a sample of collegiate club powerlifters. J Strength Cond Res 32(4): 938-949, 2018-Powerlifters train using specialty bars for unstable load (UL) training. For the bench press, the acute effects of UL are mixed, with few studies that examine training interventions. The purpose of this study was to examine the effects of a 6-week bench press training program that uses the Freak Bar (FB) as compared to a traditional barbell (TB) on maximum bench press, peak force, and peak impulse. Seven men and 3 women (21 ± 2.0 years, 172.2 ± 2.9 cm, and 95.3 ± 20.3 kg) were required to bench press 2 days per week as part of a structured program. On the second bench press day, the FB and TB groups performed 3-position pause bench presses at 60-70% one repetition maximum (1RM). One repetition maximum, peak force, and peak impulse were measured before test and after test after the 6-week program. Peak force and peak impulse were tested at 3 bench positions, including the presticking, sticking, and poststicking points, defined by the distance of the barbell from the chest. Posttraining 1RM for the FB group and TB group increased 6.7% (6.78 ± 1.6 kg, p = 0.006) and 4.3% (4.5 ± 2.7 kg, p = 0.23), respectively, with no significant differences between the groups (p = 0.589, ηp = 0.044). There were no significant differences between the groups at each bench position for peak force (p = 0.606) or peak impulse (p = 0.542). Freak Bar can be an alternative for improving maximum strength and peak force but is not significantly better than TB training when performing the 3-position pause bench press.
Denadai, Rafael; Oshiiwa, Marie; Saad-Hossne, Rogério
2014-01-01
Background: The search for alternative and effective forms of training simulation is needed due to ethical and medico-legal aspects involved in training surgical skills on living patients, human cadavers and living animals. Aims: To evaluate if the bench model fidelity interferes in the acquisition of elliptical excision skills by novice medical students. Materials and Methods: Forty novice medical students were randomly assigned to 5 practice conditions with instructor-directed elliptical excision skills’ training (n = 8): didactic materials (control); organic bench model (low-fidelity); ethylene-vinyl acetate bench model (low-fidelity); chicken legs’ skin bench model (high-fidelity); or pig foot skin bench model (high-fidelity). Pre- and post-tests were applied. Global rating scale, effect size, and self-perceived confidence based on Likert scale were used to evaluate all elliptical excision performances. Results: The analysis showed that after training, the students practicing on bench models had better performance based on Global rating scale (all P < 0.0000) and felt more confident to perform elliptical excision skills (all P < 0.0000) when compared to the control. There was no significant difference (all P > 0.05) between the groups that trained on bench models. The magnitude of the effect (basic cutaneous surgery skills’ training) was considered large (>0.80) in all measurements. Conclusion: The acquisition of elliptical excision skills after instructor-directed training on low-fidelity bench models was similar to the training on high-fidelity bench models; and there was a more substantial increase in elliptical excision performances of students that trained on all simulators compared to the learning on didactic materials. PMID:24700937
NASA Astrophysics Data System (ADS)
Macedo, Milton P.; Correia, C. M. B. A.
2013-04-01
This work aims at showing the applicability of a scanning-stage bench-microscope in bright-field reflection mode for wirebonding inspection of integrated circuits (IC) as well as quality assurance of tracks in printed circuit boards (PCB). The main issues of our laboratorial prototype arise from the use of a linear image sensor taking advantage of its geometry to achieve lower acquisition time in comparison to traditional (pinhole) confocal approach. The use of a slit-detector is normally related to resolution degradation for details parallel to sensor. But an improvement will surely arise using light distribution along line pixels of the sensor which establishes a great advantage in comparison to (pure) slit detectors. The versatility of this bench-microscope affords excellent means to develop and test algorithms. Those to improve lateral resolution isotropy as well as image visualization and 3D mesh reconstruction under different setups namely illumination modes. Based on the results of these tests tests both wide-field illumination and parallel slit illumination and detection configurations were used in these two applications. Results from IC wire-bonding show the ability of the system to extract 3D information. A comparison of auto-focus images and 3D profiles obtained using different 3D reconstruction algorithms as well as a method for the determination of the diameter of the bond wire are presented. Measurements of PCB track width and thickness were performed and the comparison of these results from both longitudinal and transverse tracks stress the limitations of a lower spatial sampling rate induced by the resolution of object stage positioners.
SBIR Phase II Final Report: Low cost Autonomous NMR and Multi-sensor Soil Monitoring Instrument
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walsh, David O.
In this 32-month SBIR Phase 2 program, Vista Clara designed, assembled and successfully tested four new NMR instruments for soil moisture measurement and monitoring: An enhanced performance man-portable Dart NMR logging probe and control unit for rapid, mobile measurement in core holes and 2” PVC access wells; A prototype 4-level Dart NMR monitoring probe and prototype multi-sensor soil monitoring control unit for long-term unattended monitoring of soil moisture and other measurements in-situ; A non-invasive 1m x 1m Discus NMR soil moisture sensor with surface based magnet/coil array for rapid measurement of soil moisture in the top 50 cm of themore » subsurface; A non-invasive, ultra-lightweight Earth’s field surface NMR instrument for non-invasive measurement and mapping of soil moisture in the top 3 meters of the subsurface. The Phase 2 research and development achieved most, but not all of our technical objectives. The single-coil Dart in-situ sensor and control unit were fully developed, demonstrated and successfully commercialized within the Phase 2 period of performance. The multi-level version of the Dart probe was designed, assembled and demonstrated in Phase 2, but its final assembly and testing were delayed until close to the end of the Phase 2 performance period, which limited our opportunities for demonstration in field settings. Likewise, the multi-sensor version of the Dart control unit was designed and assembled, but not in time for it to be deployed for any long-term monitoring demonstrations. The prototype ultra-lightweight surface NMR instrument was developed and demonstrated, and this result will be carried forward into the development of a new flexible surface NMR instrument and commercial product in 2018.« less
Direction-specific recruitment of rotator cuff muscles during bench press and row.
Wattanaprakornkul, Duangjai; Halaki, Mark; Cathers, Ian; Ginn, Karen A
2011-12-01
Recent studies indicate that rotator cuff (RC) muscles are recruited in a reciprocal, direction-specific pattern during shoulder flexion and extension exercises. The main purpose of this study was to determine if similar reciprocal RC recruitment occurs during bench press (flexion-like) and row (extension-like) exercises. In addition, shoulder muscle activity was comprehensively compared between bench press and flexion; row and extension; and bench press and row exercises. Electromyographic (EMG) activity was recorded from 9 shoulder muscles sites in 15 normal volunteers. All exercises were performed at 20, 50 and 70% of subjects' maximal load. EMG data were normalized to standard maximal voluntary contractions. Infraspinatus activity was significantly higher than subscapularis during bench press, with the converse pattern during the row exercise. Significant differences in activity levels were found in pectoralis major, deltoid and trapezius between the bench press and flexion exercises and in lower trapezius between the row and extension exercises. During bench press and row exercises, the recruitment pattern in each active muscle did not vary with load. During bench press and row exercises, RC muscles contract in a reciprocal direction-specific manner in their role as shoulder joint dynamic stabilizers to counterbalance antero-posterior translation forces. Copyright © 2011 Elsevier Ltd. All rights reserved.
Design and construction of a telescope simulator for LISA optical bench testing
NASA Astrophysics Data System (ADS)
Bogenstahl, J.; Tröbs, M.; d'Arcio, L.; Diekmann, C.; Fitzsimons, E. D.; Hennig, J. S.; Hey, F. G.; Killow, C. J.; Lieser, M.; Lucarelli, S.; Perreur-Lloyd, M.; Pijnenburg, J.; Robertson, D. I.; Taylor, A.; Ward, H.; Weise, D.; Heinzel, G.; Danzmann, K.
2017-11-01
LISA (Laser Interferometer Space Antenna) is a proposed space-based instrument for astrophysical observations via the measurement of gravitational waves at mHz frequencies. The triangular constellation of the three LISA satellites will allow interferometric measurement of the changes in distance along the arms. On board each LISA satellite there will be two optical benches, one for each testmass, that measure the distance to the local test mass and to the remote optical bench on the distant satellite. For technology development, an Optical Bench Elegant Bread Board (OB EBB) is currently under construction. To verify the performance of the EBB, another optical bench - the so-called telescope simulator bench - will be constructed to simulate the beam coming from the far spacecraft. The optical beam from the telescope simulator will be superimposed with the light on the LISA OB, in order to simulate the link between two LISA satellites. Similarly in reverse, the optical beam from the LISA OB will be picked up and measured on the telescope simulator bench. Furthermore, the telescope simulator houses a test mass simulator. A gold coated mirror which can be manipulated by an actuator simulates the test mass movements. This paper presents the layout and design of the bench for the telescope simulator and test mass simulator.
Development of Prototype Production ESR Facilities
1977-07-01
CJISTHIBUTION STATEMENT (ot (he aUxIr&cl entnred in lil^ck 21), If ctlfferert from Wfv.rtj 18. SiJPPi EMENTARV NOTES M9. Kfc y WORDS...Unlike in conventional foundry methods, electroslag castings are made in water-cooled metal molds by remelting of consumable electrodes in... CONSUMABLE ELECTRODE TOP MOLD SLAQ POOL MOLTEN METAL POOL LEVEL DETECTOR MOLTEN METAL POOL ESP INCrOT COPPER LINER mTER JACKET
ERIC Educational Resources Information Center
Collis, B. A.; de Boer, W. F.
1998-01-01
In the Science and Technology department of the University of Twente (Toegepaste Onderwijskunde, T.O., Netherlands), a revolutionary process of institutional change is occurring under the banner of C@MPUS+ initiative. The TeleTOP (Tele-Learning at T.O.) team is committed to blending the best of traditional education with new didactics and advanced…
Can space station software be specified through Ada?
NASA Technical Reports Server (NTRS)
Knoebel, Arthur
1987-01-01
Programming of the space station is to be done in the Ada programming language. A breadboard of selected parts of the work package for Marshall Space Flight Center is to be built, and programming this small part will be a good testing ground for Ada. One coding of the upper levels of the design brings out several problems with top-down design when it is to be carried out strictly within the language. Ada is evaluated on the basis of this experience, and the points raised are compared with other experience as related in the literature. Rapid prototyping is another approach to the initial programming; several different types of prototypes are discussed, and compared with the art of specification. Some solutions are proposed and a number of recommendations presented.
Eble, C.F.; Greb, S.F.; Williams, D.A.; Hower, J.C.
1999-01-01
Eight bench-column samples of the Western Kentucky Number 4 coal bed, collected from an area along the southern margin of the Western Kentucky Coal Field, were analyzed palynologically, petrographically, and geochemically to document both temporal and spatial variability among these parameters. The Western Kentucky Number 4 coal occurs near the top of the Tradewater Formation, is of Early Desmoinesian age, and is correlative with the lower part of the Allegheny Formation of the Appalachian Basin, and Late Bolsovian strata of western Europe. Palynologically, the coal is co-dominated by spores that were produced by lycopod trees (Lycospora and Granasporites medius) and tree ferns. Thin-walled tree fern spores (Punctatisporites minutus, P. minutus, P. rotundus) are more abundant than thick-walled forms (Laevigatosporites globosus, P. granifer). Calamitean spores (Calamospora and Laevigatosporites spp.) are locally abundant as is cordaitean pollen (Florinites). Small fern (Granulatisporites) and small lycopod spores (Densosporites, Cirratriradites, Endosporites and Anacanthotriletes spinosus) are present, but occur in minor amounts. Temporal changes in palynomorph composition occur, but are not uniform between columns. Spatial variability among columns is also evident. Petrographically, the coal is dominated by vitrinite macerals, with telinite and telocollinite generally occurring more commonly than desmocollinite and gelocollinite. Basal benches typically contain high percentages of vitrinite; middle benches usually contain higher percentages of liptinite and inertinite. In about half the studied columns, the terminal coal benches show a slight increase in vitrinite. In the study area, the petrography of the Western Kentucky Number 4 coal is more uniform than the palynology. Ash yields and total sulfur contents are temporally uniform in some columns, but variable in others. In the latter case, higher percentages of ash and sulfur occur at the base of the bed and decrease up to the middle of the bed. The terminal benches of these columns often, but not always, show slight increases in ash or sulfur. Both syngenetic and epigenetic forms of sulfur are present in the Western Kentucky Number 4 coal. The high vitrinite contents and moderate to high sulfur contents suggest that the Western Kentucky Number 4 paleomire was mainly planar and rheotrophic throughout its developmental history. Groundwaters carrying dissolved solutes may have helped neutralize the normally acidic interstitial peat waters allowing for the production of sulfide minerals. Several of the columns with high sulfur contents at the base of the bed occur in faulted areas. The faults could have promoted the flow of groundwaters through the peat, providing an increased dissolved load for acid mitigation and sulfide formation. The concentration of sulfur at the base of the bed may be a function of the peat/underclay contact enhancing sulfide formation. The clay layer may also have acted as an impermeable boundary for downward moving groundwaters, causing mainly lateral, rather than vertical movement along the base of the coal bed.Eight bench-column samples of the Western Kentucky Number 4 coal bed were analyzed palynologically, petrographically, and geochemically to study both temporal and spatial variability among these parameters. Palynologically, the coal is co-dominated by spores that were produced by lycopod trees and tree ferns. Petrographically, the coal is dominated by vitrinite macerals, with telinite and telocollinite generally occurring more commonly than desmocollinite and gelocollinite. The petrography of the coal was found to be more uniform than the palynology.
Multi-Axis Heterodyne Interferometry (MAHI)
NASA Astrophysics Data System (ADS)
Thorpe, James
The detection and measurement of gravitational waves represents humanity’s next, and final, opportunity to open an entirely new spectrum with which to view the universe. The first steps of this process will likely take place later this decade when the second-generation ground-based instruments such as Advanced LIGO approach design sensitivity. While these events will be historic, it will take a space-based detector to access the milliHertz gravitational wave frequency band, a band that is rich in both number and variety of sources. The Laser Interferometer Space Antenna (LISA) concept has been developed over the past two decades in the US and Europe to provide access to this band. The European Space Agency recently selected The Gravitational Universe as the science theme for the 3rd Large-class mission in the Cosmic Visions Programme, with the assumption that a LISA-like instrument would be implemented for launch in 2034. NASA has expressed interest in partnering on this effort and the US community has made its own judgment on the scientific potential of a space-based gravitational wave observatory through the selection of LISA as the 3rd flagship mission in the 2010 Decadal Survey. Much of the effort has been in retiring risk for the unique technologies that comprise a gravitational wave detector. A prime focus of this effort is LISA Pathfinder (LPF), a dedicated technology demonstrator mission led by ESA with contributions from NASA and several member states. LPF’s primary objective is to validate drag-free flight as an approach to realizing an inertial reference mass. Along the way, several important technologies will be demonstrated, including picometer-level heterodyne interferometry. However, there are several important differences between the interferometry design for LISA and that for LPF. These mostly result from the fact that LISA interferometry involves multiple lasers on separate spacecraft whereas LPF can use a single laser on a single spacecraft. We propose to develop a laboratory prototype of a LISA-like interferometric metrology system capable of simultaneously making picometer-level position and nanoradian-level attitude measurements of a free-flying target. In the LISA application, this prototype would represent the short-arm interferometer, measuring the displacement and relative attitude between the gravitational test mass and the spacecraft. This measurement is used both to drive the drag-free attitude and control system as well as to extract the gravitational wave science signal. In addition to the LISA application, such a system would have broader applications in future geodesy and formation-flying missions. The prototype free-flying metrology system will consist of the following subcomponents: an optical bench providing stable pathlengths, an optical target mounted on a precision actuator, a low-noise quadrant photoreceiver for generating differential wavefront signals, and a phase measurement system to measure the individual heterodyne signals and convert them into quantities such as position and angle. In addition to the moving target, the optical bench will include a pair of fixed targets to be used as references. Comparing the two reference interferometers will provide an estimate of the noise performance of the measurement system, while comparing a reference interferometer with the free-flying target will allow us to demonstrate measurement over a large dynamic range. In addition to making performance measurements, we will use this prototype system to explore a number of system-level issues related to free-flying interferometry including initial acquisition, beam-walk effects, and jitter couplings.
