  1. Measurement quality assurance for beta particle calibrations at NIST

    SciTech Connect

    Soares, C.G.; Pruitt, J.S.

    1993-12-31

    Standardized beta-particle fields have been established in an international standard and have been adopted for use in several U.S. dosimeter and instrument testing standards. Calibration methods and measurement quality assurance procedures employed at the National Institute of Standards and Technology (NIST) for beta-particle calibrations in these reference fields are discussed. The calibration facility including the NIST-automated extrapolation ionization chamber is described, and some sample results of calibrations are shown. Methods for establishing and maintaining traceability to NIST of secondary laboratories are discussed. Currently, there are problems in finding a good method for routine testing of traceability to NIST. Some examples of past testing methods are given and solutions to this problem are proposed.

  2. Dose Rate Calibration of a Commercial Beta-Particle Irradiator Used In Archeological and Geological Dating

    SciTech Connect

    Bernal, S.M.

    2004-10-31

    The 801E Multiple Sample Irradiator, manufactured by Daybreak Nuclear Systems, is capable of exposing up to 30 samples to beta radiation by placing each sample one by one directly beneath a heavily shielded ceramic Sr-90/Y-90 source and opening a specially designed shutter. Daybreak Nuclear Systems does not provide the {sup 90}Sr/{sup 90}Y dose rate to the sample because of variations of up to 20% in the nominal activity of the beta sources (separately manufactured by AEA Technology). Thus it is left to the end user to determine. Here aluminum oxide doped with carbon (Al{sub 2}O{sub 3}:C), in the form of Landauer's Luxel{trademark}, was irradiated to different known doses using a calibrated {sup 90}Sr/{sup 90}Y beta particle irradiator, and the OSL signal monitored after each irradiation to generate a calibration curve. Comparison of the OSL Signal from the unknown 801E Irradiator dose with the calibration curve enabled the dose and therefore dose rate to be determined. The timing accuracy of the 801E Irradiator was also evaluated and found to be +/- 0.5 seconds. The dose rate of the beta source was found to be 0.147 +/- 0.007 Gy/s.

  3. Calibration of the Malvern particle sizer

    NASA Technical Reports Server (NTRS)

    Dodge, L. G.

    1984-01-01

    A relatively simple technique has been developed to calibrate particle- and droplet-sizing instruments manufactured by Malvern and other similar Fraunhofer diffraction particle-sizing instruments. Measurements of standard reticles using an instrument calibrated in this manner demonstrate the effectiveness of the procedure. In addition, guidelines are presented to avoid errors due to vignetting of the scattered light signal.

  4. Gamma-ray blind beta particle probe

    DOEpatents

    Weisenberger, Andrew G.

    2001-01-01

    An intra-operative beta particle probe is provided by placing a suitable photomultiplier tube (PMT), micro channel plate (MCP) or other electron multiplier device within a vacuum housing equipped with: 1) an appropriate beta particle permeable window; and 2) electron detection circuitry. Beta particles emitted in the immediate vicinity of the probe window will be received by the electron multiplier device and amplified to produce a detectable signal. Such a device is useful as a gamma insensitive, intra-operative, beta particle probe in surgeries where the patient has been injected with a beta emitting radiopharmaceutical. The method of use of such a device is also described, as is a position sensitive such device.

  5. Automated calibration of a flight particle spectrometer

    NASA Technical Reports Server (NTRS)

    Torbert, R. B.

    1986-01-01

    A system for calibrating both electron and ion imaging particle spectrometers was devised to calibrate flight instruments in a large vacuum facility in the Space Science Laboratory at the Marshall Space Flight Center. An IBM-compatible computer was used to control, via an IEEE 488 buss protocol, a two-axis gimbled table, constructed to fit inside the tank. Test settings of various diagnostic voltages were also acquired via the buss. These spectrometers constructed by the author at UCSD were calibrated in an automatic procedure programmed on the small computer. Data was up-loaded to the SSL VAX where a program was developed to plot the results.

  6. Beta particle monitor for surfaces

    DOEpatents

    MacArthur, Duncan W.

    1997-01-01

    A beta radiation detector which is capable of reliably detecting beta radiation emitted from a surface. An electrically conductive signal collector is adjustably mounted inside an electrically conductive enclosure which may define a single large opening for placing against a surface. The adjustable mounting of the electrically conductive signal collector can be based on the distance from the surface or on the expected beta energy range. A voltage source is connected to the signal collector through an electrometer or other display means for creating an electric field between the signal collector and the enclosure. Air ions created by the beta radiation are collected and the current produced is indicated on the electrometer or other display means.

  7. Beta particle monitor for surfaces

    DOEpatents

    MacArthur, D.W.

    1997-10-21

    A beta radiation detector which is capable of reliably detecting beta radiation emitted from a surface. An electrically conductive signal collector is adjustably mounted inside an electrically conductive enclosure which may define a single large opening for placing against a surface. The adjustable mounting of the electrically conductive signal collector can be based on the distance from the surface or on the expected beta energy range. A voltage source is connected to the signal collector through an electrometer or other display means for creating an electric field between the signal collector and the enclosure. Air ions created by the beta radiation are collected and the current produced is indicated on the electrometer or other display means. 2 figs.

  8. Calibration of optical particle-size analyzer

    DOEpatents

    Pechin, William H.; Thacker, Louis H.; Turner, Lloyd J.

    1979-01-01

    This invention relates to a system for the calibration of an optical particle-size analyzer of the light-intercepting type for spherical particles, wherein a rotary wheel or disc is provided with radially-extending wires of differing diameters, each wire corresponding to a particular equivalent spherical particle diameter. These wires are passed at an appropriate frequency between the light source and the light detector of the analyzer. The reduction of light as received at the detector is a measure of the size of the wire, and the electronic signal may then be adjusted to provide the desired signal for corresponding spherical particles. This calibrator may be operated at any time without interrupting other processing.

  9. Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

    SciTech Connect

    McIntyre, Justin I.; Schrom, Brian T.; Cooper, Matthew W.; Haas, Derek A.; Hayes, James C.

    2009-09-21

    Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

  10. Test-Aerosol Generator For Calibrating Particle Counters

    NASA Technical Reports Server (NTRS)

    Mogan, Paul A.; Adams, Alois J.; Schwindt, Christian J.; Hodge, Timothy R.; Mallow, Tim J.; Duong, Anh A.; Bukauskas, Vyto V.

    1996-01-01

    Apparatus generates clean, stable aerosol stream for use in testing and calibrating laser-based aerosol-particle counter. Size and concentration of aerosol particles controlled to ensure accurate calibration. Cheap, widely available medical nebulizers used to generate aerosols.

  11. Towards a Precise Energy Calibration of the CUORE Double Beta Decay Experiment

    NASA Astrophysics Data System (ADS)

    Dally, Adam G.

    The mass of the neutrino may hold the key to many problems in cosmology and astrophysics. The observation of neutrino oscillations shows that neutrinos have mass, which was something that was not accounted for in the Standard Model of particle physics. This thesis covers topics relating to measuring the value of neutrino mass directly using bolometers. The first section will discuss the neutrino mass and different experiments for measuring the mass using bolometers. The mass of the neutrino can be measured directly from beta-decay or inferred from observation of neutrinoless double beta decay (0nubetabeta). In this work I present Monte Carlo and analytic simulation of the MARE experiment including, pile-up and energy resolution effects. The mass measurement limits of a micro-calorimeter experiments as it relates to the quantity of decays measured is provided. A similar simulation is preformed for the HolMES experiment. The motivation is to determine the sensitivity of such experiments and the detector requirements to reach the goal sensitivity. Another possible method for determining the neutrino mass is to use neutrinoless double beta decay. The second section will cover the Cryogenic Underground Observatory for Rare Events (CUORE) detector calibration system (DCS). CUORE is a neutrinoless double beta decay (0nubetabeta) experiment with an active mass of 206 kg of 130Te. The detector consists of 988 TeO2 bolometers operating at 10 mK. The signature of 0 nubetabeta decay is an excess of events at the Q-value of 2528 keV. Understanding the energy response is critical for event identification, but this presents many challenges. Calibration is necessary to associate a known energy from a gamma with a voltage pulse from the detector. The DCS must overcome many design challenges. The calibration source must be placed safely and reliable within the detector. The temperature of the detector region of the cryostat must not be changed during calibration. To achieve this

  12. Calibration of single particle sizing velocimeters using photomask reticles

    NASA Technical Reports Server (NTRS)

    Hirleman, E. D.; Holve, D. J.; Hovenac, E. A.

    1988-01-01

    The development of photomask reticle calibration standards for single particle instruments is discussed. The calibration method studied involves the use of photomask reticles where the particle artifacts are actually disks of chrome thin film in the clear field reticles produced by photolithography and etching processes. Consideration is given to various aspects of theory, design, and performance.

  13. Automated calibration of a flight particle spectrometer

    NASA Technical Reports Server (NTRS)

    Torbert, Roy B.

    1986-01-01

    An automatic calibration system was designed for use in the vacuum facility at the Space Science Laboratory of the Marshall Space Flight Center. That system was developed and used in the intervening winter to calibrate the ion spectrometer that eventually flew in May 1986 aboard the NASA project, CRIT 1. During this summer, it is planned to implement the calibration of both an ion and electron spectrometer of a new design whose basic elements were conceived during the winter of 1985 to 1986. This spectrometer was completed in the summer and successfully mounted in the vacuum tank for calibration. However, the source gate valve malfunctioned, and, at the end of the summer, it still needed a replacement. During the inevitable delays in the experimental research, the numerical model of the Critical Velocity effect was completed and these results were presented.

  14. HgI2 low energy beta particle detector

    NASA Technical Reports Server (NTRS)

    Shah, K. S.; Squillante, M. R.; Entine, G.

    1990-01-01

    An HgI2 device structure was designed and tested which allows HgI2 to be used to make low-energy beta-particle detectors. The devices detected tritium beta particles with an efficiency of about 25 percent. A protective encapsulant has been developed which should protect the devices for up to 20 years and will attenuate only a small fraction of the beta particles. It is noted that the devices hold significant promise to provide a practical alternative to liquid scintillation counters and gas flow-through proportional counters.

  15. Microprocessor-based single particle calibration of scintillation counter

    NASA Technical Reports Server (NTRS)

    Mazumdar, G. K. D.; Pathak, K. M.

    1985-01-01

    A microprocessor-base set-up is fabricated and tested for the single particle calibration of the plastic scintillator. The single particle response of the scintillator is digitized by an A/D converter, and a 8085 A based microprocessor stores the pulse heights. The digitized information is printed. Facilities for CRT display and cassette storing and recalling are also made available.

  16. Preparation of calibrated test packages for particle impact noise detection

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.

  17. Charged-Particle Calibration Of Spacecraft-Ranging Signals

    NASA Technical Reports Server (NTRS)

    Nguyen, Tien M.

    1992-01-01

    Report discusses determination of effective densities of electrically charged particles along paths of microwave signals transmitted to and from spacecraft and use of those densities to calibrate measured signal-propagation times, used to compute distances between ground stations and spacecraft. Oriented toward selection of method of calibration optimal with respect to three criteria: minimization of range error and of root-mean-square uncertainty in range error; minimization of amount, complexity, and/or cost of equipment; and capability of calibrating changes in group velocities of signals on ranging channel.

  18. A Sr-90/Y-90 field calibrator for performance testing of beta-gamma survey instruments

    SciTech Connect

    Olsher, R.H.; Haynie, J.S.

    1988-01-01

    ANSI and regulatory agency guidelines prescribe periodic performance tests for radiation protection instrumentation. Reference readings should be obtained for one point on each scale or decade normally used. A small and lightweight calibrator has been developed that facilitates field testing of beta-gamma survey instruments. The calibrator uses a 45 microcurie Sr-90/Y-90 beta source with a filter wheel to generate variable dose rates in the range from 4 to 400 mrad/hr. Thus, several ranges may be checked by dialing in appropriate filters. The design, use, and typical applications of the calibrator are described.

  19. Self-absorption of tritium betas in metal tritide particles.

    PubMed

    Kropf, R F; Wang, Y; Cheng, Y S

    1998-10-01

    Inhaling metal tritide particles is a potential occupational hazard. The radiation dose to tissue from tritide particles depends on their solubility and retention in the body. In each tritide particle, a portion of the beta particles from decay of tritium is absorbed by the metal matrix and therefore cannot contribute to absorbed radiation dose to tissue. A theoretical model for estimating the self-absorption of tritium betas in spherical metal tritide particles is presented. Numerical calculations are made with this method for titanium, zirconium, and erbium particles from 0.5 to 50 microm in diameter. The tritium spectrum is divided into energy groups to facilitate estimation of the energy that escapes the particle for dose calculations. Our results show considerable absorption of beta particles and their energy, even for respirable particles smaller than 5 microm. Limited experimental data of self-absorption for titanium and zirconium tritides supported the theoretical calculation. It is concluded that the self-absorption factors should be required for counting tritide particle samples as well as for estimating absorbed radiation dose to tissue. PMID:9753363

  20. Calibration of the Solar Orbiter Energetic Particle Detector Suite

    NASA Astrophysics Data System (ADS)

    Wimmer-Schweingruber, R. F.; Rodriguez-Pacheco, J.; Martin-Garcia, C.; Kulkarni, S. R.; Panitzsch, L.; Boettcher, S.; Mason, G. M.; Kohler, J.; Ho, G. C.; Boden, S.; Grunau, J.; Steinhagen, J.; Terasa, C.; Yu, J.; Prieto, M.; Gomez-Herrero, R.; Blanco, J.

    2013-12-01

    We present the current status and plans for the calibration of the Energetic Particle Detector (EPD) suite on ESA's Solar Orbiter mission. Solar Orbiter is scheduled to launch in January 2017, instrument delivery in January 2015. EPD consists of four sensors: the SupraThermal Electron and Proton (STEP) sensor covers electrons (protons) from 2 (3) keV up to 100 keV, the Electron Proton Telescope (EPT) from 20 to 300 (7000) keV, the Suprathermal Ion Spectrograph (SIS) determines the ionic composition from ~0.05 to ~10 MeV/nuc (species dependent), and the High Energy Telescope (HET) measures electrons and protons (ions) from 0.3 to 30 and 10 to >100 MeV/nuc (20 - 200 MeV/nuc species dependent). EPT, HET, and SIS have two approximately opposite-facing fields of view, EPT, and HET share a common electronics box, two EPT/HET sensors allow the determination of second-order anisotropies (a total of 4 FoVs). Apart from the use of radioactive sources, STEP will be calibrated at the Kiel calibration facilities, EPT both at Kiel (electrons and low-energy protons) as well as at PTB in Braunschweig. SIS will undergo calibration at the LBL 88' cyclotron, HET at HIMAC in Chiba, Japan. Tests of the electron/protons discrimination of EPT show the expected behavior, HET prototypes have already been calibrated and the results will be shown.

  1. Further measurement of the {beta}-delayed {alpha}-particle emission of {sup 16}N

    SciTech Connect

    France III, R. H.; Wilds, E. L.; McDonald, J. E.; Gai, M.

    2007-06-15

    We measured the {beta}-delayed {alpha}-particle emission spectrum of {sup 16}N with a sensitivity for {beta}-decay branching ratios of the order of 10{sup -10}. The {sup 16}N nuclei were produced using the d({sup 15}N,{sup 16}N)p reaction with 70 MeV {sup 15}N beams and a deuterium gas target 7.5 cm long at a pressure of 1250 torr. The {sup 16}N nuclei were collected (over 10 s) using a thin aluminum foil with an areal density of 180 {mu}g/cm{sup 2} tilted at 7 deg. with respect to the beam. The activity was transferred to the counting area by means of a stepping motor in less than 3 s with the counting carried out over 8 s. The {beta}-delayed {alpha}-particles were measured using a time-of-flight method to achieve a sufficiently low background. Standard calibration sources ({sup 148}Gd, {sup 241}Am, {sup 208,209}Po, and {sup 227}Ac) as well as {alpha} particles and {sup 7}Li from the {sup 10}B(n,{alpha}){sup 7}Li reaction were used for an accurate energy calibration. The energy resolution of the catcher foil (180-220 keV) was calculated and the time-of-flight resolution (3-10 nsec) was measured using the {beta}-delayed {alpha}-particle emission from {sup 8}Li that was produced using the d({sup 7}Li,{sup 8}Li)p reaction with the same setup. The line shape was corrected to account for the variation in the energy and time resolution and a high statistics spectrum of the {beta}-delayed {alpha}-particle emission of {sup 16}N is reported. However, our data (as well as earlier Mainz data and unpublished Seattle data) do not agree with an earlier measurement of the {beta}-delayed {alpha}-particle emission of {sup 16}N taken at TRIUMF after averaging over the energy resolution of our collection system. This disagreement, among other issues, prohibits accurate inclusion of the f-wave component in the R-matrix analysis.

  2. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    SciTech Connect

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low {sup 40}K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using {sup 40}K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec-{sup -1} and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices.

  3. Tumor dosimetry in radioimmunotherapy: Methods of calculation for beta particles

    SciTech Connect

    Leichner, P.K. ); Kwok, C.S. )

    1993-03-01

    Calculational methods of beta-particle dosimetry in radioimmunotherapy (RIT) are reviewed for clinical and experimental studies and computer modeling of tumors. In clinical studies, absorbed-dose estimates are usually based on the [ital in]-[ital vivo] quantitation of the activity in tumors from gamma camera images. Because of the limited spatial resolution of gamma cameras, clinical dosimetry is necessarily limited to the macroscopic level (macrodosimetry) and the MIRD formalism for absorbed-dose calculations is appropriate. In experimental RIT, tumor dimensions are often comparable to or smaller than the beta-particle range of commonly used radionuclides (for example, [sup 131]I, [sup 67]Cu, [sup 186]Re, [sup 188]Re, [sup 90]Y) and deviations from the equilibrium dose must be taken into account in absorbed-dose calculations. Additionally, if small tumors are growing rapidly at the time of RIT, the effects of tumor growth will need to be included in absorbed-dose estimates. In computer modeling of absorbed-dose distributions, analytical, numerical, and Monte Carlo methods have been used to investigate the consequences of uniform and nonuniform activity distributions and the effects of inhomogeneous media. Measurements and calculations of the local absorbed dose at the multicellular level have shown that variations in this dose are large. Knowledge of the absorbed dose is essential for any form of radiotherapy. Therefore, it is important that clinical, experimental, and theoretical investigations continue to provide information on tumor dosimetry that is necessary for a better understanding of the radiobiological effects of RIT.

  4. Monte Carlo based calibration of an air monitoring system for gamma and beta+ radiation.

    PubMed

    Sarnelli, A; Negrini, M; D'Errico, V; Bianchini, D; Strigari, L; Mezzenga, E; Menghi, E; Marcocci, F; Benassi, M

    2015-11-01

    Marinelli beaker systems are used to monitor the activity of radioactive samples. These systems are usually calibrated with water solutions and the determination of the activity in gases requires correction coefficients accounting for the different mass-thickness of the sample. For beta+ radionuclides the different distribution of the positrons annihilation points should be also considered. In this work a Monte Carlo simulation based on Geant4 is used to compute correction coefficients for the measurement of the activity of air samples. PMID:26356044

  5. Cerenkov radiation imaging as a method for quantitative measurements of beta particles in a microfluidic chip

    PubMed Central

    Cho, Jennifer S; Taschereau, Richard; Olma, Sebastian; Liu, Kan; Chen, Yi-Chun; Shen, Clifton K-F; van Dam, R Michael; Chatziioannou, Arion F.

    2009-01-01

    It has been observed that microfluidic chips used for synthesizing 18F-labeled compounds demonstrate visible light emission without nearby scintillators or fluorescent materials. The origin of the light was investigated and found to be consistent with the emission characteristics from Cerenkov radiation. Since 18F decays through the emission of high-energy positrons, the energy threshold for beta particles, i.e., electrons or positrons, to generate Cerenkov radiation was calculated for water and polydimethylsiloxane (PDMS), the most commonly used polymer-based material for microfluidic chips. Beta particles emitted from 18F have a continuous energy spectrum, with a maximum energy that exceeds this energy threshold for both water and PDMS. In addition, the spectral characteristics of the emitted light from 18F in distilled water were also measured, yielding a broad distribution from 300 nm to 700 nm, with higher intensity at shorter wavelengths. A photograph of the 18F solution showed a bluish-white light emitted from the solution, further suggesting Cerenkov radiation. In this study, the feasibility of using this Cerenkov light emission as a method for quantitative measurements of the radioactivity within the microfluidic chip in situ was evaluated. A detector previously developed for imaging microfluidic platforms was used. The detector consisted of a charge coupled device (CCD) optically coupled to a lens. The system spatial resolution, minimum detectable activity and dynamic range were evaluated. In addition, a calibration of Cerenkov signal versus activity concentration in the microfluidic chip was determined. This novel method of Cerenkov radiation measurements will provide researchers with a simple yet robust quantitative imaging tool for microfluidic applications utilizing beta particles. PMID:19847018

  6. Calibration of particle position on digital holography using transparent resin block with dispersed particles

    NASA Astrophysics Data System (ADS)

    Tanaka, Y.; Yoshino, T.; Harada, D.; Murata, S.

    2009-11-01

    This paper describes the use of a Calibration Block (CB) for evaluating the accuracy of digital holography in particle position measurement. CB made of acrylic has three layers and the gap between the layers is filled with transparent resin. The refractive index of the resin and the layers is almost the same (1.49). Fin Block (FB), which is not filled with resin, is introduced in order to evaluate effects of the resin. The fringe edges of several holographic patterns are observed by using three kinds of CB and FB. Each layer is coated with spherical particles (diameter: 16.36 ± 0.42 μ m). The influence of multiple scattering on the detected depth of the particles is evaluated by changing the number density of particles. Three kinds of CB and FB are prepared (averaged particle density in the holographic pattern; 83.2, 166.5 and 249.7). The fringe edges of the holographic patterns generated in CB and FB are observed, respectively. It is found that the fringe edges of CB are clearer than FB. Also, Multiple scattering acts as a source of background noise with high spatial frequency, which has almost the same frequency as that of the particle diffraction on the fringe patterns, and reduces the effective signal-to-noise ratio of the holographic pattern. CB can be used to evaluate the influence of multiple scattering on the detected particle depth.

  7. Compact Beta Particle/Positron Imager for Plant Biology

    SciTech Connect

    Weisenberger, Andrew; Lee, Seung Joon; McKisson, John; Xi, Wenze; Zorn, Carl; Stolin, Alexander; Majewski, Stan; Majewski, Stanislaw; Howell, Calvin; Crowell, Alec; Smith, Mark

    2011-06-01

    The 11CO2 tracer is used to facilitate plant biology research towards optimization of plant productivity, biofuel development and carbon sequestration in biomass. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using 11CO2. Plants typically have very thin leaves resulting in little medium for the emitted positrons to undergo an annihilation event. For the emitted positron from 11C decay approximately 1mm of water equivalent material is needed for positron annihilation. Thus most of the positrons do not annihilate inside the leaf, resulting in limited sensitivity for PET imaging. To address this problem we have developed a compact beta-positive beta-minus particle (BPBM) imager for 11CO2 leaf imaging. The detector is based on a Hamamatsu H8500 position sensitive photomultiplier tube optically coupled via optical grease and a 3mm thick glass plate to a 0.5mm thick Eljin EJ-212 plastic scintillator. The detector is equipped with a flexible arm to allow its placement and orientation on the leaf of the plant of interest while maintaining the leaf's original orientation. We are planning to utilize the imaging device at the Duke University Phytotron to investigate dynamic carbon transport differences between invasive and native species.

  8. Beta particles sensitivity of an all-carbon detector

    NASA Astrophysics Data System (ADS)

    Pacilli, M.; Allegrini, P.; Conte, G.; Spiriti, E.; Ralchenko, V. G.; Komlenok, M.; Bolshakov, A.; Khomich, A. A.; Konov, V.

    2014-02-01

    The response of high quality polycrystalline diamond pixel detectors to 90Sr beta particles is reported. Laser induced surface graphitization was used to realize 36 conductive contacts with 1 mm×1 mm area each, pitch 1.2 mm, on one detector side whereas a 8 mm×8 mm large area graphite contact was realized on the other face for grounding or biasing. A proximity board was used to hold the matrix, the amplifiers and to bond nine pixels to test homogeneity of response among 36 detector pixels. Two configurations were used to test charge collection uniformity and signal dependence on voltage. Both configurations showed noise pedestal fitted with a Gaussian curve of 1150 equivalent electrons (1σ) and typical beta source particles spectrum. Reversing the bias polarity the pulse height distribution does not change and the saturation of most probable value of charge collection was observed around ±200 V (0.4 V/μm) with reasonable pixel response uniformity equal to a most probable value 1.28±0.05 fC. The charge collection efficiency (CCE) measurement was implemented using coincidence mode acquisition with an external trigger made by a commercial polycrystalline diamond slab. The detector shows a CCE=0.59 estimated using the 1 mm2 large graphite pixel. The information earned with this first prototype will be used to design the new board with amplifying electronics for reading all 36 pixels at a time and perform experiments with monochromatic high energy electrons.

  9. Method and apparatus for calibrating a particle emissions monitor

    DOEpatents

    Flower, William L.; Renzi, Ronald F.

    1998-07-07

    The instant invention discloses method and apparatus for calibrating particulate emissions monitors, in particular, and sampling probes, in general, without removing the instrument from the system being monitored. A source of one or more specific metals in aerosol (either solid or liquid) or vapor form is housed in the instrument. The calibration operation is initiated by moving a focusing lens, used to focus a light beam onto an analysis location and collect the output light response, from an operating position to a calibration position such that the focal point of the focusing lens is now within a calibration stream issuing from a calibration source. The output light response from the calibration stream can be compared to that derived from an analysis location in the operating position to more accurately monitor emissions within the emissions flow stream.

  10. Method and apparatus for calibrating a particle emissions monitor

    DOEpatents

    Flower, W.L.; Renzi, R.F.

    1998-07-07

    The invention discloses a method and apparatus for calibrating particulate emissions monitors, in particular, sampling probes, and in general, without removing the instrument from the system being monitored. A source of one or more specific metals in aerosol (either solid or liquid) or vapor form is housed in the instrument. The calibration operation is initiated by moving a focusing lens, used to focus a light beam onto an analysis location and collect the output light response, from an operating position to a calibration position such that the focal point of the focusing lens is now within a calibration stream issuing from a calibration source. The output light response from the calibration stream can be compared to that derived from an analysis location in the operating position to more accurately monitor emissions within the emissions flow stream. 6 figs.

  11. Calibration of Parameters in Beta-Delta HMX Phase Transformation Kinetics Using Computer Simulations

    SciTech Connect

    Wemhoff, A P; Burnham, A K

    2005-11-17

    The kinetics of the beta-delta solid-solid phase transformation of HMX (nitramine octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) were modeled in ALE2D using four similar equilibrium-inhibited nucleation-growth models: a reversible set of Arrhenius kinetics following a LANL model, and three sets of kinetics derived based on an autocatalytic model using the bidirectional reaction formalism. The parameters for the bidirectional kinetics models were calibrated using simulations of two experimental setup scenarios where experimental data is available: 165 C XRD and SITI. In this calibration, the transition enthalpy and activation energy values were kept constant, while the frequency factors were iterated to achieve results similar to those provided by the experiments. This process yielded six unique sets of kinetic parameters that describe the phase transformation: a pair of sets for each of the three bidirectional kinetics models. The models calibrated using 165 C XRD data showed good agreement with LX-04 STEX experimental results, while the SITI-based models were in good agreement with the LANL model and PBX-9501 STEX experimental data. These bidirectional models were also shown to require less computational effort than the LANL model.

  12. Change of calibration of diffraction-based particle sizers in dense sprays

    NASA Technical Reports Server (NTRS)

    Dodge, L. G.

    1984-01-01

    A calibration procedure for diffraction-based particle-sizing instruments using multielement detectors is briefly reviewed. The effects of multiple scattering due to dense sprays on the calibration of these instruments are then examined over a range of sprays with Sauter mean diameters from 20 to 55 microns. An empirical scheme to correct for changes in calibration due to dense sprays or other scattering media is presented.

  13. Direct Reading Particle Counters: Calibration Verification and Multiple Instrument Agreement via Bump Testing

    SciTech Connect

    Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.; Hollenbeck, Scott

    2015-01-27

    We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The method consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.

  14. Direct Reading Particle Counters: Calibration Verification and Multiple Instrument Agreement via Bump Testing.

    PubMed

    Jankovic, John; Zontek, Tracy L; Ogle, Burton R; Hollenbeck, Scott

    2015-01-01

    The calibration records of two direct reading instruments designated as condensation particle counters were examined to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. Both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Therefore, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The method consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. The bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.

  15. [Development and Performance Evaluation of a Supermicron Particle Generation System for Aerosol Instrument Calibration].

    PubMed

    Chen, Xiao-tong; Jiang, Jing-kun; Deng, Jian-guo; Duan, Lei; Hao, Ji-ming

    2016-03-15

    Accurate calibration of aerosol measurement instruments is critical for ensuring the data quality when sampling ambient particulate matter (PM) or those from emission sources. A system for calibrating these instruments was set up, which included an ultrasonic device to generate polydisperse supermicron particles, a chamber, and an aerodynamic particle spectrometer to measure particle size distribution. We verified its performance in stably generated testing aerosol with good spatial uniformity, controlled size distributions and concentrations. The testing aerosol generated had a lognormal distribution. A PM₁₀ and PM₂.₅ two-stage virtual impactor was calibrated using this online method. Collection efficiencies of PM₁₀ and PM₂.₅ stages calibrated by an off-line method using monodisperse particles were also used for comparison. The results from two different methods were consistent with each other. Though the off-line method has been widely used to calibrate PM samplers, it suffers from long experimental duration (2-3 days for calibrating one sampler). In contrast, the online method allows for a rapid calibration (less than half a day for calibrating one sampler). PMID:27337867

  16. Calibration of TSI model 3025 ultrafine condensation particle counter

    SciTech Connect

    Kesten, J.; Reineking, A.; Porstendoerfer, J. )

    1991-01-01

    The registration efficiency of the TSI model 3025 ultrafine condensation particle counter for Ag and NaCl particles of between 2 and 20 nm in diameter was determined. Taking into account the different shapes of the input aerosol size distributions entering the differential mobility analyzer (DMA) and the transfer function of the DMA, the counting efficiencies of condensation nucleus counters (CNC) for monodisperse Ag and NaCl particles were estimated. In addition, the dependence of the CNC registration efficiency on the particle concentration was investigated.

  17. Extension of gravity center method for diameter calibration of polystyrene standard particles with a metrological AFM

    NASA Astrophysics Data System (ADS)

    Misumi, Ichiko; Takahata, Keiji; Sugawara, Kentaro; Gonda, Satoshi; Ehara, Kensei

    2012-06-01

    In the particle diameter calibration using metrological AFM, the distance between center points of neighboring two particles is referred to as "lateral diameter" when a single-layer close-packed structure of particles is successfully formed. The distance between an apex of a particle and a substrate is referred to as "vertical diameter." In the previous studies, lateral diameter was calculated by manually selecting and extracting a line profile from metrological AFM data and directly applying a method to calculate a pitch of one-dimensional grating. As the manual line profile extraction depends on who does it, however, there is a possibility that calculated lateral diameter is varied from person to person. We developed a technology to calibrate diameter of polystyrene latex (PSL) particles by using our metrological AFM. In this study, the gravity center method is extended to three dimensions to calculate position of and the center of gravity in each particle. Lateral diameter, which was defined as distance between gravity centers of neighboring two particles, is calibrated and uncertainty in the lateral diameter calibration is evaluated. Deformation of particles was also estimated by using Young's modulus of thin film PSL and bulk PSL.

  18. Calibration of particle detectors for secondary cosmic rays using gamma-ray beams from thunderclouds

    NASA Astrophysics Data System (ADS)

    Chilingarian, A.; Chilingaryan, S.; Hovsepyan, G.

    2015-09-01

    After observation of hundreds of Thunderstorm Ground Enhancements (TGEs) we measure energy spectra of particles originated in clouds and directed towards Earth. We use these "beams" for calibration of cosmic ray detectors located beneath the clouds at an altitude of 3200 m at Mount Aragats in Armenia. The calibrations of particle detectors with fluxes of TGE gamma rays are in good agreement with simulation results and allow estimation of the energy thresholds and efficiencies of numerous particle detectors used for studying galactic and solar cosmic rays.

  19. Method, apparatus and system for low-energy beta particle detection

    DOEpatents

    Akers, Douglas W.; Drigert, Mark W.

    2012-09-25

    An apparatus, method, and system relating to radiation detection of low-energy beta particles are disclosed. An embodiment includes a radiation detector with a first scintillator and a second scintillator operably coupled to each other. The first scintillator and the second scintillator are each structured to generate a light pulse responsive to interaction with beta particles. The first scintillator is structured to experience full energy deposition of low-energy beta particles, and permit a higher-energy beta particle to pass therethrough and interact with the second scintillator. The radiation detector further includes a light-to-electrical converter operably coupled to the second scintillator and configured to convert light pulses generated by the first scintillator and the second scintillator into electrical signals. The first scintillator and the second scintillator have at least one mutually different characteristic to enable an electronic system to determine whether a given light pulse is generated in the first scintillator or the second scintillator.

  20. Calibration and Laboratory Test of the Department of Energy Cloud Particle Imager

    SciTech Connect

    McFarquhar, GM; Um, J

    2012-02-17

    Calibration parameters from the Connolly et al. (2007) algorithm cannot be applied to the Department of Energy's (DOE) CPI because the DOE CPI is version 2.0. Thus, Dr. Junshik Um and Prof. Greg McFarquhar brought the DOE CPI to the University of Manchester, UK, where facilities for calibrating it were available. In addition, two other versions of CPIs (1.0 and 1.5) were available on-site at the University of Manchester so that an intercomparison of three different versions of the CPI was possible. The three CPIs (versions 1.0, 1.5, and 2.0) were calibrated by moving glass calibration beads and ice analogues of known size parallel to the object plane. The distance between the object plane and a particle, the particle's focus, its apparent maximum dimension, and a background image were measured in order to derive calibration parameters for each CPI version. The calibration parameters are used in two empirical equations that are applied to in situ CPI data to determine particle size and depth of field, and hence particle size distributions (PSDs). After the tests with the glass calibration beads to derive the calibration parameters, the three CPIs were installed at the base of the Manchester Ice Cloud Chamber and connected to air pumps that drew cloud through the sample volume. Warm liquid clouds at a temperature of 1-2 C and ice clouds at a temperature of -5 C were generated, and the resulting PSDs for each of the CPIs were determined by applying the results of each calibration.

  1. Full bandwidth calibration procedure for acoustic probes containing a pressure and particle velocity sensor.

    PubMed

    Basten, Tom G H; de Bree, Hans-Elias

    2010-01-01

    Calibration of acoustic particle velocity sensors is still difficult due to the lack of standardized sensors to compare with. Recently it is shown by Jacobsen and Jaud [J. Acoust. Soc. Am. 120, 830-837 (2006)] that it is possible to calibrate a sound pressure and particle velocity sensor in free field conditions at higher frequencies. This is done by using the known acoustic impedance at a certain distance of a spherical loudspeaker. When the sound pressure is measured with a calibrated reference microphone, the particle velocity can be calculated from the known impedance and the measured pressure. At lower frequencies, this approach gives unreliable results. The method is now extended to lower frequencies by measuring the acoustic pressure inside the spherical source. At lower frequencies, the sound pressure inside the sphere is proportional to the movement of the loudspeaker membrane. If the movement is known, the particle velocity in front of the loudspeaker can be derived. This low frequency approach is combined with the high frequency approach giving a full bandwidth calibration procedure which can be used in free field conditions using a single calibration setup. The calibration results are compared with results obtained with a standing wave tube.

  2. Calibration and Readiness of the ISS-RAD Charged Particle Detector

    NASA Technical Reports Server (NTRS)

    Rios, R.

    2015-01-01

    The International Space Station (ISS) Radiation Assessment Detector (RAD) is an intravehicular energetic particle detector designed to measure a broad spectrum of charged particle and neutron radiation unique to the ISS radiation environment. In this presentation, a summary of calibration and readiness of the RAD Sensor Head (RSH) - also referred to as the Charged Particle Detector (CPD) - for ISS will be presented. Calibration for the RSH consists of p, He, C, O, Si, and Fe ion data collected at the NASA Space Radiation Laboratory (NSRL) and Indiana University Cyclotron Facility (IUCF). The RSH consists of four detectors used in measuring the spectroscopy of charged particles - A, B, C, and D; high-energy neutral particles and charged particles are measured in E; and the last detector - F - is an anti-coincidence detector. A, B, and C are made from Si; D is made from BGO; E and F are made from EJ260XL plastic scintillator.

  3. Calibration of H-alpha/H-beta Indexes for Emission Line Objects

    NASA Astrophysics Data System (ADS)

    Hintz, Eric G.; Joner, Michael D.

    2016-01-01

    In Joner and Hintz (2015) they report on a standard star system for calibration of H-alpha and H-beta observations. This work was based on data obtained with the Dominion Astrophysical Observatory 1.2-m telescope. As part of the data acquisition for that project, a large number of emission line objects were also observed. We will report on the preliminary results for the emission line data set. This will include a comparison of equivalent width measurements of each line with the matching index. We will also examine the relation between the absorption line objects previously published and the emission line objects, along with a discussion of the transition point. Object types included are Be stars, high mass x-ray binaries, one low mass x-ray binary, Herbig Ae/Be stars, pre-main sequence stars, T Tauri stars, young stellar objects, and one BY Draconis star. Some of these objects come from Cygnus OB-2, NGC 659, NGC 663, NGC 869 and NGC 884.

  4. Hot beta particles in the lung: Results from dogs exposed to fission product radionuclides

    SciTech Connect

    Hahn, F.F.; Griffith, W.C.; Hobbs, C.H.

    1995-12-01

    The Chernobyl nuclear reactor accident resulted in the release of uranium dioxide fuel and fission product radionuclides into the environment with the fallout of respirable, highly radioactive particles that have been termed {open_quotes}hot beta particles.{close_quotes} There is concern that these hot beta particles (containing an average of 150-20,000 Bq/particle), when inhaled and deposited in the lung, may present an extraordinary hazard for the induction of lung cancer. We reviewed data from a group of studies in dogs exposed to different quantities of beta-emitting radionuclides with varied physical half-lives to determine if those that inhaled hot beta particles were at unusual risk for lung cancer. This analysis indicates that the average dose to the lung is adequate to predict biologic effects of lung cancer for inhaled beta-emitting radionuclides in the range of 5-50 Gy to the lung and with particle activities in the range of 0.10-50 Bq/particle.

  5. Direct Reading Particle Counters: Calibration Verification and Multiple Instrument Agreement via Bump Testing

    DOE PAGES

    Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.; Hollenbeck, Scott

    2015-01-27

    We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The methodmore » consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.« less

  6. Time-of-flight neutral particle analyzer and calibration.

    PubMed

    Harris, W S; Garate, E P; Heidbrink, W W; McWilliams, R; Roche, T; Trask, E; Zhang, Yang

    2008-10-01

    A time-of-flight diagnostic has been implemented on the Irvine field reversed configuration (IFRC) to obtain an energy distribution function from charge-exchanged neutral hydrogen. The diagnostic includes a 13 cm radius slotted disk rotating at 165 Hz in vacuum which chops the emitted neutrals at a rate of 26 kHz. In situ timing verification was performed with a dc xenon discharge lamp with an uncertainty less than 100 ns for a 38 micros chopping period. Energy calibration was accomplished with a singly ionized lithium source in the range of 300-1500 eV, achieving an average energy uncertainty, DeltaE/E, of 0.11. The diagnostic has measured neutrals in the range of 20-80 eV from the IFRC and the corresponding energy distribution function has been obtained.

  7. Time-of-flight neutral particle analyzer and calibration

    SciTech Connect

    Harris, W. S.; Garate, E. P.; Heidbrink, W. W.; McWilliams, R.; Roche, T.; Trask, E.; Zhang Yang

    2008-10-15

    A time-of-flight diagnostic has been implemented on the Irvine field reversed configuration (IFRC) to obtain an energy distribution function from charge-exchanged neutral hydrogen. The diagnostic includes a 13 cm radius slotted disk rotating at 165 Hz in vacuum which chops the emitted neutrals at a rate of 26 kHz. In situ timing verification was performed with a dc xenon discharge lamp with an uncertainty less than 100 ns for a 38 {mu}s chopping period. Energy calibration was accomplished with a singly ionized lithium source in the range of 300-1500 eV, achieving an average energy uncertainty, {delta}E/E, of 0.11. The diagnostic has measured neutrals in the range of 20-80 eV from the IFRC and the corresponding energy distribution function has been obtained.

  8. Cerenkov Counting Technique for Beta Particles: Advantages and Limitations.

    ERIC Educational Resources Information Center

    Rengan, K.

    1983-01-01

    Cerenkov counting is a useful technique for assaying medium/high energy beta emitters in aqueous solutions. Advantages of the technique include: (1) simple sample preparation; (2) being able to handle large volume of aqueous solution for counting; and (3) absence of chemical quenching. Cerenkov counting is also less expensive than other methods.…

  9. Absorption of Beta Particles in Different Materials: An Undergraduate Experiment

    ERIC Educational Resources Information Center

    La Rocca, Paola; Riggi, Francesco

    2009-01-01

    The absorption of beta rays from a radioactive source in different materials was investigated by the use of a simple setup based on a Geiger counter and a set of absorber sheets. The number of electrons traversing the material was measured as a function of its thickness. Detailed GEANT simulations were carried out to reproduce the obtained…

  10. Calibrating an updated smoothed particle hydrodynamics scheme within gcd+

    NASA Astrophysics Data System (ADS)

    Kawata, D.; Okamoto, T.; Gibson, B. K.; Barnes, D. J.; Cen, R.

    2013-01-01

    We adapt a modern scheme of smoothed particle hydrodynamics (SPH) to our tree N-body/SPH galactic chemodynamics code gcd+. The applied scheme includes implementations of the artificial viscosity switch and artificial thermal conductivity proposed by Morris & Monaghan, Rosswog & Price and Price to model discontinuities and Kelvin-Helmholtz instabilities more accurately. We first present hydrodynamics test simulations and contrast the results to runs undertaken without artificial viscosity switch or thermal conduction. In addition, we also explore the different levels of smoothing by adopting larger or smaller smoothing lengths, i.e. a larger or smaller number of neighbour particles, Nnb. We demonstrate that the new version of gcd+ is capable of modelling Kelvin-Helmholtz instabilities to a similar level as the mesh code, athena. From the Gresho vortex, point-like explosion and self-similar collapse tests, we conclude that setting the smoothing length to keep Nnb as high as ˜58 is preferable to adopting smaller smoothing lengths. We present our optimized parameter sets from the hydrodynamics tests.

  11. Automatic Calibration of a Semi-Distributed Hydrologic Model Using Particle Swarm Optimization

    NASA Astrophysics Data System (ADS)

    Bekele, E. G.; Nicklow, J. W.

    2005-12-01

    Hydrologic simulation models need to be calibrated and validated before using them for operational predictions. Spatially-distributed hydrologic models generally have a large number of parameters to capture the various physical characteristics of a hydrologic system. Manual calibration of such models is a very tedious and daunting task, and its success depends on the subjective assessment of a particular modeler, which includes knowledge of the basic approaches and interactions in the model. In order to alleviate these shortcomings, an automatic calibration model, which employs an evolutionary optimization technique known as Particle Swarm Optimizer (PSO) for parameter estimation, is developed. PSO is a heuristic search algorithm that is inspired by social behavior of bird flocking or fish schooling. The newly-developed calibration model is integrated to the U.S. Department of Agriculture's Soil and Water Assessment Tool (SWAT). SWAT is a physically-based, semi-distributed hydrologic model that was developed to predict the long term impacts of land management practices on water, sediment and agricultural chemical yields in large complex watersheds with varying soils, land use, and management conditions. SWAT was calibrated for streamflow and sediment concentration. The calibration process involves parameter specification, whereby sensitive model parameters are identified, and parameter estimation. In order to reduce the number of parameters to be calibrated, parameterization was performed. The methodology is applied to a demonstration watershed known as Big Creek, which is located in southern Illinois. Application results show the effectiveness of the approach and model predictions are significantly improved.

  12. The Nuclear and Particle Physics of Neutrinoless Double Beta Decay

    NASA Astrophysics Data System (ADS)

    Haxton, Wick

    2014-03-01

    Fortuitous properties of nuclei allow us to isolate and study the rare second-order weak process of double beta decay. In particular, the decay channel in which a final state of two electrons and no neutrinos is produced - neutrinoless double beta decay - provides our best test of lepton number conservation and the Majorana mass of the electron neutrino. I will describe the connections between this process and the charge conjugation properties of the neutrino, including the possibility that the presence of both Dirac and Majorana masses accounts for the anomalous scale of neutrino masses. The extraordinary progress made over the past two decades has prepared the way for next-generation experiments that will probe Majorana masses at levels where nonzero rates may be found, given what we now know about neutrino mass splittings. I will describe some of the heroic efforts underway to develop detectors of unprecedented size, radiopurity, depth, and thus sensitivity. Work supported by the Office of Science, US DOE.

  13. Direct detection of Tritium and Carbon-14 beta particles with GaAs photodiodes

    NASA Astrophysics Data System (ADS)

    Barnett, A. M.; Lees, J. E.; Bassford, D. J.

    2012-09-01

    New measurements are reported which show beta particles emitted from 3H and 14C sources being directly detected with GaAs mesa photodiodes without use of scintillators. Spectra accumulated with GaAs diodes which were originally developed for X-ray spectroscopy are presented which show that individual beta particles from these sources can be counted and the energy they deposit in the detector measured. Potential longer term applications of this technology as it is developed further and improved include space missions, autoradiography, monitoring tritium produced by fusion reactors and nuclear decommissioning.

  14. Development of a Cerenkov radiation sensor to detect low-energy beta-particles.

    PubMed

    Yoo, Wook Jae; Han, Ki-Tek; Shin, Sang Hun; Seo, Jeong Ki; Jeon, Dayeong; Lee, Bongsoo

    2013-11-01

    We fabricated a novel fiber-optic Cerenkov radiation sensor using a Cerenkov radiator for measuring beta-particles. Instead of employing a scintillator, transparent liquids having various refractive indices were used as a Cerenkov radiator to serve as a sensing material. The experimental results showed that the amount of Cerenkov radiation due to the interaction with beta-particles increased as the refractive index of the Cerenkov radiator was increased as a results of a decrease of the Cerenkov threshold energy for electrons.

  15. Particle generators for the calibration and testing of narcotic and explosive vapor/particle detection systems

    NASA Astrophysics Data System (ADS)

    Davies, John P.; Hallowell, Susan F.; Hoglund, David E.

    1994-03-01

    A review of data on narcotics and explosives particulates is presented. Methods to generate particles of narcotics and explosives will be discussed with respect to resulting particle size distribution and mass output. The application of these standards to the testing of narcotic and explosive particle detection systems will be addressed.

  16. Reversal of particle flux in collisional-finite beta tokamak discharges

    SciTech Connect

    Ma, J.; Wang, G.; Weiland, J.; Rafiq, T.; Kritz, A. H.

    2015-01-15

    The mixed gradient method [Zhong et al. Phys. Rev. Lett. 111, 265001 (2013)] is adopted and effects of collisions and finite beta are included in the Weiland 9-equation fluid model. The particle flux and particle pinch, obtained using the Weiland anomalous transport fluid model, are compared with Tore Supra experimental results. Particle transport is also studied using predictive simulation data for an experimental advanced superconducting tokamak discharge in which neutral beam heating is utilized. The effects of collisions on particle transport are studied by turning collisions on and off in the Weiland model. It is found that the particle pinch region is related to the mode structure. The particle pinch region coincides with the region where the strong ballooning modes are present due to large gradients. The general properties of the fluid model are examined by finding regions where collisions can enhance the particle pinch.

  17. Peculiarities of both light and beta-particles scattering by ultrathin diamond-like semiconductor film.

    PubMed

    Rumyantsev, Vladimir V; Shtaerman, Esfir Y

    2008-02-01

    Peculiarities of scattering of TM-polarized light wave by a diamond-like crystalline nano-layer are studied. They are due to specific dispersion of n-phonon polaritons localized in the layer. The IR polaritons discussed here (relating to diamond and Si crystals which are nonpolar materials) will only appear if some of the vibration modes become polar, e.g., due to the presence of the surface. As a result of mixing of g- and u-modes of ion oscillations along the (111)-direction in the near-surface layer, it is possible to observe additional (with respect to bulk) scattering of coherent electromagnetic waves of the Stokes and anti-Stokes frequencies. beta-particles can be utilized as an independent tool of study of new semiconductors, in particular thin diamond films. The effect associated with response of a quasi-two-dimensional diamond-like layer to the moving electron field is considered. beta-particle field induces phonon excitation modes to arise in the material. Coupled with the beta-particle electromagnetic modes they generate polaritons. Spectral density of the radiation intensity of the flashed phonon polaritons has been estimated as a function of the layer thickness as well as of the scattering angle and the beta-particle velocity.

  18. Applications of Beta Particle Detection for Synthesis and Usage of Radiotracers Developed for Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Dooraghi, Alex Abreu

    Positron Emission Tomography (PET) is a noninvasive molecular imaging tool that requires the use of a radioactive compound or radiotracer which targets a molecular pathway of interest. We have developed and employed three beta particle radiation detection systems to advance PET. Specifically, the goals of these systems are to: 1. Automate dispensing of solutions containing a positron emitting isotope. 2. Monitor radioactivity on-chip during synthesis of a positron emitting radiotracer. 3. Assay cellular uptake on-chip of a positron emitting radiotracer. Automated protocols for measuring and dispensing solutions containing radioisotopes are essential not only for providing an optimum environment for radiation workers, but also to ensure a quantitatively accurate workflow. For the first project, we describe the development and performance of a system for automated radioactivity distribution of beta particle emitting radioisotopes such as fluorine-18 (F-18). Key to the system is a radiation detector in-line with a peristaltic pump. The system demonstrates volume accuracy within 5 % for volumes of 20 muL or greater. When considering volumes of 20 muL or greater, delivered radioactivity is in agreement with the requested radioactivity as measured with the dose calibrator. The integration of the detector and pump leads to a flexible system that can accurately dispense solutions containing F-18 in radioactivity concentrations directly produced from a cyclotron (~ 0.1-1 mCi/muL), to low activity concentrations intended for preclinical mouse scans (~ 1-10 muCi/muL), and anywhere in between. Electrowetting on dielectric (EWOD) is an attractive microfluidic platform for batch synthesis of PET radiotracers. Visualization of radioisotopes on-chip is critical for synthesis optimization and technological development. For the second project, we describe the development and performance of a Cerenkov/real-time imaging system for PET radiotracer synthesis on EWOD. We also investigate

  19. The Energetic Particle Detector (EPD) for Solar Orbiter - Sensor Status and Calibration

    NASA Astrophysics Data System (ADS)

    Wimmer-Schweingruber, R. F.; Rodriguez-Pacheco, J.; Mason, G. M.; Martin-Garcia, C.; Prieto, M.; Böttcher, S. I.; Kulkarni, S. R.; Panitzsch, L.; Sanchez, S.; Ho, G. C.; Kohler, J.; Gomez-Herrero, R.; Blanco, J. J.

    2014-12-01

    Solar Orbiter will solve the puzzle how the Sun creates and controls the heliosphere, the giant plasma bubble which forms as a result of the interaction of the solar wind with the local interstellar medium. Energetic particles are part of this puzzle and help understand the various driving forces and energy release processes in the solar corona. The Energetic Particle Detector (EPD) will determine how the Sun energizes particles to very high energies and sometimes fills the heliosphere with particle radiation. It consists of a suite of sensors which will measure protons (electrons) from 3 (2) keV up to 100 (20) MeV and ions from few tens of keV/nuc to 200 MeV/nuc. We will discuss the scientific aims of EPD as well as the current status and calibration of the EPD sensor (STEP, EPT, SIS, HET).

  20. Near-infrared turbidity of beta-FeOOH particle suspensions

    SciTech Connect

    Berdahl, P.; Espinoza, L.H.; Littlejohn, D.; Lucas, D.; Perry, D.L.

    1999-09-01

    Near-infrared transmission spectroscopy can be complicated by the light scattering from heterogeneous materials. To examine an evolving system exhibiting such light scattering, transmission spectra are obtained during the hydrolysis of iron chloride solutions. At first, the resulting turbid suspension of cigar-shaped beta-FeOOH particles exhibits single-particle scattering, including a Rayleigh regime (attenuation proportional to the fourth power of the wavenumber). At later times, the scattering increases strongly as the particles aggregate, and becomes proportional to the wavenumber squared, consistent with scattering models which interpret the structure of aggregates in terms of a fractal dimension roughly equal to 2.

  1. Improved methods of measurement and analysis of conversion electron and beta-particle spectra

    PubMed

    Dragoun; Spalek; Rysavy; Kovalik; Yakushev; Brabec; Frana; Venos

    2000-03-01

    A general statistical test of the stability of measurement conditions was demonstrated on the beta-spectra of 241Pu cumulated during four years. The alpha- and gamma-ray spectroscopy indicated stability of the 241Pu source. Monte Carlo modelling of individual collision events clarified the role of electron scattering and energy losses within a radioactive source down to energies of several hundreds of eV. The impact ionization by beta-particles of carbon and oxygen atoms in a surface contamination layer on the 241Pu and 63Ni sources was observed. PMID:10724379

  2. Calibration and demonstration of a condensation nuclei counting system for airborne measurements of aircraft exhausted particles

    NASA Astrophysics Data System (ADS)

    Cofer, Wesley R.; Anderson, Bruce E.; Winstead, Edward L.; Bagwell, Donald R.

    A system of multiple continuous-flow condensation nuclei counters (CNC) was assembled, calibrated, and demonstrated on a NASA T-39 Sabreliner jet aircraft. The mission was to penetrate the exhaust plumes and/or contrails of other subsonic jet aircraft and determine the concentrations of submicrometer diameter aerosol particles. Mission criteria required rapid response measurements ( ˜ 1 s) at aircraft cruise altitudes (9-12 km). The CNC sampling system was optimized to operate at 160 Torr. Aerosol samples were acquired through an externally mounted probe. Installed downstream of the probe was a critical flow orifice that provided sample to the CNC system. The orifice not only controlled volumetric flow rate, but also dampened probe pressure/flow oscillations encountered in the turbulent aircraft-wake vortex environment. Laboratory calibrations with NaCl particles under representative conditions are reported that indicate small amounts of particle loss and a maximum measurement efficiency of ˜ 75% for particles with diameters ranging from ⩾ 0.01- ⩽ 0.18 μm Data from exhaust/contrail samplings of a NASA B757 and DC-8 at cruise altitude are discussed. Data include exhaust/contrail measurements made during periods in which the B757 port jet engine burned low-sulfur fuel while the starboard engine simultaneously burned specially prepared high-sulfur fuel. The data discussed highlight the CNC systems performance, and introduce new observations pertinent to the behavior of sulfur in aircraft exhaust aerosol chemistry.

  3. Gyrokinetic study of the role of {beta} on electron particle transport in tokamaks

    SciTech Connect

    Hein, T.; Angioni, C.; Fable, E.; Candy, J.

    2010-10-15

    Electromagnetic effects on the radial transport of electrons in the core of tokamak plasmas are studied by means of linear and nonlinear gyrokinetic simulations with the code GYRO[J. Candy and R. E. Waltz, J. Comput. Phys. 186, 545 (2003)] and by an analytical derivation. The impact of a finite {beta}, that is, a finite ratio of the plasma pressure to the magnetic pressure, is considered on the fluctuations of the magnetic field through Ampere's law, as well as on the geometrical modification of the vertical drift produced by the Shafranov shift in the magnetic equilibrium, which, for realistic descriptions, has to be included in both electrostatic and electromagnetic modeling. The condition of turbulent particle flux at the null, which allows the determination of stationary logarithmic density gradients when neoclassical transport and particle sources are negligible, is investigated for increasing values of {beta}, in regimes of ion temperature gradient and trapped electron mode turbulence. The loss of adiabaticity of passing electrons produced by fluctuations in the magnetic vector potential produces an outward convection. When the magnetic equilibrium geometry is kept fixed, this induces a strong reduction of the stationary logarithmic density gradient with increasing {beta}. This effect is partly compensated by the geometrical effect on the vertical drift. This compensation effect, however, is significantly weaker in nonlinear simulations as compared to quasilinear calculations. A detailed comparison between quasilinear and nonlinear results reveals that the predicted value of the logarithmic density gradient is highly sensitive on the assumptions on the wave number spectrum applied in the quasilinear model. The qualitative consistency of the theoretical predictions with the experimental results obtained so far on the dependence of density peaking on {beta} is discussed by considering the additional impact, with increasing {beta}, of a particle source delivered

  4. Beta dependence of electron heating in decaying whistler turbulence: Particle-in-cell simulations

    SciTech Connect

    Saito, S.; Peter Gary, S.

    2012-01-15

    Two-dimensional particle-in-cell simulations have been carried out to study electron beta dependence of decaying whistler turbulence and electron heating in a homogeneous, collisionless magnetized plasma. Initially, applied whistler fluctuations at relatively long wavelengths cascade their energy into shorter wavelengths. This cascade leads to whistler turbulence with anisotropic wavenumber spectra which are broader in directions perpendicular to the background magnetic field than in the parallel direction. Comparing the development of whistler turbulence at different electron beta values, it is found that both the wavenumber spectrum anisotropy and electron heating anisotropy decrease with increasing electron beta. This indicates that higher electron beta reduces the perpendicular energy cascade of whistler turbulence. Fluctuation energy dissipation by electron Landau damping responsible for the electron parallel heating becomes weaker at higher electron beta, which leads to more isotropic heating. It suggests that electron kinetic processes are important in determining the properties of whistler turbulence. This kinetic property is applied to discuss the generation of suprathermal strahl electron distributions in the solar wind.

