Science.gov

Sample records for bepc ii positron

  1. Upgrade of beam energy measurement system at BEPC-II

    NASA Astrophysics Data System (ADS)

    Zhang, Jian-Yong; Cai, Xiao; Mo, Xiao-Hu; Guo, Di-Zhou; Wang, Jian-Li; Liu, Bai-Qi; Achasov, M. N.; Krasnov, A. A.; Muchnoi, N. Yu.; Pyata, E. E.; Mamoshkina, E. V.; Harris, F. A.

    2016-07-01

    The beam energy measurement system is of great importance for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. In order to meet the requirements of data taking and improve the measurement accuracy, the system has continued to be upgraded, which involves the updating of laser and optics subsystems, replacement of a view-port of the laser to the vacuum insertion subsystem, the use of an electric cooling system for a high purity germanium detector, and improvement of the data acquisition and processing subsystem. The upgrade system guarantees the smooth and efficient measurement of beam energy at BEPC-II and enables accurate offline energy values for further physics analysis at BES-III. Supported in part by National Natural Science Foundation of China (NSFC)(11375206, 10775142, 10825524, 11125525, 11235011), the Ministry of Science and Technology of China (2015CB856700, 2015CB856705), State key laboratory of particle and detection and electronics; and the CAS Center for Excellence in Particle Physics (CCEPP); the RFBR grant(14-02-00129-a), U.S. Department of Energy (DE-FG02-04ER41291, DE-FG02-05ER41374, DE-FG02-94ER40823, DESC0010118), U.S. National Science Foundation, part of this work related to the design of ZnSe viewports is supported by the Russian Science Foundation (14-50-00080)

  2. DETECTORS AND EXPERIMENTAL METHODS: Online measurement of the BEPC II background using RadFET dosimeters

    NASA Astrophysics Data System (ADS)

    Gong, Hui; Li, Jin; Gong, Guang-Hua; Li, Yu-Xiong; Hou, Lei; Shao, Bei-Bei

    2009-09-01

    To monitor the integral dose deposited in the BESIII electromagnetic calorimeter whose performance degrades due to exposure to the BEPC II background, a 400 nm IMPL RadFET dosimeter-based integral dose online monitor system is built. After calibration with the 60Co source and verification with TLD in the pulse radiation fields, an experiment was arranged to measure the BEPC II background online. The results are presented.

  3. CRYOGENIC FACITLITY DESIGN IN BEPC II SUPERCONDUCTING UPGRADE.

    SciTech Connect

    JIA,L.X.; WANG,L.; YANG,G.D.; ET AL.

    2004-05-11

    Three kinds of superconducting device are to be constructed at interaction regions in the upgrade of Beijing Electron-Positron Collider (BEPCII). Two sets of refrigerators with each capacity of 500W at 4.5K are adopted to provide the refrigeration for them. The cryogenic systems to support the operation of the superconducting facilities are under design by Harbin Institute of Technology in China. This paper presents the current design of main cryogenic facilities.

  4. COMPUTATIONAL SIMULATION OF REFRIGERATION PROCESS FOR BEPC II SUPERCONDUCTING FACILITIES.

    SciTech Connect

    WANG,L.JIA,L.X.DU,H.P.YANG,G.D.

    2003-09-22

    The main challenge to build the cryogenic system for the Beijing Electron-Positron Collider Upgrade is to accommodate the strong differences among three types of superconducting devices with regard to their structure, location, as well as the cryogenic operating requirement. Three kinds of cooling methods are applied in the overall cryogenic system, saturated liquid helium cooling for the SRF cavities, single-phase helium cooling for the SCQ magnets, and two-phase helium cooling for the SSM solenoid. The optimization for the BEPCII cryogenic system was carried out by using a large-scale computational simulation package. This paper presents thermal parameters and numerical analyses for the BEPCII cryogenic system.

  5. Tsung-Dao Lee and BEPC

    NASA Astrophysics Data System (ADS)

    Zheng, Zhipeng

    2017-03-01

    The scientific world is well aware of Prof. Tsung-Dao Lee’s contribution to the Beijing Electron-Positron Collider (BEPC). At this time, between his ninetieth birthday and the sixtieth anniversary of the discovery of parity violation, as one of those involved in building the BEPC, I would like to recall some of the history around the construction of the BEPC, to discuss T. D. Lee’s key role in the process and show his passion for science in China.

  6. Monoenergetic positron beam at the reactor based positron source at FRM-II

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, C.; Kögel, G.; Repper, R.; Schreckenbach, K.; Sperr, P.; Straßer, B.; Triftshäuser, W.

    2002-05-01

    The principle of the in-pile positron source at the Munich research reactor FRM-II is based on absorption of high energy prompt γ-rays from thermal neutron capture in 113Cd. For this purpose, a cadmium cap is placed inside the tip of the inclined beam tube SR-11 in the moderator tank of the reactor, where an undisturbed thermal neutron flux up to 2×10 14n cm-2 s-1 is expected. Inside the cadmium cap a structure of platinum foils is placed for converting high energy γ-radiation into positron-electron pairs. Due to the negative positron work function, moderation in annealed platinum leads to emission of monoenergetic positrons. Therefore, platinum will also be used as moderator, since its moderation property seems to yield long-term stability under reactor conditions and it is much easier to handle than tungsten. Model calculations were performed with SIMION-7.0w to optimise geometry and potential of Pt-foils and electrical lenses. It could be shown that the potentials between the Pt-foils must be chosen in the range of 1-10 V to extract moderated positrons. After successive acceleration to 5 keV by four electrical lenses the beam is magnetically guided in a solenoid field of 7.5 mT resulting in a beam diameter of about 25 mm. An intensity of about 10 10 slow positrons per second is expected in the primary positron beam. Outside of the reactor shield a W(1 0 0) single crystal remoderation stage will lead to an improvement of the positron beam brilliance before the positrons are guided to the experimental facilities.

  7. Transverse single bunch instability study on BEPC

    NASA Astrophysics Data System (ADS)

    Gao, J.; Sun, Y. P.

    2007-04-01

    In recent years, a lot of experiments were done on ESRF and ELETTRA to study the single bunch transverse instability. To prevent such instabilities on BEPCII in the future, experiments were made on the single bunch transverse instability threshold current versus the chromaticity on BEPC. By analyzing the experimental data based on the theory developed in [J. Gao, Nucl. Instr. and Meth. A 416 (1998) 186 (see also PAC97, Vancouver, Canada, 1997, p. 1605).], the transverse loss factor of BEPC and the corresponding scaling law are obtained.

  8. Online beam energy measurement of Beijing electron positron collider II linear accelerator

    NASA Astrophysics Data System (ADS)

    Wang, S.; Iqbal, M.; Liu, R.; Chi, Y.

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  9. Beam induced vacuum measurement error in BEPC II

    NASA Astrophysics Data System (ADS)

    Huang, Tao; Xiao, Qiong; Peng, XiaoHua; Wang, HaiJing

    2011-12-01

    When the beam in BEPCII storage ring aborts suddenly, the measured pressure of cold cathode gauges and ion pumps will drop suddenly and decrease to the base pressure gradually. This shows that there is a beam induced positive error in the pressure measurement during beam operation. The error is the difference between measured and real pressures. Right after the beam aborts, the error will disappear immediately and the measured pressure will then be equal to real pressure. For one gauge, we can fit a non-linear pressure-time curve with its measured pressure data 20 seconds after a sudden beam abortion. From this negative exponential decay pumping-down curve, real pressure at the time when the beam starts aborting is extrapolated. With the data of several sudden beam abortions we have got the errors of that gauge in different beam currents and found that the error is directly proportional to the beam current, as expected. And a linear data-fitting gives the proportion coefficient of the equation, which we derived to evaluate the real pressure all the time when the beam with varied currents is on.

  10. Performance study of whole-body, multislice positron computed tomograph: POSITOLOGICA-II

    SciTech Connect

    Takami, K.; Murayama, H.; Nohara, N.; Okajima, K.; Tanaka, E.; Tomitani, T.; Veda, K.; Yamamoto, M.

    1983-02-01

    A 3-detector ring, 5-slice whole-body positron CT has been developed and is being tested. The PCT, POSITOLOGICA-II, has a total of 480 BGO's (160/ring), and employs continuous rotation scan (0.5rps). By using a 15mm wide BGO, a 9.2mm FWHM spatial resolution for reconstructed image is obtained at the center of FOV. Measured phantom diameter dependence of the true count rate shows good agreement with theoretically anticipated characteristics, including maximum sensitivity at around 30cm dia. Sensitivities for 20cm dia. phantom are 28 and 38 kcps/..mu..Ci/ml for in-plane and cross-plane, respectively, including scattered coincidences. Relative system detection efficiency measured with a line source at FOV center is 96% at 15ns time window (90% at 12ns), basing on 100% efficiency in 2024ns.

  11. The beam energy feedback system for Beijing electron positron collider II linac.

    PubMed

    Wang, S; Iqbal, M; Chi, Y; Liu, R; Huang, X

    2017-03-01

    A beam-energy feedback system has been developed for the injection linac to meet the beam quality needed for the Beijing electron positron collider II storage ring. This paper describes the implementation and commissioning of this system in detail. The system consists of an energy measurement unit, application software, and an actuator unit. A non-intersecting beam energy monitor was developed to allow real-time online energy adjustment. The beam energy adjustment is achieved by adjusting the output microwave phase of the RF power source station. The phase control mechanism has also been modified, and a new control method taking the return difference of the phase shifter into account is used to improve the system's performance. This system achieves the design aim and can adjust the beam center energy with a rate of 2 Hz. With the energy feedback system, the stability of the injection rate is better; the fluctuation range is reduced from 20 mA/min to 10 mA/min, while the stability of the beam center energy is maintained within ±0.1%.

  12. The electron-cloud instability in the arcs of the PEP-II positron ring

    SciTech Connect

    Furman, Miguel A.; Lambertson, Glen R.

    1998-03-01

    We have applied our simulation code ''POSINST'' to evaluate, in linear approximation, the contribution to the growth rate of the electron-cloud instability (ECI) from the pumping sections and the dipole bending magnets in the arcs of the PEP-II positron ring. A key ingredient in our model is a detailed description of the secondary emission process off the TiN-coated chambers. Another important element is the analytic computation of the electric field produced by the beam, including the effects from surface charges. Space-charge forces of the electron cloud upon itself are also included, although these forces are negligible under nominal conditions. Bunch-length effects are optionally included by slicing the bunch into several kicks. We conclude that the growth rate is dominated by the pumping sections and scales linearly with the photoelectric yield Y'. For Y' = 1, our present estimate is in the range {approx} 1000-1300 s{sup -1}, depending upon the value of the photon reflectivity R. This is in the range controllable by the transverse feedback system. The contributions to the growth rate from other magnets and from other sections of the ring remain to be evaluated.

  13. Evaluation of copper-labeled Cu(II) bis(thiosemicarbazone) complexes as blood flow tracers for positron emission tomography

    SciTech Connect

    Bott, A.J.

    1990-01-01

    Positron emmision tomography (PET) is an imaging technique not widely available for clinical diagnosis due to the costs of producing positron-emitting radiolabels. The development of radiotracers labeled with generator-produced positron emitters would facilitate the use of PET by eliminating the need for an in-house cyclotron. Copper-62 is a generator-produced positron emitter potentially useful for labeling PET radiopharmaceuticals. Copper-62 labeled Cu(II) pyruvaldehyde bis(N[sup 4]-methylthiosemicarbazone), Cu(PTSM), is a proposed PET perfusion tracer of the brain, heart, and kidneys. After IV injection in animals, copper-labeled Cu(PTSM) affords high initial uptake followed by prolonged retention of radiocopper in these organs. This retention is thought to be a result of reductive decomposition of the copper-labeled copper(II) complex by intracellular glutathione, GSH. To validate copper-62 labeled Cu(PTSM) as a myocardial and renal perfusion tracer, the regional radiocopper level afforded by intravenous copper-67 labeled Cu(PTSM) was compared to the absolute blood flow measured with labeled microspheres in normal dog kidneys and surgically infarcted myocardia. In the heart and randomly sectioned kidneys, an excellent correlation resulted. In kidneys dissected to separate anatomical regions, radiocopper levels increased montonically with increasing blood flows for individual dogs, but a linear correlation was observed when data from 12 animals was combined. Should the distribution of Cu(PTSM) vary with naturally occuring GSH fluctuations, the clinical utility of this radiotracer would be limited. Therefore, to validate further copper-62 labeled Cu(PTSM), the biodistribution of copper-67 labeled (PTSM) was determined in GSH-depleted rats. Relatively large GSH reductions in the experimental animals caused only slight changes in the distribution of Cu(PTSM). Another 23 copper-67 labeled compounds were tested.

  14. Study of PRIMAVERA steel samples by positron annihilation spectroscopy technique II - Lifetime measurements

    NASA Astrophysics Data System (ADS)

    Krsjak, V.; Grafutin, V.; Ilyukhina, O.; Burcl, R.; Ballesteros, A.; Hähner, P.

    2012-02-01

    In the present article, a positron annihilation lifetime technique was used for the study of VVER-440/230 weld materials, manufactured in the frame of the international PRIMAVERA project on microstructural investigation of the irradiated WWER-440 reactor pressure vessel steel. The present results complement our previous report of positron angular correlation experiments and provide in-depth characterization of vacancy type defects behavior under irradiation and thermal treatment. The results give new insight into the previously published atom probe tomography and angular correlation of annihilation radiation studies. The measurements do not show any association of phosphorus or its segregation to the open volume defects investigated by positron annihilation spectroscopy. The embrittlement effects related to the phosphorus seem to be effectively annealed-out during 475 °C thermal treatment and the post annealing microstructure and mechanical properties of the material are consequently affected mostly by agglomerations of vacancy clusters coarsened during thermal treatment.

  15. Infrared, Raman, 1H NMR, thermal and positron annihilation lifetime studies of Pb(II), Sn(II), Sb(III), Bi(III)-barbital complexes

    NASA Astrophysics Data System (ADS)

    Refat, Moamen S.; Sharshar, T.

    2012-05-01

    Metal complexes of Pb(II), Sn(II), Sb(III) and Bi(III) with a barbital sodium were synthesized and characterized by several techniques, including elemental analysis (C, H and N), molar conductance measurements, infrared, Raman, 1H NMR, positron annihilation lifetime and thermogravimetric analysis. Reactions of barbital sodium (NaL) with salts of Pb(NO3)2, SnCl2ṡ2H2O, SbCl3 and BiCl3 affords four novel mononuclear complexes [Pb(HL)2], [Sn(L)(H2O)], [Sb(HL)(L)] and [Bi(HL)(L)]. In complexes of Pb(II), Sb(III) and Bi(III), the molar ratio of metal-to-ligand is 1:2. Both of Sb(III) and Bi(III) complexes have six coordination via two molecules of barbital (HL and L), one of them deprotonated NH. The Pb(II) complex has a central metal ion adopts tetradentate fashion which surrounded by two (HL) barbital moieties. The elemental analysis shows that Sn(II) complex is tetradentate 1:1 ratio, chelated through oxygen sbnd O of (ONa), deprotonated (sbnd NH) and one coordinated water molecule. The positron annihilation lifetime parameters were found to be dependent on the structure, electronic configuration and molecular weight of metal complexes.

  16. Large-dimension configuration-interaction calculations of positron binding to the group-II atoms

    SciTech Connect

    Bromley, M. W. J.; Mitroy, J.

    2006-03-15

    The configuration-interaction (CI) method is applied to the calculation of the structures of a number of positron binding systems, including e{sup +}Be, e{sup +}Mg, e{sup +}Ca, and e{sup +}Sr. These calculations were carried out in orbital spaces containing about 200 electron and 200 positron orbitals up to l=12. Despite the very large dimensions, the binding energy and annihilation rate converge slowly with l, and the final values do contain an appreciable correction obtained by extrapolating the calculation to the l{yields}{infinity} limit. The binding energies were 0.00317 hartree for e{sup +}Be, 0.0170 hartree for e{sup +}Mg, 0.0189 hartree for e{sup +}Ca, and 0.0131 hartree for e{sup +}Sr.

  17. Spectroscopic, Elemental and Thermal Analysis, and Positron Annihilation Studies on Ca(II), Sr(II), Ba(II), Pb(II), and Fe(III) Penicillin G Potassium Complexes

    NASA Astrophysics Data System (ADS)

    Refat, M. S.; Sharshara, T.

    2015-11-01

    The [Pb(Pin)2] · 3H2O, [M(Pin)(H2O)2(Cl)] · nH2O (M = SrII, CaII or BaII; n = 0-1), and [Fe(Pin)2(Cl)(H2O)] · H2O penicillin G potassium (Pin) complexes were synthesized and characterized using elemental analyses, molar conductivity, thermal analysis and electronic spectroscopy techniques. The positron annihilation lifetime (PAL) and Doppler broadening (DB) techniques have been employed to probe the defects and structural changes of Pin ligand and its complexes. The PAL and DB line-shape parameters were discussed in terms of the structure, molecular weight, ligand-metal molar ratio, and other properties of the Pin complexes.

  18. Positron microscopy

    SciTech Connect

    Hulett, L.D. Jr.; Xu, J.

    1995-02-01

    The negative work function property that some materials have for positrons make possible the development of positron reemission microscopy (PRM). Because of the low energies with which the positrons are emitted, some unique applications, such as the imaging of defects, can be made. The history of the concept of PRM, and its present state of development will be reviewed. The potential of positron microprobe techniques will be discussed also.

  19. A search for supersymmetric electrons with the Mark II detector at PEP (Positron Electron Project)

    SciTech Connect

    LeClaire, B.W.

    1987-10-01

    An experimental search for selectrons, the supersymmetric partner of the electron, has been performed at the PEP storage ring at SLAC using the Mark II detector. The experimental search done was based upon hypothetical reaction in e/sup +/e/sup -/ interactions at PEP center of mass energies of 29 GeV. In this reaction the selectrons, e-tilde, are assumed produced by the interaction of one of initial state electrons with a photon radiated from the other initial state electron. This latter electron is assumed to continue down the beam pipe undetected. The photon and electron then produce a selectron and a photino, ..gamma..-tilde, in the supersymmetric analog of Compton scattering. The photino is assumed to be the lightest supersymmetric particle, and as such, does not interact in the detector, thereby escaping detection very much like a neutrino. The selectron is assumed to immediately decay into an electron and photino. This electron is produced with large p perpendicular with respect to the beam pipe, since it must balance the transverse momentum carried off by the photinos. Thus, the experimental signature of the process is a single electron in the detector with a large unbalanced tranverse momentum. No events of this type were observed in the original search of 123 pb/sup -1/ of data, resulting in a cross section limit of less than 2.4 x 10/sup -2/ pb (at the 95% CL) within the detector acceptance. This cross section upper limit applies to any process which produces anomalous single electron events with missing transverse momentum. When interpreted as a supersymmetry search it results in a lower selectron mass limit of 22.2 GeV/c/sup 2/ for the case of massless photinos. Limits for non-zero mass photinos have been calculated. 87 refs., 67 figs., 17 tabs.

  20. Positron follow-up in liquid water: II. Spatial and energetic study for the most important radioisotopes used in PET.

    PubMed

    Champion, C; Le Loirec, C

    2007-11-21

    With the increasing development of positron emission tomography (PET), beta(+)-emitters are more and more regularly used in nuclear medicine. Therefore, today it is of prime importance to have a reliable description of their behavior in living matter in order to quantify the full spectra of the molecular damages potentially radio-induced and then to access a cellular dosimetry. In this work, we present a detailed inter-comparison of the main isotopes commonly used in PET: (18)F, (11)C, (13)N, (15)O, (68)Ga and (82)Rb. We have used an event-by-event Monte Carlo code recently developed for positron tracking in water (Champion and Le Loirec 2006 Phys. Med. Biol. 51 1707-23) which consists in simulating step-by-step, interaction after interaction, the history of each ionizing particle created during the irradiation of the biological matter. This simulation has been finally adapted for describing the decays of medically important positron emitters. Quantitative information about positron penetrations, Positronium formation, annihilation event distributions, energy deposit patterns and dose profiles is then accessible and compared to published measurements and/or calculations.

  1. Positron Physics

    NASA Technical Reports Server (NTRS)

    Drachman, Richard J.

    2003-01-01

    I will give a review of the history of low-energy positron physics, experimental and theoretical, concentrating on the type of work pioneered by John Humberston and the positronics group at University College. This subject became a legitimate subfield of atomic physics under the enthusiastic direction of the late Sir Harrie Massey, and it attracted a diverse following throughout the world. At first purely theoretical, the subject has now expanded to include high brightness beams of low-energy positrons, positronium beams, and, lately, experiments involving anti-hydrogen atoms. The theory requires a certain type of persistence in its practitioners, as well as an eagerness to try new mathematical and numerical techniques. I will conclude with a short summary of some of the most interesting recent advances.

  2. Propagation and Generation of Electromagnetic Waves at Proton Gyrofrequencies in a Relativistic Electron-Positron Plasma. II. Excitation of Electromagnetic Waves

    NASA Astrophysics Data System (ADS)

    Zheleznyakov, V. V.; Bespalov, P. A.

    2016-04-01

    In part I of this work [1], we study the dispersion characteristics of low-frequency waves in a relativistic electron-positron plasma. In part II, we examine the electromagnetic wave instability in this plasma caused by an admixture of nonrelativistic protons with energy comparable with the energy of relativistic low-mass particles. The instability occurs in the frequency band between the fundamental harmonic of proton gyrofrequency and the fundamental harmonic of relativistic electron gyrofrequency. The results can be used for the interpretation of known observations of the pulsar emissions obtained with a high time and frequency resolution. The considered instability can probably be the initial stage of the microwave radio emission nanoshots typical of the pulsar in the Crab Nebula.

  3. Meson spectroscopy viewed from J//PSI/ decay: Gluonic states at BEPC

    SciTech Connect

    Chanowitz, M.S.

    1987-07-01

    The theoretical and experimental status of the search for gluonic states is reviewed. Progress clearly requires much higher statistics studies of J//psi/ decay, as will be possible at the Beijing Electron Positron Collider. 83 refs.

  4. Noninvasive positron emission tomography imaging of cell death using a novel small-molecule probe, (18)F labeled bis(zinc(II)-dipicolylamine) complex.

    PubMed

    Wang, Hongliang; Tang, Xiaolan; Tang, Ganghua; Huang, Tingting; Liang, Xiang; Hu, Kongzhen; Deng, Huaifu; Yi, Chang; Shi, Xinchong; Wu, Kening

    2013-08-01

    The synthetic bis(zinc(II)-dipicolylamine) (DPAZn2) coordination complexes are known to have a high specific and selective affinity to target the exposed phosphatidylserine (PS) on the surface of dead and dying cells. An (18)F-labeled DPAZn2 complex (4-(18)F-Fluoro-benzoyl-bis(zinc(II)-dipicolylamine), (18)F-FB-DPAZn2) as positron emission tomography (PET) tracer was developed and evaluated for in vivo imaging of tumor treated with a chemical agent. The in vitro cell stain studies revealed that fluorescent DPAZn2 complexes (Dansyl-DPAZn2) stained the same cells (apoptotic and necrotic cells) as fluorescein isothiocyanate (FITC) labeled Annexin V (FITC-Annexin V). The radiosynthesis of (18)F-FB-DPAZn2 was achieved through the amidation the precursor bis(2,2'-dipicolylamine) derivative (DPA2) with the prosthetic group N-succinimidyl-4-[(18)F]-fluorobenzoate ((18)F-SFB) and chelation with zinc nitrate. In the biodistribution study, the fast clearance of (18)F-FB-DPAZn2 from blood and kidney was observed and high uptake in liver and intestine within 90 min postinjection was also found. For the PET imaging, significantly higher tumor uptake of (18)F-FB-DPAZn2 was observed in the adriamycin (ADM)-treated Hepa1-6 hepatocellular carcinoma-bearing mice than that in the untreated tumor-model mice, while a slightly decreased tumor uptake of (18)F-FDG was found in the ADM-treated tumor-bearing mice. The results indicate that (18)F-FB-DPAZn2 has the similar capability of apoptosis detection as FITC-Annexin V and seems to be a potential PET tracer for noninvasive evaluation and monitoring of anti-tumor chemotherapy. The high uptake of (18)F-FB-DPAZn2 in the abdomen needs to optimize the structure for improving its pharmacokinetics characteristics in the future work.

  5. Impact of 18F-Fluoro-2-Deoxyglucose Positron Emission Tomography on Treatment Strategy and Radiotherapy Planning for Stage I-II Hodgkin Disease: A Prospective Multicenter Study

    SciTech Connect

    Pommier, Pascal; Dussart, Sophie; Girinsky, Theodore; Chabaud, Sylvie; Lagrange, Jean Leon; Nguyen, Tan Dat; Beckendorff, Veronique; D'Hombres, Anne; Artignan, Xavier; Bondiau, Pierre Yves; Carrie, Christian; Giammarile, Francesco

    2011-03-01

    Purpose: To quantify the impact of preradiotherapy 18F-fluoro-2-deoxyglucose positron-emission tomography (FDG-PET) on treatment strategy and radiotherapy planning for patients with Stage I/II Hodgkin disease included in a large prospective multicenter study. Patients and Methods: Conventional computed tomography and FDG-PET were performed just before the planned radiotherapy. The radiotherapy plan was first elaborated under blinded conditions for FDG-PET data. Then, the medical staff was asked to confirm or not confirm the treatment strategy and, if appropriate, to modify the radiotherapy plan based on additional information from FDG-PET. Results: Between January 2004 and January 2006, 137 patients were included (124 were available for analysis) in 11 centers (108 adults, 16 children). All but 1 patient had received chemotherapy before inclusion. Prechemotherapy work-up included FDG-PET for 61 patients, and data were available for elaboration of the first radiotherapy plan. Based on preradiotherapy FDG-PET data, the radiotherapy was cancelled in 6 patients (4.8%), and treatment plan modifications occurred in 16 patients (12.9%): total dose (11 patients), CTV volume (5 patients), number of beam incidences (6 patients), and number of CTV (6 patients). The concordance between the treatment strategies with or without preradiotherapy FDG-PET was 82.3%. Concordance results were not significantly different when prechemotherapy PET-CT information was available. Conclusion: Preradiotherapy FDG-PET for treatment planning in Hodgkin lymphoma may lead to significant modification of the treatment strategy and the radiotherapy planning in patients with Stage I or II Hodgkin disease, even in those who have undergone FDG-PET as part of the prechemotherapy work-up.

  6. Early Positron Emission Tomography Response-Adapted Treatment in Stage I and II Hodgkin Lymphoma: Final Results of the Randomized EORTC/LYSA/FIL H10 Trial.

    PubMed

    André, Marc P E; Girinsky, Théodore; Federico, Massimo; Reman, Oumédaly; Fortpied, Catherine; Gotti, Manuel; Casasnovas, Olivier; Brice, Pauline; van der Maazen, Richard; Re, Alessandro; Edeline, Véronique; Fermé, Christophe; van Imhoff, Gustaaf; Merli, Francesco; Bouabdallah, Réda; Sebban, Catherine; Specht, Lena; Stamatoullas, Aspasia; Delarue, Richard; Fiaccadori, Valeria; Bellei, Monica; Raveloarivahy, Tiana; Versari, Annibale; Hutchings, Martin; Meignan, Michel; Raemaekers, John

    2017-03-14

    Purpose Patients who receive combined modality treatment for stage I and II Hodgkin lymphoma (HL) have an excellent outcome. Early response evaluation with positron emission tomography (PET) scan may improve selection of patients who need reduced or more intensive treatments. Methods We performed a randomized trial to evaluate treatment adaptation on the basis of early PET (ePET) after two cycles of doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) in previously untreated-according to European Organisation for Research and Treatment of Cancer criteria favorable (F) and unfavorable (U)-stage I and II HL. The standard arm consisted of ABVD followed by involved-node radiotherapy (INRT), regardless of ePET result. In the experimental arm, ePET-negative patients received ABVD only (noninferiority design), whereas ePET-positive patients switched to two cycles of bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone (BEACOPPesc) and INRT (superiority design). Primary end point was progression-free survival (PFS). Results Of 1,950 randomly assigned patients, 1,925 received an ePET-361 patients (18.8%) were positive. In ePET-positive patients, 5-year PFS improved from 77.4% for standard ABVD + INRT to 90.6% for intensification to BEACOPPesc + INRT (hazard ratio [HR], 0.42; 95% CI, 0.23 to 0.74; P = .002). In ePET-negative patients, 5-year PFS rates in the F group were 99.0% versus 87.1% (HR, 15.8; 95% CI, 3.8 to 66.1) in favor of ABVD + INRT; the U group, 92.1% versus 89.6% (HR, 1.45; 95% CI, 0.8 to 2.5) in favor of ABVD + INRT. For both F and U groups, noninferiority of ABVD only compared with combined modality treatment could not be demonstrated. Conclusion In stage I and II HL, PET response after two cycles of ABVD allows for early treatment adaptation. When ePET is positive after two cycles of ABVD, switching to BEACOPPesc + INRT significantly improved 5-year PFS. In ePET-negative patients, noninferiority of ABVD only

  7. First platinum moderated positron beam based on neutron capture

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, C.; Kögel, G.; Repper, R.; Schreckenbach, K.; Sperr, P.; Triftshäuser, W.

    2002-12-01

    A positron beam based on absorption of high energy prompt γ-rays from thermal neutron capture in 113Cd was installed at a neutron guide of the high flux reactor at the ILL in Grenoble. Measurements were performed for various source geometries, dependent on converter mass, moderator surface and extraction voltages. The results lead to an optimised design of the in-pile positron source which will be implemented at the Munich research reactor FRM-II. The positron source consists of platinum foils acting as γ-e +e --converter and positron moderator. Due to the negative positron work function moderation in heated platinum leads to emission of monoenergetic positrons. The positron work function of polycrystalline platinum was determined to 1.95(5) eV. After acceleration to several keV by four electrical lenses the beam was magnetically guided in a solenoid field of 7.5 mT leading to a NaI-detector in order to detect the 511 keV γ-radiation of the annihilating positrons. The positron beam with a diameter of less than 20 mm yielded an intensity of 3.1×10 4 moderated positrons per second. The total moderation efficiency of the positron source was about ɛ=1.06(16)×10 -4. Within the first 20 h of operation a degradation of the moderation efficiency of 30% was observed. An annealing procedure at 873 K in air recovers the platinum moderator.

  8. Positron-rubidium scattering

    NASA Technical Reports Server (NTRS)

    Mceachran, R. P.; Horbatsch, M.; Stauffer, A. D.

    1990-01-01

    A 5-state close-coupling calculation (5s-5p-4d-6s-6p) was carried out for positron-Rb scattering in the energy range 3.7 to 28.0 eV. In contrast to the results of similar close-coupling calculations for positron-Na and positron-K scattering the (effective) total integrated cross section has an energy dependence which is contrary to recent experimental measurements.

  9. Positron microprobe at LLNL

    SciTech Connect

    Asoka, P; Howell, R; Stoeffl, W

    1998-11-01

    The electron linac based positron source at Lawrence Livermore National Laboratory (LLNL) provides the world's highest current beam of keV positrons. We are building a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with sub-micron resolution. The widely spaced and intense positron packets from the tungsten moderator at the end of the 100 MeV LLNL linac are captured and trapped in a magnetic bottle. The positrons are then released in 1 ns bunches at a 20 MHz repetition rate. With a three-stage re-moderation we will compress the cm-sized original beam to a 1 micro-meter diameter final spot on the target. The buncher will compress the arrival time of positrons on the target to less than 100 ps. A detector array with up to 60 BaF2 crystals in paired coincidence will measure the annihilation radiation with high efficiency and low background. The energy of the positrons can be varied from less than 1 keV up to 50 keV.

  10. Positrons in surface physics

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, Christoph

    2016-12-01

    Within the last decade powerful methods have been developed to study surfaces using bright low-energy positron beams. These novel analysis tools exploit the unique properties of positron interaction with surfaces, which comprise the absence of exchange interaction, repulsive crystal potential and positron trapping in delocalized surface states at low energies. By applying reflection high-energy positron diffraction (RHEPD) one can benefit from the phenomenon of total reflection below a critical angle that is not present in electron surface diffraction. Therefore, RHEPD allows the determination of the atom positions of (reconstructed) surfaces with outstanding accuracy. The main advantages of positron annihilation induced Auger-electron spectroscopy (PAES) are the missing secondary electron background in the energy region of Auger-transitions and its topmost layer sensitivity for elemental analysis. In order to enable the investigation of the electron polarization at surfaces low-energy spin-polarized positrons are used to probe the outermost electrons of the surface. Furthermore, in fundamental research the preparation of well defined surfaces tailored for the production of bound leptonic systems plays an outstanding role. In this report, it is envisaged to cover both the fundamental aspects of positron surface interaction and the present status of surface studies using modern positron beam techniques.

  11. The application of positron emission tomography (PET/CT) in diagnosis of breast cancer. Part II. Diagnosis after treatment initiation, future perspectives

    PubMed Central

    Jodłowska, Elżbieta; Czarnywojtek, Agata; Rewers, Amanda; Jarząbek, Grażyna; Kędzia, Witold; Ruchała, Marek

    2016-01-01

    Similarly to the applications described in the first part of this publication, positron emission tomography with computed tomography (PET/CT) is also gaining importance in monitoring a tumour's response to therapy and diagnosing breast cancer recurrences. This is additionally caused by the fact that many new techniques (dual-time point imaging, positron emission tomography with magnetic resonance PET/MR, PET/CT mammography) and radiotracers (16α-18F-fluoro-17β-estradiol, 18F-fluorothymidine) are under investigation. The highest sensitivity and specificity when monitoring response to treatment is achieved when the PET/CT scan is made after one or two chemotherapy courses. Response to anti-hormonal treatment can also be monitored, also when new radiotracers, such as FES, are used. When monitoring breast cancer recurrences during follow-up, PET/CT has higher sensitivity than conventional imaging modalities, making it possible to monitor the whole body simultaneously. New techniques and radiotracers enhance the sensitivity and specificity of PET and this is why, despite relatively high costs, it might become more widespread in monitoring response to treatment and breast cancer recurrences. PMID:27647983

  12. Positrons for linear colliders

    SciTech Connect

    Ecklund, S.

    1987-11-01

    The requirements of a positron source for a linear collider are briefly reviewed, followed by methods of positron production and production of photons by electromagnetic cascade showers. Cross sections for the electromagnetic cascade shower processes of positron-electron pair production and Compton scattering are compared. A program used for Monte Carlo analysis of electromagnetic cascades is briefly discussed, and positron distributions obtained from several runs of the program are discussed. Photons from synchrotron radiation and from channeling are also mentioned briefly, as well as positron collection, transverse focusing techniques, and longitudinal capture. Computer ray tracing is then briefly discussed, followed by space-charge effects and thermal heating and stress due to showers. (LEW)

  13. Positron diffusion in Si

    SciTech Connect

    Nielsen, B.; Lynn, K.G.; Vehanen, A.; Schultz, P.J.

    1985-06-01

    Positron diffusion in Si(100) and Si(111) has been studied using a variable energy positron beam. The positron diffusion coefficient is found to be D/sub +/ = 2.7 +- 0.3 cm/sup 2//sec using a Makhov-type positron implantation profile, which is demonstrated to fit the data more reliably than the more commonly applied exponential profile. The diffusion related parameter, E/sub 0/, which results from the exponential profile, is found to be 4.2 +- 0.2 keV, significantly longer than previously reported values. A drastic reduction in E/sub 0/ is found after annealing the sample at 1300 K, showing that previously reported low values of E/sub 0/ are probably associated with the thermal history of the sample.

  14. Alternative positron-target design for electron-positron colliders

    SciTech Connect

    Donahue, R.J. ); Nelson, W.R. )

    1991-04-01

    Current electron-positron linear colliders are limited in luminosity by the number of positrons which can be generated from targets presently used. This paper examines the possibility of using an alternate wire-target geometry for the production of positrons via an electron-induced electromagnetic cascade shower. 39 refs., 38 figs., 5 tabs.

  15. Positron sources for Linear Colliders

    SciTech Connect

    Gai Wei; Liu Wanming

    2009-09-02

    Positron beams have many applications and there are many different concepts for positron sources. In this paper, only positron source techniques for linear colliders are covered. In order to achieve high luminosity, a linear collider positron source should have a high beam current, high beam energy, small emittance and, for some applications, a high degree of beam polarization. There are several different schemes presently being developed around the globe. Both the differences between these schemes and their common technical challenges are discussed.

  16. Early evaluation of tumour metabolic response using [18F]fluorodeoxyglucose and positron emission tomography:a pilot study following the phase II chemotherapy schedule for temozolomide in recurrent high-grade gliomas

    PubMed Central

    Brock, C S; Young, H; O'Reilly, S M; Matthews, J; Osman, S; Evans, H; Newlands, E S; Price, P M

    2000-01-01

    Quantitation of metabolic changes in tumours may provide an objective measure of clinical and subclinical response to anticancer therapy. This pilot study assesses the value of quantitation of metabolic rate of glucose (MRGlu) measured in mmol min−1ml−1to assess early subclinical response to therapy in a relatively non-responsive tumour. Nine patients receiving the CRC Phase II study schedule of temozolomide were assessed with [18F]fluorodeoxyglucose ([18F]FDG) dynamic positron emission tomography (PET) scans prior to and 14 days after treatment with temozolomide given as 750–1000 mg m−2over 5 days every 28 days. Tumour MRGlu was calculated and compared with objective response at 8 weeks. Pretreatment MRGlu was higher in responders than non-responders. The responding patient group had a greater than 25% reduction in MRGlu in regions of high focal tumour uptake (HFU). Whole tumour changes in MRGlu did not correlate with response. Percentage change in HFU standardized uptake value (SUV) did discriminate the responding from the non-responding patients, but not as well as with MRGlu. Large differences also occurred in the normal brain SUV following treatment. Thus, MRGlu appeared to be a more sensitive discriminator of response than the simplified static SUV analysis. Changes in MRGlu may reflect the degree of cell kill following chemotherapy and so may provide an objective, quantitative subclinical measure of response to therapy. © 2000 Cancer Research Campaign PMID:10682673

  17. Positron studies of defected metals, metallic surfaces

    SciTech Connect

    Bansil, A.

    1991-01-01

    Specific problems proposed under this project included the treatment of electronic structure and momentum density in various disordered and defected systems. Since 1987, when the new high-temperature superconductors were discovered, the project focused extensively on questions concerning the electronic structure and Fermiology of high-[Tc] superconductors, in particular, (i) momentum density and positron experiments, (ii) angle-resolved photoemission intensities, (iii) effects of disorder and substitutions in the high-[Tc]'s.

  18. Positron annihilation processes update

    NASA Technical Reports Server (NTRS)

    Guessoum, Nidhal; Skibo, Jeffrey G.; Ramaty, Reuven

    1997-01-01

    The present knowledge concerning the positron annihilation processes is reviewed, with emphasis on the data of the cross sections of the various processes of interest in astrophysical applications. Recent results are presented including results on reaction rates and line widths, the validity of which is verified.

  19. Positron excitation of neon

    NASA Technical Reports Server (NTRS)

    Parcell, L. A.; Mceachran, R. P.; Stauffer, A. D.

    1990-01-01

    The differential and total cross section for the excitation of the 3s1P10 and 3p1P1 states of neon by positron impact were calculated using a distorted-wave approximation. The results agree well with experimental conclusions.

  20. The Japanese Positron Factory

    NASA Astrophysics Data System (ADS)

    Okada, S.; Sunaga, H.; Kaneko, H.; Takizawa, H.; Kawasuso, A.; Yotsumoto, K.; Tanaka, R.

    1999-06-01

    The Positron Factory has been planned at Japan Atomic Energy Research Institute (JAERI). The factory is expected to produce linac-based monoenergetic positron beams having world-highest intensities of more than 1010e+/sec, which will be applied for R&D of materials science, biotechnology and basic physics & chemistry. In this article, results of the design studies are demonstrated for the following essential components of the facilities: 1) Conceptual design of a high-power electron linac with 100 MeV in beam energy and 100 kW in averaged beam power, 2) Performance tests of the RF window in the high-power klystron and of the electron beam window, 3) Development of a self-driven rotating electron-to-positron converter and the performance tests, 4) Proposal of multi-channel beam generation system for monoenergetic positrons, with a series of moderator assemblies based on a newly developed Monte Carlo simulation and the demonstrative experiment, 5) Proposal of highly efficient moderator structures, 6) Conceptual design of a local shield to suppress the surrounding radiation and activation levels.

  1. High current pulsed positron microprobe

    SciTech Connect

    Howell, R.H.; Stoeffl, W.; Kumar, A.; Sterne, P.A.; Cowan, T.E.; Hartley, J.

    1997-05-01

    We are developing a low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy to provide a new defect analysis capability at the 10{sup 10} e{sup +}s{sup -l} beam at the Lawrence Livermore National Laboratory electron linac. When completed, the pulsed positron microprobe will enable defect specific, 3-dimensional maps of defect concentrations with sub-micron resolution of defect location. By coupling these data with first principles calculations of defect specific positron lifetimes and positron implantation profiles we will both map the identity and concentration of defect distributions.

  2. Brucella ovis PA mutants for outer membrane proteins Omp10, Omp19, SP41, and BepC are not altered in their virulence and outer membrane properties.

    PubMed

    Sidhu-Muñoz, Rebeca S; Sancho, Pilar; Vizcaíno, Nieves

    2016-04-15

    Mutants in several genes have been obtained on the genetic background of virulent rough (lacking O-polysaccharide) Brucella ovis PA. The target genes encode outer membrane proteins previously associated with the virulence of smooth (bearing O-polysaccharide chains in the lipopolysaccharide) Brucella strains. Multiple attempts to delete omp16, coding for a homologue to peptidoglycan-associated lipoproteins, were unsuccessful, which suggests that Omp16 is probably essential for in vitro survival of B. ovis PA. Single deletion of omp10 or omp19-that encode two other outer membrane lipoproteins--was achieved, but the simultaneous removal of both genes failed, suggesting an essential complementary function between both proteins. Two other deletion mutants, defective in the Tol-C-homologue BepC or in the SP41 adhesin, were also obtained. Surprisingly when compared to previous results obtained with smooth Brucella, none of the B. ovis mutants showed attenuation in the virulence, either in the mouse model or in cellular models of professional and non-professional phagocytes. Additionally, and in contrast to the observations reported with smooth Brucella strains, several properties related to the outer membrane remained almost unaltered. These results evidence new distinctive traits between naturally rough B. ovis and smooth brucellae.

  3. Generation of monoenergetic positrons

    SciTech Connect

    Hulett, L.D. Jr.; Dale, J.M.; Miller, P.D. Jr.; Moak, C.D.; Pendyala, S.; Triftshaeuser, W.; Howell, R.H.; Alvarez, R.A.

    1983-01-01

    Many experiments have been performed in the generation and application of monoenergetic positron beams using annealed tungsten moderators and fast sources of /sup 58/Co, /sup 22/Na, /sup 11/C, and LINAC bremstrahlung. This paper will compare the degrees of success from our various approaches. Moderators made from both single crystal and polycrystal tungsten have been tried. Efforts to grow thin films of tungsten to be used as transmission moderators and brightness enhancement devices are in progress.

  4. Positron lifetime spectrometer using a DC positron beam

    DOEpatents

    Xu, Jun; Moxom, Jeremy

    2003-10-21

    An entrance grid is positioned in the incident beam path of a DC beam positron lifetime spectrometer. The electrical potential difference between the sample and the entrance grid provides simultaneous acceleration of both the primary positrons and the secondary electrons. The result is a reduction in the time spread induced by the energy distribution of the secondary electrons. In addition, the sample, sample holder, entrance grid, and entrance face of the multichannel plate electron detector assembly are made parallel to each other, and are arranged at a tilt angle to the axis of the positron beam to effectively separate the path of the secondary electrons from the path of the incident positrons.

  5. Positron moderation and detection for positronic atoms

    NASA Astrophysics Data System (ADS)

    Fardad, Abolfazl

    An apparatus is under development for H--+* production, atoms consisting of a positron bound in a Rydberg state to an H-- ion. High energy e+ from radioactive N2211a are slowed (moderated) to eV energies in solid neon and captured in a Penning trap. The procedure to deposit the neon is optimized, resulting in a 1.5% efficiency for moderating high energy e +. Neutral H--+* atoms with ˜100 eV will be produced from these trapped e+ and exit the trap, hitting a metal surface where the e+ annihilates. Back-to-back annihilation gamma photons (Egamma ≈ 0.511 MeV) detected in coincidence, at the expected energy are the fingerprint for H--+* production. A N2211a test source mocks H--+* experiments with ˜2.7% of the e+ emitting disintegrations detected. This high efficiency, with a background rate of ˜2.8 events/hour is achieved by surrounding the detectors with lead and cosmic ray detectors.

  6. Positron Annihilation in Insulating Materials

    SciTech Connect

    Asoka-Kumar, P; Sterne, PA

    2002-10-18

    We describe positron results from a wide range of insulating materials. We have completed positron experiments on a range of zeolite-y samples, KDP crystals, alkali halides and laser damaged SiO{sub 2}. Present theoretical understanding of positron behavior in insulators is incomplete and our combined theoretical and experimental approach is aimed at developing a predictive understanding of positrons and positronium annihilation characteristics in insulators. Results from alkali halides and alkaline-earth halides show that positrons annihilate with only the halide ions, with no apparent contribution from the alkali or alkaline-earth cations. This contradicts the results of our existing theory for metals, which predicts roughly equal annihilation contributions from cation and anion. We also present result obtained using Munich positron microprobe on laser damaged SiO{sub 2} samples.

  7. Positron Emission Tomography (PET)

    DOE R&D Accomplishments Database

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  8. Quantum positron acoustic waves

    SciTech Connect

    Metref, Hassina; Tribeche, Mouloud

    2014-12-15

    Nonlinear quantum positron-acoustic (QPA) waves are investigated for the first time, within the theoretical framework of the quantum hydrodynamic model. In the small but finite amplitude limit, both deformed Korteweg-de Vries and generalized Korteweg-de Vries equations governing, respectively, the dynamics of QPA solitary waves and double-layers are derived. Moreover, a full finite amplitude analysis is undertaken, and a numerical integration of the obtained highly nonlinear equations is carried out. The results complement our previously published results on this problem.

  9. Positron Emission Tomography (PET)

    SciTech Connect

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  10. Cyclotrons and positron emitting radiopharmaceuticals

    SciTech Connect

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  11. Portable Positron Measurement System (PPMS)

    SciTech Connect

    2011-01-01

    Portable Positron Measurement System (PPMS) is an automated, non-destructive inspection system based on positron annihilation, which characterizes a material's in situatomic-level properties during the manufacturing processes of formation, solidification, and heat treatment. Simultaneous manufacturing and quality monitoring now are possible. Learn more about the lab's project on our facebook site http://www.facebook.com/idahonationallaboratory.

  12. Portable Positron Measurement System (PPMS)

    ScienceCinema

    None

    2016-07-12

    Portable Positron Measurement System (PPMS) is an automated, non-destructive inspection system based on positron annihilation, which characterizes a material's in situatomic-level properties during the manufacturing processes of formation, solidification, and heat treatment. Simultaneous manufacturing and quality monitoring now are possible. Learn more about the lab's project on our facebook site http://www.facebook.com/idahonationallaboratory.

  13. Undulator Production of Polarized Positrons

    SciTech Connect

    William M. Bugg

    2008-08-27

    E-166 at SLAC has demonstrated the feasibilty of production of polarized positrons for the International Linear Collider using a helical undulator to produce polarized photons which are converted in a thin target to polarized positrons. The success of the experim ent has resulted in the choice of this technique for the baseline design of ILC.

  14. Positron Survival in Type II Supernovae

    DTIC Science & Technology

    1989-05-01

    56Co (daughter of 56Ni) or 4Ti. He predicted that both of these nuclei should be produced during explosive nucleosynthesis . The production of this...turned to cobalt at times of interest to us. I have therefore assumed that 56Co was the explosive nucleosynthesis product. The half-life of 56Co is 78.8...sixth edition, John Wiley and Sons, Inc., 1967, p. 189. Nomoto, K., et al. , "SN 1987A: Progenitor, Nucleosynthesis and Light Curves", 1988, preprint

  15. Positron emission mammography imaging

    SciTech Connect

    Moses, William W.

    2003-10-02

    This paper examines current trends in Positron Emission Mammography (PEM) instrumentation and the performance tradeoffs inherent in them. The most common geometry is a pair of parallel planes of detector modules. They subtend a larger solid angle around the breast than conventional PET cameras, and so have both higher efficiency and lower cost. Extensions to this geometry include encircling the breast, measuring the depth of interaction (DOI), and dual-modality imaging (PEM and x-ray mammography, as well as PEM and x-ray guided biopsy). The ultimate utility of PEM may not be decided by instrument performance, but by biological and medical factors, such as the patient to patient variation in radiotracer uptake or the as yet undetermined role of PEM in breast cancer diagnosis and treatment.

  16. Intense source of slow positrons

    NASA Astrophysics Data System (ADS)

    Perez, P.; Rosowsky, A.

    2004-10-01

    We describe a novel design for an intense source of slow positrons based on pair production with a beam of electrons from a 10 MeV accelerator hitting a thin target at a low incidence angle. The positrons are collected with a set of coils adapted to the large production angle. The collection system is designed to inject the positrons into a Greaves-Surko trap (Phys. Rev. A 46 (1992) 5696). Such a source could be the basis for a series of experiments in fundamental and applied research and would also be a prototype source for industrial applications, which concern the field of defect characterization in the nanometer scale.

  17. Cosmic Ray Positrons from Pulsars

    NASA Technical Reports Server (NTRS)

    Harding, Alice K.

    2010-01-01

    Pulsars are potential Galactic sources of positrons through pair cascades in their magnetospheres. There are, however, many uncertainties in establishing their contribution to the local primary positron flux. Among these are the local density of pulsars, the cascade pair multiplicities that determine the injection rate of positrons from the pulsar, the acceleration of the injected particles by the pulsar wind termination shock, their rate of escape from the pulsar wind nebula, and their propagation through the interstellar medium. I will discuss these issues in the context of what we are learning from the new Fermi pulsar detections and discoveries.

  18. Positron annihilation spectroscopy with magnetically analyzed beams

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Holt, W. H.; Mock, W., Jr.

    1982-01-01

    Lifetime measurements with magnetically analyzed positron beams were made in condensed media with uniform and non-uniform properties. As expected, the lifetime values with magnetically analyzed positron beams in uniform targets are similar to those obtained with conventional positron sources. The lifetime values with magnetically analyzed beams in targets which have non-uniform properties vary with positron energy and are different from the conventional positron source derived lifetime values in these targets.

  19. Resolvability of positron decay channels

    SciTech Connect

    Fluss, M.J.; Howell, R.H.; Rosenberg, I.J.; Meyer, P.

    1985-03-07

    Many data analysis treatments of positron experiments attempt to resolve two or more positron decay or exist channels which may be open simultaneously. Examples of the need to employ such treatments of the experimental results can be found in the resolution of the constituents of a defect ensemble, or in the analysis of the complex spectra which arise from the interaction of slow positrons at or near the surfaces of solids. Experimental one- and two-dimensional angular correlation of annihilation radiation experiments in Al single crystals have shown that two defect species (mono- and divacancies) can be resolved under suitable conditions. Recent experiments at LLNL indicate that there are a variety of complex exit channels open to positrons interacting at surfaces, and ultimely these decay channels must also be suitably resolved from one another. 6 refs., 4 figs.

  20. Positron trapping at grain boundaries

    SciTech Connect

    Dupasquier, A. ); Romero, R.; Somoza, A. )

    1993-10-01

    The standard positron trapping model has often been applied, as a simple approximation, to the interpretation of positron lifetime spectra in situations of diffusion-controlled trapping. This paper shows that this approximation is not sufficiently accurate, and presents a model based on the correct solution of the diffusion equation, in the version appropriate for studying positron trapping at grain boundaries. The model is used for the analysis of new experimental data on positron lifetime spectra in a fine-grained Al-Ca-Zn alloy. Previous results on similar systems are also discussed and reinterpreted. The analysis yields effective diffusion coefficients not far from the values known for the base metals of the alloys.

  1. High Power Polarized Positron Source

    NASA Astrophysics Data System (ADS)

    Mikhailichenko, Alexander

    2009-09-01

    We discuss the basics of polarized positron production by low energy polarized electrons. Efficiency of conversion ˜0.1-1% might be interesting for the Continuous Electron Beam Accelerator Facility (CEBAF) and the International Linear Collider (ILC).

  2. Photon correlations in positron annihilation

    SciTech Connect

    Gauthier, Isabelle; Hawton, Margaret

    2010-06-15

    The two-photon positron annihilation density matrix is found to separate into a diagonal center-of-energy factor implying maximally entangled momenta, and a relative factor describing decay. For unknown positron injection time, the distribution of the difference in photon arrival times is a double exponential at the para-Ps decay rate, consistent with experiment [V. D. Irby, Meas. Sci. Technol. 15, 1799 (2004)].

  3. SYNCHROTRON RADIATION, FREE ELECTRON LASER, APPLICATION OF NUCLEAR TECHNOLOGY, ETC.: Measurement of radiation dose at the north interaction point of BEPC II

    NASA Astrophysics Data System (ADS)

    Mo, Xiao-Hu; Zhang, Jian-Yong; Zhang, Tian-Bao; Zhang, Qing-Jiang; Achasov, Mikhail; Fu, Cheng-Dong; Muchnoi, Nikolay; Qin, Qing; Qu, Hua-Min; Wang, Yi-Fang; Wu, Jing-Min; Xu, Jin-Qiang; Yu, Bo-Xiang

    2009-10-01

    The technique details for measuring radiation dose are expounded. The results of gamma and neutron radiation levels are presented and the corresponding radiation shielding is discussed based on the simplified estimation. In addition, the photon radiation level move as background for future experiments is measured by a NaI(Tl) detector.

  4. Modelling Positron Interactions with Matter

    NASA Astrophysics Data System (ADS)

    Garcia, G.; Petrovic, Z.; White, R.; Buckman, S.

    2011-05-01

    In this work we link fundamental measurements of positron interactions with biomolecules, with the development of computer codes for positron transport and track structure calculations. We model positron transport in a medium from a knowledge of the fundamental scattering cross section for the atoms and molecules comprising the medium, combined with a transport analysis based on statistical mechanics and Monte-Carlo techniques. The accurate knowledge of the scattering is most important at low energies, a few tens of electron volts or less. The ultimate goal of this work is to do this in soft condensed matter, with a view to ultimately developing a dosimetry model for Positron Emission Tomography (PET). The high-energy positrons first emitted by a radionuclide in PET may well be described by standard formulas for energy loss of charged particles in matter, but it is incorrect to extrapolate these formulas to low energies. Likewise, using electron cross-sections to model positron transport at these low energies has been shown to be in serious error due to the effects of positronium formation. Work was supported by the Australian Research Council, the Serbian Government, and the Ministerio de Ciencia e Innovación, Spain.

  5. Method for photon activation positron annihilation analysis

    DOEpatents

    Akers, Douglas W.

    2006-06-06

    A non-destructive testing method comprises providing a specimen having at least one positron emitter therein; determining a threshold energy for activating the positron emitter; and determining whether a half-life of the positron emitter is less than a selected half-life. If the half-life of the positron emitter is greater than or equal to the selected half-life, then activating the positron emitter by bombarding the specimen with photons having energies greater than the threshold energy and detecting gamma rays produced by annihilation of positrons in the specimen. If the half-life of the positron emitter is less then the selected half-life, then alternately activating the positron emitter by bombarding the specimen with photons having energies greater then the threshold energy and detecting gamma rays produced by positron annihilation within the specimen.

  6. Performance of the (n,{gamma})-Based Positron Beam Facility NEPOMUC

    SciTech Connect

    Schreckenbach, K.; Hugenschmidt, C.; Piochacz, C.; Stadlbauer, M.; Loewe, B.; Maier, J.; Pikart, P.

    2009-01-28

    The in-pile positron source of NEPOMUC at the neutron source Heinz Maier-Leibnitz (FRM II) provides at the experimental site an intense beam of monoenergetic positrons with selectable energy between 15 eV and 3 keV. The principle of the source is based on neutron capture gamma rays produced by cadmium in a beam tube tip close to the reactor core. The gamma ray absorption in platinum produces positrons which are moderated and formed to the beam. An unprecedented beam intensity of 9.10{sup 8} e{sup +}/s is achieved (1 keV). The performance and applications of the facility are presented.

  7. Positron spectroscopy for materials characterization

    SciTech Connect

    Schultz, P.J.; Snead, C.L. Jr.