Errors of car wheels rotation rate measurement using roller follower on test benches
NASA Astrophysics Data System (ADS)
Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.
2018-03-01
The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.
2012-01-01
Background The Antarctic fungus Lecanicillium muscarium CCFEE 5003 is one of the most powerful chitinolytic organisms. It can produce high level of chitinolytic enzymes in a wide range of temperatures (5-30°C). Chitinolytic enzymes have lot of applications but their industrial production is still rather limited and no cold-active enzymes are produced. In view of massive production of L. muscarium chitinolytic enzymes, its cultivation in bioreactors is mandatory. Microbial cultivation and/or their metabolite production in bioreactors are sometime not possible and must be verified and optimized for possible exploitation. Agitation and aeration are the most important parameters in order to allow process up-scaling to the industrial level. Results In this study, submerged cultures of L. muscarium CCFEE 5003 were carried out in a 2-L bench-top CSTR bioreactor in order to optimise the production of chitinolytic enzymes. The effect of stirrer speed (range 200-500 rpm) and aeration rate (range 0.5-1.5 vvm) combination was studied, by Response Surface Methodology (RSM), in a medium containing 1.0% yeast nitrogen base and 1% colloidal chitin. Optimization was carried out, within a "quadratic D-optimal" model, using quantitative and quantitative-multilevel factors for aeration and agitation, respectively. The model showed very good correlation parameters (R2, 0.931; Q2, 0.869) and the maximum of activity (373.0 U/L) was predicted at ca. 327 rpm and 1.1 vvm. However, the experimental data showed that highest activity (383.7 ± 7.8 U/L) was recorded at 1 vvm and 300 rpm. Evident shear effect caused by stirrer speed and, partially, by high aeration rates were observed. Under optimized conditions in bioreactor the fungus was able to produce a higher number of chitinolytic enzymes than those released in shaken flasks. In addition, production was 23% higher. Conclusions This work demonstrated the attitude of L. muscarium CCFEE 5003 to grow in bench-top bioreactor; outlined the strong influence of aeration and agitation on its growth and enzyme production and identified the optimal conditions for possible production at the industrial level. PMID:22270226
Haji, Faizal A; Khan, Rabia; Regehr, Glenn; Drake, James; de Ribaupierre, Sandrine; Dubrowski, Adam
2015-12-01
As interest in applying cognitive load theory (CLT) to the study and design of pedagogic and technological approaches in healthcare simulation grows, suitable measures of cognitive load (CL) are needed. Here, we report a two-phased study investigating the sensitivity of subjective ratings of mental effort (SRME) and secondary-task performance (signal detection rate, SDR and recognition reaction time, RRT) as measures of CL. In phase 1 of the study, novice learners and expert surgeons attempted a visual-monitoring task under two conditions: single-task (monitoring a virtual patient's heart-rate) and dual-task (tying surgical knots on a bench-top simulator while monitoring the virtual patient's heart-rate). Novices demonstrated higher mental effort and inferior secondary-task performance on the dual-task compared to experts (RRT 1.76 vs. 0.73, p = 0.012; SDR 0.27 vs. 0.97, p < 0.001; SRME 7.75 vs. 2.80, p < 0.001). Similarly, secondary task performance deteriorated from baseline to dual-task among novices (RRT 0.63 vs. 1.76 s, p < 0.006 and SDR 1.00 vs. 0.27, p < 0.001), but not experts (RRT 0.63 vs. 0.73 s, p = 0.124 and SDR 1.00 vs. 0.97, p = 0.178). In phase 2, novices practiced surgical knot-tying on the bench top simulator during consecutive dual-task trials. A significant increase in SDR (F(9,63) = 6.63, p < 0.001, f = 0.97) and decrease in SRME (F(9,63) = 9.39, p < 0.001, f = 1.04) was observed during simulation training, while RRT did not change significantly (F(9,63) = 1.18, p < 0.32, f = 0.41). The results suggest subjective ratings and dual-task performance can be used to track changes in CL among novices, particularly in early phases of simulation-based skills training. The implications for measuring CL in simulation instructional design research are discussed.
Ilyas, Rebecca; Chow, Karyee; Young, J Graham
2015-01-01
Monitoring of urinary pH is an important part of the assessment of patients with urinary tract stones. It provides valuable information about the future stone risk of certain patients and further allows the effective tailoring of medical intervention. Accurate measurement is therefore essential in these patients. The purpose of this study was to determine the most accurate method of measuring urinary pH in an outpatient setting. Materials, Methods, and Participants: Urine samples were collected from 200 patients attending stone clinics at The University Hospital of South Manchester. pH was measured by three commonly used methods: Siemens Clinitek Status pH meter, a hand-held pH meter, and litmus paper read visually. Results were compared with readings simultaneously obtained from a bench-top laboratory pH machine, which is the reference method for pH measurement. The pH readings obtained were analyzed using the Bland-Altman plot. When compared with the reference method, the hand-held pH meter differed the least with a mean bias of 0.0073 and a maximum under-read of -0.2 pH units and maximum over-read of +0.2 pH units. The Siemens Clinitek pH meter differed most with a mean bias of -0.108, with a maximum over-read of +0.99 pH units and a maximum under-read of 0.78 pH units. The pH values obtained with the litmus paper gave similar results to that of the Clinitek pH meter with a mean bias of -0.069, with a maximum over-read of 0.96 and maximum under-read of 0.82 pH units. The hand-held pH device gave urinary pH readings that most closely and consistently matched those of the reference bench-top laboratory machine. This method of pH measurement should be considered in stone clinics in patients with pH-dependent stone risk.
Madani, Amin; Watanabe, Yusuke; Vassiliou, Melina C; Fuchshuber, Pascal; Jones, Daniel B; Schwaitzberg, Steven D; Fried, Gerald M; Feldman, Liane S
2014-10-01
While energy devices are ubiquitous in the operating room, they remain poorly understood and can result in significant complications. The purpose of this study was to estimate the extent to which adding a novel bench-top component improves learning of SAGES' Fundamental Use of Surgical Energy™ (FUSE) electrosurgery curriculum among surgical trainees. Surgical residents participated in a 1-h didactic electrosurgery (ES) course, based on the FUSE curriculum. They were then randomized to one of two groups: an unstructured hands-on session where trainees used ES devices (control group) or a goal-directed hands-on training session (Sim group). Pre- and post-curriculum (immediate and at 3 months) assessments included knowledge of ES (multiple-choice examination), self-perceived competence for each of the 35 course objectives (questionnaire), and self-perceived comfort with performance of seven tasks related to safe use of ES. Data expressed as median[interquartile range], *p < 0.05. 56 (29 control; 27 Sim) surgical trainees completed the curriculum and assessments. Baseline characteristics, including pre-curriculum exam and questionnaire scores, were similar. Total score on the exam improved from 46%[40;54] to 84%[77;91]* for the entire cohort, with higher immediate post-curriculum scores in the Sim group compared to controls (89%[83;94] vs. 83%[71;86]*). At 3 months, performance on the exam declined in both groups, but remained higher in the Sim group (77%[69;90] vs 60%[51;80]*). Participants in both groups reported feeling greater comfort and competence post-curriculum (immediate and at 3 months) compared to baseline. This improvement was greater in the Sim group with a higher proportion feeling "Very Comfortable" or "Fully Competent" (Sim: 3/7 tasks and 28/35 objectives; control: 0/7 tasks and 10/35 objectives). A FUSE-based curriculum improved surgical trainees' knowledge and comfort in the safe use of electrosurgical devices. The addition of a structured interactive bench-top simulation component further improved learning and retention at 3 months.
Paudel, M; MacKenzie, M; Fallone, B; Rathee, S
2012-06-01
To evaluate the performance of a model based image reconstruction in reducing metal artifacts in MVCT systems, and to compare with filtered-back projection (FBP) technique. Iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with pair/triplet production process and the energy dependent response of detectors. The beam spectra for in-house bench-top and TomotherapyTM MVCT are modelled for use in IMPACT. The energy dependent gain of detectors is calculated using a constrained optimization technique and measured attenuation produced by 0 - 24 cm thick solid water slabs. A cylindrical (19 cm diameter) plexiglass phantom containing various central cylindrical inserts (relative electron density of 0.28-1.69) between two steel rods (2 cm diameter) is scanned in the bench-top [the bremsstrahlung radiation from 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C] and TomotherapyTM MVCTs. The FBP reconstructs images from raw signal normalised to air scan and corrected for beam hardening using a uniform plexi-glass cylinder (20 cm diameter). IMPACT starts with FBP reconstructed seed image and reconstructs final image at 1.25 MeV in 150 iterations. FBP produces a visible dark shading in the image between two steel rods that becomes darker with higher density central insert causing 5-8 % underestimation of electron density compared to the case without the steel rods. In the IMPACT image the dark shading connecting the steel rods is nearly removed and the uniform background restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding theoretical values at 1.25 MeV. The dark shading metal artifact due to beam hardening can be removed in MVCT using the iterative reconstruction algorithm such as IMPACT. However, the accurate modelling of detectors' energy dependent response and physical processes are crucial for successful implementation. Funding support for the research is obtained from "Vanier Canada Graduate Scholarship" and "Canadian Institute of Health Research". © 2012 American Association of Physicists in Medicine.
Comparative tests of bench equipment for fuel control system testing of gas-turbine engine
NASA Astrophysics Data System (ADS)
Shendaleva, E. V.
2018-04-01
The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.
2012-01-01
Clinical interventions can be developed through two distinct pathways. In the first, which we call top-down, a well-articulated theory drives the development of the intervention, whereas in the case of a bottom-up approach, clinical experience, more so than a dedicated theoretical perspective, drives the intervention. Using this dialectic, this paper discusses Self-Determination Theory (SDT) [1,2] and Motivational Interviewing (MI) [3] as prototypical examples of a top-down and bottom-up approaches, respectively. We sketch the different starting points, foci and developmental processes of SDT and MI, but equally note the complementary character and the potential for systematic integration between both approaches. Nevertheless, for a deeper integration to take place, we contend that MI researchers might want to embrace autonomy as a fundamental basic process underlying therapeutic change and we discuss the advantages of doing so. PMID:22385828
Foaming phenomenon in bench-scale anaerobic digesters.
Siebels, Amanda M; Long, Sharon C
2013-04-01
The Madison Metropolitan Sewerage District (The District) in Madison, Wisconsin has been experiencing seasonal foaming in their anaerobic biosolids digesters, which has occurred from mid-November to late June for the past few years. The exact cause(s) of foaming is unknown. Previous research findings are unclear as to whether applications of advanced anaerobic digestion processes reduce the foaming potential of digesters. The object of this study was to investigate how configurations of thermophilic and acid phase-thermophilic anaerobic digestion would affect foaming at the bench-scale level compared to single stage mesophilic digestion for The District. Bench-scale anaerobic digesters were fed with a 4 to 4.5% by dry weight of solids content blend of waste activated sludge (WAS) and primary sludge from The District. Foaming potential was monitored using Alka-Seltzer and aeration foaming tests. The bench-scale acid phase-thermophilic digester had a higher foaming potential than the bench-scale mesophilic digester. These results indicate that higher temperatures increase the foaming potential of the bench-scale anaerobic digesters. The bench-scale acid phase-thermophilic digesters had a greater percent (approximately 5 to 10%) volatile solids destruction and a greater percent (approximately 5 to 10%) total solids destruction when compared to the bench-scale mesophilic digester. Overall, for the full-scale foaming experienced by The District, it appears that adding an acid phase or switching to thermophilic digestion would not alleviate The District's foaming issues.
NASA Technical Reports Server (NTRS)
Tuey, Richard C.; Collins, Mary; Caswell, Pamela; Haynes, Bob; Nelson, Michael L.; Holm, Jeanne; Buquo, Lynn; Tingle, Annette; Cooper, Bill; Stiltner, Roy
1996-01-01
This evaluation report contains an introduction, seven chapters, and five appendices. The Introduction describes the purpose, conceptual framework, functional description, and technical report server of the Scientific and Technical Information (STI) Electronic Document Distribution (EDD) project. Chapter 1 documents the results of the prototype STI EDD in actual operation. Chapter 2 documents each NASA center's post processing publication processes. Chapter 3 documents each center's STI software, hardware. and communications configurations. Chapter 7 documents STI EDD policy, practices, and procedures. The appendices consist of (A) the STI EDD Project Plan, (B) Team members, (C) Phasing Schedules, (D) Accessing On-line Reports, and (E) Creating an HTML File and Setting Up an xTRS. In summary, Stage 4 of the NASAwide Electronic Publishing System is the final phase of its implementation through the prototyping and gradual integration of each NASA center's electronic printing systems, desk top publishing systems, and technical report servers, to be able to provide to NASA's engineers, researchers, scientists, and external users, the widest practicable and appropriate dissemination of information concerning its activities and the result thereof to their work stations.
Earth Observations taken by the Expedition 15 Crew
2007-09-20
ISS015-E-29867 (20 Sept. 2007) --- Bingham Canyon Mine, Utah is featured in this image photographed by an Expedition 15 crewmember on the International Space Station. The Bingham Canyon Mine (center) located approximately 32 kilometers to the southeast of Salt Lake City, UT is one of the largest open-pit mines in the world, measuring over 4 kilometers wide and 1,200 meters deep. The mine exploits a porphyry copper, a type of geological structure formed by crystal-rich magma moving upwards through pre-existing rock layers. As the magma cools and crystallizes (forming an igneous rock with large crystals in a fine-grained matrix, known as a porphyry), hot fluids circulate through the magma and surrounding rocks via fractures. This process of hydrothermal alteration typically forms copper-bearing and other minerals in spatial patterns that a geologist recognizes as a potential porphyry copper deposit. Parallel benches (stepped terraces), visible along the western pit face (center left), range from 16 to 25 meters high - these provide access for equipment to work the rock face, as well as maintaining stability of the sloping pit walls. A dark, larger roadway is also visible directly below the benches. Brown to gray, flat topped hills of gangue (waste rock) surround the pit, and are thrown into sharp relief by shadows and the oblique viewing angle of this image. Leachate reservoirs associated with ore processing are visible to the south of the city of Bingham Canyon, UT (right).
