The treatment of idiopathic scoliosis in adolescents: rotation or in situ bending?
Gennari, J M; Tallet, J M; Hornung, H; Bergoin, M
1997-12-01
Rotation alone is not fully efficient in order to correct all types of scoliotic curvatures. We report a series of 30 cases instrumented with the EUROS spine system and analyse reductions obtained with in situ rotation or bending alone or with combined maneuvres. The average age of surgery is 17 years for this series composed of 24 female and 6 male patients. The average follow-up is 2.3 years. The curve patterns are displayed with 6 major thoracic, 5 genuine double major, 4 double major thoracic predominant, 6 double major lumbar predominant and 9 double thoracic curves. Combination of both reduction techniques is advisable and is to be made according to the type of curvature and its reducibility in situ bending is made easier with this system without lockers and by reduced diameter of the rod.
Proposed design procedure for transmission shafting under fatigue loading
NASA Technical Reports Server (NTRS)
Loewenthal, S. H.
1978-01-01
A new standard for the design of transmission shafting is reported. Computed was the diameter of rotating solid steel shafts under combined cyclic bending and steady torsion is presented. The formula is based on an elliptical variation of endurance strength with torque exhibited by combined stress fatigue data. Fatigue factors are cited to correct specimen bending endurance strength data for use in the shaft formula. A design example illustrates how the method is to be applied.
Mechanical behavior of a novel non-fusion scoliosis correction device.
Wessels, M; Hekman, E E G; Verkerke, G J
2013-11-01
We developed an innovative non-fusion correction system (XS LATOR) consisting of two individual implants that are extendable and extremely flexible. One implant, the XS LAT, generates a lateral, bending moment and one implant, the XS TOR, generates a torsion moment. Two 'inverse' implants were developed for generating torsion and lateral bending in a porcine model was tested for force delivery. An in vitro experiment was set up to describe the mechanical behavior of both implants. Narrow and wide ('inverse') versions of the XS TOR and XS LAT were mounted on an apparatus that was able to simulate different spinal geometries. The implants were anchored to three artificial vertebrae with integrated 6D force sensors, after which the vertebrae were rotated and translated towards the demanded position. The reaction forces and moments were recorded in all configurations. The maximal (lateral) bending moment, which occurred at the middle vertebra, was determined and, similarly, torque applied at the center of rotation of the middle vertebra was calculated. As expected, the wide and the small versions of the XS TOR generate a torque that increases during the growth of the system. Similarly, the XS LAT generates a bending moment that slightly increases during the growth of the system. The produced moments approximate the theoretically predicted ones. The contribution to the spinal stiffness ranges between 0.01Nm/° and 0.04Nm/° in bending and between 0.03Nm/° and 0.08Nm/° in torsion. The XS TOR and the XS LAT are able to generate a torque and a bending moment that remain (fairly) constant during spinal growth when a shape change due to the generated moment/torque is achieved. The stiffness of the implants is extremely low, being only a fraction of the stiffness of conventional, spinal fusion constructs. Current fusion systems, such as non-segmental spinal constructs generally, have 11 times higher stiffness in torsion and 6 times higher stiffness in lateral bending. Implantation of the XS LATOR adds 9% stiffness in axial rotation and 17% stiffness in lateral bending (to the original spinal stiffness). By preserving the flexibility of the spine after implantation, fusion of the vertebrae in the instrumented region is likely to be prevented. © 2013 Elsevier Ltd. All rights reserved.
Proposed design procedure for transmission shafting under fatigue loading
NASA Technical Reports Server (NTRS)
Loewenthal, S. H.
1978-01-01
The B106 American National Standards Committee is currently preparing a new standard for the design of transmission shafting. A design procedure, proposed for use in the new standard, for computing the diameter of rotating solid steel shafts under combined cyclic bending and steady torsion is presented. The formula is based on an elliptical variation of endurance strength with torque exhibited by combined stress fatigue data. Fatigue factors are cited to correct specimen bending endurance strength data for use in the shaft formula. A design example illustrates how the method is to be applied.
Urbanski, Wiktor; Wolanczyk, Michal J; Jurasz, Wojciech; Kulej, Miroslaw; Morasiewicz, Piotr; Dragan, Szymon Lukasz; Sasiadek, Marek; Dragan, Szymon Feliks
2017-07-01
Recent developments of spinal instruments allow to address nearly all components of idiopathic scoliosis. Direct vertebral rotation (DVR) maneuver was introduced to correct apical axial vertebral rotation. It is however still not well established how efficiently DVR affects results of scoliosis correction. The object of the study was to evaluate en bloc apical vertebral rotation (DVR) and its impact on coronal and sagittal correction of the spine in patients undergoing surgical scoliosis treatment. Thirty-six consecutive patients who underwent posterior spinal fusion with pedicle screws only constructs for idiopathic scoliosis. Fifteen patients (20 curves) were corrected by rod derotation only and 21 patients (26 curves) had both rod derotation and DVR. Curve measurements were performed on x-rays obtained before and postoperatively-coronal curves, kyphosis (T2-T12, T5-T12). Spine flexibility was assessed on prone bending x-rays. Apical axial rotation was determined on CT scans obtained intraoperatively and postoperatively. Rotation angle (RAsag) was measured according to Aaro and Dahlborn. We observed reduction of RAsag in all patients; however, in DVR group, decrease was greater, by 31.8% comparing to non-DVR group, by 8.6% (p = 0.0003). Mean coronal correction in DVR group was 68.8% and in rod derotation group without DVR 55% (p = 0.002). No significant correlation was found between degree of derotation obtained and coronal correction. In DVR group T2-T12 kyphosis has increased in 28 (65%) patients whereas in non-DVR group in 31 (69%) cases. Mean value of T2-T12 kyphosis growth was 16.7% in DVR and 22.1% in non-DVR group. These differences however did not occur statistically significant. Direct vertebral rotation (DVR) maneuver reduces significantly apical rotation of the spine, enhances ability of coronal correction, and it does not reduce thoracic kyphosis.
Hackenberg, Lars; Hierholzer, Eberhard; Bullmann, Viola; Liljenqvist, Ulf; Götze, Christian
2006-07-01
The forward bending test according to Adams and rib hump quantification by scoliometer are common clinical examination techniques in idiopathic scoliosis, although precise data about the change of axial surface rotation in forward bending posture are not available. In a pilot study the influence of leg length inequalities on the back shape of five normal subjects was clarified. Then 91 patients with idiopathic scoliosis with Cobb-angles between 20 degrees and 82 degrees were examined by rasterstereography, a 3D back surface analysis system. The axial back surface rotation in standing posture was compared with that in forward bending posture and additionally with a scoliometer measurement in forward bending posture. The changes of back shape in forward bending posture were correlated with the Cobb-angle, the level of the apex of the scoliotic primary curve and the age of the patient. Averaged over all patients, the back surface rotation amplitude increased from 23.1 degrees in standing to 26.3 degrees in forward bending posture. The standard deviation of this difference was high (6.1 degrees ). The correlation of back surface rotation amplitude in standing with that in forward bending posture was poor (R (2)=0.41) as was the correlation of back surface rotation in standing posture with the scoliometer in forward bending posture measured rotation (R (2)=0.35). No significant correlation could be found between the change of back shape in forward bending and the degree of deformity (R (2)=0.07), likewise no correlation with the height of the apex of the scoliosis (R (2)=0.005) and the age of the patient (R (2)=0.001). Before forward bending test leg length inequalities have to be compensated accurately. Compared to the standing posture, forward bending changes back surface rotation. However, this change varies greatly between patients, and is independent of the type and degree of scoliosis. Furthermore remarkable differences were found between scoliometer measurement of the rib hump and rasterstereographic measurement of the vertebral rotation. Therefore the forward bending test and the identification of idiopathic scoliosis rotation by scoliometer can be markedly different compared to rasterstereographic surface measurement in the standing posture.
Kim, Choll; Harris, Jonathan A; Muzumdar, Aditya; Khalil, Saif; Sclafani, Joseph A; Raiszadeh, Kamshad; Bucklen, Brandon S
2017-03-01
Lateral lumbar interbody fusion is powerful for correcting degenerative conditions, yet sagittal correction remains limited by anterior longitudinal ligament tethering. Although lordosis has been restored via ligament release, biomechanical consequences remain unknown. Investigators examined radiographic and biomechanical of ligament release for restoration of lumbar lordosis. Six fresh-frozen human cadaveric spines (L3-S1) were tested: (Miller et al., 1988) intact; (Battie et al., 1995) 8mm spacer with intact anterior longitudinal ligament; (Cho et al., 2013) 8mm spacer without intact ligament following ligament resection; (Galbusera et al., 2013) 13mm lateral lumbar interbody fusion; (Goldstein et al., 2001) integrated 13mm spacer. Focal lordosis and range of motion were assessed by applying pure moments in flexion-extension, lateral bending, and axial rotation. Cadaveric radiographs showed significant improvement in lordosis correction following ligament resection (P<0.05). The 8mm spacer with ligament construct provided greatest stability relative to intact (P>0.05) but did little to restore lordosis. Ligament release significantly destabilized the spine relative to intact in all modes and 8mm with ligament in lateral bending and axial rotation (P<0.05). Integrated lateral lumbar interbody fusion following ligament resection did not significantly differ from intact or from 8mm with ligament in all testing modes (P>0.05). Lordosis corrected by lateral lumbar interbody fusion can be improved by anterior longitudinal ligament resection, but significant construct instability and potential implant migration/dislodgment may result. This study shows that an added integrated lateral fixation system can significantly improve construct stability. Long-term multicenter studies are needed. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Makoto; Nakagawa, Akira; Chujo, Noriyuki
1996-12-01
Rotating bending fatigue tests were conducted on socket welded joints of a nominal diameter 20 mm, and effects of root defect and other various factors, including post-weld heat treatment (PWHT), pipe wall thickness, and socket wall thickness, were investigated. The socket joints exhibited, in the rotating bending fatigue mode, fatigue strengths that were markedly lower than the same 20 mm diameter joints in four-point bending fatigue. Also, where the latter specimens failed always at the toe, root-failures occurred in rotating bending fatigue. When PWHT`d, however, the fatigue strength showed a remarkable improvement, while the failure site reverted to toe. Thickermore » pipe walls and socket walls gave rise to higher fatigue strength. A formula relating the size of root defects to the fatigue strength reduction has been proposed.« less
A shell approach for fibrous reinforcement forming simulations
NASA Astrophysics Data System (ADS)
Liang, B.; Colmars, J.; Boisse, P.
2018-05-01
Because of the slippage between fibers, the basic assumptions of classical plate and shell theories are not verified by fiber reinforcement during a forming. However, simulations of reinforcement forming use shell finite elements when wrinkles development is important. A shell formulation is proposed for the forming simulations of continuous fiber reinforcements. The large tensile stiffness leads to the quasi inextensibility in the fiber directions. The fiber bending stiffness determines the curvature of the reinforcement. The calculation of tensile and bending virtual works are based on the precise geometry of the single fiber. Simulations and experiments are compared for different reinforcements. It is shown that the proposed fibrous shell approach not only correctly simulates the deflections but also the rotations of the through thickness material normals.
Hagstrum, J.T.; Gans, P.B.
1989-01-01
The Oligocene Kalamazoo Tuff (???35 Ma) was sampled for paleomagnetic analysis across a 100-km-wide zone of highly extended crust in east central Nevada to estimate between-site vertical axis rotations and thus the relative importance of strike-slip faulting to the mechanism of extension. The tilt-corrected data, with sources of error reduced or eliminated, exhibit a 28?? ?? 12?? clockwise rotation of the Schell Creek Range relative to the Kern Mountains region. This rotation implies differential extension accommodated by strike-slip faulting or N-S shortening. The paleomagnetic results also suggest that large changes in strike of layered units near faults with presumed strike-slip movement need not be the result of oroclinal bending, but could result from superimposed sets of orthogonal normal faults. -from Authors
Impact and Implementation of Higher-Order Ionospheric Effects on Precise GNSS Applications
NASA Astrophysics Data System (ADS)
Hadas, T.; Krypiak-Gregorczyk, A.; Hernández-Pajares, M.; Kaplon, J.; Paziewski, J.; Wielgosz, P.; Garcia-Rigo, A.; Kazmierski, K.; Sosnica, K.; Kwasniak, D.; Sierny, J.; Bosy, J.; Pucilowski, M.; Szyszko, R.; Portasiak, K.; Olivares-Pulido, G.; Gulyaeva, T.; Orus-Perez, R.
2017-11-01
High precision Global Navigation Satellite Systems (GNSS) positioning and time transfer require correcting signal delays, in particular higher-order ionospheric (I2+) terms. We present a consolidated model to correct second- and third-order terms, geometric bending and differential STEC bending effects in GNSS data. The model has been implemented in an online service correcting observations from submitted RINEX files for I2+ effects. We performed GNSS data processing with and without including I2+ corrections, in order to investigate the impact of I2+ corrections on GNSS products. We selected three time periods representing different ionospheric conditions. We used GPS and GLONASS observations from a global network and two regional networks in Poland and Brazil. We estimated satellite orbits, satellite clock corrections, Earth rotation parameters, troposphere delays, horizontal gradients, and receiver positions using global GNSS solution, Real-Time Kinematic (RTK), and Precise Point Positioning (PPP) techniques. The satellite-related products captured most of the impact of I2+ corrections, with the magnitude up to 2 cm for clock corrections, 1 cm for the along- and cross-track orbit components, and below 5 mm for the radial component. The impact of I2+ on troposphere products turned out to be insignificant in general. I2+ corrections had limited influence on the performance of ambiguity resolution and the reliability of RTK positioning. Finally, we found that I2+ corrections caused a systematic shift in the coordinate domain that was time- and region-dependent and reached up to -11 mm for the north component of the Brazilian stations during the most active ionospheric conditions.
NASA Astrophysics Data System (ADS)
Bhattacharyya, Sudip; Bhattacharya, Dipankar; Thampan, Arun V.
2001-08-01
We present computed spectra, as seen by a distant observer, from the accretion disc around a rapidly rotating neutron star. Our calculations are carried out in a fully general relativistic framework, with an exact treatment of rotation. We take into account the Doppler shift, gravitational redshift and light-bending effects in order to compute the observed spectrum. We find that light bending significantly modifies the high-energy part of the spectrum. Computed spectra for slowly rotating neutron stars are also presented. These results would be important for modelling the observed X-ray spectra of low-mass X-ray binaries containing fast-spinning neutron stars.
Clockwise rotation of the western Mojave Desert
NASA Technical Reports Server (NTRS)
Golombek, Matthew P.; Brown, Laurie L.
1988-01-01
A study of paleomagnetic data from Miocene volcanic rocks in the western Mojave Desert, which suggests about 25 deg of clockwise rotation, is presented. A total of 166 oriented core samples of two types of basalt were taken from 19 sites in the region. After demagnetization to 40 or 60 mT, application of structural corrections, and inversion of reversed sites, the data yielded an average direction of 51.6 deg inclination and 15.6 deg declination. When compared with the expected direction for Miocene rocks for stable North America, the direction for these Mojave rocks shows a clockwise rotation of 23.8 deg + or - 11.3 deg and a flattening of about 2.1 deg, a rotation which agrees in direction with oroclinal bending of the southern Sierra Nevada due to right-lateral shear along the western margin of North America. Most of this rotation is constrained by other paleomagnetic and strucural information to have occurred soon after the sampled basalts were deposited (about 20 Ma) and before about 16 Ma. These clockwise declination anomalies indicate that any subsequent counterclockwise rotation is small and/or compensated by previous clockwise rotation.
Jalalian, Athena; Tay, Francis Eng Hock; Arastehfar, Soheil; Gibson, Ian; Liu, Gabriel
2017-04-01
In multi-body models of scoliotic spine, personalization of mechanical properties of joints significantly improves reconstruction of the spine shape. In personalization methods based on lateral bending test, simulation of bending positions is an essential step. To simulate, a force is exerted on the spine model in the erect position. The line of action of the force affects the moment of the force about the joints and thus, if not correctly identified, causes over/underestimation of mechanical properties. Therefore, we aimed to identify the line of action, which has got little attention in previous studies. An in-depth analysis was performed on the scoliotic spine movement from the erect to four spine positions in the frontal plane by using pre-operative X-rays of 18 adolescent idiopathic scoliosis (AIS) patients. To study the movement, the spine curvature was considered as a 2D chain of micro-scale motion segments (MMSs) comprising rigid links and 1-degree-of-freedom (DOF) rotary joints. It was found that two MMSs representing the inflection points of the erect spine had almost no rotation (0.0028° ± 0.0021°) in the movement. The small rotation can be justified by weak moment of the force about these MMSs due to very small moment arm. Therefore, in the frontal plane, the line of action of the force to simulate the left/right bending position was defined as the line that passes through these MMSs in the left/right bending position. Through personalization of a 3D spine model for our patients, we demonstrated that our line of action could result in good estimates of the spine shape in the bending positions and other positions not included in the personalization, supporting our proposed line of action.
Motion analysis study on sensitivity of finite element model of the cervical spine to geometry.
Zafarparandeh, Iman; Erbulut, Deniz U; Ozer, Ali F
2016-07-01
Numerous finite element models of the cervical spine have been proposed, with exact geometry or with symmetric approximation in the geometry. However, few researches have investigated the sensitivity of predicted motion responses to the geometry of the cervical spine. The goal of this study was to evaluate the effect of symmetric assumption on the predicted motion by finite element model of the cervical spine. We developed two finite element models of the cervical spine C2-C7. One model was based on the exact geometry of the cervical spine (asymmetric model), whereas the other was symmetric (symmetric model) about the mid-sagittal plane. The predicted range of motion of both models-main and coupled motions-was compared with published experimental data for all motion planes under a full range of loads. The maximum differences between the asymmetric model and symmetric model predictions for the principal motion were 31%, 78%, and 126% for flexion-extension, right-left lateral bending, and right-left axial rotation, respectively. For flexion-extension and lateral bending, the minimum difference was 0%, whereas it was 2% for axial rotation. The maximum coupled motions predicted by the symmetric model were 1.5° axial rotation and 3.6° lateral bending, under applied lateral bending and axial rotation, respectively. Those coupled motions predicted by the asymmetric model were 1.6° axial rotation and 4° lateral bending, under applied lateral bending and axial rotation, respectively. In general, the predicted motion response of the cervical spine by the symmetric model was in the acceptable range and nonlinearity of the moment-rotation curve for the cervical spine was properly predicted. © IMechE 2016.
The Relation Between Rotation Deformity and Nerve Root Stress in Lumbar Scoliosis
NASA Astrophysics Data System (ADS)
Kim, Ho-Joong; Lee, Hwan-Mo; Moon, Seong-Hwan; Chun, Heoung-Jae; Kang, Kyoung-Tak
Even though several finite element models of lumbar spine were introduced, there has been no model including the neural structure. Therefore, the authors made the novel lumbar spine finite element model including neural structure. Using this model, we investigated the relation between the deformity pattern and nerve root stress. Two lumbar models with different types of curve pattern (lateral bending and lateral bending with rotation curve) were made. In the model of lateral bending curves without rotation, the principal compressive nerve root stress on the concave side was greater than the principal tensile stress on the convex side at the apex vertebra. Contrarily, in the lateral bending curve with rotational deformity, the nerve stress on the convex side was higher than that on the concave side. Therefore, this study elicit that deformity pattern could have significantly influence on the nerve root stress in the lumbar spine.
NASA Astrophysics Data System (ADS)
Keivani, M.; Abadian, N.; Koochi, A.; Mokhtari, J.; Abadyan, M.
2016-10-01
It has been well established that the physical performance of nanodevices might be affected by the microstructure. Herein, a two-degree-of-freedom model base on the modified couple stress theory is developed to incorporate the impact of microstructure in the torsion/bending coupled instability of rotational nanoscanner. Effect of microstructure dependency on the instability parameters is determined as a function of the microstructure parameter, bending/torsion coupling ratio, van der Waals force parameter and geometrical dimensions. It is found that the bending/torsion coupling substantially affects the stable behavior of the scanners especially those with long rotational beam elements. Impact of microstructure on instability voltage of the nanoscanner depends on coupling ratio and the conquering bending mode over torsion mode. This effect is more highlighted for higher values of coupling ratio. Depending on the geometry and material characteristics, the presented model is able to simulate both hardening behavior (due to microstructure) and softening behavior (due to torsion/bending coupling) of the nanoscanners.
Twirling and Whirling: Viscous Dynamics of Rotating Elastica
NASA Astrophysics Data System (ADS)
Wolgemuth, Charles; Powers, Thomas; Goldstein, Raymond
1999-10-01
The stability of forced elastic filaments arise in several important biological settings involving bend and twist elasticity at low Reynolds number. Examples include DNA transcription and replication and bacterial flagellar motion. In order to elucidate fundamental processes common to these systems, we consider the model problem of a rotationally forced filament with twist and bend elasticity. Competition between twist injection, twist diffusion, and writhing instabilities is described by a novel pair of PDEs for twist and bend evolution. Analytical and numerical methods elucidate the twist/bend coupling and reveal two dynamical regimes seperated by a Hopf bifurcation: (i) diffusion-dominated axial rotation, or twirling, and (ii) steady-state crankshafting motion, or whirling. Experiments are proposed to examine these phenomena and the consequences for swimming investigated.
An investigation into the kinematics of 2 cervical manipulation techniques.
Williams, Jonathan M; Cuesta-Vargas, Antonio I
2013-01-01
The purpose of this study was to quantify the kinematics of the premanipulative position, the angular displacement, and velocity of thrust of 2 commonly used cervical spine manipulative procedures using inertial sensor technology. Thirteen asymptomatic subjects (7 females; mean age, 25.3 years; mean height, 170.9 cm; mean weight, 65.3 kg) received a right-handed and left-handed downslope and upslope manipulation, aimed at C4/5 while cervical kinematics were measured using an inertial sensor mounted on the forehead of the subject. One therapist used the upslope, and another therapist, the downslope, as was their preferred method. t tests were used to compare techniques and handiness. The results demonstrated differences in the kinematics between the 2 techniques. The downslope manipulation was associated with a mean premanipulative position of 24.8° side bending and 2.7° rotation, thrust displacement magnitude comprising of 4.5° side bending and 5.4° rotation with thrust velocity comprising, on average, of 57.5°/s side bending and 74.8°/s rotation. Upslope premanipulation was on average comprised of 30.1° side bending and 8.4° rotation, thrust displacement comprised of 4.5° side bending and 12.7° rotation with thrust velocity comprising of 75.9°/s side bending and 194.7°/s rotation. The results of this study demonstrate that there are different kinematic patterns for these 2 manipulative techniques. Copyright © 2013 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Twirling and Whirling: Viscous Dynamics of Rotating Elastica
NASA Astrophysics Data System (ADS)
Powers, Thomas R.; Wolgemuth, Charles W.; Goldstein, Raymond E.
1999-11-01
Motivated by diverse phenomena in cellular biophysics, including bacterial flagellar motion and DNA transcription and replication, we study the overdamped nonlinear dynamics of a rotationally forced filament with twist and bend elasticity. The competition between twist diffusion and writhing instabilities is described by a novel pair of coupled PDEs for twist and bend evolution. Analytical and numerical methods elucidate the twist-bend coupling and reveal two dynamical regimes separated by a Hopf bifurcation: (i) diffusion-dominated axial rotation, or twirling, and (ii) steady-state crankshafting motion, or whirling. The consequences of these phenomena for self-propulsion are investigated, and experimental tests proposed.
Passive, achromatic, nearly isochronous bending system
Douglas, David R.; Yunn, Byung C.
2004-05-18
A particle beam bending system having a geometry that applies active bending only beyond the chord of the orbit for any momentum component. Using this bending configuration, all momentum components emerge dispersed in position only; all trajectories are parallel by construction. Combining a pair of such bends with reflective symmetry produces a bend cell that is, by construction, achromatic to all orders. By the particular choice of 45.degree. individual bends, a pair of such achromats can be used as the basis of a 180.degree. recirculation arc. Other rational fractions of a full 180.degree. bend serve equally well (e.g., 2 bends/cell.times.90.degree./bend.times.1 cell /arc; 2 bends/cell.times.30.degree./bend.times.3 cells/arc, etc), as do combinations of multiple bending numerologies (e.g., 2 bends/cell.times.22.5.degree./bend.times.2 cells+2 bends/cell.times.45.degree./bend.times.1 cell). By the choice of entry pole face rotation of the first magnet and exit pole face rotation of the second magnet (with a value to be determined from the particular beam stability requirements imposed by the choice of bending angle and beam properties to be used in any particular application), desirable focusing properties can be introduced and beam stability can be insured.
Head repositioning accuracy in patients with whiplash-associated disorders.
Feipel, Veronique; Salvia, Patrick; Klein, Helene; Rooze, Marcel
2006-01-15
Controlled study, measuring head repositioning error (HRE) using an electrogoniometric device. To compare HRE in neutral position, axial rotation and complex postures of patients with whiplash-associated disorders (WAD) to that of control subjects. The presence of kinesthetic alterations in patients with WAD is controversial. In 26 control subjects and 29 patients with WAD (aged 22-74 years), head kinematics was sampled using a 3-dimensional electrogoniometer mounted using a harness and a helmet. All tasks were realized in seated position. The repositioning tasks included neutral repositioning after maximal flexion-extension, eyes open and blindfolded, repositioning at 50 degrees of axial rotation, and repositioning at 50 degrees of axial rotation combined to 20 degrees of ipsilateral bending. The flexion-extension, ipsilateral bending, and axial rotation components of HRE were considered. A multiple-way repeated-measures analysis of variance was used to compare tasks and groups. The WAD group displayed a reduced flexion-extension range (P = 1.9 x 10(-4)), and larger HRE during flexion-extension and repositioning tasks (P = 0.009) than controls. Neither group nor task affected maximal motion velocity. Neutral HRE of the flexion-extension component was larger in blindfolded condition (P = 0.03). Ipsilateral bending and axial rotation HRE components were smaller than the flexion-extension component (P = 7.1 x 10(-23)). For pure rotation repositioning, axial rotation HRE was significantly larger than flexion-extension and ipsilateral bending repositioning error (P = 3.0 x 10(-23)). Ipsilateral bending component of HRE was significantly larger combined tasks than for pure rotation tasks (P = 0.004). In patients with WAD, range of motion and head repositioning accuracy were reduced. However, the differences were small. Vision suppression and task type influenced HRE.
Sung, Paul S; Danial, Pamela; Lee, Dongchul C
2016-10-01
Lateral bending is a prerequisite for various functional activities of daily life, which require combined three-dimensional motion. Even though a number of studies have evaluated spinal kinematic changes during lateral bending, the literature reveals a lack of data based on limb dominance. The purpose of this study was to compare kinematic angular displacement of the spinal regions for dominant and non-dominant lateral bending in subjects with and without recurrent low back pain. Forty-four right hand dominant individuals with recurrent low back pain (43.1 [17.4] years) and without low back pain (39.7 [18.7] years) participated in this study. All participants were asked to perform trunk lateral bending to the dominant and non-dominant sides with a bar, three times repeatedly. The outcome measures included three-dimensional angular displacements for the three regions of the spine (upper thorax, lower thorax, and lumbar spine). Lumbar rotation (degrees) increased to the dominant side in the low back pain group (9.29 [1.06]) compared to the control group (6.20 [1.02]) with increased rotation in the upper thorax as well (t=-2.09, p=0.04). However, the upper thorax rotation increased in the low back pain group to the non-dominant side (t=2.08, p=0.03) and to the dominant side (t=-2.35, p=0.02). There was a group interaction with planes (F=5.82, p=0.02) during lateral bending. Although lower thorax motion was not different between groups, increased lumbar spine and upper thorax rotations to the dominant side in the low back pain group were evident during lateral bending. This directional asymmetry should be carefully monitored to understand increased lumbar rotation to the dominant side in subjects with recurrent low back pain. The interactions between group and plane explain compensation strategies through increased lumbar rotation to the dominant side with decreased lateral bending of the upper thorax in subjects with recurrent low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.
Three-dimensional action of Chêneau brace on thoracolumbar scoliosis.
Kotwicki, Tomasz; Pietrzak, Szymon; Szulc, Andrzej
2002-01-01
We treated 18 girls for idiopathic thoracolumbar scoliosis with Chêneau brace. The apex of the curve was at Th12 or at L1 or at the disc Th12/L1. The initial Cobb angle varied from 21 to 42 degrees, mean 28. The follow up period was of 2 years and 6 months on the average. We noted the rib hump height on Adams' forward bending test. We measured Cobb angle, apical vertebra transposition and apical vertebra rotation (according to Perdriolle method) on antero-posterior standing radiograms before the treatment had started and at the moment of the best correction. We digitized antero-posterior and lateral standing radiograms with sonic digitizer GP-9 and we prepared computed reconstruction of the transversal plane of the spine with Hecquet and Graf's software RACHIS 91TM. The best clinical and radiological correction was achieved after 3 to 8 months of treatment (mean 5,5 months). We considered it as the fitting period and we analysed the correction achieved at that moment and at last follow-up. Cobb angle in brace ranged from 0 to 18 degrees, mean 9 degrees. The correction of apical vertebra transposition ranged from 51% to 100%, mean 80%. The correction of apical vertebra rotation ranged from 0% to 100%, mean 52%. The correction of rib hump ranged from 0 to 100%, mean 42%. Normal sagittal contour was established in 15 patients. important correction was present in each of the three planes.
Fatigue Properties of the Ultra-High Strength Steel TM210A
Kang, Xia; Zhao, Gui-ping
2017-01-01
This paper presents the results of an experiment to investigate the high cycle fatigue properties of the ultra-high strength steel TM210A. A constant amplitude rotating bending fatigue experiment was performed at room temperature at stress ratio R = −1. In order to evaluate the notch effect, the fatigue experiment was carried out upon two sets of specimens, smooth and notched, respectively. In the experiment, the rotating bending fatigue life was tested using the group method, and the rotating bending fatigue limit was tested using the staircase method at 1 × 107 cycles. A double weighted least square method was then used to fit the stress-life (S–N) curve. The S–N curves of the two sets of specimens were obtained and the morphologies of the fractures of the two sets of specimens were observed with scanning electron microscopy (SEM). The results showed that the fatigue limit of the smooth specimen for rotating bending fatigue was 615 MPa; the ratio of the fatigue limit to tensile strength was 0.29, and the cracks initiated at the surface of the smooth specimen; while the fatigue limit of the notched specimen for rotating bending fatigue was 363 MPa, and the cracks initiated at the edge of the notch. The fatigue notch sensitivity index of the ultra-high strength maraging steel TM210A was 0.69. PMID:28891934
Yoganandan, Narayan; Pintar, Frank A; Stemper, Brian D; Wolfla, Christopher E; Shender, Barry S; Paskoff, Glenn
2007-05-01
Aging, trauma, or degeneration can affect intervertebral kinematics. While in vivo studies can determine motions, moments are not easily quantified. Previous in vitro studies on the cervical spine have largely used specimens from older individuals with varying levels of degeneration and have shown that moment-rotation responses under lateral bending do not vary significantly by spinal level. The objective of the present in vitro biomechanical study was, therefore, to determine the coronal and axial moment-rotation responses of degeneration-free, normal, intact human cadaveric cervicothoracic spinal columns under the lateral bending mode. Nine human cadaveric cervical columns from C2 to T1 were fixed at both ends. The donors had ranged from twenty-three to forty-four years old (mean, thirty-four years) at the time of death. Retroreflective targets were inserted into each vertebra to obtain rotational kinematics in the coronal and axial planes. The specimens were subjected to pure lateral bending moment with use of established techniques. The range-of-motion and neutral zone metrics for the coronal and axial rotation components were determined at each level of the spinal column and were evaluated statistically. Statistical analysis indicated that the two metrics were level-dependent (p < 0.05). Coronal motions were significantly greater (p < 0.05) than axial motions. Moment-rotation responses were nonlinear for both coronal and axial rotation components under lateral bending moments. Each segmental curve for both rotation components was well represented by a logarithmic function (R(2) > 0.95). Range-of-motion metrics compared favorably with those of in vivo investigations. Coronal and axial motions of degeneration-free cervical spinal columns under lateral bending showed substantially different level-dependent responses. The presentation of moment-rotation corridors for both metrics forms a normative dataset for the degeneration-free cervical spines.
Ando, Kei; Kobayashi, Kazuyoshi; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Nishida, Yoshihiro; Ishiguro, Naoki; Imagama, Shiro
2018-03-29
There is little information on intraoperative neuromonitoring during correction fusion surgery for syndromic scoliosis. To investigate intraoperative TcMEPs and conditions (body temperature and blood pressure) for syndromic scoliosis. The subjects were 23 patients who underwent 25 surgeries for corrective fusion using TcMEP. Patients were divided into groups based on a decrease (DA+) or no decrease (DA-) of the amplitude of the TcMEP waveform of ≥70%. The groups were compared for age, sex, disease, type of surgery, fusion area, operation time, estimated blood loss, body temperature, blood pressure, Cobb angle, angular curve (Cobb angle/number of vertebra), bending flexibility, correction rate, and recovery. The mean Cobb angles before and after surgery were 85.2° and 29.1°, giving a correction rate of 68.2%. There were 16 surgeries (64.0%) with intraoperative TcMEP wave changes. The DA+ and DA- groups had similar intraoperative conditions, but the short angular curve differed significantly between these groups. Amplitude deterioration occurred in 4 cases during first rod placement, in 8 during rotation, and in 3 during second rod placement after rotation. Seven patients had complete loss of TcMEP. However, most TcMEP changes recovered after pediclectomy or decreased correction. The preoperative angular curve differed significantly between patients with and without TcMEP changes (P < .05). Intraoperative TcMEP wave changes occurred in 64.0% of surgeries for corrective fusion, and all but one of these changes occurred during the correction procedure. The angular curve was a risk factor for intraoperative motor deficit.
NASA Astrophysics Data System (ADS)
Gerstmayr, Johannes; Irschik, Hans
2008-12-01
In finite element methods that are based on position and slope coordinates, a representation of axial and bending deformation by means of an elastic line approach has become popular. Such beam and plate formulations based on the so-called absolute nodal coordinate formulation have not yet been verified sufficiently enough with respect to analytical results or classical nonlinear rod theories. Examining the existing planar absolute nodal coordinate element, which uses a curvature proportional bending strain expression, it turns out that the deformation does not fully agree with the solution of the geometrically exact theory and, even more serious, the normal force is incorrect. A correction based on the classical ideas of the extensible elastica and geometrically exact theories is applied and a consistent strain energy and bending moment relations are derived. The strain energy of the solid finite element formulation of the absolute nodal coordinate beam is based on the St. Venant-Kirchhoff material: therefore, the strain energy is derived for the latter case and compared to classical nonlinear rod theories. The error in the original absolute nodal coordinate formulation is documented by numerical examples. The numerical example of a large deformation cantilever beam shows that the normal force is incorrect when using the previous approach, while a perfect agreement between the absolute nodal coordinate formulation and the extensible elastica can be gained when applying the proposed modifications. The numerical examples show a very good agreement of reference analytical and numerical solutions with the solutions of the proposed beam formulation for the case of large deformation pre-curved static and dynamic problems, including buckling and eigenvalue analysis. The resulting beam formulation does not employ rotational degrees of freedom and therefore has advantages compared to classical beam elements regarding energy-momentum conservation.
Balaguier, Romain; Madeleine, Pascal; Rose-Dulcina, Kévin; Vuillerme, Nicolas
2017-01-01
The prevalence of low back disorders is dramatically high in viticulture. Field measurements that objectively quantify work exposure can provide information on the relationship between the adopted trunk postures and low back pain. The purposes of the present study were three-fold (1) to carry out a kinematics analysis of vineyard-workers’ pruning activity by extracting the duration of bending and rotation of the trunk, (2) to question separately the relationship between the duration of forward bending or trunk rotation with low back pain intensity and pressure pain sensitivity and (3) to question the relationship between the combined duration of forward bending and trunk rotation on low back pain intensity and pressure pain sensitivity. Fifteen vineyard-workers were asked to perform pruning activity for 12 minutes with a wireless triaxial accelerometer placed on their trunk. Kinematic analysis of the trunk showed that vineyard-workers spent more than 50% of the time with the trunk flexed greater than 30° and more than 20% with the trunk rotated greater than 10°. These results show that pruning activity lead to the adoption of forward bended and rotated trunk postures that could significantly increase the risk of work related musculoskeletal disorders in the low back. However, this result was mitigated by the observation of an absence of significant association between the duration of forward bending and trunk rotation with low back pain intensity or pressure pain sensitivity. Even if prospective field measurements and studies assessing the effects of low back pain confounders are needed, this field study provides new genuine information on trunk kinematics during pruning activity. PMID:28384277
Needle puncture in rabbit functional spinal units alters rotational biomechanics.
Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D
2015-04-01
An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were <3% and 1%, respectively, of moment-rotation target values. Flexibility moment targets were 0.3 N m for flexion and axial rotation and 0.15 N m for extension and lateral bending. Needle puncture caused significant (P<0.05) changes only in flexion/extension range-of-motion and neutral zone stiffness and width (N m) compared with preintervention. No. 11 blade-stab significantly increased range-of-motion in all motions, decreased neutral zone stiffness and width (N m) in flexion/extension, and increased elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.
Improved nine-node shell element MITC9i with reduced distortion sensitivity
NASA Astrophysics Data System (ADS)
Wisniewski, K.; Turska, E.
2017-11-01
The 9-node quadrilateral shell element MITC9i is developed for the Reissner-Mindlin shell kinematics, the extended potential energy and Green strain. The following features of its formulation ensure an improved behavior: 1. The MITC technique is used to avoid locking, and we propose improved transformations for bending and transverse shear strains, which render that all patch tests are passed for the regular mesh, i.e. with straight element sides and middle positions of midside nodes and a central node. 2. To reduce shape distortion effects, the so-called corrected shape functions of Celia and Gray (Int J Numer Meth Eng 20:1447-1459, 1984) are extended to shells and used instead of the standard ones. In effect, all patch tests are passed additionally for shifts of the midside nodes along straight element sides and for arbitrary shifts of the central node. 3. Several extensions of the corrected shape functions are proposed to enable computations of non-flat shells. In particular, a criterion is put forward to determine the shift parameters associated with the central node for non-flat elements. Additionally, the method is presented to construct a parabolic side for a shifted midside node, which improves accuracy for symmetric curved edges. Drilling rotations are included by using the drilling Rotation Constraint equation, in a way consistent with the additive/multiplicative rotation update scheme for large rotations. We show that the corrected shape functions reduce the sensitivity of the solution to the regularization parameter γ of the penalty method for this constraint. The MITC9i shell element is subjected to a range of linear and non-linear tests to show passing the patch tests, the absence of locking, very good accuracy and insensitivity to node shifts. It favorably compares to several other tested 9-node elements.
Biomechanical demands on posterior fusion instrumentation during lordosis restoration procedures.
Kuo, Calvin C; Martin, Audrey; Telles, Connor; Leasure, Jeremi; Iezza, Alex; Ames, Christopher; Kondrashov, Dimitriy
2016-09-01
OBJECTIVE The goal of this study was to investigate the forces placed on posterior fusion instrumentation by 3 commonly used intraoperative techniques to restore lumbar lordosis: 1) cantilever bending; 2) in situ bending; and 3) compression and/or distraction of screws along posterior fusion rods. METHODS Five cadaveric torsos were instrumented with pedicle screws at the L1-5 levels. Specimens underwent each of the 3 lordosis restoration procedures. The pedicle screw pullout force was monitored in real time via strain gauges that were mounted unilaterally at each level. The degree of correction was noted through fluoroscopic imaging. The peak loads experienced on the screws during surgery, total demand on instrumentation, and resting loads after corrective maneuvers were measured. RESULTS A mean overall lordotic correction of 10.9 ± 4.7° was achieved. No statistically significant difference in lordotic correction was observed between restoration procedures. In situ bending imparted the largest loads intraoperatively with an average of 1060 ± 599.9 N, followed by compression/distraction (971 ± 534.1 N) and cantilever bending (705 ± 413.0 N). In situ bending produced the largest total demand and postoperative loads at L-1 (1879 ± 1064.1 and 487 ± 118.8 N, respectively), which were statistically higher than cantilever bending and compression/distraction (786 ± 272.1 and 138 ± 99.2 N, respectively). CONCLUSIONS In situ bending resulted in the highest mechanical demand on posterior lumbar instrumentation, as well as the largest postoperative loads at L-1. These results suggest that the forces generated with in situ bending indicate a greater chance of intraoperative instrumentation failure and postoperative proximal pedicle screw pullout when compared with cantilever bending and/or compression/distraction options. The results are aimed at optimizing correction and fusion strategies in lordosis restoration cases.
Zander, T.; Burra, N. K.; Bergmann, G.
2007-01-01
The orthobiom™ non-fusion scoliosis correction system consists of two longitudinal rods, polyaxial pedicle screws, mobile and fixed connectors and a cross-connector. The mobile connectors can move along and around the rod, thus allowing length adaptation during growth. The aim of this study was to determine the effects of different features of this novel implant on intervertebral rotations, to calculate the movement of the mobile connectors along the rods for different loading cases and to compare the results with those of a rigid implant construct. A finite element analysis was performed using six versions (M1–M6) of a three-dimensional, nonlinear model of a spine ranging from T3 to L2. The models were loaded with pure moments of 7.5 N m in the three main anatomical planes. First, the validated intact model (M1) was studied. Then, the orthobiom™ implant system was inserted, bridging the segments between T4 and L1 (M2). The effect of pedicle screws only in every second vertebrae was investigated (M3). For comparison, three connection variations of screws and rods were investigated: (1) an implant with rigid screws and mobile connectors (M4), (2) an implant with non-locking polyaxial screws and fixed connectors (M5) and (3) a completely rigid implant construct (M6). For flexion, extension and lateral bending, intervertebral rotation was reduced at all implant levels due to the implants. A rigid implant construct (M6) and an implant with non-locking polyaxial screws and fixed connectors (M5) led to the strongest reduction of intervertebral rotation. The orthobiom™ non-fusion implant system (M2, M3) allowed much more intervertebral rotation than a rigid implant (M6). Differences in intervertebral rotations were small when polyaxial screws were placed at every second level only (M3) instead of at every level (M2). For axial rotation, intervertebral rotation was strongly reduced by a rigid implant construct (M6) and by an implant with rigid screws and mobile connectors (M4). For rotation, an implant with non-locking polyaxial screws (M2, M3, M5) led to nearly the same intervertebral rotations as in an intact spine without an implant (M1). The predicted maximum translation of the mobile connectors along the rod was 4.2 mm for extension, 3.1 mm for lateral bending, 1.6 mm for flexion and 0.8 mm for axial rotation. The movement of the connectors was highest for those closest to the ends of the rods. With rigid screws, the maximum translation was significantly reduced. This study, conducted under a load-controlled loading protocol, showed that intervertebral rotation was reduced much less by the non-fusion orthobiom™ system than by a rigid implant. The mobile connectors moved considerably along the rod when the spine was bent. It can be expected that the connectors also move along the rod as the adolescent grows, possibly leaving the discs intact until the patient is fully grown. PMID:17712575
Bending and Torsion Load Alleviator With Automatic Reset
NASA Technical Reports Server (NTRS)
delaFuente, Horacio M. (Inventor); Eubanks, Michael C. (Inventor); Dao, Anthony X. (Inventor)
1996-01-01
A force transmitting load alleviator apparatus and method are provided for rotatably and pivotally driving a member to be protected against overload torsional and bending (moment) forces. The load alleviator includes at least one bias spring to resiliently bias cam followers and cam surfaces together and to maintain them in locked engagement unless a predetermined load is exceeded whereupon a center housing is pivotal or rotational with respect to a crown assembly. This pivotal and rotational movement results in frictional dissipation of the overload force by an energy dissipator. The energy dissipator can be provided to dissipate substantially more energy from the overload force than from the bias force that automatically resets the center housing and crown assembly to the normally fixed centered alignment. The torsional and bending (moment) overload levels can designed independently of each other.
Bending stiffness of catheters and guide wires.
Wünsche, P; Werner, C; Bloss, P
2002-01-01
An important property of catheters and guide wires to assess their pushability behavior is their bending stiffness. To measure bending stiffness, a new bending module with a new clamping device was developed. This module can easily be mounted in commercially available tensile testing equipment, where bending force and deflection due to the bending force can be measured. To achieve high accuracy for the bending stiffness, the bending distance has to be measured with even higher accuracy by using a laser-scan micrometer. Measurement results of angiographic catheters and guide wires were presented and discussed. The bending stiffness shows a significant dependence on the angle of the test specimen's rotation around its length axis.
Rathjen, L; Hennecke, D K; Bock, S; Kleinstück, R
2001-05-01
This paper shows results obtained by experimental and numerical investigations concerning flow structure and heat/mass transfer in a rotating two-pass coolant channel with engine-near geometry. The smooth two passes are connected by a 180 degrees U-bend in which a 90 degrees turning vane is mounted. The influence of rotation number, Reynolds number and geometry is investigated. The results show a detailed picture of the flow field and distributions of Sherwood number ratios determined experimentally by the use of the naphthalene sublimation technique as well as Nusselt number ratios obtained from the numerical work. Especially the heat/mass transfer distributions in the bend and in the region after the bend show strong gradients, where several separation zones exist and the flow is forced to follow the turbine airfoil shape. Comparisons of numerical and experimental results show only partly good agreement.
Piezoelectric micromotor based on the structure of serial bending arms.
Tong, Jianhua; Cui, Tianhong; Shao, Peige; Wang, Liding
2003-09-01
This paper presents a new piezoelectric micromotor based on the structure of serial bending arms. Serial bending arms are composed of two piezoelectric bimorphs with one end fixed and the other end free, driven by two signals of a biased square wave with a phase difference of pi/2. The free end of a cantilever arm will move along an elliptic orbit so that the cantilever is used to drive a cylinder rotor. The rotor's end surface contacts the free end of the cantilever, resulting in the rotor's rotation. There are six serial bending arms anchored on the base. The driving mechanism of the micromotor is proposed and analyzed. A new micromotor prototype, 5 mm in diameter, has been fabricated and characterized. The maximum rotational speed reaches 325 rpm, and the output torque is about 36.5 microNm.
Steiner, Malte; Volkheimer, David; Meyers, Nicholaus; Wehner, Tim; Wilke, Hans-Joachim; Claes, Lutz; Ignatius, Anita
2015-01-01
For ex vivo measurements of fracture callus stiffness in small animals, different test methods, such as torsion or bending tests, are established. Each method provides advantages and disadvantages, and it is still debated which of those is most sensitive to experimental conditions (i.e. specimen alignment, directional dependency, asymmetric behavior). The aim of this study was to experimentally compare six different testing methods regarding their robustness against experimental errors. Therefore, standardized specimens were created by selective laser sintering (SLS), mimicking size, directional behavior, and embedding variations of respective rat long bone specimens. For the latter, five different geometries were created which show shifted or tilted specimen alignments. The mechanical tests included three-point bending, four-point bending, cantilever bending, axial compression, constrained torsion, and unconstrained torsion. All three different bending tests showed the same principal behavior. They were highly dependent on the rotational direction of the maximum fracture callus expansion relative to the loading direction (creating experimental errors of more than 60%), however small angular deviations (<15°) were negligible. Differences in the experimental results between the bending tests originate in their respective location of maximal bending moment induction. Compared to four-point bending, three-point bending is easier to apply on small rat and mouse bones under realistic testing conditions and yields robust measurements, provided low variation of the callus shape among the tested specimens. Axial compressive testing was highly sensitive to embedding variations, and therefore cannot be recommended. Although it is experimentally difficult to realize, unconstrained torsion testing was found to be the most robust method, since it was independent of both rotational alignment and embedding uncertainties. Constrained torsional testing showed small errors (up to 16.8%, compared to corresponding alignment under unconstrained torsion) due to a parallel offset between the specimens’ axis of gravity and the torsional axis of rotation. PMID:25781027
Oroclinal Bending and Mountain Uplift in the Central Andes
NASA Astrophysics Data System (ADS)
Mpodozis, C.; Arriagada, C.; Roperch, P.
2007-05-01
The large paleomagnetic database now available for the Central Andes permits a good understanding of the overall spatial and temporal variations of rotations. Mesozoic to Early Paleogene rocks along the forearc of northern Chile (23°-28°S) record significant clockwise rotations (>25°) [Arriagada et al., 2006, Tectonics, doi:10.1029/2005TC001923]. Along the forearc of southern Peru, counterclockwise rotations recorded within flat lying red-beds (Moquegua Formation) increase from about -30° at 17.5°S to - 45° at15.5°S and decrease through time from the late Eocene to the late Oligocene-early Miocene [Roperch et al., 2006, Tectonics, doi:10.1029/2005TC001882]. Recently published thermo-chronological studies show evidence for strong exhumation within Bolivian Eastern Cordillera and the Puna plateau starting in the Eocene while structural studies indicate that the majority of crustal shortening in the Eastern Cordillera occurred during the Eocene-Oligocene, although the final stages of deformation may have continued through the Early Miocene. Rotations in the Peruvian and north Chilean forearc thus occurred at the same time than deformation and exhumation/uplift within the Eastern Cordillera. In contrast Neogene forearc rocks in southern Peru and northern Chile do not show evidences of rotation but low magnitude (10°) counterclockwise rotations are usually found in mid to late Miocene rocks from the northern Altiplano. These Neogene rotations are concomitant with shortening in the Sub-Andean zone and sinistral strike-slip faulting along the eastern edge of the northern Altiplano. We interpret the rotation pattern along the southern Peru and north Chile forearc as a result of strong late Eocene- late Oligocene oroclinal bending of the Central Andes associated with shortening gradients along the Eastern Cordillera associated both with the Abancay deflection and the Arica bend. The amount and spatial distribution of pre-Neogene shortening needed to account for oroclinal bending is difficult to estimate as the rotations may be partly driven by transpression along strike slip shear zones. The large rotations strongly highlight the importance of the pre-Neogene tectonic history in the evolution of the Central Andes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, G. Barratt, E-mail: barratt@mit.edu
Franck-Condon vibrational overlap integrals for the A{sup ~1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition in acetylene have been calculated in full dimension in the harmonic normal mode basis. The calculation uses the method of generating functions first developed for polyatomic Franck-Condon factors by Sharp and Rosenstock [J. Chem. Phys. 41(11), 3453–3463 (1964)], and previously applied to acetylene by Watson [J. Mol. Spectrosc. 207(2), 276–284 (2001)] in a reduced-dimension calculation. Because the transition involves a large change in the equilibrium geometry of the electronic states, two different types of corrections to the coordinate transformation are considered to first order: corrections for axis-switchingmore » between the Cartesian molecular frames and corrections for the curvilinear nature of the normal modes at large amplitude. The angular factor in the wave function for the out-of-plane component of the trans bending mode, ν{sub 4}{sup ″}, is treated as a rotation, which results in an Eckart constraint on the polar coordinates of the bending modes. To simplify the calculation, the other degenerate bending mode, ν{sub 5}{sup ″}, is integrated in the Cartesian basis and later transformed to the constrained polar coordinate basis, restoring the conventional v and l quantum numbers. An updated A{sup ~}-state harmonic force field obtained recently in the R. W. Field research group is evaluated. The results for transitions involving the gerade vibrational modes are in qualitative agreement with experiment. Calculated results for transitions involving ungerade modes are presented in Paper II of this series [G. B. Park, J. H. Baraban, and R. W. Field, “Full dimensional Franck–Condon factors for the acetylene A{sup ~1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition. II. Vibrational overlap factors for levels involving excitation in ungerade modes,” J. Chem. Phys. 141, 134305 (2014)].« less
NASA Astrophysics Data System (ADS)
Angling, Matthew J.; Elvidge, Sean; Healy, Sean B.
2018-04-01
The standard approach to remove the effects of the ionosphere from neutral atmosphere GPS radio occultation measurements is to estimate a corrected bending angle from a combination of the L1 and L2 bending angles. This approach is known to result in systematic errors and an extension has been proposed to the standard ionospheric correction that is dependent on the squared L1 / L2 bending angle difference and a scaling term (κ). The variation of κ with height, time, season, location and solar activity (i.e. the F10.7 flux) has been investigated by applying a 1-D bending angle operator to electron density profiles provided by a monthly median ionospheric climatology model. As expected, the residual bending angle is well correlated (negatively) with the vertical total electron content (TEC). κ is more strongly dependent on the solar zenith angle, indicating that the TEC-dependent component of the residual error is effectively modelled by the squared L1 / L2 bending angle difference term in the correction. The residual error from the ionospheric correction is likely to be a major contributor to the overall error budget of neutral atmosphere retrievals between 40 and 80 km. Over this height range κ is approximately linear with height. A simple κ model has also been developed. It is independent of ionospheric measurements, but incorporates geophysical dependencies (i.e. solar zenith angle, solar flux, altitude). The global mean error (i.e. bias) and the standard deviation of the residual errors are reduced from -1.3×10-8 and 2.2×10-8 for the uncorrected case to -2.2×10-10 rad and 2.0×10-9 rad, respectively, for the corrections using the κ model. Although a fixed scalar κ also reduces bias for the global average, the selected value of κ (14 rad-1) is only appropriate for a small band of locations around the solar terminator. In the daytime, the scalar κ is consistently too high and this results in an overcorrection of the bending angles and a positive bending angle bias. Similarly, in the nighttime, the scalar κ is too low. However, in this case, the bending angles are already small and the impact of the choice of κ is less pronounced.
Alford, Timothy J; Roberts, W Eugene; Hartsfield, James K; Eckert, George J; Snyder, Ronald J
2011-05-01
Utilize American Board of Orthodontics (ABO) cast/radiographic evaluation (CRE) to compare a series of 63 consecutive patients, finished with manual wire bending (conventional) treatment, vs a subsequent series of 69 consecutive patients, finished by the same orthodontist using the SureSmile™ (SS) method. Records of 132 nonextraction patients were scored by a calibrated examiner blinded to treatment mode. Age and discrepancy index (DI) between groups were compared by t-tests. A chi-square test was used to compare for differences in sex and whether the patient was treated using braces only (no orthopedic correction). Analysis of covariance tested for differences in CRE outcomes and treatment times, with sex and DI included as covariates. A logarithmic transformation of CRE outcomes and treatment times was used because their distributions were skewed. Significance was defined as P < .05. Compared with conventional finishing, SS patients had significantly lower DI scores, less treatment time (∼7 months), and better CRE scores for first-order alignment-rotation and interproximal space closure; however, second-order root angulation (RA) was inferior. SS patients were treated in less time to better CRE scores for first-order rotation (AR) and interproximal space closure (IC) but on the average, malocclusions were less complex and second order root alignment was inferior, compared with patients finished with manual wire bending.
Alford, Timothy J.; Roberts, W. Eugene; Hartsfield, James K.; Eckert, George J.; Snyder, Ronald J.
2016-01-01
Objective Utilize American Board of Orthodontics (ABO) cast/radiographic evaluation (CRE) to compare a series of 63 consecutive patients, finished with manual wire bending (conventional) treatment, vs a subsequent series of 69 consecutive patients, finished by the same orthodontist using the SureSmile™ (SS) method. Materials and Methods Records of 132 nonextraction patients were scored by a calibrated examiner blinded to treatment mode. Age and discrepancy index (DI) between groups were compared by t-tests. A chi-square test was used to compare for differences in sex and whether the patient was treated using braces only (no orthopedic correction). Analysis of covariance tested for differences in CRE outcomes and treatment times, with sex and DI included as covariates. A logarithmic transformation of CRE outcomes and treatment times was used because their distributions were skewed. Significance was defined as P < .05. Results Compared with conventional finishing, SS patients had significantly lower DI scores, less treatment time (~7 months), and better CRE scores for first-order alignment-rotation and interproximal space closure; however, second-order root angulation (RA) was inferior. Conclusion SS patients were treated in less time to better CRE scores for first-order rotation (AR) and interproximal space closure (IC) but on the average, malocclusions were less complex and second order root alignment was inferior, compared with patients finished with manual wire bending. PMID:21261488
Design and demonstration of an acoustic right-angle bend.
Lu, Wenjia; Jia, Han; Bi, Yafeng; Yang, Yuzhen; Yang, Jun
2017-07-01
In this paper, a broadband acoustic right-angle bend device in air is designed, fabricated and experimentally characterized. Perforated panels with various hole-sizes are used to construct the bend structure. Both the simulated and experimental results verify that the acoustic beam can be rotated effectively through the acoustic bend in a wide frequency range. This model may have potential applications in some areas such as sound absorption and acoustic detection in elbow pipes.
NASA Technical Reports Server (NTRS)
Subrahmanyam, K. B.; Kaza, K. R. V.; Brown, G. V.; Lawrence, C.
1986-01-01
The coupled bending-bending-torsional equations of dynamic motion of rotating, linearly pretwisted blades are derived including large precone, second degree geometric nonlinearities and Coriolis effects. The equations are solved by the Galerkin method and a linear perturbation technique. Accuracy of the present method is verified by comparisons of predicted frequencies and steady state deflections with those from MSC/NASTRAN and from experiments. Parametric results are generated to establish where inclusion of only the second degree geometric nonlinearities is adequate. The nonlinear terms causing torsional divergence in thin blades are identified. The effects of Coriolis terms and several other structurally nonlinear terms are studied, and their relative importance is examined.
Ibrahim, T; Gabbar, O A; El-Abed, K; Hutchinson, M J; Nelson, I W
2008-11-01
Our aim in this prospective radiological study was to determine whether the flexibility rate calculated from radiographs obtained during forced traction under general anaesthesia, was better than that of fulcrum-bending radiographs before corrective surgery in predicting the extent of the available correction in patients with idiopathic scoliosis. We evaluated 33 patients with a Cobb angle > 60 degrees on a standing posteroanterior radiograph, who had been treated by posterior correction. Pre-operative standing fulcrum-bending radiographs and those with forced-traction under general anaesthesia were obtained. Post-operative standing radiographs were taken after surgical correction. The mean forced-traction flexibility rate was 55% (SD 11.3) which was significantly higher than the mean fulcrum-bending flexibility rate of 32% (SD 16.1) (p < 0.001). We found no correlation between either the forced-traction or fulcrum-bending flexibility rates and the correction rate post-operatively (p = 0.24 and p = 0.44, respectively). Radiographs obtained during forced traction under general anaesthesia were better at predicting the flexibility of the curve than fulcrum-bending radiographs in curves with a Cobb angle > 60 degrees in the standing position and may identify those patients for whom supplementary anterior surgery can be avoided.
Application of ply level analysis to flexural wave propagation
NASA Astrophysics Data System (ADS)
Valisetty, R. R.; Rehfield, L. W.
1988-10-01
A brief survey is presented of the shear deformation theories of laminated plates. It indicates that there are certain non-classical influences that affect bending-related behavior in the same way as do the transverse shear stresses. They include bending- and stretching-related section warping and the concomitant non-classical surface parallel stress contributions and the transverse normal stress. A bending theory gives significantly improved performance if these non-classical affects are incorporated. The heterogeneous shear deformations that are characteristic of laminates with highly dissimilar materials, however, require that attention be paid to the modeling of local rotations. In this paper, it is shown that a ply level analysis can be used to model such disparate shear deformations. Here, equilibrium of each layer is analyzed separately. Earlier applications of this analysis include free-edge laminate stresses. It is now extended to the study of flexural wave propagation in laminates. A recently developed homogeneous plate theory is used as a ply level model. Due consideration is given to the non-classical influences and no shear correction factors are introduced extraneously in this theory. The results for the lowest flexural mode of travelling planar harmonic waves indicate that this approach is competitive and yields better results for certain laminates.
Leahy, P Devin; Puttlitz, Christian M
2016-01-01
This study examined the cervical spine range of motion (ROM) resulting from whiplash-type hyperextension and hyperflexion type ligamentous injuries, and sought to improve the accuracy of specific diagnosis of these injuries. The study was accomplished by measurement of ROM throughout axial rotation, lateral bending, and flexion and extension, using a validated finite element model of the cervical spine that was modified to simulate hyperextension and/or hyperflexion injuries. It was found that the kinematic difference between hyperextension and hyperflexion injuries was minimal throughout the combined flexion and extension ROM measurement that is commonly used for clinical diagnosis of cervical ligamentous injury. However, the two injuries demonstrated substantially different ROM under axial rotation and lateral bending. It is recommended that other bending axes beyond flexion and extension are incorporated into clinical diagnosis of cervical ligamentous injury.
Evaluation of fatigue properties of EN31 steel heat treated using biodegradable gingili oil
NASA Astrophysics Data System (ADS)
Harichandra, B. P.; Prashanth, Mrudula; Prakash, S. V.
2016-09-01
Rotating bending fatigue is the most commonly encountered loading in most machines and machine tools. At the same time, modern literature in this area is very little. EN31 steel is a steel which is commonly used in load bearing applications which encounters fatigue loading. Further, studies on heat treated EN31 steel to improve fatigue strength is hardly reported. This paper takes this rare issue further ahead by using bio-degradable gingili oil to heat treat EN31 steel for fatigue applications. This paper reports the results of rotating bending fatigue study of EN31 steel. Fatigue tests were conducted for three conditions a) Untreated, b) Heat treated with water, and c) Heat treated with gingili oil, with cantilever loads ranging from 30% to 90% using double sided rotating bending fatigue testing machine. It is seen that EN31 steel heat treated using gingili oil has far superior fatigue properties than water treated and untreated ones, with gingili oil quenched specimen have ∼10 times more fatigue life than water quenched specimen and ∼100 times more than unquenched specimens when lower bending stresses are involved.
Fatigue criterion for the design of rotating shafts under combined stress
NASA Technical Reports Server (NTRS)
Loewenthal, S. H.
1977-01-01
A revised approach to the design of transmission shafting which considers the flexure fatigue characteristics of the shaft material under combined cyclic bending and static torsion stress is presented. A fatigue failure relation, corroborated by published combined stress test data, is presented which shows an elliptical variation of reversed bending endurance strength with static torsional stress. From this elliptical failure relations, a design formula for computing the diameter of rotating solid shafts under the most common condition of loading is developed.
Moment-rotation responses of the human lumbosacral spinal column.
Guan, Yabo; Yoganandan, Narayan; Moore, Jason; Pintar, Frank A; Zhang, Jiangyue; Maiman, Dennis J; Laud, Purushottam
2007-01-01
The objective of this study was to test the hypothesis that the human lumbosacral joint behaves differently from L1-L5 joints and provides primary moment-rotation responses under pure moment flexion and extension and left and right lateral bending on a level-by-level basis. In addition, range of motion (ROM) and stiffness data were extracted from the moment-rotation responses. Ten T12-S1 column specimens with ages ranging from 27 to 68 years (mean: 50.6+/-13.2) were tested at a load level of 4.0 N m. Nonlinear flexion and extension and left and right lateral bending moment-rotation responses at each spinal level are reported in the form of a logarithmic function. The mean ROM was the greatest at the L5-S1 level under flexion (7.37+/-3.69 degrees) and extension (4.62+/-2.56 degrees) and at the L3-L4 level under lateral bending (4.04+/-1.11 degrees). The mean ROM was the least at the L1-L2 level under flexion (2.42+/-0.90 degrees), L2-L3 level under extension (1.58+/-0.63 degrees), and L1-L2 level under lateral bending (2.50+/-0.75 degrees). The present study proved the hypothesis that L5-S1 motions are significantly greater than L1-L5 motions under flexion and extension loadings, but the hypothesis was found to be untrue under the lateral bending mode. These experimental data are useful in the improved validation of FE models, which will increase the confidence of stress analysis and other modeling applications.
Moon, Edward S; Howlett, John; Wiater, Brett P; Trumble, Thomas E
2011-04-01
Plastic deformation of the forearm is a rare injury in young adults that occurs when a slow bending or rotational force is applied to the arm, most commonly in the setting of an industrial workplace accident. There are currently no guidelines for treatment of the residual forearm deformity that often results in limitations of forearm supination and pronation. We present 2 cases demonstrating that deformity correction with single cortex, double-level osteotomies combined with rigid plate fixation and early range of motion exercise that results in good functional outcomes. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Analysis of a Circular Composite Disk Subjected to Edge Rotations and Hydrostatic Pressure
NASA Technical Reports Server (NTRS)
Oliver, Stanley T.
2004-01-01
The structural analysis results for a graphite/epoxy quasi-isotropic circular plate subjected to a forced rotation at the boundary and pressure is presented. The analysis is to support a specialized material characterization test for composite cryogenic tanks. Finite element models were used to ensure panel integrity and determine the pressure necessary to achieve a predetermined equal biaxial strain value. The displacement results due to the forced rotation at the boundary led to a detailed study of the bending stiffness matrix [D]. The variation of the bending stiffness terms as a function of angular position is presented graphically, as well as, an illustrative technique of considering the laminate as an I-beam.
NASA Technical Reports Server (NTRS)
Melton, Patrick B. (Inventor)
1989-01-01
A device is disclosed for sealing and clamping a cylindrical element which is to be attached to an object such as a wall, a pressurized vessel or another cylindrical element. The device includes a gland having an inner cylindrical wall, which is threaded at one end and is attached at a bendable end to a deformable portion, which in turn is attached to one end of a conical cantilever structure. The other end of the cantilever structure connects at a bendable area to one end of an outer cylindrical wall. The opposite end of cylindrical wall terminates in a thickened portion, the radially outer surface of which is adapted to accommodate a tool for rotating the gland. The terminal end of cylindrical wall also includes an abutment surface, which is adapted to engage a seal, which in turn engages a surface of a receiver. The receiver further includes a threaded portion for engagement with the threaded portion of gland whereby a tightening rotation of gland relative to receiver will cause relative movement between cylindrical walls and of gland. This movement causes a rotation of the conical structure and thus a bending action at bending area and at the bending end of the upper end of inner cylindrical wall. These rotational and bending actions result in a forcing of the deformable portion radially inwardly so as to contact and deform a pipe. This forcible contact creates a seal between gland and pipe, and simultaneously clamps the pipe in position.
Kotwicki, Tomasz; Dubousset, Jean; Padovani, Jean-Paul
2006-06-01
Direct comparison of the correction of scoliosis achieved by different surgical methods is usually limited by the heterogeneity of the patients analyzed (their age, curve pattern, curve magnitude, etc.). The hypothesis is that an analysis of comparable scoliotic curves treated by different implant systems could detect subtle differences in outcome. The objective of this study was therefore: (1) to measure the 3D radiological parameters of scoliotic deformity and to quantify their postoperative changes, and (2) to compare the radiographic results achieved with one anterior and one posterior instrumentation methods applied to similar curves but representing different mechanisms of correction. The clinical notes and radiographs of 46 patients operated on for adolescent idiopathic scoliosis were reviewed. The inclusion criteria consisted of: a single thoracic curve, right convex, a frontal Cobb angle minimum of 45 degrees and a maximum of 65 degrees , flexibility on a lateral bending test of more than 30%, and a Risser test value of between 1 and 4. The operative procedures were: Cotrel-Dubousset instrumentation (CDI) for 25 patients (the CD group) and correction by anterior instrumentation (Pouliquen plate) for 21 patients (the ANT group). Preoperative and postoperative long cassette standing antero-posterior and lateral radiographs were examined. The frontal and sagittal thoracic Cobb angle, apical vertebra transposition (AVT), apical vertebra rotation (AVR), lowest instrumented vertebra (LIV) tilt, C7 vertebra shift and rib cage shift (RCS) were all compared. A computed reconstruction was produced with Rachis-91 software. Vertebral axial rotation angle was evaluated throughout the spine. Postoperative assessment revealed a mean correction of the frontal Cobb angle of 37.0 degrees for the CD group and 41.0 degrees for the ANT group. The AVT operative correction was 45.8 and 42.7 mm, respectively, and AVR correction was 1.8 and 12.6 degrees , respectively. The postoperative change of the sagittal Th4-Th12 Cobb angle was not significant for any method but it was significant (P=0.05) for the CD group if the curves were divided preoperatively into hypokyphotic and normokyphotic subgroups and then analyzed separately. Computed assessment demonstrated a correction of segmental axial rotation of more than 50% in the main thoracic curve in the ANT group, significantly more than that in the CD group (P<0.001). Anterior instrumentation provided better correction of the vertebral axial rotation and of the rib hump. CD instrumentation was more powerful in translation and more specifically addressed the sagittal plane: the postoperative thoracic kyphosis angle increased in the hypokyphotic curves and slightly decreased in the normokyphotic curves.
Brantley, W A; Luebke, N H; Luebke, F L; Mitchell, J C
1994-05-01
A laboratory study was performed on Gates Glidden and Peeso drills to determine the incidence of shaft fracture when a bending deflection was superimposed on the rotating drills. Samples of sizes #1 to #6 stainless steel Gates Glidden drills, sizes #1 to #6 stainless steel and carbon steel-type P Peeso drills, and sizes #009 to #023 carbon steel-type B-1 Peeso drills from each of two manufacturers were evaluated with a unique apparatus that applied a 2-mm bending deflection while rotating the instruments. The apparatus did not restrict movement of the bur head during rotation. The test drills were rotated at 2500, 4000, and 7000 revolutions per minute, and the number of revolutions at failure was recorded. Scanning electron microscopic observations established that the stainless steel Gates Glidden and Peeso drills failed by ductile fracture, whereas the carbon steel Peeso drills failed by brittle fracture. Instrument fracture was always near the handpiece shank with this test, and the length of the fractured drills was measured from the working tip. It is recommended that this additional test be adopted to determine fatigue properties of engine-driven rotary endodontic instruments in establishing international performance standards.
Effects of five hindfoot arthrodeses on foot and ankle motion: Measurements in cadaver specimens
Zhang, Kun; Chen, Yanxi; Qiang, Minfei; Hao, Yini
2016-01-01
Single, double, and triple hindfoot arthrodeses are used to correct hindfoot deformities and relieve chronic pain. However, joint fusion may lead to dysfunction in adjacent articular surfaces. We compared range of motion in adjacent joints before and after arthrodesis to determine the effects of each procedure on joint motion. The theory of moment of couple, bending moment and balanced loading was applied to each of 16 fresh cadaver feet to induce dorsiflexion, plantarflexion, internal rotation, external rotation, inversion, and eversion. Range of motion was measured with a 3-axis coordinate measuring machine in a control foot and in feet after subtalar, talonavicular, calcaneocuboid, double, or triple arthrodesis. All arthrodeses restricted mainly internal-external rotation and inversion-eversion. The restriction in a double arthrodesis was more than that in a single arthrodesis, but that in a calcaneocuboid arthrodesis was relatively low. After triple arthrodeses, the restriction on dorsiflexion and plantarflexion movements was substantial, and internal-external rotation and inversion-eversion were almost lost. Considering that different arthrodesis procedures cause complex, three-dimensional hindfoot motion reductions, we recommend talonavicular or calcaneocuboid arthrodesis for patients with well-preserved functions of plantarflexion/dorsiflexion before operation, subtalar or calcaneocuboid arthrodesis for patients with well-preserved abduction/adduction, and talonavicular arthrodesis for patients with well-preserved eversion/inversion. PMID:27752084
Douglas, David R; Tennant, Christopher
2015-11-10
A modulated-bending recirculating system that avoids CSR-driven breakdown in emittance compensation by redistributing the bending along the beamline. The modulated-bending recirculating system includes a) larger angles of bending in initial FODO cells, thereby enhancing the impact of CSR early on in the beam line while the bunch is long, and 2) a decreased bending angle in the final FODO cells, reducing the effect of CSR while the bunch is short. The invention describes a method for controlling the effects of CSR during recirculation and bunch compression including a) correcting chromatic aberrations, b) correcting lattice and CSR-induced curvature in the longitudinal phase space by compensating T.sub.566, and c) using lattice perturbations to compensate obvious linear correlations x-dp/p and x'-dp/p.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brunet, M.; Sabourin, F.
2005-08-05
This paper is concerned with the effectiveness of triangular 3-node shell element without rotational d.o.f. and the extension to a new 4-node quadrilateral shell element called S4 with only 3 translational degrees of freedom per node and one-point integration. The curvatures are computed resorting to the surrounding elements. Extension from rotation-free triangular element to a quadrilateral element requires internal curvatures in order to avoid singular bending stiffness. Two numerical examples with regular and irregular meshes are performed to show the convergence and accuracy. Deep-drawing of a box, spring-back analysis of a U-shape strip sheet and the crash simulation of amore » beam-box complete the demonstration of the bending capabilities of the proposed rotation-free triangular and quadrilateral elements.« less
Bending wavefunctions for linear molecules
NASA Astrophysics Data System (ADS)
Hirano, Tsuneo; Nagashima, Umpei; Jensen, Per
2018-01-01
The bending motion of a linear triatomic molecule has two unique characteristics: the bending mode is doubly degenerate and only positive values of the bending angle, expressed by the bond angle supplement ρ bar , can be observed. The double degeneracy requires the wavefunction to be described as a two-dimensional oscillator. In the present work, we first review the conventional expressions based on two, symmetrically equivalent normal coordinates. Then we discuss an alternative expression for the bending wavefunction in terms of two geometrical coordinates, the bond angle supplement ρ bar (= π - τ ⩾ 0 , where τ is the bond angle) and the rotation angle χ (0 ⩽ χ < 2 π) describing rotation of the molecule around the molecular axis. In this formalism, defined for the (ρ bar , χ) polar-coordinate space with volume element ρ bar d ρ bar dχ , the one-dimensional wavefunction resulted through re-normalization for χ has zero amplitude at ρ bar = 0 , and the ro-vibrational average of the bending angle, i.e., the expectation value 〈 ρ bar 〉 , attains a non-zero, positive value for any ro-vibrational state including the vibrational ground state. This conclusion appears to cause some controversy since much conventional spectroscopic wisdom insists on 〈 ρ bar 〉 having the value zero.