  5. Calibrations for Charged Particle Tracking with the GlueX Detector

    NASA Astrophysics Data System (ADS)

    Staib, Michael; GlueX Collaboration

    2015-10-01

    Two gas detectors comprise the tracking system for the GlueX experiment, the Central Drift Chamber (CDC) and the Forward Drift Chamber (FDC). The CDC is a cylindrical straw-tube detector covering polar angles between 6° and 168°, delivering spatial resolution of ~150 μm. The FDC is a Cathode Strip Chamber consisting of four packages, each with six alternating layers of anode wires and cathode strips. The FDC is designed to track forward-going charged particles with polar angles between 1° and 20° with a spatial resolution of ~200 μm. Both tracking detectors record timing information and energy loss measurements useful for particle identification. During Fall 2014 and Spring 2015, the first photon beam was delivered on target for commissioning of the GlueX detector in Hall-D at Jefferson Lab. These data are currently being used in a large effort to calibrate the individual detector subsystems to achieve design performance. Methods and results for calibrations of each of the tracking detectors are presented. Techniques for alignment of the tracking system using a combination of cosmic rays and beam data is discussed. Finally, some early results of physics measurements including charged final-state particles are presented. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under Contract DE-AC05-06OR23177.

  6. Monte Carlo simulation of a beta particle detector for food samples.

    PubMed

    Sato, Y; Takahashi, H; Yamada, T; Unno, Y; Yunoki, A

    2013-11-01

    The accident at the Fukushima Daiichi Nuclear Power Plant in March 2011 released radionuclides into the environment. There is concern that (90)Sr will be concentrated in seafood. To measure the activities of (90)Sr in a short time without chemical processes, we have designed a new detector for measuring activity that obtains count rates using 10 layers of proportional counters that are separated by walls that absorb beta particles. Monte Carlo simulations were performed to confirm that its design is appropriate.

  7. Immunogenicity of recombinant human interferon beta interacting with particles of glass, metal, and polystyrene.

    PubMed

    Van Beers, Miranda M C; Gilli, Francesca; Schellekens, Huub; Randolph, Theodore W; Jiskoot, Wim

    2012-01-01

    Aggregates play a major role in the immunogenicity of recombinant human interferon beta (rhIFNβ), a protein used to treat multiple sclerosis. A possible cause of aggregation is interaction between therapeutic protein and surfaces encountered during processing, storage, and administration. Moreover, proteins may adsorb to particles shed from these surfaces. In this work, we studied the immunogenicity of recombinant human interferon beta-1a (rhIFNβ-1a) interacting with glass microparticles, stainless steel microparticles, and polystyrene nanoparticles. At physiological pH, rhIFNβ-1a readily adsorbed to the particles, while the degree of adsorption was influenced by the ionic strength of the phosphate buffer. Front-face fluorescence showed that the tertiary structure of rhIFNβ-1a slightly changed upon adsorption to glass. The interaction with stainless steel microparticles resulted in increased levels of aggregates in the free protein fraction. Furthermore, protein adsorbed to stainless steel microparticles was more difficult to desorb than protein adsorbed to glass. Incubation with stainless steel considerably enhanced the immunogenicity of rhIFNβ-1a in transgenic mice immune tolerant for human interferon beta. The protein fraction adsorbed on stainless steel particles was responsible for this. In conclusion, rhIFNβ-1a adsorbs to common hydrophilic surface materials, possibly increasing the immunogenicity of the protein.

  8. hydroPSO: A Versatile Particle Swarm Optimisation R Package for Calibration of Environmental Models

    NASA Astrophysics Data System (ADS)

    Zambrano-Bigiarini, M.; Rojas, R.

    2012-04-01

    Particle Swarm Optimisation (PSO) is a recent and powerful population-based stochastic optimisation technique inspired by social behaviour of bird flocking, which shares similarities with other evolutionary techniques such as Genetic Algorithms (GA). In PSO, however, each individual of the population, known as particle in PSO terminology, adjusts its flying trajectory on the multi-dimensional search-space according to its own experience (best-known personal position) and the one of its neighbours in the swarm (best-known local position). PSO has recently received a surge of attention given its flexibility, ease of programming, low memory and CPU requirements, and efficiency. Despite these advantages, PSO may still get trapped into sub-optimal solutions, suffer from swarm explosion or premature convergence. Thus, the development of enhancements to the "canonical" PSO is an active area of research. To date, several modifications to the canonical PSO have been proposed in the literature, resulting into a large and dispersed collection of codes and algorithms which might well be used for similar if not identical purposes. In this work we present hydroPSO, a platform-independent R package implementing several enhancements to the canonical PSO that we consider of utmost importance to bring this technique to the attention of a broader community of scientists and practitioners. hydroPSO is model-independent, allowing the user to interface any model code with the calibration engine without having to invest considerable effort in customizing PSO to a new calibration problem. Some of the controlling options to fine-tune hydroPSO are: four alternative topologies, several types of inertia weight, time-variant acceleration coefficients, time-variant maximum velocity, regrouping of particles when premature convergence is detected, different types of boundary conditions and many others. Additionally, hydroPSO implements recent PSO variants such as: Improved Particle Swarm

  9. An application of Brookhaven National Laboratory`s hot particle methodology for determining the most effective beta particle energy in causing skin ulcers

    SciTech Connect

    Schaefer, C.

    1994-11-01

    The purpose of this project was to compare the effectiveness of hot particles with different energy betas in producing ulcers on skin. The sources were man-made hot particles similar in size and activity to those found in the commercial nuclear power industry. Four different particle types were used. These were thulium (Tm-170) with a 0.97 MeV maximum energy beta, ytterbium (Yb-175) with a maximum beta energy of 0.47 MeV, scandium (Sc-46) with a 0.36 MeV beta, which was used as a surrogate for cobalt-60 (0.31 MeV beta) and uranium (in the carbide form) with an average maximum beta energy of about 2.5 MeV. Since higher energy beta particles penetrate further in skin, they will affect a higher number and different populations of target cells. The experiments were designed as threshold studies such that the dose needed to produce ulcers ten percent of the time (ED 10%) for each particle type could be compared against each other.

  10. Gain Calibration of a Beta/Gamma Coincidence Spectrometer for Automated Radioxenon Analysis

    SciTech Connect

    Reeder, Paul L.; Bowyer, Ted W.; McIntyre, Justin I.; Pitts, W. K.; Ringbom, Anders; Johansson, Cecilia

    2004-04-01

    Abstract Detection and measurement of atmospheric radioxenon is an important component of international monitoring systems for nuclear weapons testing. Monitoring stations separate xenon from air and perform isotopic analysis of the radioxenon. In one such radioxenon measurement scheme, the isotopes of interest are identified by coincident spectroscopy of electrons and photons in a bg coincidence spectrometer (BGCS). The b spectrometer is a plastic scintillator, produced as a cylindrical cell containing the separated xenon sample. This cell is surrounded by the NaI(Tl) g spectrometer. We report here the development of a calibration process for the BGCS suitable for use in remote sampling systems. This procedure is based upon g-ray Compton scattering, resulting in a true coincident signal in both detectors, generation of electrons over a wide energy range that matches the energy distribution of electrons from radioxenon decay, and a relative insensitivity to source location. Besides gain calibration, this procedure determines the resolution of the b detector as a function of energy.

  11. Particle sizing calibration with refractive index correction for light scattering optical particle counters and impacts upon PCASP and CDP data collected during the Fennec campaign

    NASA Astrophysics Data System (ADS)

    Rosenberg, P. D.; Dean, A. R.; Williams, P. I.; Dorsey, J. R.; Minikin, A.; Pickering, M. A.; Petzold, A.

    2012-05-01

    Optical particle counters (OPCs) are used regularly for atmospheric research, measuring particle scattering cross sections to generate particle size distribution histograms. This manuscript presents two methods for calibrating OPCs with case studies based on a Passive Cavity Aerosol Spectrometer Probe (PCASP) and a Cloud Droplet Probe (CDP), both of which are operated on the Facility for Airborne Atmospheric Measurements BAe-146 research aircraft. A probability density function based method is provided for modification of the OPC bin boundaries when the scattering properties of measured particles are different to those of the calibration particles due to differences in refractive index or shape. This method provides mean diameters and widths for OPC bins based upon Mie-Lorenz theory or any other particle scattering theory, without the need for smoothing, despite the highly nonlinear and non-monotonic relationship between particle size and scattering cross section. By calibrating an OPC in terms of its scattering cross section the optical properties correction can be applied with minimal information loss, and performing correction in this manner provides traceable and transparent uncertainty propagation throughout the whole process. Analysis of multiple calibrations has shown that for the PCASP the bin centres differ by up to 30% from the manufacturer's nominal values and can change by up to approximately 20% when routine maintenance is performed. The CDP has been found to be less sensitive than the manufacturer's specification with differences in sizing of between 1.6 ± 0.8 μm and 4.7 ± 1.8 μm for one flight. Over the course of the Fennec project in the Sahara the variability of calibration was less than the calibration uncertainty in 6 out of 7 calibrations performed. As would be expected from Mie-Lorenz theory, the impact of the refractive index corrections has been found to be largest for absorbing materials and the impact on Saharan dust measurements made

  12. A Beta-Particle Hodoscope Constructed Using Scintillating Optical Fibers and Position Sensitive Photomultiplier Tubes

    SciTech Connect

    Orrell, John L.; Aalseth, Craig E.; Day, Anthony R.; Fast, Jim; Hossbach, Todd W.; Lidey, Lance S.; Ripplinger, Mike D.; Schrom, Brian T.

    2006-09-19

    A hodoscopic detector was constructed using a position-sensitive plastic scintillator active area to determine the location of beta-active micron-sized particulates on air filters. The ability to locate beta active particulates on airsample filters is a tool for environmental monitoring of anthropogenic production of radioactive material. A robust, field-deployable instrument can provide localization of radioactive particulate with position resolution of a few millimeters. The detector employs a novel configuration of scintillating plastic elements usually employed at much higher charged particle energies. A filter is placed on this element for assay. The detector is intended to be sensitive to activity greater than 1 Bq. The physical design, position reconstruction method, and expected detector sensitivity are reported.

  13. Solar Flare Track Exposure Ages in Regolith Particles: A Calibration for Transmission Electron Microscope Measurements

    NASA Technical Reports Server (NTRS)

    Berger, Eve L.; Keller, Lindsay P.

    2015-01-01

    Mineral grains in lunar and asteroidal regolith samples provide a unique record of their interaction with the space environment. Space weathering effects result from multiple processes including: exposure to the solar wind, which results in ion damage and implantation effects that are preserved in the rims of grains (typically the outermost 100 nm); cosmic ray and solar flare activity, which result in track formation; and impact processes that result in the accumulation of vapor-deposited elements, impact melts and adhering grains on particle surfaces. Determining the rate at which these effects accumulate in the grains during their space exposure is critical to studies of the surface evolution of airless bodies. Solar flare energetic particles (mainly Fe-group nuclei) have a penetration depth of a few millimeters and leave a trail of ionization damage in insulating materials that is readily observable by transmission electron microscope (TEM) imaging. The density of solar flare particle tracks is used to infer the length of time an object was at or near the regolith surface (i.e., its exposure age). Track measurements by TEM methods are routine, yet track production rate calibrations have only been determined using chemical etching techniques [e.g., 1, and references therein]. We used focused ion beam-scanning electron microscope (FIB-SEM) sample preparation techniques combined with TEM imaging to determine the track density/exposure age relations for lunar rock 64455. The 64455 sample was used earlier by [2] to determine a track production rate by chemical etching of tracks in anorthite. Here, we show that combined FIB/TEM techniques provide a more accurate determination of a track production rate and also allow us to extend the calibration to solar flare tracks in olivine.

  14. Gallium Arsenide detectors for X-ray and electron (beta particle) spectroscopy

    NASA Astrophysics Data System (ADS)

    Lioliou, G.; Barnett, A. M.

    2016-11-01

    Results characterizing GaAs p+-i-n+ mesa photodiodes with a 10 μm i layer for their spectral response under illumination of X-rays and beta particles are presented. A total of 22 devices, having diameters of 200 μm and 400 μm, were electrically characterized at room temperature. All devices showed comparable characteristics with a measured leakage current ranging from 4 nA/cm2 to 67 nA/cm2 at an internal electric field of 50 kV/cm. Their unintentionally doped i layers were found to be almost fully depleted at 0 V due to their low doping density. 55Fe X-ray spectra were obtained using one 200 μm diameter device and one 400 μm diameter device. The best energy resolution (FWHM at 5.9 keV) achieved was 625 eV using the 200 μm and 740 eV using the 400 μm diameter device, respectively. Noise analysis showed that the limiting factor for the energy resolution of the system was the dielectric noise; if this noise was eliminated by better design of the front end of the readout electronics, the achievable resolution would be 250 eV. 63Ni beta particle spectra obtained using the 200 μm diameter device showed the potential utility of these detectors for electron and beta particle detection. The development of semiconductor electron spectrometers is important particularly for space plasma physics; such devices may find use in future space missions to study the plasma environment of Jupiter and Europa and the predicted electron impact excitation of water vapor plumes from Europa hypothesized as a result of recent Hubble Space Telescope (HST) UV observations.

  15. Vaccinia virus recombinants expressing an 11-kilodalton beta-galactosidase fusion protein incorporate active beta-galactosidase in virus particles.

    PubMed

    Huang, C; Samsonoff, W A; Grzelecki, A

    1988-10-01

    Recombinant plasmids in which vaccinia virus transcriptional regulatory sequences were fused to the Escherichia coli lacZ gene were constructed for insertion of the lacZ gene into the vaccinia virus genome. beta-Galactosidase (beta-gal) was found in some purified recombinant vaccinia virions. By enzyme activity, sodium dodecyl sulfate-polyacrylamide gel electrophoresis, and microscopic techniques, the evidence suggested that beta-gal accounted for 5% of the total protein in the virion. These recombinant viruses were constructed so that a portion of the coding sequences of a late vaccinia virus structural polypeptide was fused to the amino terminus of beta-gal to produce the fusion protein. Removal of the coding sequences resulted in the complete loss of beta-gal activity. This demonstrated that a vaccinia virus DNA segment from a late structural gene is responsible for the incorporation of beta-gal into the virion.

  16. A low-noise current-sensitive amplifier-discriminator system for beta particle counting.

    PubMed

    Sephton, J P; Johansson, L C; Williams, J M

    2008-01-01

    NPL has developed a low-noise current amplifier/discriminator system for radionuclides that emit low-energy electrons and X-rays. The new beta amplifier is based on the low-noise Amptek A-250 operational amplifier. The design has been configured for optimum signal to noise ratio. The new amplifier is described and results obtained using primarily electron-capture decaying radionuclides are presented. The new amplifier gives rise to higher particle detection efficiency than the previously used Atomic Energy of Canada Limited-designed amplifier. This is shown by measurements of (54)Mn and (65)Zn. The counting plateaux are significantly longer and have reduced gradients.

  17. A probabilistic respiratory tract dosimetry model with application to beta-particle and photon emitters

    NASA Astrophysics Data System (ADS)

    Farfan, Eduardo Balderrama

    2002-01-01

    Predicting equivalent dose in the human respiratory tract is significant in the assessment of health risks associated with the inhalation of radioactive aerosols. A complete respiratory tract methodology based on the International Commission on Radiological Protection Publication 66 model was used in this research project for beta-particle and photon emitters. The conventional methodology has been to use standard values (from Reference Man) for parameters to obtain a single dose value. However, the methods used in the current study allow lung dose values to be determined as probability distributions to reflect the spread or variability in doses. To implement the methodology, a computer code, LUDUC, has been modified to include inhalation scenarios of beta-particle and photon emitters. For beta particles, a new methodology was implemented into Monte Carlo simulations to determine absorbed fractions in target tissues within the thoracic region of the respiratory tract. For photons, a new mathematical phantom of extrathoracic and thoracic regions was created based on previous studies to determine specific absorbed fractions in several tissues and organs of the human body due to inhalation of radioactive materials. The application of the methodology and developed data will be helpful in dose reconstruction and prediction efforts concerning the inhalation of short-lived radionuclides or radionuclides of Inhalation Class S. The resulting dose distributions follow a lognormal distribution shape for all scenarios examined. Applying the probabilistic computer code LUDUC to inhalation of strontium and yttrium aerosols has shown several trends, which could also be valid for many S radionuclide compounds that are beta-particle emitters. The equivalent doses are, in general, found to follow lognormal distributions. Therefore, these distributions can be described by geometric means and geometric standard deviations. Furthermore, a mathematical phantom of the extrathoracic and

  18. The Alpha Particle X-Ray Spectrometer (APXS): Results from Gusev Crater and Calibration Report

    NASA Technical Reports Server (NTRS)

    Gellert, R.; Rieder, R.; Brueckner, J.; Clark, B.; Dreibus, G.; Klingelhoefer, G.; Lugmair, G.; Ming, D.; Waenke, H.; Yen, A.; Zipfel, J.; Squyres, S.

    2006-01-01

    The chemical composition of rocks and soils on Mars analyzed during the Mars Exploration Rover Spirit Mission was determined by X-ray analyses with the Alpha Particle X-Ray Spectrometer (APXS). Details of the data analysis method and the instrument calibration are presented. Measurements performed on Mars to address geometry effects and background contributions are shown. Cross calibration measurements among several instrument sensors and sources are discussed. An unintentional swap of the two flight instruments is evaluated. New concentration data acquired during the first 470 sols of rover Spirit in Gusev Crater are presented. There are two geological regions, the Gusev plains and the Columbia Hills. The plains contain soils that are very similar to previous landing sites on Mars. A meteoritic component in the soil is identified. Rocks in the plains revealed thin weathering rinds. The underlying abraded rock was classified as primitive basalt. One of these rocks contained significant Br that is probably associated with vein-filling material of different composition. One of the trenches showed large subsurface enrichments of Mg, S, and Br. Disturbed soils and rocks in the Columbia Hills revealed different elemental compositions. These rocks are significantly weathered and enriched in mobile elements, such as P, S, Cl, or Br. Even abraded rock surfaces have high Br concentrations. Thus, in contrast to the rocks and soils in the Gusev Plains, the Columbia Hills material shows more significant evidence of ancient aqueous alteration.

  19. Heat shock protein-90-beta facilitates enterovirus 71 viral particles assembly

    SciTech Connect

    Wang, Robert Y.L.; Kuo, Rei-Lin; Ma, Wei-Chieh; Huang, Hsing-I; Yu, Jau-Song; Yen, Sih-Min; Huang, Chi-Ruei; Shih, Shin-Ru

    2013-09-01

    Molecular chaperones are reported to be crucial for virus propagation, but are not yet addressed in Human Enterovirus 71 (EV71). Here we describe the specific association of heat shock protein-90-beta (Hsp90β), but not alpha form (Hsp90α), with EV71 viral particles by the co-purification with virions using sucrose density gradient ultracentrifugation, and by the colocalization with viral particles, as assessed by immunogold electron microscopy. The reduction of the Hsp90β protein using RNA interference decreased the correct assembly of viral particles, without affecting EV71 replication levels. Tracking ectopically expressed Hsp90β protein associated with EV71 virions revealed that Hsp90β protein was transmitted to new host cells through its direct association with infectious viral particles. Our findings suggest a new antiviral strategy in which extracellular Hsp90β protein is targeted to decrease the infectivity of EV71 and other enteroviruses, without affecting the broader functions of this constitutively expressed molecular chaperone. - Highlights: • Hsp90β is associated with EV71 virion and is secreted with the release virus. • Hsp90β effects on the correct assembly of viral particles. • Viral titer of cultured medium was reduced in the presence of geldanamycin. • Viral titer was also reduced when Hsp90β was suppressed by siRNA treatment. • The extracellular Hsp90β was also observed in other RNA viruses-infected cells.

  20. Quasilinear wave-particle scattering rate in high-beta turbulent collisionless plasmas

    NASA Astrophysics Data System (ADS)

    Santos de Lima, Reinaldo; Yan, Huirong; Lazarian, Alex; de Gouveia Dal Pino, Elisabete

    2015-08-01

    Collisionless or weakly collisional plasmas, like the plasma of the intracluster medium of galaxies, are subject to electromagnetic instabilities driven by temperature anisotropy, which naturally arise in the presence of turbulence. These instabilities produce anomalous collisionality via wave-particle scattering, then reducing the mean-free-path of the particles by several orders of magnitude. This reduction affects directly the transport properties of the plasma and makes its large scale dynamics to behave similar to collisional MHD. In particular, it allows the turbulence to amplify the magnetic fields via the small-scale dynamo. Using the quasilinear theory, we calculate the scattering rate of ions due to the kinetic instabilities ion-cyclotron, mirror, and firehose. Using these results we estimate the average scattering rate of ions consistent with data cubes of high-beta MHD turbulence which represent the intracluster medium.

  1. Pareto optimal calibration of highly nonlinear reactive transport groundwater models using particle swarm optimization

    NASA Astrophysics Data System (ADS)

    Siade, A. J.; Prommer, H.; Welter, D.

    2014-12-01

    Groundwater management and remediation requires the implementation of numerical models in order to evaluate the potential anthropogenic impacts on aquifer systems. In many situations, the numerical model must, not only be able to simulate groundwater flow and transport, but also geochemical and biological processes. Each process being simulated carries with it a set of parameters that must be identified, along with differing potential sources of model-structure error. Various data types are often collected in the field and then used to calibrate the numerical model; however, these data types can represent very different processes and can subsequently be sensitive to the model parameters in extremely complex ways. Therefore, developing an appropriate weighting strategy to address the contributions of each data type to the overall least-squares objective function is not straightforward. This is further compounded by the presence of potential sources of model-structure errors that manifest themselves differently for each observation data type. Finally, reactive transport models are highly nonlinear, which can lead to convergence failure for algorithms operating on the assumption of local linearity. In this study, we propose a variation of the popular, particle swarm optimization algorithm to address trade-offs associated with the calibration of one data type over another. This method removes the need to specify weights between observation groups and instead, produces a multi-dimensional Pareto front that illustrates the trade-offs between data types. We use the PEST++ run manager, along with the standard PEST input/output structure, to implement parallel programming across multiple desktop computers using TCP/IP communications. This allows for very large swarms of particles without the need of a supercomputing facility. The method was applied to a case study in which modeling was used to gain insight into the mobilization of arsenic at a deepwell injection site

  2. Does Your Optical Particle Counter Measure What You Think it Does? Calibration and Refractive Index Correction Methods.

    NASA Astrophysics Data System (ADS)

    Rosenberg, Phil; Dean, Angela; Williams, Paul; Dorsey, James; Minikin, Andreas; Pickering, Martyn; Petzold, Andreas

    2013-04-01

    Optical Particle Counters (OPCs) are the de-facto standard for in-situ measurements of airborne aerosol size distributions and small cloud particles over a wide size range. This is particularly the case on airborne platforms where fast response is important. OPCs measure scattered light from individual particles and generally bin particles according to the measured peak amount of light scattered (the OPC's response). Most manufacturers provide a table along with their instrument which indicates the particle diameters which represent the edges of each bin. It is important to correct the particle size reported by OPCs for the refractive index of the particles being measured, which is often not the same as for those used during calibration. However, the OPC's response is not a monotonic function of particle diameter and obvious problems occur when refractive index corrections are attempted, but multiple diameters correspond to the same OPC response. Here we recommend that OPCs are calibrated in terms of particle scattering cross section as this is a monotonic (usually linear) function of an OPC's response. We present a method for converting a bin's boundaries in terms of scattering cross section into a bin centre and bin width in terms of diameter for any aerosol species for which the scattering properties are known. The relationship between diameter and scattering cross section can be arbitrarily complex and does not need to be monotonic; it can be based on Mie-Lorenz theory or any other scattering theory. Software has been provided on the Sourceforge open source repository for scientific users to implement such methods in their own measurement and calibration routines. As a case study data is presented showing data from Passive Cavity Aerosol Spectrometer Probe (PCASP) and a Cloud Droplet Probe (CDP) calibrated using polystyrene latex spheres and glass beads before being deployed as part of the Fennec project to measure airborne dust in the inaccessible regions of

  3. Interaction of high-energy trapped particles with ballooning modes in a tokamak with a high-. beta. plasma

    SciTech Connect

    Mikhailovskii, A. B.; Novakovaskii, S. V.; Smolyakov, A. I.

    1988-12-01

    A theory is derived for the interaction of high-energy trapped particleswith ballooning modes in a tokamak with a high-..beta.. plasma. A dispersionrelation is derived to describe the ballooning modes in the presence ofsuch particles; the effects of the high plasma ..beta.. are taken into account.The stability boundary for ballooning modes with zero and finite frequenciesis studied. The effects of finite bananas on the stability of ballooningmodes with zero frequencies are determined.

  4. Betabox: a beta particle imaging system based on a position sensitive avalanche photodiode

    NASA Astrophysics Data System (ADS)

    Dooraghi, A. A.; Vu, N. T.; Silverman, R. W.; Farrell, R.; Shah, K. S.; Wang, J.; Heath, J. R.; Chatziioannou, A. F.

    2013-06-01

    A beta camera has been developed that allows planar imaging of the spatial and temporal distribution of beta particles using a 14 × 14 mm2 position sensitive avalanche photodiode (PSAPD). This camera system, which we call Betabox, can be directly coupled to microfluidic chips designed for cell incubation or other biological applications. Betabox allows for imaging the cellular uptake of molecular imaging probes labeled with charged particle emitters such as 18F inside these chips. In this work, we investigate the quantitative imaging capabilities of Betabox for 18F beta particles, in terms of background rate, efficiency, spatial resolution, and count rate. Measurements of background and spatial resolution are considered both at room temperature (21 °C ± 1 °C) and at an elevated operating temperature (37 °C ± 1 °C), as is often required for biological assays. The background rate measured with a 4 keV energy cutoff is below 2 cph mm-2 at both 21 and 37 °C. The absolute efficiency of Betabox for the detection of 18F positron sources in contact with a PSAPD with the surface passivated from ambient light and damage is 46% ± 1%. The lower detection limit is estimated using the Rose Criterion to be 0.2 cps mm-2 for 1 min acquisitions and a 62 × 62 µm2 pixel size. The upper detection limit is approximately 21 000 cps. The spatial resolution at both 21 and 37 °C ranges from 0.4 mm FWHM at the center of the field of view (FOV), and degrades to 1 mm at a distance of 5 mm away from center yielding a useful FOV of approximately 10 × 10 mm2. We also investigate the effects on spatial resolution and sensitivity that result from the use of a polymer based microfluidic chip. For these studies we place varying layers of low-density polyethylene (LDPE) between the detector and the source and find that the spatial resolution degrades by ˜180 µm for every 100 µm of LDPE film. Sensitivity is reduced by half with the inclusion of ˜200 µm of additional LDPE film. Lastly

  5. Betabox: a beta particle imaging system based on a position sensitive avalanche photodiode

    PubMed Central

    Dooraghi, AA; Vu, NT; Silverman, RW; Farrell, R; Shah, KS; Wang, J; Heath, JR; Chatziioannou, AF

    2013-01-01

    A beta camera has been developed that allows planar imaging of the spatial and temporal distribution of beta particles using a 14 × 14 mm2 position sensitive avalanche photodiode (PSAPD). This camera system, which we call Betabox, can be directly coupled to microfluidic chips designed for cell incubation or other biological applications. Betabox allows for imaging the cellular uptake of molecular imaging probes labeled with charged particle emitters such as 18F inside these chips. In this work, we investigate the quantitative imaging capabilities of Betabox for 18F beta particles, in terms of background rate, efficiency, spatial resolution, and count rate. Measurements of background and spatial resolution are considered both at room temperature (21 °C ± 1 °C) and at an elevated operating temperature (37 °C ± 1 °C), as is often required for biological assays. The background rate measured with a 4 keV energy cutoff is below 2 cph mm−2 at both 21 and 37 °C. The absolute efficiency of Betabox for the detection of 18F positron sources in contact with a PSAPD with the surface passivated from ambient light and damage is 46% ± 1%. The lower detection limit is estimated using the Rose Criterion to be 0.2 cps mm−2 for 1 min acquisitions and a 62 × 62 µm2 pixel size. The upper detection limit is approximately 21 000 cps. The spatial resolution at both 21 and 37 °C ranges from 0.4 mm FWHM at the center of the field of view (FOV), and degrades to 1 mm at a distance of 5 mm away from center yielding a useful FOV of approximately 10 × 10 mm2. We also investigate the effects on spatial resolution and sensitivity that result from the use of a polymer based microfluidic chip. For these studies we place varying layers of low-density polyethylene (LDPE) between the detector and the source and find that the spatial resolution degrades by ~180 µm for every 100 µm of LDPE film. Sensitivity is reduced by half with the inclusion of ~200 µm of additional LDPE film

  6. Nuclear and particle physics aspects of the 2{nu}{beta}{beta}-decay of {sup 150}Nd

    SciTech Connect

    Dvornicky, R.; Simkovic, F.; Faessler, A.

    2007-10-12

    A discussion is given on possible realization of the Single State Dominance (SSD) hypothesis in the case of the two-neutrino double beta decay (2{nu}{beta}{beta}-decay) of {sup l50}Nd with 1{sup -} ground state of the intermediate nucleus. We conclude that the SSD hypothesis is expected to be ruled out by precision measurement of differential characteristics of this process in running NEMO 3 or planed SuperNEMO experiments unlike some unknown low-lying 1{sup +} state of {sup 150}Pm does exist. This problem can be solved via (d,{sup 2}He) charge-exchange experiment on {sup l50}Sm. Further, we address the question about possible violation of the Pauli exclusion principle for neutrinos and its consequences for the energy distributions of the 2{nu}{beta}{beta}-decay of {sup l50}Nd. This phenomenon might be a subject of interest of NEMO 3 and SuperNEMO experiments as well.

  7. Optical imaging of the spatial distribution of beta-particles emerging from surfaces.

    PubMed Central

    Charpak, G; Dominik, W; Zaganidis, N

    1989-01-01

    The multiplication in gases of ionization electrons, by the effect of the electric fields between parallel electrodes, leads to the emission of light from the molecules excited in the avalanche process. The optical imaging of this light, with intensifiers, on charge-coupled devices permits the localization, in the gaseous volume, of the entrance points of the beta-particles emitted by radioactive compounds placed close to or at the cathode electrode. Thin slices of anatomical samples labeled with 3H show detailed structures 30 microns in size. Gels carrying 32P or 35S are imaged with accuracies of the order of 0.5 mm (full width at half maximum). In comparison with photographic emulsion, the gain in time for data taking is close to a factor of 100, with the advantage of linearity and wider dynamic range in the intensity measurement and a greatly improved signal-to-noise ratio. Images PMID:2928300

  8. Beta-delayed multi-particle emission in proton rich nuclei

    NASA Astrophysics Data System (ADS)

    Borge, M. J. G.; Axelsson, L.; Äystö, J.; Bergmann, U. C.; Boutami, R.; Deendoven, P.; Fraile, L. M.; Fynbo, H. O. U.; Honkanen, A.; Hornshøj, P.; Huikari, J.; Jokinen, A.; Jonson, B.; Markenroth, K.; Martel, I.; Mukha, I.; Nilsson, T.; Nyman, G.; Oinonen, M.; Prezado, Y.; Riisager, K.; Tengblad, O.; Rolander, K. Wilhelmsen

    2002-04-01

    In this contribution examples of the application of new technologies to disentangle the mechanism of beta-delayed multi-particle emission are given. In particular the mechanism of β-delayed two-proton emission from 31Ar is resolved and proved to be sequential, both for isospin allowed and isospin forbidden transitions. The analysis of the 9C decay has been focused in the study of the 12.2 MeV state in 9B. The decay of this state to pαα occurs sequentially, partial decay branches through the 8Be(0+,2+) and 5Li(3/2-,1/2-) intermediate states have been determined. A BGT value of 1.20(15) is deduced, compared with the BGT-value of the mirror transition, a asymmetry factor δ=3.7(12) is obtained, the largest ever observed. A preview of β3α data from 12N decay is discussed. .

  9. Laboratory Simulation of Impacts upon Aluminum Foils of the Stardust Spacecraft: Calibration of Dust Particle Size from Comet Wild 2

    NASA Technical Reports Server (NTRS)

    Kearsley, A. T.; Burchell, M. J.; Horz, F.; Cole, M. J.; Schwandt, C. S.

    2006-01-01

    Metallic aluminium alloy foils exposed on the forward, comet-facing surface of the aerogel tray on the Stardust spacecraft are likely to have been impacted by the same cometary particle population as the dedicated impact sensors and the aerogel collector. The ability of soft aluminium alloy to record hypervelocity impacts as bowl-shaped craters offers an opportunistic substrate for recognition of impacts by particles of a wide potential size range. In contrast to impact surveys conducted on samples from low Earth orbit, the simple encounter geometry for Stardust and Wild 2, with a known and constant spacecraft-particle relative velocity and effective surface-perpendicular impact trajectories, permits closely comparable simulation in laboratory experiments. For a detailed calibration programme we have selected a suite of spherical glass projectiles of uniform density and hardness characteristics, with well-documented particle size range from 10 microns to nearly 100 microns. Light gas gun buckshot firings of these particles at approximately 6km s)exp -1) onto samples of the same foil as employed on Stardust have yielded large numbers of craters. Scanning electron microscopy of both projectiles and impact features has allowed construction of a calibration plot, showing a linear relationship between impacting particle size and impact crater diameter. The close match between our experimental conditions and the Stardust mission encounter parameters should provide another opportunity to measure particle size distributions and fluxes close to the nucleus of Wild 2, independent of the active impact detector instruments aboard the Stardust spacecraft.

  10. Direct determination of 90Sr and 147Pm in Chernobyl hot particles collected in Kiev using beta absorption method.

    PubMed

    Papp, Z; Bolyós, A; Dezsó, Z; Daróczy, S

    1997-12-01

    59 hot particles were collected in Kiev, Ukraine, in 1987. All but one were prepared from a moss carpet of 360 cm2 area. Radionuclide composition of the hot particles was investigated by gamma-spectrometry and beta absorption method. Pure beta emitters 90Sr and 147Pm were determined in 25 hot particles measuring the beta absorption curves of the hot particles with an end-window Geiger-Müller counter and decomposing the curves in order to obtain the contributions of 90Sr and 147Pm to the total beta counting rate. All but one of the hot particles were found to be the debris of the fuel. The activity ratio 90Sr:l44Ce was 0.052 in good agreement with theoretical calculations on core inventories. This means that strontium behaved as a nonvolatile element in the process of the formation of the hot particles investigated. The activity ratio 147Pm:144Ce was 0.078 which is half of the theoretical result. Although 147Pm is considered to be a refractory nuclide, it seems that significant part of 147Pm went to the homogeneous fraction of the general fallout. The surface density of hot particles (of higher than about 50 Bq activity) was about 1,600 m(-2) and that of the activities of the nuclides 90Sr, 106Ru, 134Cs, 137Cs, 144Ce and 147Pm as components of hot particles was 12.2, 54.3, 5.9, 9.7, 234 and 18.3 kBq m(-2) (activity values counted for 26 April 1986), respectively, in downtown Kiev city in 1987.

  11. Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols.

    PubMed

    Dacunto, Philip J; Klepeis, Neil E; Cheng, Kai-Chung; Acevedo-Bolton, Viviana; Jiang, Ruo-Ting; Repace, James L; Ott, Wayne R; Hildemann, Lynn M

    2015-11-01

    Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment. We conducted a total of 64 experiments with a suite of instruments including a Dylos DC1100, another real-time laser photometer (TSI SidePak™ Model AM-510 Personal Aerosol Monitor), and a gravimetric sampling apparatus to estimate Dylos calibration factors for emissions from 17 different common indoor sources including cigarettes, incense, fried bacon, chicken, and hamburger. Comparison of minute-by-minute data from the Dylos with the gravimetrically calibrated SidePak yielded relationships that enable the conversion of the raw Dylos particle counts less than 2.5 μm (in #/0.01 ft(3)) to estimated PM2.5 mass concentration (e.g. μg m(-3)). The relationship between the exponentially-decaying Dylos particle counts and PM2.5 mass concentration can be described by a theoretically-derived power law with source-specific empirical parameters. A linear relationship (calibration factor) is applicable to fresh or quickly decaying emissions (i.e., before the aerosol has aged and differential decay rates introduce curvature into the relationship). The empirical parameters for the power-law relationships vary greatly both between and within source types, although linear factors appear to have lower uncertainty. The Dylos Air Quality Monitor is likely most useful for providing instantaneous feedback and context on mass particle levels in home and work situations for field-survey or personal awareness applications.

  12. Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols.

    PubMed

    Dacunto, Philip J; Klepeis, Neil E; Cheng, Kai-Chung; Acevedo-Bolton, Viviana; Jiang, Ruo-Ting; Repace, James L; Ott, Wayne R; Hildemann, Lynn M

    2015-11-01

    Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment. We conducted a total of 64 experiments with a suite of instruments including a Dylos DC1100, another real-time laser photometer (TSI SidePak™ Model AM-510 Personal Aerosol Monitor), and a gravimetric sampling apparatus to estimate Dylos calibration factors for emissions from 17 different common indoor sources including cigarettes, incense, fried bacon, chicken, and hamburger. Comparison of minute-by-minute data from the Dylos with the gravimetrically calibrated SidePak yielded relationships that enable the conversion of the raw Dylos particle counts less than 2.5 μm (in #/0.01 ft(3)) to estimated PM2.5 mass concentration (e.g. μg m(-3)). The relationship between the exponentially-decaying Dylos particle counts and PM2.5 mass concentration can be described by a theoretically-derived power law with source-specific empirical parameters. A linear relationship (calibration factor) is applicable to fresh or quickly decaying emissions (i.e., before the aerosol has aged and differential decay rates introduce curvature into the relationship). The empirical parameters for the power-law relationships vary greatly both between and within source types, although linear factors appear to have lower uncertainty. The Dylos Air Quality Monitor is likely most useful for providing instantaneous feedback and context on mass particle levels in home and work situations for field-survey or personal awareness applications. PMID:26487426

  13. Particle acceleration during magnetic reconnection in a low-beta pair plasma

    NASA Astrophysics Data System (ADS)

    Guo, Fan; Li, Hui; Daughton, William; Li, Xiaocan; Liu, Yi-Hsin

    2016-05-01

    Plasma energization through magnetic reconnection in the magnetically dominated regime featured by low plasma beta ( β = 8 π n k T 0 / B 2 ≪ 1 ) and/or high magnetization ( σ = B 2 / ( 4 π n m c 2 ) ≫ 1 ) is important in a series of astrophysical systems such as solar flares, pulsar wind nebula, and relativistic jets from black holes. In this paper, we review the recent progress on kinetic simulations of this process and further discuss plasma dynamics and particle acceleration in a low-β reconnection layer that consists of electron-positron pairs. We also examine the effect of different initial thermal temperatures on the resulting particle energy spectra. While earlier papers have concluded that the spectral index is smaller for higher σ, our simulations show that the spectral index approaches p = 1 for sufficiently low plasma β, even if σ ˜ 1 . Since this predicted spectral index in the idealized limit is harder than most observations, it is important to consider effects that can lead to a softer spectrum such as open boundary simulations. We also remark that the effects of three-dimensional reconnection physics and turbulence on reconnection need to be addressed in the future.

  14. Cellular uptake of beta-carotene from protein stabilized solid lipid nano-particles prepared by homogenization-evaporation method

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Using a homogenization-evaporation method, beta-carotene (BC) loaded nano-particles were prepared with different ratios of food-grade sodium caseinate (SC), whey protein isolate (WPI), or soy protein isolate (SPI) to BC and evaluated for their physiochemical stability, in vitro cytotoxicity, and cel...

  15. Localization and quantitation of tritiated compounds in tissue sections with a gaseous detector of beta particles: comparison with film autoradiography.

    PubMed Central

    Tribollet, E; Dreifuss, J J; Charpak, G; Dominik, W; Zaganidis, N

    1991-01-01

    Quantitative analysis of tritium polymer standards and of brain sections labeled with tritiated vasopressin was carried out by using a gaseous detector of beta particles designed for this purpose. The gaseous detector showed major advantages compared with film autoradiography: the linearity and the large dynamic range of intensity measurements as well as the short time needed for data acquisition. Images PMID:1996346

  16. Localization and quantitation of tritiated compounds in tissue sections with a gaseous detector of beta particles: Comparison with film autoradiography

    SciTech Connect

    Tribollet, E.; Dreifuss, J.J.; Charpak, G.; Dominik, W.; Zaganidis, N. )

    1991-02-15

    Quantitative analysis of tritium polymer standards and of brain sections labeled with tritiated vasopressin was carried out by using a gaseous detector of beta particles designed for this purpose. The gaseous detector showed major advantages compared with film autoradiography: the linearity and the large dynamic range of intensity measurements as well as the short time needed for data acquisition.

  17. Calibration method for the lidar-observed stratospheric depolarization ratio in the presence of liquid aerosol particles.

    PubMed

    Adachi, H; Shibata, T; Iwasaka, Y; Fujiwara, M

    2001-12-20

    A fine calibration of the depolarization ratio is required for a detailed interpretation of lidar-observed polar stratospheric clouds. We propose a procedure for analyzing data by using atmospheric depolarization lidar. The method is based on a plot of deltaT versus (1 - RT(-1)), where deltaT is the total depolarization ratio and RT is the total backscattering ratio. Assuming that there are only spherical particles in some altitude ranges of the lidar data, the characteristics of the plot of deltaT versus (1 - RT(-1)) lead to a simple but effective calibration method for deltaT. Additionally, the depolarization of air molecules deltam can be determined in the process of deltaT calibration. We compared determined values with theoretically calculated values for the depolarization of air to test the proposed method. The deltam value was calculated from the lidar data acquired at Ny-Alesund (79 degrees N, 12 degrees E), Svalbard in winter 1994-1995. When only sulfate aerosols were present on 24 December 1994, deltam was 0.46 +/- 0.35%. When the particles consisted of sulfate aerosols and spherical particles of polar stratospheric clouds on 4 January 1995, deltam was 0.45 +/- 0.07%. Both deltam values were in good agreement with the theoretically calculated value, 0.50 +/- 0.03%.

  18. Preliminary calibration plan for the Advanced Particles and Field Observatory (APAFO) magnetometer experiment

    NASA Technical Reports Server (NTRS)

    Voorhies, C. V.; Langel, R. A.; Slavin, J.; Lancaster, E. R.; Jones, S.

    1991-01-01

    Prelaunch and postlaunch calibration plans for the APAFO magnetometer experiment are presented. A study of tradeoffs between boom length and spacecraft field is described; the results are summarized. The prelaunch plan includes: calibration of the Vector Fluxgate Magnetometer (VFM), Star Sensors, and Scalar Helium Magnetometer (SHM); optical bench integration; and acquisition of basic spacecraft field data. Postlaunch calibration has two phases. In phase one, SHM data are used to calibrate the VFM, total vector magnetic field data are used to calibrate a physical model of the spacecraft field, and both calibrations are refined by iteration. In phase two, corrected vector data are transformed into geocentric coordinates, previously undetected spacecraft fields are isolated, and initial geomagnetic field models are computed. Provided the SHM is accurate to the required 1.0 nT and can be used to calibrate the VFM to the required 3.0- nT accuracy, the tradeoff study indicates that a 12 m boom and a spacecraft field model uncertainty of 5 percent together allow the 1.0 nT spacecraft field error requirement to be met.

  19. Beta experiment

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A focused laser doppler velocimeter (LDV) system was developed for the measurement of atmospheric backscatter (beta) from aerosols at infrared wavelengths. A Doppler signal generator was used in mapping the coherent sensitive focal volume of a focused LDV system. System calibration data was analyzed during the flight test activity scheduled for the Beta system. These analyses were performed to determine the acceptability of the Beta measurement system's performance.

  20. Stardust: An overview of the tracks in the aerogel (calibration, classification and particle size distribution)

    NASA Astrophysics Data System (ADS)

    Burchell, M. J.; Fairey, S. J.; Hörz, F.; Wozniakiewicz, P. J.; Kearsley, A. T.; Brownlee, D. E.; See, T. H.; Westphal, A.; Green, S. F.; Trigo-Rodríguez, J. M.

    2007-08-01

    The NASA Stardust mission (1) to comet P/Wild-2 returned to Earth in January 2006 carrying a cargo of dust captured in aerogel and residue rich craters in aluminium foils (2). Aerogel is a low density, highly porous material (3, 4). The aerogel that was carried by Stardust in the cometary dust collector trays was a SiO2 aerogel, arranged in blocks 4 cm x 2 cm (front face) and 3 cm deep, with density which varied smoothly from 5 mg/cc at the front surface to 50 mg/cc at the rear surface (5). A first look at the whole cometary dust tray at NASA showed that there were many impact features in the aerogel. During the Preliminary Examination period about 15% of the aerogel blocks were removed and studied in detail. The tracks observed in these blocks were classified into three groups: Type A were long relatively narrow tracks of "carrot shape", Type B tracks were again fairly long but had a large bulbous region at the top and appear like the bowl and stem of a flute champagne glass, Type C were purely bulbous tracks with no stem emerging beneath them. Data on the sizes and relative populations of these tracks will be given (also see (6)) along with a discussion of their implications for impactor composition. Laboratory calibrations of the impacts in aerogel have been carried out using glass beads and these permit an estimate of the size of the impactor based on the measured track properties (6). When applied to the tracks measured in the Stardust aerogel, a cumulative particle size distribution was obtained (7) which will be discussed. References (1) Brownlee D.E. et al., J. Geophys. Res. 108, E10, 8111, 2003. (2) Brownlee D.E. et al., Science 314, 1711 - 1716. 2006. (3) Kistler S.S., Nature 127, 741, 1931. (4) Burchell M.J. et al., Ann. Rev. Earth. Planet. Sci. 34, 385 - 418, 2006. (5) Tsou P. et al., J. Geophys. Res. 108(E10), 8113, 2003. (6) Burchell et al., submitted to MAPS, 2006. (7) Hörz F. et al., Science 314, 1716 - 1719, 2006.

  1. Beta Backscatter Measures the Hardness of Rubber

    NASA Technical Reports Server (NTRS)

    Morrissey, E. T.; Roje, F. N.

    1986-01-01

    Nondestructive testing method determines hardness, on Shore scale, of room-temperature-vulcanizing silicone rubber. Measures backscattered beta particles; backscattered radiation count directly proportional to Shore hardness. Test set calibrated with specimen, Shore hardness known from mechanical durometer test. Specimen of unknown hardness tested, and radiation count recorded. Count compared with known sample to find Shore hardness of unknown.

  2. Precision calibration of calorimeter electronics in the D0 liquid argon/uranium particle detector

    SciTech Connect

    Huffman, D.L.

    1991-12-01

    The ability to cross calibrate thousands of channels of detector electronics is of prime importance. This paper will describe the system used to deliver and distribute a 300 nanosecond pulse across 50,000 channels of electronics with better than 0.25% difference between channels from a location more than 200 feet away. The system is used for both cross calibration and functionality checking, (i.e., missing channels). Design of a fixed width pulse generator of high stability is presented as a key ingredient in the system`s overall performance. In addition, the design of a controlled impedance distribution system is discussed. 2 refs.

  3. Real-time particle monitor calibration factors and PM2.5 emission factors for multiple indoor sources.

    PubMed

    Dacunto, Philip J; Cheng, Kai-Chung; Acevedo-Bolton, Viviana; Jiang, Ruo-Ting; Klepeis, Neil E; Repace, James L; Ott, Wayne R; Hildemann, Lynn M

    2013-08-01

    Indoor sources can greatly contribute to personal exposure to particulate matter less than 2.5 μm in diameter (PM2.5). To accurately assess PM2.5 mass emission factors and concentrations, real-time particle monitors must be calibrated for individual sources. Sixty-six experiments were conducted with a common, real-time laser photometer (TSI SidePak™ Model AM510 Personal Aerosol Monitor) and a filter-based PM2.5 gravimetric sampler to quantify the monitor calibration factors (CFs), and to estimate emission factors for common indoor sources including cigarettes, incense, cooking, candles, and fireplaces. Calibration factors for these indoor sources were all significantly less than the factory-set CF of 1.0, ranging from 0.32 (cigarette smoke) to 0.70 (hamburger). Stick incense had a CF of 0.35, while fireplace emissions ranged from 0.44-0.47. Cooking source CFs ranged from 0.41 (fried bacon) to 0.65-0.70 (fried pork chops, salmon, and hamburger). The CFs of combined sources (e.g., cooking and cigarette emissions mixed) were linear combinations of the CFs of the component sources. The highest PM2.5 emission factors per time period were from burned foods and fireplaces (15-16 mg min(-1)), and the lowest from cooking foods such as pizza and ground beef (0.1-0.2 mg min(-1)). PMID:23784066

  4. Integrated development facility for the calibration of low-energy charged particle flight instrumentation

    NASA Technical Reports Server (NTRS)

    Biddle, A. P.; Reynolds, J. M.

    1986-01-01

    The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

  5. Design and calibration of a digital Fourier holographic microscope for particle sizing via goniometry and optical scatter imaging in transmission.

    PubMed

    Rossi, Vincent M; Jacques, Steven L

    2016-06-13

    Goniometry and optical scatter imaging have been used for optical determination of particle size based upon optical scattering. Polystyrene microspheres in suspension serve as a standard for system validation purposes. The design and calibration of a digital Fourier holographic microscope (DFHM) are reported. Of crucial importance is the appropriate scaling of scattering angle space in the conjugate Fourier plane. A detailed description of this calibration process is described. Spatial filtering of the acquired digital hologram to use photons scattered within a restricted angular range produces an image. A pair of images, one using photons narrowly scattered within 8 - 15° (LNA), and one using photons broadly scattered within 8 - 39° (HNA), are produced. An image based on the ratio of these two images, OSIR = HNA/LNA, following Boustany et al. (2002), yields a 2D Optical Scatter Image (OSI) whose contrast is based on the angular dependence of photon scattering and is sensitive to the microsphere size, especially in the 0.5-1.0µm range. Goniometric results are also given for polystyrene microspheres in suspension as additional proof of principle for particle sizing via the DFHM. PMID:27410298

  6. Self-calibrating highly sensitive dynamic capacitance sensor: towards rapid sensing and counting of particles in laminar flow systems.

    PubMed

    Guha, S; Schmalz, K; Wenger, Ch; Herzel, F

    2015-05-01

    In this report we propose a sensor architecture and a corresponding read-out technique on silicon for the detection of dynamic capacitance change. This approach can be applied to rapid particle counting and single particle sensing in a fluidic system. The sensing principle is based on capacitance variation of an interdigitated electrode (IDE) structure embedded in an oscillator circuit. The capacitance scaling of the IDE results in frequency modulation of the oscillator. A demodulator architecture is employed to provide a read-out of the frequency modulation caused by the capacitance change. A self-calibrating technique is employed at the read-out amplifier stage. The capacitance variation of the IDE due to particle flow causing frequency modulation and the corresponding demodulator read-out has been analytically modelled. Experimental verification of the established model and the functionality of the sensor chip were shown using a modulating capacitor independent of fluidic integration. The initial results show that the sensor is capable of detecting frequency changes of the order of 100 parts per million (PPM), which translates to a shift of 1.43 MHz at 14.3 GHz operating frequency. It is also shown that a capacitance change every 3 μs can be accurately detected.

  7. Design and calibration of a CO{sub 2}-laser nephelometer to measure the radiative properties of coal particles

    SciTech Connect

    Bush, M.B.; D`sa, D.A.; Manickavasagam, S.; Menguec, M.P.

    1990-12-31

    In is paper, we will discuss the design and calibration of a CO{sub 2}-laser nephelometer for angular light scattering measurements to determine the effective radiative properties of pulverized-coal particles in a non-flame, planar system in-situ. A nephelometer is an instrument used for angular detection of scattered light incident on a cloud of particles. Its essential elements include a collimated light source and an arm which houses light collection optics and detectors. The arm can be rotated to record the angular scattered intensity distribution. A major problem when conducting experiments of this nature is that the intensity of the scattered light by pulverized-coal particles at angles other than the forward scattering direction can be as much as two to three orders of magnitude lower than the intensity at angles close to {theta} = O{sup o}. This effect is more pronounced for larger size parameters. In order to have sufficiently strong signals at a wide range of angles, a 50 watt CO{sub 2}-laser operating at 10.6 {mu}m is used in the experiments.

  8. Effect of reinforcement particle size on in vitro behavior of beta-tricalcium phosphate-reinforced high-density polyethylene: a novel orthopedic composite.

    PubMed

    Homaeigohar, S S H; Shokrgozar, M A; Javadpour, J; Khavandi, A; Sadi, A Yari

    2006-07-01

    Beta-tricalcium phosphate-reinforced high-density polyethylene (beta-TCP/HDPE) is a new biomaterial, which was made to simulate bone composition and study its capacity to act like bony tissues. This material was produced by replacing mineral component and collagen soft tissue of bone with beta-TCP and HDPE, respectively. The biocompatibility of composite samples with different volume fractions of TCP (20, 30, and 40 vol %) and two different particle sizes (80-100 and 120-140 mesh size) was examined in vitro using the osteoblast cell line G-292 by proliferation, alkaline phosphatase (ALP) production, and cell adhesion assays. Cell-material interaction on the surface of the composites was observed by scanning electron microscopy (SEM). The effect of beta-TCP particle size on behavior of the osteoblast cell line was compared between two groups of the composite samples containing smaller and larger reinforcement particle sizes as well as with those of a negative control. In general, results showed that the composite samples containing larger particles supported a higher rate of proliferation and ALP production by osteoblast cells after 3, 7, and 14 days of incubation compared to the composite samples with smaller particle size and control. Furthermore, more cells were attached to the surface of composite samples containing larger particle size when compared to the smaller particle size composites (p<0.05). This number was nearly equal with numbers adhered on negative control [tissue culture polystyrene (TPS)] and significantly higher in comparison with composite control [polyethylene (PE)] (p<0.05). Adhered cells presented a normal morphology by SEM and many of the cells were seen to be undergoing cell division. These findings indicate that beta-TCP/HDPE composites are biocompatible, nontoxic, and in some cases, act to stimulate proliferation of the cells, ALP production, and cell adhesion when compared to the control counterparts. Furthermore, beta-TCP/HDPE samples

  9. Accounting for beta-particle energy loss to cortical bone via paired-image radiation transport (PIRT).

    PubMed

    Shah, Amish P; Rajon, Didier A; Patton, Phillip W; Jokisch, Derek W; Bolch, Wesley E

    2005-05-01

    Current methods of skeletal dose assessment in both medical physics (radionuclide therapy) and health physics (dose reconstruction and risk assessment) rely heavily on a single set of bone and marrow cavity chord-length distributions in which particle energy deposition is tracked within an infinite extent of trabecular spongiosa, with no allowance for particle escape to cortical bone. In the present study, we introduce a paired-image radiation transport (PIRT) model which provides a more realistic three-dimensional (3D) geometry for particle transport in the skeletal site at both microscopic and macroscopic levels of its histology. Ex vivo CT scans were acquired of the pelvis, cranial cap, and individual ribs excised from a 66-year male cadaver (BMI of 22.7 kg m(-2)). For the three skeletal sites, regions of trabecular spongiosa and cortical bone were identified and segmented. Physical sections of interior spongiosa were taken and subjected to microCT imaging. Voxels within the resulting microCT images were then segmented and labeled as regions of bone trabeculae, endosteum, active marrow, and inactive marrow through application of image processing algorithms. The PIRT methodology was then implemented within the EGSNRC radiation transport code whereby electrons of various initial energies are simultaneously tracked within both the ex vivo CT macroimage and the CT microimage of the skeletal site. At initial electron energies greater than 50-200 keV, a divergence in absorbed fractions to active marrow are noted between PIRT model simulations and those estimated under existing techniques of infinite spongiosa transport. Calculations of radionuclide S values under both methodologies imply that current chord-based models may overestimate the absorbed dose to active bone marrow in these skeletal sites by 0% to 27% for low-energy beta emitters (33P, 169Er, and 177Lu), by approximately 4% to 49% for intermediate-energy beta emitters (153Sm, 186Re, and 89Sr), and by

  10. Atomic effects of beta decay in astrophysics and in elementary particle physics

    NASA Astrophysics Data System (ADS)

    Chen, Zonghua

    The bound-state beta decay of Re-187 and its application in Astrophysics is studied. There existed an uncertainty in the ratio of rhop of bound-state to continuum beta decay of Re-187 in both theory and experiment. A more definite theoretical result of rhop of approximately 1 percent is obtained by using single-configuration and multi-configuration Hartree-Fock-Dirac approximations. The results obtained are close to those obtained by Williams, Fowler, and Koonin by a modified Thomas-Fermi model. The bound-state beta decay of Re-187 at high temperatures is also studied. A generalization of the Thomas-Fermi results of various energy contributions to the ground-state energy of a neutral atom is also presented. An analytical expression for the ratio of the electron-electron to electron-nuclear interaction is obtained by the corrected Thomas-Fermi result, the ratio obtained gives a better agreement with the Hartree-Fock numerical results.

  11. A computerized low-level alpha and beta particle detection system

    SciTech Connect

    Hjellming, T. ); McKlveen, J.W.; Klingler, G.W. )

    1989-12-01

    This paper reports that at Arizona State University's Radiation Measurements Facility, a microprocessor simultaneously controls a commercial gas-flow proportional counter and a prototype low background anticoincidence beta scintillation counter. This fully automatic system supports multiple count scheduling, routine quality assurance and operational checks, on-line diagnostic routines, and detector high voltage control. An operator may execute MS-DOS programs using the microcomputer, while count data is being acquired asynchronously on special hardware interface cards. Data analysis and output is available in both graphic and tabular formats.

  12. Calibration and efficiency curve of SANAEM ionization chamber for activity measurements.

    PubMed

    Yeltepe, Emin; Kossert, Karsten; Dirican, Abdullah; Nähle, Ole; Niedergesäß, Christiane; Kemal Şahin, Namik

    2016-03-01

    A commercially available Fidelis ionization chamber was calibrated and assessed in PTB with activity standard solutions. The long-term stability and linearity of the system was checked. Energy-dependent efficiency curves for photons and beta particles were determined, using an iterative method in Excel™, to enable calibration factors to be calculated for radionuclides which were not used in the calibration. Relative deviations between experimental and calculated radionuclide efficiencies are of the order of 1% for most photon emitters and below 5% for pure beta emitters. The system will enable TAEK-SANAEM to provide traceable activity measurements.

