Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.
Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan
2011-01-01
With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Sound-direction identification with bilateral cochlear implants.
Neuman, Arlene C; Haravon, Anita; Sislian, Nicole; Waltzman, Susan B
2007-02-01
The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. Eight adults who were bilateral users of Nucleus 24 Contour devices participated in the study. All had received implants in both ears in a single surgery. Sound-direction identification was measured in a large classroom by using a nine-loudspeaker array. Localization was tested in three listening conditions (bilateral cochlear implants, left cochlear implant, and right cochlear implant), using two different stimuli (a speech stimulus and pink noise bursts) in a repeated-measures design. Sound-direction identification accuracy was significantly better when using two implants than when using a single implant. The mean root-mean-square error was 29 degrees for the bilateral condition, 54 degrees for the left cochlear implant, and 46.5 degrees for the right cochlear implant condition. Unilateral accuracy was similar for right cochlear implant and left cochlear implant performance. Sound-direction identification performance was similar for speech and pink noise stimuli. The data obtained in this study add to the growing body of evidence that sound-direction identification with bilateral cochlear implants is better than with a single implant. The similarity in localization performance obtained with the speech and pink noise supports the use of either stimulus for measuring sound-direction identification.
United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.
Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark
2013-11-01
Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.
Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.
Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko
2017-01-01
There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total suppression of tinnitus compared with their unilateral situation. While bilateral cochlear implantation can have a positive effect on preoperative tinnitus complaints, the induction of (temporary or permanent) tinnitus was also reported. Dutch Trial Register NTR1722.
Early Vocabulary Development in Children with Bilateral Cochlear Implants
ERIC Educational Resources Information Center
Välimaa, Taina; Kunnari, Sari; Laukkanen-Nevala, Päivi; Lonka, Eila
2018-01-01
Background: Children with unilateral cochlear implants (CIs) may have delayed vocabulary development for an extended period after implantation. Bilateral cochlear implantation is reported to be associated with improved sound localization and enhanced speech perception in noise. This study proposed that bilateral implantation might also promote…
A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.
Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan
2015-02-01
To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.
ERIC Educational Resources Information Center
Reeder, Ruth M.; Firszt, Jill B.; Cadieux, Jamie H.; Strube, Michael J.
2017-01-01
Purpose: Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization…
Sequential Bilateral Cochlear Implantation in a Patient with Bilateral Meniere’s Disease
Holden, Laura K.; Neely, J. Gail; Gotter, Brenda D.; Mispagel, Karen M.; Firszt, Jill B.
2012-01-01
This case study describes a 45 year old female with bilateral, profound sensorineural hearing loss due to Meniere’s disease. She received her first cochlear implant in the right ear in 2008 and the second cochlear implant in the left ear in 2010. The case study examines the enhancement to speech recognition, particularly in noise, provided by bilateral cochlear implants. Speech recognition tests were administered prior to obtaining the second implant and at a number of test intervals following activation of the second device. Speech recognition in quiet and noise as well as localization abilities were assessed in several conditions to determine bilateral benefit and performance differences between ears. The results of the speech recognition testing indicated a substantial improvement in the patient’s ability to understand speech in noise and her ability to localize sound when using bilateral cochlear implants compared to using a unilateral implant or an implant and a hearing aid. In addition, the patient reported considerable improvement in her ability to communicate in daily life when using bilateral implants versus a unilateral implant. This case suggests that cochlear implantation is a viable option for patients who have lost their hearing to Meniere’s disease even when a number of medical treatments and surgical interventions have been performed to control vertigo. In the case presented, bilateral cochlear implantation was necessary for this patient to communicate successfully at home and at work. PMID:22463939
Chang, Young-Soo; Hong, Sung Hwa; Kim, Eun Yeon; Choi, Ji Eun; Chung, Won-Ho; Cho, Yang-Sun; Moon, Il Joon
2018-05-18
Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1+HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1+CI2). The good Performance Group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1+CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Compared to the CI1+HA, CI1+CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio=4.38, 95% confidence interval - 95%=1.07-17.93, p=0.04). The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential cochlear implant. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Escorihuela García, Vicente; Pitarch Ribas, María Ignacia; Llópez Carratalá, Ignacio; Latorre Monteagudo, Emilia; Morant Ventura, Antonio; Marco Algarra, Jaime
2016-01-01
The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localization and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducted a statistical comparison of both groups in the audiometry, IT-Mais, Nottingham, LittlEars scales and verbal tests. No significant differences in hearing thresholds and questionnaires between unilateral and bilateral implantation were detected in either the first or second year. Verbal tests do show statistically significant differences: children with bilateral cochlear implant obtain 100% recognition of disyllabic and phrases within 2-3 years after implantation whilst children with one implant do not obtain those results at 5 years after surgery. No differences between simultaneous and sequential bilateral implantation were detected. We emphasize the importance of ensuring good early audiological screening, to carry out an early and bilateral cochlear implantation with the consequent development of audio-language skills similar to normal hearing children. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.
Alsanosi, A A
2015-09-01
To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.
Cullington, H E; Bele, D; Brinton, J C; Cooper, S; Daft, M; Harding, J; Hatton, N; Humphries, J; Lutman, M E; Maddocks, J; Maggs, J; Millward, K; O'Donoghue, G; Patel, S; Rajput, K; Salmon, V; Sear, T; Speers, A; Wheeler, A; Wilson, K
2017-01-01
To assess longitudinal outcomes in a large and varied population of children receiving bilateral cochlear implants both simultaneously and sequentially. This observational non-randomized service evaluation collected localization and speech recognition in noise data from simultaneously and sequentially implanted children at four time points: before bilateral cochlear implants or before the sequential implant, 1 year, 2 years, and 3 years after bilateral implants. No inclusion criteria were applied, so children with additional difficulties, cochleovestibular anomalies, varying educational placements, 23 different home languages, a full range of outcomes and varying device use were included. 1001 children were included: 465 implanted simultaneously and 536 sequentially, representing just over 50% of children receiving bilateral implants in the UK in this period. In simultaneously implanted children the median age at implant was 2.1 years; 7% were implanted at less than 1 year of age. In sequentially implanted children the interval between implants ranged from 0.1 to 14.5 years. Children with simultaneous bilateral implants localized better than those with one implant. On average children receiving a second (sequential) cochlear implant showed improvement in localization and listening in background noise after 1 year of bilateral listening. The interval between sequential implants had no effect on localization improvement although a smaller interval gave more improvement in speech recognition in noise. Children with sequential implants on average were able to use their second device to obtain spatial release from masking after 2 years of bilateral listening. Although ranges were large, bilateral cochlear implants on average offered an improvement in localization and speech perception in noise over unilateral implants. These data represent the diverse population of children with bilateral cochlear implants in the UK from 2010 to 2012. Predictions of outcomes for individual patients are not possible from these data. However, there are no indications to preclude children with long inter-implant interval having the chance of a second cochlear implant.
Hearing rehabilitation with a binaural cochlear implant in a patient with Erdheim-Chester disease.
Querat, Charlotte; Thai-Van, Hung; Durand, Denis Vital; Cotton, François; Gallego, Stéphane; Truy, Eric
2015-09-01
Erdheim-Chester disease (ECD) is a rare non-Langerhans form of histiocytosis. This paper reports an exceptional case of bilateral neural involvement, responsible for profound hearing loss. Bilateral cochlear implantation was performed. We present a 57-year-old man affected by ECD with profound bilateral hearing loss. The patient underwent cochlear implantation with a binaural Digisonic(®) cochlear implant, 7 years after the initial diagnosis. Speech intelligibility rose to a plateau after about 6 months of cochlear implant use. The average outcome of speech intelligibility over time was 55% for dissyllabic words without lip reading, and 70% for sentences. Perception score decreased before the patient died from ECD. A description of the ECD and its otological manifestations is presented. This paper reports the effective hearing rehabilitation of profound bilateral hearing loss by the means of a binaural Digisonic(®) cochlear implant.
Cochlear Implantation after Bilateral Transverse Temporal Bone Fractures
Shin, Jong-Heon; Park, SooChan; Baek, Sam-Hyun
2008-01-01
Patients deafened by a severe head injury are rarely encountered. We report a case of a 65-yr-old man with bilateral transverse temporal bone fractures due to head injury. He underwent cochlear implant and achieved a satisfactory auditory rehabilitation. Imaging studies of temporal bone before performing a cochlear implantation provide important information on a patient with bilateral temporal bone fractures. Cochlear implantations with careful planning in such a patient may be a very effective method for aural rehabilitation. PMID:19434252
Dunn, Camille C.; Perreau, Ann; Gantz, Bruce; Tyler, Richard
2009-01-01
Background Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant. Purpose The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech in noise test with spatially-separate noise sources. Research Design Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use. Results Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all eleven subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid. Conclusion Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for the purpose of localization and speech perception in noise. PMID:20085199
Dunn, Camille C; Perreau, Ann; Gantz, Bruce; Tyler, Richard S
2010-01-01
Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant. The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech-in-noise test with spatially separate noise sources. Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use. Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all 11 subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid. Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for the purpose of localization and speech perception in noise.
Gordon, Karen A.; Deighton, Michael R.; Abbasalipour, Parvaneh; Papsin, Blake C.
2014-01-01
There are significant challenges to restoring binaural hearing to children who have been deaf from an early age. The uncoordinated and poor temporal information available from cochlear implants distorts perception of interaural timing differences normally important for sound localization and listening in noise. Moreover, binaural development can be compromised by bilateral and unilateral auditory deprivation. Here, we studied perception of both interaural level and timing differences in 79 children/adolescents using bilateral cochlear implants and 16 peers with normal hearing. They were asked on which side of their head they heard unilaterally or bilaterally presented click- or electrical pulse- trains. Interaural level cues were identified by most participants including adolescents with long periods of unilateral cochlear implant use and little bilateral implant experience. Interaural timing cues were not detected by new bilateral adolescent users, consistent with previous evidence. Evidence of binaural timing detection was, for the first time, found in children who had much longer implant experience but it was marked by poorer than normal sensitivity and abnormally strong dependence on current level differences between implants. In addition, children with prior unilateral implant use showed a higher proportion of responses to their first implanted sides than children implanted simultaneously. These data indicate that there are functional repercussions of developing binaural hearing through bilateral cochlear implants, particularly when provided sequentially; nonetheless, children have an opportunity to use these devices to hear better in noise and gain spatial hearing. PMID:25531107
Vecchiato, G; Maglione, A G; Scorpecci, A; Malerba, P; Marsella, P; Di Francesco, G; Vitiello, S; Colosimo, A; Babiloni, Fabio
2012-01-01
Interestingly, the international debate about the quality of music fruition for cochlear implanted users does not take into account the hypothesis that bilateral users could perceive music in a more pleasant way with respect to monolateral users. In this scenario, the aim of the present study was to investigate if cerebral signs of pleasantness during music perception in healthy child are similar to those observed in monolateral and in bilateral cochlear implanted users. In fact, previous observations in literature on healthy subjects have indicated that variations of the frontal EEG alpha activity are correlated with the perceived pleasantness of the sensory stimulation received (approach-withdrawal theory). In particular, here we described differences between cortical activities estimated in the alpha frequency band for a healthy child and in patients having a monolateral or a bilateral cochlear implant during the fruition of a musical cartoon. The results of the present analysis showed that the alpha EEG asymmetry patterns observed in a healthy child and that of a bilateral cochlear implanted patient are congruent with the approach-withdrawal theory. Conversely, the scalp topographic distribution of EEG power spectra in the alpha band resulting from the monolateral cochlear user presents a different EEG pattern from the normal and bilateral implanted patients. Such differences could be explained at the light of the approach-withdrawal theory. In fact, the present findings support the hypothesis that a monolateral cochlear implanted user could perceive the music in a less pleasant way when compared to a healthy subject or to a bilateral cochlear user.
Bilateral Cochlear Implantation in Children: Experiences and Considerations
ERIC Educational Resources Information Center
Bohnert, Andrea; Spitzlei, Vera; Lippert, Karl L.; Keilmann, Annerose
2006-01-01
Between 2000 and 2006, the University Clinic for Ear Nose and Throat and Communication Disorders in Mainz, Germany, performed 41 bilateral cochlear implantations in children. This article addresses some of the factors to be considered in a decision to bilaterally implant a child, including the age of the child at the first implant, the length of…
Bilateral cochlear implantation in the ferret: A novel animal model for behavioral studies
Hartley, Douglas E.H.; Vongpaisal, Tara; Xu, Jin; Shepherd, Robert K.; King, Andrew J.; Isaiah, Amal
2010-01-01
Bilateral cochlear implantation has recently been introduced with the aim of improving both speech perception in background noise and sound localization. Although evidence suggests that binaural perception is possible with two cochlear implants, results in humans are variable. To explore potential contributing factors to these variable outcomes, we have developed a behavioral animal model of bilateral cochlear implantation in a novel species, the ferret. Although ferrets are ideally suited to psychophysical and physiological assessments of binaural hearing, cochlear implantation has not been previously described in this species. This paper describes the techniques of deafening with aminoglycoside administration, surgical implantation of an intracochlear array and chronic intracochlear electrical stimulation with monitoring for electrode integrity and efficacy of stimulation. Experiments have been presented elsewhere to show that the model can be used to study behavioral and electrophysiological measures of binaural hearing in chronically implanted animals. This paper demonstrates that cochlear implantation and chronic intracochlear electrical stimulation are both safe and effective in ferrets, opening up the possibility of using this model to study potential protective effects of bilateral cochlear implantation on the developing central auditory pathway. Since ferrets can be used to assess psychophysical and physiological aspects of hearing along with the structure of the auditory pathway in the same animals, we anticipate that this model will help develop novel neuroprosthetic therapies for use in humans. PMID:20576507
New Criteria of Indication and Selection of Patients to Cochlear Implant
Sampaio, André L. L.; Araújo, Mercêdes F. S.; Oliveira, Carlos A. C. P.
2011-01-01
Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant. PMID:22013448
ERIC Educational Resources Information Center
Reeder, Ruth M.; Firszt, Jill B.; Holden, Laura K.; Strube, Michael J.
2014-01-01
Purpose: The purpose of this study was to examine the rate of progress in the 2nd implanted ear as it relates to the 1st implanted ear and to bilateral performance in adult sequential cochlear implant recipients. In addition, this study aimed to identify factors that contribute to patient outcomes. Method: The authors performed a prospective…
Samuel, V; Gamble, C; Cullington, H; Bathgate, F; Bennett, E; Coop, N; Cropper, J; Emond, A; Kentish, R; Edwards, L
2016-11-01
In contrast to previous clinical practice, current guidelines recommend bilateral cochlear implantation in children, resulting in a cohort of children who initially received one implant, but have subsequently had a second, contralateral implant. This study aimed to explore satisfaction and quality of life in children implanted simultaneously or sequentially. A novel measure of satisfaction and quality of life following paediatric bilateral cochlear implantation (the Brief Assessment of Parental Perception; BAPP) was developed and preliminary validation undertaken as part of a large, national project of bilateral implantation. Children's parents completed the measure yearly for up to three years following implantation. Children from 14 UK implant centres were recruited into the study; data were available for 410 children one year post-implantation. The BAPP was found to have good face and convergent validity, and internal consistency. Results indicated very high levels of satisfaction with the devices, and improvements in quality of life. However there was evidence that children implanted sequentially were less willing to wear their second implant in the first two years than those children receiving simultaneous implants. Simultaneous and sequential cochlear implants have a positive impact on the quality of life of deaf children.
Steel, Morrison M; Papsin, Blake C; Gordon, Karen A
2015-01-01
Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds) from their bilateral implants and if this "binaural fusion" reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz). Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing.
Bilateral and Unilateral Cochlear Implant Users Compared on Speech Perception in Noise
Dunn, Camille C.; Noble, William; Tyler, Richard S.; Kordus, Monika; Gantz, Bruce J.; Ji, Haihong
2009-01-01
Objective Compare speech performance in noise with matched bilateral (CICI) and unilateral (CI-Only) cochlear implant users. Design Thirty CICI and 30 CI-Only subjects were tested on a battery of speech perception tests in noise that utilize an 8-loudspeaker array. Results On average, CICI subject's performance with speech in noise was significantly better than the CI-Only subjects. Conclusion The CICI group showed significantly better performance on speech perception in noise compared to the CI-Only subjects, supporting the hypothesis that bilateral cochlear implantation is more beneficial than unilateral implantation. PMID:19858720
Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez
2016-01-01
The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Steel, Morrison M.; Papsin, Blake C.; Gordon, Karen A.
2015-01-01
Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds) from their bilateral implants and if this “binaural fusion” reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz). Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing. PMID:25668423
Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.
Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr
2017-01-01
Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.
Reeder, Ruth M; Firszt, Jill B; Cadieux, Jamie H; Strube, Michael J
2017-01-01
Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization abilities. A prospective longitudinal study included 24 bilaterally implanted children (mean ear surgeries at 5.11 and 14.25 years). Test intervals were every 3-6 months through 24 months postbilateral. Test conditions were each ear and bilaterally for speech recognition and localization. Overall, the rate of progress for the second implanted ear was gradual. Improvements in quiet continued through the second year of bilateral use. Improvements in noise were more modest and leveled off during the second year. On all measures, results from the second ear were poorer than the first. Bilateral scores were better than either ear alone for all measures except sentences in quiet and localization. Older sequentially implanted children with several years between surgeries may obtain speech understanding in the second implanted ear; however, performance may be limited and rate of progress gradual. Continued contralateral ear hearing aid use and reduced time between surgeries may enhance outcomes.
Chang, David T; Ko, Alvin B; Murray, Gail S; Arnold, James E; Megerian, Cliff A
2010-07-01
(1) To analyze if socioeconomic status influences access to cochlear implantation in an environment with adequate Medicaid reimbursement. (2) To determine the impact of socioeconomic status on outcomes after unilateral cochlear implantation. Retrospective cohort study. University Hospitals Case Medical Center and Rainbow Babies and Children's Hospital (tertiary referral center), Cleveland, Ohio. Pediatric patients (age range, newborn to 18 years) who received unilateral cochlear implantation during the period 1996 to 2008. Access to cochlear implantation after referral to a cochlear implant center, postoperative complications, compliance with follow-up appointments, and access to sequential bilateral cochlear implantation. A total of 133 pediatric patients were included in this study; 64 were Medicaid-insured patients and 69 were privately insured patients. There was no statistical difference in the odds of initial cochlear implantation, age at referral, or age at implantation between the 2 groups. The odds of prelingual Medicaid-insured patients receiving sequential bilateral cochlear implantation was less than half that of the privately insured group (odds ratio [OR], 0.43; P = .03). The odds of complications in Medicaid-insured children were almost 5-fold greater than the odds for privately insured children (OR, 4.6; P = .03). There were 10 complications in 51 Medicaid-insured patients (19.6%) as opposed to 3 in 61 privately insured patients (4.9%). Medicaid-insured patients missed substantially more follow-up appointments overall (35% vs 23%) and more consecutive visits (1.9 vs 1.1) compared with privately insured patients. In an environment with adequate Medicaid reimbursement, eligible children have equal access to cochlear implantation, regardless of socioeconomic background. However, lower socioeconomic background is associated with higher rates of postoperative complications, worse follow-up compliance, and lower rates of sequential bilateral implantation, observed herein in Medicaid-insured patients. These findings present opportunities for cochlear implant centers to create programs to address such downstream disparities.
Cochlear implantation in adults: a systematic review and meta-analysis.
Gaylor, James M; Raman, Gowri; Chung, Mei; Lee, Jounghee; Rao, Madhumathi; Lau, Joseph; Poe, Dennis S
2013-03-01
Sensorineural hearing loss is the third leading cause of years lived with disability worldwide. Cochlear implants may provide a viable alternative to hearing aids for this type of hearing loss. The Coverage and Analysis Group at the Centers for Medicare & Medicaid Services was interested in an evaluation of recently published literature on this topic. In addition, this meta-analysis is to our knowledge the first to evaluate quality-of-life (QOL) outcomes in adults with cochlear implants. To evaluate the communication-related outcomes and health-related QOL outcomes after unilateral or bilateral cochlear implantation in adults with sensorineural hearing loss. MEDLINE, Cochrane Central Register of Controlled Trials, Scopus, and previous reports from January 1, 2004, through May 31, 2012. Published studies of adult patients undergoing unilateral or bilateral procedures with multichannel cochlear implants and assessments using open-set sentence tests, multisyllable word tests, or QOL measures. Five researchers extracted information on population characteristics, outcomes of interest, and study design and assessed the studies for risk of bias. Discrepancies were resolved by consensus. A total of 42 studies met the inclusion criteria. Most unilateral implant studies showed a statistically significant improvement in mean speech scores as measured by open-set sentence or multisyllable word tests; meta-analysis revealed a significant improvement in QOL after unilateral implantation. Results from studies assessing bilateral implantation showed improvement in communication-related outcomes compared with unilateral implantation and additional improvements in sound localization compared with unilateral device use or implantation only. Based on a few studies, the QOL outcomes varied across tests after bilateral implantation. Unilateral cochlear implants provide improved hearing and significantly improve QOL, and improvements in sound localization are noted for bilateral implantation. Future studies of longer duration, higher-quality reporting, and large databases or registries of patients with long-term follow-up data are needed to yield stronger evidence.
Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René
2013-01-01
An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.
Cost-Utility Analysis of Cochlear Implantation in Australian Adults.
Foteff, Chris; Kennedy, Steven; Milton, Abul Hasnat; Deger, Melike; Payk, Florian; Sanderson, Georgina
2016-06-01
Sequential and simultaneous bilateral cochlear implants are emerging as appropriate treatment options for Australian adults with sensory deficits in both cochleae. Current funding of Australian public hospitals does not provide for simultaneous bilateral cochlear implantation (CI) as a separate surgical procedure. Previous cost-effectiveness studies of sequential and simultaneous bilateral CI assumed 100% of unilaterally treated patients' transition to a sequential bilateral CI. This assumption does not place cochlear implantation in the context of the generally treated population. When mutually exclusive treatment options exist, such as unilateral CI, sequential bilateral CI, and simultaneous bilateral CI, the mean costs of the treated populations are weighted in the calculation of incremental cost-utility ratios. The objective was to evaluate the cost-utility of bilateral hearing aids (HAs) compared with unilateral, sequential, and simultaneous bilateral CI in Australian adults with bilateral severe to profound sensorineural hearing loss. Cost-utility analysis of secondary sources input to a Markov model. Australian health care perspective, lifetime horizon with costs and outcomes discounted 5% annually. Bilateral HAs as treatment for bilateral severe to profound sensorineural hearing loss compared with unilateral, sequential, and simultaneous bilateral CI. Incremental costs per quality adjusted life year (AUD/QALY). When compared with bilateral hearing aids the incremental cost-utility ratio for the CI treatment population was AUD11,160/QALY. The incremental cost-utility ratio was weighted according to the number of patients treated unilaterally, sequentially, and simultaneously, as these were mutually exclusive treatment options. No peer-reviewed articles have reported the incremental analysis of cochlear implantation in a continuum of care for surgically treated populations with bilateral severe to profound sensorineural hearing loss. Unilateral, sequential, and simultaneous bilateral CI were cost-effective when compared with bilateral hearing aids. Technologies that reduce the total number of visits for a patient could introduce additional cost efficiencies into clinical practice.
Cochlear implant revision surgeries in children.
Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo
2018-02-16
The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Cullington, Helen E; Zeng, Fan-Gang
2011-02-01
Despite excellent performance in speech recognition in quiet, most cochlear implant users have great difficulty with speech recognition in noise, music perception, identifying tone of voice, and discriminating different talkers. This may be partly due to the pitch coding in cochlear implant speech processing. Most current speech processing strategies use only the envelope information; the temporal fine structure is discarded. One way to improve electric pitch perception is to use residual acoustic hearing via a hearing aid on the nonimplanted ear (bimodal hearing). This study aimed to test the hypothesis that bimodal users would perform better than bilateral cochlear implant users on tasks requiring good pitch perception. Four pitch-related tasks were used. 1. Hearing in Noise Test (HINT) sentences spoken by a male talker with a competing female, male, or child talker. 2. Montreal Battery of Evaluation of Amusia. This is a music test with six subtests examining pitch, rhythm and timing perception, and musical memory. 3. Aprosodia Battery. This has five subtests evaluating aspects of affective prosody and recognition of sarcasm. 4. Talker identification using vowels spoken by 10 different talkers (three men, three women, two boys, and two girls). Bilateral cochlear implant users were chosen as the comparison group. Thirteen bimodal and 13 bilateral adult cochlear implant users were recruited; all had good speech perception in quiet. There were no significant differences between the mean scores of the bimodal and bilateral groups on any of the tests, although the bimodal group did perform better than the bilateral group on almost all tests. Performance on the different pitch-related tasks was not correlated, meaning that if a subject performed one task well they would not necessarily perform well on another. The correlation between the bimodal users' hearing threshold levels in the aided ear and their performance on these tasks was weak. Although the bimodal cochlear implant group performed better than the bilateral group on most parts of the four pitch-related tests, the differences were not statistically significant. The lack of correlation between test results shows that the tasks used are not simply providing a measure of pitch ability. Even if the bimodal users have better pitch perception, the real-world tasks used are reflecting more diverse skills than pitch. This research adds to the existing speech perception, language, and localization studies that show no significant difference between bimodal and bilateral cochlear implant users.
López-Torrijo, Manuel; Mengual-Andrés, Santiago; Estellés-Ferrer, Remedios
2015-06-01
This article carries out a literature review of the advantages and limitations of the simultaneous bilateral cochlear implantation (SCI) compared to those of the sequential bilateral cochlear implantation (SBCI) and the unilateral cochlear implantation (UCI). The variables analysed in said comparison are: safety and surgical technique, SCI incidence, effectiveness, impact of the inter-implant interval, costs and financing, impact on brain plasticity, impact on speech and language development, main benefits, main disadvantages and concerns, and predictive factors of prognosis. Although the results are not conclusive, all variables analysed seem to point towards observable benefits of SCI in comparison with SBCI or UCI. This tendency should be studied in more depth in multicentre studies with higher methodological rigour, more comprehensive samples and periods and other determining variables (age at the time of implantation, duration and degree of the hearing loss, rehabilitation methodologies used, family involvement, etc.). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Manzoor, Nauman F; Wick, Cameron C; Wahba, Marian; Gupta, Amit; Piper, Robin; Murray, Gail S; Otteson, Todd; Megerian, Cliff A; Semaan, Maroun T
2016-02-01
To analyze audiometric outcomes after bilateral cochlear implantation in patients with isolated enlarged vestibular aqueduct (EVA) syndrome and associated incomplete partition (IP) malformations. Secondary objective was to analyze rate of cerebrospinal fluid (CSF) gusher in patients with IP-EVA spectrum deformities and compare this with the existing literature. Retrospective chart review. Thirty-two patients with EVA syndrome who received unilateral or bilateral cochlear implants between June 1999 and January 2014 were identified in the University Hospitals Case Medical Center cochlear implant database. Isolated EVA (IEVA) and Incomplete Partition Type II (IP-II) malformations were identified by reviewing high-resolution computed tomography (HRCT) imaging. Demographic information, age at implantation, surgical details, postimplantation audiometric data including speech reception thresholds (SRT), word, and sentence scores were reviewed and analyzed. Intra- and postoperative complications were analyzed as well and compared with the literature. Seventeen patients (32 implanted ears) had pediatric cochlear implantation for EVA-associated hearing loss. Data from 16 controls (32 implanted ears) were used to compare audiometric and speech outcomes of EVA cohort. Mean age at implantation was 6.8 years for EVA cohort and 6.0 years for controls. There was no statistically significant difference in long-term postoperative SRT, monaurally aided word scores, and binaurally tested word scores between pediatric EVA group and controls. The EVA patients had a long-term mean sentence score of 85.92%. A subset of EVA patients implanted at mean age of 3.18 years (n = 15 ears) had similar audiometric outcomes to another control group with Connexin 26 mutations (n = 20 ears) implanted at a similar age. Further subset analysis revealed no significant differences in age at implantation, SRT, and word scores in patients with IEVA and IP-II malformation. There was no significant association between size of vestibular aqueduct and age at implantation. There was no CSF gusher or other intra- or postoperative complications reported in our series. Bilateral sequential cochlear implantation can be performed safely in patients with EVA. Audiometric outcomes are excellent and comparable to pediatric cochlear implant patients with no malformations. CSF gusher rates can be minimized by trans-round window approach. Further long-term studies are needed to identify differences within IP-EVA spectrum deformities, audiometric outcomes, and proportions of EVA patients who will need cochlear implantation for hearing rehabilitation.
Potts, Lisa G; Skinner, Margaret W; Litovsky, Ruth A; Strube, Michael J; Kuk, Francis
2009-06-01
The use of bilateral amplification is now common clinical practice for hearing aid users but not for cochlear implant recipients. In the past, most cochlear implant recipients were implanted in one ear and wore only a monaural cochlear implant processor. There has been recent interest in benefits arising from bilateral stimulation that may be present for cochlear implant recipients. One option for bilateral stimulation is the use of a cochlear implant in one ear and a hearing aid in the opposite nonimplanted ear (bimodal hearing). This study evaluated the effect of wearing a cochlear implant in one ear and a digital hearing aid in the opposite ear on speech recognition and localization. A repeated-measures correlational study was completed. Nineteen adult Cochlear Nucleus 24 implant recipients participated in the study. The participants were fit with a Widex Senso Vita 38 hearing aid to achieve maximum audibility and comfort within their dynamic range. Soundfield thresholds, loudness growth, speech recognition, localization, and subjective questionnaires were obtained six-eight weeks after the hearing aid fitting. Testing was completed in three conditions: hearing aid only, cochlear implant only, and cochlear implant and hearing aid (bimodal). All tests were repeated four weeks after the first test session. Repeated-measures analysis of variance was used to analyze the data. Significant effects were further examined using pairwise comparison of means or in the case of continuous moderators, regression analyses. The speech-recognition and localization tasks were unique, in that a speech stimulus presented from a variety of roaming azimuths (140 degree loudspeaker array) was used. Performance in the bimodal condition was significantly better for speech recognition and localization compared to the cochlear implant-only and hearing aid-only conditions. Performance was also different between these conditions when the location (i.e., side of the loudspeaker array that presented the word) was analyzed. In the bimodal condition, the speech-recognition and localization tasks were equal regardless of which side of the loudspeaker array presented the word, while performance was significantly poorer for the monaural conditions (hearing aid only and cochlear implant only) when the words were presented on the side with no stimulation. Binaural loudness summation of 1-3 dB was seen in soundfield thresholds and loudness growth in the bimodal condition. Measures of the audibility of sound with the hearing aid, including unaided thresholds, soundfield thresholds, and the Speech Intelligibility Index, were significant moderators of speech recognition and localization. Based on the questionnaire responses, participants showed a strong preference for bimodal stimulation. These findings suggest that a well-fit digital hearing aid worn in conjunction with a cochlear implant is beneficial to speech recognition and localization. The dynamic test procedures used in this study illustrate the importance of bilateral hearing for locating, identifying, and switching attention between multiple speakers. It is recommended that unilateral cochlear implant recipients, with measurable unaided hearing thresholds, be fit with a hearing aid.
Cullington, H E; Bele, D; Brinton, J C; Cooper, S; Daft, M; Harding, J; Hatton, N; Humphries, J; Lutman, M E; Maddocks, J; Maggs, J; Millward, K; O'Donoghue, G; Patel, S; Rajput, K; Salmon, V; Sear, T; Speers, A; Wheeler, A; Wilson, K
2017-01-01
This fourteen-centre project used professional rating scales and parent questionnaires to assess longitudinal outcomes in a large non-selected population of children receiving simultaneous and sequential bilateral cochlear implants. This was an observational non-randomized service evaluation. Data were collected at four time points: before bilateral cochlear implants or before the sequential implant, one year, two years, and three years after. The measures reported are Categories of Auditory Performance II (CAPII), Speech Intelligibility Rating (SIR), Bilateral Listening Skills Profile (BLSP) and Parent Outcome Profile (POP). Thousand and one children aged from 8 months to almost 18 years were involved, although there were many missing data. In children receiving simultaneous implants after one, two, and three years respectively, median CAP scores were 4, 5, and 6; median SIR were 1, 2, and 3. Three years after receiving simultaneous bilateral cochlear implants, 61% of children were reported to understand conversation without lip-reading and 66% had intelligible speech if the listener concentrated hard. Auditory performance and speech intelligibility were significantly better in female children than males. Parents of children using sequential implants were generally positive about their child's well-being and behaviour since receiving the second device; those who were less positive about well-being changes also generally reported their children less willing to wear the second device. Data from 78% of paediatric cochlear implant centres in the United Kingdom provide a real-world picture of outcomes of children with bilateral implants in the UK. This large reference data set can be used to identify children in the lower quartile for targeted intervention.
Bilateral and unilateral cochlear implant users compared on speech perception in noise.
Dunn, Camille C; Noble, William; Tyler, Richard S; Kordus, Monika; Gantz, Bruce J; Ji, Haihong
2010-04-01
Compare speech performance in noise with matched bilateral cochlear implant (CICI) and unilateral cochlear implant (CI only) users. Thirty CICI and 30 CI-only subjects were tested on a battery of speech perception tests in noise that use an eight-loudspeaker array. On average, CICI subject's performance with speech in noise was significantly better than the CI-only subjects. The CICI group showed significantly better performance on speech perception in noise compared with the CI-only subjects, supporting the hypothesis that CICI is more beneficial than CI only.
Härkönen, Kati; Kivekäs, Ilkka; Rautiainen, Markus; Kotti, Voitto; Sivonen, Ville; Vasama, Juha-Pekka
2015-05-01
This prospective study shows that working performance, quality of life (QoL), and quality of hearing (QoH) are better with two compared with a single cochlear implant (CI). The impact of the second CI on the patient's QoL is as significant as the impact of the first CI. To evaluate the benefits of sequential bilateral cochlear implantation in working, QoL, and QoH. We studied working performance, work-related stress, QoL, and QoH with specific questionnaires in 15 patients with unilateral CI scheduled for sequential CI of another ear. Sound localization performance and speech perception in noise were measured with specific tests. All questionnaires and tests were performed before the second CI surgery and 6 and 12 months after its activation. Bilateral CIs increased patients' working performance and their work-related stress and fatigue decreased. Communication with co-workers was easier and patients were more active in their working environment. Sequential bilateral cochlear implantation improved QoL, QoH, sound localization, and speech perception in noise statistically significantly.
Using Evoked Potentials to Match Interaural Electrode Pairs with Bilateral Cochlear Implants
Delgutte, Bertrand
2007-01-01
Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency–channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable. PMID:17225976
Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants.
Smith, Zachary M; Delgutte, Bertrand
2007-03-01
Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency-channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable.
ERIC Educational Resources Information Center
Loiselle, Louise H.; Dorman, Michael F.; Yost, William A.; Cook, Sarah J.; Gifford, Rene H.
2016-01-01
Purpose: To assess the role of interaural time differences and interaural level differences in (a) sound-source localization, and (b) speech understanding in a cocktail party listening environment for listeners with bilateral cochlear implants (CIs) and for listeners with hearing-preservation CIs. Methods: Eleven bilateral listeners with MED-EL…
Current Research with Cochlear Implants at Arizona State University
Dorman, Michael F.; Spahr, Anthony; Gifford, Rene H.; Cook, Sarah; Zhang, Ting; Loiselle, Louise; Yost, William; Cardy, Lara; Whittingham, JoAnne; Schramm, David
2013-01-01
In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic listening environments, (3) accounting for the benefit provided to bimodal patients by low-frequency acoustic stimulation, (4) assessing localization by bilateral hearing aid patients and the implications of that work for hearing preservation patients, and (5) studying heart rate variability as a possible measure for quantifying the stress of listening via an implant. The long-term goals of the laboratory are to improve the performance of patients fit with cochlear implants and to understand the mechanisms, physiological or electronic, that underlie changes in performance. We began our work with cochlear implant patients in the mid-1980s and received our first grant from the National Institutes of Health (NIH) for work with implanted patients in 1989. Since that date our work with cochlear implant patients has been funded continuously by the NIH. In this report we describe some of the research currently being conducted in our laboratory. PMID:22668760
[Bilateral cochlear implants in children: acquisition of binaural hearing].
Ramos-Macías, Angel; Deive-Maggiolo, Leopoldo; Artiles-Cabrera, Ovidio; González-Aguado, Rocío; Borkoski-Barreiro, Silvia A; Masgoret-Palau, Elizabeth; Falcón-González, Juan C; Bueno-Yanes, Jorge
2013-01-01
Several studies have indicated the benefit of bilateral cochlear implants in the acquisition of binaural hearing and bilateralism. In children with cochlear implants, is it possible to achieve binaurality after a second implant? When is the ideal time to implant them? The objective of this study was to analyse the binaural effect in children with bilateral implants and the differences between subjects with simultaneous and sequential implants with both short and long intervals. There were 90 patients between 1 and 2 years of age (the first surgery), implanted between 2000 and 2008. Of these, 25 were unilateral users and 65 bilateral; 17 patients had received simultaneous implants, 29 had sequential implants before 12 months after the first one (short interimplant period) and 19 after 12 months (long period). All of them were tested for silent and noisy verbal perception and a tonal threshold audiometry was performed. The silent perception test showed that the simultaneous and short period sequential implant patients (mean: 84.67%) versus unilateral and long period sequential implants (mean: 79.66%), had a statistically-significant difference (P=0,23). Likewise, the noisy perception test showed a difference with statistical significance (P=0,22) comparing the simultaneous implanted and short period sequential implants (mean, 77.17%) versus unilateral implanted and long period sequential ones (mean: 69.32%). The simultaneous and sequential short period implants acquired the advantages of binaural hearing. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Bilateral cochlear implants in infants: a new approach--Nucleus Hybrid S12 project.
Gantz, Bruce J; Dunn, Camille C; Walker, Elizabeth A; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris
2010-10-01
The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. The study is being conducted as a repeated-measure, single-subject experiment. University of Iowa-Department of Otolaryngology. Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears. The use of a shorter-length cochlear implant on one ear and a standard-length electrode on the contralateral ear might provide a viable option for bilateral cochlear implantation in children with bilateral profound sensorineural hearing loss. Further study of this patient population will be continued.
Bilateral Cochlear Implants in Infants: A New Approach—Nucleus Hybrid S12 Project
Gantz, Bruce J.; Dunn, Camille C.; Walker, Elizabeth A.; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris
2010-01-01
Objective The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. Study Design The study is being conducted as a repeated-measure, single-subject experiment. Setting University of Iowa—Department of Otolaryngology. Patients Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Interventions Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. Main Outcome Measures The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Results Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears. Conclusion The use of a shorter-length cochlear implant on one ear and a standard-length electrode on the contralateral ear might provide a viable option for bilateral cochlear implantation in children with bilateral profound sensorineural hearing loss. Further study of this patient population will be continued. PMID:20802369
ERIC Educational Resources Information Center
Dorman, Michael F.; Natale, Sarah; Spahr, Anthony; Castioni, Erin
2017-01-01
Purpose: The aim of this experiment was to compare, for patients with cochlear implants (CIs), the improvement for speech understanding in noise provided by a monaural adaptive beamformer and for two interventions that produced bilateral input (i.e., bilateral CIs and hearing preservation [HP] surgery). Method: Speech understanding scores for…
De Raeve, Leo; Wouters, Annelies
2013-03-01
Belgium, and especially the northern region called Flanders, has been a center of expertise in cochlear implants and early hearing screening for many years. Some of their surgeons and engineers were pioneers in the development of cochlear implants and in 1998 Flanders was the first region in Europe to implement a universal hearing screening program for all neonates. The Belgian National Institute for Health and Disability Insurance has reimbursed cochlear implants in children and adults since 1994 and bilateral implantation in children under the age of 12 years since February 2010. These deaf children, screened and implanted early, achieve higher auditory, speech and language outcomes and increasing numbers are going to regular schools using fewer interpreters. In 2010, 93% of severe-to-profound deaf preschool children in Flanders had received cochlear implants and 25% had bilateral implants. Although on average twice as many adults as children are implanted a year in Belgium, we have less research data available from this adult population. Also very little is published about the growth curves and minimal rehabilitation requirements (intensity, duration etc.) after implantation for both children and adults. So, there still remain many challenges for the future.
The Self-Regulation of a Child with Cochlear Implants within a School Environment
ERIC Educational Resources Information Center
Patton, Kristin L.
2013-01-01
The purpose of this qualitative research, which utilized a narrative design strategy, was to describe the process of self-regulation of a child who has bilateral cochlear implants within the social environment of school. The study investigated the use of self-regulatory strategies by the cochlear implant recipient. It also examined how the child…
Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.
Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S
A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not observed for adults. An additional finding was that SMRT score was negatively correlated with age for adults with implants. Results from this study suggest that basic psychophysical capabilities of early implanted children and postlingually implanted adults differ when assessed in the sound field using their personal implant processors. Because spectral resolution does not improve with age for early implanted children, it seems likely that the sparse representation of the signal provided by a cochlear implant limits spectral resolution development. These results are supported by the finding that postlingually implanted adults, whose auditory systems matured before the onset of hearing loss, perform significantly better than early implanted children on the spectral resolution test.