Physiological characterization of a broad spectrum reductively dechlorinating consortium
Lorah, M.M.; Majcher, E.; Jones, E.; Driedger, G.; Dworatzek, S.; Graves, D.
2005-01-01
A wetland sediment-derived microbial consortium (WBC-2) was developed by the US Geological Survey and propagated in vitro to large quantities by SiREM Laboratory for potential use in bioaugmentation applications. On the basis of bench-scale tests, the consortium could completely dechlorinate 1,1,2,2-tetrachloroethylene, tetrachloroethylene, trichloroethylene, 1,1,2-trichloroethane, cis- and trans-1,2-dichoroethylene, 1,1-dichloroethylene, 1,2-dichloroethane, and vinyl chloride in culture medium. Batch microcosms were carried out under anaerobic conditions in culture medium with neutral pH and with pH adjusted from acidic (pH 4, 5, and 6) to alkaline (pH 8 and 9). To evaluate oxygen sensitivity of WBC-2, an aliquot was removed from an anaerobic culture vessel and poured into smaller containers on the bench top where a series of oxygen exposures were applied to the culture by bubbling ambient air through the culture at a rate of ??? 100 mL/min. Chlorinated methanes tended to inhibit activity of a wide range of microorganisms. Although toxicity effects from CT addition were observed with WBC-2 in liquid culture at 3 mg/L concentration, WBC-2 in the columns could maintain degradation of CT and chloroform (CF) and of the chlorinated ethanes and ethylenes at CT and CF concentrations of 10 and 20 mg/L, respectively. This is an abstract of a paper presented at the Proceedings of the 8th International In Situ and On-Site Bioremediation Symposium (Baltimore, MD 6/6-9/2005).
Design and Testing of an Active Core for Sandwich Panels
2008-03-01
some degrees of unimorph from the design. In the experiment, the current prototype, which is made of polycarbonate material and Nitinol spring...such as Nitinol , is chosen due to its greater shape memory strain (8.5%), practical fabrication technique, and is relatively in- expansive. 2.2... Nitinol and its volume fractions are 5%, 7.5%, and 10% of the total design domain. The artificial stiffness implemented at the top and bottom right hand
1996-01-01
Real-Time 19 5 Conclusion 23 List of References 25 ii LIST OF FIGURES FIGURE PAGE 3-1 Test Bench Pseudo Code 7 3-2 Fast Convolution...3-1 shows pseudo - code for a test bench with two application nodes. The outer test bench wrapper consists of three functions: pipeline_init, pipeline...exit_func); Figure 3-1. Test Bench Pseudo Code The application wrapper is contained in the pipeline routine and similarly consists of an
NanoBench: An Individually Addressable Nanotube Array
2006-03-25
17 (1999). 5 Cai, L., H. Tabata and T. Kawai, "Probing electrical properties of oriented DNA by conducting atomic force microscopy", Nanotechnology 12...the e-beam hits the other side of the NanoBench. This allows the cells to be kept alive in a biological medium while they are being tested. The key...advantage of the NanoBench is that the e-beam never hits the sample. UHV Technologies Inc. 7 NanoBench: An Individually Addressable Nanotube Array Final
Design and test of a flat-top magnetic field system driven by capacitor banks.
Jiang, Fan; Peng, Tao; Xiao, Houxiu; Zhao, Jianlong; Pan, Yuan; Herlach, Fritz; Li, Liang
2014-04-01
An innovative method for generating a flat-top pulsed magnetic field by means of capacitor banks is developed at the Wuhan National High Magnetic Field Center (WHMFC). The system consists of two capacitor banks as they are normally used to generate a pulsed field. The two discharge circuits (the magnet circuit and the auxiliary circuit) are coupled by a pulse transformer such that the electromotive force (EMF) induced via the transformer in the magnet circuit containing the magnet coil is opposed to the EMF of the capacitor bank. At a certain point before the current pulse in the coil reaches its peak, the auxiliary circuit is triggered. With optimized parameters for charging voltage and trigger delay, the current in the magnet circuit can be approximately kept constant to obtain a flat-top. A prototype was developed at the WHMFC; the magnet circuit was energized by seven 1 MJ (3.2 mF/25 kV) capacitor modules and the auxiliary circuit by four 1 MJ modules. Fields up to 41 T with 6 ms flat-top have been obtained with a conventional user magnet used at the WHMFC.
New Improvements in Magnetic Measurements Laboratory of the ALBA Synchrotron Facility
NASA Astrophysics Data System (ADS)
Campmany, Josep; Marcos, Jordi; Massana, Valentí
ALBA synchrotron facility has a complete insertion devices (ID) laboratory to characterize and produce magnetic devices needed to satisfy the requirements of ALBA's user community. The laboratory is equipped with a Hall-probe bench working in on-the-fly measurement mode allowing the measurement of field maps of big magnetic structures with high accuracy, both in magnetic field magnitude and position. The whole control system of this bench is based on TANGO. The Hall probe calibration range extends between sub-Gauss to 2 Tesla with an accuracy of 100 ppm. Apart from the Hall probe bench, the ID laboratory has a flipping coil bench dedicated to measuring field integrals and a Helmholtz coil bench specially designed to characterize permanent magnet blocks. Also, a fixed stretched wire bench is used to measure field integrals of magnet sets. This device is specifically dedicated to ID construction. Finally, the laboratory is equipped with a rotating coil bench, specially designed for measuring multipolar devices used in accelerators, such as quadrupoles, sextupoles, etc. Recent improvements of the magnetic measurements laboratory of ALBA synchrotron include the design and manufacturing of very thin 3D Hall probe heads, the design and manufacturing of coil sensors for the Rotating coil bench based on multilayered PCB, and the improvement of calibration methodology in order to improve the accuracy of the measurements. ALBA magnetic measurements laboratory is open for external contracts, and has been widely used by national and international institutes such as CERN, ESRF or CIEMAT, as well as magnet manufacturing companies, such as ANTEC, TESLA and I3 M. In this paper, we will present the main features of the measurement benches as well as improvements made so far.
69. (Credit JTL) View beneath marble meter bench showing hydraulic ...
69. (Credit JTL) View beneath marble meter bench showing hydraulic lines leading to water valve hydraulic control cylinders from control handles in bench; strings and pulleys activate meters. - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA
21. DETAIL INTERIOR VIEW OF ORIGINAL BENCH BOARD CONTROLS IN ...
21. DETAIL INTERIOR VIEW OF ORIGINAL BENCH BOARD CONTROLS IN CONTROL ROOM ON LEVEL +77 OF POWERHOUSE #1; THESE PANELS ARE ON LEFT SIDE OF BENCH BOARD CONTROLS. - Bonneville Project, Powerhouse No.1, Spanning Bradford Slough, from Bradford Island, Bonneville, Multnomah County, OR
Measure Twice, Build Once: Bench-Scale Testing to Evaluate Bioretention Media Design
The paper discusses the utility of conducting bench-scale testing on selected bioretention media and media amendments to validate hydrologic properties before installing media and amendments in larger pilot- or full-scale rain garden installations. The bench-scale study conclude...
The Relationship between Trunk Function and Injury among Junior High School Soccer Players
Nakazawa, Rie; Endo, Yasuhiro; Sakamoto, Masaaki
2013-01-01
[Purpose] The purpose of this study was to examine the relationship between trunk stability and injury among young soccer players. [Subjects and Methods] The subjects were 19 male soccer players in junior high school. The presence of injury was noted, and trunk stability was measured by using the bench test and sideways bench test, which were modified from “The 11+” exercises. [Results] There was no significant difference in endurance time in the bench test or sideways bench test between the injury group (n=9) and non-injury group (n=10). Comparison within each group revealed no significant difference in endurance time between the right and left sideways bench tests in the non-injury group; however, the time in the left sideways bench test was significantly longer than that in the right in the injury group. [Conclusion] This study suggests that there is a relationship between asymmetric trunk stability and injury. Further research investigating the relationship between asymmetric trunk function and balance skills is necessary. PMID:24259850
Soluble Protein Analysis using a Compact Bench-top Flow Cytometer
NASA Technical Reports Server (NTRS)
Pappas, Dimitri; Kao, Shib-Hsin; Cyr, Johnathan
2004-01-01
Future space exploration missions will require analytical technology capable of providing both autonomous medical care to the crew and investigative capabilities to researchers. While several promising candidate technologies exist for further development, flow cytometry is an attractive technology as it offers both crew health (blood cell count, leukocyte differential, etc.) and a wide array of biochemistry and immunology assays. research settings, the application of this technique to soluble protein analysis is also possible. Proteomic beads using fluorescent dyes for optical encoding were used to monitor six cytokines simultaneously in cell medium of cell cultures in stationary and rotating cell culture systems. The results of this work demonstrate that a compact flow cytometer, such as a system proposed for space flight, can detect a variety of soluble proteins for crew health and biotechnology experiments during long-term missions.
Transitioning Active Flow Control to Applications
NASA Technical Reports Server (NTRS)
Joslin, Ronald D.; Horta, Lucas G.; Chen, Fang-Jenq
1999-01-01
Active Flow Control Programs at NASA, the U.S. Air Force, and DARPA have been initiated with the goals of obtaining revolutionary advances in aerodynamic performance and maneuvering compared to conventional approaches. These programs envision the use of actuators, sensors, and controllers on applications such as aircraft wings/tails, engine nacelles, internal ducts, nozzles, projectiles, weapons bays, and hydrodynamic vehicles. Anticipated benefits of flow control include reduced weight, part count, and operating cost and reduced fuel burn (and emissions), noise and enhanced safety if the sensors serve a dual role of flow control and health monitoring. To get from the bench-top or laboratory test to adaptive distributed control systems on realistic applications, reliable validated design tools are needed in addition to sub- and large-scale wind-tunnel and flight experiments. This paper will focus on the development of tools for active flow control applications.
Kinetic Analyses of Data from a Human Serum Albumin Assay Using the liSPR System.
Henseleit, Anja; Pohl, Carolin; Kaltenbach, Hans-Michael; Hettwer, Karina; Simon, Kirsten; Uhlig, Steffen; Haustein, Natalie; Bley, Thomas; Boschke, Elke
2015-01-19
We used the interaction between human serum albumin (HSA) and a high-affinity antibody to evaluate binding affinity measurements by the bench-top liSPR system (capitalis technology GmbH). HSA was immobilized directly onto a carboxylated sensor layer, and the mechanism of interaction between the antibody and HSA was investigated. The bivalence and heterogeneity of the antibody caused a complex binding mechanism. Three different interaction models (1:1 binding, heterogeneous analyte, bivalent analyte) were compared, and the bivalent analyte model best fit the curves obtained from the assay. This model describes the interaction of a bivalent analyte with one or two ligands (A + L ↔ LA + L ↔ LLA). The apparent binding affinity for this model measured 37 pM for the first reaction step, and 20 pM for the second step.
Kinetic Analyses of Data from a Human Serum Albumin Assay Using the liSPR System
Henseleit, Anja; Pohl, Carolin; Kaltenbach, Hans-Michael; Hettwer, Karina; Simon, Kirsten; Uhlig, Steffen; Haustein, Natalie; Bley, Thomas; Boschke, Elke
2015-01-01
We used the interaction between human serum albumin (HSA) and a high-affinity antibody to evaluate binding affinity measurements by the bench-top liSPR system (capitalis technology GmbH). HSA was immobilized directly onto a carboxylated sensor layer, and the mechanism of interaction between the antibody and HSA was investigated. The bivalence and heterogeneity of the antibody caused a complex binding mechanism. Three different interaction models (1:1 binding, heterogeneous analyte, bivalent analyte) were compared, and the bivalent analyte model best fit the curves obtained from the assay. This model describes the interaction of a bivalent analyte with one or two ligands (A + L ↔ LA + L ↔ LLA). The apparent binding affinity for this model measured 37 pM for the first reaction step, and 20 pM for the second step. PMID:25607476
Selecting an A1C Point-of-Care Instrument
Yong, Ee Vonn; Rasinen, Casey
2015-01-01
A1C point-of-care (POC) instruments benefit patients with diabetes by facilitating clinician decision making that results in significant glycemic improvements. Three National Glycohemoglobin Standardization Program (NGSP)–certified POC products are available in the United States: the handheld A1CNow (formerly manufactured by Bayer Diabetes Care but now made by Chek Diagnostics) and two bench-top models called the Axis-Shield Afinion Analyzer and the Siemens DCA Vantage. This article compares the three available NGSP-certified POC products in terms of accuracy, precision, ease of use, cost, and additional features. Its goal is to aid health care facilities in conveniently identifying the A1C POC product that best meets their needs. It additionally reviews evidence that supports the continued use of A1C POC instruments in the clinical arena. PMID:26300614
Simultaneous Soft Sensing of Tissue Contact Angle and Force for Millimeter-scale Medical Robots
Arabagi, Veaceslav; Gosline, Andrew; Wood, Robert J.; Dupont, Pierre E.
2013-01-01
A novel robotic sensor is proposed to measure both the contact angle and the force acting between the tip of a surgical robot and soft tissue. The sensor is manufactured using a planar lithography process that generates microchannels that are subsequently filled with a conductive liquid. The planar geometry is then molded onto a hemispherical plastic scaffolding in a geometric configuration enabling estimation of the contact angle (angle between robot tip tangent and tissue surface normal) by the rotation of the sensor around its roll axis. Contact force can also be estimated by monitoring the changes in resistance in each microchannel. Bench top experimental results indicate that, on average, the sensor can estimate the angle of contact to within ±2° and the contact force to within ±5.3 g. PMID:24241496
Catalytic wet-oxidation of a mixed liquid waste: COD and AOX abatement.
Goi, D; de Leitenburg, C; Trovarelli, A; Dolcetti, G
2004-12-01
A series of catalytic wet oxidation (CWO) reactions, at temperatures of 430-500 K and in a batch bench-top pressure vessel were carried out utilizing a strong wastewater composed of landfill leachate and heavily organic halogen polluted industrial wastewater. A CeO2-SiO2 mixed oxide catalyst with large surface area to assure optimal oxidation performance was prepared. The catalytic process was examined during batch reactions controlling Chemical Oxygen Demand (COD) and Adsorbable Organic Halogen (AOX) parameters, resulting AOX abatement to achieve better effect. Color and pH were also controlled during batch tests. A simple first order-two stage reaction behavior was supposed and verified with the considered parameters. Finally an OUR test was carried out to evaluate biodegradability changes of wastewater as a result of the catalytic reaction.
Benzyl Alcohol-Mediated Versatile Method to Fabricate Nonstoichiometric Metal Oxide Nanostructures.