  13. Beta Androstenediol Mitigates the Damage of 1 GeV/n Fe Ion Particle Radiation to the Hematopoietic System

    SciTech Connect

    Loria R.; Guida P.; Loria, R.; Beckman, M.; Contaifer, D.; Tamariz, F.; Gibb, D.; Thompson, L.; Guida, P.

    2010-09-07

    Space exploration is associated with exposure to 1-3 Gy solar particle radiation and galactic cosmic radiation that could increase cancer rates. Effective nontoxic countermeasures to high linear energy transfer (LET) radiation exposure are highly desirable but currently not available. The aim was to determine whether a single subcutaneous injection of androstenediol ({Delta}(5) androsten-3{beta}, 17{beta}-diol [AED]) could mitigate and restore the mouse hematopoetic system from the radiation-mediated injury of 3 Gy whole-body high LET (56)Fe(26+) exposure. The findings show that postradiation AED treatment has an overall positive and significant beneficial effect to restore the levels of hematopoeitic elements (p < 0.001). Androstenediol treatment significantly increased monocyte levels at days 4, 7, and 14 and, similarly, increased red blood cell, hemoglobin, and platelet counts. Flow cytometry analysis 14 days after radiation and AED treatment demonstrated an increase (p < 0.05) in bone marrow cells counts. Ex vivo osteoclastogenesis studies show that AED treatment is necessary and advantageous for the development and restoration of osteoclastogenesis after radiation exposure. These findings clearly show that androstenediol functions as a countermeasure to remedy hematopoeitic injury mediated by high LET iron ion radiation. Presently, no other agent has been shown to have such properties.

  14. Measurement of Beta Particles Induced Electron-Hole Pairs Recombination in Depletion Region of GaAs PN Junction

    NASA Astrophysics Data System (ADS)

    Chen, Hai-Yang; Jiang, Lan; Li, Da-Rang

    2011-05-01

    PN junctions and schottky diodes are widely employed as electron-hole pair collectors in electron beam induced current (EBIC) techniques and betavoltaic batteries, in which the recombination in depletion regions is ignored. We measured the beta particles induced electron-hole pairs recombination in the depletion region of a GaAs P+PN+ junction, based on comparisons between measured short currents and ideal values. The results show that only 20% electron-hole pairs in the depletion can be collected, causing the short current. This indicates an electron-hole pair diffusion length of 0.2μm in the depletion region. Hence, it is necessary to evaluate the recombination in the EBIC techniques and betavoltaic design.

  15. A primary standard for the measurement of alpha and beta particle surface emission rate from large area reference sources.

    PubMed

    Ravindra, Anuradha; Kulkarni, D B; Joseph, Leena; Kulkarni, M S; Babu, D A R

    2016-01-01

    A large area windowless gas flow multi wire proportional counting system for the calibration of large area reference sources has been developed as a primary standard at Bhabha Atomic Research Centre (BARC). The counting system consists of a multi wire proportional counter (MWPC), vacuum system, gas flow system and pulse processing units. The MWPC detector assembly consists of a vacuum tight aluminum enclosure, multi wire grid and sliding source tray. Various detector characteristics like operating characteristics curve, Fe-55 spectrum for beta discriminator threshold setting and dead time of the measurement system were studied and determined in order to achieve an optimized detection capability. The surface emission rates of different source strengths were measured and their relative combined standard uncertainties were determined. Large Area Sources Comparison Exercise (LASCE) was organized by International Committee on Radionuclide Metrology (ICRM) working group and coordinated by National Institute for Ionising Radiation Metrology (ENEA), Italy, to demonstrate equivalence of surface emission rate measurements at the international platform. BARC participated in the programme and the results of LASCE are also discussed in this paper.

  16. A primary standard for the measurement of alpha and beta particle surface emission rate from large area reference sources.

    PubMed

    Ravindra, Anuradha; Kulkarni, D B; Joseph, Leena; Kulkarni, M S; Babu, D A R

    2016-01-01

    A large area windowless gas flow multi wire proportional counting system for the calibration of large area reference sources has been developed as a primary standard at Bhabha Atomic Research Centre (BARC). The counting system consists of a multi wire proportional counter (MWPC), vacuum system, gas flow system and pulse processing units. The MWPC detector assembly consists of a vacuum tight aluminum enclosure, multi wire grid and sliding source tray. Various detector characteristics like operating characteristics curve, Fe-55 spectrum for beta discriminator threshold setting and dead time of the measurement system were studied and determined in order to achieve an optimized detection capability. The surface emission rates of different source strengths were measured and their relative combined standard uncertainties were determined. Large Area Sources Comparison Exercise (LASCE) was organized by International Committee on Radionuclide Metrology (ICRM) working group and coordinated by National Institute for Ionising Radiation Metrology (ENEA), Italy, to demonstrate equivalence of surface emission rate measurements at the international platform. BARC participated in the programme and the results of LASCE are also discussed in this paper. PMID:26457924

  17. Direct determination of {sup 90}Sr and {sup 147}Pm in Chernobyl hot particles collected in Kiev using beta absorption method

    SciTech Connect

    Papp, Z.; Bolyos, A.; Dezso, Z.; Daroczy, S.

    1997-12-01

    59 hot particles were collected in Kiev, Ukraine, in 1987. All but one were prepared from a moss carpet of 360 cm{sup 2} area. Radionuclide composition of the hot particles was investigated by gamma-spectrometry and beta absorption method. Pure beta emitters {sup 90}Sr and {sup 147}Pm were determined in 25 hot particles measuring the beta absorption curves of the hot particles with an end-window Geiger-Mueller counter and decomposing the curves in order to obtain the contributions of {sup 90}Sr and {sup 147}Pm to the total beta counting rate. All but one of the hot particles were found to be the debris of the fuel. The activity ratio {sup 90}Sr:{sup 144}Ce was 0.078 which is half of the theoretical result. Although {sup 147}Pm is considered to be a refractory nuclide, it seems that significant part of {sup 147}Pm went to the homogeneous fraction of the general fallout. The surface density of hot particles (of higher than about 50 Bq activity) was about 1,600 m{sup -2} and that of the activities of the nuclides {sup 90}Sr, {sup 106}Ru, {sup 134}Cs, {sup 137}Cs, {sup 144}Ce and {sup 147}Pm as components of hot particles was 12.2, 54.3, 5.9, 9.7, 234 and 18.3 kBq m{sup -2} (activity values counted for 26 April 1986), respectively, in downtown Kiev city in 1987.

  18. Requirements regarding dose rate and exposure time for killing of tumour cells in beta particle radionuclide therapy

    PubMed Central

    Eriksson, Veronika; Stenerlöw, Bo; Lundqvist, Hans

    2006-01-01

    Purpose The purpose of this study was to identify combinations of dose rate and exposure time that have the potential to provide curative treatment with targeted radionuclide therapy applying low dose rate beta irradiation. Methods Five tumour cell lines, U-373MG and U-118MG gliomas, HT-29 colon carcinoma, A-431 cervical squamous carcinoma and SKBR-3 breast cancer, were used. An experimental model with 105 tumour cells in each sample was irradiated with low dose rate beta particles. The criterion for successful treatment was absence of recovery of cells during a follow-up period of 3 months. The initial dose rates were in the range 0.1–0.8 Gy/h, and the cells were continuously exposed for 1, 3 or 7 days. These combinations covered dose rates and doses achievable in targeted radionuclide therapy. Results Continuous irradiation with dose rates of 0.2–0.3 and 0.4–0.6 Gy/h for 7 and 3 days, respectively, could kill all cells in each tumour cell sample. These treatments gave total radiation doses of 30–40 Gy. However, when exposed for just 24 h with about 0.8 Gy/h, only the SKBR-3 cells were successfully treated; all the other cell types recovered. There were large cell type-dependent variations in the growth delay patterns for the cultures that recovered. The U-118MG cells were most resistant and the U-373MG and SKBR-3 cells most sensitive to the treatments. The HT-29 and A-431 cells were intermediate. Conclusion The results serve as a guideline for the combinations of dose rate and exposure time necessary to kill tumour cells when applying low dose rate beta irradiation. The shift from recovery to “cure” fell within a narrow range of dose rate and exposure time combinations. PMID:16718515

  19. Near-bottom suspended matter concentration on the Continental Shelf during storms: estimates based on in situ observations of light transmission and a particle size dependent transmissometer calibration

    USGS Publications Warehouse

    Moody, J.A.; Butman, B.; Bothner, Michael H.

    1987-01-01

    A laboratory calibration of Sea Tech and Montedoro-Whitney beam transmissometers shows a linear relation between light attenuation coefficient (cp) and suspended matter concentration (SMC) for natural sediments and for glass beads. However the proportionality constant between cp and SMC depends on the particle diameter and particle type. Thus, to measure SMC, observations of light attenuation must be used with a time-variable calibration when suspended particle characteristics change with time. Because of this variable calibration, time series of light attenuation alone may not directly reflect SMC and must be interpreted with care. The near-bottom concentration of suspended matter during winter storms on the U.S. East Coast Continental Shelf is estimated from light transmission measurements made 2 m above the bottom and from the size distribution of suspended material collected simultaneously in sediment traps 3 m above the bottom. The average concentrations during six storms between December 1979 and February 1980 in the Middle Atlantic Bight ranged from 2 to 4 mg l1 (maximum concentration of 7 mg l1) and 8 to 12 mg l1 (maximum concentration of 22 mg l1) on the south flank of Georges Bank. ?? 1987.

  20. Dependence on scavenger concentration of the efficiency of quenching geminate-ion recombination fluorescence of saturated hydrocarbon liquids. [Beta particles

    SciTech Connect

    Choi, J.T.; Haglund, J.A.; Lipsky, S.

    1983-04-28

    The fluorescence of liquid bicyclohexyl, decalin (cis and trans isomers), and cyclohexane excited by /sup 85/Kr ..beta.. particles has been studied as a function of the concentration of perfluorodecalin over a concentration range, c/sub q/, from approx. =10/sup -4/ to 0.03 M. By comparison with the effect of perfluorodecalin to quench the fluorescence of these liquids when excited with 165-nm light, it is possible to extract the probability, p/sup t/, that perfluorodecalin scavenges a geminate electron. This probability is found to be well represented by the function (..cap alpha..c/sub q/)/sup 0.7//(1 + (..cap alpha..C/sub q/)/sup 0.7/) over the entire concentration range studied with ..cap alpha.. = 66 (bicyclohexyl), 70 (decalin, mixed isomers), 124 (cis-decalin), 58 (trans-decalin), and 102 (cyclohexane) M/sup -1/. The functional form of P/sup t/ is found to be in good agreement with theoretical expectations.

  1. Use of particle tracking to improve numerical model calibration and to analyze ground-water flow and contaminant migration, Massachusetts Military Reservation, western Cape Cod, Massachusetts

    USGS Publications Warehouse

    Masterson, J.P.; Walter, D.A.; Savoie, Jennifer G.

    1996-01-01

    A steady-state, three-dimensional flow model coupled with a particle-tracking algorithm was developed to assess the complex interaction of hydrogeologic conditions affecting ground-water flow and contaminant transport --including aquifer heterogeneities, hydrologic boundaries such as ponds and streams, ground-water withdrawals, and aquifer recharge to characterize the migration of contaminants emanating from beneath the Massachusetts Military Reservation, Cape Cod, Massachusetts. The known extent of contaminant plumes were used to assess the effects of changes in model input parameters on model-calculated water-table and pond altitudes, streamflow, and water-particle pathlines. Although changes in selected simulated hyodrogeologic conditions resulted in minor changes in model-calculated water-table altitudes, pond altitudes, and streamflow, these changes had significant effects on the projection of model-calculated water-particle pathlines. Therefore model calibration based simply on water levels and streamflows may be inadequate for the prediction of contaminant migration. However, model calibration that includes the sensitivity of water-particle pathlines to changes in hydrogeologic conditions can provide a valuable tool for optimizing data collection, characterizing hyodrogeology, and remediating ground-water contamination.

  2. Utilization of wavelength-shifting fibers coupled to ZnS(Ag) and plastic scintillator for simultaneous detection of alpha/beta particles

    NASA Astrophysics Data System (ADS)

    Ifergan, Y.; Dadon, S.; Israelashvili, I.; Osovizky, A.; Gonen, E.; Yehuda-Zada, Y.; Smadja, D.; Knafo, Y.; Ginzburg, D.; Kadmon, Y.; Cohen, Y.; Mazor, T.

    2015-06-01

    Low level radioactive surface contamination measurements require lightweight, large area and high efficiency detector. In most existing scintillation detectors there is a tradeoff between effective area and scintillation light collection. By using wavelength shifting (WLS) fibers the scintillation light may be collected efficiently also in a large area detector. In this study, WLS fibers were coupled to a beta sensitive plastic scintillator layer and to a alpha sensitive silver-activated zinc sulfide ZnS(Ag) layer for detecting both alpha and beta particles. The WLS fibers collect the scintillation light from the whole detector and transfer it to a single PMT. This first prototype unique configuration enables monitoring radioactive contaminated surfaces by both sides of the detector and provides high gamma rejection. In this paper, the detector structure, as well as the detector's measured linear response, will be described. The measured detection efficiency of 238Pu alpha particles (5.5 MeV) is ~63%. The measured detection efficiency for beta particles is ~89% for 90Sr-90Y (average energy of 195.8 keV, 934.8 keV), ~50% for 36Cl (average energy of 251.3 keV), and 35% for 137Cs (average energy of 156.8 keV).

  3. Transport of carbon ion test particles and hydrogen recycling in the plasma of the Columbia tokamak HBT'' (High Beta Tokamak)

    SciTech Connect

    Wang, Jian-Hua.

    1990-01-01

    Carbon impurity ion transport is studied in the Columbia High Beta Tokamak (HBT), using a carbon tipped probe which is inserted into the plasma (n{sub e} {approx} 1 {minus} 5 {times} 10{sup 14} (cm{sup {minus}3}), T{sub e} {approx} 4 {minus} 10 (eV), B{sub t} {approx} 0.2 {minus} 0.4(T)). Carbon impurity light, mainly the strong lines of C{sub II}(4267A, emitted by the C{sup +} ions) and C{sub III} (4647A, emitted by the C{sup ++} ions), is formed by the ablation or sputtering of plasma ions and by the discharge of the carbon probe itself. The diffusion transport of the carbon ions is modeled by measuring the space-and-time dependent spectral light emission of the carbon ions with a collimated optical beam and photomultiplier. The point of emission can be observed in such a way as to sample regions along and transverse to the toroidal magnetic field. The carbon ion diffusion coefficients are obtained by fitting the data to a diffusion transport model. It is found that the diffusion of the carbon ions is classical'' and is controlled by the high collisionality of the HBT plasma; the diffusion is a two-dimensional problem and the expected dependence on the charge of the impurity ion is observed. The measurement of the spatial distribution of the H{sub {alpha}} emissivity was obtained by inverting the light signals from a 4-channel polychromator, the data were used to calculate the minor-radial influx, the density, and the recycling time of neutral hydrogen atoms or molecules. The calculation shows that the particle recycling time {tau}{sub p} is comparable with the plasma energy confinement time {tau}{sub E}; therefore, the recycling of the hot plasma ions with the cold neutrals from the walls is one of the main mechanisms for loss of plasma energy.

  4. Calibrations of phase abundance, composition, and particle size distribution for olivine-orthopyroxene mixtures from reflectance spectra

    NASA Technical Reports Server (NTRS)

    Cloutis, Edward A.; Gaffey, Michael J.; Jackowski, Timothy L.; Reed, Kevin L.

    1986-01-01

    An analytical method for quantifying the characteristics (phase abundances, phase composition, and grain size) of an olivine-orthopyroxene mixture from reflectance spectra is described. The spectral parameters related to reflectance, wavelength position, and albedo are investigated; the absorption bands for the olivine-orthopyroxene mixture is also studied. Primary calibrations useful for the determination of the olivine-orthopyroxene mixture characteristics are examined.

  5. Particle Fabrication Using Inkjet Printing onto Hydrophobic Surfaces for Optimization and Calibration of Trace Contraband Detection Sensors.

    PubMed

    Gillen, Greg; Najarro, Marcela; Wight, Scott; Walker, Marlon; Verkouteren, Jennifer; Windsor, Eric; Barr, Tim; Staymates, Matthew; Urbas, Aaron

    2015-01-01

    A method has been developed to fabricate patterned arrays of micrometer-sized monodisperse solid particles of ammonium nitrate on hydrophobic silicon surfaces using inkjet printing. The method relies on dispensing one or more microdrops of a concentrated aqueous ammonium nitrate solution from a drop-on-demand (DOD) inkjet printer at specific locations on a silicon substrate rendered hydrophobic by a perfluorodecytrichlorosilane monolayer coating. The deposited liquid droplets form into the shape of a spherical shaped cap; during the evaporation process, a deposited liquid droplet maintains this geometry until it forms a solid micrometer sized particle. Arrays of solid particles are obtained by sequential translation of the printer stage. The use of DOD inkjet printing for fabrication of discrete particle arrays allows for precise control of particle characteristics (mass, diameter and height), as well as the particle number and spatial distribution on the substrate. The final mass of an individual particle is precisely determined by using gravimetric measurement of the average mass of solution ejected per microdrop. The primary application of this method is fabrication of test materials for the evaluation of spatially-resolved optical and mass spectrometry based sensors used for detecting particle residues of contraband materials, such as explosives or narcotics. PMID:26610515

  6. Particle Fabrication Using Inkjet Printing onto Hydrophobic Surfaces for Optimization and Calibration of Trace Contraband Detection Sensors

    PubMed Central

    Gillen, Greg; Najarro, Marcela; Wight, Scott; Walker, Marlon; Verkouteren, Jennifer; Windsor, Eric; Barr, Tim; Staymates, Matthew; Urbas, Aaron

    2015-01-01

    A method has been developed to fabricate patterned arrays of micrometer-sized monodisperse solid particles of ammonium nitrate on hydrophobic silicon surfaces using inkjet printing. The method relies on dispensing one or more microdrops of a concentrated aqueous ammonium nitrate solution from a drop-on-demand (DOD) inkjet printer at specific locations on a silicon substrate rendered hydrophobic by a perfluorodecytrichlorosilane monolayer coating. The deposited liquid droplets form into the shape of a spherical shaped cap; during the evaporation process, a deposited liquid droplet maintains this geometry until it forms a solid micrometer sized particle. Arrays of solid particles are obtained by sequential translation of the printer stage. The use of DOD inkjet printing for fabrication of discrete particle arrays allows for precise control of particle characteristics (mass, diameter and height), as well as the particle number and spatial distribution on the substrate. The final mass of an individual particle is precisely determined by using gravimetric measurement of the average mass of solution ejected per microdrop. The primary application of this method is fabrication of test materials for the evaluation of spatially-resolved optical and mass spectrometry based sensors used for detecting particle residues of contraband materials, such as explosives or narcotics. PMID:26610515

  7. Design and calibration of a rocket-borne electron spectrometer for investigation of particle ionization in the nighttime midlatitude E region

    NASA Technical Reports Server (NTRS)

    Voss, H. D.; Smith, L. G.

    1974-01-01

    An explanation was developed for the formation, near midnight at midlatitudes, of a broad electron density layer extending approximately from 120 to 180 km and usually referred to as the intermediate E layer. The responsible mechanism is believed to be the converging vertical ion drifts resulting from winds of the solar semidiurnal tide. Numerical solutions of the continuity equation appropriate to the intermediate layer is described for particular models of ion drift, diffusion coefficents, and ionization production. Analysis of rocket observations of the layer show that the ionization rate is highly correlated with the planetary geomagnetic index, K sub p. Particle flux measurements support the idea that energetic electrons are the principal source of this ionization. A semiconductor spectrometer experiment for investigation of the particle flux, spectrum, and angular properties was designed and successfully flown on a Nike Apache rocket. A detailed description of the theory, design, and calibration of the experiment and some preliminary results presented.

  8. Monitoring of event-based mobilization of hydrophobic pollutants in rivers: calibration of turbidity as a proxy for particle facilitated transport in field and laboratory.

    PubMed

    Rügner, Hermann; Schwientek, Marc; Egner, Marius; Grathwohl, Peter

    2014-08-15

    Transport of many pollutants in rivers is coupled to mobilization of suspended particles which typically occurs during floods. Since the amount of total suspended solids (TSS) in rivers can be monitored by turbidity measurements this may be used as a proxy for the total concentration of particle associated pollutants such as PAHs, PCBs, etc. and several heavy metals. Online turbidity measurements (e.g. by optical backscattering sensors) would then also allow for an assessment of particle and pollutant flux dynamics if once calibrated against TSS and total pollutant concentrations for a given catchment. In this study, distinct flood and thus turbidity events were sampled at high temporal resolution in three contrasting sub-catchments of the River Neckar in Southwest Germany (Ammer, Goldersbach, Steinlach) as well as in the River Neckar itself and investigated for the total amount of PAHs and TSS in water; turbidity (NTU) and grain size distributions of suspended solids were determined as well. Laboratory experiments were performed with natural river bed sediments from different locations (Ammer) to investigate PAH concentrations, TSS and turbidity during sedimentation of suspended particles under controlled conditions (yielding smaller and smaller suspended particles and TSS with time). Laboratory and field results agreed very well and showed that turbidity and TSS were linearly correlated over an extended turbidity range up to 2000 NTU for the field samples and up to 8000 NTU in lab experiments. This also holds for total PAH concentrations which can be reasonably well predicted based on turbidity measurements and TSS vs. PAHs relationships - even for high turbidity values observed during flood events (>2000 NTU). Total PAH concentrations on suspended solids were independent of grain size of suspended particles. This implies that for the rivers investigated the sorption capacity of particles did not change significantly during the observed events.

  9. ALTEA calibration

    NASA Astrophysics Data System (ADS)

    Zaconte, V.; Altea Team

    The ALTEA project is aimed at studying the possible functional damages to the Central Nervous System (CNS) due to particle radiation in space environment. The project is an international and multi-disciplinary collaboration. The ALTEA facility is an helmet-shaped device that will study concurrently the passage of cosmic radiation through the brain, the functional status of the visual system and the electrophysiological dynamics of the cortical activity. The basic instrumentation is composed by six active particle telescopes, one ElectroEncephaloGraph (EEG), a visual stimulator and a pushbutton. The telescopes are able to detect the passage of each particle measuring its energy, trajectory and released energy into the brain and identifying nuclear species. The EEG and the Visual Stimulator are able to measure the functional status of the visual system, the cortical electrophysiological activity, and to look for a correlation between incident particles, brain activity and Light Flash perceptions. These basic instruments can be used separately or in any combination, permitting several different experiments. ALTEA is scheduled to fly in the International Space Station (ISS) in November, 15th 2004. In this paper the calibration of the Flight Model of the silicon telescopes (Silicon Detector Units - SDUs) will be shown. These measures have been taken at the GSI heavy ion accelerator in Darmstadt. First calibration has been taken out in November 2003 on the SDU-FM1 using C nuclei at different energies: 100, 150, 400 and 600 Mev/n. We performed a complete beam scan of the SDU-FM1 to check functionality and homogeneity of all strips of silicon detector planes, for each beam energy we collected data to achieve good statistics and finally we put two different thickness of Aluminium and Plexiglas in front of the detector in order to study fragmentations. This test has been carried out with a Test Equipment to simulate the Digital Acquisition Unit (DAU). We are scheduled to

  10. Characterization and calibration of a capacitive diaphragm gauge manometer for the measurement of dust particles in vacuum

    NASA Astrophysics Data System (ADS)

    Cho, S.-G.; Hong, S.-H.; Woo, H.-J.; Park, S.-J.; Park, E.-K.; Oh, Y.-S.; Kim, J.-W.; Chung, K.-S.

    2013-07-01

    A capacitive diaphragm gauge (CDG) has been modified to measure the amount of accumulated in-vessel dust in tokamaks. In order to pin point the mass load on the CDG, aluminum dish is used. Calibrations show that the CDG has a measurement range from 2.2 g to 6.7 g with a minimum detection mass of 30 mg. Long term stability of measured signal is obtained at least more than 12 h operation with the atmospheric pressure and under vacuum. The CDG will be installed in KSTAR (Korea Superconducting Tokamak Advanced Research) device in 2012 campaign to measure the amount of in-vessel dusts.

  11. Yeast whole glucan particle (WGP) beta-glucan in conjunction with antitumour monoclonal antibodies to treat cancer.

    PubMed

    Yan, Jun; Allendorf, Daniel J; Brandley, Brian

    2005-05-01

    Beta-glucans, biological response modifiers (BRMs) derived from the cell walls of yeast and other sources, have been demonstrated to prime leukocyte complement receptor 3 (CR3), thus enabling these cells to kill tumours opsonised with complement fragment iC3b. Many tumours activate complement via the classical pathway mediated by antitumour monoclonal antibodies (mAbs) or natural antibodies. Studies into the cellular and molecular mechanisms of action have demonstrated that orally administrated yeast beta-glucans are ingested and processed by macrophages. These macrophages secrete the active moiety that primes neutrophil CR3 to kill iC3b-opsonised tumour cells. Extensive studies in preclinical animal tumour models have demonstrated the efficacy of combined oral particulate yeast beta-glucan with antitumour mAb therapy in terms of tumour regression and long-term survival. It is proposed that the addition of beta-glucan will further improve the clinical therapeutic efficacy of antitumour mAbs in cancer patients.

  12. Measurement of $\\beta_s$ at CDF

    SciTech Connect

    Oakes, Louise; /Oxford U.

    2011-02-01

    The latest results for the measurement of the CP violating phase {beta}{sub s} in B{sub s}{sup 0} {yields} J/{Psi}{phi} decays, from 5.2 fb{sup -1} integrated luminosity of CDF data are presented. For the first time, this measurement includes the contribution of B{sub s}{sup 0} {yields} J/{Psi}K{sup +}K{sup -} or B{sub s}{sup 0} {yields} J/{Psi}f{sub 0} events to the signal sample, where the f{sub 0} and non-resonant K{sup +}K{sup -} are S-wave states. Additional improvements to the analysis include more than doubling the signal sample, improved selection and particle ID, and fully calibrated flavour tagging for the full dataset. Additionally, the world's most precise single measurements of the B{sub s}{sup 0} lifetime, {tau}{sub s}, and width difference, {Delta}{Gamma}{sub s} are given.

  13. Monitoring of event based mobilization of hydrophobic pollutants in rivers: Calibration of turbidity as a proxy for particle facilitated transport

    NASA Astrophysics Data System (ADS)

    Rügner, Hermann; Schwientek, Marc; Grathwohl, Peter

    2014-05-01

    Transport of many pollutants in rivers is coupled to transport of suspended particles which is typically enhanced during events such as floods, snow melts etc. As the amount of total suspended solids (TSS) in rivers can be monitored by turbidity measurements this may be used as a proxy for the total concentration of particle associated pollutants in rivers such as polycyclic aromatic hydrocarbons (PAHs), PCBs, etc. and several heavy metals. On-line turbidity measurements (e.g. by optical backscattering sensors) then allow for an assessment of particle and pollutant flux dynamics. In this study, pronounced flood and thus turbidity events were sampled at high temporal resolution in three contrasting catchments in Southwest Germany (Rivers Ammer, Goldersbach, Steinlach) as well as in the River Neckar. Samples were analyzed for turbidity, the total amount of PAH and total suspended solids (TSS) in water. Additionally, the grain size distributions of suspended solids were determined. Discharge and turbidity were measured on-line at gauging stations in three of the catchments. Results showed that turbidity and TSS were linearly correlated over an extended turbidity range up to 2000 NTU for the flood samples (i.e. independent on grain size). This also holds for total PAH concentrations which can be reasonably well predicted based on the turbidity measurements and TSS versus PAH relationships - even for very high turbidity or TSS values (> 2000 NTU or mg l-1, respectively). From these linear regressions concentrations of PAHs on suspended particles were obtained which varied by catchment. The values comprise a robust measure of the average sediment quality in a river network and may be correlated to the degree of urbanization represented by the number of inhabitants per total flux of suspended particles. Based on long-term on-line turbidity measurements mass flow rates of particle bound pollutants over time could be calculated. Results showed that by far the largest amount

  14. Technical Report Series on Global Modeling and Data Assimilation. Volume 42; Soil Moisture Active Passive (SMAP) Project Calibration and Validation for the L4_C Beta-Release Data Product

    NASA Technical Reports Server (NTRS)

    Koster, Randal D. (Editor); Kimball, John S.; Jones, Lucas A.; Glassy, Joseph; Stavros, E. Natasha; Madani, Nima (Editor); Reichle, Rolf H.; Jackson, Thomas; Colliander, Andreas

    2015-01-01

    During the post-launch Cal/Val Phase of SMAP there are two objectives for each science product team: 1) calibrate, verify, and improve the performance of the science algorithms, and 2) validate accuracies of the science data products as specified in the L1 science requirements according to the Cal/Val timeline. This report provides analysis and assessment of the SMAP Level 4 Carbon (L4_C) product specifically for the beta release. The beta-release version of the SMAP L4_C algorithms utilizes a terrestrial carbon flux model informed by SMAP soil moisture inputs along with optical remote sensing (e.g. MODIS) vegetation indices and other ancillary biophysical data to estimate global daily NEE and component carbon fluxes, particularly vegetation gross primary production (GPP) and ecosystem respiration (Reco). Other L4_C product elements include surface (<10 cm depth) soil organic carbon (SOC) stocks and associated environmental constraints to these processes, including soil moisture and landscape FT controls on GPP and Reco (Kimball et al. 2012). The L4_C product encapsulates SMAP carbon cycle science objectives by: 1) providing a direct link between terrestrial carbon fluxes and underlying freeze/thaw and soil moisture constraints to these processes, 2) documenting primary connections between terrestrial water, energy and carbon cycles, and 3) improving understanding of terrestrial carbon sink activity in northern ecosystems.

  15. Beta decay of neutron-rich Co: Probing single-particle states at and above the N=40 subshell closure

    SciTech Connect

    Mueller, W. F.; Bruyneel, B.; Franchoo, S.; Huyse, M.; Kruglov, K.; Kudryavtsev, Y.; Raabe, R.; Reusen, I.; Duppen, P. van; Roosbroeck, J. van; Vermeeren, L.; Weissman, L.; Woehr, A.; Koester, U.; Kratz, K.-L.; Pfeiffer, B.; Thirolf, P.; Walters, W. B.

    1999-09-02

    Neutron-rich Co nuclei with A=66-70 were produced by the laser-ionization isotope-separation on-line method. The {beta} decay from these nuclei has been studied. A case example is given by reporting on the observed decay scheme of {sup 68}Co. The half life of the ground-state decay of this nucleus was measured to be 0.21(3) seconds. In addition, a new {beta} decaying isomer half life of 1.16(25) seconds was discovered. The level scheme of {sup 68}Ni has been significantly extended, and an interpretation of the observed levels is made by assuming that the N=40 gap has the characteristics of a shell closure.

  16. Recent analysis of magnetic field and beta particle measurements of the Starfish nuclear burst plasma expansion and collapse.

    NASA Astrophysics Data System (ADS)

    Dyal, P.

    2004-12-01

    Five spacecraft located 100 to 1000 kilometers around the Starfish nuclear burst measured the expansion and collapse of the plasma bubble produced in the geomagnetic field and early time injection into the inner Van Allen radiation belt. The bubble evolved into an elongated shape 2400 km along the magnetic field lines and 700 km across in 1.2 seconds and required approximately 15 seconds to collapse. After the magnetic bubble reached its maximum size instabilities and fluting permitted the beta emitting fission fragments to continue to expand. This process injected a flux measuring 2.5x1010 beta/cm2sec into the most intense region of the artificial belt mapped by the Injun I spacecraft 10 hours later.

  17. Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs

    NASA Astrophysics Data System (ADS)

    Okeme, Joseph O.; Saini, Amandeep; Yang, Congqiao; Zhu, Jiping; Smedes, Foppe; Klánová, Jana; Diamond, Miriam L.

    2016-10-01

    Polydimethylsiloxane (PDMS) has seen wide use as the stationary phase of gas chromatographic columns, a passive sampler in water, and recently as a personal exposure sampler, while styrene divinyl-benzene copolymer (XAD) has been used extensively as a passive air sampler outdoors and indoors. We have introduced PDMS and XAD-Pocket as new indoor passive air samplers (PASs). The XAD-Pocket was designed to maximize the surface area-to-volume ratio of XAD and to minimize obstruction of air flow by the sampler housing. Methods were developed to expedite the use of these PASs for measuring phthalates, novel brominated flame-retardants (NFRs) and polybrominated diphenyl ethers (PBDEs) indoors. Sampling rates, Rs, (m3 day-1), were measured during a 7-week calibration study. Variability within and between analyte groups was not statistically significant. As a result, generic values of 0.8 ± 0.4 and 0.5 ± 0.3 m3 day-1 dm-2 are recommended for PDMS and XAD-Pocket for a 50-day deployment time, respectively. PDMS has a higher uptake rate and is easier to use than XAD-Pocket.

  18. Beta particle detection efficiency of the radiation sensor made from a mixture of polyaniline and titanium oxide

    NASA Astrophysics Data System (ADS)

    Tamura, M.; Miyata, H.; Katsumata, M.; Matsuda, K.; Ueno, T.; Ito, D.; Suzuki, T.

    2016-08-01

    We developed a new real-time radiation sensor using an organic semiconductor and measured its β-particle detection sensitivity. This sensor is fabricated by simply combining a p-type semiconductor, polyaniline (Pani), with an n-type semiconductor, TiO2, and processing the compound. Since Pani and TiO2 are both inexpensive materials, the sensor can be fabricated at a lower cost than inorganic semiconductor sensors. The signal of each fabricated sensor was measured by a charge sensitive ADC for the irradiation of β-particles. The response signal data of the ADC for each irradiation was measured to calculate the detection efficiency of the detector. The maximum detection efficiency measured as β-particle sensitivity of the sensor was 1%. This β-particle sensitivity is higher than that reported of Pani sensors in the past.

  19. Effects of 17Beta-estradiol on cognitive performance of ovariectomized female rats exposed to 56Fe particles

    Technology Transfer Automated Retrieval System (TEKTRAN)

    On exploratory class missions to other planets astronauts will be exposed to types and doses of radiation (HZE particles) that are not experienced in low earth orbit. While it is likely that the crew will consist of both male and female astronauts, there has been little research on the effects of ...

  20. Improvements to the on-line mass separator, RAMA, and the beta-delayed charged-particle emission of proton-rich sd shell nuclei

    SciTech Connect

    Ognibene, T.J.

    1996-03-01

    To overcome the extreme difficulties encountered in the experimental decay studies of proton drip line nuclei, several techniques have been utilized, including a helium-jet transport system, particle identification detectors and mass separation. Improvements to the ion source/extraction region of the He-jet coupled on-line Recoil Atom Mass Analyzer (RAMA) and its target/ion source coupling resulted in significant increases in RAMA efficiencies and its mass resolution, as well as reductions in the overall transit time. At the 88-Inch Cyclotron at LBNL, the decays of {sup 31}Cl, {sup 27}P and {sup 28}P, with half-lives of 150 msec, 260 msec and 270.3 msec, respectively, were examined using a he-jet and low-energy gas {Delta}E-gas {Delta}E-silicon E detector telescopes. Total beta-delayed proton branches of 0.3% and 0.07% in {sup 31}Cl and {sub 27}P, respectively, were estimated. Several proton peaks that had been previously assigned to the decay of {sup 31}Cl were shown to be from the decay of {sup 25}Si. In {sup 27}P, two proton groups at 459 {+-} 14 keV and 610 {+-} 11 keV, with intensities of 7 {+-} 3% and 92 {+-} 4% relative to the main (100%) group were discovered. The Gamow-Teller component of the preceding beta-decay of each observed proton transition was compared to results from shell model calculations. Finally, a new proton transition was identified, following the {beta}-decay of {sup 28}P, at 1,444 {+-} 12 keV with a 1.7 {+-} 0.5% relative intensity to the 100% group. Using similar low-energy detector telescopes and the mass separator TISOL at TRIUMF, the 109 msec and 173 msec activities, {sup 17}Ne and {sup 33}Ar, were studied. A new proton group with energy 729 {+-} 15 keV was observed following the beta-decay of {sup 17}Ne. Several discrepancies between earlier works as to the energies, intensities and assignments of several proton transitions from {sup 17}Ne and {sup 33}Ar were resolved.

  1. Reconnection in the Heliosheath: Effects of Plasma Beta on Particle Acceleration and the Shape of Magnetic Islands

    NASA Astrophysics Data System (ADS)

    Schoeffler, K. M.; Drake, J. F.; Swisdak, M. M.

    2011-12-01

    In the heliosheath it has been predicted that current sheets are compressed and break up into magnetic islands or bubbles. The interaction of particles in these islands via the Fermi process in contracting islands has been predicted to be a source of anomalous cosmic rays (ACRs). The plasma β (the ratio of the plasma pressure to the magnetic pressure) can have a large range of values in this region. We investigate the effects of β on the formation of islands, and of the acceleration of particles as these magnetic islands form. Using a particle-in-cell code, we simulate island growth in multiple interacting Harris current sheets. We produce different values of β by changing the temperature of a background population. We find that for higher β significantly more elongated islands are formed. More modestly elongated islands are suppressed by pressure anisotropy approaching the marginal firehose condition. Measurements from the Voyager spacecrafts are consistent with these long islands. We also find significantly less electron acceleration as β increases, while the ions are mostly unaffected. Scattering of the electrons in high β systems (β > 1) halts the Fermi process while the ions continue to be accelerated.

  2. Field evaluation and calibration of a small axial passive air sampler for gaseous and particle bound polycyclic aromatic hydrocarbons (PAHs) and oxygenated PAHs.

    PubMed

    Magnusson, Roger; Arnoldsson, Kristina; Lejon, Christian; Hägglund, Lars; Wingfors, Håkan

    2016-09-01

    Polycyclic aromatic hydrocarbons (PAHs) and their oxygenated analogues (OPAHs) are ubiquitous air pollutants known to cause adverse health effects. PAH air levels are commonly monitored by active sampling but passive sampling has become popular because of its lower cost and simplicity, which facilitate long-term sampling and increased spatial coverage. However, passive samplers are less suitable for short-term sampling and are in general less accurate than active samplers because they require reliable sampling rate (Rs) measurements for individual analytes under diverse environmental conditions. In this study a small passive sampler designed to sample both particle-bound and gaseous compounds was evaluated and calibrated for PAHs and OPAHs in a traffic environment by co-deployment with active samplers for two weeks. Despite the relatively low average air concentrations of PM10 (20 μg/m(3)), PM2.5 (5 μg/m(3)), total PAHs (4.2 ng/m(3)), and OPAHs (2.3 ng/m(3)) at the site, detectable quantities (on average 24 times above blank values) of the full range of PAHs and OPAHs were captured, with low variability (average RSD of 16%). This was accomplished by using a Tenax(®) TA-modified glass fiber substrate that is compatible with highly sensitive thermal desorption GC-MS analysis, which made it possible to achieve detection limits per sample in the pg range. Experiments with inverted samplers revealed that the relative contribution of gravitational settling to the sampling of particles carrying PAHs and OPAHs was around 3.5 times larger than other deposition mechanisms. Average Rs values for individual OPAHs and PAHs were 0.046 ± 0.03 m(3)/day and 0.12 ± 0.07 m(3)/day, respectively, with no appreciable difference between the values for particle-associated and gaseous compounds. Furthermore, the Rs values were competitive with other currently used passive samplers if normalized for substrate area. Overall, the new sampler's performance, simplicity and

  3. Infantile Refsum disease: deficiency of catalase-containing particles (peroxisomes), alkyldihydroxyacetone phosphate synthase and peroxisomal beta-oxidation enzyme proteins.

    PubMed

    Wanders, R J; Schutgens, R B; Schrakamp, G; van den Bosch, H; Tager, J M; Schram, A W; Hashimoto, T; Poll-Thé, B T; Saudubrau, J M

    1986-08-01

    In recent years a number of biochemical abnormalities have been described in patients with the infantile form of Refsum disease, including the accumulation of very long chain fatty acids, trihydroxycoprostanoic acid and pipecolic acid. In this paper we show that catalase-containing particles (peroxisomes), alkyl dihydroxyacetone phosphate synthase and acyl-CoA oxidase protein are deficient in patients with infantile Refsum disease. These findings suggest that in the infantile form of Refsum disease, as in the cerebro-hepato-renal (Zellweger) syndrome the multiplicity of biochemical abnormalities is due to a deficiency of peroxisomes and hence to a generalized loss of peroxisomal functions. As a consequence the infantile form of Refsum disease can be diagnosed biochemically by methods already available for the prenatal and postnatal diagnosis of the cerebro-hepato-renal (Zellweger) syndrome.

  4. Neutrinoless double beta decay and neutrino masses

    SciTech Connect

    Duerr, Michael

    2012-07-27

    Neutrinoless double beta decay (0{nu}{beta}{beta}) is a promising test for lepton number violating physics beyond the standard model (SM) of particle physics. There is a deep connection between this decay and the phenomenon of neutrino masses. In particular, we will discuss the relation between 0{nu}{beta}{beta} and Majorana neutrino masses provided by the so-called Schechter-Valle theorem in a quantitative way. Furthermore, we will present an experimental cross check to discriminate 0{nu}{beta}{beta} from unknown nuclear background using only one isotope, i.e., within one experiment.

  5. Anemometer calibrator

    NASA Technical Reports Server (NTRS)

    Bate, T.; Calkins, D. E.; Price, P.; Veikins, O.

    1971-01-01

    Calibrator generates accurate flow velocities over wide range of gas pressure, temperature, and composition. Both pressure and flow velocity can be maintained within 0.25 percent. Instrument is essentially closed loop hydraulic system containing positive displacement drive.

  6. An alternative calibration method for counting P-32 reactor monitors

    SciTech Connect

    Quirk, T.J.; Vehar, D.W.

    2011-07-01

    Radioactivation of sulfur is a common technique used to measure fast neutron fluences in test and research reactors. Elemental sulfur can be pressed into pellets and used as monitors. The {sup 32}S(n, p) {sup 32}P reaction has a practical threshold of about 3 MeV and its cross section and associated uncertainties are well characterized [1]. The product {sup 32P} emits a beta particle with a maximum energy of 1710 keV [2]. This energetic beta particle allows pellets to be counted intact. ASTM Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32 (E265) [3] details a method of calibration for counting systems and subsequent analysis of results. This method requires irradiation of sulfur monitors in a fast-neutron field whose spectrum and intensity are well known. The resultant decay-corrected count rate is then correlated to the known fast neutron fluence. The Radiation Metrology Laboratory (RML) at Sandia has traditionally performed calibration irradiations of sulfur pellets using the {sup 252}Cf spontaneous fission neutron source at the National Inst. of Standards and Technology (NIST) [4] as a transfer standard. However, decay has reduced the intensity of NIST's source; thus lowering the practical upper limits of available fluence. As of May 2010, neutron emission rates have decayed to approximately 3 e8 n/s. In practice, this degradation of capabilities precludes calibrations at the highest fluence levels produced at test reactors and limits the useful range of count rates that can be measured. Furthermore, the reduced availability of replacement {sup 252}Cf threatens the long-term viability of the NIST {sup 252}Cf facility for sulfur pellet calibrations. In lieu of correlating count rate to neutron fluence in a reference field the total quantity of {sup 32}P produced in a pellet can be determined by absolute counting methods. This offers an attractive alternative to extended {sup 252}Cf exposures because it

  7. Determination of isoprene and alpha-/beta-pinene oxidation products in boreal forest aerosols from Hyytiälä, Finland: diel variations and possible link with particle formation events.

    PubMed

    Kourtchev, I; Ruuskanen, T M; Keronen, P; Sogacheva, L; Dal Maso, M; Reissell, A; Chi, X; Vermeylen, R; Kulmala, M; Maenhaut, W; Claeys, M

    2008-01-01

    Biogenic volatile organic compounds (VOCs), such as isoprene and alpha-/beta-pinene, are photo-oxidized in the atmosphere to non-volatile species resulting in secondary organic aerosol (SOA). The goal of this study was to examine time trends and diel variations of oxidation products of isoprene and alpha-/beta-pinene in order to investigate whether they are linked with meteorological parameters or trace gases. Separate day-night aerosol samples (PM(1)) were collected in a Scots pine dominated forest in southern Finland during 28 July-11 August 2005 and analyzed with gas chromatography/mass spectrometry (GC/MS). In addition, inorganic trace gases (SO(2), CO, NO(x), and O(3)), meteorological parameters, and the particle number concentration were monitored. The median total concentration of terpenoic acids (i.e., pinic acid, norpinic acid, and two novel compounds, 3-hydroxyglutaric acid and 2-hydroxy-4-isopropyladipic acid) was 65 ng m(-3), while that of isoprene oxidation products (i.e., 2-methyltetrols and C(5) alkene triols) was 17.2 ng m(-3). The 2-methyltetrols exhibited day/night variations with maxima during day-time, while alpha-/beta-pinene oxidation products did not show any diel variation. The sampling period was marked by a relatively high condensation sink, caused by pre-existing aerosol particles, and no nucleation events. In general, the concentration trends of the SOA compounds reflected those of the inorganic trace gases, meteorological parameters, and condensation sink. Both the isoprene and alpha-/beta-pinene SOA products were strongly influenced by SO(2), which is consistent with earlier reports that acidity plays a role in SOA formation. The results support previous proposals that oxygenated VOCs contribute to particle growth processes above boreal forest.

  8. ALTEA: The instrument calibration

    NASA Astrophysics Data System (ADS)

    Zaconte, V.; Belli, F.; Bidoli, V.; Casolino, M.; di Fino, L.; Narici, L.; Picozza, P.; Rinaldi, A.; Sannita, W. G.; Finetti, N.; Nurzia, G.; Rantucci, E.; Scrimaglio, R.; Segreto, E.; Schardt, D.

    2008-05-01

    The ALTEA program is an international and multi-disciplinary project aimed at studying particle radiation in space environment and its effects on astronauts’ brain functions, as the anomalous perception of light flashes first reported during Apollo missions. The ALTEA space facility includes a 6-silicon telescopes particle detector, and is onboard the International Space Station (ISS) since July 2006. In this paper, the detector calibration at the heavy-ion synchrotron SIS18 at GSI Darmstadt will be presented and compared to the Geant 3 Monte Carlo simulation. Finally, the results of a neural network analysis that was used for ion discrimination on fragmentation data will also be presented.

  9. Image Calibration

    NASA Technical Reports Server (NTRS)

    Peay, Christopher S.; Palacios, David M.

    2011-01-01

    Calibrate_Image calibrates images obtained from focal plane arrays so that the output image more accurately represents the observed scene. The function takes as input a degraded image along with a flat field image and a dark frame image produced by the focal plane array and outputs a corrected image. The three most prominent sources of image degradation are corrected for: dark current accumulation, gain non-uniformity across the focal plane array, and hot and/or dead pixels in the array. In the corrected output image the dark current is subtracted, the gain variation is equalized, and values for hot and dead pixels are estimated, using bicubic interpolation techniques.

  10. Flow Calibration

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Flow Technology Inc. worked with Lewis Research Center to develop a system for monitoring two different propellants being supplied to a spacecraft rocket thruster. They then commercialized the technology in the Microtrack, an extremely precise low-flow calibration system. Moog Inc., one of the device's primary users, measures the flow rate or the speed at which hydraulic oil flows through pin sized holes in disc shaped sapphires with the Microtrack. Using this data, two orifices with exactly the same flow rate can be matched as a pair and used as masters in servovalve production. The microtrack can also be used to calibrate other equipment.

  11. Determining orbital particle parameters of impacts into germanium using morphology analysis and calibration data from hypervelocity impact experiments in the laboratory

    NASA Technical Reports Server (NTRS)

    Paul, Klaus G.

    1995-01-01

    This paper describes the work that is done at the Lehrstuhl fur Raumfahrttechnik (lrt) at the Technische Universitat Munchen to examine particle impacts into germanium surfaces which were flown on board the LDEF satellite. Besides the description of the processing of the samples, a brief overview of the particle launchers at our institute is given together with descriptions of impact morphology of high- and hypervelocity particles into germanium. Since germanium is a brittle, almost glass-like material, the impact morphology may also be interesting for anyone dealing with materials such as optics and solar cells. The main focus of our investigations is to learn about the impacting particle's properties, for example mass, velocity and direction. This is done by examining the morphology, various geometry parameters, crater obliqueness and crater volume.

  12. Model Calibration and Optics Correction Using Orbit Response Matrix in the Fermilab Booster

    SciTech Connect

    Lebedev, V.A.; Prebys, E.; Petrenko, A.V.; Kopp, S.E.; McAteer, M.J.; /Texas U.

    2012-05-01

    We have calibrated the lattice model and measured the beta and dispersion functions in Fermilab's fast-ramping Booster synchrotron using the Linear Optics from Closed Orbit (LOCO) method. We used the calibrated model to implement ramped coupling, dispersion, and beta-beating corrections throughout the acceleration cycle, reducing horizontal beta beating from its initial magnitude of {approx}30% to {approx}10%, and essentially eliminating vertical beta-beating and transverse coupling.

  13. Detection of alpha radiation in a beta radiation field

    DOEpatents

    Mohagheghi, Amir H.; Reese, Robert P.

    2001-01-01

    An apparatus and method for detecting alpha particles in the presence of high activities of beta particles utilizing an alpha spectrometer. The apparatus of the present invention utilizes a magnetic field applied around the sample in an alpha spectrometer to deflect the beta particles from the sample prior to reaching the detector, thus permitting detection of low concentrations of alpha particles. In the method of the invention, the strength of magnetic field required to adequately deflect the beta particles and permit alpha particle detection is given by an algorithm that controls the field strength as a function of sample beta energy and the distance of the sample to the detector.

  14. Use of particle tracking to improve numerical model calibration and to analyze ground-water flow and contaminant migration, Massachusetts Military Reservation, western Cape Cod, Massachusetts

    USGS Publications Warehouse

    Masterson, John P.; Walter, Donald A.; Savoie, Jennifer G.

    1997-01-01

    A steady-state, three-dimensional flow model coupled with a particle-tracking algorithm was developed to assess the complex interaction of hydrogeologic conditions affecting ground-water flow and contaminant transport--including aquifer heterogeneities, hydrologic boundaries such as ponds and streams, ground-water withdrawals, and aquifer recharge to characterize the migration of contaminants emanating from beneath the Massachusetts Military Reservation, Cape Cod, Massachusetts. The known extent of contaminant plumes were used to assess the effects of changes in model input parameters on model-calculated water-table and pond altitudes, streamflow, and water-particle pathlines. Although changes in selected simulated hydrogeologic conditions resulted in minor changes in model-calculated water-table altitudes, pond altitudes, and streamflow, these changes had significant effects on the projection of model-calculated water-particle pathlines.

  15. Quantification of particle sizes with metal replication under standard freeze-etching conditions: a gold ball standard for calibrating shadow widths was used to measure freeze-etched globular proteins.

    PubMed

    Ruben, G C

    1995-11-01

    The real size of platinum-carbon (Pt-C) replicated particles is not directly equivalent to either its metal-coated diameter or its shadow width. This paper describes two indirect methods, shadow widths and coated particle diameters, for determining a particle's actual size beneath a Pt-C replication film. Both produce equivalent measurements using the same standardized conditions: 2.3 nm Pt-C films deposited at a 45 degree angle on an approximately -100 degrees C surface in a 10(-6) torr vacuum. For the first method, gold balls nucleated in a partial pressure of helium and deposited on flat indirect carbon films (root mean square roughness of 0.8 nm) on 400 mesh grids were used as test particles for calibrating shadow widths as a function of particle size. The gold ball test specimens were replicated, and a distribution of Pt-C shadow widths orthogonal to the Pt-C deposition direction was measured and averaged for gold balls 1.5 +/- 0.25 nm, 2.0 +/- 0.25 nm, etc. The diameter of each gold ball was measured within the Pt-C film along with its shadow width because the Pt-C did not obscure or adhere well to the gold. The shadow width distributions for each gold size do not differ significantly from log normal. Two proteins, the lactose repressor and the mitochondrial ATPase, F1, were also used as replication test objects. Negative staining of both proteins was conducted to measure their average diameters. In the second method, a distribution of Pt-C-coated lac repressor diameters perpendicular to the shadow direction was measured. The Pt-C film thickness measured on the quartz crystal monitor was subtracted from the average metal-coated protein diameter to obtain the lac repressor's diameter. The Pt-C-coated particle diameter distributions also did not differ significantly from log normal. While doing this work it was discovered that outgassing the Pt-C electron gun greatly affected Pt-C film granularity: 19 sec produced a high contrast, granular Pt-C film, whereas

  16. Optical calibration of SNO +

    NASA Astrophysics Data System (ADS)

    Leming, Edward; SNO+ Collaboration

    2015-04-01

    Situated 2 km underground in Sudbury, Northern Ontario, the SNO + detector consists of an acrylic sphere 12 m in diameter containing 780 tons of target mass, surrounded by approximately 9,500 PMTs. For SNO, this target mass was heavy water, however the change to SNO + is defined by the change of this target mass to a novel scintillator. With the lower energy threshold, low intrinsic radioactivity levels and the best shielding against muons and cosmogenic activation of all existing neutrino experiments, SNO + will be sensitive to exciting new physics. The experiment will be studying solar, reactor, super nova and geo-neutrinos, though the main purpose of SNO + is the search for neutrinoless double-beta decay of Te-130. To meet the requirements imposed by the physics on detector performance, a detailed optical calibration is needed. Source deployment must be kept to a minimum and eliminated if possible, in order to meet the stringent radiopurity requirements. This led to the development of the Embedded LED/laser Light Injection Entity (ELLIE) system. This talk provides a summary of the upgrades to from SNO to SNO +, discussing the requirements on and methods of optical calibration, focusing on the deployed laserball and ELLIE system.

  17. Monte Carlo N–Particle Transport Code System Including MCNP6.1.1BETA, MCNP6.1, MCNP5-1.60, MCNPX-2.7.0 and Data Libraries.

    2014-09-01

    Version 01 MCNP6™ is a general-purpose, continuous-energy, generalized-geometry, time-dependent, Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. This MCNP6.1.1Beta is a follow-on to the MCNP6.1 production version which itself was the culmination of a multi-year effort to merge the MCNP5™ [X-503] and MCNPX™ [PEL11] codes into a single product. This MCNP6.1.1 beta has been released in order to provide the radiation transport community with the latest feature developmentsmore » and bug fixes in the code. MCNP6.1.1 has taken input from a group of people, residing in the Los Alamos National Laboratory's (LANL) X Computational Physics Division, Radiation Transport Group (XCP-3), and Nuclear Engineering and Nonproliferation Division, Systems Design and Analysis Group (NEN-5). They have combined their code development efforts to produce this next evolution of MCNP. For those familiar with previous versions of MCNP, you will discover the code has been expanded to handle a multitude of particles and to include model physics options for energies above the cross-section table range, a material burnup feature, and delayed particle production. Expanded and/or new tally, source, and variance-reduction options are available to the user as well as an improved plotting capability. The capability to calculate keff eigenvalues for fissile systems remains a standard feature. Although MCNP6 is simply and accurately described as the merger of MCNP5 and MCNPX capabilities, the result is much more than the sum of these two computer codes. MCNP6 is the result of five years of effort by the MCNP5 and MCNPX code development teams.« less

  18. Monte Carlo N–Particle Transport Code System Including MCNP6.1.1BETA, MCNP6.1, MCNP5-1.60, MCNPX-2.7.0 and Data Libraries.

    SciTech Connect

    2014-09-01

    Version 01 MCNP6™ is a general-purpose, continuous-energy, generalized-geometry, time-dependent, Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. This MCNP6.1.1Beta is a follow-on to the MCNP6.1 production version which itself was the culmination of a multi-year effort to merge the MCNP5™ [X-503] and MCNPX™ [PEL11] codes into a single product. This MCNP6.1.1 beta has been released in order to provide the radiation transport community with the latest feature developments and bug fixes in the code. MCNP6.1.1 has taken input from a group of people, residing in the Los Alamos National Laboratory's (LANL) X Computational Physics Division, Radiation Transport Group (XCP-3), and Nuclear Engineering and Nonproliferation Division, Systems Design and Analysis Group (NEN-5). They have combined their code development efforts to produce this next evolution of MCNP. For those familiar with previous versions of MCNP, you will discover the code has been expanded to handle a multitude of particles and to include model physics options for energies above the cross-section table range, a material burnup feature, and delayed particle production. Expanded and/or new tally, source, and variance-reduction options are available to the user as well as an improved plotting capability. The capability to calculate keff eigenvalues for fissile systems remains a standard feature. Although MCNP6 is simply and accurately described as the merger of MCNP5 and MCNPX capabilities, the result is much more than the sum of these two computer codes. MCNP6 is the result of five years of effort by the MCNP5 and MCNPX code development teams.

  19. Beta contamination monitor energy response

    SciTech Connect

    Bjork, C.W.; Olsher, R.H.

    1998-12-31

    Beta contamination is monitored at Los Alamos National Laboratory (LANL) with portable handheld probes and their associated counters, smear counters, air-breathing continuous air monitors (CAM), personnel contamination monitors (PCM), and hand and foot monitors (HFM). The response of these monitors was measured using a set of anodized-aluminum beta sources for the five isotopes: Carbon-14, Technetium-99, Cesium-137, Chlorine-36 and Strontium/Yttrium-90. The surface emission rates of the sources are traceable to the National Institute of Standards and Technology (NIST) with a precision of one relative standard deviation equal to 1.7%. All measurements were made in reproducible geometry, mostly using aluminum source holders. All counts, significantly above background, were collected to a precision of 1% or better. The study of the hand-held probes included measurements of six air gaps from 0.76 to 26.2 mm. The energy response of the detectors is well-parameterized as a function of the average beta energy of the isotopes (C14=50 keV, Tc99=85, Cs137=188, C136=246, and Sr/Y90=934). The authors conclude that Chlorine-36 is a suitable beta emitter for routine calibration. They recommend that a pancake Geiger-Mueller (GM) or gas-proportional counter be used for primarily beta contamination surveys with an air gap not to exceed 6 mm. Energy response varies about 30% from Tc99 to Sr/Y90 for the pancake GM detector. Dual alpha/beta probes have poor to negligible efficiency for low-energy betas. The rugged anodized sources represent partially imbedded contamination found in the field and they are provided with precise, NIST-traceable, emission rates for reliable calibration.