Potts, Lisa G.; Skinner, Margaret W.; Litovsky, Ruth A.; Strube, Michael J; Kuk, Francis
2010-01-01
Background The use of bilateral amplification is now common clinical practice for hearing aid users but not for cochlear implant recipients. In the past, most cochlear implant recipients were implanted in one ear and wore only a monaural cochlear implant processor. There has been recent interest in benefits arising from bilateral stimulation that may be present for cochlear implant recipients. One option for bilateral stimulation is the use of a cochlear implant in one ear and a hearing aid in the opposite nonimplanted ear (bimodal hearing). Purpose This study evaluated the effect of wearing a cochlear implant in one ear and a digital hearing aid in the opposite ear on speech recognition and localization. Research Design A repeated-measures correlational study was completed. Study Sample Nineteen adult Cochlear Nucleus 24 implant recipients participated in the study. Intervention The participants were fit with a Widex Senso Vita 38 hearing aid to achieve maximum audibility and comfort within their dynamic range. Data Collection and Analysis Soundfield thresholds, loudness growth, speech recognition, localization, and subjective questionnaires were obtained six–eight weeks after the hearing aid fitting. Testing was completed in three conditions: hearing aid only, cochlear implant only, and cochlear implant and hearing aid (bimodal). All tests were repeated four weeks after the first test session. Repeated-measures analysis of variance was used to analyze the data. Significant effects were further examined using pairwise comparison of means or in the case of continuous moderators, regression analyses. The speech-recognition and localization tasks were unique, in that a speech stimulus presented from a variety of roaming azimuths (140 degree loudspeaker array) was used. Results Performance in the bimodal condition was significantly better for speech recognition and localization compared to the cochlear implant–only and hearing aid–only conditions. Performance was also different between these conditions when the location (i.e., side of the loudspeaker array that presented the word) was analyzed. In the bimodal condition, the speech-recognition and localization tasks were equal regardless of which side of the loudspeaker array presented the word, while performance was significantly poorer for the monaural conditions (hearing aid only and cochlear implant only) when the words were presented on the side with no stimulation. Binaural loudness summation of 1–3 dB was seen in soundfield thresholds and loudness growth in the bimodal condition. Measures of the audibility of sound with the hearing aid, including unaided thresholds, soundfield thresholds, and the Speech Intelligibility Index, were significant moderators of speech recognition and localization. Based on the questionnaire responses, participants showed a strong preference for bimodal stimulation. Conclusions These findings suggest that a well-fit digital hearing aid worn in conjunction with a cochlear implant is beneficial to speech recognition and localization. The dynamic test procedures used in this study illustrate the importance of bilateral hearing for locating, identifying, and switching attention between multiple speakers. It is recommended that unilateral cochlear implant recipients, with measurable unaided hearing thresholds, be fit with a hearing aid. PMID:19594084
Auditory plasticity in deaf children with bilateral cochlear implants
NASA Astrophysics Data System (ADS)
Litovsky, Ruth
2005-04-01
Human children with cochlear implants represent a unique population of individuals who have undergone variable amounts of auditory deprivation prior to being able to hear. Even more unique are children who received bilateral cochlear implants (BICIs), in sequential surgical procedures, several years apart. Auditory deprivation in these individuals consists of a two-stage process, whereby complete deafness is experienced initially, followed by deafness in one ear. We studied the effects of post-implant experience on the ability of deaf children to localize sounds and to understand speech in noise. These are two of the most important functions that are known to depend on binaural hearing. Children were tested at time intervals ranging from 3-months to 24-months following implantation of the second ear, while listening with either implant alone or bilaterally. Our findings suggest that the period during which plasticity occurs in human binaural system is protracted, extending into middle-to-late childhood. The rate at which benefits from bilateral hearing abilities are attained following deprivation is faster for speech intelligibility in noise compared with sound localization. Finally, the age at which the second implant was received may play an important role in the acquisition of binaural abilities. [Work supported by NIH-NIDCD.
[Bilateral cochlear implants].
Müller, J
2017-07-01
Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.
ERIC Educational Resources Information Center
Bartov, Tamar; Most, Tova
2014-01-01
Purpose: To examine song identification by preschoolers with normal hearing (NH) versus preschoolers with cochlear implants (CIs). Method: Participants included 45 children ages 3;8-7;3 (years;months): 12 with NH and 33 with CIs, including 10 with unilateral CI, 14 with bilateral CIs, and 9 bimodal users (CI-HA) with unilateral CI and…
ERIC Educational Resources Information Center
Sarant, Julia Z.; Harris, David C.; Bennet, Lisa A.
2015-01-01
Purpose: This study sought to (a) determine whether academic outcomes for children who received early cochlear implants (CIs) are age appropriate, (b) determine whether bilateral CI use significantly improves academic outcomes, and (c) identify other factors that are predictive of these outcomes. Method: Forty-four 8-year-old children with…
ERIC Educational Resources Information Center
Davis, Timothy J.; Gifford, René H.
2018-01-01
Purpose: The primary purpose of this study was to derive spatial release from masking (SRM) performance-azimuth functions for bilateral cochlear implant (CI) users to provide a thorough description of SRM as a function of target/distracter spatial configuration. The secondary purpose of this study was to investigate the effect of the microphone…
The cochlear implant as a tinnitus treatment.
Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio
2013-01-01
Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Papsin, Blake C.; Paludetti, Gaetano; Gordon, Karen A.
2015-01-01
Children using unilateral cochlear implants abnormally rely on tempo rather than mode cues to distinguish whether a musical piece is happy or sad. This led us to question how this judgment is affected by the type of experience in early auditory development. We hypothesized that judgments of the emotional content of music would vary by the type and duration of access to sound in early life due to deafness, altered perception of musical cues through new ways of using auditory prostheses bilaterally, and formal music training during childhood. Seventy-five participants completed the Montreal Emotion Identification Test. Thirty-three had normal hearing (aged 6.6 to 40.0 years) and 42 children had hearing loss and used bilateral auditory prostheses (31 bilaterally implanted and 11 unilaterally implanted with contralateral hearing aid use). Reaction time and accuracy were measured. Accurate judgment of emotion in music was achieved across ages and musical experience. Musical training accentuated the reliance on mode cues which developed with age in the normal hearing group. Degrading pitch cues through cochlear implant-mediated hearing induced greater reliance on tempo cues, but mode cues grew in salience when at least partial acoustic information was available through some residual hearing in the contralateral ear. Finally, when pitch cues were experimentally distorted to represent cochlear implant hearing, individuals with normal hearing (including those with musical training) switched to an abnormal dependence on tempo cues. The data indicate that, in a western culture, access to acoustic hearing in early life promotes a preference for mode rather than tempo cues which is enhanced by musical training. The challenge to these preferred strategies during cochlear implant hearing (simulated and real), regardless of musical training, suggests that access to pitch cues for children with hearing loss must be improved by preservation of residual hearing and improvements in cochlear implant technology. PMID:26317976
Giannantonio, Sara; Polonenko, Melissa J; Papsin, Blake C; Paludetti, Gaetano; Gordon, Karen A
2015-01-01
Children using unilateral cochlear implants abnormally rely on tempo rather than mode cues to distinguish whether a musical piece is happy or sad. This led us to question how this judgment is affected by the type of experience in early auditory development. We hypothesized that judgments of the emotional content of music would vary by the type and duration of access to sound in early life due to deafness, altered perception of musical cues through new ways of using auditory prostheses bilaterally, and formal music training during childhood. Seventy-five participants completed the Montreal Emotion Identification Test. Thirty-three had normal hearing (aged 6.6 to 40.0 years) and 42 children had hearing loss and used bilateral auditory prostheses (31 bilaterally implanted and 11 unilaterally implanted with contralateral hearing aid use). Reaction time and accuracy were measured. Accurate judgment of emotion in music was achieved across ages and musical experience. Musical training accentuated the reliance on mode cues which developed with age in the normal hearing group. Degrading pitch cues through cochlear implant-mediated hearing induced greater reliance on tempo cues, but mode cues grew in salience when at least partial acoustic information was available through some residual hearing in the contralateral ear. Finally, when pitch cues were experimentally distorted to represent cochlear implant hearing, individuals with normal hearing (including those with musical training) switched to an abnormal dependence on tempo cues. The data indicate that, in a western culture, access to acoustic hearing in early life promotes a preference for mode rather than tempo cues which is enhanced by musical training. The challenge to these preferred strategies during cochlear implant hearing (simulated and real), regardless of musical training, suggests that access to pitch cues for children with hearing loss must be improved by preservation of residual hearing and improvements in cochlear implant technology.
Yoon, Yang-soo; Li, Yongxin; Kang, Hou-Yong; Fu, Qian-Jie
2011-01-01
Objective The full benefit of bilateral cochlear implants may depend on the unilateral performance with each device, the speech materials, processing ability of the user, and/or the listening environment. In this study, bilateral and unilateral speech performances were evaluated in terms of recognition of phonemes and sentences presented in quiet or in noise. Design Speech recognition was measured for unilateral left, unilateral right, and bilateral listening conditions; speech and noise were presented at 0° azimuth. The “binaural benefit” was defined as the difference between bilateral performance and unilateral performance with the better ear. Study Sample 9 adults with bilateral cochlear implants participated. Results On average, results showed a greater binaural benefit in noise than in quiet for all speech tests. More importantly, the binaural benefit was greater when unilateral performance was similar across ears. As the difference in unilateral performance between ears increased, the binaural advantage decreased; this functional relationship was observed across the different speech materials and noise levels even though there was substantial intra- and inter-subject variability. Conclusions The results indicate that subjects who show symmetry in speech recognition performance between implanted ears in general show a large binaural benefit. PMID:21696329
Boisvert, Isabelle; McMahon, Catherine M.; Dowell, Richard C.; Lyxell, Björn
2015-01-01
In many countries, a single cochlear implant is offered as a treatment for a bilateral hearing loss. In cases where there is asymmetry in the amount of sound deprivation between the ears, there is a dilemma in choosing which ear should be implanted. In many clinics, the choice of ear has been guided by an assumption that the reorganisation of the auditory pathways caused by longer duration of deafness in one ear is associated with poorer implantation outcomes for that ear. This assumption, however, is mainly derived from studies of early childhood deafness. This study compared outcomes following implantation of the better or poorer ear in cases of long-term hearing asymmetries. Audiological records of 146 adults with bilateral hearing loss using a single hearing aid were reviewed. The unaided ear had 15 to 72 years of unaided severe to profound hearing loss before unilateral cochlear implantation. 98 received the implant in their long-term sound-deprived ear. A multiple regression analysis was conducted to assess the relative contribution of potential predictors to speech recognition performance after implantation. Duration of bilateral significant hearing loss and the presence of a prelingual hearing loss explained the majority of variance in speech recognition performance following cochlear implantation. For participants with postlingual hearing loss, similar outcomes were obtained by implanting either ear. With prelingual hearing loss, poorer outcomes were obtained when implanting the long-term sound-deprived ear, but the duration of the sound deprivation in the implanted ear did not reliably predict outcomes. Contrary to an apparent clinical consensus, duration of sound deprivation in one ear has limited value in predicting speech recognition outcomes of cochlear implantation in that ear. Outcomes of cochlear implantation are more closely related to the period of time for which the brain is deprived of auditory stimulation from both ears. PMID:26043227
Guerra-Jiménez, Gloria; Viera Artiles, Jaime; Mateos, Mar; González Aguado, Rocío; Falcón González, Juan Carlos; Borkoski Barreiro, Silvia; Ramos Macías, Angel
2013-01-01
Some studies suggest that simultaneous or sequential cochlear implantation in a short period of time offers additional benefits. There is controversy regarding the existence of an age limit after which a second implantation offers less benefit for the acquisition of communication skills. The objectives of this study were to confirm that sequential cochlear implantation offers benefits compared to unilateral implantation and to study whether, at 12 years of age, there are significant differences regarding the age at the time of the second implantation. Descriptive and observational study of a population of 12-year-old children carrying cochlear implants (n=69). A liminal pure tone audiometry and an open-field verbal discrimination test (disyllables, common phrases in an open context, with and without noise) were conducted to evaluate audiological benefits. Verbal discrimination results were better among patients who had been implanted before the age of 2 years, although the differences were not statistically significant (P>.5). Children who had received bilateral cochlear implants before the age of 2 years and with a period less than 4 years between both implants presented better verbal discrimination percentages (P<.05). In our sample, early cochlear implantation with a short period between both implants provided significant benefits regarding intelligibility. There seem to be a specific age and interimplant period, after which the auditory benefit on the first implant becomes reduced. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Härkönen, Kati; Kivekäs, Ilkka; Kotti, Voitto; Sivonen, Ville; Vasama, Juha-Pekka
2017-10-01
The objective of the present study is to evaluate the effect of hybrid cochlear implantation (hCI) on quality of life (QoL), quality of hearing (QoH), and working performance in adult patients, and to compare the long-term results of patients with hCI to those of patients with conventional unilateral cochlear implantation (CI), bilateral CI, and single-sided deafness (SSD) with CI. Sound localization accuracy and speech-in-noise test were also compared between these groups. Eight patients with high-frequency sensorineural hearing loss of unknown etiology were selected in the study. Patients with hCI had better long-term speech perception in noise than uni- or bilateral CI patients, but the difference was not statistically significant. The sound localization accuracy was equal in the hCI, bilateral CI, and SSD patients. QoH was statistically significantly better in bilateral CI patients than in the others. In hCI patients, residual hearing was preserved in all patients after the surgery. During the 3.6-year follow-up, the mean hearing threshold at 125-500 Hz decreased on average by 15 dB HL in the implanted ear. QoL and working performance improved significantly in all CI patients. Hearing outcomes with hCI are comparable to the results of bilateral CI or CI with SSD, but hearing in noise and sound localization are statistically significantly better than with unilateral CI. Interestingly, the impact of CI on QoL, QoH, and working performance was similar in all groups.
Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego
2014-03-01
To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.
Sparreboom, Marloes; Beynon, Andy J; Snik, Ad F M; Mylanus, Emmanuel A M
2016-07-01
In many studies evaluating the effect of sequential bilateral cochlear implantation in congenitally deaf children, device use is not taken into account. In this study, however, device use was analyzed in relation to auditory brainstem maturation and speech recognition, which were measured in children with early-onset deafness, 5-6 years after bilateral cochlear implantation. We hypothesized that auditory brainstem maturation is mostly functionally driven by auditory stimulation and is therefore influenced by device use and not mainly by inter-implant delay. Twenty-one children participated and had inter-implant delays between 1.2 and 7.2 years. The electrically-evoked auditory brainstem response was measured for both implants separately. The difference in interaural wave V latency and speech recognition between both implants were used in the analyses. Device use was measured with a Likert scale. Results showed that the less the second device is used, the larger the difference in interaural wave V latencies is, which consequently leads to larger differences in interaural speech recognition. In children with early-onset deafness, after various periods of unilateral deprivation, full-time device use can lead to similar auditory brainstem responses and speech recognition between both ears. Therefore, device use should be considered as a relevant factor contributing to outcomes after sequential bilateral cochlear implantation. These results are indicative for a longer window between implantations in children with early-onset deafness to obtain symmetrical auditory pathway maturation than is mentioned in the literature. Results, however, must be interpreted as preliminary findings as actual device use with data logging was not yet available at the time of the study. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Van Zanten, Gijsbert A; Grolman, Wilko; Stegeman, Inge
2017-01-01
There are many methods for assessing hearing performance after cochlear implantation. Standard evaluations often encompass objective hearing tests only, while patients' subjective experiences gain importance in today's healthcare. The aim of the current study was to analyze the correlation between subjective (self-reported questionnaires) and objective (speech perception and localization) hearing test results in adult cochlear implant (CI) users. Secondary, the correlation between subjective and objective hearing tests was compared between bilateral and unilateral CI patients. Data for this study were prospectively collected as part of a multicentre randomized controlled trial. Thirty-eight postlingually deafened adult patients were randomly allocated to receive either unilateral ( n = 19) or bilateral ( n = 19) cochlear implantation. We used data gathered after one year of follow-up. We studied the correlation between objectively measured speech perception and localization skills on the one hand and related domains of the Speech, Spatial and Qualities of Hearing Scale (SSQ) and Nijmegen Cochlear Implant Questionnaire (NCIQ) on the other hand. We also compared these correlations between unilateral and bilateral CI users. We found significant weak to moderate negative correlations between the subjective test results (speech domain of the SSQ and the advanced speech perception domain of the NCIQ) and the related objective speech perception in noise test results ( r = -0.33 to -0.48). A significant moderate correlation was found between the subjective test results (spatial domain of the SSQ) and the related objective localization test results ( r = 0.59). The correlations in the group of bilateral CI patients ( r = -0.28 to -0.54) did not differ significantly from the correlations in the group of unilateral CI patients ( r = 0.15 to -0.40). Current objective tests do not fully reflect subjective everyday listening situations. This study elucidates the importance and necessity of questionnaires in the evaluation of cochlear implantation. Therefore, it is advised to evaluate both objective and subjective tests in CI patients on a regular basis. This trial was registered on March 11, 2009 in the Dutch Trial Register. Trial registration number: NTR1722.
Rader, T; Haerterich, M; Ernst, B P; Stöver, T; Strieth, S
2018-03-01
Persistent dizziness symptoms after cochlear implantation have an impact on quality of life. In this study, the effects of bilateral cochlear implants (CI) on quality of life as well as on subjective dizziness complaints are analyzed using questionnaires, some of which have never been applied before in these patient collectives. In this article, questionnaires for the assessment of dizziness symptoms and quality of life are introduced in order to realize quality assurance. A total of 32 patients with bilateral CI were questioned regarding dizziness symptoms and quality of life. The Nijmegen Cochlear Implant Questionnaire (NCIQ) was used. In the case of reported regular dizziness, the Vertigo Handicap Questionnaire (VHQ) and the Vertigo Symptom Scale (VSS) were also assessed. Persistent dizziness symptoms were shown in 8 of 32 patients. Quality of life was measured with the NCIQ and was improved significantly (p < 0.001) by 23.7% after the second CI. The dizziness symptoms changed slightly (VHQ -11.2%; VSS +16.4%) after the second implantation. The results show that the questionnaires are valid instruments for documenting quality of life and dizziness symptoms for quality assurance. These questionnaires may be applied as a complement or an alternative to device-based measurements of peripheral vestibular dysfunction.
Plant, Kerrie; Babic, Leanne
2016-01-01
The aim of the study was to quantify the benefit provided by having access to amplified acoustic hearing in the implanted ear for use in combination with contralateral acoustic hearing and the electrical stimulation provided by the cochlear implant. Measures of spatial and non-spatial hearing abilities were obtained to compare performance obtained with different configurations of acoustic hearing in combination with electrical stimulation. In the combined listening condition participants had access to bilateral acoustic hearing whereas the bimodal condition used acoustic hearing contralateral to the implanted ear only. Experience was provided with each of the listening conditions using a repeated-measures A-B-B-A experimental design. Sixteen post-linguistically hearing-impaired adults participated in the study. Group mean benefit was obtained with use of the combined mode on measures of speech recognition in coincident speech in noise, localization ability, subjective ratings of real-world benefit, and musical sound quality ratings. Access to bilateral acoustic hearing after cochlear implantation provides significant benefit on a range of functional measures.
Eapen, Rose J.; Buss, Emily; Adunka, Marcia Clark; Pillsbury, Harold C.; Buchman, Craig A.
2012-01-01
Objective The purpose of this 4-year longitudinal study was to assess the stability of the binaural benefits of head shadow, summation, and squelch for bilateral cochlear implant recipients and to quantify these benefits for the understanding of speech in noise. Design This is a prospective study of 9 patients who received simultaneous bilateral insertion of MED-EL COMBI +40 cochlear implants in a single-stage operation at the University of North Carolina, Chapel Hill, NC. Each patient had postlingual deafness of short duration before insertion of the device. Each year, the patients were tested for word recognition using consonant-nucleus-consonant words in quiet and speech perception in noise using City University of New York sentences. These tests were administered using direct audio input to the implants. Head-related transfer functions were used to simulate speech in noise testing in a spatial environment. Speech was always presented at midline (0), and the noise masker was presented at either side or midline (−90, 0, +90 degrees). Results The binaural benefits of head shadow and summation effects developed early in the postoperative period and remained stable throughout the follow-up period. Squelch developed more slowly and was first demonstrated at 12 months after implantation but continued to increase beyond the first year of follow-up. Conclusion Benefits of head shadow and summation emerge early and remain stable. However, squelch has the most protracted period of development, with increasing benefit after a year or more of implant experience. These data support the idea that binaural integration continues several years after insertion of bilateral cochlear implant devices. PMID:19180675
[Cochlear implant in children: rational, indications and cost/efficacy].
Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S
2013-06-01
A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long this advantage persists in the subsequent years. With regard to cochlear implantation in children older than 12 months the studies show better hearing and linguistic results in children implanted at earlier ages. A sensitive period under 24-36 months has been identified over which cochlear implantation is reported to be less effective in terms of improvement in speech and hearing results. With regard to clinical effectiveness of bilateral cochlear implantation, greater benefits from bilateral implants compared to monolateral ones when assessing hearing in quiet and in noise and in sound localization abilities are reported to be present in both case of simultaneous or sequential bilateral implantation. However, with regard to the delay between the surgeries in sequential bilateral implantation, although benefit is reported to be present even after very long delays, on average long delays between surgeries seems to negatively affect the outcome with the second implant. With regard to benefits after cochlear implantation in children with multiple disabilities, benefits in terms of speech perception and communication as well as in quality of the daily life are reported even if benefits are slower and lower in comparison to those generally attained by implanted children without additional disabilities. Regarding the costs/efficacy ratio, the CI is expensive, in particular because of the cost of the high technological device, long life support, but even if healthcare costs are high, the savings in terms of indirect costs and quality of life are important. The CI, in fact, has a positive impact in terms of quality of life.