    1988-01-01

    One of the more active areas of research on materials involves the observation and characterization of defects. The discovery of positron localization in vacancy-type defects in solids in the 1960's initiated a vast number of experimental and theoretical investigations which continue to this day. Traditional positron annihilation spectroscopic techniques, including lifetime studies, angular correlation, and Doppler broadening of annihilation radiation, are still being applied to new problems in the bulk properties of simple metals and their alloys. In addition new techniques based on tunable sources of monoenergetic positron beams have, in the last 5 years, expanded the horizons to studies of surfaces, thin films, and interfaces. In the present paper we briefly review these experimental techniques, illustrating with some of the important accomplishments of the field. 40 refs., 19 figs.

  8. Positron emitter labeled enzyme inhibitors

    DOEpatents

    Fowler, Joanna S.; MacGregor, Robert R.; Wolf, Alfred P.; Langstrom, Bengt

    1990-01-01

    This invention involves a new strategy for imaging and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography.

  9. Positron emitter labeled enzyme inhibitors

    SciTech Connect

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.; Langstrom, B.

    1990-04-03

    This invention involves a new strategy for imaging and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography.

  10. Positron emitter labeled enzyme inhibitors

    DOEpatents

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.

    1987-05-22

    This invention involved a new strategy for imaging and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide in activators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography. 2 figs.

  11. Positron-alkali atom scattering

    NASA Technical Reports Server (NTRS)

    Mceachran, R. P.; Horbatsch, M.; Stauffer, A. D.; Ward, S. J.

    1990-01-01

    Positron-alkali atom scattering was recently investigated both theoretically and experimentally in the energy range from a few eV up to 100 eV. On the theoretical side calculations of the integrated elastic and excitation cross sections as well as total cross sections for Li, Na and K were based upon either the close-coupling method or the modified Glauber approximation. These theoretical results are in good agreement with experimental measurements of the total cross section for both Na and K. Resonance structures were also found in the L = 0, 1 and 2 partial waves for positron scattering from the alkalis. The structure of these resonances appears to be quite complex and, as expected, they occur in conjunction with the atomic excitation thresholds. Currently both theoretical and experimental work is in progress on positron-Rb scattering in the same energy range.

  12. BID-F1 and BID-F2 domains of Bartonella henselae effector protein BepF trigger together with BepC the formation of invasome structures.

    PubMed

    Truttmann, Matthias C; Guye, Patrick; Dehio, Christoph

    2011-01-01

    The gram-negative, zoonotic pathogen Bartonella henselae (Bhe) translocates seven distinct Bartonella effector proteins (Beps) via the VirB/VirD4 type IV secretion system (T4SS) into human cells, thereby interfering with host cell signaling [1], [2]. In particular, the effector protein BepG alone or the combination of effector proteins BepC and BepF trigger massive F-actin rearrangements that lead to the establishment of invasome structures eventually resulting in the internalization of entire Bhe aggregates [2], [3]. In this report, we investigate the molecular function of the effector protein BepF in the eukaryotic host cell. We show that the N-terminal [E/T]PLYAT tyrosine phosphorylation motifs of BepF get phosphorylated upon translocation but do not contribute to invasome-mediated Bhe uptake. In contrast, we found that two of the three BID domains of BepF are capable to trigger invasome formation together with BepC, while a mutation of the WxxxE motif of the BID-F1 domain inhibited its ability to contribute to the formation of invasome structures. Next, we show that BepF function during invasome formation can be replaced by the over-expression of constitutive-active Rho GTPases Rac1 or Cdc42. Finally we demonstrate that BID-F1 and BID-F2 domains promote the formation of filopodia-like extensions in NIH 3T3 and HeLa cells as well as membrane protrusions in HeLa cells, suggesting a role for BepF in Rac1 and Cdc42 activation during the process of invasome formation.

  13. BID-F1 and BID-F2 Domains of Bartonella henselae Effector Protein BepF Trigger Together with BepC the Formation of Invasome Structures

    PubMed Central

    Truttmann, Matthias C.; Guye, Patrick; Dehio, Christoph

    2011-01-01

    The gram-negative, zoonotic pathogen Bartonella henselae (Bhe) translocates seven distinct Bartonella effector proteins (Beps) via the VirB/VirD4 type IV secretion system (T4SS) into human cells, thereby interfering with host cell signaling [1], [2]. In particular, the effector protein BepG alone or the combination of effector proteins BepC and BepF trigger massive F-actin rearrangements that lead to the establishment of invasome structures eventually resulting in the internalization of entire Bhe aggregates [2], [3]. In this report, we investigate the molecular function of the effector protein BepF in the eukaryotic host cell. We show that the N-terminal [E/T]PLYAT tyrosine phosphorylation motifs of BepF get phosphorylated upon translocation but do not contribute to invasome-mediated Bhe uptake. In contrast, we found that two of the three BID domains of BepF are capable to trigger invasome formation together with BepC, while a mutation of the WxxxE motif of the BID-F1 domain inhibited its ability to contribute to the formation of invasome structures. Next, we show that BepF function during invasome formation can be replaced by the over-expression of constitutive-active Rho GTPases Rac1 or Cdc42. Finally we demonstrate that BID-F1 and BID-F2 domains promote the formation of filopodia-like extensions in NIH 3T3 and HeLa cells as well as membrane protrusions in HeLa cells, suggesting a role for BepF in Rac1 and Cdc42 activation during the process of invasome formation. PMID:22043280

  14. Positron program at the Idaho Accelerator Center

    SciTech Connect

    Stancari, Giulio

    2009-09-02

    Positron physics is an important part of the research activities at the Idaho Accelerator Center (IAC). With positron annihilation spectroscopy, maps of nanodefects in materials have been obtained. For this purpose, positrons are generated by radioactive decay, photoactivation, or pair production. Preliminary tests of positron sources in the MeV range based on electron linacs have also been carried out at the IAC, and an expansion of this program is planned. A similar positron beam at Jefferson Lab would greatly improve our knowledge of the inner structure of the proton. In this paper, research with positrons at the IAC is reviewed. After a description of the Center's facilities, results from positron annihilation spectroscopy are discussed, together with future plans for testing a prototype positron source for CEBAF.

  15. Particle physics. Positrons ride the wave

    SciTech Connect

    Piot, Philippe

    2015-08-26

    Here, experiments reveal that positrons — the antimatter equivalents of electrons — can be rapidly accelerated using a plasma wave. The findings pave the way to high-energy electron–positron particle colliders.

  16. Positron-acoustic shock waves associated with cold viscous positron fluid in superthermal electron-positron-ion plasmas

    SciTech Connect

    Uddin, M. J. Alam, M. S.; Mamun, A. A.

    2015-06-15

    A theoretical investigation is made on the positron-acoustic (PA) shock waves (SHWs) in an unmagnetized electron-positron-ion plasma containing immobile positive ions, cold mobile positrons, and hot positrons and electrons following the kappa (κ) distribution. The cold positron kinematic viscosity is taken into account, and the reductive perturbation method is used to derive the Burgers equation. It is found that the viscous force acting on cold mobile positron fluid is a source of dissipation and is responsible for the formation of the PA SHWs. It is also observed that the fundamental properties of the PA SHWs are significantly modified by the effects of different parameters associated with superthermal (κ distributed) hot positrons and electrons.

  17. Positron microanalysis with high intensity beams

    SciTech Connect

    Hulett, L.D. Jr.; Donohue, D.L.

    1990-01-01

    One of the more common applications for a high intensity slow positron facility will be microanalysis of solid materials. In the first section of this paper some examples are given of procedures that can be developed. Since most of the attendees of this workshop are experts in positron spectroscopy, comprehensive descriptions will be omitted. With the exception of positron emission microscopy, most of the procedures will be based on those already in common use with broad beams. The utility of the methods have all been demonstrated, but material scientists use very few of them because positron microbeams are not generally available. A high intensity positron facility will make microbeams easier to obtain and partially alleviate this situation. All microanalysis techniques listed below will have a common requirement, which is the ability to locate the microscopic detail or area of interest and to focus the positron beam exclusively on it. The last section of this paper is a suggestion of how a high intensity positron facility might be designed so as to have this capability built in. The method will involve locating the specimen by scanning it with the microbeam of positrons and inducing a secondary electron image that will immediately reveal whether or not the positron beam is striking the proper portion of the specimen. This scanning positron microscope' will be a somewhat prosaic analog of the conventional SEM. It will, however, be an indispensable utility that will enhance the practicality of positron microanalysis techniques. 6 refs., 1 fig.

  18. Slow positron beam generator for lifetime studies

    NASA Technical Reports Server (NTRS)

    Singh, Jag J. (Inventor); Eftekhari, Abe (Inventor); St.clair, Terry L. (Inventor)

    1991-01-01

    A slow positron beam generator uses a conductive source residing between two test films. Moderator pieces are placed next to the test film on the opposite side of the conductive source. A voltage potential is applied between the moderator pieces and the conductive source. Incident energetic positrons: (1) are emitted from the conductive source; (2) are passed through test film; and (3) isotropically strike moderator pieces before diffusing out of the moderator pieces as slow positrons, respectively. The slow positrons diffusing out of moderator pieces are attracted to the conductive source which is held at an appropriate potential below the moderator pieces. The slow positrons have to pass through the test films before reaching the conductive source. A voltage is adjusted so that the potential difference between the moderator pieces and the conductive source forces the positrons to stop in the test films. Measurable annihilation radiation is emitted from the test film when positrons annihilate (combine) with electrons in the test film.

  19. Materials analysis using positron beam lifetime spectroscopy

    SciTech Connect

    Hartley, J.; Howell, R. H., Asoka-Kumar, P.; Sterne, P.; Stoeffl, W.

    1998-11-12

    We are using a defect analysis capabilities based on two positron beam lifetime spectrometers: the first is based on a 3 MeV electrostatic accelerator and the second on our high current linac beam. The high energy beam lifetime spectrometer is routinely used to perform positron lifetime analysis with a 3 MeV positron beam on thick sample specimens. It is being used for bulk sample analysis and analysis of samples encapsulated in controlled environments for in situ measurements. A second, low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy is under development at the LLNL high current positron source. This beam will enable defect-specific, 3-dimensional maps of defect concentration with sub-micron location resolution. When coupled with first principles calculations of defect specific positron lifetimes it will enable new levels of defect concentration mapping and defect identification.

  20. High intensity positron program at LLNL

    SciTech Connect

    Asoka-Kumar, P.; Howell, R.H.; Stoeffl, W.

    1998-09-23

    Lawrence Livermore National Laboratory (LLNL) is the home of the world's highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectra.

  1. Spin polarized low-energy positron source

    NASA Astrophysics Data System (ADS)

    Petrov, V. N.; Samarin, S. N.; Sudarshan, K.; Pravica, L.; Guagliardo, P.; Williams, J. F.

    2015-06-01

    This paper presents an investigation of spin polarization of positrons from a source based on the decay of 22Na isotopes. Positrons are moderated by transmission through a tungsten film and electrostatically focussed and transported through a 90 deg deflector to produce a slow positron beam with polarization vector normal to the linear momentum. The polarization of the beam was determined to be about 10% by comparison with polarized electron scattering asymmetries from a thin Fe film on W(110) at 10-10 Torr. Low energy electron emission from Fe layer on W(100) surfaces under positron impact is explored. It is shown that the intensity asymmetry of the electron emission as a function of the incident positron energy can be used to estimate the polarization of the positron beam. Also several materials with long mean free paths for spin relaxation are considered as possible moderators with increased polarization of the emergent positrons.

  2. Capture and polarization of positrons in a proposed NLC polarized positron source

    SciTech Connect

    Batygin, Yuri K

    2003-05-28

    A proposed NLC polarized positron source utilizes a 150 GeV electron beam passing through a helical undulator. The resulting flux of polarized photons is converted in a thin positron production target. Spin polarized positrons are captured using a high field flux concentrator followed by an accelerator section immersed in a solenoidal field. Positron tracking through the accelerating and focusing systems is done together with integration of spin precession. Optimization of the collection system is performed to insure high positron yield into the 6-dimensional acceptance of the subsequent pre-damping ring while keeping the high value of positron beam polarization.

  3. Positron confinement in embedded lithium nanoclusters

    NASA Astrophysics Data System (ADS)

    van Huis, M. A.; van Veen, A.; Schut, H.; Falub, C. V.; Eijt, S. W.; Mijnarends, P. E.; Kuriplach, J.

    2002-02-01

    Quantum confinement of positrons in nanoclusters offers the opportunity to obtain detailed information on the electronic structure of nanoclusters by application of positron annihilation spectroscopy techniques. In this work, positron confinement is investigated in lithium nanoclusters embedded in monocrystalline MgO. These nanoclusters were created by means of ion implantation and subsequent annealing. It was found from the results of Doppler broadening positron beam analysis that approximately 92% of the implanted positrons annihilate in lithium nanoclusters rather than in the embedding MgO, while the local fraction of lithium at the implantation depth is only 1.3 at. %. The results of two-dimensional angular correlation of annihilation radiation confirm the presence of crystalline bulk lithium. The confinement of positrons is ascribed to the difference in positron affinity between lithium and MgO. The nanocluster acts as a potential well for positrons, where the depth of the potential well is equal to the difference in the positron affinities of lithium and MgO. These affinities were calculated using the linear muffin-tin orbital atomic sphere approximation method. This yields a positronic potential step at the MgO||Li interface of 1.8 eV using the generalized gradient approximation and 2.8 eV using the insulator model.

  4. Bruno Touschek: From Betatrons to Electron-Positron Colliders

    NASA Astrophysics Data System (ADS)

    Bernardini, Carlo; Pancheri, Giulia; Pellegrini, Claudio

    Bruno Touschek's life as a physicist spanned the period from World War II to the 1970s. He was a key figure in the developments of electron-positron colliders and storage rings, and made important contributions to theoretical high energy physics. Storage rings, initially developed for high energy physics, are being widely used in many countries as synchrotron radiation sources and are a tool for research in physics, chemistry, biology, environmental sciences and cultural heritage studies. We describe Touschek's life in Austria, where he was born, in Germany, where he participated in the construction of a betatron during WWII, and in Italy, where he proposed and led to completion the first electron-positron storage ring in 1960, in Frascati. We highlight how his central European culture influenced his lifestyle and work, and his main contributions to physics, such as the discovery of the Touschek effect and beam instabilities in the larger storage ring ADONE.

  5. Bruno Touschek: From Betatrons to Electron-Positron Colliders

    NASA Astrophysics Data System (ADS)

    Bernardini, Carlo; Pancheri, Giulia; Pellegrini, Claudio

    Bruno Touschek’s life as a physicist spanned the period from World War II to the 1970s. He was a key figure in the developments of electron-positron colliders and storage rings, and made important contributions to theoretical high energy physics. Storage rings, initially developed for high energy physics, are being widely used in many countries as synchrotron radiation sources and are a tool for research in physics, chemistry, biology, environmental sciences and cultural heritage studies. We describe Touschek’s life in Austria, where he was born, in Germany, where he participated in the construction of a betatron during WWII, and in Italy, where he proposed and led to completion the first electron-positron storage ring in 1960, in Frascati. We highlight how his central European culture influenced his lifestyle and work, and his main contributions to physics, such as the discovery of the Touschek effect and beam instabilities in the larger storage ring ADONE.

  6. Positron-annihilation spectroscopy of defects in metals: an assessment

    SciTech Connect

    Siegel, R.W.

    1982-06-01

    Positron annihilation spectroscopy (PAS) has made significant contributions to our knowledge regarding lattice defects in metals in two areas: (i) the determination of atomic defect properties, particularly those of monovacancies, and (ii) the monitoring and characterization of vacancy-like microstructure development during post-irradiation of post-quench annealing. The application of PAS to the study of defects in metals is selectively reviewed and critically assessed within the context of other available techniques for such investigations. Possibilities for using the positron as a localized probe of the structure of atomic defects are discussed. Finally, the present status and future potential of PAS as a tool for the study of defects in metals are considered relative to other available techniques. 92 references, 20 figures.

  7. Nonplanar positron-acoustic Gardner solitary waves in electron-positron-ion plasmas with superthermal electrons and positrons

    NASA Astrophysics Data System (ADS)

    Uddin, M. J.; Alam, M. S.; Mamun, A. A.

    2015-02-01

    Nonplanar (cylindrical and spherical) positron-acoustic (PA) Gardner solitary waves (SWs) in an unmagnetized plasma system consisting of immobile positive ions, mobile cold positrons, and superthermal (kappa distributed) hot positrons and electrons are investigated. The modified Gardner equation is derived by using the reductive perturbation technique. The effects of cylindrical and spherical geometries, superthermal parameter of hot positrons and electrons, relative temperature ratios, and relative number density ratios on the PA Gardner SWs are studied by using the numerical simulations. The implications of our results in various space and laboratory plasma environments are briefly discussed.

  8. Nonplanar positron-acoustic Gardner solitary waves in electron-positron-ion plasmas with superthermal electrons and positrons

    SciTech Connect

    Uddin, M. J. Alam, M. S.; Mamun, A. A.

    2015-02-15

    Nonplanar (cylindrical and spherical) positron-acoustic (PA) Gardner solitary waves (SWs) in an unmagnetized plasma system consisting of immobile positive ions, mobile cold positrons, and superthermal (kappa distributed) hot positrons and electrons are investigated. The modified Gardner equation is derived by using the reductive perturbation technique. The effects of cylindrical and spherical geometries, superthermal parameter of hot positrons and electrons, relative temperature ratios, and relative number density ratios on the PA Gardner SWs are studied by using the numerical simulations. The implications of our results in various space and laboratory plasma environments are briefly discussed.

  9. Positron annihilation induced Auger electron spectroscopy

    NASA Technical Reports Server (NTRS)

    Weiss, Alex; Koymen, A. R.; Mehl, David; Jensen, K. O.; Lei, Chun; Lee, K. H.

    1990-01-01

    Recently, Weiss et al. have demonstrated that it is possible to excite Auger transitions by annihilating core electrons using a low energy (less than 30eV) beam of positrons. This mechanism makes possible a new electron spectroscopy, Positron annihilation induced Auger Electron Spectroscopy (PAES). The probability of exciting an Auger transition is proportional to the overlap of the positron wavefunction with atomic core levels. Since the Auger electron energy provides a signature of the atomic species making the transition, PAES makes it possible to determine the overlap of the positron wavefunction with a particular element. PAES may therefore provide a means of detecting positron-atom complexes. Measurements of PAES intensities from clean and adsorbate covered Cu surfaces are presented which indicate that approx. 5 percent of positrons injected into CU at 25eV produce core annihilations that result in Auger transitions.

  10. Positron annihilation in the interstellar medium

    NASA Technical Reports Server (NTRS)

    Guessoum, Nidhal; Ramaty, Reuven; Lingenfelter, Richard E.

    1991-01-01

    Positronium formation and annihilation are studied in a model for the interstellar medium consisting of cold cloud cores, warm partially ionized cloud envelopes, and hot intercloud gas. The gamma-ray spectra resulting from positron annihilation in these components of the interstellar medium are calculated. The spectra from the individual components are then combined, using two limiting assumptions for the propagation of the positrons, namely, that the positrons propagate freely throughout the interstellar medium, and that the positrons are excluded from the cold cloud cores. In the first case, the bulk of the positrons annihilate in the cloud cores and the annihilation line exhibits broad wings resulting from the annihilation of positronium formed by charge exchange in flight. In the second case, the positrons annihilate mainly in the warm envelopes, and the line wings are suppressed.

  11. Positron study of annealing of gallium arsenide

    SciTech Connect

    Rice-Evans, P.C.; Smith, D.L.; Evans, H.E.; Gledhill, G.A. )

    1991-02-01

    A positron beam has been used to investigate the sub-surface changes in semi-insulating gallium arsenide which had been annealed to a range of temperatures. The variations of the Doppler S parameter as a function of positron implantation energy, when subjected to a diffusion analysis, indicate variations in positron trapping at different depths. The results indicate the changes in the type of point defect that accompany the annealing.

  12. Initial results of positron ionization mass spectrometry

    NASA Technical Reports Server (NTRS)

    Donohue, D. L.; Hulett, L. D., Jr.; Mcluckey, S. A.; Glish, G. L.; Eckenrode, B. A.

    1990-01-01

    The use of monoenergetic positrons for the ionization of organic molecules in the gas phase is described. The ionic products are analyzed with a time-of-flight mass spectrometer and detected to produce a mass spectrum. The ionization mechanisms which can be studied in this way include positron impact at energies above the ionization limit of the target molecules, positronium formation in the Ore gap energy range, and positron attachment at energies less than 1eV. The technique of positron ionization mass spectrometry (PIMS) may have analytical utility in that chemical selectivity is observed for one or more of these processes.

  13. Applications and advances of positron beam spectroscopy

    SciTech Connect

    Howell, R., LLNL

    1998-03-18

    Over 50 scientists from DOE-DP, DOE-ER, the national laboratories, academia and industry attended a workshop held on November 5-7, 1997 at Lawrence Livermore National Laboratory. Workshop participants were charged to address two questions: Is there a need for a national center for materials analysis using positron techniques and can the capabilities at Lawrence Livermore National Laboratory serve this need. To demonstrate the need for a national center, the workshop participants discussed the technical advantages enabled by high positron currents and advanced measurement techniques, the role that these techniques would play in materials analysis and the demand for the data. Livermore now leads the world in materials analysis capabilities by positrons due to developments in response to demands of stockpile stewardship. The Livermore facilities now include the world`s highest current beam of keV positrons, a scanning pulsed positron microprobe under development capable of three dimensional maps of defect size and concentration, an MeV positron beam for defect analysis of large samples, and electron momentum spectroscopy by positrons. It was concluded that the positron microprobe under development at LLNL and other new instruments that would be relocated at LLNL at the high current keV source are an exciting step forward in providing results for the positron technique. These new data will impact a wide variety of applications.

  14. Matrix Isolation Spectroscopy Applied to Positron Moderatioin in Cryogenic Solids

    DTIC Science & Technology

    2011-07-01

    nanoseconds. Positrons that reach a free surface of the moderator before annihilating with an electron may escape into vacuum where they can be...0324. 3 • The positron (e+) is the antiparticle to the electron (e-). • Positrons are stable, but annihilate with electrons to produce γ-rays...Current Positron Applications • 2-γ decay exploited in Positron Emission Tomography (PET) scanners. • Positrons localize & annihilate preferentially at

  15. On the method of positron lifetime measurement

    NASA Technical Reports Server (NTRS)

    Nishiyama, F.; Shizuma, K.; Nasai, H.; Nishi, M.

    1983-01-01

    A fast-slow coincidence system was constructed for the measurement of positron lifetimes in material. The time resolution of this system was 270 ps for the (60)Co gamma rays. Positron lifetime spectra for 14 kinds of alkali halides were measured with this system. Two lifetime components and their intensities were derived from analyses of the lifetime spectra.

  16. Descriptions of positron defect analysis capabilities

    SciTech Connect

    Howell, R.H.

    1994-10-01

    A series of descriptive papers and graphics appropriate for distribution to potential collaborators has been assembled. These describe the capabilities for defect analysis using positron annihilation spectroscopy. The application of positrons to problems in the polymer and semiconductor industries is addressed.

  17. 21 CFR 892.1110 - Positron camera.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Positron camera. 892.1110 Section 892.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1110 Positron camera. (a) Identification. A...

  18. 21 CFR 892.1110 - Positron camera.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Positron camera. 892.1110 Section 892.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1110 Positron camera. (a) Identification. A...

  19. 21 CFR 892.1110 - Positron camera.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Positron camera. 892.1110 Section 892.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1110 Positron camera. (a) Identification. A...

  20. 21 CFR 892.1110 - Positron camera.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Positron camera. 892.1110 Section 892.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1110 Positron camera. (a) Identification. A...

  1. 21 CFR 892.1110 - Positron camera.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Positron camera. 892.1110 Section 892.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1110 Positron camera. (a) Identification. A...

  2. Ionisation of atomic hydrogen by positron impact

    NASA Technical Reports Server (NTRS)

    Spicher, Gottfried; Olsson, Bjorn; Raith, Wilhelm; Sinapius, Guenther; Sperber, Wolfgang

    1990-01-01

    With the crossed beam apparatus the relative impact-ionization cross section of atomic hydrogen by positron impact was measured. A layout of the scattering region is given. The first measurements on the ionization of atomic hydrogen by positron impact are also given.

  3. Positron collisions with alkali-metal atoms

    NASA Technical Reports Server (NTRS)

    Gien, T. T.

    1990-01-01

    The total cross sections for positron and electron collisions with potassium, sodium, lithium and rubidium are calculated, employing the modified Glauber approximation. The Modified Glauber cross sections for positron collision with potassium and sodium at low intermediate energies are found to agree reasonably well with existing experimental data.

  4. Electron and Positron Stopping Powers of Materials

    National Institute of Standards and Technology Data Gateway

    SRD 7 NIST Electron and Positron Stopping Powers of Materials (PC database for purchase)   The EPSTAR database provides rapid calculations of stopping powers (collisional, radiative, and total), CSDA ranges, radiation yields and density effect corrections for incident electrons or positrons with kinetic energies from 1 keV to 10 GeV, and for any chemically defined target material.

  5. Nondestructive examination using neutron activated positron annihilation

    DOEpatents

    Akers, Douglas W.; Denison, Arthur B.

    2001-01-01

    A method is provided for performing nondestructive examination of a metal specimen using neutron activated positron annihilation wherein the positron emitter source is formed within the metal specimen. The method permits in situ nondestructive examination and has the advantage of being capable of performing bulk analysis to determine embrittlement, fatigue and dislocation within a metal specimen.

  6. Positronic complexes with unnatural parity

    SciTech Connect

    Bromley, M. W. J.; Mitroy, J.; Varga, K.

    2007-06-15

    The structure of the unnatural parity states of PsH, LiPs, NaPs, and KPs are investigated with the configuration interaction and stochastic variational methods. The binding energies (in hartree) are found to be 8.17x10{sup -4}, 4.42x10{sup -4}, 15.14x10{sup -4}, and 21.80x10{sup -4}, respectively. These states are constructed by first coupling the two electrons into a configuration which is predominantly {sup 3}P{sup e}, and then adding a p-wave positron. All the active particles are in states in which the relative angular momentum between any pair of particles is at least L=1. The LiPs state is Borromean since there are no three-body bound subsystems (of the correct symmetry) of the (Li{sup +}, e{sup -}, e{sup -}, e{sup +}) particles that make up the system. The dominant decay mode of these states will be radiative decay into a configuration that autoionizes or undergoes positron annihilation.

  7. Positron beam studies of transients in semiconductors

    NASA Astrophysics Data System (ADS)

    Beling, C. D.; Ling, C. C.; Cheung, C. K.; Naik, P. S.; Zhang, J. D.; Fung, S.

    2006-02-01

    Vacancy-sensing positron deep level transient spectroscopy (PDLTS) is a positron beam-based technique that seeks to provide information on the electronic ionization levels of vacancy defects probed by the positron through the monitoring of thermal transients. The experimental discoveries leading to the concept of vacancy-sensing PDLTS are first reviewed. The major problem associated with this technique is discussed, namely the strong electric fields establish in the near surface region of the sample during the thermal transient which tend to sweep positrons into the contact with negligible defect trapping. New simulations are presented which suggest that under certain conditions a sufficient fraction of positrons may be trapped into ionizing defects rendering PDLTS technique workable. Some suggestions are made for techniques that might avoid the problematic electric field problem, such as optical-PDLTS where deep levels are populated using light and the use of high forward bias currents for trap filling.

  8. Design Issues for the ILC Positron Source

    SciTech Connect

    Bharadwaj, V.; Batygin, Yu.K.; Pitthan, R.; Schultz, D.C.; Sheppard, J.; Vincke, H.; Wang, J.W.; Gronberg, J.; Stein, W.; /LLNL, Livermore

    2006-02-15

    A positron source for the International Linear Collider (ILC) can be designed using either a multi-GeV electron beam or a multi-MeV photon beam impinging on a metal target. The major design issues are: choice of drive beam and its generation, choice of target material, the target station, positron capture section, target vault and beam transport to the ILC positron damping ring complex. This paper lists the ILC positron source requirements and their implications for the design of the positron source. A conceptual design for the ILC is expected to be finished in the next two years. With emphasis on this timescale, source design issues and possible solutions are discussed.

  9. Evidence for a significant mixture of electron/positron pairs in FRII jets constrained by cocoon dynamics

    NASA Astrophysics Data System (ADS)

    Kawakatu, Nozomu; Kino, Motoki; Takahara, Fumio

    2016-03-01

    We examine the plasma composition of relativistic jets in four Fanaroff-Riley type II (FRII) radio galaxies by analysing the total cocoon pressure in terms of partial pressures of thermal and non-thermal electrons/positrons and protons. The total cocoon pressure is determined by cocoon dynamics via comparison of theoretical model with the observed cocoon shape. By inserting the observed number density of non-thermal electrons/positrons and the upper limit of thermal electron/positron number density into the equation of state, the number density of protons is constrained. We apply this method to four FRII radio galaxies (Cygnus A, 3C 219, 3C 223 and 3C 284), for which the total cocoon pressures have been already evaluated. We find that the positron-free plasma comprising protons and electrons is ruled out, when we consider plausible particle distribution functions. In other words, the mixture of positrons is required for all four FRII radio galaxies; the number density ratio of electrons/positrons to protons is larger than 2. Thus, we find that the plasma composition is independent of the jet power and the size of cocoons. We also investigate the additional contribution of thermal electrons/positrons and protons on the cocoon dynamics. When thermal electrons/positrons are absent, the cocoon is supported by the electron/proton plasma pressure, while both electron/positron pressure supported and electron/proton plasma pressure supported cocoons are allowed if the number density of thermal electrons/positrons is about 10 times larger than that of non-thermal ones.

  10. Positron emission tomography: An overview

    PubMed Central

    Shukla, A. K.; Kumar, Utham

    2006-01-01

    The rate of glucose utilization in tumor cells is significantly enhanced as compared to normal cells and this biochemical characteristic is utilized in PET imaging using FDG as a major workhorse. The PET systems as well as cyclotrons producing positron emitting radiopharmaceuticals have undergone continuous technological refinements. While PET (CT) systems enable fusion images as well as precise attenuation correction, the self-shielded cyclotrons developed provide dedicated systems for in-house production of a large number of PET radiopharmaceuticals. The application of PET images in oncology includes those of pulmonary, colorectal, breast, lymphoma, head & neck, bone, ovarian and GI cancers. The PET has been recognized as promising diagnostic tool to predict biological and physiological changes at the molecular level and hence offer a potential area for future applications including Stem Cell research. PMID:21206635

  11. Positron emission tomography wrist detector

    DOEpatents

    Schlyer, David J.; O'Connor, Paul; Woody, Craig; Junnarkar, Sachin Shrirang; Radeka, Veljko; Vaska, Paul; Pratte, Jean-Francois

    2006-08-15

    A method of serially transferring annihilation information in a compact positron emission tomography (PET) scanner includes generating a time signal representing a time-of-occurrence of an annihilation event, generating an address signal representing a channel detecting the annihilation event, and generating a channel signal including the time and address signals. The method also includes generating a composite signal including the channel signal and another similarly generated channel signal concerning another annihilation event. An apparatus that serially transfers annihilation information includes a time signal generator, address signal generator, channel signal generator, and composite signal generator. The time signal is asynchronous and the address signal is synchronous to a clock signal. A PET scanner includes a scintillation array, detection array, front-end array, and a serial encoder. The serial encoders include the time signal generator, address signal generator, channel signal generator, and composite signal generator.

  12. Visible and dark matter genesis and cosmic positron and electron excesses

    SciTech Connect

    Gu Peihong; Sarkar, Utpal; Zhang Xinmin

    2009-10-01

    Dark and baryonic matter contribute comparable energy density to the present universe. The dark matter may also be responsible for the cosmic positron and electron excesses. We connect these phenomena with the Dirac seesaw for neutrino masses. In our model (i) the dark matter relic density is a dark matter asymmetry generated simultaneously with the baryon asymmetry so that we can naturally understand the coincidence between the dark and baryonic matter and (ii) the dark matter mostly decays into the leptons so that its decay can interpret the anomalous cosmic rays with positron and electron excesses.

  13. Multimode vibrational couplings in resonant positron annihilation.

    PubMed

    d'A Sanchez, Sergio; Lima, Marco A P; Varella, Márcio T do N

    2011-09-02

    The mechanisms for multimode vibrational couplings in resonant positron annihilation are not well understood. We show that these resonances can arise from positron-induced distortions of the potential energy surface (target response to the positron field). Though these distortions can transfer energy into single- and multiquantum vibrations, they have so far been disregarded as a pathway to resonant annihilation. We also compare the existing annihilation theories and show that the currently accepted model can be cast as a special case of the Feshbach annihilation theory.

  14. Prototyping of the ILC Baseline Positron Target

    SciTech Connect

    Gronberg, J; Brooksby, C; Piggott, T; Abbott, R; Javedani, J; Cook, E

    2012-02-29

    The ILC positron system uses novel helical undulators to create a powerful photon beam from the main electron beam. This beam is passed through a titanium target to convert it into electron-positron pairs. The target is constructed as a 1 m diameter wheel spinning at 2000 RPM to smear the 1 ms ILC pulse train over 10 cm. A pulsed flux concentrating magnet is used to increase the positron capture efficiency. It is cooled to liquid nitrogen temperatures to maximize the flatness of the magnetic field over the 1 ms ILC pulse train. We report on prototyping effort on this system.

  15. The Buffer-Gas Positron Accumulator and Resonances in Positron-Molecule Interactions

    NASA Technical Reports Server (NTRS)

    Surko, C.M.

    2007-01-01

    This is a personal account of the development of our buffer-gas positron trap and the new generation of cold beams that these traps enabled. Dick Drachman provided much appreciated advice to us from the time we started the project. The physics underlying trap operation is related to resonances (or apparent resonances) in positron-molecule interactions. Amusingly, experiments enabled by the trap allowed us to understand these processes. The positron-resonance "box score" to date is one resounding "yes," namely vibrational Feshbach resonances in positron annihilation on hydrocarbons; a "probably" for positron-impact electronic excitation of CO and NZ;an d a "maybe" for vibrational excitation of selected molecules. Two of these processes enabled the efficient operation of the trap, and one almost killed it in infancy. We conclude with a brief overview of further applications of the trapping technology discussed here, such as "massive" positron storage and beams with meV energy resolution.

  16. DEPFET detectors for future electron-positron colliders

    NASA Astrophysics Data System (ADS)

    Marinas, C.

    2015-11-01

    The DEPFET Collaboration develops highly granular, ultra-thin pixel detectors for outstanding vertex reconstruction at future electron-positron collider experiments. A DEPFET sensor, by the integration of a field effect transistor on a fully depleted silicon bulk, provides simultaneous position sensitive detector capabilities and in pixel amplification. The characterization of the latest DEPFET prototypes has proven that a adequate signal-to-noise ratio and excellent single point resolution can be achieved for a sensor thickness of 50 micrometers. The close to final auxiliary ASICs have been produced and found to operate a DEPFET pixel detector of the latest generation with the required read-out speed. A complete detector concept is being developed for the Belle II experiment at the new Japanese super flavor factory. DEPFET is not only the technology of choice for the Belle II vertex detector, but also a prime candidate for the ILC. Therefore, in this contribution, the status of DEPFET R&D project is reviewed in the light of the requirements of the vertex detector at a future electron-positron collider.

  17. Dark matter with multiannihilation channels and the AMS-02 positron excess and antiproton data

    NASA Astrophysics Data System (ADS)

    Chen, Yu-Heng; Cheung, Kingman; Tseng, Po-Yan

    2016-01-01

    AMS-02 provided the unprecedented statistics in the measurement of the positron fraction from cosmic rays. That may offer a unique opportunity to distinguish the positron spectrum coming from various dark matter (DM) annihilation channels, if DM is the source of this positron excess. Therefore, we consider the scenario that the DM can annihilate into leptonic, quark, and massive gauge-boson channels simultaneously with floating branching ratios to test this hypothesis. We also study the impacts from MAX, MED, MIN, and DC diffusion models as well as from isothermal, NFW, and Einasto DM density profiles on our results. We found two parameter regions that can satisfy both AMS-02 e/+ e++e- and p ¯/p data sets at 95% C.L.: (i) under the NFW-MIN combination with Mχ⊂[10 ,30 ] TeV , and (ii) under the Einasto-DC combination with Mχ⊂[500 ,1500 ] GeV .

  18. Positron annihilation spectroscopy on a beam of positrons the LEPTA facility

    NASA Astrophysics Data System (ADS)

    Ahmanova, E. V.; Eseev, M. K.; Kobets, A. G.; Meshkov, I. N.; Orlov, O. S.; Sidorin, A. A.; Siemek, K.; Horodek, P.

    2016-12-01

    The results and possibilities of the samples surfaces research by the Doppler method of positron annihilation spectroscopy (PAS) for a monochromatic beam of positrons at the LEPTA facility are presented in this paper. Method with high-resolution sensitivity to defects like vacancies and dislocations allows scanning of the surface and near-surface sample layers to a depth of several micrometers by the method of Doppler broadening of annihilation lines. The opportunities for the development of a PAS method based on the measurement of the positron lifetime in the sample irradiated by ordered flow of positrons from the injector of accelerator complex LEPTA at JINR are discussed.

  19. Bulk Materials Analysis Using High-Energy Positron Beams

    SciTech Connect

    Glade, S C; Asoka-Kumar, P; Nieh, T G; Sterne, P A; Wirth, B D; Dauskardt, R H; Flores, K M; Suh, D; Odette, G R

    2002-11-11

    This article reviews some recent materials analysis results using high-energy positron beams at Lawrence Livermore National Laboratory. We are combining positron lifetime and orbital electron momentum spectroscopic methods to provide electron number densities and electron momentum distributions around positron annihilation sites. Topics covered include: correlation of positron annihilation characteristics with structural and mechanical properties of bulk metallic glasses, compositional studies of embrittling features in nuclear reactor pressure vessel steel, pore characterization in Zeolites, and positron annihilation characteristics in alkali halides.

  20. Method of processing positron lifetime spectra

    SciTech Connect

    Valuev, N.P.; Klimov, A.B.; Zhikharev, A.N.

    1985-05-01

    This paper describes a method for the processing of spectra of positron annihilation which permits a much more relaible determination of the lifetime during numerical processing of spectra by computer.

  1. Positron kinetics in an idealized PET environment

    NASA Astrophysics Data System (ADS)

    Robson, R. E.; Brunger, M. J.; Buckman, S. J.; Garcia, G.; Petrović, Z. Lj.; White, R. D.

    2015-08-01

    The kinetic theory of non-relativistic positrons in an idealized positron emission tomography PET environment is developed by solving the Boltzmann equation, allowing for coherent and incoherent elastic, inelastic, ionizing and annihilating collisions through positronium formation. An analytic expression is obtained for the positronium formation rate, as a function of distance from a spherical source, in terms of the solutions of the general kinetic eigenvalue problem. Numerical estimates of the positron range - a fundamental limitation on the accuracy of PET, are given for positrons in a model of liquid water, a surrogate for human tissue. Comparisons are made with the ‘gas-phase’ assumption used in current models in which coherent scattering is suppressed. Our results show that this assumption leads to an error of the order of a factor of approximately 2, emphasizing the need to accurately account for the structure of the medium in PET simulations.

  2. Addiction Studies with Positron Emission Tomography

    ScienceCinema

    Joanna Fowler

    2016-07-12

    Brookhaven scientist Joanna Fowler describes Positron Emission Technology (PET) research at BNL which for the past 30 years has focused in the integration of basic research in radiotracer chemistry with the tools of neuroscience to develop new scientific

  3. Addiction Studies with Positron Emission Tomography

    SciTech Connect

    Joanna Fowler

    2008-10-13

    Brookhaven scientist Joanna Fowler describes Positron Emission Technology (PET) research at BNL which for the past 30 years has focused in the integration of basic research in radiotracer chemistry with the tools of neuroscience to develop new scientific

  4. Electric charges of positrons and antiprotons

    SciTech Connect

    Hughes, R.J. ); Deutch, B.I. )

    1992-07-27

    Tests of the electric charges carried by the positron and antiproton are derived from recent measurements of the cyclotron frequencies of these particles, and from the spectroscopy of exotic atoms in which they are constituents.

  5. Electron and positron induced processes. POSMOL 2013

    NASA Astrophysics Data System (ADS)

    Limão-Vieira, Paulo; Campeanu, Radu; Hoshino, Masamitsu; Ingólfsson, Oddur; Mason, Nigel; Nagashima, Yasuyuki; Tanuma, Hajime

    2014-09-01

    POSMOL 2013, the international meeting on electron and positron induced processes comprising the XVII International Workshop on Low-Energy Positron and Positronium Physics and the XVIII International Symposium on Electron-Molecule Collisions and Swarms, was held at Kanazawa Bunka Hall, Kanazawa, Ishikawa, Japan, from 19-21 July 2013. The XVII Workshop encompassed all aspects of positron, positronium and antiproton interactions with electrons, atoms, molecules and solid surfaces, and topics related to these, whereas the XVIII Symposium encompassed all aspects of electron interactions with molecules in both gaseous and condensed phases. Particular topics include studies of electron interactions with biomolecules, electron induced surface chemistry and the study of plasma processes. Recent research on the study of electron swarms was also highlighted. Contribution to the Topical Issue "Electron and Positron Induced Processes", edited by Michael Brunger, Radu Campeanu, Masamitsu Hoshino, Oddur Ingólfsson, Paulo Limão-Vieira, Nigel Mason, Yasuyuki Nagashima and Hajime Tanuma.

  6. Positron annihilation induced Auger electron emission

    SciTech Connect

    Weiss, A.; Jibaly, M.; Lei, Chun; Mehl, D.; Mayer, R.; Lynn, K.G.

    1988-01-01

    We report on measurements of Auger electron emission from Cu and Fe due to core hole excitations produced by the removal of core electrons by matter-antimatter annihilation. Estimates are developed of the probability of positrons annihilating with a 3p electron in these materials. Several important advantages of Positron annihilation induced Auger Electron Spectroscopy (PAES) for surface analysis are suggested. 10 refs., 2 figs.

  7. Thermal positron interactions with alkali covered tungsten

    NASA Astrophysics Data System (ADS)

    Yamashita, Takashi; Iida, Shimpei; Terabe, Hiroki; Nagashima, Yasuyuki

    2016-11-01

    The branching ratios of positron reemission, positronium emission, positronium negative ion emission and capture to the surface state for thermalized positrons at polycrystalline tungsten surfaces coated with Na, K and Cs have been measured. The data shows that the ratios depend on the coverage of the alkali-metal coating. The fraction of the emitted positronium increases with the coverage of the coating up to 90%.

  8. Modulation of a quantum positron acoustic wave

    NASA Astrophysics Data System (ADS)

    Amin, M. R.

    2015-09-01

    Amplitude modulation of a positron acoustic wave is considered in a four-component electron-positron plasma in the quantum magnetohydrodynamic regime. The important ingredients of this study are the inclusion of the particle exchange-correlation potential, quantum diffraction effects via the Bohm potential, and dissipative effect due to viscosity in the momentum balance equation of the charged carriers. A modified nonlinear Schrödinger equation is derived for the evolution of the slowly varying amplitude of the quantum positron acoustic wave by employing the standard reductive perturbation technique. Detailed analysis of the linear and nonlinear dispersions of the quantum positron acoustic wave is presented. For a typical parameter range, relevant to some dense astrophysical objects, it is found that the quantum positron acoustic wave is modulationally unstable above a certain critical wavenumber. Effects of the exchange-correlation potential and the Bohm potential in the wave dynamics are also studied. It is found that the quantum effect due to the particle exchange-correlation potential is significant in comparison to the effect due to the Bohm potential for smaller values of the carrier wavenumber. However, for comparatively larger values of the carrier wavenumber, the Bohm potential effect overtakes the effect of the exchange-correlation potential. It is found that the critical wavenumber for the modulation instability depends on the ratio of the equilibrium hot electron number density and the cold positron number density and on the ratio of the equilibrium hot positron number density and the cold positron number density. A numerical result on the growth rate of the modulation instability is also presented.

  9. Positron annihilation studies of organic superconductivity

    SciTech Connect

    Yen, H.L.; Lou, Y.; Ali, E.H.

    1994-09-01

    The positron lifetimes of two organic superconductors, {kappa}-(ET){sub 2}Cu(NCS){sub 2} and {kappa}-(ET){sub 2}Cu[N(CN){sub 2}]Br, are measured as a function of temperature across {Tc}. A drop of positron lifetime below {Tc} is observed. Positron-electron momentum densities are measured by using 2D-ACAR to search for the Fermi surface in {kappa}-(ET){sub 2}Cu[N(CN){sub 2}]Br. Positron density distributions and positron-electron overlaps are calculated by using the orthogonalized linear combination atomic orbital (OLCAO) method to interprete the temperature dependence due to the local charge transfer which is inferred to relate to the superconducting transition. 2D-ACAR results in {kappa}-(ET){sub 2}Cu[N(CN){sub 2}]Br are compared with theoretical band calculations based on a first-principles local density approximation. Importance of performing accurate band calculations for the interpretation of positron annihilation data is emphasized.

  10. The PEP-II design

    SciTech Connect

    Sullivan, M.K.

    1995-05-01

    The Stanford Linear Accelerator Center (SLAC), Lawrence Berkeley Laboratory (LBL), Lawrence Livermore National Laboratory (LLNL) Positron Electron Project-II (PEP-II) is a design for a high-luminosity, asymmetric energy, electron-positron colliding beam accelerator that will operate at the center-of-mass energy of the {Upsilon}4S (10.58 GeV). The goal of the design is to achieve a large enough integrated luminosity with a moving center-of-mass reference frame to he able to observe the predicted rare decay modes of the {Upsilon}4S that do not conserve charge parity (CP).

  11. Intense low energy positron beams

    SciTech Connect

    Lynn, K.G.; Jacobsen, F.M.

    1993-12-31

    Intense positron beams are under development or being considered at several laboratories. Already today a few accelerator based high intensity, low brightness e{sup +} beams exist producing of the order of 10{sup 8} {minus} 10{sup 9} e{sup +}/sec. Several laboratories are aiming at high intensity, high brightness e{sup +} beams with intensities greater than 10{sup 9} e{sup +}/sec and current densities of the order of 10{sup 13} {minus} 10{sup 14} e{sup +} sec{sup {minus}} {sup 1}cm{sup {minus}2}. Intense e{sup +} beams can be realized in two ways (or in a combination thereof) either through a development of more efficient B{sup +} moderators or by increasing the available activity of B{sup +} particles. In this review we shall mainly concentrate on the latter approach. In atomic physics the main trust for these developments is to be able to measure differential and high energy cross-sections in e{sup +} collisions with atoms and molecules. Within solid state physics high intensity, high brightness e{sup +} beams are in demand in areas such as the re-emission e{sup +} microscope, two dimensional angular correlation of annihilation radiation, low energy e{sup +} diffraction and other fields. Intense e{sup +} beams are also important for the development of positronium beams, as well as exotic experiments such as Bose condensation and Ps liquid studies.

  12. Dynamics of the positron acoustic waves in electron-positron-ion magnetoplasmas

    NASA Astrophysics Data System (ADS)

    Ali, Rustam; Saha, Asit; Chatterjee, Prasanta

    2017-01-01

    Dynamics of the positron acoustic waves in electron-positron-ion (e-p-i) magnetoplasmas with κ-distributed hot electrons and positrons is investigated in the frameworks of the Kadomtsev-Petviashili (KP) and modified Kadomtsev-Petviashili (mKP) equations. Employing the reductive perturbation technique, the KP and mKP equations are derived. Using the bifurcation theory of planar dynamical systems, the positron acoustic solitary wave solutions, the kink and anti-kink wave solutions are obtained. Considering an external periodic perturbation in the electron-positron-ion magnetoplasmas, the perturbed KP and mKP equations are studied via some qualitative and quantitative approaches. To corroborate in the fact that the perturbed KP and mKP equations can indeed give rise to the quasiperiodic and chaotic motions, the phase plane plots, time series plots, and the Poincaré section are used. The quasiperiodic and developed chaos can be observed for the perturbed positron acoustic waves. The frequency (ω ) of the external periodic perturbation plays the role of the switching parameter in chaotic motions of the perturbed positron acoustic waves through quasiperiodic route to chaos. This work can be useful to understand the dynamics of nonlinear electromagnetic perturbations in space and laboratory plasmas consisting of κ-distributed hot electrons and positrons.

  13. Van de Graaff based positron source production

    NASA Astrophysics Data System (ADS)

    Lund, Kasey Roy

    The anti-matter counterpart to the electron, the positron, can be used for a myriad of different scientific research projects to include materials research, energy storage, and deep space flight propulsion. Currently there is a demand for large numbers of positrons to aid in these mentioned research projects. There are different methods of producing and harvesting positrons but all require radioactive sources or large facilities. Positron beams produced by relatively small accelerators are attractive because they are easily shut down, and small accelerators are readily available. A 4MV Van de Graaff accelerator was used to induce the nuclear reaction 12C(d,n)13N in order to produce an intense beam of positrons. 13N is an isotope of nitrogen that decays with a 10 minute half life into 13C, a positron, and an electron neutrino. This radioactive gas is frozen onto a cryogenic freezer where it is then channeled to form an antimatter beam. The beam is then guided using axial magnetic fields into a superconducting magnet with a field strength up to 7 Tesla where it will be stored in a newly designed Micro-Penning-Malmberg trap. Several source geometries have been experimented on and found that a maximum antimatter beam with a positron flux of greater than 0.55x10 6 e+s-1 was achieved. This beam was produced using a solid rare gas moderator composed of krypton. Due to geometric restrictions on this set up, only 0.1-1.0% of the antimatter was being frozen to the desired locations. Simulations and preliminary experiments suggest that a new geometry, currently under testing, will produce a beam of 107 e+s-1 or more.

  14. Elastic and inelastic scattering of positrons in gases and solids

    NASA Technical Reports Server (NTRS)

    Mcgowan, J. W.

    1972-01-01

    Three apparatuses were designed and built: The first, which is now operative, was designed to study the details of positron thermalization in solids and the subsequent emission of the low energy positrons from moderating foils; The second apparatus now under test is a positron bottle similar in design to an electron trap. It was built to store positrons at a fixed energy and to look at the number of stored positrons (storage time) as a function of a scattering gas in the vacuum chamber. The third apparatus is a crossed beam apparatus where positron-, alkali scattering will be studied. Much of the apparatus is now under test with electrons.

  15. Electron capture from solids by positrons

    SciTech Connect

    Howell, R.

    1987-08-01

    The capture of electrons in solids is modified from that in gasses by several factors. The most important is the collective interaction of the electrons which results in a density of electron states in the solid in wide bands. Also the high density of electrons in many solids gives a high frequency of interaction as compared to gasses, and quickly destroys any electron-positron states in the metal matrix. Consequently, most positrons implanted in a metal will rapidly thermalize, and unless they reach the surface will annihilate with an electron in an uncorrelated state. Positronium formation from positrons scattered at a metal surface is analogous to ion neutralization however, most of the positronium comes from positrons passing through the surface from the bulk. The dominant motivation for studying positronium formation has been the hope that the distribution of the electrons at the surface would be obtained through the annihilation properties of positrons trapped at the surface or through analysis of the energy and angular distributions of the positronium emitted into the vacuum. These distributions have been measured and are included in this paper. 17 refs.

  16. Current Issues in Electron and Positron Transport Theory

    NASA Astrophysics Data System (ADS)

    Robson, Robert

    2007-10-01

    In this paper we review the current status of transport theory for low energy electrons or positrons in gases, in the context of both kinetic theory and fluid modelling. In particular, we focus on the following issues: (i) Muliterm vs two-term representation of the velocity distribution function in solution of Boltzmann's equation; (ii) the effect of non-conservative collisions (attachment, ionization, positron annihilation) on transport properties; (iii) the enduring electron- hydrogen vibrational cross section controversy and possible implications for the Boltzmann equation itself; (iv) closure of the fluid equations and the heat flux ansatz; and (v) correct use of swarm transport coefficients in fluid modelling of low temperature plasmas. Both hydrodynamic and non-hydrodynamic examples will be given, with attention focussed on the Franck-Hertz experiment, particularly the ``window'' of fields in which oscillations of transport properties are produced, and the way in which electric and magnetic fields combine to affect transport properties. In collaboration with co-authors Z. LJ. Petrovi'c, Institute of Physics Belgrade, and R.D. White, James Cook University.

  17. Positive charge prevalence in cosmic rays: Room for dark matter in the positron spectrum

    NASA Astrophysics Data System (ADS)

    Malkov, M. A.; Diamond, P. H.; Sagdeev, R. Z.

    2016-09-01

    The unexpected energy spectrum of the positron/electron ratio is interpreted astrophysically, with a possible exception of the 100-300 GeV range. The data indicate that this ratio, after a decline between 0.5 and 8 GeV, rises steadily with a trend towards saturation at 200-400 GeV. These observations (except for the trend) appear to be in conflict with the diffusive shock acceleration (DSA) mechanism, operating in a single supernova remnant (SNR) shock. We argue that e+/e- ratio can still be explained by the diffusive shock acceleration if positrons are accelerated in a subset of SNR shocks which (i) propagate in clumpy gas media and (ii) are modified by accelerated cosmic ray protons. The protons penetrate into the dense gas clumps upstream to produce positrons and charge the clumps positively. The induced electric field expels positrons into the upstream plasma where they are shock accelerated. Since the shock is modified, these positrons develop a harder spectrum than that of the cosmic ray electrons accelerated in other SNRs. Mixing these populations explains the increase in the e+/e- ratio at E >8 GeV . It decreases at E <8 GeV because of a subshock weakening which also results from the shock modification. Contrary to the expelled positrons, most of the antiprotons, electrons, and heavier nuclei, are left unaccelerated inside the clumps. Scenarios for the 100-300 GeV AMS-02 fraction exceeding the model prediction, including, but not limited to, possible dark matter contribution, are also discussed.

  18. Unthermalized positrons in gamma ray burst sources

    NASA Technical Reports Server (NTRS)

    Tkaczyk, W.; Karakula, S.

    1992-01-01

    The spectra of the broadening 0.511 MeV annihilation line produced by high temperatures was calculated in the case of unthermalized plasma; i.e., T sub e(+) is not = T sub e(-). The flattening in the spectrum of the annihilation lines for large differences of electron and positron temperatures is a strong indication that the observed features of the hard tailed spectrum of the gamma bursts can be well described by annihilation of unthermalized positrons. It is proposed that the charge separation occurring in Eddington limited accretion onto a neutron star or the one photon pair production in strong magnetic fields as a mechanism for the production of unthermalized positrons in the sources of gamma bursts. From the best fit of experimental spectra by the model, the parameters of sources for which the regions with different plasma temperatures can exist is evaluated.

  19. Positron transport: The plasma-gas interface

    SciTech Connect

    Marler, J. P.; Petrovic, Z. Lj.; Bankovic, A.; Dujko, S.; Suvakov, M.; Malovic, G.; Buckman, S. J.

    2009-05-15

    Motivated by an increasing number of applications, new techniques in the analysis of electron transport have been developed over the past 30 years or so, but similar methods had yet to be applied to positrons. Recently, an in-depth look at positron transport in pure argon gas has been performed using a recently established comprehensive set of cross sections and well-established Monte Carlo simulations. The key novelty as compared to electron transport is the effect of positronium formation which changes the number of particles and has a strong energy dependence. This coupled with spatial separation by energy of the positron swarm leads to counterintuitive behavior of some of the transport coefficients. Finally new results in how the presence of an applied magnetic field affects the transport coefficients are presented.

  20. Defects in metals. [Positron annihilation spectroscopy

    SciTech Connect

    Siegel, R.W.

    1982-06-01

    The application of positron annihilation spectroscopy (PAS) to the study of defects in metals has led to increased knowledge on lattice-defect properties during the past decade in two areas: the determination of atomic defect properties, particularly those of monovacancies, and the monitoring and characterization of vacancy-like microstructure development during post-irradiation and post-quench annealing. The study of defects in metals by PAS is reviewed within the context of the other available techniques for defect studies. The strengths and weaknesses of PAS as a method for the characterization of defect microstructures are considered. The additional possibilities for using the positron as a localized probe of the atomic and electronic structures of atomic defects are discussed, based upon theoretical calculations of the annihilation characteristics of defect-trapped positrons and experimental observations. Finally, the present status and future potential of PAS as a tool for the study of defects in metals is considered. 71 references, 9 figures.