  20. A measurement of the beta spectrum of 63Ni using a new type of cryogenic detector

    NASA Astrophysics Data System (ADS)

    Gaistkell, R. J.; Angrave, L. C.; Booth, N. E.; Hahn, A. D.; Salmon, G. L.; Swift, A. M.

    1996-02-01

    A precision measurement of the beta spectrum of 63Ni has been performed using a new type of cryogenic particle detector. This is the first nuclear physics experiment using this technique, and we discuss the principles of the method, its advantages and its shortcomings. Careful studies of detector stability, calibration, pulse pile-up and systematics have made it possible to collect large numbers of events (∼ 10 8) over long periods (∼ 28 days). The measurement is consistent with no 17 keV/c 2 neutrino admixture, giving a preferred value of (-0.05 ± 0.31)%.

  1. SMAP RADAR Calibration and Validation

    NASA Astrophysics Data System (ADS)

    West, R. D.; Jaruwatanadilok, S.; Chaubel, M. J.; Spencer, M.; Chan, S. F.; Chen, C. W.; Fore, A.

    2015-12-01

    The Soil Moisture Active Passive (SMAP) mission launched on Jan 31, 2015. The mission employs L-band radar and radiometer measurements to estimate soil moisture with 4% volumetric accuracy at a resolution of 10 km, and freeze-thaw state at a resolution of 1-3 km. Immediately following launch, there was a three month instrument checkout period, followed by six months of level 1 (L1) calibration and validation. In this presentation, we will discuss the calibration and validation activities and results for the L1 radar data. Early SMAP radar data were used to check commanded timing parameters, and to work out issues in the low- and high-resolution radar processors. From April 3-13 the radar collected receive only mode data to conduct a survey of RFI sources. Analysis of the RFI environment led to a preferred operating frequency. The RFI survey data were also used to validate noise subtraction and scaling operations in the radar processors. Normal radar operations resumed on April 13. All radar data were examined closely for image quality and calibration issues which led to improvements in the radar data products for the beta release at the end of July. Radar data were used to determine and correct for small biases in the reported spacecraft attitude. Geo-location was validated against coastline positions and the known positions of corner reflectors. Residual errors at the time of the beta release are about 350 m. Intra-swath biases in the high-resolution backscatter images are reduced to less than 0.3 dB for all polarizations. Radiometric cross-calibration with Aquarius was performed using areas of the Amazon rain forest. Cross-calibration was also examined using ocean data from the low-resolution processor and comparing with the Aquarius wind model function. Using all a-priori calibration constants provided good results with co-polarized measurements matching to better than 1 dB, and cross-polarized measurements matching to about 1 dB in the beta release. During the

  2. Studies of polarization bremsstrahlung and ordinary bremsstrahlung from 89Sr beta particles in metallic targets in the photon energy region of 1-100 keV

    NASA Astrophysics Data System (ADS)

    Singh, Amrit; Dhaliwal, A. S.

    2015-06-01

    Studies of polarization bremsstrahlung (PB) and ordinary bremsstrahlung (OB) produced by the 89Sr beta emitter in Al, Ti, Sn and Pb targets were undertaken at photon energies of 1-100 keV. The experimental results are compared with the Elwert corrected (non-relativistic) Bethe-Heitler (EBH) theory and the modified Elwert factor (relativistic) Bethe-Heitler (Fmod BH) theory for OB and with the Avdonina and Pratt (Fmod BH + PB) theory for total bremsstrahlung (BS). These results are in agreement with the Fmod BH + PB theory up to 13 keV, 16 keV, 22 keV and 28 keV energies for Al, Ti, Sn and Pb targets, respectively; Fmod BH theory is more accurate at higher energies.

  3. Muon Energy Calibration of the MINOS Detectors

    SciTech Connect

    Miyagawa, Paul S.

    2004-09-01

    MINOS is a long-baseline neutrino oscillation experiment designed to search for conclusive evidence of neutrino oscillations and to measure the oscillation parameters precisely. MINOS comprises two iron tracking calorimeters located at Fermilab and Soudan. The Calibration Detector at CERN is a third MINOS detector used as part of the detector response calibration programme. A correct energy calibration between these detectors is crucial for the accurate measurement of oscillation parameters. This thesis presents a calibration developed to produce a uniform response within a detector using cosmic muons. Reconstruction of tracks in cosmic ray data is discussed. This data is utilized to calculate calibration constants for each readout channel of the Calibration Detector. These constants have an average statistical error of 1.8%. The consistency of the constants is demonstrated both within a single run and between runs separated by a few days. Results are presented from applying the calibration to test beam particles measured by the Calibration Detector. The responses are calibrated to within 1.8% systematic error. The potential impact of the calibration on the measurement of oscillation parameters by MINOS is also investigated. Applying the calibration reduces the errors in the measured parameters by {approx} 10%, which is equivalent to increasing the amount of data by 20%.

  4. Beta Decay Study of Neutron-rich Magnesium

    NASA Astrophysics Data System (ADS)

    Ash, John; Rajabali, Mustafa; Griffin Collaboration

    2015-10-01

    Within the ``island of inversion'' around the N = 20 shell gap, isotopes of magnesium, and aluminum deviate from the expected closed-shell structure. Particles promoted across the N = 20 shell gap result in a lower energy deformed ground state configuration rather than the expected spherical configuration. An experiment was conducted at TRIUMF laboratory in the summer of 2015 to study the decay of ``island of inversion'' isotopes 33 , 34 , 35Mg and the structure of the respective daughter nuclei. The isotopes of interest were produced by a proton beam from TRIUMF's 500 MeV cyclotron impacting on a UCx target. The magnesium decays populated states along the decay chain in Al, Si, P, and S isotopes. The new GRIFFIN spectrometer in the ISAC-I facility was used to detect the gamma rays. Two sets of scintillators, one for detecting the beta particles (SCEPTAR) and the other for detecting beta-delayed neutrons (DESCANT), were also used in conjunction with GRIFFIN. The GRIFFIN data were energy calibrated and partially analyzed for this project. New algorithms were developed for the analysis. Preliminary results for new transitions detected in 34Mg as well as the half lives obtained will be presented in their current form. This research was supported by the Tennessee Tech research office.

  5. Dynamic radioactive particle source

    DOEpatents

    Moore, Murray E.; Gauss, Adam Benjamin; Justus, Alan Lawrence

    2012-06-26

    A method and apparatus for providing a timed, synchronized dynamic alpha or beta particle source for testing the response of continuous air monitors (CAMs) for airborne alpha or beta emitters is provided. The method includes providing a radioactive source; placing the radioactive source inside the detection volume of a CAM; and introducing an alpha or beta-emitting isotope while the CAM is in a normal functioning mode.

  6. Cherenkov Source for PMT Calibrations

    NASA Astrophysics Data System (ADS)

    Kaptanoglu, Tanner; SNO+ at UC Berkeley Collaboration

    2013-10-01

    My research is focused on building a deployable source for PMT calibrations in the SNO+ detector. I work for the SNO+ group at UC Berkeley headed by Gabriel Orebi Gann. SNO+ is an addition to the SNO project, and its main goal is to search for neutrinoless double beta decay. The detector will be monitored by over 9500 photomultiplier tubes (PMTs). In order to characterize the PMTs, several calibration sources are being constructed. One of which, the Cherenkov Source, will provide a well-understood source of non-isotropic light for calibrating the detector response. My goal is to design and construct multiple aspects of the Cherenkov Source. However, there are multiple questions that arose with its design. How do we keep the scintillation light inside the Cherenkov source so it does not contaminate calibration? How do we properly build the Cherenkov source: a hollow acrylic sphere with a neck? Can we maintain a clean source throughout these processes? These are some of the problems I have been working on, and will continue to work on, until the deployment of the source. Additionally, I have worked to accurately simulate the physics inside the source, mainly the energy deposition of alphas.

  7. Calibration of sound calibrators: an overview

    NASA Astrophysics Data System (ADS)

    Milhomem, T. A. B.; Soares, Z. M. D.

    2016-07-01

    This paper presents an overview of calibration of sound calibrators. Initially, traditional calibration methods are presented. Following, the international standard IEC 60942 is discussed emphasizing parameters, target measurement uncertainty and criteria for conformance to the requirements of the standard. Last, Regional Metrology Organizations comparisons are summarized.

  8. Response of ionization chamber based pocket dosimeter to beta radiation.

    PubMed

    Kumar, Munish; Gupta, Anil; Pradhan, S M; Bakshi, A K; Chougaonkar, M P; Babu, D A R

    2013-12-01

    Quantitative estimate of the response of ionization chamber based pocket dosimeters (DRDs) to various beta sources was performed. It has been established that the ionization chamber based pocket dosimeters do not respond to beta particles having energy (Emax)<1 MeV and same was verified using (147)Pm, (85)Kr and (204)Tl beta sources. However, for beta particles having energy >1 MeV, the DRDs exhibit measureable response and the values are ~8%, ~14% and ~27% per mSv for natural uranium, (90)Sr/(90)Y and (106)Ru/(106)Rh beta sources respectively. As the energy of the beta particles increases, the response also increases. The response of DRDs to beta particles having energy>1 MeV arises due to the fact that the thickness of the chamber walls is less than the maximum range of beta particles. This may also be one of the reasons for disparity between doses measured with passive/legal dosimeters (TLDs) and DRDs in those situations in which radiation workers are exposed to mixed field of gamma photons and beta particles especially at uranium processing plants, nuclear (power and research) reactors, waste management facilities and fuel reprocessing plants etc. The paper provides the reason (technical) for disparity between the doses recorded by TLDs and DRDs in mixed field of photons and beta particles.

  9. Bremsstrahlung in Mo and Pt targets produced by {sup 90}Sr beta particles in the photon energy region of 1-100 keV

    SciTech Connect

    Singh, Amrit; Dhaliwal, A. S.

    2015-08-28

    Bremsstrahlung spectra in thick targets of Mo and Pt, produced by beta emitter {sup 90}Sr (end point energy = 546 keV) have been studied in the photon energy range of 1-100 keV. The experimentally measured bremsstrahlung spectra measured with Si(Li) detector were compared with the theoretical spectral distributions calculated from Elwert corrected (non relativistic) Bethe-Heitler [EBH] theory, modified Elwert factor (relativistic) Bethe-Heitler (F{sub mod}BH) theory for ordinary bremsstrahlung (OB) and the modified Elwert factor (relativistic) Bethe-Heitler (F{sub mod}BH+PB) theory, which includes the polarization bremsstrahlung (PB) into total bremsstrahlung (BS). The present results indicate the correctness of F{sub mod}BH+PB theory in the low energy region, where the contributions of PB into BS are dominant, which is described in terms of stripped atom (SA) approximation. But at the middle and higher energy region of the bremsstrahlung spectrum, where the contribution of PB is negligible, the F{sub mod}BH theory is more close to the experimental results. Hence, it is clear that the production of PB in the low energy region, due to the dynamic response of the target atom suppresses the production of bremsstrahlung at higher energy ends.

  10. Chemical Imaging of Catalyst Deactivation during the Conversion of Renewables at the Single Particle Level: The Etherification of Biomass-based Polyols with Alkenes over H-Beta Zeolites

    SciTech Connect

    A Parvulescu; D Mores; E Stavitski; C Teodorescu; P Bruijnicx; R Klein Gebbing; B Weckhuysen

    2011-12-31

    The etherification of biomass-based alcohols with various linear {alpha}-olefins under solvent-free conditions was followed in a space- and time-resolved manner on 9 {micro}m large H-Beta zeolite crystals by confocal fluorescence microscopy. This allowed us to visualize the interaction with the substrate and distribution of the coke products into the catalyst at the level of an individual zeolite crystal during the etherification process. The spectroscopic information obtained on the micrometer-scale zeolite was in line with the results obtained with bulk characterization techniques and further confirmed by the catalytic results obtained both for micrometer-scale and nanoscale zeolites. This allowed us to explain the influence of the substrate type (glycerol, glycols, and alkenes) and zeolite properties (Si/Al ratio and particle size) on the etherification activity. The etherification of the biomass-based alcohols takes place mainly on the external surface of the zeolite particles. The gradual blockage of the external surface of the zeolite results in a partial or total loss of etherification activity. The deactivation could be attributed to olefin oligomerization. The high conversions obtained in the etherification of 1,2-propylene glycol with long linear alkenes (up to 80%) and the pronounced deactivation of the zeolite observed in the etherification of glycerol with long linear alkenes (max. 20% conversion) were explained by the spectroscopic measurements and is due to differences in the adsorption, i.e., in the center of the zeolite particle for glycerol and on the external surface in the case of glycols.

  11. Beta cell device using icosahedral boride compounds

    DOEpatents

    Aselage, Terrence L.; Emin, David

    2002-01-01

    A beta cell for converting beta-particle energies into electrical energy having a semiconductor junction that incorporates an icosahedral boride compound selected from B.sub.12 As.sub.2, B.sub.12 P.sub.2, elemental boron having an .alpha.-rhombohedral structure, elemental boron having a .beta.-rhombohedral structure, and boron carbides of the chemical formula B.sub.12-x C.sub.3-x, where 0.15beta radiation source, and means for transmitting electrical energy to an outside load. The icosahedral boride compound self-heals, resisting degradation from radiation damage.

  12. Beta systems error analysis

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The atmospheric backscatter coefficient, beta, measured with an airborne CO Laser Doppler Velocimeter (LDV) system operating in a continuous wave, focussed model is discussed. The Single Particle Mode (SPM) algorithm, was developed from concept through analysis of an extensive amount of data obtained with the system on board a NASA aircraft. The SPM algorithm is intended to be employed in situations where one particle at a time appears in the sensitive volume of the LDV. In addition to giving the backscatter coefficient, the SPM algorithm also produces as intermediate results the aerosol density and the aerosol backscatter cross section distribution. A second method, which measures only the atmospheric backscatter coefficient, is called the Volume Mode (VM) and was simultaneously employed. The results of these two methods differed by slightly less than an order of magnitude. The measurement uncertainties or other errors in the results of the two methods are examined.

  13. Beta Blockers

    PubMed Central

    Admani, Shehla; Feldstein, Stephanie; Gonzalez, Ernesto M.

    2014-01-01

    Infantile hemangiomas are benign vascular tumors seen in 4.5 percent of neonates and infants. While most infantile hemangiomas can be managed with active nonintervention, a subset of patients will require more aggressive management. Here the authors review the use of beta-blockers in the treatment of infantile hemangiomas, including oral, topical, and multimodal treatment options. They discuss the latest data on propranolol, including criteria for patient selection, dosing recommendations, and appropriate monitoring for side effects and efficacy. Lastly, they review indications for topical timolol treatment and the potential benefits of concomitant laser therapy. PMID:25053982

  14. Modeling Study of a Proposed Field Calibration Source Using K-40 and High-Z Targets for Sodium Iodide Detectors.

    PubMed

    Rogers, Jeremy; Marianno, Craig; Kallenbach, Gene; Trevino, Jose

    2016-06-01

    Calibration sources based on the primordial isotope potassium-40 (K) have reduced controls on the source's activity due to its terrestrial ubiquity and very low specific activity. Potassium-40's beta emissions and 1,460.8 keV gamma ray can be used to induce K-shell fluorescence x rays in high-Z metals between 60 and 80 keV. A gamma ray calibration source that uses potassium chloride salt and a high-Z metal to create a two-point calibration for a sodium iodide field gamma spectroscopy instrument is thus proposed. The calibration source was designed in collaboration with the Sandia National Laboratory using the Monte Carlo N-Particle eXtended (MCNPX) transport code. Two methods of x-ray production were explored. First, a thin high-Z layer (HZL) was interposed between the detector and the potassium chloride-urethane source matrix. Second, bismuth metal powder was homogeneously mixed with a urethane binding agent to form a potassium chloride-bismuth matrix (KBM). The bismuth-based source was selected as the development model because it is inexpensive, nontoxic, and outperforms the high-Z layer method in simulation. Based on the MCNPX studies, sealing a mixture of bismuth powder and potassium chloride into a thin plastic case could provide a light, inexpensive field calibration source. PMID:27115223

  15. Amorphous silicon ionizing particle detectors

    DOEpatents

    Street, Robert A.; Mendez, Victor P.; Kaplan, Selig N.

    1988-01-01

    Amorphous silicon ionizing particle detectors having a hydrogenated amorphous silicon (a--Si:H) thin film deposited via plasma assisted chemical vapor deposition techniques are utilized to detect the presence, position and counting of high energy ionizing particles, such as electrons, x-rays, alpha particles, beta particles and gamma radiation.

  16. Amorphous silicon ionizing particle detectors

    DOEpatents

    Street, R.A.; Mendez, V.P.; Kaplan, S.N.

    1988-11-15

    Amorphous silicon ionizing particle detectors having a hydrogenated amorphous silicon (a--Si:H) thin film deposited via plasma assisted chemical vapor deposition techniques are utilized to detect the presence, position and counting of high energy ionizing particles, such as electrons, x-rays, alpha particles, beta particles and gamma radiation. 15 figs.

  17. Turnip yellow mosaic virus forms infectious particles without the native beta-annulus structure and flexible coat protein N-terminus.

    PubMed

    Powell, Joshua D; Barbar, Elisar; Dreher, Theo W

    2012-01-20

    Structural studies have implicated the TYMV N-terminal amino acids of the coat protein (CP) in both static (virion stabilization) and dynamic (RNA encapsidation and disencapsidation) roles. We have deleted residues 2-5, 2-10 and 2-26 from the N-terminus and expressed the mutant CPs in E. coli to assess assembly in the absence of genomic RNA and in plant infections to assess infectivity and virion properties. In E. coli, the deletion constructs formed virus-like particles, but in decreased yield. All mutants were infectious in Chinese cabbage, producing normal symptoms but with a slight delay and decreased viral yields. Virions were progressively less stable with increasing deletion size and also more accessible to small molecules. These results show that the N-terminal 26 amino acids are not essential for viral processes in vivo, although removal of these residues decreases stability and increases porosity, both important factors for virion integrity and survival outside the host. PMID:22078163

  18. Fast ion beta limit measurements by collimated neutron detection in MST plasmas

    NASA Astrophysics Data System (ADS)

    Capecchi, William; Anderson, Jay; Bonofiglo, Phillip; Kim, Jungha; Sears, Stephanie

    2015-11-01

    Fast ion orbits in the reversed field pinch (RFP) are well ordered and classically confined despite magnetic field stochasticity generated by multiple tearing modes. Classical TRANSP modeling of a 1MW tangentially injected hydrogen neutral beam in MST deuterium plasmas predicts a core-localized fast ion density that can be up to 25% of the electron density and a fast ion beta of many times the local thermal beta. However, neutral particle analysis of an NBI-driven mode (presumably driven by a fast ion pressure gradient) shows mode-induced transport of core-localized fast ions and a saturated fast ion density. The TRANSP modeling is presumed valid until the onset of the beam-driven mode and gives an initial estimate of the volume-averaged fast ion beta of 1-2% (local core value up to 10%). A collimated neutron detector for fusion product profile measurements will be used to determine the spatial distribution of fast ions, allowing for a first measurement of the critical fast-ion pressure gradient required for mode destabilization. Testing/calibration data and initial fast-ion profiles will be presented. Characterization of both the local and global fast ion beta will be done for deuterium beam injection into deuterium plasmas for comparison to TRANSP predictions. Work supported by US DOE.

  19. Jet energy calibration at the LHC

    DOE PAGES

    Schwartzman, Ariel

    2015-11-10

    In this study, jets are one of the most prominent physics signatures of high energy proton–proton (p–p) collisions at the Large Hadron Collider (LHC). They are key physics objects for precision measurements and searches for new phenomena. This review provides an overview of the reconstruction and calibration of jets at the LHC during its first Run. ATLAS and CMS developed different approaches for the reconstruction of jets, but use similar methods for the energy calibration. ATLAS reconstructs jets utilizing input signals from their calorimeters and use charged particle tracks to refine their energy measurement and suppress the effects of multiplemore » p–p interactions (pileup). CMS, instead, combines calorimeter and tracking information to build jets from particle flow objects. Jets are calibrated using Monte Carlo (MC) simulations and a residual in situ calibration derived from collision data is applied to correct for the differences in jet response between data and Monte Carlo.« less

  20. Jet energy calibration at the LHC

    SciTech Connect

    Schwartzman, Ariel

    2015-11-10

    In this study, jets are one of the most prominent physics signatures of high energy proton–proton (p–p) collisions at the Large Hadron Collider (LHC). They are key physics objects for precision measurements and searches for new phenomena. This review provides an overview of the reconstruction and calibration of jets at the LHC during its first Run. ATLAS and CMS developed different approaches for the reconstruction of jets, but use similar methods for the energy calibration. ATLAS reconstructs jets utilizing input signals from their calorimeters and use charged particle tracks to refine their energy measurement and suppress the effects of multiple p–p interactions (pileup). CMS, instead, combines calorimeter and tracking information to build jets from particle flow objects. Jets are calibrated using Monte Carlo (MC) simulations and a residual in situ calibration derived from collision data is applied to correct for the differences in jet response between data and Monte Carlo.

  1. Improving self-calibration

    NASA Astrophysics Data System (ADS)

    Enßlin, Torsten A.; Junklewitz, Henrik; Winderling, Lars; Greiner, Maksim; Selig, Marco

    2014-10-01

    Response calibration is the process of inferring how much the measured data depend on the signal one is interested in. It is essential for any quantitative signal estimation on the basis of the data. Here, we investigate self-calibration methods for linear signal measurements and linear dependence of the response on the calibration parameters. The common practice is to augment an external calibration solution using a known reference signal with an internal calibration on the unknown measurement signal itself. Contemporary self-calibration schemes try to find a self-consistent solution for signal and calibration by exploiting redundancies in the measurements. This can be understood in terms of maximizing the joint probability of signal and calibration. However, the full uncertainty structure of this joint probability around its maximum is thereby not taken into account by these schemes. Therefore, better schemes, in sense of minimal square error, can be designed by accounting for asymmetries in the uncertainty of signal and calibration. We argue that at least a systematic correction of the common self-calibration scheme should be applied in many measurement situations in order to properly treat uncertainties of the signal on which one calibrates. Otherwise, the calibration solutions suffer from a systematic bias, which consequently distorts the signal reconstruction. Furthermore, we argue that nonparametric, signal-to-noise filtered calibration should provide more accurate reconstructions than the common bin averages and provide a new, improved self-calibration scheme. We illustrate our findings with a simplistic numerical example.

  2. Teaching Elementary Particle Physics, Part II

    ERIC Educational Resources Information Center

    Hobson, Art

    2011-01-01

    In order to explain certain features of radioactive beta decay, Wolfgang Pauli suggested in 1930 that the nucleus emitted, in addition to a beta particle, another particle of an entirely new type. The hypothesized particle, dubbed the neutrino, would not be discovered experimentally for another 25 years. It's not easy to detect neutrinos, because…

  3. New radiation protection calibration facility at CERN.

    PubMed

    Brugger, Markus; Carbonez, Pierre; Pozzi, Fabio; Silari, Marco; Vincke, Helmut

    2014-10-01

    The CERN radiation protection group has designed a new state-of-the-art calibration laboratory to replace the present facility, which is >20 y old. The new laboratory, presently under construction, will be equipped with neutron and gamma sources, as well as an X-ray generator and a beta irradiator. The present work describes the project to design the facility, including the facility placement criteria, the 'point-zero' measurements and the shielding study performed via FLUKA Monte Carlo simulations.

  4. Implicit Spacecraft Gyro Calibration

    NASA Technical Reports Server (NTRS)

    Harman, Richard; Bar-Itzhack, Itzhack Y.

    2003-01-01

    This paper presents an implicit algorithm for spacecraft onboard instrument calibration, particularly to onboard gyro calibration. This work is an extension of previous work that was done where an explicit gyro calibration algorithm was applied to the AQUA spacecraft gyros. The algorithm presented in this paper was tested using simulated data and real data that were downloaded from the Microwave Anisotropy Probe (MAP) spacecraft. The calibration tests gave very good results. A comparison between the use of the implicit calibration algorithm used here with the explicit algorithm used for AQUA spacecraft indicates that both provide an excellent estimation of the gyro calibration parameters with similar accuracies.

  5. Double beta decay: A theoretical overview

    SciTech Connect

    Rosen, S.P.

    1988-01-01

    This paper reviews the theoretical possibility of double beta decay. The titles of the main sections of this paper are: Nuclear physics setting; Particle physics requirements; Kinematical features of the decay modes; Nuclear matrix elements; the Shell model and two-neutrino decay; Quasi-particle random phase approximation; and Future considerations. 18 refs., 7 tabs. (LSP)

  6. Spectral Irradiance Calibration in the Infrared. 4; 1.2-35um Spectra of Six Standard Stars

    NASA Technical Reports Server (NTRS)

    Cohen, Martin; Witteborn, Fred C.; Walker, Russell G.; Bregman, Jesse D.; Wooden, Diane H.

    1995-01-01

    We present five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars, Beta Peg, Delta Boo, Beta And, Beta Gem, and Delta Hya, augment our already created complete absolutely calibrated spectrum for a Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

  7. Spectral Irradiance Calibration in the Infrared. Part 4; 1.2 - 35 microns Spectra of Six Standard Stars

    NASA Technical Reports Server (NTRS)

    Cohen, Martin; Witteborn, Fred C.; Walker, Russell G.; Bregman, Jesse D.; Wooden, Diane H.

    1995-01-01

    We present five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars- beta Peg, alpha Boo, beta And, beta Gem, and alpha Hya-augment our already created complete absolutely calibrated spectrum for alpha Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

  8. Spectral Irradiance Calibration in the Infrared. Part 4; 1.2-35 micrometer Spectra of Six Standard Stars

    NASA Technical Reports Server (NTRS)

    Cohen, Martin; Witteborn, Fred C.; Walker, Russell, G.; Bregman, Jesse D.; Wooden, Diane H.

    1995-01-01

    Five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns are presented. The spectra were constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars (beta Peg, alpha Boo, beta And, beta Gem, and alpha Hya) augment the author's already created complete absolutely calibrated spectrum for alpha Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

  9. Automated Camera Calibration

    NASA Technical Reports Server (NTRS)

    Chen, Siqi; Cheng, Yang; Willson, Reg

    2006-01-01

    Automated Camera Calibration (ACAL) is a computer program that automates the generation of calibration data for camera models used in machine vision systems. Machine vision camera models describe the mapping between points in three-dimensional (3D) space in front of the camera and the corresponding points in two-dimensional (2D) space in the camera s image. Calibrating a camera model requires a set of calibration data containing known 3D-to-2D point correspondences for the given camera system. Generating calibration data typically involves taking images of a calibration target where the 3D locations of the target s fiducial marks are known, and then measuring the 2D locations of the fiducial marks in the images. ACAL automates the analysis of calibration target images and greatly speeds the overall calibration process.

  10. A novel silicon array designed for intraoperative charged particle imaging.

    PubMed

    Tornai, Martin P; Patt, Bradley E; Iwanczyk, Jan S; Tull, Carolyn R; MacDonald, Lawrence R; Hoffman, Edward J

    2002-11-01

    A novel Si-PIN imaging array is under investigation for a charged particle (beta, positron, or alpha) sensitive intraoperative camera to be used for (residual) tumor identification during surgery. This class of collimator-less nuclear imaging device has a higher signal response for direct interactions than its scintillator-optical detector-based counterparts. Monte Carlo simulations with 635 keV betas were performed, yielding maximum and projected ranges of 1.64 and 0.55 mm in Si. Up to 90% of these betas were completely absorbed in the first 0.30 mm. Based on these results, 300 microm thick prototype Si detector arrays were designed in a 16 x 16 crossed-grid arrangement with 0.8 mm wide orthogonal strips on 1.0 mm pitch. A NIM- and CAMAC-based high-density data acquisition and processing system was used to collect the list mode data. The system was calibrated by comparisons of measured spectra to energy deposition simulations or by direct measurement of various >100 keV conversion electron or beta emitters. Mean electronic noise per strip was <3.6 keV FWHM at room temperature. When detecting positrons, which have an accompanying 511 keV annihilation background, the flood irradiated beta/gamma ratio was approximately 40, indicating that beta images could be made without the use of background rejection techniques. The intrinsic spatial resolution corresponds to the 1 x 1 mm2 pixel size, and measurements of beta emitting point and line sources yielded FWHM resolutions of 1.5 (lateral) and 2.5 mm (diagonal), respectively, with the larger widths due to particle range blurting effects. Deconvolution of the finite source size yielded intrinsic resolutions that corresponded to the image pixel size. Transmission images of circle and line phantoms with various hole sizes and pitch were resolved with either pure beta or positron irradiation without a background correction. This novel semiconductor imaging device facilitates high charged particle and low gamma sensitivity

  11. Analytical multicollimator camera calibration

    USGS Publications Warehouse

    Tayman, W.P.

    1978-01-01

    Calibration with the U.S. Geological survey multicollimator determines the calibrated focal length, the point of symmetry, the radial distortion referred to the point of symmetry, and the asymmetric characteristiecs of the camera lens. For this project, two cameras were calibrated, a Zeiss RMK A 15/23 and a Wild RC 8. Four test exposures were made with each camera. Results are tabulated for each exposure and averaged for each set. Copies of the standard USGS calibration reports are included. ?? 1978.

  12. Particle Sizer

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Microspheres are tiny plastic beads that represent the first commercial products manufactured in orbit. An example of how they are used is a new aerodynamic particle sizer designated APS 33B produced by TSI Incorporated. TSI purchased the microspheres from the National Bureau of Standards which certified their exact size and the company uses them in calibration of the APS 33B* instrument, latest in a line of TSI systems for generating counting and weighing minute particles of submicron size. Instruments are used for evaluating air pollution control devices, quantifying environments, meteorological research, testing filters, inhalation, toxicology and other areas where generation or analysis of small airborne particles is required. * The APS 33B is no longer being manufactured. An improved version, APS 3320, is now being manufactured. 2/28/97

  13. A Bayesian approach for calibrating probability judgments

    NASA Astrophysics Data System (ADS)

    Firmino, Paulo Renato A.; Santana, Nielson A.

    2012-10-01

    Eliciting experts' opinions has been one of the main alternatives for addressing paucity of data. In the vanguard of this area is the development of calibration models (CMs). CMs are models dedicated to overcome miscalibration, i.e. judgment biases reflecting deficient strategies of reasoning adopted by the expert when inferring about an unknown. One of the main challenges of CMs is to determine how and when to intervene against miscalibration, in order to enhance the tradeoff between costs (time spent with calibration processes) and accuracy of the resulting models. The current paper dedicates special attention to this issue by presenting a dynamic Bayesian framework for monitoring, diagnosing, and handling miscalibration patterns. The framework is based on Beta-, Uniform, or Triangular-Bernoulli models and classes of judgmental calibration theories. Issues regarding the usefulness of the proposed framework are discussed and illustrated via simulation studies.

  14. Calibration of the Cassini Cosmic Dust Analyzer

    NASA Astrophysics Data System (ADS)

    Simolka, J.; Srama, R.; Albin, T.; Bugiel, S.; Kempf, S.; Li, Y.; Moragas-Klostermeyer, G.; Postberg, F.

    2015-10-01

    The Cosmic Dust Analyzer (CDA) onboard the Cassini spacecraft detects micron and sub-micron sized particles in the Saturn environment since 2004. The impact ionization based instrument measures the positive and negatives charges of the impact plasma generated by striking particles. This signals yield the impact velocity and the particle mass. Therefor the instrument needs to be carefully calibrated. Calibration is performed utilizing the dust accelerator facility in Heidelberg which is able to accelerate micron and sub-micron sized dust particles to velocities relevant in space. Particles on circular orbits in Saturn's ring plane allow cross calibration of the dust telescope since their velocity and mass range is well known. However, since the initial calibration the scientific knowledge of the local dust environment has drastically improved (thanks to Cassini). At the same time laboratory testing facilities evolved over the years and allow a better recreation of actual conditions nowdays. Especially a larger variety of dust types particularly of mineral compositions is available nowadays.

  15. SUMS calibration test report

    NASA Technical Reports Server (NTRS)

    Robertson, G.

    1982-01-01

    Calibration was performed on the shuttle upper atmosphere mass spectrometer (SUMS). The results of the calibration and the as run test procedures are presented. The output data is described, and engineering data conversion factors, tables and curves, and calibration on instrument gauges are included. Static calibration results which include: instrument sensitive versus external pressure for N2 and O2, data from each scan of calibration, data plots from N2 and O2, and sensitivity of SUMS at inlet for N2 and O2, and ratios of 14/28 for nitrogen and 16/32 for oxygen are given.

  16. Standalone Calibration Toolset

    NASA Astrophysics Data System (ADS)

    Cooper, M.

    2013-12-01

    Radioxenon measurements require a well calibrated nuclear detector, which typically requires several weeks to perform a complex analysis of the resulting data to determine the detection efficiencies. To reduce the need to have an expert in nuclear physics, PNNL has developed a Standalone Calibration Toolset (SCT), which will aid an analyst in B-y nuclear detector calibration. SCT takes data generated from measurement of isotopically pure calibration samples: Xe-135, Xe-133, Xe-133m and Xe-131m, and generates nuclear detector configuration files. This will result in a simplified calibration and will make verification and corrections to b-g detectors routine.

  17. Cereal beta-glucans

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cereal beta-glucans occur predominantly in oats and barley, but can be found in other cereals. Beta-glucan structure is a mixture of single beta-1,3-linkages and consecutive beta-1,4-linkages, and cellotriosyl and cellotetraosyl units typically make up 90-95% of entire molecule. Lichenase can hydr...

  18. Residual gas analyzer calibration

    NASA Technical Reports Server (NTRS)

    Lilienkamp, R. H.

    1972-01-01

    A technique which employs known gas mixtures to calibrate the residual gas analyzer (RGA) is described. The mass spectra from the RGA are recorded for each gas mixture. This mass spectra data and the mixture composition data each form a matrix. From the two matrices the calibration matrix may be computed. The matrix mathematics requires the number of calibration gas mixtures be equal to or greater than the number of gases included in the calibration. This technique was evaluated using a mathematical model of an RGA to generate the mass spectra. This model included shot noise errors in the mass spectra. Errors in the gas concentrations were also included in the valuation. The effects of these errors was studied by varying their magnitudes and comparing the resulting calibrations. Several methods of evaluating an actual calibration are presented. The effects of the number of gases in then, the composition of the calibration mixture, and the number of mixtures used are discussed.

  19. Synthesis of mesoporous Beta and Sn-Beta zeolites and their catalytic performances.

    PubMed

    Jin, Junjiang; Ye, Xinxin; Li, Yongsheng; Wang, Yanqin; Li, Liang; Gu, Jinlou; Zhao, Wenru; Shi, Jianlin

    2014-06-14

    Mesoporous Beta zeolite has been successfully prepared through hydrothermal synthesis in the presence of cationic ammonium-modified chitosan as the meso-template. Through a subsequent solid-gas reaction between highly dealuminated mesoporous Beta zeolite and SnCl4 steam at an elevated temperature, mesoporous Sn-Beta has been facilely obtained. It was revealed that the addition of cationic chitosan induced the nanocrystal aggregation to particle sizes of ∼300 nm, giving rise to the intercrystalline/interparticle mesoporosity. In the Sn-implanting procedure, Sn species were demonstrated to be doped into the framework of the resulting mesoporous Beta zeolite in a tetrahedral environment without structural collapse. Due to the micro/mesoporous structures, both mesoporous Beta and Sn-Beta exhibited superior performances in α-pinene isomerization, Baeyer-Villiger oxidation of 2-adamantanone by hydrogen peroxide and the isomerization of glucose in water, respectively.

  20. Beta scattering and beta back-scattering from a thin target

    SciTech Connect

    Bafandeh, H.R.

    1992-01-01

    An experimental and theoretical technique is presented to determine the distribution of transmitted and back scattered beta particles as a function of angle of incident radiation on a target. Scatterers used consisted of metallic foils of various thicknesses and atomic number, such as Al, Zn, Fe, Ag, and Zr. Three pure beta-emitting radionuclides, [sup 32]P, [sup 204]Tl, and [sup 147]Pm characterized by end-point energies of 1.71 Mev, 0.769 Mev, and 0.225 Mev, respectively, were prepared as individual sources and used in the experimental work. A scintillation detector used in conjunction with the target scatterer and a specially designed fixture that allowed rotation about its vertical rotation axis provided the proper geometry and shielding for this experiment. Finally, the author attempted to compare experimental results with computer calculations and derived an algebraic equation to predict the intensity of beta particle back-scattered radiation as a function of energy of the source material, the scattering angle, scatterer thickness, and the material of the target scatterer. Unlike the case of heavy charged particles such as alpha particles, the effects of beta particle back scattering on dose calculations cannot be ignored. Scattering effects also have important implications with respect to the measurement of beta-emitting radionuclides and the measurements of beta radiation dose.

  1. Calibration of CUORE-0 and CUORE

    NASA Astrophysics Data System (ADS)

    Cushman, Jeremy; Cuore Collaboration

    2015-10-01

    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale cryogenic experiment designed to search for neutrinoless double beta decay (0 νββ) of 130Te. The experiment consists of 988 ultracold TeO2 bolometric crystals arranged into 19 towers, which act as both the 0 νββ sources and detectors. CUORE-0, an experiment using a single CUORE-like tower, recently completed physics data-taking and set a new limit on the 0 νββ half-life of 130Te. A good understanding of the detector energy scale through regular calibration is crucial for observation of 0 νββ and other rare processes. The CUORE-0 detector is calibrated with low-activity 232Th sources placed outside the cryostat. For CUORE, due to the large number of crystals and extensive shielding around the detector, calibration sources will need to be placed inside the cryostat. I will present analysis results from the calibration of CUORE-0 and discuss the commissioning of the CUORE calibration system.

  2. Wireless Inclinometer Calibration System

    NASA Technical Reports Server (NTRS)

    2008-01-01

    A special system was fabricated to properly calibrate the wireless inclinometer, a new device that will measure the Orbiter s hang angle. The wireless inclinometer has a unique design and method of attachment to the Orbiter that will improve the accuracy of the measurements, as well as the safety and ease of the operation. The system properly calibrates the four attached inclinometers, in both the horizontal and vertical axes, without needing to remove any of the component parts. The Wireless Inclinometer Calibration System combines (1) a calibration fixture that emulates the point of attachment to the Orbiter in both the horizontal and vertical axes and the measurement surfaces, (2) an application-specific software program that accepts calibration data such as dates, zero functions, or offsets and tables, and (3) a wireless interface module that enables the wireless inclinometer to communicate with a calibration PC.

  3. SAR calibration technology review

    NASA Technical Reports Server (NTRS)

    Walker, J. L.; Larson, R. W.

    1981-01-01

    Synthetic Aperture Radar (SAR) calibration technology including a general description of the primary calibration techniques and some of the factors which affect the performance of calibrated SAR systems are reviewed. The use of reference reflectors for measurement of the total system transfer function along with an on-board calibration signal generator for monitoring the temporal variations of the receiver to processor output is a practical approach for SAR calibration. However, preliminary error analysis and previous experimental measurements indicate that reflectivity measurement accuracies of better than 3 dB will be difficult to achieve. This is not adequate for many applications and, therefore, improved end-to-end SAR calibration techniques are required.

  4. Radiometer Calibration and Characterization

    1994-12-31

    The Radiometer Calibration and Characterization (RCC) software is a data acquisition and data archival system for performing Broadband Outdoor Radiometer Calibrations (BORCAL). RCC provides a unique method of calibrating solar radiometers using techniques that reduce measurement uncertainty and better characterize a radiometer’s response profile. The RCC software automatically monitors and controls many of the components that contribute to uncertainty in an instrument’s responsivity.

  5. The Science of Calibration

    NASA Astrophysics Data System (ADS)

    Kent, S. M.

    2016-05-01

    This paper presents a broad overview of the many issues involved in calibrating astronomical data, covering the full electromagnetic spectrum from radio waves to gamma rays, and considering both ground-based and space-based missions. These issues include the science drivers for absolute and relative calibration, the physics behind calibration and the mechanisms used to transfer it from the laboratory to an astronomical source, the need for networks of calibrated astronomical standards, and some of the challenges faced by large surveys and missions.

  6. Calibrated cylindrical Mach probe in a plasma wind tunnel

    SciTech Connect

    Zhang, X.; Dandurand, D.; Gray, T.; Brown, M. R.; Lukin, V. S.

    2011-03-15

    A simple cylindrical Mach probe is described along with an independent calibration procedure in a magnetized plasma wind tunnel. A particle orbit calculation corroborates our model. The probe operates in the weakly magnetized regime in which probe dimension and ion orbit are of the same scale. Analytical and simulation models are favorably compared with experimental calibration.

  7. Calibration and optimization of proportional counter modules using Garfield

    SciTech Connect

    Chung, Kiwhan; Brockwell, Michael I; Borozdin, Konstantin N; Green, J Andrew; Hogan, Gary E; Makela, Mark F; Mariam, Fesseha G; Morris, Christopher L

    2010-01-01

    Prototypes of radiation detector arrays used for charged-particle radiography require iniliol calibration to correlate the distribution of electron arrival time to the particle track locations. This step is crucial to obtaining the spatial resolution necessary to separate particle tracks traversing the individual proportional counters in the arrays. Our past attempts to use cosmic rays alone for the initial calibration have fallen short of obtaining the desired resolution due to the insufficient cosmic ray flux to provide the necessary number of particle tracks. A theoretical relation between electron drift time and radial drift distance is obtained with Garfield, a CERN gas detector simulation program. This relation is then used as an effective starting point for the initial calibration and results in a shorter calibration period and improved spatial resolution of the detectors.

  8. DOE Radiological Calibrations Intercomparison Program: Results of fiscal year 1987

    SciTech Connect

    Cummings, F.M.; McDonald, J.C.

    1988-06-01

    This report presents the FY 1987 results of the radiological calibrations intercomparison program. The intercomparison operation is discussed, and the equipment is described, particularly the instrument set, the beta source set, and relevant calculations. Solutions to problems and improvements in the program are suggested, and conclusions are then introduced. 9 refs., 3 figs., 8 tabs.

  9. Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging

    SciTech Connect

    Tornai, M.P.; Hoffman, E.J.; MacDonald, L.R.; Levin, C.S.

    1996-12-01

    Development of a small area (1--2 cm{sup 2}) in situ beta imaging device includes optimization of the front end scintillation detector, which is fiber optically coupled to a remote photon detector. Thin plastic scintillation detectors, which are sensitive to charged particles, are the ideal detectors due to the low sensitivity to ambient gamma backgrounds. The light output of a new binary plastic scintillator was investigated with respect to increasing concentrations of the fluor (0.5--2.0% by weight) and varying thickness cylindrical configurations of the intended imaging detector. The fluor had an emission maximum increasing from 431 to 436 nm with increasing fluor concentration. The decay time(s) had two components (0.38 and 1.74 ns). There was an {approximately}20% increase in light output with increasing fluor concentration measured with both {sup 204}Tl betas and conversion electrons from {sup 207}Bi. The highest light output of this new scintillator was measured to be {approximately}30% lower than BC404. Simulations predicted the 1.5 mm scintillator thickness at which light output and energy absorption for {approximately}700 keV electrons (e.g., from {sup 204}Tl, {sup 18}F) were maximized, which corresponded with measurements. As beta continua are relatively featureless, energy calibration for the thin scintillators was investigated using Landau distributions, which appear as distinct peaks in the spectra. As the scintillators were made thinner, gamma backgrounds were shown to linearly decrease.

  10. beta-Hexachlorocyclohexane (beta-HCH)

    Integrated Risk Information System (IRIS)

    beta - Hexachlorocyclohexane ( beta - HCH ) ; CASRN 319 - 85 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Asses

  11. Ophthalmic applicators: An overview of calibrations following the change to SI units

    SciTech Connect

    Holmes, Shannon M.; Micka, John A.; DeWerd, Larry A.

    2009-05-15

    Since the NIST dose to water standard for {sup 90}Sr/{sup 90}Y ophthalmic applicators was introduced, numerous sources have undergone calibration either at NIST or at the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL). From 1997 to 2008, 222 of these beta-emitting sources were calibrated at the UWADCL, and prior reference source strength values were available for 149 of these sources. A survey of UWADCL ophthalmic applicator calibrations is presented here, demonstrating an average discrepancy of -19% with a standard deviation of {+-}16% between prior reference values and the NIST-traceable UWADCL absorbed dose to water calibrations. Values ranged from -49% to +42%.

  12. Synthesis of plastic scintillation microspheres: alpha/beta discrimination.

    PubMed

    Santiago, L M; Bagán, H; Tarancón, A; Garcia, J F

    2014-11-01

    Plastic scintillation microspheres (PSm) have been developed as an alternative for liquid scintillation cocktails due to their ability to avoid the mixed waste, besides other strengths in which the possibility for alpha/beta discrimination is included. The aim of this work was to evaluate the capability of PSm containing two combinations of fluorescence solutes (PPO/POPOP and pT/Bis-MSB) and variable amounts of a second organic solvent (naphthalene) to enhance the alpha/beta discrimination. Two commercial detectors with different Pulse Shape Discrimination performances (Quantulus and Triathler) were used to evaluate the alpha/beta discrimination. An optimal discrimination of alpha/beta particles was reached, with very low misclassification values (2% for beta particles and 0.5% for alpha particles), when PSm containing PPO/POPOP and between 0.6 and 2.0 g of naphthalene were evaluated using Triathler and the appropriate programme for data processing.

  13. Photogrammetric camera calibration

    USGS Publications Warehouse

    Tayman, W.P.; Ziemann, H.

    1984-01-01

    Section 2 (Calibration) of the document "Recommended Procedures for Calibrating Photogrammetric Cameras and Related Optical Tests" from the International Archives of Photogrammetry, Vol. XIII, Part 4, is reviewed in the light of recent practical work, and suggestions for changes are made. These suggestions are intended as a basis for a further discussion. ?? 1984.

  14. Calibration and validation areas

    NASA Astrophysics Data System (ADS)

    Menard, Y.

    1984-08-01

    Difficulties in calibrating the SEASAT altimeter using the Bermuda laser site are recalled, and the use of Dakar (Senegal) for altimeter calibration is discussed. The site is flat, has clear skies for 200 to 250 days per year, and a local tide model is available. Atmospheric parameters can be studied using existing facilities with two additional weather stations.

  15. OLI Radiometric Calibration

    NASA Technical Reports Server (NTRS)

    Markham, Brian; Morfitt, Ron; Kvaran, Geir; Biggar, Stuart; Leisso, Nathan; Czapla-Myers, Jeff

    2011-01-01

    Goals: (1) Present an overview of the pre-launch radiance, reflectance & uniformity calibration of the Operational Land Imager (OLI) (1a) Transfer to orbit/heliostat (1b) Linearity (2) Discuss on-orbit plans for radiance, reflectance and uniformity calibration of the OLI

  16. Sandia WIPP calibration traceability

    SciTech Connect

    Schuhen, M.D.; Dean, T.A.

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities.

  17. Self-calibration performance in stereoscopic PIV acquired in a transonic wind tunnel

    NASA Astrophysics Data System (ADS)

    Beresh, Steven J.; Wagner, Justin L.; Smith, Barton L.

    2016-04-01

    Three stereoscopic PIV experiments have been examined to test the effectiveness of self-calibration under varied circumstances. Measurements taken in a streamwise plane yielded a robust self-calibration that returned common results regardless of the specific calibration procedure, but measurements in the crossplane exhibited substantial velocity bias errors whose nature was sensitive to the particulars of the self-calibration approach. Self-calibration is complicated by thick laser sheets and large stereoscopic camera angles and further exacerbated by small particle image diameters and high particle seeding density. Despite the different answers obtained by varied self-calibrations, each implementation locked onto an apparently valid solution with small residual disparity and converged adjustment of the calibration plane. Therefore, the convergence of self-calibration on a solution with small disparity is not sufficient to indicate negligible velocity error due to the stereo calibration.

  18. Gamma camera calibration and validation for quantitative SPECT imaging with (177)Lu.

    PubMed

    D'Arienzo, M; Cazzato, M; Cozzella, M L; Cox, M; D'Andrea, M; Fazio, A; Fenwick, A; Iaccarino, G; Johansson, L; Strigari, L; Ungania, S; De Felice, P

    2016-06-01

    Over the last years (177)Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, (177)Lu emits low energy gamma radiation of 113keV and 208keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives. The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with (177)Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with (177)LuCl3. Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208keV, with agreement within 5% for all geometries. The use of a Jaszczak 16mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1% for the 208keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in

  19. Gamma camera calibration and validation for quantitative SPECT imaging with (177)Lu.

    PubMed

    D'Arienzo, M; Cazzato, M; Cozzella, M L; Cox, M; D'Andrea, M; Fazio, A; Fenwick, A; Iaccarino, G; Johansson, L; Strigari, L; Ungania, S; De Felice, P

    2016-06-01

    Over the last years (177)Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, (177)Lu emits low energy gamma radiation of 113keV and 208keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives. The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with (177)Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with (177)LuCl3. Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208keV, with agreement within 5% for all geometries. The use of a Jaszczak 16mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1% for the 208keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in

  20. Calibration method for spectroscopic systems

    DOEpatents

    Sandison, David R.

    1998-01-01

    Calibration spots of optically-characterized material placed in the field of view of a spectroscopic system allow calibration of the spectroscopic system. Response from the calibration spots is measured and used to calibrate for varying spectroscopic system operating parameters. The accurate calibration achieved allows quantitative spectroscopic analysis of responses taken at different times, different excitation conditions, and of different targets.

  1. Calibration method for spectroscopic systems

    DOEpatents

    Sandison, D.R.

    1998-11-17

    Calibration spots of optically-characterized material placed in the field of view of a spectroscopic system allow calibration of the spectroscopic system. Response from the calibration spots is measured and used to calibrate for varying spectroscopic system operating parameters. The accurate calibration achieved allows quantitative spectroscopic analysis of responses taken at different times, different excitation conditions, and of different targets. 3 figs.

  2. Beta scaling of transport in microturbulence simulations

    SciTech Connect

    Candy, J.

    2005-07-15

    A systematic study of the beta ({beta}) scaling and spatial structure of thermal and particle transport in gyrokinetic turbulence simulations is presented. Here, {beta} is the ratio of the plasma kinetic pressure to the magnetic pressure. Results show that the nonlinear self-consistent temperature profiles exhibit a (statistically) time-stationary flattening in the vicinity of rational surfaces with a concomitant drop in the electrostatic components of the thermal diffusivity. Simultaneously, the increased magnetic fluctuation amplitude at these surfaces enhances the steady-state electromagnetic (flutter) component of the electron thermal diffusivity. The electromagnetic components of the ion transport coefficients remain close to zero, as expected on theoretical grounds. Only a weak dependence of ion energy transport on {beta} is observed, consistent with recent tokamak experiments [C. C. Petty et al., Phys. Plasmas 11, 2514 (2004)].

  3. Gemini facility calibration unit

    NASA Astrophysics Data System (ADS)

    Ramsay-Howat, Suzanne K.; Harris, John W.; Gostick, David C.; Laidlaw, Ken; Kidd, Norrie; Strachan, Mel; Wilson, Ken

    2000-08-01

    High-quality, efficient calibration instruments is a pre- requisite for the modern observatory. Each of the Gemini telescopes will be equipped with identical facility calibration units (GCALs) designed to provide wavelength and flat-field calibrations for the suite of instruments. The broad range of instrumentation planned for the telescopes heavily constrains the design of GCAL. Short calibration exposures are required over wavelengths from 0.3micrometers to 5micrometers , field sizes up to 7 arcminutes and spectral resolution from R-5 to 50,000. The output from GCAL must mimic the f-16 beam of the telescope and provide a uniform illumination of the focal plane. The calibration units are mounted on the Gemini Instrument Support Structure, two meters from the focal pane, necessitating the use of large optical components. We will discuss the opto-mechanical design of the Gemini calibration unit, with reference to those feature which allow these stringent requirements to be met. A novel reflector/diffuser unit replaces the integration sphere more normally found in calibration systems. The efficiency of this system is an order of magnitude greater than for an integration sphere. A system of two off-axis mirrors reproduces the telescope pupil and provides the 7 foot focal plane. The results of laboratory test of the uniformity and throughput of the GCAL will be presented.

  4. Comparison of Continuous Wave CO2 Doppler Lidar Calibration Using Earth Surface Targets in Laboratory and Airborne Measurements

    NASA Technical Reports Server (NTRS)

    Jarzembski, Maurice A.; Srivastava, Vandana

    1999-01-01

    Routine backscatter, beta, measurements by an airborne or space-based lidar from designated earth surfaces with known and fairly uniform beta properties can potentially offer lidar calibration opportunities. This can in turn be used to obtain accurate atmospheric aerosol and cloud beta measurements on large spatial scales. This is important because achieving a precise calibration factor for large pulsed lidars then need not rest solely on using a standard hard target procedure. Furthermore, calibration from designated earth surfaces would provide an inflight performance evaluation of the lidar. Hence, with active remote sensing using lasers with high resolution data, calibration of a space-based lidar using earth's surfaces will be extremely useful. The calibration methodology using the earth's surface initially requires measuring beta of various earth surfaces simulated in the laboratory using a focused continuous wave (CW) CO2 Doppler lidar and then use these beta measurements as standards for the earth surface signal from airborne or space-based lidars. Since beta from the earth's surface may be retrieved at different angles of incidence, beta would also need to be measured at various angles of incidences of the different surfaces. In general, Earth-surface reflectance measurements have been made in the infrared, but the use of lidars to characterize them and in turn use of the Earth's surface to calibrate lidars has not been made. The feasibility of this calibration methodology is demonstrated through a comparison of these laboratory measurements with actual earth surface beta retrieved from the same lidar during the NASA/Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) mission on NASA's DC8 aircraft from 13 - 26 September, 1995. For the selected earth surface from the airborne lidar data, an average beta for the surface was established and the statistics of lidar efficiency was determined. This was compared with the actual lidar efficiency

  5. Calibration of acoustic transients.

    PubMed

    Burkard, Robert

    2006-05-26

    This article reviews the appropriate stimulus parameters (click duration, toneburst envelope) that should be used when eliciting auditory brainstem responses from mice. Equipment specifications required to calibrate these acoustic transients are discussed. Several methods of calibrating the level of acoustic transients are presented, including the measurement of peak equivalent sound pressure level (peSPL) and peak sound pressure level (pSPL). It is hoped that those who collect auditory brainstem response thresholds in mice will begin to use standardized methods of acoustic calibration, so that hearing thresholds across mouse strains obtained in different laboratories can more readily be compared.

  6. Dynamic Pressure Calibration Standard

    NASA Technical Reports Server (NTRS)

    Schutte, P. C.; Cate, K. H.; Young, S. D.

    1986-01-01

    Vibrating columns of fluid used to calibrate transducers. Dynamic pressure calibration standard developed for calibrating flush diaphragm-mounted pressure transducers. Pressures up to 20 kPa (3 psi) accurately generated over frequency range of 50 to 1,800 Hz. System includes two conically shaped aluminum columns one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with viscous fluid. Each column mounted on armature of vibration exciter, which imparts sinusoidally varying acceleration to fluid column. Signal noise low, and waveform highly dependent on quality of drive signal in vibration exciter.

  7. Lidar Calibration Centre

    NASA Astrophysics Data System (ADS)

    Pappalardo, Gelsomina; Freudenthaler, Volker; Nicolae, Doina; Mona, Lucia; Belegante, Livio; D'Amico, Giuseppe

    2016-06-01

    This paper presents the newly established Lidar Calibration Centre, a distributed infrastructure in Europe, whose goal is to offer services for complete characterization and calibration of lidars and ceilometers. Mobile reference lidars, laboratories for testing and characterization of optics and electronics, facilities for inspection and debugging of instruments, as well as for training in good practices are open to users from the scientific community, operational services and private sector. The Lidar Calibration Centre offers support for trans-national access through the EC HORIZON2020 project ACTRIS-2.

  8. Airdata Measurement and Calibration

    NASA Technical Reports Server (NTRS)

    Haering, Edward A., Jr.

    1995-01-01

    This memorandum provides a brief introduction to airdata measurement and calibration. Readers will learn about typical test objectives, quantities to measure, and flight maneuvers and operations for calibration. The memorandum informs readers about tower-flyby, trailing cone, pacer, radar-tracking, and dynamic airdata calibration maneuvers. Readers will also begin to understand how some data analysis considerations and special airdata cases, including high-angle-of-attack flight, high-speed flight, and nonobtrusive sensors are handled. This memorandum is not intended to be all inclusive; this paper contains extensive reference and bibliography sections.

  9. Compact radiometric microwave calibrator

    SciTech Connect

    Fixsen, D. J.; Wollack, E. J.; Kogut, A.; Limon, M.; Mirel, P.; Singal, J.; Fixsen, S. M.

    2006-06-15

    The calibration methods for the ARCADE II instrument are described and the accuracy estimated. The Steelcast coated aluminum cones which comprise the calibrator have a low reflection while maintaining 94% of the absorber volume within 5 mK of the base temperature (modeled). The calibrator demonstrates an absorber with the active part less than one wavelength thick and only marginally larger than the mouth of the largest horn and yet black (less than -40 dB or 0.01% reflection) over five octaves in frequency.

  10. DIRBE External Calibrator (DEC)

    NASA Technical Reports Server (NTRS)

    Wyatt, Clair L.; Thurgood, V. Alan; Allred, Glenn D.