ERIC Educational Resources Information Center
Guo, Ling-Yu; McGregor, Karla K.; Spencer, Linda J.
2015-01-01
Purpose: The purpose of this study was to determine whether children with cochlear implants (CIs) are sensitive to statistical characteristics of words in the ambient spoken language, whether that sensitivity changes in expected ways as their spoken lexicon grows, and whether that sensitivity varies with unilateral or bilateral implantation.…
Peters, B Robert; Litovsky, Ruth; Parkinson, Aaron; Lake, Jennifer
2007-08-01
Clinical trials in which children received bilateral cochlear implants in sequential operations were conducted to analyze the extent to which bilateral implantation offers benefits on a number of measures. The present investigation was particularly focused on measuring the effects of age at implantation and experience after activation of the second implant on speech perception performance. Thirty children aged 3 to 13 years were recipients of 2 cochlear implants, received in sequential operations, a minimum of 6 months apart. All children received their first implant before 5 years of age and had acquired speech perception capabilities with the first device. They were divided into 3 age groups on the basis of age at time of second ear implantation: Group I, 3 to 5 years; Group II, 5.1 to 8 years; and Group III, 8.1 to 13 years. Speech perception measures in quiet included the Multisyllabic Lexical Neighborhood Test (MLNT) for Group I, the Lexical Neighborhood Test (LNT) for Groups II and III, and the Hearing In Noise Test for Children (HINT-C) sentences in quiet for Group III. Speech perception in noise was assessed using the Children's Realistic Intelligibility and Speech Perception (CRISP) test. Testing was performed preoperatively and again postactivation of the second implant at 3, 6, and 12 months (CRISP at 3 and 9 mo) in both the unilateral and bilateral conditions in a repeated-measures study design. Two-way repeated-measures analysis of variance was used to analyze statistical significance among device configurations and performance over time. US Multicenter. Results for speech perception in quiet show that children implanted sequentially acquire open-set speech perception in the second ear relatively quickly (within 6 mo). However, children younger than 8 years do so more rapidly and to a higher level of speech perception ability at 12 months than older children (mean second ear MLNT/LNT scores at 12 months: Group I, 83.9%; range, 71-96%; Group II, 59.5%; range, 40-88%; Group III, 32%; range, 12-56%). The second-ear mean HINT-C score for Group III children remained far less than that of the first ear even after 12 months of device use (44 versus 89%; t, 6.48; p<0.001; critical value, 0.025). Speech intelligibility for spondees in noise was significantly better under bilateral conditions than with either ear alone when all children were analyzed as a single group and for Group III children. At the 9-month test interval, performance in the bilateral configuration was significantly better for all noise conditions (13.2% better for noise at first cochlear implant, 6.8% better for the noise front and noise at second cochlear implant conditions, t=2.32, p=0.024, critical level=0.05 for noise front; t=3.75, p<0.0001, critical level=0.05 for noise at first implant; t=2.73, p = 0.008, critical level=0.05 for noise at second implant side). The bilateral benefit in noise increased with time from 3 to 9 months after activation of the second implant. This bilateral advantage is greatest when noise is directed toward the first implanted ear, indicating that the head shadow effect is the most effective binaural mechanism. The bilateral condition produced small improvements in speech perception in quiet and for individual Group I and Group II patient results in noise that, in view of the relatively small number of subjects tested, do not reach statistical significance. Sequential bilateral cochlear implantation in children of diverse ages has the potential to improve speech perception abilities in the second implanted ear and to provide access to the use of binaural mechanisms such as the head shadow effect. The improvement unfolds over time and continues to grow during the 6 to 12 months after activation of the second implant. Younger children in this study achieved higher open-set speech perception scores in the second ear, but older children still demonstrate bilateral benefit in noise. Determining the long-term impact and cost-effectiveness that results from such potential capabilities in bilaterally implanted children requires additional study with larger groups of subjects and more prolonged monitoring.
Cochlear implantation in patients with bilateral cochlear trauma.
Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar
2010-01-01
Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.
Teissier, N; Doehring, I; Noel-Petroff, N; Elmaleh-Bergès, M; Viala, P; François, M; Faye, A; Van Den Abbeele, T; Lorrot, M
2013-06-01
Bacterial meningitis (BM) is the primary etiology of acquired sensorineural hearing loss (SNHL) in children and may compromise language development. Since the 1990 s, cochlear implants (CIs) have become part of the management of children with profound SNHL with encouraging results. The aim of this study was to analyze the audiophonological performance of children before and after cochlear implantation for SNHL following bacterial meningitis. Retrospective study of all children fitted with CIs for bilateral severe to profound SNHL after bacterial meningitis in the Robert-Debré pediatric ENT department between August 1990 and March 2009. Audiophonological performance was assessed using the APCEI profile. Of the 283 children receiving implants during that period, 16 children (6%; 6 boys, 10 girls) underwent CI implantation after bacterial meningitis (Streptococcus pneumoniae in 8 cases, Neisseria meningitidis in 2 cases, and Haemophilus influenzae in 4 cases). The mean time from meningitis to SNHL was 8.3 months (median, 1.5 months; range, 1 day to 13 years). The mean time from meningitis to cochlear implantation was 2 years and 3 months (median, 7 months; range, 1 month to 13 years 3 months). Twelve children (75%) presented partial cochlear and/or vestibular ossification on presurgical CT scan. Three children received bilateral implants. Thirteen children (81%) developed early SNHL in the first 3 months, whereas 3 children developed SNHL more than 10 months after meningitis. As for the benefits of cochlear implantation, 11 children presented near to normal intelligibility and optimal use of their cochlear implant; 5 children presented partial benefits due to neurological sequelae (1), a long delay before implantation (1), technical problems (2), or a social problem in relation to low socioeconomic status (1). After bacterial meningitis, audiological evaluation must be made carefully during the first 3 months to detect early SNHL, but SNHL may also develop several years later. In case of profound SNHL and a modified signal of the labyrinth on the MRI, cochlear implantation must be performed without delay before cochlear and/or vestibular ossification. Cochlear implantation is an effective technique with good long-term audiologic results. The coexistence of neurological lesions may compromise the results, but it should not contraindicate a cochlear implantation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Should children who use cochlear implants wear hearing aids in the opposite ear?
Ching, T Y; Psarros, C; Hill, M; Dillon, H; Incerti, P
2001-10-01
The aim of this study was to investigate 1) whether a hearing aid needs to be adjusted differently depending on whether a child wears a cochlear implant or another hearing aid in the contralateral ear; 2) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural interference; and 3) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural benefits in speech perception, localization, and communicative functioning in real life. Sixteen children participated in this study. All children used a Nucleus 22 or Nucleus 24 cochlear implant system programmed with the SPEAK strategy in one ear. The hearing aid amplification requirements in the nonimplanted ear of these children were determined using two procedures. A paired comparison technique was used to identify the frequency response that was best for speech intelligibility in quiet, and a loudness balancing technique was used to match the loudness of speech in the ear with a hearing aid to that with a cochlear implant. Eleven of the 16 children participated in the investigation of binaural effects. Performance in speech perception, localization, and communicative functioning was assessed under four aided conditions: cochlear implant with hearing aid as worn, cochlear implant alone, hearing aid alone, and cochlear implant with hearing aid adjusted according to individual requirements. Fifteen of the 16 children whose amplification requirements were determined preferred a hearing aid frequency response that was within +/-6 dB/octave of the NAL-RP prescription. On average, the children required 6 dB more gain than prescribed to balance the loudness of the implanted ear for a speech signal presented at 65 dB SPL. For all 11 children whose performance was evaluated for investigating binaural effects, there was no indication of significantly poorer performance under bilaterally aided conditions compared with unilaterally aided conditions. On average, there were significant benefits in speech perception, localization, and aural/oral function when the children used cochlear implants with adjusted hearing aids than when they used cochlear implants alone. All individuals showed benefits in at least one of the measures. Hearing aids for children who also use cochlear implants can be selected using the NAL-RP prescription. Adjustment of hearing aid gain to match loudness in the implanted ear can facilitate integration of signals from both ears, leading to better speech perception. Given that there are binaural advantages from using cochlear implants with hearing aids in opposite ears, clinicians should advise parents and other professionals about these potential advantages, and facilitate bilateral amplification by adjusting hearing aids after stable cochlear implant MAPs are established.
Müller, Joachim
2005-01-01
Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field. The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies. The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits. PMID:22073052
Müller, Joachim
2005-01-01
Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field.The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies.The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits.
[Cochlear implantation through the middle fossa approach].
Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M
2001-01-01
The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.
Retrofacial approach to access the round window for cochlear implantation of malformed ears.
Rizk, Habib; O'Connell, Brendan; Stevens, Shawn; Meyer, Ted
2015-03-01
To report the use of the retrofacial approach for cochlear implantation in three cases of malformed ears with inaccessible round windows through the standard facial recess. Two children with bilateral profound sensorineural hearing loss who were cochlear implant candidates. One patient had bilateral sequential cochlear implantations and the other a unilateral implant. Retrofacial approach to access the posterior mesotympanum and visualize the round window. Ability to complete the surgery with full insertion of the implant and no complications such as facial nerve injury. We implanted three ears in two patients with multiple external and middle ear malformations with an aberrant facial nerve or a posteriorly displaced round window niche. The standard facial recess approach did not allow visualization of the round window. We resorted to a retrofacial approach to access the posterior mesotympanum and proceeded with the surgery through an anterior and inferior cochleostomy or through the round window. In cases with an aberrant facial nerve or inaccessible round window through the facial recess, the retrofacial approach is a good alternative but requires a certain level of expertise and familiarity with temporal bone anatomy. The decision to use an unconventional approach should be considered before surgery, but the ultimate decision may require intraoperative assessment.
Maglione, A G; Scorpecci, A; Malerba, P; Marsella, P; Giannantonio, S; Colosimo, A; Babiloni, F; Vecchiato, G
2015-01-01
The aim of the present study is to investigate the variations of the electroencephalographic (EEG) alpha rhythm in order to measure the appreciation of bilateral and unilateral young cochlear implant users during the observation of a musical cartoon. The cartoon has been modified for the generation of three experimental conditions: one with the original audio, another one with a distorted sound and, finally, a mute version. The EEG data have been recorded during the observation of the cartoons in the three experimental conditions. The frontal alpha EEG imbalance has been calculated as a measure of motivation and pleasantness to be compared across experimental populations and conditions. The EEG frontal imbalance of the alpha rhythm showed significant variations during the perception of the different cartoons. In particular, the pattern of activation of normal-hearing children is very similar to the one elicited by the bilateral implanted patients. On the other hand, results related to the unilateral subjects do not present significant variations of the imbalance index across the three cartoons. The presented results suggest that the unilateral patients could not appreciate the difference in the audio format as well as bilaterally implanted and normal hearing subjects. The frontal alpha EEG imbalance is a useful tool to detect the differences in the appreciation of audiovisual stimuli in cochlear implant patients.
The development of the Nucleus Freedom Cochlear implant system.
Patrick, James F; Busby, Peter A; Gibson, Peter J
2006-12-01
Cochlear Limited (Cochlear) released the fourth-generation cochlear implant system, Nucleus Freedom, in 2005. Freedom is based on 25 years of experience in cochlear implant research and development and incorporates advances in medicine, implantable materials, electronic technology, and sound coding. This article presents the development of Cochlear's implant systems, with an overview of the first 3 generations, and details of the Freedom system: the CI24RE receiver-stimulator, the Contour Advance electrode, the modular Freedom processor, the available speech coding strategies, the input processing options of Smart Sound to improve the signal before coding as electrical signals, and the programming software. Preliminary results from multicenter studies with the Freedom system are reported, demonstrating better levels of performance compared with the previous systems. The final section presents the most recent implant reliability data, with the early findings at 18 months showing improved reliability of the Freedom implant compared with the earlier Nucleus 3 System. Also reported are some of the findings of Cochlear's collaborative research programs to improve recipient outcomes. Included are studies showing the benefits from bilateral implants, electroacoustic stimulation using an ipsilateral and/or contralateral hearing aid, advanced speech coding, and streamlined speech processor programming.
Central masking with bilateral cochlear implants
Lin, Payton; Lu, Thomas; Zeng, Fan-Gang
2013-01-01
Across bilateral cochlear implants, contralateral threshold shift has been investigated as a function of electrode difference between the masking and probe electrodes. For contralateral electric masking, maximum threshold elevations occurred when the position of the masker and probe electrode was approximately place-matched across ears. The amount of masking diminished with increasing masker-probe electrode separation. Place-dependent masking occurred in both sequentially implanted ears, and was not affected by the masker intensity or the time delay from the masker onset. When compared to previous contralateral masking results in normal hearing, the similarities between place-dependent central masking patterns suggest comparable mechanisms of overlapping excitation in the central auditory nervous system. PMID:23363113
Discrimination of intonation contours by adolescents with cochlear implants.
Holt, Colleen M; McDermott, Hugh J
2013-12-01
Differences in fundamental frequency (F0) contour peak alignment contribute to the perception of pitch accents in speech intonation. The present study assessed the discrimination of differences in F0 contour peak alignment by adolescent users of cochlear implants (CIs). In Experiment 1, subjects discriminated between rise-fall F0 contours located early in the syllable and those aligned late. Recorded utterances with manipulated F0 were used as stimuli and all subjects wore a unilateral CI. In Experiment 2, bilaterally-implanted subjects repeated Experiment 1 in the bilateral condition. Twenty-one CI users aged 12-21 years participated. A normally-hearing control group (n = 20) also completed Experiment 1. Listeners with normal hearing (NH) could discriminate between F0 peaks differing by 80 ms or more. Results varied among the CI users, with only four users displaying a pattern of results similar to that of the NH listeners. Sixteen CI users responded inconsistently or at chance levels (p > 0.05; binomial test). Ten CI users who were bilaterally implanted completed the tests in unilateral and bilateral listening conditions. Results suggest that CI users may have difficulty discriminating between F0 alignment and that use of bilateral implants did not provide an advantage to discrimination.
Rana, Baljeet; Buchholz, Jörg M; Morgan, Catherine; Sharma, Mridula; Weller, Tobias; Konganda, Shivali Appaiah; Shirai, Kyoko; Kawano, Atsushi
2017-01-01
Binaural hearing helps normal-hearing listeners localize sound sources and understand speech in noise. However, it is not fully understood how far this is the case for bilateral cochlear implant (CI) users. To determine the potential benefits of bilateral over unilateral CIs, speech comprehension thresholds (SCTs) were measured in seven Japanese bilateral CI recipients using Helen test sentences (translated into Japanese) in a two-talker speech interferer presented from the front (co-located with the target speech), ipsilateral to the first-implanted ear (at +90° or -90°), and spatially symmetric at ±90°. Spatial release from masking was calculated as the difference between co-located and spatially separated SCTs. Localization was assessed in the horizontal plane by presenting either male or female speech or both simultaneously. All measurements were performed bilaterally and unilaterally (with the first implanted ear) inside a loudspeaker array. Both SCTs and spatial release from masking were improved with bilateral CIs, demonstrating mean bilateral benefits of 7.5 dB in spatially asymmetric and 3 dB in spatially symmetric speech mixture. Localization performance varied strongly between subjects but was clearly improved with bilateral over unilateral CIs with the mean localization error reduced by 27°. Surprisingly, adding a second talker had only a negligible effect on localization.
Cranial MRI in a young child with cochlear implants after bilateral magnet removal.
Helbig, Silke; Stöver, Timo; Burck, Iris; Kramer, Sabine
2017-12-01
A young bilateral cochlear implant (CI) user required magnetic resonance imaging (MRI) to determine the cause of hydrocephalus. The images obtained with the CIs in place were not diagnostically useful due to large artefacts generated by the CI magnets. We obtained useful images by bilaterally explanting the CI-magnets and replacing them with non-magnetic placeholder dummies then conducted the imaging. The artefact in the new images was greatly reduced and the images were diagnostically useful. Lastly, we explanted the dummies and reimplanted the CI-magnets. This procedure should be useful to obtain useful images in CI users. Copyright © 2017 Elsevier B.V. All rights reserved.
Marsella, Pasquale; Scorpecci, Alessandro; Vecchiato, Giovanni; Colosimo, Alfredo; Maglione, Anton Giulio; Babiloni, Fabio
2014-05-01
To investigate by means of non-invasive neuroelectrical imaging the differences in the perceived pleasantness of music between children with cochlear implants (CI) and normal-hearing (NH) children. 5 NH children and 5 children who received a sequential bilateral CI were assessed by means of High-Resolution EEG with Source Reconstruction as they watched a musical cartoon. Implanted children were tested before and after the second implant. For each subject the scalp Power Spectral Density was calculated in order to investigate the EEG alpha asymmetry. The scalp topographic distribution of the EEG power spectrum in the alpha band was different in children using one CI as compared to NH children (see figure). With two CIs the cortical activation pattern changed significantly, becoming more similar to the one observed in NH children. The findings support the hypothesis that bilateral CI users have a closer-to-normal perception of the pleasantness of music than unilaterally implanted children.
Cost-effectiveness of pediatric bilateral cochlear implantation in Spain.
Pérez-Martín, Jorge; Artaso, Miguel A; Díez, Francisco J
2017-12-01
To determine the incremental cost-effectiveness of bilateral versus unilateral cochlear implantation for 1-year-old children suffering from bilateral sensorineural severe to profound hearing loss from the perspective of the Spanish public health system. Cost-utility analysis. We conducted a general-population survey to estimate the quality-of-life increase contributed by the second implant. We built a Markov influence diagram and evaluated it for a life-long time horizon with a 3% discount rate in the base case. The incremental cost-effectiveness ratio of simultaneous bilateral implantation with respect to unilateral implantation for 1-year-old children with severe to profound deafness is €10,323 per quality-adjusted life year (QALY). For sequential bilateral implantation, it rises to €11,733/QALY. Both options are cost-effective for the Spanish health system, whose willingness to pay is estimated at around €30,000/QALY. The probabilistic sensitivity analysis shows that the probability of bilateral implantation being cost-effective reaches 100% for that cost-effectiveness threshold. Bilateral implantation is clearly cost-effective for the population considered. If possible, it should be done simultaneously (i.e., in one surgical operation), because it is as safe and effective as sequential implantation, and saves costs for the system and for users and their families. Sequential implantation is also cost-effective for children who have received the first implant recently, but it is difficult to determine when it ceases to be so because of the lack of detailed data. These results are specific for Spain, but the model can easily be adapted to other countries. 2C. Laryngoscope, 127:2866-2872, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
The Development of Auditory Perception in Children Following Auditory Brainstem Implantation
Colletti, Liliana; Shannon, Robert V.; Colletti, Vittorio
2014-01-01
Auditory brainstem implants (ABI) can provide useful auditory perception and language development in deaf children who are not able to use a cochlear implant (CI). We prospectively followed-up a consecutive group of 64 deaf children up to 12 years following ABI implantation. The etiology of deafness in these children was: cochlear nerve aplasia in 49, auditory neuropathy in 1, cochlear malformations in 8, bilateral cochlear post-meningitic ossification in 3, NF2 in 2, and bilateral cochlear fractures due to a head injury in 1. Thirty five children had other congenital non-auditory disabilities. Twenty two children had previous CIs with no benefit. Fifty eight children were fitted with the Cochlear 24 ABI device and six with the MedEl ABI device and all children followed the same rehabilitation program. Auditory perceptual abilities were evaluated on the Categories of Auditory Performance (CAP) scale. No child was lost to follow-up and there were no exclusions from the study. All children showed significant improvement in auditory perception with implant experience. Seven children (11%) were able to achieve the highest score on the CAP test; they were able to converse on the telephone within 3 years of implantation. Twenty children (31.3%) achieved open set speech recognition (CAP score of 5 or greater) and 30 (46.9%) achieved a CAP level of 4 or greater. Of the 29 children without non-auditory disabilities, 18 (62%) achieved a CAP score of 5 or greater with the ABI. All children showed continued improvements in auditory skills over time. The long-term results of ABI implantation reveal significant auditory benefit in most children, and open set auditory recognition in many. PMID:25377987
Rader, T
2015-02-01
Cochlear implantation with the aim of hearing preservation for combined electric-acoustic stimulation (EAS) is the therapy of choice for patients with residual low-frequency hearing. Preserved residual acoustic hearing has a positive effect on speech intelligibility in difficult noise conditions. The goal of this study was to assess speech reception thresholds in various complex noise conditions for patients with EAS in comparison with patients using bilateral cochlear implants (CI). Speech perception in noise was measured for bilateral CI and EAS patient groups. A total of 22 listeners with normal hearing served as a control group. Speech reception thresholds (SRT) were measured using a closed-set sentence matrix test. Speech was presented with a single source in frontal position; noise was presented in frontal position or in a multisource noise field (MSNF) consisting of a four-loudspeaker array with independent noise sources. Modulated speech-simulating noise and pseudocontinuous noise served respectively as interference signal with different temporal characteristics. The average SRTs in the EAS group were significantly better in all test conditions than those of the group with bilateral CI. Both user groups showed significant improvement in the MSNF condition compared with the frontal noise condition as a result of bilateral interaction. The normal-hearing control group was able to use short temporal gaps in modulated noise to improve speech perception in noise (gap listening). This effect was absent in both implanted user groups. Patients with combined EAS in one ear and a hearing aid in the contralateral ear show significantly improved speech perception in complex noise conditions compared with bilateral CI recipients.