  1. Trapped positrons observed by PAMELA experiment

    NASA Astrophysics Data System (ADS)

    Mikhailov, V. V.; Adriani, O.; Barbarino, G.; Bazilevskaya, G. A.; Bellotti, R.; Boezio, M.; Bogomolov, E. A.; Bongi, M.; Bonvicini, V.; Bottai, S.; Bruno, A.; Cafagna, F. S.; Campana, D.; Carbone, R.; Carlson, P.; Casolino, M.; Castellini, G.; Consiglio, L.; De Santis, C.; De Simone, N.; Di Felice, V.; Galper, A. M.; Karelin, A. V.; Koldashov, S. V.; Koldobsky, S.; Krutkov, S. Yu; Kvashnin, A. N.; Leonov, A. A.; Malakhov, V. V.; Marcelli, L.; Martucci, M.; Mayorov, A. G.; Menn, W.; Merge, M.; Mocchiutti, E.; Monaco, A.; Mori, N.; Munini, R.; Osteria, G.; Papini, P.; Palma, F.; Panico, B.; Pearce, M.; Picozza, P.; Ricci, M.; Ricciarini, S. B.; Sarkar, R.; Scotti, V.; Simon, M.; Sparvoli, R.; Spillantini, P.; Stozhkov, Yu I.; Vacchi, A.; Vannuccini, E.; Vasiliev, G. I.; Voronov, S. A.; Yurkin, Yu T.; Zampa, G.; Zampa, N.

    2016-02-01

    Measurements of electron and positron spatial distributions in energy range from 80 MeV to several GeV below the geomagnetic cutoff rigidity were carried out using the PAMELA magnetic spectrometer. The instrument is installed on board the Resurs-DK satellite which was launched June 15th 2006 on an elliptical orbit with the inclination 70 degrees and the altitude 350-600 km. The procedure of trajectories calculations in the geomagnetic filed gives a way to separate stably trapped and short lived albedo components produced in interactions of cosmic ray protons with the residual atmosphere. The work presents spatial distributions of trapped, quasitrapped and short-lived albedo electrons and positrons in the near Earth space. Electron to positron ratio points out on different production mechanism of trapped and quasitrapped particles.

  2. Positron annihilation in solid and liquid Ni

    SciTech Connect

    Fluss, M.J.; Smedskjaer, L.C.; Chakraborty, B.; Chason, M.K.

    1982-03-01

    New techniques have been developed for the study of metals via positron annihilation which provide for the in-situ melting of the samples and subsequent measurements via Doppler broadening of positron-annihilation radiation. Here we report these metods currently in use at our laboratory; ion implantation of /sup 58/Co and the use of Al/sub 2/O/sub 3/ crucibles for in-situ melting followed by the decomposition of the Doppler-broadened spectrum into a parabolic and a Gaussian component. Our earliest results obtained for pure Ni in the polycrystalline solid and in the liquid state are compared. An interesting similarity is reported for the distributions of the high-momentum (Gaussian) component for positrons annihilating in vacancies at high temperatures and those annihilating in liquid Ni.

  3. Positron states and annihilation characteristics of surface-trapped positrons at the oxidized Cu(110) surface

    NASA Astrophysics Data System (ADS)

    Fazleev, N. G.; Olenga, Antoine; Weiss, A. H.

    2013-03-01

    The process by which oxide layers are formed on metal surfaces is still not well understood. In this work we present the results of theoretical studies of positron states and annihilation characteristics of surface-trapped positrons at the oxidized Cu(110) surface. An ab-initio investigation of stability and associated electronic properties of different adsorption phases of oxygen on Cu(110) has been performed on the basis of density functional theory and using DMOl3 code. The changes in the positron work function and the surface dipole moment when oxygen atoms occupy on-surface and sub-surface sites have been attributed to charge redistribution within the first two layers, buckling effects within each layer and interlayer expansion. The computed positron binding energy, positron surface state wave function, and annihilation probabilities of surface trapped positrons with relevant core electrons demonstrate their sensitivity to oxygen coverage, elemental content, atomic structure of the topmost layers of surfaces, and charge transfer effects. Theoretical results are compared with experimental data obtained from studies of oxidized transition metal surfaces using positron annihilation induced Auger electron spectroscopy. This work was supported in part by the National Science Foundation Grant DMR-0907679.

  4. Nonlinear excitations for the positron acoustic shock waves in dissipative nonextensive electron-positron-ion plasmas

    NASA Astrophysics Data System (ADS)

    Saha, Asit

    2017-03-01

    Positron acoustic shock waves (PASHWs) in unmagnetized electron-positron-ion (e-p-i) plasmas consisting of mobile cold positrons, immobile positive ions, q-nonextensive distributed electrons, and hot positrons are studied. The cold positron kinematic viscosity is considered and the reductive perturbation technique is used to derive the Burgers equation. Applying traveling wave transformation, the Burgers equation is transformed to a one dimensional dynamical system. All possible vector fields corresponding to the dynamical system are presented. We have analyzed the dynamical system with the help of potential energy, which helps to identify the stability and instability of the equilibrium points. It is found that the viscous force acting on cold mobile positron fluid is a source of dissipation and is responsible for the formation of the PASHWs. Furthermore, fully nonlinear arbitrary amplitude positron acoustic waves are also studied applying the theory of planar dynamical systems. It is also observed that the fundamental features of the small amplitude and arbitrary amplitude PASHWs are significantly affected by the effect of the physical parameters q e , q h , μ e , μ h , σ , η , and U. This work can be useful to understand the qualitative changes in the dynamics of nonlinear small amplitude and fully nonlinear arbitrary amplitude PASHWs in solar wind, ionosphere, lower part of magnetosphere, and auroral acceleration regions.

  5. Position-resolved Positron Annihilation Lifetime Spectroscopy

    NASA Astrophysics Data System (ADS)

    Wagner, A.; Butterling, M.; Fiedler, F.; Fritz, F.; Kempe, M.; Cowan, T. E.

    2013-06-01

    A new method which allows for position-resolved positron lifetime spectroscopy studies in extended volume samples is presented. In addition to the existing technique of in-situ production of positrons inside large (cm3) bulk samples using high-energy photons up to 16 MeV from bremsstrahlung production, granular position-sensitive photon detectors have been employed. A beam of intense bremsstrahlung is provided by the superconducting electron linear accelerator ELBE (Electron Linear Accelerator with high Brilliance and low Emittance) which delivers electron bunches of less than 10 ps temporal width and an adjustable bunch separation of multiples of 38 ns, average beam currents of 1 mA, and energies up to 40 MeV. Since the generation of bremsstrahlung and the transport to the sample preserves the sharp timing of the electron beam, positrons generated inside the entire sample volume by pair production feature a sharp start time stamp for positron annihilation lifetime studies with high timing resolutions and high signal to background ratios due to the coincident detection of two annihilation photons. Two commercially available detectors from a high-resolution medial positron-emission tomography system are being employed with 169 individual Lu2SiO5:Ce scintillation crystals, each. In first experiments, a positron-lifetime gated image of a planar Si/SiO2 (pieces of 12.5 mm × 25 mm size) sample and a 3-D structured metal in Teflon target could be obtained proving the feasibility of a three dimensional lifetime-gated tomographic system.

  6. Apparatus for photon activation positron annihilation analysis

    DOEpatents

    Akers, Douglas W.

    2007-06-12

    Non-destructive testing apparatus according to one embodiment of the invention comprises a photon source. The photon source produces photons having predetermined energies and directs the photons toward a specimen being tested. The photons from the photon source result in the creation of positrons within the specimen being tested. A detector positioned adjacent the specimen being tested detects gamma rays produced by annihilation of positrons with electrons. A data processing system operatively associated with the detector produces output data indicative of a lattice characteristic of the specimen being tested.

  7. NLC Positron Target Heating(LCC-0065)

    SciTech Connect

    Schultz, D

    2003-10-07

    The NLC requires an intense beam with a large number of positrons. These positrons are produced by a high energy electron beam impinging on a solid tungsten-rhenium alloy target. The particle shower that develops in the solid target deposits significant energy in the material, leading to target stresses and potentially to target damage. The stresses can be analyzed once the magnitude and extent of the energy deposition is known. This note details the modeling of the energy deposition using EGS, performed for the NLC and the SLC targets and for possible NLC targets made of copper or nickel instead of WRe.

  8. Preferential positron heating and acceleration by synchrotron maser instabilities in relativistic positron-electron-proton plasmas

    NASA Technical Reports Server (NTRS)

    Hoshino, Masahiro; Arons, Jonathan

    1991-01-01

    A new process of the preferential strong heating of positrons through the ion synchrotron maser instability in positron-electron-proton magnetized plasmas is investigated using particle-in-cell simulations. It is shown that the positrons form a nonthermal power-law-like energy distribution via their gyroresonant interaction with the extraordinary modes emitted by the ions. It is noted that this process may be of significance in connection with the shock excitation of nonthermal synchrotron radiation from astrophysical systems powered by relativistic outflows from compact central objects, e.g., supernova remnants powered by pulsars and jets from active galactic nuclei.

  9. Role of vibrational dynamics in resonant positron annihilation on molecules.

    PubMed

    Jones, A C L; Danielson, J R; Natisin, M R; Surko, C M

    2013-05-31

    Vibrational Feshbach resonances are dominant features of positron annihilation for incident positron energies in the range of the molecular vibrations. Studies in relatively small molecules are described that elucidate the role of intramolecular vibrational energy redistribution into near-resonant multimode states, and the subsequent coupling of these modes to the positron continuum, in suppressing or enhancing these resonances. The implications for annihilation in other molecular species, and the necessary ingredients of a more complete theory of resonant positron annihilation, are discussed.

  10. Future directions in high energy electron-positron experimentation

    SciTech Connect

    Trilling, G.H.

    1988-09-01

    In this report, the possibilities of studying particle physics at the TeV scale with high energy electron-positron linear colliders are discussed. A status report on the SLC and the MARK II program is given to provide some insights on the feasibility of experiments at linear colliders. The technical issues in going from SLC to the development of TeV colliders are briefly discussed. Some of the elements of the e/sup +/e/sup -/ experimental environment which differentiate it from that in hadron colliders and give examples of processes particularly well suited to attack by e/sup +/e/sup -/ annihilation are summarized. Finally, some concluding remarks are given. 8 refs., 10 figs., 2 tabs.

  11. Synthesis and characterization of magnesium oxide nanocrystallites and probing the vacancy-type defects through positron annihilation studies

    NASA Astrophysics Data System (ADS)

    Das, Anjan; Mandal, Atis Chandra; Roy, Soma; Prashanth, Pendem; Ahamed, Sk Izaz; Kar, Subhrasmita; Prasad, Mithun S.; Nambissan, P. M. G.

    2016-09-01

    Magnesium oxide nanocrystallites exhibit certain abnormal characteristics when compared to those of other wide band gap oxide semiconductors in the sense they are most prone to water absorption and formation of a hydroxide layer on the surface. The problem can be rectified by heating and pure nanocrystallites can be synthesized with controllable sizes. Inevitably the defect properties are distinctly divided between two stages, the one with the hydroxide layer (region I) and the other after the removal of the layer by annealing (region II). The lattice parameters, the optical band gap and even the positron annihilation characteristics are conspicuous by their distinct behavior in the two stages of the surface configurations of nanoparticles. While region I was specific with the formation of positronium-hydrogen complexes that drastically altered the defect-specific positron lifetimes, pick-off annihilation of orthopositronium atoms marked region II. The vacancy clusters within the nanocrystallites also trapped positrons. They agglomerated due to the effect of the higher temperatures and resulted in the growth of the nanocrystallites. The coincidence Doppler broadening spectroscopic measurements supported these findings and all the more indicated the trapping of positrons additionally into the neutral divacancies and negatively charged trivacancies. This is apart from the Mg2+ monovacancies which acted as the dominant trapping centers for positrons.

  12. Positron studies of defected metals, metallic surfaces. Final report, July 1, 1985--December 1, 1991

    SciTech Connect

    Bansil, A.

    1991-12-31

    Specific problems proposed under this project included the treatment of electronic structure and momentum density in various disordered and defected systems. Since 1987, when the new high-temperature superconductors were discovered, the project focused extensively on questions concerning the electronic structure and Fermiology of high-{Tc} superconductors, in particular, (i) momentum density and positron experiments, (ii) angle-resolved photoemission intensities, (iii) effects of disorder and substitutions in the high-{Tc}`s.

  13. Observation of Magnetic Resonances in Electron Clouds in a Positron Storage Ring

    SciTech Connect

    Pivi, M.T.F.; Ng, J.S.T.; Cooper, F.; Kharakh, D.; King, F.; Kirby, R.E.; Kuekan, B.; Spencer, Cherrill M.; Raubenheimer, T.O.; Wang, L.F.; /SLAC

    2011-08-24

    The first experimental observation of magnetic resonances in electron clouds is reported. The resonance was observed as a modulation in cloud intensity for uncoated as well as TiN-coated aluminum surfaces in the positron storage ring of the PEP-II collider at SLAC. Electron clouds frequently arise in accelerators of positively charged particles, and severely impact the machines performance. The TiN coating was found to be an effective remedy, reducing the cloud intensity by three orders of magnitude.

  14. Positron studies of metal-oxide-semiconductor structures

    SciTech Connect

    Au, H.L.; Asoka-Kumar, P.; Nielsen, B.; Lynn, K.G. )

    1993-03-15

    Positron annihilation spectroscopy provides a new probe to study the properties of interface traps in metal-oxide semiconductors (MOS). Using positrons, we have examined the behavior of the interface traps as a function of gate bias. We propose a simple model to explain the positron annihilation spectra from the interface region of a MOS capacitor.

  15. Physics perspectives at JLab with a polarized positron beam

    SciTech Connect

    Voutier, Eric J.-M.

    2014-06-01

    Polarized positron beams are in some respect mandatory complements to polarized electron beams. The advent of the PEPPo concept for polarized positron production opens the possibility for the developement at the Jefferson Laboratory of a continuous polarized positron beam. The benefits of such a beam for hadronic structure studies are discussed, together with the technical and technological challenges to face.

  16. Positron emission tomography - a new approach to brain chemistry

    SciTech Connect

    Jacobson, H.G.

    1988-11-11

    Positron emission tomography permits examination of the chemistry of the brain in living beings. Until recently, positron emission tomography had been considered a research tool, but it is rapidly moving into clinical practice. This report describes the uses and applications of positron emission tomography in examinations of patients with strokes, epilepsy, malignancies, dementias, and schizophrenia and in basic studies of synaptic neurotransmission.

  17. The multilayer Fe/Hf studied with slow positron beam

    NASA Astrophysics Data System (ADS)

    Murashige, Y.; Tashiro, M.; Nakajyo, T.; Koizumi, T.; Kanazawa, I.; Komori, F.; Ito, Y.

    1997-04-01

    The positron annihilation parameter versus the incident positron energy is measured in the thin Fe films and the Fe/Hf bilayer on silica substrate, by means of the variable energetic slow-positron beam technique. We have analyzed the change in open-volume spaces and vacancy-type defects among the Fe microcrystals in these thin films with the deposition temperature.

  18. Propagation of solitary waves in relativistic electron-positron-ion plasmas with kappa distributed electrons and positrons

    SciTech Connect

    Shah, Asif; Mahmood, S.; Haque, Q.

    2011-11-15

    Electrostatic ion acoustic solitary waves are studied in a plasma system comprising of relativistic ions, kappa distributed electrons, and positrons. The increase in the relativistic streaming factor and positron and electron kappa parameters cause the soliton amplitude to thrive. However, the soliton amplitude diminishes as the positron concentration is increased in the system. Our results are general and may be helpful, in understanding nonlinear phenomena in the presence of kappa distibuted electrons, positrons, and relativistically streaming ions.

  19. Positron Interactions with Atoms and Ions

    NASA Technical Reports Server (NTRS)

    Bhatia, Anand K.

    2012-01-01

    Dirac, in 1928, combining the ideas of quantum mechanics and the ideas of relativity invented the well-known relativistic wave equation. In his formulation, he predicted an antiparticle of the electron of spin n-bar/2. He thought that this particle must be a proton. Dirac published his interpretation in a paper 'A theory of electrons and protons.' It was shown later by the mathematician Hermann Weyl that the Dirac theory was completely symmetric between negative and positive particles and the positive particle must have the same mass as that of the electron. In his J. Robert Oppenheimer Memorial Prize Acceptance Speech, Dirac notes that 'Blackett was really the first person to obtain hard evidence for the existence of a positron but he was afraid to publish it. He wanted confirmation, he was really over cautious.' Positron, produced by the collision of cosmic rays in a cloud chamber, was detected experimentally by Anderson in 1932. His paper was published in Physical Review in 1933. The concept of the positron and its detection were the important discoveries of the 20th century. I have tried to discuss various processes involving interactions of positrons with atoms and ions. This includes scattering, bound states and resonances. It has not been possible to include the enormous work which has been carried out during the last 40 or 50 years in theory and measurements.

  20. Positron elastic scattering from alkaline earth targets

    NASA Astrophysics Data System (ADS)

    Poveda, Luis A.; Assafrão, Denise; Mohallem, José R.

    2016-07-01

    A previously reported model potential approach [Poveda et al., Phys. Rev. A 87, 052702 (2013)] was extended to study low energy positron elastic scattering from beryllium and magnesium. The cross sections were computed for energies ranging from 10-5 eV up to well above the positronium formation threshold. The present results are in good agreement with previous reports, including the prediction of a p-wave resonance in the cross section for magnesium. The emergence of this shape resonance is connected to a trend observed in the evolution of the partial wave cross section in going from Be to Mg target. This trend lead us to speculate that a sharp d-wave resonance should be observed in positron elastic scattering from calcium. The positron-target binding energies are investigated in detail, both using the scattering information and by direct computation of the bound state energies using the model potentials. Contribution to the Topical Issue "Advances in Positron and Electron Scattering", edited by Paulo Limao-Vieira, Gustavo Garcia, E. Krishnakumar, James Sullivan, Hajime Tanuma and Zoran Petrovic.Supplementary material in the form of one pdf file available from the Journal web page at http://dx.doi.org/10.1140/epjd/e2016-70120-y

  1. Resonances in Positron-molecule Interactions

    NASA Astrophysics Data System (ADS)

    Surko, C. M.

    2006-05-01

    The development of cold, trap-based beams has enabled high-resolution, energy-resolved studies of positron scattering and annihilation processes [1]. This talk focuses on three topics in this area. For hydrocarbon molecules such as alkanes (CnH2n+2), giant enhancements in annihilation rates are observed due to vibrational Feshbach resonances. The dependence of the rates on positron energy provides evidence that positrons bind to these molecules and a measure of the binding energies [1]. Recent results include evidence for a second, ``positronically excited'' bound state and new data for the methane series, CH3X, where X is a halogen. Other ``resonance-like features'' are sharp increases in the near-threshold electronic excitation cross sections for CO and N2 [2], and in the vibrational excitation cross sections for CO, CO2 and CH4 [3, 4]. Outstanding questions and the relationship of these observations to available theoretical predictions will be discussed.1. C. M. Surko, G. F. Gribakin, and S. J. Buckman, J. Phys. B 38, R57 (2005).2. J. P. Marler and C. M. Surko, Phys. Rev. A 72, 062713 (2005).3. J. P. Marler and C. M. Surko, Phys. Rev. A 72, 062702 (2005).4. J. P. Marler, G. F. Gribakin and C. M. Surko, Nuclear Instrum. and Meth. B, in press (2006).

  2. Positrons observed to originate from thunderstorms

    NASA Astrophysics Data System (ADS)

    Fishman, Gerald J.

    2011-05-01

    Thunderstorms are the result of warm, moist air moving rapidly upward, then cooling and condensing. Electrification occurs within thunderstorms (as noted by Benjamin Franklin), produced primarily by frictional processes among ice particles. This leads to lightning discharges; the types, intensities, and rates of these discharges vary greatly among thunderstorms. Even though scientists have been studying lightning since Franklin's time, new phenomena associated with thunderstorms are still being discovered. In particular, a recent finding by Briggs et al. [2011], based on observations by the Gamma-Ray Burst Monitor (GBM) instrument on NASA's satellite-based Fermi Gamma-ray Space Telescope (Fermi), shows that positrons are also generated by thunderstorms. Positrons are the antimatter form of electrons—they have the same mass and charge as an electron but are of positive rather than negative charge; hence the name positron. Observations of positrons from thunderstorms may lead to a new tool for understanding the electrification and high-energy processes occurring within thunderstorms. New theories, along with new observational techniques, are rapidly evolving in this field.

  3. Positron Annihilation in the Bipositronium Ps2

    SciTech Connect

    Bailey, David H.; Frolov, Alexei M.

    2005-07-01

    The electron-positron-pair annihilation in the bipositronium PS2 is considered. In particular, the two-, three-, one- and zero-photon annihilation rates are determined to high accuracy. The corresponding analytical expressions are also presented. Also, a large number of bound state properties have been determined for this system.

  4. Excitation of helium ion by positron impact

    SciTech Connect

    Khan, P.; Ghosh, A.S.

    1986-01-01

    Three (1s,2s,2p) and five (1s,2s,2p,3s-bar,3p-bar) -state close-coupling methods have been employed to calculate the n = 2 excitation cross sections of helium ion by positron impact. The effect of pseudostate is found to be very pronounced in the case of 1s-2s excitation.

  5. Progress Towards a Practical Multicell Positron Trap

    NASA Astrophysics Data System (ADS)

    Danielson, J. R.

    2013-10-01

    The physics and technology of positron confinement is central to a range of applications at the forefront of antimatter science. Progress in this area has been driven by the development of a suite of novel non-neutral plasma techniques whereby up to 4 ×109 positrons have now been trapped and stored. However the next generation of experiments will require orders of magnitude more positrons. This talk describes techniques to increase storage capacity to >=1012 using a novel multi-cell trap architecture. Plasmas will be stored in separate Penning-Malmberg traps (``cells'') arranged in parallel off the magnetic axis to maximize use of the magnetic field volume while minimizing the required confinement voltages. Experiments with electrons in a test structure will be described to explore the basic physics and technology of the multicell concept and to set the design of a 21-cell trap for 1012 positrons. Over 50% of a trapped plasma has been injected into an off-axis cell, and hour-long confinement of 2 ×108 particles has been achieved using rotating electric fields. Experiments are under way to identify the limits of the injection process and demonstrate confinement >1010 particles in a single off-axis cell using kilovolt confinement potentials. In collaboration with N. C. Hurst, C. J. Baker, and C. M. Surko. This work is supported by U.S. DTRA and the U.S. DOE/NSF plasma partnership.

  6. Positron Spectroscopy of Hydrothermally Grown Actinide Oxides

    DTIC Science & Technology

    2014-03-27

    In this method, the powdered material is placed in a solution which contains extremely powerful mineralizers, such as cesium fluoride for actinide...the isotope that acts as a positron source is sodium -22, which has a relatively short half-life (2.6 y) and emits a characteristic gamma photon (at

  7. Positron source position sensing detector and electronics

    DOEpatents

    Burnham, Charles A.; Bradshaw, Jr., John F.; Kaufman, David E.; Chesler, David A.; Brownell, Gordon L.

    1985-01-01

    A positron source, position sensing device, particularly with medical applications, in which positron induced gamma radiation is detected using a ring of stacked, individual scintillation crystals, a plurality of photodetectors, separated from the scintillation crystals by a light guide, and high resolution position interpolation electronics. Preferably the scintillation crystals are several times more numerous than the photodetectors with each crystal being responsible for a single scintillation event from a received gamma ray. The light guide will disperse the light emitted from gamma ray absorption over several photodetectors. Processing electronics for the output of the photodetectors resolves the location of the scintillation event to a fraction of the dimension of each photodetector. Because each positron absorption results in two 180.degree. oppositely traveling gamma rays, the detection of scintillation in pairs permits location of the positron source in a manner useful for diagnostic purposes. The processing electronics simultaneously responds to the outputs of the photodetectors to locate the scintillations to the source crystal. While it is preferable that the scintillation crystal include a plurality of stacked crystal elements, the resolving power of the processing electronics is also applicable to continuous crystal scintillators.

  8. Advanced Instrumentation for Positron Emission Tomography [PET

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  9. Advanced instrumentation for Positron Emission Tomography

    SciTech Connect

    Derenzo, S.E.; Budinger, T.F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underly modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost. 71 refs., 3 figs., 3 tabs.

  10. Positron and positronium interactions with Cu

    SciTech Connect

    Bromley, M.W.J.; Mitroy, J.

    2002-12-01

    The configuration-interaction (CI) method is used to investigate the interactions of positrons and positronium with copper at low energies. The calculations were performed within the framework of the fixed-core approximation with semiempirical polarization potentials used to model dynamical interactions between the active particles and the (1s-3d) core. Initially, calculations upon the e{sup +}Li system were used to refine the numerical procedures and highlighted the extreme difficulties of using an orthodox CI calculation to describe the e{sup +} Li system. The positron binding energy of e{sup +}Cu derived from a CI calculation which included electron and positron orbitals with l{<=}18 was 0.005 12 hartree while the spin-averaged annihilation rate was 0.507x10{sup 9} s{sup -1}. The configuration basis used for the bound-state calculation was also used as a part of the trial wave function for a Kohn variational calculation of positron-copper scattering. The positron-copper system has a scattering length of about 13.1a{sub 0} and the annihilation parameter Z{sub eff} at threshold was 72.9. The dipole polarizability of the neutral copper ground state was computed and found to be 41.6a{sub 0}{sup 3}. The structure of CuPs was also studied with the CI method and it was found to have a binding energy of 0.0143 hartree and an annihilation rate of {approx}2x10{sup 9} s{sup -1}.

  11. Positron annihilation studies of moisture in graphite-reinforced composites

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Holt, W. H.; Mock, W., Jr.; Buckingham, R. D.

    1980-01-01

    The positron lifetime technique of monitoring absorbed moisture is applied to several composites, including graphite/polymides which are candidates for high-temperature (over 260 C) applications. The experimental setup is a conventional fast-slow coincidence system wherein the positron lifetime is measured with respect to a reference time determined by the detection of a nuclear gamma ray emitted simultaneously with the positron. From the experiments, a rate of change of positron mean lifetime per unit mass of water can be determined for each type of specimen. Positron lifetime spectra are presented for a graphite/polyimide composite and for a pure polyimide.

  12. Relativistic Positron Creation Using Ultra-Intense Short Pulse Lasers

    SciTech Connect

    Chen, H; Wilks, S; Bonlie, J; Liang, E; Myatt, J; Price, D; Meyerhofer, D; Beiersdorfer, P

    2008-08-25

    We measure up to 2 x 10{sup 10} positrons per steradian ejected out the back of {approx}mm thick gold targets when illuminated with short ({approx} 1 ps) ultra-intense ({approx} 1 x 10{sup 20} W/cm{sup 2}) laser pulses. Positrons produced predominately by the Bethe-Heitler process and have an effective temperature of 2-4 MeV, with the distribution peaking at 4-7 MeV. The angular distribution of the positrons is anisotropic. The measurements indicate the laser produced, relativistic positron densities ({approx} 10{sup 16} positrons/cm{sup 3}) are the highest ever created in the laboratory.

  13. Relativistic Positron Creation Using Ultraintense Short Pulse Lasers

    SciTech Connect

    Chen Hui; Wilks, Scott C.; Bonlie, James D.; Price, Dwight F.; Beiersdorfer, Peter; Liang, Edison P.; Myatt, Jason; Meyerhofer, David D.

    2009-03-13

    We measure up to 2x10{sup 10} positrons per steradian ejected out the back of {approx}mm thick gold targets when illuminated with short ({approx}1 ps) ultraintense ({approx}1x10{sup 20} W/cm{sup 2}) laser pulses. Positrons are produced predominately by the Bethe-Heitler process and have an effective temperature of 2-4 MeV, with the distribution peaking at 4-7 MeV. The angular distribution of the positrons is anisotropic. Modeling based on the measurements indicate the positron density to be {approx}10{sup 16} positrons/cm{sup 3}, the highest ever created in the laboratory.

  14. Methods and apparatus for producing and storing positrons and protons

    DOEpatents

    Akers, Douglas W.

    2010-07-06

    Apparatus for producing and storing positrons may include a trap that defines an interior chamber therein and that contains an electric field and a magnetic field. The trap may further include a source material that includes atoms that, when activated by photon bombardment, become positron emitters to produce positrons. The trap may also include a moderator positioned adjacent the source material. A photon source is positioned adjacent the trap so that photons produced by the photon source bombard the source material to produce the positron emitters. Positrons from the positron emitters and moderated positrons from the moderator are confined within the interior chamber of the trap by the electric and magnetic fields. Apparatus for producing and storing protons are also disclosed.

  15. Optimization of positrons generation based on laser wakefield electron acceleration

    NASA Astrophysics Data System (ADS)

    Wu, Yuchi; Han, Dan; Zhang, Tiankui; Dong, Kegong; Zhu, Bin; Yan, Yonghong; Gu, Yuqiu

    2016-08-01

    Laser based positron represents a new particle source with short pulse duration and high charge density. Positron production based on laser wakefield electron acceleration (LWFA) has been investigated theoretically in this paper. Analytical expressions for positron spectra and yield have been obtained through a combination of LWFA and cascade shower theories. The maximum positron yield and corresponding converter thickness have been optimized as a function of driven laser power. Under the optimal condition, high energy (>100 MeV ) positron yield up to 5 ×1011 can be produced by high power femtosecond lasers at ELI-NP. The percentage of positrons shows that a quasineutral electron-positron jet can be generated by setting the converter thickness greater than 5 radiation lengths.

  16. Positron annihilation lifetime spectroscopy at a superconducting electron accelerator

    NASA Astrophysics Data System (ADS)

    Wagner, A.; Anwand, W.; Attallah, A. G.; Dornberg, G.; Elsayed, M.; Enke, D.; Hussein, A. E. M.; Krause-Rehberg, R.; Liedke, M. O.; Potzger, K.; Trinh, T. T.

    2017-01-01

    The Helmholtz-Zentrum Dresden-Rossendorf operates a superconducting linear accelerator for electrons with energies up to 35 MeV and average beam currents up to 1.6 mA. The electron beam is employed for production of several secondary beams including X-rays from bremsstrahlung production, neutrons, and positrons. The secondary positron beam after moderation feeds the Monoenergetic Positron Source (MePS) where positron annihilation lifetime (PALS) and positron annihilation Doppler-broadening experiments in materials science are performed in parallel. The adjustable repetition rate of the continuous-wave electron beams allows matching of the pulse separation to the positron lifetime in the sample under study. The energy of the positron beam can be set between 0.5 keV and 20 keV to perform depth resolved defect spectroscopy and porosity studies especially for thin films.

  17. High-yield positron systems for linear colliders

    SciTech Connect

    Clendenin, J.E.

    1989-04-01

    Linear colliders, such as the SLC, are among those accelerators for which a high-yield positron source operating at the repetition rate of the accelerator is desired. The SLC, having electron energies up to 50 GeV, presents the possibility of generating positron bunches with useful charge even exceeding that of the initial electron bunch. The exact positron yield to be obtained depends on the particular capture, transport and damping system employed. Using 31 GeV electrons impinging on a W-type converter phase-space at the target to the acceptance of the capture rf section, the SLC source is capable of producing, for every electron, up to two positrons within the acceptance of the positron damping ring. The design of this source and the performance of the positron system as built are described. Also, future prospects and limitations for high-yield positron systems are discussed. 11 refs., 5 figs., 3 tabs.

  18. Application of positron annihilation in materials science

    SciTech Connect

    Siegel, R.W.; Fluss, M.J.; Smedskjaer, L.C.

    1984-05-01

    Owing to the ability of the positron to annihilate from a variety of defect-trapped states, positron annihilation spectroscopy (PAS) has been applied increasingly to the characterization and study of defects in materials in recent years. In metals particularly, it has been demonstrated that PAS can yield defect-specific information which, by itself or in conjunction with more traditional experimental techniques, has already made a significant impact upon the determination of atomic-defect properties and the monitoring and characterization of vacancy-like microstructure development, as occurs during post-irradiation annealing. The applications of PAS are now actively expanding to the study of more complex defect-related phenomena in irradiated or deformed metals and alloys, phase transformations and structural disorder, surfaces and near-surface defect characterization. A number of these applications in materials science are reviewed and discussed with respect to profitable future directions.

  19. Experimental study of a crystal positron source

    NASA Astrophysics Data System (ADS)

    Chehab, R.; Cizeron, R.; Sylvia, C.; Baier, V.; Beloborodov, K.; Bukin, A.; Burdin, S.; Dimova, T.; Drozdetsky, A.; Druzhinin, V.; Dubrovin, M.; Golubev, V.; Serednyakov, S.; Shary, V.; Strakhovenko, V.; Artru, X.; Chevallier, M.; Dauvergne, D.; Kirsch, R.; Lautesse, Ph.; Poizat, J.-C.; Remillieux, J.; Jejcic, A.; Keppler, P.; Major, J.; Gatignon, L.; Bochek, G.; Kulibaba, V.; Maslov, N.; Bogdanov, A.; Potylitsin, A.; Vnukov, I.

    2002-01-01

    Tungsten crystals oriented on their <111> axis, were submitted to 6 and 10 GeV electron beams on the SPS-CERN transfer lines. The crystals, 4 and 8 mm thick, used alone or associated to 4 mm thick amorphous disk, were studied as positron sources. The emerging positrons were detected by a Drift Chamber partially immersed in a magnetic field, where their trajectories were reconstructed providing the energy spectrum and the angular distribution. Significant enhancements were observed for the crystal source when compared to the amorphous one of the same thickness. The gain was larger than 3 and 2 for the 4 mm and 8 mm targets, respectively. The presented results look very promising for e+e- linear colliders.

  20. Positron Emission Tomography Imaging of Hypoxia

    PubMed Central

    Lapi, Suzanne E.; Voller, Thomas F.; Welch, Michael J.

    2009-01-01

    Synopsis Hypoxia imaging has applications in functional recovery in ischemic events such as stroke and myocardial ischemia, but especially in tumors in which hypoxia can be predictive of treatment response and overall prognosis. Recently there has been development of imaging agents utilizing positron emission tomography for non-invasive imaging of hypoxia. Many of these PET agents have come to the forefront of hypoxia imaging. Halogenated PET nitroimidazole imaging agents labeled with 18F (t1/2 = 110 m) and 124I (t1/2 = 110 m) have been under investigation for the last 25 years, with radiometal agents (64Cu-ATSM) being developed more recently. This review focuses on these positron emission tomography imaging agents for hypoxia. PMID:20046923

  1. Positron scattering and annihilation from hydrogenlike ions

    SciTech Connect

    Novikov, S.A.; Bromley, M.W.J.; Mitroy, J.

    2004-05-01

    The Kohn variational method is used with a configuration-interaction-type wave function to determine the J=0 and J=1 phase shifts and annihilation parameter Z{sub eff} for positron-hydrogenic ion scattering. The phase shifts are within 1-2% of the best previous calculations. The values of Z{sub eff} are small and do not exceed unity for any of the momenta considered. At thermal energies Z{sub eff} is minute with a value of order 10{sup -50} occurring for He{sup +} at k=0.05a{sub 0}{sup -1}. In addition to the variational calculations, analytic expressions for the phase shift and annihilation parameters within the Coulomb wave Born approximation are derived and used to help elucidate the dynamics of positron collisions with positive ions.

  2. Cold Positrons from Decaying Dark Matter

    SciTech Connect

    Boubekeur, Lotfi; Dodelson, Scott; Vives, Oscar

    2012-11-01

    Many models of dark matter contain more than one new particle beyond those in the Standard Model. Often heavier particles decay into the lightest dark matter particle as the Universe evolves. Here we explore the possibilities that arise if one of the products in a (Heavy Particle) $\\rightarrow$ (Dark Matter) decay is a positron, and the lifetime is shorter than the age of the Universe. The positrons cool down by scattering off the cosmic microwave background and eventually annihilate when they fall into Galactic potential wells. The resulting 511 keV flux not only places constraints on this class of models but might even be consistent with that observed by the INTEGRAL satellite.

  3. Positron spectroscopy of 2D materials using an advanced high intensity positron beam

    NASA Astrophysics Data System (ADS)

    McDonald, A.; Chirayath, V.; Lim, Z.; Gladen, R.; Chrysler, M.; Fairchild, A.; Koymen, A.; Weiss, A.

    An advanced high intensity variable energy positron beam(~1eV to 20keV) has been designed, tested and utilized for the first coincidence Doppler broadening (CDB) measurements on 6-8 layers graphene on polycrystalline Cu sample. The system is capable of simultaneous Positron annihilation induced Auger electron Spectroscopy (PAES) and CDB measurements giving it unparalleled sensitivity to chemical structure at external surfaces, interfaces and internal pore surfaces. The system has a 3m flight path up to a micro channel plate (MCP) for the Auger electrons emitted from the sample. This gives a superior energy resolution for PAES. A solid rare gas(Neon) moderator was used for the generation of the monoenergetic positron beam. The positrons were successfully transported to the sample chamber using axial magnetic field generated with a series of Helmholtz coils. We will discuss the PAES and coincidence Doppler broadening measurements on graphene -Cu sample and present an analysis of the gamma spectra which indicates that a fraction of the positrons implanted at energies 7-60eV can become trapped at the graphene/metal interface. This work was supported by NSF Grant No. DMR 1508719 and DMR 1338130.

  4. Dipole configuration for confinement of positrons and electron-positron plasma

    NASA Astrophysics Data System (ADS)

    Stenson, E. V.; Saitoh, H.; Horn-Stanja, J.; Hergenhahn, U.; Paschkowski, N.; Sunn Pedersen, T.; Stoneking, M. R.; Dickmann, M.; Singer, M.; Vohburger, S.; Hugenschmidt, C.; Schweikhard, L.; Danielson, J. R.; Surko, C. M.

    2016-10-01

    Laboratory creation and confinement of electron-positron plasmas, which are expected to exhibit atypical plasma physics characteristics, would enable tests of many theory and simulation predictions (e.g., the stabilization of anomalous transport mechanisms). This is the goal of APEX/PAX (A Positron-Electron eXperiment/Positron Accumulation eXperiment). Following demonstration of efficient (38%) E ×B injection and subsequent confinement (τ = 3-5 ms) of cold positrons in a dipole magnetic field, the system is undergoing upgrades from a supported permanent magnet to a supported HTSC (high-temperature superconductor) coil, then to a levitated HTSC coil suitable for the simultaneous confinement of electrons and positrons. This contribution will report on the design and testing of the new systems and subsystems (e.g., for cooling, excitation, and levitation) and, if available, on results of upcoming experiments using a ``rotating wall'' to generate inward particle flux deeper into the confinement region. on behalf of the APEX/PAX team and collaborators.

  5. Positrons for Antihydrogen with ATRAP: efficient transfer of large positron numbers

    NASA Astrophysics Data System (ADS)

    Storry, Cody; Comeau, Daniel; Dror, Asaf; Fitzakerley, Daniel; George, Matthew; Hessels, Eric; Weel, Matthew

    2012-06-01

    Positrons accumulated in a room-temperature buffer-gas-cooled positron accumulator are efficiently transferred into a superconducting solenoid which houses the ATRAP cryogenic Penning trap for antihydrogen research. The positrons are guided along a 9-meter-long magnetic guide which connects the central field lines of the 0.15-tesla field in the positron accumulator to central magnetic field lines of the superconducting solenoid. Seventy independently-controllable electromagnets are required to overcome the fringing field of the large-bore superconducting solenoid. The guide includes both a 15 degree upward bend and a 105 degree downward bend to account for the orthogonal orientation of the accumulator with respect to the cryogenic Penning trap. Low-energy positrons ejected from the accumulator follow the magnetic field lines within the guide and are transferred into the superconducting solenoid with nearly 100% efficiency. 7 meters of 5-cm-diameter stainless-steel tube, and a 20-mm-long, 1.5-mm-diameter cryogenic pumping restriction ensure that the 10-2 mbar pressure in the accumulator is well isolated from the extreme vacuum required in the Penning trap to allow long antimatter storage times.

  6. Positron-inert gas differential elastic scattering

    NASA Technical Reports Server (NTRS)

    Kauppila, W. E.; Smith, Steven J.; Kwan, C. K.; Stein, T. S.

    1990-01-01

    Measurements are being made in a crossed beam experiment of the relative elastic differential cross section (DCS) for 5 to 300 eV positrons scattering from inert gas atoms (He, Ne, Ar, Kr, and Xe) in the angular range from 30 to 134 deg. Results obtained at energies around the positronium (Ps) formation threshold provide evidence that Ps formation and possibly other inelastic channels have an effect on the elastic scattering channel.

  7. Imaging Prostate Cancer with Positron Emission Tomography

    DTIC Science & Technology

    2014-07-01

    AD_________________ Award Number: W81XWH-13-1-0125 TITLE: Imaging Prostate Cancer with Positron Emission Tomography...ABOVE ADDRESS. 1. REPORT DATE 2014 2. REPORT TYPE Annual 3. DATES COVERED 01 Sept 2013-31 Aug 2014 4. TITLE AND SUBTITLE Imaging Prostate Cancer ...proposal is to develop peptide based radiopharmaceuticals and evaluate them as PET imaging agents in preclinical animal models of prostate cancer

  8. Cosmic-ray Positrons from Millisecond Pulsars

    NASA Astrophysics Data System (ADS)

    Venter, C.; Kopp, A.; Harding, A. K.; Gonthier, P. L.; Büsching, I.

    2015-07-01

    Observations by the Fermi Large Area Telescope of γ-ray millisecond pulsar (MSP) light curves imply copious pair production in their magnetospheres, and not exclusively in those of younger pulsars. Such pair cascades may be a primary source of Galactic electrons and positrons, contributing to the observed enhancement in positron flux above ∼10 GeV. Fermi has also uncovered many new MSPs, impacting Galactic stellar population models. We investigate the contribution of Galactic MSPs to the flux of terrestrial cosmic-ray electrons and positrons. Our population synthesis code predicts the source properties of present-day MSPs. We simulate their pair spectra invoking an offset-dipole magnetic field. We also consider positrons and electrons that have been further accelerated to energies of several TeV by strong intrabinary shocks in black widow (BW) and redback (RB) systems. Since MSPs are not surrounded by pulsar wind nebulae or supernova shells, we assume that the pairs freely escape and undergo losses only in the intergalactic medium. We compute the transported pair spectra at Earth, following their diffusion and energy loss through the Galaxy. The predicted particle flux increases for non-zero offsets of the magnetic polar caps. Pair cascades from the magnetospheres of MSPs are only modest contributors around a few tens of GeV to the lepton fluxes measured by the Alpha Magnetic Spectrometer, PAMELA, and Fermi, after which this component cuts off. The contribution by BWs and RBs may, however, reach levels of a few tens of percent at tens of TeV, depending on model parameters.

  9. COSMIC-RAY POSITRONS FROM MILLISECOND PULSARS

    SciTech Connect

    Venter, C.; Kopp, A.; Büsching, I.; Harding, A. K.; Gonthier, P. L.

    2015-07-10

    Observations by the Fermi Large Area Telescope of γ-ray millisecond pulsar (MSP) light curves imply copious pair production in their magnetospheres, and not exclusively in those of younger pulsars. Such pair cascades may be a primary source of Galactic electrons and positrons, contributing to the observed enhancement in positron flux above ∼10 GeV. Fermi has also uncovered many new MSPs, impacting Galactic stellar population models. We investigate the contribution of Galactic MSPs to the flux of terrestrial cosmic-ray electrons and positrons. Our population synthesis code predicts the source properties of present-day MSPs. We simulate their pair spectra invoking an offset-dipole magnetic field. We also consider positrons and electrons that have been further accelerated to energies of several TeV by strong intrabinary shocks in black widow (BW) and redback (RB) systems. Since MSPs are not surrounded by pulsar wind nebulae or supernova shells, we assume that the pairs freely escape and undergo losses only in the intergalactic medium. We compute the transported pair spectra at Earth, following their diffusion and energy loss through the Galaxy. The predicted particle flux increases for non-zero offsets of the magnetic polar caps. Pair cascades from the magnetospheres of MSPs are only modest contributors around a few tens of GeV to the lepton fluxes measured by the Alpha Magnetic Spectrometer, PAMELA, and Fermi, after which this component cuts off. The contribution by BWs and RBs may, however, reach levels of a few tens of percent at tens of TeV, depending on model parameters.

  10. Positron annihilation study of P implanted Si

    SciTech Connect

    Asoka-Kumar, P.; Au, H.L.; Lynn, K.G. ); Sferlazzo, P. . SED Division)

    1992-01-01

    High-energy ion implantation (above 200 keV) is now commonly used in a variety of VLSI processes. The high energy required for these implants is often achieved by implanting multiply charged ions, which inevitably brings in the problem of low-energy ion contamination. The low-energy contamination is difficult to diagnose and detect. Positron annihilation spectroscopy is used to examine the defect distributions in these high energy implants with varying degrees of contamination.

  11. Positron annihilation study of P implanted Si

    SciTech Connect

    Asoka-Kumar, P.; Au, H.L.; Lynn, K.G.; Sferlazzo, P.

    1992-12-01

    High-energy ion implantation (above 200 keV) is now commonly used in a variety of VLSI processes. The high energy required for these implants is often achieved by implanting multiply charged ions, which inevitably brings in the problem of low-energy ion contamination. The low-energy contamination is difficult to diagnose and detect. Positron annihilation spectroscopy is used to examine the defect distributions in these high energy implants with varying degrees of contamination.

  12. The Clic Electron and Positron Polarized Sources

    NASA Astrophysics Data System (ADS)

    Rinolfi, L.

    2011-01-01

    The CLIC polarized electron source is based on a DC gun where the photocathode is illuminated by a laser beam. Each micro-bunch has a charge of 6 × 109 e-, a width of 100 ps and a repetition rate of 2 GHz. A peak current of 10 A in the micro-bunch is a challenge for the surface charge limit of the photo-cathode. Two options are feasible to generate the 2 GHz e- bunch train: 100 ps micro-bunches can be extracted from the photo-cathode either by a 2 GHz laser system or by generating a macro-bunch using a ~200 ns laser pulse and a subsequent RF bunching system to produce the appropriate micro-bunch structure. Recent results obtained by SLAC, for the latter case, are presented. The polarized positron source is based on a positron production scheme in which polarized photons are produced by a laser Compton scattering process. The resulting circularly-polarized gamma photons are sent onto a target, producing pairs of longitudinally polarized electrons and positrons. The Compton backscattering process occurs either in a Compton ring, where a 1 GeV electron beam interacts with circularly-polarized photons in an optical resonator or in a 1.8 GeV Compton Energy Recovery Linac (ERL) or in a 6 GeV Linac with several optical cavities. The undulator scheme is also studied. The nominal CLIC e+ bunch population is 6.7 × 109 particles per bunch at 200 MeV. The tradeoff between e+ yield and level of polarization is an important topic. The overall scheme for both polarized electron and positron beams is described.

  13. Positron annihilation in superconducting 123 compounds

    SciTech Connect

    Peter, M.; Manuel, A.A.; Erb, A. . Dept. of Physics of Condensed Matter)

    1998-12-20

    After a brief review of the theory of angular correlation of positron annihilation radiation (ACAR), the authors illustrate experimental principles and give examples of successful determination of electron momentum density (EMD) and of positron lifetime in solids. The central question which the authors try to answer concerns the contribution of positron spectroscopy to the knowledge and understanding of the new high temperature superconducting oxides. They find that in these oxides also, partially filled bands exist and they can observe parts of their Fermi surface and measure lifetimes in accordance with band theoretical calculations. There are characteristic differences, however. The intensity of the anisotropy of the ACAR signal is below theoretical expectation and signals depend on sample preparation. Recent studies by the Geneva group have concerned dependence of the signals on impurities, on oxygen content and on the thermal history of preparation. Of particular interest are correlations between the variations of these signals and between the variations of structural and transport properties in these substances. Besides deliberate additions of impurities, the Geneva group also reports progress in the preparations of samples of highest purity (barium zirconate crucibles). The alloy series Pr[sub x]Y[sub 1[minus]x]Ba[sub 2]Cu[sub 3]O[sub 7[minus][delta

  14. Feasibility study for positron emission mammography.

    PubMed

    Thompson, C J; Murthy, K; Weinberg, I N; Mako, F

    1994-04-01

    A feasibility study is presented for a small, low-cost, dedicated device for positron emission mammography. Two detector arrays above and below the breast would be placed in a conventional mammography unit. These detectors are sensitive to positron annihilation radiation, and are connected to a coincidence circuit and a multiplane image memory. Images of the distribution of positron-emitting isotope are obtained in real time by incrementing the memory location at the intersection of each line of response. Monte Carlo simulations of a breast phantom are compared with actual scans of this phantom in a conventional PET scanner. The simulations and experimental data are used to predict the performance of the proposed system. Spatial resolution experiments using very narrow bismuth germanate BGO crystals suggest that spatial resolutions of about 2 mm should be possible. The efficiency of the proposed device is about ten times that of a conventional brain scanner. The scatter fraction is greater, but the scattered radiation has a very flat distribution. By designing the device to fit in an existing mammography unit, conventional mammograms can be taken after the injection of the radio-pharmaceutical allowing exact registration of the emission and conventional mammographic images.

  15. New generation electron-positron factories

    NASA Astrophysics Data System (ADS)

    Zobov, Mikhail

    2011-09-01

    In 2010 we celebrate 50 years since commissioning of the first particle storage ring ADA in Frascati (Italy) that also became the first electron-positron collider in 1964. After that date the particle colliders have increased their intensity, luminosity and energy by several orders of magnitude. Namely, because of the high stored beam currents and high rate of useful physics events (luminosity) the modern electron-positron colliders are called "factories". However, the fundamental physics has required luminosities by 1-2 orders of magnitudes higher with respect to those presently achieved. This task can be accomplished by designing a new generation of factories exploiting the potential of a new collision scheme based on the Crab Waist (CW) collision concept recently proposed and successfully tested at Frascati. In this paper we discuss the performance and limitations of the present generation electron-positron factories and give a brief overview of new ideas and collision schemes proposed for further collider luminosity increase. In more detail we describe the CW collision concept and the results of the crab waist collision tests in DAϕNE, the Italian ϕ-factory. Finally, we briefly describe most advanced projects of the next generation factories based on the CW concept: SuperB in Italy, SuperKEKB in Japan and SuperC-Tau in Russia.

  16. Advances in positron and electron scattering*

    NASA Astrophysics Data System (ADS)

    Limão-Vieira, Paulo; García, Gustavo; Krishnakumar, E.; Petrović, Zoran; Sullivan, James; Tanuma, Hajime

    2016-10-01

    The topical issue on Advances in Positron and Electron Scattering" combines contributions from POSMOL 2015 together with others devoted to celebrate the unprecedented scientific careers of our loyal colleagues and trusted friends Steve Buckman (Australian National University, Australia) and Michael Allan (University of Fribourg, Switzerland) on the occasion of their retirements. POSMOL 2015, the XVIII International Workshop on Low-Energy Positron and Positronium Physics and the XIX International Symposium on Electron-Molecule Collisions and Swarms, was held at Universidade NOVA de Lisboa, Lisboa, Portugal, from 17-20 July 2015. The international workshop and symposium allowed to achieve a very privileged forum of sharing and developing our scientific expertise on current aspects of positron, positronium and antiproton interactions with electrons, atoms, molecules and solid surfaces, and related topics, as well as electron interactions with molecules in both gaseous and condensed phases. Particular topics include studies of electron interactions with biomolecules, electron induced surface chemistry and the study of plasma processes. Recent developments in the study of swarms are also fully addressed.

  17. High-field capture section for SLC positron source

    SciTech Connect

    Hoag, H.A.; Deruyter, H.; Kramer, J.; Yao, C.G.

    1986-05-01

    The positron source for SLC is being installed at the two-thirds point on the SLAC linac. Electron bunches at 33 GeV impinge upon a Tantalum/Tungsten target, producing showers of positrons with energies extending from approximately 2 to 20 MeV, with most positrons at the low end of this range. Positrons with low energies and finite transverse momenta slip phase during the processes of reacceleration and reinjection into the SLC system, increasing the energy spread and reducing the overall yield of the positron source. This reduction in yield has to be minimized by ''capturing'' the positrons with a high-field accelerator section placed as soon after the target as possible. The design, fabrication and RF testing of this accelerator section are described.

  18. A General Quantum Mechanical Method to Predict Positron Spectroscopy

    DTIC Science & Technology

    2007-06-01

    70 6.2.3 Positronic Systems for Modeling and Experiment 71 Appendix A. Electron-Positron Annihilation Observables from NEO-HF and NEO-MP2...spectroscopy (PAS) experiments are widely used to study materials defects, including point defects in semiconductors and voids in composite materials...addition to traditional PAS techniques, experiments involving VFRs are also discussed. In Section 2.2, methods for modeling positron interaction with

  19. Positron Annihilation Studies In Polymer Nano-Composites

    SciTech Connect

    Chen, H. M.; Awad, Somia; Jean, Y. C.; Yang, J.; Lee, L. James

    2011-06-01

    Positron annihilation spectroscopy coupled with a variable mono-energy positron beam has been applied to study nanoscale polymeric nanocomposites. New information about multilayer depth profiles and structures, interfacial free-volume and open space properties have been obtained in polystyrene/carbon nano fiber composites. The S parameter in Doppler Broadening Energy Spectra combined slow positron beam is used to quantitatively represent the free volume, open spaces, and interactions in the interface between polystyrene matrix and carbon nanofibers.

  20. Detecting positron-atom bound states through resonant annihilation.

    PubMed

    Dzuba, V A; Flambaum, V V; Gribakin, G F

    2010-11-12

    A method is proposed for detecting positron-atom bound states by observing enhanced positron annihilation due to electronic Feshbach resonances at electron-volt energies. The method is applicable to a range of open-shell transition-metal atoms which are likely to bind the positron: Fe, Co, Ni, Tc, Ru, Rh, Sn, Sb, Ta, W, Os, Ir, and Pt. Estimates of their binding energies are provided.

  1. On the localization of positrons in metal vacancies

    NASA Astrophysics Data System (ADS)

    Babich, A. V.; Pogosov, V. V.; Reva, V. I.

    2015-11-01

    The probability of localization of positrons in single vacancies of Al, Cu, and Zn as a function of temperature has been calculated. Vacancy has been simulated by a cavity with a radius of the Wigner-Seitz cell in the stabilized jellium model. A formula for the rate of trapping of a positron by a vacancy as a function of the positron energy has been obtained using the "golden" rule for transitions under the assumption that the positron energy is spent on excitation of electron-hole pairs. The temperature dependence of the localization rate has been calculated for thermalized positrons. It has been found that, in the vicinity of the triple point, the localization rate is close in order of magnitude to the annihilation rate. Based on the results reported in our previous publications devoted to the evaluation of the influence of vacancies on the work function of free positrons, it has been assumed that, near the surface of the metal, there are vacancies charged by positrons. In the approximation of a two-dimensional superlattice, the near-surface vacancy barrier has been estimated. The experimentally revealed shift of the energy distribution of re-emitted positrons has been assumed to be caused by the reflection of low-energy positrons from the vacancy barrier back into the bulk of the metal where they annihilate.

  2. Sensitivity of positron annihilation to hydrogen in Zr

    SciTech Connect

    Hood, G.M.; Schultz, R.J.

    1982-01-01

    Positron annihilation spectroscopy has been applied to the quantitative determination of hydrogen in zirconium. The sensitivity of the positron annihilation was noted to be influenced not only by the presence of hydrogen but also by the heat treatment of the hydrided samples. The positron is attracted to the relatively negative, or ion-core-deficient regions of the metal, F regions commonly associated with vacancies, voids and dislocations. It was found to be very difficult to gauge the relative effects which hydrides and dislocations might have on the positron annihilation in zirconium. (BLM)

  3. Positron-molecule bound states and positive ion production

    NASA Technical Reports Server (NTRS)

    Leventhal, M.; Passner, A.; Surko, C. M.

    1990-01-01

    The interaction was studied of low energy positrons with large molecules such as alkanes. These data provide evidencce for the existence of long lived resonances and bound states of positrons with neutral molecules. The formation process and the nature of these resonances are discussed. The positive ions produced when a positron annihilates with an electron in one of these resonances were observed and this positive ion formation process is discussed. A review is presented of the current state of the understanding of these positron-molecule resonances and the resulting positive ion formation. A number of outstanding issues in this area is also discussed.

  4. What is the fate of runaway positrons in tokamaks?

    DOE PAGES

    Liu, Jian; Qin, Hong; Fisch, Nathaniel J.; ...

    2014-06-19

    In this study, massive runaway positrons are generated by runaway electrons in tokamaks. The fate of these positrons encodes valuable information about the runaway dynamics. The phase space dynamics of a runaway position is investigated using a Lagrangian that incorporates the tokamak geometry, loop voltage, radiation and collisional effects. It is found numerically that runaway positrons will drift out of the plasma to annihilate on the first wall, with an in-plasma annihilation possibility less than 0.1%. The dynamics of runaway positrons provides signatures that can be observed as diagnostic tools.