Qamar, Mohammad; Adam, Alaaldin; Azad, Abdul-Majeed; Kim, Yong-Wah
2017-11-22
Nanostructured metal oxides with cationic or anionic deficiency find applications in a wide range of technological areas including the energy sector and environment. However, a facile route to prepare such materials in bulk with acceptable reproducibility is still lacking; many synthesis techniques are still only bench-top and cannot be easily scaled-up. Here, we report that the benzyl alcohol (BA)-mediated method is capable of producing a host of nanostructured metal oxides (MO x , where M = Ti, Zn, Ce, Sn, In, Ga, or Fe) with inherent nonstoichiometry. It employs multifunctional BA as a solvent, a reducing agent, and a structure-directing agent. Depending on the oxidation states of metal, elemental or nonstoichiometric oxide forms are obtained. Augmented photoelectrochemical oxidation of water under visible light by some of these nonstoichiometric oxides highlights the versatility of the BA-mediated synthesis protocol.
Whole genome sequencing in clinical and public health microbiology
Kwong, J. C.; McCallum, N.; Sintchenko, V.; Howden, B. P.
2015-01-01
SummaryGenomics and whole genome sequencing (WGS) have the capacity to greatly enhance knowledge and understanding of infectious diseases and clinical microbiology. The growth and availability of bench-top WGS analysers has facilitated the feasibility of genomics in clinical and public health microbiology. Given current resource and infrastructure limitations, WGS is most applicable to use in public health laboratories, reference laboratories, and hospital infection control-affiliated laboratories. As WGS represents the pinnacle for strain characterisation and epidemiological analyses, it is likely to replace traditional typing methods, resistance gene detection and other sequence-based investigations (e.g., 16S rDNA PCR) in the near future. Although genomic technologies are rapidly evolving, widespread implementation in clinical and public health microbiology laboratories is limited by the need for effective semi-automated pipelines, standardised quality control and data interpretation, bioinformatics expertise, and infrastructure. PMID:25730631
Whole genome sequencing in clinical and public health microbiology.
Kwong, J C; McCallum, N; Sintchenko, V; Howden, B P
2015-04-01
Genomics and whole genome sequencing (WGS) have the capacity to greatly enhance knowledge and understanding of infectious diseases and clinical microbiology.The growth and availability of bench-top WGS analysers has facilitated the feasibility of genomics in clinical and public health microbiology.Given current resource and infrastructure limitations, WGS is most applicable to use in public health laboratories, reference laboratories, and hospital infection control-affiliated laboratories.As WGS represents the pinnacle for strain characterisation and epidemiological analyses, it is likely to replace traditional typing methods, resistance gene detection and other sequence-based investigations (e.g., 16S rDNA PCR) in the near future.Although genomic technologies are rapidly evolving, widespread implementation in clinical and public health microbiology laboratories is limited by the need for effective semi-automated pipelines, standardised quality control and data interpretation, bioinformatics expertise, and infrastructure.
Pre-clinical characterization of tissue engineering constructs for bone and cartilage regeneration
Trachtenberg, Jordan E.; Vo, Tiffany N.; Mikos, Antonios G.
2014-01-01
Pre-clinical animal models play a crucial role in the translation of biomedical technologies from the bench top to the bedside. However, there is a need for improved techniques to evaluate implanted biomaterials within the host, including consideration of the care and ethics associated with animal studies, as well as the evaluation of host tissue repair in a clinically relevant manner. This review discusses non-invasive, quantitative, and real-time techniques for evaluating host-materials interactions, quality and rate of neotissue formation, and functional outcomes of implanted biomaterials for bone and cartilage tissue engineering. Specifically, a comparison will be presented for pre-clinical animal models, histological scoring systems, and non-invasive imaging modalities. Additionally, novel technologies to track delivered cells and growth factors will be discussed, including methods to directly correlate their release with tissue growth. PMID:25319726
Pre-clinical characterization of tissue engineering constructs for bone and cartilage regeneration.
Trachtenberg, Jordan E; Vo, Tiffany N; Mikos, Antonios G
2015-03-01
Pre-clinical animal models play a crucial role in the translation of biomedical technologies from the bench top to the bedside. However, there is a need for improved techniques to evaluate implanted biomaterials within the host, including consideration of the care and ethics associated with animal studies, as well as the evaluation of host tissue repair in a clinically relevant manner. This review discusses non-invasive, quantitative, and real-time techniques for evaluating host-materials interactions, quality and rate of neotissue formation, and functional outcomes of implanted biomaterials for bone and cartilage tissue engineering. Specifically, a comparison will be presented for pre-clinical animal models, histological scoring systems, and non-invasive imaging modalities. Additionally, novel technologies to track delivered cells and growth factors will be discussed, including methods to directly correlate their release with tissue growth.
Compact RGBY light sources with high luminance for laser display applications
NASA Astrophysics Data System (ADS)
Paschke, Katrin; Blume, Gunnar; Werner, Nils; Müller, André; Sumpf, Bernd; Pohl, Johannes; Feise, David; Ressel, Peter; Sahm, Alexander; Bege, Roland; Hofmann, Julian; Jedrzejczyk, Daniel; Tränkle, Günther
2018-02-01
Watt-class visible laser light with a high luminance can be created with high-power GaAs-based lasers either directly in the red spectral region or using single-pass second harmonic generation (SHG) for the colors in the blue-yellow spectral region. The concepts and results of red- and near infrared-emitting distributed Bragg reflector tapered lasers and master oscillator power amplifier systems as well as their application for SHG bench-top experiments and miniaturized modules are presented. Examples of these high-luminance light sources aiming at different applications such as flying spot display or holographic 3D cinema are discussed in more detail. The semiconductor material allows an easy adaptation of the wavelength allowing techniques such as six-primary color 3D projection or color space enhancement by adding a fourth yellow color.
Photoacoustic imaging: a potential new tool for arthritis
NASA Astrophysics Data System (ADS)
Wang, Xueding
2012-12-01
The potential application of photoacoustic imaging (PAI) technology to diagnostic imaging and therapeutic monitoring of inflammatory arthritis has been explored. The feasibility of our bench-top joint imaging systems in delineating soft articular tissue structures in a noninvasive manner was validated first on rat models and then on human peripheral joints. Based on the study on commonly used arthritis rat models, the capability of PAI to differentiate arthritic joints from the normal was also examined. With sufficient imaging depth, PAI can realize tomographic imaging of a human peripheral joint or a small-animal joint as a whole organ noninvasively. By presenting additional optical contrast and tissue functional information such as blood volume and blood oxygen saturation, PAI may provide an opportunity for early diagnosis of inflammatory joint disorders, e.g. rheumatoid arthritis, and for monitoring of therapeutic outcomes with improved sensitivity and accuracy.
NASA Technical Reports Server (NTRS)
Moynihan, Gary P.
1992-01-01
In June 1991, the MITRE Corporation submitted a series of recommendations as part of a Marshall Space Flight Center (MSFC) Management Information System Requirements Study, initiated by the Information Systems Office (ISO). A major recommendation of the study was to develop an Executive Information System (EIS) for MSFC executives. ISO was directed, by center management, to proceed with the development of a Center-Wide Executive Information System. Existing EIS prototypes, developed by the Space Shuttle Projects Office and the Payload Projects Office, were reviewed. These existing MSFC prototypes were considered not to encompass the required functionality needed on a center-wide basis. A follow-up study by MITRE provided top-level system requirements. These were later incorporated into a final requirements specification document by Boeing Computer Support Services.
Scalable and fault tolerant orthogonalization based on randomized distributed data aggregation
Gansterer, Wilfried N.; Niederbrucker, Gerhard; Straková, Hana; Schulze Grotthoff, Stefan
2013-01-01
The construction of distributed algorithms for matrix computations built on top of distributed data aggregation algorithms with randomized communication schedules is investigated. For this purpose, a new aggregation algorithm for summing or averaging distributed values, the push-flow algorithm, is developed, which achieves superior resilience properties with respect to failures compared to existing aggregation methods. It is illustrated that on a hypercube topology it asymptotically requires the same number of iterations as the optimal all-to-all reduction operation and that it scales well with the number of nodes. Orthogonalization is studied as a prototypical matrix computation task. A new fault tolerant distributed orthogonalization method rdmGS, which can produce accurate results even in the presence of node failures, is built on top of distributed data aggregation algorithms. PMID:24748902
ERIC Educational Resources Information Center
Hughes, Stephen W.
2010-01-01
In this article some basic laboratory bench experiments are described that are useful for teaching high school students some of the basic principles of stellar astrophysics. For example, in one experiment, students slam a plastic water-filled bottle down onto a bench, ejecting water towards the ceiling, illustrating the physics associated with a…
30 CFR 816.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
30 CFR 817.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
30 CFR 817.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
30 CFR 817.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
30 CFR 816.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
30 CFR 816.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
30 CFR 816.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
30 CFR 817.74 - Disposal of excess spoil: Preexisting benches.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to a lower preexisting bench by means of gravity transport may be approved by the regulatory authority provided that— (1) The gravity transport courses are determined on a site-specific basis by the..., and downslope of the lower bench should excess spoil accidentally move; (2) All gravity transported...
Optical Bench Interferometer - From LISA Pathfinder to NGO/eLISA
NASA Astrophysics Data System (ADS)
Taylor, A.; d'Arcio, L.; Bogenstahl, J.; Danzmann, K.; Diekmann, C.; Fitzsimons, E. D.; Gerberding, O.; Heinzel, G.; Hennig, J.-S.; Hogenhuis, H.; Killow, C. J.; Lieser, M.; Lucarelli, S.; Nikolov, S.; Perreur-Lloyd, M.; Pijnenburg, J.; Robertson, D. I.; Sohmer, A.; Tröbs, M.; Ward, H.; Weise, D.
2013-01-01
We present a short summary of some optical bench construction and alignment developments that build on experience gained during the LISA Pathfinder optical bench assembly. These include evolved fibre injectors, a new beam vector measurement system, and thermally stable mounting hardware. The beam vector measurement techniques allow the alignment of beams to targets with absolute accuracy of a few microns and 20 microradians. We also describe a newly designed ultra-low-return beam dump that is expected to be a crucial element in the control of ghost beams on the optical benches.
NASA Astrophysics Data System (ADS)
Patil, Riya Raghuvir
Networks of communicating agents require distributed algorithms for a variety of tasks in the field of network analysis and control. For applications such as swarms of autonomous vehicles, ad hoc and wireless sensor networks, and such military and civilian applications as exploring and patrolling a robust autonomous system that uses a distributed algorithm for selfpartitioning can be significantly helpful. A single team of autonomous vehicles in a field may need to self-dissemble into multiple teams, conducive to completing multiple control tasks. Moreover, because communicating agents are subject to changes, namely, addition or failure of an agent or link, a distributed or decentralized algorithm is favorable over having a central agent. A framework to help with the study of self-partitioning of such multi agent systems that have most basic mobility model not only saves our time in conception but also gives us a cost effective prototype without negotiating the physical realization of the proposed idea. In this thesis I present my work on the implementation of a flexible and distributed stochastic partitioning algorithm on the LegoRTM Mindstorms' NXT on a graphical programming platform using National Instruments' LabVIEW(TM) forming a team of communicating agents via NXT-Bee radio module. We single out mobility, communication and self-partition as the core elements of the work. The goal is to randomly explore a precinct for reference sites. Agents who have discovered the reference sites announce their target acquisition to form a network formed based upon the distance of each agent with the other wherein the self-partitioning begins to find an optimal partition. Further, to illustrate the work, an experimental test-bench of five Lego NXT robots is presented.
Raza, Syed T
2013-06-01
A circular aortic stapler has been developed to anastomose the open end of the aorta to a size-matched Dacron tube graft in one quick motion and without having to pull sutures through the aortic wall. A prototype was developed, and its design and function were tested in bench experiments and compared with hand-sewn anastomosis. The basic design of the stapler is a central rod (anvil) surrounded by 10 stapling limbs, which can be closed over the anvil in a full circle, with staples extruded by turning a knob at the back. To test its function, a Dacron tube graft was inserted in the middle of a length of bovine aorta. One side was anastomosed with the stapler and the other hand-sewn in each of 10 experiments. Bovine blood was infused under increasing pressure. It took considerably less time to complete the stapled anastomosis than the hand-sewn side (3 minutes, 46 seconds versus 15 minutes, 42 seconds). Initial leak occurred at low pressures on the hand-sewn side (mean pressure 40 mm Hg) compared with the stapled side (mean pressure 70 mm Hg). In 7 of 10 experiments, the leak became too brisk on the hand-sewn side to sustain pressure, compared with 3 of 10 with stapled anastomoses. The stapling device performed well in all cases except when the bovine aorta was too thick for the staples (two cases) or when there was a missed branch at the anastomotic site (one case). These experiments validate the concept and the design of this aortic stapler. There are some limitations in the current design, which will need to be modified before its use in live animals or clinically.
Quantum efficiency test set up performances for NIR detector characterization at ESTEC
NASA Astrophysics Data System (ADS)
Crouzet, P.-E.; Duvet, L.; De Wit, F.; Beaufort, T.; Blommaert, S.; Butler, B.; Van Duinkerken, G.; ter Haar, J.; Heijnen, J.; van der Luijt, K.; Smit, H.; Viale, T.
2014-07-01
The Payload Technology Validation Section (Future mission preparation Office) at ESTEC is in charge of specific mission oriented validation activities, for science and robotic exploration missions, aiming at reducing development risks in the implementation phase. These activities take place during the early mission phases or during the implementation itself. In this framework, a test set up to characterize the quantum efficiency of near infrared detectors has been developed. The first detector to be tested will an HAWAII-2RG detector with a 2.5μm cut off, it will be used as commissioning device in preparation to the tests of prototypes European detectors developed under ESA funding. The capability to compare on the same setup detectors from different manufacturers will be a unique asset for the future mission preparation office. This publication presents the performances of the quantum efficiency test bench to prepare measurements on the HAWAII-2RG detector. A SOFRADIR Saturn detector has been used as a preliminary test vehicle for the bench. A test set up with a lamp, chopper, monochromator, pinhole and off axis mirrors allows to create a spot of 1mm diameter between 700nm and 2.5μm.The shape of the beam has been measured to match the rms voltage read by the Merlin Lock -in amplifier and the amplitude of the incoming signal. The reference detectors have been inter-calibrated with an uncertainty up to 3 %. For the measurement with HAWAII-2RG detector, the existing cryostat [1] has been modified to adapt cold black baffling, a cold filter wheel and a sapphire window. An statistic uncertainty of +/-2.6% on the quantum efficiency on the detector under test measurement is expected.