    1987-01-01

    Under NASA Contract No. NAS5-28185, the Center for Space Engineering at Utah State University has produced a calibration instrument for the Diffuse Infrared Background Experiment (DIRBE). DIRBE is one of the instruments aboard the Cosmic Background Experiment Observatory (COBE). The calibration instrument is referred to as the DEC (Dirbe External Calibrator). DEC produces a steerable, infrared beam of controlled spectral content and intensity and with selectable point source or diffuse source characteristics, that can be directed into the DIRBE to map fields and determine response characteristics. This report discusses the design of the DEC instrument, its operation and characteristics, and provides an analysis of the systems capabilities and performance.

  11. Calibration Fixture For Anemometer Probes

    NASA Technical Reports Server (NTRS)

    Lewis, Charles R.; Nagel, Robert T.

    1993-01-01

    Fixture facilitates calibration of three-dimensional sideflow thermal anemometer probes. With fixture, probe oriented at number of angles throughout its design range. Readings calibrated as function of orientation in airflow. Calibration repeatable and verifiable.

  12. Multigamma-ray calibration sources

    SciTech Connect

    Meyer, R.A.; Massey, T.N.

    1983-05-01

    We have calibrated a self-consistent set of multigamma-ray standards using the automated multi-spectrometry ..gamma..-ray counting facility at LLNL's Nuclear Chemistry Division. Pure sources of long-lived activity were produced by mass separation and/or chemical purification. The sources were counted individually and in combination on several different calibrated spectrometer systems. These systems utilize various detectors ranging from small (x-ray) detectors to large volume high-purity Ge detectors. This has allowed the use of the most ideal individual detector-efficiency characteristics for the determination of the relative ..gamma..-ray intensities. Precise energy measurements, reported earlier (Meyer, 1976) have been performed by an independent method. Both the energy and ..gamma..-ray-emission probabilities determined compare well with independently established values such as the recent ICRM intercomparison of /sup 152/Eu. We discuss our investigations aimed at resolving the shape of the efficiency response function up to 10 MeV for large volume Ge(Li) and high-purity Ge detectors. Recent results on the ..gamma..-ray-emission probabilities per decay for /sup 149/Gd and /sup 168/Tm multigamma-ray sources are discussed. For /sup 168/Tm, we deduce a 0.01% ..beta../sup -/ branch to the 87.73-keV level in /sup 168/Yb rather than the previous value which was a factor of 200 greater. In addition, we describe current cooperative efforts aimed at establishing a consistent set of data for short-lived fission products. Included are recent measurements on the bromine fission products with ..gamma.. rays up to 7 MeV.

  13. In situ ``artificial plasma'' calibration of tokamak magnetic sensors

    NASA Astrophysics Data System (ADS)

    Shiraki, D.; Levesque, J. P.; Bialek, J.; Byrne, P. J.; DeBono, B. A.; Mauel, M. E.; Maurer, D. A.; Navratil, G. A.; Pedersen, T. S.; Rath, N.

    2013-06-01

    A unique in situ calibration technique has been used to spatially calibrate and characterize the extensive new magnetic diagnostic set and close-fitting conducting wall of the High Beta Tokamak-Extended Pulse (HBT-EP) experiment. A new set of 216 Mirnov coils has recently been installed inside the vacuum chamber of the device for high-resolution measurements of magnetohydrodynamic phenomena including the effects of eddy currents in the nearby conducting wall. The spatial positions of these sensors are calibrated by energizing several large in situ calibration coils in turn, and using measurements of the magnetic fields produced by the various coils to solve for each sensor's position. Since the calibration coils are built near the nominal location of the plasma current centroid, the technique is referred to as an "artificial plasma" calibration. The fitting procedure for the sensor positions is described, and results of the spatial calibration are compared with those based on metrology. The time response of the sensors is compared with the evolution of the artificial plasma current to deduce the eddy current contribution to each signal. This is compared with simulations using the VALEN electromagnetic code, and the modeled copper thickness profiles of the HBT-EP conducting wall are adjusted to better match experimental measurements of the eddy current decay. Finally, the multiple coils of the artificial plasma system are also used to directly calibrate a non-uniformly wound Fourier Rogowski coil on HBT-EP.

  14. In situ calibration of inductively coupled plasma-atomic emission and mass spectroscopy

    DOEpatents

    Braymen, Steven D.

    1996-06-11

    A method and apparatus for in situ addition calibration of an inductively coupled plasma atomic emission spectrometer or mass spectrometer using a precision gas metering valve to introduce a volatile calibration gas of an element of interest directly into an aerosol particle stream. The present situ calibration technique is suitable for various remote, on-site sampling systems such as laser ablation or nebulization.

  15. Roundness calibration standard

    DOEpatents

    Burrus, Brice M.

    1984-01-01

    A roundness calibration standard is provided with a first arc constituting the major portion of a circle and a second arc lying between the remainder of the circle and the chord extending between the ends of said first arc.

  16. Calibrated Properties Model

    SciTech Connect

    C.F. Ahlers, H.H. Liu

    2001-12-18

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the AMR Development Plan for U0035 Calibrated Properties Model REV00 (CRWMS M&O 1999c). These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions.

  17. Calibrated Properties Model

    SciTech Connect

    C. Ahlers; H. Liu

    2000-03-12

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the ''AMR Development Plan for U0035 Calibrated Properties Model REV00. These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions.

  18. Radar altimeter calibration

    NASA Astrophysics Data System (ADS)

    Francis, C. R.

    1983-02-01

    The operating principles and design of a radar altimeter representative of those proposed of ERS-1 are described and geophysical influences on the measurements are discussed. General aspects of calibration are examined, and the critical areas of time and frequency resolution pointed out. A method of internal calibration of delay and backscatter coefficient, by rerouting the tramsitter signal, is described. External prelaunch calibration can be carried out by airborne trials, or using a return signal simulator. It is established that airborne calibration requires high altitudes and high speeds, and is likely to be difficult and expensive. The design of a return signal simulator is shown to be very difficult. No feasible design is identified.

  19. In-place HEPA (high efficiency, particulate air) filter testing at Hanford: Operating experiences, calibrations, and lessons learned

    SciTech Connect

    Flores, D.S.; Decelis, D.G.

    1989-10-01

    High Efficiency, Particulate Air (HEPA) Filters provide a minimum of 99.97% removal efficiency for particles greater than or equal to .3 microns in diameter. Each HEPA filter installation at Hanford is, at specified intervals, functionally tested for leaks. The test procedure involves a dioctylphthalate (DOP) smoke generator and a calibrated airborne particle detector. The DOP generator produces smoke of a known quantitative particle size distribution upstream of the filter. The airborne particle detector is first placed upstream, and then downstream of the filter to determine percent penetration. The smoke generator is characterized using a calibrated laser spectrometer, and the particle detector is calibrated using a calibrated picoammeter. 2 refs., 4 figs.

  20. DOE radiological calibrations intercomparison program: Results of fiscal year 1986

    SciTech Connect

    Cummings, F.M.; Roberson, P.L.; McDonald, J.C.

    1987-05-01

    The Department of Energy Radiological Calibration Intercomparison Program was initiated in January 1986, under the research portion of the DOE Laboratory Accreditation Program. The program operates via the exchange of transfer standards, consisting of instrument sets and standard secondary beta sources. There are two instrument sets and the scheduled use has been staggered such that one set is available for use during each month. One set of secondary standard beta sources is available for use bimonthly. During the 1986 fiscal year, five laboratories used the instrument sets and three laboratories used the beta source set. Results were reported for all the measurements. The average and one standard deviation of the ratios of participant results to Pacific Northwest Laboratory calibration values were 1.12 +- 0.17 for gamma measurements. Those ratios for the gamma measurements varied from 0.98 to 3.06. The larger differences of results from measurements performed at two facilities were directly attributable to unfamiliarity with the intercomparison instruments. The average and one standard deviation of the ratios of participant results to PNL calibration values obtained using the secondary /sup 90/Sr beta source was 1.02 +- 0.05, which is well within measurement uncertainties. The one participant who performed measurements using /sup 147/Pm and /sup 204/Tl sources obtained ratios of 0.68 and 1.11, respectively. No measurements were performed using neutron or x-ray sources.

  1. Teaching Elementary Particle Physics, Part II

    NASA Astrophysics Data System (ADS)

    Hobson, Art

    2011-03-01

    In order to explain certain features of radioactive beta decay, Wolfgang Pauli suggested in 1930 that the nucleus emitted, in addition to a beta particle, another particle of an entirely new type. The hypothesized particle, dubbed the neutrino, would not be discovered experimentally for another 25 years. It's not easy to detect neutrinos, because they respond to neither the EM force nor the strong force. For example, the mean free path (average penetration distance before it interacts) of a typical beta-decay neutrino moving through solid lead is about 1.5 light years! Enrico Fermi argued that neutrinos indicated a new force was at work. During the 1930s, he quickly adapted ideas from the developing new theory of QED to this new force, dubbed the weak force. Fermi's theory was able to predict the half-lives of beta-emitting nuclei and the range of energies of the emitted beta particles.

  2. Integrated calibration sphere and calibration step fixture for improved coordinate measurement machine calibration

    DOEpatents

    Clifford, Harry J.

    2011-03-22

    A method and apparatus for mounting a calibration sphere to a calibration fixture for Coordinate Measurement Machine (CMM) calibration and qualification is described, decreasing the time required for such qualification, thus allowing the CMM to be used more productively. A number of embodiments are disclosed that allow for new and retrofit manufacture to perform as integrated calibration sphere and calibration fixture devices. This invention renders unnecessary the removal of a calibration sphere prior to CMM measurement of calibration features on calibration fixtures, thereby greatly reducing the time spent qualifying a CMM.

  3. Measurement of Yields and Fluctuations using Background and Calibration Data from the LUX Detector

    NASA Astrophysics Data System (ADS)

    Pease, Evan; LUX Collaboration

    2016-03-01

    The Large Underground Xenon (LUX) detector is a 350-kg liquid xenon (LXe) time-projection chamber designed for the direct detection of weakly-interacting massive particles (WIMPs), a leading dark matter candidate. LUX operates on the 4850-foot level of the Sanford Underground Research Facility in Lead, SD. Monoenergetic electronic recoil (ER) peaks in the WIMP search and calibration data from the first underground science run of the LUX detector have been used to measure ER light and charge yields in LXe between 5.2 keV and 662 keV. The energy resolution of the LUX detector at these energies will also be presented. Recombination fluctuations are observed to follow a linear dependence on the number of ions for the energies in this study, and this dependence is consistent with low-energy measurements made with a tritium beta source in the LUX detector. Using these results and additional measurements of the recoil bands from tritium and D-D neutron calibrations, I will compare recombination fluctuations in LXe response to electronic and nuclear recoils. The presenter is supported by the U.S. Department of Energy, Office of Science Graduate Student Research (SCGSR) program. The SCGSR program is administered by the Oak Ridge Institute for Science and Education for the DOE under contract DE-AC05-06OR23100.

  4. What can we learn from neutrinoless double beta decay experiments?

    SciTech Connect

    Bahcall, John N.; Murayama, Hitoshi; Pena-Garay, Carlos

    2004-04-08

    We assess how well next generation neutrinoless double beta decay and normal neutrino beta decay experiments can answer four fundamental questions. 1) If neutrinoless double beta decay searches do not detect a signal, and if the spectrum is known to be inverted hierarchy, can we conclude that neutrinos are Dirac particles? 2) If neutrinoless double beta decay searches are negative and a next generation ordinary beta decay experiment detects the neutrino mass scale, can we conclude that neutrinos are Dirac particles? 3) If neutrinoless double beta decay is observed with a large neutrino mass element, what is the total mass in neutrinos? 4) If neutrinoless double beta decay is observed but next generation beta decay searches for a neutrino mass only set a mass upper limit, can we establish whether the mass hierarchy is normal or inverted? We base our answers on the expected performance of next generation neutrinoless double beta decay experiments and on simulations of the accuracy of calculations of nuclear matrix elements.

  5. Neoclassical transport in high {beta} tokamaks

    SciTech Connect

    Cowley, S.C.

    1992-12-01

    Neoclassical, transport in high {beta} large aspect ratio tokamaks is calculated. The variational method introduced by Rosenbluth, et al., is used to calculate the full Onsager matrix in the banana regime. These results are part of a continuing study of the high {beta} large aspect ratio equilibria introduced in Cowley, et al. All the neoclassical coefficients are reduced from their nominal low {beta} values by a factor ({var_epsilon}/q{sup 2}{beta}){sup {1/2}} II. This factor is the ratio of plasma volume in the boundary layer to the volume in the core. The fraction of trapped particles on a given flux surface (f{sub t}) is also reduced by this factor so that {approximately} {sub ({var_epsilon}}/q{sup 2}{beta}){sup {1/2}}. Special attention is given to the current equation, since this is thought to be relevant at low 3 and therefore may also be relevant at high {beta}. The bootstrap current term is found to exceed the actual current by a factor of the square root of the aspect ratio.

  6. PERSONALISED BODY COUNTER CALIBRATION USING ANTHROPOMETRIC PARAMETERS.

    PubMed

    Pölz, S; Breustedt, B

    2016-09-01

    Current calibration methods for body counting offer personalisation for lung counting predominantly with respect to ratios of body mass and height. Chest wall thickness is used as an intermediate parameter. This work revises and extends these methods using a series of computational phantoms derived from medical imaging data in combination with radiation transport simulation and statistical analysis. As an example, the method is applied to the calibration of the In Vivo Measurement Laboratory (IVM) at Karlsruhe Institute of Technology (KIT) comprising four high-purity germanium detectors in two partial body measurement set-ups. The Monte Carlo N-Particle (MCNP) transport code and the Extended Cardiac-Torso (XCAT) phantom series have been used. Analysis of the computed sample data consisting of 18 anthropometric parameters and calibration factors generated from 26 photon sources for each of the 30 phantoms reveals the significance of those parameters required for producing an accurate estimate of the calibration function. Body circumferences related to the source location perform best in the example, while parameters related to body mass show comparable but lower performances, and those related to body height and other lengths exhibit low performances. In conclusion, it is possible to give more accurate estimates of calibration factors using this proposed approach including estimates of uncertainties related to interindividual anatomical variation of the target population. PMID:26396263

  7. Psychophysical contrast calibration

    PubMed Central

    To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli

    2013-01-01

    Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843

  8. Polarimetric Palsar Calibration

    NASA Astrophysics Data System (ADS)

    Touzi, R.; Shimada, M.

    2008-11-01

    Polarimetric PALSAR system parameters are assessed using data sets collected over various calibration sites. The data collected over the Amazonian forest permits validating the zero Faraday rotation hypotheses near the equator. The analysis of the Amazonian forest data and the response of the corner reflectors deployed during the PALSAR acquisitions lead to the conclusion that the antenna is highly isolated (better than -35 dB). Theses results are confirmed using data collected over the Sweden and Ottawa calibration sites. The 5-m height trihedrals deployed in the Sweden calibration site by the Chalmers University of technology permits accurate measurement of antenna parameters, and detection of 2-3 degree Faraday rotation during day acquisition, whereas no Faraday rotation was noted during night acquisition. Small Faraday rotation angles (2-3 degree) have been measured using acquisitions over the DLR Oberpfaffenhofen and the Ottawa calibration sites. The presence of small but still significant Faraday rotation (2-3 degree) induces a CR return at the cross-polarization HV and VH that should not be interpreted as the actual antenna cross-talk. PALSAR antenna is highly isolated (better than -35 dB), and diagonal antenna distortion matrices (with zero cross-talk terms) can be used for accurate calibration of PALSAR polarimetric data.

  9. Calibration Under Uncertainty.

    SciTech Connect

    Swiler, Laura Painton; Trucano, Timothy Guy

    2005-03-01

    This report is a white paper summarizing the literature and different approaches to the problem of calibrating computer model parameters in the face of model uncertainty. Model calibration is often formulated as finding the parameters that minimize the squared difference between the model-computed data (the predicted data) and the actual experimental data. This approach does not allow for explicit treatment of uncertainty or error in the model itself: the model is considered the %22true%22 deterministic representation of reality. While this approach does have utility, it is far from an accurate mathematical treatment of the true model calibration problem in which both the computed data and experimental data have error bars. This year, we examined methods to perform calibration accounting for the error in both the computer model and the data, as well as improving our understanding of its meaning for model predictability. We call this approach Calibration under Uncertainty (CUU). This talk presents our current thinking on CUU. We outline some current approaches in the literature, and discuss the Bayesian approach to CUU in detail.

  10. POLCAL - POLARIMETRIC RADAR CALIBRATION

    NASA Technical Reports Server (NTRS)

    Vanzyl, J.

    1994-01-01

    Calibration of polarimetric radar systems is a field of research in which great progress has been made over the last few years. POLCAL (Polarimetric Radar Calibration) is a software tool intended to assist in the calibration of Synthetic Aperture Radar (SAR) systems. In particular, POLCAL calibrates Stokes matrix format data produced as the standard product by the NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). POLCAL was designed to be used in conjunction with data collected by the NASA/JPL AIRSAR system. AIRSAR is a multifrequency (6 cm, 24 cm, and 68 cm wavelength), fully polarimetric SAR system which produces 12 x 12 km imagery at 10 m resolution. AIRSTAR was designed as a testbed for NASA's Spaceborne Imaging Radar program. While the images produced after 1991 are thought to be calibrated (phase calibrated, cross-talk removed, channel imbalance removed, and absolutely calibrated), POLCAL can and should still be used to check the accuracy of the calibration and to correct it if necessary. Version 4.0 of POLCAL is an upgrade of POLCAL version 2.0 released to AIRSAR investigators in June, 1990. New options in version 4.0 include automatic absolute calibration of 89/90 data, distributed target analysis, calibration of nearby scenes with calibration parameters from a scene with corner reflectors, altitude or roll angle corrections, and calibration of errors introduced by known topography. Many sources of error can lead to false conclusions about the nature of scatterers on the surface. Errors in the phase relationship between polarization channels result in incorrect synthesis of polarization states. Cross-talk, caused by imperfections in the radar antenna itself, can also lead to error. POLCAL reduces cross-talk and corrects phase calibration without the use of ground calibration equipment. Removing the antenna patterns during SAR processing also forms a very important part of the calibration of SAR data. Errors in the

  11. A miniature remote deadweight calibrator

    NASA Astrophysics Data System (ADS)

    Supplee, Frank H., Jr.; Tcheng, Ping

    A miniature, computer-controlled, deadweight calibrator was developed to remotely calibrate a force transducer mounted in a cryogenic chamber. This simple mechanism allows automatic loading and unloading of deadweights placed onto a skin friction balance during calibrations. Equipment for the calibrator includes a specially designed set of five interlocking 200-milligram weights, a motorized lifting platform, and a controller box taking commands from a microcomputer on an IEEE interface. The computer is also used to record and reduce the calibration data and control other calibration parameters. The full-scale load for this device is 1,000 milligrams; however, the concept can be extended to accommodate other calibration ranges.

  12. Calibration Systems Final Report

    SciTech Connect

    Myers, Tanya L.; Broocks, Bryan T.; Phillips, Mark C.

    2006-02-01

    The Calibration Systems project at Pacific Northwest National Laboratory (PNNL) is aimed towards developing and demonstrating compact Quantum Cascade (QC) laser-based calibration systems for infrared imaging systems. These on-board systems will improve the calibration technology for passive sensors, which enable stand-off detection for the proliferation or use of weapons of mass destruction, by replacing on-board blackbodies with QC laser-based systems. This alternative technology can minimize the impact on instrument size and weight while improving the quality of instruments for a variety of missions. The potential of replacing flight blackbodies is made feasible by the high output, stability, and repeatability of the QC laser spectral radiance.

  13. High Beta Tokamaks

    SciTech Connect

    Cowley, S.

    1998-11-14

    Perhaps the ideal tokamak would have high {beta} ({beta} {approx}> 1) and classical confinement. Such a tokamak has not been found, and we do not know if one does exist. We have searched for such a possibility, so far without success. In 1990, we obtained analytic equilibrium solutions for large aspect ratio tokamaks at {beta} {approx} {Omicron}(1) [1]. These solutions and the extension at high {beta} poloidal to finite aspect ratio [2] provided a basis for the study of high {beta} tokamaks. We have shown that these configurations can be stable to short scale MHD modes [3], and that they have reduced neoclassical transport [4]. Microinstabilities (such as the {del}T{sub i} mode) seem to be stabilized at high {beta} [5] - this is due to the large local shear [3] and the magnetic well. We have some concerns about modes associated with the compressional branch which may appear at high {beta}. Bill Dorland and Mike Kotschenreuther have studied this issue and our concerns may be unfounded. It is certainly tantalizing, especially given the lowered neoclassical transport values, that these configurations could have no microinstabilities and, one could assume, no anomalous transport. Unfortunately, while this work is encouraging, the key question for high {beta} tokamaks is the stability to large scale kink modes. The MHD {beta} limit (Troyon limit) for kink modes at large aspect ratio is problematically low. There is ample evidence from computations that the limit exists. However, it is not known if stable equilibria exist at much higher {beta}--none have been found. We have explored this question in the asymptotic high {beta} poloidal limit. Unfortunately, we are unable to find stable equilibrium and also unable to show that they don't exist. The results of these calculations will be published when a more definitive answer is found.

  14. [Internal and external sources of the radiation induce the blocking of the proliferation of the human endothelial cells in culture. G2-block is induced by beta-particle 3H-thymidine and gamma-rays 137Cs].

    PubMed

    Gil'iano, N Ia; Konevega, L V; Stepanov, S I; Semenova, E G; Noskin, L A

    2007-01-01

    We found that low doses (0.12-0.46Gy) of (methyl-) 3H-thymidine incorporated into human endothelial cells induce the accumulation cells in G2-phase of the cell cycle. Temperate doses of (1-6 Gy) gamma-rays 137Cs were less effective in the G2-block estimated by flow cytometry analysis of DNA content. Furthermore, the induced the high level of the chromosome aberrations (bridges and fragments in anaphases). 1Gy of gamma-ray 137Cs and 0.005 Gy of beta-rays induced the same per cent of the aberrant anaphases. Apparently, that the damages of the cellular hereditary structures are responsible for the blocking of the cellular proliferation in G2-phase. We suggest, that the disposition 3H-thymidine into radiosensitive target (DNA) defines the high cytotoxic of the beta-rays.

  15. beta-Cyclodextrin-bonded silica particles as the solid-phase extraction medium for the determination of phenol compounds in water samples followed by gas chromatography with flame ionization and mass spectrometry detection.

    PubMed

    Faraji, Hakim

    2005-09-16

    A new absorbent for solid-phase extraction (SPE) was prepared by a beta-cyclodextrin bonded silica stationary phase (CDS) has been applied to determine the concentrations of phenol compounds in water samples. SPE of selected phenolic compounds from aqueous samples were performed using 250 mg CDS. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). Compared with available SPE, the CDS showed high sensitivity and fast velocity of mass transfer for phenolic compound because of its porous structure of beta-cyclodextrin. The relative standard deviation (RSD) for river water sample spiked with phenolic compounds at sub-ppb level was lower than 10% and limit of detection (LOD) for these compounds were between 10 and 100 ng l(-1). PMID:16130725

  16. DOE radiological calibrations intercomparison program: Results of fiscal year 1988

    SciTech Connect

    Cummings, F.M.; McDonald, J.C.; Murphy, M.K.

    1989-08-01

    Calibration measurements for personnel dosimetry purposes must be both accurate and consistent with national standards. In order to satisfy these requirements, the following methods are usually employed. In one case, a radiation source is sent to the National Institute of Standards and Technology (NIST), formerly the National Bureau of Standards, for calibration and is returned to the laboratory to be used as a local standard. Another method involves the calibration of an instrument, such as an ionization chamber, by NIST. After calibration, this instrument is then used to measure the exposure rate delivered by radiation sources at the laboratory. Such calibrations by NIST are essential, but they do not provide a complete check on the quality of the calibrations that are carried out by the individual laboratory. Additional measurements are necessary to assure the quality of such measurements. When laboratory staff are asked to carry our measurements with calibrated instruments and report results for evaluation, they are participating in a measurement quality assurance (MQA) program. Such a program tests not only the quality of the equipment but also the ability of the staff to correctly use and interpret the results obtained with the equipment. The NIST operates an MQA program with a selected number of calibration laboratories. Pacific Northwest Laboratory (PNL) participates in this MQA program even though NIST test only x-ray and gamma-ray measurements. The US Department of Energy (DOE) intercomparison program was designed specifically to include x-ray, gamma-ray, beta, and neutron calibrations for personnel dosimetry purposes. This program serves a need that is not being met by NIST, and it provides documentation of the accuracy and uniformity of the radiological calibrations carried out in DOE facilities. 7 refs., 3 figs., 6 tabs.

  17. Iterative Magnetometer Calibration

    NASA Technical Reports Server (NTRS)

    Sedlak, Joseph

    2006-01-01

    This paper presents an iterative method for three-axis magnetometer (TAM) calibration that makes use of three existing utilities recently incorporated into the attitude ground support system used at NASA's Goddard Space Flight Center. The method combines attitude-independent and attitude-dependent calibration algorithms with a new spinning spacecraft Kalman filter to solve for biases, scale factors, nonorthogonal corrections to the alignment, and the orthogonal sensor alignment. The method is particularly well-suited to spin-stabilized spacecraft, but may also be useful for three-axis stabilized missions given sufficient data to provide observability.

  18. Development of a three-layer phoswich alpha-beta-gamma imaging detector

    NASA Astrophysics Data System (ADS)

    Yamamoto, Seiichi; Ishibashi, Hiroyuki

    2015-06-01

    For radiation monitoring at the sites of such nuclear power plant accidents as Fukushima Daiichi, radiation detectors are needed not only for gamma photons but also for alpha and beta particles because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. In some applications, imaging detectors are required to detect the distribution of plutonium particles that emit alpha particles and radiocesium in foods that emits beta particles and gamma photons. To solve these requirements, we developed an imaging detector that can measure the distribution of alpha and beta particles as well as gamma photons. The imaging detector consists of three-layer scintillators optically coupled to each other and to a position sensitive photomultiplier tube (PSPMT). The first layer, which is made of a thin plastic scintillator (decay time: ~5 ns), detects alpha particles. The second layer, which is made of a thin Gd2SiO5 (GSO) scintillator with 1.5 mol% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol% Ce (decay time: 70 ns) detects gamma photons. Using pulse shape discrimination, the images of these layers can be separated. The position information is calculated by the Anger principle from 8×8 anode signals from the PSPMT. The images for the alpha and beta particles and the gamma photons are individually formed by the pulse shape discriminations for each layer. We detected alpha particle images in the first layer and beta particle images in the second layer. Gamma photon images were detected in the second and third layers. The spatial resolution for the alpha and beta particles was ~1.25 mm FWHM and less than 2 mm FWHM for the gamma photons. We conclude that our developed alpha-beta-gamma imaging detector is promising for imaging applications not only for the environmental monitoring of radionuclides but also for medical and molecular imaging.

  19. Improved Regression Calibration

    ERIC Educational Resources Information Center

    Skrondal, Anders; Kuha, Jouni

    2012-01-01

    The likelihood for generalized linear models with covariate measurement error cannot in general be expressed in closed form, which makes maximum likelihood estimation taxing. A popular alternative is regression calibration which is computationally efficient at the cost of inconsistent estimation. We propose an improved regression calibration…

  20. Thermistor mount efficiency calibration

    SciTech Connect

    Cable, J.W.

    1980-05-01

    Thermistor mount efficiency calibration is accomplished by use of the power equation concept and by complex signal-ratio measurements. A comparison of thermistor mounts at microwave frequencies is made by mixing the reference and the reflected signals to produce a frequency at which the amplitude and phase difference may be readily measured.

  1. Pseudo Linear Gyro Calibration

    NASA Technical Reports Server (NTRS)

    Harman, Richard; Bar-Itzhack, Itzhack Y.

    2003-01-01

    Previous high fidelity onboard attitude algorithms estimated only the spacecraft attitude and gyro bias. The desire to promote spacecraft and ground autonomy and improvements in onboard computing power has spurred development of more sophisticated calibration algorithms. Namely, there is a desire to provide for sensor calibration through calibration parameter estimation onboard the spacecraft as well as autonomous estimation on the ground. Gyro calibration is a particularly challenging area of research. There are a variety of gyro devices available for any prospective mission ranging from inexpensive low fidelity gyros with potentially unstable scale factors to much more expensive extremely stable high fidelity units. Much research has been devoted to designing dedicated estimators such as particular Extended Kalman Filter (EKF) algorithms or Square Root Information Filters. This paper builds upon previous attitude, rate, and specialized gyro parameter estimation work performed with Pseudo Linear Kalman Filter (PSELIKA). The PSELIKA advantage is the use of the standard linear Kalman Filter algorithm. A PSELIKA algorithm for an orthogonal gyro set which includes estimates of attitude, rate, gyro misalignments, gyro scale factors, and gyro bias is developed and tested using simulated and flight data. The measurements PSELIKA uses include gyro and quaternion tracker data.

  2. Satellite altimeter calibration techniques

    NASA Technical Reports Server (NTRS)

    Kolenkiewicz, R.; Martin, C. F.

    1990-01-01

    This paper examines calibration techniques which can most effectively satisfy the requirements of future satellites carrying high-accuracy radar altimeters, such as the ESA ERS-1 and the NASA/CNES Topex/Poseidon satellites scheduled for launch during the next five years. The calibration accuracies and the advantages and disadvantages of the four currently proposed calibration techniques for over-water calibration are discussed: (1) a tide gauge on a tower at-sea and a nearby laser, (2) a laser and a tide gauge on an island with an offshore satellite pass and a geoid tie between the satellite ground track and the laser, (3) a tide gauge on a tower at-sea with satellite positioning from multiple lasers and a GPS, and (4) a laser and a tide gauge on a tower at-sea. Error budgets for these techniques, developed on the basis of state-of-the-art tracking systems, were found to have one sigma height uncertainties in the 2.8 to 4.9 cm range.

  3. The JWST Calibration Pipeline

    NASA Astrophysics Data System (ADS)

    Chen, Christine; Muzerolle, James; Dixon, William Van Dyke; Izela Diaz, Rosa; Bushouse, Howard A.

    2015-01-01

    The James Webb Space Telescope will launch in 2018 and carry four science instruments that will observe the sky at 0.7 - 29 micron: the Near Infrared Camera (NIRCam), the Near Infrared Imager and Slitless Spectrograph (NIRISS), the Near Infrared Spectrograph (NIRSpec), and the Mid Infrared Instrument (MIRI). The Space Telescope Science Institute (STScI) is currently building a data reduction pipeline that will provide not only basic calibrated data but also higher level science products. All of the JWST detectors will be operated in non-destructive readout mode. Therefore, the first step in the pipeline will be to calculate the slopes of indivudal non-destructive readout ramps or integrations. The next step will be to generate calibrated slope images that are represent the basic calibrated data. The final step will be to combine data taken across multiple integrations and exposure. For the direct imaging and integral field spectroscopy modes, the pipeline will produce calibrated mosaicks. For the coronagraphic modes, the pipeline will produce contrast curves and PSF subtracted images.

  4. Satellite altimeter calibration techniques

    NASA Astrophysics Data System (ADS)

    Kolenkiewicz, R.; Martin, C. F.

    This paper examines calibration techniques which can most effectively satisfy the requirements of future satellites carrying high-accuracy radar altimeters, such as the ESA ERS-1 and the NASA/CNES Topex/Poseidon satellites scheduled for launch during the next five years. The calibration accuracies and the advantages and disadvantages of the four currently proposed calibration techniques for over-water calibration are discussed: (1) a tide gauge on a tower at-sea and a nearby laser, (2) a laser and a tide gauge on an island with an offshore satellite pass and a geoid tie between the satellite ground track and the laser, (3) a tide gauge on a tower at-sea with satellite positioning from multiple lasers and a GPS, and (4) a laser and a tide gauge on a tower at-sea. Error budgets for these techniques, developed on the basis of state-of-the-art tracking systems, were found to have one sigma height uncertainties in the 2.8 to 4.9 cm range.

  5. NVLAP calibration laboratory program

    SciTech Connect

    Cigler, J.L.

    1993-12-31

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST).

  6. Computerized tomography calibrator

    NASA Technical Reports Server (NTRS)

    Engel, Herbert P. (Inventor)

    1991-01-01

    A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.

  7. Calibration Of Oxygen Monitors

    NASA Technical Reports Server (NTRS)

    Zalenski, M. A.; Rowe, E. L.; Mcphee, J. R.

    1988-01-01

    Readings corrected for temperature, pressure, and humidity of air. Program for handheld computer developed to ensure accuracy of oxygen monitors in National Transonic Facility, where liquid nitrogen stored. Calibration values, determined daily, based on entries of data on barometric pressure, temperature, and relative humidity. Output provided directly in millivolts.

  8. Pleiades Absolute Calibration : Inflight Calibration Sites and Methodology

    NASA Astrophysics Data System (ADS)

    Lachérade, S.; Fourest, S.; Gamet, P.; Lebègue, L.

    2012-07-01

    In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station) and Oceans (Calibration over molecular scattering) or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  9. Rapid synthesis of beta zeolites

    SciTech Connect

    Fan, Wei; Chang, Chun -Chih; Dornath, Paul; Wang, Zhuopeng

    2015-08-18

    The invention provides methods for rapidly synthesizing heteroatom containing zeolites including Sn-Beta, Si-Beta, Ti-Beta, Zr-Beta and Fe-Beta. The methods for synthesizing heteroatom zeolites include using well-crystalline zeolite crystals as seeds and using a fluoride-free, caustic medium in a seeded dry-gel conversion method. The Beta zeolite catalysts made by the methods of the invention catalyze both isomerization and dehydration reactions.

  10. Simplified Vicarious Radiometric Calibration

    NASA Technical Reports Server (NTRS)

    Stanley, Thomas; Ryan, Robert; Holekamp, Kara; Pagnutti, Mary

    2010-01-01

    A measurement-based radiance estimation approach for vicarious radiometric calibration of spaceborne multispectral remote sensing systems has been developed. This simplified process eliminates the use of radiative transfer codes and reduces the number of atmospheric assumptions required to perform sensor calibrations. Like prior approaches, the simplified method involves the collection of ground truth data coincident with the overpass of the remote sensing system being calibrated, but this approach differs from the prior techniques in both the nature of the data collected and the manner in which the data are processed. In traditional vicarious radiometric calibration, ground truth data are gathered using ground-viewing spectroradiometers and one or more sun photometer( s), among other instruments, located at a ground target area. The measured data from the ground-based instruments are used in radiative transfer models to estimate the top-of-atmosphere (TOA) target radiances at the time of satellite overpass. These TOA radiances are compared with the satellite sensor readings to radiometrically calibrate the sensor. Traditional vicarious radiometric calibration methods require that an atmospheric model be defined such that the ground-based observations of solar transmission and diffuse-to-global ratios are in close agreement with the radiative transfer code estimation of these parameters. This process is labor-intensive and complex, and can be prone to errors. The errors can be compounded because of approximations in the model and inaccurate assumptions about the radiative coupling between the atmosphere and the terrain. The errors can increase the uncertainty of the TOA radiance estimates used to perform the radiometric calibration. In comparison, the simplified approach does not use atmospheric radiative transfer models and involves fewer assumptions concerning the radiative transfer properties of the atmosphere. This new technique uses two neighboring uniform

  11. Imaging alpha particle detector

    DOEpatents

    Anderson, D.F.

    1980-10-29

    A method and apparatus for detecting and imaging alpha particles sources is described. A dielectric coated high voltage electrode and a tungsten wire grid constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source to be quantitatively or qualitatively analyzed. A thin polyester film window allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  12. Imaging alpha particle detector

    DOEpatents

    Anderson, David F.

    1985-01-01

    A method and apparatus for detecting and imaging alpha particles sources is described. A conducting coated high voltage electrode (1) and a tungsten wire grid (2) constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source (3) to be quantitatively or qualitatively analyzed. A thin polyester film window (4) allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  13. Three-view stereoscopy in dusty plasmas under microgravity: A calibration and reconstruction approach

    SciTech Connect

    Himpel, Michael; Buttenschoen, Birger; Melzer, Andre

    2011-05-15

    A three-camera stereoscopy setup is presented that allows to reconstruct the trajectories of particles in dusty plasmas under microgravity. The calibration procedure for the three-camera setup takes the special circumstances into account that occur in close-range imaging of small particles. Additionally, a reconstruction algorithm is presented that is based on the epipolar geometry and delivers the essential particle correspondences. Further improvements are achieved by analyzing the dynamic particle behavior. Two applications of our calibration and reconstruction procedure are presented: A two-dimensional dust structure in the laboratory with a large percentage of hidden particles, and particles inside the void of a dust cloud under microgravity.

  14. Mercury CEM Calibration

    SciTech Connect

    John F. Schabron; Joseph F. Rovani; Susan S. Sorini

    2007-03-31

    The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005, requires that calibration of mercury continuous emissions monitors (CEMs) be performed with NIST-traceable standards. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The traceability protocol will be written by EPA. Traceability will be based on the actual analysis of the output of each calibration unit at several concentration levels ranging from about 2-40 ug/m{sup 3}, and this analysis will be directly traceable to analyses by NIST using isotope dilution inductively coupled plasma/mass spectrometry (ID ICP/MS) through a chain of analyses linking the calibration unit in the power plant to the NIST ID ICP/MS. Prior to this project, NIST did not provide a recommended mercury vapor pressure equation or list mercury vapor pressure in its vapor pressure database. The NIST Physical and Chemical Properties Division in Boulder, Colorado was subcontracted under this project to study the issue in detail and to recommend a mercury vapor pressure equation that the vendors of mercury vapor pressure calibration units can use to calculate the elemental mercury vapor concentration in an equilibrium chamber at a particular temperature. As part of this study, a preliminary evaluation of calibration units from five vendors was made. The work was performed by NIST in Gaithersburg, MD and Joe Rovani from WRI who traveled to NIST as a Visiting Scientist.

  15. Uncertainty and calibration analysis

    SciTech Connect

    Coutts, D.A.

    1991-03-01

    All measurements contain some deviation from the true value which is being measured. In the common vernacular this deviation between the true value and the measured value is called an inaccuracy, an error, or a mistake. Since all measurements contain errors, it is necessary to accept that there is a limit to how accurate a measurement can be. The undertainty interval combined with the confidence level, is one measure of the accuracy for a measurement or value. Without a statement of uncertainty (or a similar parameter) it is not possible to evaluate if the accuracy of the measurement, or data, is appropriate. The preparation of technical reports, calibration evaluations, and design calculations should consider the accuracy of measurements and data being used. There are many methods to accomplish this. This report provides a consistent method for the handling of measurement tolerances, calibration evaluations and uncertainty calculations. The SRS Quality Assurance (QA) Program requires that the uncertainty of technical data and instrument calibrations be acknowledged and estimated. The QA Program makes some specific technical requirements related to the subject but does not provide a philosophy or method on how uncertainty should be estimated. This report was prepared to provide a technical basis to support the calculation of uncertainties and the calibration of measurement and test equipment for any activity within the Experimental Thermal-Hydraulics (ETH) Group. The methods proposed in this report provide a graded approach for estimating the uncertainty of measurements, data, and calibrations. The method is based on the national consensus standard, ANSI/ASME PTC 19.1.

  16. aCORN Beta Spectrometer and Electrostatic Mirror

    NASA Astrophysics Data System (ADS)

    Hassan, Md; aCORN Collaboration

    2013-10-01

    aCORN uses a high efficiency backscatter suppressed beta spectrometer to measure the electron-antineutrino correlation in neutron beta decay. We measure the correlation by counting protons and beta electrons in coincidence with precisely determined electron energy. There are 19 photomultiplier tubes arranged in a hexagonal array coupled to a single phosphor doped polystyrene scintillator. The magnetic field is shaped so that electrons that backscatter without depositing their full energy strike a tulip-shaped array of scintillator paddles and these events are vetoed. The detailed construction, performance and calibration of this beta spectrometer will be presented. I will also present the simulation, construction, and features of our novel electrostatic mirror. This work was supported by the National Science Foundation and the NIST Center for Neutron Research.

  17. Mercury Calibration System

    SciTech Connect

    John Schabron; Eric Kalberer; Joseph Rovani; Mark Sanderson; Ryan Boysen; William Schuster

    2009-03-11

    U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on

  18. Development of an alpha/beta/gamma detector for radiation monitoring

    SciTech Connect

    Yamamoto, Seiichi; Hatazawa, Jun

    2011-11-15

    For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd{sub 2}SiO{sub 5} (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required.

  19. Ureidopenicillins and beta-lactam/beta-lactamase inhibitor combinations.

    PubMed

    Bush, L M; Johnson, C C

    2000-06-01

    Although research and development of new penicillins have declined, penicillins continue to be essential antibiotics for the treatment and prophylaxis of infectious diseases. The most recent additions are the ureidopenicillins and beta-lactam/beta-lactamase inhibitor combinations. This article reviews the spectrum of activity, toxicity, pharmacokinetics, and clinical uses of the ureidopenicillins, and the beta-lactam/beta-lactamase inhibitor combination agents.

  20. The Calibration Reference Data System

    NASA Astrophysics Data System (ADS)

    Greenfield, P.; Miller, T.

    2016-07-01

    We describe a software architecture and implementation for using rules to determine which calibration files are appropriate for calibrating a given observation. This new system, the Calibration Reference Data System (CRDS), replaces what had been previously used for the Hubble Space Telescope (HST) calibration pipelines, the Calibration Database System (CDBS). CRDS will be used for the James Webb Space Telescope (JWST) calibration pipelines, and is currently being used for HST calibration pipelines. CRDS can be easily generalized for use in similar applications that need a rules-based system for selecting the appropriate item for a given dataset; we give some examples of such generalizations that will likely be used for JWST. The core functionality of the Calibration Reference Data System is available under an Open Source license. CRDS is briefly contrasted with a sampling of other similar systems used at other observatories.

  1. A webcam photogrammetric method for robot calibration

    NASA Astrophysics Data System (ADS)

    Sargeant, Ben; Hosseininaveh, Ali A.; Erfani, Tohid; Robson, Stuart; Boehm, Jan

    2013-04-01

    This paper describes a strategy for accurate robot calibration using close range photogrammetry. A 5-DoF robot has been designed for placement of two web cameras relative to an object. To ensure correct camera positioning, the robot is calibrated using the following strategy. First, a Denavit-Hartenberg method is used to generate a general kinematic robot model. A set of reference frames are defined relative to each joint and each of the cameras, transformation matrices are then produced to represent change in position and orientation between frames in terms of joint positions and unknown parameters. The complete model is extracted by multiplying these matrices. Second, photogrammetry is used to estimate the postures of both cameras. A set of images are captured of a calibration fixture from different robot poses. The camera postures are then estimated using bundle adjustment. Third, the kinematic parameters are estimated using weighted least squares. For each pose a set of equations are extracted from the model and the unknown parameters are estimated in an iterative procedure. Finally these values are substituted back into the original model. This final model is tested using forward kinematics by comparing the model's predicted camera postures for given joint positions to the values obtained through photogrammetry. Inverse kinematics is performed using both least squares and particle swarm optimisation and these techniques are contrasted. Results demonstrate that this photogrammetry approach produces a reliable and accurate model of the robot that can be used with both least squares and particle swarm optimisation for robot control.

  2. Multivariate Regression with Calibration*

    PubMed Central

    Liu, Han; Wang, Lie; Zhao, Tuo

    2014-01-01

    We propose a new method named calibrated multivariate regression (CMR) for fitting high dimensional multivariate regression models. Compared to existing methods, CMR calibrates the regularization for each regression task with respect to its noise level so that it is simultaneously tuning insensitive and achieves an improved finite-sample performance. Computationally, we develop an efficient smoothed proximal gradient algorithm which has a worst-case iteration complexity O(1/ε), where ε is a pre-specified numerical accuracy. Theoretically, we prove that CMR achieves the optimal rate of convergence in parameter estimation. We illustrate the usefulness of CMR by thorough numerical simulations and show that CMR consistently outperforms other high dimensional multivariate regression methods. We also apply CMR on a brain activity prediction problem and find that CMR is as competitive as the handcrafted model created by human experts. PMID:25620861

  3. Phase calibration generator

    NASA Technical Reports Server (NTRS)

    Sigman, E. H.

    1988-01-01

    A phase calibration system was developed for the Deep Space Stations to generate reference microwave comb tones which are mixed in with signals received by the antenna. These reference tones are used to remove drifts of the station's receiving system from the detected data. This phase calibration system includes a cable stabilizer which transfers a 20 MHz reference signal from the control room to the antenna cone. The cable stabilizer compensates for delay changes in the long cable which connects its control room subassembly to its antenna cone subassembly in such a way that the 20 MHz is transferred to the cone with no significant degradation of the hydrogen maser atomic clock stability. The 20 MHz reference is used by the comb generator and is also available for use as a reference for receiver LO's in the cone.

  4. Environmental calibration chamber operations

    NASA Technical Reports Server (NTRS)

    Lester, D. L.

    1988-01-01

    Thermal vacuum capabilities are provided for the development, calibration, and functional operation checks of flight sensors, sources, and laboratory and field instruments. Two systems are available. The first is a 46 cm diameter diffusion pumped vacuum chambler of the bell jar variety. It has an internal thermal shroud, LN2 old trap, two viewing ports, and various electrical and fluid feedthroughs. The other, also an oil diffusion pumped system, consists of a 1.8 m diameter by 2.5 m long stainless steel vacuum tank, associated pumping and control equipment, a liquid nitrogen storage and transfer system and internal IR/visible calibration sources. This is a two story system with the chamber located on one floor and the pumping/cryogenic systems located on the floor below.

  5. Calibrated vapor generator source

    DOEpatents

    Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.

    1995-09-26

    A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.

  6. Calibrated vapor generator source

    DOEpatents

    Davies, John P.; Larson, Ronald A.; Goodrich, Lorenzo D.; Hall, Harold J.; Stoddard, Billy D.; Davis, Sean G.; Kaser, Timothy G.; Conrad, Frank J.

    1995-01-01

    A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet.

  7. Automatic volume calibration system

    SciTech Connect

    Gates, A.J.; Aaron, C.C.

    1985-05-06

    The Automatic Volume Calibration System presently consists of three independent volume-measurement subsystems and can possibly be expanded to five subsystems. When completed, the system will manually or automatically perform the sequence of valve-control and data-acquisition operations required to measure given volumes. An LSI-11 minicomputer controls the vacuum and pressure sources and controls solenoid control valves to open and close various volumes. The input data are obtained from numerous displacement, temperature, and pressure sensors read by the LSI-11. The LSI-11 calculates the unknown volume from the data acquired during the sequence of valve operations. The results, based on the Ideal Gas Law, also provide information for feedback and control. This paper describes the volume calibration system, its subsystems, and the integration of the various instrumentation used in the system's design and development. 11 refs., 13 figs., 4 tabs.

  8. Fast calibration of gas flowmeters

    NASA Technical Reports Server (NTRS)

    Lisle, R. V.; Wilson, T. L.

    1981-01-01

    Digital unit automates calibration sequence using calculator IC and programmable read-only memory to solve calibration equations. Infrared sensors start and stop calibration sequence. Instrument calibrates mass flowmeters or rotameters where flow measurement is based on mass or volume. This automatic control reduces operator time by 80 percent. Solid-state components are very reliable, and digital character allows system accuracy to be determined primarily by accuracy of transducers.

  9. Calibration of Germanium Resistance Thermometers

    NASA Technical Reports Server (NTRS)

    Ladner, D.; Urban, E.; Mason, F. C.

    1987-01-01

    Largely completed thermometer-calibration cryostat and probe allows six germanium resistance thermometers to be calibrated at one time at superfluid-helium temperatures. In experiments involving several such thermometers, use of this calibration apparatus results in substantial cost savings. Cryostat maintains temperature less than 2.17 K through controlled evaporation and removal of liquid helium from Dewar. Probe holds thermometers to be calibrated and applies small amount of heat as needed to maintain precise temperature below 2.17 K.

  10. Mesoscale hybrid calibration artifact

    DOEpatents

    Tran, Hy D.; Claudet, Andre A.; Oliver, Andrew D.

    2010-09-07

    A mesoscale calibration artifact, also called a hybrid artifact, suitable for hybrid dimensional measurement and the method for make the artifact. The hybrid artifact has structural characteristics that make it suitable for dimensional measurement in both vision-based systems and touch-probe-based systems. The hybrid artifact employs the intersection of bulk-micromachined planes to fabricate edges that are sharp to the nanometer level and intersecting planes with crystal-lattice-defined angles.

  11. Calibration of hydrometers

    NASA Astrophysics Data System (ADS)

    Lorefice, Salvatore; Malengo, Andrea

    2006-10-01

    After a brief description of the different methods employed in periodic calibration of hydrometers used in most cases to measure the density of liquids in the range between 500 kg m-3 and 2000 kg m-3, particular emphasis is given to the multipoint procedure based on hydrostatic weighing, known as well as Cuckow's method. The features of the calibration apparatus and the procedure used at the INRiM (formerly IMGC-CNR) density laboratory have been considered to assess all relevant contributions involved in the calibration of different kinds of hydrometers. The uncertainty is strongly dependent on the kind of hydrometer; in particular, the results highlight the importance of the density of the reference buoyant liquid, the temperature of calibration and the skill of operator in the reading of the scale in the whole assessment of the uncertainty. It is also interesting to realize that for high-resolution hydrometers (division of 0.1 kg m-3), the uncertainty contribution of the density of the reference liquid is the main source of the total uncertainty, but its importance falls under about 50% for hydrometers with a division of 0.5 kg m-3 and becomes somewhat negligible for hydrometers with a division of 1 kg m-3, for which the reading uncertainty is the predominant part of the total uncertainty. At present the best INRiM result is obtained with commercially available hydrometers having a scale division of 0.1 kg m-3, for which the relative uncertainty is about 12 × 10-6.

  12. Calibrated Properties Model

    SciTech Connect

    H. H. Liu

    2003-02-14

    This report has documented the methodologies and the data used for developing rock property sets for three infiltration maps. Model calibration is necessary to obtain parameter values appropriate for the scale of the process being modeled. Although some hydrogeologic property data (prior information) are available, these data cannot be directly used to predict flow and transport processes because they were measured on scales smaller than those characterizing property distributions in models used for the prediction. Since model calibrations were done directly on the scales of interest, the upscaling issue was automatically considered. On the other hand, joint use of data and the prior information in inversions can further increase the reliability of the developed parameters compared with those for the prior information. Rock parameter sets were developed for both the mountain and drift scales because of the scale-dependent behavior of fracture permeability. Note that these parameter sets, except those for faults, were determined using the 1-D simulations. Therefore, they cannot be directly used for modeling lateral flow because of perched water in the unsaturated zone (UZ) of Yucca Mountain. Further calibration may be needed for two- and three-dimensional modeling studies. As discussed above in Section 6.4, uncertainties for these calibrated properties are difficult to accurately determine, because of the inaccuracy of simplified methods for this complex problem or the extremely large computational expense of more rigorous methods. One estimate of uncertainty that may be useful to investigators using these properties is the uncertainty used for the prior information. In most cases, the inversions did not change the properties very much with respect to the prior information. The Output DTNs (including the input and output files for all runs) from this study are given in Section 9.4.

  13. Beta experiment flight report

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A focused laser Doppler velocimeter system was developed for the measurement of atmospheric backscatter (beta) from aerosols at infrared wavelengths. The system was flight tested at several different locations and the results of these tests are summarized.

  14. TIME CALIBRATED OSCILLOSCOPE SWEEP

    DOEpatents

    Owren, H.M.; Johnson, B.M.; Smith, V.L.

    1958-04-22

    The time calibrator of an electric signal displayed on an oscilloscope is described. In contrast to the conventional technique of using time-calibrated divisions on the face of the oscilloscope, this invention provides means for directly superimposing equal time spaced markers upon a signal displayed upon an oscilloscope. More explicitly, the present invention includes generally a generator for developing a linear saw-tooth voltage and a circuit for combining a high-frequency sinusoidal voltage of a suitable amplitude and frequency with the saw-tooth voltage to produce a resultant sweep deflection voltage having a wave shape which is substantially linear with respect to time between equal time spaced incremental plateau regions occurring once each cycle of the sinusoidal voltage. The foregoing sweep voltage when applied to the horizontal deflection plates in combination with a signal to be observed applied to the vertical deflection plates of a cathode ray oscilloscope produces an image on the viewing screen which is essentially a display of the signal to be observed with respect to time. Intensified spots, or certain other conspicuous indications corresponding to the equal time spaced plateau regions of said sweep voltage, appear superimposed upon said displayed signal, which indications are therefore suitable for direct time calibration purposes.

  15. Calibrated Properties Model

    SciTech Connect

    T. Ghezzehej

    2004-10-04

    The purpose of this model report is to document the calibrated properties model that provides calibrated property sets for unsaturated zone (UZ) flow and transport process models (UZ models). The calibration of the property sets is performed through inverse modeling. This work followed, and was planned in, ''Technical Work Plan (TWP) for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Sections 1.2.6 and 2.1.1.6). Direct inputs to this model report were derived from the following upstream analysis and model reports: ''Analysis of Hydrologic Properties Data'' (BSC 2004 [DIRS 170038]); ''Development of Numerical Grids for UZ Flow and Transport Modeling'' (BSC 2004 [DIRS 169855]); ''Simulation of Net Infiltration for Present-Day and Potential Future Climates'' (BSC 2004 [DIRS 170007]); ''Geologic Framework Model'' (GFM2000) (BSC 2004 [DIRS 170029]). Additionally, this model report incorporates errata of the previous version and closure of the Key Technical Issue agreement TSPAI 3.26 (Section 6.2.2 and Appendix B), and it is revised for improved transparency.

  16. Calibration of MICROSCOPE

    NASA Astrophysics Data System (ADS)

    Guiu, E.; Rodrigues, M.; Touboul, P.; Pradels, G.

    The MICROSCOPE mission is planned for launch in early 2009. It aims to verify the Equivalence Principle to an accuracy of 10-15, which is currently difficult to obtain on Earth because of the intrinsic limitations of the torsion pendulum and disturbing phenomena, like seismic activity. In space the experiment can take advantage of the quiet environment provided by a drag-free satellite. The instrument used for the test is a differential electrostatic accelerometer composed of two inertial sensors with test-masses made of different materials: one in Platinum Rhodium alloy, the other in Titanium alloy. The space experiment will also benefit from a second differential accelerometer with both test-masses of the same material, which will be used as a reference instrument to characterise the disturbing signals and sensitivities. The in-orbit calibration of the instrument is mandatory to validate the space test and several procedures have been previously proposed, taking advantage of the satellite propulsion system or the a priori knowledge of natural in-orbit applied accelerations. Due to the actual configuration of the MICROSCOPE propulsion system, the possibility of accurate satellite manoeuvres is limited but sufficient. This paper presents the necessary compromise between the knowledge of satellite and instrument parameters and the calibration procedures. The scenario of the MICROSCOPE in-orbit calibration phase is finely defined in agreement with the required performances for the EP test accuracy.

  17. Traceable periodic force calibration

    NASA Astrophysics Data System (ADS)

    Schlegel, Ch; Kieckenap, G.; Glöckner, B.; Buß, A.; Kumme, R.

    2012-06-01

    A procedure for dynamic force calibration using sinusoidal excitations of force transducers is described. The method is based on a sinusoidal excitation of force transducers equipped with an additional top mass excited with an electrodynamic shaker system. The acting dynamic force can in this way be determined according to Newton's law as mass times acceleration, whereby the acceleration is measured on the surface of the top mass with the aid of laser interferometers. The dynamic sensitivity, which is the ratio of the electrical output signal of the force transducer and the acting dynamic force, is the main point of interest of such a dynamic calibration. In addition to the sensitivity, the parameter stiffness and damping of the transducer can also be determined. The first part of the paper outlines a mathematical model to describe the dynamic behaviour of a transducer. This is followed by a presentation of the traceability of the measured quantities involved and their uncertainties. The paper finishes with an example calibration of a 25 kN strain gauge force transducer.

  18. Radiation calibration targets

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Several prominent features of Mars Pathfinder and surrounding terrain are seen in this image, taken by the Imager for Mars Pathfinder on July 4 (Sol 1), the spacecraft's first day on the Red Planet. Portions of a lander petal are at the lower part of the image. At the left, the mechanism for the high-gain antenna can be seen. The dark area along the right side of the image represents a portion of the low-gain antenna. The radiation calibration target is at the right. The calibration target is made up of a number of materials with well-characterized colors. The known colors of the calibration targets allow scientists to determine the true colors of the rocks and soils of Mars. Three bull's-eye rings provide a wide range of brightness for the camera, similar to a photographer's grayscale chart. In the middle of the bull's-eye is a 5-inch tall post that casts a shadow, which is distorted in this image due to its location with respect to the lander camera.

    A large rock is located at the near center of the image. Smaller rocks and areas of soil are strewn across the Martian terrain up to the horizon line.

    Mars Pathfinder is the second in NASA's Discovery program of low-cost spacecraft with highly focused science goals. The Jet Propulsion Laboratory, Pasadena, CA, developed and manages the Mars Pathfinder mission for NASA's Office of Space Science, Washington, D.C.

  19. Detonation Shock Dynamics Calibration for Non-Ideal HE: ANFO

    NASA Astrophysics Data System (ADS)

    Short, Mark; Salyer, Terry

    2009-06-01

    The detonation of ammonium nitrate (AN) and fuel-oil (FO) mixtures (ANFO) is significantly influenced by the properties of the AN (porosity, particle size, coating) and fuel-oil stoichiometry. We report on a new series of rate-stick experiments in cardboard confinement that highlight detonation front speed and curvature dependence on AN/FO stoichiometry and AN particle properties. Standard detonation velocity-curvature calibrations to the experimental data will be presented, as well as higher-order time-dependent detonation shock dynamics calibrations.

  20. Improved dewpoint-probe calibration

    NASA Technical Reports Server (NTRS)

    Stephenson, J. G.; Theodore, E. A.

    1978-01-01

    Relatively-simple pressure-control apparatus calibrates dewpoint probes considerably faster than conventional methods, with no loss of accuracy. Technique requires only pressure measurement at each calibration point and single absolute-humidity measurement at beginning of run. Several probes can be calibrated simultaneously and points can be checked above room temperature.