Paediatric cochlear implantation factors that affect outcomes.
Driver, Sandra; Jiang, Dan
2017-01-01
Cochlear implantation is an established surgical intervention for individuals with bilateral severe to profound sensorineural hearing loss. The aim of the interevention is to provide the individual with a sensation of sound which they can learn to interpret with meaning. Outcomes vary considerably and the factors that impact on outcomes will be discussed. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Most, Tova; Gaon-Sivan, Gal; Shpak, Talma; Luntz, Michal
2012-01-01
Binaural hearing in cochlear implant (CI) users can be achieved either by bilateral implantation or bimodally with a contralateral hearing aid (HA). Binaural-bimodal hearing has the advantage of complementing the high-frequency electric information from the CI by low-frequency acoustic information from the HA. We examined the contribution of a…
Cochlear implantation in patient with Dandy-walker syndrome.
de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K
2012-07-01
Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.
Domville-Lewis, Chloe; Santa Maria, Peter L; Upson, Gemma; Chester-Browne, Ronel; Atlas, Marcus D
2015-01-01
The purpose of this study was to establish a statistical definition for stability in cochlear implant maps. Once defined, this study aimed to compare the duration taken to achieve a stable map in first and second implants in patients who underwent sequential bilateral cochlear implantation. This article also sought to evaluate a number of factors that potentially affect map stability. A retrospective cohort study of 33 patients with sensorineural hearing loss who received sequential bilateral cochlear implantation (Cochlear, Sydney, Australia), performed by the senior author. Psychophysical parameters of hearing threshold scores, comfort scores, and the dynamic range were measured for the apical, medial, and basal portions of the cochlear implant electrode at a range of intervals postimplantation. Stability was defined statistically as a less than 10% difference in threshold, comfort, and dynamic range scores over three consecutive mapping sessions. A senior cochlear implant audiologist, blinded to implant order and the statistical results, separately analyzed these psychophysical map parameters using current assessment methods. First and second implants were compared for duration to achieve stability, age, gender, the duration of deafness, etiology of deafness, time between the insertion of the first and second implant, and the presence or absence of preoperative hearing aids were evaluated and its relationship to stability. Statistical analysis included performing a two-tailed Student's t tests and least squares regression analysis, with a statistical significance set at p ≤ 0.05. There was a significant positive correlation between the devised statistical definition and the current audiology methods for assessing stability, with a Pearson correlation coefficient r = 0.36 and a least squares regression slope (b) of 0.41, df(58), 95% confidence interval 0.07 to 0.55 (p = 0.004). The average duration from device switch on to stability in the first implant was 87 days using current audiology methods and 81 days using the statistical definition, with no statistically significant difference between assessment methods (p = 0.2). The duration to achieve stability in the second implant was 51 days using current audiology methods and 60 days using the statistical method, and again no difference between the two assessment methods (p = 0.13). There was a significant reduction in the time to achieve stability in second implants for both audiology and statistical methods (p < 0.001 and p = 0.02, respectively). There was a difference in duration to achieve stability based on electrode array region, with basal portions taking longer to stabilize than apical in the first implant (p = 0.02) and both apical and medial segments in second implants (p = 0.004 and p = 0.01, respectively). No factors that were evaluated in this study, including gender, age, etiology of deafness, duration of deafness, time between implant insertion, and the preoperative hearing aid status, were correlated with stability duration in either stability assessment method. Our statistical definition can accurately predict cochlear implant map stability when compared with current audiology practices. Cochlear implants that are implanted second tend to stabilize sooner than the first, which has a significant impact on counseling before a second implant. No factors evaluated affected the duration required to achieve stability in this study.
Zwolan, Teresa A; O'Sullivan, Mary Beth; Fink, Nancy E; Niparko, John K
2008-02-01
To evaluate mapping characteristics of children with cochlear implants who are enrolled in the Childhood Development After Cochlear Implantation (CDACI) multicenter study. Longitudinal evaluation during 24 months of speech processor maps of children with cochlear implants prospectively enrolled in the study. Six tertiary referral centers. One hundred eighty-eight children enrolled in the CDACI study who were 5 years old or younger at the time of enrollment. Of these children, 184 received unilateral implants, and 4 received simultaneous bilateral implants. Children attended regular mapping sessions at their implant clinic as part of the study protocol. Maps were examined for each subject at 4 different time intervals: at device activation and 6, 12, and 24 months postactivation. Mean C/M levels (in charge per phase) were compared for 4 different time intervals, for 3 different devices, for 6 different implant centers, and for children with normal and abnormal cochleae. All 3 types of implant devices demonstrate significant increases in C/M levels between device activation and the 24-month appointment. Significant differences in mean C/M levels were noted between devices. Children with cochlear anomalies demonstrate significantly greater C/M levels than children with normal cochleae. The CDACI study has enabled us to evaluate the mapping characteristics of pediatric patients who use 3 different devices and were implanted at a variety of implant centers. Analysis of such data enables us to better understand the mapping characteristics of children with cochlear implants.
Buchholz, Jörg M.; Morgan, Catherine; Sharma, Mridula; Weller, Tobias; Konganda, Shivali Appaiah; Shirai, Kyoko; Kawano, Atsushi
2017-01-01
Binaural hearing helps normal-hearing listeners localize sound sources and understand speech in noise. However, it is not fully understood how far this is the case for bilateral cochlear implant (CI) users. To determine the potential benefits of bilateral over unilateral CIs, speech comprehension thresholds (SCTs) were measured in seven Japanese bilateral CI recipients using Helen test sentences (translated into Japanese) in a two-talker speech interferer presented from the front (co-located with the target speech), ipsilateral to the first-implanted ear (at +90° or −90°), and spatially symmetric at ±90°. Spatial release from masking was calculated as the difference between co-located and spatially separated SCTs. Localization was assessed in the horizontal plane by presenting either male or female speech or both simultaneously. All measurements were performed bilaterally and unilaterally (with the first implanted ear) inside a loudspeaker array. Both SCTs and spatial release from masking were improved with bilateral CIs, demonstrating mean bilateral benefits of 7.5 dB in spatially asymmetric and 3 dB in spatially symmetric speech mixture. Localization performance varied strongly between subjects but was clearly improved with bilateral over unilateral CIs with the mean localization error reduced by 27°. Surprisingly, adding a second talker had only a negligible effect on localization. PMID:28752811
Sarant, Julia; Garrard, Philippa
2014-01-01
Little attention has been focused on stress levels of parents of children with cochlear implants (CIs). This study examined the stress experience of 70 parents of children with CIs by comparing stress levels in this group of parents to those in parents of children without disabilities, identifying primary stressors, examining the relationship between parent stress and child language, and comparing stress in parents of children with bilateral and unilateral CIs. Parents completed a parent stress questionnaire, and the receptive vocabulary and language abilities of the children were evaluated. Results indicated that these parents had a higher incidence of stress than the normative population. Parent stress levels and child language outcomes were negatively correlated. Child behavior and lack of spousal and social support were the prime causes of parent stress. Parents of children with bilateral CIs were significantly less stressed than were parents of children with unilateral CIs.
ERIC Educational Resources Information Center
Dorman, Michael F.; Liss, Julie; Wang, Shuai; Berisha, Visar; Ludwig, Cimarron; Natale, Sarah Cook
2016-01-01
Purpose: Five experiments probed auditory-visual (AV) understanding of sentences by users of cochlear implants (CIs). Method: Sentence material was presented in auditory (A), visual (V), and AV test conditions to listeners with normal hearing and CI users. Results: (a) Most CI users report that most of the time, they have access to both A and V…
Binaural hearing with electrical stimulation
Kan, Alan; Litovsky, Ruth Y.
2014-01-01
Bilateral cochlear implantation is becoming a standard of care in many clinics. While much benefit has been shown through bilateral implantation, patients who have bilateral cochlear implants (CIs) still do not perform as well as normal hearing listeners in sound localization and understanding speech in noisy environments. This difference in performance can arise from a number of different factors, including the areas of hardware and engineering, surgical precision and pathology of the auditory system in deaf persons. While surgical precision and individual pathology are factors that are beyond careful control, improvements can be made in the areas of clinical practice and the engineering of binaural speech processors. These improvements should be grounded in a good understanding of the sensitivities of bilateral CI patients to the acoustic binaural cues that are important to normal hearing listeners for sound localization and speech in noise understanding. To this end, we review the current state-of-the-art in the understanding of the sensitivities of bilateral CI patients to binaural cues in electric hearing, and highlight the important issues and challenges as they relate to clinical practice and the development of new binaural processing strategies. PMID:25193553
Cochlear implantation in chronic demyelinating inflammatory polyneuropathy.
Mowry, Sarah E; King, Sarah
2017-03-01
To describe a case of chronic inflammatory demyelinating polyneuropathy (CDIP) with bilateral sudden sensorineural hearing loss who subsequently benefited from unilateral cochlear implantation. case history review and review of the literature for the terms CDIP, hearing loss, cochleovestibular dysfunction, and cochlear implantation. A 49-year-old woman presented with bilateral rapidly progressive sensorineural hearing loss (SNHL) 1 month after an upper respiratory tract infection. Hearing loss was not responsive to high-dose steroids and there were no other laboratory abnormalities or physical findings. Within 1 month, she developed ascending motor palsy, requiring long-term ventilator support. This neurologic condition was diagnosed as CDIP and she was successfully treated with plasmapheresis and intravenous immunoglobulin. Her hearing never recovered. At the time of cochlear implant, she had no response at the limits of the audiometer and obtained 0% on AzBio testing. No ABR could be recorded preoperatively. She underwent uneventful cochlear implantation with a perimodilar electrode. One year after activation, she had a PTA of 20 dB and 40% on AzBio sentence testing. Her eABR demonstrated a neuropathy pattern. Only two other cases of CDIP associated with dysfunction of the eighth nerve have been described, and neither had documented profound hearing loss. Severe SNHL associated with CDIP is rare. Although this patient has good access to sound, speech discrimination is poor at 1-year post implantation. This outcome may be due to incomplete recovery of myelination of the eighth nerve. Other possibilities include loss of peripheral nerve fibers due to the initial viral upper respiratory infection, which may lead to less neural substrate to stimulate.
Is there a best side for cochlear implants in post-lingual patients?
Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo
2017-07-29
Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Naito, Y; Okazawa, H; Honjo, I; Hirano, S; Takahashi, H; Shiomi, Y; Hoji, W; Kawano, M; Ishizu, K; Yonekura, Y
1995-07-01
Six postlingually deaf patients using multi-channel cochlear implants were examined by positron emission tomography (PET) using 15O-labeled water. Changes in regional cerebral blood flow (rCBF) were measured during different sound stimuli. The stimulation paradigms employed consisted of two sets of three different conditions; (1) no sound stimulation with the speech processor of the cochlear implant system switched off, (2) hearing white noise and (3) hearing sequential Japanese sentences. In the primary auditory area, the mean rCBF increase during noise stimulation was significantly greater on the side contralateral to the implant than on the ipsilateral side. Speech stimulation caused significantly greater rCBF increase compared with noise stimulation in the left immediate auditory association area (P < 0.01), the bilateral auditory association areas (P < 0.01), the posterior part of the bilateral inferior frontal gyri; the Broca's area (P < 0.01) and its right hemisphere homologue (P < 0.05). Activation of cortices related to verbal and non-verbal sound recognition was clearly demonstrated in the current subjects probably because complete silence was attained in the control condition.
Simultaneous versus sequential bilateral cochlear implants in adults: Cost analysis in a US setting.
Trinidade, Aaron; Page, Joshua C; Kennett, Sarah W; Cox, Matthew D; Dornhoffer, John L
2017-11-01
From a purely surgical efficiency point of view, simultaneous cochlear implantation (SimCI) is more cost-effective than sequential cochlear implantation (SeqCI) when total direct costs are considered (implant and hospital costs). However, in a setting where only SeqCI is practiced and a proportion of initially unilaterally implanted patients do not progress to a second implant, this may not be the case, especially when audiological costs are factored in. We present a cost analysis of such a scenario as would occur in our institution. Retrospective review and cost analysis. Between 2005 and 2015, 370 patients fulfilled the audiological criteria for bilateral implantation. Of those, 267 (72.1%) underwent unilateral cochlear implantation only, 101 (27.3%) progressed to SeqCI, and two underwent SimCI. The total hospital, surgical, and implant costs, and initial implant stimulation series audiological costs between August 2015 and August 2016 (29 adult patients) were used in this analysis. The total hospital, surgical, and implant costs for this period was $2,731,360.42. Based on previous local trends, if a projected eight (27.3%) of these patients decide to progress to SeqCI, this will cost an additional $750,811.04, resulting in an overall total of $3,482,171.46 for these 29 patients. Had all 29 undergone SimCI, the total projected cost would have been $3,332,991.75, representing a total potential saving of $149,179.67 (4.3%). In institutions where only SeqCI is allowed in adults, overall patient management may cost marginally more than if SimCI were practiced. This will be of interest to CI programs and health insurance companies. 4. Laryngoscope, 127:2615-2618, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Pinyon, Jeremy L; Tadros, Sherif F; Froud, Kristina E; Y Wong, Ann C; Tompson, Isabella T; Crawford, Edward N; Ko, Myungseo; Morris, Renée; Klugmann, Matthias; Housley, Gary D
2014-04-23
The cochlear implant is the most successful bionic prosthesis and has transformed the lives of people with profound hearing loss. However, the performance of the "bionic ear" is still largely constrained by the neural interface itself. Current spread inherent to broad monopolar stimulation of the spiral ganglion neuron somata obviates the intrinsic tonotopic mapping of the cochlear nerve. We show in the guinea pig that neurotrophin gene therapy integrated into the cochlear implant improves its performance by stimulating spiral ganglion neurite regeneration. We used the cochlear implant electrode array for novel "close-field" electroporation to transduce mesenchymal cells lining the cochlear perilymphatic canals with a naked complementary DNA gene construct driving expression of brain-derived neurotrophic factor (BDNF) and a green fluorescent protein (GFP) reporter. The focusing of electric fields by particular cochlear implant electrode configurations led to surprisingly efficient gene delivery to adjacent mesenchymal cells. The resulting BDNF expression stimulated regeneration of spiral ganglion neurites, which had atrophied 2 weeks after ototoxic treatment, in a bilateral sensorineural deafness model. In this model, delivery of a control GFP-only vector failed to restore neuron structure, with atrophied neurons indistinguishable from unimplanted cochleae. With BDNF therapy, the regenerated spiral ganglion neurites extended close to the cochlear implant electrodes, with localized ectopic branching. This neural remodeling enabled bipolar stimulation via the cochlear implant array, with low stimulus thresholds and expanded dynamic range of the cochlear nerve, determined via electrically evoked auditory brainstem responses. This development may broadly improve neural interfaces and extend molecular medicine applications.
Cochlear implantation in patient with Dandy-walker syndrome
de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K.
2012-01-01
Summary Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of “Dandy-Walker syndrome” for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality. PMID:25991966
Evaluation on health-related quality of life in deaf children with cochlear implant in China.
Liu, Hong; Liu, Hong-Xiang; Kang, Hou-Yong; Gu, Zheng; Hong, Su-Ling
2016-09-01
Previous studies have shown that deaf children benefit considerably from cochlear implants. These improvements are found in areas such as speech perception, speech production, and audiology-verbal performance. Despite the increasing prevalence of cochlear implants in China, few studies have reported on health-related quality of life in children with cochlear implants. The main objective of this study was to explore health-related quality of life on children with cochlear implants in South-west China. A retrospective observational study of 213 CI users in Southwest China between 2010 and 2013. Participants were 213 individuals with bilateral severe-to-profound hearing loss who wore unilateral cochlear implants. The Nijmegen Cochlear Implant Questionnaire and Health Utility Index Mark III were used pre-implantation and 1 year post-implantation. Additionally, 1-year postoperative scores for Mandarin speech perception were compared with preoperative scores. Health-related quality of life improved post-operation with scores on the Nijmegen Cochlear Implant Questionnaire improving significantly in all subdomains, and the Health Utility Index 3 showing a significant improvement in the utility score and the subdomains of ''hearing," ''speech," and "emotion". Additionally, a significant improvement in speech recognition scores was found. No significant correlation was found between increased in quality of life and speech perception scores. Health-related quality of life and speech recognition in prelingual deaf children significantly improved post-operation. The lack of correlation between quality of life and speech perception suggests that when evaluating performance post-implantation in prelingual deaf children and adolescents, measures of both speech perception and quality of life should be used. Copyright © 2016. Published by Elsevier Ireland Ltd.
The case for earlier cochlear implantation in postlingually deaf adults.
Dowell, Richard C
2016-01-01
This paper aimed to estimate the difference in speech perception outcomes that may occur due to timing of cochlear implantation in relation to the progression of hearing loss. Data from a large population-based sample of adults with acquired hearing loss using cochlear implants (CIs) was used to estimate the effects of duration of hearing loss, age, and pre-implant auditory skills on outcomes for a hypothetical standard patient. A total of 310 adults with acquired severe/profound bilateral hearing loss who received a CI in Melbourne, Australia between 1994 and 2006 provided the speech perception data and demographic information to derive regression equations for estimating CI outcomes. For a hypothetical CI candidate with progressive sensorineural hearing loss, the estimates of speech perception scores following cochlear implantation are significantly better if implantation occurs relatively soon after onset of severe hearing loss and before the loss of all functional auditory skills. Improved CI outcomes and quality of life benefit may be achieved for adults with progressive severe hearing loss if they are implanted earlier in the progression of the pathology.
The effects of early auditory-based intervention on adult bilateral cochlear implant outcomes.
Lim, Stacey R
2017-09-01
The goal of this exploratory study was to determine the types of improvement that sequentially implanted auditory-verbal and auditory-oral adults with prelingual and childhood hearing loss received in bilateral listening conditions, compared to their best unilateral listening condition. Five auditory-verbal adults and five auditory-oral adults were recruited for this study. Participants were seated in the center of a 6-loudspeaker array. BKB-SIN sentences were presented from 0° azimuth, while multi-talker babble was presented from various loudspeakers. BKB-SIN scores in bilateral and the best unilateral listening conditions were compared to determine the amount of improvement gained. As a group, the participants had improved speech understanding scores in the bilateral listening condition. Although not statistically significant, the auditory-verbal group tended to have greater speech understanding with greater levels of competing background noise, compared to the auditory-oral participants. Bilateral cochlear implantation provides individuals with prelingual and childhood hearing loss with improved speech understanding in noise. A higher emphasis on auditory development during the critical language development years may add to increased speech understanding in adulthood. However, other demographic factors such as age or device characteristics must also be considered. Although both auditory-verbal and auditory-oral approaches emphasize spoken language development, they emphasize auditory development to different degrees. This may affect cochlear implant (CI) outcomes. Further consideration should be made in future auditory research to determine whether these differences contribute to performance outcomes. Additional investigation with a larger participant pool, controlled for effects of age and CI devices and processing strategies, would be necessary to determine whether language learning approaches are associated with different levels of speech understanding performance.
Auditory Speech Perception Development in Relation to Patient's Age with Cochlear Implant
Ciscare, Grace Kelly Seixas; Mantello, Erika Barioni; Fortunato-Queiroz, Carla Aparecida Urzedo; Hyppolito, Miguel Angelo; Reis, Ana Cláudia Mirândola Barbosa dos
2017-01-01
Introduction A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1. PMID:28680487
Are hearing losses among young Maori different to those found in the young NZ European population?
Digby, Janet E; Purdy, Suzanne C; Kelly, Andrea S; Welch, David; Thorne, Peter R
2014-07-18
This study was undertaken to determine if young Maori have more permanent bilateral hearing loss, or less severe and profound hearing loss than New Zealand (NZ) Europeans. Data include hearing-impaired children from birth to 19 years of age from the New Zealand Deafness Notification Database (DND) and covering the periods 1982-2005 and 2009-2013. These were retrospectively analysed, as was information on children and young people with cochlear implants. Young Maori are more likely to be diagnosed with permanent hearing loss greater than 26 dB HL, averaged across speech frequencies, with 39-43% of hearing loss notifications listed as Maori. Maori have a lower prevalence of severe/profound losses (n=1571, chi squared=22.08, p=0.01) but significantly more bilateral losses than their NZ European peers (n=595, Chi-squared=9.05, p=0.01). The difference in severity profile is supported by cochlear implant data showing Maori are less likely to receive a cochlear implant. There are significant differences in the proportion of bilateral (compared to unilateral) losses and in the rates and severity profile of hearing loss among young Maori when compared with their NZ European peers. This has implications for screening and other hearing services in NZ.