Sand and Dust Testing of Wheeled and Tracked Vehicles and Stationary Equipment
2009-11-18
early stages of development of an automotive system or stationary equipment there may be components and sub-systems that need to be tested for...suitability to operate in dust before final prototypes are available for end item or system-level testing. At this stage of development, component or...Method 510, or TOP 1-2-621 does not include functional operation during active testing. Additionally, testing by using either of these two documents is
Luzio de Melo, Paulo; da Silva, Miguel Tavares; Martins, Jorge; Newman, Dava
2015-05-01
Functional electrical stimulation (FES) has been used over the last decades as a method to rehabilitate lost motor functions of individuals with spinal cord injury, multiple sclerosis, and post-stroke hemiparesis. Within this field, researchers in need of developing FES-based control solutions for specific disabilities often have to choose between either the acquisition and integration of high-performance industry-level systems, which are rather expensive and hardly portable, or develop custom-made portable solutions, which despite their lower cost, usually require expert-level electronic skills. Here, a flexible low-cost microcontroller-based platform for rapid prototyping of FES neuroprostheses is presented, designed for reduced execution complexity, development time, and production cost. For this reason, the Arduino open-source microcontroller platform was used, together with off-the-shelf components whenever possible. The developed system enables the rapid deployment of portable FES-based gait neuroprostheses, being flexible enough to allow simple open-loop strategies but also more complex closed-loop solutions. The system is based on a modular architecture that allows the development of optimized solutions depending on the desired FES applications, even though the design and testing of the platform were focused toward drop foot correction. The flexibility of the system was demonstrated using two algorithms targeting drop foot condition within different experimental setups. Successful bench testing of the device in healthy subjects demonstrated these neuroprosthesis platform capabilities to correct drop foot. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Terahertz Radiometer for Outer Planet and Moon Atmospheres (TROPA)
NASA Technical Reports Server (NTRS)
Schlecht, E. T.; Jamnejad, V.; Jarnot, R. F.; Raffanti, R.; Lin, R.
2012-01-01
We are developing a prototype instrument platform to demonstrate the feasibility of a wideband spectrometer for planetary applications under a three-year NASA research program. This development focuses on three specific areas needing advancement. First, the terahertz portion consists of an optical bench with dual heterodyne Schottky-mixer based receivers, one for each band. The beams entering the horns of the two receivers are de-multiplexed from the input beam by a polarizing beam splitter. The blocks containing the 560 and 1200 GHz mixer are more highly integrated than previous space instruments to reduce mass and volume. The receivers take a fundamental pump frequency near 30 GHz and multiply up to the submillimeter range. Second, a rapid-tuning, low-phase noise, and low-power 33 GHz range LO synthesizer is being prototyped. The low phase noise requirement is needed because of the factor of 36 multiplication to reach 1200 GHz, giving a requirement that the integrated phase noise from 100 kHz up be less than 0.6 degrees. The synthesizer will require about 6 watts. Finally, we are developing an advanced polyphase filter back-end spectrum analyzer with a bandwidth of 750 MHz, and power consumption of about 3 Watts and 4096 channels. This system is based on a simple three-chip architecture, having a commercial 1.5 GS/s analog-to-digital converter, an ASIC to do the filtering and an advanced FPGA for data processing and control.
A Prototype for Content-Rich Decision-Making Support in NOAA using Data as an Asset
NASA Astrophysics Data System (ADS)
Austin, M.; Peng, G.
2015-12-01
Data Producers and Data Providers do not always collaborate to ensure that the data meets the needs of a broad range of user communities. User needs are not always considered in the beginning of the data production and delivery phases. Often data experts are required to explain or create custom output so that the data can be used by decision makers. Lack of documentation and quality information can result in poor user acceptance or data misinterpretation. This presentation will describe how new content integration tools have been created by NOAA's National Environmental Satellite, Data, and Information Service (NESDIS) to improve quality throughout the data management lifecycle. The prototype integrates contents into a decision-making support tool from NOAA's Observing System Integrated Assessment (NOSIA) Value Tree, NOAA's Data Catalog/Digital Object Identifier (DOI) projects (collection-level metadata) and Data/Stewardship Maturity Matrices (Data and Stewardship Quality Rating Information). The National Centers for Environmental Information's (NCEI) Global Historical Climatology Network-Monthly (GHCN) dataset is used as a case study to formulate/develop the prototype tool and demonstrate its power with the content-centric approach in addition to completeness of metadata elements. This demonstrates the benefits of the prototype tool in both bottom roll-up and top roll-down fashion. The prototype tool delivers a standards based methodology that allows users to determine the quality and value of data that is fit for purpose. It encourages data producers and data providers/stewards to consider users' needs prior to data creation and dissemination resulting in user driven data requirements increasing return on investment.
Validity of the Myotest® in measuring force and power production in the squat and bench press.
Comstock, Brett A; Solomon-Hill, Glenn; Flanagan, Shawn D; Earp, Jacob E; Luk, Hui-Ying; Dobbins, Kathryn A; Dunn-Lewis, Courtenay; Fragala, Maren S; Ho, Jen-Yu; Hatfield, Disa L; Vingren, Jakob L; Denegar, Craig R; Volek, Jeff S; Kupchak, Brian R; Maresh, Carl M; Kraemer, William J
2011-08-01
The purpose of this study was to verify the concurrent validity of a bar-mounted Myotest® instrument in measuring the force and power production in the squat and bench press exercises when compared to the gold standard of a computerized linear transducer and force platform system. Fifty-four men (bench press: 39-171 kg; squat: 75-221 kg) and 43 women (bench press: 18-80 kg; squat: 30-115 kg) (age range 18-30 years) performed a 1 repetition maximum (1RM) strength test in bench press and squat exercises. Power testing consisted of the jump squat and the bench throw at 30% of each subject's 1RM. During each measurement, both the Myotest® instrument and the Celesco linear transducer of the directly interfaced BMS system (Ballistic Measurement System [BMS] Innervations Inc, Fitness Technology force plate, Skye, South Australia, Australia) were mounted to the weight bar. A strong, positive correlation (r) between the Myotest and BMS systems and a high correlation of determination (R2) was demonstrated for bench throw force (r = 0.95, p < 0.05) (R2 = 0.92); bench throw power (r = 0.96, p < 0.05) (R2 = 0.93); squat jump force (r = 0.98, p < 0.05) (R2 = 0.97); and squat jump power (r = 0.91, p < 0.05) (R2 = 0.82). In conclusion, when fixed on the bar in the vertical axis, the Myotest is a valid field instrument for measuring force and power in commonly used exercise movements.
A comparison of muscle activity in concentric and counter movement maximum bench press.
van den Tillaar, Roland; Ettema, Gertjan
2013-01-01
The purpose of this study was to compare the kinematics and muscle activation patterns of regular free-weight bench press (counter movement) with pure concentric lifts in the ascending phase of a successful one repetition maximum (1-RM) attempt in the bench press. Our aim was to evaluate if diminishing potentiation could be the cause of the sticking region. Since diminishing potentiation cannot occur in pure concentric lifts, the occurrence of a sticking region in this type of muscle actions would support the hypothesis that the sticking region is due to a poor mechanical position. Eleven male participants (age 21.9 ± 1.7 yrs, body mass 80.7 ± 10.9 kg, body height 1.79 ± 0.07 m) conducted 1-RM lifts in counter movement and in pure concentric bench presses in which kinematics and EMG activity were measured. In both conditions, a sticking region occurred. However, the start of the sticking region was different between the two bench presses. In addition, in four of six muscles, the muscle activity was higher in the counter movement bench press compared to the concentric one. Considering the findings of the muscle activity of six muscles during the maximal lifts it was concluded that the diminishing effect of force potentiation, which occurs in the counter movement bench press, in combination with a delayed muscle activation unlikely explains the existence of the sticking region in a 1-RM bench press. Most likely, the sticking region is the result of a poor mechanical force position.
A Comparison of Muscle Activity in Concentric and Counter Movement Maximum Bench Press
van den Tillaar, Roland; Ettema, Gertjan
2013-01-01
The purpose of this study was to compare the kinematics and muscle activation patterns of regular free-weight bench press (counter movement) with pure concentric lifts in the ascending phase of a successful one repetition maximum (1-RM) attempt in the bench press. Our aim was to evaluate if diminishing potentiation could be the cause of the sticking region. Since diminishing potentiation cannot occur in pure concentric lifts, the occurrence of a sticking region in this type of muscle actions would support the hypothesis that the sticking region is due to a poor mechanical position. Eleven male participants (age 21.9 ± 1.7 yrs, body mass 80.7 ± 10.9 kg, body height 1.79 ± 0.07 m) conducted 1-RM lifts in counter movement and in pure concentric bench presses in which kinematics and EMG activity were measured. In both conditions, a sticking region occurred. However, the start of the sticking region was different between the two bench presses. In addition, in four of six muscles, the muscle activity was higher in the counter movement bench press compared to the concentric one. Considering the findings of the muscle activity of six muscles during the maximal lifts it was concluded that the diminishing effect of force potentiation, which occurs in the counter movement bench press, in combination with a delayed muscle activation unlikely explains the existence of the sticking region in a 1-RM bench press. Most likely, the sticking region is the result of a poor mechanical force position. PMID:24235985
Microbial battery for efficient energy recovery.
Xie, Xing; Ye, Meng; Hsu, Po-Chun; Liu, Nian; Criddle, Craig S; Cui, Yi
2013-10-01
By harnessing the oxidative power of microorganisms, energy can be recovered from reservoirs of less-concentrated organic matter, such as marine sediment, wastewater, and waste biomass. Left unmanaged, these reservoirs can become eutrophic dead zones and sites of greenhouse gas generation. Here, we introduce a unique means of energy recovery from these reservoirs-a microbial battery (MB) consisting of an anode colonized by microorganisms and a reoxidizable solid-state cathode. The MB has a single-chamber configuration and does not contain ion-exchange membranes. Bench-scale MB prototypes were constructed from commercially available materials using glucose or domestic wastewater as electron donor and silver oxide as a coupled solid-state oxidant electrode. The MB achieved an efficiency of electrical energy conversion of 49% based on the combustion enthalpy of the organic matter consumed or 44% based on the organic matter added. Electrochemical reoxidation of the solid-state electrode decreased net efficiency to about 30%. This net efficiency of energy recovery (unoptimized) is comparable to methane fermentation with combined heat and power.
Imaging IR spectrometer, phase 2
NASA Technical Reports Server (NTRS)
Gradie, Jonathan; Lewis, Ralph; Lundeen, Thomas; Wang, Shu-I
1990-01-01
The development is examined of a prototype multi-channel infrared imaging spectrometer. The design, construction and preliminary performance is described. This instrument is intended for use with JPL Table Mountain telescope as well as the 88 inch UH telescope on Mauna Kea. The instrument is capable of sampling simultaneously the spectral region of 0.9 to 2.6 um at an average spectral resolution of 1 percent using a cooled (77 K) optical bench, a concave holographic grating and a special order sorting filter to allow the acquisition of the full spectral range on a 128 x 128 HgCdTe infrared detector array. The field of view of the spectrometer is 0.5 arcsec/pixel in mapping mode and designed to be 5 arcsec/pixel in spot mode. The innovative optical design has resulted in a small, transportable spectrometer, capable of remote operation. Commercial applications of this spectrometer design include remote sensing from both space and aircraft platforms as well as groundbased astronomical observations.
Fabry-Perot Interferometer for Column CO2
NASA Technical Reports Server (NTRS)
Heaps, William S.; Kawa, Randolph; Bhartia, P. K. (Technical Monitor)
2002-01-01
Global atmospheric CO2 measurements are essential to resolving significant discrepancies in our understanding of the global carbon budget and, hence, humankind's role in global climate change. The science measurement requirements for CO2 are extremely demanding (precision approx. 0.3%). No atmospheric chemical species has ever been measured from space with this precision. We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere. Preliminary design studies indicate that the method will be able to achieve the sensitivity and signal-to-noise detection required to measure column CO2 at the target specification. The objective of this program is to construct a prototype instrument for deployment on an aircraft to test the instrument performance and our ability to retrieve the data in the real atmosphere. To date we have assembled a laboratory bench system to begin testing the optical and electronic components. We are also measuring signal and noise levels in actual sunlight to evaluate component performance.
A Prototype Actuator Concept for Membrane Boundary Vibration Control
NASA Technical Reports Server (NTRS)
Solter, Micah J.
2005-01-01
In conjunction with the research in ultra-lightweight deployable spacecraft and membrane structures is an underlying need for shape and vibration control. For thin film membrane structures, fundamental modes of vibration for the membrane can be excited through station keeping, attitude adjustments, orbital maneuvers, or contact with space junk or micrometeorites. In order to maintain structural integrity as well as surface shape contour, which may be essential for inflatable antennas, reflective surfaces, or solar sails; vibration damping is a necessary component. This paper discusses development of an actuator attached at the membrane boundary, containing two types of piezoelectric elements, which can be used to perform active control of vibration from the boundary of a membrane. The actuator is designed to control the membrane out-of-plane displacement and in-plane tension by varying the boundary conditions. Results from an initial experimental evaluation of the concept are presented with bench tests of the actuator alone, and with the actuator connected to a large membrane.
Precise Truss Assembly using Commodity Parts and Low Precision Welding
NASA Technical Reports Server (NTRS)
Komendera, Erik; Reishus, Dustin; Dorsey, John T.; Doggett, William R.; Correll, Nikolaus
2013-01-01
We describe an Intelligent Precision Jigging Robot (IPJR), which allows high precision assembly of commodity parts with low-precision bonding. We present preliminary experiments in 2D that are motivated by the problem of assembling a space telescope optical bench on orbit using inexpensive, stock hardware and low-precision welding. An IPJR is a robot that acts as the precise "jigging", holding parts of a local assembly site in place while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (in this case, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. We report the challenges of designing the IPJR hardware and software, analyze the error in assembly, document the test results over several experiments including a large-scale ring structure, and describe future work to implement the IPJR in 3D and with micron precision.
Production of hydrogen from biomass by catalytic steam reforming of fast pyrolysis oil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Czernik, S.; Wang, D.; Chornet, E.
1998-08-01
Hydrogen is the prototype of the environmentally cleanest fuel of interest for power generation using fuel cells and for transportation. The thermochemical conversion of biomass to hydrogen can be carried out through two distinct strategies: (a) gasification followed by water-gas shift conversion, and (b) catalytic steam reforming of specific fractions derived from fast pyrolysis and aqueous/steam processes of biomass. This paper presents the latter route that begins with fast pyrolysis of biomass to produce bio-oil. This oil (as a whole or its selected fractions) can be converted to hydrogen via catalytic steam reforming followed by a water-gas shift conversion step.more » Such a process has been demonstrated at the bench scale using model compounds, poplar oil aqueous fraction, and the whole pyrolysis oil with commercial Ni-based steam reforming catalysts. Hydrogen yields as high as 85% have been obtained. Catalyst initial activity can be recovered through regeneration cycles by steam or CO{sub 2} gasification of carbonaceous deposits.« less
Team building: electronic management-clinical translational research (eM-CTR) systems.