  1. Dynamic Calibration of Pressure Transducers

    NASA Technical Reports Server (NTRS)

    Hess, R. W.; Davis, W. T.; Davis, P. A.

    1985-01-01

    Sinusoidal calibration signal produced in 4- to 100-Hz range. Portable oscillating-pressure device measures dynamic characteristics of pressure transducers installed in models or aircraft at frequency and oscillating-pressure ranges encountered during unsteady-pressure-measurement tests. Calibration is over range of frequencies and amplitudes not available with commercial acoustic calibration devices.

  2. High beta multipoles

    SciTech Connect

    Prager, S C

    1982-05-01

    Multipoles are being employed as devices to study fusion issues and plasma phenomena at high values of beta (plasma pressure/magnetic pressure) in a controlled manner. Due to their large volume, low magnetic field (low synchrotron radiation) region, they are also under consideration as potential steady state advanced fuel (low neutron yield) reactors. Present experiments are investigating neoclassical (bootstrap and Pfirsch-Schlueter) currents and plasma stability at extremely high beta.

  3. Calibration and Use of the Canberra iSolo 300G

    SciTech Connect

    Smith, T; Graham, C L; Sundsmo, T; Shingleton, K L

    2010-11-24

    This procedure provides instructions for the calibration and use of the Canberra iSolo Low Background Alpha/Beta Counting System (iSolo) that is used for counting air filters and swipe samples. This detector is capable of providing radioisotope identification (e.g., it can discriminate between radon daughters and plutonium). This procedure includes step-by-step instructions for: (1) Performing periodic or daily 'Background' and 'Efficiency QC' checks; (2) Setting-up the iSolo for counting swipes and air filters; (3) Counting swipes and air filters for alpha and beta activity; and (4) Annual calibration.

  4. PBX: the Princeton beta experiment

    SciTech Connect

    Bol, K.; Chance, M.; Dewar, R.

    1983-09-01

    A rearrangement of the divertor coils in PDX will enable a test in 1984 of the MHD stability properties of deeply indented bean-shaped plasmas. The goal is a beta of 10%. Indentation is expected to counter the deterioration of MHD stability against pressure driven modes that is occasioned by the larger aspect ratios typical of anticipated reactor oriented devices. Indeed, as shown by M. Chance et al., indentation may offer direct access to the second region of stability for ballooning modes, and numerical analyses with PEST show the internal kink to be stabilized completely with even relatively modest indentation. The internal kink is implicated in the loss of beam ions in PDX. In this report the theoretical basis for the forthcoming experiment, and the design considerations underlying the modification from PDX to PBX, are described in detail. Additional theoretical material, including an analysis of particle orbits in an indented tokamak plasma, is appended.

  5. Internet-based calibration of a multifunction calibrator

    SciTech Connect

    BUNTING BACA,LISA A.; DUDA JR.,LEONARD E.; WALKER,RUSSELL M.; OLDHAM,NILE; PARKER,MARK

    2000-04-17

    A new way of providing calibration services is evolving which employs the Internet to expand present capabilities and make the calibration process more interactive. Sandia National Laboratories and the National Institute of Standards and Technology are collaborating to set up and demonstrate a remote calibration of multifunction calibrators using this Internet-based technique that is becoming known as e-calibration. This paper describes the measurement philosophy and the Internet resources that can provide real-time audio/video/data exchange, consultation and training, as well as web-accessible test procedures, software and calibration reports. The communication system utilizes commercial hardware and software that should be easy to integrate into most calibration laboratories.

  6. Internet-Based Calibration of a Multifunction Calibrator

    SciTech Connect

    BUNTING BACA,LISA A.; DUDA JR.,LEONARD E.; WALKER,RUSSELL M.; OLDHAM,NILE; PARKER,MARK

    2000-12-19

    A new way of providing calibration services is evolving which employs the Internet to expand present capabilities and make the calibration process more interactive. Sandia National Laboratories and the National Institute of Standards and Technology are collaborating to set up and demonstrate a remote calibration of multijunction calibrators using this Internet-based technique that is becoming known as e-calibration. This paper describes the measurement philosophy and the Internet resources that can provide real-time audio/video/data exchange, consultation and training, as well as web-accessible test procedures, software and calibration reports. The communication system utilizes commercial hardware and software that should be easy to integrate into most calibration laboratories.

  7. Use of rotating pinholes and reticles for calibration of cloud droplet instrumentation

    NASA Technical Reports Server (NTRS)

    Hovenac, Edward A.; Hirleman, E. Dan

    1991-01-01

    Calibration devices for the Forward Scattering Spectrometer Probe (FSSP) and the Optical Array Probe (OAP) were developed. The device used with the FSSP is a rotating pinhole calibrator. It utilizes light diffracted by a pinhole of a known diameter to simulate scattered light from a water droplet. This device can be used to calibrate the FSSP, measure the FSSP's optical collection angles and for instrument alignment and troubleshooting. The device used with the OAP is a rotating reticle calibrator. Chrome disks of a known diameter on the reticle are used for calibration of the OAP and for determining the OAP's response to out-of-focus particles in the probe volume.

  8. Calibration system for radon EEC measurements.

    PubMed

    Mostafa, Y A M; Vasyanovich, M; Zhukovsky, M; Zaitceva, N

    2015-06-01

    The measurement of radon equivalent equilibrium concentration (EECRn) is very simple and quick technique for the estimation of radon progeny level in dwellings or working places. The most typical methods of EECRn measurements are alpha radiometry or alpha spectrometry. In such technique, the influence of alpha particle absorption in filters and filter effectiveness should be taken into account. In the authors' work, it is demonstrated that more precise and less complicated calibration of EECRn-measuring equipment can be conducted by the use of the gamma spectrometer as a reference measuring device. It was demonstrated that for this calibration technique systematic error does not exceed 3 %. The random error of (214)Bi activity measurements is in the range 3-6 %. In general, both these errors can be decreased. The measurements of EECRn by gamma spectrometry and improved alpha radiometry are in good agreement, but the systematic shift between average values can be observed. PMID:25979737

  9. Standoff determination of the particle size and concentration of small optical depth clouds based on double-scattering measurements: validation with calibrated target plates and limitations for daytime and nighttime measurements.

    PubMed

    Roy, Nathalie; Roy, Gilles

    2008-08-10

    Diffractive target plates are used to emulate aerosols of known size and concentration. These target plates are used to validate and determine the sensitivity of a multiple-field-of-view lidar signal inversion technique based on double-scattering measurement to retrieve the particle size and the concentration of small optical depth clouds. We estimate that nighttime and daytime quantification (size and concentration) is possible for optical depths as low as 0.005 and 0.016, respectively. The recovery technique limiting factors are the shot noise, the laser features, the optical lens quality, the background illumination level, the background aerosol fluctuations, and the noise introduced by the lidar detector, a gated intensified camera (camera G-ICCD).

  10. Cosmology with decaying particles

    SciTech Connect

    Turner, M.S.

    1984-09-01

    We consider a cosmological model in which an unstable massive relic particle species (denoted by X) has an initial mass density relative to baryons ..beta../sup -1/ identically equal rho/sub X//rho/sub B/ >> 1, and then decays recently (redshift z less than or equal to 1000) into particles which are still relativistic today (denoted by R). We write down and solve the coupled equations for the cosmic scale factor a(t), the energy density in the various components (rho/sub X/, rho/sub R/, rho/sub B/), and the growth of linear density perturbations (delta rho/rho). The solutions form a one parameter (..beta..) family of solutions; physically ..beta../sup -1/ approx. = (..cap omega../sub R//..cap omega../sub NR/) x (1 + z/sub D/) = (ratio today of energy density of relativistic to nonrelativistic particles) x (1 + redshift of (decay)). We discuss the observational implications of such a cosmological model and compare our results to earlier results computed in the simultaneous decay approximation. In an appendix we briefly consider the case where one of the decay products of the X is massive and becomes nonrelativistic by the present epoch. 21 references.

  11. Calibration of triaxial fluxgate gradiometer

    SciTech Connect

    Vcelak, Jan

    2006-04-15

    The description of simple and fast calibration procedures used for double-probe triaxial fluxgate gradiometer is provided in this paper. The calibration procedure consists of three basic steps. In the first step both probes are calibrated independently in order to reach constant total field reading in every position. Both probes are numerically aligned in the second step in order that the gradient reading is zero in homogenous magnetic field. The third step consists of periodic drift calibration during measurement. The results and detailed description of each calibration step are presented and discussed in the paper. The gradiometer is finally verified during the detection of the metal object in the measuring grid.

  12. Characterization of the Basalt of Broken Tank, NM for the 'in situ' Calibration Target for the Alpha-Particle X-ray Spectrometer (APXS) on the Upcoming Mars Science Laboratory (MSL) Rover

    NASA Astrophysics Data System (ADS)

    Burkemper, L.; King, P. L.; Gellert, R.; Spilde, M. N.; Chamberlin, R. M.

    2008-12-01

    The MSL rover mission will launch in Fall 2009. It is equipped with an APXS for analyzing the bulk chemistry of rocks and soils. To monitor the APXS performance in situ on the martian surface over the extended mission, a calibration target will be included on the MSL rover. Engineering constraints led to a 4.2 cm diameter, 3 mm thick, homogeneous rock disc that would survive vibrations during launch. The basalt from Broken Tank, NM was chosen for the flight disc from ~200 volcanic rocks. The basalt is relatively homogeneous, fine- and even-grained, vesicle-free, and extremely dense and hard due to its ophitic texture. Other volcanic rocks - even well characterized samples of BCR - were ruled out due to vesicles, or high contents of glass, phenocrysts, secondary minerals, or fractures. The flight disc was prepared by hand- polishing to a 0.05 micron finish. We obtained scanning electron microscope back-scattered electron maps and X-ray maps (Al, Mg, Ca, Fe, Ti, Na, and K) on the polished, uncoated surface of the target. One pit (~0.03 mm2) and three tiny surface imperfections (<0.04 mm2) were observed on the surface. Electron microprobe analyses on two C-coated thin sections give the following compositions: olivine cores Fa23Fo77 and rims Fa40Fo60; plagioclase cores Ab42An56Or2 and discrete rims Ab62An7Or31; oxides Ilm67Hm33 and also trace chromite, apatite, chlorite, clays and devitrified glass. The NIH software Scion Image was used to determine the modal abundance of each phase in the basalt disk and in two thin sections. Bulk composition was established with multiple XRF laboratory analyses. There is no significant heterogeneity on the scale of the APXS analysis (~1.5 cm). Sulfides were not observed and XRF verified low Ni (<90 ppm) and S (70 ppm), making these elements ideal to monitor any Martian dust build-up during the surface operation. The rock slab is glued into a Ni frame, mounted vertically and accessible with a brush tool. The K- and L- X-ray lines of

  13. Mercury CEM Calibration

    SciTech Connect

    John Schabron; Joseph Rovani; Mark Sanderson

    2008-02-29

    Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The

  14. A variable acceleration calibration system

    NASA Astrophysics Data System (ADS)

    Johnson, Thomas H.

    2011-12-01

    A variable acceleration calibration system that applies loads using gravitational and centripetal acceleration serves as an alternative, efficient and cost effective method for calibrating internal wind tunnel force balances. Two proof-of-concept variable acceleration calibration systems are designed, fabricated and tested. The NASA UT-36 force balance served as the test balance for the calibration experiments. The variable acceleration calibration systems are shown to be capable of performing three component calibration experiments with an approximate applied load error on the order of 1% of the full scale calibration loads. Sources of error are indentified using experimental design methods and a propagation of uncertainty analysis. Three types of uncertainty are indentified for the systems and are attributed to prediction error, calibration error and pure error. Angular velocity uncertainty is shown to be the largest indentified source of prediction error. The calibration uncertainties using a production variable acceleration based system are shown to be potentially equivalent to current methods. The production quality system can be realized using lighter materials and a more precise instrumentation. Further research is needed to account for balance deflection, forcing effects due to vibration, and large tare loads. A gyroscope measurement technique is shown to be capable of resolving the balance deflection angle calculation. Long term research objectives include a demonstration of a six degree of freedom calibration, and a large capacity balance calibration.

  15. Self-Calibrating Pressure Transducer

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E. (Inventor)

    2006-01-01

    A self-calibrating pressure transducer is disclosed. The device uses an embedded zirconia membrane which pumps a determined quantity of oxygen into the device. The associated pressure can be determined, and thus, the transducer pressure readings can be calibrated. The zirconia membrane obtains oxygen .from the surrounding environment when possible. Otherwise, an oxygen reservoir or other source is utilized. In another embodiment, a reversible fuel cell assembly is used to pump oxygen and hydrogen into the system. Since a known amount of gas is pumped across the cell, the pressure produced can be determined, and thus, the device can be calibrated. An isolation valve system is used to allow the device to be calibrated in situ. Calibration is optionally automated so that calibration can be continuously monitored. The device is preferably a fully integrated MEMS device. Since the device can be calibrated without removing it from the process, reductions in costs and down time are realized.

  16. [Laser-based radiometric calibration].

    PubMed

    Li, Zhi-gang; Zheng, Yu-quan

    2014-12-01

    Increasingly higher demands are put forward to spectral radiometric calibration accuracy and the development of new tunable laser based spectral radiometric calibration technology is promoted, along with the development of studies of terrestrial remote sensing, aeronautical and astronautical remote sensing, plasma physics, quantitative spectroscopy, etc. Internationally a number of national metrology scientific research institutes have built tunable laser based spectral radiometric calibration facilities in succession, which are traceable to cryogenic radiometers and have low uncertainties for spectral responsivity calibration and characterization of detectors and remote sensing instruments in the UK, the USA, Germany, etc. Among them, the facility for spectral irradiance and radiance responsivity calibrations using uniform sources (SIRCCUS) at the National Institute of Standards and Technology (NIST) in the USA and the Tunable Lasers in Photometry (TULIP) facility at the Physikalisch-Technische Bundesanstalt (PTB) in Germany have more representatives. Compared with lamp-monochromator systems, laser based spectral radiometric calibrations have many advantages, such as narrow spectral bandwidth, high wavelength accuracy, low calibration uncertainty and so on for radiometric calibration applications. In this paper, the development of laser-based spectral radiometric calibration and structures and performances of laser-based radiometric calibration facilities represented by the National Physical Laboratory (NPL) in the UK, NIST and PTB are presented, technical advantages of laser-based spectral radiometric calibration are analyzed, and applications of this technology are further discussed. Laser-based spectral radiometric calibration facilities can be widely used in important system-level radiometric calibration measurements with high accuracy, including radiance temperature, radiance and irradiance calibrations for space remote sensing instruments, and promote the

  17. [Laser-based radiometric calibration].

    PubMed

    Li, Zhi-gang; Zheng, Yu-quan

    2014-12-01

    Increasingly higher demands are put forward to spectral radiometric calibration accuracy and the development of new tunable laser based spectral radiometric calibration technology is promoted, along with the development of studies of terrestrial remote sensing, aeronautical and astronautical remote sensing, plasma physics, quantitative spectroscopy, etc. Internationally a number of national metrology scientific research institutes have built tunable laser based spectral radiometric calibration facilities in succession, which are traceable to cryogenic radiometers and have low uncertainties for spectral responsivity calibration and characterization of detectors and remote sensing instruments in the UK, the USA, Germany, etc. Among them, the facility for spectral irradiance and radiance responsivity calibrations using uniform sources (SIRCCUS) at the National Institute of Standards and Technology (NIST) in the USA and the Tunable Lasers in Photometry (TULIP) facility at the Physikalisch-Technische Bundesanstalt (PTB) in Germany have more representatives. Compared with lamp-monochromator systems, laser based spectral radiometric calibrations have many advantages, such as narrow spectral bandwidth, high wavelength accuracy, low calibration uncertainty and so on for radiometric calibration applications. In this paper, the development of laser-based spectral radiometric calibration and structures and performances of laser-based radiometric calibration facilities represented by the National Physical Laboratory (NPL) in the UK, NIST and PTB are presented, technical advantages of laser-based spectral radiometric calibration are analyzed, and applications of this technology are further discussed. Laser-based spectral radiometric calibration facilities can be widely used in important system-level radiometric calibration measurements with high accuracy, including radiance temperature, radiance and irradiance calibrations for space remote sensing instruments, and promote the

  18. Use of Radiometrically Calibrated Flat-Plate Calibrators in Calibration of Radiation Thermometers

    NASA Astrophysics Data System (ADS)

    Cárdenas-García, D.; Méndez-Lango, E.

    2015-08-01

    Most commonly used, low-temperature, infrared thermometers have large fields of view sizes that make them difficult to be calibrated with narrow aperture blackbodies. Flat-plate calibrators with large emitting surfaces have been proposed for calibrating these infrared thermometers. Because the emissivity of the flat plate is not unity, its radiance temperature is wavelength dependent. For calibration, the wavelength pass band of the device under test should match that of the reference infrared thermometer. If the device under test and reference radiometer have different pass bands, then it is possible to calculate the corresponding correction if the emissivity of the flat plate is known. For example, a correction of at is required when calibrating a infrared thermometer with a "" radiometrically calibrated flat-plate calibrator. A method is described for using a radiometrically calibrated flat-plate calibrator that covers both cases of match and mismatch working wavelength ranges of a reference infrared thermometer and infrared thermometers to be calibrated with the flat-plate calibrator. Also, an application example is included in this paper.

  19. Calibration of the EPD sensors on Solar Orbiter

    NASA Astrophysics Data System (ADS)

    Wimmer-Schweingruber, Robert; Mason, Glenn; Ho, George; Boettcher, Stephan; Martin, Cesar; Kulkarni, Shrinivasrao; Sanchez Prieto, Sebastian; Rodriguez-Pacheco, Javier; Prieto, Manuel; Panitzsch, Lauri

    2016-07-01

    The Energetic Particle Detector (EPD) on Solar Orbiter will measure ions from a few keV/nuc up to hundred(s) of MeV/nuc (ion specific) and electrons from few keV to ~20 MeV to understand how solar eruptions produce energetic particle radiation that fills the heliosphere. This important question is one of the main scientific objectives of Solar Orbiter. The EPD sensors have undergone substantial calibration efforts which we will report in this presentation.

  20. Imaging plates calibration to X-rays

    NASA Astrophysics Data System (ADS)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  1. The MISR Calibration Program

    NASA Technical Reports Server (NTRS)

    Bruegge, Carol J.; Diner, David J.; Duval, Valerie G.

    1996-01-01

    The Multiangle Imaging SpectroRadiometer (MISR) is currently under development for NASA's Earth Observing System. The instrument consists of nine pushbroom cameras, each with four spectral bands in the visible and near-infrared. The cameras point in different view directions to provide measurements from nadir to highly oblique view angles in the along-track plane. Multiple view-angle observations provide a unique resource for studies of clouds, aerosols, and the surface. MISR is built to challenging radiometric and geometric performance specifications. Radiometric accuracy, for example, must be within +/- 3%/ 1 sigma, and polarization insensitivity must be better than +/- 1 %. An onboard calibrator (OBC) provides monthly updates to the instrument gain coefficients. Spectralon diffuse panels are used within the OBC to provide a uniform target for the cameras to view. The absolute radiometric scale is established both preflight and in orbit through the use of detector standards. During the mission, ground data processing to accomplish radiometric calibration, geometric rectification and registration of the nine view-angle imagery, and geophysical retrievals will proceed in an automated fashion. A global dataset is produced every 9 days. This paper details the preflight characterization of the MISR instrument, the design of the OBC, and the radiance product processing.

  2. A Simple Accelerometer Calibrator

    NASA Astrophysics Data System (ADS)

    Salam, R. A.; Islamy, M. R. F.; Munir, M. M.; Latief, H.; Irsyam, M.; Khairurrijal

    2016-08-01

    High possibility of earthquake could lead to the high number of victims caused by it. It also can cause other hazards such as tsunami, landslide, etc. In that case it requires a system that can examine the earthquake occurrence. Some possible system to detect earthquake is by creating a vibration sensor system using accelerometer. However, the output of the system is usually put in the form of acceleration data. Therefore, a calibrator system for accelerometer to sense the vibration is needed. In this study, a simple accelerometer calibrator has been developed using 12 V DC motor, optocoupler, Liquid Crystal Display (LCD) and AVR 328 microcontroller as controller system. The system uses the Pulse Wave Modulation (PWM) form microcontroller to control the motor rotational speed as response to vibration frequency. The frequency of vibration was read by optocoupler and then those data was used as feedback to the system. The results show that the systems could control the rotational speed and the vibration frequencies in accordance with the defined PWM.

  3. Assessment of opacimeter calibration on kraft pulp mills

    NASA Astrophysics Data System (ADS)

    Gomes, Joa˜o. F. P.

    This paper describes the methodology and specific techniques for calibrating automatic on-line industrial emission analysers, specifically equipments that measure total suspended dust installed in pulp mills within the scope of Portuguese Regulation No. 286/93 on air quality. The calibration of opacimeters is a multi-parameter relationship instead of the bidimensional calibration which is used in industrial practice. For a stationary source from a pulp mill such as the recovery boiler stack, which is subjected to significant variations, the effects of parameters such as the humidity and gas temperature, deviations of isokinetism, size range of particles and characteristic transmittance of equipment are analysed. The multivariable analysis of a considerable set of data leads to an estimate of about 98% of equipment transmittance over the other parameters with a level of significance greater than 0.99 which is a validation of the bidimensional practical calibrations.

  4. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    SciTech Connect

    Burns, R.E. Jr.; O`Brien, J.M. Jr.

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  5. Studies of total bremsstrahlung in thick targets of Al, Ti, Sn and Pb for 90Sr beta particles in the photon energy region of 1-100 keV

    NASA Astrophysics Data System (ADS)

    Singh, Amrit; Dhaliwal, A. S.

    2016-02-01

    Total bremsstrahlung (BS) spectra in thick targets of Al, Ti, Sn and Pb produced by beta emitter 90Sr (End point energy=546 keV) are studied in the photon energy range of 1-100 keV. The experimentally measured BS spectra are compared with the theoretical spectral distributions calculated from Elwert corrected (non relativistic) Bethe-Heitler [EBH] theory, modified Elwert factor (relativistic) Bethe-Heitler [Fmod BH] theory for ordinary bremsstrahlung (OB) and the Avdonina and Pratt [Fmod BH+PB] theory, which include the contribution of polarization bremsstrahlung (PB) into OB. The present results are indicating the correctness of Fmod BH+PB theory in the low energy region, where PB dominates into the BS, but at the middle and higher photon energy region of the bremsstrahlung spectrum, the Fmod BH theory is more close to the experimental results. The description of the bremsstrahlung process in stripped atom (SA) approximation, which indicates the suppression of the bremsstrahlung at higher energy ends due to the production of PB in the low energy region, needs further considerations. Hence, the present measurements for BS for different target materials indicates that the considerations of the screening effects along with other secondary effects during the interaction of incident electrons with the target nuclei are important while describing the production of bremsstrahlung, particularly for the higher energy regions.

  6. IO SUBSYSTEM 1 BETA

    2002-08-21

    "IO Subsystem Ver. 1.0 Beta" uses standard object-oriented principles to minimize dependencies between the underlying input or output database format and the client code (i.e., Sierra) using the io subsystem. The interface and priciples are simolar to the Facade pattern described in the "Design Patterns" book by Gamma, et.al. The software uses data authentication algorithms to ensure data input/output is consistent with model being defined. "IO Subsystem Ver. 1.0 Beta" is a database independent input/outputmore » library for finite element analysis, preprocessing, post processing, and translation programs.« less

  7. IO SUBSYSTEM 1 BETA

    SciTech Connect

    Sjaardema, Greg

    2002-08-21

    "IO Subsystem Ver. 1.0 Beta" uses standard object-oriented principles to minimize dependencies between the underlying input or output database format and the client code (i.e., Sierra) using the io subsystem. The interface and priciples are simolar to the Facade pattern described in the "Design Patterns" book by Gamma, et.al. The software uses data authentication algorithms to ensure data input/output is consistent with model being defined. "IO Subsystem Ver. 1.0 Beta" is a database independent input/output library for finite element analysis, preprocessing, post processing, and translation programs.

  8. In situ calibration of inductively coupled plasma-atomic emission and mass spectroscopy

    DOEpatents

    Braymen, S.D.

    1996-06-11

    A method and apparatus are disclosed for in situ addition calibration of an inductively coupled plasma atomic emission spectrometer or mass spectrometer using a precision gas metering valve to introduce a volatile calibration gas of an element of interest directly into an aerosol particle stream. The present in situ calibration technique is suitable for various remote, on-site sampling systems such as laser ablation or nebulization. 5 figs.

  9. NASA Metrology and Calibration, 1980

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The proceedings of the fourth annual NASA Metrology and Calibration Workshop are presented. This workshop covered (1) review and assessment of NASA metrology and calibration activities by NASA Headquarters, (2) results of audits by the Office of Inspector General, (3) review of a proposed NASA Equipment Management System, (4) current and planned field center activities, (5) National Bureau of Standards (NBS) calibration services for NASA, (6) review of NBS's Precision Measurement and Test Equipment Project activities, (7) NASA instrument loan pool operations at two centers, (8) mobile cart calibration systems at two centers, (9) calibration intervals and decals, (10) NASA Calibration Capabilities Catalog, and (11) development of plans and objectives for FY 1981. Several papers in this proceedings are slide presentations only.

  10. Calibration of neutron albedo dosemeters.

    PubMed

    Schwartz, R B; Eisenhauer, C M

    2002-01-01

    It is shown that by calibrating neutron albedo dosemeters under the proper conditions, two complicating effects will essentially cancel out, allowing accurate calibrations with no need for explicit corrections. The 'proper conditions' are: a large room (> or = 8 m on a side). use of a D2O moderated 252Cf source, and a source-to-phantom calibration distance of approximately 70 cm. PMID:12212898

  11. Final Report for DUSEL R&D: BetaCage: A Screener of Ultra-Low-Level Radioactive Surface Contamination

    SciTech Connect

    Golwala, Sunil R.

    2013-12-20

    The eventual full-size, radiopure BetaCage will be a low-background, atmospheric-pressure neon drift chamber with unprecedented sensitivity to emitters of low-energy electrons and alpha particles. We expect that the prototype BetaCage already developed will be an excellent screener of alpha particles. Both the prototype and final BetaCage will provide new infrastructure for rare-event science.

  12. Neural networks for calibration tomography

    NASA Technical Reports Server (NTRS)

    Decker, Arthur

    1993-01-01

    Artificial neural networks are suitable for performing pattern-to-pattern calibrations. These calibrations are potentially useful for facilities operations in aeronautics, the control of optical alignment, and the like. Computed tomography is compared with neural net calibration tomography for estimating density from its x-ray transform. X-ray transforms are measured, for example, in diffuse-illumination, holographic interferometry of fluids. Computed tomography and neural net calibration tomography are shown to have comparable performance for a 10 degree viewing cone and 29 interferograms within that cone. The system of tomography discussed is proposed as a relevant test of neural networks and other parallel processors intended for using flow visualization data.

  13. Calorimeters for pulsed lasers: calibration.

    PubMed

    Thacher, P D

    1976-07-01

    A calibration technique is developed and tested in which a calorimeter used for single-shot laser pulse energy measurements is calibrated with reference to a cw power standard using a chopped cw laser beam. A pulsed laser is required only to obtain the relative time response of the calorimeter to a pulse. With precautions as to beam alignment and wavelength, the principal error of the technique is that of the cw standard. Calibration of two thermopiles with cone receivers showed -2.5% and -3.5% agreement with previous calibrations made by the National Bureau of Standards. PMID:20165270

  14. Calibration Technique for Polarization-Sensitive Lidars

    NASA Technical Reports Server (NTRS)

    Alvarez, J. M.; Vaughan, M. A.; Hostetler, C. A.; Hung, W. H.; Winker, D. M.

    2006-01-01

    Polarization-sensitive lidars have proven to be highly effective in discriminating between spherical and non-spherical particles in the atmosphere. These lidars use a linearly polarized laser and are equipped with a receiver that can separately measure the components of the return signal polarized parallel and perpendicular to the outgoing beam. In this work we describe a technique for calibrating polarization-sensitive lidars that was originally developed at NASA s Langley Research Center (LaRC) and has been used continually over the past fifteen years. The procedure uses a rotatable half-wave plate inserted into the optical path of the lidar receiver to introduce controlled amounts of polarization cross-talk into a sequence of atmospheric backscatter measurements. Solving the resulting system of nonlinear equations generates the system calibration constants (gain ratio, G, and offset angle, theta) required for deriving calibrated measurements of depolarization ratio from the lidar signals. In addition, this procedure also determines the mean depolarization ratio within the region of the atmosphere that is analyzed. Simulations and error propagation studies show the method to be both reliable and well behaved. Operational details of the technique are illustrated using measurements obtained as part of Langley Research Center s participation in the First ISCCP Regional Experiment (FIRE).

  15. Quality Management and Calibration

    NASA Astrophysics Data System (ADS)

    Merkus, Henk G.

    Good specification of a product’s performance requires adequate characterization of relevant properties. Particulate products are usually characterized by some PSD, shape or porosity parameter(s). For proper characterization, adequate sampling, dispersion, and measurement procedures should be available or developed and skilful personnel should use appropriate, well-calibrated/qualified equipment. The characterization should be executed, in agreement with customers, in a wellorganized laboratory. All related aspects should be laid down in a quality handbook. The laboratory should provide proof for its capability to perform the characterization of stated products and/or reference materials within stated confidence limits. This can be done either by internal validation and audits or by external GLP accreditation.

  16. RX130 Robot Calibration

    NASA Astrophysics Data System (ADS)

    Fugal, Mario

    2012-10-01

    In order to create precision magnets for an experiment at Oak Ridge National Laboratory, a new reverse engineering method has been proposed that uses the magnetic scalar potential to solve for the currents necessary to produce the desired field. To make the magnet it is proposed to use a copper coated G10 form, upon which a drill, mounted on a robotic arm, will carve wires. The accuracy required in the manufacturing of the wires exceeds nominal robot capabilities. However, due to the rigidity as well as the precision servo motor and harmonic gear drivers, there are robots capable of meeting this requirement with proper calibration. Improving the accuracy of an RX130 to be within 35 microns (the accuracy necessary of the wires) is the goal of this project. Using feedback from a displacement sensor, or camera and inverse kinematics it is possible to achieve this accuracy.

  17. Atmospheric optical calibration system

    DOEpatents

    Hulstrom, Roland L.; Cannon, Theodore W.

    1988-01-01

    An atmospheric optical calibration system is provided to compare actual atmospheric optical conditions to standard atmospheric optical conditions on the basis of aerosol optical depth, relative air mass, and diffuse horizontal skylight to global horizontal photon flux ratio. An indicator can show the extent to which the actual conditions vary from standard conditions. Aerosol scattering and absorption properties, diffuse horizontal skylight to global horizontal photon flux ratio, and precipitable water vapor determined on a real-time basis for optical and pressure measurements are also used to generate a computer spectral model and for correcting actual performance response of a photovoltaic device to standard atmospheric optical condition response on a real-time basis as the device is being tested in actual outdoor conditions.

  18. Atmospheric optical calibration system

    DOEpatents

    Hulstrom, R.L.; Cannon, T.W.

    1988-10-25

    An atmospheric optical calibration system is provided to compare actual atmospheric optical conditions to standard atmospheric optical conditions on the basis of aerosol optical depth, relative air mass, and diffuse horizontal skylight to global horizontal photon flux ratio. An indicator can show the extent to which the actual conditions vary from standard conditions. Aerosol scattering and absorption properties, diffuse horizontal skylight to global horizontal photon flux ratio, and precipitable water vapor determined on a real-time basis for optical and pressure measurements are also used to generate a computer spectral model and for correcting actual performance response of a photovoltaic device to standard atmospheric optical condition response on a real-time basis as the device is being tested in actual outdoor conditions. 7 figs.

  19. Inspection system calibration methods

    DOEpatents

    Deason, Vance A.; Telschow, Kenneth L.

    2004-12-28

    An inspection system calibration method includes producing two sideband signals of a first wavefront; interfering the two sideband signals in a photorefractive material, producing an output signal therefrom having a frequency and a magnitude; and producing a phase modulated operational signal having a frequency different from the output signal frequency, a magnitude, and a phase modulation amplitude. The method includes determining a ratio of the operational signal magnitude to the output signal magnitude, determining a ratio of a 1st order Bessel function of the operational signal phase modulation amplitude to a 0th order Bessel function of the operational signal phase modulation amplitude, and comparing the magnitude ratio to the Bessel function ratio.

  20. BXS Re-calibration

    SciTech Connect

    Welch, J; /SLAC

    2010-11-24

    Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel

  1. Tracking system analytic calibration activities for the Mariner Mars 1971 mission

    NASA Technical Reports Server (NTRS)

    Madrid, G. A.; Chao, C. C.; Fliegel, H. F.; Leavitt, R. K.; Mottinger, N. A.; Winn, F. B.; Wimberly, R. N.; Yip, K. B.; Zielenbach, J. W.

    1974-01-01

    Data covering various planning aspects of Mariner Mars 1971 mission are summarized. Data cover calibrating procedures for tracking stations, radio signal propagation in the troposphere, effects of charged particles on radio transmission, orbit calculation, and data smoothing.

  2. beta-Chloronaphthalene

    Integrated Risk Information System (IRIS)

    beta - Chloronaphthalene ; CASRN 91 - 58 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcin

  3. beta-Propiolactone

    Integrated Risk Information System (IRIS)

    beta - Propiolactone ; CASRN 57 - 57 - 8 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogen

  4. Trichoderma .beta.-glucosidase

    DOEpatents

    Dunn-Coleman, Nigel; Goedegebuur, Frits; Ward, Michael; Yao, Jian

    2006-01-03

    The present invention provides a novel .beta.-glucosidase nucleic acid sequence, designated bgl3, and the corresponding BGL3 amino acid sequence. The invention also provides expression vectors and host cells comprising a nucleic acid sequence encoding BGL3, recombinant BGL3 proteins and methods for producing the same.

  5. CALIBRATION OF THERMOLUMINESCENCE AND FILM DOSEMETERS FOR SKIN DOSES FROM HIGH-ACTIVITY MICROPARTICLES.

    PubMed

    Eakins, J S; Hager, L G; Tanner, R J

    2016-09-01

    The use of EXT-RAD™ extremity TLDs and radiochromic film to measure doses from primarily beta-emitting microparticles is discussed. Specific calibration techniques have been developed, using both Monte Carlo modelling and experiments. Results for a (90)Sr/(90)Y microparticle are presented to illustrate the general techniques and to demonstrate reasonable agreement between the dosimetry methods.

  6. VizieR Online Data Catalog: Metallicity calibrations for UBV photometry (Karatas+, 2006)

    NASA Astrophysics Data System (ADS)

    Karatas, Y.; Schuster, W. J.

    2007-05-01

    UBV photometry [V, (B-V), (U-B)] has been collected from large data bases in conjunction with the derivation of intrinsic-colour, metallicity and absolute magnitude calibrations of F-, G- and early-K-type stars for uvby-beta photometry being derived by Karata & Schuster (in preparation). (2 data files).

  7. VizieR Online Data Catalog: [Fe/H] & VMAG calibrations for UBV photometry (Karatas+, 2006)

    NASA Astrophysics Data System (ADS)

    Karatas, Y.; Schuster, W. J.

    2007-05-01

    UBV photometry [V, (B-V), (U-B)] has been collected from large data bases in conjunction with the derivation of intrinsic-colour, metallicity and absolute magnitude calibrations of F-, G- and early-K-type stars for uvby-beta photometry being derived by Karata & Schuster (in preparation). (2 data files).

  8. Beta-2 Microglobulin Tumor Marker

    MedlinePlus

    ... limited. Home Visit Global Sites Search Help? Beta-2 Microglobulin Tumor Marker Share this page: Was this page helpful? Also known as: B2M; B 2 M; β2-Microglobulin; Thymotaxin Formal name: Beta 2 ...

  9. The Mars Science Laboratory APXS calibration target: Comparison of Martian measurements with the terrestrial calibration

    NASA Astrophysics Data System (ADS)

    Campbell, J. L.; King, P. L.; Burkemper, L.; Berger, J. A.; Gellert, R.; Boyd, N. I.; Perrett, G. M.; Pradler, I.; Thompson, L.; Edgett, K. S.; Yingst, R. A.

    2014-03-01

    The Mars Science Laboratory Curiosity rover carries a basalt calibration target for monitoring the performance of the alpha particle X-ray spectrometer. The spectrum acquired on Sol 34 shows increased contributions from Mg, S, Cl and Fe relative to laboratory spectra recorded before launch. Mars Hand Lens Imager images confirm changes in the appearance of the surface. Spectra taken on Sols 179 and 411 indicate some loss of the deposited material. The observations suggest deposition of a surface film likely consisting of dust mobilized by impingement of the sky crane's terminal descent engine plumes with surface fines during Curiosity's landing. New APXS software has been used to model the thin film that coated the calibration target on landing. The results suggest that a film of about 100 nm thickness, and containing predominantly MgO, Fe2O3, SO3, Cl and Na2O could give rise to the observed spectral changes. If this film is also present on the alpha particle sources within the APXS, then its effect is negligible and the terrestrial calibration remains appropriate.

  10. A new polarimetric active radar calibrator and calibration technique

    NASA Astrophysics Data System (ADS)

    Tang, Jianguo; Xu, Xiaojian

    2015-10-01

    Polarimetric active radar calibrator (PARC) is one of the most important calibrators with high radar cross section (RCS) for polarimetry measurement. In this paper, a new double-antenna polarimetric active radar calibrator (DPARC) is proposed, which consists of two rotatable antennas with wideband electromagnetic polarization filters (EMPF) to achieve lower cross-polarization for transmission and reception. With two antennas which are rotatable around the radar line of sight (LOS), the DPARC provides a variety of standard polarimetric scattering matrices (PSM) through the rotation combination of receiving and transmitting polarization, which are useful for polarimatric calibration in different applications. In addition, a technique based on Fourier analysis is proposed for calibration processing. Numerical simulation results are presented to demonstrate the superior performance of the proposed DPARC and processing technique.

  11. Screening Surface Contamination with BetaCage

    SciTech Connect

    Schnee, R. W.; Grant, D. R.; Poinar, K.; Ahmed, Z.; Golwala, S. R.

    2007-03-28

    Existing screening facilities are insufficiently sensitive to meet the needs of rare-event experiments for low-energy electron emitters and alpha-decaying isotopes. To provide such screening, the BetaCage will be a low-background, atmospheric-pressure neon drift chamber with unprecedented sensitivity to emitters of low-energy electrons and alpha particles. Minimization of the detector mass and use of radiopure materials reduce background events. The chamber design accepts nearly all alphas and low-energy electrons from the sample surface while allowing excellent rejection of residual backgrounds. A non-radiopure prototype is under construction to test the design. The BetaCage will provide new infrastructure for rare-event science as well as for a wider community that uses radioactive screening for areas including archaeology, biology, climatology, environmental science, geology, planetary science, and integrated-circuit quality control.

  12. General defocusing particle tracking.

    PubMed

    Barnkob, Rune; Kähler, Christian J; Rossi, Massimiliano

    2015-09-01

    A General Defocusing Particle Tracking (GDPT) method is proposed for tracking the three-dimensional motion of particles in Lab-on-a-chip systems based on a set of calibration images and the normalized cross-correlation function. In comparison with other single-camera defocusing particle-tracking techniques, GDPT possesses a series of key advantages: it is applicable to particle images of arbitrary shapes, it is intuitive and easy to use, it can be used without advanced knowledge of optics and velocimetry theory, it is robust against outliers and overlapping particle images, and it requires only equipment which is standard in microfluidic laboratories. We demonstrate the method by tracking the three-dimensional motion of 2 μm spherical particles in a microfluidic channel using three different optical arrangements. The position of the particles was measured with an estimated uncertainty of 0.1 μm in the in-plane direction and 2 μm in the depth direction for a measurement volume of 1510 × 1270 × 160 μm(3). A ready-to-use GUI implementation of the method can be acquired on . PMID:26201498

  13. Misleading Betas: An Educational Example

    ERIC Educational Resources Information Center

    Chong, James; Halcoussis, Dennis; Phillips, G. Michael

    2012-01-01

    The dual-beta model is a generalization of the CAPM model. In the dual-beta model, separate beta estimates are provided for up-market and down-market days. This paper uses the historical "Anscombe quartet" results which illustrated how very different datasets can produce the same regression coefficients to motivate a discussion of the…

  14. Calibration of the ARID robot

    NASA Technical Reports Server (NTRS)

    Doty, Keith L

    1992-01-01

    The author has formulated a new, general model for specifying the kinematic properties of serial manipulators. The new model kinematic parameters do not suffer discontinuities when nominally parallel adjacent axes deviate from exact parallelism. From this new theory the author develops a first-order, lumped-parameter, calibration-model for the ARID manipulator. Next, the author develops a calibration methodology for the ARID based on visual and acoustic sensing. A sensor platform, consisting of a camera and four sonars attached to the ARID end frame, performs calibration measurements. A calibration measurement consists of processing one visual frame of an accurately placed calibration image and recording four acoustic range measurements. A minimum of two measurement protocols determine the kinematics calibration-model of the ARID for a particular region: assuming the joint displacements are accurately measured, the calibration surface is planar, and the kinematic parameters do not vary rapidly in the region. No theoretical or practical limitations appear to contra-indicate the feasibility of the calibration method developed here.

  15. Cobalt source calibration

    SciTech Connect

    Rizvi, H.M.

    1999-12-03

    The data obtained from these tests determine the dose rate of the two cobalt sources in SRTC. Building 774-A houses one of these sources while the other resides in room C-067 of Building 773-A. The data from this experiment shows the following: (1) The dose rate of the No.2 cobalt source in Building 774-A measured 1.073 x 10{sup 5} rad/h (June 17, 1999). The dose rate of the Shepherd Model 109 Gamma cobalt source in Building 773-A measured 9.27 x 10{sup 5} rad/h (June 25, 1999). These rates come from placing the graduated cylinder containing the dosimeter solution in the center of the irradiation chamber. (2) Two calibration tests in the 774-A source placed the graduated cylinder with the dosimeter solution approximately 1.5 inches off center in the axial direction. This movement of the sample reduced the measured dose rate 0.92% from 1.083 x 10{sup 5} rad/h to 1.073 x 10{sup 5} rad/h. and (3) A similar test in the cobalt source in 773-A placed the graduated cylinder approximately 2.0 inches off center in the axial direction. This change in position reduced the measured dose rate by 10.34% from 1.036 x 10{sup 6} to 9.27 x 10{sup 5}. This testing used chemical dosimetry to measure the dose rate of a radioactive source. In this method, one determines the dose by the chemical change that takes place in the dosimeter. For this calibration experiment, the author used a Fricke (ferrous ammonium sulfate) dosimeter. This solution works well for dose rates to 10{sup 7} rad/h. During irradiation of the Fricke dosimeter solution the Fe{sup 2+} ions ionize to Fe{sup 3+}. When this occurs, the solution acquires a slightly darker tint (not visible to the human eye). To determine the magnitude of the change in Fe ions, one places the solution in an UV-VIS Spectrophotometer. The UV-VIS Spectrophotometer measures the absorbency of the solution. Dividing the absorbency by the total time (in minutes) of exposure yields the dose rate.

  16. Beta-delayed proton emission from 20Mg

    NASA Astrophysics Data System (ADS)

    Lund, M. V.; Andreyev, A.; Borge, M. J. G.; Cederkäll, J.; De Witte, H.; Fraile, L. M.; Fynbo, H. O. U.; Greenlees, P. T.; Harkness-Brennan, L. J.; Howard, A. M.; Huyse, M.; Jonson, B.; Judson, D. S.; Kirsebom, O. S.; Konki, J.; Kurcewicz, J.; Lazarus, I.; Lica, R.; Lindberg, S.; Madurga, M.; Marginean, N.; Marginean, R.; Marroquin, I.; Mihai, C.; Munch, M.; Nacher, E.; Negret, A.; Nilsson, T.; Page, R. D.; Pascu, S.; Perea, A.; Pucknell, V.; Rahkila, P.; Rapisarda, E.; Riisager, K.; Rotaru, F.; Sotty, C.; Stanoiu, M.; Tengblad, O.; Turturica, A.; Van Duppen, P.; Vedia, V.; Wadsworth, R.; Warr, N.

    2016-10-01

    Beta-delayed proton emission from 20 Mg has been measured at ISOLDE, CERN, with the ISOLDE Decay Station (IDS) setup including both charged-particle and gamma-ray detection capabilities. A total of 27 delayed proton branches were measured including seven so far unobserved. An updated decay scheme, including three new resonances above the proton separation energy in 20 Na and more precise resonance energies, is presented. Beta-decay feeding to two resonances above the Isobaric Analogue State (IAS) in 20 Na is observed. This may allow studies of the 4032.9(2.4)keV resonance in 19 Ne through the beta decay of 20 Mg, which is important for the astrophysically relevant reaction 15O( α, γ)19Ne . Beta-delayed protons were used to obtain a more precise value for the half-life of 20 Mg, 91.4(1.0)ms.

  17. Complementarity of Neutrinoless Double Beta Decay and Cosmology

    SciTech Connect

    Dodelson, Scott; Lykken, Joseph

    2014-03-20

    Neutrinoless double beta decay experiments constrain one combination of neutrino parameters, while cosmic surveys constrain another. This complementarity opens up an exciting range of possibilities. If neutrinos are Majorana particles, and the neutrino masses follow an inverted hierarchy, then the upcoming sets of both experiments will detect signals. The combined constraints will pin down not only the neutrino masses but also constrain one of the Majorana phases. If the hierarchy is normal, then a beta decay detection with the upcoming generation of experiments is unlikely, but cosmic surveys could constrain the sum of the masses to be relatively heavy, thereby producing a lower bound for the neutrinoless double beta decay rate, and therefore an argument for a next generation beta decay experiment. In this case as well, a combination of the phases will be constrained.

  18. Antenna Calibration and Measurement Equipment

    NASA Technical Reports Server (NTRS)

    Rochblatt, David J.; Cortes, Manuel Vazquez

    2012-01-01

    A document describes the Antenna Calibration & Measurement Equipment (ACME) system that will provide the Deep Space Network (DSN) with instrumentation enabling a trained RF engineer at each complex to perform antenna calibration measurements and to generate antenna calibration data. This data includes continuous-scan auto-bore-based data acquisition with all-sky data gathering in support of 4th order pointing model generation requirements. Other data includes antenna subreflector focus, system noise temperature and tipping curves, antenna efficiency, reports system linearity, and instrument calibration. The ACME system design is based on the on-the-fly (OTF) mapping technique and architecture. ACME has contributed to the improved RF performance of the DSN by approximately a factor of two. It improved the pointing performances of the DSN antennas and productivity of its personnel and calibration engineers.

  19. TIME CALIBRATED OSCILLOSCOPE SWEEP CIRCUIT

    DOEpatents

    Smith, V.L.; Carstensen, H.K.

    1959-11-24

    An improved time calibrated sweep circuit is presented, which extends the range of usefulness of conventional oscilloscopes as utilized for time calibrated display applications in accordance with U. S. Patent No. 2,832,002. Principal novelty resides in the provision of a pair of separate signal paths, each of which is phase and amplitude adjustable, to connect a high-frequency calibration oscillator to the output of a sawtooth generator also connected to the respective horizontal deflection plates of an oscilloscope cathode ray tube. The amplitude and phase of the calibration oscillator signals in the two signal paths are adjusted to balance out feedthrough currents capacitively coupled at high frequencies of the calibration oscillator from each horizontal deflection plate to the vertical plates of the cathode ray tube.

  20. Local hadron calibration with ATLAS

    NASA Astrophysics Data System (ADS)

    Giovannini, Paola; ATLAS Liquid Argon Calorimeter Group

    2011-04-01

    The method of Local Hadron Calibration is used in ATLAS as one of the two major calibration schemes for the reconstruction of jets and missing transverse energy. The method starts from noise suppressed clusters and corrects them for non-compensation effects and for losses due to noise threshold and dead material. Jets are reconstructed using the calibrated clusters and are then corrected for out of cone effects. The performance of the corrections applied to the calorimeter clusters is tested with detailed GEANT4 information. Results obtained with this procedure are discussed both for single pion simulations and for di-jet simulations. The calibration scheme is validated on data, by comparing the calibrated cluster energy in data with Mote Carlo simulations. Preliminary results obtained with GeV collision data are presented. The agreement between data and Monte Carlo is within 5% for the final cluster scale.

  1. Calibration of platinum resistance thermometers.

    NASA Technical Reports Server (NTRS)

    Sinclair, D. H.; Terbeek, H. G.; Malone, J. H.

    1972-01-01

    Results of five years experience in calibrating about 1000 commercial platinum resistance thermometers (PRT) are reported. These PRT were relatively small and rugged, with ice-point resistances from 200 to 5000 ohms. Calibrations normalized in terms of resistance-difference ratios (Cragoe Z function) were found to be remarkably uniform for five of six different types of PRT tested, and to agree very closely with normalized calibrations of the primary reference standard type PRT. The Z function normalization cancels residual resistances which are not temperature dependent and simplifies interpolation between calibration points when the quality of a given type of PRT has been established in terms of uniform values of the Z function. Measurements at five or six well spaced base-point temperatures with Z interpolation will suffice to calibrate a PRT accurately from 4 to 900 K.

  2. Nuclear-structure aspects of double beta decay

    SciTech Connect

    Suhonen, Jouni

    2010-11-24

    Neutrinoless double beta (0{nu}{beta}{beta}) decay of nuclei is a process that requires the neutrino to be a massive Majorana particle and thus cannot proceed in the standard model of electro-weak interactions. Recent results of the neutrino-oscillation experiments have produced accurate information on the mixing of neutrinos and their squared mass differences. The 0{nu}{beta}{beta} decay takes place in atomic nuclei where it can be observed, at least in principle, by underground neutrino experiments. The need of nuclei in observation of the 0{nu}{beta}{beta} decay bears two facets: The nucleus serves as laboratory for detection but at the same time its complicated many-nucleon structure interferes strongly with the analysis of the experimental data. The information about the weak-interaction observables, like the neutrino mass, has to be filtered from the data through the nuclear matrix elements (NMEs). Hence, exact knowledge about the NMEs is of paramount importance in the analysis of the data provided by the expensive and time-consuming underground experiments.

  3. MAJORANA Neutrinoless Double-Beta Decay DUSEL R&D

    SciTech Connect

    Wilkerson, John F.

    2009-09-04

    The Majorana research and development is addressing key issues and risks related to the collaboration's goal of undertaking a search for neutrinoless double-beta decay (0{nu}{beta}{beta}) in {sup 76}Ge using an array of hyper-pure Ge-diodes (HPGe). The observation of this decay would provide critical insight into our understanding of neutrinos, yielding definitive evidence that neutrinos are Majorana particles and providing information on the absolute mass of neutrinos. Achieving sensitivities to 0{nu}{beta}{beta} decay half-lives on the order of 10{sup 26} years requires ultra-low backgrounds in the 2039 keV region where a 0{nu}{beta}{beta} decay peak would be observed. The goal of our R&D program has been to demonstrate the feasibility of all components of Majorana and to provide an integrated evaluation framework, allowing for optimization of these components in terms of background, background suppression, and signal detection efficiency and acceptance. This report covers work carried out by Majorana collaboration members at the University of Washington as part of the overall Majorana collaboration activities. Specifically the Majorana group at the University of Washington was involved in moving forward on demonstrating technology for clean large-scale cryostats and mounting the HPGe crystals in low-mass holders. The UW activities included assistance in the procurement and assembly of an electroforming system for large size cryostats, and design and fabrication of prototype crystal mounting hardware.

  4. Diode calibration manual

    SciTech Connect

    Brunk, J.L.

    1989-09-01

    This procedure is not for the faint of heart. It is a time consuming, complex series of journeys through advanced GAMANAL and the vagueness of analyzer electronics. A knowledge of TRIX AC, DLTV, and IMP on the Octopus system and DSCOPE, PE2, and Symphony on a PC class machine is required. Be aware that the example in this document is a condensation of information that takes up four feet of shelf space. In the attempt to convert the nomenclature of the 7600 version of GAMANAL to that of the CRAY version, there will be confusion with some of the terms used. The 7600 versions relied on punched cards to a great extent where the CRAY version doesn't use them at all. In order not to introduce a new set of nomenclature, I have changed the reference from card to card image. I hope that this will cause the least impact on the vernacular and cause the least amount of confusion possible. This document is a rewritten update of an unpublished document by Bob Wikkerink in 1980. His document was the only written record of the procedures needed to calibrate the Environmental Sciences Low Level Counting Facility. This document updates and expands this information.

  5. A calibrated Franklin chimes

    NASA Astrophysics Data System (ADS)

    Gonta, Igor; Williams, Earle

    1994-05-01

    Benjamin Franklin devised a simple yet intriguing device to measure electrification in the atmosphere during conditions of foul weather. He constructed a system of bells, one of which was attached to a conductor that was suspended vertically above his house. The device is illustrated in a well-known painting of Franklin (Cohen, 1985). The elevated conductor acquired a potential due to the electric field in the atmosphere and caused a brass ball to oscillate between two bells. The purpose of this study is to extend Franklin's idea by constructing a set of 'chimes' which will operate both in fair and in foul weather conditions. In addition, a mathematical relationship will be established between the frequency of oscillation of a metallic sphere in a simplified geometry and the potential on one plate due to the electrification of the atmosphere. Thus it will be possible to calibrate the 'Franklin Chimes' and to obtain a nearly instantaneous measurement of the potential of the elevated conductor in both fair and foul weather conditions.

  6. Calibration method for radiometric and wavelength calibration of a spectrometer

    NASA Astrophysics Data System (ADS)

    Granger, Edward M.

    1998-12-01

    A new calibration target or Certified Reference Material (CRM) has been designed that uses violet, orange, green and cyan dyes ont cotton paper. This paper type was chosen because it has a relatively flat spectral response from 400 nm to 700 nm and good keeping properties. These specific dyes were chosen because the difference signal between the orange, cyan, green and purple dyes have certain characteristics that then a low the calibration of an instrument. The ratio between the difference readings is a direct function of the center wavelength of a given spectral band. Therefore, the radiometric and spectral calibration can be determined simultaneously from the physical properties of the reference materials.

  7. Beta-thalassemia.

    PubMed

    Galanello, Renzo; Origa, Raffaella

    2010-05-21

    Beta-thalassemias are a group of hereditary blood disorders characterized by anomalies in the synthesis of the beta chains of hemoglobin resulting in variable phenotypes ranging from severe anemia to clinically asymptomatic individuals. The total annual incidence of symptomatic individuals is estimated at 1 in 100,000 throughout the world and 1 in 10,000 people in the European Union. Three main forms have been described: thalassemia major, thalassemia intermedia and thalassemia minor. Individuals with thalassemia major usually present within the first two years of life with severe anemia, requiring regular red blood cell (RBC) transfusions. Findings in untreated or poorly transfused individuals with thalassemia major, as seen in some developing countries, are growth retardation, pallor, jaundice, poor musculature, hepatosplenomegaly, leg ulcers, development of masses from extramedullary hematopoiesis, and skeletal changes that result from expansion of the bone marrow. Regular transfusion therapy leads to iron overload-related complications including endocrine complication (growth retardation, failure of sexual maturation, diabetes mellitus, and insufficiency of the parathyroid, thyroid, pituitary, and less commonly, adrenal glands), dilated myocardiopathy, liver fibrosis and cirrhosis). Patients with thalassemia intermedia present later in life with moderate anemia and do not require regular transfusions. Main clinical features in these patients are hypertrophy of erythroid marrow with medullary and extramedullary hematopoiesis and its complications (osteoporosis, masses of erythropoietic tissue that primarily affect the spleen, liver, lymph nodes, chest and spine, and bone deformities and typical facial changes), gallstones, painful leg ulcers and increased predisposition to thrombosis. Thalassemia minor is clinically asymptomatic but some subjects may have moderate anemia. Beta-thalassemias are caused by point mutations or, more rarely, deletions in the beta

  8. Theoretical study of the NO beta system

    NASA Technical Reports Server (NTRS)

    Langhoff, Stephen R.; Partridge, Harry; Bauschlicher, Charles W., Jr.; Komornicki, Andrew

    1991-01-01

    A theoretical determination of the transition moment functions (TMFs) for the beta system of NO is presented. High levels of correlation treatment are required to show the changing degree of Rydberg character in the B2II with decreasing r values. The state-averaged complete-active-space self-consistent-field multireference configuration-interaction method is used for the determination. Previous lifetime measurements made with laser-induced fluorescence, varying between 2 and 0.85 microns, are discussed in terms of the calculated lifetimes for v-prime values 0-6, which vary from 2.12-1.17 microns. When larger r values are used for the transition moment function, the calculated lifetimes correlate with experimental lifetimes. The Einstein coefficients agree with experimental results, although limitations in the calibration of the spectrometer can account for systematic differences. The correlation with earlier experimental results suggests that radiative lifetimes are in the range of 1-2 microns.

  9. Mercury Continuous Emmission Monitor Calibration

    SciTech Connect

    John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

    2009-03-12

    Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma

  10. On the biodegradation of beta-peptides.

    PubMed

    Schreiber, Jürg V; Frackenpohl, Jens; Moser, Frank; Fleischmann, Thomas; Kohler, Hans-Peter E; Seebach, Dieter

    2002-05-01

    A consortium of microorganisms was established that was able to grow with the beta-tripeptide H-beta-HVal-beta-HAla-beta-HLeu-OH, with the beta-dipeptide H-beta-HAla-beta-HLeu-OH, and with the beta-amino acids H-beta-HAla-OH, H-beta-HVal-OH, and H-beta-HLeu-OH as the sole carbon and energy sources. This growth was achieved after several incubation-transfer cycles with the beta-tripeptide as the substrate. During degradation of the beta-tripeptide H-beta-HVal-beta-HAla-beta-HLeu-OH, the temporary formation of a metabolite was observed. The metabolite was identified as the beta-dipeptide H-beta-HAla-beta-HLeu-OH by nuclear magnetic resonance spectroscopy and mass spectrometry. This result indicates that in the course of the degradation of the beta-tripeptide, the N-terminal beta-HVal residue was cleaved off by a not yet known mechanism. During the subsequent degradation of the beta-dipeptide, formation of additional metabolites could not be detected. The growth-yield coefficients Y(x/s) for growth on the beta-di- and beta-tripeptide both had a value of 0.45. When a 1:1 mixture of the beta-tripeptide and the corresponding alpha-tripeptide H-Val-Ala-Leu-OH was added to the enrichment culture, the alpha-peptide was completely utilized in six days and thereafter growth of the culture stopped. This result indicates that even in beta-peptide enrichment cultures, alpha-peptides are the preferred substrates. Our experiments clearly show for the first time that beta-peptides and beta-amino acids are amenable to biodegradation and that a microbial consortium was able to utilize these compounds as sole carbon and energy sources. Furthermore, the preparation of beta-amino acids, of derivatives thereof, and of beta-di- and beta-tripeptides is described.