  5. Search for a positron anisotropy with PAMELA experiment

    NASA Astrophysics Data System (ADS)

    Panico, B.; Adriani, O.; Barbarino, G. C.; Bazilevskaya, G. A.; Bellotti, R.; Boezio, M.; Bogomolov, E. A.; Bongi, M.; Bonvicini, V.; Bottai, S.; Bruno, A.; Cafagna, F.; Campana, D.; Carlson, P.; Casolino, M.; Castellini, G.; De Donato, C.; De Santis, C.; De Simone, N.; Di Felice, V.; Formato, V.; Galper, A. M.; Giaccari, U.; Karelin, A. V.; Koldashov, S. V.; Koldobskiy, S.; Krutkov, S. Y.; Kvashnin, A. N.; Leonov, A.; Malakhov, V.; Marcelli, L.; Martucci, M.; Mayorov, A. G.; Menn, W.; Mergé, M.; Mikhailov, V. V.; Mocchiutti, E.; Monaco, A.; Mori, N.; Munini, R.; Osteria, G.; Palma, F.; Pearce, M.; Picozza, P.; Ricci, M.; Ricciarini, S. B.; Sarkar, R.; Scotti, V.; Simon, M.; Sparvoli, R.; Spillantini, P.; Stozhkov, Y. I.; Vacchi, A.; Vannuccini, E.; Vasilyev, G. I.; Voronov, S. A.; Yurkin, Y. T.; Zampa, G.; Zampa, N.

    2015-09-01

    The PAMELA experiment has been collecting data since 2006; its results indicate a rise in the positron fraction with respect to the sum of electrons and positrons in the cosmic-ray (CR) spectrum above 10 GeV. This excess can be due to additional sources, as SNRs or pulsars, which can lead to an anisotropy in the local CR positron, detectable from current experiments. We report on the analysis on spatial distributions of positron events collected by PAMELA, taking into account also the geomagnetic field effects. No significant deviation from the isotropy has been observed.

  6. Recent Developments in the Design of the NLC Positron Source

    SciTech Connect

    Kotseroglou, T.; Bharadwaj, V.; Clendenin, J.E.; Ecklund, S,; Frisch, J.; Krejcik, P,; Kukikov, A.V.; Liu, J.; Maruyama, T.; Millage, K.K.; Mulhollan, G.; Nelson, W.R.; Schultz, D.C.; Sheppard, J.C.; Turner, J.; Van Bibber, K.; Flottmann, K.; Namito, Y.

    1999-11-05

    Recent developments in the design of the Next Linear Collider (NLC) positron source based on updated beam parameters are described. The unpolarized NLC positron source [1,2] consists of a dedicated 6.2 GeV S-band electron accelerator, a high-Z positron production target, a capture system and an L-band positron linac. The 1998 failure of the SLC target, which is currently under investigation, may lead to a variation of the target design. Progress towards a polarized positron source is also presented. A moderately polarized positron beam colliding with a highly polarized electron beam results in an effective polarization large enough to explore new physics at NLC. One of the schemes towards a polarized positron source incorporates a polarized electron source, a 50 MeV electron accelerator, a thin target for positron production and a new capture system optimized for high-energy, small angular-divergence positrons. The yield for such a process, checked using the EGS4 code, is of the order of 10{sup -3}. The EGS4 code has being enhanced to include the effect of polarization in bremsstrahlung and pair-production process.

  7. Probing the positron moderation process using high-intensity, highly polarized slow-positron beams

    NASA Technical Reports Server (NTRS)

    Van House, J.; Zitzewitz, P. W.

    1984-01-01

    A highly polarized (P = 0.48 + or - 0.02) intense (500,000/sec) beam of 'slow' (Delta E = about 2 eV) positrons (e+) is generated, and it is shown that it is possible to achieve polarization as high as P = 0.69 + or - 0.04 with reduced intensity. The measured polarization of the slow e+ emitted by five different positron moderators showed no dependence on the moderator atomic number (Z). It is concluded that only source positrons with final kinetic energy below 17 keV contribute to the slow-e+ beam, in disagreement with recent yield functions derived from low-energy measurements. Measurements of polarization and yield with absorbers of different Z between the source and moderator show the effects of the energy and angular distributions of the source positrons on P. The depolarization of fast e+ transmitted through high-Z absorbers has been measured. Applications of polarized slow-e+ beams are discussed.

  8. Positron impact ionization of atomic hydrogen

    SciTech Connect

    Acacia, P.; Campeanu, R.I.; Horbatsch, M.

    1993-05-01

    We will present integrated cross sections for ionization of atomic hydrogen by positrons. These have been calculated in a distorted-wave approximation using energy-dependent effective charges in the final channel as well as static and polarization potentials in the initial channel. We present two models for calculating the energy-dependent effective charges both of which produce results in good agreement with the recent experimental measurements of Spicher et al. This is in contrast to previous distorted-wave calculations which used fixed effective charges as well as classical trajectory calculations. Both of these latter methods produced results which were substantially below ours and the experimental data.

  9. Possible resonance in positron-lithium scattering

    NASA Astrophysics Data System (ADS)

    Abdel-Raouf, M. A.; Wood, R. F.

    1990-09-01

    The possible appearance of resonances in the partial cross sections of the inelastic collisions of positrons with lithium atoms at energies below 5 eV is investigated. It is assumed that only elastic and rearrangement channels are open, while excitation channels are closed. A coupled static formalism, in which the polarization potentials of the lithium and positronium are switched on, is employed. The basis set of Clementi and Roetti [At. Data Nucl. Data Tables 14, 177 (1974)] is used for describing the target model. Comparison between the resulting total cross sections and those obtained by other authors is presented.

  10. Positron autoradiography for intravascular imaging: feasibility evaluation.

    PubMed

    Shikhaliev, Polad M; Xu, Tong; Ducote, Justin L; Easwaramoorthy, Balasubramaniam; Mukherjee, Jogeshwar; Molloi, Sabee

    2006-02-21

    Approximately 70% of acute coronary artery disease is caused by unstable (vulnerable) plaques with an inflammation of the overlying cap and high lipid content. A rupturing of the inflamed cap of the plaque results in propagation of the thrombus into the lumen, blockage of the artery and acute ischaemic syndrome or sudden death. Morphological imaging such as angiography or intravascular ultrasound cannot determine inflammation status of the plaque. A radiotracer such as 18F-FDG is accumulated in vulnerable plaques due to higher metabolic activity of the inflamed cap and could be used to detect a vulnerable plaque. However, positron emission tomography (PET) cannot detect the FDG-labelled plaques because of respiratory and heart motions, small size and low activity of the plaques. Plaques can be detected using a miniature particle (positron) detector inserted into the artery. In this work, a new detector concept is investigated for intravascular imaging of the plaques. The detector consists of a storage phosphor tip bound to the end of an intravascular catheter. It can be inserted into an artery, absorb the 18F-FDG positrons from the plaques, withdrawn from the artery and read out. Length and diameter of the storage phosphor tip can be matched to the length and the diameter of the artery. Monte Carlo simulations and experimental evaluations of coronary plaque imaging with the proposed detector were performed. It was shown that the sensitivity of the storage phosphor detector to the positrons of 18F-FDG is sufficient to detect coronary plaques with 1 mm and 2 mm sizes and 590 Bq and 1180 Bq activities in the arteries with 2 mm and 3 mm diameters, respectively. An experimental study was performed using plastic tubes with 2 mm diameter filled with an FDG solution, which simulates blood. FDG spots simulating plaques were placed over the surface of the tube. A phosphor tip was inserted into the tube and imaged the plaques. Exposure time was 1 min in all simulations and

  11. Positron emission tomography (PET) for cholangiocarcinoma

    PubMed Central

    Breitenstein, S.; Apestegui, C.

    2008-01-01

    The combination of positron emission tomography (PET) with computed tomography (PET-CT) provides simultaneous metabolic and anatomic information on tumors in the same imaging session. Sensitivity of PET/PET-CT is higher for intrahepatic (>90%) than for extrahepatic cholangiocarcinoma (CCA) (about 60%). The detection rate of distant metastasis is 100%. PET, and particularly PET-CT, improves the results and impacts on the oncological management in CCA compared with other imaging modalities. Therefore, PET-CT is recommended in the preoperative staging of intrahepatic (strength of recommendation: moderate) and extrahepatic (strength of recommendation: low) CCA. PMID:18773069

  12. DHCAL with minimal absorber: measurements with positrons

    NASA Astrophysics Data System (ADS)

    Freund, B.; Neubüser, C.; Repond, J.; Schlereth, J.; Xia, L.; Dotti, A.; Grefe, C.; Ivantchenko, V.; Berenguer Antequera, J.; Calvo Alamillo, E.; Fouz, M.-C.; Marin, J.; Puerta-Pelayo, J.; Verdugo, A.; Brianne, E.; Ebrahimi, A.; Gadow, K.; Göttlicher, P.; Günter, C.; Hartbrich, O.; Hermberg, B.; Irles, A.; Krivan, F.; Krüger, K.; Kvasnicka, J.; Lu, S.; Lutz, B.; Morgunov, V.; Provenza, A.; Reinecke, M.; Sefkow, F.; Schuwalow, S.; Tran, H. L.; Garutti, E.; Laurien, S.; Matysek, M.; Ramilli, M.; Schroeder, S.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kovalcuk, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; van Doren, B.; Wilson, G. W.; Kawagoe, K.; Hirai, H.; Sudo, Y.; Suehara, T.; Sumida, H.; Takada, S.; Tomita, T.; Yoshioka, T.; Bilokin, S.; Bonis, J.; Cornebise, P.; Pöschl, R.; Richard, F.; Thiebault, A.; Zerwas, D.; Hostachy, J.-Y.; Morin, L.; Besson, D.; Chadeeva, M.; Danilov, M.; Markin, O.; Popova, E.; Gabriel, M.; Goecke, P.; Kiesling, C.; van der Kolk, N.; Simon, F.; Szalay, M.; Corriveau, F.; Blazey, G. C.; Dyshkant, A.; Francis, K.; Zutshi, V.; Kotera, K.; Ono, H.; Takeshita, T.; Ieki, S.; Kamiya, Y.; Ootani, W.; Shibata, N.; Jeans, D.; Komamiya, S.; Nakanishi, H.

    2016-05-01

    In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

  13. Positron Scanner for Locating Brain Tumors

    DOE R&D Accomplishments Database

    Rankowitz, S.; Robertson, J. S.; Higinbotham, W. A.; Rosenblum, M. J.

    1962-03-01

    A system is described that makes use of positron emitting isotopes for locating brain tumors. This system inherently provides more information about the distribution of radioactivity in the head in less time than existing scanners which use one or two detectors. A stationary circular array of 32 scintillation detectors scans a horizontal layer of the head from many directions simultaneously. The data, consisting of the number of counts in all possible coincidence pairs, are coded and stored in the memory of a Two-Dimensional Pulse-Height Analyzer. A unique method of displaying and interpreting the data is described that enables rapid approximate analysis of complex source distribution patterns. (auth)

  14. Positron autoradiography for intravascular imaging: feasibility evaluation

    NASA Astrophysics Data System (ADS)

    Shikhaliev, Polad M.; Xu, Tong; Ducote, Justin L.; Easwaramoorthy, Balasubramaniam; Mukherjee, Jogeshwar; Molloi, Sabee

    2006-02-01

    Approximately 70% of acute coronary artery disease is caused by unstable (vulnerable) plaques with an inflammation of the overlying cap and high lipid content. A rupturing of the inflamed cap of the plaque results in propagation of the thrombus into the lumen, blockage of the artery and acute ischaemic syndrome or sudden death. Morphological imaging such as angiography or intravascular ultrasound cannot determine inflammation status of the plaque. A radiotracer such as 18F-FDG is accumulated in vulnerable plaques due to higher metabolic activity of the inflamed cap and could be used to detect a vulnerable plaque. However, positron emission tomography (PET) cannot detect the FDG-labelled plaques because of respiratory and heart motions, small size and low activity of the plaques. Plaques can be detected using a miniature particle (positron) detector inserted into the artery. In this work, a new detector concept is investigated for intravascular imaging of the plaques. The detector consists of a storage phosphor tip bound to the end of an intravascular catheter. It can be inserted into an artery, absorb the 18F-FDG positrons from the plaques, withdrawn from the artery and read out. Length and diameter of the storage phosphor tip can be matched to the length and the diameter of the artery. Monte Carlo simulations and experimental evaluations of coronary plaque imaging with the proposed detector were performed. It was shown that the sensitivity of the storage phosphor detector to the positrons of 18F-FDG is sufficient to detect coronary plaques with 1 mm and 2 mm sizes and 590 Bq and 1180 Bq activities in the arteries with 2 mm and 3 mm diameters, respectively. An experimental study was performed using plastic tubes with 2 mm diameter filled with an FDG solution, which simulates blood. FDG spots simulating plaques were placed over the surface of the tube. A phosphor tip was inserted into the tube and imaged the plaques. Exposure time was 1 min in all simulations and

  15. Liquid Metal Target for NLC Positron Source

    SciTech Connect

    Sheppard, John C.

    2002-08-19

    Possibility of creating the liquid lead target with parameters, optimum for the NLC positron source, is investigated. Target has a form of titanium vessel, filled with liquid lead, pumped through. The energy deposition in target is characterized by 35 kW average power and up to 250 J/g specific energy at optimum beam sigma 0.6 mm. The use of pumped through liquid lead as target material solves both the problems of power evacuation and target survival. The window for beam exit is made of both temperature and pressure resistive material--the diamond-like ceramic BN.

  16. Positron Emission Tomography: Its 65 years

    NASA Astrophysics Data System (ADS)

    Del Guerra, A.; Belcari, N.; Bisogni, M.

    2016-04-01

    Positron Emission Tomography (PET) is a well-established imaging technique for in vivo molecular imaging. In this review after a brief history of PET there are presented its physical principles and the technology that has been developed for bringing PET from a bench experiment to a clinical indispensable instrument. The limitations and performance of the PET tomographs are discussed, both as for the hardware and software aspects. The status of art of clinical, pre-clinical and hybrid scanners (, PET/CT and PET/MR) is reported. Finally the actual trend and the recent and future technological developments are fully illustrated.

  17. Microstructure Evaluation of Fe-BASED Amorphous Alloys Investigated by Doppler Broadening Positron Annihilation Technique

    NASA Astrophysics Data System (ADS)

    Lu, Wei; Huang, Ping; Wang, Yuxin; Yan, Biao

    2013-07-01

    Microstructure of Fe-based amorphous and nanocrystalline soft magnetic alloy has been investigated by X-ray diffraction (XRD), transmission electronic microscopy (TEM) and Doppler broadening positron annihilation technique (PAT). Doppler broadening measurement reveals that amorphous alloys (Finemet, Type I) which can form a nanocrystalline phase have more defects (free volume) than alloys (Metglas, Type II) which cannot form this microstructure. XRD and TEM characterization indicates that the nanocrystallization of amorphous Finemet alloy occurs at 460°C, where nanocrystallites of α-Fe with an average grain size of a few nanometers are formed in an amorphous matrix. With increasing annealing temperature up to 500°C, the average grain size increases up to around 12 nm. During the annealing of Finemet alloy, it has been demonstrated that positron annihilates in quenched-in defect, crystalline nanophase and amorphous-nanocrystalline interfaces. The change of line shape parameter S with annealing temperature in Finemet alloy is mainly due to the structural relaxation, the pre-nucleation of Cu nucleus and the nanocrystallization of α-Fe(Si) phase during annealing. This study throws new insights into positron behavior in the nanocrystallization of metallic glasses, especially in the presence of single or multiple nanophases embedded in the amorphous matrix.

  18. Applications of positron annihilation spectroscopy in materials research

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.

    1988-01-01

    Positron Annihilation Spectroscopy (PAS) has emerged as a powerful technique for research in condensed matter. It has been used extensively in the study of metals, ionic crystals, glasses and polymers. The present review concentrates on applications of positron lifetime measurements for elucidation of the physicochemical structure of polymers.

  19. Towards laboratory produced relativistic electron–positron pair plasmas

    SciTech Connect

    Chen, Hui; Meyerhofer, D. D.; Wilks, S. C.; Cauble, R.; Dollar, F.; Falk, K.; Gregori, G.; Hazi, A.; Moses, E. I.; Murphy, C. D.; Myatt, J.; Park, J.; Seely, J.; Shepherd, R.; Spitkovsky, A.; Stoeckl, C.; Szabo, C. I.; Tommasini, R.; Zulick, C.; Beiersdorfer, P.

    2011-12-01

    We review recent experimental results on the path to producing electron–positron pair plasmas using lasers. Relativistic pair-plasmas and jets are believed to exist in many astrophysical objects and are often invoked to explain energetic phenomena related to Gamma Ray Bursts and Black Holes. On earth, positrons from radioactive isotopes or accelerators are used extensively at low energies (sub-MeV) in areas related to surface science positron emission tomography and basic antimatter science. Experimental platforms capable of producing the high-temperature pair-plasma and high-flux jets required to simulate astrophysical positron conditions have so far been absent. In the past few years, we performed extensive experiments generating positrons with intense lasers where we found that relativistic electron and positron jets are produced by irradiating a solid gold target with an intense picosecond laser pulse. The positron temperatures in directions parallel and transverse to the beam both exceeded 0.5 MeV, and the density of electrons and positrons in these jets are of order 1016 cm-3 and 1013 cm-3, respectively. With the increasing performance of high-energy ultra-short laser pulses, we expect that a high-density, up to 1018 cm-3, relativistic pair-plasma is achievable, a novel regime of laboratory-produced hot dense matter.

  20. Recent Developments in Positron Emission Tomography (PET) Instrumentation

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors.

  1. Positron-annihilation study of radiation defects in sodium azide

    SciTech Connect

    Etin, G.I.; Ryabykh, S.M.

    1987-07-01

    Annihilation-photon angular correlation has been used to examine radiation defects in sodium azide capable of trapping positrons. The calculated and measured characteristics have been determined for various defects, including micropores filled by radiolytic nitrogen. The positron annihilation rates have been determined for the regions around radiation defects.

  2. Moisture determination in composite materials using positron lifetime techniques

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Holt, W. R.; Mock, W., Jr.

    1980-01-01

    A technique was developed which has the potential of providing information on the moisture content as well as its depth in the specimen. This technique was based on the dependence of positron lifetime on the moisture content of the composite specimen. The positron lifetime technique of moisture determination and the results of the initial studies are described.

  3. Formation of a high intensity low energy positron string

    NASA Astrophysics Data System (ADS)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  4. A Simple Estimate of the Mass of the Positron.

    ERIC Educational Resources Information Center

    Jones, Goronwy Tudor

    1993-01-01

    Discusses a small part of the final state of a high-energy neutrino interaction: a head-on collision of a positron and a stationary electron. Provides a bubble chamber picture and describes the resulting particle effects. Uses momentum to determine the mass of the positron. (MVL)

  5. Monte Carlo modelling of positron transport in real world applications

    NASA Astrophysics Data System (ADS)

    Marjanović, S.; Banković, A.; Šuvakov, M.; Petrović, Z. Lj

    2014-05-01

    Due to the unstable nature of positrons and their short lifetime, it is difficult to obtain high positron particle densities. This is why the Monte Carlo simulation technique, as a swarm method, is very suitable for modelling most of the current positron applications involving gaseous and liquid media. The ongoing work on the measurements of cross-sections for positron interactions with atoms and molecules and swarm calculations for positrons in gasses led to the establishment of good cross-section sets for positron interaction with gasses commonly used in real-world applications. Using the standard Monte Carlo technique and codes that can follow both low- (down to thermal energy) and high- (up to keV) energy particles, we are able to model different systems directly applicable to existing experimental setups and techniques. This paper reviews the results on modelling Surko-type positron buffer gas traps, application of the rotating wall technique and simulation of positron tracks in water vapor as a substitute for human tissue, and pinpoints the challenges in and advantages of applying Monte Carlo simulations to these systems.

  6. Electrons and positrons from expanding supernova envelopes in dense clouds

    NASA Technical Reports Server (NTRS)

    Stephens, S. A.

    1985-01-01

    If antiprotons in cosmic rays are produced as secondary particles in sources, it is expected that positrons are also created by the same process. The interstellar spectra of positrons and electrons are calculated by taking into account such sources. Spectra are then compared with observations.

  7. Recent developments in positron emission tomography (PET) instrumentation

    SciTech Connect

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  8. First positron annihilation lifetime measurement of Pu

    SciTech Connect

    Colmenares, C.; Howell, R.H.; Ancheta, D.; Cowan, T.; Hanafee, J.; Sterne, P.

    1996-11-21

    We have made the first measurement of defects in an aged sample of {delta} phase, Ga stabilized Pu, using positron annihilation lifetime spectroscopy. This measurement validates the procedure necessary to perform measurements on this highly toxic material and obtain data representative of sample conditions. Comparison of the positron annihilation lifetime analysis of the data with calculated values suggests that He filled vacancies or vacancy clusters dominate the defect population. Such defects are the necessary precursor to void growth and swelling. The evolution of defects resulting from the radioactive decay of Pu during its life in the stockpile is one of the unknown quantities affecting our confidence in predictions of the limit on stockpile components. Radiation damage leads to changes in the size and strength of metals studied for reactor and accelerator use and similar effects may be expected in Pu. The evolution of radiation produced vacancies into larger void structures and accompanying macroscopic swelling may occur in Pu at some age. A detailed understanding of the defects in self irradiated Pu is required to predict the time scale of void swelling and related radiation effects. 1 fig.

  9. Analysis of positron lifetime spectra in polymers

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Mall, Gerald H.; Sprinkle, Danny R.

    1988-01-01

    A new procedure for analyzing multicomponent positron lifetime spectra in polymers was developed. It requires initial estimates of the lifetimes and the intensities of various components, which are readily obtainable by a standard spectrum stripping process. These initial estimates, after convolution with the timing system resolution function, are then used as the inputs for a nonlinear least squares analysis to compute the estimates that conform to a global error minimization criterion. The convolution integral uses the full experimental resolution function, in contrast to the previous studies where analytical approximations of it were utilized. These concepts were incorporated into a generalized Computer Program for Analyzing Positron Lifetime Spectra (PAPLS) in polymers. Its validity was tested using several artificially generated data sets. These data sets were also analyzed using the widely used POSITRONFIT program. In almost all cases, the PAPLS program gives closer fit to the input values. The new procedure was applied to the analysis of several lifetime spectra measured in metal ion containing Epon-828 samples. The results are described.

  10. Positron Emission Tomography: A Basic Analysis

    NASA Astrophysics Data System (ADS)

    Kerbacher, M. E.; Deaton, J. W.; Phinney, L. C.; Mitchell, L. J.; Duggan, J. L.

    2007-10-01

    Positron Emission Tomography is useful in detecting biological abnormalities. The technique involves attaching radiotracers to a material used inside the body, in many cases glucose. Glucose is absorbed most readily in areas of unusual cell growth or uptake of nutrients so through natural processes the treated glucose highlights regions of tumors and other degenerative disorders such as Alzheimer's disease. The higher the concentration of isotopes, the more dynamic the area. Isotopes commonly used as tracers are 11C, 18F, 13N, and 15O due to their easy production and short half-lives. Once the tracers have saturated an area of tissue they are detected using coincidence detectors collinear with individual isotopes. As the isotope decays it emits a positron which, upon annihilating an electron, produces two oppositely directioned gamma rays. The PET machine consists of several pairs of detectors, each 180 degrees from their partner detector. When the oppositely positioned detectors are collinear with the area of the isotope, a computer registers the location of the isotope and can compile an image of the activity of the highlighted area based on the position and strength of the isotopes.

  11. Electron-Positron Flows around Magnetars

    NASA Astrophysics Data System (ADS)

    Beloborodov, Andrei M.

    2013-11-01

    The twisted magnetospheres of magnetars must sustain a persistent flow of electron-positron plasma. The flow dynamics is controlled by the radiation field around the hot neutron star. The problem of plasma motion in the self-consistent radiation field is solved using the method of virtual beams. The plasma and radiation exchange momentum via resonant scattering and self-organize into the "radiatively locked" outflow with a well-defined, decreasing Lorentz factor. There is an extended zone around the magnetar where the plasma flow is ultra-relativistic; its Lorentz factor is self-regulated so that it can marginally scatter thermal photons. The flow becomes slow and opaque in an outer equatorial zone, where the decelerated plasma accumulates and annihilates; this region serves as a reflector for the thermal photons emitted by the neutron star. The e ± flow carries electric current, which is sustained by a moderate induced electric field. The electric field maintains a separation between the electron and positron velocities, against the will of the radiation field. The two-stream instability is then inevitable, and the induced turbulence can generate low-frequency emission. In particular, radio emission may escape around the magnetic dipole axis of the star. Most of the flow energy is converted to hard X-ray emission, which is examined in an accompanying paper.

  12. ELECTRON-POSITRON FLOWS AROUND MAGNETARS

    SciTech Connect

    Beloborodov, Andrei M.

    2013-11-10

    The twisted magnetospheres of magnetars must sustain a persistent flow of electron-positron plasma. The flow dynamics is controlled by the radiation field around the hot neutron star. The problem of plasma motion in the self-consistent radiation field is solved using the method of virtual beams. The plasma and radiation exchange momentum via resonant scattering and self-organize into the 'radiatively locked' outflow with a well-defined, decreasing Lorentz factor. There is an extended zone around the magnetar where the plasma flow is ultra-relativistic; its Lorentz factor is self-regulated so that it can marginally scatter thermal photons. The flow becomes slow and opaque in an outer equatorial zone, where the decelerated plasma accumulates and annihilates; this region serves as a reflector for the thermal photons emitted by the neutron star. The e {sup ±} flow carries electric current, which is sustained by a moderate induced electric field. The electric field maintains a separation between the electron and positron velocities, against the will of the radiation field. The two-stream instability is then inevitable, and the induced turbulence can generate low-frequency emission. In particular, radio emission may escape around the magnetic dipole axis of the star. Most of the flow energy is converted to hard X-ray emission, which is examined in an accompanying paper.

  13. Development of a Positron Source for JLab at the IAC

    SciTech Connect

    Forest, Tony

    2013-10-12

    We report on the research performed towards the development of a positron sour for Jefferson Lab's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, VA. The first year of work was used to benchmark the predictions of our current simulation with positron production efficiency measurements at the IAC. The second year used the benchmarked simulation to design a beam line configuration which optimized positron production efficiency while minimizing radioactive waste as well as design and construct a positron converter target. The final year quantified the performance of the positron source. This joint research and development project brought together the experiences of both electron accelerator facilities. Our intention is to use the project as a spring board towards developing a program of accelerator based research and education which will train students to meet the needs of both facilities as well as provide a pool of trained scientists.

  14. Positron beam lifetime spectroscopy at Lawrence Livermore National Laboratory

    SciTech Connect

    Howell, R.H.; Cowan, T.E.; Hartley, J.H.; Stern, P.A. |

    1996-10-01

    Defect analysis is needed for samples ranging in thickness from thin films to large engineering parts. We are meeting that need with two positron beam lifetime spectrometers: on on a 3 MeV electrostatic accelerator and the second on our high current linac beam. The high energy beam spectrometer performs positron lifetime analysis on thick samples which can be encapsulated for containment or for in situ measurements in controlled environments. At our high current beam, we are developing a low energy, microscopically focused, pulsed positron beam to enable positron annihilation lifetime spectroscopy for defect specific, 3-D maps with sub-micron location resolution. The data from these instruments with the aid of first principles calculations of defect specific positron lifetimes.

  15. Intraprocedural yttrium-90 positron emission tomography/CT for treatment optimization of yttrium-90 radioembolization.

    PubMed

    Bourgeois, Austin C; Chang, Ted T; Bradley, Yong C; Acuff, Shelley N; Pasciak, Alexander S

    2014-02-01

    Radioembolization with yttrium-90 ((90)Y) microspheres relies on delivery of appropriate treatment activity to ensure patient safety and optimize treatment efficacy. We report a case in which (90)Y positron emission tomography (PET)/computed tomography (CT) was performed to optimize treatment planning during a same-day, three-part treatment session. This treatment consisted of (i) an initial (90)Y infusion with a dosage determined using an empiric treatment planning model, (ii) quantitative (90)Y PET/CT imaging, and (iii) a secondary infusion with treatment planning based on quantitative imaging data with the goal of delivering a specific total tumor absorbed dose.

  16. The multi-scattering model for calculations of positron spatial distribution in the multilayer stacks, useful for conventional positron measurements

    SciTech Connect

    Dryzek, Jerzy; Siemek, Krzysztof

    2013-08-21

    The spatial distribution of positrons emitted from radioactive isotopes into stacks or layered samples is a subject of the presented report. It was found that Monte Carlo (MC) simulations using GEANT4 code are not able to describe correctly the experimental data of the positron fractions in stacks. The mathematical model was proposed for calculations of the implantation profile or positron fractions in separated layers or foils being components of a stack. The model takes into account only two processes, i.e., the positron absorption and backscattering at interfaces. The mathematical formulas were applied in the computer program called LYS-1 (layers profile analysis). The theoretical predictions of the model were in the good agreement with the results of the MC simulations for the semi infinite sample. The experimental verifications of the model were performed on the symmetrical and non-symmetrical stacks of different foils. The good agreement between the experimental and calculated fractions of positrons in components of a stack was achieved. Also the experimental implantation profile obtained using the depth scanning of positron implantation technique is very well described by the theoretical profile obtained within the proposed model. The LYS-1 program allows us also to calculate the fraction of positrons which annihilate in the source, which can be useful in the positron spectroscopy.

  17. Roles of superthermal electrons and positrons on positron-acoustic solitary waves and double layers in electron-positron-ion plasmas.

    PubMed

    Alam, M S; Uddin, M J; Masud, M M; Mamun, A A

    2014-09-01

    Positron-acoustic (PA) solitary waves (SWs) and double layers (DLs) in four-component plasmas consisting of immobile positive ions, mobile cold positrons, and superthermal (kappa distributed) hot positrons and electrons are investigated both numerically and analytically by deriving Korteweg-de Vries (K-dV), modified K-dV (mK-dV), and Gardner equations along with their DLs solutions using the reductive perturbation method. It is examined that depending on the plasma parameters, the K-dV SWs, Gardner SWs, and DLs support either compressive or rarefactive structures, whereas mK-dV SWs support only compressive structure. It is also found that the presence of superthermal (kappa distributed) hot positrons and hot electrons significantly modify the basic features of PA SWs as well as PA DLs. Besides, the critical number density ratio of hot positrons and cold positrons play an important role in the polarity of PA SWs and DLs. The implications of our results in different space as well as laboratory plasma environments are briefly discussed.

  18. The impact of positrons beam on the propagation of super freak waves in electron-positron-ion plasmas

    NASA Astrophysics Data System (ADS)

    Ali Shan, S.; El-Tantawy, S. A.

    2016-07-01

    In this work, we examine the nonlinear propagation of planar ion-acoustic freak waves in an unmagnetized plasma consisting of cold positive ions and superthermal electrons subjected to cold positrons beam. For this purpose, the reductive perturbation method is used to derive a nonlinear Schrödinger equation (NLSE) for the evolution of electrostatic potential wave. We determine the domain of the plasma parameters where the rogue waves exist. The effect of the positron beam on the modulational instability of the ion-acoustic rogue waves is discussed. It is found that the region of the modulational stability is enhanced with the increase of positron beam speed and positron population. Second as positrons beam increases the nonlinearities of the plasma system, large amplitude ion acoustic rogue waves are pointed out. The present results will be helpful in providing a good fit between the theoretical analysis and real applications in future laboratory plasma experiments.

  19. Applicability of modified effective-range theory to positron-atom and positron-molecule scattering

    SciTech Connect

    Idziaszek, Zbigniew; Karwasz, Grzegorz

    2006-06-15

    We analyze low-energy scattering of positrons on Ar atoms and N{sub 2} molecules using the modified effective-range theory (MERT) developed by O'Malley, et al. [J. Math. Phys. 2, 491 (1961)]. We use the formulation of MERT based on exact solutions of the Schroedinger equation with polarization potential rather than low-energy expansions of phase shifts into momentum series. We show that MERT describes the experimental data well, provided that effective-range expansion is performed both for s- and p-wave scattering, which dominate in the considered regime of positron energies (0.4-2 eV). We estimate the values of the s-wave scattering length and the effective range for e{sup +}-Ar and e{sup +}-N{sub 2} collisions.

  20. Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses

    SciTech Connect

    Taira, Y.; Toyokawa, H.; Kuroda, R.; Yamamoto, N.; Adachi, M.; Tanaka, S.; Katoh, M.

    2013-05-15

    High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90 Degree-Sign collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF{sub 2} scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF{sub 2} scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured.

  1. Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses.

    PubMed

    Taira, Y; Toyokawa, H; Kuroda, R; Yamamoto, N; Adachi, M; Tanaka, S; Katoh, M

    2013-05-01

    High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90° collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF2 scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF2 scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured.

  2. Positron Emission Tomography of the Heart

    DOE R&D Accomplishments Database

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.

  3. Compact conscious animal positron emission tomography scanner

    DOEpatents

    Schyler, David J.; O'Connor, Paul; Woody, Craig; Junnarkar, Sachin Shrirang; Radeka, Veljko; Vaska, Paul; Pratte, Jean-Francois; Volkow, Nora

    2006-10-24

    A method of serially transferring annihilation information in a compact positron emission tomography (PET) scanner includes generating a time signal for an event, generating an address signal representing a detecting channel, generating a detector channel signal including the time and address signals, and generating a composite signal including the channel signal and similarly generated signals. The composite signal includes events from detectors in a block and is serially output. An apparatus that serially transfers annihilation information from a block includes time signal generators for detectors in a block and an address and channel signal generator. The PET scanner includes a ring tomograph that mounts onto a portion of an animal, which includes opposing block pairs. Each of the blocks in a block pair includes a scintillator layer, detection array, front-end array, and a serial encoder. The serial encoder includes time signal generators and an address signal and channel signal generator.

  4. Tumor Quantification in Clinical Positron Emission Tomography

    PubMed Central

    Bai, Bing; Bading, James; Conti, Peter S

    2013-01-01

    Positron emission tomography (PET) is used extensively in clinical oncology for tumor detection, staging and therapy response assessment. Quantitative measurements of tumor uptake, usually in the form of standardized uptake values (SUVs), have enhanced or replaced qualitative interpretation. In this paper we review the current status of tumor quantification methods and their applications to clinical oncology. Factors that impede quantitative assessment and limit its accuracy and reproducibility are summarized, with special emphasis on SUV analysis. We describe current efforts to improve the accuracy of tumor uptake measurements, characterize overall metabolic tumor burden and heterogeneity of tumor uptake, and account for the effects of image noise. We also summarize recent developments in PET instrumentation and image reconstruction and their impact on tumor quantification. Finally, we offer our assessment of the current development needs in PET tumor quantification, including practical techniques for fully quantitative, pharmacokinetic measurements. PMID:24312151

  5. Positron Emission Tomography with improved spatial resolution

    SciTech Connect

    Drukier, A.K.

    1990-04-01

    Applied Research Corporation (ARC) proposed the development of a new class of solid state detectors called Superconducting Granular Detectors (SGD). These new detectors permit considerable improvements in medical imaging, e.g. Positron Emission Tomography (PET). The biggest impact of this technique will be in imaging of the brain. It should permit better clinical diagnosis of such important diseases as Altzheimer's or schizophrenia. More specifically, we will develop an improved PET-imager; a spatial resolution 2 mm may be achievable with SGD. A time-of-flight capability(t {approx} 100 psec) will permit better contrast and facilitate 3D imaging. In the following, we describe the results of the first 9 months of the development.

  6. Instrumentation optimization for positron emission mammography

    SciTech Connect

    Moses, William W.; Qi, Jinyi

    2003-06-05

    The past several years have seen designs for PET cameras optimized to image the breast, commonly known as Positron Emission Mammography or PEM cameras. The guiding principal behind PEM instrumentation is that a camera whose field of view is restricted to a single breast has higher performance and lower cost than a conventional PET camera. The most common geometry is a pair of parallel planes of detector modules, although geometries that encircle the breast have also been proposed. The ability of the detector modules to measure the depth of interaction (DOI) is also a relevant feature. This paper finds that while both the additional solid angle coverage afforded by encircling the breast and the decreased blurring afforded by the DOI measurement improve performance, the ability to measure DOI is more important than the ability to encircle the breast.

  7. The source and distribution of Galactic positrons

    NASA Technical Reports Server (NTRS)

    Purcell, W. R.; Dixon, D. D.; Cheng, L.-X.; Leventhal, M.; Kinzer, R. L.; Kurfess, J. D.; Skibo, J. G.; Smith, D. M.; Tueller, J.

    1997-01-01

    The oriented scintillation spectrometer experiment (OSSE) observations of the Galactic plane and the Galactic center region were combined with observations acquired with other instruments in order to produce a map of the Galactic 511 keV annihilation radiation. Two mapping techniques were applied to the data: the maximum entropy method, and the basis pursuit inversion method. The resulting maps are qualitatively similar and show evidence for a central bulge and a weak galactic disk component. The weak disk is consistent with that expected from positrons produced by the decay of radioactive Al-26 in the interstellar medium. Both maps suggest an enhanced region of emission near l = -4 deg, b = 7 deg, with a flux of approximately 50 percent of that of the bulge. The existence of this emission appears significant, although the location is not well determined. The source of this enhanced emission is presently unknown.

  8. Positrons and Antiprotons in Galactic Cosmic Rays

    NASA Astrophysics Data System (ADS)

    Cowsik, R.

    2016-10-01

    I consider the impact of recent measurements of positron and antiproton spectra in cosmic rays on our understanding of the origins and propagation of cosmic rays, as well as on the annihilation and decay characteristics of particles of Galactic dark matter, from the perspective of current models postulating energy-dependent leakage of cosmic rays from the Galaxy and of the nested leaky-box model, in which the leakage from the Galaxy is independent of energy. The nested leaky-box model provides a straightforward and consistent explanation of the observed spectral intensities, and finds no compelling need for a contribution from the annihilation or decay of Galactic dark matter. Improved observations and modeling efforts are needed to probe the properties of dark matter deeply enough to be significant to particle physics and cosmology.

  9. Making Relativistic Positrons Using Ultra-Intense Short Pulse Lasers

    SciTech Connect

    Chen, H; Wilks, S; Bonlie, J; Chen, C; Chen, S; Cone, K; Elberson, L; Gregori, G; Liang, E; Price, D; Van Maren, R; Meyerhofer, D D; Mithen, J; Murphy, C V; Myatt, J; Schneider, M; Shepherd, R; Stafford, D; Tommasini, R; Beiersdorfer, P

    2009-08-24

    This paper describes a new positron source produced using ultra-intense short pulse lasers. Although it has been studied in theory since as early as the 1970s, the use of lasers as a valuable new positron source was not demonstrated experimentally until recent years, when the petawatt-class short pulse lasers were developed. In 2008 and 2009, in a series of experiments performed at Lawrence Livermore National Laboratory, a large number of positrons were observed after shooting a millimeter thick solid gold target. Up to 2 x 10{sup 10} positrons per steradian ejected out the back of {approx}mm thick gold targets were detected. The targets were illuminated with short ({approx}1 ps) ultra-intense ({approx}1 x 10{sup 20} W/cm{sup 2}) laser pulses. These positrons are produced predominantly by the Bethe-Heitler process, and have an effective temperature of 2-4 MeV, with the distribution peaking at 4-7 MeV. The angular distribution of the positrons is anisotropic. For a wide range of applications, this new laser based positron source with its unique characteristics may complements the existing sources using radioactive isotopes and accelerators.

  10. The Calibration of the PEPPo Polarimeter for Electrons and Positrons

    SciTech Connect

    Adeyemi, Adeleke Hakeem; Voutier, Eric J-.M.

    2013-06-01

    The PEPPo (Polarized Electrons for Polarized Positrons) experiment at Jefferson Laboratory investigated the polarization transfer from longitudinally polarized electrons to longitudinally polarized positrons, with the aim of developing this technology for a low energy (~MeV) polarized positron source. Polarization of the positrons was measured by means of a Compton transmission polarimeter where incoming positrons transfer their polarization into circularly polarized photons that were subsequently analyzed by a thick polarized iron target. The measurement of the transmitted photon flux with respect to the orientation of the target polarization (+-) or the helicity (+-) of the incoming leptons provided the measurement of their polarization. Similar measurements with a known electron beam were also performed for calibration purposes. This presentation will describe the apparatus and calibrations performed at the injector at the Jefferson Laboratory to measure positron polarization in the momentum range 3.2-6.2 MeV/c, specifically to quantify the positron analyzing power from electron experimental data measured over a comparable momentum range.

  11. Positron scattering measurements for application to medical physics

    NASA Astrophysics Data System (ADS)

    Sullivan, James

    2015-09-01

    While the use of positrons in medical imaging is now well established, there is still much to learn regarding the transport of positrons through the body, and the subsequent damage induced. Current models of dosimetry use only a crude approximation of the collision physics involved, and at low energies misrepresent the thermalisation process to a considerable degree. Recently, collaborative work has commenced to attempt to refine these models, incorporating a better representation of the underlying physics and trying to gain a better understanding of the damage done after the emission of a positron from a medical radioisotope. This problem is being attacked from several different angles, with new models being developed based upon established techniques in plasma and swarm physics. For all these models, a realistic representation of the collision processes of positrons with relevant molecular species is required. At the Australian National University, we have undertaken a program of measurements of positron scattering from a range of molecules that are important in biological systems, with a focus on analogs to DNA. This talk will present measurements of positron scattering from a range of these molecules, as well as describing the experimental techniques employed to make such measurements. Targets have been measured that are both liquid and solid at room temperature, and new approaches have been developed to get absolute cross section data. The application of the data to various models of positron thermalisation will also be described.

  12. Making relativistic positrons using ultraintense short pulse lasers

    SciTech Connect

    Chen Hui; Wilks, S. C.; Bonlie, J. D.; Chen, S. N.; Cone, K. V.; Elberson, L. N.; Price, D. F.; Schneider, M. B.; Shepherd, R.; Stafford, D. C.; Tommasini, R.; Van Maren, R.; Beiersdorfer, P.; Gregori, G.; Meyerhofer, D. D.; Myatt, J.

    2009-12-15

    This paper describes a new positron source using ultraintense short pulse lasers. Although it has been theoretically studied since the 1970s, the use of lasers as a valuable new positron source was not demonstrated experimentally until recent years, when the petawatt-class short pulse lasers were developed. In 2008 and 2009, in a series of experiments performed at the Lawrence Livermore National Laboratory, a large number of positrons were observed after shooting a millimeter thick solid gold target. Up to 2x10{sup 10} positrons/s ejected at the back of approximately millimeter thick gold targets were detected. The targets were illuminated with short (approx1 ps) ultraintense (approx1x10{sup 20} W/cm{sup 2}) laser pulses. These positrons are produced predominantly by the Bethe-Heitler process and have an effective temperature of 2-4 MeV, with the distribution peaking at 4-7 MeV. The angular distribution of the positrons is anisotropic. For a wide range of applications, this new laser-based positron source with its unique characteristics may complement the existing sources based on radioactive isotopes and accelerators.

  13. Data for modeling of positron collisions and transport in gases

    NASA Astrophysics Data System (ADS)

    Petrović, Z. Lj.; Banković, A.; Dujko, S.; Marjanović, S.; Malović, G.; Sullivan, J. P.; Buckman, S. J.

    2013-07-01

    We review the current status of positron cross sections for collisions with atoms and molecules from the viewpoint of their use in studies of positron transport processes in gases, liquids and human tissue. The data include cross sections for positron scattering in rare gases, molecular gases (eg., for N2, H2, CO2, CF4) and in particular for organic molecules and those relevant for applications in medicine (e.g. formic acid and water vapor). The cross sections were taken from an assessment of previously published positron-target cross sections. All of the cross sections are based on binary collision measurements and theoretical calculations, and they were not explicitly modified according to the standard swarm analysis. The main reason for this is systematic lack of experimental data for positron transport properties in gases. However, we believe that our compiled sets of cross sections are at level of sophistication, and of sufficient accuracy, to provide correct interpretation of future positron-based experiments. Using these cross sections as an input in our Monte Carlo simulations and Boltzmann equation treatment, we review some interesting points observed in the profiles of various transport coefficients for positrons in gases. Particular emphasis is placed upon the analysis of kinetic phenomena generated by the explicit influence of Ps formation.

  14. A combined matrix isolation spectroscopy and cryosolid positron moderation apparatus

    SciTech Connect

    Molek, Christopher D.; Michael Lindsay, C.; Fajardo, Mario E.

    2013-03-15

    We describe the design, construction, and operation of a novel apparatus for investigating efficiency improvements in thin-film cryogenic solid positron moderators. We report results from solid neon, argon, krypton, and xenon positron moderators which illustrate the capabilities and limitations of our apparatus. We integrate a matrix isolation spectroscopy diagnostic within a reflection-geometry positron moderation system. We report the optical thickness, impurity content, and impurity trapping site structures within our moderators determined from infrared absorption spectra. We use a retarding potential analyzer to modulate the flow of slow positrons, and report positron currents vs. retarding potential for the different moderators. We identify vacuum ultraviolet emissions from irradiated Ne moderators as the source of spurious signals in our channel electron multiplier slow positron detection channel. Our design is also unusual in that it employs a sealed radioactive Na-22 positron source which can be translated relative to, and isolated from, the cryogenic moderator deposition substrate. This allows us to separate the influences on moderator efficiency of surface contamination by residual gases from those of accumulated radiation damage.

  15. Scattering of positrons and electrons by alkali atoms

    NASA Technical Reports Server (NTRS)

    Stein, T. S.; Kauppila, W. E.; Kwan, C. K.; Lukaszew, R. A.; Parikh, S. P.; Wan, Y. J.; Zhou, S.; Dababneh, M. S.

    1990-01-01

    Absolute total scattering cross sections (Q sub T's) were measured for positrons and electrons colliding with sodium, potassium, and rubidium in the 1 to 102 eV range, using the same apparatus and experimental approach (a beam transmission technique) for both projectiles. The present results for positron-sodium and -rubidium collisions represent the first Q sub T measurements reported for these collision systems. Features which distinguish the present comparisons between positron- and electron-alkali atom Q sub T's from those for other atoms and molecules (room-temperature gases) which have been used as targets for positrons and electrons are the proximity of the corresponding positron- and electron-alkali atom Q sub T's over the entire energy range of overlap, with an indication of a merging or near-merging of the corresponding positron and electron Q sub T's near (and above) the relatively low energy of about 40 eV, and a general tendency for the positron-alkali atom Q sub T's to be higher than the corresponding electron values as the projectile energy is decreased below about 40 eV.

  16. Existing Pittsburgh Compound-B positron emission tomography thresholds are too high: statistical and pathological evaluation.

    PubMed

    Villeneuve, Sylvia; Rabinovici, Gil D; Cohn-Sheehy, Brendan I; Madison, Cindee; Ayakta, Nagehan; Ghosh, Pia M; La Joie, Renaud; Arthur-Bentil, Samia Kate; Vogel, Jacob W; Marks, Shawn M; Lehmann, Manja; Rosen, Howard J; Reed, Bruce; Olichney, John; Boxer, Adam L; Miller, Bruce L; Borys, Ewa; Jin, Lee-Way; Huang, Eric J; Grinberg, Lea T; DeCarli, Charles; Seeley, William W; Jagust, William

    2015-07-01

    Amyloid-β, a hallmark of Alzheimer's disease, begins accumulating up to two decades before the onset of dementia, and can be detected in vivo applying amyloid-β positron emission tomography tracers such as carbon-11-labelled Pittsburgh compound-B. A variety of thresholds have been applied in the literature to define Pittsburgh compound-B positron emission tomography positivity, but the ability of these thresholds to detect early amyloid-β deposition is unknown, and validation studies comparing Pittsburgh compound-B thresholds to post-mortem amyloid burden are lacking. In this study we first derived thresholds for amyloid positron emission tomography positivity using Pittsburgh compound-B positron emission tomography in 154 cognitively normal older adults with four complementary approaches: (i) reference values from a young control group aged between 20 and 30 years; (ii) a Gaussian mixture model that assigned each subject a probability of being amyloid-β-positive or amyloid-β-negative based on Pittsburgh compound-B index uptake; (iii) a k-means cluster approach that clustered subjects into amyloid-β-positive or amyloid-β-negative based on Pittsburgh compound-B uptake in different brain regions (features); and (iv) an iterative voxel-based analysis that further explored the spatial pattern of early amyloid-β positron emission tomography signal. Next, we tested the sensitivity and specificity of the derived thresholds in 50 individuals who underwent Pittsburgh compound-B positron emission tomography during life and brain autopsy (mean time positron emission tomography to autopsy 3.1 ± 1.8 years). Amyloid at autopsy was classified using Consortium to Establish a Registry for Alzheimer's Disease (CERAD) criteria, unadjusted for age. The analytic approaches yielded low thresholds (standard uptake value ratiolow = 1.21, distribution volume ratiolow = 1.08) that represent the earliest detectable Pittsburgh compound-B signal, as well as high thresholds (standard

  17. Applications and advances of positron beam spectroscopy: appendix a

    SciTech Connect

    Howell, R. H., LLNL

    1997-11-05

    Over 50 scientists from DOE-DP, DOE-ER, the national laboratories, academia and industry attended a workshop held on November 5-7, 1997 at Lawrence Livermore National Laboratory jointly sponsored by the DOE-Division of Materials Science, The Materials Research Institute at LLNL and the University of California Presidents Office. Workshop participants were charged to address two questions: Is there a need for a national center for materials analysis using positron techniques and can the capabilities at Lawrence Livermore National Laboratory serve this need. To demonstrate the need for a national center the workshop participants discussed the technical advantages enabled by high positron currents and advanced measurement techniques, the role that these techniques will play in materials analysis and the demand for the data. There were general discussions lead by review talks on positron analysis techniques, and their applications to problems in semiconductors, polymers and composites, metals and engineering materials, surface analysis and advanced techniques. These were followed by focus sessions on positron analysis opportunities in these same areas. Livermore now leads the world in materials analysis capabilities by positrons due to developments in response to demands of science based stockpile stewardship. There was a detailed discussion of the LLNL capabilities and a tour of the facilities. The Livermore facilities now include the worlds highest current beam of keV positrons, a scanning pulsed positron microprobe under development capable of three dimensional maps of defect size and concentration, an MeV positron beam for defect analysis of large samples, and electron momentum spectroscopy by positrons. This document is a supplement to the written summary report. It contains a complete schedule, list of attendees and the vuegraphs for the presentations in the review and focus sessions.

  18. Positron production using a 1.7 MV pelletron accelerator

    SciTech Connect

    Alcantara, K. F.; Santos, A. C. F.; Crivelli, P.

    2013-04-19

    We report the foremost phase of a fourth generation positron source, being constructed at the Federal University of Rio de Janeiro. Positron yields are reported by making use of the {sup 19}F(p,{alpha}e{sup +}e{sup -}){sup 16}O reaction, where the fluorine target is in the form of a CaF{sub 2} pellet. Positron production has been observed by detecting 511 keV annihilation gamma rays emerging from the irradiated CaF{sub 2} target.

  19. Bulk defect analysis with a high-energy positron beam

    SciTech Connect

    Hartley, J. H.; Howell, R. H.; Sterne, P. A.

    1998-09-23

    A program using a positron beam to probe defects in bulk materials has been developed at Lawrence Livermore National Laboratory. Positron annihilation lifetime spectroscopy (PALS) provides non-destructive analysis of average defect size and concentration. A 3 MeV positron beam is supplied by Sodium-22 at the terminal of a Pelletron accelerator. The high-energy beam allows large (greater than or equal to 1 cm2) engineering samples to be measured in air or even sealed in an independent environment. A description of the beam-PALS system will be presented along with a summary of recent measuremen

  20. High intensity positron beam and angular correlation experiments at Livermore

    SciTech Connect

    Howell, R.H.; Rosenberg, I.J.; Meyer, P.; Fluss, M.J.

    1985-03-01

    A positron beam apparatus that produces a variable energy positron beam with sufficient intensity to perform new positron experiments in an ultrahigh vacuum environment has been installed at the Lawrence Livermore 100 MeV electron linac. We have installed two large area position sensitive gamma-ray detectors to measure angular correlations in two dimensions and a separate highly collimated detector to measure positronium energy distributions by time-of-flight velocity determination. Data from measurements on single crystals of Cu will be described.

  1. Progress toward positron-electron pair plasma experiments

    SciTech Connect

    Stenson, E. V.; Stanja, J.; Hergenhahn, U.; Saitoh, H.; Niemann, H.; Pedersen, T. Sunn; Marx, G. H.; Schweikhard, L.; Danielson, J. R.; Surko, C. M.; Hugenschmidt, C.

    2015-06-29

    Electron-positron plasmas have been of theoretical interest for decades, due to the unique plasma physics that arises from all charged particles having precisely identical mass. It is only recently, though, that developments in non-neutral plasma physics (both in linear and toroidal geometries) and in the flux of sources for cold positrons have brought the goal of conducting electron-positron pair plasma experiments within reach. The APEX/PAX collaboration is working on a number of projects in parallel toward that goal; this paper provides an overview of recent, current, and upcoming activities.

  2. Anti-hydrogen production with positron beam ion trap

    SciTech Connect

    Itahashi, Takahisa

    2008-08-08

    In low-energy antiproton physics, it is advantageous to be able to manipulate anti-particles as freely as normal particles. A robust production and storage system for high-quality positrons and antiprotons would be a substantial advance for the development of anti-matter science. The idea of electron beam ion trap could be applied for storage of anti-particle when the electron beam could be replaced by the positron beam. The bright positron beam would be brought about using synchrotron radiation source with a superconducting wiggler. The new scheme for production of anti-particles is proposed by using new accelerator technologies.

  3. Positrons in the Galaxy: Their Births, Marriages and Deaths

    NASA Technical Reports Server (NTRS)

    Skinner, Gerald K.

    2010-01-01

    High energy (approximately GeV) positrons are seen within cosmic rays and observation of a narrow line at 511 keV shows that positrons are annihilating in the galaxy after slowing down to approximately keV energies or less. Our state of knowledge of the origin of these positrons, of the formation of positronium 'atoms', and of the circumstances of their annihilation or escape from the galaxy are reviewed and the question of whether the two phenomena are linked is discussed.

  4. Positronic molecule calculations using Monte Carlo configuration interaction

    NASA Astrophysics Data System (ADS)

    Coe, Jeremy P.; Paterson, Martin J.

    2016-02-01

    We modify the Monte Carlo configuration interaction procedure to model atoms and molecules combined with a positron. We test this method with standard quantum chemistry basis sets on a number of positronic systems and compare results with the literature and full configuration interaction when appropriate. We consider positronium hydride, positronium hydroxide, lithium positride and a positron interacting with lithium, magnesium or lithium hydride. We demonstrate that we can capture much of the full configuration interaction results, but often require less than 10% of the configurations of these multireference wavefunctions. The effect of the number of frozen orbitals is also discussed.

  5. Methods and applications of positron-based medical imaging

    NASA Astrophysics Data System (ADS)

    Herzog, H.

    2007-02-01

    Positron emission tomography (PET) is a diagnostic imaging method to examine metabolic functions and their disorders. Dedicated ring systems of scintillation detectors measure the 511 keV γ-radiation produced in the course of the positron emission from radiolabelled metabolically active molecules. A great number of radiopharmaceuticals labelled with 11C, 13N, 15O, or 18F positron emitters have been applied both for research and clinical purposes in neurology, cardiology and oncology. The recent success of PET with rapidly increasing installations is mainly based on the use of [ 18F]fluorodeoxyglucose (FDG) in oncology where it is most useful to localize primary tumours and their metastases.

  6. Theoretical survey on positronium formation and ionisation in positron atom scattering

    NASA Technical Reports Server (NTRS)

    Basu, Madhumita; Ghosh, A. S.

    1990-01-01

    The recent theoretical studies are surveyed and reported on the formation of exotic atoms in positron-hydrogen, positron-helium and positron-lithium scattering specially at intermediate energy region. The ionizations of these targets by positron impact was also considered. Theoretical predictions for both the processes are compared with existing measured values.

  7. Positron acceleration in plasma bubble wakefield driven by an ultraintense laser

    SciTech Connect

    Hou, Ya-Juan; Wan, Feng; Sang, Hai-Bo Xie, Bai-Song

    2016-01-15

    The dynamics of positrons accelerating in electron-positron-ion plasma bubble fields driven by an ultraintense laser is investigated. The bubble wakefield is obtained theoretically when laser pulses are propagating in the electron-positron-ion plasma. To restrict the positrons transversely, an electron beam is injected. Acceleration regions and non-acceleration ones of positrons are obtained by the numerical simulation. It is found that the ponderomotive force causes the fluctuation of the positrons momenta, which results in the trapping of them at a lower ion density. The energy gaining of the accelerated positrons is demonstrated, which is helpful for practical applications.