Cecchetti, Alfred A; Parmanto, Bambang; Vecchio, Marcella L; Ahmad, Sjarif; Buch, Shama; Zgheib, Nathalie K; Groark, Stephen J; Vemuganti, Anupama; Romkes, Marjorie; Sciurba, Frank; Donahoe, Michael P; Branch, Robert A
2009-12-01
Classical drug exposure: response studies in clinical pharmacology represent the quintessential prototype for Bench to Bedside-Clinical Translational Research. A fundamental premise of this approach is for a multidisciplinary team of researchers to design and execute complex, in-depth mechanistic studies conducted in relatively small groups of subjects. The infrastructure support for this genre of clinical research is not well-handled by scaling down of infrastructure used for large Phase III clinical trials. We describe a novel, integrated strategy, whose focus is to support and manage a study using an Information Hub, Communication Hub, and Data Hub design. This design is illustrated by an application to a series of varied projects sponsored by Special Clinical Centers of Research in chronic obstructive pulmonary disease at the University of Pittsburgh. In contrast to classical informatics support, it is readily scalable to large studies. Our experience suggests the culture consequences of research group self-empowerment is not only economically efficient but transformative to the research process.
A Thin Film Multifunction Sensor for Harsh Environments
NASA Technical Reports Server (NTRS)
Wrbanek, John D.; Fralick, Gustave C.; Martin, Lisa C.; Blaha, Charles A.
2001-01-01
The status of work at NASA Glenn Research Center to develop a minimally intrusive integrated sensor to provide realtime measurement of strain, heat flux and flow in high temperature environments is presented in this paper. The sensor can be beneficial as a single package to characterize multiple stress and strain modes simultaneously on materials and components during engine development and validation. A major technical challenge is to take existing individual gauge designs and modify them into one integrated thin film sensor. Ultimately, the goal is to develop the ability to deposit the sensors directly onto internal engine parts or on a small thin substrate that can be attached to engine components. Several prototype sensors constructed of platinum, platinum-rhodium alloy, and alumina on constant-strain alumina beams have been built and bench-tested. The technical challenges of the design. construction, and testing are discussed. Data from the preliminary testing of the sensor array is presented. The future direction for the sensor development is discussed as well.
Portable thin layer chromatography for field detection of explosives and propellants
NASA Astrophysics Data System (ADS)
Satcher, Joe H.; Maienschein, Jon L.; Pagoria, Philip F.; Racoveanu, Ana; Carman, M. Leslie; Whipple, Richard E.; Reynolds, John G.
2012-06-01
A field deployable detection kit for explosives and propellants using thin layer chromatography (TLC) has been developed at Lawrence Livermore National Laboratory (LLNL). The chemistry of the kit has been modified to allow for field detection of propellants (through propellant stabilizers), military explosives, peroxide explosives, nitrates and inorganic oxidizer precursors. For many of these target analytes, the detection limit is in the μg to pg range. A new miniaturized, bench prototype, field portable TLC (Micro TLC) kit has also been developed for the detection and identification of common military explosives. It has been demonstrated in a laboratory environment and is ready for field-testing. The kit is comprised of a low cost set of commercially available components specifically assembled for rapid identification needed in the field and identifies the common military explosives: HMX, RDX, Tetryl, Explosive D or picric acid, and TNT all on one plate. Additional modifications of the Micro TLC system have been made with fluorescent organosilicon co-polymer coatings to detect a large suite of explosives.
Microbial battery for efficient energy recovery
Xie, Xing; Ye, Meng; Hsu, Po-Chun; Liu, Nian; Criddle, Craig S.; Cui, Yi
2013-01-01
By harnessing the oxidative power of microorganisms, energy can be recovered from reservoirs of less-concentrated organic matter, such as marine sediment, wastewater, and waste biomass. Left unmanaged, these reservoirs can become eutrophic dead zones and sites of greenhouse gas generation. Here, we introduce a unique means of energy recovery from these reservoirs—a microbial battery (MB) consisting of an anode colonized by microorganisms and a reoxidizable solid-state cathode. The MB has a single-chamber configuration and does not contain ion-exchange membranes. Bench-scale MB prototypes were constructed from commercially available materials using glucose or domestic wastewater as electron donor and silver oxide as a coupled solid-state oxidant electrode. The MB achieved an efficiency of electrical energy conversion of 49% based on the combustion enthalpy of the organic matter consumed or 44% based on the organic matter added. Electrochemical reoxidation of the solid-state electrode decreased net efficiency to about 30%. This net efficiency of energy recovery (unoptimized) is comparable to methane fermentation with combined heat and power. PMID:24043800
NASA Technical Reports Server (NTRS)
LEGRAND
1987-01-01
The rocket test benches are used to study burnup behavior by various methods. In the first ten months of 1966, 1578 shots were performed to test propellants, and 920 to test 14 thrust and pressure measurement projects.
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
30 CFR 57.22304 - Approved equipment (II-A mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Cutting and drilling equipment used at a face or bench shall be approved by MSHA under the applicable... feet from the face or bench being mined. (c) Tests for methane shall be conducted immediately before nonapproved equipment is taken to a face or bench after blasting. (d) Mine power transformers and stationary...
Ups and downs on spreading flanks of ocean-island volcanoes: evidence from Mauna Loa and Kīlauea
Lipman, Peter W.; Eakins, Barry W.; Yokose, Hisayoshi
2003-01-01
Submarine-flank deposits of Hawaiian volcanoes are widely recognized to have formed largely by gravitationally driven volcano spreading and associated landsliding. Observations from submersibles show that prominent benches at middepths on flanks of Mauna Loa and Kilauea consist of volcaniclastic debris derived by landsliding from nearby shallow submarine and subaerial flanks of the same edifice. Massive slide breccias from the mature subaerial tholeiitic shield of Mauna Loa underlie the frontal scarp of its South Kona bench. In contrast, coarse volcaniclastic sediments derived largely from submarine-erupted preshield alkalic and transitional basalts of ancestral Kilauea underlie its Hilina bench. Both midslope benches record the same general processes of slope failure, followed by modest compression during continued volcano spreading, even though they record development during different stages of edifice growth. The dive results suggest that volcaniclastic rocks at the north end of the Kona bench, interpreted by others as distal sediments from older volcanoes that were offscraped, uplifted, and accreted to the island by far-traveled thrusts, alternatively are a largely coherent stratigraphic assemblage deposited in a basin behind the South Kona bench.
Test bench for measurements of NOvA scintillator properties at JINR
NASA Astrophysics Data System (ADS)
Velikanova, D. S.; Antoshkin, A. I.; Anfimov, N. V.; Samoylov, O. B.
2018-04-01
The NOvA experiment was built to study oscillation parameters, mass hierarchy, CP- violation phase in the lepton sector and θ23 octant, via vɛ appearance and vμ disappearance modes in both neutrino and antineutrino beams. These scientific goals require good knowledge about NOvA scintillator basic properties. The new test bench was constructed and upgraded at JINR. The main goal of this bench is to measure scintillator properties (for solid and liquid scintillators), namely α/β discrimination and Birk's coefficients for protons and other hadrons (quenching factors). This knowledge will be crucial for recovering the energy of the hadronic part of neutrino interactions with scintillator nuclei. α/β discrimination was performed on the first version of the bench for LAB-based and NOvA scintillators. It was performed again on the upgraded version of the bench with higher statistic and precision level. Preliminary result of quenching factors for protons was obtained. A technical description of both versions of the bench and current results of the measurements and analysis are presented in this work.
Co-Production of Electricity and Hydrogen Using a Novel Iron-based Catalyst
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hilaly, Ahmad; Georgas, Adam; Leboreiro, Jose
2011-09-30
The primary objective of this project was to develop a hydrogen production technology for gasification applications based on a circulating fluid-bed reactor and an attrition resistant iron catalyst. The work towards achieving this objective consisted of three key activities: Development of an iron-based catalyst suitable for a circulating fluid-bed reactor; Design, construction, and operation of a bench-scale circulating fluid-bed reactor system for hydrogen production; Techno-economic analysis of the steam-iron and the pressure swing adsorption hydrogen production processes. This report describes the work completed in each of these activities during this project. The catalyst development and testing program prepared and iron-basedmore » catalysts using different support and promoters to identify catalysts that had sufficient activity for cyclic reduction with syngas and steam oxidation and attrition resistance to enable use in a circulating fluid-bed reactor system. The best performing catalyst from this catalyst development program was produced by a commercial catalyst toll manufacturer to support the bench-scale testing activities. The reactor testing systems used during material development evaluated catalysts in a single fluid-bed reactor by cycling between reduction with syngas and oxidation with steam. The prototype SIP reactor system (PSRS) consisted of two circulating fluid-bed reactors with the iron catalyst being transferred between the two reactors. This design enabled demonstration of the technical feasibility of the combination of the circulating fluid-bed reactor system and the iron-based catalyst for commercial hydrogen production. The specific activities associated with this bench-scale circulating fluid-bed reactor systems that were completed in this project included design, construction, commissioning, and operation. The experimental portion of this project focused on technical demonstration of the performance of an iron-based catalyst and a circulating fluid-bed reactor system for hydrogen production. Although a technology can be technically feasible, successful commercial deployment also requires that a technology offer an economic advantage over existing commercial technologies. To effective estimate the economics of this steam-iron process, a techno-economic analysis of this steam iron process and a commercial pressure swing adsorption process were completed. The results from this analysis described in this report show the economic potential of the steam iron process for integration with a gasification plant for coproduction of hydrogen and electricity.« less
Solar water disinfection (SODIS): a review from bench-top to roof-top.
McGuigan, Kevin G; Conroy, Ronán M; Mosler, Hans-Joachim; du Preez, Martella; Ubomba-Jaswa, Eunice; Fernandez-Ibañez, Pilar
2012-10-15
Solar water disinfection (SODIS) has been known for more than 30 years. The technique consists of placing water into transparent plastic or glass containers (normally 2L PET beverage bottles) which are then exposed to the sun. Exposure times vary from 6 to depending on the intensity of sunlight and sensitivity of the pathogens. Its germicidal effect is based on the combined effect of thermal heating of solar light and UV radiation. It has been repeatedly shown to be effective for eliminating microbial pathogens and reduce diarrhoeal morbidity including cholera. Since 1980 much research has been carried out to investigate the mechanisms of solar radiation induced cell death in water and possible enhancement technologies to make it faster and safer. Since SODIS is simple to use and inexpensive, the method has spread throughout the developing world and is in daily use in more than 50 countries in Asia, Latin America, and Africa. More than 5 million people disinfect their drinking water with the solar disinfection (SODIS) technique. This review attempts to revise all relevant knowledge about solar disinfection from microbiological issues, laboratory research, solar testing, up to and including real application studies, limitations, factors influencing adoption of the technique and health impact. Copyright © 2012 Elsevier B.V. All rights reserved.
Contextual interference effects on the acquisition of skill and strength of the bench press.
Naimo, Marshall A; Zourdos, Michael C; Wilson, Jacob M; Kim, Jeong-Su; Ward, Emery G; Eccles, David W; Panton, Lynn B
2013-06-01
The purpose of this study was to investigate contextual interference effects on skill acquisition and strength gains during the learning of the bench press movement. Twenty-four healthy, college-aged males and females were stratified to control, high contextual interference (HCI), and low contextual interference (LCI) groups. Treatment groups were provided with written and visual instruction on proper bench press form and practiced the bench press and dart throwing for four weeks. Within each session, LCI performed all bench press sets before undertaking dart-throws. HCI undertook dart-throws immediately following each set of bench press. Control only did testing. Measurements, including one repetition maximum (1RM), checklist scores based on video recordings of participants' 1RM's, and dart-throw test scores were taken at pre-test, 1 week, 2 week, post-test, and retention test. Results were consistent with the basic premise of the contextual interference effect. LCI had significant improvements in percent 1RM and checklist scores during training, but were mostly absent after training (post-test and retention test). HCI had significant improvements in percent 1RM and checklist scores both during and after training. Thus, HCI may augment strength and movement skill on the bench press since proper technique is an important component of resistance exercise movements. Copyright © 2013 Elsevier B.V. All rights reserved.
Effect of Fatigue Upon Performance and Electromyographic Activity in 6-RM Bench Press
van den Tillaar, Roland; Saeterbakken, Atle
2014-01-01
The aim of this study was to examine the effect of fatigue during one set of 6-RM bench pressing upon the muscle patterning and performance. Fourteen resistance-trained males (age 22.5±2.0 years, stature 1.82±0.07 m, body mass 82.0±7.8 kg) conducted a 6-RM bench press protocol. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, biceps brachii, triceps brachii, rectus abdominis, oblique external and erector spinae were measured in each repetition during the 6-RM bench press. Total lifting time increased and the velocity in the ascending movement decreased (p≤0.001). However, the kinematics in the descending phase deferred: the time decreased and velocity increased during the 6-RM (p≤0.001). Generally, muscles increased their EMG amplitude during the six repetitions in the ascending movement, while only three of the seven measured muscles showed an increase over the six repetitions in the descending part in 6-RM bench pressing. It was concluded that the bench pressing performance decreased (lower barbell velocities and longer lifting times) with increasing fatigue in the 6-RM execution. Furthermore EMG increased in the prime movers and the trunk stabilizers (abdominal and spine), while the antagonist muscle (biceps) activity was not affected by fatigue during the lifting phase in a single set of 6-RM bench pressing PMID:25031673
Effect of Fatigue Upon Performance and Electromyographic Activity in 6-RM Bench Press.
van den Tillaar, Roland; Saeterbakken, Atle
2014-03-27
The aim of this study was to examine the effect of fatigue during one set of 6-RM bench pressing upon the muscle patterning and performance. Fourteen resistance-trained males (age 22.5±2.0 years, stature 1.82±0.07 m, body mass 82.0±7.8 kg) conducted a 6-RM bench press protocol. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, biceps brachii, triceps brachii, rectus abdominis, oblique external and erector spinae were measured in each repetition during the 6-RM bench press. Total lifting time increased and the velocity in the ascending movement decreased (p≤0.001). However, the kinematics in the descending phase deferred: the time decreased and velocity increased during the 6-RM (p≤0.001). Generally, muscles increased their EMG amplitude during the six repetitions in the ascending movement, while only three of the seven measured muscles showed an increase over the six repetitions in the descending part in 6-RM bench pressing. It was concluded that the bench pressing performance decreased (lower barbell velocities and longer lifting times) with increasing fatigue in the 6-RM execution. Furthermore EMG increased in the prime movers and the trunk stabilizers (abdominal and spine), while the antagonist muscle (biceps) activity was not affected by fatigue during the lifting phase in a single set of 6-RM bench pressing.
[A man with a painful upper arm after bench press exercise].
Sijtsma, Ben C T; van der Veen, Hugo C; van Raay, Jos J A M
2015-01-01
A 22-year-old male bodybuilder presented with pain and a haematoma of his right upper arm after bench press exercises. Suspicion of a pectoralis muscle tear was confirmed by MRI and surgical repair was performed. Ruptures of the pectoralis major muscle are rare, but may occur in young male bodybuilders, typically after bench press exercises.
This report presents the results of bench-scale testing on degradation of 2,3,7,8-TCDD using W photolysis, and PCB degradation using UV photolysis, chemical oxidation and biological treatment. Bench-scale tests were conducted to investigate the feasibility of a two-phase detoxifi...