  11. Thermophilic Beta-Glycosidase

    NASA Technical Reports Server (NTRS)

    Grogan, Dennis W.

    1992-01-01

    Report describes identification of thermophilic Beta-glycosidase enzyme from isolate of Sulfolobus solfataricus, sulfur-metabolizing archaebacteria growing aerobically and heterotrophically to relatively high cell yields. Enzyme useful in enzymatic conversion of cellulose to D-glucose and important in recycling of biomass. Used for removal of lactose from milk products. Offers promise as model substance for elucidation of basic principles of structural stabilization of proteins.

  12. Investigation on dynamic calibration for an optical-fiber solids concentration probe in gas-solid two-phase flows.

    PubMed

    Xu, Guiling; Liang, Cai; Chen, Xiaoping; Liu, Daoyin; Xu, Pan; Shen, Liu; Zhao, Changsui

    2013-07-17

    This paper presents a review and analysis of the research that has been carried out on dynamic calibration for optical-fiber solids concentration probes. An introduction to the optical-fiber solids concentration probe was given. Different calibration methods of optical-fiber solids concentration probes reported in the literature were reviewed. In addition, a reflection-type optical-fiber solids concentration probe was uniquely calibrated at nearly full range of the solids concentration from 0 to packed bed concentration. The effects of particle properties (particle size, sphericity and color) on the calibration results were comprehensively investigated. The results show that the output voltage has a tendency to increase with the decreasing particle size, and the effect of particle color on calibration result is more predominant than that of sphericity.

  13. Investigation on Dynamic Calibration for an Optical-Fiber Solids Concentration Probe in Gas-Solid Two-Phase Flows

    PubMed Central

    Xu, Guiling; Liang, Cai; Chen, Xiaoping; Liu, Daoyin; Xu, Pan; Shen, Liu; Zhao, Changsui

    2013-01-01

    This paper presents a review and analysis of the research that has been carried out on dynamic calibration for optical-fiber solids concentration probes. An introduction to the optical-fiber solids concentration probe was given. Different calibration methods of optical-fiber solids concentration probes reported in the literature were reviewed. In addition, a reflection-type optical-fiber solids concentration probe was uniquely calibrated at nearly full range of the solids concentration from 0 to packed bed concentration. The effects of particle properties (particle size, sphericity and color) on the calibration results were comprehensively investigated. The results show that the output voltage has a tendency to increase with the decreasing particle size, and the effect of particle color on calibration result is more predominant than that of sphericity. PMID:23867745

  14. Preparation of reactive beta-dicalcium silicate

    DOEpatents

    Shen, Ming-Shing; Chen, James M.; Yang, Ralph T.

    1982-01-01

    This invention relates to the preparation of fine particles of reactive beta-dicalcium silicate by means of a solid state process which comprises firing a mixture of calcium sulfate, silica and a reducing additive selected from the group consisting of calcium sulfide, carbon, carbon monoxide, methane and hydrogen, at a temperature of about 850.degree.-1000.degree. C. A carrier gas such as nitrogen or carbon dioxide may also be added, if desired. A high concentration of sulfur dioxide is a by-product of this process.

  15. Preparation of reactive beta-dicalcium silicate

    DOEpatents

    Shen, M.S.; Chen, J.M.; Yang, R.T.

    1980-02-28

    This invention relates to the preparation of fine particles of reactive beta-dicalcium silicate by means of a solid state process which comprises firing a mixture of calcium sulfate, silica, and a reducing additive selected from the group consisting of calcium sulfide, carbon, carbon monoxide, methane, and hydrogen, at a temperature of about 850 to 1000/sup 0/C. A carrier gas such as nitrogen or carbon dioxide may also be added, if desired. A high concentration of sulfur dioxide is a by-product of this process.

  16. {beta}-decay of {sup 13}O

    SciTech Connect

    Knudsen, H.H.; Fynbo, H.O.U.; Diget, C.A.; Jeppesen, H.B.; Riisager, K.; Borge, M.J.G.; Boutami, R.; Tengblad, O.; Dendooven, P.; Eronen, T.; Huikary, J.; Jokinen, A.S.; Kankainen, A.; Moore, I.; Nieminen, A.; Penttilae, H.; Rinta-Antila, S.; Wang, Y.; Aeystoe, J.; Fox, S.

    2005-10-01

    The {beta} decay of {sup 13}O has been studied at the IGISOL facility of the Jyvaeskylae accelerator centre (Finland). By developing a low-energy isotope-separated beam of {sup 13}O and using a modern segmented charged-particle detector array an improved measurement of the delayed proton spectrum was possible. Protons with energy up to more than 12 MeV are measured and the corresponding log(ft) values extracted. A revised decay scheme is constructed. The connection to molecular states and the shell model is discussed.

  17. Mexican national pyronometer network calibration

    NASA Astrophysics Data System (ADS)

    VAldes, M.; Villarreal, L.; Estevez, H.; Riveros, D.

    2013-12-01

    In order to take advantage of the solar radiation as an alternate energy source it is necessary to evaluate the spatial and temporal availability. The Mexican National Meterological Service (SMN) has a network with 136 meteorological stations, each coupled with a pyronometer for measuring the global solar radiation. Some of these stations had not been calibrated in several years. The Mexican Department of Energy (SENER) in order to count on a reliable evaluation of the solar resource funded this project to calibrate the SMN pyrometer network and validate the data. The calibration of the 136 pyronometers by the intercomparison method recommended by the World Meterological Organization (WMO) requires lengthy observations and specific environmental conditions such as clear skies and a stable atmosphere, circumstances that determine the site and season of the calibration. The Solar Radiation Section of the Instituto de Geofísica of the Universidad Nacional Autónoma de México is a Regional Center of the WMO and is certified to carry out the calibration procedures and emit certificates. We are responsible for the recalibration of the pyronometer network of the SMN. A continuous emission solar simulator with exposed areas with 30cm diameters was acquired to reduce the calibration time and not depend on atmospheric conditions. We present the results of the calibration of 10 thermopile pyronometers and one photovoltaic cell by the intercomparison method with more than 10000 observations each and those obtained with the solar simulator.

  18. Radiometric calibration by rank minimization.

    PubMed

    Lee, Joon-Young; Matsushita, Yasuyuki; Shi, Boxin; Kweon, In So; Ikeuchi, Katsushi

    2013-01-01

    We present a robust radiometric calibration framework that capitalizes on the transform invariant low-rank structure in the various types of observations, such as sensor irradiances recorded from a static scene with different exposure times, or linear structure of irradiance color mixtures around edges. We show that various radiometric calibration problems can be treated in a principled framework that uses a rank minimization approach. This framework provides a principled way of solving radiometric calibration problems in various settings. The proposed approach is evaluated using both simulation and real-world datasets and shows superior performance to previous approaches.

  19. ASTER TIR subsystem and calibration

    NASA Technical Reports Server (NTRS)

    Ohmae, Hirokazu

    1992-01-01

    Viewgraphs are given on the purpose of TIR, major functions, characteristics and design of various components, and calibration. The major functions are to acquire image data on the earth's surface in thermal infrared wavelength band, using mercury cadmium telluride (HgCdTe) detectors; to convert the obtained image data into the digital data to meet the Common Signal Processor (CSP) interface, and output the signals; pointing function in cross-track direction to get the wide swath of 232 km; and to calibrate the whole TIR with the blackbody on orbit, then the amplifier and subsequent transmission units are calibrated electrically.

  20. The Flux Calibration of Gaia

    NASA Astrophysics Data System (ADS)

    Pancino, E.

    2016-05-01

    The Gaia mission is described, along with its scientific potential and its updated science perfomances. Although it is often described as a self-calibrated mission, Gaia still needs to tie part of its measurements to external scales (or to convert them in physical units). A detailed decription of the Gaia spectro-photometric standard stars survey is provided, along with a short description of the Gaia calibration model. The model requires a grid of approximately 200 stars, calibrated to a few percent with respect to Vega, and covering different spectral types.

  1. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Standard: Calibration and calibration verification... for Nonwaived Testing Analytic Systems § 493.1255 Standard: Calibration and calibration verification procedures. Calibration and calibration verification procedures are required to substantiate the...

  2. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Standard: Calibration and calibration verification... for Nonwaived Testing Analytic Systems § 493.1255 Standard: Calibration and calibration verification procedures. Calibration and calibration verification procedures are required to substantiate the...

  3. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Standard: Calibration and calibration verification... for Nonwaived Testing Analytic Systems § 493.1255 Standard: Calibration and calibration verification procedures. Calibration and calibration verification procedures are required to substantiate the...

  4. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Calibration and calibration verification... for Nonwaived Testing Analytic Systems § 493.1255 Standard: Calibration and calibration verification procedures. Calibration and calibration verification procedures are required to substantiate the...

  5. 42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Standard: Calibration and calibration verification... for Nonwaived Testing Analytic Systems § 493.1255 Standard: Calibration and calibration verification procedures. Calibration and calibration verification procedures are required to substantiate the...

  6. Improving integrity of on-line grammage measurement with traceable basic calibration.

    PubMed

    Kangasrääsiö, Juha

    2010-07-01

    The automatic control of grammage (basis weight) in paper and board production is based upon on-line grammage measurement. Furthermore, the automatic control of other quality variables such as moisture, ash content and coat weight, may rely on the grammage measurement. The integrity of Kr-85 based on-line grammage measurement systems was studied, by performing basic calibrations with traceably calibrated plastic reference standards. The calibrations were performed according to the EN ISO/IEC 17025 standard, which is a requirement for calibration laboratories. The observed relative measurement errors were 3.3% in the first time calibrations at the 95% confidence level. With the traceable basic calibration method, however, these errors can be reduced to under 0.5%, thus improving the integrity of on-line grammage measurements. Also a standardised algorithm, based on the experience from the performed calibrations, is proposed to ease the adjustment of the different grammage measurement systems. The calibration technique can basically be applied to all beta-radiation based grammage measurements.

  7. A low-noise beta-radiometer

    SciTech Connect

    Antonenko, G.I.; Savina, V.I.

    1995-12-01

    The two-channel detector for a low-noise (down to 0.06 sec{sup -1}) beta-radiometer for measuring the mass concentration of {sup 90}Sr in the environment after the chemical extraction of strontium by the oxalate-nitrate method was certified at the D.I. Mendeleev Institute of Metrology (certificate No. 137/93). A detector unit using two end-window self-quenching counters with thin input windows (8 {mu}m thick and 60 mm in diameter) operating as a Geiger-Mueller counter and filled with a mixture of 90% helium (atomic gas) and 10% ethanol (organic molecules) can measure the beta-activity of two substrates concurrently. It is often used to detect the beta-radiation of {sup 90}Sr. This isotope produces particles with energies ranging from 180 to 1000 keV, and the detection efficiency is 50% at a level of 0.1 Bq after measuring for 20 min with an uncertainty of 25%.

  8. Fixture For Calibrating Pressure Probe

    NASA Technical Reports Server (NTRS)

    Ashby, George C., Jr.; Vasquez, Peter; Horsley, Lewis A.; Bowman, John T.; Zumbrun, Henry N.; Eves, John W.

    1994-01-01

    Fixture in form of specially designed clamshell housing enables in situ calibration of pressure transducer mounted in body of pressure probe in wind tunnel. Includes two metal half shells machined with necks and matching cavities, when put together, define larger neck and cavity accommodating probe. Probe secured to bottom half shell by use of clamp before installing top half shell: necessary to follow sequence to protect probe during assembly. Clamshell calibration fixture attached to pressure probe in few minutes, making it possible to calibrate pressure transducer at convenient times. Calibrations performed before and after wind-tunnel runs each day, between runs in event of delays or suspected malfunctions, and essentially any other time, without having to remove probe from wind tunnel.

  9. Rotary mode system initial instrument calibration

    SciTech Connect

    Johns, B.R.

    1994-10-01

    The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files.

  10. Software For Calibration Of Polarimetric SAR Data

    NASA Technical Reports Server (NTRS)

    Van Zyl, Jakob; Zebker, Howard; Freeman, Anthony; Holt, John; Dubois, Pascale; Chapman, Bruce

    1994-01-01

    POLCAL (Polarimetric Radar Calibration) software tool intended to assist in calibration of synthetic-aperture radar (SAR) systems. In particular, calibrates Stokes-matrix-format data produced as standard product by NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). Version 4.0 of POLCAL is upgrade of version 2.0. New options include automatic absolute calibration of 89/90 data, distributed-target analysis, calibration of nearby scenes with corner reflectors, altitude or roll-angle corrections, and calibration of errors introduced by known topography. Reduces crosstalk and corrects phase calibration without use of ground calibration equipment. Written in FORTRAN 77.

  11. Practical Study of Psychrometer Calibrations

    NASA Astrophysics Data System (ADS)

    Kentved, Anders Bonde; Heinonen, Martti; Hudoklin, Domen

    2012-09-01

    Psychrometers remain the most widely used instruments for controlling the humidity in climatic test chambers, yet the calibration of these instruments is particularly challenging. Psychrometer calibrations require careful consideration of influence variables such as the fitting and cleanliness of the wick, the effect of the calibration chamber on the air flow past the sensors, on radiation incident on the sensors, and on the dissipation heat from the built-in fan (if included). In addition, uncertainty requirements for calibration of such psychrometers are typically around 1 %rh to 2 %rh, i.e., close to the best calibration and measurement uncertainties (CMCs) claimed by national metrology institutes (NMIs). As well as their role in supporting CMCs, inter-comparisons provide a good test-ground to ensure all influence variables are controlled or otherwise accounted for in the uncertainty budget. This paper presents the results of a comparison of psychrometer calibrations performed by the NMIs in Denmark, Slovenia, and Finland. The comparison was carried out under EURAMET Project No. 1033 with the aim to investigate the equivalence of psychrometer calibrations performed at the highest level and to gather practical experience to be used in similar comparisons in the future. An aspirated electro-psychrometer was used for the comparison, and calibrations were carried out in the range from 15 %rh to 93 %rh in a temperature range from 15 °C to 70 °C. While the results show good agreement at high relative humidity, significant differences at low relative humidity are reported. It is suggested that the differences are caused by a combination of psychrometer wick contamination and a difference in the wick-wetting methods used by the participant laboratories.

  12. Blackbody comparator for thermocouple calibration

    SciTech Connect

    Ojanen, M.; Hahtela, O. M.; Heinonen, M.

    2013-09-11

    MIKES is developing a measurement set-up for calibrating thermocouples in the temperature range 960 °C - 1500 °C. The calibration method is based on direct comparison of thermocouples and radiation thermometers. We have designed a graphite blackbody comparator cell, which is operated in a horizontal single-zone tube furnace. The cell includes two blackbody cavities for radiation temperature measurements. The cavities have openings on opposite sides of the cell, allowing simultaneous measurement with two radiation thermometers. The design of the comparator allows three thermocouples to be calibrated simultaneously. The thermocouples to be calibrated are inserted in thermometer wells around one of the measurement cavities. We characterize the blackbody comparator in terms of repeatability, temperature distribution and emissivity. Finally, we validate the uncertainty analysis by comparing calibration results obtained for type B and S thermocouples to the calibration results reported by Technical Research Institute of Sweden (SP), and MIKES. The agreement in the temperature range 1000 °C - 1500 °C is within 0.90 °C, the average deviation being 0.17 °C.

  13. Comparison of Air Temperature Calibrations

    NASA Astrophysics Data System (ADS)

    Heinonen, M.; Anagnostou, M.; Bartolo, J.; Bell, S.; Benyon, R.; Bergerud, R. A.; Bojkovski, J.; Böse, N.; Dinu, C.; Smorgon, D.; Flakiewicz, K.; Martin, M. J.; Nedialkov, S.; Nielsen, M. B.; Oğuz Aytekin, S.; Otych, J.; Pedersen, M.; Rujan, M.; Testa, N.; Turzó-András, E.; Vilbaste, M.; White, M.

    2014-07-01

    European national metrology institutes use calibration systems of various types for calibrating thermometers in air. These were compared to each other for the first time in a project organized by the European Association of National Metrology Institutes (EURAMET). This EURAMET P1061 comparison project had two main objectives: (1) to study the equivalence of calibrations performed by different laboratories and (2) to investigate correlations between calibration methods and achievable uncertainties. The comparison was realized using a pair of 100 platinum resistance thermometer probes connected to a digital thermometer bridge as the transfer standard. The probes had different dimensions and surface properties. The measurements covered the temperature range between and , but each laboratory chose a subrange most relevant to its scope and performed measurements at five nominal temperature points covering the subrange. To enable comparison between the laboratories, comparison reference functions were determined using weighted least-squares fitting. Various effects related to variations in heat transfer conditions were demonstrated but clear correlations to specific characteristics of calibration system were not identified. Calibrations in air and liquid agreed typically within at and . Expanded uncertainties determined by the participants ranged from to and they were shown to be realistic in most cases.

  14. Rare particles

    SciTech Connect

    Kutschera, W.

    1984-01-01

    The use of Accelerator Mass Spectrometry (AMS) to search for hypothetical particles and known particles of rare processes is discussed. The hypothetical particles considered include fractionally charged particles, anomalously heavy isotopes, and superheavy elements. The known particles produced in rare processes discussed include doubly-charged negative ions, counting neutrino-produced atoms in detectors for solar neutrino detection, and the spontaneous emission of /sup 14/C from /sup 223/Ra. 35 references. (WHK)

  15. Particle dispersing system and method for testing semiconductor manufacturing equipment

    DOEpatents

    Chandrachood, Madhavi; Ghanayem, Steve G.; Cantwell, Nancy; Rader, Daniel J.; Geller, Anthony S.

    1998-01-01

    The system and method prepare a gas stream comprising particles at a known concentration using a particle disperser for moving particles from a reservoir of particles into a stream of flowing carrier gas. The electrostatic charges on the particles entrained in the carrier gas are then neutralized or otherwise altered, and the resulting particle-laden gas stream is then diluted to provide an acceptable particle concentration. The diluted gas stream is then split into a calibration stream and the desired output stream. The particles in the calibration stream are detected to provide an indication of the actual size distribution and concentration of particles in the output stream that is supplied to a process chamber being analyzed. Particles flowing out of the process chamber within a vacuum pumping system are detected, and the output particle size distribution and concentration are compared with the particle size distribution and concentration of the calibration stream in order to determine the particle transport characteristics of a process chamber, or to determine the number of particles lodged in the process chamber as a function of manufacturing process parameters such as pressure, flowrate, temperature, process chamber geometry, particle size, particle charge, and gas composition.

  16. Nuclear Recoil Calibration of DarkSide-50

    NASA Astrophysics Data System (ADS)

    Edkins, Erin; DarkSide Collaboration

    2016-03-01

    DarkSide-50 dark matter experiment is a liquid argon time projection chamber (TPC) surrounded by a liquid scintillator active neutron veto, designed for the direct detection of Weakly Interacting Massive Particles (WIMPs). The success of such an experiment is dependent upon a detailed understanding of both the expected signal and backgrounds, achieved using radioactive calibration sources of known energies. Nuclear recoils provide a measurement of both the expected signal and the most dangerous background, as nuclear recoils from neutrons cannot be distinguished from a dark matter signal on an event-by-event basis in the TPC. In this talk, I will present the DS-50 calibration system, and analysis of the results of the calibration of DarkSide-50 to nuclear recoils using radioactive neutron sources. See also the DS-50 presentations by X. Xiang and G. Koh.

  17. Solergy (Beta Version 1)

    2009-03-30

    SOLERGY simulates the operation and power output of a user-defined solar central receiver power plant for a time period of up to one year. SOLERGY utilizes recorded or simulated weather data and plant component performance models to calculate the power flowing through each part of the solar plant. A plant control subroutine monitors these powers and determines when to operate the various plant subsystems. The original version of the code was released in May 1987,more » within SAND86-8060 and was widely distributed. The Beta Version 1 to be released in 2009, includes some relatively small modifications to the original code.« less

  18. The Auroral Particles experiment

    NASA Technical Reports Server (NTRS)

    1981-01-01

    An instrument for the detection of particles in the energy range of 0.1 ev to 80 Kev was designed, built, tested, calibrated, and flown onboard the spacecraft ATS-6. Data from this instrument generated the following research: intensive studies of the plasma in the vicinity of the spacecraft; global variations of plasmas; correlative studies using either other spacecraft or ground based measurements; and studies of spacecraft interactions with ambient plasmas including charging, local electric fields due to differential charging, and active control of spacecraft potential. Results from this research are presented.

  19. Intramedullary anchoring strength of titanium rod with mixed beta-tricalcium phosphate and fibrin adhesive.

    PubMed

    Oyake, Yuichiro; Beppu, Moroe; Ishii, Shoji; Takagi, Masayuki; Takashi, Masahisa

    2002-01-01

    Histological and biomechanical studies were conducted in Japanese white rabbits to evaluate the effect of mixed beta-tricalcium phosphate (beta-TCP) and fibrin adhesive on bone formation around a titanium rod in femoral bone marrow. The animals received injections of fibrin adhesive with beta-TCP or hydroxyapatite into the femoral bone marrow from the distal end of the femur, where a titanium rod was inserted. Group I received fibrin adhesive only, group II received fibrin adhesive and hydroxyapatite (HA), and group III received fibrin adhesive and beta-TCP. On the examination of nondecalcified specimens, group III showed cross-bridging bone formation between beta-TCP particles at week 8, this being observed earlier than in group II. On mechanical evaluation, group III showed significant differences in maximum pull-out force at week 8, and in modulus of rigidity at week 24, compared with the other groups. On the examination of decalcified specimens, chronic inflammation was clearly identified in group I at week 8, and residual beta-TCP particles were found in group III at week 24. These results suggest that the mixture given to group III filled bone defects around the rod and promoted bone formation at a relatively early stage. Inflammation and delayed absorption of beta-TCP, which appeared to be a reaction of heterologous fibrins, caused delays in bone formation promoted by beta-TCP. Nevertheless, the use of fibrin adhesive appears to be a feasible method for loading powdered beta-TCP. PMID:11819144

  20. Providing radiometric traceability for the calibration home base of DLR by PTB

    SciTech Connect

    Taubert, D. R.; Hollandt, J.; Sperfeld, P.; Pape, S.; Hoepe, A.; Hauer, K.-O.; Gege, P.; Schwarzmaier, T.; Lenhard, K.; Baumgartner, A.

    2013-05-10

    A dedicated calibration technique was applied for the calibration of the spectral radiance transfer standard (RASTA) of the German Aerospace Center (DLR) at the Physikalisch-Technische Bundesanstalt (PTB), consisting of two independent but complementing calibration procedures to provide redundancy and smallest possible calibration uncertainties. Procedure I included two calibration steps: In a first step the optical radiation source of RASTA, an FEL lamp, was calibrated in terms of its spectral irradiance E{sub {lambda}}({lambda}) in the wavelength range from 350 nm to 2400 nm using the PTB Spectral Irradiance Calibration Equipment (SPICE), while in a second step the spectral radiance factor {beta}{sub 0 Degree-Sign :45 Degree-Sign }({lambda}) of the RASTA reflection standard was calibrated in a 0 Degree-Sign :45 Degree-Sign -viewing geometry in the wavelength range from 350 nm to 1700 nm at the robot-based gonioreflectometer facility of PTB. The achieved relative standard uncertainties (k= 1) range from 0.6 % to 3.2 % and 0.1 % to 0.6 % respectively. Procedure II was completely independent from procedure I and allowed to cover the entire spectral range of RASTA from 350 nm to 2500 nm. In the second procedure, the 0 Degree-Sign :45 Degree-Sign -viewing geometry spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign }({lambda}) of RASTA was directly calibrated at the Spectral Radiance Comparator Facility (SRCF) of PTB. The relative uncertainties for this calibration procedure range from 0.8 % in the visible up to 7.5 % at 2500 nm (k= 1). In the overlapping spectral range of both calibration procedures the calculated spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign ,calc}({lambda}) from procedure I is in good agreement with the direct measurement of procedure II, i.e. well within the combined expanded uncertainties (k= 2) of both procedures.

  1. Solution structures of {beta}-amyloid{sub 10-35} and {beta}-amyloid{sub 10-35} PEG3000 aggregates.

    SciTech Connect

    Benzinger, T. L. S.; Burkoth, T. S.; Gordon, D.; Lynn, D. G.; Meredith, S. C.; Morgan, D. M.; Seifert, S.; Thiyagarajan, P.; Urban, V.

    1999-07-02

    Small angle neutron and x-ray scattering (SANS/SAXS) studies were conducted on the structure of the aggregates formed from both the truncated model peptide {beta}-Amyloid(10-35) (A{beta}{sub 10-35}) and a block copolymer {beta}-Amyloid (10-35)-PEG3000 (A{beta}{sub 10-35}-PEG) in D{sub 2}O at pHs from 3.0 to 7.0. These studies indicate that A{beta}{sub 10-35} aggregates into rod-like particles (fibril) and their radii are strongly dependent on the Pm of the solution. The fibril-fibril association in A{beta}{sub 10-35} solutions is less of pH < 5.6, but becomes larger at higher pH. A{beta}{sub 10-35}-PEG also assembles into rod-like particles whose radius is larger by about 30 {angstrom} than that for A{beta}{sub 10-35} fibril at pH 4.2, while it is about 23 {angstrom} larger at higher pH. Contrast matching SAXS/SANS experiments that eliminate the coherent scattering from PEG reveal that PEG moiety is located at the periphery of the fibril. Also, the mass per unit length of the peptide portion is similar for both A{beta}{sub 10-35} and A{beta}{sub 10-35}-PEG fibrils at pH 5.6. The mass per unit length of the rods from SANS provides key information on the packing of A{beta}{sub 10-35} peptides in the fibril.

  2. Calibration of the NASA GRC 16 In. Mass-Flow Plug

    NASA Technical Reports Server (NTRS)

    Davis, David O.; Friedlander, David J.; Saunders, J. David; Frate, Franco C.; Foster, Lancert E.

    2012-01-01

    The results of an experimental calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug (MFP) are presented and compared to a previously obtained calibration of a 15 in. Mass-Flow Plug. An ASME low-beta, long-radius nozzle was used as the calibration reference. The discharge coefficient for the ASME nozzle was obtained by numerically simulating the flow through the nozzle from the WIND-US code. The results showed agreement between the 15 in. and 16 in. MFPs for area ratios (MFP to pipe area ratio) greater than 0.6 but deviate at area ratios below this value for reasons that are not fully understood. A general uncertainty analysis was also performed and indicates that large uncertainties in the calibration are present for low MFP area ratios.

  3. Calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug

    NASA Technical Reports Server (NTRS)

    Davis, David O.; Friedlander, David J.; Saunders, J. David; Frate, Franco C.; Foster, Lancert E.

    2014-01-01

    The results of an experimental calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug (MFP) are presented and compared to a previously obtained calibration of a 15 in. Mass-Flow Plug. An ASME low-beta, long-radius nozzle was used as the calibration reference. The discharge coefficient for the ASME nozzle was obtained by numerically simulating the flow through the nozzle from the WIND-US code. The results showed agreement between the 15 and 16 in. MFPs for area ratios (MFP to pipe area ratio) greater than 0.6 but deviate at area ratios below this value for reasons that are not fully understood. A general uncertainty analysis was also performed and indicates that large uncertainties in the calibration are present for low MFP area ratios.

  4. (Depth-dose curves of the beta reference fields (147)Pm, (85)Kr and (90)Sr/(90)Y produced by the beta secondary standard BSS2.

    PubMed

    Brunzendorf, Jens

    2012-08-01

    The most common reference fields in beta dosimetry are the ISO 6980 series 1 radiation fields produced by the beta secondary standard BSS2 and its predecessor BSS. These reference fields require sealed beta radiation sources ((147)Pm, (85)Kr or (90)Sr/(90)Y) in combination with a source-specific beam-flattening filter, and are defined only at a given distance from the source. Every radiation sources shipped with the BSS2 is sold with a calibration certificate of the Physikalisch-Technische Bundesanstalt. The calibration workflow also comprises regular depth-dose measurements. This work publishes complete depth-dose curves of the series 1 sources (147)Pm, (85)Kr and (90)Sr/(90)Y in ICRU tissue up to a depth of 11 mm,when all electrons are stopped. For this purpose, the individual depth-dose curves of all BSS2 sources calibrated so far have been determined, i.e. the complete datasets of all BSS2 beta sources have been re-evaluated. It includes 191 depth-dose curves of 116 different sources comprising more than 2200 data points in total. Appropriate analytical representations of the nuclide-specific depth-dose curves are provided for the first time.

  5. Simultaneous beta and gamma spectroscopy

    DOEpatents

    Farsoni, Abdollah T.; Hamby, David M.

    2010-03-23

    A phoswich radiation detector for simultaneous spectroscopy of beta rays and gamma rays includes three scintillators with different decay time characteristics. Two of the three scintillators are used for beta detection and the third scintillator is used for gamma detection. A pulse induced by an interaction of radiation with the detector is digitally analyzed to classify the type of event as beta, gamma, or unknown. A pulse is classified as a beta event if the pulse originated from just the first scintillator alone or from just the first and the second scintillator. A pulse from just the third scintillator is recorded as gamma event. Other pulses are rejected as unknown events.

  6. Investigation of the fast ion beta limit in MST

    NASA Astrophysics Data System (ADS)

    Capecchi, William; Eilerman, Scott; Reusch, Joshua; Koliner, Jonathan; Anderson, Jay; Lin, Liang; Clark, Jerry; Liu, Deyong

    2013-10-01

    Fast ion orbits in the reversed field pinch (RFP) magnetic configuration are well ordered and have low orbit loss, even considering the stochasticity of the magnetic field generated by multiple tearing modes. Purely classical TRANSP modeling of a 1MW tangentially injected hydrogen neutral beam in MST deuterium plasmas predicts a core-localized fast ion density that can be up to 25% of the electron density and a fast ion beta of many times the local thermal beta. However, neutral particle analysis (NPA) of an NBI-driven mode (presumably driven by a fast ion pressure gradient) clearly shows transport of core-localized fast ions and a saturated fast ion density. The TRANSP modeling is presumed valid until the onset of the beam driven mode and gives an initial estimate of the volume-averaged fast ion beta in the range of 1-2% (local core value up to 10%). Distinguishing between an experimental fast ion number limit or fast ion beta limit is performed by scanning both the magnetic field strength and the NBI energy while observing conditions at the onset of the beam driven mode. Upcoming experiments will further investigate the empirical fast ion beta limit through the use of a deuterium beam into deuterium plasma which will allow for the NPA and neutron flux signals to provide a local and global fast ion beta measurement respectively. Work supported by US DoE.

  7. Space environment durability of beta cloth in LDEF thermal blankets

    NASA Technical Reports Server (NTRS)

    Linton, Roger C.; Whitaker, Ann F.; Finckenor, Miria M.

    1993-01-01

    Beta cloth performance for use on long-term space vehicles such as Space Station Freedom (S.S. Freedom) requires resistance to the degrading effects of the space environment. The major issues are retention of thermal insulating properties through maintaining optical properties, preserving mechanical integrity, and generating minimal particulates for contamination-sensitive spacecraft surfaces and payloads. The longest in-flight test of beta cloth's durability was on the Long Duration Exposure Facility (LDEF), where it was exposed to the space environment for 68 months. The LDEF contained 57 experiments which further defined the space environment and its effects on spacecraft materials. It was deployed into low-Earth orbit (LEO) in Apr. 1984 and retrieved Jan. 1990 by the space shuttle. Among the 10,000 plus material constituents and samples onboard were thermal control blankets of multilayer insulation with a beta cloth outer cover and Velcro attachments. These blankets were exposed to hard vacuum, thermal cycling, charged particles, meteoroid/debris impacts, ultraviolet (UV) radiation, and atomic oxygen (AO). Of these space environmental exposure elements, AO appears to have had the greatest effect on the beta cloth. The beta cloth analyzed in this report came from the MSFC Experiment S1005 (Transverse Flat-Plate Heat Pipe) tray oriented approximately 22 deg from the leading edge vector of the LDEF satellite. The location of the tray on LDEF and the placement of the beta cloth thermal blankets are shown. The specific space environment exposure conditions for this material are listed.

  8. S U (5 )-inspired double beta decay

    NASA Astrophysics Data System (ADS)

    Fonseca, Renato M.; Hirsch, Martin

    2015-07-01

    The short-range part of the neutrinoless double beta amplitude is generated via the exchange of exotic particles, such as charged scalars, leptoquarks and/or diquarks. In order to give a sizable contribution to the total decay rate, the masses of these exotics should be of the order of (at most) a few TeV. Here, we argue that these exotics could be the "light" (i.e., weak-scale) remnants of some B -L violating variants of S U (5 ). We show that unification of the standard model gauge couplings, consistent with proton decay limits, can be achieved in such a setup without the need to introduce supersymmetry. Since these nonminimal S U (5 )-inspired models violate B -L , they generate Majorana neutrino masses and therefore make it possible to explain neutrino oscillation data. The light colored particles of these models can potentially be observed at the LHC, and it might be possible to probe the origin of the neutrino masses with Δ L =2 violating signals. As particular realizations of this idea, we present two models, one for each of the two possible tree-level topologies of neutrinoless double beta decay.

  9. Low energy stable plasma calibration facility.

    PubMed

    Frederick-Frost, K M; Lynch, K A

    2007-07-01

    We have designed and fabricated a low energy plasma calibration facility for testing and calibration of rocket-borne charged-particle detectors and for the investigation of plasma sheath formation in an environment with ionospheric plasma energies, densities, and Debye lengths. We describe the vacuum system and associated plasma source, which was modified from a Naval Research Laboratory design [Bowles et al. Rev. Sci. Instrum. 67, 455 (1996)]. Mechanical and electrical modifications to this cylindrical microwave resonant source are outlined together with a different method of operating the magnetron that achieves a stable discharge. This facility produces unmagnetized plasmas with densities from 1x10(3)/cm(3) to 6x10(5)/cm(3), electron temperatures from 0.1 to 1.7 eV, and plasma potentials from 0.5 to 8 V depending on varying input microwave power and neutral gas flow. For the range of input microwave power explored (350-600 W), the energy density of the plasma remains constant because of an inverse relationship between density and temperature. This relationship allows a wide range of Debye lengths (0.3-8.4 cm) to be investigated, which is ideal for simulating the ionospheric plasma sheaths we explore.

  10. Improved Position Calibration for the FAUST Detector

    NASA Astrophysics Data System (ADS)

    Bakhtiari, Layla; Heilborn, Lauren; Cammarata, Paul; McIntosh, Alan; Youngs, Mike; Chapman, Matthew; Yennello, Sherry

    2013-10-01

    The Forward Array Using Silicon Technology (FAUST), is a detector array used to measure charged particles resulting from heavy-ion reactions. Studying multifragmentation in these reactions can give insight into the Equation of State of nuclear matter, which is important for understanding concepts in astrophysics such as the formation of the atomic elements, neutron star development, and supernovae behavior. In order to characterize the events more fully, the current silicon detectors will be replaced with position sensitive Dual-Axis Dual-Lateral (DADL) detectors. To maximize the use of these new detectors, a procedure to perform position and energy calibrations with the fully assembled array had to be developed. Testing of the mask will be performed in two stages: a preliminary test with a single ring of the array, followed by a comprehensive test with all rings of FAUST. The new calibration procedure, including the custom designed mask and the in-beam testing results of a single ring, will be presented. This work was supported by the DOE and NSF-REU Program.

  11. Calibration of the LLNL Imaging Proton Spectrometer

    NASA Astrophysics Data System (ADS)

    Rasmus, A. M.; Manuel, M. J.-E.; Kuranz, C. C.; Klein, S.; Belancourt, P. X.; Fein, J. R.; MacDonald, M. J.; Drake, R. P.; Hazi, A. U.; Pollock, B. B.; Park, J.; Williams, G. J.; Chen, H.

    2014-10-01

    Ultra intense short pulse lasers incident on solid targets (e.g. Au foil) produce well collimated, broadband proton beams. These proton beams can be used to characterize magnetic fields in high-energy-density systems. The Imaging Proton Spectrometer (IPS) was previously designed and built (H. Chen 2010, RSI) for use with such laser produced proton beams. The IPS has an energy range of 50 keV-40 MeV with a resolving power (E/dE) of about 250 at 0.5 MeV and 350 at 2 MeV, as well as a single spatial imaging direction. In order to better characterize the imaging capability of this diagnostic, a 3D FEA solver has been used to calculate the magnetic field of the IPS. Particle trajectories are then obtained via numerical integration to calibrate the imaging axis of the IPS. Experiments using alpha sources will be used to verify the calculated calibration. This work is funded by the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, Grant Number DE-NA0001840. Work by LLNL was performed under the auspices of U.S. DOE under Contract DE-AC52-07NA27344.

  12. Accurate Position Calibrations for Charged Fragments

    NASA Astrophysics Data System (ADS)

    Russell, Autumn; Finck, Joseph E.; Spyrou, Artemis; Thoennessen, Michael

    2009-10-01

    The Modular Neutron Array (MoNA), located at the National Superconducting Laboratory at Michigan State University, is used in conjunction with the MSU/FSU Sweeper Magnet to study the breakup of neutron-rich nuclei. Fragmentation reactions create particle-unstable nuclei near the neutron dripline which spontaneously break up by the decay of one or two neutrons with energies that reflect the nuclear structure of unbound excited and ground states. The neutrons continue forward into MoNA where their position and time of flight are recorded, and the charged fragments' position and energy are measured by an array of detectors following the Sweeper Magnet. In such experiments the identification of the fragment of interest is done through energy loss and time-of-flight measurements using plastic scintillators. The emitted angles of the fragments are determined with the use of CRDCs. The purpose of the present work was the calibration of the CRDCs in the X and Y axis (where Z is the beam axis) using specially designed masks. This calibration was also used for the correction of the signal of the plastic scintillators, which is position dependent. The results of this work are used for the determination of the ground state of the neutron-unbound ^24N.

  13. Scintillator based beta batteries

    NASA Astrophysics Data System (ADS)

    Rensing, Noa M.; Tiernan, Timothy C.; Shirwadkar, Urmila; O'Dougherty, Patrick; Freed, Sara; Hawrami, Rastgo; Squillante, Michael R.

    2013-05-01

    Some long-term, remote applications do not have access to conventional harvestable energy in the form of solar radiation (or other ambient light), wind, environmental vibration, or wave motion. Radiation Monitoring Devices, Inc. (RMD) is carrying out research to address the most challenging applications that need power for many months or years and which have undependable or no access to environmental energy. Radioisotopes are an attractive candidate for this energy source, as they can offer a very high energy density combined with a long lifetime. Both large scale nuclear power plants and radiothermal generators are based on converting nuclear energy to heat, but do not scale well to small sizes. Furthermore, thermo-mechanical power plants depend on moving parts, and RTG's suffer from low efficiency. To address the need for compact nuclear power devices, RMD is developing a novel beta battery, in which the beta emissions from a radioisotope are converted to visible light in a scintillator and then the visible light is converted to electrical power in a photodiode. By incorporating 90Sr into the scintillator SrI2 and coupling the material to a wavelength-matched solar cell, we will create a scalable, compact power source capable of supplying milliwatts to several watts of power over a period of up to 30 years. We will present the latest results of radiation damage studies and materials processing development efforts, and discuss how these factors interact to set the operating life and energy density of the device.

  14. Particle separation

    NASA Technical Reports Server (NTRS)

    Moosmuller, Hans (Inventor); Chakrabarty, Rajan K. (Inventor); Arnott, W. Patrick (Inventor)

    2011-01-01

    Embodiments of a method for selecting particles, such as based on their morphology, is disclosed. In a particular example, the particles are charged and acquire different amounts of charge, or have different charge distributions, based on their morphology. The particles are then sorted based on their flow properties. In a specific example, the particles are sorted using a differential mobility analyzer, which sorts particles, at least in part, based on their electrical mobility. Given a population of particles with similar electrical mobilities, the disclosed process can be used to sort particles based on the net charge carried by the particle, and thus, given the relationship between charge and morphology, separate the particles based on their morphology.

  15. Particle separation

    DOEpatents

    Moosmuller, Hans; Chakrabarty, Rajan K.; Arnott, W. Patrick

    2011-04-26

    Embodiments of a method for selecting particles, such as based on their morphology, is disclosed. In a particular example, the particles are charged and acquire different amounts of charge, or have different charge distributions, based on their morphology. The particles are then sorted based on their flow properties. In a specific example, the particles are sorted using a differential mobility analyzer, which sorts particles, at least in part, based on their electrical mobility. Given a population of particles with similar electrical mobilities, the disclosed process can be used to sort particles based on the net charge carried by the particle, and thus, given the relationship between charge and morphology, separate the particles based on their morphology.

  16. Using natural beta emission for detecting concealed tobacco in parcels

    NASA Astrophysics Data System (ADS)

    Myers, Jeremy; Hussein, Esam M. A.

    2007-10-01

    It is suspected that postal systems are used for the illegal shipment of tobacco products to circumvent taxation and excise payments. This paper demonstrates that beta-particle emission from the potassium-40 contained in tobacco can be used to passively detect its presence in paperboard postal parcels. The same concept can be utilized for the detection of marijuana, whose leaves are also rich in 40K. The combination of high beta activity and a low weight is a good indicator of the presence of these two contraband materials.

  17. Spectralon diffuser calibration for MERIS

    NASA Astrophysics Data System (ADS)

    Olij, Carina; Schaarsberg, Jos G.; Werij, Henri G.; Zoutman, Erik; Baudin, Gilles; Chommeloux, Beatrice; Bezy, Jean-Loup; Gourmelon, Georges

    1997-12-01

    One of the key payload instruments of ESA's ENVISAT polar platform is the medium resolution imaging spectrometer (MERIS), aiming at improved knowledge of our planet in the fields of bio-optical oceanography, and atmospheric and land surface processes. MERIS, which is built under responsibility of Aerospatiale, will monitor the solar irradiation scattered by the Earth by employing five cameras which simultaneously record data in 15 visible and near-infrared programmable spectral bands with very low degree of polarization sensitivity. The combined field-of-view of the five cameras spans a range of 68.5 degrees. Crucial for obtaining the desired high accuracy during a four-years lifetime, is the on- board calibration unit. This calibration unit contains a set of Spectralon diffusers, which were manufactured having in mind excellent in-flight stability as well as spectral and spatial uniformity. Preflight calibration of the Spectralon diffusers was carried out at TNO-TPD. This calibration includes the measurement of the bidirectional reflectance distribution function (BRDF) for applicable angles and wavelengths, i.e., while varying angle of incidence, angle of observation, observation area on the elongated diffusers, wavelength and polarization. The diffuser calibration was performed in a class 100 cleanroom. For these measurements the TPD calibration facility, which is described in detail, has been adapted, so that it now has five geometrical degrees of freedom. Detectors have been optimized to minimize stray light. Due to extensive commissioning of the calibration setup the absolute error (1 sigma) of these measurements amounts to less than 0.5%; relative errors are in the 0.3 - 0.4% range.

  18. Waveguide Calibrator for Multi-Element Probe Calibration

    NASA Technical Reports Server (NTRS)

    Sommerfeldt, Scott D.; Blotter, Jonathan D.

    2007-01-01

    A calibrator, referred to as the spider design, can be used to calibrate probes incorporating multiple acoustic sensing elements. The application is an acoustic energy density probe, although the calibrator can be used for other types of acoustic probes. The calibrator relies on the use of acoustic waveguide technology to produce the same acoustic field at each of the sensing elements. As a result, the sensing elements can be separated from each other, but still calibrated through use of the acoustic waveguides. Standard calibration techniques involve placement of an individual microphone into a small cavity with a known, uniform pressure to perform the calibration. If a cavity is manufactured with sufficient size to insert the energy density probe, it has been found that a uniform pressure field can only be created at very low frequencies, due to the size of the probe. The size of the energy density probe prevents one from having the same pressure at each microphone in a cavity, due to the wave effects. The "spider" design probe is effective in calibrating multiple microphones separated from each other. The spider design ensures that the same wave effects exist for each microphone, each with an indivdual sound path. The calibrator s speaker is mounted at one end of a 14-cm-long and 4.1-cm diameter small plane-wave tube. This length was chosen so that the first evanescent cross mode of the plane-wave tube would be attenuated by about 90 dB, thus leaving just the plane wave at the termination plane of the tube. The tube terminates with a small, acrylic plate with five holes placed symmetrically about the axis of the speaker. Four ports are included for the four microphones on the probe. The fifth port is included for the pre-calibrated reference microphone. The ports in the acrylic plate are in turn connected to the probe sensing elements via flexible PVC tubes. These five tubes are the same length, so the acoustic wave effects are the same in each tube. The

  19. Comparing two new camera calibration methods with traditional pinhole calibrations.

    PubMed

    Lin, Psang D; Sung, Chi K

    2007-03-19

    Two novel camera calibration methods are compared with traditional pinhole calibration: one new method uses an analytic geometrical version of Snell's law (denoted as the Snell model); the other uses 6x6 matrix-based paraxial ray-tracing (referred to as the paraxial model). Pinhole model uses a perspective projection approximation to give a single lumped result for the multiple optical elements in a camera system. It is mathematically simple, but suffers from accuracy limitations since it does not consider the lens system. The Snell model is mathematically the most complex but potentially has the highest levels of accuracy for the widest range of conditions. The paraxial model has the merit of offering analytical equations for calibration.

  20. Calibration of a slimehole density sonde using MCNPX

    NASA Astrophysics Data System (ADS)

    Won, Byeongho; Hwang, Seho; Shin, Jehyun; Kim, Jongman

    2014-05-01

    The density log is a well logging tool that can continuously record bulk density of the formation. This is widely applied for a variety of fields such as the petroleum exploitation, mineral exploration, and geotechnical survey and so on. The density log is normally applied to open holes. But there are frequently difficult conditions such as cased boreholes, the variation of borehole diameter, the borehole fluid salinity, and the stand-off and so on. So we need a density correction curves for the various borehole conditions. The primary calibration curve by manufacturer is used for the formation density calculation. In case of density log used for the oil industry, the calibration curves for various borehole environments are applied to the density correction, but commonly used slim-hole density logging sonde normally have a calibration curve for the variation of borehole diameter. In order to correct the various borehole environmental conditions, it is necessary to make the primary calibration curve of density sonde using numerical modeling. Numerical modeling serves as a low-cost substitute for experimental test pits. We have performed numerical modeling using the MCNP based on Monte-Carlo methods can record average behaviors of radiation particles. In this study, the work for matching the primary calibration curve of FDGS (Formation Density Gamma Sonde) for slime borehole with a 100 mCi 137 Cs gamma source was performed. On the basis of this work, correction curves in various borehole environments were produced.

  1. 21 CFR 868.6400 - Calibration gas.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Calibration gas. 868.6400 Section 868.6400 Food... DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6400 Calibration gas. (a) Identification. A calibration gas is a device consisting of a container of gas of known concentration intended to calibrate...

  2. 21 CFR 868.6400 - Calibration gas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calibration gas. 868.6400 Section 868.6400 Food... DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6400 Calibration gas. (a) Identification. A calibration gas is a device consisting of a container of gas of known concentration intended to calibrate...

  3. 21 CFR 868.6400 - Calibration gas.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Calibration gas. 868.6400 Section 868.6400 Food... DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6400 Calibration gas. (a) Identification. A calibration gas is a device consisting of a container of gas of known concentration intended to calibrate...

  4. 21 CFR 868.6400 - Calibration gas.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Calibration gas. 868.6400 Section 868.6400 Food... DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6400 Calibration gas. (a) Identification. A calibration gas is a device consisting of a container of gas of known concentration intended to calibrate...

  5. 21 CFR 868.6400 - Calibration gas.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Calibration gas. 868.6400 Section 868.6400 Food... DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6400 Calibration gas. (a) Identification. A calibration gas is a device consisting of a container of gas of known concentration intended to calibrate...

  6. Inadequacy of high K+/nigericin for calibrating BCECF. I. Estimating steady-state intracellular pH.

    PubMed

    Boyarsky, G; Hanssen, C; Clyne, L A

    1996-10-01

    Intracellular pH (pHi) was measured in single vascular smooth muscle (VSM) cells, cultured from rabbit abdominal aorta, using 2',7'-bis(carboxyethyl)-5(6)-carboxyfluorescein (BCECF) on a microscope-based fluorescence system. Three lines of evidence are presented that using nigericin along with high external K+ to calibrate intracellular BCECF produces systematic errors in pHi. 1) The intrinsic buffering power (beta int), measured using weak bases (e.g., ammonium), was 2.5 times smaller than that measured using weak acids (e.g., propionic acid). This discrepancy became small if pHi had really been approximately 0.2 lower than what was estimated using nigericin-calibrated pHi values. 2) Total cellular buffering power (beta tot) in the presence of CO2/HCO-3 was measured and found to be much smaller than could account for the beta int, together with the contribution of CO2/HCO3 (beta CO2: assumed to be an open system buffer). If the true pHi values were approximately 0.2-0.4 lower than our nigericin-calibrated values, then the sum of beta int and beta CO2 equals beta tot. 3) A null technique was utilized for bracketing steady-state pHi; estimates of steady-state pHi using this null technique were approximately 0.2 lower than the high K+/nigericin-calibrated estimates. Four other cell types were examined: rat hepatocytes, rat corticotrophs, human keratinocytes, and rabbit fibroblasts. These other cells also displayed discrepancies between null and nigericin estimates of steady-state pHi, as well as differences between buffering power assessed using weak bases and acids. Finally, one potential source for these discrepancies is described: selecting an inappropriate external K+ to use with nigericin can produce systematic errors in pHi of approximately 0.1. PMID:8897819

  7. Internal to external wavelength calibration

    NASA Astrophysics Data System (ADS)

    Sahu, Kailash C.

    1999-01-01

    The spectra of Hen 1357 (the Stingray nebula) were used to check the internal to external wavelength calibration of the STIS first order CCD modes. The radial velocity of the Stingray nebula is known to high accuracy (< 1 km/sec) and the line with of the nebular line is very narrow (< 8 km/sec for the integrated nebula). Thus the observations of the Stingray nebula are ideal to check the internal to external wavelength calibration of the first order modes. The observations were taken in G430L and G750M modes using a 52 x 0.05 arcsec slit covering the wavelength range 2900 to 5700 A and 6295 to 6867 A, respectively. The observed wavelength range includes many nebular emission lines. The wavelengths of the nebular lines derived using the pipeline internal wavelength calibration were compared with the wavelengths derived from other ground based observations. In all cases, the wavelength match between the two is of the same order as the accuracy to which the line center can be measured. These results imply that there is no significant offset between the internal and external wavelength calibrations for these modes. The HDF-S QSO observations were also used for this test both for the first order and the Echelle modes. The results of the HDF-S QSO observations further confirm the above finding for the first order modes, and imply that there is no significant offset between the internal and external wavelength calibration for the Echelle modes.

  8. Spinning disk calibration method and apparatus for laser Doppler velocimeter

    NASA Technical Reports Server (NTRS)

    Snyder, P. K. (Inventor)

    1986-01-01

    A method and apparatus for calibrating laser Doppler velocimeters having one or more intersecting beam pairs are described. These velocimeters measure fluid velocity by observing the light scattered by particles in the fluid stream. Moving fluid particulates are simulated by fine taut wires that are radially mounted on a disk that is rotated at a known velocity. The laser beam intersection locus is first aimed at the very center of the disk and then the disk is translated so that the locus is swept by the rotating wires. The radial distance traversed is precisely measured so that the velocity of the wires (pseudo particles) may be calculated.

  9. Thyroid storm during beta blockade.

    PubMed

    Strube, P J

    1984-04-01

    A thyrotoxic patient who had received beta-adrenoceptor blockers pre-operatively suffered an episode of severe heart failure immediately following thyroidectomy and required artificial ventilation of the lungs for six hours. The possible causes are discussed and the likelihood of thyroid storm unmitigated by beta adrenergic blockade suggested.

  10. Amyloid Beta Mediates Memory Formation

    ERIC Educational Resources Information Center

    Garcia-Osta, Ana; Alberini, Cristina M.

    2009-01-01

    The amyloid precursor protein (APP) undergoes sequential cleavages to generate various polypeptides, including the amyloid [beta] (1-42) peptide (A[beta][1-42]), which is believed to play a major role in amyloid plaque formation in Alzheimer's disease (AD). Here we provide evidence that, in contrast with its pathological role when accumulated,…

  11. COMPUTATIONS ON THE PERFORMANCE OF PARTICLE FILTERS AND ELECTRONIC AIR CLEANERS

    EPA Science Inventory

    The paper discusses computations on the performance of particle filters and electronic air cleaners (EACs). The collection efficiency of particle filters and ACs is calculable if certain factors can be assumed or calibrated. For fibrous particulate filters, measurement of colle...

  12. Self-calibrating multiplexer circuit

    DOEpatents

    Wahl, Chris P.

    1997-01-01

    A time domain multiplexer system with automatic determination of acceptable multiplexer output limits, error determination, or correction is comprised of a time domain multiplexer, a computer, a constant current source capable of at least three distinct current levels, and two series resistances employed for calibration and testing. A two point linear calibration curve defining acceptable multiplexer voltage limits may be defined by the computer by determining the voltage output of the multiplexer to very accurately known input signals developed from predetermined current levels across the series resistances. Drift in the multiplexer may be detected by the computer when the output voltage limits, expected during normal operation, are exceeded, or the relationship defined by the calibration curve is invalidated.

  13. Radar altimeter calibration using SLR

    NASA Astrophysics Data System (ADS)

    Klosko, Steven M.

    1994-11-01

    Clearly a calibration of the TOPEX altimeter (and future TOPEX-class altimeters) which is more accurate and better prepared to meet the demands of global sea level trend monitoring is warranted. TOPEX/Posideon (T/P) is in its second year of data acquisition. If it survives or surpasses the two to five year projected baseline, an unprecedented opportunity for monitoring global sea level trends at mm/y levels will have been lost due to insufficient accuracy in its altimeter calibration. It is therefore paramount to revisit the design of the T/P calibration experiment and implement a more direct approach which better utilizes the accuracy of SLR to perform this needed bias assessment.

  14. Radar altimeter calibration using SLR

    NASA Technical Reports Server (NTRS)

    Klosko, Steven M.

    1994-01-01

    Clearly a calibration of the TOPEX altimeter (and future TOPEX-class altimeters) which is more accurate and better prepared to meet the demands of global sea level trend monitoring is warranted. TOPEX/Posideon (T/P) is in its second year of data acquisition. If it survives or surpasses the two to five year projected baseline, an unprecedented opportunity for monitoring global sea level trends at mm/y levels will have been lost due to insufficient accuracy in its altimeter calibration. It is therefore paramount to revisit the design of the T/P calibration experiment and implement a more direct approach which better utilizes the accuracy of SLR to perform this needed bias assessment.

  15. The NRC autocollimator calibration facility

    NASA Astrophysics Data System (ADS)

    Eves, B. J.

    2013-10-01

    An autocollimator calibration facility has been developed based upon both a precision rotary table and a sine-bar. The traceability of the system is through sub-division of the circle and hence to the SI unit of angle, and does not require traceability to the definition of the metre. The rotary encoder that measures the angle of the rotary table is calibrated through circle closure techniques to a combined standard uncertainty of 0.013 arcsec at 5° intervals. The rotation of the sine-bar is measured by two interferometers, and together with the rotary encoder, enables calibration of the scale factor of an autocollimator to a combined standard uncertainty of 1.8 × 10-5.

  16. Reduced ambiguity calibration for LOFAR

    NASA Astrophysics Data System (ADS)

    Yatawatta, Sarod

    2012-07-01

    Interferometric calibration always yields non unique solutions. It is therefore essential to remove these ambiguities before the solutions could be used in any further modeling of the sky, the instrument or propagation effects such as the ionosphere. We present a method for LOFAR calibration which does not yield a unitary ambiguity, especially under ionospheric distortions. We also present exact ambiguities we get in our solutions, in closed form. Casting this as an optimization problem, we also present conditions for this approach to work. The proposed method enables us to use the solutions obtained via calibration for further modeling of instrumental and propagation effects. We provide extensive simulation results on the performance of our method. Moreover, we also give cases where due to degeneracy, this method fails to perform as expected and in such cases, we suggest exploiting diversity in time, space and frequency.

  17. Particle generator

    DOEpatents

    Hess, Wayne P.; Joly, Alan G.; Gerrity, Daniel P.; Beck, Kenneth M.; Sushko, Peter V.; Shlyuger, Alexander L.

    2005-06-28

    Energy tunable solid state sources of neutral particles are described. In a disclosed embodiment, a halogen particle source includes a solid halide sample, a photon source positioned to deliver photons to a surface of the halide, and a collimating means positioned to accept a spatially defined plume of hyperthermal halogen particles emitted from the sample surface.

  18. Calculating Capstone Depleted Uranium Aerosol Concentrations from Beta Activity Measurements

    SciTech Connect

    Szrom, Fran; Falo, Gerald A.; Parkhurst, MaryAnn; Whicker, Jeffrey J.; Alberth, David P.