Todd, Ann E; Goupell, Matthew J; Litovsky, Ruth Y
2016-07-01
Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs.
Lane, John I; Witte, Robert J; Driscoll, Colin L W; Shallop, Jon K; Beatty, Charles W; Primak, Andrew N
2007-08-01
To use the improved resolution available with 64-slice multidetector computed tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal turn. Sixty-four-slice MDCT examinations of the temporal bones were retrospectively reviewed in 17 patients. Twenty-three implants were evaluated. Tertiary referral facility. All patients with previous cochlear implantation evaluated at our center between January 2004 and March 2006 were offered a computed tomographic examination as part of the study. In addition, preoperative computed tomographic examinations in patients being evaluated for a second bilateral device were included. Sixty-four-slice MDCT examination of the temporal bones. Localization of the electrode array within the basal turn from multiplanar reconstructions of the cochlea. Twenty-three implants were imaged in 17 patients. We were able to localize the electrode array within the scala tympani within the basal turn in 10 implants. In 3 implants, the electrode array was localized to the scala vestibuli. Migration of the electrode array from scala tympani to scala vestibuli was observed in three implants. Of the 7 implants in which localization of the electrode array was indeterminate, all had disease entities that obscured the definition of the normal cochlear anatomy. Sixty-four-slice MDCT with multiplanar reconstructions of the postoperative cochlea after cochlear implantation allows for accurate localization of the electrode array within the basal turn where normal cochlear anatomy is not obscured by the underlying disease process. Correlating the position of the electrode in the basal turn with surgical technique and implant design could be helpful in improving outcomes.
Use of data mining to predict significant factors and benefits of bilateral cochlear implantation.
Ramos-Miguel, Angel; Perez-Zaballos, Teresa; Perez, Daniel; Falconb, Juan Carlos; Ramosb, Angel
2015-11-01
Data mining (DM) is a technique used to discover pattern and knowledge from a big amount of data. It uses artificial intelligence, automatic learning, statistics, databases, etc. In this study, DM was successfully used as a predictive tool to assess disyllabic speech test performance in bilateral implanted patients with a success rate above 90%. 60 bilateral sequentially implanted adult patients were included in the study. The DM algorithms developed found correlations between unilateral medical records and Audiological test results and bilateral performance by establishing relevant variables based on two DM techniques: the classifier and the estimation. The nearest neighbor algorithm was implemented in the first case, and the linear regression in the second. The results showed that patients with unilateral disyllabic test results below 70% benefited the most from a bilateral implantation. Finally, it was observed that its benefits decrease as the inter-implant time increases.
Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI.
Cuda, D; Murri, A; Succo, G
2013-04-01
We report a retrospective case of inner magnet migration, which occurred after 1.5 Tesla MRI scanning in an adult recipient of a bilateral cochlear implant (CI) despite a focused head dressing. The patient, bilaterally implanted with Nucleus 5 CIs (Cochlear LTD, Sydney, Australia), underwent a 1.5 Tesla cholangio-MRI scan for biliary duct pathology. In subsequent days, a focal skin alteration appeared over the left inner coil. Plain skull radiographs showed partial magnet migration on the left side. Surgical exploration confirmed magnet twisting; the magnet was effectively repositioned. Left CI performance was restored to pre-migration level. The wound healed without complications. Thus, focused dressing does not prevent magnet migration in CI recipients undergoing 1.5 Tesla MRI. All patients should be counselled on this potential complication. A minor surgical procedure is required to reposition the magnet. Nevertheless, timely diagnosis is necessary to prevent skin breakdown and subsequent device contamination. Plain skull radiograph is very effective in identifying magnet twisting; it should be performed systematically after MRI or minimally on all suspected cases.
Falcón-González, Juan C; Borkoski-Barreiro, Silvia; Limiñana-Cañal, José María; Ramos-Macías, Angel
2014-01-01
Music is a universal, cross-cultural phenomenon. Perception and enjoyment of music are still not solved with current technological objectives of cochlear implants. The objective of this article was to advance the development and validation of a method of programming of cochlear implants that implements a frequency allocation strategy. We compared standard programming vs frequency programming in every subject. We studied a total of 40 patients with cochlear implants. Each patient was programmed with a optimal version of the standard program, using the Custom Sound Suite 3.2 cochlear platform. Speech tests in quiet were performed using syllable word lists from the protocol for the assessment of hearing in the Spanish language. Patients implanted bilaterally were tested in both ears at the same time. For assessing music listening habits we used the Munich Music Questionnaire and «MACarena»(minimum auditory capability) software. All patients achieved better results in recognition, instrument tests and tonal scales with frequency programming (P<.005). Likewise, there were better results with frequency programming in recognising harmonics and pitch test (P<.005). Frequency programming achieves better perception and recognition results in patients in comparison with standard programming. Bilateral stimulation patients have better perception of musical patterns and better performance in recognition of tonal scales, harmonics and musical instruments compared with patients with unilateral stimulation. Modification and frequency allocation during programming allows decreased levels of current intensity and increase the dynamic range, which allows mapping of each audio band less obtrusively and improves the quality of representation of the signal. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Eftekharian, Ali; Mahani, Mozhgan Hosseinerezai
2015-09-01
To share our experience in cochlear implanted patients with Jervell and Lange-Nielsen syndrome (JLNS), to review the literature results and to disclose precautions which have to be taken dealing with these patients. Electrocardiograms (ECG) of 503 children with congenital bilateral profound hearing loss which were cochlear implanted in cochlear implant center of a tertiary hospital were evaluated for long QT syndrome. Clinical reports of the patients with JLNS were evaluated and a review of literature performed. The prevalence of disease was 0.79% (four cases) in our center which is in the range of literature reports (0-2.6%). None of our patients had a history of syncopal attack. Two patients (50%) were born from parents with consanguineous marriage. Considering all precautions their cochlear implant surgeries were done uneventfully. A review of the literature has identified sixteen reports on cochlear implantation in a total of 38 children with JLNS. Similar to our cases none of the authors reported cardiac events during device switch-on. Nine available reports about the outcome of cochlear implantation in these patients indicated good auditory outcome. It is recommended that all congenitally deaf patients have an ECG taken as a part of the evaluation. As auditory stimuli is reported to be a specific trigger, it is prudent to activate the processor with continuous heart monitoring even though there is no reported cardiac event during device switch-on. Cochlear implantation can be performed relatively safely in these patients if necessary precautions have been taken appropriately and their auditory outcome is good. Triggers of the cardiac events should be avoided throughout their life. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Leigh, Jaime R; Dettman, Shani J; Dowell, Richard C
2016-01-01
Establish up-to-date evidence-based guidelines for recommending cochlear implantation for young children. Speech perception results for early-implanted children were compared to children using traditional amplification. Equivalent pure-tone average (PTA) hearing loss for cochlear implant (CI) users was established. Language of early-implanted children was assessed over six years and compared to hearing peers. Seventy-eight children using CIs and 62 children using traditional amplification with hearing losses ranging 25-120 dB HL PTA (speech perception study). Thirty-two children who received a CI before 2.5 years of age (language study). Speech perception outcomes suggested that children with a PTA greater than 60 dB HL have a 75% chance of benefit over traditional amplification. More conservative criteria applied to the data suggested that children with PTA greater than 82 dB HL have a 95% chance of benefit. Children implanted under 2.5 years with no significant cognitive deficits made normal language progress but retained a delay approximately equal to their age at implantation. Hearing-impaired children under three years of age may benefit from cochlear implantation if their PTA exceeds 60 dB HL bilaterally. Implantation as young as possible should minimize any language delay resulting from an initial period of auditory deprivation.
Łukaszewicz-Moszyńska, Zuzanna; Lachowska, Magdalena; Niemczyk, Kazimierz
2014-01-01
The purpose of this study was to evaluate possible relationships between duration of cochlear implant use and results of positron emission tomography (PET) measurements in the temporal lobes performed while subjects listened to speech stimuli. Other aspects investigated were whether implantation side impacts significantly on cortical representations of functions related to understanding speech (ipsi- or contralateral to the implanted side) and whether any correlation exists between cortical activation and speech therapy results. Objective cortical responses to acoustic stimulation were measured, using PET, in nine cochlear implant patients (age range: 15 to 50 years). All the patients suffered from bilateral deafness, were right-handed, and had no additional neurological deficits. They underwent PET imaging three times: immediately after the first fitting of the speech processor (activation of the cochlear implant), and one and two years later. A tendency towards increasing levels of activation in areas of the primary and secondary auditory cortex on the left side of the brain was observed. There was no clear effect of the side of implantation (left or right) on the degree of cortical activation in the temporal lobe. However, the PET results showed a correlation between degree of cortical activation and speech therapy results.
Łukaszewicz-Moszyńska, Zuzanna; Lachowska, Magdalena; Niemczyk, Kazimierz
2014-01-01
Summary The purpose of this study was to evaluate possible relationships between duration of cochlear implant use and results of positron emission tomography (PET) measurements in the temporal lobes performed while subjects listened to speech stimuli. Other aspects investigated were whether implantation side impacts significantly on cortical representations of functions related to understanding speech (ipsi- or contralateral to the implanted side) and whether any correlation exists between cortical activation and speech therapy results. Objective cortical responses to acoustic stimulation were measured, using PET, in nine cochlear implant patients (age range: 15 to 50 years). All the patients suffered from bilateral deafness, were right-handed, and had no additional neurological deficits. They underwent PET imaging three times: immediately after the first fitting of the speech processor (activation of the cochlear implant), and one and two years later. A tendency towards increasing levels of activation in areas of the primary and secondary auditory cortex on the left side of the brain was observed. There was no clear effect of the side of implantation (left or right) on the degree of cortical activation in the temporal lobe. However, the PET results showed a correlation between degree of cortical activation and speech therapy results. PMID:25306122
Loiselle, Louise H; Dorman, Michael F; Yost, William A; Cook, Sarah J; Gifford, Rene H
2016-08-01
To assess the role of interaural time differences and interaural level differences in (a) sound-source localization, and (b) speech understanding in a cocktail party listening environment for listeners with bilateral cochlear implants (CIs) and for listeners with hearing-preservation CIs. Eleven bilateral listeners with MED-EL (Durham, NC) CIs and 8 listeners with hearing-preservation CIs with symmetrical low frequency, acoustic hearing using the MED-EL or Cochlear device were evaluated using 2 tests designed to task binaural hearing, localization, and a simulated cocktail party. Access to interaural cues for localization was constrained by the use of low-pass, high-pass, and wideband noise stimuli. Sound-source localization accuracy for listeners with bilateral CIs in response to the high-pass noise stimulus and sound-source localization accuracy for the listeners with hearing-preservation CIs in response to the low-pass noise stimulus did not differ significantly. Speech understanding in a cocktail party listening environment improved for all listeners when interaural cues, either interaural time difference or interaural level difference, were available. The findings of the current study indicate that similar degrees of benefit to sound-source localization and speech understanding in complex listening environments are possible with 2 very different rehabilitation strategies: the provision of bilateral CIs and the preservation of hearing.
Binaural hearing with electrical stimulation.
Kan, Alan; Litovsky, Ruth Y
2015-04-01
Bilateral cochlear implantation is becoming a standard of care in many clinics. While much benefit has been shown through bilateral implantation, patients who have bilateral cochlear implants (CIs) still do not perform as well as normal hearing listeners in sound localization and understanding speech in noisy environments. This difference in performance can arise from a number of different factors, including the areas of hardware and engineering, surgical precision and pathology of the auditory system in deaf persons. While surgical precision and individual pathology are factors that are beyond careful control, improvements can be made in the areas of clinical practice and the engineering of binaural speech processors. These improvements should be grounded in a good understanding of the sensitivities of bilateral CI patients to the acoustic binaural cues that are important to normal hearing listeners for sound localization and speech in noise understanding. To this end, we review the current state-of-the-art in the understanding of the sensitivities of bilateral CI patients to binaural cues in electric hearing, and highlight the important issues and challenges as they relate to clinical practice and the development of new binaural processing strategies. This article is part of a Special Issue entitled
Dietz, Mathias; Hohmann, Volker; Jürgens, Tim
2015-01-01
For normal-hearing listeners, speech intelligibility improves if speech and noise are spatially separated. While this spatial release from masking has already been quantified in normal-hearing listeners in many studies, it is less clear how spatial release from masking changes in cochlear implant listeners with and without access to low-frequency acoustic hearing. Spatial release from masking depends on differences in access to speech cues due to hearing status and hearing device. To investigate the influence of these factors on speech intelligibility, the present study measured speech reception thresholds in spatially separated speech and noise for 10 different listener types. A vocoder was used to simulate cochlear implant processing and low-frequency filtering was used to simulate residual low-frequency hearing. These forms of processing were combined to simulate cochlear implant listening, listening based on low-frequency residual hearing, and combinations thereof. Simulated cochlear implant users with additional low-frequency acoustic hearing showed better speech intelligibility in noise than simulated cochlear implant users without acoustic hearing and had access to more spatial speech cues (e.g., higher binaural squelch). Cochlear implant listener types showed higher spatial release from masking with bilateral access to low-frequency acoustic hearing than without. A binaural speech intelligibility model with normal binaural processing showed overall good agreement with measured speech reception thresholds, spatial release from masking, and spatial speech cues. This indicates that differences in speech cues available to listener types are sufficient to explain the changes of spatial release from masking across these simulated listener types. PMID:26721918
Audiological outcomes of cochlear implantation in Waardenburg Syndrome.
Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira
2013-07-01
The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.
Personal reflections on the multichannel cochlear implant and a view of the future.
Clark, Graeme M
2008-01-01
The multichannel cochlear implant is the first neural prosthesis to effectively and safely bring electronic technology into a direct physiological relation with the central nervous system and human consciousness. It is also the first cochlear implant to give speech understanding to tens of thousands of persons with profound deafness and spoken language to children born deaf in more than 80 countries. In so doing, it is the first major advance in research and technology to help deaf children communicate since Sign Language of the Deaf was developed at the Paris deaf school (L'Institut National de Jeunes Sourds de Paris) >200 years ago. Furthermore, biomedical research has been fundamental for ensuring that the multielectrode implant is safe as well as effective. More recent research has also shown that bilateral implants confer the benefits of binaural hearing. Future research using nanotechnology should see high-fidelity sound received, which would help deaf persons communicate in noise and enjoy music. Research should also lead to implants in ears with useful hearing.
Galvin, Karyn Louise; Mok, Mansze; Dowell, Richard C
2007-08-01
To evaluate the additional perceptual benefit provided to children through the use of two cochlear implants in comparison to one after 6 to 13 mo experience with sequential bilateral implants. A second cochlear implant was received by 11 children. The principal selection criteria were being age 4 to 15 yr with a bilateral profound hearing loss and being a consistent user of a first implant with a commitment to use of a second implant. Horizontal localization was assessed by using pink noise bursts presented from a 180 degrees , eight-loudspeaker array. Speech perception was assessed by using a four-alternative forced-choice spondee test, with speech presented from in front and adaptive background noise presented from 90 degrees to the left or right. Both tests were completed in the first implant alone and bilateral conditions. A questionnaire measured the pre- to postoperative change in the parent's ratings of the child's performance in specific listening situations. Items were related to speech perception, spatial hearing, or other qualities of hearing. Regular parental reports of device use, attitude and performance were collected. Most subjects were assessed at 6 mo after surgery, with two assessed at 13 mo. The 11 subjects demonstrated a great range of outcomes. For one subject, only anecdotal data were collected. Speech perception testing indicated that when noise was presented ipsilateral to the first implant, 8 of 10 subjects showed a benefit in the bilateral condition. None of the nine subjects tested showed a benefit when noise was contralateral to the first implant. Generally, there was no benefit to localization in the bilateral condition. For eight subjects, postoperative performance ratings were generally higher than preoperative ratings, particularly in the spatial hearing section. Anecdotal reports indicated that most subjects had a negative attitude toward, and gained limited experience with, the second implant alone. The subjects developed a range of speech perception skills, from detection to conversation level. Regarding the use of bilateral implants, attitudes were more positive and device use was consistent for eight subjects, and six parents reported some evidence of improved performance in daily life. Children over age 4 yr may gain significant additional benefit from a second implant, including improved speech perception in some noise contexts and functional advantages in daily life. There is, however, no evidence from this study to suggest that binaural listening skills, including localization, will develop during the first 6 mo. Furthermore, some children who may be committed users of a first implant may not adapt to or benefit from a second implant during the first 6 mo of device use. Although the factors influencing benefit cannot be clearly identified, limited preoperative auditory experience with the second ear, a delay of years between implants, relatively advanced age, and lack of second-implant-alone experience do not preclude benefit. Continued evaluation of these and additional subjects will clarify the factors that do contribute to benefit. Such information will be vital in helping families of implanted children to make an informed decision regarding a second implant.
Schvartz-Leyzac, Kara C; Pfingst, Bryan E
2016-11-01
Electrically evoked compound action potential (ECAP) measures of peak amplitude, and amplitude-growth function (AGF) slope have been shown to reflect characteristics of cochlear health (primarily spiral ganglion density) in anesthetized cochlear-implanted guinea pigs. Likewise, the effect of increasing the interphase gap (IPG) in each of these measures also reflects SGN density in the implanted guinea pig. Based on these findings, we hypothesize that suprathreshold ECAP measures, and also how they change as the IPG is increased, have the potential to be clinically applicable in human subjects. However, further work is first needed in order to determine the characteristics of these measures in humans who use cochlear implants. The current study examined across-site patterns of suprathreshold ECAP measures in 10 bilaterally-implanted, adult cochlear implant users. Results showed that both peak amplitude and slope of the AGF varied significantly from electrode to electrode in ear-specific patterns across the subjects' electrode arrays. As expected, increasing the IPG on average increased the peak amplitude and slope. Across ears, there was a significant, negative correlation between the slope of the ECAP AGF and the duration of hearing loss. Across-site patterns of ECAP peak amplitude and AGF slopes were also compared with common ground impedance values and significant correlations were observed in some cases, depending on the subject and condition. The results of this study, coupled with previous studies in animals, suggest that it is feasible to measure the change in suprathreshold ECAP measures as the IPG increases on most electrodes. Further work is needed to investigate the relationship between these measures and cochlear implant outcomes, and determine how these measures might be used when programming a cochlear-implant processor. Published by Elsevier B.V.
Bilateral Cochlear Implants: Maximizing Expected Outcomes.
Wallis, Kate E; Blum, Nathan J; Waryasz, Stephanie A; Augustyn, Marilyn
Sonia is a 4 years 1 month-year-old girl with Waardenburg syndrome and bilateral sensorineural hearing loss who had bilateral cochlear implants at 2 years 7 months years of age. She is referred to Developmental-Behavioral Pediatrics by her speech/language pathologist because of concerns that her language skills are not progressing as expected after the cochlear implant. At the time of the implant, she communicated using approximately 20 signs and 1 spoken word (mama). At the time of the evaluation (18 months after the implant) she had approximately 70 spoken words (English and Spanish) and innumerable signs that she used to communicate. She could follow 1-step directions in English but had more difficulty after 2-step directions.Sonia was born in Puerto Rico at 40 weeks gestation after an uncomplicated pregnancy. She failed her newborn hearing test and was given hearing aids that did not seem to help.At age 2 years, Sonia, her mother, and younger sister moved to the United States where she was diagnosed with bilateral severe-to-profound hearing loss. Genetic testing led to a diagnosis of Waardenburg syndrome (group of genetic conditions that can cause hearing loss and changes in coloring [pigmentation] of the hair, skin, and eyes). She received bilateral cochlear implants 6 months later.Sonia's mother is primarily Spanish-speaking and mostly communicates with her in Spanish or with gestures but has recently begun to learn American Sign Language (ASL). In a preschool program at a specialized school for the deaf, Sonia is learning both English and ASL. Sonia seems to prefer to use ASL to communicate.Sonia receives speech and language therapy (SLT) 3 times per week (90 minutes total) individually in school and once per week within a group. She is also receiving outpatient SLT once per week. Therapy sessions are completed in English, with the aid of an ASL interpreter. Sonia's language scores remain low, with her receptive skills in the first percentile, and her expressive skills in the fifth percentile.During her evaluation in Developmental and Behavioral Pediatrics, an ASL interpreter was present, and the examiner is a fluent Spanish speaker. Testing was completed through a combination of English, Spanish, and ASL. Sonia seemed to prefer ASL to communicate, although she used some English words with errors of pronunciation. On the Beery Visual-Motor Integration Test, she obtained a standard score of 95. Parent and teacher rating scales were not significant for symptoms of attention-deficit/hyperactivity disorder.What factors are contributing to her slow language acquisition and how would you modify her treatment plan?
The Impact of Cochlear Implant in the Oral Language of Children with Congenital Deafness.