Direct formulation of a 4-node hybrid shell element with rotational degrees of freedom
NASA Technical Reports Server (NTRS)
Aminpour, Mohammad A.
1990-01-01
A simple 4-node assumed-stress hybrid quadrilateral shell element with rotational or drilling degrees of freedom is formulated. The element formulation is based directly on a 4-node element. This direct formulation requires fewer computations than a similar element that is derived from an internal 8-node isoparametric element in which the midside degrees of freedom are eliminated in favor of rotational degree of freedom at the corner nodes. The formulation is based on the principle of minimum complementary energy. The membrane part of the element has 12 degrees of freedom including rotational degrees of freedom. The bending part of the element also has 12 degrees of freedom. The bending part of the quadratic variations for both in-plane and out-of-plane displacement fields and linear variations for both in-plane and out-of-plane rotation fields are assumed along the edges of the element. The element Cartesian-coordinate system is chosen such as to make the stress field invariant with respect to node numbering. The membrane part of the stress field is based on a 9-parameter equilibrating stress field, while the bending part is based on a 13-parameter equilibrating stress field. The element passes the patch test, is nearly insensitive to mesh distortion, does not lock, possesses the desirable invariance properties, has no spurious modes, and produces accurate and reliable results.
NASA Technical Reports Server (NTRS)
Stowell, Elbridge Z; Schwartz, Edward B; Houbolt, John C
1945-01-01
A theoretical investigation was made of the behavior of a cantilever beam in rotational motion about a transverse axis through the root determining the stresses, the deflections, and the accelerations that occur in the beam as a result of the arrest of motion. The equations for bending and shear stress reveal that, at a given percentage of the distance from root to tip and at a given trip velocity, the bending stresses for a particular mode are independent of the length of the beam and the shear stresses vary inversely with the length. When examined with respect to a given angular velocity instead of a given tip velocity, the equations reveal that the bending stress is proportional to the length of the beam whereas the shear stress is independent of the length. Sufficient experimental verification of the theory has previously been given in connection with another problem of the same type.
NASA Technical Reports Server (NTRS)
Muszynska, A.
1985-01-01
The operation of rotor rigs used to demonstrate various instability phenomena occurring in rotating machines is described. The instability phenomena demonstrated included oil whirl/whip antiswirl, rub, loose rotating parts, water-lubricated bearing instabilities, and cracked shaft. The rotor rigs were also used to show corrective measures for preventing instabilities. Vibrational response data from the rigs were taken with modern, computerized instrumentation. The rotor nonsynchronous perturbation rig demonstrated modal identification techniques for rotor/bearing systems. Computer-aided data acquisition and presentation, using the dynamic stiffness method, makes it possible to identify rotor and bearing parameters for low modes. The shaft mode demonstrator presented the amplified modal shape line of the shaft excited by inertia forces of unbalance (synchronous perturbation). The first three bending modes of the shaft can be demonstrated. The user-friendly software, Orbits, presented a simulation of rotor precessional motion that is characteristic of various instability phenomena. The data presentation demonstration used data measured on a turbine driven compressor train as an example of how computer aided data acquisition and presentation assists in identifying rotating machine malfunctions.
[Analysis of a three-dimensional finite element model of atlas and axis complex fracture].
Tang, X M; Liu, C; Huang, K; Zhu, G T; Sun, H L; Dai, J; Tian, J W
2018-05-22
Objective: To explored the clinical application of the three-dimensional finite element model of atlantoaxial complex fracture. Methods: A three-dimensional finite element model of cervical spine (FEM/intact) was established by software of Abaqus6.12.On the basis of this model, a three-dimensional finite element model of four types of atlantoaxial complex fracture was established: C(1) fracture (Jefferson)+ C(2) fracture (type Ⅱfracture), Jefferson+ C(2) fracture(type Ⅲfracture), Jefferson+ C(2) fracture(Hangman), Jefferson+ stable C(2) fracture (FEM/fracture). The range of motion under flexion, extension, lateral bending and axial rotation were measured and compared with the model of cervical spine. Results: The three-dimensional finite element model of four types of atlantoaxial complex fracture had the same similarity and profile.The range of motion (ROM) of different segments had different changes.Compared with those in the normal model, the ROM of C(0/1) and C(1/2) in C(1) combined Ⅱ odontoid fracture model in flexion/extension, lateral bending and rotation increased by 57.45%, 29.34%, 48.09% and 95.49%, 88.52%, 36.71%, respectively.The ROM of C(0/1) and C(1/2) in C(1) combined Ⅲodontoid fracture model in flexion/extension, lateral bending and rotation increased by 47.01%, 27.30%, 45.31% and 90.38%, 27.30%, 30.0%.The ROM of C(0/1) and C(1/2) in C(1) combined Hangman fracture model in flexion/extension, lateral bending and rotation increased by 32.68%, 79.34%, 77.62% and 60.53%, 81.20%, 21.48%, respectively.The ROM of C(0/1) and C(1/2) in C(1) combined axis fracture model in flexion/extension, lateral bending and rotation increased by 15.00%, 29.30%, 8.47% and 37.87%, 75.57%, 8.30%, respectively. Conclusions: The three-dimensional finite element model can be used to simulate the biomechanics of atlantoaxial complex fracture.The ROM of atlantoaxial complex fracture is larger than nomal model, which indicates that surgical treatment should be performed.
Control of Fan Blade Vibrations Using Piezoelectrics and Bi-Directional Telemetry
NASA Technical Reports Server (NTRS)
Provenza, Andrew J.; Morrison, Carlos R.
2011-01-01
A novel wireless device which transfers supply power through induction to rotating operational amplifiers and transmits low voltage AC signals to and from a rotating body by way of radio telemetry has been successfully demonstrated in the NASA Glenn Research Center (GRC) Dynamic Spin Test Facility. In the demonstration described herein, a rotating operational amplifier provides controllable AC power to a piezoelectric patch epoxied to the surface of a rotating Ti plate. The amplitude and phase of the sinusoidal voltage command signal, transmitted wirelessly to the amplifier, was tuned to completely suppress the 3rd bending resonant vibration of the plate. The plate's 3rd bending resonance was excited using rotating magnetic bearing excitation while it spun at slow speed in a vacuum chamber. A second patch on the opposite side of the plate was used as a sensor. This paper discusses the characteristics of this novel device, the details of a spin test, results from a preliminary demonstration, and future plans.
Turbulent wind at the equatorial segment of an operating Darrieus wind turbine blade
NASA Astrophysics Data System (ADS)
Connell, J. R.; Morris, V. R.
1989-09-01
Six turbulent wind time series, measured at equally spaced equator-height locations on a circle 3 m outside a 34-m Darrieus rotor, are analyzed to approximate the wind fluctuations experienced by the rotor. The flatwise lower root-bending stress of one blade was concurrently recorded. The wind data are analyzed in three ways: wind components that are radial and tangential to the rotation of a blade were rotationally sampled; induction and wake effects of the rotor were estimated from the six Eulerian time series; and turbulence spectra of both the measured wind and the modeled wind from the PNL theory of rotationally sampled turbulence. The wind and the rotor response are related by computing the spectral response function of the flatwise lower root-bending stress. Two bands of resonant response that surround the first and second flatwise modal frequencies shift with the rotor rotation rate.
NASA Astrophysics Data System (ADS)
Tian, Jiajin; Su, Jinpeng; Zhou, Kai; Hua, Hongxing
2018-07-01
This paper presents a general formulation for nonlinear vibration analysis of rotating beams. A modified variational method combined with a multi-segment partitioning technique is employed to derive the free and transient vibration behaviors of the rotating beams. The strain energy and kinetic energy functional are formulated based on the order truncation principle of the fully geometrically nonlinear beam theory. The Coriolis effects as well as nonlinear effects due to the coupling of bending-stretching, bending-twist and twist-stretching are taken into account. The present method relaxes the need to explicitly meet the requirements of the boundary conditions for the admissible functions, and allows the use of any linearly independent, complete basis functions as admissible functions for rotating beams. Moreover, the method is readily used to deal with the nonlinear transient vibration problems for rotating beams subjected to dynamic loads. The accuracy, convergence and efficiency of the proposed method are examined by numerical examples. The influences of Coriolis and centrifugal forces on the vibration behaviors of the beams with various hub radiuses and slenderness ratios and rotating at different angular velocities are also investigated.
Hwang, Dusun; Yoon, Dong-Jin; Kwon, Il-Bum; Seo, Dae-Cheol; Chung, Youngjoo
2010-05-10
A novel method for auto-correction of fiber optic distributed temperature sensor using anti-Stokes Raman back-scattering and its reflected signal is presented. This method processes two parts of measured signal. One part is the normal back scattered anti-Stokes signal and the other part is the reflected signal which eliminate not only the effect of local losses due to the micro-bending or damages on fiber but also the differential attenuation. Because the beams of the same wavelength are used to cancel out the local variance in transmission medium there is no differential attenuation inherently. The auto correction concept was verified by the bending experiment on different bending points. (c) 2010 Optical Society of America.
A refined mixed shear flexible finite element for the nonlinear analysis of laminated plates
NASA Technical Reports Server (NTRS)
Putcha, N. S.; Reddy, J. N.
1986-01-01
The present study is concerned with the development of a mixed shear flexible finite element with relaxed continuity for the geometrically linear and nonlinear analysis of laminated anisotropic plates. The formulation of the element is based on a refined higher-order theory. This theory satisfies the zero transverse shear stress boundary conditions on the top and bottom faces of the plate. Shear correction coefficients are not needed. The developed element consists of 11 degrees-of-freedom per node, taking into account three displacements, two rotations, and six moment resultants. An evaluation of the element is conducted with respect to the accuracy obtained in the bending of laminated anistropic rectangular plates with different lamination schemes, loadings, and boundary conditions.
Gravitropism in leafy dicot stems
NASA Technical Reports Server (NTRS)
Salisbury, F. B.
1984-01-01
In an attempt to separate plant responses to mechanical stresses from responses to gravity compensation, six treatments were automated: (1) upright stationary controls; (2) horizontal clinostat; (3) intermittent clinostat (plants upright 3.3 minutes out of every 4 minutes, horizontal and rotated once in the remaining time); (4) inversion every ten minutes (plants upside down half the time); (5) inversion and immediate return to the vertical; and (6) vertical rotation. Epinasty appeared only on clinostated and on inverted plants, both subjected to gravity compensation. The mechanics of gravitropic stem bending and the effects of a unilateral application of ethephon of gravitropic bending were also investigated.
Kwan, Mun Keong; Zeyada, Hassan E; Chan, Chris Yin Wei
2015-10-15
Prospective cohort study. To compare side bending (SB) and fulcrum bending (FB) radiographs in patients with adolescent idiopathic scoliosis (AIS) and effect of magnitude and AR curves on curve correctability. The prediction of correction using side bending flexibility (SBF) and fulcrum bending flexibility (FBF) in alternate level pedicle screw (PS) configuration and effect of curve magnitude and AR curves are not well understood. 100 AIS Lenke 1 and 2 were recruited. Curve magnitude was stratified to G1 (41°-60°), G2 (61°-80°), G3 (>80°). The main thoracic (MT) curves were subclassified to AR curves [Miyanji F, Pawelek JB, Van Valin SE, et al. Is the lumbar modifier useful in surgical decision making? Defining two distinct Lenke 1A curve patterns. Spine 2008;33:2545-51]. Preoperatively SBF and FBF were determined whereas postoperative parameters were correction rate (CR), fulcrum bending correction index (FBCI), and side bending correction index (SBCI). Correlation test were carried out between SBF, FBF versus CR for the cohort. There were 38 (G1), 42 (G2), and 20 (G3) patients. 34% were AR curves. SBF for G1, G2, and G3 were 61.3 ± 14.4, 59.2 ± 16.2 and 43.1 ± 13.1% (P = 0.000) whereas FBF for G1, G2, and G3 were 71.1 ± 16.5, 58.3 ± 18.1 and 52.7 ± 17.1% (P = 0.000). The CR was G1 (74.5 ± 11.5%), G2 (69.2 ± 12.7%), and G3 (70.2 ± 8.6%). FBCI was 1.11 ± 0.3 (G1), 1.28 ± 0.4 (G2) and 1.48 ± 0.6 for G3. SBCI was 1.26 ± 0.2 (G1), 1.50 ± 0.5 (G2), and 1.72 ± 0.4 for G3. There was strong correlation for SBF and FBF versus CR for G1 and G2. For G3, a very strong correlation was established between SBF (r = 0.846, r = 0.716) and FBF versus CR (r = 0.700, r = 0.540). AR curves demonstrated higher SBF and FBF. CR remains almost constant in G1, G2, and G3. SBCI and FBCI increase significantly in G1, G2, and G3. Correlation between SBF and FBF and CR was strong for G1, G2, and very strong for G3. AR curves showed better correctability with SB and FB films.
Method for measuring tri-axial lumbar motion angles using wearable sheet stretch sensors
Nakamoto, Hiroyuki; Yamaji, Tokiya; Ootaka, Hideo; Bessho, Yusuke; Nakamura, Ryo; Ono, Rei
2017-01-01
Background Body movements, such as trunk flexion and rotation, are risk factors for low back pain in occupational settings, especially in healthcare workers. Wearable motion capture systems are potentially useful to monitor lower back movement in healthcare workers to help avoid the risk factors. In this study, we propose a novel system using sheet stretch sensors and investigate the system validity for estimating lower back movement. Methods Six volunteers (female:male = 1:1, mean age: 24.8 ± 4.0 years, height 166.7 ± 5.6 cm, weight 56.3 ± 7.6 kg) participated in test protocols that involved executing seven types of movements. The movements were three uniaxial trunk movements (i.e., trunk flexion-extension, trunk side-bending, and trunk rotation) and four multiaxial trunk movements (i.e., flexion + rotation, flexion + side-bending, side-bending + rotation, and moving around the cranial–caudal axis). Each trial lasted for approximately 30 s. Four stretch sensors were attached to each participant’s lower back. The lumbar motion angles were estimated using simple linear regression analysis based on the stretch sensor outputs and compared with those obtained by the optical motion capture system. Results The estimated lumbar motion angles showed a good correlation with the actual angles, with correlation values of r = 0.68 (SD = 0.35), r = 0.60 (SD = 0.19), and r = 0.72 (SD = 0.18) for the flexion-extension, side bending, and rotation movements, respectively (all P < 0.05). The estimation errors in all three directions were less than 3°. Conclusion The stretch sensors mounted on the back provided reasonable estimates of the lumbar motion angles. The novel motion capture system provided three directional angles without capture space limits. The wearable system possessed great potential to monitor the lower back movement in healthcare workers and helping prevent low back pain. PMID:29020053
NASA Astrophysics Data System (ADS)
Imhan, Khalil Ibraheem; Baharudin, B. T. H. T.; Zakaria, Azmi; Ismail, Mohd Idris Shah B.; Alsabti, Naseer Mahdi Hadi; Ahmad, Ahmad Kamal
2018-02-01
Laser forming is a flexible control process that has a wide spectrum of applications; particularly, laser tube bending. It offers the perfect solution for many industrial fields, such as aerospace, engines, heat exchangers, and air conditioners. A high power pulsed Nd-YAG laser with a maximum average power of 300 W emitting at 1064 nm and fiber-coupled is used to irradiate stainless steel 304 (SS304) tubes of 12.7 mm diameter, 0.6 mm thickness and 70 mm length. Moreover, a motorized rotation stage with a computer controller is employed to hold and rotate the tube. In this paper, an experimental investigation is carried out to improve the laser tube bending process by enhancing the absorption coefficient of the material and the mechanical formability using laser softening heat treatment. The material surface is coated with an oxidization layer; hence, the material absorption of laser light is increased and the temperature rapidly rises. The processing speed is enhanced and the output bending angle is increased to 1.9° with an increment of 70% after the laser softening heat treatment.
The effect of in situ augmentation on implant anchorage in proximal humeral head fractures.
Unger, Stefan; Erhart, Stefanie; Kralinger, Franz; Blauth, Michael; Schmoelz, Werner
2012-10-01
Fracture fixation in patients suffering from osteoporosis is difficult as sufficient implant anchorage is not always possible. One method to enhance implant anchorage is implant/screw augmentation with PMMA-cement. The present study investigated the feasibility of implant augmentation with PMMA-cement to enhance implant anchorage in the proximal humerus. A simulated three part humeral head fracture was stabilised with an angular stable plating system in 12 pairs of humeri using six head screws. In the augmentation group the proximal four screws were treated with four cannulated screws, each augmented with 0.5ml of PMMA-cement, whereas the contra lateral side served as a non-augmented control. Specimens were loaded in varus-bending or axial-rotation using a cyclic loading protocol with increasing load magnitude until failure of the osteosynthesis occurred. Augmented specimens showed a significant higher number of load cycles until failure than non-augment specimens (varus-bending: 8516 (SD 951.6) vs. 5583 (SD 2273.6), P=0.014; axial-rotation: 3316 (SD 348.8) vs. 2050 (SD 656.5), P=0.003). Non-augmented specimens showed a positive correlation of load cycles until failure and measured bone mineral density (varus-bending: r=0.893, P=0.016; axial-rotation: r=0.753, P=0.084), whereas no correlation was present in augmented specimens (varus-bending: r=0,258, P=0.621; axial-rotation r=0.127, P=0.810). These findings suggest that augmentation of cannulated screws is a feasible method to enhance implant/screw anchorage in the humeral head. The improvement of screw purchase is increasing with decreasing bone mineral density. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Mokhtar, Md Asjad; Kamalakar Darpe, Ashish; Gupta, Kshitij
2017-08-01
The ever-increasing need of highly efficient rotating machinery causes reduction in the clearance between rotating and non-rotating parts and increase in the chances of interaction between these parts. The rotor-stator contact, known as rub, has always been recognized as one of the potential causes of rotor system malfunctions and a source of secondary failures. It is one of few causes that influence both lateral and torsional vibrations. In this paper, the rotor stator interaction phenomenon is investigated in the finite element framework using Lagrange multiplier based contact mechanics approach. The stator is modelled as a beam that can respond to axial penetration and lateral friction force during the contact with the rotor. It ensures dynamic stator contact boundary and more realistic contact conditions in contrast to most of the earlier approaches. The rotor bending-torsional mode coupling during contact is considered and the vibration response in bending and torsion are analysed. The effect of parameters such as clearance, friction coefficient and stator stiffness are studied at various operating speeds and it has been found that certain parameter values generate peculiar rub related features. Presence of sub-harmonics in the lateral vibration frequency spectra are prominently observed when the rotor operates near the integer multiple of its lateral critical speed. The spectrum cascade of torsional vibration shows the presence of bending critical speed along with the larger amplitudes of frequencies close to torsional natural frequency of the rotor. When m × 1/n X frequency component of rotational frequency comes closer to the torsional natural frequency, stronger torsional vibration amplitude is noticed in the spectrum cascade. The combined information from the stator vibration and rotor lateral-torsional vibration spectral features is proposed for robust rub identification.
NASA Technical Reports Server (NTRS)
Heath, J. R.; Saykally, R. J.
1991-01-01
The first characterization of the bending potential of the C7 cluster is reported via the observation of the v = 1(1) and v = 2 deg levels of the nu11 (pi u) bend as hot bands associated with the nu4 (sigma u) antisymmetric stretch fundamental. The lower state hot band rotational constants are measured to be 1004.4(1.3) and 1123.6(9.0) MHz, constituting a 9.3 and 22 percent increase over the ground state rotational constant, 918.89 (41) MHz. These large increases are strong quartic and sextic centrifugal distortion constants determined for the ground and nu 4 = 1 states are found to be anomalously large and negative, evidencing strong perturbations between stretching and bending modes.
Nastic response of maize (Zea mays L.) coleoptiles during clinostat rotation.
Nick, P; Schafer, E
1989-08-01
Rotation of unstimulated maize (Zea mays L.) seedlings on a horizontal clinostat is accompanied by a strong bending response of the coleoptiles towards the caryopsis, yielding curvatures exceding 100 degrees. The corresponding azimuthal distribution shows two peaks, each of which is displayed by 30 degrees from the symmetry axis connecting the shortest coleoptile and caryopsis cross sections. It is argued that this spatial pattern is not the result of two independent bending preferences, but caused by a one-peaked distribution encountering an obstacle in its central part and thus being split into the two subpeaks. The existence of one preferential direction justifies considering this response to be a nastic movement. Its time course consists of an early negative phase (coleoptiles bend away from the caryopsis) followed 2 h later by a long-lasting positive bending towards the caryopsis. In light-interaction experiments, fluence-response curves for different angles between blue light and the direction of the nastic response were measured. These experiments indicate that blue light interacts with the nastic response at two levels: (i) phototonic inhibition, and (ii) addition of nastic and phototropic curvatures. It is concluded that phototropic and phototonic transduction bifurcate before the formation of phototropic transverse polarity. The additivity of nastic and phototropic responses was followed at the population level. At the level of the individual seedling, one observes, in the case of phototropic induction opposing nastic movement, three distinct responses: either strong phototropism, or nastic bending, or an "avoidance" response which involves strong curvature perpendicular to the stimulation plane. With time the nastic bending becomes increasingly stable against opposing phototropic stimulation. This can be seen from a growing proportion of seedlings exhibiting nastic bending when light is applied at variable intervals after the onset of clinostat rotation. At the transition from instability to stability, this type of experiment produces a high percentage of seedlings displaying the "avoidance" response. However, no cancelling resulting in zero curvature can be observed. It is concluded that the endogenous polarity underlying the nastic response is different in its very nature from the blue-light-elicited stable transverse polarity described earlier (Nick and Schafer 1988b).
Nonlinear flap-lag-axial equations of a rotating beam with arbitrary precone angle
NASA Technical Reports Server (NTRS)
Kvaternik, R. G.; White, W. F., Jr.; Kaza, K. R. V.
1978-01-01
In an attempt both to unify and extend the analytical basis of several aspects of the dynamic behavior of flexible rotating beams, the second-degree nonlinear equations of motion for the coupled flapwise bending, lagwise bending, and axial extension of an untwisted, torsionally rigid, nonuniform, rotating beam having an arbitrary angle of precone with the plane perpendicular to the axis of rotation are derived using Hamilton's principle. The derivation of the equations is based on the geometric nonlinear theory of elasticity and the resulting equations are consistent with the assumption that the strains are negligible compared to unity. No restrictions are imposed on the relative displacements or angular rotations of the cross sections of the beam other than those implied by the assumption of small strains. Illustrative numerical results, obtained by using an integrating matrix as the basis for the method of solution, are presented both for the purpose of validating the present method of solution and indicating the range of applicability of the equations of motion and the method of solution.
Three-dimensional analysis of cervical spine segmental motion in rotation.
Zhao, Xiong; Wu, Zi-Xiang; Han, Bao-Jun; Yan, Ya-Bo; Zhang, Yang; Lei, Wei
2013-06-20
The movements of the cervical spine during head rotation are too complicated to measure using conventional radiography or computed tomography (CT) techniques. In this study, we measure three-dimensional segmental motion of cervical spine rotation in vivo using a non-invasive measurement technique. Sixteen healthy volunteers underwent three-dimensional CT of the cervical spine during head rotation. Occiput (Oc) - T1 reconstructions were created of volunteers in each of 3 positions: supine and maximum left and right rotations of the head with respect to the bosom. Segmental motions were calculated using Euler angles and volume merge methods in three major planes. Mean maximum axial rotation of the cervical spine to one side was 1.6° to 38.5° at each level. Coupled lateral bending opposite to lateral bending was observed in the upper cervical levels, while in the subaxial cervical levels, it was observed in the same direction as axial rotation. Coupled extension was observed in the cervical levels of C5-T1, while coupled flexion was observed in the cervical levels of Oc-C5. The three-dimensional cervical segmental motions in rotation were accurately measured with the non-invasive measure. These findings will be helpful as the basis for understanding cervical spine movement in rotation and abnormal conditions. The presented data also provide baseline segmental motions for the design of prostheses for the cervical spine.
Zhen, Peng-Chao; Zhu, Li-Guo; Gao, Jing-Hua; Yu, Jie; Feng, Min-Shan; Wei, Xu; Wang, Shang-Quan
2010-10-01
To observe the effects of two different therapies on patients whose cervical function were restricted due to cervical spondylotic radiculopathy. Form April 2008 to October 2009, 71 cases with cervical spondylotic radiculopathy were divided into group A (36 cases) and group B (35 cases). Among them, 22 cases were male and 49 cases were female, ranging in age form 45 to 65 years with an average of 52.27 years, course of disease was from 3 days to 5 years. The patients in group A were treated with rotation-traction manipulation, neck pain particles and cervical rehabilitation exercises; and the patients in group B were treated with cervical traction, Diclofenac sodium sustained release tablets and wearing neck collar. Theapeutic time was two weeks. The cervical anteflexion, extension, left and right lateral bending, left and right rotative activity were measured by helmet-style activities instrument before and after treatment (at the 1, 3, 5, 7, 9, 11, 13 days and 1 month after treatment respectively). There were no difference between two groups in cervical activity in all directions before treatment (P > 0.05). Compared with the beginning, cervical anteflexion and extension showed significant difference at the 5th day after treatment in group A (P < 0.01). In group B, cervical anteflexion showed significant difference at the 13th day after treatment (P < 0.05), but at the 1 month after treatment, the significant difference disappeared (P > 0.05); cervical extension showed significant difference at the 7th day after treatment compared with the beginning (P < 0.05). Compared with the beginning,left lateral bending showed significant difference at the 1st day after treatment in group A (P < 0.05) and at the 5th day after treatment in group B (P < 0.01). Both in group A or B, right lateral bending, left and right rotative activity showed significant difference at the same time after treatment, either the 3rd day (P < 0.05) or the 5th day (P < 0.05). Compared between groups, cervical anteflexion, left and right lateral bending, left and right rotative activity showed significant difference at the 1 month after treatment (P < 0.05). The rotation-traction manipulation and neck pain particles and cervical rehabilitation exercises in treating cervicalspondylotic radiculopathy have quick effect to improve the activities of cervical anteflexion, extension, left lateral bending, and have durable effect to improve the activities of cervical spine in all directions.
Moment arms of the human neck muscles in flexion, bending and rotation.
Ackland, David C; Merritt, Jonathan S; Pandy, Marcus G
2011-02-03
There is a paucity of data available for the moment arms of the muscles of the human neck. The objective of the present study was to measure the moment arms of the major cervical spine muscles in vitro. Experiments were performed on five fresh-frozen human head-neck specimens using a custom-designed robotic spine testing apparatus. The testing apparatus replicated flexion-extension, lateral bending and axial rotation of each individual intervertebral joint in the cervical spine while all other joints were kept immobile. The tendon excursion method was used to measure the moment arms of 30 muscle sub-regions involving 13 major muscles of the neck about all three axes of rotation of each joint for the neutral position of the cervical spine. Significant differences in the moment arm were observed across sub-regions of individual muscles and across the intervertebral joints spanned by each muscle (p<0.05). Overall, muscle moment arms were larger in flexion-extension and lateral bending than in axial rotation, and most muscles had prominent moment arms in at least 2 out of the 3 joint motions investigated. This study emphasizes the importance of detailed representation of a muscle's architecture in prediction of its torque capacity about the individual joints of the cervical spine. The dataset produced may be useful in developing and validating computational models of the human neck. Copyright © 2010 Elsevier Ltd. All rights reserved.
Xu, Yin; Xiao, Jinbiao
2016-01-20
A compact and integrated TM-rotated/TE-through polarization beam splitter for silicon-based slot waveguides is proposed and characterized. For the input TM mode, it is first transferred into the cross strip waveguide using a tapered directional coupler (DC), and then efficiently rotated to the corresponding TE mode using an L-shaped bending polarization rotator (PR). Finally, the TE mode for slot waveguide at the output end is obtained with the help of a strip-to-slot mode converter. By contrast, for the input TE mode, it almost passes through the slot waveguide directly and outputs at the bar end with nearly neglected coupling due to a large mode mismatch. Moreover, an additional S-bend connecting the tapered DC and bending PR is used to enhance the performance. Results show that a total device length of 19.6 μm is achieved, where the crosstalk (CT) and polarization conversion loss are, respectively -26.09 and 0.54 dB, for the TM mode, and the CT and insertion loss are, respectively, -22.21 and 0.41 dB, for the TE mode, both at 1.55 μm. The optical bandwidth is approximately 50 nm with a CT<-20 dB. In addition, fabrication tolerances and field evolution are also presented.
Approximations for column effect in airplane wing spars
NASA Technical Reports Server (NTRS)
Warner, Edward P; Short, Mac
1927-01-01
The significance attaching to "column effect" in airplane wing spars has been increasingly realized with the passage of time, but exact computations of the corrections to bending moment curves resulting from the existence of end loads are frequently omitted because of the additional labor involved in an analysis by rigorously correct methods. The present report represents an attempt to provide for approximate column effect corrections that can be graphically or otherwise expressed so as to be applied with a minimum of labor. Curves are plotted giving approximate values of the correction factors for single and two bay trusses of varying proportions and with various relationships between axial and lateral loads. It is further shown from an analysis of those curves that rough but useful approximations can be obtained from Perry's formula for corrected bending moment, with the assumed distance between points of inflection arbitrarily modified in accordance with rules given in the report. The discussion of general rules of variation of bending stress with axial load is accompanied by a study of the best distribution of the points of support along a spar for various conditions of loading.
Note on performance of tapered grip tensile loading devices
NASA Technical Reports Server (NTRS)
Jones, M. H.; Brown, W. F., Jr.
1975-01-01
Alignment results are presented in terms of percent bending for a quick release, tapered grip, tensile loading device that has been proposed for testing sharply notched specimens of aluminum and magnesium alloys by a Task Group of the ASTM Committee E-24 on Fracture Testing of Metals. The results show that the bending introduced by the fixtures is strongly dependent on their relative rotational positions in respect to the loading rods which adapt them, to the tensile machine. For one set of tapered grips the highest bending was about 15%. Recommendations are made for improvement in the design of the tapered grips which should reduce the bending stresses substantially.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skalozub, A.S.; Tsaune, A.Ya.
1994-12-01
A new approach for analyzing the highly excited vibration-rotation (VR) states of nonrigid molecules is suggested. It is based on the separation of the vibrational and rotational terms in the molecular VR Hamiltonian by introducing periodic auxiliary fields. These fields transfer different interactions within a molecule and are treated in terms of the mean-field approximation. As a result, the solution of the stationary Schroedinger equation with the VR Hamiltonian amounts to a quantization of the Berry phase in a problem of the molecular angular-momentum motion in a certain periodic VR field (rotational problem). The quantization procedure takes into account themore » motion of the collective vibrational variables in the appropriate VR potentials (vibrational problem). The quantization rules, the mean-field configurations of auxiliary interactions, and the solutions to the Schrodinger equations for the vibrational and rotational problems are self-consistently connected with one another. The potentialities of the theory are demonstrated by the bending-rotation interaction modeled by the Bunker-Landsberg potential function in the H{sub 2} molecule. The calculations are compared with both the results of the exact computations and those of other approximate methods. 32 refs., 4 tabs.« less
1989-12-01
ILLUSTRATIONS (CONTD) 44 Tubular strut wire - bending energy absorber ...... ........... 91 45 Inversion tube concepL with typical force-deformation...expected from a rod-bending sled decelerator and a wire - bending seat load limiter (Refer- ences 35 and 36). Therefore, correcting the calculated...attaching the seat bucket to the rollers, compressive as well as tensile loads can be sustained. Two variations of the wire - bending device have been
NASA Technical Reports Server (NTRS)
Tessarzik, J. M.
1975-01-01
Experimental tests were conducted to demonstrate the ability of the influence coefficient method to achieve precise balance of flexible rotors of virtually any design for operation through virtually any speed range. Various practical aspects of flexible-rotor balancing were investigated. Tests were made on a laboratory quality machine having a 122 cm (48 in.) long rotor weighing 50 kg (110 lb) and covering a speed range up to 18000 rpm. The balancing method was in every instance effective, practical, and economical and permitted safe rotor operation over the full speed range covering four rotor bending critical speeds. Improved correction weight removal methods for rotor balancing were investigated. Material removal from a rotating disk was demonstrated through application of a commercially available laser.
NASA Astrophysics Data System (ADS)
Sawaguchi, Tak Ahiro; Kausträter, Gregor; Yawny, Alejandro; Wagner, Martin; Eggeler, Gunther
2003-12-01
The structural fatigue of pseudoelastic Ni-Ti wires (50.9 at. pct Ni) was investigated using bending-rotation fatigue (BRF) tests, where a bent and otherwise unconstrained wire was forced to rotate at different rotational speeds. The number of cycles to failure ( N f ) was measured for different bending radii and wire thicknesses (1.0, 1.2, and 1.4 mm). The wires consisted of an alloy with a 50-nm grain size, no precipitates, and some TiC inclusions. In BRF tests, the surface of the wire is subjected to tension-compression cycles, and fatigue lives can be related to the maximum tension and compression strain amplitudes ( ɛ a ) in the wire surface. The resulting ɛ a - N f curves can be subdivided into three regimes. At ɛ a > 1 pct rupture occurs early (low N f ) and the fatigue-rupture characteristics were strongly dependent on ɛ a and the rotational speed (regime 1). For 0.75 pct < ɛ a < 1 pct, fatigue lives strongly increase and are characterized by a significant statistical scatter (regime 2). For ɛ a < 0.75 pct, no fatigue rupture occurs up to cycle numbers of 106 (regime 3). Using scanning electron microscopy (SEM), it was shown that surface cracks formed in regions with local stress raisers (such as inclusions and/or scratches). The growth of surface cracks during fatigue loading produced striations on the rupture surface; during final rupture, ductile voids form. The microstructural details of fatigue-damage accumulation during BRF testing are described and discussed.
Li, Jingfeng; Dumonski, Mark L; Samartzis, Dino; Hong, Joseph; He, Shisheng; Zhu, Xiaodong; Wang, Chuanfeng; Vaccaro, Alexander R; Albert, Todd J; Li, Ming
2011-01-01
The aim of the prospective, comparative radiographic analysis was to determine the role of the fulcrum-bending radiograph (FBR) for the assessment of the proximal thoracic (PT), main thoracic (MT), and the thoracolumbar/lumbar (TL/L) curves in patients undergoing posterior spinal pedicle screw fixation and fusion for adolescent idiopathic scoliosis (AIS). The FBR demonstrated statistically better correction than other preoperative methods for the assessment of frontal plane correction of the MT curves. The fulcrum-bending correction index (FBCI) has been considered a superior method than the correction rate for comparing curve correction undergoing posterior spinal fusion because it accounts for the curve flexibility. However, their applicability to assess the PT and TL/L curves in AIS patients remains speculative. The relation between FBR and correction obtained by pedicle screws fixation is still unknown. Thirty-eight consecutive AIS patients who underwent pedicle screw fixation and posterior fusion were included in this study. The assessment of preoperative radiographs included standing posterior-anterior (PA), FBR, supine side-bending, and postoperative standing PA and lateral plain radiographs. The flexibility of the curve, as well as the FBCI, was calculated for all patients. Postoperatively, radiographs were assessed at immediate (i.e. 1 week), 3-month, 6-month, 12-month, and 2-year follow-up. Cobb angles were obtained from the PT, MT, and TL/L curves. The study consisted of 9 PT, 37 MT, and 12 TL/L curves, with a mean age of 15.1 years. The mean FBR flexibility of the PT, MT, and the TL/L curves was 42.6, 61.1, and 66.2%, respectively. The mean operative correction rates in the PT, MT, and TL/L curves were 43.4, 69.3, and 73.9%, respectively, and the mean FBCI was 103.8, 117.0, and 114.8%, respectively. Fulcrum-bending flexibility was positively correlated with the operative correction rate in PT, MT, and TL/L curves. Although the correction rate in MT and TL/L curves was higher than PT curves, the FBCI in PT, MT, and TL/L curves was not significantly different (p < 0.05). The FBR can be used to assist in the assessment of PT, MT, and TL/L curve corrections in AIS patients. When curve flexibility is taken into account by FBR, the ability of pedicle screws to correct PT, MT, and TL/L curves is the same.
Yao, Guanfeng; Cheung, Jason P Y; Shigematsu, Hideki; Ohrt-Nissen, Søren; Cheung, Kenneth M C; Luk, Keith D K; Samartzis, Dino
2017-11-01
A prospective radiographic analysis of adolescent idiopathic scoliosis (AIS) patients managed with alternate-level pedicle screw fixation was performed. The objective of this study was to characterize segmental curve flexibility and to determine its predictive value in curve correction in AIS patients. Little is known regarding the distinct segmental curve characteristics and their ability to predict curve correction in patients with AIS. The segmental Cobb angle was measured on posteroanterior standing radiographs and on fulcrum bending radiographs. Radiographs were analyzed preoperatively and at 2 years postoperatively and the curve was divided into upper, mid, and lower segments based on predefined criteria. The segmental flexibility and the segmental fulcrum bending correction index (FBCI) were calculated. Eighty patients were included with mean age of 15 years. Preoperative mean segmental Cobb angles were 18, 31, and 17 degrees in the upper, mid, and lower segments, respectively. Segmental bending Cobb angles were 6, 13, and 4 degrees, respectively, corresponding to segmental flexibilities of 50%, 47%, and 83% in the upper, mid, and lower segments, respectively (P < 0.001). At 2-year follow up, the mean segmental FBCI were 155%, 131%, and 100% in the upper, mid, and lower segments, respectively (P < 0.001), which suggested that the lower segment of the curve was more flexible than the other segments and that higher correction was noted in the upper segments. A significant, positive correlation was noted between the segmental bending Cobb angle and the segmental FBCI (P < 0.05), whereby the strength of the correlation varied based on the curve segment. This is the first study to demonstrate the segmental variations in curve flexibility using the fulcrum bending radiograph in AIS patients. Curve flexibility is not uniform throughout the curve and different segments exhibit greater flexibility/correctibility than others. Segmental flexibility should be considered in assessing AIS patients and in the clinical decision-making strategy to optimize curve correction outcomes. 03.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boer, Johan de; Wolf, Anne Lisa; Szeto, Yenny Z.
2015-04-01
Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° weremore » corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.« less
Isotope effect in normal-to-local transition of acetylene bending modes
Ma, Jianyi; Xu, Dingguo; Guo, Hua; ...
2012-01-01
The normal-to-local transition for the bending modes of acetylene is considered a prelude to its isomerization to vinylidene. Here, such a transition in fully deuterated acetylene is investigated using a full-dimensional quantum model. It is found that the local benders emerge at much lower energies and bending quantum numbers than in the hydrogen isotopomer HCCH. This is accompanied by a transition to a second kind of bending mode called counter-rotator, again at lower energies and quantum numbers than in HCCH. These transitions are also investigated using bifurcation analysis of two empirical spectroscopic fitting Hamiltonians for pure bending modes, which helpsmore » to understand the origin of the transitions semiclassically as branchings or bifurcations out of the trans and normal bend modes when the latter become dynamically unstable. The results of the quantum model and the empirical bifurcation analysis are in very good agreement.« less
Metachronal Motion of Artificial Magnetic Cilia
NASA Astrophysics Data System (ADS)
Hanasoge, Srinivas; Hesketh, Peter; Alexeev, Alexander
2017-11-01
Most microorganisms use asymmetrically oscillating hair like cilia on their surface to achieve fluid transport. These cilia are often seen to beat in a metachronal fashion with a constant phase difference with the neighbors which generates a travelling wave. Although the origin of metachronal waves in such cilia is not well understood, mimicking such behavior in synthetic systems could prove useful in achieving similar advantages. In this work, we demonstrate metachronal waves in synthetic magnetic ciliary systems. The soft magnetic cilia are forced by a uniform rotating magnetic field. The cilia bend as the field rotates and tend to align along the direction of field to minimize the potential energy. Longer cilia bend to a larger degree, while the shorter cilia show less bending. This difference in the bending of cilia based on their length leads to a phase difference in their oscillation cycle. We exploit this phase differences to metachronally oscillate the synthetic cilia. We fabricate an array consisting of cilia with increasing lengths, in which the cilia beat with a constant phase difference with the neighboring cilia, producing a travelling wave. Such behavior could potentially be useful in enhanced fluid and particle transport as seen in natural systems. USDA.
Residual Field Correction of Pulsed Bending Magnet
NASA Astrophysics Data System (ADS)
Takano, Junpei; Igarashi, Susumu; Kamikubota, Norihiko; Meigo, Shin-ichiro; Sato, Kenichi; Shirakata, Masashi; Yamada, Shuei
The Japan Proton Accelerator Research Complex (J-PARC) has an accelerator chain, Linac, Rapid Cycling Synchrotron (RCS), and Main Ring (MR). The RCS accelerates the proton beam up to 3 GeV every 40 msec. After the beam is extracted from the RCS, it is delivered to a beam transport line, which is 3NBT for the Material and Life Science Experimental Facility (MLF). Some bunches of the proton beam are bended from the 3NBT to another beam transport line, which is 3-50BT for the MR, by using a pulsed bending magnet (PB) [1]. However, the beam orbit in the 3NBT is kicked by the residual magnetic field of the PB. In order to correct the residual magnetic field, additional coils had been wound on the PB poles. As a result of scanning the current pattern of the correction coils, the orbit distortion in the 3NBT has been reduced.
NASA Technical Reports Server (NTRS)
Subrahmanyam, K. B.; Kaza, K. R. V.; Brown, G. V.; Lawrence, C.
1987-01-01
The coupled bending-bending-torsional equations of dynamic motion of rotating, linearly pretwisted blades are derived including large precone, second degree geometric nonlinearities and Coriolis effects. The equations are solved by the Galerkin method and a linear perturbation technique. Accuracy of the present method is verified by conparisons of predicted frequencies and steady state deflections with those from MSC/NASTRAN and from experiments. Parametric results are generated to establish where inclusion of only the second degree geometric nonlinearities is adequate. The nonlinear terms causing torsional divergence in thin blades are identified. The effects of Coriolis terms and several other structurally nonlinear terms are studied, and their relative importance is examined.
Bian, Tianjian; Gao, Jie; Zhang, Chuang; ...
2017-12-10
In September 2012, Chinese scientists proposed a Circular Electron Positron Collider (CEPC) in China at 240 GeV center-of-mass energy for Higgs studies. The booster provides 120 GeV electron and positron beams to the CEPC collider for top-up injection at 0.1 Hz. The design of the full energy booster ring of the CEPC is a challenge. The ejected beam energy is 120 GeV and the injected beam energy is 6 GeV. Here in this paper we describe two alternative schemes, the wiggler bend scheme and the normal bend scheme. For the wiggler bend scheme, we propose to operate the booster ringmore » as a large wiggler at low energy and as a normal ring at high energy to avoid the problem of very low dipole magnet fields. Finally, for the normal bend scheme, we implement the orbit correction to correct the earth field.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bian, Tianjian; Gao, Jie; Zhang, Chuang
In September 2012, Chinese scientists proposed a Circular Electron Positron Collider (CEPC) in China at 240 GeV center-of-mass energy for Higgs studies. The booster provides 120 GeV electron and positron beams to the CEPC collider for top-up injection at 0.1 Hz. The design of the full energy booster ring of the CEPC is a challenge. The ejected beam energy is 120 GeV and the injected beam energy is 6 GeV. Here in this paper we describe two alternative schemes, the wiggler bend scheme and the normal bend scheme. For the wiggler bend scheme, we propose to operate the booster ringmore » as a large wiggler at low energy and as a normal ring at high energy to avoid the problem of very low dipole magnet fields. Finally, for the normal bend scheme, we implement the orbit correction to correct the earth field.« less
A three-dimensional nonlinear Timoshenko beam based on the core-congruential formulation
NASA Technical Reports Server (NTRS)
Crivelli, Luis A.; Felippa, Carlos A.
1992-01-01
A three-dimensional, geometrically nonlinear two-node Timoshenkoo beam element based on the total Larangrian description is derived. The element behavior is assumed to be linear elastic, but no restrictions are placed on magnitude of finite rotations. The resulting element has twelve degrees of freedom: six translational components and six rotational-vector components. The formulation uses the Green-Lagrange strains and second Piola-Kirchhoff stresses as energy-conjugate variables and accounts for the bending-stretching and bending-torsional coupling effects without special provisions. The core-congruential formulation (CCF) is used to derived the discrete equations in a staged manner. Core equations involving the internal force vector and tangent stiffness matrix are developed at the particle level. A sequence of matrix transformations carries these equations to beam cross-sections and finally to the element nodal degrees of freedom. The choice of finite rotation measure is made in the next-to-last transformation stage, and the choice of over-the-element interpolation in the last one. The tangent stiffness matrix is found to retain symmetry if the rotational vector is chosen to measure finite rotations. An extensive set of numerical examples is presented to test and validate the present element.
NASA Astrophysics Data System (ADS)
Panchal, Arun; Bano, Anees; Ghate, Mahesh; Raj, Piyush; Pradhan, Subrata
2017-04-01
An indigenously developed bending strain setup to examine the effect of pure bending on critical current of superconducting tapes and strands has been presented in this paper. This set up is capable of applying various bending radius in situ at cryogenic temperature with rack and pinion gear mechanism. The bending strain applied on samples can be controlled externally by rotational input which is transferred in the form of bending radius during experiments. The working principle, design and optimization of this set up have been discussed. The performance and validation of this setup has been done on various HTS tapes and copper strands at 77 K in actual experimental facility. Effect of bending radius (15.5 mm - 48 mm) i.e. strains and ramp rate (2 A/s - 8 A/s) is observed on current capability of various HTS Tapes. It is observed that in uniform bending condition, degradation in current carrying capacity BSCCO and Di-BSCCO (˜ 30 %) is more as compare to YBCO (˜ 2.75 %) at 77 K. The effect of pure mechanical strain has been experimentally observed and presented.
Breen, Alexander C; Dupac, Mihai; Osborne, Neil
2015-01-01
Lumbar segmental instability is often considered to be a cause of chronic low back pain. However, defining its measurement has been largely limited to laboratory studies. These have characterised segmental stability as the intrinsic resistance of spine specimens to initial bending moments by quantifying the dynamic neutral zone. However these measurements have been impossible to obtain in vivo without invasive procedures, preventing the assessment of intervertebral stability in patients. Quantitative fluoroscopy (QF), measures the initial velocity of the attainment of intervertebral rotational motion in patients, which may to some extent be representative of the dynamic neutral zone. This study sought to explore the possible relationship between the dynamic neutral zone and intervertebral rotational attainment rate as measured with (QF) in an in vitro preparation. The purpose was to find out if further work into this concept is worth pursuing. This study used passive recumbent QF in a multi-segmental porcine model. This assessed the intrinsic intervertebral responses to a minimal coronal plane bending moment as measured with a digital force guage. Bending moments about each intervertebral joint were calculated and correlated with the rate at which global motion was attained at each intervertebral segment in the first 10° of global motion where the intervertebral joint was rotating. Unlike previous studies of single segment specimens, a neutral zone was found to exist during lateral bending. The initial attainment rates for left and right lateral flexion were comparable to previously published in vivo values for healthy controls. Substantial and highly significant levels of correlation between initial attainment rate and neutral zone were found for left (Rho = 0.75, P = 0.0002) and combined left-right bending (Rho = 0.72, P = 0.0001) and moderate ones for right alone (Rho = 0.55, P = 0.0012). This study found good correlation between the initial intervertebral attainment rate and the dynamic neutral zone, thereby opening the possibility to detect segmental instability from clinical studies. However the results must be treated with caution. Further studies with multiple specimens and adding sagittal plane motion are warranted.
Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey
2017-12-01
Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
3D MHD Simulations of Waves Excited in an Accretion Disk by a Rotating Magnetized Star
NASA Astrophysics Data System (ADS)
Lovelace, R. V. E.; Romanova, M. M.
2014-01-01
We present results of global 3D MHD simulations of warp and density waves in accretion disks excited by a rotating star with a misaligned dipole magnetic field. A wide range of cases are considered. We find for example that if the star's magnetosphere corotates approximately with the inner disk, then a strong one-arm bending wave or warp forms. The warp corotates with the star and has a maximum amplitude (|zω|/r ~ 0.3) between the corotation radius and the radius of the vertical resonance. If the magnetosphere rotates more slowly than the inner disk, then a bending wave is excited at the disk-magnetosphere boundary, but it does not form a large-scale warp. In this case the angular rotation of the disk [Ω(r,z = 0)] has a maximum as a function of r so that there is an inner region where dΩ/dr > 0. In this region we observe radially trapped density waves in approximate agreement with the theoretical prediction of a Rossby wave instability in this region.
NASA Technical Reports Server (NTRS)
Gray, Carl E., Jr.
1988-01-01
Using the Newtonian method, the equations of motion are developed for the coupled bending-torsion steady-state response of beams rotating at constant angular velocity in a fixed plane. The resulting equations are valid to first order strain-displacement relationships for a long beam with all other nonlinear terms retained. In addition, the equations are valid for beams with the mass centroidal axis offset (eccentric) from the elastic axis, nonuniform mass and section properties, and variable twist. The solution of these coupled, nonlinear, nonhomogeneous, differential equations is obtained by modifying a Hunter linear second-order transfer-matrix solution procedure to solve the nonlinear differential equations and programming the solution for a desk-top personal computer. The modified transfer-matrix method was verified by comparing the solution for a rotating beam with a geometric, nonlinear, finite-element computer code solution; and for a simple rotating beam problem, the modified method demonstrated a significant advantage over the finite-element solution in accuracy, ease of solution, and actual computer processing time required to effect a solution.
T-bone plastique for treatment of brachy-turricephaly.
Donauer, E; Bernardy, M; Neuenfeldt, D
1993-01-01
The "T-Bone Plastique", which is presented in this paper, allows a surgical correction even of extreme cases of brachy-turricephaly together with malformations of the occipital region in one operative session. Brachy-turricephaly is characterized by abnormal vertical height of the skull and a shortening of its anterior-posterior length, frequently combined with malformations of the occipital region. Resection of the prematurely closed coronal suture, bi-parietal trepanations with 90 degrees rotation and side-exchange of the parietal bone flaps, double transverse trepanation of the occipital bone and outward bending and shifting of the bone fragments enable a bony remodeling and normalization of the deformed skull. Using this operative technique in three children we achieved a significant improvement of the skull form with an aesthetically pleasing result, without any neurologic sequelae and with normal development of the children during follow-up.
NASA Astrophysics Data System (ADS)
Azpiroz, M.; Cartigny, M.; Sumner, E. J.; Talling, P.; Parsons, D. R.; Clare, M. A.; Cooper, C.
2017-12-01
Turbidity currents transport sediment through submarine channel systems for hundreds of kilometres to form vast deposits of sediment in the deep sea called submarine fans. The largest submarine fans are fed by meandering channels suggesting that bends may enhance sediment transport distances. The interaction between meander bends and turbidity currents has been a topic of intense debate. Due to the absence of observations of deep-sea turbidity currents flowing through meander bends, our understanding has been based on experimental and numerical models. Measurements of geophysical flows demonstrate a common helical flow structure around meanders. Previous work has demonstrated that helical circulation in rivers is dominated by a single helix that rotates towards the inner bend at near-bed depths. In contrast, initial numerical and experimental models for turbidity currents found both river-like and river-reversed circulations. Saline flows in well-mixed estuaries show a river-like basal helical circulation, while stratified estuaries and saline flows are river-reversed. The existence of lateral stratification in stratified flows is thought to be the key factor in the change of direction of rotation. Stratification causes lateral pressure gradients that can govern the rotation of the flow helix. Turbidity currents are stratified due to their upwards-decreasing sediment load. It has therefore been proposed that stratified turbidity currents behave like stratified saline flow, but this hypothesis remains so far untested. Here we present the first observations of the helical flow in turbidity currents, which occurred within the deep-sea Congo Canyon. The measurements show a consistent river-reversed pattern downstream of the bend apex. Those results lead us to develop a new generalised model for a wide range of flows around meanders. Our conclusions have implications for understanding the flow erosional and depositional patterns, the evolution of channel systems and the architecture of the depositional record.
NASA Technical Reports Server (NTRS)
Jedlicka, J. R.; Guist, L. R.; Beam, R. M. (Inventor)
1974-01-01
A device is described which uses a single phase metallic working substance to convert thermal energy directly into mechanical energy. The device consists of a cylindrical metal tube which is free to rotate about its axis while being subjected to continuous bending moment stresses along the longitudinal axis of rotation. The stressing causes portions of the tube to be under compression while other parts are under tension which in turn causes the tube to rotate and provide mechanical energy.
Test Equal Bending by Gravity for Space and Time
NASA Astrophysics Data System (ADS)
Sweetser, Douglas
2009-05-01
For the simplest problem of gravity - a static, non-rotating, spherically symmetric source - the solution for spacetime bending around the Sun should be evenly split between time and space. That is true to first order in M/R, and confirmed by experiment. At second order, general relativity predicts different amounts of contribution from time and space without a physical justification. I show an exponential metric is consistent with light bending to first order, measurably different at second order. All terms to all orders show equal contributions from space and time. Beautiful minimalism is Nature's way.
NASA Astrophysics Data System (ADS)
SONG, O.; JEONG, N.-H.; LIBRESCU, L.
2000-10-01
A number of issues related to the modelling, vibration and stability of anisotropic pretwisted beams rotating at constant angular speed about the longitudinal body-axis fixed in the inertial space are investigated. The analysis is carried out in the framework of a refined theory of thin-walled anisotropic composite beams featuring bending-bending elastic coupling, and encompassing a number of non-classical features such as transverse-shear, anisotropy and pretwist. Special attention is paid to the effect of the spinning speed, pretwist angle, axial compressive load and symmetry/non-symmetry of the beam cross-section on natural frequencies and instability of the structural system. Numerical illustrations highlighting their implication on vibration and stability are displayed and pertinent conclusions are outlined.
Statistical model of a flexible inextensible polymer chain: The effect of kinetic energy.
Pergamenshchik, V M; Vozniak, A B
2017-01-01
Because of the holonomic constraints, the kinetic energy contribution in the partition function of an inextensible polymer chain is difficult to find, and it has been systematically ignored. We present the first thermodynamic calculation incorporating the kinetic energy of an inextensible polymer chain with the bending energy. To explore the effect of the translation-rotation degrees of freedom, we propose and solve a statistical model of a fully flexible chain of N+1 linked beads which, in the limit of smooth bending, is equivalent to the well-known wormlike chain model. The partition function with the kinetic and bending energies and correlations between orientations of any pair of links and velocities of any pair of beads are found. This solution is precise in the limits of small and large rigidity-to-temperature ratio b/T. The last exact solution is essential as even very "harmless" approximation results in loss of the important effects when the chain is very rigid. For very high b/T, the orientations of different links become fully correlated. Nevertheless, the chain does not go over into a hard rod even in the limit b/T→∞: While the velocity correlation length diverges, the correlations themselves remain weak and tend to the value ∝T/(N+1). The N dependence of the partition function is essentially determined by the kinetic energy contribution. We demonstrate that to obtain the correct energy and entropy in a constrained system, the T derivative of the partition function has to be applied before integration over the constraint-setting variable.
Statistical model of a flexible inextensible polymer chain: The effect of kinetic energy
NASA Astrophysics Data System (ADS)
Pergamenshchik, V. M.; Vozniak, A. B.
2017-01-01
Because of the holonomic constraints, the kinetic energy contribution in the partition function of an inextensible polymer chain is difficult to find, and it has been systematically ignored. We present the first thermodynamic calculation incorporating the kinetic energy of an inextensible polymer chain with the bending energy. To explore the effect of the translation-rotation degrees of freedom, we propose and solve a statistical model of a fully flexible chain of N +1 linked beads which, in the limit of smooth bending, is equivalent to the well-known wormlike chain model. The partition function with the kinetic and bending energies and correlations between orientations of any pair of links and velocities of any pair of beads are found. This solution is precise in the limits of small and large rigidity-to-temperature ratio b /T . The last exact solution is essential as even very "harmless" approximation results in loss of the important effects when the chain is very rigid. For very high b /T , the orientations of different links become fully correlated. Nevertheless, the chain does not go over into a hard rod even in the limit b /T →∞ : While the velocity correlation length diverges, the correlations themselves remain weak and tend to the value ∝T /(N +1 ). The N dependence of the partition function is essentially determined by the kinetic energy contribution. We demonstrate that to obtain the correct energy and entropy in a constrained system, the T derivative of the partition function has to be applied before integration over the constraint-setting variable.
NASA Astrophysics Data System (ADS)
Park, G. Barratt; Baraban, Joshua H.; Field, Robert W.
2014-10-01
A full-dimensional Franck-Condon calculation has been applied to the tilde{A} 1Au—tilde{X} ^1Σ _g^+ transition in acetylene in the harmonic normal mode basis. Details of the calculation are discussed in Part I of this series. To our knowledge, this is the first full-dimensional Franck-Condon calculation on a tetra-atomic molecule undergoing a linear-to-bent geometry change. In the current work, the vibrational intensity factors for levels involving excitation in ungerade vibrational modes are evaluated. Because the Franck-Condon integral accumulates away from the linear geometry, we have been able to treat the out-of-plane component of trans bend (ν _4^' ' }) in the linear tilde{X} state in the rotational part of the problem, restoring the χ Euler angle and the a-axis Eckart conditions. A consequence of the Eckart conditions is that the out-of-plane component of ν _4^' ' } does not participate in the vibrational overlap integral. This affects the structure of the coordinate transformation and the symmetry of the vibrational wavefunctions used in the overlap integral, and results in propensity rules involving the bending modes of the tilde{X} state that were not previously understood. We explain the origin of some of the unexpected propensities observed in IR-UV laser-induced fluorescence spectra, and we calculate emission intensities from bending levels of the tilde{A} state into bending levels of the tilde{X} state, using normal bending mode and local bending mode basis sets. Our calculations also reveal Franck-Condon propensities for the Cartesian components of the cis bend (ν _5^' ' }), and we predict that the best tilde{A}-state vibrational levels for populating tilde{X}-state levels with large amplitude bending motion localized in a single C-H bond (the acetylene↔vinylidene isomerization coordinate) involve a high degree of excitation in ν _6^' } (cis-bend). Mode ν _4^' } (torsion) populates levels with large amplitude counter-rotational motion of the two hydrogen atoms.
Progress in Finite Element Modeling of the Lower Extremities
2015-06-01
bending and subsequent injury , e.g., the distal tibia motion results in bending of the tibia rather than the tibia rotating about the knee joint...layers, rich anisotropy, and wide variability. Developing a model for predictive injury capability, therefore, needs to be versatile and flexible to... injury capability presents many challenges, the first of which is identifying the types of conditions where injury prediction is needed. Our focus
Optical anisotropy in micromechanically rolled carbon nanotube forest
NASA Astrophysics Data System (ADS)
Razib, Mohd Asyraf bin Mohd; Rana, Masud; Saleh, Tanveer; Fan, Harrison; Koch, Andrew; Nojeh, Alireza; Takahata, Kenichi; Muthalif, Asan Gani Bin Abdul
2017-09-01
The bulk appearance of arrays of vertically aligned carbon nanotubes (VACNT arrays or CNT forests) is dark as they absorb most of the incident light. In this paper, two postprocessing techniques have been described where the CNT forest can be patterned by selective bending of the tips of the nanotubes using a rigid cylindrical tool. A tungsten tool was used to bend the vertical structure of CNTs with predefined parameters in two different ways as stated above: bending using the bottom surface of the tool (micromechanical bending (M2B)) and rolling using the side of the tool (micromechanical rolling (M2R)). The processed zone was investigated using a Field Emission Scanning Electron Microscope (FESEM) and optical setup to reveal the surface morphology and optical characteristics of the patterned CNTs on the substrate. Interestingly, the polarized optical reflection from the micromechanical rolled (M2R) sample was found to be significantly influenced by the rotation of the sample. It was observed that, if the polarization of the light is parallel to the alignment of the CNTs, the reflectance is at least 2 x higher than for the perpendicular direction. Furthermore, the reflectance varied almost linearly with good repeatability ( 10%) as the processed CNT forest sample was rotated from 0° to 90°. [Figure not available: see fulltext.
Fully Suspended, Five-Axis, Three-Magnetic-Bearing Dynamic Spin Rig With Forced Excitation
NASA Technical Reports Server (NTRS)
Morrison, Carlos R.; Provenza, Andrew; Kurkov, Anatole; Montague, Gerald; Duffy, Kirsten; Mehmed, Oral; Johnson, Dexter; Jansen, Ralph
2004-01-01
The Five-Axis, Three-Magnetic-Bearing Dynamic Spin Rig, a significant advancement in the Dynamic Spin Rig (DSR), is used to perform vibration tests of turbomachinery blades and components under rotating and nonrotating conditions in a vacuum. The rig has as its critical components three magnetic bearings: two heteropolar radial active magnetic bearings and a magnetic thrust bearing. The bearing configuration allows full vertical rotor magnetic suspension along with a feed-forward control feature, which will enable the excitation of various natural blade modes in bladed disk test articles. The theoretical, mechanical, electrical, and electronic aspects of the rig are discussed. Also presented are the forced-excitation results of a fully levitated, rotating and nonrotating, unbladed rotor and a fully levitated, rotating and nonrotating, bladed rotor in which a pair of blades was arranged 180 degrees apart from each other. These tests include the bounce mode excitation of the rotor in which the rotor was excited at the blade natural frequency of 144 Hz. The rotor natural mode frequency of 355 Hz was discerned from the plot of acceleration versus frequency. For nonrotating blades, a blade-tip excitation amplitude of approximately 100 g/A was achieved at the first-bending critical (approximately 144 Hz) and at the first-torsional and second-bending blade modes. A blade-tip displacement of 70 mils was achieved at the first-bending critical by exciting the blades at a forced-excitation phase angle of 908 relative to the vertical plane containing the blades while simultaneously rotating the shaft at 3000 rpm.
Plucking a hydrogen bond: A near infrared study of all four intermolecular modes in (DF)2
NASA Astrophysics Data System (ADS)
Davis, Scott; Anderson, David T.; Nesbitt, David J.
1996-10-01
The near ir combination band spectra of supersonically cooled (DF)2 in the 2900 to 3300 cm-1 region have been recorded with a high resolution slit jet spectrometer. Twelve vibration-rotation-tunneling (VRT) bands are observed, representing each of the four intermolecular modes (van der Waals stretch ν4, geared bend ν5, out-of-plane torsion ν6, and antigeared bend ν3) built as combination bands on either the ν1 (free) or ν2 (bound) DF stretches. Analysis of the rotationally resolved spectra provide spectroscopic constants, intermolecular frequencies, tunneling splittings, and predissociation rates as a function of both intra- and intermolecular excitation. The intermolecular frequencies demonstrate a small but systematic dependence on intramolecular mode, which is exploited to yield frequency predictions relevant to far-ir studies, as well as facilitate direct comparison with full 6-D quantum calculations on trial potential surfaces. The tunneling splittings demonstrate a much stronger dependence upon intermolecular mode, increasing by as much as an order of magnitude for geared bend excitation. Conversely, high resolution line shape analysis reveals that vibrational predissociation broadening is only modestly affected by intermolecular excitation, and instead exhibits mode specific behavior controlled predominantly by intramolecular excitation. Detailed H/D isotopic vibrational shifts are obtained by comparison with previous combination band studies of all four intermolecular modes in (HF)2. In contrast to the strong state mixing previously observed for (HF)2, the van der Waals stretch and geared bend degrees of freedom are largely decoupled in (DF)2, due to isotopically ``detuning'' of resonances between bend-stretch intermolecular vibrations. Four-dimensional quantum calculations of the (HF)2 and (DF)2 eigenfunctions indicate that the isotopic dependence of this bend-stretch resonance behavior is incorrectly predicted by current hydrogen bond potential surfaces.
Finite element analysis of moment-rotation relationships for human cervical spine.
Zhang, Qing Hang; Teo, Ee Chon; Ng, Hong Wan; Lee, Vee Sin
2006-01-01
A comprehensive, geometrically accurate, nonlinear C0-C7 FE model of head and cervical spine based on the actual geometry of a human cadaver specimen was developed. The motions of each cervical vertebral level under pure moment loading of 1.0 Nm applied incrementally on the skull to simulate the movements of the head and cervical spine under flexion, tension, axial rotation and lateral bending with the inferior surface of the C7 vertebral body fully constrained were analysed. The predicted range of motion (ROM) for each motion segment were computed and compared with published experimental data. The model predicted the nonlinear moment-rotation relationship of human cervical spine. Under the same loading magnitude, the model predicted the largest rotation in extension, followed by flexion and axial rotation, and least ROM in lateral bending. The upper cervical spines are more flexible than the lower cervical levels. The motions of the two uppermost motion segments account for half (or even higher) of the whole cervical spine motion under rotational loadings. The differences in the ROMs among the lower cervical spines (C3-C7) were relatively small. The FE predicted segmental motions effectively reflect the behavior of human cervical spine and were in agreement with the experimental data. The C0-C7 FE model offers potentials for biomedical and injury studies.
NASA Astrophysics Data System (ADS)
Chen, Lin; Sun, Limin; Nagarajaiah, Satish
2016-09-01
Lateral dampers have been extensively studied and implemented for supplementing modal damping in cable vibration mitigation. When considering the cable flexural stiffness that is actually present, albeit small, there is another degree of freedom of the cable at the lateral damper, namely the rotation, that can be constrained by a rotational damper to achieve larger additional damping. This is of particular significance for long cables where the near-anchorage lateral damper alone is usually insufficient. The problem of a cable with bending stiffness, attached with both lateral and rotational dampers at an intermediate point, is therefore considered in this study. The characteristic equation of the resulting system is formulated by assembling the dynamic stiffness from the two segments divided by the damper, which is subsequently solved using argument principle method. Dynamics of the controlled system is thus discussed in general through parametric analysis. For the case where the damper location is close to the anchorage, asymptotic solutions for complex frequency and damping ratio are provided; explicit formulas for determining the optimal damper coefficients are also derived. It is found that when the lateral and rotational damper coefficients are properly balanced, the proposed strategy can achieve up to 30 percent damping enhancement compared to the case with only the lateral damper, in practical cable bending stiffness range.
Rotational spectra in the ν2 vibrationally excited states of MgNC
NASA Astrophysics Data System (ADS)
Kagi, E.; Kawaguchi, K.; Takano, S.; Hirano, T.
1996-01-01
The pure rotational spectra of MgNC in the ν2 (bending) vibrationally excited states were observed in the 310-380 GHz region to study the linearity of the molecule. The observed 90 spectral lines were assigned to the transitions in the v2=1-5 states and analyzed to determine a set of molecular constants in each state. The bending vibrational frequency was estimated to be 86 cm-1 from the l-type doubling constant of the v2=1 state. The interval of the Φ and Π states in v2=3 was determined to be 29.2280(24) cm-1, giving the anharmonicity constant xll=3.8611(9) cm-1 with one standard deviation in parentheses, which indicates that the molecule has a linear form. However, somewhat peculiar properties were recognized in dependence of the observed l-type resonance and vibration-rotation constants on the v2 vibrational quantum number, suggesting an effect of anharmonicity.
Aircraft Crash Survival Design Guide. Volume 4. Aircraft Seats, Restraints. Litters, and Padding
1980-06-01
11i 34 Tubular strut wire - bending energy absorber with force-deflection curves ..... . . . . . . . . . . 113 35 Inversion tube concept with...decelera- tor and a wire - bending seat load limiter (References 31 and 32). Therefore, correcting the calculated distance yields 16.25/0.8 - 20.31 in. It...Naval Air Development Center, Warminster, Pennsylvania, October 1969. )- 109 I-. - - ’. Two variations of the wire - bending device have been developed and
2014-01-01
Background Cervical Spinal Manipulation (CSM) is considered a high-level skill of the central nervous system because it requires bimanual coordinated rhythmical movements therefore necessitating training to achieve proficiency. The objective of the present study was to investigate the effect of real-time feedback on the performance of CSM. Methods Six postgraduate physiotherapy students attending a training workshop on Cervical Spine Manipulation Technique (CSMT) using inertial sensor derived real-time feedback participated in this study. The key variables were pre-manipulative position, angular displacement of the thrust and angular velocity of the thrust. Differences between variables before and after training were investigated using t-tests. Results There were no significant differences after training for the pre-manipulative position (rotation p = 0.549; side bending p = 0.312) or for thrust displacement (rotation p = 0.247; side bending p = 0.314). Thrust angular velocity demonstrated a significant difference following training for rotation (pre-training mean (sd) 48.9°/s (35.1); post-training mean (sd) 96.9°/s (53.9); p = 0.027) but not for side bending (p = 0.521). Conclusion Real-time feedback using an inertial sensor may be valuable in the development of specific manipulative skill. Future studies investigating manipulation could consider a randomized controlled trial using inertial sensor real time feedback compared to traditional training. PMID:24942483
Steiner, Malte; Claes, Lutz; Ignatius, Anita; Niemeyer, Frank; Simon, Ulrich; Wehner, Tim
2013-09-06
Numerical models of secondary fracture healing are based on mechanoregulatory algorithms that use distortional strain alone or in combination with either dilatational strain or fluid velocity as determining stimuli for tissue differentiation and development. Comparison of these algorithms has previously suggested that healing processes under torsional rotational loading can only be properly simulated by considering fluid velocity and deviatoric strain as the regulatory stimuli. We hypothesize that sufficient calibration on uncertain input parameters will enhance our existing model, which uses distortional and dilatational strains as determining stimuli, to properly simulate fracture healing under various loading conditions including also torsional rotation. Therefore, we minimized the difference between numerically simulated and experimentally measured courses of interfragmentary movements of two axial compressive cases and two shear load cases (torsional and translational) by varying several input parameter values within their predefined bounds. The calibrated model was then qualitatively evaluated on the ability to predict physiological changes of spatial and temporal tissue distributions, based on respective in vivo data. Finally, we corroborated the model on five additional axial compressive and one asymmetrical bending load case. We conclude that our model, using distortional and dilatational strains as determining stimuli, is able to simulate fracture-healing processes not only under axial compression and torsional rotation but also under translational shear and asymmetrical bending loading conditions.
Dynamic characteristics of rotor blades with pendulum absorbers
NASA Technical Reports Server (NTRS)
Murthy, V. R.; Goglia, G. L.
1977-01-01
The point transmission matrix for a vertical plane pendulum on a rotating blade undergoing combined flapwise bending, and chordwise bending and torsion is derived. The equilibrium equation of the pendulum is linearized for small oscillations about the steady state. A FORTRAN program was written for the case of a vertical plane pendulum attached to a uniform blade with flapwise bending degree of freedom for cantilever boundary conditions. The frequency has a singular value right at the uncoupled pendulum natural frequency and thus introduces two frequencies corresponding to the nearest natural frequency of the blade without pendulum. In both of these modes it was observed that the pendulum deflection is large. One frequency can be thought of as a coupled pendulum frequency and the other as a coupled bending and pendulum frequency.
Assessment of Curve Flexibility on Scoliotic Surgical Candidates Using Ultrasound Imaging Method.
Zheng, Rui; Hill, Doug; Hedden, Douglas; Moreau, Marc; Le, Lawrence H; Raso, Jim; Lou, Edmond
2017-05-01
The ultrasound imaging method was implemented to assess the spinal curve flexibility of scoliotic surgical candidates, or how much correction it can achieve while patients are bending or lying down. Fifteen participants were recruited. Pre-operative radiographs and ultrasound images in both standing and bending positions were acquired. The post-operative standing radiographs were obtained 1 wk after surgery. Two raters (RZ, EL) measured the ultrasound images twice, 1 wk apart. A curve correction index (C I ) was developed to estimate the curve flexibility. The C I from the pre-operative bending radiograph, ultrasound and post-operative radiograph were 0.51 ± 0.18; R1: 0.74 ± 0.08 vs R2: 0.72 ± 0.09 and 0.60 ± 0.10, respectively. The correlation of C I between ultrasound and post-operative radiography was slightly higher than the pre-operative bending and post-operative radiography. This pilot study demonstrated the bending ultrasound method is a promising supplemental tool to assess curve flexibility before surgical intervention for scoliotic surgical candidates. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Sudo, Hideki; Abe, Yuichiro; Abumi, Kuniyoshi; Iwasaki, Norimasa; Ito, Manabu
2016-02-01
There is limited consensus on the optimal surgical strategy for double thoracic adolescent idiopathic scoliosis (AIS). Recent studies have reported that pedicle screw constructs to maximize scoliosis correction cause further thoracic spine lordosis. The objective of this study was to apply a new surgical technique for double thoracic AIS with rigid proximal thoracic (PT) curves and assess its clinical outcomes. Twenty one consecutive patients with Lenke 2 AIS and a rigid PT curve (Cobb angle ≥30º on side-bending radiographs, flexibility ≤30 %) treated with the simultaneous double-rod rotation technique (SDRRT) were included. In this technique, a temporary rod is placed at the concave side of the PT curve. Then, distraction force is applied to correct the PT curve, which reforms a sigmoid double thoracic curve into an approximate single thoracic curve. As a result, the PT curve is typically converted from an apex left to an apex right curve before applying the correction rod for PT and main thoracic curve. All patients were followed for at least 2 years (average 2.7 years). The average main thoracic and PT Cobb angle correction rate at the final follow-up was 74.7 and 58.0 %, respectively. The average preoperative T5-T12 thoracic kyphosis was 9.3°, which improved significantly to 19.0° (p < 0.0001) at the final follow-up. Although 71 % patients had preoperative level shoulders or a positive radiographic shoulder height, all patients had mildly imbalanced or balanced shoulders at the final follow-up. The average preoperative main thoracic apical vertebral rotation angle of 20.7° improved significantly after surgery to 16.4° (p = 0.0046), while the average preoperative total SRS questionnaire score of 3.7 improved significantly to 4.4 (p = 0.0012) at the final follow-up. Radiographic findings and patient outcomes were satisfactory. Thoracic kyphosis can be maintained or improved, while coronal and axial deformities can be corrected using SDRRT for Lenke 2 AIS with a rigid PT curve.