  8. Enhanced positron trapping by Ag nanoclusters at low temperatures: A challenge of positron sensitivity to quantum dots

    NASA Astrophysics Data System (ADS)

    Zou, B.; Qi, N.; Liu, Z. W.; Chen, Z. Q.; Liu, H. Q.; Yi, D. Q.; Tang, Z.

    2017-03-01

    Microstructure evolution of three Al-Ag alloys with different Ag contents (1 wt. % Ag, 5 wt. % Ag, and 15 wt. % Ag) was studied by positron annihilation spectroscopy during the aging process. In situ measurements of the positron lifetime and Doppler broadening of annihilation radiation indicate the fast formation of Ag-rich clusters during natural aging of the alloys. The formation of Ag-rich clusters was further confirmed by coincidence Doppler broadening measurements. The Ag signal reflected by the Coincidence Doppler broadening spectrum increases with increasing Ag content and is further enhanced after subsequent artificial aging at 140 °C. This might be due to the increase in the size of Ag clusters. The temperature dependence of the Doppler broadening spectra between 10 K and 290 K was measured for the Al-Ag alloys after natural and artificial aging. Detrapping of positrons from Ag clusters with increasing temperature was observed for all the three Al-Ag alloys after natural aging and for the Al-1 wt. % Ag after artificial aging. This indicates that Ag clusters act as shallow positron trapping centers. The thermal detrapping of positrons becomes ambiguous with increasing Ag content in the alloy and is nearly invisible in the artificially aged Al-5 wt. % Ag and Al-15 wt. % Ag. The positron binding energy of the Ag cluster is roughly estimated to be about 18.8 meV and 50 meV in the Al-1 wt. % Ag sample after natural aging and artificial aging at 140 °C, respectively, which suggests that the confinement of positrons in the quantum-dot like state depends on the size or chemical composition of clusters. Theoretical calculations confirm positron trapping by Ag nanoclusters, and the confinement of positrons is enhanced with increasing Ag cluster size.

  9. Positron emission tomography (PET): expanding the horizons of oncology drug development.

    PubMed

    Hammond, Lisa A; Denis, Louis; Salman, Umber; Jerabek, Paul; Thomas, Charles R; Kuhn, John G

    2003-08-01

    Positron emission tomography (PET) allows three-dimensional quantitative determination of the distribution of radioactivity permitting measurement of physiological, biochemical, and pharmacological functions at the molecular level. Until recently, no method existed to directly and noninvasively assess transport and metabolism of neoplastic agents as a function of time in various organs as well as in the tumor. Standard preclinical evaluation of potential anticancer agents entails radiolabeling the agent, usually with tritium or 14C, sacrifice experiments, and high-performance liquid chromatography (HPLC) analysis to determine the biodistribution and metabolism in animals. Radiolabeling agents with positron-emitting radionuclides allows the same information to be obtained as well as in vivo pharmacokinetic (PK) data by animal tissue and plasma sampling in combination with PET scanning. In phase I/II human studies, classic PK measurements can be coupled with imaging measurements to define an optimal dosing schedule and help formulate the design of phase III studies that are essential for drug licensure [1]. Many of the novel agents currently in development are cytostatic rather than cytotoxic and therefore, the traditional standard endpoints in phase I and II studies may no longer be relevant. The use of a specialized imaging modality that allows PK and pharmacodynamic (PD) evaluation of a drug of interest has been proposed to permit rapid and sensitive assessment of the biological effects of novel anticancer agents. The progress to date and the challenges of incorporating PET technology into oncology drug development from the preclinical to clinical setting are reviewed in this article.

  10. Positron lifetime calculation for the elements of the periodic table.

    PubMed

    Campillo Robles, J M; Ogando, E; Plazaola, F

    2007-04-30

    Theoretical positron lifetime values have been calculated systematically for most of the elements of the periodic table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the solid, as well as different parametrizations for the positron enhancement factor and correlation energy. The results obtained have been studied and compared with experimental data, confirming the theoretical trends. As is known, positron lifetimes in bulk show a periodic behaviour with atomic number. These calculations also confirm that monovacancy lifetimes follow the same behaviour. The effects of enhancement factors used in calculations have been commented upon. Finally, we have analysed the effects that f and d electrons have on positron lifetimes.

  11. Positron annihilation characteristics in mesostructural silica films with various porosities

    SciTech Connect

    Xiong, Bangyun; Mao, Wenfeng; Tang, Xiuqin; He, Chunqing

    2014-03-07

    Porous silica films with various porosities were prepared via a sol-gel method using a nonionic amphiphilic triblock copolymer F127 as the structure-directing agent. Doppler broadening of positron annihilation radiation (DBAR) spectra were collected for the prepared films using a variable energy slow positron beam. Different linear relationships between positron annihilation line shape parameters S and W are found for the as-deposited films and calcined ones, indicative of the decomposition of the copolymer porogen in the as-deposited films upon calcination. This also reveals the variation of positron annihilation sites as a function of F127 loading or porosity. Strong correlations between positronium 3γ annihilation fraction, S parameter and porosity of the mesoporous silica films with isolated pores are obtained, which may provide a complementary method to determine closed porosities of mesoporous silica films by DBAR.

  12. Improved generalized gradient approximation for positron states in solids

    NASA Astrophysics Data System (ADS)

    Kuriplach, Jan; Barbiellini, Bernardo

    2014-04-01

    Several first-principles calculations of positron-annihilation characteristics in solids have added gradient corrections to the local-density approximation within the theory by Arponen and Pajanne [Ann. Phys. (NY) 121, 343 (1979), 10.1016/0003-4916(79)90101-5] since this theory systematically overestimates the annihilation rates. As a further remedy, we propose to use gradient corrections for other local-density approximation schemes based on perturbed hypernetted chain and on quantum Monte Carlo results. Our calculations for various metals and semiconductors show that the proposed schemes generally improve the positron lifetimes when they are confronted with experiment. We also compare the resulting positron affinities in solids with data from slow-positron measurements.

  13. Resolvability of defect ensembles with positron annihilation studies

    SciTech Connect

    Fluss, M.J.; Howell, R.H.; Rosenberg, I.J.; Meyer, P.

    1984-11-12

    Recent advances in the use of positron annihilation to study defect ensembles in and on the surfaces of metals, are pointing the way towards studies where particular positron-electron annihilation modes may be identified and studied in the presence of one another. Although a great deal is understood about the annihilation of positrons in ostensibly defect-free metals, much less is understood when the positron annihilates in complex defect systems such as liquid metals, amorphous solids, or at or near the vacuum-solid interface. In this paper the results of three experiments, all of which demonstrate means by which we can resolve various poistron annihilation channels from one another, are discussed.

  14. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    DOE R&D Accomplishments Database

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  15. Probing of Unembedded Metallic Quantum Dots with Positrons

    SciTech Connect

    Fischer, C G; Denison, A B; Weber, M H; Wilcoxon, J P; Woessner, S; Lynn, K G

    2003-08-01

    We employed the two detector coincident Doppler Broadening Technique (coPAS) to investigate Ag, Au and Ag/Au alloy quantum dots of varying sizes which were deposited in thin layers on glass slides. The Ag quantum dots range from 2 to 3 nm in diameter, while the Ag/Au alloy quantum dots exhibit Ag cores of 2 nm and 3 nm and Au shells of varying thickness. We investigate the possibility of positron confinement in the Ag core due to positron affinity differences between Ag and Au. We describe the results and their significance to resolving the issue of whether positrons annihilate within the quantum dot itself or whether surface and positron escape effects play an important role.

  16. Cosmic-ray positron energy spectrum measured by PAMELA.

    PubMed

    Adriani, O; Barbarino, G C; Bazilevskaya, G A; Bellotti, R; Bianco, A; Boezio, M; Bogomolov, E A; Bongi, M; Bonvicini, V; Bottai, S; Bruno, A; Cafagna, F; Campana, D; Carbone, R; Carlson, P; Casolino, M; Castellini, G; De Donato, C; De Santis, C; De Simone, N; Di Felice, V; Formato, V; Galper, A M; Karelin, A V; Koldashov, S V; Koldobskiy, S A; Krutkov, S Y; Kvashnin, A N; Leonov, A; Malakhov, V; Marcelli, L; Martucci, M; Mayorov, A G; Menn, W; Mergé, M; Mikhailov, V V; Mocchiutti, E; Monaco, A; Mori, N; Munini, R; Osteria, G; Palma, F; Papini, P; Pearce, M; Picozza, P; Pizzolotto, C; Ricci, M; Ricciarini, S B; Rossetto, L; Sarkar, R; Scotti, V; Simon, M; Sparvoli, R; Spillantini, P; Stochaj, S J; Stockton, J C; Stozhkov, Y I; Vacchi, A; Vannuccini, E; Vasilyev, G I; Voronov, S A; Yurkin, Y T; Zampa, G; Zampa, N; Zverev, V G

    2013-08-23

    Precision measurements of the positron component in the cosmic radiation provide important information about the propagation of cosmic rays and the nature of particle sources in our Galaxy. The satellite-borne experiment PAMELA has been used to make a new measurement of the cosmic-ray positron flux and fraction that extends previously published measurements up to 300 GeV in kinetic energy. The combined measurements of the cosmic-ray positron energy spectrum and fraction provide a unique tool to constrain interpretation models. During the recent solar minimum activity period from July 2006 to December 2009, approximately 24,500 positrons were observed. The results cannot be easily reconciled with purely secondary production, and additional sources of either astrophysical or exotic origin may be required.

  17. Positron annihilation characteristics in mesostructural silica films with various porosities

    NASA Astrophysics Data System (ADS)

    Xiong, Bangyun; Mao, Wenfeng; Tang, Xiuqin; He, Chunqing

    2014-03-01

    Porous silica films with various porosities were prepared via a sol-gel method using a nonionic amphiphilic triblock copolymer F127 as the structure-directing agent. Doppler broadening of positron annihilation radiation (DBAR) spectra were collected for the prepared films using a variable energy slow positron beam. Different linear relationships between positron annihilation line shape parameters S and W are found for the as-deposited films and calcined ones, indicative of the decomposition of the copolymer porogen in the as-deposited films upon calcination. This also reveals the variation of positron annihilation sites as a function of F127 loading or porosity. Strong correlations between positronium 3γ annihilation fraction, S parameter and porosity of the mesoporous silica films with isolated pores are obtained, which may provide a complementary method to determine closed porosities of mesoporous silica films by DBAR.

  18. Positron computed tomography: current state, clinical results and future trends

    SciTech Connect

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  19. Multiple-ionization of xenon atoms by positron impact

    NASA Technical Reports Server (NTRS)

    Kruse, Georg; Quermann, Andreas; Raith, Wilhelm; Sinapius, Guenther

    1990-01-01

    Previously the cross sections were measured for positronium formation and single ionization by positron impact for He and H2. With the same apparatus, slightly modified, the single and multiple ionization of xenon is now investigated. The principle of the method is the detection of ion and positron in time correlation which allows the discrimination of positronium formation (whereby the positron vanishes) and the destinction of single, double and triple impact ionization (which lead to different ion flight times from the gas target to the ion detector). By using secondary electrons from the positron moderator, similar measurements were performed on electron impact ionization. By comparing with literature values for electron multiple ionization cross sections, the detection-probability ratios were determined for the differently charged ions.

  20. The Role of Chemistry in Positron Emission Tomography.

    ERIC Educational Resources Information Center

    Feliu, Anthony L.

    1988-01-01

    Investigates use of positron emission tomography (PET) to study in-vivo metabolic processes. Discusses methodology of PET and medical uses. Outlines the production of different radioisotopes used in PET radiotracers. Includes selected bibliography. (ML)

  1. An Undulator Based Polarized Positron Source for CLIC

    SciTech Connect

    Liu, Wanming; Gai, Wei; Rinolfi, Louis; Sheppard, John; /SLAC

    2012-07-02

    A viable positron source scheme is proposed that uses circularly polarized gamma rays generated from the main 250 GeV electron beam. The beam passes through a helical superconducting undulator with a magnetic field of {approx} 1 Tesla and a period of 1.15 cm. The gamma-rays produced in the undulator in the energy range between {approx} 3 MeV - 100 MeV will be directed to a titanium target and produce polarized positrons. The positrons are then captured, accelerated and transported to a Pre-Damping Ring (PDR). Detailed parameter studies of this scheme including positron yield, and undulator parameter dependence are presented. Effects on the 250 GeV CLIC main beam, including emittance growth and energy loss from the beam passing through the undulator are also discussed.

  2. Magnetoacoustic solitons in dense astrophysical electron-positron-ion plasmas

    NASA Astrophysics Data System (ADS)

    Hussain, S.; Mahmood, S.; Mushtaq, A.

    2013-08-01

    Nonlinear magnetoacoustic waves in dense electron-positron-ion plasmas are investigated by using three fluid quantum magnetohydrodynamic model. The quantum mechanical effects of electrons and positrons are taken into account due to their Fermionic nature (to obey Fermi statistics) and quantum diffraction effects (Bohm diffusion term) in the model. The reductive perturbation method is employed to derive the Korteweg-de Vries (KdV) equation for low amplitude magnetoacoustic soliton in dense electron-positron-ion plasmas. It is found that positron concentration has significant impact on the phase velocity of magnetoacoustic wave and on the formation of single pulse nonlinear structure. The numerical results are also illustrated by taking into account the plasma parameters of the outside layers of white dwarfs and neutron stars/pulsars.

  3. Positron beam facility at Kyoto University Research Reactor

    NASA Astrophysics Data System (ADS)

    Xu, Q.; Sato, K.; Yoshiie, T.; Sano, T.; Kawabe, H.; Nagai, Y.; Nagumo, K.; Inoue, K.; Toyama, T.; Oshima, N.; Kinomura, A.; Shirai, Y.

    2014-04-01

    A positron beam facility is presently under construction at the Kyoto University Research Reactor (KUR), which is a light-water moderated tank-type reactor operated at a rated thermal power of 5 MW. A cadmium (Cd) - tungsten (W) source similar to that used in NEPOMUC was chosen in the KUR because Cd is very efficient at producing γ-rays when exposed to thermal neutron flux, and W is a widely used in converter and moderator materials. High-energy positrons are moderated by a W moderator with a mesh structure. Electrical lenses and a solenoid magnetic field are used to extract the moderated positrons and guide them to a platform outside of the reactor, respectively. Since Japan is an earthquake-prone country, a special attention is paid for the design of the in-pile positron source so as not to damage the reactor in the severe earthquake.

  4. Positron Emission Tomography-Guided, Focal-Dose Escalation Using Intensity-Modulated Radiotherapy for Head and Neck Cancer

    SciTech Connect

    Madani, Indira . E-mail: indira@krtkg1.ugent.be; Duthoy, Wim; Derie, Cristina R.N.; De Gersem, Werner Ir.; Boterberg, Tom; Saerens, Micky; Jacobs, Filip Ir.; Gregoire, Vincent; Lonneux, Max; Vakaet, Luc; Vanderstraeten, Barbara; Bauters, Wouter; Bonte, Katrien; Thierens, Hubert; Neve, Wilfried de

    2007-05-01

    Purpose: To assess the feasibility of intensity-modulated radiotherapy (IMRT) using positron emission tomography (PET)-guided dose escalation, and to determine the maximum tolerated dose in head and neck cancer. Methods and Materials: A Phase I clinical trial was designed to escalate the dose limited to the [{sup 18}-F]fluoro-2-deoxy-D-glucose positron emission tomography ({sup 18}F-FDG-PET)-delineated subvolume within the gross tumor volume. Positron emission tomography scanning was performed in the treatment position. Intensity-modulated radiotherapy with an upfront simultaneously integrated boost was employed. Two dose levels were planned: 25 Gy (level I) and 30 Gy (level II), delivered in 10 fractions. Standard IMRT was applied for the remaining 22 fractions of 2.16 Gy. Results: Between 2003 and 2005, 41 patients were enrolled, with 23 at dose level I, and 18 at dose level II; 39 patients completed the planned therapy. The median follow-up for surviving patients was 14 months. Two cases of dose-limiting toxicity occurred at dose level I (Grade 4 dermitis and Grade 4 dysphagia). One treatment-related death at dose level II halted the study. Complete response was observed in 18 of 21 (86%) and 13 of 16 (81%) evaluated patients at dose levels I and II (p < 0.7), respectively, with actuarial 1-year local control at 85% and 87% (p n.s.), and 1-year overall survival at 82% and 54% (p = 0.06), at dose levels I and II, respectively. In 4 of 9 patients, the site of relapse was in the boosted {sup 18}F-FDG-PET-delineated region. Conclusions: For head and neck cancer, PET-guided dose escalation appears to be well-tolerated. The maximum tolerated dose was not reached at the investigated dose levels.

  5. A method to detect positron anisotropies with Pamela data

    NASA Astrophysics Data System (ADS)

    Panico, B.; Adriani, O.; Barbarino, G. C.; Bazilevskaya, G. A.; Bellotti, R.; Boezio, M.; Bogomolov, E. A.; Bongi, M.; Bonvicini, V.; Bottai, S.; Bruno, A.; Cafagna, F.; Campana, D.; Carbone, R.; Carlson, P.; Casolino, M.; Castellini, G.; De Donato, C.; De Santis, C.; De Simone, N.; Di Felice, V.; Formato, V.; Galper, A. M.; Giaccari, U.; Karelin, A. V.; Koldashov, S. V.; Koldobskiy, S.; Krutkov, S. Y.; Kvashnin, A. N.; Leonov, A.; Malakhov, V.; Marcelli, L.; Martucci, M.; Mayorov, A. G.; Menn, W.; Merge, M.; Mikhailov, V. V.; Mocchiutti, E.; Monaco, A.; Mori, N.; Munini, R.; Osteria, G.; Palma, F.; Papini, P.; Pearce, M.; Picozza, P.; Pizzolotto, C.; Ricci, M.; Ricciarini, S. B.; Sarkar, R.; Scotti, V.; Simon, M.; Sparvoli, R.; Spillantini, P.; Stozhkov, Y. I.; Vacchi, A.; Vannuccini, E.; Vasilyev, G. I.; Voronov, S. A.; Yurkin, Y. T.; Zampa, G.; Zampa, N.; Zverev, V. G.

    2014-11-01

    The PAMELA experiment is collecting data since 2006; its results indicate the presence of a large flux of positron with respect to electrons in the CR spectrum above 10 GeV. This excess might also be originated in objects such as pulsars and microquasars or through dark matter annihilation. Here the electrons and positrons events collected by PAMELA have been analized searching for anisotropies. The analysis is performed at different angular scales and results will be presented at the conference.

  6. Antihydrogen formation in laser-assisted positron-antiproton scattering

    NASA Astrophysics Data System (ADS)

    Li, Shu-Min; Miao, Yan-Gang; Zhou, Zi-Fang; Chen, Ji; Liu, Yao-Yang

    1998-09-01

    Antihydrogen formation in the laser-assisted positron-antiproton (nonrelativistic) radiative recombination is investigated. The state of incident positron is given by the Coulomb-Volkov wave function. The perturbative dressed wave function of the atom is obtained in the soft-photon approximation. Our calculation shows that for a geometry of laser polarization parallel to the incident direction, the formation cross section of antihydrogen is greatly reduced. Especially at high impact energy, the reduction is remarkable.

  7. A Multicell Trap for Positron Accumulation and Storage

    DTIC Science & Technology

    2006-04-21

    device to accumulate N >_ 1012 positrons (i.e., an increase of a factor of 1000 over current performance) and to store this collection of antimatter ...would be an important step toward the development of even more flexible, portable reservoirs of antimatter with few logistic requirements. The first...N > 1012 positrons (i.e., an increase of a factor of 1000 over current performance) and to store this collection of antimatter as a plasma for times

  8. Positronium formation from positron impact on hydrogen and helium targets

    NASA Astrophysics Data System (ADS)

    Naginey, T. C.; Stacy, Eric W.; Pollock, B. B.; Walters, H. R. J.; Whelan, Colm T.

    2014-06-01

    Charge-exchange cross sections are presented for collisions of positrons with hydrogen and neutral and singly ionized helium targets using a variant of the classical trajectory Monte Carlo approach. As a check on the method a comparison is made with the corresponding proton results. An extended error analysis is presented. Reasonable agreement with available experimental data is found, and the charge-exchange cross section for positrons on He+ is predicted.

  9. Electron positron pair production at RHIC and LHC

    SciTech Connect

    Cem Gueclue, M.

    2008-11-11

    The STAR Collaboration at the Relativistic Heavy Ion Collider present data on electron-positron pair production accompanied by nuclear breakup at small impact parameters where the simultaneous excitation of the two ions, mainly the giant dipole resonance GDR, can occur. We calculate the electron-positron pair production cross section relevant for the STAR experimental setup, and compare our results with the other calculations. We have also predictions for the LHC energies.

  10. Positron emission tomographic imaging of tumors using monoclonal antibodies

    SciTech Connect

    Zalutsky, M.R.

    1992-08-01

    This research project is developing methods for utilizing positron emission tomography (PET) to increase the clinical potential of radiolabeled monoclonal antibodies (MAbs). This report describes the development of methods for labeling MAbs and their fragments with positron-emitting halogen nuclides, fluorine-18 and iodine-124. These nulides were selected because of the widespread availability of F-18 and because of our extensive experience in the development of new protein radiohalogenation methods.

  11. Positron transport and thermalization - the plasma-gas interface

    NASA Astrophysics Data System (ADS)

    Marler, Joan

    2008-11-01

    Low energy positrons are now used in many fields including atomic physics, material science and medicine [1]. Plasma physics is providing new tools for this research, including Penning-Malmberg buffer-gas traps to accumulate positrons and the use of rotating electric fields (the ``rotating wall'' technique) to compress positrons radially and create tailored beams [1]. These devices (now available commercially), which rely in key instances on positron-neutral interactions, are a convenient way to create plasmas and beams for a variety of applications. A deeper understanding of the relevant cooling and loss mechanisms is required to take full advantage of this technology. This talk focuses on a recent study of positrons in such a tenuous gaseous environment in the presence of an applied electric field [2]. Energy-resolved collision cross sections and a Monte Carlo code modified to include positrionium (Ps) formation are used to obtain transport coefficients and the thermalization and Ps-formation rates. A markedly different type of negative differential conductivity is observed (i.e., not seen in electron systems), due to the non-conservative nature of the Ps-formation process. It is particularly prominent in gases with large, highly energy dependent Ps-formation cross sections. The relevance of these calculations to other positron applications will also be discussed, including a currently planned study of positrons in gaseous water. It is hoped that these calculations will inspire a new generation of positron transport experiments.*Work done in collaboration with Z.Lj. Petrovi'c, A. Bankovi'c, M. Suvakov, G. Malovi'c, S. Dujko, S.J. Buckman. 1. C. M. Surko and R. G. Greaves, Phys. Plasmas 11, 2333-2348 (2004).2. A. Bankovi'c, J. P. Marler, M. Suvakov, G. Malovi'c, and Z. Lj. Petrovi'c, Nucl. Instrum. and Meth. in Phys. Res. B 266, 462-465 (2008).

  12. Short-lived positron emitter labeled radiotracers - present status

    SciTech Connect

    Fowler, J.S.; Wolf, A.P.

    1982-01-01

    The preparation of labelled compounds is important for the application of positron emission transaxial tomography (PETT) in biomedical sciences. This paper describes problems and progress in the synthesis of short-lived positron emitter (/sup 11/C, /sup 18/F, /sup 13/N) labelled tracers for PETT. Synthesis of labelled sugars, amino acids, and neurotransmitter receptors (pimozide and spiroperidol tagged with /sup 11/C) is discussed in particular. (DLC)

  13. Resonances in low-energy positron-alkali scattering

    NASA Technical Reports Server (NTRS)

    Horbatsch, M.; Ward, S. J.; Mceachran, R. P.; Stauffer, A. D.

    1990-01-01

    Close-coupling calculations were performed with up to five target states at energies in the excitation threshold region for positron scattering from Li, Na and K. Resonances were discovered in the L = 0, 1 and 2 channels in the vicinity of the atomic excitation thresholds. The widths of these resonances vary between 0.2 and 130 MeV. Evidence was found for the existence of positron-alkali bound states in all cases.

  14. Positron annihilation in TiBe/sub 2/

    SciTech Connect

    Manuel, A.A.; Hoffmann, L.; Singh, A.K.; Jarlborg, T.; Peter, M.; Smith, J.L.; Fisk, Z.; Pecora, L.M.; Ehrlich, A.C.

    1988-01-01

    We report positron annihilation measurements on TiBe/sub 2/. Calculations using LMTO band structure method are also presented. The good agreement with the experimental data leads to the conclusion that the unusual magnetic properties of this compound can be well explained in terms of its electronic structure. A reconstruction of the electron-positron momentum distribution from calculated and measured 2D-ACPAR is discussed. 10 refs., 3 figs.

  15. A slow positron beam generator for lifetime studies

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Eftekhari, Abe; St.clair, Terry L.

    1989-01-01

    A slow positron beam generator using well-annealed polycrystalline tungsten moderators and a Na-22 positron source was developed. A 250 micro c source, deposited on a 2.54 micron thick aluminized mylar, is sandwiched between two (2.54 cm x 2.54 cm x 0.0127 cm) tungsten pieces. Two (2.54 cm x 2.54 cm x t cm) test polymer films insulate the two tungsten moderator pieces from the aluminized mylar source holder (t=0.00127 to 0.0127). A potential difference of 10 to 100 volts--depending on the test polymer film thickness (t)--is applied between the tungsten pieces and the source foil. Thermalized positrons diffusing out of the moderator pieces are attracted to the source foil held at an appropriate potential below the moderator pieces. These positrons have to pass through the test polymer films before they can reach the source foil. The potential difference between the moderator pieces and the aluminized mylar is so adjusted as to force the positrons to stop in the test polymer films. Thus the new generator becomes an effective source of positrons for assaying thin polymer films for their molecular morphology.

  16. Si nanocrystals and nanocrystal interfaces studied by positron annihilation

    NASA Astrophysics Data System (ADS)

    Kujala, J.; Slotte, J.; Tuomisto, F.; Hiller, D.; Zacharias, M.

    2016-10-01

    Si nanocrystals embedded in a SiO 2 matrix were studied with positron annihilation and photoluminescence spectroscopies. Analysis of the S- and W-parameters for the sample annealed at 800 °C reveals a positron trap at the interface between the amorphous nanodots and the surrounding matrix. Another trap state is observed in the 1150 °C heat treated samples where nanodots are in a crystalline form. Positrons are most likely trapped to defects related to dangling bonds at the surface of the nanocrystals. Passivation of the samples results on one hand in the decrease of the S-parameter implying a decrease in the open volume of the interface state and, on the other hand, in the strengthening of the positron annihilation signal from the interface. The intensity of the photoluminescence signal increases with the formation of the nanocrystals. Passivation of samples strengthens the photoluminescence signal, further indicating a successful deactivation of luminescence quenching at the nanocrystal surface. Strengthening of the positron annihilation signal and an increase in the photoluminescence intensity in passivated silicon nanocrystals suggests that the positron trap at the interface does not contribute to a significant extent to the exciton recombination in the nanocrystals.

  17. Positron sensing of distribution of defects in depth materials

    NASA Astrophysics Data System (ADS)

    Kupchishin, A. I.; Kupchishin, A. A.; Voronova, N. A.; Kirdyashkin, V. I.

    2016-02-01

    It was developed a non-destructive method of positron sensing, which allows to determine the distribution of defects in the depth of the material. From the analysis we can conclude that the angular distribution curves of annihilation photons (well as and on the characteristics in experiments on the lifetime, 3γ - angular correlation, Doppler effect) is influenced by three main factors: a) The distribution of defects in the depth of the material, their dimensions as well as parameters of the interaction of positrons with defects. With increasing the concentration of defects the intensity Jγ(a, ξ) varies more; b) Modification of the energy spectrum of slow positrons due to the influence of defects, wherein the spectrum of positrons becomes softer, and the average energy of the positron annihilation is reduced; c) Deformation of the momentum distribution of the electrons in the region of defect. The energy spectrum of electrons is also becomes softer, and the average energy of the electrons (on which positrons annihilate) is less. The experimentally were measured spectra of photons in the zone of annihilation and were calculated the distribution of defects in depth for a number of metals.

  18. Positron annihilation study on hafnium metals given various treatments

    SciTech Connect

    Min, Duck Ki; Kang, Myung Soo ); Yoon, Young Ku )

    1993-08-01

    The positron annihilation technique that enables measurements of positron lifetime, two-photon angular correlation and Doppler broadening due to annihilation radiation has been established for studies of the electronic configuration and defect properties in solids. In metals, positrons can be trapped at vacancies and their agglomerates as well as at dislocations, but not at interstitials. Because of these interactions, the positron annihilation method can be applied to studies of the behavior of dislocations during annealing of plastically deformed metals. Furthermore, it is possible by measurements of annihilation characteristics to identify defects such as vacancies, dislocations and vacancy-clusters, and to determine spatial dimensions of defects. In this work, positron annihilation measurements for annealed, cold worked, annealed and then quenched, and cold worked and then cathodically hydrogen charged hafnium specimens were made to obtain information on (a) positron annihilation characteristics of hafnium metal, (b) role of vacancy-type defects on hydrogen charging, (c) defects produced during hydrogen charging and (d) recovery of lattice defects in hafnium and effects of hydrogen on defects recovery upon annealing.

  19. PhytoBeta imager: a positron imager for plant biology

    SciTech Connect

    Weisenberger, Andrew G; Lee, Seungjoon; McKisson, John; McKisson, J E; Xi, Wenze; Zorn, Carl; Reid, Chantal D; Howell, Calvin R; Crowell, Alexander S; Cumberbatch, Laurie; Fallin, Brent; Stolin, Alexander; Smith, Mark F

    2012-06-01

    Several positron emitting radioisotopes such as 11C and 13N can be used in plant biology research. The 11CO2 tracer is used to facilitate plant biology research toward optimization of plant productivity, biofuel development and carbon sequestration in biomass. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using 11CO2. Because plants typically have very thin leaves, little medium is present for the emitted positrons to undergo an annihilation event. The emitted positrons from 11C (maximum energy 960 keV) could require up to approximately 4 mm of water equivalent material for positron annihilation. Thus many of the positrons do not annihilate inside the leaf, resulting in limited sensitivity for PET imaging. To address this problem we have developed a compact beta-positive, beta-minus particle imager (PhytoBeta imager) for 11CO2 leaf imaging. The detector is based on a Hamamatsu H8500 position sensitive photomultiplier tube optically coupled via optical grease to a 0.5 mm thick Eljen EJ-212 plastic scintillator. The detector is equipped with a flexible arm to allow its placement and orientation over or under the leaf to be studied while maintaining the leaf's original orientation. To test the utility of the system the detector was used to measure carbon translocation in a leaf of the spicebush (Lindera benzoin) under two transient light conditions.

  20. Positron Injector Accelerator and RF System for the ILC

    SciTech Connect

    Wang, J.W.; Adolphsen, C.; Bharadwaj, V.; Bowden, G.; Jongewaard, E.; Li, Z.; Miller, R.; Sheppard, J.C.; /SLAC

    2007-03-28

    Due to the extremely high energy deposition from positrons, electrons, photons and neutrons behind the positron target, and because a solenoid is required to focus the large emittance positron beam, the 1.3 GHz preaccelerator has to use normal conducting structures up to energy of 400 MeV. There are many challenges in the design of the normal-conducting portion of the ILC positron injector system such as obtaining high positron yield with required emittance, achieving adequate cooling with the high RF and particle loss heating, and sustaining high accelerator gradients during millisecond-long pulses in a strong magnetic field. Considering issues of feasibility, reliability and cost savings for the ILC, the proposed design for the positron injector contains both standing-wave (SW) and traveling-wave (TW) L-band accelerator structures. A short version of the new type of the SW section is under fabrication and testing. An updated status report is given. This paper also covers acceleration vs. deceleration for pre-accelerator sections, SW vs. TW structures, as well as longitudinal matching from target to linac and linac to damping ring.

  1. Positron dynamics in surface-charged solid argon

    SciTech Connect

    Jorgensen, L.V.; Merrison, J.P.; Deutch, B.I.; Charlton, M.; Jones, G.O.

    1995-10-15

    Studies have been made of the reemission of positrons incident at low energies upon solid argon to which electric fields were applied by charging an overlayer of molecular oxygen. An enhancement in positron reemission was observed which reached a maximum for an applied field of around 7 kV mm{sup {minus}1}. At this field strength the same yield was observed for implantation energies ranging from 1 to 10 keV, consistent with enhancement due to field-induced positron drift to the exit surface. At higher electric fields, the observed gradual decrease in enhancement was attributed to the heating of the positron energy distribution above the positronium formation threshold. Quantitative agreement with our experimental results has been obtained using a Monte Carlo simulation from which estimates for the positron diffusion length and mobility of 1.7(+2.0,{minus}0.4) {mu}m and 4.7(+2.9,{minus}0.4){times}10{sup {minus}3} m{sup 2} V{sup {minus}1} s{sup {minus}1}, respectively, have been derived. This model was also able to successfully reproduce previous results obtained using surface-charged argon {beta}{sup +} moderators. An abrupt and almost complete reduction in positron reemission was observed for applied surface potentials above a value which showed a weak dependence on film thickness.

  2. PEPPo: Using a Polarized Electron Beam to Produce Polarized Positrons

    SciTech Connect

    Adeyemi, Adeleke H.

    2015-09-01

    Polarized positron beams have been identified as either an essential or a significant ingredient for the experimental program of both the present and next generation of lepton accelerators (JLab, Super KEK B, ILC, CLIC). An experiment demonstrating a new method for producing polarized positrons has been performed at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. The PEPPo (Polarized Electrons for Polarized Positrons) concept relies on the production of polarized e⁻/e⁺ pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. PEPPo demonstrated the effective transfer of spin-polarization of an 8.2 MeV/c polarized (P~85%) electron beam to positrons produced in varying thickness tungsten production targets, and collected and measured in the range of 3.1 to 6.2 MeV/c. In comparison to other methods this technique reveals a new pathway for producing either high-energy or thermal polarized positron beams using a relatively low polarized electron beam energy (~10MeV) .This presentation will describe the PEPPo concept, the motivations of the experiment and high positron polarization achieved.

  3. Positron-attachment to small molecules: Vibrational enhancement of positron affinities with configuration interaction level of multi-component molecular orbital approach

    SciTech Connect

    Tachikawa, Masanori

    2015-12-31

    To theoretically demonstrate the binding of a positron to small polarized molecules, we have calculated the vibrational averaged positron affinity (PA) values along the local vibrational contribution with the configuration interaction level of multi-component molecular orbital method. This method can take the electron-positron correlation contribution into account through single electronic - single positronic excitation configurations. The PA values are enhanced by including the local vibrational contribution from vertical PA values due to the anharmonicity of the potential.

  4. Hypoxia imaging agents labeled with positron emitters.

    PubMed

    Hoigebazar, Lathika; Jeong, Jae Min

    2013-01-01

    Imaging hypoxia using positron emission tomography (PET) is of great importance for therapy of cancer. [(18)F]Fluoromisonidazole (FMISO) was the first PET agent for hypoxia imaging, and various radiolabeled nitroimidazole derivatives such as [(18)F]fluoroerythronitroimidazole (FETNIM), [(18)F]1-α-D: -(2-deoxy-2-fluoroarabinofuranosyl)-2-nitroimidazole (FAZA), [(18)F]2-(2-nitro-1H-imidazol-1-yl)-N-(2,2,3,3,3-pentafluoropropyl) acetamide (EF-5), and [(18)F]fluoroetanidazole (FETA) have been developed successively. To overcome the high cost of cyclotron installation, (68)Ga-labeled nitroimidazole derivatives also have been developed. Another important hypoxia imaging agent is (64)Cu-diacetyl-bis(N (4)-methylthiosemicarbazone) ((64)Cu-ATSM), which can distribute in cancer tissue rapidly due to high lipophilicity. However, its application is limited due to high cost of radionuclide production. Although various hypoxia imaging agents have been reported and tested, hypoxia PET images still have to be improved, because of the low blood flow in hypoxic tissues and resulting low uptake of the agents.

  5. SLC positron damping ring optics design

    SciTech Connect

    Delahaye, J.P.; Rivkin, L.

    1984-12-01

    The basic SLAC Linear Collider operation scheme assumes the use of two damping rings, one for the e/sup -/, one for the e/sup +/, in order to reduce the colliding beam normalized emittances to 30..pi.. ..mu..radm hence raising the corresponding luminosity by a factor 170. The e/sup -/ damping ring which optics was designed by H. Wiedemann, has been extensively studied and modelled since it's completion at the end of 1982. The e/sup +/ damping ring to be built soon will be based on the same design except for some modifications resulting from the studies on the e/sup -/ damping ring which clearly pointed out two major optics weak points: the extracted normalized emittances are 30 to 60% bigger than the design values, which already left no margin for unavoidable blow-up between the damping rings and the SLC interaction point, and the chromaticity correction based on distributed sextupole components provided by shaping the ends of the bending magnet poles was insufficient. Moreover the QDI quadrupoles introduce a strong coupling between transverse planes due to an undesirable skew component. The present note describes the basic modifications of the ring lattice and main equipment positions in order to improve the first two points in the Positron Damping Ring. The QDI quadrupole design has already been modified and magnets of a new type will be implemented in both damping rings.

  6. Low-energy positron scattering by pyrimidine

    SciTech Connect

    Barbosa, Alessandra Souza; Pastega, Diego F.; Bettega, Márcio H. F.

    2015-12-28

    This work reports elastic integral and differential cross sections for positron collisions with pyrimidine, for energies up to 20 eV. The cross sections were computed with the Schwinger multichannel method in the static plus polarization approximation. We also employed the Born closure procedure to account for the long range potential due to the permanent dipole moment of the molecule. Our results are compared with the experimental total cross section of Zecca et al. [J. Phys. B 43, 215204 (2010)], the experimental grand-total, quasi-elastic integral and differential cross section of Palihawadana et al. [Phys. Rev. A 88, 12717 (2013)]. We also compare our results with theoretical integral and differential cross sections obtained by Sanz et al. [Phys. Rev. A 88, 62704 (2013)] with the R-matrix and the independent atom model with screening-corrected additivity rule methods, and with the results computed by Franz and Gianturco [Phys. Rev. A 88, 042711 (2013)] using model correlation-polarization potentials. The agreement between the theory and the experiment is encouraging.

  7. Data acquisition with a positron emission tomograph

    SciTech Connect

    Freifelder, R.; Karp, J.S.

    1997-12-31

    Positron Emission Tomography (PET) is a clinical imaging modality used in Nuclear Medicine. PET measures functionality rather than anatomical features and is therefore invaluable in the treatment of diseases which are characterized by functional changes in organs rather than anatomical changes. Typical diseases for which PET is used are cancer, epilepsy, and heart disease. While the scanners are not very complex, the performance demands on the devices are high. Excellent spatial resolution, 4-5 mm, and high sensitivity are key to maintaining high image quality. Compensation or suppression of scattered radiation is also necessary for good image quality. The ability to acquire data under high counting rates is also necessary in order to minimize the injected dose to the patient, minimize the patient`s time in the scanner, and finally to minimize blurring due to patient motion. We have adapted various techniques in our data acquisition system which will be reported on in this talk. These include pulse clipping using lumped delay lines, flash ADCs with short sampling time, the use of a local positioning algorithm to limit the number of data words being used in subsequent second level software triggers and calculations, and finally the use of high speed dedicated calculator boards for on-line rebinning and reduction of the data. Modifications to the system to allow for transmission scanning will also be discussed.

  8. Positron emission tomography in generalized seizures

    SciTech Connect

    Theodore, W.H.; Brooks, R.; Margolin, R.; Patronas, N.; Sato, S.; Porter, R.J.; Mansi, L.; Bairamian, D.; DiChiro, G.

    1985-05-01

    The authors used /sup 18/F-fluorodeoxyglucose (FDG) positron emission tomography (PET) to study nine patients with clinical absence or generalized seizures. One patient had only absence seizures, two had only generalized tonic-clonic seizures, and six had both seizure types. Interictal scans in eight failed to reveal focal or lateralized hypometabolism. No apparent abnormalities were noted. Two patients had PET scans after isotope injection during hyperventilation-induced generalized spike-wave discharges. Diffusely increased metabolic rates were found in one compared with an interictal scan, and in another compared with control values. Another patient had FDG injected during absence status: EEG showed generalized spike-wave discharges (during which she was unresponsive) intermixed with slow activity accompanied by confusion. Metabolic rates were decreased, compared with the interictal scan, throughout both cortical and subcortical structures. Interictal PET did not detect specific anatomic regions responsible for absence seizure onset in any patient, but the results of the ictal scans did suggest that pathophysiologic differences exist between absence status and single absence attacks.

  9. Amorphous silicon detectors in positron emission tomography

    SciTech Connect

    Conti, M. Lawrence Berkeley Lab., CA ); Perez-Mendez, V. )

    1989-12-01

    The physics of the detection process is studied and the performances of different Positron Emission Tomography (PET) system are evaluated by theoretical calculation and/or Monte Carlo Simulation (using the EGS code) in this paper, whose table of contents can be summarized as follows: a brief introduction to amorphous silicon detectors and some useful equation is presented; a Tantalum/Amorphous Silicon PET project is studied and the efficiency of the systems is studied by Monte Carlo Simulation; two similar CsI/Amorphous Silicon PET projects are presented and their efficiency and spatial resolution are studied by Monte Carlo Simulation, light yield and time characteristics of the scintillation light are discussed for different scintillators; some experimental result on light yield measurements are presented; a Xenon/Amorphous Silicon PET is presented, the physical mechanism of scintillation in Xenon is explained, a theoretical estimation of total light yield in Xenon and the resulting efficiency is discussed altogether with some consideration of the time resolution of the system; the amorphous silicon integrated electronics is presented, total noise and time resolution are evaluated in each of our applications; the merit parameters {epsilon}{sup 2}{tau}'s are evaluated and compared with other PET systems and conclusions are drawn; and a complete reference list for Xenon scintillation light physics and its applications is presented altogether with the listing of the developed simulation programs.

  10. An Alternative Approach to Understanding the Observed Positron Fraction

    NASA Astrophysics Data System (ADS)

    Israel, Martin H.

    2014-10-01

    Space-based observations by PAMELA (Adriani et al., Nature 458, 607, 2009), Fermi-LAT (Ackerman et al., Phys. Rev. Lett. 105, 01103, 2012), and AMS (Aguilar et al., Phys. Rev. Lett. 110, 141102, 2013) have demonstrated that the positron fraction (e+/total-e) increases with increasing energy above about 10 GeV. According to the propagation model for Galactic cosmic rays in widespread use (Moskalenko & Strong, Astrophys. J. 493, 693, 1998), the production of secondary positrons from interaction of cosmic-ray protons and heavier nuclei with the interstellar medium gives a generally falling positron fraction between 10 and 100 GeV, with secondary positrons accounting for only ˜20 % of the observed positron fraction at 100 GeV; so some other physical phenomena have been proposed to explain the data. An alternative approach to interpreting the positron observations is to consider these data as presenting an opportunity for re-examining models of Galactic cosmic-ray propagation. Following release of the PAMELA data, three groups published propagation models (Shaviv, et al., Phys. Rev. Lett. 103, 111302, 2009, Cowsik and Burch, Phys. Rev. D. 82, 023009, 2010, Katz et al., Mon. Not. R. Aston. Soc. 405, 1458 2010) in which the observed positron fraction is explained entirely by secondary positrons produced in the interstellar medium. In May of this year, stimulated by the AMS extension of the positron data to higher energy with excellent statistics, two of those groups presented further development of their calculations (Cowsik et al. 2013, Blum et al. 2013), again concluding that the observed positrons can be understood as secondaries. None of the authors of these five papers was registered for the 33rd International Cosmic Ray Conference (ICRC). Although I am not an author of any of these papers, I have some close familiarity with one of these recent papers, so the conference organizers invited me to bring this alternative approach to the attention of the conference. The

  11. Studies of discrete symmetries in a purely leptonic system using the Jagiellonian Positron Emission Tomograph

    NASA Astrophysics Data System (ADS)

    Moskal, P.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kamińska, D.; Khreptak, O.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedńwiecka, M.; Raczyński, L.; Rudy, Z.; Silarski, M.; Smyrski, J.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.

    2016-11-01

    Discrete symmetries such as parity (P), charge-conjugation (C) and time reversal (T) are of fundamental importance in physics and cosmology. Breaking of charge conjugation symmetry (C) and its combination with parity (CP) constitute necessary conditions for the existence of the asymmetry between matter and antimatter in the observed Universe. The presently known sources of discrete symmetries violations can account for only a tiny fraction of the excess of matter over antimatter. So far CP and T symmetries violations were observed only for systems involving quarks and they were never reported for the purely leptonic objects. In this article we describe briefly an experimental proposal for the test of discrete symmetries in the decays of positronium atom which is made exclusively of leptons. The experiments are conducted by means of the Jagiellonian Positron Emission Tomograph (J-PET) which is constructed from strips of plastic scintillators enabling registration of photons from the positronium annihilation. J-PET tomograph together with the positronium target system enable to measure expectation values for the discrete symmetries odd operators constructed from (i) spin vector of the ortho-positronium atom, (ii) momentum vectors of photons originating from the decay of positronium, and (iii) linear polarization direction of annihilation photons. Linearly polarized positronium will be produced in the highly porous aerogel or polymer targets, exploiting longitudinally polarized positrons emitted by the sodium 22Na isotope. Information about the polarization vector of orthopositronium will be available on the event by event basis and will be reconstructed from the known position of the positron source and the reconstructed position of the orthopositronium annihilation. In 2016 the first tests and calibration runs are planned, and the data collection with high statistics will commence in the year 2017.

  12. Plasma and trap-based techniques for science with positrons

    NASA Astrophysics Data System (ADS)

    Danielson, J. R.; Dubin, D. H. E.; Greaves, R. G.; Surko, C. M.

    2015-01-01

    In recent years, there has been a wealth of new science involving low-energy antimatter (i.e., positrons and antiprotons) at energies ranging from 102 to less than 10-3 eV . Much of this progress has been driven by the development of new plasma-based techniques to accumulate, manipulate, and deliver antiparticles for specific applications. This article focuses on the advances made in this area using positrons. However, many of the resulting techniques are relevant to antiprotons as well. An overview is presented of relevant theory of single-component plasmas in electromagnetic traps. Methods are described to produce intense sources of positrons and to efficiently slow the typically energetic particles thus produced. Techniques are described to trap positrons efficiently and to cool and compress the resulting positron gases and plasmas. Finally, the procedures developed to deliver tailored pulses and beams (e.g., in intense, short bursts, or as quasimonoenergetic continuous beams) for specific applications are reviewed. The status of development in specific application areas is also reviewed. One example is the formation of antihydrogen atoms for fundamental physics [e.g., tests of invariance under charge conjugation, parity inversion, and time reversal (the CPT theorem), and studies of the interaction of gravity with antimatter]. Other applications discussed include atomic and materials physics studies and the study of the electron-positron many-body system, including both classical electron-positron plasmas and the complementary quantum system in the form of Bose-condensed gases of positronium atoms. Areas of future promise are also discussed. The review concludes with a brief summary and a list of outstanding challenges.

  13. Positron Emission Mammography with Multiple Angle Acquisition

    SciTech Connect

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FDG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three- dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  14. Positron Emission Mammography with Multiple Angle Acquisition

    SciTech Connect

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FbG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three-dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  15. Effect of positron range on spatial resolution.

    PubMed

    Phelps, M E; Hoffman, E J; Huang, S C; Ter-Pogossian, M M

    1975-07-01

    The effect of beta+ range on spatial resolution of imaging systems employing the detection of 511-keV annihilation radiation was determined by measuring the variation in the line-spread functions (LSFs) of positron-emitting radionuclides of 64Cu, 11C, and 15O as compared with the 514-keV gamma-ray emitter 85Sr. These radionuclides have maximum beta+ energies of 0.656, 0.960, and 1.72 MeV, respectively. The LSFs were measured in a tissue-equivalent phantom with high-resolution (approximately 2.4 mm FWHM) and low-resolution (approximately 8.8 mm FWHM) straightbore collimators coupled to a NaI(Tl) detector. Theoretical LSFs for the beta+ ranges were also calculated and convolved with the 85Sr LSF to yield the predicted LSFs for 11C and 15O. The high-resolution study showed a 0% and 2.3% increase in the full-width half-maximum (FWHM) and full-width tenth-maximum (FWO.1M) for the low-energy beta+ of 64Cu and a 37% (FWHM) and 52% (FWO.1M) increase for the high energy beta+ of 15O as compared with 85Sr. However, when the system resolution was decreased to 8.8 mm FWHM, the 64Cu showed no change at FWHM or FWO.1M and the 15O showed a 2.3% (FWHM) and 7.8% (FWO.1M) relative to 85Sr. The predicted LSFs were in good agreement with the experimental. These data indicate that the effect of beta+ range on spatial resolution is minimal unless the beta+ energy is larger than or equal to 1.5 MeV and the system resolution is on the order of a few millimeters.

  16. Acceleration of positrons in supernova shocks

    NASA Technical Reports Server (NTRS)

    Ellison, Donald C.

    1992-01-01

    During this project we investigated the acceleration of leptons (electrons and positrons) in collisionless shock waves. In particular, we were interested in how leptons are accelerated in the blast waves existing in the remnants of supernova explosions. Supernova remnants (SNRs) have long been considered as the most likely source of galactic cosmic rays but no definite connection between SNRs and the cosmic rays seen at earth can be made. Only by understanding lepton acceleration in shocks can the rich SNR data base be properly used to understand cosmic ray origins. Our project was directed at the neglected aspects of lepton acceleration. We showed that the efficiency of lepton acceleration depended critically on the lepton injection energy. We showed that, even when infection effects are not important, that proton and lepton distribution functions produced by shocks are quite different in the critical energy range for producing the observed synchrotron emission. We also showed that transrelativistic effects produced proton spectra that were not in agreement with standard results from radio observations, but that the lepton spectra were, in fact, consistent with observations. We performed simulations of relativistic shocks (shocks where the flow speed is a sizable fraction of the speed of light) and discovered some interesting effects. We first demonstrated the power of the Monte Carlo technique by determining the shock jump conditions in relativistic shocks. We then proceeded to determine how relativistic shocks accelerate particles. We found that nonlinear relativistic shocks treat protons and leptons even more differently than nonrelativistic shocks. The transrelativistic effects on the shock structure from the heavy ion component reduces the lepton acceleration to a tiny fraction of the ion acceleration. This effect is dramatic even if high energy leptons (many times thermal energy) are injected, and was totally unexpected. Our results have important

  17. Thermonuclear Supernovae: Probing Magnetic Fields by Positrons and Late-time IR Line Profiles

    NASA Astrophysics Data System (ADS)

    Penney, R.; Hoeflich, P.

    2014-11-01

    We show the importance of γ and positron transport for the formation of late-time spectra in Type Ia supernovae (SNe Ia). The goal is to study the imprint of magnetic fields (B) on late-time IR line profiles, particularly the [Fe II] feature at 1.644 μm, which becomes prominent two to three months after the explosion. As a benchmark, we use the explosion of a Chandrasekhar mass (M Ch) white dwarf (WD) and, specifically, a delayed detonation model that can reproduce the light curves and spectra for a Branch-normal SN Ia. We assume WDs with initial magnetic surface fields between 1 and 109 G. We discuss large-scale dipole and small-scale magnetic fields. We show that positron transport effects must be taken into account for the interpretation of emission features starting at about one to two years after maximum light, depending on the size of B. The [Fe II] line profile and its evolution with time can be understood in terms of the overall energy input by radioactive decay and the transition from a γ-ray to a positron-dominated regime. We find that the [Fe II] line at 1.644 μm can be used to analyze the overall chemical and density structure of the exploding WD up to day 200 without considering B. At later times, positron transport and magnetic field effects become important. After about day 300, the line profile allows one to probe the size of the B-field. The profile becomes sensitive to the morphology of B at about day 500. In the presence of a large-scale dipole field, a broad line is produced in M Ch mass explosions that may appear flat-topped or rounded depending on the inclination at which the SN is observed. Small or no directional dependence of the spectra is found for small-scale B. We note that narrow-line profiles require central 56Ni as shown in our previous studies. Persistent broad-line, flat-topped profiles require high-density burning, which is the signature of a WD close to M Ch. Good time coverage is required to separate the effects of optical

  18. A new look at the cosmic ray positron fraction

    NASA Astrophysics Data System (ADS)

    Boudaud, M.; Aupetit, S.; Caroff, S.; Putze, A.; Belanger, G.; Genolini, Y.; Goy, C.; Poireau, V.; Poulin, V.; Rosier, S.; Salati, P.; Tao, L.; Vecchi, M.

    2015-03-01

    Context. The positron fraction in cosmic rays has recently been measured with improved accuracy up to 500 GeV, and it was found to be a steadily increasing function of energy above ~10 GeV. This behaviour contrasts with standard astrophysical mechanisms, in which positrons are secondary particles, produced in the interactions of primary cosmic rays during their propagation in the interstellar medium. The observed anomaly in the positron fraction triggered a lot of excitement, as it could be interpreted as an indirect signature of the presence of dark matter species in the Galaxy, the so-called weakly interacting massive particles (WIMPs). Alternatively, it could be produced by nearby sources, such as pulsars. Aims: These hypotheses are probed in light of the latest AMS-02 positron fraction measurements. As regards dark matter candidates, regions in the annihilation cross section to mass plane, which best fit the most recent data, are delineated and compared to previous measurements. The explanation of the anomaly in terms of a single nearby pulsar is also explored. Methods: The cosmic ray positron transport in the Galaxy is described using a semi-analytic two-zone model. Propagation is described with Green functions as well as with Bessel expansions. For consistency, the secondary and primary components of the positron flux are calculated together with the same propagation model. The above mentioned explanations of the positron anomaly are tested using χ2 fits. The numerical package MicrOMEGAs is used to model the positron flux generated by dark matter species. The description of the positron fraction from conventional astrophysical sources is based on the pulsar observations included in the Australia Telescope National Facility (ATNF) catalogue. Results: The masses of the favoured dark matter candidates are always larger than 500 GeV, even though the results are very sensitive to the lepton flux. The Fermi measurements point systematically to much heavier

  19. Resonances and Bound States in Positron Annihilation on Molecules

    NASA Astrophysics Data System (ADS)

    Surko, C. M.

    2007-10-01

    Positron annihilation is important in such diverse areas as study of metabolic processes in the human brain and the characterization of materials. Annihilation on molecules has been a subject of keen interest for decades. In particular, annihilation rates can be orders of magnitude greater than those expected for simple collisions. Recent results put our understanding of many aspects of this long-standing problem on a firm footing. We now understand that the annihilation proceeds by vibrational Feshbach resonances (VFR). A prerequisite for the existence of these VFR is that the positron binds to the target. The annihilation energy spectra provide the best measures to date of positron binding energies. Predictions of a new theory of VFR-enhanced annihilation in small molecules (methyl halides) [1] show excellent, quantitative agreement with experiment. New data and analyses for larger molecules (e.g., hydrocarbons with more than two carbon atoms) show that annihilation rates depend strongly on the number of vibrational degrees of freedom but, surprisingly, only weakly on positron binding energy. This places important constraints on theories of annihilation in these molecules. Results for second bound (i.e., positronically excited) states and overtone and combination-mode VFR, as well as outstanding questions, will also be discussed. This work is done in collaboration with Jason Young. [1] G. F. Gribakin and C. M. R. Lee, Phys. Rev. Lett. 97, 193201 (2006).

  20. The effect of direct positron production on relativistic feedback rates

    NASA Astrophysics Data System (ADS)

    Vodopiyanov, I. B.; Dwyer, J. R.; Lucia, R. J.; Cramer, E. S.; Arabshahi, S.; Rassoul, H.

    2013-12-01

    Relativistic feedback produces a self-sustaining runaway electron discharge via the production of backward propagating positrons and back-scattered x-rays. To date, only positrons created from pair-production by gamma-rays interacting with the air have been considered. In contrast, direct pair-production involves the creation of electron-positron pairs directly from the interaction of energetic runaway electrons with nuclei, and so it does not require the generation of bremsstrahlung gamma-rays. For high electric fields, where the runaway electron avalanche length scales are short, pair-production involving bremsstrahlung gamma-rays makes a smaller contribution to the total relativistic feedback rates than at lower fields, since both the bremsstrahlung interaction and the pair-production need to occur over a short length. On the other hand, for high fields, because direct positron production only involves one interaction, it may make a significant contribution to relativistic feedback rates in some cases. In this poster, we shall present the direct positron production cross-sections and calculate the effects on the relativistic feedback rates due to this process.

  1. Possibilities with pulsed polarized high density slow positrons

    NASA Astrophysics Data System (ADS)

    Mills, A. P., Jr.