Ramos, Daniela; Jorge, João Xavier; Teixeira, António; Ribeiro, Carlos; Paiva, António
2015-01-01
Children with severe to profound sensorineural deafness can acquire vocabulary and syntactic structures to communicate by oral language, after cochlear implant. Identify the linguistic skills of children with cochlear implant. Eighteen children of both gender, between 9 and 10 years, with congenital bilateral deafness, using cochlear implant, were studied. The evaluation instrument used was Observation Chart of Language-School Level. The results were compared with standard of normal-hearing children with the same hearing age. The scores registered in the linguistics structures studied, comparing implanted children and standard, was: phonology, 29.44 ± 8.4 vs. 29.68 ± 5.90, p = 0.91; semantics, 18.55 ± 8.89 vs. 19.20 ± 4.85, p = 0.76; morpho-syntax 21.89 ± 12.85 vs. 26.35 ± 10.36, p = 0.159. Regarding the tests of semantics, there was no significant difference. Concerning the tests of morpho-syntactic structure, the difference was significant in the derivation of words, 2.83 ± 2.81 vs. 4.65 ± 1.64, p = 0.014. In the phonology, a significant difference was found comparing implanted children and standard, in the discrimination of pseudo words, 6.6 ± 2.8 vs. 8.37 ± 2.32, p = 0.023. However, in syllabic segmentation, implanted children had a mean score 8.56 ± 1.6 significantly higher than standard, 5.9 ± 1.58, p < 0.001. The similarity of the scores obtained by children with cochlear implants with the standard, in the language components studied confirms that cochlear implant promotes the development of oral verbal language in children with congenital deafness. Implanted children had acquired language skills similar to normal-hearing children with the same hearing age.
Cozma, Romică Sebastian; Dima-Cozma, Lucia Corina; Rădulescu, Luminiţa Mihaela; Hera, Maria Cristina; Mârţu, Cristian; Olariu, Raluca; Cobzeanu, Bogdan Mihail; Bitere, Oana Roxana; Cobzeanu, Mihail Dan
2018-01-01
Patients with hearing loss who underwent cochlear implantation can present symptomatic or asymptomatic vestibular damages earlier or later after the surgery. The vestibular permanent lesions could be acute, produced by surgical trauma or could be progressive due to local morphological changes made by the presence of the portelectrode in the inner ear (fibrosis related, ossification, basilar membrane distortion, endolymphatic hydrops). Besides histopathological findings in inner ear of cochlear implanted patients, the vestibular permanent damages could be found by assessment of clinical vestibular status. This study reports the sensorial vestibular functional findings for adults in cochlear implanted ears related to the electrode insertion type (cochleostomy or round window approach) and comparing to non-implanted deaf ears. A total of 20 adult patients with 32 cochlear implanted ears (12 patients with binaural cochlear implant and eight with monoaural) were selected for postoperatory vestibular examination by cervical and ocular vestibular myogenic potentials and vestibular caloric tests. The same tests were made for a control group of 22 non-implanted deaf ears. Functional testing results were reported related to the electrode insertion approach. For the cochleostomy group, we found different deficits: in 40% for saccular function, 44% for utricular function, and 12% horizontal canal dysfunction. In round window group, the deficit was present in 14.29% for saccular function, 28.57% for utricular function, and 28.58% for horizontal canal. In 46.88% of implanted ears, the vestibular function was completely preserved on all tested sensors. In conclusion, the vestibular functional status after inner ear surgery presents sensorial damages in 53.12% ears compare with the vestibular dysfunction existing in 50% of deaf non-operated ears. Round window insertion allows for better conservation of the vestibular function.
Henkin, Yael; Kishon-Rabin, Liat; Tatin-Schneider, Simona; Urbach, Doron; Hildesheimer, Minka; Kileny, Paul R
2004-12-01
The current preliminary report describes the utilization of low-resolution electromagnetic tomography (LORETA) in a small group of highly performing children using the Nucleus 22 cochlear implant (CI) and in normal-hearing (NH) adults. LORETA current density estimations were performed on an averaged target P3 component that was elicited by non-speech and speech oddball discrimination tasks. The results indicated that, when stimulated with tones, patients with right implants and NH adults (regardless of stimulated ear) showed enhanced activation in the right temporal lobe, whereas patients with left implants showed enhanced activation in the left temporal lobe. When stimulated with speech, patients with right implants showed bilateral activation of the temporal and frontal lobes, whereas patients with left implants showed only left temporal lobe activation. NH adults (regardless of stimulated ear) showed enhanced bilateral activation of the temporal and parietal lobes. The differences in activation patterns between patients with CI and NH subjects may be attributed to the long-term exposure to degraded input conditions which may have resulted in reorganization in terms of functional specialization. The difference between patients with right versus left implants, however, is intriguing and requires further investigation.
Gifford, René H.; Grantham, D. Wesley; Sheffield, Sterling W.; Davis, Timothy J.; Dwyer, Robert; Dorman, Michael F.
2014-01-01
The purpose of this study was to investigate horizontal plane localization and interaural time difference (ITD) thresholds for 14 adult cochlear implant recipients with hearing preservation in the implanted ear. Localization to broadband noise was assessed in an anechoic chamber with a 33-loudspeaker array extending from −90 to +90°. Three listening conditions were tested including bilateral hearing aids, bimodal (implant + contralateral hearing aid) and best aided (implant + bilateral hearing aids). ITD thresholds were assessed, under headphones, for low-frequency stimuli including a 250-Hz tone and bandpass noise (100–900 Hz). Localization, in overall rms error, was significantly poorer in the bimodal condition (mean: 60.2°) as compared to both bilateral hearing aids (mean: 46.1°) and the best-aided condition (mean: 43.4°). ITD thresholds were assessed for the same 14 adult implant recipients as well as 5 normal-hearing adults. ITD thresholds were highly variable across the implant recipients ranging from the range of normal to ITDs not present in real-world listening environments (range: 43 to over 1600 μs). ITD thresholds were significantly correlated with localization, the degree of interaural asymmetry in low-frequency hearing, and the degree of hearing preservation related benefit in the speech reception threshold (SRT). These data suggest that implant recipients with hearing preservation in the implanted ear have access to binaural cues and that the sensitivity to ITDs is significantly correlated with localization and degree of preserved hearing in the implanted ear. PMID:24607490
Gifford, René H; Grantham, D Wesley; Sheffield, Sterling W; Davis, Timothy J; Dwyer, Robert; Dorman, Michael F
2014-06-01
The purpose of this study was to investigate horizontal plane localization and interaural time difference (ITD) thresholds for 14 adult cochlear implant recipients with hearing preservation in the implanted ear. Localization to broadband noise was assessed in an anechoic chamber with a 33-loudspeaker array extending from -90 to +90°. Three listening conditions were tested including bilateral hearing aids, bimodal (implant + contralateral hearing aid) and best aided (implant + bilateral hearing aids). ITD thresholds were assessed, under headphones, for low-frequency stimuli including a 250-Hz tone and bandpass noise (100-900 Hz). Localization, in overall rms error, was significantly poorer in the bimodal condition (mean: 60.2°) as compared to both bilateral hearing aids (mean: 46.1°) and the best-aided condition (mean: 43.4°). ITD thresholds were assessed for the same 14 adult implant recipients as well as 5 normal-hearing adults. ITD thresholds were highly variable across the implant recipients ranging from the range of normal to ITDs not present in real-world listening environments (range: 43 to over 1600 μs). ITD thresholds were significantly correlated with localization, the degree of interaural asymmetry in low-frequency hearing, and the degree of hearing preservation related benefit in the speech reception threshold (SRT). These data suggest that implant recipients with hearing preservation in the implanted ear have access to binaural cues and that the sensitivity to ITDs is significantly correlated with localization and degree of preserved hearing in the implanted ear. Copyright © 2014. Published by Elsevier B.V.
Cochlear Implantation in Siblings With Refsum's Disease.
Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana
2017-08-01
Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.
Della Santina, Charles C.; Migliaccio, Americo A.; Hayden, Russell; Melvin, Thuy-Anh; Fridman, Gene Y.; Chiang, Bryce; Davidovics, Natan S.; Dai, Chenkai; Carey, John P.; Minor, Lloyd B.; Anderson, Iee-Ching; Park, HongJu; Lyford-Pike, Sofia; Tang, Shan
2012-01-01
Bilateral loss of vestibular sensation can disable individuals whose vestibular hair cells are injured by ototoxic medications, infection, Ménière’s disease or other insults to the labyrinth including surgical trauma during cochlear implantation. Without input to vestibulo-ocular and vestibulo-spinal reflexes that normally stabilize the eyes and body, affected patients suffer blurred vision during head movement, postural instability, and chronic disequilibrium. While individuals with some residual sensation often compensate for their loss through rehabilitation exercises, those who fail to do so are left with no adequate treatment options. An implantable neuroelectronic vestibular prosthesis that emulates the normal labyrinth by sensing head movement and modulating activity on appropriate branches of the vestibular nerve could significantly improve quality of life for these otherwise chronically dizzy patients. This brief review describes the impact and current management of bilateral loss of vestibular sensation, animal studies supporting the feasibility of prosthetic vestibular stimulation, and a vestibular prosthesis designed to restore sensation of head rotation in all directions. Similar to a cochlear implant in concept and size, the Johns Hopkins Multichannel Vestibular Prosthesis (MVP) includes miniature gyroscopes to sense head rotation, a microcontroller to process inputs and control stimulus timing, and current sources switched between pairs of electrodes implanted within the vestibular labyrinth. In rodents and rhesus monkeys rendered bilaterally vestibular-deficient via treatment with gentamicin and/or plugging of semicircular canals, the MVP partially restores the vestibulo-ocular reflex for head rotations about any axis of rotation in 3-dimensional space. Our efforts now focus on addressing issues prerequisite to human implantation, including refinement of electrode designs and surgical technique to enhance stimulus selectivity and preserve cochlear function, optimization of stimulus protocols, and reduction of device size and power consumption. PMID:21756683
Aronoff, Justin M.; Padilla, Monica; Fu, Qian-Jie; Landsberger, David M.
2015-01-01
Contralateral masking is the phenomenon where a masker presented to one ear affects the ability to detect a signal in the opposite ear. For normal hearing listeners, contralateral masking results in masking patterns that are both sharper and dramatically smaller in magnitude than ipsilateral masking. The goal of this study was to investigate whether medial olivocochlear (MOC) efferents are needed for the sharpness and relatively small magnitude of the contralateral masking function. To do this, bilateral cochlear implant patients were tested because, by directly stimulating the auditory nerve, cochlear implants circumvent the effects of the MOC efferents. The results indicated that, as with normal hearing listeners, the contralateral masking function was sharper than the ipsilateral masking function. However, although there was a reduction in the magnitude of the contralateral masking function compared to the ipsilateral masking function, it was relatively modest. This is in sharp contrast to the results of normal hearing listeners where the magnitude of the contralateral masking function is greatly reduced. These results suggest that MOC function may not play a large role in the sharpness of the contralateral masking function but may play a considerable role in the magnitude of the contralateral masking function. PMID:25798581
Baumgärtel, Regina M; Hu, Hongmei; Krawczyk-Becker, Martin; Marquardt, Daniel; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Bomke, Katrin; Plotz, Karsten; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias
2015-12-30
Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT50) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT50 improvements measured in bilaterally implanted CI users. © The Author(s) 2015.
Basta, Dietmar; Götze, Romy; Gröschel, Moritz; Jansen, Sebastian; Janke, Oliver; Tzschentke, Barbara; Boyle, Patrick; Ernst, Arne
2015-12-01
In recent years, cochlear implants have been applied successfully for the treatment of unilateral hearing loss with quite surprising benefit. One reason for this successful treatment, including the relief from tinnitus, could be the normalization of spontaneous activity in the central auditory pathway because of the electrical stimulation. The present study, therefore, investigated at a cellular level, the effect of a unilateral chronic intracochlear stimulation on key structures of the central auditory pathway. Normal-hearing guinea pigs were mechanically single-sided deafened through a standard HiFocus1j electrode array (on a HiRes 90k cochlear implant) being inserted into the first turn of the cochlea. Four to five electrode contacts could be used for the stimulation. Six weeks after surgery, the speech processor (Auria) was fitted, based on tNRI values and mounted on the animal's back. The two experimental groups were stimulated 16 hours per day for 90 days, using a HiRes strategy based on different stimulation rates (low rate (275 pps/ch), high rate (5000 pps/ch)). The results were compared with those of unilateral deafened controls (implanted but not stimulated), as well as between the treatment groups. All animals experienced a standardized free field auditory environment. The low-rate group showed a significantly lower average spontaneous activity bilaterally in the dorsal cochlear nucleus and the medial geniculate body than the controls. However, there was no difference in the inferior colliculus and the primary auditory cortex. Spontaneous activity of the high-rate group was also reduced bilaterally in the dorsal cochlear nucleus and in the primary auditory cortex. No differences could be observed between the high-rate group and the controls in the contra-lateral inferior colliculus and medial geniculate body. The high-rate group showed bilaterally a higher activity in the CN and the MGB compared with the low-rate group, whereas in the IC and in the AC a trend for an opposite effect could be determined. Unilateral intracochlear electrical stimulation seems to facilitate the homeostasis of the network activity, since it decreases the spontaneous activity that is usually elevated upon deafferentiation. The electrical stimulation per se seems to be responsible for the bilateral changes described above, rather than the particular nature of the electrical stimulation (e.g., rate). The normalization effects of electrical stimulation found in the present study are of particular importance in cochlear implant recipients with single-sided deafness.
Audiological outcomes of cochlear implantation in Waardenburg Syndrome
Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira
2013-01-01
Summary Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception. PMID:25992025
Verhaert, N; Willems, M; Van Kerschaver, E; Desloovere, C
2008-05-01
Early intervention in hearing-impaired children may improve language outcomes and subsequent school and occupational performance. The objective of this study was to retrospectively analyze over 6 years the educational outcome and language development of a first cohort of children, detected by the Flemish universal newborn hearing screening (UNHS) program based on automated auditory brainstem response (AABR), with the oldest children being in primary school. We studied 229 hearing-impaired children from 1998 till 2003. The following variables were considered: the age during the school year 2005-2006, the degree of hearing loss, additional impairments including presence of intellectual disability, school placement and early intervention. Analysis showed that 85.4% of the children with moderate, severe or profound hearing loss and no additional disability, older than 5.5 years, reach mainstream education. Further detailed description was provided for the outcomes of children with uni- and bilateral cochlear implants. Overall results stress that 46% of all children with a cochlear implant obtain mainstream education. Of all cochlear implant (CI) children above 5.5 years, without additional handicaps, 78.9% of children attend primary mainstream school. Data on language development show that up to 45% of the children with unilateral cochlear implant and no additional disabilities had normal to slight delay on language development. These data are fulfilling the goals stated by the JCIH and the American Academy of Pediatrics (AAP) in 2000. The role and impact of additional handicaps is discussed. The importance of early hearing loss identification and hearing therapy for appropriate language development is highlighted. Finally our preliminary results on children with bilateral cochlear implants without additional handicaps present an improved language development in comparison to unilateral CI-children. A vast majority of the children detected by the UNHS program, with moderate, severe or profound hearing loss and no additional disability, older than 5.5 years, reach mainstream education. Additional disabilities have a major influence.
Cochlear Implantation in Adults with Asymmetric Hearing Loss
Firszt, Jill B.; Holden, Laura K.; Reeder, Ruth M.; Cowdrey, Lisa; King, Sarah
2012-01-01
Objective Bilateral severe-to-profound sensorineural hearing loss is a standard criterion for cochlear implantation. Increasingly, patients are implanted in one ear and continue to use a hearing aid in the non-implanted ear to improve abilities such as sound localization and speech understanding in noise. Patients with severe-to-profound hearing loss in one ear and a more moderate hearing loss in the other ear (i.e., asymmetric hearing) are not typically considered candidates for cochlear implantation. Amplification in the poorer ear is often unsuccessful due to limited benefit, restricting the patient to unilateral listening from the better ear alone. The purpose of this study was to determine if patients with asymmetric hearing loss could benefit from cochlear implantation in the poorer ear with continued use of a hearing aid in the better ear. Design Ten adults with asymmetric hearing between ears participated. In the poorer ear, all participants met cochlear implant candidacy guidelines; seven had postlingual onset and three had pre/perilingual onset of severe-to-profound hearing loss. All had open-set speech recognition in the better hearing ear. Assessment measures included word and sentence recognition in quiet, sentence recognition in fixed noise (four-talker babble) and in diffuse restaurant noise using an adaptive procedure, localization of word stimuli and a hearing handicap scale. Participants were evaluated pre-implant with hearing aids and post-implant with the implant alone, the hearing aid alone in the better ear and bimodally (the implant and hearing aid in combination). Postlingual participants were evaluated at six months post-implant and pre/perilingual participants were evaluated at six and 12 months post-implant. Data analysis compared results 1) of the poorer hearing ear pre-implant (with hearing aid) and post-implant (with cochlear implant), 2) with the device(s) used for everyday listening pre- and post-implant and, 3) between the hearing aid-alone and bimodal listening conditions post-implant. Results The postlingual participants showed significant improvements in speech recognition after six months cochlear implant use in the poorer ear. Five postlingual participants had a bimodal advantage over the hearing aid-alone condition on at least one test measure. On average, the postlingual participants had significantly improved localization with bimodal input compared to the hearing aid-alone. Only one pre/perilingual participant had open-set speech recognition with the cochlear implant. This participant had better hearing than the other two pre/perilingual participants in both the poorer and better ear. Localization abilities were not significantly different between the bimodal and hearing aid-alone conditions for the pre/perilingual participants. Mean hearing handicap ratings improved post-implant for all participants indicating perceived benefit in everyday life with the addition of the cochlear implant. Conclusions Patients with asymmetric hearing loss who are not typical cochlear implant candidates can benefit from using a cochlear implant in the poorer ear with continued use of a hearing aid in the better ear. For this group of ten, the seven postlingually deafened participants showed greater benefits with the cochlear implant than the pre/perilingual participants; however, further study is needed to determine maximum benefit for those with early onset of hearing loss. PMID:22441359
ERIC Educational Resources Information Center
Gifford, Rene H.; Dorman, Michael F.; McKarns, Sharon A.; Spahr, Anthony J.
2007-01-01
Purpose: The authors assessed whether (a) a full-insertion cochlear implant would provide a higher level of speech understanding than bilateral low-frequency acoustic hearing, (b) contralateral acoustic hearing would add to the speech understanding provided by the implant, and (c) the level of performance achieved with electric stimulation plus…
Speech recognition by bilateral cochlear implant users in a cocktail-party setting
Loizou, Philipos C.; Hu, Yi; Litovsky, Ruth; Yu, Gongqiang; Peters, Robert; Lake, Jennifer; Roland, Peter
2009-01-01
Unlike prior studies with bilateral cochlear implant users which considered only one interferer, the present study considered realistic listening situations wherein multiple interferers were present and in some cases originating from both hemifields. Speech reception thresholds were measured in bilateral users unilaterally and bilaterally in four different spatial configurations, with one and three interferers consisting of modulated noise or competing talkers. The data were analyzed in terms of binaural benefits including monaural advantage (better-ear listening) and binaural interaction. The total advantage (overall spatial release) received was 2–5 dB and was maintained with multiple interferers present. This advantage was dominated by the monaural advantage, which ranged from 1 to 6 dB and was largest when the interferers were mostly energetic. No binaural-interaction benefit was found in the present study with either type of interferer (speech or noise). While the total and monaural advantage obtained for noise interferers was comparable to that attained by normal-hearing listeners, it was considerably lower for speech interferers. This suggests that bilateral users are less capable of taking advantage of binaural cues, in particular, under conditions of informational masking. Furthermore, the use of noise interferers does not adequately reflect the difficulties experienced by bilateral users in real-life situations. PMID:19173424
Todd, Ann E.; Goupell, Matthew J.; Litovsky, Ruth Y.
2016-01-01
Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs. PMID:27475132
Shah, Parth V; Kozin, Elliott D; Kaplan, Alyson B; Lee, Daniel J
2016-01-01
The auditory brainstem implant (ABI) is a neuroprosthetic device that provides sound sensations to individuals with profound hearing loss who are not candidates for a cochlear implant (CI) because of anatomic constraints. Herein we describe the ABI for family physicians. PubMed was searched to identify articles relevant to the ABI, as well as articles that contain outcomes data for pediatric patients (age <18 years) who have undergone ABI surgery. The ABI was originally developed for patients with neurofibromatosis type 2 (NF2) who become deaf from bilateral vestibular schwannomas. Over the past decade, indications for an ABI have expanded to adult patients without tumors (without NF2) who cannot receive a CI and children with no cochlea or cochlear nerve. Outcomes among NF2 ABI users are modest compared to cochlear implant patients, but recent studies from Europe suggest that some non-tumor adult and pediatric ABI users achieve speech perception. The ABI is a reasonable surgical option for children with profound hearing loss due to severe cochlear or cochlear nerve deformities. Continued prospective data collection from several clinical trials in the U.S. will provide greater understanding on long term outcomes that focus on speech intelligibility. © Copyright 2016 by the American Board of Family Medicine.