The Rotational Spectrum of Iodine Dioxide, OIO
NASA Technical Reports Server (NTRS)
Miller, Charles E.; Cohen, Edward A.
2000-01-01
The rotational spectra of OIO in its ground vibrational and first excited bending states have been observed for the first time. OIO was formed initially from the products of a microwave discharge in O2 passing over molecular iodine and later with greater yield in a DC discharge through a mixture of O2 and I2 vapor. OIO is an asymmetric prolate rotor (kappa = -0.690) with a (sup 2)B(sub 1) electronic ground state. Over 550 ground state transitions and over 160 transitions of the excited bending state have been included in the fits. The resulting parameters are well determined and will be compared to those recently published for OBrO and OClO. These will be interpreted in terms of the molecular geometry, harmonic force field, and electronic structure.
Numerical and experimental investigation of the bending response of thin-walled composite cylinders
NASA Technical Reports Server (NTRS)
Fuchs, J. P.; Hyer, M. W.; Starnes, J. H., Jr.
1993-01-01
A numerical and experimental investigation of the bending behavior of six eight-ply graphite-epoxy circular cylinders is presented. Bending is induced by applying a known end-rotation to each end of the cylinders, analogous to a beam in bending. The cylinders have a nominal radius of 6 inches, a length-to-radius ratio of 2 and 5, and a radius-to-thickness ratio of approximately 160. A (+/- 45/0/90)S quasi-isotropic layup and two orthotropic layups, (+/- 45/0 sub 2)S and (+/- 45/90 sub 2)S, are studied. A geometrically nonlinear special-purpose analysis, based on Donnell's nonlinear shell equations, is developed to study the prebuckling responses and gain insight into the effects of non-ideal boundary conditions and initial geometric imperfections. A geometrically nonlinear finite element analysis is utilized to compare with the prebuckling solutions of the special-purpose analysis and to study the buckling and post buckling responses of both geometrically perfect and imperfect cylinders. The imperfect cylinder geometries are represented by an analytical approximation of the measured shape imperfections. Extensive experimental data are obtained from quasi-static tests of the cylinders using a test fixture specifically designed for the present investigation. A description of the test fixture is included. The experimental data are compared to predictions for both perfect and imperfect cylinder geometries. Prebuckling results are presented in the form of displacement and strain profiles. Buckling end-rotations, moments, and strains are reported, and predicted mode shapes are presented. Observed and predicted moment vs. end-rotation relations, deflection patterns, and strain profiles are illustrated for the post buckling responses. It is found that a geometrically nonlinear boundary layer behavior characterizes the prebuckling responses. The boundary layer behavior is sensitive to laminate orthotropy, cylinder geometry, initial geometric imperfections, applied end-rotation, and non-ideal boundary conditions. Buckling end-rotations, strains, and moments are influenced by laminate orthotropy and initial geometric imperfections. Measured buckling results correlate well with predictions for the geometrically imperfect specimens. The postbuckling analyses predict equilibrium paths with a number of scallop-shaped branches that correspond to unique deflection patterns. The observed postbuckling deflection patterns and measured strain profiles show striking similarities to the predictions in some cases. Ultimate failure of the cylinders is attributed to an interlaminar shear failure mode along the nodal lines of the postbuckling deflection patterns.
Dynamic in vivo 3D atlantoaxial spine kinematics during upright rotation.
Anderst, William; Rynearson, Bryan; West, Tyler; Donaldson, William; Lee, Joon
2017-07-26
Diagnosing dysfunctional atlantoaxial motion is challenging given limitations of current diagnostic imaging techniques. Three-dimensional imaging during upright functional motion may be useful in identifying dynamic instability not apparent on static imaging. Abnormal atlantoaxial motion has been linked to numerous pathologies including whiplash, cervicogenic headaches, C2 fractures, and rheumatoid arthritis. However, normal C1/C2 rotational kinematics under dynamic physiologic loading have not been previously reported owing to imaging difficulties. The objective of this study was to determine dynamic three-dimensional in vivo C1/C2 kinematics during upright axial rotation. Twenty young healthy adults performed full head rotation while seated within a biplane X-ray system while radiographs were collected at 30 images per second. Six degree-of-freedom kinematics were determined for C1 and C2 via a validated volumetric model-based tracking process. The maximum global head rotation (to one side) was 73.6±8.3°, whereas maximum C1 rotation relative to C2 was 36.8±6.7°. The relationship between C1/C2 rotation and head rotation was linear through midrange motion (±20° head rotation from neutral) in a nearly 1:1 ratio. Coupled rotation between C1 and C2 included 4.5±3.1° of flexion and 6.4±8.2° of extension, and 9.8±3.8° of contralateral bending. Translational motion of C1 relative to C2 was 7.8±1.5mm ipsilaterally, 2.2±1.2mm inferiorly, and 3.3±1.0mm posteriorly. We believe this is the first study describing 3D dynamic atlantoaxial kinematics under true physiologic conditions in healthy subjects. C1/C2 rotation accounts for approximately half of total head axial rotation. Additionally, C1 undergoes coupled flexion/extension and contralateral bending, in addition to inferior, lateral and posterior translation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Leroy, Agnès Marie Françoise; Bahia, Maria Guiomar de Azevedo; Ehrlacher, Alain; Buono, Vicente Tadeu Lopes
2012-08-01
To build a mathematical model describing the mechanical behavior of NiTi rotary files while they are rotating in a root canal. The file was seen as a beam undergoing large transformations. The instrument was assumed to be rotating steadily in the root canal, and the geometry of the canal was considered as a known parameter of the problem. The formulae of large transformations mechanics then allowed the calculation of the Green-Lagrange strain field in the file. The non-linear mechanical behavior of NiTi was modeled as a continuous piecewise linear function, assuming that the material did not reach plastic deformation. Criteria locating the changes of behavior of NiTi were established and the tension field in the file, and the external efforts applied on it were calculated. The unknown variable of torsion was deduced from the equilibrium equation system using a Coulomb contact law which solved the problem on a cycle of rotation. In order to verify that the model described well reality, three-point bending experiments were managed on superelastic NiTi wires, whose results were compared to the theoretical ones. It appeared that the model gave a good mentoring of the empirical results in the range of bending angles that interested us. Knowing the geometry of the root canal, one is now able to write the equations of the strain and stress fields in the endodontic instrument, and to quantify the impact of each macroscopic parameter of the problem on its response. This should be useful to predict failure of the files under rotating bending fatigue, and to optimize the geometry of the files. Copyright © 2012 Elsevier B.V. All rights reserved.
Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis
Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil
2012-01-01
Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869
Hoffman, Shannon L.; Johnson, Molly B.; Zou, Dequan; Van Dillen, Linda R.
2012-01-01
Patterns of lumbar posture and motion are associated with low back pain (LBP). Research suggests LBP subgroups demonstrate different patterns during common tasks. This study assessed differences in end-range lumbar flexion during two tasks between two LBP subgroups classified according to the Movement System Impairment model. Additionally, the impact of gender differences on subgroup differences was assessed. Kinematic data were collected. Subjects in the Rotation (Rot) and Rotation with Extension (RotExt) LBP subgroups were asked to sit slumped and bend forward from standing. Lumbar end-range flexion was calculated. Subjects reported symptom behavior during each test. Compared to the RotExt subgroup, the Rot subgroup demonstrated greater end-range lumbar flexion during slumped sitting and a trend towards greater end-range lumbar flexion with forward bending. Compared to females, males demonstrated greater end-range lumbar flexion during slumped sitting and forward bending. A greater proportion of people in the Rot subgroup reported symptoms with each test compared to the RotExt subgroup. Males and females were equally likely to report symptoms with each test. Gender differences were not responsible for LBP subgroup differences. Subgrouping people with LBP provides insight into differences in lumbar motion within the LBP population. Results suggesting potential consistent differences across flexion-related tasks support the presence of stereotypical movement patterns that are related to LBP. PMID:22261650
Submillimeter Spectroscopy of the Out-Of Bending State ν_{20} of C_2H_5CN
NASA Astrophysics Data System (ADS)
Pearson, John C.; Brauer, Carolyn S.; Yu, Shanshan; Drouin, Brian J.
2009-06-01
Propionitrile is a well known interstellar molecule that is a closely associated with warm dust near ultra compact H_{II} regions. In these regions the C_2H_5CN column can reach 10^{17} and the rotational temperature often equals the vibrational temperature and exceeds 200 K, populating all the low-lying vibrational states. The rotational spectrum of the third lowest excited vibrational state, the 378 cm^{-1} out-of-plane bending state, ν_{20}, of propionitrile, which was previously identified at millimeter wavelengths in both the laboratory and the interstellar medium, has been characterized to high angular momentum quantum numbers. This state is surprisingly isolated considering its proximity to the overtone of the in-plane bend, 2ν_{13}, the excited torsional state of the in-plane bend, ν_{13}+ν_{21}, and the second excited torsional state, 2ν_{21}, which lie approximately 35 cm^{-1} higher. The only surprising aspect is the presence of significantly larger torsional A-E splitting than observed in either the ground state or the ν_{13} in the absence of a resonance with ν_{21}. Because ν_{20} has been observed in high mass star forming cores in the millimeter, its higher angular momentum lines are known to be a major source of line confusion in high mass star forming cores. The spectrum, constants and determined barriers will be presented.
Solomon, W M; Burrell, K H; Feder, R; Nagy, A; Gohil, P; Groebner, R J
2008-10-01
Measurements of rotation using charge exchange recombination spectroscopy can be affected by the energy dependence of the charge exchange cross section. On DIII-D, the associated correction to the rotation can exceed 100 kms at high temperatures. In reactor-relevant low rotation conditions, the correction can be several times larger than the actual plasma rotation and therefore must be carefully validated. New chords have been added to the DIII-D CER diagnostic to view the counter-neutral-beam line. The addition of these views allows determination of the toroidal rotation without depending on detailed atomic physics calculations, while also allowing experimental characterization of the atomic physics. A database of rotation comparisons from the two views shows that the calculated cross-section correction can adequately describe the measurements, although there is a tendency for "overcorrection." In cases where accuracy better than about 15% is desired, relying on calculation of the cross-section correction may be insufficient.
NASA Astrophysics Data System (ADS)
Lees, R. M.; Xu, Li-Hong; Guislain, B. G.; Reid, E. M.; Twagirayezu, S.; Perry, D. S.; Dawadi, M. B.; Thapaliya, B. P.; Billinghurst, B. E.
2018-01-01
High-resolution Fourier transform spectra of the asymmetric methyl-bending and methyl-stretching bands of CH3SH have been recorded employing synchrotron radiation at the FIR beamline of the Canadian Light Source. Analysis of the torsion-rotation structure and relative intensities has revealed the novel feature that for both bend and stretch the in-plane and out-of-plane modes behave much like a Coriolis-coupled l-doublet pair originating from degenerate E modes of a symmetric top. As the axial angular momentum K increases, the energies of the coupled "l = ±1" modes diverge linearly, with effective Coriolis ζ constants typical for symmetric tops. For the methyl-stretching states, separated at K = 0 by only about 1 cm-1, the assigned sub-bands follow a symmetric top Δ(K - l) = 0 selection rule, with only ΔK = -1 transitions observed to the upper l = -1 in-plane A‧ component and only ΔK = +1 transitions to the lower l = +1 out-of-plane A″ component. The K = 0 separation of the CH3-bending states is larger at 9.1 cm-1 with the l-ordering reversed. Here, both ΔK = +1 and ΔK = -1 transitions are seen for each l-component but with a large difference in relative intensity. Term values for the excited state levels have been fitted to J(J + 1) power-series expansions to obtain substate origins. These have then been fitted to a Fourier model to characterize the torsion-K-rotation energy patterns. For both pairs of vibrational states, the torsional energies display the customary oscillatory behaviour as a function of K and have inverted torsional splittings relative to the ground state. The spectra show numerous perturbations, indicating local resonances with the underlying bath of high torsional levels and vibrational combination and overtone states. The overall structure of the two pairs of bands represents a new regime in which the vibrational energy separations, torsional splittings and shifts due to molecular asymmetry are all of the same order, creating a challenging and complex vibration-torsion-rotation coupling environment.
Tool for Coupling a Torque Wrench to a Round Cable Connector
NASA Technical Reports Server (NTRS)
Hacker, Scott C.; Dean, Richard J.; Burge, Scott W.
2006-01-01
A tool makes it possible to couple a torque wrench to an externally knurled, internally threaded, round cable connector. The purpose served by the tool is to facilitate the tightening of multiple such connectors (or the repeated tightening of the same connector) to repeatable torques. The design of a prior cable-connector/ torque-wrench coupling tool provided for application of the torque-wrench jaws to a location laterally offset from the axis of rotation of the cable connector, making it necessary to correct the torque reading for the offset. Unlike the design of the prior tool, the design of the present tool provides for application of the torque-wrench jaws to a location on the axis of rotation, obviating correction of the torque reading for offset. The present tool (see figure) consists of a split collet containing a slot that provides clearance for inserting and bending the cable, a collet-locking sleeve, a collet-locking nut, and a torque-wrench adaptor that is press-fit onto the collet. Once the collet is positioned on the cable connector, the collet-locking nut is turned to force the collet-locking sleeve over the collet, compressing the collet through engagement of tapered surfaces on the outside of the collet and the inside of the locking sleeve. Because the collet is split and therefore somewhat flexible, this compression forces the collet inward to grip the connector securely. The torque wrench is then applied to the torque-wrench adaptor in the usual manner for torquing a nut or a bolt.
Holewijn, Roderick M; de Kleuver, Marinus; van der Veen, Albert J; Emanuel, Kaj S; Bisschop, Arno; Stadhouder, Agnita; van Royen, Barend J; Kingma, Idsart
2017-08-01
Biomechanical study. Recently, a posterior concave periapical distraction device for fusionless scoliosis correction was introduced. The goal of this study was to quantify the effect of the periapical distraction device on spinal range of motion (ROM) in comparison with traditional rigid pedicle screw-rod instrumentation. Using a spinal motion simulator, 6 human spines were loaded with 4 N m and 6 porcine spines with 2 N m to induce flexion-extension (FE), lateral bending (LB), and axial rotation (AR). ROM was measured in 3 conditions: untreated, periapical distraction device, and rigid pedicle screw-rod instrumentation. The periapical distraction device caused a significant ( P < .05) decrease in ROM of FE (human, -40.0% and porcine, -55.9%) and LB (human, -18.2% and porcine, -17.9%) as compared to the untreated spine, while ROM of AR remained unaffected. In comparison, rigid instrumentation caused a significantly ( P < .05) larger decrease in ROM of FE (human, -80.9% and porcine, -94.0%), LB (human, -75.0% and porcine, -92.2%), and AR (human, -71.3% and porcine, -86.9%). Although no destructive forces were applied, no device failures were observed. Spinal ROM was significantly less constrained by the periapical distraction device compared to rigid pedicle screw-rod instrumentation. Therefore, provided that scoliosis correction is achieved, a more physiological spinal motion is expected after scoliosis correction with the posterior concave periapical distraction device.
Estimation of blade airloads from rotor blade bending moments
NASA Technical Reports Server (NTRS)
Bousman, William G.
1987-01-01
A method is developed to estimate the blade normal airloads by using measured flap bending moments; that is, the rotor blade is used as a force balance. The blade's rotation is calculated in vacuum modes and the airloads are then expressed as an algebraic sum of the mode shapes, modal amplitudes, mass distribution, and frequency properties. The modal amplitudes are identified from the blade bending moments using the Strain Pattern Analysis Method. The application of the method is examined using simulated flap bending moment data that have been calculated for measured airloads for a full-scale rotor in a wind tunnel. The estimated airloads are compared with the wind tunnel measurements. The effects of the number of measurements, the number of modes, and errors in the measurements and the blade properties are examined, and the method is shown to be robust.
Sawicki, R.H.; Sweatt, W.
1985-11-21
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and provides for adjustably bending the light reflecting surface into one of different curvatures depending upon the astigmatism to be corrected and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment to the reinforced side edges of the light reflecting surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawicki, R.H.; Sweatt, W.
1985-11-21
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and provides for adjustably bending the light reflecting surface into one of different curvatures depending upon the astigmatism to be corrected and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment tomore » the reinforced side edges of the light reflecting surface.« less
NASA Astrophysics Data System (ADS)
Kim, Sung-Jin; Cho, Young-Ho; Nam, Hyo-Jin; Bu, Jong Uk
2008-12-01
This paper presents a torsional micromirror detached from PZT actuators (TMD), whose rotational motion is achieved by push bars in the PZT actuators, detached from the micromirror. The push bar mechanism is intended to reduce the bending, tensile and torsional constraints generated by the conventional bending bar mechanism, where the torsional micromirror is attached to the PZT actuators (TMA). We have designed, fabricated and tested the prototypes of TMDs for single-axis and dual-axis rotations, respectively. The single-axis TMD generates a static rotational angle of 6.1° at 16 Vdc, which is six times larger than that of the single-axis TMA, 0.9°. However, the rotational response curve of TMD shows hysteresis and zero offset due to the static friction from the initial contact force between the cover and the push bar in the PZT actuator. We have shown that 63.2% of the hysteresis is reduced by eliminating the initial contact force of the PZT actuator. The dual-axis TMD generates static rotational angles of 5.5° and 4.7° in the x-axis and y-axis, respectively, at 16 Vdc. The measured resonant frequencies of the dual-axis TMD are 2.1 ± 0.1 kHz in the x-axis and 1.7 ± 0.1 kHz in the y-axis. The dual-axis TMD shows stable operation without severe wear for 21.6 million cycles driven by the 16 Vp-p sinusoidal wave signal at room temperature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, G. Barratt, E-mail: barratt@mit.edu; Baraban, Joshua H.; Field, Robert W.
2014-10-07
A full-dimensional Franck-Condon calculation has been applied to the A{sup ~} {sup 1}A{sub u}—X{sup ~1}Σ{sub g}{sup +} transition in acetylene in the harmonic normal mode basis. Details of the calculation are discussed in Part I of this series. To our knowledge, this is the first full-dimensional Franck-Condon calculation on a tetra-atomic molecule undergoing a linear-to-bent geometry change. In the current work, the vibrational intensity factors for levels involving excitation in ungerade vibrational modes are evaluated. Because the Franck-Condon integral accumulates away from the linear geometry, we have been able to treat the out-of-plane component of trans bend (ν{sub 4}{sup ′′}) in themore » linear X{sup ~} state in the rotational part of the problem, restoring the χ Euler angle and the a-axis Eckart conditions. A consequence of the Eckart conditions is that the out-of-plane component of ν{sub 4}{sup ′′} does not participate in the vibrational overlap integral. This affects the structure of the coordinate transformation and the symmetry of the vibrational wavefunctions used in the overlap integral, and results in propensity rules involving the bending modes of the X{sup ~} state that were not previously understood. We explain the origin of some of the unexpected propensities observed in IR-UV laser-induced fluorescence spectra, and we calculate emission intensities from bending levels of the A{sup ~} state into bending levels of the X{sup ~} state, using normal bending mode and local bending mode basis sets. Our calculations also reveal Franck-Condon propensities for the Cartesian components of the cis bend (ν{sub 5}{sup ′′}), and we predict that the best A{sup ~}-state vibrational levels for populating X{sup ~}-state levels with large amplitude bending motion localized in a single C–H bond (the acetylene↔vinylidene isomerization coordinate) involve a high degree of excitation in ν{sub 6}{sup ′} (cis-bend). Mode ν{sub 4}{sup ′} (torsion) populates levels with large amplitude counter-rotational motion of the two hydrogen atoms.« less
Basic principles and recent observations of rotationally sampled wind
NASA Technical Reports Server (NTRS)
Connell, James R.
1995-01-01
The concept of rotationally sampled wind speed is described. The unusual wind characteristics that result from rotationally sampling the wind are shown first for early measurements made using an 8-point ring of anemometers on a vertical plane array of meteorological towers. Quantitative characterization of the rotationally sampled wind is made in terms of the power spectral density function of the wind speed. Verification of the importance of the new concept is demonstrated with spectral analyses of the response of the MOD-OA blade flapwise root bending moment and the corresponding rotational analysis of the wind measured immediately upwind of the MOD-OA using a 12-point ring of anemometers on a 7-tower vertical plane array. The Pacific Northwest Laboratory (PNL) theory of the rotationally sampled wind speed power spectral density function is tested successfully against the wind spectrum measured at the MOD-OA vertical plane array. A single-tower empirical model of the rotationally sampled wind speed is also successfully tested against the measurements from the full vertical plane array. Rotational measurements of the wind velocity with hotfilm anemometers attached to rotating blades are shown to be accurate and practical for research on winds at the blades of wind turbines. Some measurements at the rotor blade of a MOD-2 turbine using the hotfilm technique in a pilot research program are shown. They are compared and contrasted to the expectations based upon application of the PNL theory of rotationally sampled wind to the MOD-2 size and rotation rate but without teeter, blade bending, or rotor induction accounted for. Finally, the importance of temperature layering and of wind modifications due to flow over complex terrain is demonstrated by the use of hotfilm anemometer data, and meteorological tower and acoustic doppler sounder data from the MOD-2 site at Goodnoe Hills, Washington.
Mechanics of Constriction during Cell Division: A Variational Approach
Almendro-Vedia, Victor G.; Monroy, Francisco; Cao, Francisco J.
2013-01-01
During symmetric division cells undergo large constriction deformations at a stable midcell site. Using a variational approach, we investigate the mechanical route for symmetric constriction by computing the bending energy of deformed vesicles with rotational symmetry. Forces required for constriction are explicitly computed at constant area and constant volume, and their values are found to be determined by cell size and bending modulus. For cell-sized vesicles, considering typical bending modulus of , we calculate constriction forces in the range . The instability of symmetrical constriction is shown and quantified with a characteristic coefficient of the order of , thus evidencing that cells need a robust mechanism to stabilize constriction at midcell. PMID:23990888
Shojaei, Iman; Salt, Elizabeth G; Hooker, Quenten; Van Dillen, Linda R; Bazrgari, Babak
2017-01-01
Prior studies have reported differences in lumbo-pelvic kinematics during a trunk forward bending and backward return task between individuals with and without chronic low back pain; yet, the literature on lumbo-pelvic kinematics of patients with acute low back pain is scant. Therefore, the purpose of this study was set to investigate lumbo-pelvic kinematics in this cohort. A case-control study was conducted to investigate the differences in pelvic and thoracic rotation along with lumbar flexion as well as their first and second time derivatives between females with and without acute low back pain. Participants in each group completed one experimental session wherein they performed trunk forward bending and backward return at self-selected and fast paces. Compared to controls, individuals with acute low back pain had larger pelvic range of rotations and smaller lumbar range of flexions. Patients with acute low back pain also adopted a slower pace compared to asymptomatic controls which was reflected in smaller maximum values for angular velocity, deceleration and acceleration of lumbar flexion. Irrespective of participant group, smaller pelvic range of rotation and larger lumbar range of flexion were observed in younger vs. older participants. Reduced lumbar range of flexion and slower task pace, observed in patients with acute low back pain, may be the result of a neuromuscular adaptation to reduce the forces and deformation in the lower back tissues and avoid pain aggravation. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Anderson, David T.; Davis, Scott; Nesbitt, David J.
1996-04-01
High resolution near infrared spectra of the two lowest frequency intermolecular modes in HF-stretch excited states of (HF)2 have been characterized using a slit-jet infrared spectrometer. In the spectral region surveyed, ten vibration-rotation-tunneling (VRT) bands are observed and assigned to the low frequency ``van der Waals stretch'' (ν4) and ``geared bend'' (ν5) intermolecular modes, in combination with either the hydrogen bond acceptor (ν1) or donor (ν2) high-frequency intramolecular HF stretches. Analysis of the rotationally resolved spectra provide intermolecular frequencies, rotational constants, tunneling splittings, and predissociation rates for the ν4/ν5 intermolecular excited states. The intermolecular vibrational frequencies in the combination states display a systematic dependence on intramolecular redshift that allows far-IR intermolecular frequencies to be reliably extrapolated from the near-IR data. Approximately tenfold increases in the hydrogen bond interconversion tunneling splittings with either ν4 or ν5 excitation indicate that both intermolecular modes correlate strongly to the tunneling coordinate. The high resolution VRT line shapes reveal mode specific predissociation broadening sensitive predominantly to intramolecular excitation, with weaker but significant additional effects due to low frequency intermolecular excitation. Analysis of the high resolution spectroscopic data for these ν4 and ν5 combination bands suggests strong state mixing between what has previously been considered van der Waals stretch and geared bend degrees of freedom.
Laser Doppler measurements of laminar and turbulent flow in a pipe bend
NASA Technical Reports Server (NTRS)
Enayet, M. M.; Gibson, M. M.; Taylor, A. M. K. P.; Yianneskis, M.
1982-01-01
The streamwise components of velocity in the flow through a ninety degree bend of circular cross section for which the ratio of radius of curvature to diameter is 2.8 were measured. The development of strong pressure driven secondary flow in the form of a pair of counter rotating vortices in the steamwise direction is shown. Refractive index matching at the fluid wall interface was not employed; the displacement of the measurement volume due to refraction is allowed for in simple geometrical calculations.
NASA Technical Reports Server (NTRS)
Subrahmanyam, K. B.; Kaza, K. R. V.
1986-01-01
The governing coupled flapwise bending, edgewise bending, and torsional equations are derived including third-degree geometric nonlinear elastic terms by making use of the geometric nonlinear theory of elasticity in which the elongations and shears are negligible compared to unity. These equations are specialized for blades of doubly symmetric cross section with linear variation of pretwist over the blade length. The nonlinear steady state equations and the linearized perturbation equations are solved by using the Galerkin method, and by utilizing the nonrotating normal modes for the shape functions. Parametric results obtained for various cases of rotating blades from the present theoretical formulation are compared to those produced from the finite element code MSC/NASTRAN, and also to those produced from an in-house experimental test rig. It is shown that the spurious instabilities, observed for thin, rotating blades when second degree geometric nonlinearities are used, can be eliminated by including the third-degree elastic nonlinear terms. Furthermore, inclusion of third degree terms improves the correlation between the theory and experiment.
Magnetic fish-robot based on multi-motion control of a flexible magnetic actuator.
Kim, Sung Hoon; Shin, Kyoosik; Hashi, Shuichiro; Ishiyama, Kazushi
2012-09-01
This paper presents a biologically inspired fish-robot driven by a single flexible magnetic actuator with a rotating magnetic field in a three-axis Helmholtz coil. Generally, magnetic fish-robots are powered by alternating and gradient magnetic fields, which provide a single motion such as bending the fish-robot's fins. On the other hand, a flexible magnetic actuator driven by an external rotating magnetic field can create several gaits such as the bending vibration, the twisting vibration, and their combination. Most magnetic fish-like micro-robots do not have pectoral fins on the side and are simply propelled by the tail fin. The proposed robot can swim and perform a variety of maneuvers with the addition of pectoral fins and control of the magnetic torque direction. In this paper, we find that the robot's dynamic actuation correlates with the magnetic actuator and the rotating magnetic field. The proposed robot is also equipped with new features, such as a total of six degrees of freedom, a new control method that stabilizes posture, three-dimensional swimming, a new velocity control, and new turning abilities.
The Arabidopsis WAVY GROWTH 2 protein modulates root bending in response to environmental stimuli.
Mochizuki, Susumu; Harada, Akiko; Inada, Sayaka; Sugimoto-Shirasu, Keiko; Stacey, Nicola; Wada, Takuji; Ishiguro, Sumie; Okada, Kiyotaka; Sakai, Tatsuya
2005-02-01
To understand how the direction of root growth changes in response to obstacles, light, and gravity, we characterized an Arabidopsis thaliana mutant, wavy growth 2 (wav2), whose roots show a short-pitch pattern of wavy growth on inclined agar medium. The roots of the wav2 mutant bent with larger curvature than those of the wild-type seedlings in wavy growth and in gravitropic and phototropic responses. The cell file rotations of the root epidermis of wav2-1 in the wavy growth pattern were enhanced in both right-handed and left-handed rotations. WAV2 encodes a protein belonging to the BUD EMERGENCE 46 family with a transmembrane domain at the N terminus and an alpha/beta-hydrolase domain at the C terminus. Expression analyses showed that mRNA of WAV2 was expressed strongly in adult plant roots and seedlings, especially in the root tip, the cell elongation zone, and the stele. Our results suggest that WAV2 is not involved in sensing environmental stimuli but that it negatively regulates stimulus-induced root bending through inhibition of root tip rotation.
Daniels, Alan H; Paller, David J; Koruprolu, Sarath; Palumbo, Mark A; Crisco, Joseph J
2013-01-01
Biomechanical investigations of spinal motion preserving implants help in the understanding of their in vivo behavior. In this study, we hypothesized that the lumbar spine with implanted total spinal segment replacement (TSSR) would exhibit decreased dynamic stiffness and more rapid energy absorption compared to native functional spinal units under simulated physiologic motion when tested with the pendulum system. Five unembalmed, frozen human lumbar functional spinal units were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Flexuspine total spinal segment replacement implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°; resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. The total spinal segment replacement reached equilibrium with significantly fewer cycles to equilibrium compared to the intact functional spinal unit at all loads in flexion (p<0.011), and at loads of 385 N and 488 N in lateral bending (p<0.020). Mean bending stiffness in flexion, extension, and lateral bending increased with increasing load for both the intact functional spinal unit and total spinal segment replacement constructs (p<0.001), with no significant differences in stiffness between the intact functional spinal unit and total spinal segment replacement in any of the test modes (p>0.18). Lumbar functional spinal units with implanted total spinal segment replacement were found to have similar dynamic bending stiffness, but absorbed energy at a more rapid rate than intact functional spinal units during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices is not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions.
Daniels, Alan H.; Paller, David J.; Koruprolu, Sarath; Palumbo, Mark A.; Crisco, Joseph J.
2013-01-01
Background Biomechanical investigations of spinal motion preserving implants help in the understanding of their in vivo behavior. In this study, we hypothesized that the lumbar spine with implanted total spinal segment replacement (TSSR) would exhibit decreased dynamic stiffness and more rapid energy absorption compared to native functional spinal units under simulated physiologic motion when tested with the pendulum system. Methods Five unembalmed, frozen human lumbar functional spinal units were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Flexuspine total spinal segment replacement implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°; resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. Results The total spinal segment replacement reached equilibrium with significantly fewer cycles to equilibrium compared to the intact functional spinal unit at all loads in flexion (p<0.011), and at loads of 385 N and 488 N in lateral bending (p<0.020). Mean bending stiffness in flexion, extension, and lateral bending increased with increasing load for both the intact functional spinal unit and total spinal segment replacement constructs (p<0.001), with no significant differences in stiffness between the intact functional spinal unit and total spinal segment replacement in any of the test modes (p>0.18). Conclusions Lumbar functional spinal units with implanted total spinal segment replacement were found to have similar dynamic bending stiffness, but absorbed energy at a more rapid rate than intact functional spinal units during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices is not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions. PMID:23451222
Daniels, Alan H; Paller, David J; Koruprolu, Sarath; McDonnell, Matthew; Palumbo, Mark A; Crisco, Joseph J
2012-11-01
Biomechanical cadaver investigation. To examine dynamic bending stiffness and energy absorption of the lumbar spine with and without implanted total disc replacement (TDR) under simulated physiological motion. The pendulum testing system is capable of applying physiological compressive loads without constraining motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. Five unembalmed, frozen human lumbar FSUs were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Synthes ProDisc-L TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5º resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N·m/º) was calculated and compared for each testing mode. In flexion/extension, the TDR constructs reached equilibrium with significantly (P < 0.05) fewer cycles than the intact FSU with compressive loads of 282 N, 385 N, and 488 N. Mean dynamic bending stiffness in flexion, extension, and lateral bending increased significantly with increasing load for both the intact FSU and TDR constructs (P < 0.001). In flexion, with increasing compressive loading from 181 N to 488 N, the bending stiffness of the intact FSUs increased from 4.0 N·m/º to 5.5 N·m/º, compared with 2.1 N·m/º to 3.6 N·m/º after TDR implantation. At each compressive load, the intact FSU was significantly stiffer than the TDR (P < 0.05). Lumbar FSUs with implanted TDR were found to be less stiff, but absorbed more energy during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion-preserving devices are not fully known, these results provide further insight into the biomechanical behavior of these devices under approximated physiological loading conditions.
A 4-node assumed-stress hybrid shell element with rotational degrees of freedom
NASA Technical Reports Server (NTRS)
Aminpour, Mohammad A.
1990-01-01
An assumed-stress hybrid/mixed 4-node quadrilateral shell element is introduced that alleviates most of the deficiencies associated with such elements. The formulation of the element is based on the assumed-stress hybrid/mixed method using the Hellinger-Reissner variational principle. The membrane part of the element has 12 degrees of freedom including rotational or drilling degrees of freedom at the nodes. The bending part of the element also has 12 degrees of freedom. The bending part of the element uses the Reissner-Mindlin plate theory which takes into account the transverse shear contributions. The element formulation is derived from an 8-node isoparametric element. This process is accomplished by assuming quadratic variations for both in-plane and out-of-plane displacement fields and linear variations for both in-plane and out-of-plane rotation fields along the edges of the element. In addition, the degrees of freedom at midside nodes are approximated in terms of the degrees of freedom at corner nodes. During this process the rotational degrees of freedom at the corner nodes enter into the formulation of the element. The stress field are expressed in the element natural-coordinate system such that the element remains invariant with respect to node numbering.
Simulated Single Tooth Bending of High Temperature Alloys
NASA Technical Reports Server (NTRS)
Handschuh, Robert, F.; Burke, Christopher
2012-01-01
Future unmanned space missions will require mechanisms to operate at extreme conditions in order to be successful. In some of these mechanisms, very high gear reductions will be needed to permit very small motors to drive other components at low rotational speed with high output torque. Therefore gearing components are required that can meet the mission requirements. In mechanisms such as this, bending fatigue strength capacity of the gears is very important. The bending fatigue capacity of a high temperature, nickel-based alloy, typically used for turbine disks in gas turbine engines and two tool steel materials with high vanadium content, were compared to that of a typical aerospace alloy-AISI 9310. Test specimens were fabricated by electro-discharge machining without post machining processing. Tests were run at 24 and at 490 C. As test temperature increased from 24 to 490 C the bending fatigue strength was reduced by a factor of five.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Water, Steven van de, E-mail: s.vandewater@erasmusmc.nl; Valli, Lorella; Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna
Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was alsomore » varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.« less
Ni, Haijian; Zhu, Xiaodong; Li, Ming
2015-01-01
Purpose To clarify if CCI or FBCI could fully eliminate the influence of curve flexibility on the coronal correction rate. Methods We reviewed medical record of all thoracic curve AIS cases undergoing posterior spinal fusion with all pedicle screw systems from June 2011 to July 2013. Radiographical data was collected and calculated. Student t test, Pearson correlation analysis and linear regression analysis were used to analyze the data. Results 60 were included in this study. The mean age was 14.7y (10-18y) with 10 males (17%) and 50 females (83%). The average Risser sign was 2.7. The mean thoracic Cobb angle before operation was 51.9°. The mean bending Cobb angle was 27.6° and the mean fulcrum bending Cobb angle was 17.4°. The mean Cobb angle at 2 week after surgery was 16.3°. The Pearson correlation coefficient r between CCI and BFR was -0.856(P<0.001), and between FBCI and FFR was -0.728 (P<0.001). A modified FBCI (M-FBCI) = (CR-0.513)/BFR or a modified CCI (M-CCI) = (CR-0.279)/FFR was generated by curve estimation has no significant correlation with FFR (r=-0.08, p=0.950) or with BFR (r=0.123, p=0.349). Conclusions Fulcrum-bending radiographs may better predict the outcome of AIS coronal correction than bending radiographs in thoracic curveAIS patients. Neither CCI nor FBCI can fully eliminate the impact of curve flexibility on the outcome of correction. A modified CCI or FBCI can better evaluating the corrective effects of different surgical techniques or instruments. PMID:25984945
Yang, Changwei; Sun, Xiaofei; Li, Chao; Ni, Haijian; Zhu, Xiaodong; Yang, Shichang; Li, Ming
2015-01-01
To clarify if CCI or FBCI could fully eliminate the influence of curve flexibility on the coronal correction rate. We reviewed medical record of all thoracic curve AIS cases undergoing posterior spinal fusion with all pedicle screw systems from June 2011 to July 2013. Radiographical data was collected and calculated. Student t test, Pearson correlation analysis and linear regression analysis were used to analyze the data. 60 were included in this study. The mean age was 14.7 y (10-18 y) with 10 males (17%) and 50 females (83%). The average Risser sign was 2.7. The mean thoracic Cobb angle before operation was 51.9°. The mean bending Cobb angle was 27.6° and the mean fulcrum bending Cobb angle was 17.4°. The mean Cobb angle at 2 week after surgery was 16.3°. The Pearson correlation coefficient r between CCI and BFR was -0.856(P<0.001), and between FBCI and FFR was -0.728 (P<0.001). A modified FBCI (M-FBCI) = (CR-0.513)/BFR or a modified CCI (M-CCI) = (CR-0.279)/FFR was generated by curve estimation has no significant correlation with FFR (r=-0.08, p=0.950) or with BFR (r=0.123, p=0.349). Fulcrum-bending radiographs may better predict the outcome of AIS coronal correction than bending radiographs in thoracic curveAIS patients. Neither CCI nor FBCI can fully eliminate the impact of curve flexibility on the outcome of correction. A modified CCI or FBCI can better evaluating the corrective effects of different surgical techniques or instruments.
Zhu, Q A; Park, Y B; Sjovold, S G; Niosi, C A; Wilson, D C; Cripton, P A; Oxland, T R
2008-02-01
Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in axial rotation (71 +/- 25 N), followed by extension (27 +/- 35 N) and lateral bending (25 +/- 28 N), and they were most repeatable in axial rotation (coefficient of variation, 5 per cent). The EAS accuracy was about 20 per cent in the direct accuracy assessment and about 30 per cent in the disarticulated accuracy test. The latter was very similar to the Tekscan accuracy in the same test. Virtual facet loads (r.m.s.) were small in axial rotation (12 N) and lateral bending (20 N), but relatively large in flexion (34 N) and extension (35 N). The results suggested that the bilateral EAS model could be used to determine the facet joint contact forces in axial rotation but may result in considerable error in flexion, extension, and lateral bending.
NASA Astrophysics Data System (ADS)
Gomez, F.; Jaafar, R.; Abdallah, C.; Karam, G.
2012-12-01
The Lebanese Restraining Bend (LRB) is a ~200-km-long bend in the central part of the Dead Sea Fault system (DSFS). As with other large restraining bends, this part of the transform is characterized by more complicated structure than other parts. Additionally, results from recent GPS studies have documented slower velocities north of the LRB than are observed along the southern DSFS to the south. In an effort to understand how strain is transferred through the LRB, this study analyzes improved GPS velocities within the central DSFS based on new data and additional stations. Despite relatively modest rates of seismicity, the Dead Sea Fault system (DSFS) has a historically documented record of producing large and devastating earthquakes. Hence, geodetic measurements of crustal deformation may provide key constraints on processes of strain accumulation that may not be evident in instrumentally recorded seismicity. Within the LRB, the transform splays into two prominent strike-slip faults: The through-going Yammouneh fault and the Serghaya fault. The latter appears to terminate in the Anti-Lebanon Mountains. Additionally, some oblique plate motion is accommodated by thrusting along the coast of Lebanon. This study used GPS observations from survey-mode GPS sites, as well as continuous GPS stations in the region. In total, 22 GPS survey sites have been measured in Lebanon between 2002 and 2010, along with GPS data from the adjacent area. Elastic models are used for initial assessment of fault slip rates. Incorporating two major strike-slip faults, as well as an offshore thrust fault, this modeling suggests left-lateral slip rates of 3.8 mm/yr and 1.1 mm/yr for the Yammouneh and Serghaya faults, respectively. The GPS survey network has sufficient density for analyzing velocity gradients in an effort to quantify tectonic strains and rotations. The velocity gradients suggest that differential rotations play a role in accommodating some plate motion.
Lapsiwala, Samir B; Anderson, Paul A; Oza, Ashish; Resnick, Daniel K
2006-03-01
We performed a biomechanical comparison of several C1 to C2 fixation techniques including crossed laminar (intralaminar) screw fixation, anterior C1 to C2 transarticular screw fixation, C1 to 2 pedicle screw fixation, and posterior C1 to C2 transarticular screw fixation. Eight cadaveric cervical spines were tested intact and after dens fracture. Four different C1 to C2 screw fixation techniques were tested. Posterior transarticular and pedicle screw constructs were tested twice, once with supplemental sublaminar cables and once without cables. The specimens were tested in three modes of loading: flexion-extension, lateral bending, and axial rotation. All tests were performed in load and torque control. Pure bending moments of 2 nm were applied in flexion-extension and lateral bending, whereas a 1 nm moment was applied in axial rotation. Linear displacements were recorded from extensometers rigidly affixed to the C1 and C2 vertebrae. Linear displacements were reduced to angular displacements using trigonometry. Adding cable fixation results in a stiffer construct for posterior transarticular screws. The addition of cables did not affect the stiffness of C1 to C2 pedicle screw constructs. There were no significant differences in stiffness between anterior and posterior transarticular screw techniques, unless cable fixation was added to the posterior construct. All three posterior screw constructs with supplemental cable fixation provide equal stiffness with regard to flexion-extension and axial rotation. C1 lateral mass-C2 intralaminar screw fixation restored resistance to lateral bending but not to the same degree as the other screw fixation techniques. All four screw fixation techniques limit motion at the C1 to 2 articulation. The addition of cable fixation improves resistance to flexion and extension for posterior transarticular screw fixation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, Brandon; Rocha da Costa, Leandro Jose; Poirel, Dominique
Our study details the derivation of the nonlinear equations of motion for the axial, biaxial bending and torsional vibrations of an aeroelastic cantilever undergoing rigid body (pitch) rotation at the base. The primary attenstion is focussed on the geometric nonlinearities of the system, whereby the aeroelastic load is modeled by the theory of linear quasisteady aerodynamics. This modelling effort is intended to mimic the wind-tunnel experimental setup at the Royal Military College of Canada. While the derivation closely follows the work of Hodges and Dowell [1] for rotor blades, this aeroelastic system contains new inertial terms which stem from themore » fundamentally different kinematics than those exhibited by helicopter or wind turbine blades. Using the Hamilton’s principle, a set of coupled nonlinear partial differential equations (PDEs) and an ordinary differential equation (ODE) are derived which describes the coupled axial-bending-bending-torsion-pitch motion of the aeroelastic cantilever with the pitch rotation. The finite dimensional approximation of the coupled system of PDEs are obtained using the Galerkin projection, leading to a coupled system of ODEs. Subsequently, these nonlinear ODEs are solved numerically using the built-in MATLAB implicit ODE solver and the associated numerical results are compared with those obtained using Houbolt’s method. It is demonstrated that the system undergoes coalescence flutter, leading to a limit cycle oscillation (LCO) due to coupling between the rigid body pitching mode and teh flexible mode arising from the flapwise bending motion.« less
Experimental Study on the Propulsion Performance of the M-shape flapping wing’s bending angle
NASA Astrophysics Data System (ADS)
Chen, Jingxian; Nie, Xiaofang; Zhou, Ximing
2017-10-01
To study the the effect of flapping wing with different bending angles α on the thrust, in this paper, 9 M-shape flapping wing models with different bending angles, ranging for 0° to 22°, were designed. The rotating arm experiment was adopted to conduct the thrust test on the flapping wing models with different bending angels under the wind speed of 15m/s. The result shows that the span-wise flapping wing’s curvature could rectify the airflow, the proper curvature could prevent the span-wise airflow at the surface the flapping wing and leads the airflow towards backward, the amount of air pushed backwards by the flapping wing is larger, therefore the value of thrust is increased; As well as the rectification of M-shape flapping wing increases the thrust value, the flapping wing’s form drag also increased due to the bending angle. According to the results of the experiment, when the bending angle is less than 12°, the increment of the thrust is larger than the decrease of the form drag, so the thrust value increases gradually. However, when the bending angle is larger than 12°, the increment of the thrust is less than the decrease of the form drag, so the thrust value decreases. The thrust value is the largest when the bending angle is 12°.
CSM docked DAP/orbital assembly bending interaction-axial case
NASA Technical Reports Server (NTRS)
Turnbull, J. F.; Jones, J. E.
1972-01-01
A digital autopilot which can provide attitude control for the entire Skylab orbital assembly using the service module reaction control jets is described. An important consideration is the potential interaction of the control system with the bending modes of the orbital assembly. Two aspects of this potential interaction were considered. The first was the possibility that bending induced rotations feeding back through the attitude sensor into the control system could produce an instability or self-sustained oscillation. The second was whether the jet activity commanded by the control system could produce excessive loads at any of the critical load points of the orbital assembly. Both aspects were studied by using analytic techniques and by running simulations on the all-digital simulator.
NASA Astrophysics Data System (ADS)
Goldring, Nicholas
The impending Advanced Photon Source Upgrade (APS-U) will introduce a hard x-ray source that is set to surpass the current APS in brightness and coherence by two to three orders of magnitude. To achieve this, the storage ring light source will be equipped with a multi-bend achromat (MBA) lattice. In order to fully exploit and preserve the integrity of new beams actualized by upgraded storage ring components, improved beamline optics must also be introduced. The design process of new optics for the APS-U and other fourth generation synchrotrons involves the challenge of accommodating unprecedented heat loads. This dissertation presents an ex-situ analysis of heat load deformation and the subsequent mechanical bending correction of a 400 mm long, grazing-incidence, H2O side-cooled, reflecting mirror subjected to x-ray beams produced by the APS-U undulator source. Bending correction is measured as the smallest rms slope error, sigmarms, that can be resolved over a given length of the heat deformed geometry due to mechanical bending. Values of sigmarms in the <0.1 microrad regime represent a given mirror length over which incident x-ray beams from modern sources can be reflected without significant loss of quality. This study assumes a perfectly flat mirror surface and does not account for finish errors or other contributions to sigmarms beyond the scope of thermal deformation and elastic bending. The methodology of this research includes finite element analysis (FEA) employed conjointly with an analytical solution for mechanical bending deflection by means of an end couple. Additionally, the study will focus on two beam power density profiles predicted by the APS-U which were created using the software SRCalc. The profiles account for a 6 GeV electron beam with second moment widths of 0.058 and 0.011 mm in the x- and y- directions respectively; the electron beam is passed through a 4.8 m long, 28 mm period APS-U undulator which produces the x-ray beam incident at a 3 mrad grazing angle on the flat mirror surface for both cases. The first power density profile is the most extreme case created by the undulator at it's closest gap with a critical energy of 3 keV (k y=2.459); the second profile is generated for the case in which the undulator is tuned to emit at 8 keV (ky=1.026). The 3 keV case is of particular interest as it represents one of the most intense peak heat loads predicted to be incident on first optics at the APS-U. The FEA results revealed that the deflection due to the 3 keV heat load yields a 10.9 microrad rms slope error over the full mirror length. The projected correction via the elastic bending of the substrate yields a 0.10 microrad sigma rms within the center longitudinal 300 mm. The FEA also predicts that the 8 keV heat load deflection can be corrected to a sigma rms of 0.11 microrad within the center 300 mm from 1.50 microrad over the entire length. Attempts to optimize the end couple to correct over the entire 400 mm mirror length were unable to resolve the heat load deflection rms slope error to within a <0.1 microrad value for either case. However, if a larger corrected surface is required, a longer mirror can be implemented so as to absorb the heat load of a larger beam than necessary which can then be cut by an aperture to the desired size and energy range.
Kinugasa, Ryuta; Taniguchi, Keigo; Yamamura, Naoto; Fujimiya, Mineko; Katayose, Masaki; Takagi, Shu; Edgerton, V Reggie; Sinha, Shantanu
2018-03-12
The in vitro unconstrained Achilles tendon is nearly straight, while in vivo experiments reveal that the proximal region of the Achilles tendon, adjacent to Kager's fat pad, bends ventrally during plantarflexion but remains nearly straight during dorsiflexion. Tendon bending is an important factor in determining the displacement of the foot compared to the shortening of the muscle fibers. The objective of this study was to elucidate the various mechanisms that could cause tendon bending, which currently remain unknown. Examination of Thiel-embalmed cadavers, with preservation of native articular joint mobility, revealed that the Achilles tendon still bent ventrally even when its surrounding tissues, including the skin surface, Kager's fat pad, and distal portions of the soleus muscle were removed. Shear modulus and collagen fiber orientation were distributed homogeneously with respect to the longitudinal line of the tendon, minimizing their causative contributions to the bending. Given that tendon bending is not caused by either the nature of the deformations of the tissues surrounding the Achilles tendon or its physical properties, we conclude that it results from the geometric architecture of the Achilles tendon and its configuration with respect to the surrounding tissues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Y.; Keller, J.; LaCava, W.
2012-09-01
This computational work investigates planetary gear load sharing of three-mount suspension wind turbine gearboxes. A three dimensional multibody dynamic model is established, including gravity, bending moments, fluctuating mesh stiffness, nonlinear tooth contact, and bearing clearance. A flexible main shaft, planetary carrier, housing, and gear shafts are modeled using reduced degrees-of-freedom through modal compensation. This drivetrain model is validated against the experimental data of Gearbox Reliability Collaborative for gearbox internal loads. Planet load sharing is a combined effect of gravity, bending moment, bearing clearance, and input torque. Influences of each of these parameters and their combined effects on the resulting planetmore » load sharing are investigated. Bending moments and gravity induce fundamental excitations in the rotating carrier frame, which can increase gearbox internal loads and disturb load sharing. Clearance in carrier bearings reduces the bearing load carrying capacity and thus the bending moment from the rotor can be transmitted into gear meshes. With bearing clearance, the bending moment can cause tooth micropitting and can induce planet bearing fatigue, leading to reduced gearbox life. Planet bearings are susceptible to skidding at low input torque.« less
NASA Technical Reports Server (NTRS)
Schwenke, David W.; Langhoff, Stephen R. (Technical Monitor)
1995-01-01
A description is given of an algorithm for computing ro-vibrational energy levels for tetratomic molecules. The expressions required for evaluating transition intensities are also given. The variational principle is used to determine the energy levels and the kinetic energy operator is simple and evaluated exactly. The computational procedure is split up into the determination of one dimensional radial basis functions, the computation of a contracted rotational-bending basis, followed by a final variational step coupling all degrees of freedom. An angular basis is proposed whereby the rotational-bending contraction takes place in three steps. Angular matrix elements of the potential are evaluated by expansion in terms of a suitable basis and the angular integrals are given in a factorized form which simplifies their evaluation. The basis functions in the final variational step have the full permutation symmetries of the identical particles. Sample results are given for HCCH and BH3.
Vibration characteristics of a steadily rotating slender ring
NASA Technical Reports Server (NTRS)
Lallman, F. J.
1980-01-01
Partial differential equations are derived to describe the structural vibrations of a uniform homogeneous ring which is very flexible because the radius is very large compared with the cross sectional dimensions. Elementary beam theory is used and small deflections are assumed in the derivation. Four sets of structural modes are examined: bending and compression modes in the plane of the ring; bending modes perpendicular to the plane of the ring; and twisting modes about the centroid of the ring cross section. Spatial and temporal characteristics of these modes, presented in terms of vibration frequencies and ratios between vibration amplitudes, are demonstrated in several figures. Given a sufficiently high rotational rate, the dynamics of the ring approach those of a vibrating string. In this case, the velocity of traveling wave in the material of the ring approaches in velocity of the material relative to inertial space, resulting in structural modes which are almost stationary in space.
Deng, Ang; Zhang, Hong-Qi; Tang, Ming-Xing; Liu, Shao-Hua; Wang, Yu-Xiang; Gao, Qi-Le
2017-01-01
OBJECTIVE The objective of this study was to evaluate the clinical efficacy of posterior-only surgical correction of dystrophic scoliosis in patients with neurofibromatosis Type 1 (NF1) using a multiple anchor point method (MAPM). METHODS From 2005 to 2014, 31 patients (mean age 13.5 years old, range 10-22 years old) suffering from dystrophic scoliosis associated with NF1 underwent posterior-only surgical correction using a MAPM. The apex of the deformity was thoracic (n = 25), thoracolumbar (n = 4), and lumbar (n = 2). The mean preoperative coronal Cobb angle was 69.1° (range 48.9°-91.4°). The mean Cobb angle on the side-bending radiograph of the convex side was 58.2° (range 40°-79.8°). The mean flexibility and apical vertebral rotation (AVR) were 15.6% (range 8.3%-28.2%) and 2.5° (range 2°-3°), respectively. The mean angle of sagittal kyphosis was 58.3° (range 34.1°-79.6°). RESULTS The mean follow-up period was 53 months (range 12-96 months). The mean postoperative coronal Cobb angle was 27.4° (range 16.3°-46.7°). Postoperatively, the mean AVR and angle of sagittal kyphosis were 1.2° (range 1°-2°) and 22.4° (range 4.2°-36.3°), respectively. All patients showed good correction of all indices postoperatively. The mean postoperative correction rate was 58.7% (range 46.3%-74.1%). At the final follow-up evaluation, the corrective loss rate of the Cobb angle was only 2.3%. Only 1 patient required revision surgery. No severe complications such as spinal cord, neural, or large vascular injury occurred during the operation. CONCLUSIONS Posterior-only surgical correction of dystrophic scoliosis in patients with NF1 using a MAPM could yield satisfactory clinical efficacy of correction and fusion.
Correction of rotational distortion for catheter-based en face OCT and OCT angiography
Ahsen, Osman O.; Lee, Hsiang-Chieh; Giacomelli, Michael G.; Wang, Zhao; Liang, Kaicheng; Tsai, Tsung-Han; Potsaid, Benjamin; Mashimo, Hiroshi; Fujimoto, James G.
2015-01-01
We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm. PMID:25361133
Statistical-Mechanical Studies of the Collective Binding of Proteins to DNA
NASA Astrophysics Data System (ADS)
Zhang, Houyin
My dissertation work focuses on the microscopic statistical-mechanical studies of DNA-protein interactions and mainly comprises of three projects. In living cells, binding of proteins to DNA controls gene expression and packaging of the genome. Single-DNA stretching and twisting experiments provide a powerful tool to detect binding of proteins, via detection of their modification of DNA mechanical properties. However, it is often difficult or impossible to determine the numbers of proteins bound in such experiments, especially when the proteins interact nonspecifically with DNA. In the first project, we developed single-molecule versions of classical thermodynamic Maxwell relations and proposed that these relations could be used to measure DNA-bound protein numbers, changes in DNA double-helix torque with force, and many other quantities which are hard to directly measure. This approach does not need any theoretical assumptions beyond the existence of thermodynamic equilibrium and has been used in single-DNA experiments. Many single-molecule experiments associated with DNA-bending proteins suggest the existence of cooperative interactions between adjacent DNA-bound proteins. In the second project, we studied a statistical-mechanical worm-like chain model including binding cooperativity effects and found that the intrinsic cooperativity of binding sharpens force-extension curves and causes enhancement of fluctuation of extension and protein occupation. This model also allows us to estimate the intrinsic cooperativity in experiments. We also analyzed force-generated cooperativity and found that the related interaction between proteins is always attractive. This suggests that tension in DNA in vivo could alter the distribution of proteins bound along DNA, causing chromosome refolding, or changes in gene expression. In the third project, we investigated the correlations along DNA-protein complexes. We found there are two different correlation lengths corrected to the geometry of DNA bending - the shorter “longitudinal” correlation length ξ∥(
Configuration-constrained cranking Hartree-Fock pairing calculations for sidebands of nuclei
NASA Astrophysics Data System (ADS)
Liang, W. Y.; Jiao, C. F.; Wu, Q.; Fu, X. M.; Xu, F. R.
2015-12-01
Background: Nuclear collective rotations have been successfully described by the cranking Hartree-Fock-Bogoliubov (HFB) model. However, for rotational sidebands which are built on intrinsic excited configurations, it may not be easy to find converged cranking HFB solutions. The nonconservation of the particle number in the BCS pairing is another shortcoming. To improve the pairing treatment, a particle-number-conserving (PNC) pairing method was suggested. But the existing PNC calculations were performed within a phenomenological one-body potential (e.g., Nilsson or Woods-Saxon) in which one has to deal the double-counting problem. Purpose: The present work aims at an improved description of nuclear rotations, particularly for the rotations of excited configurations, i.e., sidebands. Methods: We developed a configuration-constrained cranking Skyrme Hartree-Fock (SHF) calculation with the pairing correlation treated by the PNC method. The PNC pairing takes the philosophy of the shell model which diagonalizes the Hamiltonian in a truncated model space. The cranked deformed SHF basis provides a small but efficient model space for the PNC diagonalization. Results: We have applied the present method to the calculations of collective rotations of hafnium isotopes for both ground-state bands and sidebands, reproducing well experimental observations. The first up-bendings observed in the yrast bands of the hafnium isotopes are reproduced, and the second up-bendings are predicted. Calculations for rotational bands built on broken-pair excited configurations agree well with experimental data. The band-mixing between two Kπ=6+ bands observed in 176Hf and the K purity of the 178Hf rotational state built on the famous 31 yr Kπ=16+ isomer are discussed. Conclusions: The developed configuration-constrained cranking calculation has been proved to be a powerful tool to describe both the yrast bands and sidebands of deformed nuclei. The analyses of rotational moments of inertia help to understand the structures of nuclei, including rotational alignments, configurations, and competitions between collective and single-particle excitations.
Decoupled recovery of energy and momentum with correction of n = 2 error fields
Paz-Soldan, Carlos A.; Logan, Nikolas C.; Lanctot, Matthew J.; ...
2015-07-06
Experiments applying known n = 2 “proxy” error fields (EFs) find that the rotation braking introduced by the proxy EF cannot be completely alleviated through optimal n = 2 correction with poorly matched poloidal spectra. This imperfect performance recovery demonstrates the importance of correcting multiple components of the n = 2 field spectrum and is in contrast to previous results with n = 1 EFs despite similar execution. Measured optimal n = 2 proxy EF correction currents are consistent with those required to null dominant mode coupling to the resonant surfaces and minimize the neoclassical toroidal viscosity (NTV) torque, calculatedmore » using ideal MHD plasma response computation. Unlike rotation braking, density pumpout can be fully corrected despite poorly matched spectra, indicating density pumpout is driven only by a single component proportional to the resonant coupling. Through precise n = 2 spectral control density pumpout and rotation braking can thus be decoupled. Rotation braking with n = 2 fields is also found to be proportional to the level of concurrent toroidal rotation, consistent with NTV theory. Lastly, plasmas with modest countercurrent rotation are insensitive to the n = 2 field with neither rotation braking nor density pumpout observed.« less
TH-A-9A-03: Dosimetric Effect of Rotational Errors for Lung Stereotactic Body Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J; Kim, H; Park, J
2014-06-15
Purpose: To evaluate the dosimetric effects on target volume and organs at risk (OARs) due to roll rotational errors in treatment setup of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: There were a total of 23 volumetric modulated arc therapy (VMAT) plans for lung SBRT examined in this retrospective study. Each CT image of VMAT plans was intentionally rotated by ±1°, ±2°, and ±3° to simulate roll rotational setup errors. The axis of rotation was set at the center of T-spine. The target volume and OARs in the rotated CT images were re-defined by deformable registration of originalmore » contours. The dose distributions on each set of rotated images were re-calculated to cover the planning target volume (PTV) with the prescription dose before and after the couch translational correction. The dose-volumetric changes of PTVs and spinal cords were analyzed. Results: The differences in D95% of PTVs by −3°, −2°, −1°, 1°, 2°, and 3° roll rotations before the couch translational correction were on average −11.3±11.4%, −5.46±7.24%, −1.11±1.38% −3.34±3.97%, −9.64±10.3%, and −16.3±14.7%, respectively. After the couch translational correction, those values were −0.195±0.544%, −0.159±0.391%, −0.188±0.262%, −0.310±0.270%, −0.407±0.331%, and −0.433±0.401%, respectively. The maximum dose difference of spinal cord among the 23 plans even after the couch translational correction was 25.9% at −3° rotation. Conclusions: Roll rotational setup errors in lung SBRT significantly influenced the coverage of target volume using VMAT technique. This could be in part compensated by the translational couch correction. However, in spite of the translational correction, the delivered doses to the spinal cord could be more than the calculated doses. Therefore if rotational setup errors exist during lung SBRT using VMAT technique, the rotational correction would rather be considered to prevent over-irradiation of normal tissues than the translational correction.« less
Geometry, kinematics and tectonic models of the Kazakhstan Orocline, Central Asian Orogenic Belt
NASA Astrophysics Data System (ADS)
Li, Pengfei; Sun, Min; Rosenbaum, Gideon; Yuan, Chao; Safonova, Inna; Cai, Keda; Jiang, Yingde; Zhang, Yunying
2018-03-01
The Central Asian Orogenic Belt (CAOB) is one of the largest accretionary orogens on Earth and is characterized by the occurrence of tight oroclines (Kazakhstan and Tuva-Mongolian oroclines). The origin of these large-scale orogenic curvatures is not quite understood, but is fundamentally important for understanding crustal growth and tectonic evolution of the CAOB. Here we provide an outline of available geological and paleomagnetic data around the Kazakhstan Orocline, with an aim of clarifying the geometry, kinematics and geodynamic origin of the orocline. The Kazakhstan Orocline is evident in a total magmatic image, and can be traced by the continuation of high magnetic anomalies associated with the Devonian Volcanic Belt and the Late Devonian to Carboniferous Balkhash-Yili arc. Paleomagnetic data show ∼112-126° clockwise rotation of the northern limb relative to the southern limb in the Late Devonian to Early Carboniferous, as well as ∼15-28° clockwise rotation of the northern limb and ∼39-40° anticlockwise rotation of the southern limb relative to the hinge of the orocline during the Late Carboniferous to Permian. We argue that the Kazakhstan Orocline experienced two-stage bending with the early stage of bending (Late Devonian to Early Carboniferous; ∼112-126°) driven by slab rollback, and the later stage (Late Carboniferous to Permian; 54-68°) possibly associated with the amalgamation of the Siberian, Tarim and Baltic cratons. This new tectonic model is compatible with the occurrence of rift basins, the spatial migration of magmatic arc, and the development of large-scale strike-slip fault systems during oroclinal bending.
Freeman, Andrew L; Fahim, Mina S; Bechtold, Joan E
2012-10-01
Previous methods of pedicle screw strain measurement have utilized complex, time consuming methods of strain gauge application, experience high failure rates, do not effectively measure resultant bending moments, and cannot predict moment orientation. The purpose of this biomechanical study was to validate an improved method of quantifying pedicle screw bending moment orientation and magnitude. Pedicle screws were instrumented to measure biplanar screw bending moments by positioning four strain gauges on flat, machined surfaces below the screw head. Screws were calibrated to measure bending moments by hanging certified weights a known distance from the strain gauges. Loads were applied in 30 deg increments at 12 different angles while recording data from two independent strain channels. The data were then analyzed to calculate the predicted orientation and magnitude of the resultant bending moment. Finally, flexibility tests were performed on a cadaveric motion segment implanted with the instrumented screws to demonstrate the implementation of this technique. The difference between the applied and calculated orientation of the bending moments averaged (±standard error of the mean (SEM)) 0.3 ± 0.1 deg across the four screws for all rotations and loading conditions. The calculated resultant bending moments deviated from the actual magnitudes by an average of 0.00 ± 0.00 Nm for all loading conditions. During cadaveric testing, the bending moment orientations were medial/lateral in flexion-extension, variable in lateral bending, and diagonal in axial torsion. The technique developed in this study provides an accurate method of calculating the orientation and magnitude of screw bending moments and can be utilized with any pedicle screw fixation system.
NASA Astrophysics Data System (ADS)
Wang, Zhen; Xiao, Longsheng; Wang, Wei; Wu, Chao; Tang, Xiahui
2018-01-01
Owing to their good diffusion cooling and low sensitivity to misalignment, slab-shape negative-branch unstable-waveguide resonators are widely used for high-power lasers in industry. As the output beam of the resonator is astigmatic, an external beam shaping system is required. However, the transverse dimension of the cavity mirrors in the resonator is large. For a long-time operation, the heating of cavity mirrors can be non-uniform. This results in micro-deformation and a change in the radius of curvature of the cavity mirrors, and leads to an output beam of an offset optical axis of the resonator. It was found that a change in the radius of curvature of 0.1% (1 mm) caused by thermal deformation generates a transverse displacement of 1.65 mm at the spatial filter of the external beam shaping system, and an output power loss of more than 80%. This can potentially burn out the spatial filter. In order to analyze the effect of the offset optical axis of the beam on the external optical path, we analyzed the transverse displacement and rotational misalignments of the spatial filter. For instance, if the transverse displacement was 0.3 mm, the loss in the output power was 9.6% and a sidelobe appeared in the unstable direction. If the angle of rotation was 5°, the loss in the output power was 2%, and the poles were in the direction of the waveguide. Based on these results, by adjusting the bending mirror, the deviation angle of the output beam of the resonator cavity was corrected, in order to obtain maximum output power and optimal beam quality. Finally, the propagation characteristics of the corrected output beam were analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, J.; Yu, T.; Papajak, E.
2011-01-01
Many methods for correcting harmonic partition functions for the presence of torsional motions employ some form of one-dimensional torsional treatment to replace the harmonic contribution of a specific normal mode. However, torsions are often strongly coupled to other degrees of freedom, especially other torsions and low-frequency bending motions, and this coupling can make assigning torsions to specific normal modes problematic. Here, we present a new class of methods, called multi-structural (MS) methods, that circumvents the need for such assignments by instead adjusting the harmonic results by torsional correction factors that are determined using internal coordinates. We present three versions ofmore » the MS method: (i) MS-AS based on including all structures (AS), i.e., all conformers generated by internal rotations; (ii) MS-ASCB based on all structures augmented with explicit conformational barrier (CB) information, i.e., including explicit calculations of all barrier heights for internal-rotation barriers between the conformers; and (iii) MS-RS based on including all conformers generated from a reference structure (RS) by independent torsions. In the MS-AS scheme, one has two options for obtaining the local periodicity parameters, one based on consideration of the nearly separable limit and one based on strongly coupled torsions. The latter involves assigning the local periodicities on the basis of Voronoi volumes. The methods are illustrated with calculations for ethanol, 1-butanol, and 1-pentyl radical as well as two one-dimensional torsional potentials. The MS-AS method is particularly interesting because it does not require any information about conformational barriers or about the paths that connect the various structures.« less
Zheng, Jingjing; Yu, Tao; Papajak, Ewa; Alecu, I M; Mielke, Steven L; Truhlar, Donald G
2011-06-21
Many methods for correcting harmonic partition functions for the presence of torsional motions employ some form of one-dimensional torsional treatment to replace the harmonic contribution of a specific normal mode. However, torsions are often strongly coupled to other degrees of freedom, especially other torsions and low-frequency bending motions, and this coupling can make assigning torsions to specific normal modes problematic. Here, we present a new class of methods, called multi-structural (MS) methods, that circumvents the need for such assignments by instead adjusting the harmonic results by torsional correction factors that are determined using internal coordinates. We present three versions of the MS method: (i) MS-AS based on including all structures (AS), i.e., all conformers generated by internal rotations; (ii) MS-ASCB based on all structures augmented with explicit conformational barrier (CB) information, i.e., including explicit calculations of all barrier heights for internal-rotation barriers between the conformers; and (iii) MS-RS based on including all conformers generated from a reference structure (RS) by independent torsions. In the MS-AS scheme, one has two options for obtaining the local periodicity parameters, one based on consideration of the nearly separable limit and one based on strongly coupled torsions. The latter involves assigning the local periodicities on the basis of Voronoi volumes. The methods are illustrated with calculations for ethanol, 1-butanol, and 1-pentyl radical as well as two one-dimensional torsional potentials. The MS-AS method is particularly interesting because it does not require any information about conformational barriers or about the paths that connect the various structures.
Sawicki, Richard H.; Sweatt, William
1987-01-01
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique utilizes first means which defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and second means acting on the first means for adjustably bending the light reflecting surface into a particular selected one of the different curvatures depending upon the astigmatism to be corrected for and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment to the reinforced side edges of the light reflecting surface.
Holewijn, Roderick M.; de Kleuver, Marinus; van der Veen, Albert J.; Emanuel, Kaj S.; Bisschop, Arno; Stadhouder, Agnita; van Royen, Barend J.
2017-01-01
Study Design: Biomechanical study. Objective: Recently, a posterior concave periapical distraction device for fusionless scoliosis correction was introduced. The goal of this study was to quantify the effect of the periapical distraction device on spinal range of motion (ROM) in comparison with traditional rigid pedicle screw-rod instrumentation. Methods: Using a spinal motion simulator, 6 human spines were loaded with 4 N m and 6 porcine spines with 2 N m to induce flexion-extension (FE), lateral bending (LB), and axial rotation (AR). ROM was measured in 3 conditions: untreated, periapical distraction device, and rigid pedicle screw-rod instrumentation. Results: The periapical distraction device caused a significant (P < .05) decrease in ROM of FE (human, −40.0% and porcine, −55.9%) and LB (human, −18.2% and porcine, −17.9%) as compared to the untreated spine, while ROM of AR remained unaffected. In comparison, rigid instrumentation caused a significantly (P < .05) larger decrease in ROM of FE (human, −80.9% and porcine, −94.0%), LB (human, −75.0% and porcine, −92.2%), and AR (human, −71.3% and porcine, −86.9%). Conclusions: Although no destructive forces were applied, no device failures were observed. Spinal ROM was significantly less constrained by the periapical distraction device compared to rigid pedicle screw-rod instrumentation. Therefore, provided that scoliosis correction is achieved, a more physiological spinal motion is expected after scoliosis correction with the posterior concave periapical distraction device. PMID:28811983
Gravitropism in Leafy Dicot Stems
NASA Technical Reports Server (NTRS)
Salisbury, F. B.
1985-01-01
A polarizing research microscope with rotating stage and associated camera equipment were ordered, and techniques of fixation and preparation of specimens were perfected for studying possible changes in orientation of cellulose microfibrils in cell walls of gravistimulated dicot stems. Acid ethephon solutions or acid without ethephon caused elongation of stem tissues where they were applied; stems bent away from the side of application. Acid solutions applied to the bottom of horizontal stems greatly delayed bending. Research in tissue sensitivity changes during gravitropic bending of soybean hypocotyls while immersed in auxin and in castor bean stems is also reported.
Induction of optical vortex in the crystals subjected to bending stresses.
Skab, Ihor; Vasylkiv, Yurij; Vlokh, Rostyslav
2012-08-20
We describe a method for generation of optical vortices that relies on bending of transparent parallelepiped-shaped samples fabricated from either glass or crystalline solid materials. It is shown that the induced singularity of optical indicatrix rotation leads in general to appearance of a mixed screw-edge dislocation of the phase front of outgoing optical beam. At the same time, some specified geometrical parameters of the sample can ensure generation of a purely screw dislocation of the phase front and, as a result, a singly charged canonical optical vortex.
Electrothermally-Actuated Micromirrors with Bimorph Actuators--Bending-Type and Torsion-Type.
Tsai, Cheng-Hua; Tsai, Chun-Wei; Chang, Hsu-Tang; Liu, Shih-Hsiang; Tsai, Jui-Che
2015-06-22
Three different electrothermally-actuated MEMS micromirrors with Cr/Au-Si bimorph actuators are proposed. The devices are fabricated with the SOIMUMPs process developed by MEMSCAP, Inc. (Durham, NC, USA). A silicon-on-insulator MEMS process has been employed for the fabrication of these micromirrors. Electrothermal actuation has achieved a large angular movement in the micromirrors. Application of an external electric current 0.04 A to the bending-type, restricted-torsion-type, and free-torsion-type mirrors achieved rotation angles of 1.69°, 3.28°, and 3.64°, respectively.
Absolute plate motion of Africa around Hawaii-Emperor bend time
NASA Astrophysics Data System (ADS)
Maher, S. M.; Wessel, P.; Müller, R. D.; Williams, S. E.; Harada, Y.