    2014-04-01

    A particularly bright and intense polarized slow positron beam could be formed from isotopically enriched 79Kr produced at a reactor. After moderation with solid Ne, accumulation, compression, and bunching, this type of positron beam would enable a number of experiments including: (1) Long term storage of a neutral polarized electron-positron plasma in a cold box; (2) Pulsed e+ ACAR with a pulsed magnet to measure Fermi surfaces of paramagnetic metals; (3) Single shot measurements of positron annihilation in laser-imploding plasmas; (4) Study of a spin-polarized positronium gas at a density around that of ordinary air to produce a Ps Bose-Einstein condensate at room temperature; (5) High energy polarized positron channelling experiments to study polarized electron spatial wave functions in ferromagnets; and (6) Study of supersonic free expansion spin polarized BEC Ps jets formed from, for example, 1011 m=1 triplet Ps atoms created within an open ended 1 μm diameter cylindrical cavity 100 μm in length.

  2. Interpretation of AMS-02 electrons and positrons data

    SciTech Connect

    Mauro, M. Di; Donato, F.; Fornengo, N.; Vittino, A.; Lineros, R. E-mail: donato@to.infn.it E-mail: rlineros@ific.uv.es

    2014-04-01

    We perform a combined analysis of the recent AMS-02 data on electrons, positrons, electrons plus positrons and positron fraction, in a self-consistent framework where we realize a theoretical modeling of all the astrophysical components that can contribute to the observed fluxes in the whole energy range. The primary electron contribution is modeled through the sum of an average flux from distant sources and the fluxes from the local supernova remnants in the Green catalog. The secondary electron and positron fluxes originate from interactions on the interstellar medium of primary cosmic rays, for which we derive a novel determination by using AMS-02 proton and helium data. Primary positrons and electrons from pulsar wind nebulae in the ATNF catalog are included and studied in terms of their most significant (while loosely known) properties and under different assumptions (average contribution from the whole catalog, single dominant pulsar, a few dominant pulsars). We obtain a remarkable agreement between our various modeling and the AMS-02 data for all types of analysis, demonstrating that the whole AMS-02 leptonic data admit a self-consistent interpretation in terms of astrophysical contributions.

  3. Four-dimensional positron age-momentum correlation

    NASA Astrophysics Data System (ADS)

    Ackermann, Ulrich; Löwe, Benjamin; Dickmann, Marcel; Mitteneder, Johannes; Sperr, Peter; Egger, Werner; Reiner, Markus; Dollinger, Günther

    2016-11-01

    We have performed first four-dimensional age-momentum correlation (4D-AMOC) measurements at a pulsed high intensity positron micro beam and determined the absolute value of the three-dimensional momentum of the electrons annihilating with the positrons in coincidence with the positron age in the sample material. We operated two position sensitive detectors in coincidence to measure the annihilation radiation: a pixelated HPGe-detector and a microchannel plate image intensifier with a CeBr3 scintillator pixel array. The transversal momentum resolution of the 4D-AMOC setup was measured to be about 17 × 10-3 {m}0c (FWHM) and was circa 3.5 times larger than the longitudinal momentum resolution. The total time resolution was 540 ps (FWHM). We measured two samples: a gold foil and a carbon tape at a positron implantation energy of 2 keV. For each sample discrete electron momentum states and their respective positron lifetimes were extracted.

  4. High-intensity positron microprobe at Jefferson Lab

    SciTech Connect

    Golge, Serkan; Vlahovic, Branislav; Wojtsekhowski, Bogdan B.

    2014-06-19

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity slow-positron production source with a projected intensity on the order of 1010 e+/s. Reaching this intensity in our design relies on the transport of positrons (T+ below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. The performance of the integrated beamline has been verified through computational studies. The computational results include Monte Carlo calculations of the optimized electron/positron beam energies, converter target thickness, synchronized raster system, transport of the beam from the converter target to the moderator, extraction of the beam from the channel, and moderation efficiency calculations. For the extraction of positrons from the magnetic channel a magnetic field terminator plug prototype has been built and experimental data on the effectiveness of this prototype are presented. The dissipation of the heat away from the converter target and radiation protection measures are also discussed.

  5. Compact Beta Particle/Positron Imager for Plant Biology

    SciTech Connect

    Weisenberger, Andrew; Lee, Seung Joon; McKisson, John; Xi, Wenze; Zorn, Carl; Stolin, Alexander; Majewski, Stan; Majewski, Stanislaw; Howell, Calvin; Crowell, Alec; Smith, Mark

    2011-06-01

    The 11CO2 tracer is used to facilitate plant biology research towards optimization of plant productivity, biofuel development and carbon sequestration in biomass. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using 11CO2. Plants typically have very thin leaves resulting in little medium for the emitted positrons to undergo an annihilation event. For the emitted positron from 11C decay approximately 1mm of water equivalent material is needed for positron annihilation. Thus most of the positrons do not annihilate inside the leaf, resulting in limited sensitivity for PET imaging. To address this problem we have developed a compact beta-positive beta-minus particle (BPBM) imager for 11CO2 leaf imaging. The detector is based on a Hamamatsu H8500 position sensitive photomultiplier tube optically coupled via optical grease and a 3mm thick glass plate to a 0.5mm thick Eljin EJ-212 plastic scintillator. The detector is equipped with a flexible arm to allow its placement and orientation on the leaf of the plant of interest while maintaining the leaf's original orientation. We are planning to utilize the imaging device at the Duke University Phytotron to investigate dynamic carbon transport differences between invasive and native species.

  6. High-intensity positron microprobe at Jefferson Lab

    DOE PAGES

    Golge, Serkan; Vlahovic, Branislav; Wojtsekhowski, Bogdan B.

    2014-06-19

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity slow-positron production source with a projected intensity on the order of 1010 e+/s. Reaching this intensity in our design relies on the transport of positrons (T+ below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. The performance of the integrated beamline has been verified through computational studies. The computational results include Monte Carlo calculations of the optimized electron/positron beam energies, converter target thickness, synchronized raster system, transport of themore » beam from the converter target to the moderator, extraction of the beam from the channel, and moderation efficiency calculations. For the extraction of positrons from the magnetic channel a magnetic field terminator plug prototype has been built and experimental data on the effectiveness of this prototype are presented. The dissipation of the heat away from the converter target and radiation protection measures are also discussed.« less

  7. Vacancy-type defects induced by grinding of Si wafers studied by monoenergetic positron beams

    SciTech Connect

    Uedono, Akira; Yoshihara, Nakaaki; Mizushima, Yoriko; Kim, Youngsuk; Nakamura, Tomoji; Ohba, Takayuki; Oshima, Nagayasu; Suzuki, Ryoichi

    2014-10-07

    Vacancy-type defects introduced by the grinding of Czochralski-grown Si wafers were studied using monoenergetic positron beams. Measurements of Doppler broadening spectra of the annihilation radiation and the lifetime spectra of positrons showed that vacancy-type defects were introduced in the surface region (<98 nm), and the major defect species were identified as (i) relatively small vacancies incorporated in dislocations and (ii) large vacancy clusters. Annealing experiments showed that the defect concentration decreased with increasing annealing temperature in the range between 100 and 500°C. After 600–700°C annealing, the defect-rich region expanded up to about 170 nm, which was attributed to rearrangements of dislocation networks, and a resultant emission of point defects toward the inside of the sample. Above 800°C, the stability limit of those vacancies was reached and they started to disappear. After the vacancies were annealed out (900°C), oxygen-related defects were the major point defects and they were located at <25 nm.

  8. Pretargeted Positron Emission Tomography Imaging That Employs Supramolecular Nanoparticles with in Vivo Bioorthogonal Chemistry.

    PubMed

    Hou, Shuang; Choi, Jin-Sil; Garcia, Mitch Andre; Xing, Yan; Chen, Kuan-Ju; Chen, Yi-Ming; Jiang, Ziyue K; Ro, Tracy; Wu, Lily; Stout, David B; Tomlinson, James S; Wang, Hao; Chen, Kai; Tseng, Hsian-Rong; Lin, Wei-Yu

    2016-01-26

    A pretargeted oncologic positron emission tomography (PET) imaging that leverages the power of supramolecular nanoparticles with in vivo bioorthogonal chemistry was demonstrated for the clinically relevant problem of tumor imaging. The advantages of this approach are that (i) the pharmacokinetics (PKs) of tumor-targeting and imaging agents can be independently altered via chemical alteration to achieve the desired in vivo performance and (ii) the interplay between the two PKs and other controllable variables confers a second layer of control toward improved PET imaging. In brief, we utilized supramolecular chemistry to synthesize tumor-targeting nanoparticles containing transcyclooctene (TCO, a bioorthogonal reactive motif), called TCO⊂SNPs. After the intravenous injection and subsequent concentration of the TCO⊂SNPs in the tumors of living mice, a small molecule containing both the complementary bioorthogonal motif (tetrazine, Tz) and a positron-emitting radioisotope ((64)Cu) was injected to react selectively and irreversibly to TCO. High-contrast PET imaging of the tumor mass was accomplished after the rapid clearance of the unreacted (64)Cu-Tz probe. Our nanoparticle approach encompasses a wider gamut of tumor types due to the use of EPR effects, which is a universal phenomenon for most solid tumors.

  9. Ultra Fine-Grained Metals Prepared by Severe Plastic Deformation: A Positron Annihilation Study

    NASA Astrophysics Data System (ADS)

    Čížek, J.; Procházka, I.; Kužel, R.; Matĕj, Z.; Cherkaska, V.; Cieslar, M.; Smola, B.; Stulíková, I.; Brauer, G.; Anwand, W.; Islamgaliev, R. K.; Kulyasova, O.

    2005-05-01

    Recent investigations of ultra fine-grained metals (Cu, Fe, Ni) performed within a Prague-Rossendorf-Ufa collaboration will be reviewed. The specimens were prepared by severe plastic deformation: the high-pressure torsion and equal channel angular pressing. Positron annihilation spectroscopy was used as the main method including (i) the conventional lifetime and the Doppler broadening measurements with 22Na and (ii) the slow-positron implantation spectroscopy with the Doppler broadening measurement. Other methods were also involved: transmission electron microscopy, X-ray diffraction, and microhardness. First, the mean grain size was determined and defects were identified in the as-deformed materials. Defects concentration and spatial distribution were studied in detail. Dislocations situated in distorted regions along grain boundaries, and a few-vacancy clusters distributed homogeneously inside dislocations-free grains, were observed in the ultra fine-grained Cu, Fe, and Ni. Subsequently, the thermal evolution of the ultra fine-grained structures during isochronal annealing was studied.

  10. Tungsten mesh as positron transmission moderator in a monoenergetic positron beam

    NASA Astrophysics Data System (ADS)

    Weng, H. M.; Ling, C. C.; Beling, C. D.; Fung, S.; Cheung, C. K.; Kwan, P. Y.; Hui, I. P.

    2004-09-01

    The slow positron yield has been measured for various tungsten (W) moderator samples from a 22Na radioactive source. Multi-folded W mesh, W(1 0 0) single crystal foil and W polycrystalline foil samples have been investigated. It is found that the fast to slow conversion efficiency of the W mesh moderator depends on: (1) the annealing pretreatments, (2) the chemical etching duration and (3) the number of the folding layers. With the raw W mesh material having a wire diameter of 20 μm and transmission efficiency of 92.5%, an optimal efficiency of 1.2 × 10 -3 was achieved with 5 min etching duration and a folding number of 12 layers.

  11. A new scheme to accumulate positrons in a Penning-Malmberg trap with a linac-based positron pulsed source

    NASA Astrophysics Data System (ADS)

    Dupré, P.

    2013-03-01

    The Gravitational Behaviour of Antimatter at Rest experiment (GBAR) is designed to perform a direct measurement of the weak equivalence principle on antimatter by measuring the acceleration of anti-hydrogen atoms in the gravitational field of the Earth. The experimental scheme requires a high density positronium (Ps) cloud as a target for antiprotons, provided by the Antiproton Decelerator (AD) - Extra Low Energy Antiproton Ring (ELENA) facility at CERN. The Ps target will be produced by a pulse of few 1010 positrons injected onto a positron-positronium converter. For this purpose, a slow positron source using an electron Linac has been constructed at Saclay. The present flux is comparable with that of 22Na-based sources using solid neon moderator. A new positron accumulation scheme with a Penning-Malmberg trap has been proposed taking advantage of the pulsed time structure of the beam. In the trap, the positrons are cooled by interaction with a dense electron plasma. The overall trapping efficiency has been estimated to be ˜70% by numerical simulations.

  12. Dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons

    SciTech Connect

    Saha, Asit E-mail: prasantachatterjee1@rediffmail.com; Pal, Nikhil; Chatterjee, Prasanta E-mail: prasantachatterjee1@rediffmail.com

    2014-10-15

    The dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons has been investigated in the framework of perturbed and non-perturbed Kadomtsev-Petviashili (KP) equations. Applying the reductive perturbation technique, we have derived the KP equation in electron-positron-ion magnetoplasma with kappa distributed electrons and positrons. Bifurcations of ion acoustic traveling waves of the KP equation are presented. Using the bifurcation theory of planar dynamical systems, the existence of the solitary wave solutions and the periodic traveling wave solutions has been established. Two exact solutions of these waves have been derived depending on the system parameters. Then, using the Hirota's direct method, we have obtained two-soliton and three-soliton solutions of the KP equation. The effect of the spectral index κ on propagations of the two-soliton and the three-soliton has been shown. Considering an external periodic perturbation, we have presented the quasi periodic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas.

  13. Inelastic cross sections for positron scattering from atomic hydrogen

    SciTech Connect

    Weber, M.; Hofmann, A.; Raith, W.; Sperber, W.; Jacobsen, F.; Lynn, K.G.

    1994-12-31

    Positronium formation (Ps) cross sections for positrons impinging on atomic hydrogen were measured in the impact energy range from 13eV to 255eV at the High Intensity Positron (HIP) beam at Brookhaven National Laboratory (BNL). The Ps-formation cross section was found to rise rapidly from the threshold at 6.8eV to a maximum value of (2.98 {plus_minus} 0.18) {times} 10{sup {minus}16} cm{sup 2} for {approx} 15eV positrons. By 75eV it drops below the detection limit of 0.17 {times} 10{sup {minus}16} cm{sup 2} which is the present level of statistical uncertainty. The experiment was modified to enable the measurement of doubly differential scattering cross sections.

  14. Electron- and positron-proton elastic scattering in CLAS

    SciTech Connect

    Weinstein, L. B.

    2009-09-02

    There is a significant disagreement between measurements of the proton electric form factor, G{sup p}{sub E}, using Rosenbluth separations and polarization transfer. This disagreement, if not explained, could pose a fundamental challenge to our understanding of electron scattering or proton structure. Two-photon exchange (TPE) processes, although not fully calculable, are the most likely explanation of this disagreement. We will definitively test this assertion by comparing the electron-proton and positron-proton elastic scattering cross section in the Jefferson Lab CLAS. We will make a mixed identical electron and positron tertiary beam by passing a 5.5 GeV primary electron beam through a radiator to make a photon beam and then passing the photon beam through a converter to make electron-positron pairs. Measuring the elastic cross sections simultaneously using identical lepton beams should significantly reduce systematic uncertainties.

  15. Electron- and positron-proton elastic scattering in CLAS

    SciTech Connect

    L.B. Weinstein

    2009-08-01

    There is a significant disagreement between measurements of the proton electric form factor, G{sup p}{sub E}, using Rosenbluth separations and polarization transfer. This disagreement, if not explained, could pose a fundamental challenge to our understanding of electron scattering or proton structure. Two-photon exchange (TPE) processes, although not fully calculable, are the most likely explanation of this disagreement. We will definitively test this assertion by comparing the electron-proton and positron-proton elastic scattering cross section in the Jefferson Lab CLAS. We will make a mixed identical electron and positron tertiary beam by passing a 5.5 GeV primary electron beam through a radiator to make a photon beam and then passing the photon beam through a converter to make electron-positron pairs. Measuring the elastic cross sections simultaneously using identical lepton beams should significantly reduce systematic uncertainties.

  16. [Positron annihilation lifetime spectrometry (PALS) and its pharmaceutical applications].

    PubMed

    Sebe, István; Szabó, Barnabás; Zelkó, Romána

    2012-01-01

    PALS is one of the most widely used "nuclear probe" techniques for the tracking of the structural characteristics of materials. The method is based on the matter-energy equivalence principle recognized by Einstein: the electrons and positrons as particle-antiparticle pairs disappear in mutual destruction of particles, they annihilate with high-energy gamma-radiation, thus "particle-energy transition" occurs. The properties of the resulting radiation exactly correspond to the relevant properties of the electron and positron preceding the annihilation. Since electrons occur in all types of materials, the phenomenon of positron annihilation can play in any environment; consequently the method can be used for the analysis of each type of materials (crystalline and amorphous, organic and inorganic, biotic and abiotic). The present paper provides an overview of the theoretical physical background, the practical realization and evaluation of methods, their limitations, and summarizes the pharmaceutical applications published in recent years.

  17. Chemical stability of positronic complexes with atoms and atomic ions

    SciTech Connect

    Karl, M.W.; Nakanishi, H.; Schrader, D.M.

    1984-10-01

    A simple theory for establishing the stability or instability of positron-atomic systems against dissociation is presented. The theory consists of assuming that Morse-potential parameters for protonic diatoms are transferrable to the corresponding positronic molecules, and making appropriate reduced-mass modifications in the calculation of binding energies. The surprisingly good reliability of the method is established by appealing to the well-known positronium affinities of atomic hydrogen and fluorine. Positronium (Ps) binding is found for about half of the 42 atoms tested. In addition, instability is indicated for all nine positron-atom systems tested, and stability is indicated for seven of eight negatively charged systems tested; e.g., PsO/sup -/.

  18. An Affordable Concurrent Approach to Positron Polarization Potentials

    NASA Astrophysics Data System (ADS)

    Nichols, Patrick J.; Gibson, Thomas L.

    2000-06-01

    In order to extend our work on low-energy positron-matter collisions to larger target molecules, we are in the process of purchasing and installing a high-performance, parallel computer for less than $15,000. The system will be constructed from commodity PC-class components, such as Intel Celeron Processors with standard memory, hard drives, and fast ethernet cards. The operating system software, compilers, and standard message-passing routines for this system are available for free from the Beowulf Project. Our modified quantum chemistry codes for generating positron-molecule interaction potentials within the Distributed Positron Model are being converted to parallel form and will be made available for download over the internet. We will present details of our work along with some comparative results.

  19. Spectral and spatial characterisation of laser-driven positron beams

    NASA Astrophysics Data System (ADS)

    Sarri, G.; Warwick, J.; Schumaker, W.; Poder, K.; Cole, J.; Doria, D.; Dzelzainis, T.; Krushelnick, K.; Kuschel, S.; Mangles, S. P. D.; Najmudin, Z.; Romagnani, L.; Samarin, G. M.; Symes, D.; Thomas, A. G. R.; Yeung, M.; Zepf, M.

    2017-01-01

    The generation of high-quality relativistic positron beams is a central area of research in experimental physics, due to their potential relevance in a wide range of scientific and engineering areas, ranging from fundamental science to practical applications. There is now growing interest in developing hybrid machines that will combine plasma-based acceleration techniques with more conventional radio-frequency accelerators, in order to minimise the size and cost of these machines. Here we report on recent experiments on laser-driven generation of high-quality positron beams using a relatively low energy and potentially table-top laser system. The results obtained indicate that current technology allows to create, in a compact setup, positron beams suitable for injection in radio-frequency accelerators.

  20. Recent progress in tailoring trap-based positron beams

    SciTech Connect

    Natisin, M. R.; Hurst, N. C.; Danielson, J. R.; Surko, C. M.

    2013-03-19

    Recent progress is described to implement two approaches to specially tailor trap-based positron beams. Experiments and simulations are presented to understand the limits on the energy spread and pulse duration of positron beams extracted from a Penning-Malmberg (PM) trap after the particles have been buffer-gas cooled (or heated) in the range of temperatures 1000 {>=} T {>=} 300 K. These simulations are also used to predict beam performance for cryogenically cooled positrons. Experiments and simulations are also presented to understand the properties of beams formed when plasmas are tailored in a PM trap in a 5 tesla magnetic field, then non-adiabatically extracted from the field using a specially designed high-permeability grid to create a new class of electrostatically guided beams.

  1. Spectral and spatial characterisation of laser-driven positron beams

    DOE PAGES

    Sarri, G.; Warwick, J.; Schumaker, W.; ...

    2016-10-18

    The generation of high-quality relativistic positron beams is a central area of research in experimental physics, due to their potential relevance in a wide range of scientific and engineering areas, ranging from fundamental science to practical applications. There is now growing interest in developing hybrid machines that will combine plasma-based acceleration techniques with more conventional radio-frequency accelerators, in order to minimise the size and cost of these machines. Here we report on recent experiments on laser-driven generation of high-quality positron beams using a relatively low energy and potentially table-top laser system. Lastly, the results obtained indicate that current technology allowsmore » to create, in a compact setup, positron beams suitable for injection in radio-frequency accelerators.« less

  2. Spectral and spatial characterisation of laser-driven positron beams

    SciTech Connect

    Sarri, G.; Warwick, J.; Schumaker, W.; Poder, K.; Cole, J.; Doria, D.; Dzelzainis, T.; Krushelnick, K.; Kuschel, S.; Mangles, S. P. D.; Najmudin, Z.; Romagnani, L.; Samarin, G. M.; Symes, D.; Thomas, A. G. R.; Yeung, M.; Zepf, M.

    2016-10-18

    The generation of high-quality relativistic positron beams is a central area of research in experimental physics, due to their potential relevance in a wide range of scientific and engineering areas, ranging from fundamental science to practical applications. There is now growing interest in developing hybrid machines that will combine plasma-based acceleration techniques with more conventional radio-frequency accelerators, in order to minimise the size and cost of these machines. Here we report on recent experiments on laser-driven generation of high-quality positron beams using a relatively low energy and potentially table-top laser system. Lastly, the results obtained indicate that current technology allows to create, in a compact setup, positron beams suitable for injection in radio-frequency accelerators.

  3. Theoretical calculation of positron affinities of solute clusters in aluminum alloys

    NASA Astrophysics Data System (ADS)

    Mizuno, Masataka; Araki, Hideki; Shirai, Yasuharu

    2016-01-01

    We have performed theoretical calculations of positron states for solute clusters in aluminum alloys to estimate the positron affinity of solute clusters. Positron states of solute clusters in aluminum alloys were calculated under the electronic structures obtained by first- principles molecular orbital calculations using Al158-X13 clusters. We defined the positron affinity of the solute clusters by the difference in the lowest potential sensed by positrons between the solute clusters and Al bulk. With increasing atomic number of 3d metals, the annihilation fraction of the solute clusters rapidly increases at Mn and shows a maximum at Ni. A similar trend is observed for 4d metals. The localization of positron at the solute clusters mainly arises from charge transfer from Al matrix to solute clusters. The positron affinity defined in this work well represents the localization of positron at the solute clusters in aluminum alloys.

  4. 77 FR 71802 - Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-04

    ... ``Investigational New Drug Applications for Positron Emission Tomography (PET) Drugs.'' The guidance is intended to assist manufacturers of PET drugs in submitting investigational new drug applications (INDs). DATES... guidance entitled ``Investigational New Drug Applications for Positron Emission Tomography (PET)...

  5. Monte carlo simulation of positron induced secondary electrons in thin carbon foils

    NASA Astrophysics Data System (ADS)

    Cai, L. H.; Yang, B.; Ling, C. C.; Beling, C. D.; Fung, S.

    2011-01-01

    Emission of secondary electrons induced by the passage of low energy positrons through thin carbon foils was studied by the Monte Carlo method. The positron and electron elastic cross sections were calculated by partial wave analysis. The inelastic positron-valence-electron was described by the energy loss function obtained from dielectric theory. The positron-core-electron interaction was modelled by the Gryzinski's excitation function. Positron transport inside the carbon foil was simulated in detail. Secondary electrons created by positrons and high energy secondary electrons through inelastic interactions were tracked through the foil. The positron transmission coefficient and secondary electron yielded in forward and backward geometry are calculated and dependences on positron energy and carbon foil thickness are discussed.

  6. Conceptual design of an intense positron source based on an LIA

    NASA Astrophysics Data System (ADS)

    Long, Ji-Dong; Yang, Zhen; Dong, Pan; Shi, Jin-Shui

    2012-04-01

    Accelerator based positron sources are widely used due to their high intensity. Most of these accelerators are RF accelerators. An LIA (linear induction accelerator) is a kind of high current pulsed accelerator used for radiography. A conceptual design of an intense pulsed positron source based on an LIA is presented in the paper. One advantage of an LIA is its pulsed power being higher than conventional accelerators, which means a higher amount of primary electrons for positron generations per pulse. Another advantage of an LIA is that it is very suitable to decelerate the positron bunch generated by bremsstrahlung pair process due to its ability to adjustably shape the voltage pulse. By implementing LIA cavities to decelerate the positron bunch before it is moderated, the positron yield could be greatly increased. These features may make the LIA based positron source become a high intensity pulsed positron source.

  7. Positron emission tomography: the conceptual idea using a multidisciplinary approach.

    PubMed

    Paans, Anne M J; van Waarde, Aren; Elsinga, Philip H; Willemsen, Antoon T M; Vaalburg, Willem

    2002-07-01

    Positron emission tomography (PET) is a method for quantitatively measuring biochemical and physiological processes in vivo by using radiopharmaceuticals labeled with positron-emitting radionuclides such as 11C, 13N, 15O, and 18F and by measuring the annihilation radiation using a coincidence technique. This technique is also used for measurement of the pharmacokinetics of labeled drugs and measurement of the effects of drugs on metabolism. Deviations from normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained.

  8. Positron annihilation spectroscopy of biological tissue in 11C irradiation.

    PubMed

    Sakurai, Hiroshi; Itoh, Fumitake; Hirano, Yoshiyuki; Nitta, Munetaka; Suzuki, Kosuke; Kato, Daisuke; Yoshida, Eiji; Nishikido, Fumihiko; Wakizaka, Hidekatsu; Kanai, Tatsuaki; Yamaya, Taiga

    2014-11-21

    Positron annihilation spectroscopy (PAS) spectra of biological tissue in 11C irradiation are reported and spatial resolution coefficient of positron emission tomography (PET) obtained from the PAS spectrum is discussed for 11C irradiation. A PAS spectrum of the biological tissue with water is the same as that of the water pool phantom in 11C irradiation. However, a PAS spectrum of the biological tissue with less water differs from that of the water pool phantom. The PET spatial resolution coefficient depends on the kind of biological tissue. However, the PET spatial resolution coefficient, 0.00243±0.00014, can be used as a common value of maximum limit.

  9. Bismuth germanate as a potential scintillation detector in positron cameras.

    PubMed

    Cho, Z H; Farukhi, M R

    1977-08-01

    Timing and energy resolutions of the bismuth germanate (Bi4Ge3O12) scintillation crystals were studied, with particular respect to a positron-camera application. In comparison with the NaI(Tl) system, the detection efficiency for annihilation radiation is more than triple, and coincidence detection efficiency is more than ten times as good. This paper explores the properties of the new scintillator material and their bearing on the spatial resolution and the efficiency of coincidence detection in positron cameras with stationary ring detectors.

  10. Positron lifetime studies in thermoplastic polyimide test specimens

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Stclair, T. L.; Holt, W. H.; Mock, W., Jr.

    1982-01-01

    Positron lifetime measurements were made in two thermoplastic polyimide materials recently developed at Langley. The long component lifetime values in polyimidesulfone samples are 847 + or - 81 Ps (dry) and 764 + or - 91 Ps (saturated). The corresponding values in LARC thermoplastic imides are 1080 + or - 139 Ps (dry) and 711 + or - 96 Ps (saturated). Clearly, the presence of moisture has greater effect on positron lifetime in LARC thermoplastic imides than in the case of polyimidesulfones. This result is consistent with the photomicrographic observations made on frozen water saturated specimens of these materials.

  11. Positron-annihilation spectroscopy of vacancy defects in aluminum

    SciTech Connect

    Chakraborty, B.; Berko, S.; Fluss, M.J.; Hoffmann, K.; Lippel, P.; Siegel, R.W.

    1982-06-01

    Positron-annihilation characteristics in a monovacancy and a divacancy in aluminium have been calculated self-consistently using a local density functional formalism, into which the many-body enhancement effects have been incorporated. Results for the theoretical two-dimensional angular correlation of annihilation radiation spectra are compared to experimental results obtained from an aluminum single crystal at 20/sup 0/C, where positrons annihilate from a Bloch-state, and at higher temperatures, 500/sup 0/C and 630/sup 0/C, where they annihilate primarily from vacancy-trapped states.

  12. Positronium formation in positron-rubidium inelastic scattering

    NASA Astrophysics Data System (ADS)

    Abdel-Raouf, M. A.

    1988-04-01

    Eight partial cross sections of positron-rubidium ( 37Rb) inelastic scattering (corresponding to 0 ⩽ l⩽ 7, where l is the total angular momentum) are calculated at 25 values of the incident energy ranging from 0.1 to 1000 eV. The calculations are carried out using Clementi-Roetti's wavefunctions, and a combination of the coupled-static and frozen-core approximations. A comparison between the total positronium formation cross sections of the collisions of positrons with four different alkali atoms (lithium, sodium, potassium and rubidium) is presented.

  13. Observation of Polarized Positrons from an Undulator-Based Source

    SciTech Connect

    Alexander, G; Barley, J.; Batygin, Y.; Berridge, S.; Bharadwaj, V.; Bower, G.; Bugg, W.; Decker, F.-J.; Dollan, R.; Efremenko, Y.; Gharibyan, V.; Hast, C.; Iverson, R.; Kolanoski, H.; Kovermann, J.; Laihem, K.; Lohse, T.; McDonald, K.T.; Mikhailichenko, A.A.; Moortgat-Pick, G.A.; Pahl, P.; /Tel Aviv U. /Cornell U., Phys. Dept. /SLAC /Tennessee U. /Humboldt U., Berlin /DESY /Yerevan Phys. Inst. /Aachen, Tech. Hochsch. /DESY, Zeuthen /Princeton U. /Durham U. /Daresbury

    2008-03-06

    An experiment (E166) at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which a multi-GeV electron beam passed through a helical undulator to generate multi-MeV, circularly polarized photons which were then converted in a thin target to produce positrons (and electrons) with longitudinal polarization above 80% at 6 MeV. The results are in agreement with Geant4 simulations that include the dominant polarization-dependent interactions of electrons, positrons and photons in matter.

  14. Positron plasma control techniques for the production of cold antihydrogen

    SciTech Connect

    Funakoshi, R.; Hayano, R. S.; Amoretti, M.; Macri, M.; Testera, G.; Variola, A.; Bonomi, G.; Bowe, P. D.; Hangst, J. S.; Madsen, N.; Canali, C.; Carraro, C.; Lagomarsino, V.; Manuzio, G.; Cesar, C. L.; Charlton, M.; Joergensen, L. V.; Mitchard, D.; Werf, D. P. van der; Doser, M.

    2007-07-15

    An observation of a clear dependence of antihydrogen production on positron plasma shapes is reported. For this purpose a plasma control method has been developed combining the plasma rotating-wall technique with a mode diagnostic system. With the help of real-time and nondestructive observations, the rotating-wall parameters have been optimized. The positron plasma can be manipulated into a wide range of shapes (aspect ratio 6.5{<=}{alpha} < or approx. 80) and densities (1.5x10{sup 8}{<=}n < or approx. 7x10{sup 9} cm{sup -3}) within a short duration (25 s) compatible with the ATHENA antihydrogen production cycle.

  15. What can we learn from a sharply falling positron fraction?

    NASA Astrophysics Data System (ADS)

    Delahaye, Timur; Kotera, Kumiko; Silk, Joseph

    2015-12-01

    Recent results from the AMS-02 data have confirmed that the cosmic ray positron fraction increases with energy between 10 and 200 GeV. This quantity should not exceed 50%, and it is hence expected that it will either converge towards 50% or fall. We study the possibility that future data may show the positron fraction dropping down abruptly to the level expected with only secondary production, and forecast the implications of such a feature in term of possible injection mechanisms that include both Dark Matter and pulsars.

  16. Positronics of radiation-induced effects in chalcogenide glassy semiconductors

    SciTech Connect

    Shpotyuk, O.; Kozyukhin, S. A.; Shpotyuk, M.; Ingram, A.; Szatanik, R.

    2015-03-15

    Using As{sub 2}S{sub 3} and AsS{sub 2} glasses as an example, the principal possibility of using positron annihilation spectroscopy methods for studying the evolution of the free volume of hollow nanoobjects in chalcogenide glassy semiconductors exposed to radiation is shown. The results obtained by measurements of the positron annihilation lifetime and Doppler broadening of the annihilation line in reverse chronological order are in full agreement with the optical spectroscopy data in the region of the fundamental absorption edge, being adequately described within coordination defect-formation and physical-aging models.

  17. Positron beam studies of saponite film prepared by precipitation method

    NASA Astrophysics Data System (ADS)

    Numata, K.; Sato, K.; Fujimoto, K.; Ito, K.

    2017-01-01

    Micrometer-sized saponite particles were isolated by means of gravitational sedimentation method applying Stokes’ law. The sample prepared with this method was film-like state with a thickness of ~ 30 μm and was semitransparent, indicating that the particles are homogeneously stacked all together. Positron lifetime spectroscopy using a slow positron beam yielded two components for ortho-positronium with lifetimes of 1.5 ns and 8.4 ns with the respective relative intensities of 13 % and 10 %. The results suggest that the self-assembly of the larger particles toward structural densification is suppressed for the present film in comparison with the smaller nanoparticles.

  18. Positron studies in catalysis research. Final report, September 1993-- May 1995

    SciTech Connect

    1996-05-01

    During the past 20 months, we have completed our positron microscope and performed several studies in our nonmicroscopic depth-profiling positron spectrometer which should ultimately be applicable to catalysis. These studies involve using depth-profiled positron spectrometers to observe the growth dynamics of metal silicides on silicon substrates and to observe defects in glassy polymer surfaces and thin films, and the use of bulk positron lifetime measurements to observe pore-size variations in zeolites.

  19. A low energy positron accumulator for the plasma confinement in a compact magnetic mirror trap

    SciTech Connect

    Higaki, Hiroyuki Kaga, Chikato; Nagayasu, Katsushi; Okamoto, Hiromi; Nagata, Yugo; Kanai, Yasuyuki; Yamazaki, Yasunori

    2015-06-29

    A low energy positron accumulator was constructed at RIKEN for the purpose of confining an electron-positron plasma. The use of 5 mCi {sup 22}Na RI source with a standard solid Ne moderator and N{sub 2} buffer gas cooling resulted in a low energy positron yield of ∼ 3 × 10{sup 5} e+/s. So far, 2 × 10{sup 6} positrons have been accumulated in 120s.

  20. Observation of exclusive electron-positron production in hadron-hadron collisions.

    PubMed

    Abulencia, A; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arguin, J-F; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Budroni, S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carillo, S; Carlsmith, D; Caron, B; Carosi, R; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciljak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Almenar, C Cuenca; Cuevas, J; Culbertson, R; Cully, J C; Cyr, D; Daronco, S; D'Auria, S; Davies, T; D'Onofrio, M; Dagenhart, D; de Barbaro, P; Cecco, S De; Deisher, A; Lentdecker, G De; Dell'orso, M; Paoli, F Delli; Demortier, L; Deng, J; Deninno, M; Pedis, D De; Derwent, P F; Giovanni, G P Di; Dionisi, C; Ruzza, B Di; Dittmann, J R; Dituro, P; Dörr, C; Donati, S; Donega, M; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garcia, J E; Garberson, F; Garfinkel, A F; Gay, C; Gerberich, H; Gerdes, D; Giagu, S; Giannetti, P; Gibson, A; Gibson, K; Gimmell, J L; Ginsburg, C; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Griffiths, M; Grinstein, S; Grosso-Pilcher, C; Grundler, U; da Costa, J Guimaraes; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jensen, H; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kovalev, A; Kraan, A C; Kraus, J; Kravchenko, I; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Manca, G; Margaroli, F; Marginean, R; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Maruyama, T; Mastrandrea, P; Masubuchi, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyamoto, A; Moed, S; Moggi, N; Mohr, B; Moore, R; Morello, M; Fernandez, P Movilla; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Nachtman, J; Nagano, A; Naganoma, J; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nigmanov, T; Nodulman, L; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pinfold, J; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ranjan, N; Rappoccio, S; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Sabik, S; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Saltzberg, D; Sánchez, C; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyrla, A; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Sjolin, J; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; Denis, R St; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuchiya, R; Tsuno, S; Turini, N; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Veramendi, G; Veszpremi, V; Vidal, R; Vila, I; Vilar, R; Vine, T; Vollrath, I; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, J; Wagner, W; Wallny, R; Wang, S M; Warburton, A; Waschke, S; Waters, D; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zhou, J; Zucchelli, S

    2007-03-16

    We present the first observation of exclusive e(+)e(-) production in hadron-hadron collisions, using pp[over] collision data at (square root) s = 1.96 TeV taken by the run II Collider Detector at Fermilab, and corresponding to an integrated luminosity of 532 pb(-1). We require the absence of any particle signatures in the detector except for an electron and a positron candidate, each with transverse energy E(T) > 5 GeV and pseudorapidity |eta| < 2. With these criteria, 16 events are observed compared to a background expectation of 1.9+/-0.3 events. These events are consistent in cross section and properties with the QED process pp[over] --> p + e(+)e(-) + p[over] through two-photon exchange. The measured cross section is 1.6(-0.3)(+0.5)(stat) +/- 0.3(syst) pb. This agrees with the theoretical prediction of 1.71+/-0.01 pb.

  1. Positron emission tomography demonstrated localized luxury perfusion in subacute sclerosing panencephalitis.

    PubMed

    Yoshikawa, H; Fueki, N; Yoneyama, H; Ogawa, M; Sakuragawa, N

    1990-10-01

    Positron emission tomography (PET) was performed on two patients in different stages of subacute sclerosing panencephalitis (SSPE) and compared with the concurrent computed tomography (CT) findings and clinical status. Case 1, which was in stage II, showed luxury perfusion in the anterior half of the cerebrum and decreases of cerebral blood flow and oxygen metabolism in the right frontal watershed zone, where CT showed low density. Case 2, which was in stage III, showed marked decreases of cerebral blood flow and cerebral metabolic rate of oxygen in all regions except the occipital region. The present PET study demonstrated that SSPE showed inflammatory-destructive progression and rostral-caudal progression. Further, it was suspected that low density on CT scan, especially in the watershed zone, resulted partly from disturbances in cerebral circulation.

  2. The Effects of Surface Reconstruction and Electron-Positron Correlation on the Annihilation Characteristics of Positrons Trapped at Semiconductor Surfaces

    SciTech Connect

    Fazleev, N. G.; Jung, E.; Weiss, A. H.

    2009-03-10

    Experimental positron annihilation induced Auger electron spectroscopy (PAES) data from Ge(100) and Ge(111) surfaces display several strong Auger peaks corresponding to M{sub 4,5}N{sub 1}N{sub 2,3}, M{sub 2,3}M{sub 4,5}M{sub 4,5}, M{sub 2,3}M{sub 4,5}V, and M{sub 1}M{sub 4,5}M{sub 4,5} Auger transitions. The integrated peak intensities of Auger transitions have been used to obtain experimental annihilation probabilities for the Ge 3d and 3p core electrons. The experimental data were analyzed by performing theoretical studies of the effects of surface reconstructions and electron-positron correlations on image potential induced surface states and annihilation characteristics of positrons trapped at the reconstructed Ge(100) and Ge(111) surfaces. Calculations of positron surface states and annihilation characteristics have been performed for Ge(100) surface with (2x1), (2x2), and (4x2) reconstructions, and for Ge(111) surface with c(2x8) reconstruction. Estimates of the positron binding energy and annihilation characteristics reveal their sensitivity to the specific atomic structure of the topmost layers of the semiconductor and to the approximations used to describe electron-positron correlations. The results of these theoretical studies are compared with the ones obtained for the reconstructed Si(100)-(2x1) and Si(111)-(7x7) surfaces.

  3. Measuring positron-atom binding energies through laser-assisted photorecombination

    NASA Astrophysics Data System (ADS)

    Surko, C. M.; Danielson, J. R.; Gribakin, G. F.; Continetti, R. E.

    2012-06-01

    Described here is a proposed experiment to use laser-assisted photorecombination of positrons from a trap-based beam and metal atoms in the gas phase to measure positron-atom binding energies. Signal rates are estimated, based in part upon experience studying resonant annihilation spectra using a trap-based positron beam.

  4. Acceleration of positrons by a relativistic electron beam in the presence of quantum effects

    SciTech Connect

    Niknam, A. R.; Aki, H.; Khorashadizadeh, S. M.

    2013-09-15

    Using the quantum magnetohydrodynamic model and obtaining the dispersion relation of the Cherenkov and cyclotron waves, the acceleration of positrons by a relativistic electron beam is investigated. The Cherenkov and cyclotron acceleration mechanisms of positrons are compared together. It is shown that growth rate and, therefore, the acceleration of positrons can be increased in the presence of quantum effects.

  5. Defects in nitride-based semiconductors probed by positron annihilation

    NASA Astrophysics Data System (ADS)

    Uedono, A.; Sumiya, M.; Ishibashi, S.; Oshima, N.; Suzuki, R.

    2014-04-01

    Point defects in InxGa1-xN grown by metal organic chemical vapor deposition were studied by a monoenergetic positron beam. Measurements of Doppler broadening spectra of the annihilation radiation as a function of incident positron energy for InxGa1-xN (x = 0.08 and 0.14) showed that vacancy-type defects were introduced with increasing InN composition. From comparisons between coincidence Doppler broadening spectra and the results calculated using the projector augmented-wave method, the major defect species was identified as the complexes between a cation vacancy and nitride vacancies. The concentration of the defects was found to be suppressed by Mg doping. An effect of Mg-doping on the positron diffusion properties in GaN and InN was also discussed. The momentum distribution of electrons at the InxGa1-xN/GaN interface was close to that in defect-free GaN or InxGa1-xN, which was attributed to the localization of positrons at the interface due to the electric field caused by polarizations.

  6. Advances in defect characterizations of semiconductors using positrons

    SciTech Connect

    Lynn, K.G.; Asoka-Kumar, P.

    1996-12-31

    Positron Annihilation Spectroscopy (PAS) is a sensitive probe for studying the electronic structure of defects in solids. The authors summarize recent developments in defect characterization of semiconductors using depth-resolved PAS. The progress achieved in extending the capabilities of the PAS method is also described.

  7. On positron annihilation in concentrated random alloys and superconducting cuprates

    SciTech Connect

    Szotek, Z.; Temmerman, W.M.; Gyorffy, B.L.; Stocks, G.M.

    1988-01-01

    We discuss an application of a generalisation of the Lock-Crisp-West theorem to concentrated random alloys. Using a theory developed for binary random alloys we explore a possibility of positron localisation in the new high temperature superconductors. 7 refs., 1 fig.

  8. An outline of positron measurements of superconducting oxides

    SciTech Connect

    Howell, R.H.; Fluss, M.J.

    1991-03-01

    Positron measurements on superconducting oxides have gone through an evolution from divergent results of low statistical precision on samples of suspect quality to convergent results of higher statistical precision on high quality samples. We outline the elements affecting the progress of these experiments and questions that can be addressed at our present state of the art. 11 refs.

  9. Industrial positron-based imaging: Principles and applications

    NASA Astrophysics Data System (ADS)

    Parker, D. J.; Hawkesworth, M. R.; Broadbent, C. J.; Fowles, P.; Fryer, T. D.; McNeil, P. A.

    1994-09-01

    Positron Emission Tomography (PET) has great potential as a non-invasive flow imaging technique in engineering, since 511 keV gamma-rays can penetrate a considerable thickness of (e.g.) steel. The RAL/Birmingham multiwire positron camera was constructed in 1984, with the initial goal of observing the lubricant distribution in operating aero-engines, automotive engines and gearboxes, and has since been used in a variety of industrial fields. The major limitation of the camera for conventional tomographic PET studies is its restricted logging rate, which limits the frequency with which images can be acquired. Tracking a single small positron-emitting tracer particle provides a more powerful means of observing high speed motion using such a camera. Following a brief review of the use of conventional PET in engineering, and the capabilities of the Birmingham camera, this paper describes recent developments in the Positron Emission Particle Tracking (PEPT) technique, and compares the results obtainable by PET and PEPT using, as an example, a study of axial diffusion of particles in a rolling cylinder.

  10. Investigational study of iodine-124 with a positron camera

    SciTech Connect

    Lambrecht, R.M.; Woodhouse, N.; Phillips, R.; Wolczak, D.; Qureshi, A.; Reyes, E.D.; Graser, C.; Al-Yanbawi, S.; Al-Rabiah, A.; Meyer, W.

    1988-01-01

    A case is presented where I-124 produced by a clinical cyclotron was used with a positron emission tomography camera for clinical usage. This represents the first report of the utilization of this modality with this radionuclide. We feel the increased spatial resolution of PET should be of value in looking at thyroid disease.

  11. Simulation of tail distributions in electron-positron circular colliders

    SciTech Connect

    Irwin, J.

    1992-02-01

    In addition to the Gaussian shaped core region, particle bunches in electron-positron circular colliders have a rarefied halo region of importance in determining beam lifetimes and backgrounds in particle detectors. A method is described which allows simulation of halo particle distributions.

  12. Theoretical Formalism To Estimate the Positron Scattering Cross Section.

    PubMed

    Singh, Suvam; Dutta, Sangita; Naghma, Rahla; Antony, Bobby

    2016-07-21

    A theoretical formalism is introduced in this article to calculate the total cross sections for positron scattering. This method incorporates positron-target interaction in the spherical complex optical potential formalism. The study of positron collision has been quite subtle until now. However, recently, it has emerged as an interesting area due to its role in atomic and molecular structure physics, astrophysics, and medicine. With the present method, the total cross sections for simple atoms C, N, and O and their diatomic molecules C2, N2, and O2 are obtained and compared with existing data. The total cross section obtained in the present work gives a more consistent shape and magnitude than existing theories. The characteristic dip below 10 eV is identified due to the positronium formation. The deviation of the present cross section with measurements at energies below 10 eV is attributed to the neglect of forward angle-discrimination effects in experiments, the inefficiency of additivity rule for molecules, empirical treatment of positronium formation, and the neglect of annihilation reactions. In spite of these deficiencies, the present results show consistent behavior and reasonable agreement with previous data, wherever available. Besides, this is the first computational model to report positron scattering cross sections over the energy range from 1 to 5000 eV.

  13. Positron lifetime studies in vinyl polymers of medical importance

    NASA Astrophysics Data System (ADS)

    Ferreira Marques, M. F.; Gordo, P. M.; Gil, C. Lopes; Kajcsos, Zs.; Gil, M. H.; Mariz, M. J.; de Lima, A. P.

    2003-10-01

    Vinyl polymers used as artificial lens implants in ophthalmology were investigated by positron lifetime spectroscopy. The structure of these polymers with free volumes offers the possibility of charging them with anti-inflammatory drugs for sustained release. A correlation between the amount of normalised free volume and the ratio of the methyl methacrylate to ethyl-hexyl-acrylate, used as polymerisation monomers, was found.

  14. Initial results on positron confinement in a magnetospheric configuration

    NASA Astrophysics Data System (ADS)

    Saitoh, Haruhiko; Yoshida, Zensho; Yano, Yoshihisa; Morikawa, Junji

    2011-10-01

    Creation of positron-electron plasma in a laboratory is an interesting and challenging subject, which may open many scientific applications. Although single-component plasma is stably confined in linear traps, for example Penning-Malmberg trap, it is not straightforward to simultaneously confine electrons and positrons as plasma. Toroidal geometries have advantages for solving this problem. For this purpose, studies on toroidal non-neutral plasma have been conducted in the levitated magnetospheric configuration, RT-1. Stable confinement and self-organization of toroidal non-neutral plasma was realized in RT-1; rigid-rotating pure electron plasma is confined for more than 300s [Z. Yoshida et al., PRL 104, 235004 (2010)]. As the initial step toward the formation of magnetospheric antimatter plasmas, we installed a 1MBq Na-22 radiation source in RT-1. Annihilation gamma-rays were observed by a NaI(TI) scintillator detector, for the estimation of basic injection and confinement properties of positrons in the magnetospheric configuration. Numerical analysis of positron orbits in RT-1 and the initial experimental results will be presented. Work funded by MEXT of Japan (23224014, 23654201).

  15. A novel design for a variable energy positron lifetime spectrometer

    NASA Astrophysics Data System (ADS)

    Chen, D.; Zhang, J. D.; Cheng, C. C.; Beling, C. D.; Fung, S.

    2008-10-01

    We present computer simulations of a new design of a variable energy positron lifetime beam that uses for a start signal the secondary electron emission from a 25-nm thick carbon foil (C-foil) located in front of the sample. A needle of ˜30 μm diameter is positioned on-axis right behind the foil, creating a radial electric field that deflects the secondary electrons radially outward so as to miss the sample and to hit the micro-channel plate (MCP) detector placed down beam. The MCP signal provides the start signal for the positron lifetime spectrometer. A grid can be further introduced between the sample holder and the MCP to yield a cleaner signal by preventing the positrons with large transmitted scattering angle from hitting the MCP. The cylindrical symmetry of this design reduces the experimental complexity and offers good timing resolution. We show that the design is robust against the transmitted energy and angle of the secondary electrons and positrons.

  16. Design of a pulsed positron system at Trombay

    NASA Astrophysics Data System (ADS)

    Mukherjee, S.; Sharma, S. K.; Maheshwari, Priya; Gupta, S. K.; Pujari, P. K.

    2015-06-01

    We present here the design of a pulsed beam setup to deliver narrow time width positron pulses. The major constituents of the setup include- 22Na radioactive source and moderator assembly, ExB deflector for filtering out high energy positron and gamma rays, chopper-prebuncher-buncher assembly for time bunching of the slow positrons. In the ExB section, crossed electric and magnetic fields guide the slow positrons through an off-centered hole in a tungsten block. The initial beam will then be time bunched by using a reflection type chopper and a double gap prebuncher. The main buncheris designed as a quarter wave resonator with base frequency of 150 MHz.To prevent the sagging of the cantilevered inner tube of the resonator, we will support the inner conductor using an alumina post. There will be provision of tuning the frequency by using a tuner made of conducting material. The incident beam energy will be varied by biasing the sample.

  17. Positron Emission Tomography: Human Brain Function and Biochemistry.

    ERIC Educational Resources Information Center

    Phelps, Michael E.; Mazziotta, John C.

    1985-01-01

    Describes the method, present status, and application of positron emission tomography (PET), an analytical imaging technique for "in vivo" measurements of the anatomical distribution and rates of specific biochemical reactions. Measurements and image dynamic biochemistry link basic and clinical neurosciences with clinical findings…

  18. Positron Annihilation Spectroscopy Study of Barnett Shale Core

    NASA Astrophysics Data System (ADS)

    Ameena, Fnu; Alsleben, Helge; Quarles, Carroll A.

    Measurements are reported of positron annihilation lifetime and Doppler broadening parameters on 14 samples of Barnett shale core selected from 196 samples ranging from depths of 6107 to 6402 feet. The Barnett shale core was taken from EOG well Two-O-Five 2H located in Johnson county TX. The selected samples are dark clay-rich mudstone consisting of fine-grained clay minerals. The samples are varied in shape, typically a few inches long and about 1/2 inch in width and thickness, and are representative of the predominant facies in the core. X-ray fluorescence (XRF), X-ray diffraction (XRD), petrographic analysis and geochemical analysis of total organic carbon (TOC) were already available for each of the selected samples. The lifetime data are analyzed in terms of three lifetime components with the shortest lifetime fixed at 125 ps. The second lifetime is attributed to positron annihilation in the bulk and positron trapping; and the third lifetime is due to positronium. Correlations of the lifetimes, intensities, the average lifetime and S and W parameters with TOC, XRF and XRD parameters are discussed. The observed correlations suggest that positron spectroscopy may be a useful tool in characterizing shale.

  19. Search for bound-state electron+positron pair decay

    NASA Astrophysics Data System (ADS)

    Bosch, F.; Hagmann, S.; Hillenbrand, P.-M.; Lane, G. J.; Litvinov, Yu. A.; Reed, M. W.; Sanjari, M. S.; Stöhlker, Th.; Torilov, S. Yu.; Tu, X. L.; Walke, P. M.

    2016-09-01

    The heavy ion storage rings coupled to in-flight radioactive-ion beam facilities, namely the ability to produce and store for extended periods of time radioactive nuclides in high atomic charge states, for the searchof yet unobserved decay mode - bound-state electron-positron pair decay.

  20. Positron annihilation spectroscopy study of materials for reactor vessels

    NASA Astrophysics Data System (ADS)

    Grafutin, V. I.; Prokop'ev, E. P.; Krsjak, V.; Burcl, R.; Hähner, P.; Zeman, A.; Ilyukhina, O. V.; Erak, D.; Mogilevskyi, M. A.; Myasischeva, G. G.; Funtikov, Yu. V.

    2011-02-01

    Steels used in the nuclear industry have been experimentally studied by positron annihilation spectroscopy. Analysis of the experimental results and their comparison with the existing data make it possible to reveal vacancy defects, in particular, those caused by neutron radiation, and to determine their size.

  1. Studies of Positron Generation from Ultraintense Laser-Matter Interactions

    NASA Astrophysics Data System (ADS)

    Williams, Gerald Jackson

    Laser-produced pair jets possess unique characteristics that offer great potential for their use in laboratory-astrophysics experiments to study energetic phenomenon such as relativistic shock accelerations. High-flux, high-energy positron sources may also be used to study relativistic pair plasmas and useful as novel diagnostic tools for high energy density conditions. Copious amounts of positrons are produced with MeV energies from directly irradiating targets with ultraintense lasers where relativistic electrons, accelerated by the laser field, drive positron-electron pair production. Alternatively, laser wakefield accelerated electrons can produce pairs by the same mechanisms inside a secondary converter target. This dissertation describes a series of novel experiments that investigate the characteristics and scaling of pair production from ultraintense lasers, which are designed to establish a robust platform for laboratory-based relativistic pair plasmas. Results include a simple power-law scaling to estimate the effective positron yield for elemental targets for any Maxwellian electron source, typical of direct laser-target interactions. To facilitate these measurements, a solenoid electromagnetic coil was constructed to focus emitted particles, increasing the effective collection angle of the detector and enabling the investigation of pair production from thin targets and low-Z materials. Laser wakefield electron sources were also explored as a compact, high repetition rate platform for the production of high energy pairs with potential applications to the creation of charge-neutral relativistic pair plasmas. Plasma accelerators can produce low-divergence electron beams with energies approaching a GeV at Hz frequencies. It was found that, even for high-energy positrons, energy loss and scattering mechanisms in the target create a fundamental limit to the divergence and energy spectrum of the emitted positrons. The potential future application of laser

  2. Monte Carlo modeling and optimization of buffer gas positron traps

    NASA Astrophysics Data System (ADS)

    Marjanović, Srđan; Petrović, Zoran Lj

    2017-02-01

    Buffer gas positron traps have been used for over two decades as the prime source of slow positrons enabling a wide range of experiments. While their performance has been well understood through empirical studies, no theoretical attempt has been made to quantitatively describe their operation. In this paper we apply standard models as developed for physics of low temperature collision dominated plasmas, or physics of swarms to model basic performance and principles of operation of gas filled positron traps. The Monte Carlo model is equipped with the best available set of cross sections that were mostly derived experimentally by using the same type of traps that are being studied. Our model represents in realistic geometry and fields the development of the positron ensemble from the initial beam provided by the solid neon moderator through voltage drops between the stages of the trap and through different pressures of the buffer gas. The first two stages employ excitation of N2 with acceleration of the order of 10 eV so that the trap operates under conditions when excitation of the nitrogen reduces the energy of the initial beam to trap the positrons without giving them a chance to become annihilated following positronium formation. The energy distribution function develops from the assumed distribution leaving the moderator, it is accelerated by the voltage drops and forms beams at several distinct energies. In final stages the low energy loss collisions (vibrational excitation of CF4 and rotational excitation of N2) control the approach of the distribution function to a Maxwellian at room temperature but multiple non-Maxwellian groups persist throughout most of the thermalization. Optimization of the efficiency of the trap may be achieved by changing the pressure and voltage drops and also by selecting to operate in a two stage mode. The model allows quantitative comparisons and test of optimization as well as development of other properties.

  3. Optimisation of the thickness of the moderator for positron annihilation process study in Ar gas

    NASA Astrophysics Data System (ADS)

    Oka, Toshitaka; Sano, Yosuke; Kino, Yasushi; Sekine, Tsutomu

    2014-06-01

    To investigate the deceleration and annihilation processes of positron in noble gas, we attempted to optimise the thickness of the positron moderator. The results of the decreasing trend of free positron intensity and ortho-positronium intensity with the thickness, and the annihilation rate suggest that the energy of almost all the positrons passed through the metal foils was much above the positronium formation threshold of 9 eV. Total thickness of 0.1 g cm-2 of the moderator and the Ar gas was required to stop almost all the positron in Ar gas.