Timon, Rafael; Collado-Mateo, Daniel; Olcina, Guillermo; Gusi, Narcis
2016-03-01
Previous studies have demonstrated positive effects of acute vibration exercise on concentric strength and power, but few have observed the effects of vibration exposure on resistance training. The aim of this study was to verify the effects of whole body vibration applied to the chest via hands on bench press resistance training in trained and untrained individuals. Nineteen participants (10 recreationally trained bodybuilders and 9 untrained students) performed two randomized sessions of resistance training on separate days. Each strength session consisted of 3 bench press sets with a load of 75% 1RM to failure in each set, with 2 minutes' rest between sets. All subjects performed the same strength training with either, vibration exposure (12 Hz, 4 mm) of 30 seconds immediately before each bench press set or without vibration. Number of total repetitions, kinematic parameters, blood lactate and perceived exertion were analyzed. In the untrained group, vibration exposure caused a significant increase in the mean velocity (from 0.36±0.02 to 0.39±0.03 m/s) and acceleration (from 0.75±0.10 to 0.86±0.09 m/s2), as well as a decrease in perceived effort (from 8±0.57 to 7.35±0.47) in the first bench press set, but no change was observed in the third bench press set. In the recreationally trained bodybuilders, vibration exposure did not cause any improvement on the performance of bench press resistance training. These results suggest that vibration exposure applied just before the bench press exercise could be a good practice to be implemented by untrained individuals in resistance training.
Elbow joint fatigue and bench-press training.
Huang, Yen-Po; Chou, You-Li; Chen, Feng-Chun; Wang, Rong-Tyai; Huang, Ming-Jer; Chou, Paul Pei-Hsi
2014-01-01
Bench-press exercises are among the most common form of training exercise for the upper extremity because they yield a notable improvement in both muscle strength and muscle endurance. The literature contains various investigations into the effects of different bench-press positions on the degree of muscle activation. However, the effects of fatigue on the muscular performance and kinetics of the elbow joint are not understood fully. To investigate the effects of fatigue on the kinetics and myodynamic performance of the elbow joint in bench-press training. Controlled laboratory study. Motion research laboratory. A total of 18 physically healthy male students (age = 19.6 ± 0.8 years, height = 168.7 ± 5.5 cm, mass = 69.6 ± 8.6 kg) participated in the investigation. All participants were right-hand dominant, and none had a history of upper extremity injuries or disorders. Participants performed bench-press training until fatigued. Maximal possible number of repetitions, cycle time, myodynamic decline rate, elbow-joint force, and elbow-joint moment. We observed a difference in cycle time in the initial (2.1 ± 0.42 seconds) and fatigue (2.58 ± 0.46 seconds) stages of the bench-press exercise (P = .04). As the participants fatigued, we observed an increase in the medial-lateral force (P = .03) and internal-external moment (P ≤ .04) acting on the elbow joint. Moreover, a reduction in the elbow muscle strength was observed in the elbow extension-flexion (P ≤ .003) and forearm supination-pronation (P ≤ .001) conditions. The results suggest that performing bench-press exercises to the point of fatigue increases elbow-joint loading and may further increase the risk of injury. Therefore, when clinicians design bench-press exercise regimens for general athletic training, muscle strengthening, or physical rehabilitation, they should control carefully the maximal number of repetitions.
Dugdale, James H; Hunter, Angus; Di Virgilio, Thomas; Macgregor, Lewis J; Hamilton, D Lee
2017-02-13
This study examined the acute effects of the 'Slingshot' on bench-press performance, prime-mover surface electromyographic (sEMG) amplitude, and barbell velocity during maximal and submaximal bench-pressing in competitive male powerlifters. Fifteen male powerlifters (mean ± SD age: 27.05 ± 5.94 years; mass: 94.15kg; 1RM bench-press: 139.7 ± 16.79kg) participated in the study. Bench-press strength, average barbell velocity, and sEMG amplitude of the prime mover muscles (triceps brachii, pectoralis major and anterior deltoid) were measured during two conditions; 'Raw' (without use of any assistance) and 'Slingshot' [using the 'Slingshot' to perform both the weight achieved during 'Raw' 1RM testing (Raw max/SS), and absolute 1RM using the 'Slingshot' (SS)]. The results showed that the 'Slingshot' significantly increased bench press 1RM performance by a mean ± SD of 20.67kg ± 3.4kg. Barbell velocity and stick point analysis indicate that this improvement is likely driven by an increase in peak and pre-stick barbell velocity as triceps RMS was lower throughout all rep max phases with the 'Slingshot'. The 'Slingshot' also caused reductions in RMS, specifically of the triceps at all rep ranges but barbell velocity was better maintained in the last reps of all sets. These data indicate that the 'Slingshot' specifically de-loaded the triceps muscle throughout all rep ranges and provide assistance to maintaining barbell velocity under fatigue during later repetitions of multiple-repetition sets. The 'Slingshot' training aid could therefore be used in de-load phases of bench press training or as an over-reaching and velocity training aid.
Cotterman, Michael L; Darby, Lynn A; Skelly, William A
2005-02-01
The Smith machine (SM) (vertical motion of bar on fixed path; fixed-form exercise) and free weights (FWs) (free-form path) are commonly used strength training modes. Exercisers may need to alternate between types of equipment, depending on testing, training, rehabilitation, and/or the exercisers' goals. The purposes of this study were to compare muscle force production for SM and FWs using a 1 repetition maximum (1RM) for the parallel back squat and supine bench press exercises and to predict the 1RM for one mode from 1RM on the other mode. Men (n = 16) and women (n = 16) alternately completed 1RM testing for squat and bench press using SM and FWs. Analyses of variance (type of equipment x sex) and linear regression models were calculated. A significant difference was found between bench press and squat 1RMs for each mode of equipment for all participants. The squat 1RM was greater for the SM than the FWs; conversely, the bench 1RM was greater for FWs than the SM. When sex was considered, bench 1RM for FWs was greater than SM for men and women. The squat 1RM was greater for SM than FWs for women only. The 1RM on one mode of equipment was the best predictor of 1RM for the other mode. For both sexes, the equation SM bench 1RM (in kilograms) = -6.76 + 0.95 (FW bench 1RM) can be used. For women only, SM squat 1RM (in kilograms) = 28.3 + 0.73 (FW squat 1RM). These findings provide equations for converting between SM and FW equipment for training.
A Virtual Reality Simulator Prototype for Learning and Assessing Phaco-sculpting Skills
NASA Astrophysics Data System (ADS)
Choi, Kup-Sze
This paper presents a virtual reality based simulator prototype for learning phacoemulsification in cataract surgery, with focus on the skills required for making a cross-shape trench in cataractous lens by an ultrasound probe during the phaco-sculpting procedure. An immersive virtual environment is created with 3D models of the lens and surgical tools. Haptic device is also used as 3D user interface. Phaco-sculpting is simulated by interactively deleting the constituting tetrahedrons of the lens model. Collisions between the virtual probe and the lens are effectively identified by partitioning the space containing the lens hierarchically with an octree. The simulator can be programmed to collect real-time quantitative user data for reviewing and assessing trainee's performance in an objective manner. A game-based learning environment can be created on top of the simulator by incorporating gaming elements based on the quantifiable performance metrics.
PRELIMINARY TEST RESULTS OF A PROTOTYPE FAST KICKER FOR APS MBA UPGRADE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, C.-Y.; Morrison, L.; Sun, X.
The APS multi-bend achromatic (MBA) upgrade storage ring plans to support two bunch fill patterns: a 48-bunch and a 324-bunch. A “swap out” injection scheme is required. In order to provide the required kick to injected beam, to minimize the beam loss and residual oscillation of injected beam, and to minimize the perturbation to stored beam during injection, the rise, fall, and flat-top parts of the kicker pulse must be within a 16.9-ns interval. Stripline-type kickers are chosen for both injection and extraction. We developed a prototype kicker that supports a ±15kV differential pulse voltage. We performed high voltage discharge,more » TDR measurement, high voltage pulse test and beam test of the kicker. We report the final design of the fast kicker and the test results.« less
An engineering database management system for spacecraft operations
NASA Technical Reports Server (NTRS)
Cipollone, Gregorio; Mckay, Michael H.; Paris, Joseph
1993-01-01
Studies at ESOC have demonstrated the feasibility of a flexible and powerful Engineering Database Management System in support for spacecraft operations documentation. The objectives set out were three-fold: first an analysis of the problems encountered by the Operations team in obtaining and managing operations documents; secondly, the definition of a concept for operations documentation and the implementation of prototype to prove the feasibility of the concept; and thirdly, definition of standards and protocols required for the exchange of data between the top-level partners in a satellite project. The EDMS prototype was populated with ERS-l satellite design data and has been used by the operations team at ESOC to gather operational experience. An operational EDMS would be implemented at the satellite prime contractor's site as a common database for all technical information surrounding a project and would be accessible by the cocontractor's and ESA teams.
2012-05-15
CAPE CANAVERAL, Fla. – The prototype rover Artemis Jr. for NASA’s Regolith and Environment Science and Oxygen and Lunar Volatile Extraction, or RESOLVE, project is unpacked in a test facility behind the Operations and Checkout Building at NASA’s Kennedy Space Center in Florida and in place on top of the prototype lander. RESOLVE consists of a rover and drill provided by the Canadian Space Agency to support a NASA payload that is designed to prospect for water, ice and other lunar resources. RESOLVE also will demonstrate how future explorers can take advantage of resources at potential landing sites by manufacturing oxygen from soil. NASA will conduct field tests in July outside of Hilo, Hawaii, with equipment and concept vehicles that demonstrate how explorers might prospect for resources and make their own oxygen for survival while on other planetary bodies. For more information, visit http://www.nasa.gov/exploration/analogs/index.html. Photo credit: NASA/Dimitri Gerondidakis
The Cognition of Severe Moral Failure: A Novel Approach to the Perception of Evil
Govrin, Aner
2018-01-01
I describe the perception of evil as a categorization judgment, based on a prototype, with extensive feedback loops and top-down influences. Based on the attachment approach to moral judgment (Govrin, 2014, 2018), I suggest that the perception of evil consists of four salient features: Extreme asymmetry between victim and perpetrator; a specific perceived attitude of the perpetrator toward the victim's vulnerability; the observer's inability to understand the perpetrator's perspective; and insuperable differences between the observer and perpetrator's judgment following the incident which shake the observer no less than the event itself. I then show that the perception of evil involves a cognitive bias: The observer is almost always mistaken in his attributions of a certain state of mind to the perpetrator. The philosophical and evolutionary significance of this bias is discussed as well as suggestions for future testing of the prototype model of evil. PMID:29731732
A prototype of volume-controlled tidal liquid ventilator using independent piston pumps.
Robert, Raymond; Micheau, Philippe; Cyr, Stéphane; Lesur, Olivier; Praud, Jean-Paul; Walti, Hervé
2006-01-01
Liquid ventilation using perfluorochemicals (PFC) offers clear theoretical advantages over gas ventilation, such as decreased lung damage, recruitment of collapsed lung regions, and lavage of inflammatory debris. We present a total liquid ventilator designed to ventilate patients with completely filled lungs with a tidal volume of PFC liquid. The two independent piston pumps are volume controlled and pressure limited. Measurable pumping errors are corrected by a programmed supervisor module, which modifies the inserted or withdrawn volume. Pump independence also allows easy functional residual capacity modifications during ventilation. The bubble gas exchanger is divided into two sections such that the PFC exiting the lungs is not in contact with the PFC entering the lungs. The heating system is incorporated into the metallic base of the gas exchanger, and a heat-sink-type condenser is placed on top of the exchanger to retrieve PFC vapors. The prototype was tested on 5 healthy term newborn lambs (<5 days old). The results demonstrate the efficiency and safety of the prototype in maintaining adequate gas exchange, normal acido-basis equilibrium, and cardiovascular stability during a short, 2-hour total liquid ventilator. Airway pressure, lung volume, and ventilation scheme were maintained in the targeted range.
Home media server content management
NASA Astrophysics Data System (ADS)
Tokmakoff, Andrew A.; van Vliet, Harry
2001-07-01
With the advent of set-top boxes, the convergence of TV (broadcasting) and PC (Internet) is set to enter the home environment. Currently, a great deal of activity is occurring in developing standards (TV-Anytime Forum) and devices (TiVo) for local storage on Home Media Servers (HMS). These devices lie at the heart of convergence of the triad: communications/networks - content/media - computing/software. Besides massive storage capacity and being a communications 'gateway', the home media server is characterised by the ability to handle metadata and software that provides an easy to use on-screen interface and intelligent search/content handling facilities. In this paper, we describe a research prototype HMS that is being developed within the GigaCE project at the Telematica Instituut . Our prototype demonstrates advanced search and retrieval (video browsing), adaptive user profiling and an innovative 3D component of the Electronic Program Guide (EPG) which represents online presence. We discuss the use of MPEG-7 for representing metadata, the use of MPEG-21 working draft standards for content identification, description and rights expression, and the use of HMS peer-to-peer content distribution approaches. Finally, we outline explorative user behaviour experiments that aim to investigate the effectiveness of the prototype HMS during development.
Optical choppers with rotational elements: modeling, design and prototypes
NASA Astrophysics Data System (ADS)
Duma, Virgil-Florin; Cira, Octavian; Demian, Dorin
2017-05-01
We present a brief overview of our contributions regarding the analysis and design of optical choppers. Their applications range numerous domains, from optical sensing in radiometry or telescopes to laser manufacturing and biomedical imaging - for example for the controlled attenuation of light, the elimination of selected spectral domains, or the switching of optical paths. While these aspects are pointed out, the paper describes our analysis, modeling, and manufacturing of prototypes for choppers with: (a) wheels with windows with linear margins; (b) wheels with windows with non-linear margins (semi-circular or elliptical), outward or inward; (c) rotational shafts with different shapes, with slits or with holes. While variant (a) represents classical choppers, variant (b) represents the "eclipse" choppers that we have developed and also patented for the solution with two adjustable wheels that can produce circular windows. Variant (c), of choppers with shafts is also a patent application. Their transmission functions are discussed, for the shape of the laser pulses produced and for the attenuation coefficients obtained. While this discussion has been completed analytically for top-hat laser beams, it has been modeled using simulations for Gaussian and Bessel beams. Design, manufacturing aspects, and prototypes of the different chopper configurations complete the presentation.
Verbal messages strengthen bench press efficacy.
Wise, James B; Posner, Amy E; Walker, Gretchen L
2004-02-01
This study examined the effects of verbal messages on bench press efficacy: the confidence to lift progressively heavier weights for 1 repetition. Thirty-two women who had not bench pressed within the previous 18 months were assigned to 1 of 2 groups and exposed to 2 sources of efficacy information. First, subjects in both groups performed 10 repetitions on a fixed movement, vertical bench press machine and completed the bench press efficacy scale. Next, each group received 1 of 2 possible verbal messages. Both messages included the speaker's strength training qualifications. In addition, one message conveyed specific performance feedback while the other contained more general information. Then efficacy was measured again. Results indicated both messages strengthened efficacy. Strength professionals who work one-on-one with novice women should: (a) make sure lifters are aware of their professional qualifications, (b) provide specific feedback, and (c) profess their beliefs in the lifters' abilities to perform the exercises.