2015-06-01
Numerous regional plate reorganizations and the coeval ages of the Hawaiian Emperor bend (HEB) and Louisville bend of 50-47 Ma have been interpreted as a possible global tectonic plate reorganization at ˜chron 21 (47.9 Ma). Yet for a truly global event we would expect a contemporaneous change in Africa absolute plate motion (APM) reflected by physical evidence distributed on the Africa Plate. This evidence has been postulated to take the form of the Réunion-Mascarene bend which exhibits many HEB-like features, such as a large angular change close to ˜chron 21. However, the Réunion hotspot trail has recently been interpreted as a sequence of continental fragments with incidental hotspot volcanism. Here we show that the alternative Réunion-Mascarene Plateau trail can also satisfy the age progressions and geometry of other hotspot trails on the Africa Plate. The implied motion, suggesting a pivoting of Africa from 67 to 50 Ma, could explain the apparent bifurcation of the Tristan hotspot chain, the age reversals seen along the Walvis Ridge, the sharp curve of the Canary trail, and the diffuse nature of the St. Helena chain. To test this hypothesis further we made a new Africa APM model that extends back to ˜80 Ma using a modified version of the Hybrid Polygonal Finite Rotation Method. This method uses seamount chains and their associated hotspots as geometric constraints for the model, and seamount age dates to determine APM through time. While this model successfully explains many of the volcanic features, it implies an unrealistically fast global lithospheric net rotation, as well as improbable APM trajectories for many other plates, including the Americas, Eurasia and Australia. We contrast this speculative model with a more conventional model in which the Mascarene Plateau is excluded in favour of the Chagos-Laccadive Ridge rotated into the Africa reference frame. This second model implies more realistic net lithospheric rotation and far-field APMs, but fails to explain key details of the Atlantic Ocean volcanic chains. Both models predict a Canary plume influence beneath the Madeiras. Neither model, when projected via the global plate circuit into the Pacific, predicts any significant change in plate motion around chron 21. Consequently, Africa APM models do not appear to provide independent support for a chron 21 global reorganization.
NASA Astrophysics Data System (ADS)
Dymnikova, I. G.
1986-03-01
A study is made of the trajectories of free motion of test particles and photons in the Kerr metric, which describes the gravitational field of a rotating massive body. The trajectories are classified on the basis of the integrals of the motion, which have a clear physical meaning. The cases of a strong gravitational field in the neighborhood of a rotating black hole as well as the weak-field approximation describing the motion of particles in the gravitational field of a rotating star or galaxy are considered. The review includes bound states (orbits) in the field of a rotating mass, scattering and gravitational capture of particles and photons by a rotating black hole, trajectories of falling into a black hole, and the bending of light rays and the gravitational time delay of signals in the gravitational field of a rotating body.
Bertholet, Jenny; Worm, Esben; Høyer, Morten; Poulsen, Per
2017-06-01
Accurate patient positioning is crucial in stereotactic body radiation therapy (SBRT) due to a high dose regimen. Cone-beam computed tomography (CBCT) is often used for patient positioning based on radio-opaque markers. We compared six CBCT-based set-up strategies with or without rotational correction. Twenty-nine patients with three implanted markers received 3-6 fraction liver SBRT. The markers were delineated on the mid-ventilation phase of a 4D-planning-CT. One pretreatment CBCT was acquired per fraction. Set-up strategy 1 used only translational correction based on manual marker match between the CBCT and planning CT. Set-up strategy 2 used automatic 6 degrees-of-freedom registration of the vertebrae closest to the target. The 3D marker trajectories were also extracted from the projections and the mean position of each marker was calculated and used for set-up strategies 3-6. Translational correction only was used for strategy 3. Translational and rotational corrections were used for strategies 4-6 with the rotation being either vertebrae based (strategy 4), or marker based and constrained to ±3° (strategy 5) or unconstrained (strategy 6). The resulting set-up error was calculated as the 3D root-mean-square set-up error of the three markers. The set-up error of the spinal cord was calculated for all strategies. The bony anatomy set-up (2) had the largest set-up error (5.8 mm). The marker-based set-up with unconstrained rotations (6) had the smallest set-up error (0.8 mm) but the largest spinal cord set-up error (12.1 mm). The marker-based set-up with translational correction only (3) or with bony anatomy rotational correction (4) had equivalent set-up error (1.3 mm) but rotational correction reduced the spinal cord set-up error from 4.1 mm to 3.5 mm. Marker-based set-up was substantially better than bony-anatomy set-up. Rotational correction may improve the set-up, but further investigations are required to determine the optimal correction strategy.
Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study
Kiapour, Ali; Yerby, Scott A.; Goel, Vijay K.
2015-01-01
Background Adjacent segment disease is a recognized consequence of fusion in the spinal column. Fusion of the sacroiliac joint is an effective method of pain reduction. Although effective, the consequences of sacroiliac joint fusion and the potential for adjacent segment disease for the adjacent lumbar spinal levels is unknown. The objective of this study was to quantify the change in range of motion of the sacroiliac joint and the adjacent lumbar spinal motion segments due to sacroiliac joint fusion and compare these changes to previous literature to assess the potential for adjacent segment disease in the lumbar spine. Methods An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the sacroiliac joint using three laterally placed triangular implants (iFuse Implant System, SI-BONE, Inc., San Jose, CA). The range of motion of the sacroiliac joint and the adjacent lumbar spinal motion segments were calculated using a hybrid loading protocol and compared with the intact range of motion in flexion, extension, lateral bending, and axial rotation. Results The range of motions of the treated sacroiliac joints were reduced in flexion, extension, lateral bending, and axial rotation, by 56.6%, 59.5%, 27.8%, and 53.3%, respectively when compared with the intact condition. The stiffening of the sacroiliac joint resulted in increases at the adjacent lumbar motion segment (L5-S1) for flexion, extension, lateral bending, and axial rotation, of 3.0%, 3.7%, 1.1%, and 4.6%, respectively. Conclusions Fusion of the sacroiliac joint resulted in substantial (> 50%) reductions in flexion, extension, and axial rotation of the sacroiliac joint with minimal (< 5%) increases in range of motion in the lumbar spine. Although the predicted increases in lumbar range of motion are minimal after sacroiliac joint fusion, the long-term clinical results remain to be investigated. PMID:26767156
Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study.
Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K
2015-01-01
Adjacent segment disease is a recognized consequence of fusion in the spinal column. Fusion of the sacroiliac joint is an effective method of pain reduction. Although effective, the consequences of sacroiliac joint fusion and the potential for adjacent segment disease for the adjacent lumbar spinal levels is unknown. The objective of this study was to quantify the change in range of motion of the sacroiliac joint and the adjacent lumbar spinal motion segments due to sacroiliac joint fusion and compare these changes to previous literature to assess the potential for adjacent segment disease in the lumbar spine. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the sacroiliac joint using three laterally placed triangular implants (iFuse Implant System, SI-BONE, Inc., San Jose, CA). The range of motion of the sacroiliac joint and the adjacent lumbar spinal motion segments were calculated using a hybrid loading protocol and compared with the intact range of motion in flexion, extension, lateral bending, and axial rotation. The range of motions of the treated sacroiliac joints were reduced in flexion, extension, lateral bending, and axial rotation, by 56.6%, 59.5%, 27.8%, and 53.3%, respectively when compared with the intact condition. The stiffening of the sacroiliac joint resulted in increases at the adjacent lumbar motion segment (L5-S1) for flexion, extension, lateral bending, and axial rotation, of 3.0%, 3.7%, 1.1%, and 4.6%, respectively. Fusion of the sacroiliac joint resulted in substantial (> 50%) reductions in flexion, extension, and axial rotation of the sacroiliac joint with minimal (< 5%) increases in range of motion in the lumbar spine. Although the predicted increases in lumbar range of motion are minimal after sacroiliac joint fusion, the long-term clinical results remain to be investigated.
Reliability approach to rotating-component design. [fatigue life and stress concentration
NASA Technical Reports Server (NTRS)
Kececioglu, D. B.; Lalli, V. R.
1975-01-01
A probabilistic methodology for designing rotating mechanical components using reliability to relate stress to strength is explained. The experimental test machines and data obtained for steel to verify this methodology are described. A sample mechanical rotating component design problem is solved by comparing a deterministic design method with the new design-by reliability approach. The new method shows that a smaller size and weight can be obtained for specified rotating shaft life and reliability, and uses the statistical distortion-energy theory with statistical fatigue diagrams for optimum shaft design. Statistical methods are presented for (1) determining strength distributions for steel experimentally, (2) determining a failure theory for stress variations in a rotating shaft subjected to reversed bending and steady torque, and (3) relating strength to stress by reliability.
Temperature corrections for mechanically graded lumber
David W. Green; James W. Evans; James D. Logan; Jim Allen
1999-01-01
The continuous lumber tester (CLT) is the most widely used grading machine in the world. With the CLT, the flatwise bending stiffness of lumber is measured as it passes through the machine. The modulus of elasticity (MOE) is calculated from the force required to bend the lumber to a fixed deflection of 7.94 mm (5/16 in.), and this MOE is used in assigning a machine...
Kim, M-J; Park, J H; Kojima, Y; Tai, K; Chae, J-M
2018-02-01
To estimate the optimal bending angles in the running loop for mesial translation of a mandibular second molar using indirect skeletal anchorage and to clarify the mechanics of tipping and rotating the molar. A three-dimensional finite element model was developed for predicting tooth movement, and a mechanical model based on the beam theory was constructed for clarifying the force systems. When using a running loop without bends, the molar tipped mesially 14.4° and lingually 0.6°, rotated counterclockwise 4.1°, and the incisors retracted 0.02 mm and intruded 0.05 mm. These angles were about the same as those estimated by the beam theory. When the amount of tip back and toe-in angles was 11.0°, mesial translation of the molar was achieved, and incisors retracted 0.10 mm and intruded 0.30 mm. Mesial translation of a mandibular second molar without any significant movement of anterior teeth was achieved during protraction by controlling the tip back and toe-in angles and enhancing anterior anchorage with the combined use of a running loop and indirect skeletal anchorage. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Oroclines and paleomagnetism in Borneo and South-East Asia
NASA Astrophysics Data System (ADS)
Hutchison, Charles S.
2010-12-01
Oroclinal bending of Borneo is interpreted to result from indentation and collision by the continental promontory of the Miri Zone-Central Luconia Province of northern Sundaland into southern Sundaland. The collision caused strong compression and uplift of the intervening Sibu Zone Upper Cretaceous-Eocene Rajang-Embaluh Group turbidite basin that was floored by oceanic crust of the Proto South China Sea. Timing of the collision is indicated by uplift of turbidite formations to be overlain by Upper Eocene-Lower Oligocene carbonates and intrusion of tin-mineralised granites into the turbidites at the south-east maximum inflexion of the orocline, a region complicated by juxtaposition of both shallow and deep water formations. The oroclinal model, requiring clockwise rotation of the north-west limb, is given no support from the paleomagnetic data that instead demonstrate about 50° of Cenozoic anti-clockwise rotation. Unfortunately not a single outcrop of the strongly oroclinally bent Sibu Zone rocks was measured for paleomagnetism in the north-west limb. Limited support was given for the required anti-clockwise rotation in the north-east limb. Previous syntheses emphasised anti-clockwise rotation, or stable non-rotation of the greater Borneo region as a coherent entity, without any internal deformation. Such models have ignored the oroclinal shape defined by the areal geology of the island, known since early Dutch publications. The northern Thailand-Myanmar north-south-trending geology fabric results from indentation by a promontory of continental India at the Assam-Yunnan oroclinal syntaxis, resulting in paleomagnetically-determined clockwise rotation. The bend of Peninsular Malaysia and Sumatra, from north-south changing to west-east towards Borneo in the south, remains difficult to model because of widespread remagnetisation.
Wang, Xiaoling; Meng, Shuo; Han, Jingshi
2017-10-03
The Bacterial flagellar filament can undergo a polymorphic phase transition in response to both mechanical and chemical variations in vitro and in vivo environments. Under mechanical stimuli, such as viscous flow or forces induced by motor rotation, the filament changes its phase from left-handed normal (N) to right-handed semi-coiled (SC) via phase nucleation and growth. Our detailed mechanical analysis of existing experiments shows that both torque and bending moment contribute to the filament phase transition. In this paper, we establish a non-convex and non-local continuum model based on the Ginzburg-Landau theory to describe main characteristics of the filament phase transition such as new-phase nucleation, growth, propagation and the merging of neighboring interfaces. The finite element method (FEM) is adopted to simulate the phase transition under a displacement-controlled loading condition (rotation angle and bending deflection). We show that new-phase nucleation corresponds to the maximum torque and bending moment at the stuck end of the filament. The hysteresis loop in the loading and unloading curves indicates energy dissipation. When the new phase grows and propagates, torque and bending moment remain static. We also find that there is a drop in load when the two interfaces merge, indicating a concomitant reduction in the interfacial energy. Finally, the interface thickness is governed by the coefficients of the gradient of order parameters in the non-local interface energy. Our continuum theory and the finite element method provide a method to study the mechanical behavior of such biomaterials. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de; Department of Medical Physics, German Cancer Research Center, Heidelberg; Giske, Kristina
Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived frommore » a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.« less
Yu, Xiaobo; Yang, Qinghua; Jiang, Haiyue; Pan, Bo; Zhao, Yanyong; Lin, Lin
2017-11-01
Cryptotia is a common congenital ear deformity in Asian populations. In cryptotia, a portion of the upper ear is hidden and fixed in a pocket of the skin of the mastoid. Here we describe our method for cryptotia correction by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. We developed a new method for correcting cryptotia by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. Following ear release, the full-thickness skin rotation flap is rotated into the defect, and the donor site is covered with an ultra-delicate split-thickness skin graft raised in continuity with the flap. All patients exhibited satisfactory release of cryptotia. No cases involved partial or total flap necrosis, and post-operative outcomes using this new technique for cryptotia correction have been more than satisfactory. Our method of using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap to correct cryptotia is simple and reliable. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Takahata, Masahiko; Sudo, Hideki; Hojo, Yoshihiro; Minami, Akio
2010-03-01
The authors present a new posterior correction technique consisting of simultaneous double-rod rotation using 2 contoured rods and polyaxial pedicle screws with or without Nesplon tapes. The purpose of this study is to introduce the basic principles and surgical procedures of this new posterior surgery for correction of adolescent idiopathic scoliosis. Through gradual rotation of the concave-side rod by 2 rod holders, the convex-side rod simultaneously rotates with the the concave-side rod. This procedure does not involve any force pushing down the spinal column around the apex. Since this procedure consists of upward pushing and lateral translation of the spinal column with simultaneous double-rod rotation maneuvers, it is simple and can obtain thoracic kyphosis as well as favorable scoliosis correction. This technique is applicable not only to a thoracic single curve but also to double major curves in cases of adolescent idiopathic scoliosis.
General relativistic radiative transfer code in rotating black hole space-time: ARTIST
NASA Astrophysics Data System (ADS)
Takahashi, Rohta; Umemura, Masayuki
2017-02-01
We present a general relativistic radiative transfer code, ARTIST (Authentic Radiative Transfer In Space-Time), that is a perfectly causal scheme to pursue the propagation of radiation with absorption and scattering around a Kerr black hole. The code explicitly solves the invariant radiation intensity along null geodesics in the Kerr-Schild coordinates, and therefore properly includes light bending, Doppler boosting, frame dragging, and gravitational redshifts. The notable aspect of ARTIST is that it conserves the radiative energy with high accuracy, and is not subject to the numerical diffusion, since the transfer is solved on long characteristics along null geodesics. We first solve the wavefront propagation around a Kerr black hole that was originally explored by Hanni. This demonstrates repeated wavefront collisions, light bending, and causal propagation of radiation with the speed of light. We show that the decay rate of the total energy of wavefronts near a black hole is determined solely by the black hole spin in late phases, in agreement with analytic expectations. As a result, the ARTIST turns out to correctly solve the general relativistic radiation fields until late phases as t ˜ 90 M. We also explore the effects of absorption and scattering, and apply this code for a photon wall problem and an orbiting hotspot problem. All the simulations in this study are performed in the equatorial plane around a Kerr black hole. The ARTIST is the first step to realize the general relativistic radiation hydrodynamics.
Optimised in vitro applicable loads for the simulation of lateral bending in the lumbar spine.
Dreischarf, Marcel; Rohlmann, Antonius; Bergmann, Georg; Zander, Thomas
2012-07-01
In in vitro studies of the lumbar spine simplified loading modes (compressive follower force, pure moment) are usually employed to simulate the standard load cases flexion-extension, axial rotation and lateral bending of the upper body. However, the magnitudes of these loads vary widely in the literature. Thus the results of current studies may lead to unrealistic values and are hardly comparable. It is still unknown which load magnitudes lead to a realistic simulation of maximum lateral bending. A validated finite element model of the lumbar spine was used in an optimisation study to determine which magnitudes of the compressive follower force and bending moment deliver results that fit best with averaged in vivo data. The best agreement with averaged in vivo measured data was found for a compressive follower force of 700 N and a lateral bending moment of 7.8 Nm. These results show that loading modes that differ strongly from the optimised one may not realistically simulate maximum lateral bending. The simplified but in vitro applicable loading cannot perfectly mimic the in vivo situation. However, the optimised magnitudes are those which agree best with averaged in vivo measured data. Its consequent application would lead to a better comparability of different investigations. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Hodges, D. H., Roberta.
1976-01-01
The stability of elastic flap bending, lead-lag bending, and torsion of uniform, untwisted, cantilever rotor blades without chordwise offsets between the elastic, mass, tension, and areodynamic center axes is investigated for the hovering flight condition. The equations of motion are obtained by simplifying the general, nonlinear, partial differential equations of motion of an elastic rotating cantilever blade. The equations are adapted for a linearized stability analysis in the hovering flight condition by prescribing aerodynamic forces, applying Galerkin's method, and linearizing the resulting ordinary differential equations about the equilibrium operating condition. The aerodynamic forces are obtained from strip theory based on a quasi-steady approximation of two-dimensional unsteady airfoil theory. Six coupled mode shapes, calculated from free vibration about the equilibrium operating condition, are used in the linearized stability analysis. The study emphasizes the effects of two types of structural coupling that strongly influence the stability of hingeless rotor blades. The first structural coupling is the linear coupling between flap and lead-lag bending of the rotor blade. The second structural coupling is a nonlinear coupling between flap bending, lead-lag bending, and torsion deflections. Results are obtained for a wide variety of hingeless rotor configurations and operating conditions in order to provide a reasonably complete picture of hingeless rotor blade stability characteristics.
Properties of Vector Preisach Models
NASA Technical Reports Server (NTRS)
Kahler, Gary R.; Patel, Umesh D.; Torre, Edward Della
2004-01-01
This paper discusses rotational anisotropy and rotational accommodation of magnetic particle tape. These effects have a performance impact during the reading and writing of the recording process. We introduce the reduced vector model as the basis for the computations. Rotational magnetization models must accurately compute the anisotropic characteristics of ellipsoidally magnetizable media. An ellipticity factor is derived for these media that computes the two-dimensional magnetization trajectory for all applied fields. An orientation correction must be applied to the computed rotational magnetization. For isotropic materials, an orientation correction has been developed and presented. For anisotropic materials, an orientation correction is introduced.
A Higher-Order Bending Theory for Laminated Composite and Sandwich Beams
NASA Technical Reports Server (NTRS)
Cook, Geoffrey M.
1997-01-01
A higher-order bending theory is derived for laminated composite and sandwich beams. This is accomplished by assuming a special form for the axial and transverse displacement expansions. An independent expansion is also assumed for the transverse normal stress. Appropriate shear correction factors based on energy considerations are used to adjust the shear stiffness. A set of transverse normal correction factors is introduced, leading to significant improvements in the transverse normal strain and stress for laminated composite and sandwich beams. A closed-form solution to the cylindrical elasticity solutions for a wide range of beam aspect ratios and commonly used material systems. Accurate shear stresses for a wide range of laminates, including the challenging unsymmetric composite and sandwich laminates, are obtained using an original corrected integration scheme. For application of the theory to a wider range of problems, guidelines for finite element approximations are presented.
NASA Astrophysics Data System (ADS)
Tseng, Chien-Hsun
2018-06-01
This paper aims to develop a multidimensional wave digital filtering network for predicting static and dynamic behaviors of composite laminate based on the FSDT. The resultant network is, thus, an integrated platform that can perform not only the free vibration but also the bending deflection of moderate thick symmetric laminated plates with low plate side-to-thickness ratios (< = 20). Safeguarded by the Courant-Friedrichs-Levy stability condition with the least restriction in terms of optimization technique, the present method offers numerically high accuracy, stability and efficiency to proceed a wide range of modulus ratios for the FSDT laminated plates. Instead of using a constant shear correction factor (SCF) with a limited numerical accuracy for the bending deflection, an optimum SCF is particularly sought by looking for a minimum ratio of change in the transverse shear energy. This way, it can predict as good results in terms of accuracy for certain cases of bending deflection. Extensive simulation results carried out for the prediction of maximum bending deflection have demonstratively proven that the present method outperforms those based on the higher-order shear deformation and layerwise plate theories. To the best of our knowledge, this is the first work that shows an optimal selection of SCF can significantly increase the accuracy of FSDT-based laminates especially compared to the higher order theory disclaiming any correction. The highest accuracy of overall solution is compared to the 3D elasticity equilibrium one.
Fracture characteristics, microstructure, and tissue reaction of Ti-5Al-2.5Fe for orthopedic surgery
NASA Astrophysics Data System (ADS)
Niinomi, Mitsuo; Kobayashi, Toshiro; Toriyama, Osamu; Kawakami, Noriaki; Ishida, Yoshihito; Matsuyama, Yukihiro
1996-12-01
The microstructure of Ti-5Al-2.5Fe, which is expected to be used widely as an implant material not only for artificial hip joints but also for instrumentations of scoliosis surgery, was variously changed by heat treatments. The effect of the microstructure on mechanical properties, fracture toughness, and rotating-bending fatigue strength in the air and simulated body environment, that is, Ringer’s solution, was then investigated. Furthermore, the effect of the living body environment on mechanical properties and fracture toughness in Ti-5Al-2.5Fe were investigated on the specimens implanted into rabbit for about 11 months. The data of Ti-5Al-2.5Fe were compared with those of Ti-6Al-4V ELI, which has been used as an implant material mainly for artificial hip joints, and SUS 316L, which has been used as an implant material for many parts, including the instrumentation of scoliosis surgery. The equiaxed α structure, which is formed by annealing at a temperature below β transus, gives the best balance of strength and ductility in Ti-5Al-2.5Fe. The coarse Widmanstätten α structure, which is formed by solutionizing over β transus followed by air cooling and aging, gives the greatest fracture toughness in Ti-5Al-2.5Fe. This trend is similar to that reported in Ti-6Al-4V ELI. The rotating-bending fatigue strength is the greatest in the equiaxed α structure, which is formed by solutionizing below β transus followed by air cooling and aging in Ti-5Al-2.5Fe. Ti-5Al-2.5Fe exhibits much greater rotating-bending fatigue strength compared with SUS 316L, and equivalent rotating-bending fatigue strength to that of Ti-6Al-4V ELI in both the air and simulated body environments. The rotating-bending fatigue strength of SUS 316L is degraded in the simulated body environment. The corrosion fatigue, therefore, occurs in SUS 316L in the simulated body environment. Fatigue strength of Ti-5Al-2.5Fe in the simulated body environment is degraded by lowering oxygen content in the simulated body environment because the formability of oxide on the specimen surface is considered to be lowered comparing with that in air. The mechanical property and fracture toughness of Ti-5Al-2.5Fe and Ti-6Al-4V ELI are not changed in the living body environment. The hard-surface corrosion layer is, however, formed on the surface of SUS 316L in the living body environment. The C1 peak is detected from the hard-surface corrosion layer by energy-dispersive X-ray (EDX) analysis. These facts suggests a possibility for corrosion fatigue to occur in the living body environment when SUS 316L is used. The fibrous connective tissue and new bone formation are formed beside all metals. There is, however, no big difference between tissue morphology around each implant material.
Asraf, Sagie; Sintov, Yoav; Zalevsky, Zeev
2017-08-07
We propose a novel configuration for an improved and compact all fiber Faraday rotator based on phase matching between the Faraday rotation and bend-induced birefringence. The device utilizes a coiled fiber within two electro-magnetic toroids, such that the fiber length required for getting the beat length is quite long and several rounds of fiber are needed. Analysis of the capabilities of the proposed device and its sensitivity to different parameters is presented. Faraday rotation of 13° was experimentally measured in six meters of single mode silica fiber, with a magnetic field of about 0.06T at a wavelength of 1064nm. We show that phase matching between the two phenomena significantly improves the polarization rotation by a factor of 4-10. In addition, we demonstrate the ability to achieve higher rotation by using Fabry Perot resonator in low terbium doped glass.
Application of fracture toughness scaling models to the ductile-to- brittle transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Link, R.E.; Joyce, J.A.
1996-01-01
An experimental investigation of fracture toughness in the ductile-brittle transition range was conducted. A large number of ASTM A533, Grade B steel, bend and tension specimens with varying crack lengths were tested throughout the transition region. Cleavage fracture toughness scaling models were utilized to correct the data for the loss of constraint in short crack specimens and tension geometries. The toughness scaling models were effective in reducing the scatter in the data, but tended to over-correct the results for the short crack bend specimens. A proposed ASTM Test Practice for Fracture Toughness in the Transition Range, which employs a mastermore » curve concept, was applied to the results. The proposed master curve over predicted the fracture toughness in the mid-transition and a modified master curve was developed that more accurately modeled the transition behavior of the material. Finally, the modified master curve and the fracture toughness scaling models were combined to predict the as-measured fracture toughness of the short crack bend and the tension specimens. It was shown that when the scaling models over correct the data for loss of constraint, they can also lead to non-conservative estimates of the increase in toughness for low constraint geometries.« less
Daniels, Alan H; Paller, David J; Koruprolu, Sarath; McDonnell, Matthew; Palumbo, Mark A; Crisco, Joseph J
2013-01-01
Study Design Biomechanical cadaver investigation Objective To examine dynamic bending stiffness and energy absorption of the lumbar spine with and without implanted Total Disc Replacement (TDR) under simulated physiologic motion. Summary of background data The pendulum testing system is capable of applying physiologic compressive loads without constraining motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. Methods Five unembalmed, frozen human lumbar FSUs were tested on the pendulum system with axial compressive loads of 181N, 282N, 385N, and 488N before and after Synthes ProDisc-L TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5° resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. Results In flexion/extension, the TDR constructs reached equilibrium with significantly (p<0.05) fewer cycles than the intact FSU with compressive loads of 282N, 385N and 488N. Mean dynamic bending stiffness in flexion, extension, and lateral bending increased significantly with increasing load for both the intact FSU and TDR constructs (p<0.001). In flexion, with increasing compressive loading from 181N to 488N, the bending stiffness of the intact FSUs increased from 4.0N-m/° to 5.5N-m/°, compared to 2.1N-m/° to 3.6N-m/° after TDR implantation. At each compressive load, the intact FSU was significantly more stiff than the TDR (p<0.05). Conclusion Lumbar FSUs with implanted TDR were found to be less stiff, but also absorbed more energy during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices are not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions. PMID:22869057
Axial Plane Deformity of the Shoulder in Adolescent Idiopathic Scoliosis.
Menon, Venugopal K; Tahasildar, Naveen; Pillay, Haroon M; M, Anbuselvam
2017-05-01
Prospective observational study. To study axial plane deformation of the shoulder in adolescent idiopathic scoliosis (AIS) and try to correlate it with curve type and surgical correction. It is established that AIS is a 3-dimensional deformity. The rib hump is the most common manifestation of axial plane deformations; the least common manifestation seems to be upper trunk and shoulder rotation, which has been hitherto undescribed. Fourteen consecutive, operated cases of AIS were analyzed prospectively. Preoperative and postoperative x-rays of the spine and clinical photographs were studied. Clinical photographs (top view) were taken with patients in the sitting position, to show shoulder level in relation to the axis of the head and pelvis. Chest computed tomography scans were also studied to determine the direction of apical vertebra and trunk torsion. All 14 patients in this series had their right shoulders anteriorly rotated preoperatively (anticlockwise). The direction of rotation seemed unrelated to the curve type and shoulder elevation, although most had rib humps on the right. This shoulder rotation was corrected postoperatively by routine maneuvers done for scoliosis correction. Minor residual rotation was seen in 6 patients who also had minimal persisting rib hump. In 1 case the axial plane rotation worsened, although the shoulder level and trunk symmetry improved significantly. The apical vertebral rotation on computed tomography had little bearing on the direction of shoulder rotation. Axial plane rotation of the shoulder is a hitherto un-described dimension of AIS deformity complex. Much of it corrects spontaneously with correction of the thoracic spinal deformity.
Hanging-wall deformation above a normal fault: sequential limit analyses
NASA Astrophysics Data System (ADS)
Yuan, Xiaoping; Leroy, Yves M.; Maillot, Bertrand
2015-04-01
The deformation in the hanging wall above a segmented normal fault is analysed with the sequential limit analysis (SLA). The method combines some predictions on the dip and position of the active fault and axial surface, with geometrical evolution à la Suppe (Groshong, 1989). Two problems are considered. The first followed the prototype proposed by Patton (2005) with a pre-defined convex, segmented fault. The orientation of the upper segment of the normal fault is an unknown in the second problem. The loading in both problems consists of the retreat of the back wall and the sedimentation. This sedimentation starts from the lowest point of the topography and acts at the rate rs relative to the wall retreat rate. For the first problem, the normal fault either has a zero friction or a friction value set to 25o or 30o to fit the experimental results (Patton, 2005). In the zero friction case, a hanging wall anticline develops much like in the experiments. In the 25o friction case, slip on the upper segment is accompanied by rotation of the axial plane producing a broad shear zone rooted at the fault bend. The same observation is made in the 30o case, but without slip on the upper segment. Experimental outcomes show a behaviour in between these two latter cases. For the second problem, mechanics predicts a concave fault bend with an upper segment dip decreasing during extension. The axial surface rooting at the normal fault bend sees its dips increasing during extension resulting in a curved roll-over. Softening on the normal fault leads to a stepwise rotation responsible for strain partitioning into small blocks in the hanging wall. The rotation is due to the subsidence of the topography above the hanging wall. Sedimentation in the lowest region thus reduces the rotations. Note that these rotations predicted by mechanics are not accounted for in most geometrical approaches (Xiao and Suppe, 1992) and are observed in sand box experiments (Egholm et al., 2007, referring to Dahl, 1987). References: Egholm, D. L., M. Sandiford, O. R. Clausen, and S. B. Nielsen (2007), A new strategy for discrete element numerical models: 2. sandbox applications, Journal of Geophysical Research, 112 (B05204), doi:10.1029/2006JB004558. Groshong, R. H. (1989), Half-graben structures: Balanced models of extensional fault-bend folds, Geological Society of America Bulletin, 101 (1), 96-105. Patton, T. L. (2005), Sandbox models of downward-steepening normal faults, AAPG Bulletin, 89 (6), 781-797. Xiao, H.-B., and J. Suppe (1992), Orgin of rollover, AAPG Bulletin, 76 (4), 509-529.
Biomechanical testing of a PEEK-based dynamic instrumentation device in a lumbar spine model.
Herren, Christian; Beckmann, Agnes; Meyer, Sabine; Pishnamaz, Miguel; Mundt, Marion; Sobottke, Rolf; Prescher, Andreas; Stoffel, Marcus; Markert, Bernd; Kobbe, Philipp; Pape, Hans-Christoph; Eysel, Peer; Siewe, Jan
2017-05-01
The purpose of this study was to investigate the range-of-motion after posterior polyetheretherketone-based rod stabilisation combined with a dynamic silicone hinge in order to compare it with titanium rigid stabilisation. Five human cadaveric lumbar spines with four vertebra each (L2 to L5) were tested in a temperature adjustable spine-testing set-up in four trials: (1) native measurement; (2) kinematics after rigid monosegmental titanium rod instrumentation with anterior intervertebral bracing of the segment L4/5; (3) kinematics after hybrid posterior polyetheretherketone rod instrumentation combined with a silicone hinge within the adjacent level (L3/4) and (4) kinematics after additional decompression with laminectomy of L4 and bilateral resection of the inferior articular processes (L3). During all steps, the specimens were loaded quasi-statically with 1°/s with pure moment up to 7.5Nm in flexion/extension, lateral bending and axial rotation. In comparison to the native cadaveric spine, both the titanium device and polyetheretherketone-based device reduce the range-of-motion within the level L4/5 significantly (flexion/extension: reduction of 77%, p<0.001; lateral bending: reduction of 62%, p<0.001; axial rotation: reduction of 71%, p<0.001). There was a clear stabilisation effect after hybrid-instrumentation within the level L3/4, especially in flexion/extension (64%, p<0.001) and lateral bending (62%, p<0.001) but without any effect on the axial rotation. Any temperature dependency has not been observed. Surprisingly, the hybrid device compensates for laminectomy L4 and destabilising procedure within the level L3/4 in comparison to other implants. Further studies must be performed to show its effectiveness regarding the adjacent segment instability. Copyright © 2017 Elsevier Ltd. All rights reserved.
Choi, Jong-Il; Kim, Se-Hoon; Lim, Dong-Jun; Ha, Sung-Kon; Kim, Sang-Dae
2017-01-01
Arthroplasty maintains the biomechanical features of a healthy disc, decreases the adjacent segment disease rate, and decreases the accelerated degeneration rate of the neighboring discs in traditional fusion procedures. However, there are only a few reports on adjacent disc pressure (DP) and facet strain (FS) after lumbar arthroplasty under a physiologic compressive preload. Baseline DP and FS measurements were obtained from five intact cadaveric human lumbosacral spines for different modes of motion. DP was measured by inserting pressure transducer needle tips into the L3-L4 and L5-S1 discs. FS gauges were fixed on both sides of the laminae near the L3-L4, L4-L5, and L5-S1 facet joints. After SB Charité < sup > TM < /sup > III implantation at the L4-L5 level, the measurements were repeated at preload and compared with those of the intact spine. Under the preload condition, the central DP of the upper disc was decreased during extension and bending, and it significantly increased during rotation (p < 0.05). In the lower disc, the central DP insignificantly decreased during bending and increased during extension and flexion. A statistically significant increase in FS was observed during rotation at the operative facet (p < 0.05). Compared to the intact spine, all FS values were insignificantly decreased during lateral bending but increased during axial rotation. In an ex-vivo physiologic preload setting, the SB Charité < sup > TM < /sup > III provided relatively inconsistent and sometimes increased DP or FS at the operative and adjacent levels after arthroplasty.
Restrained Differential Growth: The Initiating Event of Adolescent Idiopathic Scoliosis?
Crijns, Tom Joris; Stadhouder, Agnita; Smit, Theodoor Henri
2017-06-15
An experimental model study and a short review of literature. The purpose of this study was to explore a new hypothesis suggesting that the curvatures seen in adolescent idiopathic scoliosis (AIS) originate from restrained differential growth between the vertebral column and the surrounding musculo-ligamentary structures. Despite decades of research, there is no generally accepted theory on the physical origin of the severe spinal deformations seen in AIS. The prevailing theories tend to focus on left-right asymmetry, rotational instability, or the sagittal spinal profile in idiopathic scoliosis. We test our hypothesis with a physical model of the spine that simulates growth, counteracted by ligaments and muscles, modeled by tethers and springs. Growth of the spine is further restrained by an anterior band representing the thorax, the linea alba, and abdominal musculature. We also explore literature in search of molecular mechanisms that may induce differential growth. Differential growth in the restrained spine model first induces hypokyphosis and mild lateral bending of the thoracic spine, but then suddenly escalates into a scoliotic deformity, consistent with clinical observations of AIS. The band simulating the ventral structures of the body had a pivotal effect on sagittal curvature and the initiation of lateral bending and rotation. In literature, several molecular mechanisms were found that may explain the occurrence of differential growth between the spine and the musculo-ligamentary structures. While AIS is a three-dimensional deformation of the spine, it appears that restrained differential growth in the sagittal plane can result in lateral bending and rotation without a pre-existing left-right asymmetry. This supports the concept that AIS may result from a growth imbalance rather than a local anatomical defect. N/A.
Uribe-Patarroyo, Néstor; Bouma, Brett E.
2015-01-01
We present a new technique for the correction of nonuniform rotation distortion in catheter-based optical coherence tomography (OCT), based on the statistics of speckle between A-lines using intensity-based dynamic light scattering. This technique does not rely on tissue features and can be performed on single frames of data, thereby enabling real-time image correction. We demonstrate its suitability in a gastrointestinal balloon-catheter OCT system, determining the actual rotational speed with high temporal resolution, and present corrected cross-sectional and en face views showing significant enhancement of image quality. PMID:26625040
High-speed coronary rotational angioplasty with the rotablator
NASA Astrophysics Data System (ADS)
Zacca, Nadim M.; Kleiman, Neal S.; Asimacopoulos, P. J.
1992-08-01
Percutaneous mechanical rotational ablation with the rotablator can be used effectively as a stand alone treatment for coronary arterial lesions, including those with angiographic morphology considered unfavorable for balloon angioplasty (eccentric, at bends, bifurcating, calcified, ulcerated, completely occluded_, as well as for balloon angioplasty procedure failures. The use of single rather than multiple burrs without balloon assistance, the use of fewer passes and of the nitroglycerine infusion through the rotablator catheter have considerably shortened the time necessary to complete a rotational atherectomy. Further, the apparently infrequent occurrence of post procedure abrupt closure makes this technique attractive in the clinical management of patients with complex coronary artery lesions.
Esmende, Sean M; Daniels, Alan H; Paller, David J; Koruprolu, Sarath; Palumbo, Mark A; Crisco, Joseph J
2015-01-01
The pendulum testing system is capable of applying physiologic compressive loads without constraining the motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. To examine the dynamic bending stiffness and energy absorption of the cervical spine, with and without implanted cervical total disc replacement (TDR) under simulated physiologic motion. A biomechanical cadaver investigation. Nine unembalmed, frozen human cervical FSUs from levels C3-C4 and C5-C6 were tested on the pendulum system with axial compressive loads of 25, 50, and 100 N before and after TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°, resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and the bending stiffness (Newton-meter/°) was calculated and compared for each testing mode. In flexion/extension, with increasing compressive loading from 25 to 100 N, the average number of cycles to equilibrium for the intact FSUs increased from 6.6 to 19.1, compared with 4.1 to 12.7 after TDR implantation (p<.05 for loads of 50 and 100 N). In flexion, with increasing compressive loading from 25 to 100 N, the bending stiffness of the intact FSUs increased from 0.27 to 0.59 Nm/°, compared with 0.21 to 0.57 Nm/° after TDR implantation. No significant differences were found in stiffness between the intact FSU and the TDR in flexion/extension and lateral bending at any load (p<.05). Cervical FSUs with implanted TDR were found to have similar stiffness, but had greater energy absorption than intact FSUs during cyclic loading with an unconstrained pendulum system. These results provide further insight into the biomechanical behavior of cervical TDR under approximated physiologic loading conditions. Copyright © 2015 Elsevier Inc. All rights reserved.
Electrothermally-Actuated Micromirrors with Bimorph Actuators—Bending-Type and Torsion-Type
Tsai, Cheng-Hua; Tsai, Chun-Wei; Chang, Hsu-Tang; Liu, Shih-Hsiang; Tsai, Jui-Che
2015-01-01
Three different electrothermally-actuated MEMS micromirrors with Cr/Au-Si bimorph actuators are proposed. The devices are fabricated with the SOIMUMPs process developed by MEMSCAP, Inc. (Durham, NC, USA). A silicon-on-insulator MEMS process has been employed for the fabrication of these micromirrors. Electrothermal actuation has achieved a large angular movement in the micromirrors. Application of an external electric current 0.04 A to the bending-type, restricted-torsion-type, and free-torsion-type mirrors achieved rotation angles of 1.69°, 3.28°, and 3.64°, respectively. PMID:26110409
NASA Astrophysics Data System (ADS)
Yue, L.; Suppe, J.
2007-12-01
The Chelungpu and Changhua thrust ramps in central Taiwan show contrasting hanging-wall structural geometries that suggest different kinematics, even though they involve the same stratigraphic section and basal detachment. The Chelungpu thrust shows a classic fault-bend folding geometry, which predicts folding solely by kink-band migration, whereas the hanging wall of the Changhua thrust demonstrates the characteristic geometry of a shear fault-bend folding, which predicts a progressive limb rotation with minor kink-band migration. We test the kinematic predictions of classic and shear fault-bend folding theories by analyzing deformed flights of terraces and coseismic displacements in the Mw=7.6 Chi-Chi earthquake. The Chelungpu terraces shows differences in uplift magnitudes across active axial surfaces that closely approximate the assumptions of classical fault-bend folding, including constant fault-parallel displacement, implying conservation of bed length, and hanging-wall uplift rates that are proportional to the sine of the fault dip. This provides a basis for precise determination of total fault slip since the formation of each terrace and combined with terrace dating gives long- term fault-slip rates for the Chelungpu thrust system. An estimation of the long term fault-slip rate of the Chelungpu thrust in the north Hsinshe terrace yields 15 mm/yr over the last 55 ka, which is similar to the combined shortening rate of 16 mm/y on the Chelungpu and Chushiang thrusts in the south estimated by Simoes et al. in 2006. Evan the coseismic displacements of 3 to 9m in the Chi-Chi earthquake are approximately fault-parallel but have additional transient components that are averaged out over the timescale of terrace deformation, which represents 10-100 large earthquakes. In contrast, terrace deformation in the hanging wall of the Changhua thrust ramp shows progressive limb rotation, as predicted from its shear fault-bend folding geometry, which combined with terrace dating allows an estimation of the long term fault-slip rate of 21 mm/yr over the last 31 ka. A combined shortening rate of 37 mm/yr is obtained for this part of the western Taiwan thrust belt, which is about 45 percent of the total plate-tectonic shortening rate across Taiwan. The Changhua shear fault-bend fold ramp is in the early stages of its development with only 1.7km total displacement whereas the Chelungpu classical fault-bend folding ramp in the same stratigraphy has nearly an order of magnitude more displacement (~14 km). We suggest that shear fault-bend folding may be favored mechanically at low displacement, whereas classical fault-bend folding would be favored at large displacement.
NASA Astrophysics Data System (ADS)
Yue, L.; Suppe, J.
2004-12-01
The Chelungpu and Changhua thrust ramps in central Taiwan show contrasting hanging-wall structural geometries that suggest different kinematics, even though they involve the same stratigraphic section and basal detachment. The Chelungpu thrust shows a classic fault-bend folding geometry, which predicts folding solely by kink-band migration, whereas the hanging wall of the Changhua thrust demonstrates the characteristic geometry of a shear fault-bend folding, which predicts a progressive limb rotation with minor kink-band migration. We test the kinematic predictions of classic and shear fault-bend folding theories by analyzing deformed flights of terraces and coseismic displacements in the Mw=7.6 Chi-Chi earthquake. The Chelungpu terraces shows differences in uplift magnitudes across active axial surfaces that closely approximate the assumptions of classical fault-bend folding, including constant fault-parallel displacement, implying conservation of bed length, and hanging-wall uplift rates that are proportional to the sine of the fault dip. This provides a basis for precise determination of total fault slip since the formation of each terrace and combined with terrace dating gives long- term fault-slip rates for the Chelungpu thrust system. An estimation of the long term fault-slip rate of the Chelungpu thrust in the north Hsinshe terrace yields 15 mm/yr over the last 55 ka, which is similar to the combined shortening rate of 16 mm/y on the Chelungpu and Chushiang thrusts in the south estimated by Simoes et al. in 2006. Evan the coseismic displacements of 3 to 9m in the Chi-Chi earthquake are approximately fault-parallel but have additional transient components that are averaged out over the timescale of terrace deformation, which represents 10-100 large earthquakes. In contrast, terrace deformation in the hanging wall of the Changhua thrust ramp shows progressive limb rotation, as predicted from its shear fault-bend folding geometry, which combined with terrace dating allows an estimation of the long term fault-slip rate of 21 mm/yr over the last 31 ka. A combined shortening rate of 37 mm/yr is obtained for this part of the western Taiwan thrust belt, which is about 45 percent of the total plate-tectonic shortening rate across Taiwan. The Changhua shear fault-bend fold ramp is in the early stages of its development with only 1.7km total displacement whereas the Chelungpu classical fault-bend folding ramp in the same stratigraphy has nearly an order of magnitude more displacement (~14 km). We suggest that shear fault-bend folding may be favored mechanically at low displacement, whereas classical fault-bend folding would be favored at large displacement.
Membrane triangles with corner drilling freedoms. II - The ANDES element
NASA Technical Reports Server (NTRS)
Felippa, Carlos A.; Militello, Carmelo
1992-01-01
This is the second article in a three-part series on the construction of 3-node, 9-dof membrane elements with normal-to-its-plane rotational freedoms (the so-called drilling freedoms) using parametrized variational principles. In this part, one such element is derived within the context of the assumed natural deviatoric strain (ANDES) formulation. The higher-order strains are obtained by constructing three parallel-to-sides pure-bending modes from which natural strains are obtained at the corner points and interpolated over the element. To attain rank sufficiency, an additional higher-order 'torsional' mode, corresponding to equal hierarchical rotations at each corner with all other motions precluded, is incorporated. The resulting formulation has five free parameters. When these parameters are optimized against pure bending by energy balance methods, the resulting element is found to coalesce with the optimal EFF element derived in Part I. Numerical integration as a strain filtering device is found to play a key role in this achievement.
NASA Technical Reports Server (NTRS)
Cramer, B. A.; Davis, J. W.
1975-01-01
A method for predicting permanent cyclic creep deflections in stiffened panel structures was developed. The resulting computer program may be applied to either the time-hardening or strain-hardening theories of creep accumulation. Iterative techniques were used to determine structural rotations, creep strains, and stresses as a function of time. Deflections were determined by numerical integration of structural rotations along the panel length. The analytical approach was developed for analyzing thin-gage entry vehicle metallic-thermal-protection system panels subjected to cyclic bending loads at high temperatures, but may be applied to any panel subjected to bending loads. Predicted panel creep deflections were compared with results from cyclic tests of subsize corrugation and rib-stiffened panels. Empirical equations were developed for each material based on correlation with tensile cyclic creep data and both the subsize panels and tensile specimens were fabricated from the same sheet material. For Vol. 1, see N75-21431.
NASA Astrophysics Data System (ADS)
Sugimoto, Koh-ichi; Hojo, Tomohiko; Mizuno, Yuta
2018-02-01
The effects of fine particle peening conditions on the rotational bending fatigue strength of a vacuum-carburized transformation-induced plasticity-aided martensitic steel with a chemical composition of 0.20 pct C, 1.49 pct Si, 1.50 pct Mn, 0.99 pct Cr, 0.02 pct Mo, and 0.05 pct Nb were investigated for the fabrication of automotive drivetrain parts. The maximum fatigue limit, resulting from high hardness and compressive residual stress in the surface-hardened layer caused by the severe plastic deformation and the strain-induced martensite transformation of the retained austenite during fine particle peening, was obtained by fine particle peening at an arc height of 0.21 mm (N). The high fatigue limit was also a result of the increased martensite fraction and the active plastic relaxation via the strain-induced martensite transformation during fatigue deformation, as well as preferential crack initiation on the surface or at the subsurface.
NASA Astrophysics Data System (ADS)
Le, A. T.; Gross, Eisen C.; Hall, Gregory E.; Sears, Trevor J.
2018-07-01
We report the observation and analysis of spectra in part of the near-infrared spectrum of C2H, originating in rotational levels in the ground and lowest two excited bending vibrational levels of the ground X ˜ 2Σ+ state. In the analysis, we have combined present and previously reported high resolution spectroscopic data for the lower levels involved in the transitions to determine significantly improved molecular constants to describe the fine and hyperfine split rotational levels of the radical in the zero point, v2 = 1 and the 2Σ+ component of v2 = 2 . Two of the upper state vibronic levels involved had not been observed previously. The data and analysis indicate the electronic wavefunction character changes with bending vibrational excitation in the ground state and provide avenues for future measurements of reactivity of the radical as a function of vibrational excitation.
Improvement on the Fatigue Performance of 2024-T4 Alloy by Synergistic Coating Technology
Wang, Xi-Shu; Guo, Xing-Wu; Li, Xu-Dong; Ge, Dong-Yun
2014-01-01
In this paper, rotating bending fatigue tests of 2024-T4 Al alloy with different oxide coatings were carried out. Compared to the uncoated and previously reported oxide coatings of aluminum alloys, the fatigue strength is able to be enhanced by using a novel oxide coating with sealing pore technology. These results indicate that the better the coating surface quality is, the more excellent the fatigue performance under rotating bending fatigue loading is. The improvement on the fatigue performance is mainly because the fatigue crack initiation and the early stage of fatigue crack growth at the coating layer can be delayed after PEO coating with pore sealing. Therefore, it is a so-called synergistic coating technology for various uses, including welding thermal cracks and filling micro-pores. The effects of different oxide coatings on surface hardness, compressive residual stress, morphology and fatigue fracture morphology are discussed. A critical compressive residual stress of about 95–100 MPa is proposed. PMID:28788634
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le, A T.; Gross, Eisen C.; Hall, Gregory E.
Here, we report the observation and analysis of spectra in part of the near-infrared spectrum of C 2H, originating in rotational levels in the ground and lowest two excited bending vibrational levels of the groundmore » $$\\tilde{X}$$ 2Σ+ state. In the analysis, we have combined present and previously reported high resolution spectroscopic data for the lower levels involved in the transitions to determine significantly improved molecular constants to describe the fine and hyperfine split rotational levels of the radical in the zero point, v 2 = 1 and the 2Σ+ component of v 2 = 2. Two of the upper state vibronic levels involved had not been observed previously. The data and analysis indicate the electronic wavefunction character changes with bending vibrational excitation in the ground state and provide avenues for future measurements of reactivity of the radical as a function of vibrational excitation.« less
Le, A T.; Gross, Eisen C.; Hall, Gregory E.; ...
2018-05-15
Here, we report the observation and analysis of spectra in part of the near-infrared spectrum of C 2H, originating in rotational levels in the ground and lowest two excited bending vibrational levels of the groundmore » $$\\tilde{X}$$ 2Σ+ state. In the analysis, we have combined present and previously reported high resolution spectroscopic data for the lower levels involved in the transitions to determine significantly improved molecular constants to describe the fine and hyperfine split rotational levels of the radical in the zero point, v 2 = 1 and the 2Σ+ component of v 2 = 2. Two of the upper state vibronic levels involved had not been observed previously. The data and analysis indicate the electronic wavefunction character changes with bending vibrational excitation in the ground state and provide avenues for future measurements of reactivity of the radical as a function of vibrational excitation.« less
Bending of Light in Modified Gravity at Large Distances
NASA Technical Reports Server (NTRS)
Sultana, Joseph; Kazanas, Demosthenes
2012-01-01
We discuss the bending of light in a recent model for gravity at large distances containing a Rindler type acceleration proposed by Grumiller. We consider the static, spherically symmetric metric with cosmological constant and Rindler-like term 2ar presented in this model, and we use the procedure by Rindler and Ishak. to obtain the bending angle of light in this metric. Earlier work on light bending in this model by Carloni, Grumiller, and Preis, using the method normally employed for asymptotically flat space-times, led to a conflicting result (caused by the Rindler-like term in the metric) of a bending angle that increases with the distance of closest approach r(sub 0) of the light ray from the centrally concentrated spherically symmetric matter distribution. However, when using the alternative approach for light bending in nonasymptotically flat space-times, we show that the linear Rindler-like term produces a small correction to the general relativistic result that is inversely proportional to r(sub 0). This will in turn affect the bounds on Rindler acceleration obtained earlier from light bending and casts doubts on the nature of the linear term 2ar in the metric
A deformation energy-based model for predicting nucleosome dyads and occupancy
Liu, Guoqing; Xing, Yongqiang; Zhao, Hongyu; Wang, Jianying; Shang, Yu; Cai, Lu
2016-01-01
Nucleosome plays an essential role in various cellular processes, such as DNA replication, recombination, and transcription. Hence, it is important to decode the mechanism of nucleosome positioning and identify nucleosome positions in the genome. In this paper, we present a model for predicting nucleosome positioning based on DNA deformation, in which both bending and shearing of the nucleosomal DNA are considered. The model successfully predicted the dyad positions of nucleosomes assembled in vitro and the in vitro map of nucleosomes in Saccharomyces cerevisiae. Applying the model to Caenorhabditis elegans and Drosophila melanogaster, we achieved satisfactory results. Our data also show that shearing energy of nucleosomal DNA outperforms bending energy in nucleosome occupancy prediction and the ability to predict nucleosome dyad positions is attributed to bending energy that is associated with rotational positioning of nucleosomes. PMID:27053067
NASA Technical Reports Server (NTRS)
Myers, William Neil (Inventor)
2005-01-01
Knee braces generally have been rigid in both the knee bending direction and in the knee straightening direction unless a manually operated release is incorporated in them to allow the knee to bend. Desirably a braced knee joint should effectively duplicate the compound, complex, actions of a normal knee. The key to knee braces is the knee joint housing. The housing herein carries a number of cam action pawls. with teeth adapted to engage the internal teeth of a ratchet ring mounted in the housing. Cam action return springs and the shape of the cam action pawl teeth allow rotation of the ratchet ring in a leg straightening direction while still supporting a load. The leg can then be extended during walking while at the same time being prevented by the cam action pawls from buckling in the knee bending direction.
NASA Astrophysics Data System (ADS)
Hohert, Geoffrey; Pahlevaninezhad, Hamid; Lee, Anthony; Lane, Pierre M.
2016-03-01
Endoscopic catheter-based imaging systems that employ a 2-dimensional rotary or 3-dimensional rotary-pullback scanning mechanism require constant angular velocity at the distal tip to ensure correct angular registration of the collected signal. Non-uniform rotational distortion (NURD) - often present due to a variety of mechanical issues - can result in inconsistent position and velocity profiles at the tip, limiting the accuracy of any measurements. Since artifacts like NURD are difficult to identify and characterize during tissue imaging, phantoms with well-defined patterns have been used to quantify position and/or velocity error. In this work we present a fast, versatile, and cost-effective method for making fused deposition modeling 3D printed phantoms for identifying and quantifying NURD errors along an arbitrary user-defined pullback path. Eight evenly-spaced features are present at the same orientation at all points on the path such that deviations from expected geometry can be quantified for the imaging catheter. The features are printed vertically and then folded together around the path to avoid issues with printer head resolution. This method can be adapted for probes of various diameters and for complex imaging paths with multiple bends. We demonstrate imaging using the 3D printed phantoms with a 1mm diameter rotary-pullback OCT catheter and system as a means of objectively evaluating the mechanical performance of similarly constructed probes.
NASA Astrophysics Data System (ADS)
Goren, L.; Castelltort, S.; Klinger, Y.
2014-12-01
The Dead Sea Fault System changes its orientation across Lebanon and forms a restraining bend. The oblique deformation along the Lebanese restraining bend is characterized by a complex suite of tectonic structures, among which, the Yammouneh Fault (YF), is believed to be the main strand that relays deformation from the southern section to the northern section of the Dead Sea Fault System. However, uncertainties regarding slip rates and strain partitioning in Lebanon still prevail. Here, we use morphometric analysis together with analytical and numerical models to constrain rates and modes of distributed and localized deformation along the Lebanese restraining bend.The rivers that drain the western flank of Mount Lebanon show a consistent counterclockwise rotation with respect to an expected orogen perpendicular orientation. Moreover, a pattern of divide disequilibrium in between these rivers emerges from an application of the χ mapping technique, which aims at estimating the degree of geometrical and topological disequilibrium in river networks. These geometrical patterns are compatible with simulation results using a landscape evolution model, which imposes a distributed velocity field along a domain that represents the western flank of Mount Lebanon. We further develop an analytical model that relates the river orientation to a set of kinematic parameters that represents a combined pure and simple shear strain field, and we find the parameters that best explain the present orientation of the western Lebanon rivers. Our results indicate that distributed deformation to the west of the YF takes as much as 30% of the relative Arabia-Sinai plate velocity since the late Miocene, and that the average slip rate along the YF during the same time interval has been 3.8-4.4 mm/yr. The theoretical model can further explain the inferred rotation from Paleomagnetic measurements.
Fitzenz, D.D.; Miller, S.A.
2004-01-01
Understanding the stress field surrounding and driving active fault systems is an important component of mechanistic seismic hazard assessment. We develop and present results from a time-forward three-dimensional (3-D) model of the San Andreas fault system near its Big Bend in southern California. The model boundary conditions are assessed by comparing model and observed tectonic regimes. The model of earthquake generation along two fault segments is used to target measurable properties (e.g., stress orientations, heat flow) that may allow inferences on the stress state on the faults. It is a quasi-static model, where GPS-constrained tectonic loading drives faults modeled as mostly sealed viscoelastic bodies embedded in an elastic half-space subjected to compaction and shear creep. A transpressive tectonic regime develops southwest of the model bend as a result of the tectonic loading and migrates toward the bend because of fault slip. The strength of the model faults is assessed on the basis of stress orientations, stress drop, and overpressures, showing a departure in the behavior of 3-D finite faults compared to models of 1-D or homogeneous infinite faults. At a smaller scale, stress transfers from fault slip transiently induce significant perturbations in the local stress tensors (where the slip profile is very heterogeneous). These stress rotations disappear when subsequent model earthquakes smooth the slip profile. Maps of maximum absolute shear stress emphasize both that (1) future models should include a more continuous representation of the faults and (2) that hydrostatically pressured intact rock is very difficult to break when no material weakness is considered. Copyright 2004 by the American Geophysical Union.
NASA Astrophysics Data System (ADS)
Gorbunov, Michael E.; Kirchengast, Gottfried
2018-01-01
A new reference occultation processing system (rOPS) will include a Global Navigation Satellite System (GNSS) radio occultation (RO) retrieval chain with integrated uncertainty propagation. In this paper, we focus on wave-optics bending angle (BA) retrieval in the lower troposphere and introduce (1) an empirically estimated boundary layer bias (BLB) model then employed to reduce the systematic uncertainty of excess phases and bending angles in about the lowest 2 km of the troposphere and (2) the estimation of (residual) systematic uncertainties and their propagation together with random uncertainties from excess phase to bending angle profiles. Our BLB model describes the estimated bias of the excess phase transferred from the estimated bias of the bending angle, for which the model is built, informed by analyzing refractivity fluctuation statistics shown to induce such biases. The model is derived from regression analysis using a large ensemble of Constellation Observing System for Meteorology, Ionosphere, and Climate (COSMIC) RO observations and concurrent European Centre for Medium-Range Weather Forecasts (ECMWF) analysis fields. It is formulated in terms of predictors and adaptive functions (powers and cross products of predictors), where we use six main predictors derived from observations: impact altitude, latitude, bending angle and its standard deviation, canonical transform (CT) amplitude, and its fluctuation index. Based on an ensemble of test days, independent of the days of data used for the regression analysis to establish the BLB model, we find the model very effective for bias reduction and capable of reducing bending angle and corresponding refractivity biases by about a factor of 5. The estimated residual systematic uncertainty, after the BLB profile subtraction, is lower bounded by the uncertainty from the (indirect) use of ECMWF analysis fields but is significantly lower than the systematic uncertainty without BLB correction. The systematic and random uncertainties are propagated from excess phase to bending angle profiles, using a perturbation approach and the wave-optical method recently introduced by Gorbunov and Kirchengast (2015), starting with estimated excess phase uncertainties. The results are encouraging and this uncertainty propagation approach combined with BLB correction enables a robust reduction and quantification of the uncertainties of excess phases and bending angles in the lower troposphere.
NASA Astrophysics Data System (ADS)
Hou, Hongjuan; Wang, Leilei; Wang, Rui; Yang, Yanzhao
2017-04-01
A turbocharger compressor working in commercial vehicles, especially in some passenger cars, often works together with some pipes with complicated geometry as an air intake system, due to limit of available space in internal combustion engine compartments. These pipes may generate various distortions of physical parameters of the air at the inlet of the compressor and therefore the compressor aerodynamic performance deteriorates. Sometimes, the turbocharging engine fails to work at some operation points. This paper investigates the effects of various swirl distortions induced by different bending-torsional intake ducts on the aerodynamic performance of a turbocharger compressor by both 3D numerical simulations and experimental measurements. It was found that at the outlet of the pipes the different inlet ducts can generate different swirl distortions, twin vortices and bulk-like vortices with different rotating directions. Among them, the bulk-like vortices not only affect seriously the pressure distribution in the impeller domain, but also significantly deteriorate the compressor performance, especially at high flow rate region. And the rotating direction of the bulk-like vortices is also closely associated with the efficiency penalty. Besides the efficiency, the transient flow rate through a single impeller channel, or the asymmetric mass flow crossing the whole impeller, can be influenced by two disturbances. One is from the upstream bending-torsional ducts; other one is from the downstream volute.
Smith, Aimée C; Roberts, Jonathan R; Wallace, Eric S; Kong, Pui; Forrester, Stephanie E
2016-02-01
Two-dimensional methods have been used to compute trunk kinematic variables (flexion/extension, lateral bend, axial rotation) and X-factor (difference in axial rotation between trunk and pelvis) during the golf swing. Recent X-factor studies advocated three-dimensional (3D) analysis due to the errors associated with two-dimensional (2D) methods, but this has not been investigated for all trunk kinematic variables. The purpose of this study was to compare trunk kinematic variables and X-factor calculated by 2D and 3D methods to examine how different approaches influenced their profiles during the swing. Trunk kinematic variables and X-factor were calculated for golfers from vectors projected onto the global laboratory planes and from 3D segment angles. Trunk kinematic variable profiles were similar in shape; however, there were statistically significant differences in trunk flexion (-6.5 ± 3.6°) at top of backswing and trunk right-side lateral bend (8.7 ± 2.9°) at impact. Differences between 2D and 3D X-factor (approximately 16°) could largely be explained by projection errors introduced to the 2D analysis through flexion and lateral bend of the trunk and pelvis segments. The results support the need to use a 3D method for kinematic data calculation to accurately analyze the golf swing.
Nonlinear model of a rotating hub-beams structure: Equations of motion
NASA Astrophysics Data System (ADS)
Warminski, Jerzy
2018-01-01
Dynamics of a rotating structure composed of a rigid hub and flexible beams is presented in the paper. A nonlinear model of a beam takes into account bending, extension and nonlinear curvature. The influence of geometric nonlinearity and nonconstant angular velocity on dynamics of the rotating structure is presented. The exact equations of motion and associated boundary conditions are derived on the basis of the Hamilton's principle. The simplification of the exact nonlinear mathematical model is proposed taking into account the second order approximation. The reduced partial differential equations of motion together with associated boundary conditions can be used to study natural or forced vibrations of a rotating structure considering constant or nonconstant angular speed of a rigid hub and an arbitrary number of flexible blades.
NASA Astrophysics Data System (ADS)
Nazari, Esmaeil; Löbbe, Christian; Gallus, Stefan; Izadyar, S. Ahmad; Tekkaya, A. Erman
2018-05-01
The incremental tube forming (ITF) is a process combination of the kinematic tube bending and spinning to shape high strength and tailored tubes with variable diameters and thicknesses. In contrast to conventional bending methods, the compressive stress superposition by the spinning process facilitates low bending stresses, so that geometrical errors are avoided and the shape accuracy is improved. The study reveals the interaction of plastic strains of the rolling and bending process through an explicit FEM investigation. For this purpose, the three-dimensional machine set-up is discretized and modeled in terms of the fully disclosed spinning process during the gradual deflection of the tube end for bending. The analysis shows that, depending on the forming tool shape, the stress superposition is accompanied by high plastic strains. Furthermore, this phenomenon is explained by the three dimensional normal and shear strains during the incremental spinning. Analyzing the strains history also shows a nonlinearity between the strains by bending and spinning. It is also shown that process parameters like rotational velocity of the spinning rolls have a huge influence on the deformation pattern. Finally, the method is used for the manufacturing of an example product, which reveals the high process flexibility. In one clamp a component with a graded wall thickness and outside diameter along the longitudinal axis is produced.
Bending stiffness, torsional stability, and insertion force of cementless femoral stems.
Incavo, S J; Johnson, C C; Churchill, D L; Beynnon, B D
2001-04-01
In cementless total hip arthroplasty, increased femoral stem flexibility and decreased fracture propensity are desirable characteristics. The slotting and tapering of the stem have been introduced to achieve this. These features should not, however, be allowed to interfere with the ability of the distal stem to provide initial mechanical stability, especially under rotation. This study was done to investigate the ability of slotted and tapered stem designs to reduce stiffness and insertion force while still maintaining adequate torsional strength. The torsional strength, maximum insertion force, and insertional work of straight, slotted, and taper stems were measured by inserting each type into rigid polyurethane foam and torque testing to failure. Bending stiffness of each stem design was calculated using numerical methods. When compared to a straight stem, a unislot stem has similar torsional strength, maximum insertional force, and work of insertion. The bending stiffness is decreased by 19% to 82% depending on the bending direction. A trislot design decreased torque strength by 29%, maximal insertion force by 36%, and work by 11%. Bending stiffness was decreased by 74% and was not dependent on bending direction. A 0.5-mm taper decreased torque strength by 11% and insertional work by 14%. No difference was seen in maximum insertional force. We conclude that the design features studied (slots and taper) are effective in decreasing stem stiffness and reducing fracture propensity.
A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy.
Boswell, Sarah A; Jeraj, Robert; Ruchala, Kenneth J; Olivera, Gustavo H; Jaradat, Hazim A; James, Joshua A; Gutierrez, Alonso; Pearson, Dave; Frank, Gary; Mackie, T Rock
2005-06-01
An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is proposed for a treatment couch that is restricted to motion along translational axes. In tomotherapy, only a narrow superior/inferior section of the target receives a dose at any instant, thus rotations in the sagittal and coronal planes may be approximately corrected for by very slow continuous couch motion in a direction perpendicular to the scanning direction. Results from proof-of-principle tests indicate that the method improves the accuracy of treatment delivery, especially for long and narrow targets. Rotational corrections about an axis perpendicular to the transverse plane continue to be implemented easily in tomotherapy by adjustment of the initial gantry angle.
Farr, Sebastian; Kranzl, Andreas; Hahne, Julia; Ganger, Rudolf
2017-08-01
Literature suggests that children and adolescents with idiopathic genua valga present with considerable gait deviations in frontal and transverse planes, including altered frontal knee moments, reduced external knee rotation, and increased external hip rotation. This study aimed to evaluate gait parameters in these patients after surgical correction using tension band plating (TBP). We prospectively evaluated 24 consecutive, skeletally immature patients, who received full-length standing radiographs and three-dimensional gait analysis before and after correction, and compared the results observed to a group of 11 typically developing peers. Prior to TBP the cohort showed significantly decreased (worse) internal frontal knee moments compared to the control group. After axis correction the mean and maximum knee moments changed significantly into normalized knee moments (p < 0.0001). In the transverse plane, only the foot progression angle (p = 0.020) changed significantly following intervention. Post-correction knee moments were similar to controls (p = 0.175), but the patient cohort exhibited a significantly decreased knee external rotation (p = 0.004) and increased external hip rotation (p < 0.001) during gait. In addition, the effect of transverse plane changes on knee moments in patients with restored, straight limb axis was calculated. Hence, patients with restored alignment but persistence of decreased external knee rotation demonstrated significantly greater knee moments than those without rotational abnormalities (p = 0.001). This study found that frontal knee moments during gait normalized in children with idiopathic genua valga after surgery. However, decreased external knee rotation and increased external hip rotation during gait persisted in the study cohort. Despite radiological correction, decreased external rotation during gait was associated with increases in medial knee loading. Surgical correction for children with genua valga but normal knee moments may be detrimental, due to redistribution of dynamic knee loading into the opposite joint compartment. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1617-1624, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Sedaghat, Mohammad Reza; Daneshvar, Ramin; Kargozar, Abbas; Derakhshan, Akbar; Daraei, Mona
2010-12-01
To evaluate and compare central corneal thickness measurements using rotating Scheimpflug camera, scanning-slit topography, and ultrasound pachymetry in virgin, healthy corneas. Prospective, observational, cross-sectional study. Central corneal thickness in 157 healthy eyes of 157 patients without ocular abnormalities other than refractive errors was measured, in a sequential order, once with rotating Scheimpflug camera and scanning-slit topography and 3 times with ultrasound pachymetry as the last part of examination. All measurements were performed by a single experienced examiner. The results from scanning-slit topography are given with and without correction for "acoustic correction factor" of 0.92. The average measurements of central corneal thickness by rotating Scheimpflug imaging, scanning-slit pachymetry, and ultrasound were 537.15 ± 32.98 μm, 542.06 ± 39.04 μm, and 544.07 ± 34.75 μm, respectively. The mean differences between modalities were 6.92 μm between rotating Scheimpflug and ultrasound (P < .0001), 2.01 μm between corrected scanning-slit and ultrasound (P = .204), and 4.91 μm between corrected scanning-slit and rotating Scheimpflug imaging (P = .001). According to Bland-Altman analysis, highest agreement was between ultrasonic and rotating Scheimpflug pachymetry. In the assessment of normal corneas, rotating Scheimpflug topography measures central corneal thickness values with higher agreement to ultrasound pachymetry. Copyright © 2010 Elsevier Inc. All rights reserved.
Sidiq, Mohsin; Yousuf, Asif; Bhat, Manohar; Sharma, Rajesh; Bhargava, Neha; Ganta, Shravani
2015-01-01
The aim of this case study was to report a potentially convenient approach instead of a conventional orthodontic procedure for correcting severe rotation of anterior tooth of an 11-year-old Indian boy, with a mixed dentition class I malocclusion. The child reported seeking treatment for severely rotated upper right central incisor with mesiodens and a single tooth crossbite. The supernumerary tooth was first extracted and bondable buttons were placed on the rotated tooth, an appliance composed of a removable plate with Adam's clasp with distal extension and a loop for engagement of elastics was delivered. Circumferential supracrestal fibrotomy was performed on the corrected derotated tooth. Then, Hawley's appliance with a z-spring and posterior bite plane was fabricated and placed for correction of crossbite. Thus, this removable appliance can be a simplified and a cost-effective treatment alternative for derotation of anterior tooth, especially during the mixed dentition period. How to cite this article: Sidiq M, Yousuf A, Bhat M, Sharma R, Bhargava N, Ganta S. Correction of a Severely Rotated Maxillary Incisor by Elastics in Mixed Dentition Complicated by a Mesiodens. Int J Clin Pediatr Dent 2015;8(3):234-238.
Sidiq, Mohsin; Bhat, Manohar; Sharma, Rajesh; Bhargava, Neha; Ganta, Shravani
2015-01-01
ABSTRACT The aim of this case study was to report a potentially convenient approach instead of a conventional orthodontic procedure for correcting severe rotation of anterior tooth of an 11-year-old Indian boy, with a mixed dentition class I malocclusion. The child reported seeking treatment for severely rotated upper right central incisor with mesiodens and a single tooth crossbite. The supernumerary tooth was first extracted and bondable buttons were placed on the rotated tooth, an appliance composed of a removable plate with Adam’s clasp with distal extension and a loop for engagement of elastics was delivered. Circumferential supracrestal fibrotomy was performed on the corrected derotated tooth. Then, Hawley’s appliance with a z-spring and posterior bite plane was fabricated and placed for correction of crossbite. Thus, this removable appliance can be a simplified and a cost-effective treatment alternative for derotation of anterior tooth, especially during the mixed dentition period. How to cite this article: Sidiq M, Yousuf A, Bhat M, Sharma R, Bhargava N, Ganta S. Correction of a Severely Rotated Maxillary Incisor by Elastics in Mixed Dentition Complicated by a Mesiodens. Int J Clin Pediatr Dent 2015;8(3):234-238. PMID:26604544
A Study of Two-Equation Turbulence Models on the Elliptic Streamline Flow
NASA Technical Reports Server (NTRS)
Blaisdell, Gregory A.; Qin, Jim H.; Shariff, Karim; Rai, Man Mohan (Technical Monitor)
1995-01-01
Several two-equation turbulence models are compared to data from direct numerical simulations (DNS) of the homogeneous elliptic streamline flow, which combines rotation and strain. The models considered include standard two-equation models and models with corrections for rotational effects. Most of the rotational corrections modify the dissipation rate equation to account for the reduced dissipation rate in rotating turbulent flows, however, the DNS data shows that the production term in the turbulent kinetic energy equation is not modeled correctly by these models. Nonlinear relations for the Reynolds stresses are considered as a means of modifying the production term. Implications for the modeling of turbulent vortices will be discussed.
Torsional Carbon Nanotube Artificial Muscles
NASA Astrophysics Data System (ADS)
Foroughi, Javad; Spinks, Geoffrey M.; Wallace, Gordon G.; Oh, Jiyoung; Kozlov, Mikhail E.; Fang, Shaoli; Mirfakhrai, Tissaphern; Madden, John D. W.; Shin, Min Kyoon; Kim, Seon Jeong; Baughman, Ray H.
2011-10-01
Rotary motors of conventional design can be rather complex and are therefore difficult to miniaturize; previous carbon nanotube artificial muscles provide contraction and bending, but not rotation. We show that an electrolyte-filled twist-spun carbon nanotube yarn, much thinner than a human hair, functions as a torsional artificial muscle in a simple three-electrode electrochemical system, providing a reversible 15,000° rotation and 590 revolutions per minute. A hydrostatic actuation mechanism, as seen in muscular hydrostats in nature, explains the simultaneous occurrence of lengthwise contraction and torsional rotation during the yarn volume increase caused by electrochemical double-layer charge injection. The use of a torsional yarn muscle as a mixer for a fluidic chip is demonstrated.