  4. Threshold for Trapping Positrons in the Wake Driven by a Ultra-relativistic Electron Bunch

    SciTech Connect

    Wang, X.; Muggli, P.; Katsouleas, T.; Ischebeck, R.; Hogan, M. J.; Joshi, C.; Mori, W. B.

    2009-01-22

    We have recently proposed a new concept for generating, injecting and accelerating positrons in a plasma using a double-pulse electron bunch. Monte Carlo simulations show that the number of the positrons produced in a foil target has an exponentially decay energy spectrum. The energy threshold for the trapping of these positrons in a ultra-relativistic electron wake is investigated numerically. For a typical 28.5 GeV electron drive bunch, the trapping threshold for the positrons is a few MeV, and therefore a majority of positrons generated in the foil target are focused and accelerated by the plasma wake.

  5. Production of Highly Polarized Positrons Using Polarized Electrons at MeV Energies

    SciTech Connect

    Abbott, D.; Adderley, P.; Adeyemi, A.; Aguilera, P.; Ali, M.; Areti, H.; Baylac, M.; Benesch, J.; Bosson, G.; Cade, B.; Camsonne, A.; Cardman, L. S.; Clark, J.; Cole, P.; Covert, S.; Cuevas, C.; Dadoun, O.; Dale, D.; Dong, H.; Dumas, J.; Fanchini, E.; Forest, T.; Forman, E.; Freyberger, A.; Froidefond, E.; Golge, S.; Grames, J.; Guèye, P.; Hansknecht, J.; Harrell, P.; Hoskins, J.; Hyde, C.; Josey, B.; Kazimi, R.; Kim, Y.; Machie, D.; Mahoney, K.; Mammei, R.; Marton, M.; McCarter, J.; McCaughan, M.; McHugh, M.; McNulty, D.; Mesick, K. E.; Michaelides, T.; Michaels, R.; Moffit, B.; Moser, D.; Muñoz Camacho, C.; Muraz, J. -F.; Opper, A.; Poelker, M.; Réal, J. -S.; Richardson, L.; Setiniyaz, S.; Stutzman, M.; Suleiman, R.; Tennant, C.; Tsai, C.; Turner, D.; Ungaro, M.; Variola, A.; Voutier, E.; Wang, Y.; Zhang, Y.

    2016-05-27

    The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-Z target. Positron polarization up to 82% have been measured for an initial electron beam momentum of 8.19~MeV/c, limited only by the electron beam polarization. We report that this technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community.

  6. The “accumulation effect” of positrons in the stack of foils, detected by measurements of the positron implantation profile

    SciTech Connect

    Dryzek, Jerzy; Siemek, Krzysztof

    2013-12-14

    The profiles of positrons implanted from the radioactive source {sup 22}Na into a stack of foils and plates are the subject of our experimental and theoretical studies. The measurements were performed using the depth scanning of positron implantation profile method, and the theoretical calculations using the phenomenological multi-scattering model (MSM). Several stacks consisting of silver, gold and aluminum foils, and titanium and germanium plates were investigated. We notice that the MSM describes well the experimental profiles; however when the stack consisting of silver and gold foils, the backscattering and linear absorption coefficients differ significantly from those reported in the literature. We suggest the energy dependency of the backscattering coefficient for silver and gold. In the stacks which comprise titanium and germanium plates, there were observed the features, which indicate the presence of the “accumulation effect” in the experimental implantation profile. This effect was previously detected in implantation profiles in Monte Carlo simulations using the GEANT4 tool kit, and it consists in higher localization of positrons close the interface. We suppose that this effect can be essential for positron annihilation in any heterogeneous materials.

  7. In vitro positron emission tomography (PET): use of positron emission tracers in functional imaging in living brain slices.

    PubMed

    Matsumura, K; Bergström, M; Onoe, H; Takechi, H; Westerberg, G; Antoni, G; Bjurling, P; Jacobson, G B; Långström, B; Watanabe, Y

    1995-05-01

    Positron-emitting radionuclides have short half-lives and high radiation energies compared with radioisotopes generally used in biomedical research. We examined the possibility of applying positron emitter-labeled compounds to functional imaging in brain slices kept viable in an oxygenated buffer solution. Brain slices (300 microns thick) containing the striatum were incubated with positron emitter-labeled tracers for 30-45 min. The slices were then rinsed and placed on the bottom of a Plexiglas chamber filled with oxygenated Krebs-Ringer solution. The bottom of the chamber consisted of a thin polypropylene film to allow good penetration of beta+ particles from the brain slices. The chamber was placed on a storage phosphor screen, which has a higher sensitivity and a wider dynamic range than X-ray films. After an exposure period of 15-60 min, the screen was scanned by the analyzer and radioactivity images of brain slices were obtained within 20 min. We succeeded in obtaining quantitative images of (1) [18F]fluorodeoxyglucose uptake, (2) dopamine D2 receptor binding, (3) dopa-decarboxylase activity, and (4) release of [11C]dopamine preloaded as L-[11C]DOPA in the brain slice preparation. These results demonstrate that positron emitter-labeled tracers in combination with storage phosphor screens are useful for functional imaging of living brain slices as a novel neuroscience technique.

  8. Positron beam lifetime spectroscopy of atomic scale defect distributions in bulk and microscopic volumes

    SciTech Connect

    Howell, R.H.; Cowan, T.E.; Hartley, J.; Sterne, P.; Brown, B.

    1996-05-01

    We are developing a defect analysis capability based on two positron beam lifetime spectrometers: the first is based on a 3 MeV electrostatic accelerator and the second on our high current linac beam. The high energy beam lifetime spectrometer is operational and positron lifetime analysis is performed with a 3 MeV positron beam on thick samples. It is being used for bulk sample analysis and analysis of samples encapsulated in controlled environments for {ital in}{ital situ} measurements. A second, low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopies is under development at the LLNL high current positron source. This beam will enable defect specific, 3-D maps of defect concentration with sub-micron location resolution and when coupled with first principles calculations of defect specific positron lifetimes it will enable new levels of defect concentration mapping and defect identification.

  9. Rectifying barrier at GaN/SiC hetero-junction studied with positron annihilation spectroscopy

    NASA Astrophysics Data System (ADS)

    Hu, Yi-Fan; Beling, D. C.

    2005-11-01

    Positron annihilation spectroscopy on GaN films grown on SiC substrate with MBE are presented. It is shown that the GaN/SiC interface is rectifying towards positrons, such that positrons can only travel from SiC to GaN and not vice versa. Potential steps seen by the positron at the GaN/SiC interface are calculated from experimental values of electron and positron work function. This ``rectifying'' effect has been successfully mimicked by inserting a thin region of very high electric field in the Variable Energy Positron Fit (VEPF) analysis. The built-in electric field is attributed to different positron affinities, dislocation and/or interface defects at the GaN/SiC interface.

  10. Positron States at Li- and O-adsorbed Fe(001) Ferromagnetic Surfaces Studied by Two-Component Density Functional Theory

    NASA Astrophysics Data System (ADS)

    Hagiwara, Satoshi; Watanabe, Kazuyuki

    2016-11-01

    The positron states for Li- and O-adsorbed Fe(001) ferromagnetic surfaces are studied by using two-component density functional theory. Positron surface lifetimes and positron binding energies are found to be sensitive to changes in the surface structure and the dipole barrier induced by adatoms, which can be understood by the positron density distribution and surface potential. Spin-dependent positron lifetime fractions are in excellent agreement with spin-polarization fractions at the topmost surface, because the localized positrons at the surface are sensitive to the surface magnetic state. Therefore, the present results show that spin-polarized positron annihilation spectroscopy can extract the outermost surface magnetic state.

  11. Centroid shift of. gamma. rays from positron annihilation in the depletion region of metal-oxide-semiconductor structures

    SciTech Connect

    Leung, T.C.; Kong, Y.; Lynn, K.G.; Nielsen, B. ); Weinberg, Z.A.; Rubloff, G.W. )

    1991-01-07

    Using metal-oxide-semiconductor (MOS) structures, the shift of centroid (peak) of {gamma}-ray energy distributions emitted from positron annihilation has been measured as a function of incident positron energy. The Doppler centroid shift was found to be consistent with the positron motion in the MOS depletion region. The results are described by a one-dimensional positron diffusion model, and provide information on effective'' positron diffusion length under applied field.

  12. The predictive role of interim positron emission tomography for Hodgkin lymphoma treatment outcome is confirmed using the interpretation criteria of the Deauville five-point scale.

    PubMed

    Gallamini, Andrea; Barrington, Sally F; Biggi, Alberto; Chauvie, Stephane; Kostakoglu, Lale; Gregianin, Michele; Meignan, Michel; Mikhaeel, George N; Loft, Annika; Zaucha, Jan M; Seymour, John F; Hofman, Michael S; Rigacci, Luigi; Pulsoni, Alessandro; Coleman, Morton; Dann, Eldad J; Trentin, Livio; Casasnovas, Olivier; Rusconi, Chiara; Brice, Pauline; Bolis, Silvia; Viviani, Simonetta; Salvi, Flavia; Luminari, Stefano; Hutchings, Martin

    2014-06-01

    A retrospective, international, multicenter study was undertaken to assess: (i) the prognostic role of 'interim' positron emission tomography performed during treatment with doxorubicin, bleomycin, vinblastine and dacarbazine in patients with Hodgkin lymphoma; and (ii) the reproducibility of the Deauville five-point scale for the interpretation of interim positron emission tomography scan. Two hundred and sixty patients with newly diagnosed Hodgkin lymphoma were enrolled. Fifty-three patients with early unfavorable and 207 with advanced-stage disease were treated with doxorubicin, bleomycin, vinblastine and dacarbazine ± involved-field or consolidation radiotherapy. Positron emission tomography scan was performed at baseline and after two cycles of chemotherapy. Treatment was not changed according to the results of the interim scan. An international panel of six expert reviewers independently reported the scans using the Deauville five-point scale, blinded to treatment outcome. Forty-five scans were scored as positive (17.3%) and 215 (82.7%) as negative. After a median follow up of 37.0 (2-110) months, 252 patients are alive and eight have died. The 3-year progression-free survival rate was 83% for the whole study population, 28% for patients with interim positive scans and 95% for patients with interim negative scans (P<0.0001). The sensitivity, specificity, and negative and positive predictive values of interim positron emission tomography scans for predicting treatment outcome were 0.73, 0.94, 0.94 and 0.73, respectively. Binary concordance amongst reviewers was good (Cohen's kappa 0.69-0.84). In conclusion, the prognostic role and validity of the Deauville five-point scale for interpretation of interim positron emission tomography scans have been confirmed by the present study.

  13. Development of positron annihilation spectroscopy for characterizing neutron irradiated tungsten

    SciTech Connect

    C.N. Taylor; M. Shimada; D.W. Akers; M.W. Drigert; B.J. Merrill; Y. Hatano

    2013-05-01

    Tungsten samples (6 mm diameter, 0.2 mm thick) were irradiated to 0.025 and 0.3 dpa with neutrons in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Samples were then exposed to deuterium plasma in the tritium plasma experiment (TPE) at 100, 200 and 500ºC to a total fluence of 1 x 1026 m-2. Nuclear reaction analysis (NRA) and Doppler broadening positron annihilation spectroscopy (DB-PAS) were performed at various stages to characterize damage and retention. We present the first known results of neutron damaged tungsten characterized by DB-PAS in order to study defect concentration. Two positron sources, 22Na and 68Ge, probe ~58 µm and through the entire 200 µm thick samples, respectively. DB-PAS results reveal clear differences between the various irradiated samples. These results, and the calibration of DB-PAS to NRA data are presented.

  14. Pumping Electron-Positron Pairs from a Well Potential

    PubMed Central

    Wang, Qiang; Liu, Jie; Fu, Li-bin

    2016-01-01

    In the presence of very deep well potential, electrons will spontaneously occupy the empty embedded bound states and electron-positron pairs are created by means of a non-perturbative tunneling process. In this work, by slowly oscillating the width or depth, the population transfer channels are opened and closed periodically. We find and clearly show that by the non-synchronous ejections of particles, the saturation of pair number in a static super-critical well can be broken, and electrons and positrons can be pumped inexhaustibly from vacuum with a constant production rate. In the adiabatic limit, final pair number after a single cycle has quantized values as a function of the upper boundary of the oscillating, and the critical upper boundaries indicate the diving points of the bound states. PMID:27125998

  15. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    NASA Astrophysics Data System (ADS)

    Alonso, A. M.; Cooper, B. S.; Deller, A.; Cassidy, D. B.

    2016-08-01

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO4 scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO4 for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized soon after production. This is due to the much higher light output for LYSO (75% and 1% of NaI for LYSO and PbWO4 respectively). We conclude that LYSO is an ideal scintillator for single-shot measurements of positronium production and excitation performed using a low-intensity pulsed positron beam.

  16. Dechanneling of Positrons in Disordered Lattices Effect of Anharmonic Potential

    NASA Astrophysics Data System (ADS)

    Abu-Assy, M. K.; El-Ashry, M. Y.; Mohamed, A. A.

    2005-01-01

    Dechanneling of positrons due to lattice disorder has been investigated for two stable configurations of the disordered face-centered cubic(fcc) lattices, Dumb-bell configuration (DBC) and Body-centered interstitial (BCI) for channeled positrons with incident energy (10 200) MeV in Cu single crystal in the planar direction (100). The effects of anharmonic terms in the channeling potential have been considered in the calculations. The calculations covered the transition-channeling probability, dechanneling probability, transmission and dechanneling coefficients. It has been found that the transition-channeling probability from the normal into the disordered region occurs only for the transitions n (normal) → n (disordered). Also the dependence of the transmission and dechanneling coefficients on the incident beam position has been studied by using a planar potential function based on shell structure model and compared with the results of a planar potential based on Lindhard's model.

  17. Pumping Electron-Positron Pairs from a Well Potential

    NASA Astrophysics Data System (ADS)

    Wang, Qiang; Liu, Jie; Fu, Li-Bin

    2016-04-01

    In the presence of very deep well potential, electrons will spontaneously occupy the empty embedded bound states and electron-positron pairs are created by means of a non-perturbative tunneling process. In this work, by slowly oscillating the width or depth, the population transfer channels are opened and closed periodically. We find and clearly show that by the non-synchronous ejections of particles, the saturation of pair number in a static super-critical well can be broken, and electrons and positrons can be pumped inexhaustibly from vacuum with a constant production rate. In the adiabatic limit, final pair number after a single cycle has quantized values as a function of the upper boundary of the oscillating, and the critical upper boundaries indicate the diving points of the bound states.

  18. Open volume in bioadhesive detected by positron annihilation lifetime spectroscopy.

    PubMed

    Rätzke, Klaus; Wiegemann, Maja; Shaikh, Muhammad Qasim; Harms, Stephan; Adelung, Rainer; Egger, Werner; Sperr, Peter

    2010-07-01

    Barnacles attach to a wide variety of surfaces underwater and show substrate-specific adhesion mechanisms. Investigating and understanding these mechanisms is a key for developing new technical adhesives. We expected open volume (porosity) at the sub-nanometre scale to occur in barnacle adhesive. With positron annihilation lifetime spectroscopy (PALS) it is possible to detect porosity at the nanometre scale by determining the lifetime of positrons. This method has not been applied to bioadhesives so far. We showed that PALS is a suitable technique for the investigation of the barnacle base and its adhesive with respect to open volume. The results were interpreted using a standard model adapted from polymers. We thereby estimated pore sizes of 0.5 nm.

  19. Secondary positrons and electrons in the cosmic radiation

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Stephens, S. A.

    1978-01-01

    An improved calculation of the secondary production and equilibrium spectrum of positrons and electrons in the Galaxy in the energy range from 1 MeV to 100 GeV has been performed. This has been done by obtaining an analytic representation of the accelerator data which describes accurately the invariant cross-section of pions, kaons, and their antiparticles from threshold energy to about 1500 GeV. This calculation takes into account the correct angular distribution of electrons in the decay of muons and the effect of nuclei-nuclei collisions. The contributions of beta-decay positrons and knock-on electrons have been included. A comparison of the present calculations with earlier calculations and experiment is presented.

  20. Polarized positrons and electrons at the linear collider

    NASA Astrophysics Data System (ADS)

    Moortgat-Pick, G.; Abe, T.; Alexander, G.; Ananthanarayan, B.; Babich, A. A.; Bharadwaj, V.; Barber, D.; Bartl, A.; Brachmann, A.; Chen, S.; Clarke, J.; Clendenin, J. E.; Dainton, J.; Desch, K.; Diehl, M.; Dobos, B.; Dorland, T.; Dreiner, H. K.; Eberl, H.; Ellis, J.; Flöttmann, K.; Fraas, H.; Franco-Sollova, F.; Franke, F.; Freitas, A.; Goodson, J.; Gray, J.; Han, A.; Heinemeyer, S.; Hesselbach, S.; Hirose, T.; Hohenwarter-Sodek, K.; Juste, A.; Kalinowski, J.; Kernreiter, T.; Kittel, O.; Kraml, S.; Langenfeld, U.; Majerotto, W.; Martinez, A.; Martyn, H.-U.; Mikhailichenko, A.; Milstene, C.; Menges, W.; Meyners, N.; Mönig, K.; Moffeit, K.; Moretti, S.; Nachtmann, O.; Nagel, F.; Nakanishi, T.; Nauenberg, U.; Nowak, H.; Omori, T.; Osland, P.; Pankov, A. A.; Paver, N.; Pitthan, R.; Pöschl, R.; Porod, W.; Proulx, J.; Richardson, P.; Riemann, S.; Rindani, S. D.; Rizzo, T. G.; Schälicke, A.; Schüler, P.; Schwanenberger, C.; Scott, D.; Sheppard, J.; Singh, R. K.; Sopczak, A.; Spiesberger, H.; Stahl, A.; Steiner, H.; Wagner, A.; Weber, A. M.; Weiglein, G.; Wilson, G. W.; Woods, M.; Zerwas, P.; Zhang, J.; Zomer, F.

    2008-05-01

    The proposed International Linear Collider (ILC) is well-suited for discovering physics beyond the Standard Model and for precisely unraveling the structure of the underlying physics. The physics return can be maximized by the use of polarized beams. This report shows the paramount role of polarized beams and summarizes the benefits obtained from polarizing the positron beam, as well as the electron beam. The physics case for this option is illustrated explicitly by analyzing reference reactions in different physics scenarios. The results show that positron polarization, combined with the clean experimental environment provided by the linear collider, allows to improve strongly the potential of searches for new particles and the identification of their dynamics, which opens the road to resolve shortcomings of the Standard Model. The report also presents an overview of possible designs for polarizing both beams at the ILC, as well as for measuring their polarization.

  1. Positron emission tomographic imaging of tumors using monoclonal antibodies

    SciTech Connect

    Zalutsky, M.R.

    1990-12-01

    The overall objective for this research project is to develop methods for utilizing Positron Emission Tomography (PET) to increase the clinical potential of radiolabelled monoclonal antibodies (MAbs). By labeling MAbs with positron-emitting nuclides, it should be possible to quantitate the dynamics of their three-dimensional distribution in vivo. Our long term goals are to apply this approach to investigate the following: normal tissue toxicity; radiation dose to the tumor; and early tumor imaging. The research plans of this proposal include the following specific aims: optimize labeling of MAbs with fluorine 18, bromine 76 and bromine 75; label MAb Mel-14 (reactive against human gliomas and melanomas) and its Fab and F(ab{prime}){sub 2} fragments while retaining immunoreactivity; determine the distribution of Mel-14 in athymic mice bearing human gliomas; determine pharmacokinetics of Mel-14 in nonhuman primates. Experiments with another MAb, TP-1, and iodine 124 and 131 are also planned. 8 figs.

  2. Correlations in laser-induced electron-positron pair creation

    SciTech Connect

    Krajewska, K.; Kaminski, J. Z.

    2011-09-15

    Probability rates of electron-positron pair creation in head-on laser-beam-proton collisions are investigated, using an exact treatment of the colliding proton as a finite-mass particle. We observe that the recoil effects become more important when passing from the perturbative multiphoton regime to the nonperturbative above-threshold regime of laser-matter coupling. Thus we concentrate on the latter case. In this regime, our detailed analysis shows that energy supplied by the colliding proton makes the process more effective, and that the electrons and positrons that are created during the collision are more energetic than in the case when the momentum transfer from the proton is neglected. A number of similarities to above-threshold atomic ionization are also illustrated.

  3. Nonlinear Electromagnetic Waves in a Degenerate Electron-Positron Plasma

    NASA Astrophysics Data System (ADS)

    El-Labany, S. K.; El-Taibany, W. F.; El-Samahy, A. E.; Hafez, A. M.; Atteya, A.

    2015-08-01

    Using the reductive perturbation technique (RPT), the nonlinear propagation of magnetosonic solitary waves in an ultracold, degenerate (extremely dense) electron-positron (EP) plasma (containing ultracold, degenerate electron, and positron fluids) is investigated. The set of basic equations is reduced to a Korteweg-de Vries (KdV) equation for the lowest-order perturbed magnetic field and to a KdV type equation for the higher-order perturbed magnetic field. The solutions of these evolution equations are obtained. For better accuracy and searching on new features, the new solutions are analyzed numerically based on compact objects (white dwarf) parameters. It is found that including the higher-order corrections results as a reduction (increment) of the fast (slow) electromagnetic wave amplitude but the wave width is increased in both cases. The ranges where the RPT can describe adequately the total magnetic field including different conditions are discussed.

  4. Elastic positron-cadmium scattering at low energies

    SciTech Connect

    Bromley, M. W. J.; Mitroy, J.

    2010-05-15

    The elastic and annihilation cross sections for positron-cadmium scattering are reported up to the positronium-formation threshold (at 2.2 eV). The low-energy phase shifts for the elastic scattering of positrons from cadmium were derived from the bound and pseudostate energies of a very large basis configuration-interaction calculation of the e{sup +}-Cd system. The s-wave binding energy is estimated to be 126{+-}42 meV, with a scattering length of A{sub scat}=(14.2{+-}2.1)a{sub 0}, while the threshold annihilation parameter, Z{sub eff}, was 93.9{+-}26.5. The p-wave phase shift exhibits a weak shape resonance that results in a peak Z{sub eff} of 91{+-}17 at a collision energy of about 490{+-}50 meV.

  5. Langmuir rogue waves in electron-positron plasmas

    SciTech Connect

    Moslem, W. M.

    2011-03-15

    Progress in understanding the nonlinear Langmuir rogue waves which accompany collisionless electron-positron (e-p) plasmas is presented. The nonlinearity of the system results from the nonlinear coupling between small, but finite, amplitude Langmuir waves and quasistationary density perturbations in an e-p plasma. The nonlinear Schroedinger equation is derived for the Langmuir waves' electric field envelope, accounting for small, but finite, amplitude quasistationary plasma slow motion describing the Langmuir waves' ponderomotive force. Numerical calculations reveal that the rogue structures strongly depend on the electron/positron density and temperature, as well as the group velocity of the envelope wave. The present study might be helpful to understand the excitation of nonlinear rogue pulses in astrophysical environments, such as in active galactic nuclei, in pulsar magnetospheres, in neutron stars, etc.

  6. What could we learn from a sharply falling positron fraction?

    SciTech Connect

    Delahaye, Timur; Kotera, Kumiko; Silk, Joseph

    2014-10-20

    Recent results from the AMS-02 data have confirmed that the cosmic-ray positron fraction increases with energy between 10 and 200 GeV. This quantity should not exceed 50%, and it is hence expected that it will either converge toward 50% or fall. We study the possibility that future data may show the positron fraction dropping down abruptly to the level expected with only secondary production, and forecast the implications of such a feature in term of possible injection mechanisms that include both dark matter and pulsars. Were a sharp steepening to be found, rather surprisingly, we conclude that pulsar models would do at least as well as dark matter scenarios in terms of accounting for any spectral cut-off.

  7. Laser-assisted positron-impact ionization of atomic hydrogen.

    PubMed

    Pan, Juan; Li, Shu-Min; Berakdar, Jamal

    2007-03-15

    We study the ionization of atomic hydrogen by a fast positron in the presence of an external linearly polarized laser field. We concentrate on the limit of a small momentum transfer and describe the fast positron's continuum states by Volkov wave functions. The ejected electron is described by a Coulomb-Volkov wave function. We are limited to small laser intensities such that the dressed state of the target is treatable within the time-dependent perturbation theory, even though the laser intensity is still quite high by laboratory standards. Numerical results for the triply differential cross sections and their dependencies on laser-field parameters are discussed and compared with the results of laser-assisted ionization by electron impact.

  8. Pure hemidystonia with basal ganglion abnormalities on positron emission tomography

    SciTech Connect

    Perlmutter, J.S.; Raichle, M.E.

    1984-03-01

    We present a patient with hemidystonia and an abnormality of the contralateral basal ganglion seen only with positron emission tomography. A 50-year-old sinistral man suffered minor trauma to the right side of his head and neck. Within 20 minutes he developed paroxysmal intermittent dystonic posturing of his right face, forearm, hand, and foot, with weaker contractions of the left foot, lasting several seconds and recurring every few minutes. Neurological findings between spells were normal. The following were also normal: electrolyte, calcium, magnesium, and arterial blood gas levels, and findings of drug screen, cerebrospinal fluid examination, electroencephalography with nasopharyngeal leads, computed tomographic scanning (initially and four weeks later), and cerebral angiography. Positron emission tomographic scanning revealed abnormalities in the left basal ganglion region, including decreased oxygen metabolism, decreased oxygen extraction, increased blood volume, and increased blood flow.

  9. Calculation of the positron annihilation rate in PsH with the positronic extension of the explicitly correlated nuclear-electronic orbital method.

    PubMed

    Pak, Michael V; Chakraborty, Arindam; Hammes-Schiffer, Sharon

    2009-04-23

    The nuclear-electronic orbital explicitly correlated Hartree-Fock (NEO-XCHF) method is modified and extended to study electron-positron quantum systems. The NEO-XCHF method is more computationally efficient than the explicitly correlated methods previously applied to positron systems because only the electron-positron dynamical correlation is treated explicitly in NEO-XCHF. As a result, the form of the wave function is much simpler with fewer parameters, and the variational optimization of the molecular orbital parameters is performed through an iterative scheme rather than a stochastic optimization. The NEO-XCHF approach is used to calculate the positron annihilation rate for positronium hydride (PsH). The resulting annihilation rate for PsH is within 20% of the most accurate values available and is calculated at a fraction of the computational cost. These results suggest that qualitatively accurate positron annihilation rates can be calculated treating only electron-positron correlation explicitly, leading to significant computational savings by neglecting electron-electron dynamical correlation. Thus, the NEO-XCHF approach could potentially enable the calculation of qualitatively accurate positron annihilation rates for larger positron systems.

  10. Differential cross sections for positron-xenon elastic scattering

    SciTech Connect

    Marler, J. P.; Surko, C. M.; McEachran, R. P.; Stauffer, A. D.

    2006-06-15

    Absolute measurements of differential cross sections for the elastic scattering of positrons from xenon are made at 2, 5 and 8 eV using a trap-based beam and the technique of measuring scattering cross sections in a strong magnetic field. Calculations are carried out using the relativistic Dirac equations with a static plus polarization potential. Generally good absolute agreement is found between experiment and theory.

  11. Principles and clinical applications of positron emission tomography.

    PubMed

    Gardner, S F; Green, J A; Bednarczyk, E M; Farnett, L; Miraldi, F

    1992-06-01

    The basics of positron emission tomography (PET) are presented, including the physics, instrumentation, and radiopharmaceuticals involved; the clinical and research applications; and the cost. In PET, organic molecules labeled with positron-emitting radionuclides are injected or inhaled, and the high-energy photons produced by annihilation events are detected by paired, integrated crystal detectors. A computer uses the lines of origin of these photons to reconstruct a three-dimensional map of a functioning organ system. The positron-emitting radionuclides most often used are carbon 11, oxygen 15, nitrogen 13, fluorine 18, and rubidium 82. PET imaging centers usually consist of a cyclotron facility, a radiochemistry facility, a PET scanner, and computers for image reconstruction. Radiopharmaceuticals used in PET may be divided into blood flow-imaging agents, metabolic imaging agents, and drug receptor-imaging agents. Although PET is still primarily a research tool, it has shown diagnostic potential in neurology, cardiology, and oncology. It has also shown promise as a tool for pharmacologic assessment, as in studies of the effects of the fluorinated quinolones on cerebral blood flow and glucose metabolism. PET may become important in drug development because it yields specific information relatively noninvasively. A single study carries an average break-even price tag of $1500-$2000; rigorous cost-benefit analyses should be conducted before society is asked to subsidize such costs. Positron emission tomography is a frontier technology for which valuable clinical applications are being discovered. Pharmacists can contribute enormously to PET applications and at the same time establish a unique subspecialty for the profession.

  12. Positron-emitting radioligands for imaging neuroleptic receptors

    SciTech Connect

    Arnett, C.D.; Fowler, J.S.; Wolf, A.P.; Shiue, C.Y.; Logan, J.

    1985-01-01

    A series of /sup 18/F-labeled butyrophenones (benperidol, haloperidol, spiroperidol and N-methylspiroperidol) were evaluated in baboons and rats with respect to potential utility as radioligands for studying neuroleptic receptors in the living human brain by positron emission tomography. These compounds were administered to baboons, and the radioactivity distributions to the striatum, and to the cerebellum were determined by PET at times up to 8 hours after isotope injection. 4 refs. (DT)

  13. Interpretation of the cosmic ray positron and antiproton fluxes

    NASA Astrophysics Data System (ADS)

    Lipari, Paolo

    2017-03-01

    The spectral shape of cosmic ray positrons and antiprotons has been accurately measured in the broad kinetic energy range 1-350 GeV. In the higher part of this range (E ≳30 GeV ), the e+ and p ¯ are both well described by power laws with spectral indices γe+≃2.77 ±0.02 and γp ¯≃2.78 ±0.04 that are approximately equal to each other and to the spectral index of protons. In the same energy range, the positron-antiproton flux ratio has the approximately constant value 2.04 ±0.04 , that is consistent with being equal to the ratio e+/p ¯ calculated for the conventional mechanism of production, where the antiparticles are created as secondaries in the inelastic interactions of primary cosmic rays with interstellar gas. The positron-antiproton ratio at lower energy is significantly higher (reaching a value e+/p ¯≈100 for E ≈1 GeV ), but, in the entire energy range 1-350 GeV, the flux ratio is consistent with being equal to the ratio of the production rates in the conventional mechanism, as the production of low-energy antiprotons is kinematically suppressed in collisions with a target at rest. These results strongly suggest that cosmic ray positrons and antiprotons have a common origin as secondaries in hadronic interactions. This conclusion has broad implications for the astrophysics of cosmic rays in the Galaxy.

  14. Transparency of an instantaneously created electron-positron-photon plasma

    NASA Astrophysics Data System (ADS)

    Bégué, D.; Vereshchagin, G. V.

    2014-03-01

    The problem of the expansion of a relativistic plasma generated when a large amount of energy is released in a small volume has been considered by many authors. We use the analytical solution of Bisnovatyi-Kogan and Murzina for the spherically symmetric relativistic expansion. The light curves and the spectra from transparency of an electron-positron-photon plasma are obtained. We compare our results with the work of Goodman.

  15. Inelastic collisions of positrons with one-valence-electron targets

    NASA Technical Reports Server (NTRS)

    Abdel-Raouf, Mohamed Assad

    1990-01-01

    The total elastic and positronium formation cross sections of the inelastic collisions between positrons and various one-valence-electron atoms, (namely hydrogen, lithium, sodium, potassium and rubidium), and one-valence-electron ions, (namely hydrogen-like, lithium-like and alkaline-earth positive ions) are determined using an elaborate modified coupled-static approximation. Special attention is devoted to the behavior of the Ps cross sections at the energy regions lying above the Ps formation thresholds.

  16. Positron brain imaging--normal patterns and asymmetries

    SciTech Connect

    Finklestein, S.; Alpert, N.M.; Ackerman, R.H.; Correia, J.A.; Buonanno, F.S.; Chang, J.; Brownell, G.L.; Taveras, J.M.

    1982-07-01

    Regional brain physiology was investigated in 11 normal resting right-handed subjects using positron emission tomography. Cerebral blood flow was studied in all subjects. Cerebral oxygen metabolism was studied in six subjects, and cerebral glucose metabolism was also studied in one subject. In five subjects, physiological activity was higher in left frontotemporal regions than right. These findings may be related to structural cerebral asymmetries or to activation of brain language centers.

  17. Technology related parameters affecting quantification in positron emission tomography imaging.

    PubMed

    Visvikis, D; Turzo, A; Bizais, Y; Cheze-Le Rest, C

    2004-07-01

    Some of the issues associated with positron emission tomography (PET) technology which still pose challenges for the recovery of quantitative images are discussed. Through these issues reference to what is today considered as the 'gold standard' in quantitative PET imaging is also presented. A brief comparison of 2-D and 3-D PET is given, together with a short discussion of combined PET/CT imaging devices.

  18. Design and performance of a positron-sensitive surgical probe

    NASA Astrophysics Data System (ADS)

    Liu, Fang

    We report the design and performance of a portable positron-sensitive surgical imaging probe. The probe is designed to be sensitive to positrons and capable of rejecting background gammas including 511 keV. The probe consists of a multi-anode PMT and an 8 x 8 array of thin 2 mm x 2 mm plastic scintillators coupled 1:1 to GSO crystals. The probe uses three selection criteria to identify positrons. An energy threshold on the plastic signals reduces the false positron signals in the plastic due to background gammas; a second energy threshold on the PMT sum signal greatly reduces background gammas in the GSO. Finally, a timing window accepts only 511 keV gammas from the GSO that arrive within 15 ns of the plastic signals, reducing accidental coincidences to a negligible level. The first application being investigated is sentinel lymph node (SLN) surgery, to identify in real-time the location of SLNs in the axilla with high 18F-FDG uptake, which may indicate metastasis. Our simulations and measurements show that the probe's pixel separation ability in terms of peak-to-valley ratio is ˜3.5. The performance measurements also show that the 64-pixel probe has a sensitivity of 4.7 kcps/muCi using optimal signal selection criteria. For example, it is able to detect in 10 seconds a ˜4 mm lesion with a true-to-background ratio of ˜3 at a tumor uptake ratio of ˜8:1. The signal selection criteria can be fine-tuned, either for higher sensitivity, or for a higher image contrast.

  19. Current and future technological trends in positron emission tomography.

    PubMed

    Karp, J S; Freifelder, R

    1992-04-01

    Current trends in positron emission tomography (PET) instrumentation are examined, with an emphasis on providing information suitable to the prospective PET user. Basic principles underlying PET are explained and information on performance measurements, techniques, and quantitation are given in order to allow the user to compare and contrast different types of PET scanners. These scanner designs are described. Specific examples are given and the combination of PET with other modalities is discussed.

  20. Resonances in positron-hydrogen scattering in dense quantum plasmas

    SciTech Connect

    Jiang, Zishi; Zhang, Yong-Zhi; Kar, Sabyasachi

    2015-05-15

    We have investigated the S-wave resonance states in positron-hydrogen system embedded in dense quantum plasmas using Hylleraas-type wave functions within the framework of the stabilization method. The effect of quantum plasmas has been incorporated using the exponential-cosine-screened Coulomb (modified Yukawa-type) potential. Resonance parameters (both position and width) below the Ps n = 2 threshold are reported as functions of plasma screening parameters.

  1. Collisionless Reconnection in an Electron-Positron Plasma

    SciTech Connect

    Bessho, N.; Bhattacharjee, A.

    2005-12-09

    Electromagnetic particle-in-cell simulations of fast collisionless reconnection in a two-dimensional electron-positron plasma (without an equilibrium guide field) are presented. A generalized Ohm's law in which the Hall current cancels out exactly is given. It is suggested that the key to fast reconnection in this plasma is the localization caused by the off-diagonal components of the pressure tensors, which produce an effect analogous to a spatially localized resistivity.

  2. Magnetic resonance imaging and positron emission tomography of band heterotopia.

    PubMed

    Miura, K; Watanabe, K; Maeda, N; Matsumoto, A; Kumagai, T; Ito, K; Kato, T

    1993-01-01

    A case of band heterotopia was reported with findings of positron emission tomography (PET). The patient was an 8-year-old girl who had mild mental retardation and intractable partial epilepsy. Her MRI showed another diffuse layer of gray matter underlying the normal-looking cortex and separated from it by an apparently normal layer of white matter. PET scan with [18F]fluorodeoxyglucose revealed that band heterotopia had the same degree of glucose metabolism as that of the overlying cortex.

  3. ECC study in positron impact ionization in molecular hydrogen

    NASA Astrophysics Data System (ADS)

    Campeanu, R. I.; Zohouri Haghian, N.

    2012-12-01

    The electron capture to the continuum phenomenon in positron impact ionization of molecular hydrogen is studied with the distorted wave Born approximation. Our theoretical model produces results which are in better agreement with the experiment than the more elaborate models of [J. Fiol, V.D. Rodriguez, R.O. Barrachina, J. Phys. B: At. Mol. Opt. Phys. 34, 933 (2001)] and [A. Benedek, R.I. Campeanu, J. Phys. B: At. Mol. Opt. Phys. 40, 1589 (2007)] previously employed in this study.

  4. Positron Impact Ionization in Noble Gas Atoms and Diatomic Molecules

    NASA Astrophysics Data System (ADS)

    Marler, J. P.

    2005-05-01

    Results are presented for absolute positronium formation and direct ionization by positron impact on Ne, Ar, Kr, Xe, N2, CO and O2 at energies from threshold up to 90 eV. The experiments use a high-resolution, trap-based positron beam and exploit the properties of positron orbits in a magnetic field [1]. Results for the noble gases are compared with theoretical predictions and with measurements obtained using a significantly different method [2]. Results for diatomic molecules are compared to other available measurements and theoretical calculations where available. There is generally good agreement between the experimental measurements, providing an important benchmark for theoretical calculations. Intriguing features in Ar and O2 will be discussed. [1] J.P. Sullivan, S.J. Gilbert, J.P. Marler, R.G. Greaves, S.J. Buckman and C.M. Surko., Phys. Rev. A. 66, 042708 (2002) [2] J.P. Marler, J.P. Sullivan and C.M. Surko, Phys. Rev. A (2005), in press.

  5. Positron Anomaly in Galactic Cosmic Rays: Constraining Dark Matter Contribution

    NASA Astrophysics Data System (ADS)

    Sagdeev, Roald; Malkov, Mikhail; Diamond, Patrick

    2016-10-01

    An explanation of the unexpected rise in the positron fraction of the cosmic ray (CR) leptonic energy spectrum, is proposed. It is argued that the e+/- spectra are different because they are accelerated by a charge-sign selective mechanism. This premise was hinted at by a recent result from the AMS-02 spectrometer that revealed a difference between e+ and antiproton spectra, which both are secondary CRs but of the opposite charges. The new mechanism extends the diffusive shock acceleration (DSA) to make it charge-sign selective. The DSA, operating in Galactic supernova remnant (SNR) shocks, is held responsible for the production of the bulk of the CRs. The new mechanism was found to account for the positron data with an excellent agreement, except in a limited energy range between 100-300 GeV. In this range, the data exceed the theoretical prediction systematically, thus opening a window for a contribution from dark matter decay or annihilation as well as nearby pulsars. The charge-sign selectivity of the DSA arises from an electric field induced by the CR protons illuminating the neutral gas clumps in the SNR surroundings. The electric field expels positrons from the clump but traps electrons and secondary antiprotons, thus suppressing their acceleration in such SNRs. Work supported by NASA ATP-program under Grant NNX14AH36G, and by the US Department of Energy under Award No. DE-FG02-04ER54738.

  6. [Methods and clinical applications of positron emission tomography in endocrinology].

    PubMed

    De Landsheere, C; Lamotte, D

    1990-01-01

    Positron emission tomography (PET) allows to detect in coincidence photons issued from annihilation between positrons and electrons nearby situated. Tomographic detection (plane by plane) and tomographic reconstruction will lead to the quantitation of radioactive distribution per voxel, in the organ of interest. Recent tomographs can acquire simultaneously several transaxial slices, with a high sensitivity and a spatial resolution of 3-5 mm. Commonly used positron emitters have a short half-life: 2, 10, 20 and 110 min for 150, 13N, 11C and 18F, respectively. The use of these isotopes requires on line production of radionuclides and synthesis of selected molecules. In endocrinology, PET allows among others to study noninvasively the receptor density of hormone-dependent neoplasms such as breast, uterus, prostate tumors and prolactinomas. These last tumors represent a particular entity because of several combined characteristics: high turnover rate of amino acids, high density of dopaminergic receptors and response to bromocriptine (analogue of dopamine inhibiting the secretion of prolactin) in relation to the level of receptors. Because PET permits to evaluate the density of dopaminergic receptors and the metabolism of amino acids, theoretical response of the prolactinoma to bromocriptine can be predicted, the achieved therapeutic efficacy can be estimated and the long-term follow up of tumor growth can be assessed. This example illustrates the clinical value of PET in endocrinology.

  7. Design and implementation of a real-time positron imager

    NASA Astrophysics Data System (ADS)

    Naik, Pranab S.; Beling, Christopher D.; Fung, Stevenson

    2004-05-01

    In this paper we are going to present the first real-time S-parameter positron imager. This is a useful tool in solid state technology for mapping the lateral defect types and concentrations on a material sample. This technology has been developed for two major categories of researchers, the first being those that have a focused low energy positron beam and second those that do not. Here we describe the design and implementation of a real-time automated scanning system that rasters a sample surface with a 0.5mm diameter positron source (or beam focus) so as to give an S-parameter image of a sample. The source (or beam) rasters across a region of a semiconductor sample in rectilinear motion while gamma ray energies Eγ are processed using a standard HP Ge spectroscopy system and a 14 bit nuclear ADC. Two other ADCs are used to obtain the x, y coordinate data corresponding to each event by storing voltage pulses from the x & y stepper motor drives (or saddle coil currents) gated with the event pulses. Using these event data triplets (x, y, Eγ) the S-parameter is computed in real time for each pixel region and is used to refresh a color image display on the screen coordinates. Optimal use is made of processing time and the system resources. This user-friendly system is efficient for producing high resolution S-parameter images of the sample. (patent pending 2003)

  8. Electron and Positron Scattering from C3H6 Isomers

    NASA Astrophysics Data System (ADS)

    Makochekanwa, Casten; Sueoka, Osamu; Kimura, Mineo; Hoshino, Masamitsu; Tanaka, Takahiro; Kitajima, Masashi; Tanaka, Hiroshi

    2004-09-01

    Hydrocarbons play an important role in high temperature plasmas in Tokamak fusion devices in plasma processing and many other fields [1]. In this paper we report experiments for 0.4-1000 eV electron and 0.2-1000 eV positron total cross sections (TCS) measured using a linear time-of-flight apparatus [2], and electron differential cross sections (DCS) for elastic, vibrational and electronic excitations covering the ranges 1.5 to 100 eV and 15 deg to 130 deg, measured using the crossed beam and relative flow method [3]. The continuum multiple scattering (CMS) [4] calculations have also been performed for the theoretical analysis of the observed features in our cross sections. We observe the isomer effect in both electron and positron TCSs and DCSs. The presence of a dipole moment in propene molecules shows up in enhanced forward scattering in DCSs, leading to larger TCSs and integral cross sections compared to cyclopropane at energies less than 20 eV. However, both electron and positron TCSs for these two molecules nearly equal each other above 100 eV, i.e. the molecular size effect. [1] W. L. Moragn, Adv. At. Mol. Opt. Phys. 43, 79 (2000). [2] O. Sueoka, S. Mori and A. Hamada, J. Phys. B 27, 1453 (1994). [3] H. Tanaka, L. Boesten, D. Matsunaga and T. Kudo, J. Phys. B 21, 1255 (1988). [4] M. Kimura and H. Sato, Comments At. Mol. Phys. 26, 333 (1991).

  9. Induced Positron Annihiliation Investigation of Cadmium Zinc Telluride Crystal Microstructures

    SciTech Connect

    D. W. Akers

    2005-06-01

    Cadmium-Zinc-Telluride (CZT) crystals are used in semiconductor radiation detectors for the detection of x-ray and gamma radiation. However, production of detector grade crystals is difficult as small variations in compositional uniformity and primarily the zinc content can significantly affect the ability of the CZT crystal to function as a radiation detector. Currently there are no known nondestructive methods that can be used to identify detector grade crystals. The current test method is to fabricate and test the detector to determine if the crystal is sufficiently uniform and of the correct composition to be considered a detector grade crystal. Consequently, nondestructive detection methods are needed to identify detector grade crystals prior to the fabrication process. The purpose of this feasibility study was to perform a preliminary assessment of the ability of several new, nondestructive technologies based on Induced Positron Annihilation (IPA) to determine if detector grade CZT crystals can be identified. Results of measurements performed on specimens from Fisk University and EV Products, Inc. indicate that both the near surface Distributed Source Positron Annihilation (up to 3 mm penetration) and the volumetric Photon Induced Positron Annihilation methods may be suitable for determining CZT crystal quality. Further work on CZT crystals with a broader range of compositions and detector characteristics is needed to provide a well defined, calibrated, method for assessing CZT crystal quality.

  10. Calculations of the Probability of Positron Trapping by a Vacancy in a Metal and the Estimation of the Vacancy Contribution to the Work Function of Electrons and Positrons

    NASA Astrophysics Data System (ADS)

    Babich, A. V.; Pogosov, V. V.; Reva, V. I.

    2016-03-01

    The probabilities of the localization of positrons in monovacancies of Al and Cu have been calculated as functions of the energy and temperature. The vacancy was simulated by a void with a radius equal to the radius of the Wigner—Seitz cell in the model of stable jellium. Using the Fermi—Dirac golden rule for transitions, the formula for the rate of positron trapping by a vacancy has been derived as the function of the positron energy. For the thermalized positrons, the rate of localization near the triple point proved to be, on the order of magnitude, close to the rate of annihilation. Within the framework of our previously proposed models, the contribution of vacancies to the work function of electrons and positrons has been demonstrated based on the example of Al. The physical situations where the vacancy effect can manifest have been considered.

  11. The value of positron emission tomography scanning in the detection of subclinical metastatic melanoma.

    PubMed

    Acland, K M; O'Doherty, M J; Russell-Jones, R

    2000-04-01

    We have undertaken a retrospective analysis of all positron emission tomography (PET) scans carried out at St Thomas' Hospital, London, since 1994 to establish the sensitivity and specificity of this radiologic technique in cutaneous malignant melanoma. In particular, we have identified those patients with primary cutaneous malignant melanoma in whom PET scanning revealed in-transit or regional spread to nodes and those patients with known regional spread in whom PET scanning revealed distant metastases. We defined our false-negative results as a negative scan result with positive histology or subsequent clinical progression of disease. False-positive results were defined as a suspect scan with negative histology or no subsequent progression of disease. PET scanning had an overall sensitivity of 78% and specificity of 87%; however, subset analysis (M. D. Anderson staging system) showed a sensitivity of 50% for stage I disease (34 patients and 35 scans) and 33% for stage II disease (9 patients and 9 scans) with specificities of 87% and 100%, respectively. For stage III disease (16 patients and 17 scans), PET showed a sensitivity of 93% and specificity of 50%. Overall, 35% of patients with true-positive scans had their disease restaged. We can conclude therefore that PET is valuable as a staging procedure in patients with known regional spread but is suboptimal in the prediction of outcome in stage I or stage II disease.

  12. Positron-electron correlation-polarization potentials for the calculation of positron collisions with atoms and molecules*

    NASA Astrophysics Data System (ADS)

    Franz, Jan

    2017-02-01

    We present correlation-polarization potentials for the calculation of scattering cross sections of positrons with atoms and molecules. The potentials are constructed from a short-range correlation term and a long-range polarization term. For the short-range correlation term we present four different potentials that are derived from multi-component density functionals. For the long-range polarization term we employ a multi-term expansion. Quantum scattering calculations are presented for low energy collisions of positrons with two atomic targets (argon and krypton) and two molecular targets (nitrogen and methane). For collision energies below the threshold for Positronium formation our calculations of scattering cross sections are in good agreement with recent data sets from experiments and theory. Contribution to the Topical Issue "Low-Energy Interactions related to Atmospheric and Extreme Conditions", edited by S. Ptasinska, M. Smialek-Telega, A. Milosavljevic and B. Sivaraman.

  13. Positron acceleration by sheath field in ultra-intense laser–solid interactions

    NASA Astrophysics Data System (ADS)

    Yan, Yonghong; Wu, Yuchi; Chen, Jia; Yu, Minghai; Dong, Kegong; Gu, Yuqiu

    2017-04-01

    A positron production experiment was performed by irradiating an ultra-intense picosecond laser on solid tantalum targets. Quasi-monoenergetic positron beams were obtained owing to the sheath field on the back of the target. The experiment shows that the peak energy of the positron spectrum has a linear relation with the reciprocal of the target diameter. A simple analytical model of the sheath field was constructed to explain the experimental data, which predicts the positron peak energy in terms of the target diameter and hot electron parameters. Based on the field model, Monte Carlo simulations were conducted to treat the positron production and acceleration self-consistently. The simulated spectra are in good agreement with most experiment results. The disagreement of the 1 mm diameter data reveals that the hot electron propagation along the target flank surface plays an important role in the sheath field set up. Several aspects involved in the positron acceleration are discussed.

  14. The effect of direct electron-positron pair production on relativistic feedback rates

    NASA Astrophysics Data System (ADS)

    Vodopiyanov, I. B.; Dwyer, J. R.; Cramer, E. S.; Lucia, R. J.; Rassoul, H. K.

    2015-01-01

    Runaway electron avalanches developing in thunderclouds in high electric field become self-sustaining due to relativistic feedback via the production of backward propagating positrons and backscattered X-rays. To date, only positrons created from pair production by gamma rays interacting with the air have been considered. In contrast, direct electron-positron pair production, also known as "trident process," occurs from the interaction of energetic runaway electrons with atomic nuclei, and so it does not require the generation of a gamma ray mediator. The positrons produced in this process contribute to relativistic feedback and become especially important when the feedback factor value approaches unity. Then the steady state flux of runaway electrons increases significantly. In certain cases, when the strong electrostatic field forms in a narrow area, the direct positrons become one of processes dominating relativistic feedback. Calculations of the direct positron production contribution to relativistic feedback are presented for different electric field configurations.

  15. Studies of Oxidation of the Cu(100) Surface Using Low Energy Positrons

    SciTech Connect

    Fazleev, N. G.; Maddox, W. B.; Nadesalingam, M.; Rajeshwar, K.; Weiss, A. H.

    2009-03-10

    Changes in the surface of an oxidized Cu(100) single crystal resulting from vacuum annealing have been investigated using positron annihilation induced Auger electron spectroscopy (PAES). PAES measurements show a large increase in the intensity of the positron annihilation induced Cu M{sub 2,3}VV Auger peak as the sample is subjected to a series of isochronal anneals in vacuum up to annealing temperature 300 deg. C. The intensity then decreases monotonically as the annealing temperature is increased to {approx}600 deg. C. Experimental PAES results are analyzed by performing calculations of positron surface states and annihilation probabilities of surface-trapped positrons with relevant core electrons taking into account the charge redistribution at the surface, surface reconstructions, and electron-positron correlations effects. Possible explanation for the observed behavior of the intensity of positron annihilation induced Cu M{sub 2,3}VV Auger peak with changes of the annealing temperature is proposed.

  16. Apparatus for the analysis of surfaces in gas environments using Positron Spectroscopy

    NASA Astrophysics Data System (ADS)

    Satyal, Suman; Lim, Lawrence; Joglekar, Prasad; Kalaskar, Sushant; Shastry, Karthik; Weiss, Alexander

    2011-03-01

    Positron spectroscopy performed with low energy beams can provide highly surface specific information due to the trapping of positrons in an image potential surface state at the time of annihilation. Here we present design details of a new positron beam system for the analysis of surfaces gas environments. The new system will employ differential pumping to transport the positrons most of the way from the source to the sample under high vacuum. The positrons will then be transported through a thin gas layer surrounding the sample. The positrons will be implanted into the sample at energies less than ~ 10 keV ensuring that a large fraction will diffuse back to the surface before annihilation. The Elemental content of the surface interacting with the gas environment will then be determined from the Doppler broadened gamma spectra. Welch Y1100, NSF DMR 0907679.

  17. Sgr A* as Source of the Positrons Observed in the Galactic Center Region

    NASA Astrophysics Data System (ADS)

    Jean, Pierre; Guessoum, Nidhal; Ferrière, Katia

    2017-01-01

    We explore the possibility that a substantial fraction of the positrons observed to annihilate in the central region of our Galaxy come from the supermassive black hole Sgr A* that lies at the center. This idea was proposed by several authors, but the propagation of the emitted positrons into the bulge and beyond remained a serious problem for models of the origin of GC positrons. We assume models of positron production with different energies. The propagation of positrons from their production site is followed in detail with Monte-Carlo simulations, taking into account the physical conditions of the propagation regions as well as various physical interactions. Using the known physics of positron annihilation in astrophysical environments, we calculate the properties of the annihilation emission (time evolution and spatial distribution) for the different models under consideration. We present the results of these simulations and the conclusions/constraints that can be inferred from them.

  18. Surfaces of colloidal PbSe nanocrystals probed by thin-film positron annihilation spectroscopy

    SciTech Connect

    Chai, L.; Schut, H.; Schaarenburg, L. C. van; Eijt, S. W. H.; Al-Sawai, W.; Barbiellini, B.; Bansil, A.; Gao, Y.; Houtepen, A. J.; Mijnarends, P. E.; Huis, M. A. van; Ravelli, L.; Egger, W.; Kaprzyk, S.

    2013-08-01

    Positron annihilation lifetime spectroscopy and positron-electron momentum density (PEMD) studies on multilayers of PbSe nanocrystals (NCs), supported by transmission electron microscopy, show that positrons are strongly trapped at NC surfaces, where they provide insight into the surface composition and electronic structure of PbSe NCs. Our analysis indicates abundant annihilation of positrons with Se electrons at the NC surfaces and with O electrons of the oleic ligands bound to Pb ad-atoms at the NC surfaces, which demonstrates that positrons can be used as a sensitive probe to investigate the surface physics and chemistry of nanocrystals inside multilayers. Ab initio electronic structure calculations provide detailed insight in the valence and semi-core electron contributions to the positron-electron momentum density of PbSe. Both lifetime and PEMD are found to correlate with changes in the particle morphology characteristic of partial ligand removal.

  19. Positron production at extreme light infrastructure – nuclear physics (ELI-NP)

    SciTech Connect

    Oprisa, A. Balascuta, S. Ur, C. A.

    2015-02-24

    Applied and material physics studies with positron beams of Fermi–surfaces, defects, interfaces etc. offer excellent diagnostics tools. At ELI-NP, an intense γ beam of about 10{sup 11} photons/s with energies up to 3.5 MeV will be used to generate a positron beam via pair production in a tungsten converter target. To obtain a high intensity beam of moderated positrons the design of the positron source is of high importance. The design of a dedicated positron source at ELI–NP is being investigated based on extensive GEANT4 simulations. The goal of the simulations is to optimize the geometry of the target and the gamma beam collimation. We present here the characteristics of the positron beam obtained for different geometries of the converter target.

  20. Computational Study of Positron-Monovacancy Interaction in d-Block Metals

    NASA Astrophysics Data System (ADS)

    Ishibashi, Shoji

    2015-08-01

    The positron-monovacancy interaction in d-block metals (except for Mn, Tc, and Hg) has been studied by the two-component density-functional-theory formalism [E. Boroński and R. M. Nieminen, http://dx.doi.org/10.1103/PhysRevB.34.3820, Phys. Rev. B 34, 3820 (1986)]. On the unrelaxed structure, the positron lifetime calculated with the presence of a positron is generally longer than that obtained neglecting the positron effect. When the atomic positions are relaxed, the difference is widened, especially for the group V metals. The inward relaxation of the atoms surrounding the monovacancy is suppressed when the positron effect is taken into account. The difference in the positron lifetime can be also related to the bulk modulus and the cohesive energy.

  1. Positron interactions with water–total elastic, total inelastic, and elastic differential cross section measurements

    SciTech Connect

    Tattersall, Wade; Chiari, Luca; Machacek, J. R.; Anderson, Emma; Sullivan, James P.; White, Ron D.; Brunger, M. J.; Buckman, Stephen J.; Garcia, Gustavo; Blanco, Francisco

    2014-01-28

    Utilising a high-resolution, trap-based positron beam, we have measured both elastic and inelastic scattering of positrons from water vapour. The measurements comprise differential elastic, total elastic, and total inelastic (not including positronium formation) absolute cross sections. The energy range investigated is from 1 eV to 60 eV. Comparison with theory is made with both R-Matrix and distorted wave calculations, and with our own application of the Independent Atom Model for positron interactions.