Bench press training program with attached chains for female volleyball and basketball athletes.
Burnham, Timothy R; Ruud, Jason D; McGowan, Robert
2010-02-01
Attaching chains to barbells to increase strength and power has become popular for athletes; however, little scientific evidence supports this practice. The present purpose was to compare chain training to traditional training for the bench press. Women collegiate athletes in volleyball and basketball (N = 19) participated in a 16-session bench press program. They were matched into either a Traditional or a Chain training group by 1-repetition maximum (1RM). The Traditional group performed the bench press with conventional equipment, while the Chain group trained with attached chains (5% of weight). Analysis showed a significant increase in 1RM for both groups over 16 sessions, Traditional +11.8% and Chain +17.4%. The difference between the groups was not statistically significant, but suggests the women who trained with attached chains improved their bench press more than the Traditional group.
Piezoelectric energy harvesting computer controlled test bench
NASA Astrophysics Data System (ADS)
Vázquez-Rodriguez, M.; Jiménez, F. J.; de Frutos, J.; Alonso, D.
2016-09-01
In this paper a new computer controlled (C.C.) laboratory test bench is presented. The patented test bench is made up of a C.C. road traffic simulator, C.C. electronic hardware involved in automating measurements, and test bench control software interface programmed in LabVIEW™. Our research is focused on characterizing electronic energy harvesting piezoelectric-based elements in road traffic environments to extract (or "harvest") maximum power. In mechanical to electrical energy conversion, mechanical impacts or vibrational behavior are commonly used, and several major problems need to be solved to perform optimal harvesting systems including, but no limited to, primary energy source modeling, energy conversion, and energy storage. It is described a novel C.C. test bench that obtains, in an accurate and automatized process, a generalized linear equivalent electrical model of piezoelectric elements and piezoelectric based energy store harvesting circuits in order to scale energy generation with multiple devices integrated in different topologies.
Piezoelectric energy harvesting computer controlled test bench.
Vázquez-Rodriguez, M; Jiménez, F J; de Frutos, J; Alonso, D
2016-09-01
In this paper a new computer controlled (C.C.) laboratory test bench is presented. The patented test bench is made up of a C.C. road traffic simulator, C.C. electronic hardware involved in automating measurements, and test bench control software interface programmed in LabVIEW™. Our research is focused on characterizing electronic energy harvesting piezoelectric-based elements in road traffic environments to extract (or "harvest") maximum power. In mechanical to electrical energy conversion, mechanical impacts or vibrational behavior are commonly used, and several major problems need to be solved to perform optimal harvesting systems including, but no limited to, primary energy source modeling, energy conversion, and energy storage. It is described a novel C.C. test bench that obtains, in an accurate and automatized process, a generalized linear equivalent electrical model of piezoelectric elements and piezoelectric based energy store harvesting circuits in order to scale energy generation with multiple devices integrated in different topologies.
Ohta, Masanori; Eguchi, Yasumasa; Inoue, Tomohiro; Honda, Toru; Morita, Yusaku; Konno, Yoshimasa; Yamato, Hiroshi; Kumashiro, Masaharu
2015-01-01
Work ability is partly determined by physical and mental fitness. Bench step exercise can be practiced anywhere at any time. The aim of this study was to determine the effects of a bench step exercise on work ability by examining cardiovascular risk factors and oxidative stress. Thirteen volunteers working in a warehousing industry comprised the bench step exercise group (n=7) and the control group (n=6). The participants in the step exercise group were encouraged to practice the step exercise at home for 16 weeks. The step exercise improved glucose metabolism and antioxidative capacity and increased work ability by reducing absences from work and improving the prognosis of work ability. The improvement in work ability was related to a reduction in oxidative stress. These results suggest that a bench step exercise may improve work ability by reducing cardiovascular risk factors and oxidative stress.
Graphene bolometer with thermoelectric readout and capacitive coupling to an antenna
NASA Astrophysics Data System (ADS)
Skoblin, Grigory; Sun, Jie; Yurgens, August
2018-02-01
We report on a prototype graphene radiation detector based on the thermoelectric effect. We used a split top gate to create a p-n junction in the graphene, thereby making an effective thermocouple to read out the electronic temperature in the graphene. The electronic temperature is increased due to the AC currents induced in the graphene from the incoming radiation, which is first received by an antenna and then directed to the graphene via the top-gate capacitance. With the exception of the constant DC voltages applied to the gate, the detector does not need any bias and is therefore very simple to use. The measurements showed a clear response to microwaves at 94 GHz with the signal being almost temperature independent in the 4-100 K temperature range. The optical responsivity reached ˜700 V/W.
NEMA NU-4 performance evaluation of PETbox4, a high sensitivity dedicated PET preclinical tomograph
NASA Astrophysics Data System (ADS)
Gu, Z.; Taschereau, R.; Vu, N. T.; Wang, H.; Prout, D. L.; Silverman, R. W.; Bai, B.; Stout, D. B.; Phelps, M. E.; Chatziioannou, A. F.
2013-06-01
PETbox4 is a new, fully tomographic bench top PET scanner dedicated to high sensitivity and high resolution imaging of mice. This manuscript characterizes the performance of the prototype system using the National Electrical Manufacturers Association NU 4-2008 standards, including studies of sensitivity, spatial resolution, energy resolution, scatter fraction, count-rate performance and image quality. The PETbox4 performance is also compared with the performance of PETbox, a previous generation limited angle tomography system. PETbox4 consists of four opposing flat-panel type detectors arranged in a box-like geometry. Each panel is made by a 24 × 50 pixelated array of 1.82 × 1.82 × 7 mm bismuth germanate scintillation crystals with a crystal pitch of 1.90 mm. Each of these scintillation arrays is coupled to two Hamamatsu H8500 photomultiplier tubes via a glass light guide. Volumetric images for a 45 × 45 × 95 mm field of view (FOV) are reconstructed with a maximum likelihood expectation maximization algorithm incorporating a system model based on a parameterized detector response. With an energy window of 150-650 keV, the peak absolute sensitivity is approximately 18% at the center of FOV. The measured crystal energy resolution ranges from 13.5% to 48.3% full width at half maximum (FWHM), with a mean of 18.0%. The intrinsic detector spatial resolution is 1.5 mm FWHM in both transverse and axial directions. The reconstructed image spatial resolution for different locations in the FOV ranges from 1.32 to 1.93 mm, with an average of 1.46 mm. The peak noise equivalent count rate for the mouse-sized phantom is 35 kcps for a total activity of 1.5 MBq (40 µCi) and the scatter fraction is 28%. The standard deviation in the uniform region of the image quality phantom is 5.7%. The recovery coefficients range from 0.10 to 0.93. In comparison to the first generation two panel PETbox system, PETbox4 achieves substantial improvements on sensitivity and spatial resolution. The overall performance demonstrates that the PETbox4 scanner is suitable for producing high quality images for molecular imaging based biomedical research.
Industry-academic partnerships: an approach to accelerate innovation.
Chen, Jennwood; Pickett, Timothy; Langell, Ashley; Trane, Ashley; Charlesworth, Brian; Loken, Kris; Lombardo, Sarah; Langell, John T
2016-09-01
Biotechnology companies are process-driven organizations and often struggle with their ability to innovate. Universities, on the other hand, thrive on discovery and variation as a source of innovation. As such, properly structured academic-industry partnerships in medical technology development may enhance and accelerate innovation. Through joint industry-academic efforts, our objective was to develop a technology aimed at global cervical cancer prevention. Our Center for Medical Innovation assembled a multidisciplinary team of students, surgical residents, and clinical faculty to enter in the University of Utah's annual Bench-to-Bedside competition. Bench-to-Bedside is a university program centered on medical innovation. Teams are given access to university resources and are provided $500.00 for prototype development. Participation by team members are on a volunteer basis. Our industry partner presented the validated need and business mentorship. The team studied the therapeutic landscape, environmental constraints, and used simulation to understand human factors design and usage requirements. A physical device was manufactured by first creating a digital image (SOLIDWORKS 3D CAD). Then, using a 3-dimensional printer (Stratasys Objet30 Prime 3D printer), the image was translated into a physical object. Tissue burn depth analysis was performed on raw chicken breasts warmed to room temperature. Varying combinations of time and temperature were tested, and burn depth and diameter were measured 30 min after each trial. An arithmetic mean was calculated for each corresponding time and temperature combination. User comprehension of operation and sterilization was tested via a participant validation study. Clinical obstetricians and gynecologists were given explicit instructions on usage details and then asked to operate the device. Participant behaviors and questions were recorded. Our efforts resulted in a functional battery-powered hand-held thermocoagulation prototype in just 72 d. Total cost of development was <$500. Proof of concept trials at 100°C demonstrated an average ablated depth and diameter of 4.7 mm and 23.3 mm, respectively, corresponding to treatment efficacy of all grades of precancerous cervical lesions. User comprehension studies showed variable understanding with respect to operation and sterilization instructions. Our experience with using industry-academic partnerships as a means to create medical technologies resulted in the rapid production of a low-cost device that could potentially serve as an integral piece of the "screen-and-treat" approach to premalignant cervical lesions as outlined by World Health Organization. This case study highlights the impact of accelerating medical advances through industry-academic partnership that leverages their combined resources. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Evers, Ken H.; Bachert, Robert F.
1987-01-01
The IDEAL (Integrated Design and Engineering Analysis Languages) modeling methodology has been formulated and applied over a five-year period. It has proven to be a unique, integrated approach utilizing a top-down, structured technique to define and document the system of interest; a knowledge engineering technique to collect and organize system descriptive information; a rapid prototyping technique to perform preliminary system performance analysis; and a sophisticated simulation technique to perform in-depth system performance analysis.
NASA Astrophysics Data System (ADS)
Aleksandrov, V. V.; Reyes-Romero, M.; Sidorenko, G. Yu.; Temoltzi-Auila, R.
2010-04-01
We consider the problem of choosing a test perturbation of a movable foundation of a single-link inverted pendulum so as to test a vestibular prosthesis prototype located at the top of this pendulum in an extreme situation. The obtained results permit concluding that the information transmitted from otolithic organs of the human vestibular system to muscles of the locomotor apparatus is very important and improves the quality of stabilization of the human vertical posture preventing the possible fall.
The GBT Dynamic Scheduling System: Powered by the Web
NASA Astrophysics Data System (ADS)
Marganian, P.; Clark, M.; McCarty, M.; Sessoms, E.; Shelton, A.
2009-09-01
The web technologies utilized for the Robert C. Byrd Green Bank Telescope's (GBT) new Dynamic Scheduling System are discussed, focusing on languages, frameworks, and tools. We use a popular Python web framework, TurboGears, to take advantage of the extensive web services the system provides. TurboGears is a model-view-controller framework, which aggregates SQLAlchemy, Genshi, and CherryPy respectively. On top of this framework, Javascript (Prototype, script.aculo.us, and JQuery) and cascading style sheets (Blueprint) are used for desktop-quality web pages.
Endoscopic measurements using a panoramic annular lens
NASA Technical Reports Server (NTRS)
Gilbert, John A.; Matthys, Donald R.
1992-01-01
The objective of this project was to design, build, demonstrate, and deliver a prototype system for making measurements within cavities. The system was to utilize structured lighting as the means for making measurements and was to rely on a stationary probe, equipped with a unique panoramic annular lens, to capture a cylindrical view of the illuminated cavity. Panoramic images, acquired with a digitizing camera and stored in a desk top computer, were to be linearized and analyzed by mouse-driven interactive software.
Investigation of thermal-fluid mechanical characteristics of the Capillary Pump Loop
NASA Technical Reports Server (NTRS)
Kiper, Ali M.
1991-01-01
The main purpose is the experimental and analytical study of behavior of the Capillary Pump Loop (CPL) heat pipe system during the transient mode of operating by applying a step heat pulse to one or more evaporators. Prediction of the CPL behavior when subjected to pulse heat loading requires further study before the transient response of CPL system can be fully understood. The following tasks are discussed: (1) exploratory testing of a CPL heat pipe for transient operational conditions which could generate the type of oscillatory inlet temperature behavior observed in an earlier testing of NASA/GSFC CPL-2 heat pipe system; (2) analytical investigation of the CPL inlet section temperature oscillations; (3) design, construction and testing of a bench-top CPL test system for study of the CPL transient operation; and (4) transient analysis of a CPL heat pipe by applying a step power input to the evaporators.
NASA Astrophysics Data System (ADS)
Attendu, Xavier; Crunelle, Camille; de Sivry-Houle, Martin Poinsinet; Maubois, Billie; Urbain, Joanie; Turrell, Chloe; Strupler, Mathias; Godbout, Nicolas; Boudoux, Caroline
2018-04-01
Previous works have demonstrated feasibility of combining optical coherence tomography (OCT) and hyper-spectral imaging (HSI) through a single double-clad fiber (DCF). In this proceeding we present the continued development of a system combining both modalities and capable of rapid imaging. We discuss the development of a rapidly scanning, dual-band, polygonal swept-source system which combines NIR (1260-1340 nm) and visible (450-800 nm) wavelengths. The NIR band is used for OCT imaging while visible light allows HSI. Scanning rates up to 24 kHz are reported. Furthermore, we present and discuss the fiber system used for light transport, delivery and collection, and the custom signal acquisition software. Key points include the use of a double-clad fiber coupler as well as important alignments and back-reflection management. Simultaneous and co-registered imaging with both modalities is presented in a bench-top system
Minkin, J.A.; Finkelman, R.B.; Thompson, C.L.; Chao, E.C.T.; Ruppert, L.F.; Blank, H.; Cecil, C.B.
1984-01-01
Optical and scanning electron microscope as well as electron and proton microprobe techniques have been used in a detailed investigation of the modes of occurrence of arsenic and selenium in pyrite in Upper Freeport coal from the Homer City area, Indiana County, Pennsylvania. Polished blocks were prepared from columnar samples of the coal bed to represent particular zones continuously from top to bottom. Initial selection of zones to be studied was based on chemical analysis of bench-channel samples. Microprobe data indicate that the highest concentrations of arsenic (as great as 1. 5 wt. %) are apparently in solid solution in pyrite within a limited stratigraphic interval of the coal bed. Smaller amounts of arsenic and selenium (concentrations up to approximately 0. 1 and 0. 2 wt. % respectively) were detected at isolated points within pyrite grains in various strata of the coal bed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynch, Kevin; Popp, James
This DOE grant award for was for the period June 1, 2013 to March 31, 2016. Popp was awarded an internship in the Visiting Faculty Program at FNAL in summer of 2015; consequently the unused portion of summer salary funds allowed us to apply for a no-cost extension with our remaining funds until March 31, 2017. That support furnished us with the means to carry out numerous successful projects for Mu2e for nearly four years. Up to now, the driving force to our work has been dictated primarily by the Mu2e Project cost and schedule needs. Our work has beenmore » under the purview of three of the Working Groups to which we belong: Target Station, Electron Tracker, and Stopping Target Monitor. We have carried out a mix of bench-top testing tasks locally, more elaborate work at Fermilab every summer, and extensive software development and simulation studies.« less