Rotary powder feed through apparatus
Lewis, Gary K.; Less, Richard M.
2001-01-01
A device for increasing the uniformity of solids within a solids fabrication system, such as a direct light fabrication (DLF) system in which gas entrained powders are passed through the focal point of a moving high-power light which fuses the particles in the powder to a surface being built up in layers. The invention provides a feed through interface wherein gas entrained powders input from stationary input lines are coupled to a rotating head of the fabrication system. The invention eliminates the need to provide additional slack in the feed lines to accommodate head rotation, and therefore reduces feed line bending movements which induce non-uniform feeding of gas entrained powder to a rotating head.
METHOD AND APPARATUS FOR EFFECTING THERMAL BONDS
Monson, H.O.; Jaross, R.A.
1961-10-17
A device is described for completing the alkali metal bend between a fael element and its jacket. It consists of a heater and electo1nagic surrounding the fael element so tbat while it is heated a rotating magnetic field will agirate the alkali metal and work out void spaces. (AEC)
Mean-flow measurements of the flow field diffusing bend
NASA Technical Reports Server (NTRS)
Mcmillan, O. J.
1982-01-01
Time-average measurements of the low-speed turbulent flow in a diffusing bend are presented. The experimental geometry consists of parallel top and bottom walls and curved diverging side walls. The turning of the center line of this channel is 40 deg, the area ratio is 1.5 and the ratios of height and center-line length to throat width are 1.5 and 3, respectively. The diffusing bend is preceded and followed by straight constant area sections. The inlet boundary layers on the parallel walls are artificially thickened and occupy about 30% of the channel height; those on the side walls develop naturally and are about half as thick. The free-stream speed at the inlet was approximately 30 m/sec for all the measurements. Inlet boundary layer mean velocity and turbulence intensity profiles are presented, as are data for wall static pressures, and at six cross sections, surveys of the velocity-vector and static-pressure fields. The dominant feature of the flow field is a pair of counter-rotating streamwise vortices formed by the cross-stream pressure gradient in the bend on which an overall deceleration is superimposed.
Item Type and Gender Differences on the Mental Rotations Test
ERIC Educational Resources Information Center
Voyer, Daniel; Doyle, Randi A.
2010-01-01
This study investigated gender differences on the Mental Rotations Test (MRT) as a function of item and response types. Accordingly, 86 male and 109 female undergraduate students completed the MRT without time limits. Responses were coded as reflecting two correct (CC), one correct and one wrong (CW), two wrong (WW), one correct and one blank…
Eichholz, Kurt M; Hitchon, Patrick W; From, Aaron; Rubenbauer, Paige; Nakamura, Satoshi; Lim, Tae Hong; Torner, James
2004-07-01
Thoracolumbar burst fractures frequently require surgical intervention. Although the use of either anterior or posterior instrumentation has advantages and disadvantages, there have been few studies in which these two approaches have been compared biomechanically. Ten human cadaveric spines were subjected to subtotal L-3 corpectomy. In five spines placement of L-3 wooden strut grafts with lateral L2-4 dual rod and screw instrumentation was performed. Five other spines underwent L1-5 pedicle screw fixation. The spines were fatigued between steps of the experiment. The spines were load tested with pure moments of 1.5, 3, 4.5, and 6 Nm in the intact state and after placement of instrumentation in six degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In axial rotation posterior instrumentation significantly increased spinal rigidity compared with that of the intact state, whereas anterior instrumentation did not. Combined anterior-posterior instrumentation did not significantly increase the rigidity of the spine when compared with anterior or posterior instrumentation alone. Posterior instrumentation alone provided a greater reduction in angular rotation compared with anterior instrumentation alone in all degrees of freedom; however, statistical significance was achieved only in extension at 6 Nm. The increased rigidity provided by pedicle screw instrumentation compared with the intact state or with anterior instrumentation is due to the longer construct spanning five levels and the three-column engagement of the pedicle screws. The decision to use anterior or posterior instrumentation should be based on the clinical necessity of canal decompression and correction of angulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imura, K; Fujibuchi, T; Hirata, H
Purpose: Patient set-up skills in radiotherapy treatment room have a great influence on treatment effect for image guided radiotherapy. In this study, we have developed the training system for improving practical set-up skills considering rotational correction in the virtual environment away from the pressure of actual treatment room by using three-dimensional computer graphic (3DCG) engine. Methods: The treatment room for external beam radiotherapy was reproduced in the virtual environment by using 3DCG engine (Unity). The viewpoints to perform patient set-up in the virtual treatment room were arranged in both sides of the virtual operable treatment couch to assume actual performancemore » by two clinical staffs. The position errors to mechanical isocenter considering alignment between skin marker and laser on the virtual patient model were displayed by utilizing numerical values expressed in SI units and the directions of arrow marks. The rotational errors calculated with a point on the virtual body axis as the center of each rotation axis for the virtual environment were corrected by adjusting rotational position of the body phantom wound the belt with gyroscope preparing on table in a real space. These rotational errors were evaluated by describing vector outer product operations and trigonometric functions in the script for patient set-up technique. Results: The viewpoints in the virtual environment allowed individual user to visually recognize the position discrepancy to mechanical isocenter until eliminating the positional errors of several millimeters. The rotational errors between the two points calculated with the center point could be efficiently corrected to display the minimum technique mathematically by utilizing the script. Conclusion: By utilizing the script to correct the rotational errors as well as accurate positional recognition for patient set-up technique, the training system developed for improving patient set-up skills enabled individual user to indicate efficient positional correction methods easily.« less
Correction for specimen movement and rotation errors for in-vivo Optical Projection Tomography
Birk, Udo Jochen; Rieckher, Matthias; Konstantinides, Nikos; Darrell, Alex; Sarasa-Renedo, Ana; Meyer, Heiko; Tavernarakis, Nektarios; Ripoll, Jorge
2010-01-01
The application of optical projection tomography to in-vivo experiments is limited by specimen movement during the acquisition. We present a set of mathematical correction methods applied to the acquired data stacks to correct for movement in both directions of the image plane. These methods have been applied to correct experimental data taken from in-vivo optical projection tomography experiments in Caenorhabditis elegans. Successful reconstructions for both fluorescence and white light (absorption) measurements are shown. Since no difference between movement of the animal and movement of the rotation axis is made, this approach at the same time removes artifacts due to mechanical drifts and errors in the assumed center of rotation. PMID:21258448
Park, Kyue-Nam; Kwon, Oh-Yun; Kim, Si-Hyun; Jeon, In-Cheol
2017-03-01
The purpose of this study was to compare the immediate effects of axial neck rotation training (Axi-NRT) with and without real-time visual feedback (VF) using a smartphone inclinometer on the range of motion (ROM) for axial neck rotation and the onset of compensatory neck lateral bending and extension during active neck rotation. Twenty participants with restricted ROM for neck rotation but no neck pain (21.1 ± 1.6 years and 8 males, 12 females) were recruited for Axi-NRT with VF, and twenty age- and gender-matched participants with restricted ROM for neck rotation were recruited for Axi-NRT without VF. Changes in ROM for neck rotation and the onset time of compensatory neck movement during active neck rotation were measured using an electromagnetic tracking system. Axi-NRT with VF was more effective in increasing ROM for neck rotation and decreasing and delaying the onset of compensatory neck movements during active neck rotation compared with Axi-NRT without VF. Repeated Axi-NRT using VF is useful to educate participants in maintaining the axis of the cervical spine and to increase ROM for axial neck rotation with less compensatory neck motion in participants with a restricted range of neck rotations.
Dissociation energy and dynamics of water clusters
NASA Astrophysics Data System (ADS)
Ch'ng, Lee Chiat
The state-to-state vibrational predissociation (VP) dynamics of water clusters were studied following excitation of a vibrational mode of each cluster. Velocity-map imaging (VMI) and resonance-enhanced multiphoton ionization (REMPI) were used to determine pair-correlated center-of-mass translational energy distributions. Product energy distributions and dissociation energies were determined. Following vibrational excitation of the HCl stretch fundamental of the HCl-H2O dimer, HCl fragments were detected by 2 + 1 REMPI via the f 3□2(nu' = 0) ← X 1Sigma+(nu'' = 0) and V1Sigma + (nu' = 11 and 12) ← X1Sigma+ (nu'' = 0) transitions. REMPI spectra clearly show HCl from dissociation produced in the ground vibrational state with J'' up to 11. The fragments' center-of-mass translational energy distributions were determined from images of selected rotational states of HCl and were converted to rotational state distributions of the water cofragment. All the distributions could be fit well when using a dimer dissociation energy of bond dissociation energy D0 = 1334 +/- 10 cm--1. The rotational distributions in the water cofragment pair-correlated with specific rotational states of HCl appear nonstatistical when compared to predictions of the statistical phase space theory. A detailed analysis of pair-correlated state distributions was complicated by the large number of water rotational states available, but the data show that the water rotational populations increase with decreasing translational energy. H2O fragments of this dimer were detected by 2 + 1 REMPI via the C˜1B1(000) ← X˜1A1(000) transition. REMPI clearly shows that H2O from dissociation is produced in the ground vibrational state. The fragment's center-of-mass translational energy distributions were determined from images of selected rotational states of H2O and were converted to rotational state distributions of the HCl cofragment. The distributions gave D0 = 1334 +/- 10 cm --1 and show a clear preference for rotational levels in the HCl fragment that minimize translational energy release. The usefulness of 2 + 1 REMPI detection of water fragment is discussed. The hydrogen bonding in water is dominated by pair-wise dimer interactions, and the predissociation of the water dimer following vibrational excitation is reported. The measured D0 values of (H 2O)2 and (D2O)2, 1105 and 1244 +/- 10 cm--1, respectively, are in excellent agreement with the calculated values of 1103 and 1244 +/- 5 cm--1. Pair-correlated water fragment rovibrational state distributions following vibrational predissociation of (H2O)2 and (D2O) 2 were obtained upon excitation of the hydrogen bonded OH and OD stretch fundamentals, respectively. Quasiclassical trajectory calculations, using an accurate full-dimensional potential energy surface, are in accord with and help to elucidate experiment. Experiment and theory find predominant excitation of the fragment bending mode upon hydrogen bond breaking. A minor channel is also observed in which both fragments are in the ground vibrational state and are highly rotationally excited. The theoretical calculations reveal equal probability of bending excitation in the donor and acceptor subunits, which is a result of interchange of donor and acceptor roles. The rotational distributions associated with the major channel, in which one water fragment has one quantum of bend, and the minor channel with both water fragments in the ground vibrational state are calculated, and are in agreement with experiment. (Abstract shortened by UMI.)
NASA Astrophysics Data System (ADS)
Dörr, Dominik; Schirmaier, Fabian J.; Henning, Frank; Kärger, Luise
2017-10-01
Finite Element (FE) forming simulation offers the possibility of a detailed analysis of the deformation behavior of multilayered thermoplastic blanks during forming, considering material behavior and process conditions. Rate-dependent bending behavior is a material characteristic, which is so far not considered in FE forming simulation of pre-impregnated, continuously fiber reinforced polymers (CFRPs). Therefore, an approach for modeling viscoelastic bending behavior in FE composite forming simulation is presented in this work. The presented approach accounts for the distinct rate-dependent bending behavior of e.g. thermoplastic CFRPs at process conditions. The approach is based on a Voigt-Kelvin (VK) and a generalized Maxwell (GM) approach, implemented within a FE forming simulation framework implemented in several user-subroutines of the commercially available FE solver Abaqus. The VK, GM, as well as purely elastic bending modeling approaches are parameterized according to dynamic bending characterization results for a PA6-CF UD-tape. It is found that only the GM approach is capable to represent the bending deformation characteristic for all of the considered bending deformation rates. The parameterized bending modeling approaches are applied to a hemisphere test and to a generic geometry. A comparison of the forming simulation results of the generic geometry to experimental tests show a good agreement between simulation and experiments. Furthermore, the simulation results reveal that especially a correct modeling of the initial bending stiffness is relevant for the prediction of wrinkling behavior, as a similar onset of wrinkles is observed for the GM, the VK and an elastic approach, fitted to the stiffness observed in the dynamic rheometer test for low curvatures. Hence, characterization and modeling of rate-dependent bending behavior is crucial for FE forming simulation of thermoplastic CFRPs.
Correcting a Widespread Error concerning the Angular Velocity of a Rotating Rigid Body.
ERIC Educational Resources Information Center
Leubner, C.
1981-01-01
Since many texts use an incorrect argument in obtaining the instantaneous velocity of a rotating body, a correct and concise derivation of this quantity for a rather general case is given. (Author/SK)
[Temporal rotation skin flap combined with cartilage plasty for correcting cryptotia].
Li, Gaofeng; Luo, Tao; Ding, Wei; Ouyang, Huawei; Liu, Wanli; Tan, Jun
2014-01-01
To explore the therapeutic effect of the temporal rotation flap combined with cartilage plasty for cryptotia correction. From January 2009 to June 2012, 8 cases with cryptotia (10 ears) were treated. After complete dissection of the cartilage adhesion, the cartilage was reshaped by suture to restore its appearance. Then the temporal triangular rotation flap was transferred to cover the wound. No hematoma, infection or flap necrosis happened. The follow-up period ranged from 3 months to 1 year, with an average of (6.88 +/- 2.85) months. The ear appearance kept stable with no recurrence and inconspicuous scar. Satisfactory result was achieved. Temporal rotation flap combined with cartilage plasty is a good option for correction of mild or moderate cryptotia.
Costagli, Mauro; Waggoner, R Allen; Ueno, Kenichi; Tanaka, Keiji; Cheng, Kang
2009-04-15
In functional magnetic resonance imaging (fMRI), even subvoxel motion dramatically corrupts the blood oxygenation level-dependent (BOLD) signal, invalidating the assumption that intensity variation in time is primarily due to neuronal activity. Thus, correction of the subject's head movements is a fundamental step to be performed prior to data analysis. Most motion correction techniques register a series of volumes assuming that rigid body motion, characterized by rotational and translational parameters, occurs. Unlike the most widely used applications for fMRI data processing, which correct motion in the image domain by numerically estimating rotational and translational components simultaneously, the algorithm presented here operates in a three-dimensional k-space, to decouple and correct rotations and translations independently, offering new ways and more flexible procedures to estimate the parameters of interest. We developed an implementation of this method in MATLAB, and tested it on both simulated and experimental data. Its performance was quantified in terms of square differences and center of mass stability across time. Our data show that the algorithm proposed here successfully corrects for rigid-body motion, and its employment in future fMRI studies is feasible and promising.
NASA Astrophysics Data System (ADS)
Little, Timothy A.
1990-08-01
The Border Ranges fault system (BRFS) bounds the inboard edge of the subduction-accretion complex of southern Alaska. In Eocene time a central segment of this fault system was reactivated as a zone of dextral wrench- and oblique-slip faulting having a cumulative strike-slip offset of at least several tens of kilometers, but probably less than 100 km. Early wrench folds are upright, trend at less than 45° to the strike of adjacent faults and developed with fold axes oriented subparallel to the axis of maximum incremental stretch λ1. These en echelon folds rotated and tightened with progressive deformation and then were overprinted by younger wrench folds that trend at about 60° to adjacent throughgoing faults. The latter folds are interpreted as forming during a late increment of distributed wrench deformation within the BRFS that included a component of extension (divergence) orthogonal to the mean strike of the fault system. A sharp releasing bend in exposures of a strike-slip fault originally at >4 km depth today coincides with a narrow pull-apart graben bounded by oblique-normal faults that dip toward the basin. Widening of this pull-apart graben by brittle faulting and dike intrusion accommodated less than 2 km of strike-slip and was a late-stage phenomenon, possibly occurring at supracrustal levels. Prior to formation of this graben during a period of predominantly ductile deformation at deeper structural levels, wrench-folded rocks on one side of the nonplanar fault were translated around the releasing bend without significant faulting or loss of coherence. Kinematically, the earlier deformation was accomplished by fault-bend folding and rotation of a relatively deformable block as it passed through a system of upright megakinks. Such a ductile mechanism of fault block translation around a strike-slip bend may be typical of intermediate levels of the crust beneath pull-apart grabens and may be transitional downward into heterogeneous laminar flow occuring along curved segments of ductile shear zones. Some degree of fault-bend folding of strike-slip fault blocks around releasing bends may be one reason why the amount of extension measured across natural pull-apart basins is commonly observed to be less than the amount of strike-slip along their master faults.
Behavior of plywood and fiberglass steel composite tube structures subjected to impact loading
NASA Astrophysics Data System (ADS)
Armaghani, Seyamend Bilind
Paratransit buses are custom built as the major vehicle manufacturer produces the custom built passenger cage installed on the chassis for the Paratransit bus. In order for these Paratransit bus members to be sufficient, they have to be evaluated for crashworthiness and energy absorption. This has prompted Florida Department of Transportation (FDOT) to fund research for the safety evaluation of Paratransit busses consisting of crash and safety analysis. There has been a large body of research done on steel subjected to static loads, but more research is needed for steel applied under dynamic loading and high speeds in order to improve crashworthiness in events such as rollovers and side impacts. Bare steel Hollow Structural Section (HSS) tubing are used a lot as structural members of Paratransit buses because of their lightness and progressive buckling under loading. The research will be conducted on quantifying the tubing's behavior under bending by conducting static three point bending and impact loading tests. In addition to the bare tubing, plywood and fiberglass composites are investigated because they are both strong and lightweight and their behavior under dynamic loading hasn't been quantified. As a result, the main purpose of this research is to quantify the differences between the dynamic and static behavior of plywood steel composite and fiberglass steel composite tubing and compare these findings with those of bare steel tubing. The differences will be quantified using detailed and thorough experiments that will examine the composites behavior under both static and dynamic loading. These tests will determine if there are any advantages of using the composite materials and thus allow for recommendations to be made to the FDOT with the goal of improving the safety of Paratransit busses. Tensile tests were conducted to determine the material properties of the tested specimens. Before the static and dynamic experiments are run to investigate the differences between static and dynamic behavior, Preliminary three point bending testing was conducted to determine the parameters for the final experiments. Static bending testing was conducted on the bare, plywood composite, and fiberglass composite steel tubing. The point of these experiments was to produce a Moment vs. Rotation plot to determine the specimens' maximum moments and their associated rotation, as that is when the steel buckles and fails. The dynamic three point bending experiments were conducted using the impact loading apparatus and had the same purpose as the static experiments. For both static and dynamic experiments, the performances of the different types of specimens were compared based upon their Moment vs. Rotation plots. This will determine the effect that the composite has on the rotation and maximum moment at which the tubing fails. After conducting these experiments, amplification factors were established for each specimen by comparing the maximum moment and their associated rotation between static and dynamic testing. lambda was calculated to quantify the ratio between the static and dynamic maximum moments. beta was used to quantify the ratio between the rotation needed to produce the maximum moment between static and dynamic events. A small amplification factor denotes that material performs well under impact loading and the material doesn't experience dramatic change in behavior during dynamic events. Amplification factors were compared between the bare, plywood, and fiberglass composite steel tubing in order to evaluate the performance of the composites. After comparing the amplification factors of the different types of tubing, recommendations can be made. Fiberglass and plywood composite were shown to be valuable because it decreased the effect of dynamic forces as beta was reduced by a factor of 2 in comparison to bare tubing. Based upon the amplification factors, it was recommended to use 14 gauge fiberglass composite tubing as Paratransit bus structural members because it was affected the least by dynamic loading.
Rotational molding of pultruded profiles reinforced polyethylene
NASA Astrophysics Data System (ADS)
Greco, Antonio; Maffezzoli, Alfonso; Romano, Giorgio
2014-05-01
The aim of this paper is the production of fiber reinforced LLDPE components by rotational molding. To this purpose, a process upgrade was developed, for the incorporation of pultruded tapes in the rotational molding cycle. Pultruded tapes, made of 50% by weight of glass fibers dispersed in a high density polyethylene(HDPE) matrix, were glued on the internal surface of a cubic mold, and rotational molding process was run using the same processing conditions used for conventional LLDPE processing. During processing, melting of LLDPE powders and of HDPE allowed to incorporate the tapes inside rotational molded LLDPE. The glass fiber reinforced prototypes were characterized in terms of mechanical properties. Plate bending tests were performed on the square faces extracted from the rotational molded product. The rotational molding products were also subjected to internal hydrostatic pressure tests up to 10 bar. In any case, no failure of the cubic samples was observed. In both cases, it was found that addition of a single pultruded strips, which corresponds to addition of about 0.6% by weight of glass fibers, involved an increase of the stiffness of the faces by about 25%.
Tamhane, Ashish A; Arfanakis, Konstantinos
2009-07-01
Periodically-rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and Turboprop MRI are characterized by greatly reduced sensitivity to motion, compared to their predecessors, fast spin-echo (FSE) and gradient and spin-echo (GRASE), respectively. This is due to the inherent self-navigation and motion correction of PROPELLER-based techniques. However, it is unknown how various acquisition parameters that determine k-space sampling affect the accuracy of motion correction in PROPELLER and Turboprop MRI. The goal of this work was to evaluate the accuracy of motion correction in both techniques, to identify an optimal rotation correction approach, and determine acquisition strategies for optimal motion correction. It was demonstrated that blades with multiple lines allow more accurate estimation of motion than blades with fewer lines. Also, it was shown that Turboprop MRI is less sensitive to motion than PROPELLER. Furthermore, it was demonstrated that the number of blades does not significantly affect motion correction. Finally, clinically appropriate acquisition strategies that optimize motion correction are discussed for PROPELLER and Turboprop MRI. (c) 2009 Wiley-Liss, Inc.
Vallespir, Gabriel Pizà; Flores, Jesús Burgos; Trigueros, Ignacio Sanpera; Sierra, Eduardo Hevia; Fernández, Pedro Doménech; Olaverri, Juan Carlos Rodríguez; Alonso, Manuel García; Galea, Rafael Ramos; Francisco, Antonio Pérez; Rodríguez de Paz, Beatriz; Carbonell, Pedro Gutiérrez; Thomas, Javier Vicente; López, José Luís González; Paulino, José Ignacio Maruenda; Pitarque, Carlos Barrios; García, Oscar Riquelme
2008-06-15
Prospective multicentric study. To present the preliminary results of an innovative method for standardized correction of scoliosis, vertebral coplanar alignment (VCA), based on a novel concept: the relocation of vertebral axis in a single plane. Normal standing spine has no rotation in coronal or transverse planes, therefore X and Z axis of vertebrae are in the same plane: they are coplanar. VCA intends to relocate these axis in one plane, correcting rotation and translation, while X axis are returned to its normal posterior divergence in sagittal plane in thoracic spine. Twenty-five consecutive adolescent idiopathic scoliosis patients (Lenke type 1) underwent posterior surgery with segmental pedicle screw fixation. Slotted tubes were attached to convex side screws. Two longitudinal rods were inserted through the end of tubes. Then, they were separated along the slots, driving the tubes into one plane, making the axis of the vertebrae coplanar and thus correcting transverse rotation and coronal translation. To obtain kyphosis, distal ends of the tubes were spread in thoracic spine. Correction was maintained by locking a definitive rod in the concave side, then tubes were retrieved and the convex side rod, inserted and tightened. Correction was assessed on preoperative and postoperative full-spine standing radiograph. Vertebral rotation was measured on computed tomography-scan and magnetic resonance imaging. Preoperative average thoracic curves of 61 degrees were corrected to 16 degrees (73%). Preoperative average thoracolumbar curves of 39 degrees were corrected to 12 degrees (70%). Preoperative average thoracic apical rotation of 24 degrees was corrected to 11 degrees (56%). Preoperative average thoracic kyphosis of 18 degrees remained unchanged after surgery; however, no patients had kyphosis <10 degrees after surgery. Rib hump improved from 30 to 11 mm (65%). There were no perioperative complications. VCA provided excellent correction of coronal and transverse planes with normalization of thoracic kyphosis in Lenke type 1 adolescent idiopathic scoliosis surgery.
Inertial Force Coupling to Nonlinear Aeroelasticity of Flexible Wing Aircraft
NASA Technical Reports Server (NTRS)
Nguyen, Nhan T.; Ting, Eric
2016-01-01
This paper investigates the inertial force effect on nonlinear aeroelasticity of flexible wing aircraft. The geometric are nonlinearity due to rotational and tension stiffening. The effect of large bending deflection will also be investigated. Flutter analysis will be conducted for a truss-braced wing aircraft concept with tension stiffening and inertial force coupling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary
Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared headmore » position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS.« less
An assumed-stress hybrid 4-node shell element with drilling degrees of freedom
NASA Technical Reports Server (NTRS)
Aminpour, M. A.
1992-01-01
An assumed-stress hybrid/mixed 4-node quadrilateral shell element is introduced that alleviates most of the deficiencies associated with such elements. The formulation of the element is based on the assumed-stress hybrid/mixed method using the Hellinger-Reissner variational principle. The membrane part of the element has 12 degrees of freedom including rotational or 'drilling' degrees of freedom at the nodes. The bending part of the element also has 12 degrees of freedom. The bending part of the element uses the Reissner-Mindlin plate theory which takes into account the transverse shear contributions. The element formulation is derived from an 8-node isoparametric element by expressing the midside displacement degrees of freedom in terms of displacement and rotational degrees of freedom at corner nodes. The element passes the patch test, is nearly insensitive to mesh distortion, does not 'lock', possesses the desirable invariance properties, has no hidden spurious modes, and for the majority of test cases used in this paper produces more accurate results than the other elements employed herein for comparison.
NASA Astrophysics Data System (ADS)
Jadhav, Shital; Powar, Amit; Patil, Sandip; Supare, Ashish; Farane, Bhagwan; Singh, Rajkumar, Dr.
2017-05-01
The present study was performed to investigate the effect of volume fraction of alpha and transformed beta phase on the high-cycle fatigue (HCF) properties of the bimodal titanium Ti6Al4V alloy. The effect of such morphology on mechanical properties was studied using tensile and rotating bending fatigue test as per ASTM standards. Microstructures and fractography of the specimens were studied using optical and scanning electron microscopy (SEM) respectively.Ti6Al4V alloy samples were heat treated to have three distinctive volume fractions of alpha and transformed beta phase. With an increase in quench delay from 30,50 and 70 sec during quenching after solutionizing temperature of 967°C, the volume fraction of alpha was found to be increased from 20% to 67%. Tests on tensile and rotating bending fatigue showed that the specimen with 20% volume fraction of alpha phase exhibited the highest tensile and fatigue strength, however the properties gets deteriorate with increase in volume fraction of alpha.
NASA Astrophysics Data System (ADS)
Senent, M. L.; Villa, M.; Dominguez-Gomez, R.; Alvarez-Bajo, O.; Carvajal, M.
2011-05-01
Dimethyl ether is a complex interstellar molecule with two internal rotors, which has a high abundance in the star-forming regions. This point, jointed with the recent development of the last-generation observatories operating at the sub-mm and mm wavelengths, has motivated a new laboratory spectral recording in this frequency range. In spite of that, the rotational spectra was only analysed in depth within its vibrational ground state and a new spectral analysis within the fundamental torsional states is in progress. These analysis were carried out with ERHAM, a global model that takes into account the large amplitude motions owing to the two equivalent internal CH3 tops. Nevertheless, their torsional modes in principle interact with the bending COC mode and an appropiate torsional-bending description would be needed in order to analyse the rotational spectra within higher excited states. In this work, a new analysis of the COC bending and the CH3 torsional degrees of freedom has been carried out by means of ab initio calculations. A new and more accurate three-dimensional Potential Energy Surface (PES), is obtained using the CCSD(T) level of theory. This approach has also been applied to other isotopologues of interest, as 13C-dimethyl ether and the monodeuterated species. The purpose of this study is to help in the assignment of new spectral lines of these species and hence to contribute in the spectral cleaning of the astronomical observations to the interstellar medium.
Analysis of Variscan dynamics; early bending of the Cantabria-Asturias Arc, northern Spain
NASA Astrophysics Data System (ADS)
Kollmeier, J. M.; van der Pluijm, B. A.; Van der Voo, R.
2000-08-01
Calcite twinning analysis in the Cantabria-Asturias Arc (CAA) of northern Spain provides a basis for evaluating conditions of Variscan stress and constrains the arc's structural evolution. Twinning typically occurs during earliest layer-parallel shortening, offering the ability to define early conditions of regional stress. Results from the Somiedo-Correcilla region are of two kinds: early maximum compressive stress oriented layer-parallel and at high angles to bedding strike (D1 σ1) and later twin producing compression oriented sub-parallel to strike (D2 σ1). When all D1 compressions are rotated into a uniform east-west reference orientation, a quite linear, north-south trending fold-thrust belt results showing a slight deflection of the southern zone to the south-southeast. North-south-directed D2 σ1 compression was recorded prior to bending of the belt. Calcite twinning data elucidate earliest structural conditions that could not be obtained by other means, whereas the kinematics of arc tightening during D2 is constrained by paleomagnetism. A large and perhaps protracted D2 σ1 is suggested by our results, as manifested by approximately 50% arc tightening prior to acquisition of paleomagnetic remagnetizations throughout the CAA. Early east-west compression (D1 σ1) likely resulted from the Ebro-Aquitaine massif docking to Laurussia whereas the north-directed collision of Africa (D2 σ1) produced clockwise bending in the northern zone, radial folding in the hinge, and rotation of thrusts in the southern zone.
NASA Astrophysics Data System (ADS)
Park, Jung Jin; Na, Suok-Min; Raghunath, Ganesh; Flatau, Alison B.
2016-05-01
Magnetostrictive Fe-Ga and Fe-Al alloys are promising materials for use in bending-mode vibrational energy harvesters. For this study, 50.8 mm × 5.0 mm × 0.5 mm strips of Fe-Ga and Fe-Al were cut from 0.50-mm thick rolled sheet. An atmospheric anneal was used to develop a Goss texture through an abnormal grain growth process. The anneal lead to large (011) grains that covered over 90% of sample surface area. The resulting highly-textured Fe-Ga and Fe-Al strips exhibited saturation magnetostriction values (λsat = λ∥ - λ⊥) of ˜280 ppm and ˜130 ppm, respectively. To maximize 90° rotation of magnetic moments during bending of the strips, we employed compressive stress annealing (SA). Samples were heated to 500°C, and a 100-150 MPa compressive stress was applied while at 500°C for 30 minutes and while being cooled. The effectiveness of the SA on magnetic moment rotation was inferred by comparing post-SA magnetostriction with the maximum possible yield of rotated magnetic moments, which is achieved when λ∥ = λsat and λ⊥ = 0. The uniformity of the SA along the sample length and the impact of the SA on sensing/energy harvesting performance were then assessed by comparing pre- and post-SA bending-stress-induced changes in magnetization at five different locations along the samples. The SA process with a 150 MPa compressive load improved Fe-Ga actuation along the sample length from 170 to 225 ppm (from ˜60% to within ˜80% of λsat). The corresponding sensing/energy harvesting performance improved by as much as a factor of eight in the best sample, however the improvement was not at all uniform along the sample length. The SA process with a 100 MPa compressive load improved Fe-Al actuation along the sample length from 60 to 73 ppm (from ˜46% to ˜56% of λsat, indicating only a marginally effective SA and suggesting the need for modification of the SA protocol. In spite of this, the SA was effective at improving the sensing/energy harvesting performance by a factor of ˜2.5 in the best sample. As with the Fe-Ga strip, improvement in performance was quite varied along the strip length.
Brasil, A V; Coehlo, D G; Filho, T E; Braga, F M
2000-07-01
The authors conducted a biomechanical study in which they compared the uses of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for internal fixation of the cervical spine. An extensive biomechanical evaluation (stiffness in positive and negative rotations around the x, y, and z axes; range of motion in flexion-extension, bilateral axial rotation, and bilateral bending; and neutral zone in flexion-extension, bilateral axial rotation, and lateral bending to the right and to the left) was performed in two groups of intact calf cervical spines. After these initial tests, all specimens were subjected to a distractive flexion Stage 3 ligamentous lesion. Group 1 specimens then underwent surgical fixation by the Rogers technique, and Group 2 specimens underwent surgery by using the Lovely-Carl technique. After fixation, specimens were again submitted to the same biomechanical evaluation. The percentage increase or decrease between the pre- and postoperative parameters was calculated. These values were considered quantitative indicators of the efficacy of the techniques, and the efficacy of the two techniques was compared. Analysis of the findings demonstrated that in the spines treated with the Lovely-Carl technique less restriction of movement was produced without affecting stiffness, compared with those treated with the Rogers technique, thus making the Lovely-Carl technique clinically less useful.
NASA Astrophysics Data System (ADS)
Anderson, David T.; Davis, Scott; Nesbitt, David J.
1996-09-01
High-resolution near infrared spectra of the two ``high'' frequency intermolecular modes of (HF)2 have been characterized in HF-stretch excited states using a slit jet spectrometer. In the spectral region between 4280 and 4480 cm-1, four vibration-rotation-tunneling (VRT) bands are observed and assigned to tunneling pairs of the out-of-plane torsion (ν6) and antigeared bend (ν3) intermolecular modes, in combination with the hydrogen bond donor (ν2) and acceptor (ν1) high-frequency intramolecular HF stretches, respectively. Analysis of the jet-cooled, rotationally resolved spectra provide intermolecular frequencies, rotational constants, tunneling splittings, and predissociation rates for the ν3/ν6 intermolecular excited states. The relatively small changes in the hydrogen bond interconversion tunneling splitting with either ν3 or ν6 excitation indicate that neither intermolecular mode is strongly coupled to the tunneling coordinate. The high-resolution VRT linewidths reveal mode specific predissociation broadening sensitive predominantly to intramolecular excitation, but with significant additional effects due to low-frequency intermolecular excitation as well. The intermolecular vibrational frequencies in the combination states display a systematic dependence on intramolecular redshift that allows all four intermolecular fundamental frequencies to be extrapolated from the near-ir data. Agreement between full 6-D quantum calculations and experiment for the out-of-plane torsion (ν6) vibration is remarkably good (0.5%). However, significant discrepancies (≳10%) between theory and experiment are obtained for the antigeared bend (ν3), indicating the need for further refinement of the HF dimer potential surface. Finally, the observation of all four intermolecular modes allows zero-point contributions to the binding energy to be reliably estimated. The revised value for the binding energy, De=1580(35) cm-1, is slightly higher than semiempirical estimates but now in excellent agreement with recent high level ab initio calculations.
Flutter and oscillating air-force calculations for an airfoil in two-dimensional supersonic flow
NASA Technical Reports Server (NTRS)
Garrick, I E; Rubinow, S I
1946-01-01
A connected account is given of the Possio theory of non-stationary flow for small disturbances in a two-dimensional supersonic flow and of its application to the determination of the aerodynamic forces on an oscillating airfoil. Further application is made to the problem of wing flutter in the degrees of freedom - torsion, bending, and aileron rotations. Numerical tables for flutter calculations are provided for various values of the Mach number greater than unity. Results for bending-torsion wing flutter are shown in figures and are discussed. The static instabilities of divergence and aileron reversal are examined as is a one-degree-of-freedom case of torsional oscillatory instability.
Vibration analysis of rotor blades with an attached concentrated mass
NASA Technical Reports Server (NTRS)
Murthy, V. R.; Barna, P. S.
1977-01-01
The effect of an attached concentrated mass on the dynamics of helicopter rotor blades is determined. The point transmission matrix method was used to define, through three completely automated computer programs, the natural vibrational characteristics (natural frequencies and mode shapes) of rotor blades. The problems of coupled flapwise bending, chordwise bending, and torsional vibration of a twisted nonuniform blade and its special subcase pure torsional vibration are discussed. The orthogonality relations that exist between the natural modes of rotor blades with an attached concentrated mass are derived. The effect of pitch, rotation, and point mass parameters on the collective, cyclic, scissor, and pure torsional modes of a seesaw rotor blade is determined.
Strong Cosserat Elasticity in a Transversely Isotropic Polymer Lattice
NASA Astrophysics Data System (ADS)
Rueger, Z.; Lakes, R. S.
2018-02-01
Large size effects are experimentally measured in lattices of triangular unit cells: about a factor of 36 in torsion rigidity and 29 in bending rigidity. This nonclassical phenomenon is consistent with Cosserat elasticity, which allows for the rotation of points and distributed moments in addition to the translation of points and force stress of classical elasticity. The Cosserat characteristic length for torsion is ℓt=9.4 mm ; for bending, it is ℓb=8.8 mm ; these values are comparable to the cell size. Nonclassical effects are much stronger than in stretch-dominated lattices with uniform straight ribs. The lattice structure provides a path to the attainment of arbitrarily large effects.
Variable percolation threshold of composites with fiber fillers under compression
NASA Astrophysics Data System (ADS)
Lin, Chuan; Wang, Hongtao; Yang, Wei
2010-07-01
The piezoresistant effect in conducting fiber-filled composites has been studied by a continuum percolation model. Simulation was performed by a Monte Carlo method that took into account both the deformation-induced fiber bending and rotation. The percolation threshold was found to rise with the compression strain, which explains the observed positive piezoresistive coefficients in such composites. The simulations unveiled the effect of the microstructure evolution during deformation. The fibers are found to align perpendicularly to the compression direction. As the fiber is bended, the effective length in making a conductive network is shortened. Both effects contribute to a larger percolation threshold and imply a positive piezoresistive coefficient according the universal power law.
Tension and fatigue behavior of 316LVM 1x7 multi-strand cables used as implantable electrodes.
Lewandowski, John J; Varadarajan, Ravikumar; Smith, Brian; Tuma, Chris; Shazly, Mostafa; Vatamanu, Luciano O
2008-07-15
The mechanical behavior of 316LVM 1x7 cables were evaluated in uniaxial tension, and in cyclic strain-controlled fatigue with the use of a Flex tester operated to provide fully reversed bending fatigue. The magnitude of cyclic strains imparted to each cable tested was controlled via the use of different diameter mandrels. Smaller diameter mandrels produced higher values of cyclic strain and lower fatigue life. Multiple samples were tested and analyzed via scanning electron microscopy. The fatigue results were analyzed via a Coffin-Manson-Basquin approach and compared to fatigue data obtained from the literature where testing was conducted on similar materials, but under rotating bending fatigue conditions.
Multi-band asymmetric acoustic transmission in a bended waveguide with multiple mechanisms
NASA Astrophysics Data System (ADS)
Huang, Yu-lei; Sun, Hong-xiang; Xia, Jian-ping; Yuan, Shou-qi; Ding, Xin-lei
2016-07-01
We report the realization of a multi-band device of the asymmetric acoustic transmission by placing a phononic crystal inside a bended waveguide immersed in water, as determined both experimentally and numerically. The asymmetric acoustic transmission exists in three frequency bands below 500 kHz induced by multiple mechanisms. Besides the band gap of the phononic crystal, we also introduce the deaf mode and interaction between the phononic crystal and waveguide. More importantly, this asymmetric transmission can be systematically controlled by mechanically rotating the square rods of the phononic crystal. The device has the advantages of multiple band, broader bandwidth, and adjustable property, showing promising applications in ultrasonic devices.
Spin Rotation of Formalism for Spin Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luccio,A.
The problem of which coefficients are adequate to correctly represent the spin rotation in vector spin tracking for polarized proton and deuteron beams in synchrotrons is here re-examined in the light of recent discussions. The main aim of this note is to show where some previous erroneous results originated and how to code spin rotation in a tracking code. Some analysis of a recent experiment is presented that confirm the correctness of the assumptions.
Rotating stall investigation of 0.72 hub-tip ratio single-stage compressor
NASA Technical Reports Server (NTRS)
Graham, Robert W; Prian, Vasily D
1954-01-01
The rotating stall characteristics of a 0.72 hub-tip ratio, single-stage compressor were investigated. The stage was a 14-inch-diameter replica of the fourth stage of an experimental multistage compressor. No similarity existed between the frequency and propagation rate of the stall patterns observed in the single-stage replica and those observed in the multistage compressor after the fourth stage. A fatigue failure of the rotor blades occurred during the testing which was attributed to a resonance between the stall frequency and the natural bending frequency of the blades.
Influence of Joint Flexibility on Vibration Analysis of Free-Free Beams
NASA Astrophysics Data System (ADS)
Gunda, Jagadish Babu; Krishna, Y.
2014-12-01
In present work, joint flexibility (or looseness) of the free-free beam is investigated by using a two noded beam finite element formulation with transverse displacement and joint rotations as the degrees of freedom per node at joint location. Flexibility of the joint is primarily represented by means of a rotational spring analogy, where the stiffness of the rotational spring characterizes the looseness of the flexible joint for an applied bending moment. Influence of joint location as well as joint stiffness on modal behavior of first five modes of slender, uniform free-free beams are discussed for various values of non-dimensional rotational spring stiffness parameter. Numerical accuracy of the results obtained from the present finite element formulation are validated by using the commercially available finite element software which shows the confidence gained on the numerical results discussed in the present study.
NASA Astrophysics Data System (ADS)
Lai, Changliang; Wang, Junbiao; Liu, Chuang
2014-10-01
Six typical composite grid cylindrical shells are constructed by superimposing three basic types of ribs. Then buckling behavior and structural efficiency of these shells are analyzed under axial compression, pure bending, torsion and transverse bending by finite element (FE) models. The FE models are created by a parametrical FE modeling approach that defines FE models with original natural twisted geometry and orients cross-sections of beam elements exactly. And the approach is parameterized and coded by Patran Command Language (PCL). The demonstrations of FE modeling indicate the program enables efficient generation of FE models and facilitates parametric studies and design of grid shells. Using the program, the effects of helical angles on the buckling behavior of six typical grid cylindrical shells are determined. The results of these studies indicate that the triangle grid and rotated triangle grid cylindrical shell are more efficient than others under axial compression and pure bending, whereas under torsion and transverse bending, the hexagon grid cylindrical shell is most efficient. Additionally, buckling mode shapes are compared and provide an understanding of composite grid cylindrical shells that is useful in preliminary design of such structures.
NASA Astrophysics Data System (ADS)
Pitsevich, G.; Doroshenko, I.; Malevich, A..; Shalamberidze, E.; Sapeshko, V.; Pogorelov, V.; Pettersson, L. G. M.
2017-02-01
Using two sets of effective rotational constants for the ground (000) and the excited bending (010) vibrational states the calculation of frequencies and intensities of vibration-rotational transitions for J″ = 0 - 2; and J‧ = 0 - 3; was carried out in frame of the model of a rigid asymmetric top for temperatures from 0 to 40 K. The calculation of the intensities of vibration-rotational absorption bands of H2O in an Ar matrix was carried out both for thermodynamic equilibrium and for the case of non-equilibrium population of para- and ortho-states. For the analysis of possible interaction of vibration-rotational and translational motions of a water molecule in an Ar matrix by 3D Schrödinger equation solving using discrete variable representation (DVR) method, calculations of translational frequencies of H2O in a cage formed after one argon atom deleting were carried out. The results of theoretical calculations were compared to experimental data taken from literature.
Qu, Z; Kil, J; Xie, F; Garfinkel, A; Weiss, J N
2000-01-01
Scroll wave (vortex) breakup is hypothesized to underlie ventricular fibrillation, the leading cause of sudden cardiac death. We simulated scroll wave behaviors in a three-dimensional cardiac tissue model, using phase I of the Luo-Rudy (LR1) action potential model. The effects of action potential duration (APD) restitution, tissue thickness, filament twist, and fiber rotation were studied. We found that APD restitution is the major determinant of scroll wave behavior and that instabilities arising from APD restitution are the main determinants of scroll wave breakup in this cardiac model. We did not see a "thickness-induced instability" in the LR1 model, but a minimum thickness is required for scroll breakup in the presence of fiber rotation. The major effect of fiber rotation is to maintain twist in a scroll wave, promoting filament bending and thus scroll breakup. In addition, fiber rotation induces curvature in the scroll wave, which weakens conduction and further facilitates wave break. PMID:10827961
Richter, M
2014-08-01
Restoration of a stable and plantigrade foot in deformities of the ankle and/or hindfoot and concomitant degenerative changes at the ankle and subtalar joints. Deformities at the ankle and/or hindfoot and concomitant degenerative changes at the ankle and subtalar joint. Failed (corrective) arthrodesis of the ankle and subtalar joints. Fused ankle and degeneration of the subtalar joint. Failed total ankle replacement with insufficient substance of talar body and/or degeneration of subtalar joint. Massive hindfoot instability. Active local infection or relevant vascular insufficiency, possible preservation of the ankle or subtalar joint (relative contraindication). Prone position and posterolateral approach to ankle and subtalar joints (alternative supine position/anterior approach; lateral position/lateral approach). Exposition of ankle and subtalar joints and removal of remaining cartilage. Optional corrective osteotomies and/or bone grafting. Correction and optional fixation of the corrected position with 2.0 mm K-wires. Mechanically navigated insertion of a retrograde guide wire in projection of the tibial axis and insertion of a second guide wire through the entry point of the nail lateral and dorsal to the tibial axis. Reaming and insertion of the A3 nail with a distal double bend; one posterior and one lateral, and a proximal bend corresponding to a slight recurvatum. Insertion of locking screws into the calcaneus, talus and tibia (twice with optional static or dynamic locking). Optional compression between calcaneus and talus, and between tibia and talus. Insertion of a drainage and layer-wise closure. For the first 6 weeks 15 kg partial weight bearing in an orthosis, followed by full weight bearing in a stable standard shoe. In October 2010 (n = 2) and from 15 October 2011 to 13 April 2012 (n = 26) 28 arthrodeses (with/without correction) with A3 fixation were performed. In all cases, exact nail placement was achieved. Thirteen cases completed follow-up (3-11 months) and showed timely fusion and full mobilization.
Sawicki, Richard H.
1994-01-01
An improved laser correction mirror (10) for correcting aberrations in a laser beam wavefront having a rectangular mirror body (12) with a plurality of legs (14, 16, 18, 20, 22, 24, 26, 28) arranged into opposing pairs (34, 36, 38, 40) along the long sides (30, 32) of the mirror body (12). Vector force pairs (49, 50, 52, 54) are applied by adjustment mechanisms (42, 44, 46, 48) between members of the opposing pairs (34, 36, 38, 40) for bending a reflective surface 13 of the mirror body 12 into a shape defining a function which can be used to correct for comatic aberrations.
Aeroelastic airfoil smart spar
NASA Technical Reports Server (NTRS)
Greenhalgh, Skott; Pastore, Christopher M.; Garfinkle, Moishe
1993-01-01
Aircraft wings and rotor-blades are subject to undesirable bending and twisting excursions that arise from unsteady aerodynamic forces during high speed flight, abrupt maneuvers, or hard landings. These bending excursions can range in amplitude from wing-tip flutter to failure. A continuous-filament construction 'smart' laminated composite box-beam spar is described which corrects itself when subject to undesirable bending excursions or flutter. The load-bearing spar is constructed so that any tendency for the wing or rotor-blade to bend from its normal position is met by opposite twisting of the spar to restore the wing to its normal position. Experimental and theoretical characterization of these spars was made to evaluate the torsion-flexure coupling associated with symmetric lay-ups. The materials used were uniweave AS-4 graphite and a matrix comprised of Shell 8132 resin and U-40 hardener. Experimental tests were conducted on five spars to determine spar twist and bend as a function of load for 0, 17, 30, 45 and 60 deg fiber angle lay-ups. Symmetric fiber lay-ups do exhibit torsion-flexure couplings. Predictions of the twist and bend versus load were made for different fiber orientations in laminated spars using a spline function structural analysis. The analytical results were compared with experimental results for validation. Excellent correlation between experimental and analytical values was found.
Computational Study of Nonequilibrium Chemistry in High Temperature Flows
NASA Astrophysics Data System (ADS)
Doraiswamy, Sriram
Recent experimental measurements in the reflected shock tunnel CUBRC LENS-I facility raise questions about our ability to correctly model the recombination processes in high enthalpy flows. In the carbon dioxide flow, the computed shock standoff distance over the Mars Science Laboratory (MSL) shape was less than half of the experimental result. For the oxygen flows, both pressure and heat transfer data on the double cone geometry were not correctly predicted. The objective of this work is to investigate possible reasons for these discrepancies. This process involves systematically addressing different factors that could possibly explain the differences. These factors include vibrational modeling, role of electronic states and chemistry-vibrational coupling in high enthalpy flows. A state-specific vibrational model for CO2, CO, O2 and O system is devised by taking into account the first few vibrational states of each species. All vibrational states with energies at or below 1 eV are included in the present work. Of the three modes of vibration in CO2 , the antisymmetric mode is considered separately from the symmetric stretching mode and the doubly degenerate bending modes. The symmetric and the bending modes are grouped together since the energy transfer rates between the two modes are very large due to Fermi resonance. The symmetric and bending modes are assumed to be in equilibrium with the translational and rotational modes. The kinetic rates for the vibrational-translation energy exchange reactions, and the intermolecular and intramolecular vibrational-vibrational energy exchange reactions are based on experimental data to the maximum extent possible. Extrapolation methods are employed when necessary. This vibrational model is then coupled with an axisymmetric computational fluid dynamics code to study the expansion of CO2 in a nozzle. The potential role of low lying electronic states is also investigated. Carbon dioxide has a single excited state just below the dissociation limit. CO and O recombine exclusively to this excited state and then relaxes to the ground electronic state. A simple model is proposed to represent the effect of this intermediate state in the recombination process. Preliminary results show that this excited electronic state is a potential reason for increased shock standoff distance observed in LENS facility. The general role of chemistry-vibrational coupling in modeling recombination dominated flows is also investigated. A state-specific model is developed to analyze the complex chemistry-vibration coupling present in high enthalpy nozzle flows. A basic model is formulated assuming molecules are formed at a specific vibrational level and then allowed to relax through a series of vibration-vibration and vibration-translation processes. This is carried out assuming that the molecules behave as either harmonic or anharmonic oscillators. The results are compared with the standard vibration-chemistry model for high enthalpy nozzle flows. Next, a prior recombination model that accounts for the rotational-vibrational coupling is used to obtain prior recombination distribution. A distribution of recombining states is obtained as a function of the total energy available to the system. The results of this model are compared with recent experiments. Additionally, a reduced model is formulated using the concepts of the state-specific model. The results of this reduced model is compared with the state specific model.
Questions Students Ask: Why Not Bend Light with an Electric Field?
ERIC Educational Resources Information Center
Van Heuvelen, Alan
1983-01-01
In response to a question, "Why not use a magnetic or electric field to deflect light?," reviews the relation between electric charge and electric/magnetic fields. Discusses the Faraday effect, (describing matter as an intermediary in the rotation of the place of polarization) and other apparent interactions of light with electric/magnetic fields.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawicki, R.H.; Sweatt, W.
1987-03-03
An apparatus is described for correcting for astigmatism in a light beam reflected off of a light reflecting surface, comprising: (a) a first means defining a flat, rectangular light reflecting surface which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis. The first means is configured so that the light reflecting surface can be adjustably bent into the selected cylindrical curvature by applying a particular bending moment to the first means with respect to the surface, depending upon the curvature desired. The first means includes an integrally formed body member havingmore » a main plate-like segment including a front fact defining the light reflecting surface and a pair of spaced-apart flange segments extending rearwardly of the main segment; and (b) second means acting on the first means for adjustably bending the light reflecting surface into a particular selected one of the different cylindrical curvatures, depending upon the astigmatism to be corrected for.« less
Edinger, Janick; Pai, Dinesh K; Spering, Miriam
2017-01-01
The neural control of pursuit eye movements to visual textures that simultaneously translate and rotate has largely been neglected. Here we propose that pursuit of such targets-texture pursuit-is a fully three-dimensional task that utilizes all three degrees of freedom of the eye, including torsion. Head-fixed healthy human adults (n = 8) tracked a translating and rotating random dot pattern, shown on a computer monitor, with their eyes. Horizontal, vertical, and torsional eye positions were recorded with a head-mounted eye tracker. The torsional component of pursuit is a function of the rotation of the texture, aligned with its visual properties. We observed distinct behaviors between those trials in which stimulus rotation was in the same direction as that of a rolling ball ("natural") in comparison to those with the opposite rotation ("unnatural"): Natural rotation enhanced and unnatural rotation reversed torsional velocity during pursuit, as compared to torsion triggered by a nonrotating random dot pattern. Natural rotation also triggered pursuit with a higher horizontal velocity gain and fewer and smaller corrective saccades. Furthermore, we show that horizontal corrective saccades are synchronized with torsional corrective saccades, indicating temporal coupling of horizontal and torsional saccade control. Pursuit eye movements have a torsional component that depends on the visual stimulus. Horizontal and torsional eye movements are separated in the motor periphery. Our findings suggest that translational and rotational motion signals might be coordinated in descending pursuit pathways.
Multibody dynamic analysis using a rotation-free shell element with corotational frame
NASA Astrophysics Data System (ADS)
Shi, Jiabei; Liu, Zhuyong; Hong, Jiazhen
2018-03-01
Rotation-free shell formulation is a simple and effective method to model a shell with large deformation. Moreover, it can be compatible with the existing theories of finite element method. However, a rotation-free shell is seldom employed in multibody systems. Using a derivative of rigid body motion, an efficient nonlinear shell model is proposed based on the rotation-free shell element and corotational frame. The bending and membrane strains of the shell have been simplified by isolating deformational displacements from the detailed description of rigid body motion. The consistent stiffness matrix can be obtained easily in this form of shell model. To model the multibody system consisting of the presented shells, joint kinematic constraints including translational and rotational constraints are deduced in the context of geometric nonlinear rotation-free element. A simple node-to-surface contact discretization and penalty method are adopted for contacts between shells. A series of analyses for multibody system dynamics are presented to validate the proposed formulation. Furthermore, the deployment of a large scaled solar array is presented to verify the comprehensive performance of the nonlinear shell model.
Basheer Ahamed, Shadir Bughari; Vanajassun, Purushothaman Pranav; Rajkumar, Kothandaraman; Mahalaxmi, Sekar
2018-04-01
Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis. A 3-dimensional model of the simulated root canal with 45° curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 %). The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference. The CTU designed instruments showed the least bending stress on a 45° angulated simulated root canal when compared with all the other tested designs. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Deterministic switching of a magnetoelastic single-domain nano-ellipse using bending
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Cheng-Yen; Sepulveda, Abdon; Keller, Scott
2016-03-21
In this paper, a fully coupled analytical model between elastodynamics with micromagnetics is used to study the switching energies using voltage induced mechanical bending of a magnetoelastic bit. The bit consists of a single domain magnetoelastic nano-ellipse deposited on a thin film piezoelectric thin film (500 nm) attached to a thick substrate (0.5 mm) with patterned electrodes underneath the nano-dot. A voltage applied to the electrodes produces out of plane deformation with bending moments induced in the magnetoelastic bit modifying the magnetic anisotropy. To minimize the energy, two design stages are used. In the first stage, the geometry and bias field (H{submore » b}) of the bit are optimized to minimize the strain energy required to rotate between two stable states. In the second stage, the bit's geometry is fixed, and the electrode position and control mechanism is optimized. The electrical energy input is about 200 (aJ) which is approximately two orders of magnitude lower than spin transfer torque approaches.« less
Stress-strain state of reinforced bimodulus beam on an elastic foundation
NASA Astrophysics Data System (ADS)
Beskopylny, A. N.; Kadomtseva, E. E.; Strelnikov, G. P.; Berdnik, Y. A.
2017-10-01
The paper provides the calculation theory of an arbitrary supported and arbitrary loaded reinforced beam filled with bimodulus material. The formulas determining normal stresses, bending moments, shear forces, rotation angles and a deflection of a rectangular crosssection beam reinforced with any number of bars aligned parallel to the beam axis have been obtained. The numerical study has been carried out to investigate an influence of a modulus of subgrade reaction on values of maximum normal stresses, maximum bending moments and a maximum deflection of a hinged supported beam loaded with a point force or uniform distributed load. The estimation is based on the method of initial parameters for a beam on elastic foundation and the Bubnov-Galerkin method. Values of maximum deflections, maximum bending moments and maximum stresses obtained by these methods coincide. The numerical studies show that taking into consideration the bimodulus of material leads to the necessity to calculate the strength analysis of both tensile stresses and compressive stresses.
Experimental Spin Testing of Integrally Damped Composite Plates
NASA Technical Reports Server (NTRS)
Kosmatka, John
1998-01-01
The experimental behavior of spinning laminated composite pretwisted plates (turbo-fan blade-like) with small (less than 10% by volume) integral viscoelastic damping patches was investigated at NASA-Lewis Research Center. Ten different plate sets were experimentally spin tested and the resulting data was analyzed. The first-four plate sets investigated tailoring patch locations and definitions to damp specific modes on spinning flat graphite/epoxy plates as a function of rotational speed. The remaining six plate sets investigated damping patch size and location on specific modes of pretwisted (30 degrees) graphite/epoxy plates. The results reveal that: (1) significant amount of damping can be added using a small amount of damping material, (2) the damped plates experienced no failures up to the tested 28,000 g's and 750,000 cycles, (3) centrifugal loads caused an increase in bending frequencies and corresponding reductions in bending damping levels that are proportional to the bending stiffness increase, and (4) the centrifugal loads caused a decrease in torsion natural frequency and increase in damping levels of pretwisted composite plates.
Spacetime Non-Commutativity Corrections to the Cardy-Verlinde Formula of Achúcarro-Ortiz Black Hole
NASA Astrophysics Data System (ADS)
Setare, M. R.
2007-02-01
In this letter we compute the corrections to the Cardy-Verlinde formula of Achúcarro-Ortiz black hole, which is the most general two-dimensional black hole derived from the three-dimensional rotating Banados-Teitelboim-Zanelli black hole. These corrections stem from the space non-commutativity. We show that in non-commutative case, non-rotating Achúcarro-Ortiz black hole in contrast with commutative case has two horizons.
Normal functional range of motion of the cervical spine during 15 activities of daily living.
Bible, Jesse E; Biswas, Debdut; Miller, Christopher P; Whang, Peter G; Grauer, Jonathan N
2010-02-01
Prospective clinical study. The purpose of this investigation was to quantify normal cervical range of motion (ROM) and compare these results to those used to perform 15 simulated activities of daily living (ADLs) in asymptomatic subjects. Previous studies looking at cervical ROM during ADLs have been limited and used measuring devices that do not record continuous motion. The purpose of this investigation was to quantify normal cervical ROM and compare these results with those used to perform 15 simulated ADLs in asymptomatic subjects. A noninvasive electrogoniometer and torsiometer were used to measure the ROM of the cervical spine. The accuracy and reliability of the devices were confirmed by comparing the ROM values acquired from dynamic flexion/extension and lateral bending radiographs to those provided by the device, which was activated while the radiographs were obtained. Intraobserver reliability was established by calculating the intraclass correlation coefficient for repeated measurements on the same subjects by 1 investigator on consecutive days. These tools were employed in a clinical laboratory setting to evaluate the full active ROM of the cervical spines (ie, flexion/extension, lateral bending, and axial rotation) of 60 asymptomatic subjects (30 females and 30 males; age, 20 to 75 y) as well as to assess the functional ROM required to complete 15 simulated ADLs. When compared with radiographic measurements, the electrogoniometer was found to be accurate within 2.3+/-2.2 degrees (mean+/-SD) and the intraobserver reliabilities for measuring the full active and functional ROM were both excellent (intraclass correlation coefficient of 0.96 and 0.92, respectively). The absolute ROM and percentage of full active cervical spinal ROM used during the 15 ADLs was 13 to 32 degrees and 15% to 32% (median, 20 degrees/19%) for flexion/extension, 9 to 21 degrees and 11% to 27% (14 degrees/18%) for lateral bending, and 13 to 57 degrees and 12% to 92% (18 degrees/19%) for rotation. Backing up a car required the most ROM of all the ADLs, involving 32% of sagittal, 26% of lateral, and 92% of rotational motion. In general, personal hygiene ADLs such as washing hands and hair, shaving, and applying make-up entailed a significantly greater ROM relative to locomotive ADLs including walking and traveling up and down a set of stairs (P<0.0001); in addition, compared with climbing up these steps, significantly more sagittal and rotational motion was used when descending stairs (P=0.003 and P=0.016, respectively). When picking up an object from the ground, a squatting technique required a lower percentage of lateral and rotational ROM than bending at the waist (P=0.002 and P<0.0001). By quantifying the amounts of cervical motion required to execute a series of simulated ADLs, this study indicates that most individuals use a relatively small percentage of their full active ROM when performing such activities. These findings provide baseline data which may allow clinicians to accurately assess preoperative impairment and postsurgical outcomes.
Coupling between shear and bending in the analysis of beam problems: Planar case
NASA Astrophysics Data System (ADS)
Shabana, Ahmed A.; Patel, Mohil
2018-04-01
The interpretation of invariants, such as curvatures which uniquely define the bending and twist of space curves and surfaces, is fundamental in the formulation of the beam and plate elastic forces. Accurate representations of curve and surface invariants, which enter into the definition of the strain energy equations, is particularly important in the case of large displacement analysis. This paper discusses this important subject in view of the fact that shear and bending are independent modes of deformation and do not have kinematic coupling; this is despite the fact that kinetic coupling may exist. The paper shows, using simple examples, that shear without bending and bending without shear at an arbitrary point and along a certain direction are scenarios that higher-order finite elements (FE) can represent with a degree of accuracy that depends on the order of interpolation and/or mesh size. The FE representation of these two kinematically uncoupled modes of deformation is evaluated in order to examine the effect of the order of the polynomial interpolation on the accuracy of representing these two independent modes. It is also shown in this paper that not all the curvature vectors contribute to bending deformation. In view of the conclusions drawn from the analysis of simple beam problems, the material curvature used in several previous investigations is evaluated both analytically and numerically. The problems associated with the material curvature matrix, obtained using the rotation of the beam cross-section, and the fundamental differences between this material curvature matrix and the Serret-Frenet curvature matrix are discussed.
NASA Astrophysics Data System (ADS)
Ferasat, Keyvan; Aashuri, Hossein; Kokabi, Amir Hossein; Shafizadeh, Mahdi; Nikzad, Siamak
2015-12-01
Semisolid stir joining has been under deliberation as a possible method for joining of copper alloys. In this study, the effect of temperature and rotational speed of stirrer on macrostructure evaluation and mechanical properties of samples were investigated. Optical microscopy and X-ray diffraction were performed for macro and microstructural analysis. A uniform micro-hardness profile was attained by semisolid stir joining method. The ultimate shear strength and bending strength of welded samples were improved in comparison with the cast sample. There is also lower area porosity in welded samples than the cast metal. The mechanical properties were improved by increasing temperature and rotational speed of the joining process.
In-beam spectroscopic study of 244Cf
NASA Astrophysics Data System (ADS)
Konki, J.; Sulignano, B.; Greenlees, P. T.; Theisen, Ch.; Auranen, K.; Badran, H.; Briselet, R.; Cox, D. M.; Defranchi Bisso, F.; Dobaczewski, J.; Grahn, T.; Herzán, A.; Herzberg, R.-D.; Julin, R.; Juutinen, S.; Khuyagbaatar, J.; Leino, M.; Lightfoot, A.; Pakarinen, J.; Papadakis, P.; Partanen, J.; Rahkila, P.; Sandzelius, M.; Sarén, J.; Scholey, C.; Shi, Y.; Smolen, M.; Sorri, J.; Stolze, S.; Uusitalo, J.
2018-02-01
The ground-state rotational band of the neutron-deficient californium (Z =98 ) isotope 244Cf was identified for the first time and measured up to a tentative spin and parity of Iπ=20+ . The observation of the rotational band indicates that the nucleus is deformed. The kinematic and dynamic moments of inertia were deduced from the measured γ -ray transition energies. The behavior of the dynamic moment of inertia revealed an up-bend due to a possible alignment of coupled nucleons in high-j orbitals starting at a rotational frequency of about ℏ ω =0.20 MeV . The results were compared with the systematic behavior of the even-even N =146 isotones as well as with available theoretical calculations that have been performed for nuclei in the region.
Far-infrared laser magnetic resonance of vibrationally excited CD2
NASA Technical Reports Server (NTRS)
Evenson, K. M.; Sears, T. J.; Mckellar, A. R. W.
1984-01-01
The detection of 13 rotational transitions in the first excited bending state (010) of CD2 using the technique of far-infrared laser magnetic resonance spectroscopy is reported. Molecular parameters for this state are determined from these new data together with existing infrared observations of the v(2) band. Additional information on the ground vibrational state (000) is also provided by the observation of a new rotational transition, and this is combined with existing data to provide a refined set of molecular parameters for the CD2 ground state. One spectrum has been observed that is assigned as a rotational transition within the first excited symmetric stretching state (100) of CD2. These data will be of use in refining the structure and the potential function of the methylene radical.
Electron beam machining using rotating and shaped beam power distribution
Elmer, John W.; O'Brien, Dennis W.
1996-01-01
An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.
The different baryonic Tully-Fisher relations at low masses.
Brook, Chris B; Santos-Santos, Isabel; Stinson, Greg
2016-06-11
We compare the Baryonic Tully-Fisher relation (BTFR) of simulations and observations of galaxies ranging from dwarfs to spirals, using various measures of rotational velocity V rot . We explore the BTFR when measuring V rot at the flat part of the rotation curve, V flat , at the extent of H i gas, V last , and using 20 per cent ( W 20 ) and 50 per cent ( W 50 ) of the width of H i line profiles. We also compare with the maximum circular velocity of the parent halo, [Formula: see text], within dark matter only simulations. The different BTFRs increasingly diverge as galaxy mass decreases. Using V last one obtains a power law over four orders of magnitude in baryonic mass, with slope similar to the observed BTFR. Measuring V flat gives similar results as V last when galaxies with rising rotation curves are excluded. However, higher rotation velocities would be found for low-mass galaxies if the cold gas extended far enough for V rot to reach a maximum. W 20 gives a similar slope as V last but with slightly lower values of V rot for low-mass galaxies, although this may depend on the extent of the gas in your galaxy sample. W 50 bends away from these other relations towards low velocities at low masses. By contrast, [Formula: see text] bends towards high velocities for low-mass galaxies, as cold gas does not extend out to the radius at which haloes reach [Formula: see text]. Our study highlights the need for careful comparisons between observations and models: one needs to be consistent about the particular method of measuring V rot , and precise about the radius at which velocities are measured.
NASA Astrophysics Data System (ADS)
Li, Zhenyu; Ding, Lin; Lippert, Peter C.; Wei, Honghong
2013-09-01
Thick Cenozoic marine and terrestrial sediments are widely distributed along the perimeter of the Pamir plateau and provide valuable information on the kinematic evolution of the region. Here, we report new biostratigraphic and paleomagnetic results from the piedmont of the Western Kunlun Shan to constrain the magnitude and timing of vertical-axis rotations along the eastern margin of the Pamir. Sampling sites were selected by rock formations and ages, which are based on previous field mapping and on litholostratigraphic and biostratigraphic work presented here. Thermomagnetic analysis, step-wise thermal demagnetization behavior, and positive field tests all suggest that the characteristic remanent magnetization (ChRM) directions most probably have a primary detrital and chemical origin. Our results indicate variable, minor, but in some intervals significant vertical axis rotations with respect to a stable Asian reference frame. This pattern of rotations is similar to paleomagnetic data reported in previously published studies from the Eastern Pamir foreland. In contrast, published paleomagnetic data from the Western Pamir foreland consistently indicate significant CCW rotations within that region. Collectively, these results challenge simple oroclinal bending models for the origin of the Pamir salient, and instead are more consistent with an asymmetric "half-orocline" kinematic model in which the curvature of the Western Pamir is the product of a combination of lithospheric bending of an originally quasi-linear mountain belt and radial thrusting, and the subdued curvature of the eastern edge of the plateau is the result of lateral translation of the Pamir plateau northward past Tibet and Tarim along the Kashgar-Yecheng transfer system. Our results are consistent with activity on the Kashgar-Yecheng transfer system in the Early Miocene.
A coupled Eulerian/Lagrangian method for the solution of three-dimensional vortical flows
NASA Technical Reports Server (NTRS)
Felici, Helene Marie
1992-01-01
A coupled Eulerian/Lagrangian method is presented for the reduction of numerical diffusion observed in solutions of three-dimensional rotational flows using standard Eulerian finite-volume time-marching procedures. A Lagrangian particle tracking method using particle markers is added to the Eulerian time-marching procedure and provides a correction of the Eulerian solution. In turn, the Eulerian solutions is used to integrate the Lagrangian state-vector along the particles trajectories. The Lagrangian correction technique does not require any a-priori information on the structure or position of the vortical regions. While the Eulerian solution ensures the conservation of mass and sets the pressure field, the particle markers, used as 'accuracy boosters,' take advantage of the accurate convection description of the Lagrangian solution and enhance the vorticity and entropy capturing capabilities of standard Eulerian finite-volume methods. The combined solution procedures is tested in several applications. The convection of a Lamb vortex in a straight channel is used as an unsteady compressible flow preservation test case. The other test cases concern steady incompressible flow calculations and include the preservation of turbulent inlet velocity profile, the swirling flow in a pipe, and the constant stagnation pressure flow and secondary flow calculations in bends. The last application deals with the external flow past a wing with emphasis on the trailing vortex solution. The improvement due to the addition of the Lagrangian correction technique is measured by comparison with analytical solutions when available or with Eulerian solutions on finer grids. The use of the combined Eulerian/Lagrangian scheme results in substantially lower grid resolution requirements than the standard Eulerian scheme for a given solution accuracy.
A new dynamic model of rotor-blade systems
NASA Astrophysics Data System (ADS)
Ma, Hui; Lu, Yang; Wu, Zhiyuan; Tai, Xingyu; Li, Hui; Wen, Bangchun
2015-11-01
A new dynamic model of rotor-blade systems is developed in this paper considering the lateral and torsional deformations of the shaft, gyroscopic effects of the rotor which consists of shaft and disk, and the centrifugal stiffening, spin softening and Coriolis force of the blades. In this model, the rotating flexible blades are represented by Timoshenko beams. The shaft and rigid disk are described by multiple lumped mass points (LMPs), and these points are connected by massless springs which have both lateral and torsional stiffness. LMPs are represented by the corresponding masses and mass moments of inertia in lateral and rotational directions, where each point has five degrees of freedom (dofs) excluding axial dof. Equations of motion of the rotor-blade system are derived using Hamilton's principle in conjunction with the assumed modes method to describe blade deformation. The proposed model is compared with both finite element (FE) model and real experiments. The proposed model is first validated by comparing the model natural frequencies and vibration responses with those obtained from an FE model. A further verification of the model is then performed by comparing the model natural frequencies at zero rotational speed with those obtained from experimental studies. The results shown a good agreement between the model predicted system characteristics and those obtained from the FE model and experimental tests. Moreover, the following interesting phenomena have been revealed from the new model based analysis: The torsional natural frequency of the system decreases with the increase of rotational speed, and the frequency veering phenomenon has been observed at high rotational speed; The complicated coupling modes, such as the blade-blade coupling mode (BB), the coupling mode between the rotor lateral vibration and blade bending (RBL), and the coupling mode between the rotor torsional vibration and blade bending (RBT), have also been observed when the number of blades increases.
Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.
Lee, Hyung-Chul; Jung, Chul-Woo; Kim, Hee Chan
2017-01-01
The discrepancy between spatial orientations of an endoscopic image and a physician's working environment can make it difficult to interpret endoscopic images. In this study, we developed and evaluated a device that corrects the endoscopic image orientation using an accelerometer and gyrosensor. The acceleration of gravity and angular velocity were retrieved from the accelerometer and gyrosensor attached to the handle of the endoscope. The rotational angle of the endoscope handle was calculated using a Kalman filter with transmission delay compensation. Technical evaluation of the orientation correction system was performed using a camera by comparing the optical rotational angle from the captured image with the rotational angle calculated from the sensor outputs. For the clinical utility test, fifteen anesthesiology residents performed a video endoscopic examination of an airway model with and without using the orientation correction system. The participants reported numbers written on papers placed at the left main, right main, and right upper bronchi of the airway model. The correctness and the total time it took participants to report the numbers were recorded. During the technical evaluation, errors in the calculated rotational angle were less than 5 degrees. In the clinical utility test, there was a significant time reduction when using the orientation correction system compared with not using the system (median, 52 vs. 76 seconds; P = .012). In this study, we developed a real-time endoscopic image orientation correction system, which significantly improved physician performance during a video endoscopic exam.
Wireless prototype based on pressure and bending sensors for measuring gait [corrected] quality.
Grenez, Florent; Viqueira Villarejo, María; García Zapirain, Begoña; Méndez Zorrilla, Amaia
2013-07-29
This paper presents a technological solution based on sensors controlled remotely in order to monitor, track and evaluate the gait quality in people with or without associated pathology. Special hardware simulating a shoe was developed, which consists of three pressure sensors, two bending sensors, an Arduino mini and a Bluetooth module. The obtained signals are digitally processed, calculating the standard deviation and establishing thresholds obtained empirically. A group of users was chosen with the aim of executing two modalities: natural walking and dragging the left foot. The gait was parameterized with the following variables: as far as pressure sensors are concerned, one pressure sensor under the first metatarsal (right sensor), another one under the fifth metatarsal (left) and a third one under the heel were placed. With respect to bending sensors, one bending sensor was placed for the ankle movement and another one for the foot sole. The obtained results show a rate accuracy oscillating between 85% (right sensor) and 100% (heel and bending sensors). Therefore, the developed prototype is able to differentiate between healthy gait and pathological gait, and it will be used as the base of a more complex and integral technological solution, which is being developed currently.