    2009-03-01

    Beta activity measurements were used as surrogate measurements of uranium mass in aerosol samples collected during the field testing phase of the Capstone Depleted Uranium (DU) Aerosol Study. These aerosol samples generated by the perforation of armored combat vehicles were used to characterize the depleted uranium (DU) source term for the subsequent human health risk assessment (HHRA) of Capstone aerosols. Establishing a calibration curve between beta activity measurements and uranium mass measurements is straightforward if the uranium isotopes are in equilibrium with their immediate short-lived, beta-emitting progeny. For DU samples collected during the Capstone study, it was determined that the equilibrium between the uranium isotopes and their immediate short lived, beta-emitting progeny had been disrupted when penetrators had perforated target vehicles. Adjustments were made to account for the disrupted equilibrium and for wall losses in the aerosol samplers. Correction factors for the disrupted equilibrium ranged from 0.16 to 1, and the wall loss correction factors ranged from 1 to 1.92.

  19. Fluorometric study of the inclusion interaction of beta-cyclodextrin derivatives with tetraphenylporphyrin and its analytical application.

    PubMed

    Yang, R; Wang, K; Xiao, D; Yang, X

    2001-07-01

    The effects of native beta-cyclodextrin (beta-CD) and four kinds of alkylated beta-cyclodextrin (beta-CDs), i.e. heptakis (2,6-di-O-isobutyl-beta-cyclodextrin) (I), heptakis (2,6-di-O-octyl-beta-cyclodextrin) (II), heptakis (2,6-di-O-dodecyl-beta-cyclodextrin) (III), and heptakis (2,6-di-O-hexadecyl-beta-cyclodextrin) (IV), on the fluorescence behaviors of tetraphenylporphyrin (TPP) are investigated. An obvious fluorescence enhancement is observed from TPP by using alkylated derivatives compared to that obtained in beta-CD aqueous or in water. A 114-N fluorescence emission intensity enhancement is found for the complex with 2,6-di-O-octyl-beta-cyclodextrin relative to the free analyte. The exact stoichiometric ratios and the formation constants of the inclusion complexes have been examined by application of curve fitting method. The linear calibration plots between fluorescence intensity and TPP concentration are determined in the 1.14 x 10(-8)-5.06 x 10(-6) mol l(-1) range.

  20. Measure for Measure: Calibrating Ten Commonly Used Calibration Scores

    ERIC Educational Resources Information Center

    Schraw, Gregory; Kuch, Fred; Gutierrez, Antonio P.

    2013-01-01

    This study examined the dimensionality of 10 different calibration measures using confirmatory factor analysis (CFA). The 10 measures were representative of five interpretative families of measures used to assess monitoring accuracy based on a 2 (performance) x 2 (monitoring judgment) contingency table. We computed scores for each of the measures…

  1. NASA's Metrology and Calibration program

    NASA Technical Reports Server (NTRS)

    Kern, Frederick A.

    1991-01-01

    The success of the National Aeronautics and Space Administration's scientific and engineering projects is often based on the capability and quality of the metrology and calibration programs of its field centers and facilities. A Metrology and Calibration Working Group, having representation from each of the NASA field centers and facilities, was established to develop and implement a program to provide a centralized direction and agency wide focus. A brief history of the Group is presented. The development of the Group's operating philosophy, the long term objectives, the measurement research and development program, and review of accomplishments is discussed.

  2. SSA Sensor Calibration Best Practices

    NASA Astrophysics Data System (ADS)

    Johnson, T.

    Best practices for calibrating orbit determination sensors in general and space situational awareness (SSA) sensors in particular are presented. These practices were developed over the last ten years within AGI and most recently applied to over 70 sensors in AGI's Commercial Space Operations Center (ComSpOC) and the US Air Force Space Command (AFSPC) Space Surveillance Network (SSN) to evaluate and configure new sensors and perform on-going system calibration. They are generally applicable to any SSA sensor and leverage some unique capabilities of an SSA estimation approach using an optimal sequential filter and smoother. Real world results are presented and analyzed.

  3. Mariner 9 television calibration - Revisited

    NASA Technical Reports Server (NTRS)

    Herkenhoff, Ken E.; Soderblom, Laurence A.; Murray, Bruce C.; Danielson, G. Edward

    1988-01-01

    Mariner 9 TV data from the 1971-1972 encounter with Mars, which contain good synoptic coverage of of the planet as well as the highest-resolution images thus far obtained for the south polar region, can lead to more accurate photometric analysis if subjected to improved processing methods. While calibration errors are rather greater than those of the Viking Orbiter cameras, both calibration data and processing software applicable to an improvement program have become available through the USGS's Planetary Image Cartography System.

  4. Method for calibrating mass spectrometers

    DOEpatents

    Anderson, Gordon A [Benton City, WA; Brands, Michael D [Richland, WA; Bruce, James E [Schwenksville, PA; Pasa-Tolic, Ljiljana [Richland, WA; Smith, Richard D [Richland, WA

    2002-12-24

    A method whereby a mass spectra generated by a mass spectrometer is calibrated by shifting the parameters used by the spectrometer to assign masses to the spectra in a manner which reconciles the signal of ions within the spectra having equal mass but differing charge states, or by reconciling ions having known differences in mass to relative values consistent with those known differences. In this manner, the mass spectrometer is calibrated without the need for standards while allowing the generation of a highly accurate mass spectra by the instrument.

  5. Image based autodocking without calibration

    SciTech Connect

    Sutanto, H.; Sharma, R.; Varma, V.

    1997-03-01

    The calibration requirements for visual servoing can make it difficult to apply in many real-world situations. One approach to image-based visual servoing without calibration is to dynamically estimate the image Jacobian and use it as the basis for control. However, with the normal motion of a robot toward the goal, the estimation of the image Jacobian deteriorates over time. The authors propose the use of additional exploratory motion to considerably improve the estimation of the image Jacobian. They study the role of such exploratory motion in a visual servoing task. Simulations and experiments with a 6-DOF robot are used to verify the practical feasibility of the approach.

  6. [Serum beta 2 microglobulin (beta 2M) following renal transplantation].

    PubMed

    Pacheco-Silva, A; Nishida, S K; Silva, M S; Ramos, O L; Azjen, H; Pereira, A B

    1994-01-01

    Although there was an important improvement in graft and patient survival the last 10 years, graft rejection continues to be a major barrier to the success of renal transplantation. Identification of a laboratory test that could help to diagnose graft rejection would facilitate the management of renal transplanted patients. PURPOSE--To evaluate the utility of monitoring serum beta 2M in recently transplanted patients. METHODS--We daily determined serum beta 2M levels in 20 receptors of renal grafts (10 from living related and 10 from cadaveric donors) and compared them to their clinical and laboratory evolution. RESULTS--Eight patients who presented immediate good renal function following grafting and did not have rejection had a mean serum beta 2M of 3.7 mg/L on the 4th day post transplant. The sensitivity of the test for the diagnosis of acute rejection was 87.5%, but the specificity was only 46%. Patients who presented acute tubular necrosis (ATN) without rejection had a progressive decrease in their serum levels of beta 2M, while their serum creatinine changed as they were dialyzed. In contrast, patients with ATN and concomitance of acute rejection or CSA nephrotoxicity presented elevated beta 2M and creatinine serum levels. CONCLUSION--Daily monitoring of serum beta 2M does not improve the ability to diagnose acute rejection in patients with good renal function. However, serum beta 2M levels seemed to be useful in diagnosing acute rejection or CSA nephrotoxicity in patients with ATN.

  7. Novel highly biodegradable biphasic tricalcium phosphates composed of alpha-tricalcium phosphate and beta-tricalcium phosphate.

    PubMed

    Li, Yanbao; Weng, Wenjian; Tam, Kim Chiu

    2007-03-01

    Novel biodegradable biphasic tricalcium phosphates (BTCP) composed of alpha-tricalcium phosphate (alpha-TCP) and beta-tricalcium phosphate (beta-TCP) were successfully synthesized by heating amorphous calcium phosphate precursors with different structures at 800 degrees C for 3 h. The ratio of alpha-TCP and beta-TCP in the calcium phosphate particle can be controlled by aging time and pH value during synthesis of the amorphous precursor.

  8. Beta Decay of 101Sn

    SciTech Connect

    Kavatsyuk, O.; Mazzocchi, C.; Janas, Z.; Banu, A.; Batist, L.; Becker, F.; Blazhev, A.; Bruchle, W.; Doring, J.; Faestermann, T.; Gorska, M.; Grawe, H.; Jungclaus, A.; Karny, M.; Kavatsyuk, M.; Klepper, O.; Kirchner, R.; La Commara, M.; Miernik, K.; Mukha, I.; Plettner, C.; Plochocki, A.; Roeckl, E.; Romoli, M.; Rykaczewski, Krzysztof Piotr; Schadel, M.; Schmidt, K.; Schwengner, R.; Zylicz, J.

    2007-01-01

    The {beta} decay of the very neutron-deficient isotope 101Sn was studied at the GSI on-line mass separator using silicon detectors for recording charged particles and germanium detectors for {gamma}-ray spectroscopy. Based on the {beta}-delayed proton data the production cross-section of 101Sn in the 50Cr + 58Ni fusion-evaporation reaction was determined to be about 60nb. The half-life of 101Sn was measured to be 1.9(3)s. For the first time {beta}-delayed {gamma}-rays of 101Sn were tentatively identified, yielding weak evidence for a cascade of 352 and 1065keV transitions in 101In. The results for the 101Sn decay as well as those from previous work on the 103Sn decay are discussed by comparing them to predictions obtained from shell model calculations employing a new interaction in the 88Sr to 132Sn model space.

  9. High Temperature Stability of Potassium Beta Alumina

    NASA Technical Reports Server (NTRS)

    Williams, R. M.; Kisor, A.; Ryan, M. A.

    1996-01-01

    None. From Objectives section: Evaluate the stability of potassium beta alumina under potassium AMTEC operating conditions. Evaluate the stability regime in which potassium beta alumina can be fabricated.

  10. The plastic scintillator detector calibration circuit for DAMPE

    NASA Astrophysics Data System (ADS)

    Yang, Haibo; Kong, Jie; Zhao, Hongyun; Su, Hong

    2016-07-01

    The Dark Matter Particle Explorer (DAMPE) is being constructed as a scientific satellite to observe high energy cosmic rays in space. Plastic scintillator detector array (PSD), developed by Institute of Modern Physics, Chinese Academy of Sciences (IMPCAS), is one of the most important parts in the payload of DAMPE which is mainly used for the study of dark matter. As an anti-coincidence detector, and a charged-particle identification detector, the PSD has a total of 360 electronic readout channels, which are distributed at four sides of PSD using four identical front end electronics (FEE). Each FEE reads out 90 charge signals output by the detector. A special calibration circuit is designed in FEE. FPGA is used for on-line control, enabling the calibration circuit to generate the pulse signal with known charge. The generated signal is then sent to the FEE for calibration and self-test. This circuit mainly consists of DAC, operation amplifier, analog switch, capacitance and resistance. By using controllable step pulse, the charge can be coupled to the charge measuring chip using the small capacitance. In order to fulfill the system's objective of large dynamic range, the FEE is required to have good linearity. Thus, the charge-controllable signal is needed to do sweep test on all channels in order to obtain the non-linear parameters for off-line correction. On the other hand, the FEE will run on the satellite for three years. The changes of the operational environment and the aging of devices will lead to parameter variation of the FEE, highlighting the need for regular calibration. The calibration signal generation circuit also has a compact structure and the ability to work normally, with the PSD system's voltage resolution being higher than 0.6%.

  11. Ultrasonic Calibration Wire Test Phantom

    SciTech Connect

    Lehman, S K; Fisher, K A; Werve, M; Chambers, D H

    2004-09-24

    We designed and built a phantom consisting of vertical wires maintained under tension to be used as an ultrasonic test, calibration, and reconstruction object for the Lawrence Livermore National Laboratory annular array scanner. We provide a description of the phantom, present example data sets, preliminary reconstructions, example metadata, and MATLAB codes to read the data.

  12. Calibration technique for electromagnetic flowmeters

    NASA Technical Reports Server (NTRS)

    Sawochka, S. G.

    1967-01-01

    Thermal calorimetric method is used to calibrate electromagnetic flowmeters for liquid alkali metals. The electromagnetic flowmeter is placed in the liquid metal flow system in series with a thermal calorimeter. Therefore, the calculated flow rate through the calorimeter can be compared directly with the respective electromagnetic flowmeter reading.

  13. Dynamic calibration of turbine flowmeters

    NASA Technical Reports Server (NTRS)

    Stevens, G. H.

    1969-01-01

    Turbine flowmeters are calibrated dynamically by means of frequency response tests, provided small perturbations are used. The indicated flow is related to the actual flow by a first order lag function. This lag function is completely defined by the breakpoint frequency which is directly proportional to mean flow rate.

  14. Beta decay and other processes in strong electromagnetic fields

    SciTech Connect

    Akhmedov, E. Kh.

    2011-09-15

    We consider effects of the fields of strong electromagnetic waves on various characteristics of quantum processes. After a qualitative discussion of the effects of external fields on the energy spectra and angular distributions of the final-state particles as well as on the total probabilities of the processes (such as decay rates and total cross sections), we present a simple method of calculating the total probabilities of processes with production of nonrelativistic charged particles. Using nuclear {beta} decay as an example, we study the weak- and strong-field limits, as well as the field-induced {beta} decay of nuclei stable in the absence of the external fields, both in the tunneling and multiphoton regimes. We also consider the possibility of accelerating forbidden nuclear {beta} decays by lifting the forbiddeness due to the interaction of the parent or daughter nuclei with the field of a strong electromagnetic wave. It is shown that for currently attainable electromagnetic fields all effects on total {beta}-decay rates are unobservably small.

  15. Inducible beta-oxidation pathway in Neurospora crassa.

    PubMed Central

    Kionka, C; Kunau, W H

    1985-01-01

    An inducible beta-oxidation system was demonstrated in a particulate fraction from Neurospora crassa. The activities of all individual beta-oxidation enzymes were enhanced in cells after a shift from a sucrose to an acetate medium. The induction was even more pronounced in transfer to a medium containing oleate as sole carbon and energy source. Since an acyl-coenzyme A (CoA) dehydrogenase was detected instead of acyl-CoA oxidase, the former enzyme seems to catalyze the first step of the beta-oxidation sequence in N. crassa. After isopycnic centrifugation in a linear sucrose gradient, the intracellular organelles housing the fatty acid degradation pathway cosedimented (1.21 g/cm3) with the glyoxylate bypass enzymes isocitrate lyase and malate synthase and were clearly resolved from both mitochondrial marker enzymes (1.19 g/cm3) and catalase (1.26 g/cm3). On the basis of biochemical as well as morphological properties, these particles from N. crassa have recently been designated as glyoxysome-like particles (G. Wanner and T. Theimer, Ann. N.Y. Acad. Sci. 386:269-284, 1982). The failure to detect catalase, urate oxidase, and acyl-CoA oxidase indicate that these glyoxysome-like microbodies in N. crassa lack peroxisomal function and thus are clearly different from the various microbodies reported so far to contain a beta-oxidation pathway. PMID:3155714

  16. Variants of beta-glucosidases

    SciTech Connect

    Fidantsef, Ana; Lamsa, Michael; Gorre-Clancy, Brian

    2014-10-07

    The present invention relates to variants of a parent beta-glucosidase, comprising a substitution at one or more positions corresponding to positions 142, 183, 266, and 703 of amino acids 1 to 842 of SEQ ID NO: 2 or corresponding to positions 142, 183, 266, and 705 of amino acids 1 to 844 of SEQ ID NO: 70, wherein the variant has beta-glucosidase activity. The present invention also relates to nucleotide sequences encoding the variant beta-glucosidases and to nucleic acid constructs, vectors, and host cells comprising the nucleotide sequences.

  17. Variants of beta-glucosidase

    SciTech Connect

    Fidantsef, Ana; Lamsa, Michael; Gorre-Clancy, Brian

    2015-07-14

    The present invention relates to variants of a parent beta-glucosidase, comprising a substitution at one or more positions corresponding to positions 142, 183, 266, and 703 of amino acids 1 to 842 of SEQ ID NO: 2 or corresponding to positions 142, 183, 266, and 705 of amino acids 1 to 844 of SEQ ID NO: 70, wherein the variant has beta-glucosidase activity. The present invention also relates to nucleotide sequences encoding the variant beta-glucosidases and to nucleic acid constructs, vectors, and host cells comprising the nucleotide sequences.

  18. Variants of beta-glucosidase

    SciTech Connect

    Fidantsef, Ana; Lamsa, Michael; Gorre-Clancy, Brian

    2009-12-29

    The present invention relates to variants of a parent beta-glucosidase, comprising a substitution at one or more positions corresponding to positions 142, 183, 266, and 703 of amino acids 1 to 842 of SEQ ID NO: 2 or corresponding to positions 142, 183, 266, and 705 of amino acids 1 to 844 of SEQ ID NO: 70, wherein the variant has beta-glucosidase activity. The present invention also relates to nucleotide sequences encoding the variant beta-glucosidases and to nucleic acid constructs, vectors, and host cells comprising the nucleotide sequences.

  19. Variants of beta-glucosidases

    DOEpatents

    Fidantsef, Ana; Lamsa, Michael; Clancy, Brian Gorre

    2008-08-19

    The present invention relates to variants of a parent beta-glucosidase, comprising a substitution at one or more positions corresponding to positions 142, 183, 266, and 703 of amino acids 1 to 842 of SEQ ID NO: 2 or corresponding to positions 142, 183, 266, and 705 of amino acids 1 to 844 of SEQ ID NO: 70, wherein the variant has beta-glucosidase activity. The present invention also relates to nucleotide sequences encoding the variant beta-glucosidases and to nucleic acid constructs, vectors, and host cells comprising the nucleotide sequences.

  20. Capturing relic neutrinos with {beta}- and double {beta}-decaying nuclei

    SciTech Connect

    Hodak, Rastislav; Kovalenko, Sergey; Simkovic, Fedor

    2009-11-09

    Neutrinos are probably one of the most important structural constituents of the Universe. The Big Bang Theory predicts that the significant component of them is formed by the cosmic neutrino background, an analogues of the big bang relic photons comprising the cosmic microwave background radiation, which has been measured with amazing accuracy. Properties of the relic neutrino background are closely related to the ones of the cosmic microwave radiation. Relic neutrinos pervade space, but their temperature is extremely small, being of the order of 0.1 meV. Although belonging to the most abundant particles of the Universe, the relic neutrinos evade direct detection so far. This is because the low-energy neutrinos interact only very weakly with matter. In this contribution, we explore the feasibility to detect the cosmic neutrino background by means of {beta}-decaying ({sup 3}H and {sup 187}Re) and double beta decaying ({sup 100}Mo) nuclei. In addition, we address the question whether double relic neutrino capture on nuclei can be an obstacle for observation of neutrinoless double {beta}-decay.

  1. The Application of Global Kinetic Models to HMX Beta-Delta Transition and Cookoff Processes

    SciTech Connect

    Wemhoff, A P; Burnham, A K; Nichols III, A L

    2006-12-07

    The reduction of the number of reactions in kinetic models for both the HMX beta-delta phase transition and thermal cookoff provides an attractive alternative to traditional multi-stage kinetic models due to reduced calibration effort requirements. In this study, we use the LLNL code ALE3D to provide calibrated kinetic parameters for a two-reaction bidirectional beta-delta HMX phase transition model based on Sandia Instrumented Thermal Ignition (SITI) and Scaled Thermal Explosion (STEX) temperature history curves, and a Prout-Tompkins cookoff model based on One-Dimensional Time to Explosion (ODTX) data. Results show that the two-reaction bidirectional beta-delta transition model presented here agrees as well with STEX and SITI temperature history curves as a reversible four-reaction Arrhenius model, yet requires an order of magnitude less computational effort. In addition, a single-reaction Prout-Tompkins model calibrated to ODTX data provides better agreement with ODTX data than a traditional multi-step Arrhenius model, and can contain up to 90% less chemistry-limited time steps for low-temperature ODTX simulations. Manual calibration methods for the Prout-Tompkins kinetics provide much better agreement with ODTX experimental data than parameters derived from Differential Scanning Calorimetry (DSC) measurements at atmospheric pressure. The predicted surface temperature at explosion for STEX cookoff simulations is a weak function of the cookoff model used, and a reduction of up to 15% of chemistry-limited time steps can be achieved by neglecting the beta-delta transition for this type of simulation. Finally, the inclusion of the beta-delta transition model in the overall kinetics model can affect the predicted time to explosion by 1% for the traditional multi-step Arrhenius approach, while up to 11% using a Prout-Tompkins cookoff model.

  2. Observation of finite-. beta. MHD phenomena in tokamaks

    SciTech Connect

    McGuire, K.M.

    1984-09-01

    Stable high-beta plasmas are required for the tokamak to attain an economical fusion reactor. Recently, intense neutral beam heating experiments in tokamaks have shown new effects on plasma stability and confinement associated with high beta plasmas. The observed spectrum of MHD fluctuations at high beta is clearly dominated by the n = 1 mode when the q = 1 surface is in the plasma. The m/n = 1/1 mode drives other n = 1 modes through toroidal coupling and n > 1 modes through nonlinear coupling. On PDX, with near perpendicular injection, a resonant interaction between the n = 1 internal kink and the trapped fast ions results in loss of beam particles and heating power. Key parameters in the theory are the value of q/sub 0/ and the injection angle. High frequency broadband magnetic fluctuations have been observed on ISX-B and D-III and a correlation with the deterioration of plasma confinement was reported. During enhanced confinement (H-mode) discharges in divertor plasmas, two new edge instabilities were observed, both localized radially near the separatrix. By assembling results from the different tokamak experiments, it is found that the simple theoretical ideal MHD beta limit has not been exceeded. Whether this represents an ultimate tokamak limit or if beta optimized configurations (Dee- or bean-shaped plasmas) can exceed this limit and perhaps enter a second regime of stability remains to be clarified.

  3. Particle therapy

    SciTech Connect

    Raju, M.R.

    1993-09-01

    Particle therapy has a long history. The experimentation with particles for their therapeutic application got started soon after they were produced in the laboratory. Physicists played a major role in proposing the potential applications in radiotherapy as well as in the development of particle therapy. A brief review of the current status of particle radiotherapy with some historical perspective is presented and specific contributions made by physicists will be pointed out wherever appropriate. The rationale of using particles in cancer treatment is to reduce the treatment volume to the target volume by using precise dose distributions in three dimensions by using particles such as protons and to improve the differential effects on tumors compared to normal tissues by using high-LET radiations such as neutrons. Pions and heavy ions combine the above two characteristics.

  4. Particle astrophysics

    NASA Technical Reports Server (NTRS)

    Sadoulet, Bernard; Cronin, James; Aprile, Elena; Barish, Barry C.; Beier, Eugene W.; Brandenberger, Robert; Cabrera, Blas; Caldwell, David; Cassiday, George; Cline, David B.

    1991-01-01

    The following scientific areas are reviewed: (1) cosmology and particle physics (particle physics and the early universe, dark matter, and other relics); (2) stellar physics and particles (solar neutrinos, supernovae, and unconventional particle physics); (3) high energy gamma ray and neutrino astronomy; (4) cosmic rays (space and ground observations). Highest scientific priorities for the next decade include implementation of the current program, new initiatives, and longer-term programs. Essential technological developments, such as cryogenic detectors of particles, new solar neutrino techniques, and new extensive air shower detectors, are discussed. Also a certain number of institutional issues (the funding of particle astrophysics, recommended funding mechanisms, recommended facilities, international collaborations, and education and technology) which will become critical in the coming decade are presented.

  5. NEW CALIBRATION OF THE MICROMETEOROID FLUX ON EARTH

    SciTech Connect

    Cremonese, G.; Borin, P.; Martellato, E.; Marzari, F.; Bruno, M.

    2012-04-20

    Mass accretion rate on Earth is an important tool to discriminate the extraterrestrial nature of particles or isotopes found in different environments on the ground. In this context, the knowledge of the micrometeoroid flux arriving in our atmosphere is a key parameter and it needs to be calibrated. We provide a new calibration of the flux of submillimeter particles impacting the Earth in the mass range from 10{sup -9} to 10{sup -4} g, derived by computing a specific scaling law for impact craters on the Long Duration Exposure Facility (LDEF). We use the hydrocode iSALE to calculate the outcome of impacts on LDEF, adopting realistic impact velocities for dust particles derived from the numerical integration of their trajectories assuming either asteroidal or cometary origin. We estimate a particle mass accretion rate of (7.4 {+-} 1.0) Multiplication-Sign 10{sup 6} kg yr{sup -1} if the Main Belt is assumed as the major source of dust, while it reduces to (4.2 {+-} 0.5) Multiplication-Sign 10{sup 6} kg yr{sup -1} if cometary dust dominates. These values agree with the estimates provided by independent measurements made on ice core and ocean sediments and based on the abundance of some elements in the samples.

  6. Predicting Reactor Antineutrino Emissions Using New Precision Beta Spectroscopy

    SciTech Connect

    Asner, David M.; Burns, Kimberly A.; Greenfield, Bryce A.; Kos, Marek S.; Orrell, John L.; Schram, Malachi; VanDevender, Brent A.; Wootan, David W.

    2013-05-01

    Neutrino experiments at nuclear reactors are currently vital to the study of neutrino oscillations. The observed antineutrino rates at reactors are typically lower than model expectations. This observed deficit is called the “reactor neutrino anomaly”. A new understanding of neutrino physics may be required to explain this deficit, though model estimation uncertainties may also play a role in the apparent discrepancy. PNNL is currently investigating an experimental technique that promises reduced uncertainties for measured data to support these hypotheses and interpret reactor antineutrino measurements. The experimental approach is to 1) direct a proton accelerator beam on a metal target to produce a source of neutrons, 2) use spectral tailoring to modify the neutron spectrum to closely simulate the energy distribution of a power reactor neutron spectrum, 3) irradiate isotopic fission foils (235U, 238U, 239Pu, 241Pu) in this neutron spectrum so that fissions occur at energies representative of a reactor, 4) transport the beta particles released by the fission products in the foils to a beta spectrometer, 5) measure the beta energy spectrum, and 6) invert the measured beta energy spectrum to an antineutrino energy spectrum. A similar technique using a beta spectrometer and isotopic fission foils was pioneered in the 1980’s at the ILL thermal reactor. Those measurements have been the basis for interpreting all subsequent antineutrino measurements at reactors. A basic constraint in efforts to reduce uncertainties in predicting the antineutrino emission from reactor cores is any underlying limitation of the original measurements. This may include beta spectrum energy resolution, the absolute normalization of beta emission to number of fission, statistical counting uncertainties, lack of 238U data, the purely thermal nature of the IIL reactor neutrons used, etc. An accelerator-based neutron source that can be tailored to match various reactor neutron spectra

  7. A precise in situ calibration of the RHIC H-Jet polarimeter

    SciTech Connect

    Poblaguev, A. A.

    2014-03-05

    Two new methods of calibration of the hydrogen jet target polarimeter (H-Jet) at RHIC are discussed. First method is based on the measurement of low amplitude signal time of fast particles penetrating through detector. The second, geometry based, method employs correlation between z-coordinate of the recoil proton and its kinetic energy. Both methods can be used for in situ calibration of the H-Jet polarimeter. These two methods are compared with a traditional calibration of the H-Jet which uses α-sources.

  8. A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Kanematsu, Nobuyuki; Matsufuji, Naruhiro; Kohno, Ryosuke; Minohara, Shinichi; Kanai, Tatsuaki

    2003-04-01

    A method to establish the relationship between CT number and effective density for therapeutic radiations is proposed. We approximated body tissues to mixtures of muscle, air, fat and bone. Consequently, the relationship can be calibrated only with a CT scan of their substitutes, for which we chose water, air, ethanol and potassium phosphate solution, respectively. With simple and specific corrections for non-equivalencies of the substitutes, a calibration accuracy of 1% will be achieved. We tested the calibration method with some biological materials to verify that the proposed method would offer the accuracy, simplicity and specificity required for a standard in radiotherapy treatment planning, in particular with heavy charged particles.

  9. GIADA - Grain Impact Analyzer and Dust Accumulator - Onboard Rosetta spacecraft: Extended calibrations

    NASA Astrophysics Data System (ADS)

    Della Corte, V.; Sordini, R.; Accolla, M.; Ferrari, M.; Ivanovski, S.; Rotundi, A.; Rietmeijer, F. J. M.; Fulle, M.; Mazzotta-Epifani, E.; Palumbo, P.; Colangeli, L.; Lopez-Moreno, J. J.; Rodriguez, J.; Morales, R.; Cosi, M.

    2016-09-01

    Despite a long tradition of dust instruments flown on-board space mission, the largest number of these can be considered unique as they used different detection techniques. GIADA (Grain Impact Analyzer and Dust Accumulator), is one of the dust instruments on-board the Rosetta spacecraft and is devoted to measure the dust dynamical parameters in the coma of comet 67P/Churyumov-Gerasimenko. It couples two different techniques to measure the mass and speed of individual dust particles. We report here the results of an extended calibration activity carried-out, during the hibernation phase of the Rosetta mission, on the GIADA Proto Flight Model (PFM) operative in a clean room in our laboratory. The main aims of an additional calibration campaign are: to verify the algorithms and procedures for data calibration developed before Rosetta launch; to improve the comprehension of GIADA response after the increased knowledge on cometary dust, e.g. the composition of dust particles after Stardust mission. These calibration improvements implied a final step, which consisted in defining transfer functions to correlate the new calibration curves obtained for the GIADA PFM to those to be used for GIADA onboard the Rosetta spacecraft. The extended calibration activity allowed us to analyze GIADA data acquired in the 67P/C-G coma permitting to infer additional information on cometary dust particles, e.g. density and tensile strength.

  10. Turbulence structure of finite-beta perpendicular fast shocks

    NASA Technical Reports Server (NTRS)

    Coroniti, F. V.

    1970-01-01

    In a finite-beta plasma ion cyclotron, radius dispersion which forms a trailing wave train for a perpendicular fast shock is examined. Collisionless dissipation is provided by the three wave decay of the wave train into very oblique fast and parallel Alfven waves. Particle thermalization results from Landau damping of oblique fast wave turbulence. The shock damping length to three wave decay is many ion cyclotron radii. Undamped Alfven turbulence should persist far downstream from the shock.

  11. Magnetic particles

    NASA Technical Reports Server (NTRS)

    Chang, Manchium (Inventor); Colvin, Michael S. (Inventor)

    1989-01-01

    Magnetic polymer particles are formed by swelling porous, polymer particles and impregnating the particles with an aqueous solution of precursor magnetic metal salt such as an equimolar mixture of ferrous chloride and ferric chloride. On addition of a basic reagent such as dilute sodium hydroxide, the metal salts are converted to crystals of magnetite which are uniformly contained througout the pores of the polymer particle. The magnetite content can be increased and neutral buoyancy achieved by repetition of the impregnaton and neutralization steps to adjust the magnetite content to a desired level.

  12. Extracting the MESA SR4000 calibrations

    NASA Astrophysics Data System (ADS)

    Charleston, Sean A.; Dorrington, Adrian A.; Streeter, Lee; Cree, Michael J.

    2015-05-01

    Time-of-flight range imaging cameras are capable of acquiring depth images of a scene. Some algorithms require these cameras to be run in `raw mode', where any calibrations from the off-the-shelf manufacturers are lost. The calibration of the MESA SR4000 is herein investigated, with an attempt to reconstruct the full calibration. Possession of the factory calibration enables calibrated data to be acquired and manipulated even in "raw mode." This work is motivated by the problem of motion correction, in which the calibration must be separated into component parts to be applied at different stages in the algorithm. There are also other applications, in which multiple frequencies are required, such as multipath interference correction. The other frequencies can be calibrated in a similar way, using the factory calibration as a base. A novel technique for capturing the calibration data is described; a retro-reflector is used on a moving platform, which acts as a point source at a distance, resulting in planar waves on the sensor. A number of calibrations are retrieved from the camera, and are then modelled and compared to the factory calibration. When comparing the factory calibration to both the "raw mode" data, and the calibration described herein, a root mean squared error improvement of 51:3mm was seen, with a standard deviation improvement of 34:9mm.

  13. Genetics Home Reference: beta thalassemia

    MedlinePlus

    ... a blood disorder that reduces the production of hemoglobin . Hemoglobin is the iron-containing protein in red blood ... In people with beta thalassemia , low levels of hemoglobin lead to a lack of oxygen in many ...

  14. Peginterferon Beta-1a Injection

    MedlinePlus

    ... course of disease where symptoms flare up from time to time) of multiple sclerosis (MS, a disease in which ... peginterferon beta-1a injection at around the same time of day each time you inject it. Follow ...

  15. Interferon Beta-1b Injection

    MedlinePlus

    ... course of disease where symptoms flare up from time to time) of multiple sclerosis (MS, a disease in which ... interferon beta-1b injection at around the same time of day each time you inject it. Follow ...

  16. Questions Students Ask: Beta Decay.

    ERIC Educational Resources Information Center

    Koss, Jordan; Hartt, Kenneth

    1988-01-01

    Answers a student's question about the emission of a positron from a nucleus. Discusses the problem from the aspects of the uncertainty principle, beta decay, the Fermi Theory, and modern physics. (YP)

  17. Calibration beads containing luminescent lanthanide ion complexes

    NASA Astrophysics Data System (ADS)

    Leif, Robert C.; Jin, Dayong; Piper, James; Vallarino, Lidia M.; Williams, John W.; Yang, Sean; Zucker, Robert M.

    2008-02-01

    The reliability of lanthanide luminescence measurements, by both flow cytometry and digital microscopy, will be enhanced by the availability of narrow-band emitting lanthanide calibration beads. These beads can also be used to characterize spectrographic instruments, including microscopes. Methods: 0.5, 3, and 5 micron (µm) beads containing a luminescent europium-complex were manufactured and the luminescence distribution of the 5 µm beads was measured with a time-delayed luminescence flow cytometer and a timedelayed digital microscope. The distribution of the luminescence intensity from the europium-complex in individual beads was determined on optical sections by confocal microscopy. The emission spectra of the beads under UV excitation were determined with a PARISS® spectrophotometer. The kinetics of the luminescence bleaching caused by UV irradiation were measured under LED excitation with a fluorescence microscope. Results: The kinetics of UV bleaching were very similar for the 0.5, 3, and 5 µm beads. Emission peaks were found at 592, 616, and 685 nanometers (nm). The width of the principal peak at half-maximum (616 nm) was 9.9 nm. The luminescence lifetimes in water and in air were 340 and 460 microseconds (µs), respectively. The distribution of the europium- complex in the beads was homogeneous. Conclusions: The 5 µm beads can be used for spectral calibration of microscopes equipped with a spectrograph, as test particles for time-delayed luminescence flow cytometers, and possibly as labels for macromolecules and cells.

  18. CALET Data Processing and On-Orbit Detector Calibration

    NASA Astrophysics Data System (ADS)

    Asaoka, Yoichi

    2016-07-01

    The CALET (CALorimetric Electron Telescope), launched to the International Space Station (ISS) in August 2015 and accumulating scientific data since October 2015, aims at long duration observations of high-energy cosmic rays onboard the ISS. The CALET detector features the very thick calorimeter of 30 radiation-length which consists of imaging and total absorption calorimeters (IMC and TASC respectively). It will directly measure the cosmic-ray electron spectrum in the energy range of 1 GeV-20 TeV with 2% energy resolution. In addition, the instrument has capabilities to measure the spectra of gamma-rays, protons and nuclei well into the TeV range. Precise pointing direction is determined with an attached Advanced Stellar Camera (ASC). To operate the CALET onboard ISS, the CALET Ground Support Equipment (CALET-GSE) and Waseda CALET Operations Center (WCOC) have been established at JAXA and Waseda Univ., respectively. Scientific operations of CALET are planned in the WCOC taking into account the orbital variations of geomagnetic rigidity cutoff. Scheduled command sequence is utilized to control CALET observation mode on orbit. A calibration data trigger mode, such as recording pedestal and penetrating particle events, a low-energy electron trigger mode operating at high geomagnetic latitude, and other dedicated trigger modes are scheduled around the ISS orbit while maintaining the maximum exposure to high-energy electrons. Scientific raw data called CALET Level 0 data are generated from raw telemetry packets in the CALET-GSE on an hourly basis by correcting time-order and by completing the data set using stored data taken during loss of real-time telemetry downlink. Level 0 data are processed to CALET Level 1 data in the WCOC by interpreting all the raw packets and building cosmic-ray event data as well as house keeping data. Level 1 data are then distributed to the collaboration for scientific data analysis. Level 1 data analysis is focused on the detector

  19. Double beta decays of 106Cd

    NASA Astrophysics Data System (ADS)

    Suhonen, Jouni

    2011-12-01

    The two-neutrino (2ν2β) and neutrinoless (0ν2β) double beta decays of 106Cd are studied for the transitions to the ground state 0gs+ and 0+ and 2+ excited states in 106Pd by using realistic many-body wave functions calculated in the framework of the quasiparticle random-phase approximation. Effective, G-matrix-derived nuclear forces are used in realistic single-particle model spaces. All the possible channels, β+β+, β+EC, and ECEC, are discussed for both the 2ν2β and 0ν2β decays. The associated half-lives are computed and particular attention is devoted to the study of the detectability of the resonant neutrinoless double electron capture (R0νECEC) process in 106Cd. The calculations of the present article constitute the thus far most complete and up-to-date investigation of the double-beta-decay properties of 106Cd.

  20. Role of IL-1 beta and prostaglandins in beta 2-microglobulin-induced bone mineral dissolution.

    PubMed

    Moe, S M; Hack, B K; Cummings, S A; Sprague, S M

    1995-02-01

    beta 2-microglobulin (beta 2m) induces an osteoclast-mediated net calcium efflux from neonatal mouse calvariae which occurs only after 48 hours of incubation, suggesting that beta 2m acts via other growth factors. To further test this hypothesis, calvariae were incubated with and without beta 2m in the presence of the prostaglandin inhibitor indomethacin, anti-interleukin-1 beta antibody (anti-IL-1 beta), or interleukin-1 beta receptor antagonist (IL-1 beta RA). The addition of beta 2m to the culture medium stimulated, whereas indomethacin inhibited basal calcium efflux following 48 hours. However, the difference (delta) between the calcium efflux induced in calvariae incubated with and without beta 2m in basal medium and that in calvariae incubated with and without beta 2m in indomethacin supplemented medium was similar, suggesting a prostaglandin independent mechanism. There was a time dependent increase in PGE2 in basal medium which was unaffected by beta 2m. In contrast, pre-incubating calvariae with either anti-IL-1 beta or IL-1 beta RA did not alter basal calcium efflux but completely blocked the beta 2m induced calcium efflux. Anti-IL-1 beta had no effect on the basal release of beta-glucuronidase but partially blocked the beta 2m induced release of beta-glucuronidase. Thus, the beta 2m-induced calcium efflux observed in neonatal mouse calvariae is dependent on interleukin-1 beta but not prostaglandins.

  1. Medium Beta Superconducting Accelerating Structures

    SciTech Connect

    Jean Delayen

    2001-09-01

    While, originally, the development of superconducting structures was cleanly divided between low-beta resonators for heavy ions and beta=1 resonators for electrons, recent interest in protons accelerators (high and low current, pulsed and cw) has necessitated the development of structures that bridge the gap between the two. These activities have resulted both in new geometries and in the adaptation of well-known geometries optimized to this intermediate velocity range. Their characteristics and properties are reviewed.

  2. From Algol to Beta Lyrae

    NASA Astrophysics Data System (ADS)

    Plavec, M. J.

    Recognizing that the structure and evolutionary status of Beta Lyrae are much more complicated than for Algol, some of the problems of revealing its structure are discussed. The best model available at present considers Beta Lyrae as an Algol-type semi-detached system in a phase of fairly rapid mass transfer, i.e., younger than typical Algols. It is concluded that Beta Lyrae is not so special as it appears; some characteristics that are so puzzling in Beta Lyrae already appear in such classical Algols as U Cephei and RW Tauri. The mass-accreting components in these systems are surrounded by a hot, turbulent layer which probably expands and which is the seat of emission lines of fairly high ionization discovered in the far ultraviolet. In Beta Lyrae and the so-called W Serpenis stars, the circumstellar hot turbulent shell is much more extensive and probably also denser - a kind of 'superchromosphere'. In Beta Lyrae, a thick disk probably completely surrounds and hides the accreting star proper.

  3. Metal diaphragm used to calibrate miniature transducers

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Dynamic comparative calibration system measures response of miniature pressure transducers. The system is composed of an electromechanically driven metal diaphragm, a calibrated and an uncalibrated transducer and an oscillator.

  4. Calibration Software for Use with Jurassicprok

    NASA Technical Reports Server (NTRS)

    Chapin, Elaine; Hensley, Scott; Siqueira, Paul

    2004-01-01

    The Jurassicprok Interferometric Calibration Software (also called "Calibration Processor" or simply "CP") estimates the calibration parameters of an airborne synthetic-aperture-radar (SAR) system, the raw measurement data of which are processed by the Jurassicprok software described in the preceding article. Calibration parameters estimated by CP include time delays, baseline offsets, phase screens, and radiometric offsets. CP examines raw radar-pulse data, single-look complex image data, and digital elevation map data. For each type of data, CP compares the actual values with values expected on the basis of ground-truth data. CP then converts the differences between the actual and expected values into updates for the calibration parameters in an interferometric calibration file (ICF) and a radiometric calibration file (RCF) for the particular SAR system. The updated ICF and RCF are used as inputs to both Jurassicprok and to the companion Motion Measurement Processor software (described in the following article) for use in generating calibrated digital elevation maps.

  5. Summary of OARE flight calibration measurements

    NASA Astrophysics Data System (ADS)

    Blanchard, Robert C.; Nicholson, John Y.

    1995-01-01

    To date, the Orbital Acceleration Research Experiment (OARE) has flown on the shuttle orbiter for five missions; namely, STS-40, STS-50, STS-58, STS-62, and STS-65. The OARE instrument system contains a three-axis accelerometer which can resolve accelerations to the nano-g (10(exp -9) g) level and a full calibration station to permit in situ bias and scale factor calibration measurements. This calibration capability eliminates the large uncertainty encountered with accelerometers flown in the past on the orbiter which use ground-based calibrations to provide absolute acceleration measurements. A detailed flight data report presentation is given for the OARE calibration measurements from all missions, along with an estimate of the calibration errors. The main aim is to collect, process, and present the calibration data in one archival report. These calibration data are the necessary key ingredient to produce the absolute acceleration levels from the OARE acceleration flight data.

  6. Calibration intervals at Bendix Kansas City

    SciTech Connect

    James, R.T.

    1980-01-01

    The calibration interval evaluation methods and control in each calibrating department of the Bendix Corp., Kansas City Division is described, and a more detailed description of those employed in metrology is provided.

  7. Automated Attitude Sensor Calibration: Progress and Plans

    NASA Technical Reports Server (NTRS)

    Sedlak, Joseph; Hashmall, Joseph

    2004-01-01

    This paper describes ongoing work a NASA/Goddard Space Flight Center to improve the quality of spacecraft attitude sensor calibration and reduce costs by automating parts of the calibration process. The new calibration software can autonomously preview data quality over a given time span, select a subset of the data for processing, perform the requested calibration, and output a report. This level of automation is currently being implemented for two specific applications: inertial reference unit (IRU) calibration and sensor alignment calibration. The IRU calibration utility makes use of a sequential version of the Davenport algorithm. This utility has been successfully tested with simulated and actual flight data. The alignment calibration is still in the early testing stage. Both utilities will be incorporated into the institutional attitude ground support system.

  8. Automatic calibration system for pressure transducers

    NASA Technical Reports Server (NTRS)

    1968-01-01

    Fifty-channel automatic pressure transducer calibration system increases quantity and accuracy for test evaluation calibration. The pressure transducers are installed in an environmental tests chamber and manifolded to connect them to a pressure balance which is uniform.

  9. Fission foil detector calibrations with high energy protons

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.

    1995-01-01

    Fission foil detectors (FFD's) are passive devices composed of heavy metal foils in contact with muscovite mica films. The heavy metal nuclei have significant cross sections for fission when irradiated with neutrons and protons. Each isotope is characterized by threshold energies for the fission reactions and particular energy-dependent cross sections. In the FFD's, fission fragments produced by the reactions are emitted from the foils and create latent particle tracks in the adjacent mica films. When the films are processed surface tracks are formed which can be optically counted. The track densities are indications of the fluences and spectra of neutrons and/or protons. In the past, detection efficiencies have been calculated using the low energy neutron calibrated dosimeters and published fission cross sections for neutrons and protons. The problem is that the addition of a large kinetic energy to the (n,nucleus) or (p,nucleus) reaction could increase the energies and ranges of emitted fission fragments and increase the detector sensitivity as compared with lower energy neutron calibrations. High energy calibrations are the only method of resolving the uncertainties in detector efficiencies. At high energies, either proton or neutron calibrations are sufficient since the cross section data show that the proton and neutron fission cross sections are approximately equal. High energy proton beams have been utilized (1.8 and 4.9 GeV, 80 and 140 MeV) for measuring the tracks of fission fragments emitted backward and forward.

  10. Jet Reconstruction and Calibration in the ATLAS Calorimeters

    SciTech Connect

    Jorgensen Roca, Sigrid

    2006-10-27

    Many physics studies in ATLAS require precise reconstruction and calibration of particle jet kinematics. Among these are the reconstruction of the top quark mass, the search for the Higgs boson, and possible supersymmetric particles. The ATLAS calorimeter system has been designed to meet these requirements across a wide acceptance in pseudorapidity (|{eta}|<5). Different calorimeter technologies are applied in different rapidity regions to optimize the performance with respect to coverage, containment, highest possible spatial granularity, and the best possible energy resolution, in the difficult and changing experimental conditions characteristic for each of these regions.In this talk we briefly illustrate the ATLAS calorimeter features most relevant for the jet measurement. The general approach to calorimeter jet calibration is two-fold. First, the jet signal shape is used to correct for detector effects such as non-compensation and energy losses in inactive materials. This followed by corrections for biases introduced by the jet clustering algorithms and effects from the collision physics environment. We intend to discuss this calibration procedure and the different strategies available to implement it, in the context of the evaluation of the jet reconstruction performance for various available jet clustering algorithms, including a fixed cone and the Kt algorithm. A focus in this discussion is on the expected initial run condition at ATLAS start-up.

  11. Novel measure for the calibration of laser Doppler flowmetry devices

    NASA Astrophysics Data System (ADS)

    Dunaev, Andrey V.; Zherebtsov, Evgeny A.; Rogatkin, Dmitrii A.; Stewart, Neil A.; Sokolovski, Sergei G.; Rafailov, Edik U.

    2014-03-01

    The metrological basis for optical non-invasive diagnostic devices is an unresolved issue. A major challenge for laser Doppler flowmetry (LDF) is the need to compare the outputs from individual devices and various manufacturers to identify variations useful in clinical diagnostics. The most common methods for instrument calibration are simulants or phantoms composed of colloids of light-scattering particles which simulate the motion of red blood cells based on Brownian motion. However, such systems have limited accuracy or stability and cannot calibrate for the known rhythmic components of perfusion (0.0095-1.6 Hz). To solve this problem, we propose the design of a novel technique based on the simulation of moving particles using an electromechanical transducer, in which a precision piezoelectric actuator is used (e.g., P-602.8SL with maximum movement less than 1 mm). In this system, Doppler shift is generated in the layered structure of different solid materials with different optical light diffusing properties. This comprises a fixed, light transparent upper plane-parallel plate and an oscillating fluoroplastic (PTFE) disk. Preliminary studies on this experimental setup using the LDF-channel of a "LAKK-M" system demonstrated the detection of the linear portion (0-10 Hz with a maximum signal corresponding to Doppler shift of about 20 kHz) of the LDF-signal from the oscillating frequency of the moving layer. The results suggest the possibility of applying this technique for the calibration of LDF devices.

  12. Beta-decay rates

    NASA Astrophysics Data System (ADS)

    Borzov, I. N.

    2006-10-01

    Major astrophysical applications involve a huge number of exotic nuclei. Their beta-decay properties play a crucial role in stellar explosive events. An important effort has been developed in last decades to measure the masses and β-decay properties of very neutron-rich nuclei at radioactive nuclear beam facilities. However, most of them cannot be synthesized in terrestrial laboratories and only theoretical predictions can fill the gap. We will concentrate mainly on the β-decay rates needed for stellar r-process modeling and for performing the RNB experiments. An overview of the microscopic approaches to the β-decay strength function is given. The continuum QRPA approach based on the self-consistent ground state description in the framework of the density functional theory is outlined. For the first time, a systematic study of the total β-decay half-lives and delayed neutron emission probabilities takes into account the Gamow Teller and first-forbidden transitions. Due to the shell configuration effects, the first-forbidden decays have a strong impact on the β-decay characteristics of the r-process relevant nuclei at Z≈28, N>50; Z⩾50, N>82 and Z=60 70, N≈126. Suppression of the delayed neutron emission probability is found in nuclei with the neutron excess bigger than one major shell. The effect originates from the high-energy first-forbidden transitions to the states outside the (Q-B)-window in the daughter nuclei. The performance of existing global models for the nuclides near the r-process paths is critically analyzed and confronted with the recent RIB experiments in the regions of 78Ni, 132Sn and “east” of 208Pb.

  13. Alpha-beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    NASA Astrophysics Data System (ADS)

    Wengrowicz, U.; Amidan, D.; Orion, I.

    2016-08-01

    A new approach for a simultaneous alpha-beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha-beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha-beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  14. Enhanced Activity of Nanocrystalline Beta Zeolite for Acylation of Veratrole with Acetic Anhydride.

    PubMed

    Aisha Mahmood Abdulkareem, Al-Turkustani; Selvin, Rosilda

    2016-04-01

    Friedel-Craft acylation of veratrole using homogeneous acid catalysts such as AlCl3, FeCl3, ZnCl2, and HF etc. produces acetoveratrone, (3',4'-dimethoxyacetophenone), which is the intermediate for synthesis of papavarine alkaloids. The problems associated with these homogeneous catalysts can be overcome by using heterogeneous solid catalysts. Since acetoveratrone is a larger molecule, large pore Beta zeolites with smaller particle sizes are beneficial for the liquid-phase acylation of veratrole, for easy diffusion of reactants and products. The present study aims in the acylation of veratrole with acetic anhydride using nanocrystalline Beta Zeolite catalyst. A systematic investigation of the effects of various reaction parameters was done. The catalysts were characterized for their structural features by using XRD, TEM and DLS analyses. The catalytic activity of nanocrystalline Beta zeolite was compared with commercial Beta zeolite for the acylation and was found that nanocrystalline Beta zeolite possessed superior activity.

  15. Enhanced Activity of Nanocrystalline Beta Zeolite for Acylation of Veratrole with Acetic Anhydride.

    PubMed

    Aisha Mahmood Abdulkareem, Al-Turkustani; Selvin, Rosilda

    2016-04-01

    Friedel-Craft acylation of veratrole using homogeneous acid catalysts such as AlCl3, FeCl3, ZnCl2, and HF etc. produces acetoveratrone, (3',4'-dimethoxyacetophenone), which is the intermediate for synthesis of papavarine alkaloids. The problems associated with these homogeneous catalysts can be overcome by using heterogeneous solid catalysts. Since acetoveratrone is a larger molecule, large pore Beta zeolites with smaller particle sizes are beneficial for the liquid-phase acylation of veratrole, for easy diffusion of reactants and products. The present study aims in the acylation of veratrole with acetic anhydride using nanocrystalline Beta Zeolite catalyst. A systematic investigation of the effects of various reaction parameters was done. The catalysts were characterized for their structural features by using XRD, TEM and DLS analyses. The catalytic activity of nanocrystalline Beta zeolite was compared with commercial Beta zeolite for the acylation and was found that nanocrystalline Beta zeolite possessed superior activity. PMID:27451793

  16. The search for Majorana neutrinos with neutrinoless double beta decays: From CUORICINO to LUCIFER experiment

    SciTech Connect

    Bellini, F.

    2012-11-20

    The study of neutrino properties is one of the fundamental challenges in particle physics nowadays. Fifty years of investigations established that neutrinos are massive but the absolute mass scale has not yet been measured. Moreover its true nature is still unknown. Is the neutrino its own antiparticle (thus violating the lepton number) as proposed by Majorana in 1937? The only way to probe the neutrino nature is through the observation of Neutrinoless Double Beta Decay (0{nu}{beta}{beta}), a very rare spontaneous nuclear transition which emits two electrons and no neutrinos. In this paper, after a brief introduction to the theoretical framework of Majorana's neutrino, a presentation of experimental challenges posed by 0{nu}{beta}{beta} search will be given as well as an overview of present status and future perpectives of experiments.

  17. Extending the Range for Force Calibration in Magnetic Tweezers

    PubMed Central

    Daldrop, Peter; Brutzer, Hergen; Huhle, Alexander; Kauert, Dominik J.; Seidel, Ralf

    2015-01-01

    Magnetic tweezers are a wide-spread tool used to study the mechanics and the function of a large variety of biomolecules and biomolecular machines. This tool uses a magnetic particle and a strong magnetic field gradient to apply defined forces to the molecule of interest. Forces are typically quantified by analyzing the lateral fluctuations of the biomolecule-tethered particle in the direction perpendicular to the applied force. Since the magnetic field pins the anisotropy axis of the particle, the lateral fluctuations follow the geometry of a pendulum with a short pendulum length along and a long pendulum length perpendicular to the field lines. Typically, the short pendulum geometry is used for force calibration by power-spectral-density (PSD) analysis, because the movement of the bead in this direction can be approximated by a simple translational motion. Here, we provide a detailed analysis of the fluctuations according to the long pendulum geometry and show that for this direction, both the translational and the rotational motions of the particle have to be considered. We provide analytical formulas for the PSD of this coupled system that agree well with PSDs obtained in experiments and simulations and that finally allow a faithful quantification of the magnetic force for the long pendulum geometry. We furthermore demonstrate that this methodology allows the calibration of much larger forces than the short pendulum geometry in a tether-length-dependent manner. In addition, the accuracy of determination of the absolute force is improved. Our force calibration based on the long pendulum geometry will facilitate high-resolution magnetic-tweezers experiments that rely on short molecules and large forces, as well as highly parallelized measurements that use low frame rates. PMID:25992733

  18. Extending the range for force calibration in magnetic tweezers.

    PubMed

    Daldrop, Peter; Brutzer, Hergen; Huhle, Alexander; Kauert, Dominik J; Seidel, Ralf

    2015-05-19

    Magnetic tweezers are a wide-spread tool used to study the mechanics and the function of a large variety of biomolecules and biomolecular machines. This tool uses a magnetic particle and a strong magnetic field gradient to apply defined forces to the molecule of interest. Forces are typically quantified by analyzing the lateral fluctuations of the biomolecule-tethered particle in the direction perpendicular to the applied force. Since the magnetic field pins the anisotropy axis of the particle, the lateral fluctuations follow the geometry of a pendulum with a short pendulum length along and a long pendulum length perpendicular to the field lines. Typically, the short pendulum geometry is used for force calibration by power-spectral-density (PSD) analysis, because the movement of the bead in this direction can be approximated by a simple translational motion. Here, we provide a detailed analysis of the fluctuations according to the long pendulum geometry and show that for this direction, both the translational and the rotational motions of the particle have to be considered. We provide analytical formulas for the PSD of this coupled system that agree well with PSDs obtained in experiments and simulations and that finally allow a faithful quantification of the magnetic force for the long pendulum geometry. We furthermore demonstrate that this methodology allows the calibration of much larger forces than the short pendulum geometry in a tether-length-dependent manner. In addition, the accuracy of determination of the absolute force is improved. Our force calibration based on the long pendulum geometry will facilitate high-resolution magnetic-tweezers experiments that rely on short molecules and large forces, as well as highly parallelized measurements that use low frame rates.

  19. Calibration of BGO Calorimeter of the DAMPE in Space

    NASA Astrophysics Data System (ADS)

    Wang, Chi

    2016-07-01

    The Dark Matter Particle Explore (DAMPE) is a satellite based experiment which launched on December 2015 and aims at indirect searching for dark matter by measuring the spectra of high energy e±, γ from 5GeV up to 10TeV originating from deep space. The 3D imaging BGO calorimeter of DAMPE was designed to precisely measurement the primary energy of the electromagnetic particle and provides a highly efficient rejection of the hadronic background by reconstruct the longitudinal and lateral profiles of showers. To achieve the expected accuracy on the energy measurement, each signal channel has to be calibrated. The energy equalization is performed using the signal that Minimum Ionizing Particles (MIP) leave in each BGO bar, the MIPs measurement method with orbit data and, data quality, time stability using MIPs data will be presented, too.

  20. [Serum beta 2 microglobulin (beta 2M) following renal transplantation].

    PubMed

    Pacheco-Silva, A; Nishida, S K; Silva, M S; Ramos, O L; Azjen, H; Pereira, A B

    1994-01-01

    Although there was an important improvement in graft and patient survival the last 10 years, graft rejection continues to be a major barrier to the success of renal transplantation. Identification of a laboratory test that could help to diagnose graft rejection would facilitate the management of renal transplanted patients. PURPOSE--To evaluate the utility of monitoring serum beta 2M in recently transplanted patients. METHODS--We daily determined serum beta 2M levels in 20 receptors of renal grafts (10 from living related and 10 from cadaveric donors) and compared them to their clinical and laboratory evolution. RESULTS--Eight patients who presented immediate good renal function following grafting and did not have rejection had a mean serum beta 2M of 3.7 mg/L on the 4th day post transplant. The sensitivity of the test for the diagnosis of acute rejection was 87.5%, but the specificity was only 46%. Patients who presented acute tubular necrosis (ATN) without rejection had a progressive decrease in their serum levels of beta 2M, while their serum creatinine changed as they were dialyzed. In contrast, patients with ATN and concomitance of acute rejection or CSA nephrotoxicity presented elevated beta 2M and creatinine serum levels. CONCLUSION--Daily monitoring of serum beta 2M does not improve the ability to diagnose acute rejection in patients with good renal function. However, serum beta 2M levels seemed to be useful in diagnosing acute rejection or CSA nephrotoxicity in patients with ATN. PMID:7787867