  2. Pre-clinical and Clinical Evaluation of High Resolution, Mobile Gamma Camera and Positron Imaging Devices

    DTIC Science & Technology

    2010-10-01

    04-1-0594 TITLE: Pre-clinical and Clinical Evaluation of High Resolution, Mobile Gamma Camera and Positron Imaging Devices PRINCIPAL...2004 - 20 SEP 2010 4. TITLE AND SUBTITLE Pre-clinical and clinical evaluation of high resolution, mobile gamma camera and positron imaging devices...a compact and mobile gamma and positron imaging camera . This imaging device has several advantages over conventional systems: (1) greater

  3. Design Study of Linear Accelerator-Based Positron Re-Emission Microscopy

    NASA Astrophysics Data System (ADS)

    Ogawa, Hiroshi; Kinomura, Atsushi; Oshima, Nagayasu; Suzuki, Ryoichi; O'Rourke, Brian E.

    In order to shorten the acquisition time of positron re-emission microscopy (PRM), a linear accelerator (LINAC)-based PRM system has been studied. The beam focusing system was designed to obtain a high brightness positron beam on the PRM sample. The beam size at the sample was calculated to be 0.8mm (FWHM), and the positron intensity within the field of view of the PRM was more than one order of magnitude higher in comparison with the previous studies.

  4. Present and future experiments using bright low-energy positron beams

    NASA Astrophysics Data System (ADS)

    Hugenschmidt, Christoph

    2017-01-01

    Bright slow positron beams enable not only experiments with drastically reduced measurement time and improved signal-to-noise ratio but also the realization of novel experimental techniques. In solid state physics and materials science positron beams are usually applied for the depth dependent analysis of vacancy-like defects and their chemical surrounding using positron lifetime and (coincident) Doppler broadening spectroscopy. For surface studies, annihilation induced Auger-electron spectroscopy allows the analysis of the elemental composition in the topmost atomic layer, and the atomic positions at the surface can be determined by positron diffraction with outstanding accuracy. In fundamental research low-energy positron beams are used for the production of e.g. cold positronium or positronium negative ions. All the aforementioned experiments benefit from the high intensity of present positron beam facilities. In this paper, we scrutinize the technical constraints limiting the achievable positron intensity and the available kinetic energy at the sample position. Current efforts and future developments towards the generation of high intensity spin-polarized slow positron beams paving the way for new positron experiments are discussed.

  5. Comment on "Gamma-ray spectra from low-energy positron annihilation processes in molecules"

    NASA Astrophysics Data System (ADS)

    Green, D. G.; Gribakin, G. F.

    2017-03-01

    In the article by Ma et al. [Phys. Rev. A 94, 052709 (2016), 10.1103/PhysRevA.94.052709], γ -ray spectra for positron annihilation on molecules were calculated in the independent-particle approximation with the positron wave function set to unity. Based on comparisons with experimental data, they concluded that inner valence electrons play a dominant role in positron annihilation. These conclusions are incorrect and resulted from fallacious analysis that ignored the known effect of the positron wave function on the spectra.

  6. On the use of positrons to probe magnetic versus electrostatic turbulence

    SciTech Connect

    Stambaugh, R.D.

    1990-10-01

    Kwon, et al. have shown that runaway electron (positron) diffusion is produced by magnetic turbulence and unaffected by electrostatic turbulence. By measuring the diffusion coefficient of positrons at runaway energies (0.1-2 MeV) as a function of radius for two discrete positron energies, the radial correlation length W of the turbulence can be extracted. Then if the thermal electrons are in a weak turbulence regime, the thermal electron diffusion coefficient from magnetic fluctuations alone can be calculated and compared to values from other techniques. We propose to inject charged energetic positrons (100--2000 keV) in few msec bursts from radioactive sources by means of their curvature drift when trapped in toroidal field ripples. The energetic positrons will diffuse over 60--600 msec time scales. At any time the radial profile of the positrons can be sampled by injecting a small solid pellet. A fraction of all the positrons on a flux surface will annihilate in the pellet as it passes that flux surface. The time dependent 0.511 MeV {gamma}-ray signal then can be unfolded into the positron radial profile and the positron diffusion coefficient determined from the time evolution of those profiles. 8 refs.

  7. PROBING THE PULSAR ORIGIN OF THE ANOMALOUS POSITRON FRACTION WITH AMS-02 AND ATMOSPHERIC CHERENKOV TELESCOPES

    SciTech Connect

    Linden, Tim; Profumo, Stefano

    2013-07-20

    Recent observations by PAMELA, Fermi-LAT, and AMS-02 have conclusively indicated a rise in the cosmic-ray positron fraction above 10 GeV, a feature which is impossible to mimic under the paradigm of secondary positron production with self-consistent Galactic cosmic-ray propagation models. A leading explanation for the positron fraction rise is an additional source of electron-positron pairs, for example one or more mature, energetic, and relatively nearby pulsars. We point out that any one of two well-known nearby pulsars, Geminga and Monogem, can satisfactorily provide enough positrons to reproduce AMS-02 observations. A smoking-gun signature of this scenario is an anisotropy in the arrival direction of the cosmic-ray electrons and positrons, which may be detectable by existing, or future, telescopes. The predicted anisotropy level is, at present, consistent with limits from Fermi-LAT and AMS-02. We argue that the large collecting area of atmospheric Cherenkov telescopes (ACTs) makes them optimal tools for detecting such an anisotropy. Specifically, we show that much of the proton and {gamma}-ray background which affects measurements of the cosmic-ray electron-positron spectrum with ACTs may be controlled in the search for anisotropies. We conclude that observations using archival ACT data could already constrain or substantiate the pulsar origin of the positron anomaly, while upcoming instruments (such as the Cherenkov Telescope Array) will provide strong constraints on the source of the rising positron fraction.

  8. Admittance Test and Conceptual Study of a CW Positron Source for CEBAF

    SciTech Connect

    Golge, Serkan; Hyde, Charles E.; Freyberger, Arne

    2009-09-02

    A conceptual study of a Continuous Wave (CW) positron production is presented in this paper. The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLAB) operates with a CW electron beam with a well-defined emittance, time structure and energy spread. Positrons created via bremsstrahlung photons in a high-Z target emerge with a large emittance compared to incoming electron beam. An admittance study has been performed at CEBAF to estimate the maximum beam phase space area that can be transported in the LINAC and in the Arcs. A positron source is described utilizing the CEBAF injector electron beam, and directly injecting the positrons into the CEBAF LINAC.

  9. Positron bunching and electrostatic transport system for the production and emission of dense positronium clouds into vacuum

    NASA Astrophysics Data System (ADS)

    Aghion, S.; Amsler, C.; Ariga, A.; Ariga, T.; Belov, A. S.; Bonomi, G.; Bräunig, P.; Bremer, J.; Brusa, R. S.; Cabaret, L.; Caccia, M.; Caravita, R.; Castelli, F.; Cerchiari, G.; Chlouba, K.; Cialdi, S.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Dudarev, A.; Ereditato, A.; Evans, C.; Fesel, J.; Fontana, A.; Forslund, O. K.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Gninenko, S.; Guatieri, F.; Haider, S.; Holmestad, H.; Huse, T.; Jernelv, I. L.; Jordan, E.; Kaltenbacher, T.; Kellerbauer, A.; Kimura, M.; Koetting, T.; Krasnicky, D.; Lagomarsino, V.; Lebrun, P.; Lansonneur, P.; Lehner, S.; Liberadzka, J.; Malbrunot, C.; Mariazzi, S.; Marx, L.; Matveev, V.; Mazzotta, Z.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Pagano, D.; Penasa, L.; Petracek, V.; Pistillo, C.; Prelz, F.; Prevedelli, M.; Ravelli, L.; Rienäcker, B.; Røhne, O. M.; Rosenberger, S.; Rotondi, A.; Sacerdoti, M.; Sandaker, H.; Santoro, R.; Scampoli, P.; Sorrentino, F.; Spacek, M.; Storey, J.; Strojek, I. M.; Testera, G.; Tietje, I.; Vamosi, S.; Widmann, E.; Yzombard, P.; Zavatarelli, S.; Zmeskal, J.

    2015-11-01

    We describe a system designed to re-bunch positron pulses delivered by an accumulator supplied by a positron source and a Surko-trap. Positron pulses from the accumulator are magnetically guided in a 0.085 T field and are injected into a region free of magnetic fields through a μ -metal field terminator. Here positrons are temporally compressed, electrostatically guided and accelerated towards a porous silicon target for the production and emission of positronium into vacuum. Positrons are focused in a spot of less than 4 mm FWTM in bunches of ∼8 ns FWHM. Emission of positronium into the vacuum is shown by single shot positron annihilation lifetime spectroscopy.

  10. N-(/sup 11/C)-methyl-p-substituted phentermine analogs as potential brain blood flow agents for positron tomography

    SciTech Connect

    Kizuka, H.; Elmaleh, D.R.; Boudreaux, G.J.; Anderton, K.D.; Strauss, H.W.; Ackerman, R.H.; Brownell, G.L.

    1984-01-01

    The addition of a methyl group to the ..cap alpha..-position of amphetamine increases both the lipophilicity of the agent and its resistance to metabolism by monoamine oxidase. In addition, since tritium substituted phenteramine analog studies suggested that the p-halo phentermines had a greater concentration in the brain and prolonged retention time, the authors evaluated the biological behavior of positron labeled ..cap alpha..-methylamphetamine (phenteramine) in rats, dogs and monkeys. The N-(/sup 11/C) methyl analogs of p-chloro (I) and p-fluoro (II) phentermines were prepared by methylation of their primary amines using /sup 11/Ch/sub 3/I. Biodistribution studies in rats shows brain uptake is in the range of 1% dose/gr at 5 and 15 min for both agents. The activity in blood and eyes is low. Sequential images of the dogs' brain over 1 hour revealed a clearance of <15%. Images of the monkey brain were also obtained using a MGH positron camera PCR-I.

  11. Study of four-lepton final states in electron-positron interactions at 29 GeV

    SciTech Connect

    Petradza, A.

    1989-08-01

    This thesis presents a study of electron-positron scattering to four light leptons. The motivations behind it are twofold. Firstly, the study is a test of the theory of electron-positron interactions to 4th order in the fine structure constant {alpha}. A deviation from the theory could indicate the existence of a heavy new particle. Secondly, a measurement of these processes may prove useful in the understanding of other QED-type reactions. The method for simulating the four-lepton processes by the Monte Carlo event generator of Berends, Daverveldt and Kleiss is described. Theoretical predictions are compared to data from the Mark II and HRS experiments at the PEP storage ring. The observed events consist of four leptons at large angles. Data for all three e{sup +}e{sup -}e{sup +}e{sup -}, e{sup +}e{sup -}{mu}{sup +}{mu}{sup -} and {mu}{sup +}{mu}{sup -}{mu}{sup +}{mu}{sup -} processes are well described by the QED Monte Carlo calculation. The various kinematical distributions are in good agreement with QED to order {alpha}{sup 4}. 18 refs., 64 figs., 19 tabs.

  12. Positron emission tomography for use in microdosing studies.

    PubMed

    Wagner, Claudia Christina; Müller, Markus; Lappin, Graham; Langer, Oliver

    2008-01-01

    Positron emission tomography (PET) imaging using microdoses of radiolabeled drug tracers is gaining increasing acceptance in modern clinical drug development. This approach is unique in that it allows for direct quantitative assessment of drug concentrations in the tissues targeted for treatment, thereby bridging the gap between pharmacokinetics and pharmacodynamics. Current applications of PET in anticancer, anti-infective and central nervous system drug research are reviewed herein. Situated at the interface of preclinical and clinical drug testing, PET microdosing is a powerful and highly innovative tool for pharmaceutical development.

  13. Morphology of Thermoset Polyimides by Positron Annihilation Spectroscopy

    NASA Technical Reports Server (NTRS)

    Ranganathaiah, C.; Pater, R. H.; Sprinkle, D. R.; Baugher, A. H.; Eftekhari, A.; Singh, J. J.

    1994-01-01

    Thermoset polyimides have great potential for successfully meeting tough stress and temperature challenges in the advanced aircraft development program. However, studies of structure/property relationships in these materials have not been very successful so far. Positron annihilation spectroscopy has been used to investigate free volumes and associated parameters. It has been noted that the free volume correlates well with the molecular weight, cross-link density and thermal coefficient of expansion of these materials. Currently no other techniques are available for direct measurement of these parameters. Experimental results and their interpretations will be discussed.

  14. Fatigue damage in superalloys determined using Doppler broadening positron annihilation

    NASA Technical Reports Server (NTRS)

    Hoeckelman, Donald; Leighly, H. P., Jr.

    1990-01-01

    Axial fatigue specimens of three superalloys, Inconel 718, Incoloy 903 and Haynes 188, were machined from solution-heat-treated material and artificially aged. They were subjected to cyclic loading for a selected number of cycles after which the S parameter was determined using Doppler broadening positron annihilation. Initially, the S parameter decreased, followed by a large increase and a subsequent decline leading to fracture. This has been interpreted as the removal of residual vacancies, the introduction of new defects by cyclic loading, and, finally, a clustering of the defects as microcracks which grow to cause failure.

  15. Direct conversion semiconductor detectors in positron emission tomography

    NASA Astrophysics Data System (ADS)

    Cates, Joshua W.; Gu, Yi; Levin, Craig S.

    2015-05-01

    Semiconductor detectors are playing an increasing role in ongoing research to improve image resolution, contrast, and quantitative accuracy in preclinical applications of positron emission tomography (PET). These detectors serve as a medium for direct detection of annihilation photons. Early clinical translation of this technology has shown improvements in image quality and tumor delineation for head and neck cancers, relative to conventional scintillator-based systems. After a brief outline of the basics of PET imaging and the physical detection mechanisms for semiconductor detectors, an overview of ongoing detector development work is presented. The capabilities of semiconductor-based PET systems and the current state of these devices are discussed.

  16. [Positron emission tomography: diagnostic imaging on a molecular level].

    PubMed

    Allemann, K; Wyss, M; Wergin, M; Bley, C Rohrer; Ametamay, S; Bruehlmeier, M; Kaser-Hotz, B

    2004-08-01

    In human medicine positron emission tomography (PET) is a modern diagnostic imaging method. In the present paper we outline the physical principles of PET and give an overview over the main clinic fields where PET is being used, such as neurology, cardiology and oncology. Moreover, we present a current project in veterinary medicine (in collaboration with the Paul Scherrer Institute and the University Hospital Zurich), where a hypoxia tracer is applied to dogs and cats suffering from spontaneous tumors. Finally new developments in the field of PET were discussed.

  17. Low-energy scattering of electrons and positrons in liquids

    NASA Technical Reports Server (NTRS)

    Schrader, D. M.

    1990-01-01

    The scattering of low energy electrons and positrons is described for the liquid phase and compared and contrasted with that for the gas phase. Similarities as well as differences are noted. The loci of scattering sites, called spurs in the liquid phase, are considered in detail. In particular, their temporal and spatial evolution is considered from the point of view of scattering. Two emphases are made: one upon the stochastic calculation of the distribution of distances required for slowing down to thermal velocities, and the other upon the calculation of cross sections for energy loss by means of quantum mechanics.

  18. Positron annihilation study of cavities in black Au films

    NASA Astrophysics Data System (ADS)

    Melikhova, O.; Čížek, J.; Hruška, P.; Vlček, M.; Procházka, I.; Anwand, W.; Novotný, M.; Bulíř, J.

    2017-01-01

    Defects in a black Au film were studied using variable energy positron annihilation spectroscopy. Black Au films exhibit porous morphology similar to cauliflower. This type of structure enhances the optical absorption due to a multiple reflections in the micro-cavities. A nanostructured black Au film was compared with conventional smooth Au films with high reflectivity. The black Au film exhibited a remarkably enhanced S-parameter in sub-surface region. This is caused by a narrow para-Positronium contribution to the annihilation peak.

  19. Positron scattering from hydrogen atom with screened Coulomb potentials

    SciTech Connect

    Ghoshal, Arijit; Nayek, Sujay; Kamali, M. Z. M.; Ratnavelu, K.

    2014-03-05

    Elastic positron-hydrogen collisions with screened Coulomb potentials have been investigated using a second-order distorted wave Born approximation in the momentum space. Two types of potentials have been considered, namely, static screened Coulomb potential and exponential cosine-screened Coulomb potential. Using a simple variationally determined hydrogenic wave function it has been possible to obtain the scattering amplitude in a closed form. A detailed study has been made on the differential and total cross sections in the energy range 20–300 eV.

  20. AMS results on positrons and antiprotons in cosmic rays

    NASA Astrophysics Data System (ADS)

    Kounine, Andrei; AMS Collaboration

    2017-01-01

    AMS-02 is a particle physics detector collecting data on the International Space Station since May 2011. Precision measurements of charged cosmic ray particles have been performed by AMS using a data sample of 85 billion cosmic ray events collected during the first five years of operations on the Station. The latest AMS results on the fluxes and flux ratios of the cosmic ray particles are presented with the emphasis on the measurements of positrons and antiprotons. They show unique features that require accurate theoretical interpretation as to their origin, be it from dark matter collisions or new astrophysical sources. On behalf of AMS.

  1. Electron-positron pair equilibrium in strongly magnetized plasmas

    SciTech Connect

    Harding, A.K.

    1984-11-01

    Steady states of thermal electron-positron pair plasmas at mildly relativistic temperatures and in strong magnetic fields are investigated. The pair density in steady-state equilibrium, where pair production balances annihilation, is found as a function of temperature, magnetic field strength and source size, by a numerical calculation which includes pair production attenuation and Compton scattering of the photons. It is found that there is a maximum pair density for each value of temperature and field strength, and also a source size above which optically thin equilibrium states do not exist. (ESA)

  2. Positron lifetime measurements in chiral nematic liquid crystals

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Eftekhari, Abe; Parmar, Devendra S.

    1991-01-01

    Positron lifetimes in the isotropic phases of chiral nematic liquid crystal formulations and their mixtures up to the racemic level were measured. The lifetime spectra for all liquid crystal systems were analyzed into three components. Although the individual spectra in the left- and right-handed components are identical, their racemic mixtures exhibit much larger orthopositronium lifetimes; these larger lifetimes indicate the presence of larger microvoids. This result is consistent with the reportedly higher thermodynamic stability and color play range in the racemic mixtures of chiral nematic liquid crystals.

  3. Positron Emission Tomography (PET) for benign and malignant disease

    PubMed Central

    Visioni, Anthony; Kim, Julian

    2011-01-01

    Synopsis Functional imaging using radiolabeled probes which specifically bind and accumulate in target tissues has improved the sensitivity and specificity of conventional imaging. Positron Emission Tomography using modified glucose probes (FDG-PET) has demonstrated improved diagnostic accuracy in differentiating benign from malignant lesions in the setting of solitary pulmonary nodules. In addition, FDG-PET has become a useful modality in pre-operative staging of patients with lung cancer and is being tested with many other malignancies for its ability to change patient management. This article provides an overview of the current status of FDG-PET and presents the challenges of moving towards routine use. PMID:21184913

  4. Study of Chemical Carcinogens by Positron Annihilation Lifetime Spectroscopy

    NASA Astrophysics Data System (ADS)

    Pivtsaev, A. A.; Razov, V. I.; Karasev, A. O.

    2013-11-01

    We have used positron annihilation lifetime spectroscopy to study the carcinogens C21H20BrN3, C4H7Cl2O4P, CCl4, CHCl3, AlF3, C8H12N4O, C6H4Cl2 and the non-carcinogens H2O, AlCl3, CH2Cl2, C2H6OS. We have established a correlation between the annihilation characteristics of the studied compounds and their degree of carcinogenicity.

  5. Optical distortions in electron/positron storage rings

    SciTech Connect

    Brown, K.L.; Donald, M.; Servranckx, R.

    1983-01-01

    We have studied the optical distortions in the PEP electron/positron storage ring for various optical configurations using the computer programs DIMAT, HARMON, PATRICIA, and TURTLE. The results are shown graphically by tracing several thousand trajectories from one interaction region to the next using TURTLE and by tracing a few selected rays several hundred turns using the programs DIMAT and PATRICIA. The results show an interesting correlation between the calculated optical cleanliness of a particular lattice configuration and the observed operating characteristics of the machine.

  6. Role of positron emission tomography/computed tomography in dementia.

    PubMed

    Hinds, Sidney R; Stocker, Derek J; Bradley, Yong C

    2013-09-01

    This article provides a clinically based review of positron emission tomography (PET) imaging for dementia. Significant advances in nuclear medicine and molecular imaging techniques have improved the understanding of the genetic and molecular processes that define neurodegenerative dementia diseases. Metabolic imaging remains constant in its ability to document neuronal loss and lost function. Amyloid-β radiotracers are useful in documenting amyloid deposition, differentiating origins of dementia and possibly predicting disease progression. These radiotracers may be useful in diagnosis-specific treatment. PET radiotracers have increased sensitivity and specificity to complement clinical presentation and other adjunct testing in the evaluation of dementia.

  7. Positron emission tomography in the evaluation of subdural hematomas

    SciTech Connect

    Ericson, K.; Bergstroem, M.; Eriksson, L.

    1980-12-01

    Fifteen patients with 21 subdural effusions were investigated both with transmission computer assisted tomography (CAT) and positron emission tomography (PET). The tracer in the emission studies was /sup 68/Ga-EDTA. Twelve lesions were visualized both with CAT and PET. Five lesions that were negative or doubtful on CAT were visualized with PET, whereas four lesions negative or doubtful on PET were demonstrated by CAT. The two methods complement each other due to the fact that they are based on different mechanisms: CAT mainly on attenuation of the fluid collection. PET on isotope accumulation, particularly in the hematoma membranes.

  8. Evaluation of the reactor pressure vessel steels by positron annihilation

    NASA Astrophysics Data System (ADS)

    Slugeň, V.; Hein, H.; Sojak, S.; Simeg Veterníková, J.; Petriska, M.; Sabelová, V.; Pavúk, M.; Hinca, R.; Stacho, M.

    2013-11-01

    This paper presents a comparison of commercially used German and Russian reactor pressure vessel steels from the positron annihilation spectroscopy (PAS) point of view, having in mind knowledge obtained also from other techniques from the last decades. The second generation of Russian RPV steels seems to be fully comparable with German steels and their quality allows prolongation of NPP operating lifetime over projected 40 years. The embrittlement of CrMoV steels is relatively low due to effect of higher temperature which implies partial in situ annealing of primary microstructural point defects and therefore delays the degradation processes caused by neutron irradiation.

  9. NLC Polarized Positron Photon Beam Target Thermal Structural Modeling

    SciTech Connect

    Stein, W; Sheppard, J C

    2002-06-11

    The NLC polarized positron photon beam target is a 0.4 radiation length thick titanium target. Energy deposition from one pulse occurs over 266 nano-seconds and results in heating of the target and pressure pulses straining the material. The 22.1 MeV photon beam has a spot size of 0.75 mm and results in a maximum temperature jump of 233 C. Stresses are induced in the material from thermal expansion of the hotter material. Peak effective stresses reach 19 Ksi (1.34 x 10{sup 8} Pa), which is lower than the yield strength of a titanium alloy by a factor of six.

  10. The McMaster positron emission tomograph: Design and evaluation

    NASA Astrophysics Data System (ADS)

    Nahmias, Claude

    1984-03-01

    The McMaster positron emission tomograph is an instrument designed for the high resolution, cross sectional study of the human brain. The detector head comprises 160 bismuth germanate crystals, each coupled to a 12.7 mm photomultiplier tube, closely packed on a ring, 53.5 cm in diameter. The tomographic slices examined are either 10 or 20 mm thick. The spatial resolution is 8 mm (fwhm) in the stationary mode. The sensitivity is 16 000 cps/μCi/cc for a 10 mm slice. The instrument has been in clinical use for the past 18 months.

  11. Evidence for regional catecholamine uptake and storage sites in the transplanted human heart by positron emission tomography

    SciTech Connect

    Schwaiger, M.; Hutchins, G.D.; Kalff, V.; Rosenspire, K.; Haka, M.S.; Mallette, S.; Deeb, G.M.; Abrams, G.D.; Wieland, D. )

    1991-05-01

    Positron emission tomography in combination with the newly introduced catecholamine analogue ({sup 11}C)hydroxyephedrine (({sup 11}C)HED) enables the noninvasive delineation of sympathetic nerve terminals of the heart. To address the ongoing controversy over possible reinnervation of the human transplant, 5 healthy control subjects and 11 patients were studied after cardiac transplant by this imaging approach. Regional ({sup 11}C)HED retention was compared to regional blood flow as assessed by rubidium-82. Transplant patients were divided into two groups. Group I had recent (less than 1 yr, 4.4 +/- 2.3 mo) surgery, while group II patients underwent cardiac transplantation more than 2 yr before imaging (3.5 +/- 1.3 yr). ({sup 11}C)HED retention paralleled blood flow in normals, but was homogeneously reduced in group I. In contrast, group II patients revealed heterogeneous ({sup 11}C)HED retention, with increased uptake in the proximal anterior and septal wall. Quantitative evaluation of ({sup 11}C)HED retention revealed a 70% reduction in group I and 59% reduction in group II patients (P less than 0.001). In group II patients, ({sup 11}C)HED retention reached 60% of normal in the proximal anterior wall. These data suggest the presence of neuronal tissue in the transplanted human heart, which may reflect regional sympathetic reinnervation.

  12. Synthesis, structure-affinity relationships, and radiolabeling of selective high-affinity 5-HT4 receptor ligands as prospective imaging probes for positron emission tomography.

    PubMed

    Xu, Rong; Hong, Jinsoo; Morse, Cheryl L; Pike, Victor W

    2010-10-14

    In a search for high-affinity receptor ligands that might serve for development as radioligands for the imaging of brain 5-HT(4) receptors in vivo with positron emission tomography (PET), structural modifications were made to the high-affinity 5-HT(4) antagonist (1-butylpiperidin-4-yl)methyl 8-amino-7-iodo-2,3-dihydrobenzo[b][1,4]dioxine-5-carboxylate (1, SB 207710). These modifications were made mainly on the aryl side of the ester bond to permit possible rapid labeling of the carboxylic acid component with a positron emitter, either carbon-11 (t(1/2) = 20.4 min) or fluorine-18 (t(1/2) = 109.7 min), and included (i) replacement of the iodine atom with a small substituent such as nitrile, methyl, or fluoro, (ii) methylation of the 8-amino group, (iii) opening of the dioxan ring, and (iv) alteration of the length of the N-alkyl goup. High-affinity ligands were discovered for recombinant human 5-HT(4) receptors with amenability to labeling with a positron emitter and potential for development as imaging probes. The ring-opened radioligand, (([methoxy-(11)C]1-butylpiperidin-4-yl)methyl 4-amino-3-methoxybenzoate; [(11)C]13), showed an especially favorable array of properties for future evaluation as a PET radioligand for brain 5-HT(4) receptors.

  13. Positron accumulation effect in particles embedded in a low-density matrix

    SciTech Connect

    Dryzek, Jerzy; Siemek, Krzysztof

    2015-02-07

    Systematic studies of the so-called positron accumulation effect for samples with particles embedded in a matrix are reported. This effect is related to energetic positrons which penetrate inhomogeneous medium. Due to differences in the linear absorption coefficient, different amounts of positrons are accumulated and annihilate in the identical volume of both materials. Positron lifetime spectroscopy and Doppler broadening of the annihilation line using Na-22 positrons were applied to the studies of the epoxy resin samples with embedded micro-sized particles of transition metals, i.e., Ni, Sn, Mo, W, and nonmetal particles, i.e., Si and NaF. The significant difference between the determined fraction of positrons annihilating in the particles and the particle volume fraction indicates the positron accumulation effect. The simple phenomenological model and Monte Carlo simulations are able to describe the main features of the obtained dependencies. The aluminum alloy with embedded Sn nanoparticles is also considered for demonstration differences between the accumulation and another related effect, i.e., the positron affinity.

  14. Positron Annihilation Spectroscopy of High Performance Polymer Films under CO2 Pressure

    SciTech Connect

    C.A. Quarles; John R. Klaehn; Eric S. Peterson; Jagoda M. Urban-Klaehn

    2010-08-01

    Positron annihilation Lifetime and Doppler broadening measurements are reported for six polymer films as a function of carbon dioxide absolute pressure ranging from 0 to 45 psi. Since the polymer films were thin and did not absorb all positrons, corrections were made in the lifetime analysis for the absorption of positrons in the positron source and sample holder using the Monte Carlo transport code MCNP. Different polymers are found to behave differently. Some polymers studied form positronium and some, such as the polyimide structures, do not. For those samples that form positronium an interpretation in terms of free volume is possible; for those that don’t form positronium, further work is needed to determine how best to describe the behavior in terms of the bulk positron annihilation parameters. Some polymers exhibit changes in positron lifetime and intensity under CO2 pressure which may be described by the Henry or Langmuir sorption models, while the positron response of other polymers is rather insensitive to the CO2 pressure. The results demonstrate the usefulness of positron annihilation spectroscopy in investigating the sorption of CO2 into various polymers at pressures up to about 3 atm.

  15. Positron Annihilation Spectroscopy Of High Performance Polymer Films Under CO{sub 2} Pressure

    SciTech Connect

    Quarles, C. A.; Klaehn, John R.; Peterson, Eric S.; Urban-Klaehn, Jagoda M.

    2011-06-01

    Positron annihilation Lifetime and Doppler broadening measurements are reported for six polymer films as a function of carbon dioxide (CO{sub 2}) absolute pressure ranging from 0 to 45 psi. Since the polymer films were thin and did not absorb all positrons, corrections were made in the lifetime analysis for the absorption of positrons in the positron source and sample holder using the Monte Carlo transport code MCNP. The studied polymers are found to behave differently from each other. Some polymers form positronium and others, such as the polyimide structures, do not. For those polymers that form positronium an interpretation in terms of free volume is possible; for those that don't form positronium, further work is needed to determine how best to describe the behavior in terms of the bulk positron annihilation parameters. A few of the studied polymers exhibit changes in positron lifetime and intensity under CO{sub 2} pressure which may be described by the Henry or Langmuir sorption models, while the positron response of other polymers is rather insensitive to the CO{sub 2} pressure. The results demonstrate the usefulness of positron annihilation spectroscopy in investigating the sorption of CO{sub 2} into various polymers at pressures up to about 3 atm (45psi).

  16. Positron accumulation effect in particles embedded in a low-density matrix

    NASA Astrophysics Data System (ADS)

    Dryzek, Jerzy; Siemek, Krzysztof

    2015-02-01

    Systematic studies of the so-called positron accumulation effect for samples with particles embedded in a matrix are reported. This effect is related to energetic positrons which penetrate inhomogeneous medium. Due to differences in the linear absorption coefficient, different amounts of positrons are accumulated and annihilate in the identical volume of both materials. Positron lifetime spectroscopy and Doppler broadening of the annihilation line using Na-22 positrons were applied to the studies of the epoxy resin samples with embedded micro-sized particles of transition metals, i.e., Ni, Sn, Mo, W, and nonmetal particles, i.e., Si and NaF. The significant difference between the determined fraction of positrons annihilating in the particles and the particle volume fraction indicates the positron accumulation effect. The simple phenomenological model and Monte Carlo simulations are able to describe the main features of the obtained dependencies. The aluminum alloy with embedded Sn nanoparticles is also considered for demonstration differences between the accumulation and another related effect, i.e., the positron affinity.

  17. The Distribution of Galactic 511 keV Positron Annihilation Radiation

    DTIC Science & Technology

    1994-01-01

    and 44Sc, this positron production rate implies a limit to the present rate of Galactic iron nucleosynthesis of 0:7 M per 100 years (see Ramaty...constraints on the positron production rate for the disk and spheroidal components, and on the present rate of Galactic nucleosynthesis of +-unstable

  18. Design and performance of the pulsed positron beam at Chalmers University of Technology

    NASA Astrophysics Data System (ADS)

    Mileshina, L.; Nordlund, A.

    2009-09-01

    A slow monoenergetic pulsed positron beam at Chalmers University of Technology has been built. The system consists mainly of chopper, buncher and accelerator. The achieved positron energy range is in range between 230 eV and 15 keV. The FWHM of the beam resolution function is around 700 ps. The beam intensity is around 103 cps.

  19. Frederic Joliot, Irene Curie and the Early History of the Positron (1932-33)

    ERIC Educational Resources Information Center

    Leone, Matteo; Robotti, Nadia

    2010-01-01

    As is well known, the positron was discovered in August 1932 by Carl Anderson while studying cloud chamber tracks left by cosmic rays. Far less known is the fact that a few months before Anderson's discovery, in April 1932, Frederic Joliot and Irene Curie had missed an opportunity to discover the positron during a nuclear physics experiment. One…

  20. Operating instructions for ORELA (Oak Ridge Electron Linear Accelerator) positron beam line

    SciTech Connect

    Donohue, D.L.; Hulett, L.D. Jr.; Lewis, T.A.

    1990-11-01

    This report will contain details of the construction and operation of the positron beam line. Special procedures which are performed on a less frequent basis will also be described. Appendices will contain operating instructions for experiments which make use of the positron beam and are connected to the beam line. Finally, a review of safety-related considerations will be presented.

  1. Stable confinement of electron plasma and initial results on positron injection in RT-1

    NASA Astrophysics Data System (ADS)

    Saitoh, H.; Yoshida, Z.; Morikawa, J.; Yano, Y.; Kasaoka, N.; Sakamoto, W.; Nogami, T.

    2013-03-01

    The Ring Trap 1 (RT-1) device is a dipole field configuration generated by a levitated superconducting magnet. It offers very interesting opportunities for research on the fundamental properties on non-neutral plasmas, such as self-organization of charged particles in the strongly positive and negative charged particles on magnetic surfaces. When strong positron sources will be available in the future, the dipole field configuration will be potentially applicable to the formation of an electron-positron plasma. We have realized stable, long trap of toroidal pure electron plasma in RT-1; Magnetic levitation of the superconducting magnet resulted in more than 300s of confinement for electron plasma of ˜ 1011 m-3. Aiming for the confinement of positrons as a next step, we started a positron injection experiment. For the formation of positron plasma in the closed magnetic surfaces, one of the key issues to be solved is the efficient injection method of positron across closed magnetic surfaces. In contrast to linear configurations, toroidal configurations have the advantage that they are capable of trapping high energy positrons in the dipole field configuration and consider the possibility of direct trapping of positrons emitted from a 22Na source.

  2. Analytical positron range modelling in heterogeneous media for PET Monte Carlo simulation.

    PubMed

    Lehnert, Wencke; Gregoire, Marie-Claude; Reilhac, Anthonin; Meikle, Steven R

    2011-06-07

    Monte Carlo simulation codes that model positron interactions along their tortuous path are expected to be accurate but are usually slow. A simpler and potentially faster approach is to model positron range from analytical annihilation density distributions. The aims of this paper were to efficiently implement and validate such a method, with the addition of medium heterogeneity representing a further challenge. The analytical positron range model was evaluated by comparing annihilation density distributions with those produced by the Monte Carlo simulator GATE and by quantitatively analysing the final reconstructed images of Monte Carlo simulated data. In addition, the influence of positronium formation on positron range and hence on the performance of Monte Carlo simulation was investigated. The results demonstrate that 1D annihilation density distributions for different isotope-media combinations can be fitted with Gaussian functions and hence be described by simple look-up-tables of fitting coefficients. Together with the method developed for simulating positron range in heterogeneous media, this allows for efficient modelling of positron range in Monte Carlo simulation. The level of agreement of the analytical model with GATE depends somewhat on the simulated scanner and the particular research task, but appears to be suitable for lower energy positron emitters, such as (18)F or (11)C. No reliable conclusion about the influence of positronium formation on positron range and simulation accuracy could be drawn.

  3. Detection of Ga vacancies in electron irradiated GaAs by positrons

    SciTech Connect

    Hautojaervi, P.; Moser, P.; Stucky, M.; Corbel, C.; Plazaola, F.

    1986-03-24

    Positron lifetime measurements have been used to study the recovery of electron irradiated GaAs between 77 and 800 K. Below room temperature positrons are trapped by vacancies in Ga sublattices. The Ga vacancies recover between 200 and 350 K.

  4. Positron emission tomography: physics, instrumentation, and image analysis.

    PubMed

    Porenta, G

    1994-01-01

    Positron emission tomography (PET) is a noninvasive diagnostic technique that permits reconstruction of cross-sectional images of the human body which depict the biodistribution of PET tracer substances. A large variety of physiological PET tracers, mostly based on isotopes of carbon, nitrogen, oxygen, and fluorine is available and allows the in vivo investigation of organ perfusion, metabolic pathways and biomolecular processes in normal and diseased states. PET cameras utilize the physical characteristics of positron decay to derive quantitative measurements of tracer concentrations, a capability that has so far been elusive for conventional SPECT (single photon emission computed tomography) imaging techniques. Due to the short half lives of most PET isotopes, an on-site cyclotron and a radiochemistry unit are necessary to provide an adequate supply of PET tracers. While operating a PET center in the past was a complex procedure restricted to few academic centers with ample resources, PET technology has rapidly advanced in recent years and has entered the commercial nuclear medicine market. To date, the availability of compact cyclotrons with remote computer control, automated synthesis units for PET radiochemistry, high-performance PET cameras, and user-friendly analysis workstations permits installation of a clinical PET center within most nuclear medicine facilities. This review provides simple descriptions of important aspects concerning physics, instrumentation, and image analysis in PET imaging which should be understood by medical personnel involved in the clinical operation of a PET imaging center.

  5. Photon shielding for a positron emission tomography suite.

    PubMed

    Courtney, J C; Mendez, P; Hidalgo-Salvatierra, O; Bujenovic, S

    2001-08-01

    This paper provides information on the effects of distance and attenuation in lead sheet and gypsum board of the 0.511 MeV photon produced by positron annihilation. Exposure rates are projected external to an adult injected with 185 MBq (5 mCi) of 18F in a fluorodeoxyglucose solution and for the same activity in a small unshielded container. These data have been applied to estimate the shielding requirements for the Positron Emission Tomography (PET) suite operated by the Nuclear Medicine Department of Our Lady of the Lake Regional Medical Center. To assure that exposures are as low as reasonably achievable, lead was added to the walls of the room where the 18F is stored, handled, and injected into the patients. The PET scanner is installed in a room that formerly contained a Computerized Axial Tomography scanner; the existing 1.6 mm of lead sheet was left in place even though it is not required for personnel protection. During the initial phase of operation, a shield test program was conducted to estimate annual exposures to personnel inside and outside the suite. Projection of measured rates over a year of operation demonstrate that whole body doses are well below regulatory limits.

  6. Synthesis and biological studies of positron-emitting radiopharmaceuticals

    SciTech Connect

    Dischino, D.D.

    1983-01-01

    The development and clinical evaluation of two-positron emitting radiopharmaceuticals designed to image myelin in humans is reported. Carbon-11-labeled benzyl methyl ether was synthesized by the reaction of carbon-11-labeled methanol and benzyl chloride in dimethyl sulfoxide containing powdered potassium hydroxide in a radiochemical yield of 43% and a synthesis and purification time of 40 minutes. Carbon-11-labeled diphenylmethanol was synthesized by the reaction of carbon-11-labeled carbon dioxide and phenyllithium followed by the reduction of the carbon-11-labeled intermediate to diphenylmethanol via lithium aluminum hydride in a radiochemical yield of 71% and a synthesis and purification time of 38 minutes. Carbon-11-labeled benzyl methyl ether and diphenylmethanol were each evaluated as myelin imaging agents in three patients with multiple sclerosis via positron-emission tomography. In two out of three patients studied with carbon-11-labeled benzyl methyl ether, the distribution of activity in the brain was not consistent with local lipid content. A new synthesis of carbon-11-labeled-DL-phenylalanine labeled in the benzylic position and the synthesis of fluorine-18-labeled 1-(2-nitro-1-imidazolyl)-3-fluoro-2-propanol, a potential in vivo marker of hypoxic tissue, are reported.

  7. Positron lifetime spectroscopy for investigation of thin polymer coatings

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Sprinkle, Danny R.; Eftekhari, Abe

    1993-01-01

    In the aerospace industry, applications for polymer coatings are increasing. They are now used for thermal control on aerospace structures and for protective insulating layers on optical and microelectronic components. However, the effectiveness of polymer coatings depends strongly on their microstructure and adhesion to the substrates. Currently, no technique exists to adequately monitor the quality of these coatings. We have adapted positron lifetime spectroscopy to investigate the quality of thin coatings. Results of measurements on thin (25-micron) polyurethane coatings on aluminum and steel substrates have been compared with measurements on thicker (0.2-cm) self-standing polyurethane discs. In all cases, we find positron lifetime groups centered around 560 psec, which corresponds to the presence of 0.9-A(exp 3) free-volume cells. However, the number of these free-volume cells in thin coatings is larger than in thick discs. This suggests that some of these cells may be located in the interfacial regions between the coatings and the substrates. These results and their structural implications are discussed in this report.

  8. Inelastic Collisions of Positrons with Beryllium and Magnesium Ions

    NASA Astrophysics Data System (ADS)

    El-Bakry, Salah-Yaseen

    The collision of positrons with beryllium and magnesium positive ions is treated for the first time as a three-channel problem with the assumption that the elastic, ground-positronium and excited-positronium formation channels are open. A one-valence-electron model for the targets, based on the Clementi-Roetti Slater basis functions, as well as an improved coupled-static approach allowing for the polarization of the excited positronium, are used for calculating the partial cross-sections of eight partial waves (corresponding to 0≤ℓ≤7, where ℓ is the total angular momentum of the scattering problem considered). The calculations are carried out, in each case, at 19 values of the incident energy lying above the excited positronium formation threshold (i.e. above 16.42 eV in e+-Be+ scattering and above 13.02 eV in e+-Mg+ scattering). The total elastic cross-sections of e+-Mg+ scattering show a peak around the ionization threshold of Mg+ (at 14.723 eV) but for e+-Be+ scattering, display a peak at 90 eV (remember that the ionization threshold of Be+ is 18.2 eV). Although the resulting total collisional positronium formation cross-sections are smaller than the elastic ones, their relatively large values should draw the attention of experimental and theoretical physicists to the field of positron-ion collisions.

  9. Gravitational mass of positron from LEP synchrotron losses

    NASA Astrophysics Data System (ADS)

    Kalaydzhyan, Tigran

    2016-07-01

    General relativity(GR) is the current description of gravity in modern physics. One of the cornerstones of GR, as well as Newton’s theory of gravity, is the weak equivalence principle (WEP), stating that the trajectory of a freely falling test body is independent of its internal structure and composition. WEP is known to be valid for the normal matter with a high precision. However, due to the rarity of antimatter and weakness of the gravitational forces, the WEP has never been confirmed for antimatter. The current direct bounds on the ratio between the gravitational and inertial masses of the antihydrogen do not rule out a repulsive nature for the antimatter gravity. Here we establish an indirect bound of 0.13% on the difference between the gravitational and inertial masses of the positron (antielectron) from the analysis of synchrotron losses at the Large Electron-Positron collider (LEP). This serves as a confirmation of the conventional gravitational properties of antimatter without common assumptions such as, e.g., coupling of gravity to virtual particles, dynamics of distant astrophysical sources and the nature of absolute gravitational potentials.

  10. HEAO 3 measurements of the atmospheric positron annihilation line

    SciTech Connect

    Mahoney, W.A.; Ling, J.C.; Jacobson, A.S.

    1981-12-01

    All spectra measured with the High Energy resolution Gamma-Ray Spectroscopy Experiment (HEAO C-1) on the third High Energy Astronomy Observatory (HEAO 3) contain a strong line at 511 keV resulting from positron annihilation. This line originates in the instrument itself, the earth's atmosphere, and cosmic sources, possibly including the diffuse cosmic background. In order to understand the emission from cosmic sources, the atmospheric positron annihilation line emission has been determined as a function of geomagnetic latitude and zenith angle. Although the intensity of the line increases with increasing latitude, it was found that variations with zenith angle can be satisfactorily explained only if the atmospheric emission exhibits significant limb darkening. The atmospheric line has an energy of 511.07 +- 0.10 keV and a net width of 2.29 +- 0.30 keV FWHM. Characteristics of the instrument background have allowed an upper limit of 9.4 x 10/sup -3/ photons/cm/sup 2/-sec-sr to be placed on any narrow (< or approx. =3 keV) diffuse cosmic emission at 511 keV.

  11. Positron Emission Tomography Application to Drug Development and Research

    NASA Astrophysics Data System (ADS)

    Salvadori, Piero A.

    The research for the identification and development of new drugs represents a very complex process implying long times and massive investments. This process was not able to parallel the rate of discoveries made in the field of genomic and molecular biology and a gap created between demand of new drugs and the ability of pharmaceutical companies to select good candidates. Positron Emission Tomography, among the different Molecular Imaging modalities, could represent a new tool for the early assessment and screening of new drug candidates and, due to its physical performances and the characteristics of positron-labeled tracers, gain the role of "Biomarker" accepted by the Companies and the Regulatory Bodies of Drug Agencies. To fulfil this task PET has to exploit all of its special features such as data absolute quantification and modelling, high spatial resolution and dynamic imaging. Relevant efforts need to be directed to the careful design and validation of experimental protocols with the main goal of achieving consistency in multi- centric trials.

  12. Progress Towards a Microtrap Array for Positron Storage

    NASA Astrophysics Data System (ADS)

    Narimannezhad, Alireza; Weber, Marc H.; Jennings, Joshah; Minnal, Chandrasekar; Lynn, Kelvin G.

    2014-10-01

    The storage of positrons has been a key for antimatter research and applications. One important goal is the attempt to reach higher densities of confined antimatter particles. Progress in this area is explored through a novel microtrap array with large length to radius aspect ratios and radii of the order of tens of microns. The proposed design consists of microtraps with substantially lower barrier potentials than conventional Penning-Malmberg traps arranged in parallel within a single magnet. Simulations showed positron plasma with 1E10 cm-3 density evolves toward a rigid-rotation phase in each microtrap while 10 V barriers confined the plasma axially. A trap of 4 cm length including more than 20,000 microtubes with 50 micron radii was fabricated and tested. Experiments conducted with electrons in a test structure addressing each microtube with a narrow beam will be described. This will explore the basic physics of the microtraps. Observed results were promising and they open a new avenue for manipulating high-density non-neutral plasmas. This work was supported by the Army Research Laboratory under Contract W9113M-09-C-0075, and the Office of Naval Research under Award #N00014-10-1-0543.

  13. Iodine-124: a promising positron emitter for organic PET chemistry.

    PubMed

    Koehler, Lena; Gagnon, Katherine; McQuarrie, Steve; Wuest, Frank

    2010-04-13

    The use of radiopharmaceuticals for molecular imaging of biochemical and physiological processes in vivo has evolved into an important diagnostic tool in modern nuclear medicine and medical research. Positron emission tomography (PET) is currently the most sophisticated molecular imaging methodology, mainly due to the unrivalled high sensitivity which allows for the studying of biochemistry in vivo on the molecular level. The most frequently used radionuclides for PET have relatively short half-lives (e.g. 11C: 20.4 min; 18F: 109.8 min) which may limit both the synthesis procedures and the time frame of PET studies. Iodine-124 (124I, t1/2 = 4.2 d) is an alternative long-lived PET radionuclide attracting increasing interest for long term clinical and small animal PET studies. The present review gives a survey on the use of 124I as promising PET radionuclide for molecular imaging. The first part describes the production of 124I. The second part covers basic radiochemistry with 124I focused on the synthesis of 124I-labeled compounds for molecular imaging purposes. The review concludes with a summary and an outlook on the future prospective of using the long-lived positron emitter 124I in the field of organic PET chemistry and molecular imaging.

  14. Gravitational mass of positron from LEP synchrotron losses

    PubMed Central

    Kalaydzhyan, Tigran

    2016-01-01

    General relativity(GR) is the current description of gravity in modern physics. One of the cornerstones of GR, as well as Newton’s theory of gravity, is the weak equivalence principle (WEP), stating that the trajectory of a freely falling test body is independent of its internal structure and composition. WEP is known to be valid for the normal matter with a high precision. However, due to the rarity of antimatter and weakness of the gravitational forces, the WEP has never been confirmed for antimatter. The current direct bounds on the ratio between the gravitational and inertial masses of the antihydrogen do not rule out a repulsive nature for the antimatter gravity. Here we establish an indirect bound of 0.13% on the difference between the gravitational and inertial masses of the positron (antielectron) from the analysis of synchrotron losses at the Large Electron-Positron collider (LEP). This serves as a confirmation of the conventional gravitational properties of antimatter without common assumptions such as, e.g., coupling of gravity to virtual particles, dynamics of distant astrophysical sources and the nature of absolute gravitational potentials. PMID:27461548

  15. Small Explorer (SMEX) POsitron Electron Magnet Spectrometer (POEMS)

    NASA Technical Reports Server (NTRS)

    LHeureux, Jacques; Evenson, Paul A.; Aleman, R. (Technical Monitor)

    1995-01-01

    This report covers the activities of Louisiana State University (LSU) under subcontract 26053-EX between LSU and the Bartol Research Institute (Bartol), which began January 1, 1994. The purpose of this subcontract was for LSU to participate in and support Bartol in the work to define the SMEX (Small Explorer)/POEMS (Positron Electron Magnet Spectrometer) spaceflight mission under NASA Contract NAS5-38098 between NASA and Bartol. The conclusions of this study were that for a 1998 launch into a 600km altitude, 98 degrees, approximately sun synchronous orbit, (a) the total radiation dose would be typically a few k-rad per year, certainly less than 20 k-rad per year for the anticipated shielding and potential solar flare environment, (b) detector counting rates would be dominated by the South Atlantic Anomaly (SAA) and the horns of the Van Allen belts, (c) the galactic electron and positron 'signal' can be extracted from the albedo background and the trapped populations by detailed evaluation of the geomagnetic transmission function (cut-off) for each event, (d) POEMS could make significant contributions to magnetospheric science if sufficient downlink capacity were provided and, (e) a fully functioning, cost efficient, data processing and analysis facility design was developed for the mission. Overall, POEMS was found to be a relatively simple experiment to manifest, operate and analyze and had potential for fundamental new discoveries in cosmic, heliospheric, solar and magnetospheric science.

  16. Gravitational mass of positron from LEP synchrotron losses

    SciTech Connect

    Kalaydzhyan, Tigran

    2016-07-27

    General relativity(GR) is the current description of gravity in modern physics. One of the cornerstones of GR, as well as Newton’s theory of gravity, is the weak equivalence principle (WEP), stating that the trajectory of a freely falling test body is independent of its internal structure and composition. WEP is known to be valid for the normal matter with a high precision. However, due to the rarity of antimatter and weakness of the gravitational forces, the WEP has never been confirmed for antimatter. The current direct bounds on the ratio between the gravitational and inertial masses of the antihydrogen do not rule out a repulsive nature for the antimatter gravity. Here we establish an indirect bound of 0.13% on the difference between the gravitational and inertial masses of the positron (antielectron) from the analysis of synchrotron losses at the Large Electron-Positron collider (LEP). As a result, this serves as a confirmation of the conventional gravitational properties of antimatter without common assumptions such as, e.g., coupling of gravity to virtual particles, dynamics of distant astrophysical sources and the nature of absolute gravitational potentials.

  17. Gravitational mass of positron from LEP synchrotron losses

    DOE PAGES

    Kalaydzhyan, Tigran

    2016-07-27

    General relativity(GR) is the current description of gravity in modern physics. One of the cornerstones of GR, as well as Newton’s theory of gravity, is the weak equivalence principle (WEP), stating that the trajectory of a freely falling test body is independent of its internal structure and composition. WEP is known to be valid for the normal matter with a high precision. However, due to the rarity of antimatter and weakness of the gravitational forces, the WEP has never been confirmed for antimatter. The current direct bounds on the ratio between the gravitational and inertial masses of the antihydrogen domore » not rule out a repulsive nature for the antimatter gravity. Here we establish an indirect bound of 0.13% on the difference between the gravitational and inertial masses of the positron (antielectron) from the analysis of synchrotron losses at the Large Electron-Positron collider (LEP). As a result, this serves as a confirmation of the conventional gravitational properties of antimatter without common assumptions such as, e.g., coupling of gravity to virtual particles, dynamics of distant astrophysical sources and the nature of absolute gravitational potentials.« less

  18. Adiabatic-nuclei calculations of positron scattering from molecular hydrogen

    NASA Astrophysics Data System (ADS)

    Zammit, Mark C.; Fursa, Dmitry V.; Savage, Jeremy S.; Bray, Igor; Chiari, Luca; Zecca, Antonio; Brunger, Michael J.

    2017-02-01

    The single-center adiabatic-nuclei convergent close-coupling method is used to investigate positron collisions with molecular hydrogen (H2) in the ground and first vibrationally excited states. Cross sections are presented over the energy range from 1 to 1000 eV for elastic scattering, vibrational excitation, total ionization, and the grand total cross section. The present adiabatic-nuclei positron-H2 scattering length is calculated as A =-2.70 a0 for the ground state and A =-3.16 a0 for the first vibrationally excited state. The present elastic differential cross sections are also used to "correct" the low-energy grand total cross-section measurements of the Trento group [A. Zecca et al., Phys. Rev. A 80, 032702 (2009), 10.1103/PhysRevA.80.032702] for the forward-angle-scattering effect. In general, the comparison with experiment is good. By performing convergence studies, we estimate that our Rm=1.448 a0 fixed-nuclei results are converged to within ±5 % for the major scattering integrated cross sections.

  19. PREFACE 12th International Workshop on Slow Positron Beam Techniques

    NASA Astrophysics Data System (ADS)

    Buckman, Stephen; Sullivan, James; White, Ronald

    2011-01-01

    Preface These proceedings arose from the 12th International Workshop on Slow Positron Beam Techniques (SLOPOS12), which was held on Magnetic Island, North Queensland, Australia, between 1-6th August 2010. Meetings in the SLOPOS series are held (roughly) every three years and have now been held on (almost) all continents, indicating the truly international nature of the field. SLOPOS12 marked the second time that the Workshop had been held in the southern hemisphere, and the first time in Australia. SLOPOS12 attracted 122 delegates from 16 countries. Most encouraging was the attendance of 28 student delegates, and that about half of the overall delegates were early career researchers - a good sign for the future of our field. We also enjoyed the company of more than a dozen partners and families of delegates. In a slight departure from previous SLOPOS meetings, the International Advisory Committee approved a broader scope of scientific topics for inclusion in the program for the 2010 Workshop. This broader scope was intended to capture the applications of positrons in atomic, molecular and biomedical areas and was encapsulated in the byeline for SLOPOS-12: The 12th International Workshop on Slow Positron Beam Techniques for Solids, Surfaces, Atoms and Molecules. The scientific and social program for the meeting ran over 6 days with delegates gathering on Sunday August 1st and departing on August 6th. The scientific program included plenary, invited, contributed and student lectures, the latter being the subject of a student prize. In all there were 53 oral presentations during the week. There were also two poster sessions, with 63 posters exhibited, and a prize was awarded for the best poster by a student delegate. The standard of the student presentations, both oral and posters, was outstanding, so much so that the judging panel recommended an additional number of prizes be awarded. Topics that were the focus of invited presentations and contributed papers at

  20. Calculation of Positron Binding Energies and Electron-Positron Annihilation Rates for Atomic Systems with the Reduced Explicitly Correlated Hartree-Fock Method in the Nuclear-Electronic Orbital Framework.

    PubMed

    Brorsen, Kurt R; Pak, Michael V; Hammes-Schiffer, Sharon

    2017-01-19

    Although the binding of a positron to a neutral atom has not been directly observed experimentally, high-level theoretical methods have predicted that a positron will bind to a neutral atom. In the present study, the binding energies of a positron to lithium, sodium, beryllium, and magnesium, as well as the electron-positron annihilation rates for these systems, are calculated using the reduced explicitly correlated Hartree-Fock (RXCHF) method within the nuclear-electronic orbital (NEO) framework. Due to the lack of explicit electron-positron correlation, NEO Hartree-Fock and full configuration interaction calculations with reasonable electronic and positronic basis sets do not predict positron binding to any of these atoms. In contrast, the RXCHF calculations predict positron binding energies and electron-positron annihilation rates in qualitative agreement with previous highly accurate but computationally expensive stochastic variational method calculations. These results illustrate that the RXCHF method can successfully describe the binding of a positron to a neutral species with no dipole moment. Moreover, the RXCHF method will be computationally tractable for calculating positron binding to molecular systems. The RXCHF approach offers a balance of accuracy and computational tractability for studying these types of positronic systems.