Effect of train carbody's parameters on vertical bending stiffness performance
NASA Astrophysics Data System (ADS)
Yang, Guangwu; Wang, Changke; Xiang, Futeng; Xiao, Shoune
2016-10-01
Finite element analysis(FEA) and modal test are main methods to give the first-order vertical bending vibration frequency of train carbody at present, but they are inefficiency and waste plenty of time. Based on Timoshenko beam theory, the bending deformation, moment of inertia and shear deformation are considered. Carbody is divided into some parts with the same length, and it's stiffness is calculated with series principle, it's cross section area, moment of inertia and shear shape coefficient is equivalent by segment length, and the fimal corrected first-order vertical bending vibration frequency analytical formula is deduced. There are 6 simple carbodies and 1 real carbody as examples to test the formula, all analysis frequencies are very close to their FEA frequencies, and especially for the real carbody, the error between analysis and experiment frequency is 0.75%. Based on the analytic formula, sensitivity analysis of the real carbody's design parameters is done, and some main parameters are found. The series principle of carbody stiffness is introduced into Timoshenko beam theory to deduce a formula, which can estimate the first-order vertical bending vibration frequency of carbody quickly without traditional FEA method and provide a reference to design engineers.
The femoral neck-shaft angle on plain radiographs: a systematic review.
Boese, Christoph Kolja; Dargel, Jens; Oppermann, Johannes; Eysel, Peer; Scheyerer, Max Joseph; Bredow, Jan; Lechler, Philipp
2016-01-01
The femoral neck-shaft angle (NSA) is an important measure for the assessment of the anatomy of the hip and planning of operations. Despite its common use, there remains disagreement concerning the method of measurement and the correction of hip rotation and femoral version of the projected NSA on conventional radiographs. We addressed the following questions: (1) What are the reported values for NSA in normal adult subjects and in osteoarthritis? (2) Is there a difference between non-corrected and rotation-corrected measurements? (3) Which methods are used for measuring the NSA on plain radiographs? (4) What could be learned from an analysis of the intra- and interobserver reliability? A systematic literature search was performed including 26 publications reporting the measurement of the NSA on conventional radiographs. The mean NSA of healthy adults (5,089 hips) was 128.8° (98-180°) and 131.5° (115-155°) in patients with osteoarthritis (1230 hips). The mean NSA was 128.5° (127-130.5°) for the rotation-corrected and 129.5° (119.6-151°) for the non-corrected measurements. Our data showed a high variance of the reported neck-shaft angles. Notably, we identified the inconsistency of the published methods of measurement as a central issue. The reported effect of rotation-correction cannot be reliably verified.
Viljoen, Stephanus V; DeVries Watson, Nicole A; Grosland, Nicole M; Torner, James; Dalm, Brian; Hitchon, Patrick W
2014-10-01
The objective of this study was to evaluate the biomechanical properties of lateral instrumentation compared with short- and long-segment pedicle screw constructs following an L-1 corpectomy and reconstruction with an expandable cage. Eight human cadaveric T10-L4 spines underwent an L-1 corpectomy followed by placement of an expandable cage. The spines then underwent placement of lateral instrumentation consisting of 4 monoaxial screws and 2 rods with 2 cross-connectors, short-segment pedicle screw fixation involving 1 level above and below the corpectomy, and long-segment pedicle screw fixation (2 levels above and below). The order of instrumentation was randomized in the 8 specimens. Testing was conducted for each fixation technique. The spines were tested with a pure moment of 6 Nm in all 6 degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In flexion, extension, and left/right lateral bending, posterior long-segment instrumentation had significantly less motion compared with the intact state. Additionally, posterior long-segment instrumentation was significantly more rigid than short-segment and lateral instrumentation in flexion, extension, and left/right lateral bending. In axial rotation, the posterior long-segment construct as well as lateral instrumentation were not significantly more rigid than the intact state. The posterior long-segment construct was the most rigid in all 6 degrees of freedom. In the setting of highly unstable fractures requiring anterior reconstruction, and involving all 3 columns, long-segment posterior pedicle screw constructs are the most rigid.
Electric-field effects in the twist-bend nematic phase
NASA Astrophysics Data System (ADS)
Meyer, Claire; Dozov, Ivan; Davidson, Patrick; Luckhurst, Geoffrey R.; Dokli, Irena; Knezevic, Anamarija; Lesac, Andreja
2018-02-01
In the recently discovered Twist-Bend Nematic (NTB) phase, the nematic director is spontaneously distorted and twisted along a conical helix with an extremely short pitch, 10 nm. We have investigated the behavior of the NTB phase subject to an electric-field. We show that, due to the periodic NTB structure, the electro-optic effects are not nematic-like but are close analogs to those in the smectic and cholesteric phases. In particular, we have studied the fast (sub-microsecond) flexoelectrically-induced rotation of the optic axis, which is similar to the electroclinic effect in the SmA* phase and the flexoelectric response of short-pitch cholesterics. We discuss the possible applications of the fast NTB electro-optic effects.
Load attenuating passively adaptive wind turbine blade
Veers, Paul S.; Lobitz, Donald W.
2003-01-07
A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.
Load attenuating passively adaptive wind turbine blade
Veers, Paul S.; Lobitz, Donald W.
2003-01-01
A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.
Rotational Diffusion Depends on Box Size in Molecular Dynamics Simulations.
Linke, Max; Köfinger, Jürgen; Hummer, Gerhard
2018-06-07
We show that the rotational dynamics of proteins and nucleic acids determined from molecular dynamics simulations under periodic boundary conditions suffer from significant finite-size effects. We remove the box-size dependence of the rotational diffusion coefficients by adding a hydrodynamic correction k B T/6 ηV with k B Boltzmann's constant, T the absolute temperature, η the solvent shear viscosity, and V the box volume. We show that this correction accounts for the finite-size dependence of the rotational diffusion coefficients of horse-heart myoglobin and a B-DNA dodecamer in aqueous solution. The resulting hydrodynamic radii are in excellent agreement with experiment.
Rotation of lathe-cut hydrogel lenses on the eye.
Harris, M G; Harris, K L; Ruddell, D
1976-01-01
The rotation lathe-cut HydroCurveTM gel contact lens was measured on six eyes to evaluate the parameters that influence lens rotation and to determine if this lens could be used to correct astigmatism. Of the 72 observations made, 73.6% showed some lens rotation, and 33.4% of the sample rotated more than 5 degrees per 10 blinks. Of the observations in which rotation was noted, 88.7% were encyclorotation. These results are similar to those found for spin-cast hydrogel lenses. None of the lens parameters evaluated seemed to be related to lens rotation, whereas the eye parameters studied were. Lenses were more likely to rotate on eyes with smaller corneal diameters, smaller palpebral apertures, and corneal curvatures steeper than 4 3.00 DK (X2, N =72, p less than 0.05). Our findings indicate that some method of lens stabilization will be needed before lathe-cut hydrogel lenses can be used to effectively correct astigmatism.
SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenton, O; Valdes, G; Yin, L
Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. Themore » calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.« less
Self-gravitational instability of dense degenerate viscous anisotropic plasma with rotation
NASA Astrophysics Data System (ADS)
Sharma, Prerana; Patidar, Archana
2017-12-01
The influence of finite Larmor radius correction, tensor viscosity and uniform rotation on self-gravitational and firehose instabilities is discussed in the framework of the quantum magnetohydrodynamic and Chew-Goldberger-Low (CGL) fluid models. The general dispersion relation is obtained for transverse and longitudinal modes of propagation. In both the modes of propagation the dispersion relation is further analysed with respect to the direction of the rotational axis. In the analytical discussion the axis of rotation is considered in parallel and in the perpendicular direction to the magnetic field. (i) In the transverse mode of propagation, when rotation is parallel to the direction of the magnetic field, the Jeans instability criterion is affected by the rotation, finite Larmor radius (FLR) and quantum parameter but remains unaffected due to the presence of tensor viscosity. The calculated critical Jeans masses for rotating and non-rotating dense degenerate plasma systems are \\odot $ and \\odot $ respectively. It is clear that the presence of rotation enhances the threshold mass of the considered system. (ii) In the case of longitudinal mode of propagation when rotation is parallel to the direction of the magnetic field, Alfvén and viscous self-gravitating modes are obtained. The Alfvén mode is modified by FLR corrections and rotation. The analytical as well as graphical results show that the presence of FLR and rotation play significant roles in stabilizing the growth rate of the firehose instability by suppressing the parallel anisotropic pressure. The viscous self-gravitating mode is significantly affected by tensor viscosity, anisotropic pressure and the quantum parameter while it remains free from rotation and FLR corrections. When the direction of rotation is perpendicular to the magnetic field, the rotation of the considered system coupled the Alfvén and viscous self-gravitating modes to each other. The finding of the present work is applicable to strongly magnetized dense degenerate plasma.
Bösch, Nadja; Hofstetter, Martin; Bürki, Alexander; Vidondo, Beatriz; Davies, Fenella; Forterre, Franck
2017-11-01
Objective To study the biomechanical effect of facetectomy in 10 large breed dogs (>24 kg body weight) on the fourth canine cervical functional spinal unit. Methods Canine cervical spines were freed from all muscles. Spines were mounted on a six-degrees-of-freedom spine testing machine for three-dimensional motion analysis. Data were recorded with an optoelectronic motion analysis system. The range of motion was determined in all three primary motions as well as range of motion of coupled motions on the intact specimen, after unilateral and after bilateral facetectomy. Repeated-measures analysis of variance models were used to assess the changes of the biomechanical properties in the three treatment groups considered. Results Facetectomy increased range of motion of primary motions in all directions. Axial rotation was significantly influenced by facetectomy. Coupled motion was not influenced by facetectomy except for lateral bending with coupled motion axial rotation. The coupling factor (coupled motion/primary motion) decreased after facetectomy. Symmetry of motion was influenced by facetectomy in flexion-extension and axial rotation, but not in lateral bending. Clinical Significance Facet joints play a significant role in the stability of the cervical spine and act to maintain spatial integrity. Therefore, cervical spinal treatments requiring a facetectomy should be carefully planned and if an excessive increase in range of motion is expected, complications should be anticipated and reduced via spinal stabilization. Schattauer GmbH Stuttgart.
Wang, Kesai; Taylor, John-Stephen A
2017-07-07
Cyclobutane pyrimidine dimers (CPDs) are DNA photoproducts linked to skin cancer, whose mutagenicity depends in part on their frequency of formation and deamination. Nucleosomes modulate CPD formation, favoring outside facing sites and disfavoring inward facing sites. A similar pattern of CPD formation in protein-free DNA loops suggests that DNA bending causes the modulation in nucleosomes. To systematically study the cause and effect of nucleosome structure on CPD formation and deamination, we have developed a circular permutation synthesis strategy for positioning a target sequence at different superhelix locations (SHLs) across a nucleosome in which the DNA has been rotationally phased with respect to the histone octamer by TG motifs. We have used this system to show that the nucleosome dramatically modulates CPD formation in a T11-tract that covers one full turn of the nucleosome helix at seven different SHLs, and that the position of maximum CPD formation at all locations is shifted to the 5΄-side of that found in mixed-sequence nucleosomes. We also show that an 80-mer minicircle DNA using the same TG-motifs faithfully reproduces the CPD pattern in the nucleosome, indicating that it is a good model for protein-free rotationally phased bent DNA of the same curvature as in a nucleosome, and that bending is modulating CPD formation. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
Anomalous Centrifugal Distortion in NH_2
NASA Astrophysics Data System (ADS)
Martin-Drumel, Marie-Aline; Pirali, Olivier; Coudert, L. H.
2017-06-01
The NH2 radical spectrum, first observed by Herzberg and Ramsay, is dominated by a strong Renner-Teller effect giving rise to two electronic states: the bent X ^{2}B_1 ground state and the quasi-linear A ^{2}A_1 excited state. The NH2 radical has been the subject of numerous high-resolution investigations and its electronic and ro-vibrational transitions have been measured. Using synchrotron radiation, new rotational transitions have been recently recorded and a value of the rotational quantum number N as large as 26 could be reached. In the X ^{2}B_1 ground state, the NH2 radical behaves like a triatomic molecule displaying spin-rotation splittings. Due to the lightness of the molecule, a strong coupling between the overall rotation and the bending mode arises whose effects increase with N and lead to the anomalous centrifugal distortion evidenced in the new measurements.^d In this talk the Bending-Rotation approach developed to account for the anomalous centrifugal distortion of the water molecule is modified to include spin-rotation coupling and applied to the fitting of high-resolution data pertaining to the ground electronic state of NH2. A preliminary line position analysis of the available data^{c,d} allowed us to account for 1681 transitions with a unitless standard deviation of 1.2. New transitions could also be assigned in the spectrum recorded by Martin-Drumel et al.^d In the talk, the results obtained with the new theoretical approach will be compared to those retrieved with a Watson-type Hamiltonian and the effects of the vibronic coupling between the ground X ^{2}B_1 and the excited A ^{2}A_1 electronic state will be discussed. Herzberg and Ramsay, J. Chem. Phys. 20 (1952) 347 Dressler and Ramsay, Phil. Trans. R. Soc. A 25 (1959) 553 Hadj Bachir, Huet, Destombes, and Vervloet, J. Molec. Spectrosc. 193 (1999) 326 McKellar, Vervloet, Burkholder, and Howard, J. Molec. Spectrosc. 142 (1990) 319 Morino and Kawaguchi, J. Molec. Spectrosc. 182 (1997) 428 Martin-Drumel, Pirali, and Vervloet, J. Phys. Chem. A 118 (2014) 1331 Coudert, J. Molec. Spectrosc. 165 (1994) 406
Dynamics of small flexible fibers in turbulent channel flow
NASA Astrophysics Data System (ADS)
Marchioli, Cristian; Dotto, Diego; Soldati, Alfredo
2017-11-01
In this paper we investigate the dynamics of small flexible fibers in turbulent channel flow. Our aim is to examine the effect of local shear and turbulence anisotropy on the translation and rotation of fibers with different elongation and inertia. To these aims, we use a Eulerian-Lagrangian approach based on direct numerical simulation of turbulence in the dilute regime, and we model fibers, which are longer than the Kolmogorov scale, as chains of sub-Kolmogorov rods connected through ball-and-socket joints that enable bending and twisting. Velocity, orientation and concentration statistics, extracted from simulations at Reτ = 300 , are presented to give insights into the complex fibers-turbulence interactions that arise when non-sphericity and deformability add to inertial bias. Compared to fibers that translate and rotate as rigid bodies relative to the surrounding fluid, flexible fibers exhibit a stronger tendency to accumulate in the near-wall region, where they are trapped by the same mechanisms that govern preferential concentration of spherical particles. In such region, the mean shear is strong enough to reduce bending and stretch the fibers. Preferential segregation into low-speed streaks and preferential orientation in the mean flow direction are also observed.
Endoscopic neurosurgery "around the corner" with a rigid endoscope. Technical note.
Hopf, N J
1999-03-01
Endoscopically "working around the corner" is presently restricted to the use of flexible endoscopes or an endoscope-assisted microneurosurgical (EAM) technique. In order to overcome the limitations of these solutions, endoscopic equipment and techniques were developed for "working around the corner" with rigid endoscopes. A steering insert with a 5 French working channel is capable of steering instruments around the corner by actively bending the guiding track and consecutively the instrument. A special fixation device enables strict axial rotation of the endoscope in the operating field. Endoscopic procedures "around the corner", including aqueductal stenting, pellucidotomy, third ventriculostomy and biopsy were performed in human cadavers. Special features of the used pediatric neuroendoscope system, i.e., reliable fixation, axial rotation, and controlled steering of instruments, increase the safety and reduce the surgical traumatization in selected cases, such as obstructive hydrocephalus due to a mass lesion in the posterior third ventricle, since endoscopic third ventriculostomy and biopsy can be performed through the same burr hole trephination. Limitations of this technique are given by the size of the foramen of Monro and the height of the third ventricle as well as by the bending angle of the instruments (40-50 degrees).
Standing wave brass-PZT square tubular ultrasonic motor.
Park, Soonho; He, Siyuan
2012-09-01
This paper reports a standing wave brass-PZT tubular ultrasonic motor. The motor is composed of a brass square tube with two teeth on each tube end. Four PZT plates are attached to the outside walls of the brass tube. The motor requires only one driving signal to excite vibration in a single bending mode to generate reciprocating diagonal trajectories of teeth on the brass tube ends, which drive the motor to rotate. Bi-directional rotation is achieved by exciting different pairs of PZT plates to switch the bending vibration direction. Through using the brass-PZT tube structure, the motor can take high magnitude vibration to achieve a high output power in comparison to PZT tube based ultrasonic motors. Prototypes are fabricated and tested. The dimension of the brass-PZT tube is 3.975mm×3.975mm×16mm. Measured performance is a no-load speed of >1000RPM, a stall torque of 370μNm and a maximum output power of 16 mW when a sinusoidal driving voltage of 50V is applied. The working frequencies of the motor are 46,050Hz (clockwise) and 46,200Hz (counter-clockwise). Copyright © 2012. Published by Elsevier B.V.
Characteristics of Reduction Gear in Electric Agricultural Vehicle
NASA Astrophysics Data System (ADS)
Choi, W. S.; Pratama, P. S.; Supeno, D.; Jeong, S. W.; Byun, J. Y.; Woo, J. H.; Lee, E. S.; Park, C. S.
2018-03-01
In electric agricultural machine a reduction gear is needed to convert the high speed rotation motion generated by DC motor to lower speed rotation motion used by the vehicle. The reduction gear consists of several spur gears. Spur gears are the most easily visualized gears that transmit motion between two parallel shafts and easy to produce. The modelling and simulation of spur gears in DC motor reduction gear is important to predict the actual motion behaviour. A pair of spur gear tooth in action is generally subjected to two types of cyclic stress: contact stress and bending stress. The stress may not attain their maximum values at the same point of contact fatigue. These types of failure can be minimized by analysis of the problem during the design stage and creating proper tooth surface profile with proper manufacturing methods. To improve its life expectation in this study modal and stress analysis of reduction gear is simulated using ANSYS workbench based on finite element method (FEM). The modal analysis was done to understand reduction gear deformation behaviour when vibration occurs. FEM static stress analysis is also simulated on reduction gear to simulate the gear teeth bending stress and contact stress behaviour.
NASA Astrophysics Data System (ADS)
Kolosov, Vladimir Yu.
2011-03-01
Uunusual transrotational structure is presented for crystal growth in thin amorphous films. Experimental results have been obtained for the microcrystals of different chemical nature (oxides, chalcogenides, metals and alloys) grown in thin films prepared by various methods. Basically we used transmission electron microscopy (TEM): our original bend contour technique combined with selected area diffraction (HREM, EDX and CBED used in due cases as well as AFM). The unusual phenomenon (also traced inside TEM in situ) resides in strong (up to the whole rotation per micrometer) regular internal bending of crystal lattice planes (transrotation) in a growing crystal. As a result permanent rotation of the lattice orientation (realized round an axis lying in the film plane) is revealed by TEM. Different geometries of transrotational nanostructures are described: cylindrical, ellipsoidal, etc. Such crystal with transrotational atom periodicity resembles ideal single crystal enclosed in a curved space. Transrotational crystals can be considered as endless 2.5 D analogy of nanotubes, nanonions. Transrotation is strongly increasing as the film gets thinner in the range 100-15 nm. Transrotations supplement well known dislocations (in crystals) and disclinations (in liquid crystals). Support of RF Ministry of Education and Science is acknowledged.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smitsmans, Monique H.P.; Bois, Josien de; Sonke, Jan-Jakob
Purpose: The objectives of this study were to quantify residual interfraction displacement of seminal vesicles (SV) and investigate the efficacy of rotation correction on SV displacement in marker-based prostate image-guided radiotherapy (IGRT). We also determined the effect of marker registration on the measured SV displacement and its impact on margin design. Methods and Materials: SV displacement was determined relative to marker registration by using 296 cone beam computed tomography scans of 13 prostate cancer patients with implanted markers. SV were individually registered in the transverse plane, based on gray-value information. The target registration error (TRE) for the SV due tomore » marker registration inaccuracies was estimated. Correlations between prostate gland rotations and SV displacement and between individual SV displacements were determined. Results: The SV registration success rate was 99%. Displacement amounts of both SVs were comparable. Systematic and random residual SV displacements were 1.6 mm and 2.0 mm in the left-right direction, respectively, and 2.8 mm and 3.1 mm in the anteroposterior (AP) direction, respectively. Rotation correction did not reduce residual SV displacement. Prostate gland rotation around the left-right axis correlated with SV AP displacement (R{sup 2} = 42%); a correlation existed between both SVs for AP displacement (R{sup 2} = 62%); considerable correlation existed between random errors of SV displacement and TRE (R{sup 2} = 34%). Conclusions: Considerable residual SV displacement exists in marker-based IGRT. Rotation correction barely reduced SV displacement, rather, a larger SV displacement was shown relative to the prostate gland that was not captured by the marker position. Marker registration error partly explains SV displacement when correcting for rotations. Correcting for rotations, therefore, is not advisable when SV are part of the target volume. Margin design for SVs should take these uncertainties into account.« less
NASA Astrophysics Data System (ADS)
Dembo, N.; Granot, R.; Hamiel, Y.
2017-12-01
The intraplate crustal deformation found in the northern part of the Sinai Microplate, located near the northern Dead Sea Fault plate boundary, is examined. Previous studies have suggested that distributed deformation in Lebanon is accommodated by regional uniform counterclockwise rigid block rotations. However, remanent magnetization directions observed near the Lebanese restraining bend are not entirely homogeneous suggesting that an unexplained and complex internal deformation pattern exists. In order to explain the variations in the amount of vertical-axis rotations we construct a mechanical model of the major active faults in the region that simulates the rotational deformation induced by motion along these faults. The rotational pattern calculated by the mechanical modeling predicts heterogeneous distribution of rotations around the faults. The combined rotation field that considers both the fault induced rotations and the already suggested regional block rotations stands in general agreement with the observed magnetization directions. Overall, the modeling results provide a more detailed and complete picture of the deformation pattern in this region and show that rotations induced by motion along the Dead Sea Fault act in parallel to rigid block rotations. Finally, the new modeling results unravel important insights as to the fashion in which crustal deformation is distributed within the northern part of the Sinai Microplate and propose an improved deformational mechanism that might be appropriate for other plate margins as well.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demissie, Taye B., E-mail: taye.b.demissie@uit.no; Komorovsky, Stanislav; Repisky, Michal
2015-10-28
We present nuclear spin–rotation constants, absolute nuclear magnetic resonance (NMR) shielding constants, and shielding spans of all the nuclei in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br, {sup 127}I), calculated using coupled-cluster singles-and-doubles with a perturbative triples (CCSD(T)) correction theory, four-component relativistic density functional theory (relativistic DFT), and non-relativistic DFT. The total nuclear spin–rotation constants determined by adding the relativistic corrections obtained from DFT calculations to the CCSD(T) values are in general in agreement with available experimental data, indicating that the computational approach followed in this study allows us to predict reliable results formore » the unknown spin–rotation constants in these molecules. The total NMR absolute shielding constants are determined for all the nuclei following the same approach as that applied for the nuclear spin–rotation constants. In most of the molecules, relativistic effects significantly change the computed shielding constants, demonstrating that straightforward application of the non-relativistic formula relating the electronic contribution to the nuclear spin–rotation constants and the paramagnetic contribution to the shielding constants does not yield correct results. We also analyze the origin of the unusually large absolute shielding constant and its relativistic correction of gold in AuF compared to the other gold monohalides.« less
Dynamic deformation measurement and analysis of active stressed lap using optical method
NASA Astrophysics Data System (ADS)
Zhang, Qican; Su, Xianyu; Liu, Yuankun; Xiang, Liqun
2007-12-01
The active stressed lap is the heart of polishing process. A novel non-contact optical method of dynamic deformation measurement and analysis of an active stressed lap is put forward. This method, based on structured illumination, is able to record full-field information of the bending and rotating stressed lap dynamically and continuously, while its profile is changed under computer control, and restore the whole process of lap deformation varied with time at different position and rotating angle. It has been verified by experiments that this proposed method will be helpful to the opticians to ensure the stressed lap as expected.
Moewis, P; Boeth, H; Heller, M O; Yntema, C; Jung, T; Doyscher, R; Ehrig, R M; Zhong, Y; Taylor, W R
2014-07-01
The in vivo quantification of rotational laxity of the knee joint is of importance for monitoring changes in joint stability or the outcome of therapies. While invasive assessments have been used to study rotational laxity, non-invasive methods are attractive particularly for assessing young cohorts. This study aimed to determine the conditions under which tibio-femoral rotational laxity can be assessed reliably and accurately in a non-invasive manner. The reliability and error of non-invasive examinations of rotational joint laxity were determined by comparing the artefact associated with surface mounted markers against simultaneous measurements using fluoroscopy in five knees including healthy and ACL deficient joints. The knees were examined at 0°, 30°, 60° and 90° flexion using a device that allows manual axial rotation of the joint. With a mean RMS error of 9.6°, the largest inaccuracy using non-invasive assessment was present at 0° knee flexion, whereas at 90° knee flexion, a smaller RMS error of 5.7° was found. A Bland and Altman assessment indicated that a proportional bias exists between the non-invasive and fluoroscopic approaches, with limits of agreement that exceeded 20°. Correction using average linear regression functions resulted in a reduction of the RMS error to below 1° and limits of agreement to less than ±1° across all knees and flexion angles. Given the excellent reliability and the fact that a correction of the surface mounted marker based rotation values can be achieved, non-invasive evaluation of tibio-femoral rotation could offer opportunities for simplified devices for use in clinical settings in cases where invasive assessments are not justified. Although surface mounted marker based measurements tend to overestimate joint rotation, and therefore joint laxity, our results indicate that it is possible to correct for this error. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Janis, Jeffrey E; Rohrich, Rod J; Gutowski, Karol A
2005-04-01
Auricular deformities, specifically, prominent ears, are relatively frequent. Although the physiologic consequences are negligible, the aesthetic and psychological effects on the patient can be substantial. Otoplasty techniques are used to correct many auricular deformities, including the prominent ear, the constricted ear, Stahl's deformity, and cryptotia. Various treatments and techniques have been developed for the correction of these deformities, including methods that excise, bend, suture, scratch, or reposition the auricular cartilage. The multitude of different approaches indicates that there is not one clearly definitive technique for correcting these problems. This article reviews the history of otoplasty, its anatomical basis and a method for evaluation, techniques for the correction of the deformity, and potential complications of the procedure.
Millimeter Wave Spectroscopy and Equilibrium Structure Determination of Pyrimidine (m-C_4H_4N_2)
NASA Astrophysics Data System (ADS)
Heim, Zachary N.; Amberger, Brent K.; Esselman, Brian J.; Woods, R. Claude; McMahon, Robert J.
2015-06-01
Pyrimidine, the meta substituted dinitrogen analog of benzene, has been studied in the mm-wave region from 260 - 360 GHz, expanding on previous studies up to 337 GHz. The spectra of all four of the singly-substituted 13C and 15N isotopologues were observed in natural abundance. Samples of deuterium enriched pyrimidine were synthesized, giving access to several deuterium-substituted isotopologues. The experimental rotational constants have been corrected for vibration-rotation coupling and electron mass. The vibration-rotation corrections were calculated with an anharmonic frequency calculation at the CCSD[T]/ANO1 level using CFOUR. An equilibrium structure determination has been performed using the corrected rotational constants with the xrefit module of CFOUR. Several vibrational satellites of pyrimidine have also been studied. Their rotational constants have been compared to those obtained computationally. Z. Kisiel, L. Pszczolkowski, I. R. Medvedev, M. Winnewisser, F. C. De Lucia, E. Herbst, J. Mol. Spectrosc. 233, 231-243 (2005). G. L. Blackman, R. D. Brown, F. R. Burden, J. Mol. Spectrosc. 35, 444-454 (1970). W. Caminati, D. Damiani, Chem. Phys. Lett. 179, 460-462 (1991).
Defensive Abdominal Rotation Patterns of Tenebrionid Beetle, Zophobas atratus, Pupae
Ichikawa, Toshio; Nakamura, Tatsuya; Yamawaki, Yoshifumi
2012-01-01
Exarate pupae of the beetle Zophobas atratus Fab. (Coleoptera: Tenebrionidae) have free appendages (antenna, palp, leg, and elytron) that are highly sensitive to mechanical stimulation. A weak tactile stimulus applied to any appendage initiated a rapid rotation of abdominal segments. High-speed photography revealed that one cycle of defensive abdominal rotation was induced in an all-or-none fashion by bending single or multiple mechanosensory hairs on a leg or prodding the cuticular surface of appendages containing campaniform sensilla. The direction of the abdominal rotation completely depended on the side of stimulation; stimulation of a right appendage induced a right-handed rotation about the anterior-posterior axis of the pupal body and vice versa. The trajectories of the abdominal rotations had an ellipsoidal or pear-shaped pattern. Among the trajectory patterns of the rotations induced by stimulating different appendages, there were occasional significant differences in the horizontal (right-left) component of abdominal rotational movements. Simultaneous stimulation of right and left appendages often induced variable and complex patterns of abdominal movements, suggesting an interaction between sensory signals from different sides. When an abdominal rotation was induced in a freely lying pupa, the rotation usually made the pupa move away from or turn its dorsum toward the source of stimulation with the aid of the caudal processes (urogomphi), which served as a fulcrum for transmitting the power of the abdominal rotation to the movement or turning of the whole body. Pattern generation mechanisms for the abdominal rotation were discussed. PMID:23448289
Defensive abdominal rotation patterns of tenebrionid beetle, Zophobas atratus, pupae.
Ichikawa, Toshio; Nakamura, Tatsuya; Yamawaki, Yoshifumi
2012-01-01
Exarate pupae of the beetle Zophobas atratus Fab. (Coleoptera: Tenebrionidae) have free appendages (antenna, palp, leg, and elytron) that are highly sensitive to mechanical stimulation. A weak tactile stimulus applied to any appendage initiated a rapid rotation of abdominal segments. High-speed photography revealed that one cycle of defensive abdominal rotation was induced in an all-or-none fashion by bending single or multiple mechanosensory hairs on a leg or prodding the cuticular surface of appendages containing campaniform sensilla. The direction of the abdominal rotation completely depended on the side of stimulation; stimulation of a right appendage induced a right-handed rotation about the anterior-posterior axis of the pupal body and vice versa. The trajectories of the abdominal rotations had an ellipsoidal or pear-shaped pattern. Among the trajectory patterns of the rotations induced by stimulating different appendages, there were occasional significant differences in the horizontal (right-left) component of abdominal rotational movements. Simultaneous stimulation of right and left appendages often induced variable and complex patterns of abdominal movements, suggesting an interaction between sensory signals from different sides. When an abdominal rotation was induced in a freely lying pupa, the rotation usually made the pupa move away from or turn its dorsum toward the source of stimulation with the aid of the caudal processes (urogomphi), which served as a fulcrum for transmitting the power of the abdominal rotation to the movement or turning of the whole body. Pattern generation mechanisms for the abdominal rotation were discussed.
The multidirectional bending properties of the human lumbar intervertebral disc.
Spenciner, David; Greene, David; Paiva, James; Palumbo, Mark; Crisco, Joseph
2006-01-01
While the biomechanical properties of the isolated intervertebral disc have been well studied in the three principal anatomic directions of flexion/extension, axial rotation, and lateral bending, there is little data on the properties in the more functional directions that are combinations of these principal anatomic directions. To determine the bending flexibility, range of motion (ROM), and neutral zone (NZ) of the human lumbar disc in multiple directions and to determine if the values about the combined moment axes can be predicted from the values about principal moment axes. Three-dimensional biomechanical analysis of the elastic bending properties of human lumbar discs about principal and combined moment axes. Pure, unconstrained moments were applied about multiple axes. The bending properties (flexibility, ROM, and NZ) of isolated lumbar discs (n=4 for L2/L3 and n=3 for L4/L5) were determined in the six principal directions and in 20 combined directions. The experimental values were compared with those predicted from the linear combination of the six principal moment axes. The maximum and minimum values of the biomechanical properties were found at the principal moment axes. Among combined moment axes, ROM and NZ (but not flexibility) values were predicted from the principal moment axis values. The principal moment axes coincide with the primary mechanical axes of the intervertebral disc and demonstrate significant differences in direction for values of flexibility, ROM, and NZ. Not all combined moment axis values can be predicted from principal moment axis values.
NASA Astrophysics Data System (ADS)
Fukahata, Y.; Matsu'ura, M.
2015-12-01
The most conspicuous cumulative deformation in subduction zones is the formation of island arc-trench system. A pair of anomalies in topography and free-air gravity, high in the arc and low around the trench, is observed without exceptions all over the world. Since the 1960s, elastic dislocation theory has been widely used to interpret coseismic crustal deformation. For the modeling of longer-term crustal deformation, it is necessary to consider viscoelastic properties of the asthenosphere. By simply applying elastic-viscoelastic dislocation theory to plate subduction, Matsu'ura and Sato (1989, GJI) have shown that some crustal deformation remains after the completion of one earthquake cycle, which means that crustal deformation accumulates with time in a long term due to plate subduction. In fact, by constructing a plate interface model in and around Japan, Hashimoto, Fukui and Matsu'ura (2004, PAGEOPH) have demonstrated that the computed vertical displacements due to steady plate subduction well explain the observed free-air gravity anomaly pattern. Recently, we got a lucid explanation of crustal deformation due to plate subduction. In subduction zones, oceanic plates bend and descend into the mantle. Because the bending of oceanic plates is usually not spontaneous, there exists kinematic interaction between the oceanic and overriding plates, which causes cumulative deformation of the overriding plate. This may be understood based on the law of action and reaction: one is bending of an oceanic plate and the other is deformation of the overriding plate. As a special case, it is useful to consider plate subduction along a part of true circle. In this case, crustal deformation due to steady subduction is solely caused by the effect of gravity, because dislocation along a circle does not cause any intrinsic internal deformation. When an oceanic plate is descending along an arcuate plate interface from the right-hand side, according to dislocation theory, the oceanic plate rotates anti-clockwise and the overriding plate rotates clockwise. The gravity, however, requires both plates at a distance from the trench to remain in the original gravitational equilibrium, which results in upward bending of both plates. As subduction proceeds, the deformation of the upward bending accumulates with time.
Effect of rotation on Jeans instability of magnetized radiative quantum plasma
NASA Astrophysics Data System (ADS)
Joshi, H.; Pensia, R. K.
2017-03-01
The influence of rotation on the Jeans instability of homogeneous magnetized radiative quantum plasma is investigated. The basic equations of the problem are constructed and linearized by using the Quantum Magnetohydrodynamics (QMHD) model. The general dispersion relation is obtained by using the normal mode analysis technique, which is reduced for both the transverse and the longitudinal mode of propagations and further it is reduced for the axis of rotation parallel and perpendicular to the magnetic field. We found that the stabilizing effects of rotation are decreases for a strong magnetic field which is shown in the graphical representation. We also found that the quantum correction modified the condition of Jeans instability in both modes of propagation. The stabilizing effect of rotation is more increased in the presence of quantum correction.
Modeling the locomotion of the African trypanosome using multi-particle collision dynamics
NASA Astrophysics Data System (ADS)
Babu, Sujin B.; Stark, Holger
2012-08-01
The African trypanosome is a single flagellated micro-organism that causes the deadly sleeping sickness in humans and animals. We study the locomotion of a model trypanosome by modeling the spindle-shaped cell body using an elastic network of vertices with additional bending rigidity. The flagellum firmly attached to the model cell body is either straight or helical. A bending wave propagates along the flagellum and pushes the trypanosome forward in its viscous environment, which we simulate with the method of multi-particle collision dynamics. The relaxation dynamics of the model cell body due to a static bending wave reveals the sperm number from elastohydrodynamics as the relevant parameter. Characteristic cell body conformations for the helically attached flagellum resemble experimental observations. We show that the swimming velocity scales as the root of the angular frequency of the bending wave reminiscent of predictions for an actuated slender rod attached to a large viscous load. The swimming velocity for one geometry collapses on a single master curve when plotted versus the sperm number. The helically attached flagellum leads to a helical swimming path and a rotation of the model trypanosome about its long axis as observed in experiments. The simulated swimming velocity agrees with the experimental value.
A ring-type multi-DOF ultrasonic motor with four feet driving consistently.
Shi, Shengjun; Xiong, Huaiyin; Liu, Yingxiang; Chen, Weishan; Liu, Junkao
2017-04-01
A new type of multiple-degree-of-freedom (multi-DOF) ultrasonic motor was developed aiming at high output torque and compact structure. To reach this purpose, a ring type composite stator was proposed with four driving feet uniformly arranged in the inner circumference of the ring stator. The stator employs two orthogonal axial bending modes and a radial bending mode, by exciting two of them simultaneously, to generate elliptic trajectories on driving feet tips and to push sphere rotor around x, y and z axis respectively. Based on the deduced criteria, a specific combination of the A(0,5) axial bending modes and R(0,2) radial bending mode were chosen to realize that the rotating directions of the elliptical driving trajectories on four feet tips can push the sphere rotor to spin in the same direction consistently, thus the efficiency and output performance will be improved by decreasing the slip between feet and rotor. FEM was used to design the motor including selecting key parameters to tune the resonant frequencies by sensitivity analysis, and a prototype was fabricated and tested. The experiment results showed that the maximum output torque of the motor is 0.118Nm and the maximum speed is 55r/min. Copyright © 2017 Elsevier B.V. All rights reserved.
DOT National Transportation Integrated Search
1973-07-01
A miniature piezoresistive mouthpiece rotational accelerometer has been developed to measure the angular acceleration of a head during a simulated vehicle crash. Corrections have been electronically applied to the rotational accelerometer to reduce i...
On CD-AFM bias related to probe bending
NASA Astrophysics Data System (ADS)
Ukraintsev, V. A.; Orji, N. G.; Vorburger, T. V.; Dixson, R. G.; Fu, J.; Silver, R. M.
2012-03-01
Critical Dimension AFM (CD-AFM) is a widely used reference metrology. To characterize modern semiconductor devices, very small and flexible probes, often 15 nm to 20 nm in diameter, are now frequently used. Several recent publications have reported on uncontrolled and significant probe-to-probe bias variation during linewidth and sidewall angle measurements [1,2]. Results obtained in this work suggest that probe bending can be on the order of several nanometers and thus potentially can explain much of the observed CD-AFM probe-to-probe bias variation. We have developed and experimentally tested one-dimensional (1D) and two-dimensional (2D) models to describe the bending of cylindrical probes. An earlier 1D bending model reported by Watanabe et al. [3] was refined. Contributions from several new phenomena were considered, including: probe misalignment, diameter variation near the carbon nanotube tip (CNT) apex, probe bending before snapping, distributed van der Waals-London force, etc. The methodology for extraction of the Hamaker probe-surface interaction energy from experimental probe bending data was developed. To overcome limitations of the 1D model, a new 2D distributed force (DF) model was developed. Comparison of the new model with the 1D single point force (SPF) model revealed about 27 % difference in probe bending bias between the two. A simple linear relation between biases predicted by the 1D SPF and 2D DF models was found. This finding simplifies use of the advanced 2D DF model of probe bending in various CD-AFM applications. New 2D and three-dimensional (3D) CDAFM data analysis software is needed to take full advantage of the new bias correction modeling capabilities.
Analyzing refractive index changes and differential bending in microcantilever arrays.
Huber, François; Lang, Hans Peter; Hegner, Martin; Despont, Michel; Drechsler, Ute; Gerber, Christoph
2008-08-01
A new microcantilever array design is investigated comprising eight flexible microcantilevers introducing two solid bars, enabling to subtract contributions from differences in refractive index in an optical laser read out system. Changes in the refractive index do not contribute undesirably to bending signals at picomolar to micromolar DNA or protein concentrations. However, measurements of samples with high salt concentrations or serum are affected, requiring corrections for refractive index artifacts. Moreover, to obtain a deeper understanding of molecular stress formation, the differential curvature of cantilevers is analyzed by positioning the laser spots along the surface of the levers during pH experiments.
NASA Astrophysics Data System (ADS)
Teng, Chuan-xin; Yu, Fang-da; Jing, Ning; Zheng, Jie
2016-09-01
The temperature influence to a refractive index (RI) sensor based on a macro-bending tapered plastic optical fiber (POF) was investigated experimentally. The total temperature dependence loss (TDLtotal) and total temperature dependence RI deviation (TDRtotal) were measured at different temperature (10-60 °C) over an RI range of 1.33-1.41. The temperature dependence RI deviation of the sensor itself was obtained by subtracting the temperature dependence RI of measured liquid from TDRtotal. Therefore, the influence of temperature variation to the sensor was characterized and corrected.
Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.
Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin
2017-09-01
Purpose Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points · Pelvic tilt and rotation influence cup orientation after THA. · Cup anteversion and inclination should be referenced to the pelvis. · Radiological measurement errors of cup position may be reduced by mathematical concepts. Citation Format · Schwarz TJ, Weber M, Dornia C et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Fortschr Röntgenstr 2017; 189: 864 - 873. © Georg Thieme Verlag KG Stuttgart · New York.
Antonov, Ivan O; Barker, Beau J; Heaven, Michael C
2011-01-28
The ground electronic state of BeOBe(+) was probed using the pulsed-field ionization zero electron kinetic energy photoelectron technique. Spectra were rotationally resolved and transitions to the zero-point level, the symmetric stretch fundamental and first two bending vibrational levels were observed. The rotational state symmetry selection rules confirm that the ground electronic state of the cation is (2)Σ(g)(+). Detachment of an electron from the HOMO of neutral BeOBe results in little change in the vibrational or rotational constants, indicating that this orbital is nonbonding in nature. The ionization energy of BeOBe [65480(4) cm(-1)] was refined over previous measurements. Results from recent theoretical calculations for BeOBe(+) (multireference configuration interaction) were found to be in good agreement with the experimental data.
Electron beam machining using rotating and shaped beam power distribution
Elmer, J.W.; O`Brien, D.W.
1996-07-09
An apparatus and method are disclosed for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: (1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and (2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1,000 {micro}m (1 mm or larger), compared to the 250 {micro}m diameter of laser drilling. 5 figs.
Fermions tunnelling from the charged dilatonic black holes
NASA Astrophysics Data System (ADS)
Chen, De-You; Jiang, Qing-Quan; Zu, Xiao-Tao
2008-10-01
Kerner and Mann's recent work shows that for an uncharged and non-rotating black hole its Hawking temperature can be correctly derived by fermions tunnelling from its horizons. In this paper, our main work is to improve the analysis to deal with charged fermion tunnelling from the general dilatonic black holes, specifically including the charged, spherically symmetric dilatonic black hole, the rotating Einstein Maxwell dilaton axion (EMDA) black hole and the rotating Kaluza Klein (KK) black hole. As a result, the correct Hawking temperatures are well recovered by charged fermions tunnelling from these black holes.
SU-E-J-15: A Patient-Centered Scheme to Mitigate Impacts of Treatment Setup Error
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, L; Southern Medical University, Guangzhou; Tian, Z
2014-06-01
Purpose: Current Intensity Modulated Radiation Therapy (IMRT) is plan-centered. At each treatment fraction, we position the patient to match the setup in treatment plan. Inaccurate setup can compromise delivered dose distribution, and hence leading to suboptimal treatments. Moreover, current setup approach via couch shift under image guidance can correct translational errors, while rotational and deformation errors are hard to address. To overcome these problems, we propose in this abstract a patient-centered scheme to mitigate impacts of treatment setup errors. Methods: In the patient-centered scheme, we first position the patient on the couch approximately matching the planned-setup. Our Supercomputing Online Replanningmore » Environment (SCORE) is then employed to design an optimal treatment plan based on the daily patient geometry. It hence mitigates the impacts of treatment setup error and reduces the requirements on setup accuracy. We have conducted simulations studies in 10 head-and-neck (HN) patients to investigate the feasibility of this scheme. Rotational and deformation setup errors were simulated. Specifically, 1, 3, 5, 7 degrees of rotations were put on pitch, roll, and yaw directions; deformation errors were simulated by splitting neck movements into four basic types: rotation, lateral bending, flexion and extension. Setup variation ranges are based on observed numbers in previous studies. Dosimetric impacts of our scheme were evaluated on PTVs and OARs in comparison with original plan dose with original geometry and original plan recalculated dose with new setup geometries. Results: With conventional plan-centered approach, setup error could lead to significant PTV D99 decrease (−0.25∼+32.42%) and contralateral-parotid Dmean increase (−35.09∼+42.90%). The patientcentered approach is effective in mitigating such impacts to 0∼+0.20% and −0.03∼+5.01%, respectively. Computation time is <128 s. Conclusion: Patient-centered scheme is proposed to mitigate setup error impacts using replanning. Its superiority in terms of dosimetric impacts and feasibility has been shown through simulation studies on HN cases.« less
Artificial atlanto-odontoid joint replacement through a transoral approach.
Lu, Bin; He, Xi Jing; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong
2009-01-01
Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P B 0.021) and NZ (P B 0.002) and a significantly increased stiffness (P \\ 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P C 0.719), NZ (P C 0.580), and stiffness (P C 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities.
Artificial atlanto-odontoid joint replacement through a transoral approach
Lu, Bin; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong
2008-01-01
Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1–C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P ≤ 0.021) and NZ (P ≤ 0.002) and a significantly increased stiffness (P < 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P ≥ 0.719), NZ (P ≥ 0.580), and stiffness (P ≥ 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities. PMID:19043745
Lauric, Alexandra; Hippelheuser, James; Safain, Mina G; Malek, Adel M
2014-09-22
Although high-impact hemodynamic forces are thought to lead to cerebral aneurysmal change, little is known about the aneurysm formation on the inner aspect of vascular bends such as the internal carotid artery (ICA) siphon where wall shear stress (WSS) is expected to be low. This study evaluates the effect of vessel curvature and hemodynamics on aneurysm formation along the inner carotid siphon. Catheter 3D-rotational angiographic volumes of 35 ICA (10 aneurysms, 25 controls) were evaluated in 3D for radius of curvature and peak curvature of the siphon bend, followed by univariate statistical analysis. Computational fluid dynamic (CFD) simulations were performed on patient-derived models after aneurysm removal and on synthetic variants of increasing curvature. Peak focal siphon curvature was significantly higher in aneurysm bearing ICAs (0.36 ± 0.045 vs. 0.30 ± 0.048 mm(-1), p=0.003), with no difference in global radius of curvature (p=0.36). In CFD simulations, increasing parametric curvature tightness (from 5 to 3mm radius) resulted in dramatic increase of WSS and WSS gradient magnitude (WSSG) on the inner wall of the bend. In patient-derived data, the location of aneurysms coincided with regions of low WSS (<4 Pa) flanked by high WSS and WSSG peaks. WSS peaks correlated with the aneurysm neck. In contrast, control siphon bends displayed low, almost constant, WSS and WSSG profiles with little spatial variation. High bend curvature induces dynamically fluctuating high proximal WSS and WSSG followed by regions of flow stasis and recirculation, leading to local conditions known to induce destructive vessel wall remodeling and aneurysmal initiation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Isolated penile torsion in newborns.
Eroglu, Egemen; Gundogdu, Gokhan
2015-01-01
We reported on the incidence of isolated penile torsion among our healthy children and our approach to this anomaly. Between 2011 and 2014, newborn babies with penile torsion were classified according to the angle of torsion. Surgical correction (penile degloving and reattachment for moderate cases and dorsal dartos flap technique in case of resistance) after 6 months was advised to the babies with rotations more than 45°. Among 1000 newborn babies, 200 isolated penile torsions were found, and among these, 43 had torsions more than 45°, and 4 of these had angles greater than 90°. The mean angle of the rotations was found 30.45° (median: 20°). In total, 8 children with 60° torsions were previously circumcised. Surgery was performed on 19 patients, with a mean patient age of 12 ± 2 months. Of these 19, 13 babies were corrected with degloving and reattachment. This technique was not enough on the remaining 6 patients; therefore, derotational dorsal dartos flap was added to correct the torsion. After a mean of 15.6 ± 9.8 months, residual penile rotation, less than 15°, was found only in 2 children. The incidence of isolated penile torsion is 20% in newborns. However, rotation more than 45° angles are seen in 4.3% of male babies. Correction is not necessary in mild degrees, and penile degloving with reattachment is enough in most cases. If the initial correction is insufficient, dorsal dartos flap rotation is easy and effective. Prior circumcision neither disturbs the operative procedure nor affects the outcomes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bertholet, Jenny, E-mail: jennbe@rm.dk; Worm, Esben S.; Fledelius, Walther
Purpose: Image guided liver stereotactic body radiation therapy (SBRT) often relies on implanted fiducial markers. The target localization accuracy decreases with increased marker-target distance. This may occur partly because of liver rotations. The aim of this study was to examine time-resolved translations and rotations of liver marker constellations and investigate if time-resolved intrafraction rotational corrections can improve localization accuracy in liver SBRT. Methods and Materials: Twenty-nine patients with 3 implanted markers received SBRT in 3 to 6 fractions. The time-resolved trajectory of each marker was estimated from the projections of 1 to 3 daily cone beam computed tomography scans andmore » used to calculate the translation and rotation of the marker constellation. In all cone beam computed tomography projections, the time-resolved position of each marker was predicted from the position of another surrogate marker by assuming that the marker underwent either (1) the same translation as the surrogate marker; or (2) the same translation as the surrogate marker corrected by the rotation of the marker constellation. The localization accuracy was quantified as the root-mean-square error (RMSE) between the estimated and the actual marker position. For comparison, the RMSE was also calculated when the marker's position was estimated as its mean position for all the projections. Results: The mean translational and rotational range (2nd-98th percentile) was 2.0 mm/3.9° (right-left), 9.2 mm/2.9° (superior-inferior), 4.0 mm/4.0° (anterior-posterior), and 10.5 mm (3-dimensional). Rotational corrections decreased the mean 3-dimensional RMSE from 0.86 mm to 0.54 mm (P<.001) and halved the RMSE increase per millimeter increase in marker distance. Conclusions: Intrafraction rotations during liver SBRT reduce the accuracy of marker-guided target localization. Rotational correction can improve the localization accuracy with a factor of approximately 2 for large marker-target distances.« less
Sul, Onejae; Lee, Seung-Beck
2017-01-01
In this article, we report on a flexible sensor based on a sandpaper molded elastomer that simultaneously detects planar displacement, rotation angle, and vertical contact pressure. When displacement, rotation, and contact pressure are applied, the contact area between the translating top elastomer electrode and the stationary three bottom electrodes change characteristically depending on the movement, making it possible to distinguish between them. The sandpaper molded undulating surface of the elastomer reduces friction at the contact allowing the sensor not to affect the movement during measurement. The sensor showed a 0.25 mm−1 displacement sensitivity with a ±33 μm accuracy, a 0.027 degree−1 of rotation sensitivity with ~0.95 degree accuracy, and a 4.96 kP−1 of pressure sensitivity. For possible application to joint movement detection, we demonstrated that our sensor effectively detected the up-and-down motion of a human forefinger and the bending and straightening motion of a human arm. PMID:28878166
Choi, Eunsuk; Sul, Onejae; Lee, Seung-Beck
2017-09-06
In this article, we report on a flexible sensor based on a sandpaper molded elastomer that simultaneously detects planar displacement, rotation angle, and vertical contact pressure. When displacement, rotation, and contact pressure are applied, the contact area between the translating top elastomer electrode and the stationary three bottom electrodes change characteristically depending on the movement, making it possible to distinguish between them. The sandpaper molded undulating surface of the elastomer reduces friction at the contact allowing the sensor not to affect the movement during measurement. The sensor showed a 0.25 mm −1 displacement sensitivity with a ±33 μm accuracy, a 0.027 degree −1 of rotation sensitivity with ~0.95 degree accuracy, and a 4.96 kP −1 of pressure sensitivity. For possible application to joint movement detection, we demonstrated that our sensor effectively detected the up-and-down motion of a human forefinger and the bending and straightening motion of a human arm.
Localized transversal-rotational modes in linear chains of equal masses.
Pichard, H; Duclos, A; Groby, J-P; Tournat, V; Gusev, V E
2014-01-01
The propagation and localization of transversal-rotational waves in a two-dimensional granular chain of equal masses are analyzed in this study. The masses are infinitely long cylinders possessing one translational and one rotational degree of freedom. Two dispersive propagating modes are predicted in this granular crystal. By considering the semi-infinite chain with a boundary condition applied at its beginning, the analytical study demonstrates the existence of localized modes, each mode composed of two evanescent modes. Their existence, position (either in the gap between the propagating modes or in the gap above the upper propagating mode), and structure of spatial localization are analyzed as a function of the relative strength of the shear and bending interparticle interactions and for different boundary conditions. This demonstrates the existence of a localized mode in a semi-infinite monatomic chain when transversal-rotational waves are considered, while it is well known that these types of modes do not exist when longitudinal waves are considered.
Qiu, Tian-Xia; Teo, Ee-Chon; Lee, Kim-Kheng; Ng, Hong-Wan; Yang, Kai
2004-04-01
The purpose of this study was to determine the locations and loci of instantaneous axes of rotation (IARs) of the T10-T11 motion segment in flexion and extension. An anatomically accurate three-dimensional model of thoracic T10-T11 functional spinal unit (FSU) was developed and validated against published experimental data under flexion, extension, lateral bending, and axial rotation loading configurations. The validated model was exercised under six load configurations that produced motions only in the sagittal plane to characterize the loci of IARs for flexion and extension. The IARs for both flexion and extension under these six load types were directly below the geometric center of the moving vertebra, and all the loci of IARs were tracked superoanteriorly for flexion and inferoposteriorly for extension with rotation. These findings may offer an insight to better understanding of the kinematics of the human thoracic spine and provide clinically relevant information for the evaluation of spinal stability and implant device functionality.
Minimizing Injuries and Enhancing Performance in Golf Through Training Programs
Meira, Erik P.; Brumitt, Jason
2010-01-01
Context: Golf is a popular sport, particularly in older populations. Regardless of age and skill level, golfers risk injury to the back, shoulder, wrist and hand, elbow, and knee. Because of the unique compressive, shear, rotational, and lateral bending forces created in the lumbar region during the golf swing, the primary sport-related malady experienced by amateurs and professionals is low back pain. Extrinsic and intrinsic injury risk factors have been reported in the literature. A growing body of evidence supports the prescription of strength training routines to enhance performance and reduce the risk of injury. Evidence Acquisition: Relevant studies were reviewed on golf injuries, swing mechanics, training routines, and general training program design. The following electronic databases were used to identify research relevant to this report: MEDLINE (from 1950–November 2009), CINAHL (1982–November 2009), and SPORTDiscus (1830–November 2009). Results: Injuries may be associated with lack of warm-up, poor trunk flexibility and strength, faulty swing technique, and overuse. Conclusions: Implementing a training program that includes flexibility, strength, and power training with correction of faulty swing mechanics will help the golfer reduce the likelihood of injury and improve overall performance. PMID:23015957
Dobbe, J G G; du Pré, K J; Blankevoort, L; Streekstra, G J; Kloen, P
2017-08-01
The correction of multiplanar deformity is challenging. We describe preoperative 3-D planning and treatment of a complex tibia malunion using an oblique single-cut rotation osteotomy to correct deformity parameters in the sagittal, coronal and transverse plane. At 5 years postoperatively, the patient ambulates without pain with a well-aligned leg.
Distributed force probe bending model of critical dimension atomic force microscopy bias
NASA Astrophysics Data System (ADS)
Ukraintsev, Vladimir A.; Orji, Ndubuisi G.; Vorburger, Theodore V.; Dixson, Ronald G.; Fu, Joseph; Silver, Rick M.
2013-04-01
Critical dimension atomic force microscopy (CD-AFM) is a widely used reference metrology technique. To characterize modern semiconductor devices, small and flexible probes, often 15 to 20 nm in diameter, are used. Recent studies have reported uncontrolled and significant probe-to-probe bias variation during linewidth and sidewall angle measurements. To understand the source of these variations, tip-sample interactions between high aspect ratio features and small flexible probes, and their influence on measurement bias, should be carefully studied. Using theoretical and experimental procedures, one-dimensional (1-D) and two-dimensional (2-D) models of cylindrical probe bending relevant to carbon nanotube (CNT) AFM probes were developed and tested. An earlier 1-D bending model was refined, and a new 2-D distributed force (DF) model was developed. Contributions from several factors were considered, including: probe misalignment, CNT tip apex diameter variation, probe bending before snapping, and distributed van der Waals-London force. A method for extracting Hamaker probe-surface interaction energy from experimental probe-bending data was developed. Comparison of the new 2-D model with 1-D single point force (SPF) model revealed a difference of about 28% in probe bending. A simple linear relation between biases predicted by the 1-D SPF and 2-D DF models was found. The results suggest that probe bending can be on the order of several nanometers and can partially explain the observed CD-AFM probe-to-probe variation. New 2-D and three-dimensional CD-AFM data analysis software is needed to take full advantage of the new bias correction modeling capabilities.
Koller, Heiko; Schmidt, Rene; Mayer, Michael; Hitzl, Wolfgang; Zenner, Juliane; Midderhoff, Stefan; Middendorf, Stefan; Graf, Nicolaus; Gräf, Nicolaus; Resch, H; Wilke, Hans-Joachim; Willke, Hans-Joachim
2010-12-01
Clinical studies reported frequent failure with anterior instrumented multilevel cervical corpectomies. Hence, posterior augmentation was recommended but necessitates a second approach. Thus, an author group evaluated the feasibility, pull-out characteristics, and accuracy of anterior transpedicular screw (ATPS) fixation. Although first success with clinical application of ATPS has already been reported, no data exist on biomechanical characteristics of an ATPS-plate system enabling transpedicular end-level fixation in advanced instabilities. Therefore, we evaluated biomechanical qualities of an ATPS prototype C4-C7 for reduction of range of motion (ROM) and primary stability in a non-destructive setup among five constructs: anterior plate, posterior all-lateral mass screw construct, posterior construct with lateral mass screws C5 + C6 and end-level fixation using pedicle screws unilaterally or bilaterally, and a 360° construct. 12 human spines C3-T1 were divided into two groups. Four constructs were tested in group 1 and three in group 2; the ATPS prototypes were tested in both groups. Specimens were subjected to flexibility test in a spine motion tester at intact state and after 2-level corpectomy C5-C6 with subsequent reconstruction using a distractable cage and one of the osteosynthesis mentioned above. ROM in flexion-extension, axial rotation, and lateral bending was reported as normalized values. All instrumentations but the anterior plate showed significant reduction of ROM for all directions compared to the intact state. The 360° construct outperformed all others in terms of reducing ROM. While there were no significant differences between the 360° and posterior constructs in flexion-extension and lateral bending, the 360° constructs were significantly more stable in axial rotation. Concerning primary stability of ATPS prototypes, there were no significant differences compared to posterior-only constructs in flexion-extension and axial rotation. The 360° construct showed significant differences to the ATPS prototypes in flexion-extension, while no significant differences existed in axial rotation. But in lateral bending, the ATPS prototype and the anterior plate performed significantly worse than the posterior constructs. ATPS was shown to confer increased primary stability compared to the anterior plate in flexion-extension and axial rotation with the latter yielding significance. We showed that primary stability after 2-level corpectomy reconstruction using ATPS prototypes compared favorably to posterior systems and superior to anterior plates. From the biomechanical point, the 360° instrumentation was shown the most efficient for reconstruction of 2-level corpectomies. Further studies will elucidate whether fatigue testing will enhance the benefit of transpedicular anchorage with posterior constructs and ATPS.
Developments in blade shape design for a Darrieus vertical axis wind turbine
NASA Astrophysics Data System (ADS)
Ashwill, T. D.; Leonard, T. M.
1986-09-01
A new computer program package has been developed that determines the troposkein shape for a Darrieus Vertical Axis Wind Turbine Blade with any geometrical configuration or rotation rate. This package allows users to interact and develop a buildable blade whose shape closely approximates the troposkein. Use of this package can significantly reduce flatwise mean bending stresses in the blade and increase fatigue life.
Bent Bragg–Laue monochromator for high-energy X-rays
Shi, Xianbo; Xu, Wenqian; Yakovenko, Andrey; ...
2017-07-26
A bent Bragg–Laue monochromator (BLM) is proposed for high-energy X-ray (~25–60 keV) beamlines. The BLM has the unique feature of bi-directional focusing. A sagittally bent Laue crystal can focus the large horizontal fan of a bending magnet or wiggler source. A meridionally bent Bragg crystal focuses the beam vertically and corrects for the anticlastic bending effects of the Laue crystal. This monochromator geometry relies on the crystal orientations being optimized. We show that the focusing condition and Rowland condition can be simultaneously satisfied at a given energy. A detailed ray tracings indicate that a BLM can provide similar energy resolutionmore » and higher flux density compared to a sagittally bent double-Laue monochromator configuration. A prototype BLM with a symmetric Bragg crystal and an asymmetric Laue crystal was tested. Matching of the bend radii of the two crystals in the meridional direction was demonstrated. Generally, the horizontal acceptance of the sagittally bent Laue crystal is limited by the large curvature. This horizontal BLM acceptance could be increased by translating the Laue crystal along its sagittal bending axis.« less
Bent Bragg–Laue monochromator for high-energy X-rays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Xianbo; Xu, Wenqian; Yakovenko, Andrey
A bent Bragg–Laue monochromator (BLM) is proposed for high-energy X-ray (~25–60 keV) beamlines. The BLM has the unique feature of bi-directional focusing. A sagittally bent Laue crystal can focus the large horizontal fan of a bending magnet or wiggler source. A meridionally bent Bragg crystal focuses the beam vertically and corrects for the anticlastic bending effects of the Laue crystal. This monochromator geometry relies on the crystal orientations being optimized. We show that the focusing condition and Rowland condition can be simultaneously satisfied at a given energy. A detailed ray tracings indicate that a BLM can provide similar energy resolutionmore » and higher flux density compared to a sagittally bent double-Laue monochromator configuration. A prototype BLM with a symmetric Bragg crystal and an asymmetric Laue crystal was tested. Matching of the bend radii of the two crystals in the meridional direction was demonstrated. Generally, the horizontal acceptance of the sagittally bent Laue crystal is limited by the large curvature. This horizontal BLM acceptance could be increased by translating the Laue crystal along its sagittal bending axis.« less
Dmitriev, Anton E; Kuklo, Timothy R; Lehman, Ronald A; Rosner, Michael K
2007-03-15
This is an in vitro biomechanical study. The current investigation was performed to evaluate the stabilizing potential of anterior, posterior, and circumferential cervical fixation on operative and adjacent segment motion following 2 and 3-level reconstructions. Previous studies reported increases in adjacent level range of motion (ROM) and intradiscal pressure following single-level cervical arthrodesis; however, no studies have compared adjacent level effects following multilevel anterior versus posterior reconstructions. Ten human cadaveric cervical spines were biomechanically tested using an unconstrained spine simulator under axial rotation, flexion-extension, and lateral bending loading. After intact analysis, all specimens were sequentially instrumented from C3 to C5 with: (1) lateral mass fixation, (2) anterior cervical plate with interbody cages, and (3) combined anterior and posterior fixation. Following biomechanical analysis of 2-level constructs, fixation was extended to C6 and testing repeated. Full ROM was monitored at the operative and adjacent levels, and data normalized to the intact (100%). All reconstructive methods reduced operative level ROM relative to intact specimens under all loading methods (P < 0.05). However, circumferential fixation provided the greatest segmental stability among 2 and 3-level constructs (P < 0.05). Moreover, anterior cervical plate fixation was least efficient at stabilizing operative segments following C3-C6 arthrodesis (P < 0.05). Supradjacent ROM was increased for all treatment groups compared to normal data during flexion-extension testing (P < 0.05). Similar trends were observed under axial rotation and lateral bending loading. At the distal level, flexion-extension and axial rotation testing revealed comparable intergroup differences (P < 0.05), while lateral bending loading indicated greater ROM following 2-level circumferential fixation (P < 0.05). Results from our study revealed greater adjacent level motion following all 3 fixation types. No consistent significant intergroup differences in neighboring segment kinematics were detected among reconstructions. Circumferential fixation provided the greatest level of segmental stability without additional significant increase in adjacent level ROM.
Biomechanical Evaluation of the CD HORIZON Spire Z Spinal System With Pedicle and Facet Fixation.
Godzik, Jakub; Kalb, Samuel; Martinez-Del-Campo, Eduardo; Newcomb, Anna G U S; Singh, Vaneet; Walker, Corey T; Chang, Steve W; Kelly, Brian P; Crawford, Neil R
2016-08-01
Human cadaveric biomechanical study. The aim of this study was to evaluate the biomechanics of lumbar motion segments instrumented with the CD HORIZON Spire Z plate system (Spire Z), a posterior supplemental fixation spinous process plate, alone and with additional fixation systems. Plates and pedicle screw/rod and facet screw implants are adjuncts to fusion. The plate limits motion, improving segmental stability and the fusion microenvironment. However, the degree to which the plate contributes to overall stability when used alone or in conjunction with additional instrumentation has not been described. Standard nondestructive flexibility tests were performed in 7 L2-L5 human cadaveric spines. Spinal stability was determined as mean range of motion (ROM) in flexion/extension, lateral bending, and axial rotation. Paired comparisons were made between five conditions: (1) intact/control; (2) Spire Z; (3) Spire Z with unilateral pedicle screw/rod system (Spire Z+UPS); (4) Spire Z with unilateral facet screw system (Spire Z+UFS); and (5) Spire Z with bilateral facet screw system (Spire Z+BFS). Stiffness and ROM data were compared using one-way analysis of variance, followed by repeated-measures Holm-Šidák tests. Spire Z was most effective in limiting flexion (20% of normal) and extension (24% of normal), but less effective in reducing lateral bending and axial rotation. In lateral bending, Spire Z+BFS and Spire Z+UPS constructs were not significantly different and demonstrated greater ROM reduction compared with Spire Z+UFS and Spire Z (P < 0.001). Spire Z+BFS demonstrated greatest stiffness in axial rotation compared with Spire Z+UPS (P = 0.025), Spire Z+UFS (P = 0.001), and Spire Z (P < 0.001). Spire Z+UPS was not significantly different from Spire Z+UFS (P = 0.21), and superior to Spire Z (P = 0.013). The Spire Z spinous process plate provides excellent immediate fixation, particularly for flexion and extension. While the hybrid Spire Z+BFS screw construct afforded the greatest stability, Spire Z+UPS demonstrated considerable promise. N/A.
Renner-Teller effects in the photoelectron spectra of CNC, CCN, and HCCN.
Coudert, Laurent H; Gans, Bérenger; Garcia, Gustavo A; Loison, Jean-Christophe
2018-02-07
The line intensity of photoelectron spectra when either the neutral or cationic species display a Renner-Teller coupling is derived and applied to the modeling of the photoelectron spectra of CNC, CCN, and HCCN. The rovibronic energy levels of these three radicals and of their cations are investigated starting from ab initio results. A model treating simultaneously the bending mode and the overall rotation is developed to deal with the quasilinearity problem in CNC + , CCN + , and HCCN and accounts for the large amplitude nature of their bending mode. This model is extended to treat the Renner-Teller coupling in CNC, CCN, and HCCN + . Based on the derived photoelectron line intensity, the photoelectron spectra of all three molecules are calculated and compared to the experimental ones.
Estimation of blade airloads from rotor blade bending moments
NASA Technical Reports Server (NTRS)
Bousman, William G.
1987-01-01
This paper presents a method for the estimation of blade airloads, based on the measurements of flap bending moments. In this procedure, the blade rotation in vacuum modes is calculated, and the airloads are expressed as an algebraic sum of the mode shapes, modal amplitudes, mass distribution, and frequency properties. The method was validated by comparing the calculated airload distribution with the original wind tunnel measurements which were made using ten modes and twenty measurement stations. Good agreement between the predicted and the measured airloads was found up to 0.90 R, but the agreement degraded towards the blade tip. The method is shown to be quite robust to the type of experimental problems that could be expected to occur in the testing of full-scale and model-scale rotors.
Impact of centrifugal drifts on ion turbulent transport
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belli, Emily A.; Candy, J.
Here, the influence of sonic toroidal rotation on gyrokinetic stability and transport is studied, with important implications for heavy impurity dynamics. When centrifugal drifts and electrostatic trapping corrections are included, significant modifications to the calculated transport of heavy impurities are observed. These high-rotation corrections add to the standard Coriolis drift and toroidal rotation shear drive which are normally included in gyrokinetics. Yet, because of their complexity, centrifugal and electrostatic trapping terms (quadratic in the main ion Mach number) are not generally included in gyrokinetic codes. In this work, we explore the implications of using reduced descriptions of the rotational physics.more » For heavy impurities such as tungsten, cross terms due to the centrifugal force can dominate the rotation dynamics, and neglecting them is shown to lead to large errors in the impurity particle flux.« less
Impact of centrifugal drifts on ion turbulent transport
Belli, Emily A.; Candy, J.
2018-03-01
Here, the influence of sonic toroidal rotation on gyrokinetic stability and transport is studied, with important implications for heavy impurity dynamics. When centrifugal drifts and electrostatic trapping corrections are included, significant modifications to the calculated transport of heavy impurities are observed. These high-rotation corrections add to the standard Coriolis drift and toroidal rotation shear drive which are normally included in gyrokinetics. Yet, because of their complexity, centrifugal and electrostatic trapping terms (quadratic in the main ion Mach number) are not generally included in gyrokinetic codes. In this work, we explore the implications of using reduced descriptions of the rotational physics.more » For heavy impurities such as tungsten, cross terms due to the centrifugal force can dominate the rotation dynamics, and neglecting them is shown to lead to large errors in the impurity particle flux.« less
The nonlinear bending response of thin-walled laminated composite cylinders
NASA Technical Reports Server (NTRS)
Fuchs, Hannes P.; Hyer, Michael W.
1992-01-01
The geometrically nonlinear Donnell shell theory is applied to the problem of stable bending of thin-walled circular cylinders. Responses are computed for cylinders with a radius-to-thickness ratio of 50 and length-to-radius ratios of 1 and 5. Four laminated composite cylinders and an aluminum cylinder are considered. Critical moment estimates are presented for short cylinders for which compression-type buckling behavior is important, and for very long cylinders for which the cross-section flattening, i.e., Brazier effect, is important. A finite element analysis is used to estimate the critical end rotation in addition to establishing the range of validity of the prebuckling analysis. The radial displacement response shows that the character of the boundary layer is significantly influenced by the geometric nonlinearities. Application of a first ply failure analysis using the maximum stress criterion suggests that in nearly all instances material failure occurs before buckling. Failure of the composite cylinders can be attributed to fiber breakage. Striking similarities are seen between the prebuckling displacements of the bending problem and axial compression problem for short cylinders.
Agarwal, A.; Lasenby, J.
2017-01-01
We present a novel application of rotors in geometric algebra to represent the change of curvature tensor that is used in shell theory as part of the constitutive law. We introduce a new decomposition of the change of curvature tensor, which has explicit terms for changes of curvature due to initial curvature combined with strain, and changes in rotation over the surface. We use this decomposition to perform a scaling analysis of the relative importance of bending and stretching in flexible tubes undergoing self-excited oscillations. These oscillations have relevance to the lung, in which it is believed that they are responsible for wheezing. The new analysis is necessitated by the fact that the working fluid is air, compared to water in most previous work. We use stereographic imaging to empirically measure the relative importance of bending and stretching energy in observed self-excited oscillations. This enables us to validate our scaling analysis. We show that bending energy is dominated by stretching energy, and the scaling analysis makes clear that this will remain true for tubes in the airways of the lung. PMID:29291106
Pereira, Erika S J; Gomes, Renata O; Leroy, Agnès M F; Singh, Rupinderpal; Peters, Ove A; Bahia, Maria G A; Buono, Vicente T L
2013-12-01
Comparison of physical and mechanical properties of one conventional and a new NiTi wire, which had received an additional thermomechanical treatment. Specimens of both conventional (NiTi) and the new type of wire, called M-Wire (MW), were subjected to tensile and three-point bending tests, Vickers microhardness measurements, and to rotating-bending fatigue tests at a strain-controlled level of 6%. Fracture surfaces were observed by scanning electron microscopy and the non-deformed microstructures by transmission electron microscopy. The thermomechanical treatment applied to produce the M-Wire apparently increased the tensile strength and Vickers microhardness of the material, but its apparent Young modulus was smaller than that of conventionally treated NiTi. The three-point bending tests showed a higher flexibility for MW which also exhibited a significantly higher number of cycles to failure. M-Wire presented mechanical properties that can render endodontic instruments more flexible and fatigue resistant than those made with conventionally processed NiTi wires. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Gregory, A L; Agarwal, A; Lasenby, J
2017-11-01
We present a novel application of rotors in geometric algebra to represent the change of curvature tensor that is used in shell theory as part of the constitutive law. We introduce a new decomposition of the change of curvature tensor, which has explicit terms for changes of curvature due to initial curvature combined with strain, and changes in rotation over the surface. We use this decomposition to perform a scaling analysis of the relative importance of bending and stretching in flexible tubes undergoing self-excited oscillations. These oscillations have relevance to the lung, in which it is believed that they are responsible for wheezing. The new analysis is necessitated by the fact that the working fluid is air, compared to water in most previous work. We use stereographic imaging to empirically measure the relative importance of bending and stretching energy in observed self-excited oscillations. This enables us to validate our scaling analysis. We show that bending energy is dominated by stretching energy, and the scaling analysis makes clear that this will remain true for tubes in the airways of the lung.
Pedrocchi, Alessandra; Baroni, Guido; Pedotti, Antonio; Massion, Jean; Ferrigno, Giancarlo
2005-04-01
This study deals with the quantitative assessment of exchanged forces and torques at the restraint point during whole body posture perturbation movements in long-term microgravity. The work was based on the results of a previous study focused on trunk bending protocol, which suggested that the minimization of the torques exchanged at the restraint point could be a strategy for movement planning in microgravity (J. Biomech. 36(11) (2003) 1691). Torques minimization would lead to the optimization of muscles activity, to the minimization of energy expenditure and, ultimately, to higher movement control capabilities. Here, we focus on leg lateral abduction from anchored stance. The analysis was based on inverse dynamic modelling, leading to the estimation of the total angular momentum at the supporting ankle joint. Results agree with those obtained for trunk bending movements and point out a consistent minimization of the torques exchanged at the restraint point in weightlessness. Given the kinematic features of the examined motor task, this strategy was interpreted as a way to master the rotational dynamic effects on the frontal plane produced by leg lateral abduction. This postural stabilizing effects was the result of a multi-segmental compensation strategy, consisting of the counter rotation of the supporting limb and trunk accompanying the leg raising. The observed consistency of movement-posture co-ordination patterns among lateral leg raising and trunk bending is put forward as a novel interpretative issue of the adaptation mechanisms of the motor system to sustained microgravity, especially if one considers the completely different kinematics of the centre of mass, which was observed in weightlessness for these two motor tasks.
Song, Young Seop; Yang, Kyung Yong; Youn, Kibum; Yoon, Chiyul; Yeom, Jiwoon; Hwang, Hyeoncheol; Lee, Jehee; Kim, Keewon
2016-08-01
To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland-Altman plot with 95% limits of agreement (LoA). MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in -40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in -40° to 40° range were fair for all motions. Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.
NASA Astrophysics Data System (ADS)
Zhang, Yuluan; Li, Wenguang; Luo, Wei; Zhu, Yu; Duan, Chuanxi
2017-06-01
The rotationally resolved infrared spectra of (HCOOH)2, (HCOOD)2, and HCOOH—HCOOD complexes have been measured in 7.2 μm region by using a segmented rapid-scan distributed-feedback quantum cascade laser absorption spectrometer to probe a slit supersonic jet expansion. The observed spectra are assigned to the v21 (H—C/O—H in-plane bending) fundamental band of (HCOOH)2, the v15 (H—C/O—D in-plane bending) fundamental band of HCOOH—HCOOD, and the v20 (H—C—O in-plane bending) fundamental band of (HCOOD)2. Strong local perturbations caused by the rotation-tunneling coupling between two tunneling components are observed in (HCOOH)2. The v21 fundamental band of (HCOOH)2 and the previously measured v22 fundamental and v12 + v14 combination bands [K. G. Goroya et al., J. Chem. Phys. 140, 164311 (2014)] are analyzed together, yielding a more precise tunneling splitting in the ground state, 0.011 367(92) cm-1. The band-origin of the v21 band of (HCOOH)2 is 1371.776 74(8) cm-1, and the tunneling splitting decreases to 0.000 38(18) cm-1 upon the vibrational excitation. The vibrational energy is 1386.755 49(16) cm-1 for the v15 vibrational mode of HCOOH—HCOOD and 1391.084 39(17) cm-1 for the v20 vibrational mode of (HCOOD)2. No apparent spectral splittings are resolved for HCOOH—HCOOD and (HCOOD)2 under our experimental conditions. The tunneling splitting in the ground state of HCOOH—HCOOD is estimated to be 0.001 13 cm-1 from its average linewidth.
Kingma, Idsart; Bosch, Tim; Bruins, Louis; van Dieën, Jaap H
2004-10-22
This study investigated the effects of initial load height and foot placement instruction in four lifting techniques: free, stoop (bending the back), squat (bending the knees) and a modified squat technique (bending the knees and rotating them outward). A 2D dynamic linked segment model was combined with an EMG assisted trunk muscle model to quantify kinematics and low back loading in 10 subjects performing 19 different lifting movements, using 10.5 kg boxes without handles. When lifting from a 0.05 m height with the feet behind the box, squat lifting resulted in 19.9% (SD 8.7%) higher net moments (p < 0.001) and 17.0% (SD 13.2%) higher compression forces (p < 0.01) than stoop lifting. This effect was reduced to 12.8% (SD 10.7%) for moments and a non-significant 7.4% (SD 16.0%) for compression forces when lifting with the feet beside the box and it disappeared when lifting from 0.5 m height. Differences between squat and stoop lifts, as well as the interaction with lifting height, could to a large extent be explained by changes in the horizontal L5/S1 intervertebral joint position relative to the load, the upper body acceleration, and lumbar flexion. Rotating the knees outward during squat lifts resulted in moments and compression forces that were smaller than in squat lifting but larger than in stoop lifting. Shear forces were small ( < 300 N) at the L4/L5 joint and substantial (1100 - 1400 N) but unaffected by lifting technique at the L5/S1 joint. The present results show that the effects of lifting technique on low back loading depend on the task context.
NASA Astrophysics Data System (ADS)
Gans, B.; Falvo, Cyril; Coudert, L. H.; Garcia, Gustavo A.; Küger, J.; Loison, J.-C.
2017-06-01
The HCCN radical, already detected in the interstellar medium, is also important for nitrile chemistry in Titan's atmosphere. Quite recently the photoionization spectrum of the radical has been recorded using mass selected threshold photoelectron (TPE) spectroscopy and this provided us with the first spectroscopic information about the HCCN} cation. Modeling such a spectrum requires accounting for the non-rigidity of HCCN and for the Renner-Teller effect in HCCN+. In its ^3A'' electronic ground state, HCCN is a non-rigid molecule as the potential for the \\angle{HCC} bending angle is very shallow. Vibronic couplings with the same bending angle leads, in the ^2Π electronic ground state of HCCN+, to a strong Renner-Teller effect giving rise to a bent ^2A' and a quasi-linear ^2A'' state. In this paper the photoionization spectrum of the HCCN radical is simulated. The model developped treats the \\angle{HCC} bending angle as a large amplitude coordinate in both the radical and the cation and accounts for the overall rotation and the Renner-Teller couplings. Gaussian quadrature are used to calculate matrix elements of the three potential energy functions retrieved through ab initio calculations and rovibrational operators going to infinity for the linear configuration are treated rigorously. The HCCN TPE spectrum is computed with the above model calculating all rotational components and choosing the appropriate lineshape. This synthetic spectrum will be shown in the paper and compared with the experimental one.^b Guélin and Cernicharo, A&A 244 (1991) L21 Loison et al., Icarus 247 (2015) 218 Garcia, Krüger, Gans, Falvo, Coudert, and Loison, J. Chem. Phys. (2017) submitted Koput, J. Phys. Chem. A 106 (2002) 6183 Zhao, Zhang, and Sun, J. Phys. Chem. A 112 (2008) 12125
Lumbar Facet Joint Motion in Patients with Degenerative Disc Disease at Affected and Adjacent Levels
Li, Weishi; Wang, Shaobai; Xia, Qun; Passias, Peter; Kozanek, Michal; Wood, Kirkham; Li, Guoan
2013-01-01
Study Design Controlled laboratory study. Objective To evaluate the effect of lumbar degenerative disc diseases (DDDs) on motion of the facet joints during functional weight-bearing activities. Summary of Background Data It has been suggested that DDD adversely affects the biomechanical behavior of the facet joints. Altered facet joint motion, in turn, has been thought to associate with various types of lumbar spine pathology including facet degeneration, neural impingement, and DDD progression. However, to date, no data have been reported on the motion patterns of the lumbar facet joint in DDD patients. Methods Ten symptomatic patients of DDD at L4–S1 were studied. Each participant underwent magnetic resonance images to obtain three-dimensional models of the lumbar vertebrae (L2–S1) and dual fluoroscopic imaging during three characteristic trunk motions: left-right torsion, left-right bending, and flexion-extension. In vivo positions of the vertebrae were reproduced by matching the three-dimensional models of the vertebrae to their outlines on the fluoroscopic images. The kinematics of the facet joints and the ranges of motion (ROMs) were compared with a group of healthy participants reported in a previous study. Results In facet joints of the DDD patients, there was no predominant axis of rotation and no difference in ROMs was found between the different levels. During left-right torsion, the ROMs were similar between the DDD patients and the healthy participants. During left-right bending, the rotation around mediolateral axis at L4–L5, in the DDD patients, was significantly larger than that of the healthy participants. During flexion-extension, the rotations around anterioposterior axis at L4–L5 and around craniocaudal axis at the adjacent level (L3–L4), in the DDD patients, were also significantly larger, whereas the rotation around mediolateral axis at both L2–L3 and L3–L4 levels in the DDD patients were significantly smaller than those of the healthy participants. Conclusion DDD alters the ROMs of the facet joints. The rotations can increase significantly not only at the DDD levels but also at their adjacent levels when compared to those of the healthy participants. The increase in rotations did not occur around the primary rotation axis of the torso motion but around the coupled axes. This hypermobility in coupled rotations might imply a biomechanical mechanism related to DDD. PMID:21270686
Super-global distortion correction for a rotational C-arm x-ray image intensifier.
Liu, R R; Rudin, S; Bednarek, D R
1999-09-01
Image intensifier (II) distortion changes as a function of C-arm rotation angle because of changes in the orientation of the II with the earth's or other stray magnetic fields. For cone-beam computed tomography (CT), distortion correction for all angles is essential. The new super-global distortion correction consists of a model to continuously correct II distortion not only at each location in the image but for every rotational angle of the C arm. Calibration bead images were acquired with a standard C arm in 9 in. II mode. The super-global (SG) model is obtained from the single-plane global correction of the selected calibration images with given sampling angle interval. The fifth-order single-plane global corrections yielded a residual rms error of 0.20 pixels, while the SG model yielded a rms error of 0.21 pixels, a negligibly small difference. We evaluated the accuracy dependence of the SG model on various factors, such as the single-plane global fitting order, SG order, and angular sampling interval. We found that a good SG model can be obtained using a sixth-order SG polynomial fit based on the fifth-order single-plane global correction, and that a 10 degrees sampling interval was sufficient. Thus, the SG model saves processing resources and storage space. The residual errors from the mechanical errors of the x-ray system were also investigated, and found comparable with the SG residual error. Additionally, a single-plane global correction was done in the cylindrical coordinate system, and physical information about pincushion distortion and S distortion were observed and analyzed; however, this method is not recommended due to a lack of calculational efficiency. In conclusion, the SG model provides an accurate, fast, and simple correction for rotational C-arm images, which may be used for cone-beam CT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Guowei; Sun, Qingping; Zeng, Danielle
In current work, unidirectional (UD) carbon fiber composite hatsection component with two different layups are studied under dynamic 3 point bending loading. The experiments are performed at various impact velocities, and the effects of impactor velocity and layup on acceleration histories are compared. A macro model is established with LS-Dyna for more detailed study. The simulation results show that the delamination plays an important role during dynamic 3 point bending test. Based on the analysis with high speed camera, the sidewall of hatsection shows significant buckling rather than failure. Without considering the delamination, current material model cannot capture the postmore » failure phenomenon correctly. The sidewall delamination is modeled by assumption of larger failure strain together with slim parameters, and the simulation results of different impact velocities and layups match the experimental results reasonable well.« less
Neurula rotation determines left-right asymmetry in ascidian tadpole larvae.
Nishide, Kazuhiko; Mugitani, Michio; Kumano, Gaku; Nishida, Hiroki
2012-04-01
Tadpole larvae of the ascidian Halocynthia roretzi show morphological left-right asymmetry. The tail invariably bends towards the left side within the vitelline membrane. The structure of the larval brain is remarkably asymmetric. nodal, a conserved gene that shows left-sided expression, is also expressed on the left side in H. roretzi but in the epidermis unlike in vertebrates. We show that nodal signaling at the late neurula stage is required for stereotypic morphological left-right asymmetry at later stages. We uncover a novel mechanism to break embryonic symmetry, in which rotation of whole embryos provides the initial cue for left-sided expression of nodal. Two hours prior to the onset of nodal expression, the neurula embryo rotates along the anterior-posterior axis in a counterclockwise direction when seen in posterior view, and then this rotation stops when the left side of the embryo is oriented downwards. It is likely that epidermis monocilia, which appear at the neurula rotation stage, generate the driving force for the rotation. When the embryo lies on the left side, protrusion of the neural fold physically prevents it from rotating further. Experiments in which neurula rotation is perturbed by various means, including centrifugation and sandwiching between glass, indicate that contact of the left epidermis with the vitelline membrane as a consequence of neurula rotation promotes nodal expression in the left epidermis. We suggest that chemical, and not mechanical, signals from the vitelline membrane promote nodal expression. Neurula rotation is also conserved in other ascidian species.
Krings, Markus; Nyakatura, John A; Boumans, Mark L L M; Fischer, Martin S; Wagner, Hermann
2017-07-01
Owls are known for their outstanding neck mobility: these birds can rotate their heads more than 270°. The anatomical basis of this extraordinary neck rotation ability is not well understood. We used X-ray fluoroscopy of living owls as well as forced neck rotations in dead specimens and computer tomographic (CT) reconstructions to study how the individual cervical joints contribute to head rotation in barn owls (Tyto furcata pratincola). The X-ray data showed the natural posture of the neck, and the reconstructions of the CT-scans provided the shapes of the individual vertebrae. Joint mobility was analyzed in a spherical coordinate system. The rotational capability was described as rotation about the yaw and roll axes. The analyses suggest a functional division of the cervical spine into several regions. Most importantly, an upper region shows high rolling and yawing capabilities. The mobility of the lower, more horizontally oriented joints of the cervical spine is restricted mainly to the roll axis. These rolling movements lead to lateral bending, effectively resulting in a side shift of the head compared with the trunk during large rotations. The joints in the middle of the cervical spine proved to contribute less to head rotation. The analysis of joint mobility demonstrated how owls might maximize horizontal head rotation by a specific and variable combination of yawing and rolling in functionally diverse regions of the neck. © 2017 Anatomical Society.
Huang, Zifang; Wang, Qifei; Yang, Junlin; Yang, Jingfan; Li, Fobao
2016-04-01
This was a retrospective study. The aim of this study was to compare radiographic outcomes of Lenke 5C adolescent idiopathic scoliosis (AIS) patients treated by vertebral column manipulator (VCM) or simple rod derotation (SRD) maneuver. The direct vertebral rotation (DVR) technique has demonstrated better rotational and coronal correction than SRD, but clinical radiographic outcomes for Lenke 5C AIS following DVR using a VCM derotational device have not been described. A retrospective study was carried out in 39 Lenke 5C AIS patients treated by VCM (n=20) or SRD (n=19) techniques between April 2008 and June 2011. All patients had complete clinical record and radiographic data. Nine radiographic variables were collected and compared at 3 time points (preoperative, immediate postoperative, and minimum 2-year follow-up) between both groups. Scoliosis was successfully corrected in both groups. All patients obtained good coronal and sagittal balance, and no severe complications occurred. The postoperative apical rotation corrective rate of the VCM and SRD groups were 55.1% and 25.5%, respectively (P < 0.05). Lowest instrumented vertebra and stable vertebra (LIV-SV) was statistically significant between the VCM and SRD groups, the mean values were 1.2 ± 0.4 level and 0.7 ± 0.5 level (P < 0.05). The main curve corrective rates and LIV-tilt angle correction rates were not significantly different between groups, but it showed a spontaneous correction for the coronal LIV-tilt angle for both groups at the last follow-up. VCM improved postoperative apical axial rotational correction and lessened the lumbar fusion segment compared with the SRD technique, which might have a potential trend to reserve lumbar mobility.
NASA Technical Reports Server (NTRS)
Royden, H. N.; Green, D. W.; Walson, G. R.
1981-01-01
Faraday-rotation data from the linearly polarized 137-MHz beacons of the ATS-1, SIRIO, and Kiku-2 geosynchronous satellites are used to determine the ionospheric corrections to the range and Doppler data for interplanetary spacecraft navigation. The JPL operates the Deep Space Network of tracking stations for NASA; these stations monitor Faraday rotation with dual orthogonal, linearly polarized antennas, Teledyne polarization tracking receivers, analog-to-digital converter/scanners, and other support equipment. Computer software examines the Faraday data, resolves the pi ambiguities, constructs a continuous Faraday-rotation profile and converts the profile to columnar zenith total electron content at the ionospheric reference point; a second program computes the line-of-sight ionospheric correction for each pass of the spacecraft over each tracking complex. Line-of-sight ionospheric electron content using mapped Faraday-rotation data is compared with that using dispersive Doppler data from the Voyager spacecraft; a difference of about 0.4 meters, or 5 x 10 to the 16th electrons/sq m is obtained. The technique of determining the electron content of interplanetary plasma by subtraction of the ionospheric contribution is demonstrated on the plasma torus surrounding the orbit of Io.
The mechanics of fault-bend folding and tear-fault systems in the Niger Delta
NASA Astrophysics Data System (ADS)
Benesh, Nathan Philip
This dissertation investigates the mechanics of fault-bend folding using the discrete element method (DEM) and explores the nature of tear-fault systems in the deep-water Niger Delta fold-and-thrust belt. In Chapter 1, we employ the DEM to investigate the development of growth structures in anticlinal fault-bend folds. This work was inspired by observations that growth strata in active folds show a pronounced upward decrease in bed dip, in contrast to traditional kinematic fault-bend fold models. Our analysis shows that the modeled folds grow largely by parallel folding as specified by the kinematic theory; however, the process of folding over a broad axial surface zone yields a component of fold growth by limb rotation that is consistent with the patterns observed in natural folds. This result has important implications for how growth structures can he used to constrain slip and paleo-earthquake ages on active blind-thrust faults. In Chapter 2, we expand our DEM study to investigate the development of a wider range of fault-bend folds. We examine the influence of mechanical stratigraphy and quantitatively compare our models with the relationships between fold and fault shape prescribed by the kinematic theory. While the synclinal fault-bend models closely match the kinematic theory, the modeled anticlinal fault-bend folds show robust behavior that is distinct from the kinematic theory. Specifically, we observe that modeled structures maintain a linear relationship between fold shape (gamma) and fault-horizon cutoff angle (theta), rather than expressing the non-linear relationship with two distinct modes of anticlinal folding that is prescribed by the kinematic theory. These observations lead to a revised quantitative relationship for fault-bend folds that can serve as a useful interpretation tool. Finally, in Chapter 3, we examine the 3D relationships of tear- and thrust-fault systems in the western, deep-water Niger Delta. Using 3D seismic reflection data and new map-based structural restoration techniques, we find that the tear faults have distinct displacement patterns that distinguish them from conventional strike-slip faults and reflect their roles in accommodating displacement gradients within the fold-and-thrust belt.
Adiabatic Field-Free Alignment of Asymmetric Top Molecules with an Optical Centrifuge.
Korobenko, A; Milner, V
2016-05-06
We use an optical centrifuge to align asymmetric top SO_{2} molecules by adiabatically spinning their most polarizable O-O axis. The effective centrifugal potential in the rotating frame confines the sulfur atoms to the plane of the laser-induced rotation, leading to the planar molecular alignment that persists after the molecules are released from the centrifuge. The periodic appearance of the full three-dimensional alignment, typically observed only with linear and symmetric top molecules, is also detected. Together with strong in-plane centrifugal forces, which bend the molecules by up to 10 deg, permanent field-free alignment offers new ways of controlling molecules with laser light.
A polymer driveshaft for use in orbital and rotational atherectomy
NASA Astrophysics Data System (ADS)
Grothe, Preston Lee
Driveshafts used in atherectomy medical devices are often comprised of coiled or braided metal wires. These constructions are designed to tolerate delivery through tortuous vessels and can endure high speed rotation used during activation of the atherectomy treatment. This research investigated polymer driveshaft designs, which were comprised of polymer inner and outer layers, and coiled or braided stainless steel wires. The polymer driveshaft materials included polyimide, nylon 12, and polytetrafluoroethylene (PTFE). Mechanical testing of polymer driveshafts was conducted to determine material response in bending, tension, compression, and torsion. The polymer driveshaft test results were then compared with current coiled metal wire driveshaft constructions. The investigation identified polymer driveshaft options that could feasibly work in an atherectomy application.
Shaft flexibility effects on the forced response of a bladed-disk assembly
NASA Technical Reports Server (NTRS)
Khader, N.; Loewy, R. G.
1990-01-01
A model analysis approach is used to study the forced response of an actual flexible bladed-disk-shaft system. Both in-plane and out-of-plane flexible deformations of the bladed-disk assembly are considered, in addition to its rigid-body translations and rotations, resulting from the bending of the supporting flexible shaft in two orthogonal planes. The effects of Coriolis forces and structural coupling between flexible and rigid disk motions on the system's response are investigated. Aerodynamic loads acting on the rotating and vibrating bladed-disk assembly are accounted for through a simple quasi-steady representation, to evaluate their influence, combined with shaft flexibility and Coriolis effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, M.; Al-Dayeh, L.; Patel, P.
It is well known that even small movements of the head can lead to artifacts in fMRI. Corrections for these movements are usually made by a registration algorithm which accounts for translational and rotational motion of the head under a rigid body assumption. The brain, however, is not entirely rigid and images are prone to local deformations due to CSF motion, susceptibility effects, local changes in blood flow and inhomogeneities in the magnetic and gradient fields. Since nonrigid body motion is not adequately corrected by approaches relying on simple rotational and translational corrections, we have investigated a general approach wheremore » an n{sup th} order polynomial is used to map all images onto a common reference image. The coefficients of the polynomial transformation were determined through minimization of the ratio of the variance to the mean of each pixel. Simulation studies were conducted to validate the technique. Results of experimental studies using polynomial transformation for 2D and 3D registration show lower variance to mean ratio compared to simple rotational and translational corrections.« less
Ye, Jia; Gao, Yong
2012-01-01
Rotary instruments made of a new nickel-titanium (NiTi) alloy (M-Wire) have shown improved cyclic fatigue resistance and mechanical properties compared with those made of conventional superelastic NiTi wires. The objective of this study was to characterize microstructural changes of M-Wire throughout the cyclic fatigue process under controlled strain amplitude. The average fatigue life was calculated from 30 M-Wire samples that were subjected to a strain-controlled (≈ 4%) rotating bend fatigue test at room temperature and rotational speed of 300 rpm. Microstructural evolution of M-Wire has been investigated by different metallurgical characterization techniques, including differential scanning calorimetry, Vickers microhardness, and transmission electron microscopy at 4 different stages (as-received state, 30%, 60%, and 90% of average fatigue life). During rotating bend fatigue test, no statistically significant difference (P > .05) was found on austenite finish temperatures between as-received M-Wire and fatigued samples. However, significant differences (P < .05) were observed on Vickers microhardness for samples with 60% and 90% fatigue life compared with as-received and 30% fatigue life. Coincidentally, substantial growth of martensite grains and martensite twins was observed in microstructure under transmission electron microscopy after 60% fatigue life. The results of the present study suggested that endodontic instruments manufactured with M-Wire are expected to have higher strength and wear resistance than similar instruments made of conventional superelastic NiTi wires because of its unique nano-crystalline martensitic microstructure. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Strength of fixation constructs for basilar osteotomies of the first metatarsal.
Lian, G J; Markolf, K; Cracchiolo, A
1992-01-01
Twenty-four pairs of fresh-frozen human feet had a proximal osteotomy of the first metatarsal that was fixed using either screws, staples, or K wires. Each metatarsal was excised and the specimen was loaded to failure in a cantilever beam configuration by applying a superiorly directed force to the metatarsal head using an MTS servohydraulic test machine. Specimens with a crescentic osteotomy that were fixed using a single screw demonstrated higher mean failure moments than pairs that were fixed with four staples or two K wires; staples were the weakest construct. All specimens fixed with staples failed by bending of the staples without bony fracture; all K wire constructs but one failed by wire bending. Chevron and crescentic osteotomies fixed with a single screw demonstrated equal bending strengths; the bending strength of an oblique osteotomy fixed with two screws was 82% greater than for a crescentic osteotomy fixed with a single screw. Basilar osteotomies of the first metatarsal are useful in correcting metatarsus primus varus often associated with hallux valgus pathology. Fixation strength is an important consideration since weightbearing forces on the head of the first metatarsal acting at a distance from the osteotomy site subject the construct to a dorsiflexion bending moment, as simulated in our tests. Our results show that screw fixation is the strongest method for stabilizing a basilar osteotomy. Based upon the relatively low bending strengths of the staple and K wire constructs, we would not recommend these forms of fixation.(ABSTRACT TRUNCATED AT 250 WORDS)
Sudo, Hideki; Ito, Manabu; Abe, Yuichiro; Abumi, Kuniyoshi; Takahata, Masahiko; Nagahama, Ken; Hiratsuka, Shigeto; Kuroki, Kei; Iwasaki, Norimasa
2014-06-15
Retrospective analysis of a prospectively collected, consecutive, nonrandomized series of patients. To assess the surgical outcomes of the simultaneous double-rod rotation technique for treating Lenke 1 thoracic adolescent idiopathic scoliosis (AIS). With the increasing popularity of segmental pedicle screw spinal reconstruction for treating AIS, concerns regarding the limited ability to correct hypokyphosis have also increased. A consecutive series of 32 patients with Lenke 1 main thoracic AIS treated with the simultaneous double-rod rotation technique at our institution was included. Outcome measures included patient demographics, radiographical measurements, and Scoliosis Research Society questionnaire scores. All 32 patients were followed up for a minimum of 2 years (average, 3.6 yr). The average main thoracic Cobb angle correction rate and the correction loss at the final follow-up were 67.8% and 3.3°, respectively. The average preoperative thoracic kyphosis (T5-T12) was 11.9°, which improved significantly to 20.5° (P < 0.0001) at the final follow-up. An increase in thoracic kyphosis was significantly correlated with an increase in lumbar lordosis at the final follow-up (r = 0.42). The average preoperative vertebral rotation angle was 19.7°, which improved significantly after surgery to 14.9° (P = 0.0001). There was no correlation between change in thoracic kyphosis and change in apical vertebral rotation (r =-0.123). The average preoperative total Scoliosis Research Society questionnaire score was 3.0, which significantly improved to 4.4 (P < 0.0001) at the final follow-up. Throughout surgery and even after, there were no instrumentation failures, pseudarthrosis, infection of the surgical site, or clinically relevant neurovascular complications. The simultaneous double-rod rotation technique for treating Lenke 1 AIS provides significant sagittal correction of the main thoracic curve while maintaining sagittal profiles and correcting coronal and axial deformities. 4.
Bezci, Semih E; Klineberg, Eric O; O'Connell, Grace D
2018-01-01
The intervertebral disc is a complex joint that acts to support and transfer large multidirectional loads, including combinations of compression, tension, bending, and torsion. Direct comparison of disc torsion mechanics across studies has been difficult, due to differences in loading protocols. In particular, the lack of information on the combined effect of multiple parameters, including axial compressive preload and rotation angle, makes it difficult to discern whether disc torsion mechanics are sensitive to the variables used in the test protocol. Thus, the objective of this study was to evaluate compression-torsion mechanical behavior of healthy discs under a wide range of rotation angles. Bovine caudal discs were tested under a range of compressive preloads (150, 300, 600, and 900N) and rotation angles (± 1, 2, 3, 4, or 5°) applied at a rate of 0.5°/s. Torque-rotation data were used to characterize shape changes in the hysteresis loop and to calculate disc torsion mechanics. Torsional mechanical properties were described using multivariate regression models. The rate of change in torsional mechanical properties with compression depended on the maximum rotation angle applied, indicating a strong interaction between compressive stress and maximum rotation angle. The regression models reported here can be used to predict disc torsion mechanics under axial compression for a given disc geometry, compressive preload, and rotation angle. Copyright © 2017 Elsevier Ltd. All rights reserved.
Piston pump and method of reducing vapor lock
Phillips, Benjamin A.; Harvey, Michael N.
2000-02-15
A pump includes a housing defining a cavity, at least one bore, a bore inlet, and a bore outlet. The bore extends from the cavity to the outlet and the inlet communicates with the bore at a position between the cavity and the outlet. A crankshaft is mounted in supports and has an eccentric portion disposed in the cavity. The eccentric portion is coupled to a piston so that rotation of the crankshaft reciprocates the piston in the bore between a discharge position an intake position. The bore may be offset from an axis of rotation to reduce bending of the piston during crankshaft rotation. During assembly of the pump, separate parts of the housing can be connected together to facilitate installation of internal pumping components. Also disclosed is a method of reducing vapor lock by mixing vapor and liquid portions of a substance and introducing the mixture into a piston bore.
Piston pump and method of reducing vapor lock
Phillips, Benjamin A.; Harvey, Michael N.
2001-01-30
A pump includes a housing defining a cavity, at least one bore, a bore inlet, and a bore outlet. The bore extends from the cavity to the outlet and the inlet communicates with the bore at a position between the cavity and the outlet. A crankshaft is mounted in supports and has an eccentric portion disposed in the cavity. The eccentric portion is coupled to a piston so that rotation of the crankshaft reciprocates the piston in the bore between a discharge position an intake position. The bore may be offset from an axis of rotation to reduce bending of the piston during crankshaft rotation. During assembly of the pump, separate parts of the housing can be connected together to facilitate installation of internal pumping components. Also disclosed is a method of reducing vapor lock by mixing vapor and liquid portions of a substance and introducing the mixture into a piston bore.
Human sperm steer with second harmonics of the flagellar beat.
Saggiorato, Guglielmo; Alvarez, Luis; Jikeli, Jan F; Kaupp, U Benjamin; Gompper, Gerhard; Elgeti, Jens
2017-11-10
Sperm are propelled by bending waves traveling along their flagellum. For steering in gradients of sensory cues, sperm adjust the flagellar waveform. Symmetric and asymmetric waveforms result in straight and curved swimming paths, respectively. Two mechanisms causing spatially asymmetric waveforms have been proposed: an average flagellar curvature and buckling. We image flagella of human sperm tethered with the head to a surface. The waveform is characterized by a fundamental beat frequency and its second harmonic. The superposition of harmonics breaks the beat symmetry temporally rather than spatially. As a result, sperm rotate around the tethering point. The rotation velocity is determined by the second-harmonic amplitude and phase. Stimulation with the female sex hormone progesterone enhances the second-harmonic contribution and, thereby, modulates sperm rotation. Higher beat frequency components exist in other flagellated cells; therefore, this steering mechanism might be widespread and could inspire the design of synthetic microswimmers.
Turbine blade and non-integral platform with pin attachment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, Christian X; Eng, Darryl; Marra, John J
Platforms (36, 38) span between turbine blades (23, 24, 25) on a disk (32). Each platform may be individually mounted to the disk by a pin attachment (42). Each platform (36) may have a rotationally rearward edge portion (50) that underlies a forward portion (45) of the adjacent platform (38). This limits centrifugal bending of the rearward portion of the platform, and provides coolant sealing. The rotationally forward edge (44A, 44B) of the platform overlies a seal element (51) on the pressure side (28) of the forwardly adjacent blade, and does not underlie a shelf on that blade. The pinmore » attachment allows radial mounting of each platform onto the disk via tilting (60) of the platform during mounting to provide mounting clearance for the rotationally rearward edge portion (50). This facilitates quick platform replacement without blade removal.« less
Finite Rotation Analysis of Highly Thin and Flexible Structures
NASA Technical Reports Server (NTRS)
Clarke, Greg V.; Lee, Keejoo; Lee, Sung W.; Broduer, Stephen J. (Technical Monitor)
2001-01-01
Deployable space structures such as sunshields and solar sails are extremely thin and highly flexible with limited bending rigidity. For analytical investigation of their responses during deployment and operation in space, these structures can be modeled as thin shells. The present work examines the applicability of the solid shell element formulation to modeling of deployable space structures. The solid shell element formulation that models a shell as a three-dimensional solid is convenient in that no rotational parameters are needed for the description of kinematics of deformation. However, shell elements may suffer from element locking as the thickness becomes smaller unless special care is taken. It is shown that, when combined with the assumed strain formulation, the solid shell element formulation results in finite element models that are free of locking even for extremely thin structures. Accordingly, they can be used for analysis of highly flexible space structures undergoing geometrically nonlinear finite rotations.
Turbine blade and non-integral platform with pin attachment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, Christian Xavier; Eng, Darryl; Marra, John J.
2016-08-02
Platforms (36, 38) span between turbine blades (23, 24, 25) on a disk (32). Each platform may be individually mounted to the disk by a pin attachment (42). Each platform (36) may have a rotationally rearward edge portion (50) that underlies a forward portion (45) of the adjacent platform (38). This limits centrifugal bending of the rearward portion of the platform, and provides coolant sealing. The rotationally forward edge (44A, 44B) of the platform overlies a seal element (51) on the pressure side (28) of the forwardly adjacent blade, and does not underlie a shelf on that blade. The pinmore » attachment allows radial mounting of each platform onto the disk via tilting (60) of the platform during mounting to provide mounting clearance for the rotationally rearward edge portion (50). This facilitates quick platform replacement without blade removal.« less
Structure and conformational states of the bovine mitochondrial ATP synthase by cryo-EM.
Zhou, Anna; Rohou, Alexis; Schep, Daniel G; Bason, John V; Montgomery, Martin G; Walker, John E; Grigorieff, Nikolaus; Rubinstein, John L
2015-10-06
Adenosine triphosphate (ATP), the chemical energy currency of biology, is synthesized in eukaryotic cells primarily by the mitochondrial ATP synthase. ATP synthases operate by a rotary catalytic mechanism where proton translocation through the membrane-inserted FO region is coupled to ATP synthesis in the catalytic F1 region via rotation of a central rotor subcomplex. We report here single particle electron cryomicroscopy (cryo-EM) analysis of the bovine mitochondrial ATP synthase. Combining cryo-EM data with bioinformatic analysis allowed us to determine the fold of the a subunit, suggesting a proton translocation path through the FO region that involves both the a and b subunits. 3D classification of images revealed seven distinct states of the enzyme that show different modes of bending and twisting in the intact ATP synthase. Rotational fluctuations of the c8-ring within the FO region support a Brownian ratchet mechanism for proton-translocation-driven rotation in ATP synthases.
Viana, A C D; Pereira, E S J; Bahia, M G A; Buono, V T L
2013-09-01
To investigate the influence of cyclic flexural and torsional loading on the flexibility of ProTaper Universal, K3 and EndoSequence nickel-titanium instruments, in view of the hypothesis that these types of loading would decrease the flexibility of the selected NiTi rotary files. The instruments evaluated were S2 and F1 ProTaper Universal, sizes 20 and 25, .06 taper K3, and sizes 20 and 25, .06 taper EndoSequence. Flexibility was determined by 45° bending tests according to ISO 3630-1 specification. Values of the bending moment (MB ) obtained with new instruments were considered as the control group (CG). Bending tests were then conducted in instruments previously fatigued to one-fourth and three-fourths of their average fatigue life (fatigue groups, FG¼ and FG¾), as well as after cyclic torsional loading (torsional group, TG). Fatigue tests were carried out in a bench device that allowed the files to rotate freely inside an artificial canal with an angle of curvature of 45° and a radius of 5 mm. Cyclic torsional loading tests were performed that entailed rotating the instrument from zero angular deflection to 180° and then returning to zero applied torque in 20 cycles. Data were analysed using one-way analysis of variance at a significance level of 5%. Simulated clinical use by means of flexural fatigue tests did not affect the flexibility of the instruments, except for a significant increase in flexibility observed in a few instruments (P < 0.05). In addition, comparative statistical analyses between the values of MB measured in new instruments and after cyclic torsional loading showed no significant differences between them (P > 0.05). The flexibility of rotary ProTaper Universal, K3 and EndoSequence NiTi instruments, measured in bending tests, was not adversely affected by simulated clinical use in curved root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Nowroozi, B N; Brainerd, E L
2013-08-01
Whole-body stiffness has a substantial impact on propulsive wave speed during axial undulatory locomotion in fishes. The connective tissues of the vertebral column may contribute to body stiffness, but without mechanical and kinematic analysis it is unclear whether the in vivo range of motion of intervertebral joints (IVJs) is great enough to stress IVJ tissues, thus generating stiffness. The present study used 2D videoradiography and 3D X-ray reconstruction of moving morphology (XROMM) to quantify vertebral kinematics during the startle response in striped bass (Morone saxatilis). X-ray video revealed two distinct patterns of bending: pattern I begins in the abdominal region and then proceeds to maximum IVJ angles in the caudal region, whereas pattern II begins in the cervical region and proceeds to maximum IVJ angles in the abdominal and then the caudal joints. In pattern II bends, the cervical joints exhibit a greater in vivo range of motion than previously reported in other species. XROMM analysis of caudal IVJs suggests primarily lateral bending: mean axial and dorsoventral rotations were less than 2 deg and inconsistent across 51 sequences analyzed from five individuals, whereas mean maximum lateral bending angles were 10.4±3.57 deg. These angles, combined with previous investigations of mechanical properties, reveal that the maximum angles all occur within the neutral zone of bending, indicating that little stress is experienced about the joint. This suggests that the IVJs of striped bass are quite compliant and likely do not contribute significantly to whole-body stiffness or elastic recoil during swimming in vivo.
2013-09-01
35 2. Signal Rotator .....................................................................................37 1...37 Figure 18. The implementation of a clockwise rotator for phase error correction. ...........39 Figure... rotation by carrier phase/frequency synchronization circuit. .........................................................41 Figure 21. Output of the phase
Differential transfer processes in incremental visuomotor adaptation.
Seidler, Rachel D
2005-01-01
Visuomotor adaptive processes were examined by testing transfer of adaptation between similar conditions. Participants made manual aiming movements with a joystick to hit targets on a computer screen, with real-time feedback display of their movement. They adapted to three different rotations of the display in a sequential fashion, with a return to baseline display conditions between rotations. Adaptation was better when participants had prior adaptive experiences. When performance was assessed using direction error (calculated at the time of peak velocity) and initial endpoint error (error before any overt corrective actions), transfer was greater when the final rotation reflected an addition of previously experienced rotations (adaptation order 30 degrees rotation, 15 degrees, 45 degrees) than when it was a subtraction of previously experienced conditions (adaptation order 45 degrees rotation, 15 degrees, 30 degrees). Transfer was equal regardless of adaptation order when performance was assessed with final endpoint error (error following any discrete, corrective actions). These results imply the existence of multiple independent processes in visuomotor adaptation.
Robert H. McAlister; Alexander Clark; Joseph R. Saucier
1997-01-01
The effect of rotation age on strength and stiffness of lumber produced from unthinned loblolly pine stands in the Coastal Plain of Georgia was examined. Six stands representing 22-, 28-, and 40-year-old roations were sampled. A stratified random sample of trees 8 to 16 inches in diameter at breast height was selected from each stand and processed into lumber....
NASA Astrophysics Data System (ADS)
Salem, Mohamed; Fazzini, Marina; Ouagne, Pierre
2018-02-01
During the complex shape forming of composite fibrous reinforcement, the planar bending of roving tows results in an out-of-plane deflection, along with a rotation on its central axis. The need to accurately follow and quantify the mechanism of formation of such defect has led us to consider two 3D imaging techniques, of which, have been tested and compared in this work.
Influence of Surface Roughness on the Fatigue Life of Nickel-Titanium Rotary Endodontic Instruments.
Lopes, Hélio P; Elias, Carlos N; Vieira, Márcia V B; Vieira, Victor T L; de Souza, Letícia Chaves; Dos Santos, Alexander Lopes
2016-06-01
The goal of the present study was to evaluate the influence of surface grooves (peaks and valleys) resulting from machining during the manufacturing process of polished and unpolished nickel-titanium BR4C endodontic files on the fatigue life of the instruments. Ten electropolished and 10 unpolished endodontic files were provided by the manufacturer. Specimens were from the same batch, but the unpolished instruments were removed from the production line before surface treatment. The instruments were evaluated with a profilometer to quantify the surface roughness on the working part of the instruments. Then the files were subjected to rotating bending fatigue tests. Analysis with the profilometer showed that surface grooves were deeper on the unpolished instruments compared with their electropolished counterparts. In the rotating bending fatigue test, the mean and standard deviation for the number of cycles until fracture (NCF) were greater for instruments with less pronounced grooves. Student t test revealed significant differences in all tests (P < .05). The results from the present study showed that the depth of the surface grooves on the working part affected the NCF of the instruments tested; the smaller the groove depth, the greater the NCF. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Hu, Yong; Dong, Wei-Xin; Hann, Shannon; Yuan, Zhen-Shan; Sun, Xiao-Yang; Xie, Hui; Zhang, Meichao
To investigate the stress distribution on artificial atlantoaxial-odontoid joint (AAOJ) components during flexion, extension, lateral bending and rotation of AAOJ model constructed with the finite element (FE) method. Human cadaver specimens of normal AAOJ were CT scanned with 1 mm -thickness and transferred into Mimics software to reconstruct the three-dimensional models of AAOJ. These data were imported into Freeform software to place a AAOJ into a atlantoaxial model. With Ansys software, a geometric model of AAOJ was built. Perpendicular downward pressure of 40 N was applied to simulate gravity of a skull, then 1.53 N• m torque was exerted separately to simulate the range of motion of the model. An FE model of atlantoaxial joint after AAOJ replacement was constructed with a total of 103 053 units and 26 324 nodes. In flexion, extension, right lateral bending and right rotation, the AAOJ displacement was 1.109 mm, 3.31 mm, 0.528 mm, and 9.678 mm, respectively, and the range of motion was 1.6°, 5.1°, 4.6° and 22°. During all ROM, stress distribution of atlas-axis changed after AAOJ replacement indicating that AAOJ can offload stress. The stress distribution in the AAOJ can be successfully analyzed with the FE method.
Parametric analysis of occupant ankle and tibia injuries in frontal impact
Mo, Fuhao; Jiang, Xiaoqing; Duan, Shuyong; Xiao, Zhi; Shi, Wei
2017-01-01
Objective Non-fatal tibia and ankle injuries without proper protection from the restraint system has gotten wide attention from researchers. This study aimed to investigate occupant tibia and ankle injuries under realistic frontal impact environment that is rarely considered in previous experimental and simulant studies. Methods An integrated occupant-vehicle model was established by coupling an isolated car cab model and a hybrid occupant model with a biofidelic pelvis-lower limb model, while its loading conditions were extracted from the realistic full-frontal impact test. A parametric study was implemented concerning instrument panel (IP) design and pedal intrusion/rotation parameters. Results The significant influences of the IP angle, pedal intrusion and pedal rotation on tibia axial force, tibia bending moment and ankle dorsiflexion angle are noted. By coupling their effects, a new evaluation index named CAIEI (Combined Ankle Injury Evaluation Index) is established to evaluate ankle injury (including tibia fractures in ankle region) risk and severity in robustness. Conclusions Overall results and analysis indicate that ankle dorsiflexion angle should be considered when judging the injury in lower limb under frontal impact. Meanwhile, the current index with coupling effects of tibia axial force, bending moment and ankle dorsiflexion angle is in a good correlation with the simulation injury outcomes. PMID:28910377
NASA Technical Reports Server (NTRS)
Meissner, Thomas; Wentz, Frank J.
2006-01-01
The third Stokes parameter of ocean surface brightness temperatures measured by the WindSat instrument is sensitive to the rotation angle between the polarization vectors at the ocean surface and the instrument. This rotation angle depends on the spacecraft attitude (roll, pitch, yaw) as well as the Faraday rotation of the electromagnetic radiation passing through the Earth's ionosphere. Analyzing the WindSat antenna temperatures, we find biases in the third Stokes parameter as function of the along-scan position of up to 1.5 K in all feedhorns. This points to a misspecification of the reported spacecraft attitude. A single attitude correction of -0.16deg roll and 0.18deg pitch for the whole instrument eliminates all the biases. We also study the effect of Faraday rotation at 10.7 GHz on the accuracy of the third Stokes parameter and the sea surface wind direction retrieval and demonstrate how this error can be corrected using values from the International Reference Ionosphere for the total electron content when computing Faraday rotation.
Robotic Arm Comprising Two Bending Segments
NASA Technical Reports Server (NTRS)
Mehling, Joshua S.; Difler, Myron A.; Ambrose, Robert O.; Chu, Mars W.; Valvo, Michael C.
2010-01-01
The figure shows several aspects of an experimental robotic manipulator that includes a housing from which protrudes a tendril- or tentacle-like arm 1 cm thick and 1 m long. The arm consists of two collinear segments, each of which can be bent independently of the other, and the two segments can be bent simultaneously in different planes. The arm can be retracted to a minimum length or extended by any desired amount up to its full length. The arm can also be made to rotate about its own longitudinal axis. Some prior experimental robotic manipulators include single-segment bendable arms. Those arms are thicker and shorter than the present one. The present robotic manipulator serves as a prototype of future manipulators that, by virtue of the slenderness and multiple- bending capability of their arms, are expected to have sufficient dexterity for operation within spaces that would otherwise be inaccessible. Such manipulators could be especially well suited as means of minimally invasive inspection during construction and maintenance activities. Each of the two collinear bending arm segments is further subdivided into a series of collinear extension- and compression-type helical springs joined by threaded links. The extension springs occupy the majority of the length of the arm and engage passively in bending. The compression springs are used for actively controlled bending. Bending is effected by means of pairs of antagonistic tendons in the form of spectra gel spun polymer lines that are attached at specific threaded links and run the entire length of the arm inside the spring helix from the attachment links to motor-driven pulleys inside the housing. Two pairs of tendons, mounted in orthogonal planes that intersect along the longitudinal axis, are used to effect bending of each segment. The tendons for actuating the distal bending segment are in planes offset by an angle of 45 from those of the proximal bending segment: This configuration makes it possible to accommodate all eight tendons at the same diameter along the arm. The threaded links have central bores through which power and video wires can be strung (1) from a charge-coupled-device camera mounted on the tip of the arms (2) back along the interior of the arm into the housing and then (3) from within the housing to an external video monitor.
Dibb, Alan T; Nightingale, Roger W; Chancey, V Carol; Fronheiser, Lucy E; Tran, Laura; Ottaviano, Danielle; Meyers, Barry S
2006-11-01
This study evaluated the biofidelity of both the Hybrid III and the THOR-NT anthropomorphic test device (ATD) necks in quasistatic tension-bending and pure-bending by comparing the responses of both the ATDs with results from validated computational models of the living human neck. This model was developed using post-mortem human surrogate (PMHS) osteoligamentous response corridors with effective musculature added (Chancey, 2005). Each ATD was tested using a variety of end-conditions to create the tension-bending loads. The results were compared using absolute difference, RMS difference, and normalized difference metrics. The THOR-NT was tested both with and without muscle cables. The THOR-NT was also tested with and without the central safety cable to test the effect of the cable on the behavior of the ATD. The Hybrid III was stiffer than the model for all tension-bending end conditions. Quantitative measurement of the differences in response showed more close agreement between the THOR-NT and the model than the Hybrid III and the model. By contrast, no systematic differences were observed in the head kinematics. The muscle cables significantly stiffened the THOR-NT by effectively reducing the laxity from the occipital condyle (OC) joint. The cables also shielded the OC upper neck load cell from a significant portion of the applied loads. The center safety significantly stiffened the response and decreased the fidelity, particularly in modes of loading in which tensile forces were large and bending moments small. This study compares ATD responses to computational models in which the models include PMHS response corridors while correcting for problems associated with cadaveric muscle. While controversial and requiring considerable diligence, these kinds of approaches show promise in assessing ATD biofidelity.
Unexpected angular or rotational deformity after corrective osteotomy
2014-01-01
Background Codman’s paradox reveals a misunderstanding of geometry in orthopedic practice. Physicians often encounter situations that cannot be understood intuitively during orthopedic interventions such as corrective osteotomy. Occasionally, unexpected angular or rotational deformity occurs during surgery. This study aimed to draw the attention of orthopedic surgeons toward the concepts of orientation and rotation and demonstrate the potential for unexpected deformity after orthopedic interventions. This study focused on three situations: shoulder arthrodesis, femoral varization derotational osteotomy, and femoral derotation osteotomy. Methods First, a shoulder model was generated to calculate unexpected rotational deformity to demonstrate Codman’s paradox. Second, femoral varization derotational osteotomy was simulated using a cylinder model. Third, a reconstructed femoral model was used to calculate unexpected angular or rotational deformity during femoral derotation osteotomy. Results Unexpected external rotation was found after forward elevation and abduction of the shoulder joint. In the varization and derotation model, closed-wedge osteotomy and additional derotation resulted in an unexpected extension and valgus deformity, namely, under-correction of coxa valga. After femoral derotational osteotomy, varization and extension of the distal fragment occurred, although the extension was negligible. Conclusions Surgeons should be aware of unexpected angular deformity after surgical procedure involving bony areas. The degree of deformity differs depending on the context of the surgical procedure. However, this study reveals that notable deformities can be expected during orthopedic procedures such as femoral varization derotational osteotomy. PMID:24886469
Compact adaptive optic-optical coherence tomography system
Olivier, Scot S [Livermore, CA; Chen, Diana C [Fremont, CA; Jones, Steven M [Danville, CA; McNary, Sean M [Stockton, CA
2012-02-28
Badal Optometer and rotating cylinders are inserted in the AO-OCT to correct large spectacle aberrations such as myopia, hyperopic and astigmatism for ease of clinical use and reduction. Spherical mirrors in the sets of the telescope are rotated orthogonally to reduce aberrations and beam displacement caused by the scanners. This produces greatly reduced AO registration errors and improved AO performance to enable high order aberration correction in a patient eyes.
Compact adaptive optic-optical coherence tomography system
Olivier, Scot S [Livermore, CA; Chen, Diana C [Fremont, CA; Jones, Steven M [Danville, CA; McNary, Sean M [Stockton, CA
2011-05-17
Badal Optometer and rotating cylinders are inserted in the AO-OCT to correct large spectacle aberrations such as myopia, hyperopic and astigmatism for ease of clinical use and reduction. Spherical mirrors in the sets of the telescope are rotated orthogonally to reduce aberrations and beam displacement caused by the scanners. This produces greatly reduced AO registration errors and improved AO performance to enable high order aberration correction in a patient eyes.
NASA Technical Reports Server (NTRS)
Fleming, Gary A.; Soto, Hector L.; South, Bruce W.
2002-01-01
Projection Moire Interferometry (PMI) has been used during wind tunnel tests to obtain azimuthally dependent blade bending and twist measurements for a 4-bladed Active Twist Rotor (ATR) system in simulated forward flight. The ATR concept offers a means to reduce rotor vibratory loads and noise by using piezoelectric active fiber composite actuators embedded in the blade structure to twist each blade as they rotate throughout the rotor azimuth. The twist imparted on the blades for blade control causes significant changes in blade loading, resulting in complex blade deformation consisting of coupled bending and twist. Measurement of this blade deformation is critical in understanding the overall behavior of the ATR system and the physical mechanisms causing the reduction in rotor loads and noise. PMI is a non-contacting, video-based optical measurement technique capable of obtaining spatially continuous structural deformation measurements over the entire object surface within the PMI system field-of-view. When applied to rotorcraft testing, PMI can be used to measure the azimuth-dependent blade bending and twist along the full span of the rotor blade. This paper presents the PMI technique as applied to rotorcraft testing, and provides results obtained during the ATR tests demonstrating the PMI system performance. PMI measurements acquired at select blade actuation conditions generating minimum and maximum rotor loads are provided to explore the interrelationship between rotor loads, blade bending, and twist.
NASA Astrophysics Data System (ADS)
Vila, Paloma; Baeza, Luis; Martínez-Casas, José; Carballeira, Javier
2014-05-01
In this work, a simulation tool is developed to analyse the growth of rail corrugation consisting of several models connected in a feedback loop in order to account for both the short-term dynamic vehicle-track interaction and the long-term damage. The time-domain vehicle-track interaction model comprises a flexible rotating wheel set model, a cyclic track model based on a substructuring technique and a non-Hertzian and non-steady-state three-dimensional wheel-rail contact model, based on the variational theory by Kalker. Wear calculation is performed with Archard's wear model by using the contact parameters obtained with the non-Hertzian and non-steady-state three-dimensional contact model. The aim of this paper is to analyse the influence of the excitation of two coinciding resonances of the flexible rotating wheel set on the rail corrugation growth in the frequency range from 20 to 1500 Hz, when contact conditions similar to those that can arise while a wheel set is negotiating a gentle curve are simulated. Numerical results show that rail corrugation grows only on the low rail for two cases in which two different modes of the rotating wheel set coincide in frequency. In the first case, identified by using the Campbell diagram, the excitation of both the backward wheel mode and the forward third bending mode of the wheel set model (B-F modes) promotes the growth of rail corrugation with a wavelength of 110 mm for a vehicle velocity of 142 km/h. In the second case, the excitation of both the backward wheel mode and the backward third bending mode (B-B modes) gives rise to rail corrugation growth at a wavelength of 156 mm when the vehicle velocity is 198 km/h.
NASA Astrophysics Data System (ADS)
Xu, Yuntao; Xiong, Bo; Chang, Yih Chung; Ng, C. Y.
2013-07-01
By employing the newly established vacuum ultraviolet (VUV) laser pulsed field ionization-photoion (PFI-PI) double quadrupole-double octopole ion guide apparatus, we have examined the translational, rotational, and vibrational energy effects on the chemical reactivity of water cation H2O+(X2B1) in the collision with deuterium molecule D2. The application of a novel electric-field pulsing scheme to the VUV laser PFI-PI ion source has enabled the preparation of a rovibrationally selected H2O+(X2B1; v_1^ + v_2^ + v_3^ +; N+Ka+Kc+) ion beam with not only high internal-state selectivity and high intensity but also high translational energy resolution. Despite the unfavorable Franck-Condon factors, we are able to prepare the excited vibrational states (v_1^ + v_2^ + v_3^ +) = (100) and (020) along with the (000) ground vibrational state, for collisional studies, where v_1^ +, v_2^ +, and v_3^ + represent the symmetric stretching, bending, and asymmetric stretching modes of H2O+(X2B1). We show that a range of rotational levels from N+Ka+Kc+ = 000 to 322, covering a rotational energy range of 0-200 cm-1 of these vibrational states, can also be generated for absolute integral cross section (σ) measurements at center-of-mass collision energies (Ecms) from thermal energies to 10.00 eV. The Ecm dependences of the σ values are consistent with the prediction of the orbiting model, indicating that translational energy significantly hinders the chemical reactivity of H2O+(X2B1). Rotational enhancements are observed at Ecm < 0.30 eV for all the three vibrational states, (000), (100), and (020). While the σ values for (100) are found to be only slightly below those for (000), the σ values for (020) are lower than those for (000) and (100) by up to 20% at Ecm ≤ 0.20 eV, indicative of vibrational inhibition at low Ecm by excitation of the (020) mode. Rationalizations are proposed for the observed rotational enhancements and the bending vibrational inhibition. Rigorous theoretical calculations are needed to interpret the wealth of rovibrationally selected cross sections obtained in the present study.
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Braun, M. J.; Mullen, R. L.; Burcham, R. E.; Diamond, W. A.
1985-01-01
High-pressure, high-temperature seal flow (leakage) data for nonrotating and rotating Raleigh-step and convergent-tapered-bore seals were characterized in terms of a normalized flow coefficient. The data for normalized Rayleigh-steip and nonrotating tapered-bore seals were in reasonable agreement with theory, but data for the rotating tapered-bore seals were not. The tapered-bore-seal operational clearances estimated from the flow data were significantly larger than calculated. Although clearances are influenced by wear from conical to cylindrical geometry and errors in clearance corrections, the problem was isolated to the shaft temperature - rotational speed clearance correction. The geometric changes support the use of some conical convergence in any seal. Under these conditions rotation reduced the normalized flow coefficiently by nearly 10 percent.
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Mullen, R. L.; Braun, M. J.; Burcham, R. E.; Diamond, W. A.
1987-01-01
High-pressure, high-temperature seal flow (leakage) data for nonrotating and rotating Raleigh-step and convergent-tapered-bore seals were characterized in terms of a normalized flow coefficient. The data for normalized Rayleigh-step and nonrotating tapered-bore seals were in reasonable agreement with theory, but data for the rotating tapered-bore seals were not. The tapered-bore-seal operational clearances estimated from the flow data were significantly larger than calculated. Although clearances are influenced by wear from conical to cylindrical geometry and errors in clearance corrections, the problem was isolated to the shaft temperature - rotational speed clearance correction. The geometric changes support the use of some conical convergence in any seal. Under these conditions rotation reduced the normalized flow coefficiently by nearly 10 percent.
Quantum gravity effects on scalar particle tunneling from rotating BTZ black hole
NASA Astrophysics Data System (ADS)
Meitei, I. Ablu; Singh, T. Ibungochouba; Devi, S. Gayatri; Devi, N. Premeshwari; Singh, K. Yugindro
2018-04-01
Tunneling of scalar particles across the event horizon of rotating BTZ black hole is investigated using the Generalized Uncertainty Principle to study the corrected Hawking temperature and entropy in the presence of quantum gravity effects. We have determined explicitly the various correction terms in the entropy of rotating BTZ black hole including the logarithmic term of the Bekenstein-Hawking entropy (SBH), the inverse term of SBH and terms with inverse powers of SBH, in terms of properties of the black hole and the emitted particles — mass, energy and angular momentum. In the presence of quantum gravity effects, for the emission of scalar particles, the Hawking radiation and thermodynamics of rotating BTZ black hole are observed to be related to the metric element, hence to the curvature of space-time.
The importance of cantilever dynamics in the interpretation of Kelvin probe force microscopy.
Satzinger, Kevin J; Brown, Keith A; Westervelt, Robert M
2012-09-15
A realistic interpretation of the measured contact potential difference (CPD) in Kelvin probe force microscopy (KPFM) is crucial in order to extract meaningful information about the sample. Central to this interpretation is a method to include contributions from the macroscopic cantilever arm, as well as the cone and sharp tip of a KPFM probe. Here, three models of the electrostatic interaction between a KPFM probe and a sample are tested through an electrostatic simulation and compared with experiment. In contrast with previous studies that treat the KPFM cantilever as a rigid object, we allow the cantilever to bend and rotate; accounting for cantilever bending provides the closest agreement between theory and experiment. We demonstrate that cantilever dynamics play a major role in CPD measurements and provide a simulation technique to explore this phenomenon.
Vertebral derotation in adolescent idiopathic scoliosis causes hypokyphosis of the thoracic spine
2012-01-01
Background The purpose of this study was to test the hypothesis that direct vertebral derotation by pedicle screws (PS) causes hypokyphosis of the thoracic spine in adolescent idiopathic scoliosis (AIS) patients, using computer simulation. Methods Twenty AIS patients with Lenke type 1 or 2 who underwent posterior correction surgeries using PS were included in this study. Simulated corrections of each patient’s scoliosis, as determined by the preoperative CT scan data, were performed on segmented 3D models of the whole spine. Two types of simulated extreme correction were performed: 1) complete coronal correction only (C method) and 2) complete coronal correction with complete derotation of vertebral bodies (C + D method). The kyphosis angle (T5-T12) and vertebral rotation angle at the apex were measured before and after the simulated corrections. Results The mean kyphosis angle after the C + D method was significantly smaller than that after the C method (2.7 ± 10.0° vs. 15.0 ± 7.1°, p < 0.01). The mean preoperative apical rotation angle of 15.2 ± 5.5° was completely corrected after the C + D method (0°) and was unchanged after the C method (17.6 ± 4.2°). Conclusions In the 3D simulation study, kyphosis was reduced after complete correction of the coronal and rotational deformity, but it was maintained after the coronal-only correction. These results proved the hypothesis that the vertebral derotation obtained by PS causes hypokyphosis of the thoracic spine. PMID:22691717
Hawking radiation of scalar particles from accelerating and rotating black holes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gillani, Usman A.; Rehman, Mudassar; Saifullah, K., E-mail: mani_precious2001@yahoo.com, E-mail: mudassar051@yahoo.com, E-mail: saifullah@qau.edu.pk
2011-06-01
Hawking radiation of uncharged and charged scalar particles from accelerating and rotating black holes is studied. We calculate the tunneling probabilities of these particles from the rotation and acceleration horizons of these black holes. Using this method we recover the correct Hawking temperature as well.
NASA Technical Reports Server (NTRS)
Le Vine, David
2016-01-01
Faraday rotation is a change in the polarization as signal propagates through the ionosphere. At L-band it is necessary to correct for this change and measurements are made on the spacecraft of the rotation angle. These figures show that there is good agreement between the SMAP measurements (blue) and predictions based on models (red).
Bootstrapping Confidence Intervals for Robust Measures of Association.
ERIC Educational Resources Information Center
King, Jason E.
A Monte Carlo simulation study was conducted to determine the bootstrap correction formula yielding the most accurate confidence intervals for robust measures of association. Confidence intervals were generated via the percentile, adjusted, BC, and BC(a) bootstrap procedures and applied to the Winsorized, percentage bend, and Pearson correlation…
Hey, Hwee Weng Dennis; Lau, Eugene Tze-Chun; Tan, Kimberly-Anne; Lim, Joel L; Choong, Denise; Lau, Leok-Lim; Liu, Ka-Po G; Wong, Hee-Kit
2017-10-01
A cross-sectional study of prospectively collected data. To compare lumbar spine alignment in six common postures, and estimate loss in range of motion (ROM) relative to standing. Ideal position for fusion of lumbar spine remains unknown. Although surgical fusion is necessary for deformity correction and symptom relief, the final position in which the vertebrae are immobilized should provide maximum residual function. Data were collected prospectively from 70 patients with low back pain recruited over a year. All subjects had x-rays performed in slump sitting, forward bending, supine, half squatting, standing, and backward bending postures. ROM quantified in terms of sagittal global and segmental Cobb angles was measured from L1 to S1. Loss of ROM relative to standing was calculated for each posture. Analysis of variance and unpaired t tests were used to identify differences in alignment between postures. Slump sitting gives the greatest lumbar flexion followed by forward bending, and supine postures (P < 0.001). Backward bending produces greater lumbar extension than standing (P = 0.035). Half-squatting and standing postures were not significantly different (P = 0.938). For all postures, L4-5 and L5-S1 segments remained in lordosis, with L4-5 having greater ROM than L5-S1. L1-2 turns kyphotic in lying supine, L2-3 at forward bending, and L3-4 at slump sitting in the form of a "kyphosing cascade." Should the entire lumbar spine be fused in standing position from L1-S1, there would likely be a mean loss of 47.6° of lumbar flexion and 5.9° of lumbar extension. The present study demonstrates the extent of flexibility required of the lumbar spine in assuming various postures. It also enables comparison of the differences in degree of motion occurring in the lumbar spine, both across postures and across segments. Significant loss in ROM, particularly flexion, is anticipated with fusion modeled after the lordotic standing lumbar spine. 2.
Trainor, Kate; Pinnington, Mark A
2011-03-01
It has been proposed that neurodynamic examination can assist differential diagnosis of upper/mid lumbar nerve root compression; however, the diagnostic validity of many of these tests has yet to be established. This pilot study aimed to establish the diagnostic validity of the slump knee bend neurodynamic test for upper/mid lumbar nerve root compression in subjects with suspected lumbosacral radicular pain. Two independent examiners performed the slump knee bend test on subjects with radicular leg pain. Inter-tester reliability was calculated using the kappa coefficient. Slump knee bend test results were compared with magnetic resonance imaging findings, and diagnostic accuracy measures were calculated including sensitivity, specificity, predictive values and likelihood ratios. Orthopaedic spinal clinic, secondary care. Sixteen patients with radicular leg pain. All four subjects with mid lumbar nerve root compression on magnetic resonance imaging were correctly identified with the slump knee bend test; however, it was falsely positive in two individuals without the condition. Inter-tester reliability for the slump knee bend test using the kappa coefficient was 0.71 (95% confidence interval 0.33 to 1.0). Diagnostic validity calculations for the slump knee bend test (95% confidence intervals) were: sensitivity, 100% (40 to 100%); specificity, 83% (52 to 98%); positive predictive value, 67% (22 to 96%); negative predictive value, 100% (69 to 100%); positive likelihood ratio, 6.0 (1.58 to 19.4); and negative likelihood ratio, 0 (0 to 0.6). Results indicate good inter-tester reliability and suggest that the slump knee bend test has potential to be a useful clinical test for identifying patients with mid lumbar nerve root compression. Further investigation is needed on larger numbers of patients to confirm these findings. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Ultra-high resolution computed tomography imaging
Paulus, Michael J.; Sari-Sarraf, Hamed; Tobin, Jr., Kenneth William; Gleason, Shaun S.; Thomas, Jr., Clarence E.
2002-01-01
A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.
Di Silvestre, Mario; Lolli, Francesco; Bakaloudis, Georgios; Maredi, Elena; Vommaro, Francesco; Pastorelli, Francesca
2013-02-01
Direct apical vertebral rotation represents an important goal of posterior surgery for thoracic adolescent idiopathic scoliosis (AIS), so as to obtain a better cosmetic effect and to avoid posterior thoracoplasty. However, the real effectiveness in correction of vertebral rotation, using posterior only procedures, is still open to debate. The aim of the present study is to compare the correction of axial apical rotation obtained with direct rotation procedure versus simple concave rod rotation, in patients treated by posterior fusion for thoracic AIS using pedicle screw-only construct. A retrospective review was performed on a total of 62 consecutive patients (one single institution, three different surgeons) affected by AIS, who had undergone a posterior spinal fusion with pedicle screw-only instrumentation between January 2005 and April 2008 at the reference center. All cases presented a main thoracic curve (Lenke type 1 and 2). The angle of rotation (RAsag) of the apical vertebra was measured from the preoperative and last follow-up axial CT. According to the derotation procedure, two groups were identified: a direct vertebral rotation group (DR group; n = 32 patients) and a simple concave rod rotation group (No-DR group; n = 30 patients). There were no statistical differences between the two groups, in terms of age, Risser's sign, curve patterns, Cobb main thoracic (MT) curve magnitude and flexibility, extension of fusion, offset measurements on the coronal plane and sagittal preoperative contour. All 62 patients were reviewed at an average follow-up of 3.7 years (range 2.5-4.2 years). The DR group compared to the No-DR group showed a significantly better final correction of apical vertebral rotation (DR 63.4 % vs. No-DR 14.8 %; p < 0.05) and a greater final correction (61.3 vs. 52.4 %; p < 0.05) with better maintenance of the initial correction (-1.7° vs. -1.9°; ns) of the main thoracic curve. Concerning the coronal balance, there was the same aforementioned trend of better results in the DR group, with less final apical MT vertebra translation (DR 2.2 cm vs. No-DR 4.1 cm), greater overall change (preop-final) of lower instrumented vertebra (LIV) coronal tilt (-14.9° vs. -11.1°; p < 0.05); the final global coronal balance (C7-S1) resulted quite better in DR group, but without a significant difference. The T5-T12 kyphosis angle was quite similar in both group before surgery (DR 16.8° vs. No-DR 17.5°) and was little lower at final follow-up evaluation in direct vertebral rotation group (14.5° vs. 16.5°). The T10-L2 sagittal alignment angle was similar in each group before surgery (12.5° in DR vs. 11.8° in No-DR), and at the latest follow-up averaged 5.3° versus 8.2°, respectively. Lumbar lordosis was similar in each group before surgery (DR -42° vs. No-DR -44.1°) and at the final follow-up evaluation (-45.9° vs. -43.2°). At the latest follow-up, SRS-30 and SF-36 findings were similar between the two groups. The complication rate was higher in the simple concave rod rotation group (13.3 vs. 9.3 %), related in two cases to thoracoplasty, which was never utilized in direct rotation patients. The direct vertebral rotation obtained significantly better final results, when compared to simple concave rod rotation, both concerning correction of apical vertebral rotation and magnitude of MT curve. On the other hand, the DR group presented a little reduction in T5-T12 kyphosis at follow-up, in comparison with concave rod rotation procedure. Both procedures were found to be satisfying from patients' perspective. Nevertheless overall complication rate was higher in the simple concave rod rotation group, related mainly to thoracoplasty (2 cases), which was never necessary in direct rotation patients.
Estimate of higher order ionospheric errors in GNSS positioning
NASA Astrophysics Data System (ADS)
Hoque, M. Mainul; Jakowski, N.
2008-10-01
Precise navigation and positioning using GPS/GLONASS/Galileo require the ionospheric propagation errors to be accurately determined and corrected for. Current dual-frequency method of ionospheric correction ignores higher order ionospheric errors such as the second and third order ionospheric terms in the refractive index formula and errors due to bending of the signal. The total electron content (TEC) is assumed to be same at two GPS frequencies. All these assumptions lead to erroneous estimations and corrections of the ionospheric errors. In this paper a rigorous treatment of these problems is presented. Different approximation formulas have been proposed to correct errors due to excess path length in addition to the free space path length, TEC difference at two GNSS frequencies, and third-order ionospheric term. The GPS dual-frequency residual range errors can be corrected within millimeter level accuracy using the proposed correction formulas.
Joint excitation synchronization characteristics of fatigue test for offshore wind turbine blade
NASA Astrophysics Data System (ADS)
Zhang, Lei-an; Yu, Xiang-yong; Wei, Xiu-ting; Liu, Wei-sheng
2018-02-01
In the case of the stiffness of offshore wind turbine blade is relatively large, the joint excitation device solves the problem of low accuracy of bending moment distribution, insufficient driving ability and long fatigue test period in single-point loading. In order to study the synchronous characteristics of joint excitation system, avoid blade vibration disturbance. First, on the base of a Lagrange equation, a mathematical model of combined excitation is formulated, and a numerical analysis of vibration synchronization is performed. Then, the model is constructed via MATLAB/Simulink, and the effect of the phase difference on the vibration synchronization characteristics is obtained visually. Finally, a set of joint excitation platform for the fatigue test of offshore wind turbine blades are built. The parameter measurement scheme is given and the correctness of the joint excitation synchronization in the simulation model is verified. The results show that when the rotational speed difference is 2 r/min, 30 r/min, the phase difference is 0, π/20, π/8 and π/4, as the rotational speed difference and the phase difference increase, the time required for the blade to reach a steady state is longer. When the phase difference is too large, the electromechanical coupling can no longer make the joint excitation device appear self-synchronizing phenomenon, so that the value of the phase difference develops toward a fixed value (not equal to 0), and the blade vibration disorder is serious, at this time, the effect of electromechanical coupling must be eliminated. The research results provide theoretical basis for the subsequent decoupling control algorithm and synchronization control strategy, and have good application value.
Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin
2017-07-28
Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.
Vibration-Rotation Spectrum of Formic Acid Dimer in the 7.3μm Region
NASA Astrophysics Data System (ADS)
Duan, Chuanxi
2016-06-01
The vibration-rotation-tunneling spectrum of formic acid dimer, (HCOOH)2, in the spectral region 1369-1375 wn has been measured by a multi-step rapid-can method in a slit jet expansion using a distributed-feedback quantum cascade laser. The observed spectrum is assigned to the O-C-H bending fundamental band. The tunneling splitting in the vibrational excited state is determined to be about 0.005 wn, which is much smaller than that in the ground state, 0.0165 wn (Goroya et al.,J. Chem. Phys. 140, 164311 (2014)). Strong local perturbations involving transitions with J > 9, K = 0 and 1 are identified in the observed spectrum. The deperturbation analysis will be presented.
NASA Astrophysics Data System (ADS)
Rezzolla, L.; Ahmedov, B. J.; Miller, J. C.
2001-04-01
We present analytic solutions of Maxwell equations in the internal and external background space-time of a slowly rotating magnetized neutron star. The star is considered isolated and in vacuum, with a dipolar magnetic field not aligned with the axis of rotation. With respect to a flat space-time solution, general relativity introduces corrections related both to the monopolar and the dipolar parts of the gravitational field. In particular, we show that in the case of infinite electrical conductivity general relativistic corrections resulting from the dragging of reference frames are present, but only in the expression for the electric field. In the case of finite electrical conductivity, however, corrections resulting from both the space-time curvature and the dragging of reference frames are shown to be present in the induction equation. These corrections could be relevant for the evolution of the magnetic fields of pulsars and magnetars. The solutions found, while obtained through some simplifying assumption, reflect a rather general physical configuration and could therefore be used in a variety of astrophysical situations.
Lei, Yu; Wu, Qiuwen
2010-04-21
Offline adaptive radiotherapy (ART) has been used to effectively correct and compensate for prostate motion and reduce the required margin. The efficacy depends on the characteristics of the patient setup error and interfraction motion through the whole treatment; specifically, systematic errors are corrected and random errors are compensated for through the margins. In online image-guided radiation therapy (IGRT) of prostate cancer, the translational setup error and inter-fractional prostate motion are corrected through pre-treatment imaging and couch correction at each fraction. However, the rotation and deformation of the target are not corrected and only accounted for with margins in treatment planning. The purpose of this study was to investigate whether the offline ART strategy is necessary for an online IGRT protocol and to evaluate the benefit of the hybrid strategy. First, to investigate the rationale of the hybrid strategy, 592 cone-beam-computed tomography (CBCT) images taken before and after each fraction for an online IGRT protocol from 16 patients were analyzed. Specifically, the characteristics of prostate rotation were analyzed. It was found that there exist systematic inter-fractional prostate rotations, and they are patient specific. These rotations, if not corrected, are persistent through the treatment fraction, and rotations detected in early fractions are representative of those in later fractions. These findings suggest that the offline adaptive replanning strategy is beneficial to the online IGRT protocol with further margin reductions. Second, to quantitatively evaluate the benefit of the hybrid strategy, 412 repeated helical CT scans from 25 patients during the course of treatment were included in the replanning study. Both low-risk patients (LRP, clinical target volume, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles) were included in the simulation. The contours of prostate and seminal vesicles were delineated on each CT. The benefit of margin reduction to compensate for both rotation and deformation in the hybrid strategy was evaluated geometrically. With the hybrid strategy, the planning margins can be reduced by 1.4 mm for LRP, and 2.0 mm for IRP, compared with the standard online IGRT only, to maintain the same 99% target volume coverage. The average relative reduction in planning target volume (PTV) based on the internal target volume (ITV) from PTV based on CTV is 19% for LRP, and 27% for IRP.
NASA Astrophysics Data System (ADS)
Wei, Yingsan; Wang, Yongsheng
2013-04-01
This study presents the unsteady hydrodynamics of the excitations from a 5-bladed propeller at two rotating speeds running in the wake of a small-scaled submarine and the behavior of the submarine's structure and acoustic responses under the propeller excitations. Firstly, the propeller flow and submarine flows are independently validated. The propulsion of the hull-propeller is simulated using computational fluid dynamics (CFD), so as to obtain the transient responses of the propeller excitations. Finally, the structure and acoustic responses of the submarine under propeller excitations are predicted using a finite element/boundary element model in the frequency domain. Results show that (1) the propeller excitations are tonal at the propeller harmonics, and the propeller transversal force is bigger than vertical force. (2) The structure and acoustic responses of the submarine hull is tonal mainly at the propeller harmonics and the resonant mode frequencies of the hull, and the breathing mode in axial direction as well as the bending modes in vertical and transversal directions of the hull can generate strong structure vibration and underwater noise. (3) The maximum sound pressure of the field points increases with the increasing propeller rotating speed at structure resonances and propeller harmonics, and the rudders resonant mode also contributes a lot to the sound radiation. Lastly, the critical rotating speeds of the submarine propeller are determined, which should be carefully taken into consideration when match the propeller with prime mover in the propulsion system. This work shows the importance of the propeller's tonal excitation and the breathing mode plus the bending modes in evaluating submarine's noise radiation.
Hypothetical model for the bending of the Mariana Arc
NASA Astrophysics Data System (ADS)
McCabe, Robert; Uyeda, Seiya
The southern Mariana Arc has a distinct eastward convex shape which is more pronounced than the typical arcuate structure observed above oceanic subduction zones. The Yap Trench is offset hundreds of kilometers westward from the main Izu-Bonin-Mariana trend. Between the southern Mariana Arc and the Yap Trench, the Mariana Arc has an anomalous east-west orientation and is characterized by a markedly lower seismicity than the main Mariana trend. Situated east of the Yap Trench is the ESE trending Caroline Ridge that geochemically resembles the Hawaiian hot spot trend. Paleomagnetic data from Truk and the generally increasing ages to the WNW trend of the Caroline Ridge suggest that the Caroline Ridge is part of the Pacific plate as suggested by Clague and Jarrard (1973). Pacific plate motion for the Caroline Ridge predicts that the ridge has collided with the Yap Trench during the Tertiary. Other evidence for this collision is observed on the island of Yap and by the fact that this portion of the arc has not had volcanic activity during the Neogene period. Paleomagnetic studies show that since the early Oligocene, Guam has rotated greater than 50° clockwise. During this same period, Saipan has rotated only 35° clockwise. These data, the similar bends of the west Mariana Ridge and the Mariana Ridge, and the orientation of fold axes on Guam and Saipan suggest that the clockwise rotation occurred after the initiation of spreading of the Parece Vela Basin and before the opening of the Mariana Trough. This investigation also suggests that the east-west trending portion of the Mariana Trench is a transform boundary which developed in response to the collision.
The influence of golf shaft stiffness on grip and clubhead kinematics.
MacKenzie, Sasho J; Boucher, Daniel E
2017-01-01
The purpose of this study was to investigate the influence of shaft stiffness on grip and clubhead kinematics. Two driver shafts with disparate levels of stiffness, but very similar inertial properties, were tested by 33 golfers representing a range of abilities. Shaft deflection data as well as grip and clubhead kinematics were collected from 14 swings, with each shaft, for each golfer using an optical motion capture system. The more flexible shaft (R-Flex) demonstrated a higher contribution to clubhead speed from shaft deflection dynamics (P < .001), but was also associated with significantly less grip angular velocity at impact (P = .001), resulting in no significant difference in clubhead speed (P = .14). However, at the individual level, half of the participants demonstrated a significant difference in clubhead speed between shafts. The more flexible shaft was also associated with significantly different magnitudes of head rotation relative to the grip. More specifically, both bend loft (P < .001) and bend lie (P < .001) were greater for the R-Flex shaft, while bend close (P = .017) was greater for the stiffer (X-Flex) shaft. However, changes in grip orientation resulted in no significant differences in face orientation, between the shafts, at impact.
Comparison of upwind and downwind rotor operation of the DOE/NASA 100-kW MOD-0 wind turbine
NASA Technical Reports Server (NTRS)
Glasgow, J. C.; Miller, D. R.; Corrigan, R. D.
1981-01-01
Tests were conducted on a 38m diameter horizontal axis wind turbine, which had first a rotor downwind of the supporting truss tower and then upwind of the tower. Aside from the placement of the rotor and the direction of rotation of the drive train, the wind turbine was identical for both tests. Three aspects of the test results are compared: rotor blade bending loads, rotor teeter response, and nacelle yaw moments. As a result of the tests, it is shown that while mean flatwise bending moments were unaffected by the placement of the rotor, cyclic flatwise bending tended to increase with wind speed for the downwind rotor while remaining somewhat uniform with wind speed for the upwind rotor, reflecting the effects of increased flow disturbance for downwind rotor. Rotor teeter response was not significantly affected by the rotor location relative to the tower, but appears to reflect reduced teeter stability near rated wind speed for both configurations. Teeter stability appears to return above rated wind speed, however. Nacelle yaw moments are higher for the upwind rotor but do not indicate significant design problems for either configuration.
Molecular Mechanics of the α-Actinin Rod Domain: Bending, Torsional, and Extensional Behavior
Golji, Javad; Collins, Robert; Mofrad, Mohammad R. K.
2009-01-01
α-Actinin is an actin crosslinking molecule that can serve as a scaffold and maintain dynamic actin filament networks. As a crosslinker in the stressed cytoskeleton, α-actinin can retain conformation, function, and strength. α-Actinin has an actin binding domain and a calmodulin homology domain separated by a long rod domain. Using molecular dynamics and normal mode analysis, we suggest that the α-actinin rod domain has flexible terminal regions which can twist and extend under mechanical stress, yet has a highly rigid interior region stabilized by aromatic packing within each spectrin repeat, by electrostatic interactions between the spectrin repeats, and by strong salt bridges between its two anti-parallel monomers. By exploring the natural vibrations of the α-actinin rod domain and by conducting bending molecular dynamics simulations we also predict that bending of the rod domain is possible with minimal force. We introduce computational methods for analyzing the torsional strain of molecules using rotating constraints. Molecular dynamics extension of the α-actinin rod is also performed, demonstrating transduction of the unfolding forces across salt bridges to the associated monomer of the α-actinin rod domain. PMID:19436721
NASA Astrophysics Data System (ADS)
Han, Huixian; Li, Anyang; Guo, Hua
2014-12-01
A new full-dimensional global potential energy surface (PES) for the acetylene-vinylidene isomerization on the ground (S0) electronic state has been constructed by fitting ˜37 000 high-level ab initio points using the permutation invariant polynomial-neural network method with a root mean square error of 9.54 cm-1. The geometries and harmonic vibrational frequencies of acetylene, vinylidene, and all other stationary points (two distinct transition states and one secondary minimum in between) have been determined on this PES. Furthermore, acetylene vibrational energy levels have been calculated using the Lanczos algorithm with an exact (J = 0) Hamiltonian. The vibrational energies up to 12 700 cm-1 above the zero-point energy are in excellent agreement with the experimentally derived effective Hamiltonians, suggesting that the PES is approaching spectroscopic accuracy. In addition, analyses of the wavefunctions confirm the experimentally observed emergence of the local bending and counter-rotational modes in the highly excited bending vibrational states. The reproduction of the experimentally derived effective Hamiltonians for highly excited bending states signals the coming of age for the ab initio based PES, which can now be trusted for studying the isomerization reaction.
High-power picosecond pulse delivery through hollow core photonic band gap fibers
NASA Astrophysics Data System (ADS)
Michieletto, Mattia; Johansen, Mette M.; Lyngsø, Jens K.; Lægsgaard, Jesper; Bang, Ole; Alkeskjold, Thomas T.
2016-03-01
We demonstrated robust and bend insensitive fiber delivery of high power laser with diffraction limited beam quality for two different kinds of hollow core band gap fibers. The light source for this experiment consists of ytterbium-doped double clad fiber aeroGAIN-ROD-PM85 in a high power amplifier setup. It provided 22ps pulses with a maximum average power of 95W, 40MHz repetition rate at 1032nm (~2.4μJ pulse energy), with M2 <1.3. We determined the facet damage threshold for a 7-cells hollow core photonic bandgap fiber and showed up to 59W average power output for a 5 meters fiber. The damage threshold for a 19-cell hollow core photonic bandgap fiber exceeded the maximum power provided by the light source and up to 76W average output power was demonstrated for a 1m fiber. In both cases, no special attention was needed to mitigate bend sensitivity. The fibers were coiled on 8 centimeters radius spools and even lower bending radii were present. In addition, stimulated rotational Raman scattering arising from nitrogen molecules was measured through a 42m long 19 cell hollow core fiber.
NASA Astrophysics Data System (ADS)
Chertok, I. M.; Belov, A. V.
2018-03-01
Correction to: Solar Phys https://doi.org/10.1007/s11207-017-1169-1 We found an important error in the text of our article. On page 6, the second sentence of Section 3.2 "We studied the variations in soft X-ray flare characteristics in more detail by averaging them within the running windows of ± one Carrington rotation with a step of two rotations." should instead read "We studied the variations in soft X-ray flare characteristics in more detail by averaging them within the running windows of ± 2.5 Carrington rotations with a step of two rotations." We regret the inconvenience. The online version of the original article can be found at https://doi.org/10.1007/s11207-017-1169-1
Rhenium Alloys as Ductile Substrates for Diamond Thin-Film Electrodes.
Halpern, Jeffrey M; Martin, Heidi B
2014-02-01
Molybdenum-rhenium (Mo/Re) and tungsten-rhenium (W/Re) alloys were investigated as substrates for thin-film, polycrystalline boron-doped diamond electrodes. Traditional, carbide-forming metal substrates adhere strongly to diamond but lose their ductility during exposure to the high-temperature (1000°C) diamond, chemical vapor deposition environment. Boron-doped semi-metallic diamond was selectively deposited for up to 20 hours on one end of Mo/Re (47.5/52.5 wt.%) and W/Re (75/25 wt.%) alloy wires. Conformal diamond films on the alloys displayed grain sizes and Raman signatures similar to films grown on tungsten; in all cases, the morphology and Raman spectra were consistent with well-faceted, microcrystalline diamond with minimal sp 2 carbon content. Cyclic voltammograms of dopamine in phosphate-buffered saline (PBS) showed the wide window and low baseline current of high-quality diamond electrodes. In addition, the films showed consistently well-defined, dopamine electrochemical redox activity. The Mo/Re substrate regions that were uncoated but still exposed to the diamond-growth environment remained substantially more flexible than tungsten in a bend-to-fracture rotation test, bending to the test maximum of 90° and not fracturing. The W/Re substrates fractured after a 27° bend, and the tungsten fractured after a 21° bend. Brittle, transgranular cleavage fracture surfaces were observed for tungsten and W/Re. A tension-induced fracture of the Mo/Re after the prior bend test showed a dimple fracture with a visible ductile core. Overall, the Mo/Re and W/Re alloys were suitable substrates for diamond growth. The Mo/Re alloy remained significantly more ductile than traditional tungsten substrates after diamond growth, and thus may be an attractive metal substrate for more ductile, thin-film diamond electrodes.
Rhenium Alloys as Ductile Substrates for Diamond Thin-Film Electrodes
Halpern, Jeffrey M.; Martin, Heidi B.
2014-01-01
Molybdenum-rhenium (Mo/Re) and tungsten-rhenium (W/Re) alloys were investigated as substrates for thin-film, polycrystalline boron-doped diamond electrodes. Traditional, carbide-forming metal substrates adhere strongly to diamond but lose their ductility during exposure to the high-temperature (1000°C) diamond, chemical vapor deposition environment. Boron-doped semi-metallic diamond was selectively deposited for up to 20 hours on one end of Mo/Re (47.5/52.5 wt.%) and W/Re (75/25 wt.%) alloy wires. Conformal diamond films on the alloys displayed grain sizes and Raman signatures similar to films grown on tungsten; in all cases, the morphology and Raman spectra were consistent with well-faceted, microcrystalline diamond with minimal sp2 carbon content. Cyclic voltammograms of dopamine in phosphate-buffered saline (PBS) showed the wide window and low baseline current of high-quality diamond electrodes. In addition, the films showed consistently well-defined, dopamine electrochemical redox activity. The Mo/Re substrate regions that were uncoated but still exposed to the diamond-growth environment remained substantially more flexible than tungsten in a bend-to-fracture rotation test, bending to the test maximum of 90° and not fracturing. The W/Re substrates fractured after a 27° bend, and the tungsten fractured after a 21° bend. Brittle, transgranular cleavage fracture surfaces were observed for tungsten and W/Re. A tension-induced fracture of the Mo/Re after the prior bend test showed a dimple fracture with a visible ductile core. Overall, the Mo/Re and W/Re alloys were suitable substrates for diamond growth. The Mo/Re alloy remained significantly more ductile than traditional tungsten substrates after diamond growth, and thus may be an attractive metal substrate for more ductile, thin-film diamond electrodes. PMID:25404788
NASA Astrophysics Data System (ADS)
Cesar, Roberto Marcondes; Costa, Luciano da Fontoura
1997-05-01
The estimation of the curvature of experimentally obtained curves is an important issue in many applications of image analysis including biophysics, biology, particle physics, and high energy physics. However, the accurate calculation of the curvature of digital contours has proven to be a difficult endeavor, mainly because of the noise and distortions that are always present in sampled signals. Errors ranging from 1% to 1000% have been reported with respect to the application of standard techniques in the estimation of the curvature of circular contours [M. Worring and A. W. M. Smeulders, CVGIP: Im. Understanding, 58, 366 (1993)]. This article explains how diagrams of multiscale bending energy can be easily obtained from curvegrams and used as a robust general feature for morphometric characterization of neural cells. The bending energy is an interesting global feature for shape characterization that expresses the amount of energy needed to transform the specific shape under analysis into its lowest energy state (i.e., a circle). The curvegram, which can be accurately obtained by using digital signal processing techniques (more specifically through the Fourier transform and its inverse, as described in this work), provides multiscale representation of the curvature of digital contours. The estimation of the bending energy from the curvegram is introduced and exemplified with respect to a series of neural cells. The masked high curvature effect is reported and its implications to shape analysis are discussed. It is also discussed and illustrated that, by normalizing the multiscale bending energy with respect to a standard circle of unitary perimeter, this feature becomes an effective means for expressing shape complexity in a way that is invariant to rotation, translation, and scaling, and that is robust to noise and other artifacts implied by image acquisition.
Experimental Attempts for Deep Insertion in Ultrasonically Forced Insertion Process
NASA Astrophysics Data System (ADS)
Ono, Satoshi; Aoyagi, Manabu; Tamura, Hideki; Takano, Takehiro
2011-07-01
In this paper, we describe two attempts of obtaining deep insertion in an ultrasonically forced insertion (USFI) process. One was to correct the inclination of an inserted rod by passively generated bending vibrations. The inclination causes a partial plastic deformation, which decreases the holding power of processing materials. Two types of horn with grooves for excitation of bending vibrations were examined. The other was to make differences in vibration velocity and the phase of a rod and a metal plate by damping the vibration of a metal plate by using a rubber sheet. As results, the attempts proposed in this study were confirmed to be effective to obtain a deep insertion.
On a third-order shear deformation theory for laminated composite shells
NASA Technical Reports Server (NTRS)
Liu, C. F.; Reddy, J. N.
1986-01-01
A higher-order theory based on an assumed displacement field in which the surface displacements are expanded in powers of the thickness coordinate up to the third order is presented. The theory allows parabolic description of the transverse shear stresses, and therefore the shear correction factors of the usual shear deformation theory are not required in the present theory. The theory also accounts for small strains but moderately large displacements (i.e., von Karman strains). A finite-element model based on independent approximations of the displacements and bending moments (i.e., mixed formulation) is developed. The element is used to analyze cross-ply and angle-ply laminated shells for bending.
Saotome, Kousaku; Matsushita, Akira; Matsumoto, Koji; Kato, Yoshiaki; Nakai, Kei; Murata, Koichi; Yamamoto, Tetsuya; Sankai, Yoshiyuki; Matsumura, Akira
2017-02-01
A fast spin-echo sequence based on the Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) technique is a magnetic resonance (MR) imaging data acquisition and reconstruction method for correcting motion during scans. Previous studies attempted to verify the in vivo capabilities of motion-corrected PROPELLER in real clinical situations. However, such experiments are limited by repeated, stray head motion by research participants during the prescribed and precise head motion protocol of a PROPELLER acquisition. Therefore, our purpose was to develop a brain phantom set for motion-corrected PROPELLER. The profile curves of the signal intensities on the in vivo T 2 -weighted image (T 2 WI) and 3-D rapid prototyping technology were used to produce the phantom. In addition, we used a homemade driver system to achieve in-plane motion at the intended timing. We calculated the Pearson's correlation coefficient (R 2 ) between the signal intensities of the in vivo T 2 WI and the phantom T 2 WI and clarified the rotation precision of the driver system. In addition, we used the phantom set to perform initial experiments to show the rotational angle and frequency dependences of PROPELLER. The in vivo and phantom T 2 WIs were visually congruent, with a significant correlation (R 2 ) of 0.955 (p<.001). The rotational precision of the driver system was within 1 degree of tolerance. The experiment on the rotational angle dependency showed image discrepancies between the rotational angles. The experiment on the rotational frequency dependency showed that the reconstructed images became increasingly blurred by the corruption of the blades as the number of motions increased. In this study, we developed a phantom that showed image contrasts and construction similar to the in vivo T 2 WI. In addition, our homemade driver system achieved precise in-plane motion at the intended timing. Our proposed phantom set could perform systematic experiments with a real clinical MR image, which to date has not been possible in in vivo studies. Further investigation should focus on the improvement of the motion-correction algorithm in PROPELLER using our phantom set for what would traditionally be considered problematic patients (children, emergency patients, elderly, those with dementia, and so on). Copyright © 2016 Elsevier Inc. All rights reserved.
Shabbott, Britne A; Sainburg, Robert L
2010-05-01
Visuomotor adaptation is mediated by errors between intended and sensory-detected arm positions. However, it is not clear whether visual-based errors that are shown during the course of motion lead to qualitatively different or more efficient adaptation than errors shown after movement. For instance, continuous visual feedback mediates online error corrections, which may facilitate or inhibit the adaptation process. We addressed this question by manipulating the timing of visual error information and task instructions during a visuomotor adaptation task. Subjects were exposed to a visuomotor rotation, during which they received continuous visual feedback (CF) of hand position with instructions to correct or not correct online errors, or knowledge-of-results (KR), provided as a static hand-path at the end of each trial. Our results showed that all groups improved performance with practice, and that online error corrections were inconsequential to the adaptation process. However, in contrast to the CF groups, the KR group showed relatively small reductions in mean error with practice, increased inter-trial variability during rotation exposure, and more limited generalization across target distances and workspace. Further, although the KR group showed improved performance with practice, after-effects were minimal when the rotation was removed. These findings suggest that simultaneous visual and proprioceptive information is critical in altering neural representations of visuomotor maps, although delayed error information may elicit compensatory strategies to offset perturbations.
A new approach to correct yaw misalignment in the spinning ultrasonic anemometer
NASA Astrophysics Data System (ADS)
Ghaemi-Nasab, M.; Davari, Ali R.; Franchini, S.
2018-01-01
Single-axis ultrasonic anemometers are the modern instruments for accurate wind speed measurements. Despite their widespread and ever increasing applications, little attention has been paid up to now to spinning ultrasonic anemometers that can accurately measure both the wind speed and its direction in a single and robust apparatus. In this study, intensive wind-tunnel tests were conducted on a spinning single-axis ultrasonic anemometer to investigate the yaw misalignment in ultrasonic wind speed measurements during the yaw rotation. The anemometer was rotating inside the test section with various angular velocities, and the experiments were performed at several combinations of wind speed and anemometer angular velocity. The instantaneous angular position of the ultrasonic signal path with wind direction was measured using an angular position sensor. For a spinning anemometer, the circulatory wake and the associated flow distortion, along with the Doppler effect, impart a phase shift in the signals measured by the anemometer, which should be added to the position data for correcting the yaw misalignment. In this paper, the experimental data are used to construct a theoretical model, based on a response surface method, to correct the phase shift for various wind speeds and anemometer rotational velocities. This model is shown to successfully correct the velocity indicated by the spinning anemometer for the phase shift due to the rotation, and can easily be used in the calibration process for such anemometers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, X; Rosenfield, J; Dong, X
2016-06-15
Purpose: Rotational total skin electron irradiation (RTSEI) is used in the treatment of cutaneous T-cell lymphoma. Due to inter-film uniformity variations the dosimetry measurement of a large electron beam of a very low energy is challenging. This work provides a method to improve the accuracy of flatness and symmetry for a very large treatment field of low electron energy used in dual beam RTSEI. Methods: RTSEI is delivered by dual angles field a gantry of ±20 degrees of 270 to cover the upper and the lower halves of the patient body with acceptable beam uniformity. The field size is inmore » the order of 230cm in vertical height and 120 cm in horizontal width and beam energy is a degraded 6 MeV (6 mm of PMMA spoiler). We utilized parallel plate chambers, Gafchromic films and OSLDs as a measuring devices for absolute dose, B-Factor, stationary and rotational percent depth dose and beam uniformity. To reduce inter-film dosimetric variation we introduced a new specific correction method to analyze beam uniformity. This correction method uses some image processing techniques combining film value before and after radiation dose to compensate the inter-variation dose response differences among films. Results: Stationary and rotational depth of dose demonstrated that the Rp is 2 cm for rotational and the maximum dose is shifted toward the surface (3mm). The dosimetry for the phantom showed that dose uniformity reduced to 3.01% for the vertical flatness and 2.35% for horizontal flatness after correction thus achieving better flatness and uniformity. The absolute dose readings of calibrated films after our correction matched with the readings from OSLD. Conclusion: The proposed correction method for Gafchromic films will be a useful tool to correct inter-film dosimetric variation for the future clinical film dosimetry verification in very large fields, allowing the optimizations of other parameters.« less
Sun, X; Xu, L; Chen, Z H; Chen, X; Du, C Z; Li, S; Liu, Z; Qian, B P; Wang, B; Zhu, Z Z; Qiu, Y
2018-03-01
Objective: To evaluate the correction result of traditional dual growing rods on apical vertebral rotation. Methods: This study recruited 19 early-onset scoliosis patients (6 boys and 13 girls) who had received traditional dual growing rods treatment at Department of Spine Surgery, Nanjing Drum Tower Hospital from January 2009 to July 2015. The age at initial surgery was (5.7±1.7)years(range, 3 to 9 years). Measurements of primary curve magnitude, height of T(1)-S(1), apical vertebral translation(AVR), apical vertebral body-rib ratio, apical vertebral rotation, thoracic rotation and rib hump were compared between pre-operatively, post-operatively, and at latest follow-up, through a paired- t test. Pearson correlation test was used for correlation analysis between parameters. Results: All patients had a follow-up of (49.5±12.8)months(range, 24 to 71 months). A total of 111 operative procedures were performed, among which there were 92 lengthening procedures, averagely 4.8 lengthening procedures per patient. The average interval for each lengthening procedure was 10 months. The Cobb angle of primary curve was notably decreased from (66.5±13.2)° to (35.2±10.9)°( t =24.013, P <0.01), and no significant correction loss was found at the latest follow-up ((36.7±10.7)°)( t =-1.324, P =0.202). In addition, significant correction of AVR, thoracic rotation, apical vertebral translation, apical vertebra body-rib ratio, and rib hump were noted after initial surgery. Whereas, these parameters significant increased during follow-up(all P <0.05) except for thoracic rotation. Pearson correlation analysis showed that the increase of AVR during follow-up significantly correlated with change of apical vertebra translation, apical vertebral body-rib ratio, and rib hump( r =0.652, 0.814, 0.695; all P <0.05). Conclusions: Significant correction of AVR can be achieved after initial surgery in early-onset scoliosis patients treated with traditional dual growing rods. However, such a technique can hardly prevent the deterioration of AVR during follow-up.
NASA Astrophysics Data System (ADS)
Panasenko, N. N.; Sinelschikov, A. V.
2017-11-01
One of the main stages in the analysis of complex 3D structures and engineering constructions made of thin-walled open bars using FEM is a stiffness matrix developing. Taking into account middle surface shear deformation caused by the work of tangential stresses in the formula to calculate a potential energy of thin-walled open bars, the authors obtain an important correction at calculation of the bar deformation and fundamental frequencies. The results of the analysis of the free end buckling of a cantilever H-bar under plane bending differ from exact solution by 0.53%. In the course of comparison of the obtained results with the cantilever bar buckling regardless the middle surface shear deformation, an increase made 16.6%. The stiffness matrix of a thin-walled open bar developed in the present work can be integrated into any software suite using FEM for the analysis of complex 3-D structures and engineering constructions with n-freedoms.
Apparatus for controlling air/fuel ratio for internal combustion engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kato, K.; Mizuno, T.
1986-07-08
This patent describes an apparatus for controlling air-fuel ratio of an air-fuel mixture to be supplied to an internal combustion engine having an intake passage, an exhaust passage, an an exhaust gas recirculation passage for recirculating exhaust gases in the exhaust passage to the intake passage therethrough. The apparatus consists of: (a) means for sensing rotational speed of the engine; (b) means for sensing intake pressure in the intake passage; (c) means for sensing atmospheric pressure; (d) means for enabling and disabling exhaust gas recirculation through the exhaust gas recirculation passage in accordance with operating condition of the engine; (e)more » means for determining required amount of fuel in accordance with the sensed rotational speed and the sensed intake pressure; (f) means for determining, when the exhaust gas recirculation is enabled, a first correction value in accordance with the sensed rotational speed, the sensed intake pressure and the sensed atmospheric pressure, the first correction factor being used for correcting fuel amount so as to compensate for the decrease of fuel due to the performance of exhaust gas recirculation and also to compensate for the change in atmospheric pressure; (g) means for determining, when the exhaust gas recirculation is disabled, a second correction value in accordance with the atmospheric pressure, the second correction factor being used so as to compensate for the change in atmospheric pressure; (h) means for correcting the required amount of fuel by the first correction value and the second correction value when the exhaust gas recirculation is enabled and disabled respectively; and (i) means for supplying the engine with the corrected amount of fuel.« less
Dual-beam manually-actuated distortion-corrected imaging (DMDI) with micromotor catheters.
Lee, Anthony M D; Hohert, Geoffrey; Angkiriwang, Patricia T; MacAulay, Calum; Lane, Pierre
2017-09-04
We present a new paradigm for performing two-dimensional scanning called dual-beam manually-actuated distortion-corrected imaging (DMDI). DMDI operates by imaging the same object with two spatially-separated beams that are being mechanically scanned rapidly in one dimension with slower manual actuation along a second dimension. Registration of common features between the two imaging channels allows remapping of the images to correct for distortions due to manual actuation. We demonstrate DMDI using a 4.7 mm OD rotationally scanning dual-beam micromotor catheter (DBMC). The DBMC requires a simple, one-time calibration of the beam paths by imaging a patterned phantom. DMDI allows for distortion correction of non-uniform axial speed and rotational motion of the DBMC. We show the utility of this technique by demonstrating en face OCT image distortion correction of a manually-scanned checkerboard phantom and fingerprint scan.
Three-dimensional analysis of scoliosis surgery using stereophotogrammetry
NASA Astrophysics Data System (ADS)
Jang, Stanley B.; Booth, Kellogg S.; Reilly, Chris W.; Sawatzky, Bonita J.; Tredwell, Stephen J.
1994-04-01
A new stereophotogrammetric analysis and 3D visualization allow accurate assessment of the scoliotic spine during instrumentation. Stereophoto pairs taken at each stage of the operation and robust statistical techniques are used to compute 3D transformations of the vertebrae between stages. These determine rotation, translation, goodness of fit, and overall spinal contour. A polygonal model of the spine using commercial 3D modeling package is used to produce an animation sequence of the transformation. The visualization have provided some important observation. Correction of the scoliosis is achieved largely through vertebral translation and coronal plane rotation, contrary to claims that large axial rotations are required. The animations provide valuable qualitative information for surgeons assessing the results of scoliotic correction.
NASA Astrophysics Data System (ADS)
Heberer, Bianca; Neubauer, Franz
2017-04-01
Curvature is an intriguing feature within many mountain belts worldwide. Several proposals have been made for deciphering the origin of curvature, however, there is still significant debate about the bend-forming mechanisms, the consequences as well as on how bending is accommodated within the lithosphere. Only few of the worldwide oroclines have been studied in detail and a variety of alternative controlling factors, such as the role of inherited structures, the rheological coupling between lower and upper plates, the presence of a basement promontory in the foreland and its particular geometry, and lateral orogen-parallel extrusion are likely underestimated or not considered at all. This study focuses on oroclinal bending at the transition from the W-E trending Eastern Alps to the SW-NE oriented Western Carpathians. There, the orogenic front is concave towards the Alpine foreland and the greatest degree of curvature (ca. 55°) is found adjacent to the Bohemian massif. The oroclinal axis runs from the Bohemian promontory to the South Burgenland high. Various competing mechanisms occurred, i.e. rotation around a stiff foreland promontory and lateral extrusion induced by tectonic escape due to the indentation of a microplate and extensional collapse due to slab-rollback beneath the Carpathians. Little is known for such cases, where bending around as well as overriding of a promontory occurs, particularly on how it controls the exhumational and structural architecture within the orogen itself. Based on a synthesis of low-T thermochronology and structural data we find a significant impact of oroclinal bending on exhumation and structures: Highest amounts of erosion occur in the immediate vicinity of the Bohemian promontory and along its prolongation in the South Burgenland high, corroborating that shortening and exhumation are most pronounced there and should decrease along-strike of the orogenic front. In the outer bend strong Miocene extensional thinning parallel to the orogen occurred contemporaneously with sediment deposition to the east (Danube basin) and west (Styrian basin) of the oroclinal axis. We speculate that the location of extension at least from the Vienna and Danube basins are in part controlled by Jurassic extensional structures. The central sector along the oroclinal axis is largely overprinted by lateral block extrusion where the influence of oroclinal bending and a protruding promontory in the subsurface has yet to be demonstrated.
Fogel, Guy R; Parikh, Rachit D; Ryu, Stephen I; Turner, Alexander W L
2014-03-01
Lumbar interbody fusion is indicated in the treatment of degenerative conditions. Laterally inserted interbody cages significantly decrease range of motion (ROM) compared with other cages. Supplemental fixation options such as lateral plates or spinous process plates have been shown to provide stability and to reduce morbidity. The authors of the current study investigate the in vitro stability of the interbody cage with a combination of lateral and spinous process plate fixation and compare this method to the established bilateral pedicle screw fixation technique. Ten L1-5 specimens were evaluated using multidirectional nondestructive moments (± 7.5 N · m), with a custom 6 degrees-of-freedom spine simulator. Intervertebral motions (ROM) were measured optoelectronically. Each spine was evaluated under the following conditions at the L3-4 level: intact; interbody cage alone (stand-alone); cage supplemented with lateral plate; cage supplemented with ipsilateral pedicle screws; cage supplemented with bilateral pedicle screws; cage supplemented with spinous process plate; and cage supplemented with a combination of lateral plate and spinous process plate. Intervertebral rotations were calculated, and ROM data were normalized to the intact ROM data. The stand-alone laterally inserted interbody cage significantly reduced ROM with respect to the intact state in flexion-extension (31.6% intact ROM, p < 0.001), lateral bending (32.5%, p < 0.001), and axial rotation (69.4%, p = 0.002). Compared with the stand-alone condition, addition of a lateral plate to the interbody cage did not significantly alter the ROM in flexion-extension (p = 0.904); however, it was significantly decreased in lateral bending and axial rotation (p < 0.001). The cage supplemented with a lateral plate was not statistically different from bilateral pedicle screws in lateral bending (p = 0.579). Supplemental fixation using a spinous process plate was not significantly different from bilateral pedicle screws in flexion-extension (p = 0.476). The combination of lateral plate and spinous process plate was not statistically different from the cage supplemented with bilateral pedicle screws in all the loading modes (p ≥ 0.365). A combination of lateral and spinous process plate fixation to supplement a laterally inserted interbody cage helps achieve rigidity in all motion planes similar to that achieved with bilateral pedicle screws.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-04
... Emergencies,'' for repair and corrective actions states that two individuals, one Mechanical Maintenance... actions will be taken to ensure basic electrical/l&C tasks can be performed by Mechanical Maintenance personnel. Mechanical Maintenance personnel will receive training in basic electrical and I&C tasks to...
Aeroservoelastic Tailoring with Piezoelectric Materials: Actuator Optimization Studies
1994-02-09
publcreease AirFre usfied tof Scentrolstrctua defleactio ofarstcsstm.h robe iSP tofrish geometrica Arrangemien fo8c1ecnro;adotmm1oeaeo5uraepnl o control...of the plate. The differential bending induces warping in the - correct " direction of twisL 2.3 The elemental model The basic building block finite
New design studies for TRIUMF's ARIEL High Resolution Separator
NASA Astrophysics Data System (ADS)
Maloney, J. A.; Baartman, R.; Marchetto, M.
2016-06-01
As part of its new Advanced Rare IsotopE Laboratory (ARIEL), TRIUMF is designing a novel High Resolution Separator (HRS) (Maloney et al., 2015) to separate rare isotopes. The HRS has a 180° bend, separated into two 90° magnetic dipoles, bend radius 1.2 m, with an electrostatic multipole corrector between them. Second order correction comes mainly from the dipole edge curvatures, but is intended to be fine-tuned with a sextupole component and a small octupole component in the multipole. This combination is designed to achieve 1:20,000 resolution for a 3 μm (horizontal) and 6 μm (vertical) emittance. A design for the HRS dipole magnets achieves both radial and integral flatness goals of <10-5. A review of the optical design for the HRS is presented, including the study of limiting factors affecting separation, matching and aberration correction. Field simulations from the OPERA-3D (OPERA) [2] models of the dipole magnets are used in COSY Infinity (COSY) (Berz and Makino, 2005) [3] to find and optimize the transfer maps to 3rd order and study residual nonlinearities to 8th order.
Turbulent flow in a 180 deg bend: Modeling and computations
NASA Technical Reports Server (NTRS)
Kaul, Upender K.
1989-01-01
A low Reynolds number k-epsilon turbulence model was presented which yields accurate predictions of the kinetic energy near the wall. The model is validated with the experimental channel flow data of Kreplin and Eckelmann. The predictions are also compared with earlier results from direct simulation of turbulent channel flow. The model is especially useful for internal flows where the inflow boundary condition of epsilon is not easily prescribed. The model partly derives from some observations based on earlier direct simulation results of near-wall turbulence. The low Reynolds number turbulence model together with an existing curvature correction appropriate to spinning cylinder flows was used to simulate the flow in a U-bend with the same radius of curvature as the Space Shuttle Main Engine (SSME) Turn-Around Duct (TAD). The present computations indicate a space varying curvature correction parameter as opposed to a constant parameter as used in the spinning cylinder flows. Comparison with limited available experimental data is made. The comparison is favorable, but detailed experimental data is needed to further improve the curvature model.
Parsimonious evaluation of concentric-tube continuum robot equilibrium conformation.
Rucker, Daniel Caleb; Webster Iii, Robert J
2009-09-01
Dexterous at small diameters, continuum robots consisting of precurved concentric tubes are well-suited for minimally invasive surgery. These active cannulas are actuated by relative translations and rotations applied at the tube bases, which create bending via elastic tube interaction. An accurate kinematic model of cannula shape is required for applications in surgical and other settings. Previous models are limited to circular tube precurvatures, and neglect torsional deformation in curved sections. Recent generalizations account for arbitrary tube preshaping and bending and torsion throughout the cannula, providing differential equations that define cannula shape. In this paper, we show how to simplify these equations using Frenet-Serret frames. An advantage of this approach is the interpretation of torsional components of the preset tube shapes as "forcing functions" on the cannula's differential equations. We also elucidate a process for numerically solving the differential equations, and use it to produce simulations illustrating the implications of torsional deformation and helical tube shapes.
The dynamic instability in the hook/flagellum system that triggers bacterial flicks
NASA Astrophysics Data System (ADS)
Jabbarzadeh, Mehdi; Fu, Henry
2017-11-01
Dynamical bending, buckling, and polymorphic transformations of the flagellum are known to affect bacterial motility, but run-reverse-flick motility of monotrichous bacteria also involves the even more flexible hook, which connects the flagellum to the cell body. Here, we identify the dynamic buckling mechanism that produces flicks in Vibrio alginolyticus. Estimates of forces and torques on the hook from experimental observations suggest that flicks are triggered at stresses below the hook's static Euler buckling criterion. Using an accurate linearization of the Kirchoff rod model for the hook in a model of a swimming bacterium with rigid flagellum, we show that as hook stiffness decreases there is a transition from on-axis flagellar rotation with small hook deflections to flagellar precession with large deflections. When flagellum flexibility is incorporated, the precession is disrupted by significant flagellar bending - i.e., incipient flicks. The predicted onset of dynamic instabilities corresponds well with experimentally observed flick events.
A theory for the fracture of thin plates subjected to bending and twisting moments
NASA Technical Reports Server (NTRS)
Hui, C. Y.; Zehnder, Alan T.
1993-01-01
Stress fields near the tip of a through crack in an elastic plate under bending and twisting moments are reviewed assuming both Kirchhoff and Reissner plate theories. The crack tip displacement and rotation fields based on the Reissner theory are calculated. These results are used to calculate the J-integral (energy release rate) for both Kirchhoff and Reissner plate theories. Invoking Simmonds and Duva's (1981) result that the value of the J-integral based on either theory is the same for thin plates, a universal relationship between the Kirchhoff theory stress intensity factors and the Reissner theory stress intensity factors is obtained for thin plates. Calculation of Kirchhoff theory stress intensity factors from finite elements based on energy release rate is illustrated. It is proposed that, for thin plates, fracture toughness and crack growth rates be correlated with the Kirchhoff theory stress intensity factors.
Quantum monodromy and quantum phase transitions in floppy molecules
NASA Astrophysics Data System (ADS)
Larese, Danielle
2012-10-01
A simple algebraic Hamiltonian has been used to explore the vibrational and rotational spectra of the skeletal bending modes of HCNO, BrCNO, NCNCS, and other "floppy" (quasi-linear or quasi-bent) molecules. These molecules have large-amplitude, low-energy bending modes and champagne-bottle potential surfaces, making them good candidates for observing quantum phase transitions (QPT). We describe the geometric phase transitions from bent to linear in these and other non-rigid molecules, quantitatively analyzing the spectroscopic signatures of ground state QPT, excited state QPT, and quantum monodromy. The algebraic framework is ideal for this work because of its small calculational effort yet robust results. Although these methods have historically found success with tri-and four-atomic molecules, we now address five-atomic and simple branched molecules such as CH3NCO and GeH3NCO. Extraction of potential functions are completed for several molecules, resulting in predictions of barriers to linearity and equilibrium bond angles.
Tunable broadband unidirectional acoustic transmission based on a waveguide with phononic crystal
NASA Astrophysics Data System (ADS)
Song, Ailing; Chen, Tianning; Wang, Xiaopeng; Wan, Lele
2016-08-01
In this paper, a tunable broadband unidirectional acoustic transmission (UAT) device composed of a bended tube and a superlattice with square columns is proposed and numerically investigated by using finite element method. The UAT is realized in the proposed UAT device within two wide frequency ranges. And the effectiveness of the UAT device is demonstrated by analyzing the sound pressure distributions when the acoustic waves are incident from different directions. The unidirectional band gaps can be effectively tuned by mechanically rotating the square columns, which is a highlight of this paper. Besides, a bidirectional acoustic isolation (BAI) device is obtained by placing two superlattices in the bended tube, in which the acoustic waves cannot propagate along any directions. The physical mechanisms of the proposed UAT device and BAI device are simply discussed. The proposed models show potential applications in some areas, such as unidirectional sonic barrier or noise insulation.
Simplified analysis of a generalized bias test for fabrics with two families of inextensible fibres
NASA Astrophysics Data System (ADS)
Cuomo, M.; dell'Isola, F.; Greco, L.
2016-06-01
Two tests for woven fabrics with orthogonal fibres are examined using simplified kinematic assumptions. The aim is to analyse how different constitutive assumptions may affect the response of the specimen. The fibres are considered inextensible, and the kinematics of 2D continua with inextensible chords due to Rivlin is adopted. In addition to two forms of strain energy depending on the shear deformation, also two forms of energy depending on the gradient of shear are examined. It is shown that this energy can account for the bending of the fibres. In addition to the standard bias extension test, a modified test has been examined, in which the head of the specimen is rotated rather than translated. In this case more bending occurs, so that the results of the simulation carried out with the different energy models adopted differ more that what has been found for the BE test.
Magnetic Torque in Single Crystal Ni-Mn-Ga
NASA Astrophysics Data System (ADS)
Hobza, Anthony; Müllner, Peter
2017-06-01
Magnetic shape memory alloys deform in an external magnetic field in two distinct ways: by axial straining—known as magnetic-field-induced strain—and by bending when exposed to torque. Here, we examine the magnetic torque that a magnetic field exerts on a long Ni-Mn-Ga rod. A single crystal specimen of Ni-Mn-Ga was constrained with respect to bending and subjected to an external magnetic field. The torque required to rotate the specimen in the field was measured as a function of the orientation of the sample with the external magnetic field, strain, and the magnitude of the external magnetic field. The torque was analyzed based on the changes in the free energy with the angle between the field and the sample. The contributions of magnetocrystalline anisotropy and shape anisotropy to the Zeeman energy determine the net torque. The torque is large when magneotcrystalline and shape anisotropies act synergistically and small when these anisotropies act antagonistically.
Lai, WeiJen; Midorikawa, Yoshiyuki; Kanno, Zuisei; Takemura, Hiroshi; Suga, Kazuhiro; Soga, Kohei; Ono, Takashi; Uo, Motohiro
2016-12-01
We developed a device to evaluate the orthodontic force applied by systems requiring high operability. A life-sized, two-tooth model was designed, and the measurements were performed using a custom-made jointed attachment, referred to as an "action stick", to allow clearance for the oversized six-axis sensors. This tooth-sensor apparatus was accurately calibrated, and the error was limited. Vector analysis and rotating coordinate transformation were required to derive the force and moment at the tooth from the sensor readings. The device was then used to obtain measurements of the force and moment generated by the V-bend system. Our device was effective, providing results that were consistent with those of previous studies. This measurement device can be manufactured with force sensors of any size, and it can also be expanded to models with any number of teeth.
Empirical resistive-force theory for slender biological filaments in shear-thinning fluids
NASA Astrophysics Data System (ADS)
Riley, Emily E.; Lauga, Eric
2017-06-01
Many cells exploit the bending or rotation of flagellar filaments in order to self-propel in viscous fluids. While appropriate theoretical modeling is available to capture flagella locomotion in simple, Newtonian fluids, formidable computations are required to address theoretically their locomotion in complex, nonlinear fluids, e.g., mucus. Based on experimental measurements for the motion of rigid rods in non-Newtonian fluids and on the classical Carreau fluid model, we propose empirical extensions of the classical Newtonian resistive-force theory to model the waving of slender filaments in non-Newtonian fluids. By assuming the flow near the flagellum to be locally Newtonian, we propose a self-consistent way to estimate the typical shear rate in the fluid, which we then use to construct correction factors to the Newtonian local drag coefficients. The resulting non-Newtonian resistive-force theory, while empirical, is consistent with the Newtonian limit, and with the experiments. We then use our models to address waving locomotion in non-Newtonian fluids and show that the resulting swimming speeds are systematically lowered, a result which we are able to capture asymptotically and to interpret physically. An application of the models to recent experimental results on the locomotion of Caenorhabditis elegans in polymeric solutions shows reasonable agreement and thus captures the main physics of swimming in shear-thinning fluids.
Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments.
Ninan, Elizabeth; Berzins, David W
2013-01-01
Recently introduced into the market are shape memory nickel-titanium (NiTi) rotary files. The objective of this study was to investigate the torsion and bending properties of shape memory files (CM Wire, HyFlex CM, and Phoenix Flex) and compare them with conventional (ProFile ISO and K3) and M-Wire (GT Series X and ProFile Vortex) NiTi files. Sizes 20, 30, and 40 (n = 12/size/taper) of 0.02 taper CM Wire, Phoenix Flex, K3, and ProFile ISO and 0.04 taper HyFlex CM, ProFile ISO, GT Series X, and Vortex were tested in torsion and bending per ISO 3630-1 guidelines by using a torsiometer. All data were statistically analyzed by analysis of variance and the Tukey-Kramer test (P = .05) to determine any significant differences between the files. Significant interactions were present among factors of size and file. Variability in maximum torque values was noted among the shape memory files brands, sometimes exhibiting the greatest or least torque depending on brand, size, and taper. In general, the shape memory files showed a high angle of rotation before fracture but were not statistically different from some of the other files. However, the shape memory files were more flexible, as evidenced by significantly lower bending moments (P < .008). Shape memory files show greater flexibility compared with several other NiTi rotary file brands. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
2015-01-01
Background It has been thought that corrective posterior surgery for adolescent idiopathic scoliosis (AIS) should be started on the concave side because initial convex manipulation would increase the risk of vertebral malrotation, worsening the rib hump. With the many new materials, implants, and manipulation techniques (e.g., direct vertebral rotation) now available, we hypothesized that manipulating the convex side first is no longer taboo. Methods Our technique has two major facets. (1) Curve correction is started from the convex side with a derotation maneuver and in situ bending followed by concave rod application. (2) A 6.35 mm diameter pure titanium rod is used on the convex side and a 6.35 mm diameter titanium alloy rod on the concave side. Altogether, 52 patients were divided into two groups. Group N included 40 patients (3 male, 37 female; average age 15.9 years) of Lenke type 1 (23 patients), type 2 (2), type 3 (3), type 5 (10), type 6 (2). They were treated with a new technique using 6.35 mm diameter different-stiffness titanium rods. Group C included 12 patients (all female, average age 18.8 years) of Lenke type 1 (6 patients), type 2 (3), type 3 (1), type 5 (1), type 6 (1). They were treated with conventional methods using 5.5 mm diameter titanium alloy rods. Radiographic parameters (Cobb angle/thoracic kyphosis/correction rates) and perioperative data were retrospectively collected and analyzed. Results Preoperative main Cobb angles (groups N/C) were 56.8°/60.0°, which had improved to 15.2°/17.1° at the latest follow-up. Thoracic kyphosis increased from 16.8° to 21.3° in group N and from 16.0° to 23.4° in group C. Correction rates were 73.2% in group N and 71.7% in group C. There were no significant differences for either parameter. Mean operating time, however, was significantly shorter in group N (364 min) than in group C (456 min). Conclusion We developed a new corrective surgical technique for AIS using a 6.35 mm diameter pure titanium rod initially on the convex side. Correction rates in the coronal, sagittal, and axial planes were the same as those achieved with conventional methods, but the operation time was significantly shorter. PMID:25815053
An image registration based ultrasound probe calibration
NASA Astrophysics Data System (ADS)
Li, Xin; Kumar, Dinesh; Sarkar, Saradwata; Narayanan, Ram
2012-02-01
Reconstructed 3D ultrasound of prostate gland finds application in several medical areas such as image guided biopsy, therapy planning and dose delivery. In our application, we use an end-fire probe rotated about its axis to acquire a sequence of rotational slices to reconstruct 3D TRUS (Transrectal Ultrasound) image. The image acquisition system consists of an ultrasound transducer situated on a cradle directly attached to a rotational sensor. However, due to system tolerances, axis of probe does not align exactly with the designed axis of rotation resulting in artifacts in the 3D reconstructed ultrasound volume. We present a rigid registration based automatic probe calibration approach. The method uses a sequence of phantom images, each pair acquired at angular separation of 180 degrees and registers corresponding image pairs to compute the deviation from designed axis. A modified shadow removal algorithm is applied for preprocessing. An attribute vector is constructed from image intensity and a speckle-insensitive information-theoretic feature. We compare registration between the presented method and expert-corrected images in 16 prostate phantom scans. Images were acquired at multiple resolutions, and different misalignment settings from two ultrasound machines. Screenshots from 3D reconstruction are shown before and after misalignment correction. Registration parameters from automatic and manual correction were found to be in good agreement. Average absolute differences of translation and rotation between automatic and manual methods were 0.27 mm and 0.65 degree, respectively. The registration parameters also showed lower variability for automatic registration (pooled standard deviation σtranslation = 0.50 mm, σrotation = 0.52 degree) compared to the manual approach (pooled standard deviation σtranslation = 0.62 mm, σrotation = 0.78 degree).
NASA Astrophysics Data System (ADS)
Metois, M.
2017-12-01
Convergence partitioning between subduction zones and crustal active structures has been widely evidenced. For instance, the convergence between the Indian and Sunda plates is accommodated both by the Sumatra subduction zone and the Great Sumatran strike-slip fault, that defines a narrow sliver. In Cascadia, small-scale rotating rigid blocks bounded by active faults have been proposed (e.g. McCaffrey et al. 2007). Recent advances in geodetic measurements along the South-American margin especially in Ecuador, Peru and Chile and the need for precise determination of the coupling amount on the megathrust interface in particular for seismic hazard assessment, led several authors to propose the existence of large-scale Andean slivers rotating clockwise and counter-clockwise South and North of the Arica bend, respectively (e.g. Chlieh et al. 2011, Nocquet et al. 2014, Métois et al. 2013). In Chile, one single large Andean sliver bounded to the west by the subduction thrust and to the east by the subandean fold-an-thrust belt active front is used to mimic the velocities observed in the middle to far field that are misfitted by elastic coupling models on the megathrust interface alone (Métois et al. 2016). This rigid sliver is supposed to rotate clockwise around a Euler pole located in the South Atlantic ocean, consistently with long-term observed rotations detected by paleomagnetism (e.g. Arriagada et al. 2008). However, recent GPS data acquired in the Taltal area ( 26°S, Klein et al. submitted) show higher than expected middle-field eastward velocities and question the first-order assumption of a rigid Andean sliver. Mis-modeling the fore-arc deformation has a direct impact on the inverted coupling amount and distribution, and could therefore bias significantly the megathrust rupture scenarios. Correctly estimating the current-day deformation of the Andes is therefore required to properly assess for coupling on the plate interface and is challenging since crustal active structures are often hidden by the intense seismic activity of the subduction zone. Here we discuss the validity of the rigid Andean sliver hypothesis based on GPS velocities, present alternative models for both coupling and sliver kinematics along the Chilean margin, and discuss the relationship between upper plate long and short-term deformation.
Compliant hydrodynamic fluid journal bearing
NASA Technical Reports Server (NTRS)
Warren, E. L. (Inventor)
1985-01-01
An air bearing structure is described that prevents destructive bending moments within the top foil. Welds are eliminated by mounting the top bearing foil in the bearing cartridge sleeve without using a space block. Tabs or pins at the end of the top bearing foil are restrained by slots or stops formed in the cartridge sleeve. These structural members are free to move in a direction normal to the shaft while being restrained from movement in the direction of shaft rotation.
All-optical, Three-axis Fiber Laser Magnetometer
2012-04-16
into each core using an ultraviolet laser. Measurements of the differences in induced strain between the FBGs enables bending in two dimensions to...housing. This is repeated for multiple inclinations. The difference in strain between two FBGs as a function of rotation for three inclination...angles of 9°, 45°, and 81° is shown in Fig. 10(a). The FBG strain is measured using an interferometric method, and as such, the difference in strain is
Field Artillery Cannon Weapons Systems and Ammunition Handbook.
1983-02-01
ground. I (2) When the weapon is emplaced on uneven terrain, the equalizing support rotates on the horizontal pivot pin, placing the tilting parts of the...intervisible. g. Direct fire-Fire from a weapon that is laid by sighting directly on the target. h. Cant-The tilting of the trunnions of the weapon...locking handle bends or breaks because excess mucle is applied. The screws vibrate loose and are lost because somebody forgets to check them for
Joyce, Christopher; Chivers, Paola; Sato, Kimitake; Burnett, Angus
2016-10-01
The use of multi-segment trunk models to investigate the crunch factor in golf may be warranted. The first aim of the study was to investigate the relationship between the trunk and lower trunk for crunch factor-related variables (trunk lateral bending and trunk axial rotation velocity). The second aim was to determine the level of association between crunch factor-related variables with swing (clubhead velocity) and launch (launch angle). Thirty-five high-level amateur male golfers (Mean ± SD: age = 23.8 ± 2.1 years, registered golfing handicap = 5 ± 1.9) without low back pain had kinematic data collected from their golf swing using a 10-camera motion analysis system operating at 500 Hz. Clubhead velocity and launch angle were collected using a validated real-time launch monitor. A positive relationship was found between the trunk and lower trunk for axial rotation velocity (r(35) = .47, P < .01). Cross-correlation analysis revealed a strong coupling relationship for the crunch factor (R(2) = 0.98) between the trunk and lower trunk. Using generalised linear model analysis, it was evident that faster clubhead velocities and lower launch angles of the golf ball were related to reduced lateral bending of the lower trunk.
Campa-Moran, Irene; Rey-Gudin, Etelvina; Fernández-Carnero, Josué; Paris-Alemany, Alba; Gil-Martinez, Alfonso; Lerma Lara, Sergio; Prieto-Baquero, Almudena; Alonso-Perez, José Luis; La Touche, Roy
2015-01-01
Objective. The aim of this study was to compare the efficacy of three interventions for the treatment of myofascial chronic neck pain. Methods. Thirty-six patients were randomly assigned to one of three intervention groups: orthopedic manual therapy (OMT), dry needling and stretching (DN-S), and soft tissue techniques (STT). All groups received two treatment sessions with a 48 h time interval. Outcome measures included neck pain intensity measured using a visual analogue scale, cervical range of motion (ROM), pressure pain threshold for measuring mechanical hyperalgesia, and two self-reported questionnaires (neck disability index and pain catastrophizing scale). Results. The ANOVA revealed significant differences for the group × time interaction for neck disability, neck pain intensity, and pain catastrophizing. The DN-S and OMT groups reduced neck disability. Only the OMT group showed decreases in mechanical hyperalgesia and pain catastrophizing. The cervical ROM increased in OMT (i.e., flexion, side-bending, and rotation) and DN-S (i.e., side-bending and rotation) groups. Conclusions. The three interventions are all effective in reducing pain intensity. Reduction in mechanical hyperalgesia and pain catastrophizing was only observed in the OMT group. Cervical ROM improved in the DN-S and OMT groups and also neck disability being only clinically relevant for OMT group. PMID:26640708
Lindsey, Derek P; Perez-Orribo, Luis; Rodriguez-Martinez, Nestor; Reyes, Phillip M; Newcomb, Anna; Cable, Alexandria; Hickam, Grace; Yerby, Scott A; Crawford, Neil R
2014-01-01
Introduction Sacroiliac (SI) joint pain has become a recognized factor in low back pain. The purpose of this study was to investigate the effect of a minimally invasive surgical SI joint fusion procedure on the in vitro biomechanics of the SI joint before and after cyclic loading. Methods Seven cadaveric specimens were tested under the following conditions: intact, posterior ligaments (PL) and pubic symphysis (PS) cut, treated (three implants placed), and after 5,000 cycles of flexion–extension. The range of motion (ROM) in flexion–extension, lateral bending, and axial rotation was determined with an applied 7.5 N · m moment using an optoelectronic system. Results for each ROM were compared using a repeated measures analysis of variance (ANOVA) with a Holm–Šidák post-hoc test. Results Placement of three fusion devices decreased the flexion–extension ROM. Lateral bending and axial rotation were not significantly altered. All PL/PS cut and post-cyclic ROMs were larger than in the intact condition. The 5,000 cycles of flexion–extension did not lead to a significant increase in any ROMs. Discussion In the current model, placement of three 7.0 mm iFuse Implants significantly decreased the flexion–extension ROM. Joint ROM was not increased by 5,000 flexion–extension cycles. PMID:24868175
Helicopter rotor blade frequency evolution with damage growth and signal processing
NASA Astrophysics Data System (ADS)
Roy, Niranjan; Ganguli, Ranjan
2005-05-01
Structural damage in materials evolves over time due to growth of fatigue cracks in homogenous materials and a complicated process of matrix cracking, delamination, fiber breakage and fiber matrix debonding in composite materials. In this study, a finite element model of the helicopter rotor blade is used to analyze the effect of damage growth on the modal frequencies in a qualitative manner. Phenomenological models of material degradation for homogenous and composite materials are used. Results show that damage can be detected by monitoring changes in lower as well as higher mode flap (out-of-plane bending), lag (in-plane bending) and torsion rotating frequencies, especially for composite materials where the onset of the last stage of damage of fiber breakage is most critical. Curve fits are also proposed for mathematical modeling of the relationship between rotating frequencies and cycles. Finally, since operational data are noisy and also contaminated with outliers, denoising algorithms based on recursive median filters and radial basis function neural networks and wavelets are studied and compared with a moving average filter using simulated data for improved health-monitoring application. A novel recursive median filter is designed using integer programming through genetic algorithm and is found to have comparable performance to neural networks with much less complexity and is better than wavelet denoising for outlier removal. This filter is proposed as a tool for denoising time series of damage indicators.
Backlash compensator mechanism
Chrislock, Jerry L.
1979-01-01
Mechanism which compensates for backlash error in a lead screw position indicator by decoupling the indicator shaft from the lead screw when reversing rotation. The position indicator then displays correct information regardless of the direction of rotation of the lead screw.
Gross, Daniel J; Golijanin, Petar; Dumont, Guillaume D; Parada, Stephen A; Vopat, Bryan G; Reinert, Steven E; Romeo, Anthony A; Provencher, C D R Matthew T
2016-01-01
Computed tomography (CT) scans of the shoulder are often not well aligned to the axis of the scapula and glenoid. The purpose of this paper was to determine the effect of sagittal rotation of the glenoid on axial measurements of anterior-posterior (AP) glenoid width and glenoid version attained by standard CT scan. In addition, we sought to define the angle of rotation required to correct the CT scan to optimal positioning. A total of 30 CT scans of the shoulder were reformatted using OsiriX software multiplanar reconstruction. The uncorrected (UNCORR) and corrected (CORR) CT scans were compared for measurements of both (1) axial AP glenoid width and (2) glenoid version at 5 standardized axial cuts. The mean difference in glenoid version was 2.6% (2° ± 0.1°; P = .0222) and the mean difference in AP glenoid width was 5.2% (1.2 ± 0.42 mm; P = .0026) in comparing the CORR and UNCORR scans. The mean angle of correction required to align the sagittal plane was 20.1° of rotation (range, 9°-39°; standard error of mean, 1.2°). These findings demonstrate that UNCORR CT scans of the glenohumeral joint do not correct for the sagittal rotation of the glenoid, and this affects the characteristics of the axial images. Failure to align the sagittal image to the 12-o'clock to 6-o'clock axis results in measurement error in both glenoid version and AP glenoid width. Use of UNCORR CT images may have notable implications for decision-making and surgical treatment. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Structure and conformational states of the bovine mitochondrial ATP synthase by cryo-EM
Zhou, Anna; Rohou, Alexis; Schep, Daniel G; Bason, John V; Montgomery, Martin G; Walker, John E; Grigorieff, Nikolaus; Rubinstein, John L
2015-01-01
Adenosine triphosphate (ATP), the chemical energy currency of biology, is synthesized in eukaryotic cells primarily by the mitochondrial ATP synthase. ATP synthases operate by a rotary catalytic mechanism where proton translocation through the membrane-inserted FO region is coupled to ATP synthesis in the catalytic F1 region via rotation of a central rotor subcomplex. We report here single particle electron cryomicroscopy (cryo-EM) analysis of the bovine mitochondrial ATP synthase. Combining cryo-EM data with bioinformatic analysis allowed us to determine the fold of the a subunit, suggesting a proton translocation path through the FO region that involves both the a and b subunits. 3D classification of images revealed seven distinct states of the enzyme that show different modes of bending and twisting in the intact ATP synthase. Rotational fluctuations of the c8-ring within the FO region support a Brownian ratchet mechanism for proton-translocation-driven rotation in ATP synthases. DOI: http://dx.doi.org/10.7554/eLife.10180.001 PMID:26439008
Dolan, P; Adams, M A
1998-08-01
During manual handling, the back muscles protect the spine from excessive flexion, but in doing so impose a high compressive force on it. Epidemiological links between back pain and repetitive lifting suggest that fatigued muscles may adversely affect the balance between bending and compression. Fifteen volunteers lifted and lowered a 10 kg weight from floor to waist height 100 times. Throughout this task, the bending moment acting on the osteoligamentous lumbar spine was estimated from continuous measurements of lumbar flexion, obtained using the 3-Space Isotrak. Spinal compression was estimated from the electromyographic (EMG) activity of the erector spinae muscles, recorded from skin-surface electrodes at the levels of T10 and L3. EMG signals were calibrated against force when subjects pulled up on a load cell, and correction factors were applied to account for changes in muscle length and contraction velocity. Fatigue in the erector spinae muscles was quantified by comparing the frequency content of their EMG signal during static contractions performed before, and immediately after, the 100 lifts. Results showed that peak lumbar flexion increased during the 100 lifts from 83.3 +/- 14.8% to 90.4 +/- 14.3%, resulting in a 36% increase in estimated peak bending moment acting on the lumbar spine (P = 0.008). Peak spinal compression fell by 11% (p = 0.007). The median frequency of the EMG signal at L3 decreased by 5.5% following the 100 lifts (p = 0.042) confirming that the erector spinae were fatigued, but measures of fatigue showed no significant correlation with increased bending. We conclude that repetitive lifting induces measurable fatigue in the erector spinae muscles, and substantially increases the bending moment acting on the lumbar spine.
Method for Correcting Control Surface Angle Measurements in Single Viewpoint Photogrammetry
NASA Technical Reports Server (NTRS)
Burner, Alpheus W. (Inventor); Barrows, Danny A. (Inventor)
2006-01-01
A method of determining a corrected control surface angle for use in single viewpoint photogrammetry to correct control surface angle measurements affected by wing bending. First and second visual targets are spaced apart &om one another on a control surface of an aircraft wing. The targets are positioned at a semispan distance along the aircraft wing. A reference target separation distance is determined using single viewpoint photogrammetry for a "wind off condition. An apparent target separation distance is then computed for "wind on." The difference between the reference and apparent target separation distances is minimized by recomputing the single viewpoint photogrammetric solution for incrementally changed values of target semispan distances. A final single viewpoint photogrammetric solution is then generated that uses the corrected semispan distance that produced the minimized difference between the reference and apparent target separation distances. The final single viewpoint photogrammetric solution set is used to determine the corrected control surface angle.
Inducer Hydrodynamic Load Measurement Devices
NASA Technical Reports Server (NTRS)
Skelley, Stephen E.; Zoladz, Thomas F.
2002-01-01
Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.
Inducer Hydrodynamic Load Measurement Devices
NASA Technical Reports Server (NTRS)
Skelley, Stephen E.; Zoladz, Thomas F.; Turner, Jim (Technical Monitor)
2002-01-01
Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher-frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.
Posturography of ataxia induced by Coriolis- and Purkinje-effects.
Fitger, C; Brandt, T
1982-02-01
Vestibular Coriolis- and Purkinje-effect, which are known to induce vertigo, were investigated with respect to body posture. One aim of this investigation was to provide information concerning clinical vertigo symptoms. Standing on a rotatable stabilometer, 25 healthy subjects had to execute lateral head tilts during (Coriolis), or after (Purkinje), rotation varied with different constant velocities. The conditions were varied with respect to eyes open vs. eyes closed, head upright vs. head tilt to the right and left, direction of rotation clockwise vs. counterclockwise, active vs. passive head tilt, and active vs. passive body rotation. The results supported the expectation that destabilization was less severe with open than with closed eyes and that sway amplitudes were increased after head tilt as well as with a higher velocity of rotation. The direction of the induced body shift was, as expected, opposite to the initial vestibular stimulus. A forward shift after stop without head tilt was frequently found, being independent of the previous direction of rotation. Reported perceptions coincided mostly not with the initial vestibular signal but rather with the actual movement of compensation. Active instead of passive movements did not produce clearly different effects. The Purkinje experiment appeared to be equivalent to the situation when a patient with an acute lesion of a horizontal vestibular canal bends his head. The stabilogram under this condition may allow a prediction of the side of the lesion.
Chasing the Garlock: A study of tectonic response to vertical axis rotation
NASA Astrophysics Data System (ADS)
Guest, Bernard; Pavlis, Terry L.; Golding, Heather; Serpa, Laura
2003-06-01
Vertical-axis, clockwise block rotations in the Northeast Mojave block are well documented by numerous authors. However, the effects of these rotations on the crust to the north of the Northeast Mojave block have remained unexplored. In this paper we present a model that results from mapping and geochronology conducted in the north and central Owlshead Mountains. The model suggests that some or all of the transtension and rotation observed in the Owlshead Mountains results from tectonic response to a combination of clockwise block rotation in the Northeast Mojave block and Basin and Range extension. The Owlshead Mountains are effectively an accommodation zone that buffers differential extension between the Northeast Mojave block and the Basin and Range. In addition, our model explores the complex interactions that occur between faults and fault blocks at the junction of the Garlock, Brown Mountain, and Owl Lake faults. We hypothesize that the bending of the Garlock fault by rotation of the Northeast Mojave block resulted in a misorientation of the Garlock that forced the Owl Lake fault to break in order to accommodate slip on the western Garlock fault. Subsequent sinistral slip on the Owl Lake fault offset the Garlock, creating the now possibly inactive Mule Springs strand of the Garlock fault. Dextral slip on the Brown Mountain fault then locked the Owl Lake fault, forcing the active Leach Lake strand of the Garlock fault to break.
Chrystal, C; Burrell, K H; Grierson, B A; Groebner, R J; Kaplan, D H
2012-10-01
To improve poloidal rotation measurement capabilities on the DIII-D tokamak, new chords for the charge exchange recombination spectroscopy (CER) diagnostic have been installed. CER is a common method for measuring impurity rotation in tokamak plasmas. These new chords make measurements on the high-field side of the plasma. They are designed so that they can measure toroidal rotation without the need for the calculation of atomic physics corrections. Asymmetry between toroidal rotation on the high- and low-field sides of the plasma is used to calculate poloidal rotation. Results for the main impurity in the plasma are shown and compared with a neoclassical calculation of poloidal rotation.
Mueller, Maike; Hoy, Gregory; Branson, Ruben
2016-01-01
Introduction Professional sports injuries are usually all dealt with at one single operation to return the player to the sport after appropriate rehabilitation. We questioned the assumption that rotator cuff tears must be repaired concurrently with instability syndromes, and aimed to allow a professional rugby league player to achieve career goals by NOT correcting all pathology at one surgery. Case Presentation A professional rugby league player presented with acute shoulder instability on a setting of a chronic full thickness rotator cuff tear. We performed an “in season” arthroscopic stabilization on an elite rugby league player, leaving a previously diagnosed large full thickness rotator cuff tear untreated. This allowed aggressive rehabilitation and return to contact competition at 12 weeks post-surgery. The player achieved a long held career goal of winning a premiership ring before undertaking rotator cuff repair at the end of the season. Latest follow up at seven years (still at elite level) demonstrated an asymptomatic shoulder. Conclusions The assumption that all pathology found at surgical exploration requires correction to play at elite level is not universally correct. We postulate that whilst rotator cuff deficiency has severe long-term sequelae, it is shoulder instability alone that prevents high level contact sports participation. Career goal management is an important part of managing elite level athletes. We have demonstrated that by careful management of the specific pathology preventing participation can allow elite athletes to achieve career goals without compromising long-term health. PMID:27217928
Contact pressure in the facet joint during sagittal bending of the cadaveric cervical spine.
Jaumard, Nicolas V; Bauman, Joel A; Weisshaar, Christine L; Guarino, Benjamin B; Welch, William C; Winkelstein, Beth A
2011-07-01
The facet joint contributes to the normal biomechanical function of the spine by transmitting loads and limiting motions via articular contact. However, little is known about the contact pressure response for this joint. Such information can provide a quantitative measure of the facet joint's local environment. The objective of this study was to measure facet pressure during physiologic bending in the cervical spine, using a joint capsule-sparing technique. Flexion and extension bending moments were applied to six human cadaveric cervical spines. Global motions (C2-T1) were defined using infra-red cameras to track markers on each vertebra. Contact pressure in the C5-C6 facet was also measured using a tip-mounted pressure transducer inserted into the joint space through a hole in the postero-inferior region of the C5 lateral mass. Facet contact pressure increased by 67.6 ± 26.9 kPa under a 2.4 Nm extension moment and decreased by 10.3 ± 9.7 kPa under a 2.7 Nm flexion moment. The mean rotation of the overall cervical specimen motion segments was 9.6 ± 0.8° and was 1.6 ± 0.7° for the C5-C6 joint, respectively, for extension. The change in pressure during extension was linearly related to both the change in moment (51.4 ± 42.6 kPa/Nm) and the change in C5-C6 angle (18.0 ± 108.9 kPa/deg). Contact pressure in the inferior region of the cervical facet joint increases during extension as the articular surfaces come in contact, and decreases in flexion as the joint opens, similar to reports in the lumbar spine despite the difference in facet orientation in those spinal regions. Joint contact pressure is linearly related to both sagittal moment and spinal rotation. Cartilage degeneration and the presence of meniscoids may account for the variation in the pressure profiles measured during physiologic sagittal bending. This study shows that cervical facet contact pressure can be directly measured with minimal disruption to the joint and is the first to provide local pressure values for the cervical joint in a cadaveric model.
Koh, Y-G.; Son, J.; Kwon, S-K.; Kim, H-J.; Kang, K-T.
2017-01-01
Objectives Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1. PMID:28947604
Laws, Cory J; Coughlin, Dezba G; Lotz, Jeffrey C; Serhan, Hassan A; Hu, Serena S
2012-05-01
A human cadaveric biomechanical study of lumbar mobility before and after fusion and with or without supplemental instrumentation for 5 instrumentation configurations. To determine the biomechanical differences between anterior lumbar interbody fusion (ALIF) and direct lateral interbody fusion (DLIF) with and without supplementary instrumentation. Some prior studies have compared various surgical approaches using the same interbody device whereas others have investigated the stabilizing effect of supplemental instrumentation. No published studies have performed a side-by-side comparison of standard and minimally invasive techniques with and without supplemental instrumentation. Eight human lumbosacral specimens (16 motion segments) were tested in each of the 5 following configurations: (1) intact, (2) with ALIF or DLIF cage, (3) with cage plus stabilizing plate, (4) with cage plus unilateral pedicle screw fixation (PSF), and (5) with cage plus bilateral PSF. Pure moments were applied to induce specimen flexion, extension, lateral bending, and axial rotation. Three-dimensional kinematic responses were measured and used to calculate range of motion, stiffness, and neutral zone. Compared to the intact state, DLIF significantly reduced range of motion in flexion, extension, and lateral bending (P = 0.0117, P = 0.0015, P = 0.0031). Supplemental instrumentation significantly increased fused-specimen stiffness for both DLIF and ALIF groups. For the ALIF group, bilateral PSF increased stiffness relative to stand-alone cage by 455% in flexion and 317% in lateral bending (P = 0.0009 and P < 0.0001). The plate increased ALIF group stiffness by 211% in extension and 256% in axial rotation (P = 0.0467 and P = 0.0303). For the DLIF group, bilateral PSF increased stiffness by 350% in flexion and 222% in extension (P < 0.0001 and P = 0.0008). No differences were observed between ALIF and DLIF groups supplemented with bilateral PSF. Our data support that the direct lateral approach, when supplemented with bilateral PSF, is a minimally invasive and biomechanically stable alternative to the open, anterior approach to lumbar spine fusion.