Recognition and production of emotions in children with cochlear implants.
Mildner, Vesna; Koska, Tena
2014-01-01
The aim of this study was to examine auditory recognition and vocal production of emotions in three prelingually bilaterally profoundly deaf children aged 6-7 who received cochlear implants before age 2, and compare them with age-matched normally hearing children. No consistent advantage was found for the normally hearing participants. In both groups, sadness was recognized best and disgust was the most difficult. Confusion matrices among other emotions (anger, happiness, and fear) showed that children with and without hearing impairment may rely on different cues. Both groups of children showed that perception is superior to production. Normally hearing children were more successful in the production of sadness, happiness, and fear, but not anger or disgust. The data set is too small to draw any definite conclusions, but it seems that a combination of early implantation and regular auditory-oral-based therapy enables children with cochlear implants to process and produce emotional content comparable with children with normal hearing.
Cochlear implantation for severe sensorineural hearing loss caused by lightning.
Myung, Nam-Suk; Lee, Il-Woo; Goh, Eui-Kyung; Kong, Soo-Keun
2012-01-01
Lightning strike can produce an array of clinical symptoms and injuries. It may damage multiple organs and cause auditory injuries ranging from transient hearing loss and vertigo to complete disruption of the auditory system. Tympanic-membrane rupture is relatively common in patients with lightning injury. The exact pathogenetic mechanisms of auditory lesions in lightning survivors have not been fully elucidated. We report the case of a 45-year-old woman with bilateral profound sensorineural hearing loss caused by a lightning strike, who was successfully rehabilitated after a cochlear implantation. Copyright © 2012 Elsevier Inc. All rights reserved.
A speech processing study using an acoustic model of a multiple-channel cochlear implant
NASA Astrophysics Data System (ADS)
Xu, Ying
1998-10-01
A cochlear implant is an electronic device designed to provide sound information for adults and children who have bilateral profound hearing loss. The task of representing speech signals as electrical stimuli is central to the design and performance of cochlear implants. Studies have shown that the current speech- processing strategies provide significant benefits to cochlear implant users. However, the evaluation and development of speech-processing strategies have been complicated by hardware limitations and large variability in user performance. To alleviate these problems, an acoustic model of a cochlear implant with the SPEAK strategy is implemented in this study, in which a set of acoustic stimuli whose psychophysical characteristics are as close as possible to those produced by a cochlear implant are presented on normal-hearing subjects. To test the effectiveness and feasibility of this acoustic model, a psychophysical experiment was conducted to match the performance of a normal-hearing listener using model- processed signals to that of a cochlear implant user. Good agreement was found between an implanted patient and an age-matched normal-hearing subject in a dynamic signal discrimination experiment, indicating that this acoustic model is a reasonably good approximation of a cochlear implant with the SPEAK strategy. The acoustic model was then used to examine the potential of the SPEAK strategy in terms of its temporal and frequency encoding of speech. It was hypothesized that better temporal and frequency encoding of speech can be accomplished by higher stimulation rates and a larger number of activated channels. Vowel and consonant recognition tests were conducted on normal-hearing subjects using speech tokens processed by the acoustic model, with different combinations of stimulation rate and number of activated channels. The results showed that vowel recognition was best at 600 pps and 8 activated channels, but further increases in stimulation rate and channel numbers were not beneficial. Manipulations of stimulation rate and number of activated channels did not appreciably affect consonant recognition. These results suggest that overall speech performance may improve by appropriately increasing stimulation rate and number of activated channels. Future revision of this acoustic model is necessary to provide more accurate amplitude representation of speech.
Phonological Awareness at 5 years of age in Children who use Hearing Aids or Cochlear Implants
Ching, Teresa Y.C.; Cupples, Linda
2015-01-01
Children with hearing loss typically underachieve in reading, possibly as a result of their underdeveloped phonological skills. This study addressed the questions of whether the development of phonological awareness (PA) is influenced by 1) the degree of hearing loss; and 2) whether performance of children with severe-profound hearing loss differed according to the hearing devices used. Drawing on data collected as part of the Longitudinal Outcomes of Children with Hearing Impairment (LOCHI, www.outcomes.nal.gov.au) study, the authors found that sound-matching scores of children with hearing loss ranging from mild to profound degrees were, on average, within the normal range. The degree of hearing loss did not have a significant impact on scores, but there was a non-significant tendency for the proportion of children who achieved zero scores to increase with increase in hearing loss. For children with severe hearing loss, there was no significant group difference in scores among children who used bilateral hearing aids, bimodal fitting (a cochlear implant and a hearing aid in contralateral ears), and bilateral cochlear implants. Although there is a need for further prospective research, professionals have an important role in targeting PA skills for rehabilitation of young children with hearing loss. PMID:26929789
Binaural enhancement for bilateral cochlear implant users.
Brown, Christopher A
2014-01-01
Bilateral cochlear implant (BCI) users receive limited binaural cues and, thus, show little improvement to speech intelligibility from spatial cues. The feasibility of a method for enhancing the binaural cues available to BCI users is investigated. This involved extending interaural differences of levels, which typically are restricted to high frequencies, into the low-frequency region. Speech intelligibility was measured in BCI users listening over headphones and with direct stimulation, with a target talker presented to one side of the head in the presence of a masker talker on the other side. Spatial separation was achieved by applying either naturally occurring binaural cues or enhanced cues. In this listening configuration, BCI patients showed greater speech intelligibility with the enhanced binaural cues than with naturally occurring binaural cues. In some situations, it is possible for BCI users to achieve greater speech intelligibility when binaural cues are enhanced by applying interaural differences of levels in the low-frequency region.
Litovsky, Ruth Y.; Gordon, Karen
2017-01-01
Spatial hearing skills are essential for children as they grow, learn and play. They provide critical cues for determining the locations of sources in the environment, and enable segregation of important sources, such as speech, from background maskers or interferers. Spatial hearing depends on availability of monaural cues and binaural cues. The latter result from integration of inputs arriving at the two ears from sounds that vary in location. The binaural system has exquisite mechanisms for capturing differences between the ears in both time of arrival and intensity. The major cues that are thus referred to as being vital for binaural hearing are: interaural differences in time (ITDs) and interaural differences in levels (ILDs). In children with normal hearing (NH), spatial hearing abilities are fairly well developed by age 4–5 years. In contrast, children who are deaf and hear through cochlear implants (CIs) do not have an opportunity to experience normal, binaural acoustic hearing early in life. These children may function by having to utilize auditory cues that are degraded with regard to numerous stimulus features. In recent years there has been a notable increase in the number of children receiving bilateral CIs, and evidence suggests that while having two CIs helps them function better than when listening through a single CI, they generally perform worse than their NH peers. This paper reviews some of the recent work on bilaterally implanted children. The focus is on measures of spatial hearing, including sound localization, release from masking for speech understanding in noise and binaural sensitivity using research processors. Data from behavioral and electrophysiological studies are included, with a focus on the recent work of the authors and their collaborators. The effects of auditory plasticity and deprivation on the emergence of binaural and spatial hearing are discussed along with evidence for reorganized processing from both behavioral and electrophysiological studies. The consequences of both unilateral and bilateral auditory deprivation during development suggest that the relevant set of issues is highly complex with regard to successes and the limitations experienced by children receiving bilateral cochlear implants. PMID:26828740
ERIC Educational Resources Information Center
Pyschny, Verena; Landwehr, Markus; Hahn, Moritz; Lang-Roth, Ruth; Walger, Martin; Meister, Hartmut
2014-01-01
Purpose: The objective of the study was to investigate the influence of noise (energetic) and speech (energetic plus informational) maskers on the head shadow (HS), squelch (SQ), and binaural summation (SU) effect in bilateral and bimodal cochlear implant (CI) users. Method: Speech recognition was measured in the presence of either a competing…
Churchill, Tyler H; Kan, Alan; Goupell, Matthew J; Litovsky, Ruth Y
2014-09-01
Most contemporary cochlear implant (CI) processing strategies discard acoustic temporal fine structure (TFS) information, and this may contribute to the observed deficits in bilateral CI listeners' ability to localize sounds when compared to normal hearing listeners. Additionally, for best speech envelope representation, most contemporary speech processing strategies use high-rate carriers (≥900 Hz) that exceed the limit for interaural pulse timing to provide useful binaural information. Many bilateral CI listeners are sensitive to interaural time differences (ITDs) in low-rate (<300 Hz) constant-amplitude pulse trains. This study explored the trade-off between superior speech temporal envelope representation with high-rate carriers and binaural pulse timing sensitivity with low-rate carriers. The effects of carrier pulse rate and pulse timing on ITD discrimination, ITD lateralization, and speech recognition in quiet were examined in eight bilateral CI listeners. Stimuli consisted of speech tokens processed at different electrical stimulation rates, and pulse timings that either preserved or did not preserve acoustic TFS cues. Results showed that CI listeners were able to use low-rate pulse timing cues derived from acoustic TFS when presented redundantly on multiple electrodes for ITD discrimination and lateralization of speech stimuli.
Hess, Christi; Zettler-Greeley, Cynthia; Godar, Shelly P; Ellis-Weismer, Susan; Litovsky, Ruth Y
2014-01-01
Growing evidence suggests that children who are deaf and use cochlear implants (CIs) can communicate effectively using spoken language. Research has reported that age of implantation and length of experience with the CI play an important role in a predicting a child's linguistic development. In recent years, the increase in the number of children receiving bilateral CIs (BiCIs) has led to interest in new variables that may also influence the development of hearing, speech, and language abilities, such as length of bilateral listening experience and the length of time between the implantation of the two CIs. One goal of the present study was to determine how a cohort of children with BiCIs performed on standardized measures of language and nonverbal cognition. This study examined the relationship between performance on language and nonverbal intelligence quotient (IQ) tests and the ages at implantation of the first CI and second CI. This study also examined whether early bilateral activation is related to better language scores. Children with BiCIs (n = 39; ages 4 to 9 years) were tested on two standardized measures, the Test of Language Development and the Leiter International Performance Scale-Revised, to evaluate their expressive/receptive language skills and nonverbal IQ/memory. Hierarchical regression analyses were used to evaluate whether BiCI hearing experience predicts language performance. While large intersubject variability existed, on average, almost all the children with BiCIs scored within or above normal limits on measures of nonverbal cognition. Expressive and receptive language scores were highly variable, less likely to be above the normative mean, and did not correlate with Length of first CI Use, defined as length of auditory experience with one cochlear implant, or Length of second CI Use, defined as length of auditory experience with two cochlear implants. All children in the present study had BiCIs. Most IQ scores were either at or above that found in the general population of typically hearing children. However, there was greater variability in their performance on a standardized test of expressive and receptive language. This cohort of children, who are mainstreamed in schools at age-appropriate grades, whose mothers' education is high, and whose families' socioecononomic status is high, had, as a group, on average, language scores within the same range as the normative sample of hearing children. Further research identifying the predictors that contribute to the high variability in both expressive and receptive language scores in children with BiCIs will provide useful information that can aid in clinical management and decision making.
Binaural Speech Understanding With Bilateral Cochlear Implants in Reverberation.
Kokkinakis, Kostas
2018-03-08
The purpose of this study was to investigate whether bilateral cochlear implant (CI) listeners who are fitted with clinical processors are able to benefit from binaural advantages under reverberant conditions. Another aim of this contribution was to determine whether the magnitude of each binaural advantage observed inside a highly reverberant environment differs significantly from the magnitude measured in a near-anechoic environment. Ten adults with postlingual deafness who are bilateral CI users fitted with either Nucleus 5 or Nucleus 6 clinical sound processors (Cochlear Corporation) participated in this study. Speech reception thresholds were measured in sound field and 2 different reverberation conditions (0.06 and 0.6 s) as a function of the listening condition (left, right, both) and the noise spatial location (left, front, right). The presence of the binaural effects of head-shadow, squelch, summation, and spatial release from masking in the 2 different reverberation conditions tested was determined using nonparametric statistical analysis. In the bilateral population tested, when the ambient reverberation time was equal to 0.6 s, results indicated strong positive effects of head-shadow and a weaker spatial release from masking advantage, whereas binaural squelch and summation contributed no statistically significant benefit to bilateral performance under this acoustic condition. These findings are consistent with those of previous studies, which have demonstrated that head-shadow yields the most pronounced advantage in noise. The finding that spatial release from masking produced little to almost no benefit in bilateral listeners is consistent with the hypothesis that additive reverberation degrades spatial cues and negatively affects binaural performance. The magnitude of 4 different binaural advantages was measured on the same group of bilateral CI subjects fitted with clinical processors in 2 different reverberation conditions. The results of this work demonstrate the impeding properties of reverberation on binaural speech understanding. In addition, results indicate that CI recipients who struggle in everyday listening environments are also more likely to benefit less in highly reverberant environments from their bilateral processors.
The Relationship Between Intensity Coding and Binaural Sensitivity in Adults With Cochlear Implants.
Todd, Ann E; Goupell, Matthew J; Litovsky, Ruth Y
Many bilateral cochlear implant users show sensitivity to binaural information when stimulation is provided using a pair of synchronized electrodes. However, there is large variability in binaural sensitivity between and within participants across stimulation sites in the cochlea. It was hypothesized that within-participant variability in binaural sensitivity is in part affected by limitations and characteristics of the auditory periphery which may be reflected by monaural hearing performance. The objective of this study was to examine the relationship between monaural and binaural hearing performance within participants with bilateral cochlear implants. Binaural measures included dichotic signal detection and interaural time difference discrimination thresholds. Diotic signal detection thresholds were also measured. Monaural measures included dynamic range and amplitude modulation detection. In addition, loudness growth was compared between ears. Measures were made at three stimulation sites per listener. Greater binaural sensitivity was found with larger dynamic ranges. Poorer interaural time difference discrimination was found with larger difference between comfortable levels of the two ears. In addition, poorer diotic signal detection thresholds were found with larger differences between the dynamic ranges of the two ears. No relationship was found between amplitude modulation detection thresholds or symmetry of loudness growth and the binaural measures. The results suggest that some of the variability in binaural hearing performance within listeners across stimulation sites can be explained by factors nonspecific to binaural processing. The results are consistent with the idea that dynamic range and comfortable levels relate to peripheral neural survival and the width of the excitation pattern which could affect the fidelity with which central binaural nuclei process bilateral inputs.
Yamamoto, Ryosuke; Naito, Yasushi; Tona, Risa; Moroto, Saburo; Tamaya, Rinko; Fujiwara, Keizo; Shinohara, Shogo; Takebayashi, Shinji; Kikuchi, Masahiro; Michida, Tetsuhiko
2017-11-01
An effect of audio-visual (AV) integration is observed when the auditory and visual stimuli are incongruent (the McGurk effect). In general, AV integration is helpful especially in subjects wearing hearing aids or cochlear implants (CIs). However, the influence of AV integration on spoken word recognition in individuals with bilateral CIs (Bi-CIs) has not been fully investigated so far. In this study, we investigated AV integration in children with Bi-CIs. The study sample included thirty one prelingually deafened children who underwent sequential bilateral cochlear implantation. We assessed their responses to congruent and incongruent AV stimuli with three CI-listening modes: only the 1st CI, only the 2nd CI, and Bi-CIs. The responses were assessed in the whole group as well as in two sub-groups: a proficient group (syllable intelligibility ≥80% with the 1st CI) and a non-proficient group (syllable intelligibility < 80% with the 1st CI). We found evidence of the McGurk effect in each of the three CI-listening modes. AV integration responses were observed in a subset of incongruent AV stimuli, and the patterns observed with the 1st CI and with Bi-CIs were similar. In the proficient group, the responses with the 2nd CI were not significantly different from those with the 1st CI whereas in the non-proficient group the responses with the 2nd CI were driven by visual stimuli more than those with the 1st CI. Our results suggested that prelingually deafened Japanese children who underwent sequential bilateral cochlear implantation exhibit AV integration abilities, both in monaural listening as well as in binaural listening. We also observed a higher influence of visual stimuli on speech perception with the 2nd CI in the non-proficient group, suggesting that Bi-CIs listeners with poorer speech recognition rely on visual information more compared to the proficient subjects to compensate for poorer auditory input. Nevertheless, poorer quality auditory input with the 2nd CI did not interfere with AV integration with binaural listening (with Bi-CIs). Overall, the findings of this study might be used to inform future research to identify the best strategies for speech training using AV integration effectively in prelingually deafened children. Copyright © 2017 Elsevier B.V. All rights reserved.
Preserved Acoustic Hearing in Cochlear Implantation Improves Speech Perception
Sheffield, Sterling W.; Jahn, Kelly; Gifford, René H.
2015-01-01
Background With improved surgical techniques and electrode design, an increasing number of cochlear implant (CI) recipients have preserved acoustic hearing in the implanted ear, thereby resulting in bilateral acoustic hearing. There are currently no guidelines, however, for clinicians with respect to audio-metric criteria and the recommendation of amplification in the implanted ear. The acoustic bandwidth necessary to obtain speech perception benefit from acoustic hearing in the implanted ear is unknown. Additionally, it is important to determine if, and in which listening environments, acoustic hearing in both ears provides more benefit than hearing in just one ear, even with limited residual hearing. Purpose The purposes of this study were to (1) determine whether acoustic hearing in an ear with a CI provides as much speech perception benefit as an equivalent bandwidth of acoustic hearing in the non-implanted ear, and (2) determine whether acoustic hearing in both ears provides more benefit than hearing in just one ear. Research Design A repeated-measures, within-participant design was used to compare performance across listening conditions. Study Sample Seven adults with CIs and bilateral residual acoustic hearing (hearing preservation) were recruited for the study. Data Collection and Analysis Consonant-nucleus-consonant word recognition was tested in four conditions: CI alone, CI + acoustic hearing in the nonimplanted ear, CI + acoustic hearing in the implanted ear, and CI + bilateral acoustic hearing. A series of low-pass filters were used to examine the effects of acoustic bandwidth through an insert earphone with amplification. Benefit was defined as the difference among conditions. The benefit of bilateral acoustic hearing was tested in both diffuse and single-source background noise. Results were analyzed using repeated-measures analysis of variance. Results Similar benefit was obtained for equivalent acoustic frequency bandwidth in either ear. Acoustic hearing in the nonimplanted ear provided more benefit than the implanted ear only in the wideband condition, most likely because of better audiometric thresholds (>500 Hz) in the nonimplanted ear. Bilateral acoustic hearing provided more benefit than unilateral hearing in either ear alone, but only in diffuse background noise. Conclusions Results support use of amplification in the implanted ear if residual hearing is present. The benefit of bilateral acoustic hearing (hearing preservation) should not be tested in quiet or with spatially coincident speech and noise, but rather in spatially separated speech and noise (e.g., diffuse background noise). PMID:25690775
Beneficial auditory and cognitive effects of auditory brainstem implantation in children.
Colletti, Liliana
2007-09-01
This preliminary study demonstrates the development of hearing ability and shows that there is a significant improvement in some cognitive parameters related to selective visual/spatial attention and to fluid or multisensory reasoning, in children fitted with auditory brainstem implantation (ABI). The improvement in cognitive paramenters is due to several factors, among which there is certainly, as demonstrated in the literature on a cochlear implants (CIs), the activation of the auditory sensory canal, which was previously absent. The findings of the present study indicate that children with cochlear or cochlear nerve abnormalities with associated cognitive deficits should not be excluded from ABI implantation. The indications for ABI have been extended over the last 10 years to adults with non-tumoral (NT) cochlear or cochlear nerve abnormalities that cannot benefit from CI. We demonstrated that the ABI with surface electrodes may provide sufficient stimulation of the central auditory system in adults for open set speech recognition. These favourable results motivated us to extend ABI indications to children with profound hearing loss who were not candidates for a CI. This study investigated the performances of young deaf children undergoing ABI, in terms of their auditory perceptual development and their non-verbal cognitive abilities. In our department from 2000 to 2006, 24 children aged 14 months to 16 years received an ABI for different tumour and non-tumour diseases. Two children had NF2 tumours. Eighteen children had bilateral cochlear nerve aplasia. In this group, nine children had associated cochlear malformations, two had unilateral facial nerve agenesia and two had combined microtia, aural atresia and middle ear malformations. Four of these children had previously been fitted elsewhere with a CI with no auditory results. One child had bilateral incomplete cochlear partition (type II); one child, who had previously been fitted unsuccessfully elsewhere with a CI, had auditory neuropathy; one child showed total cochlear ossification bilaterally due to meningitis; and one child had profound hearing loss with cochlear fractures after a head injury. Twelve of these children had multiple associated psychomotor handicaps. The retrosigmoid approach was used in all children. Intraoperative electrical auditory brainstem responses (EABRs) and postoperative EABRs and electrical middle latency responses (EMLRs) were performed. Perceptual auditory abilities were evaluated with the Evaluation of Auditory Responses to Speech (EARS) battery - the Listening Progress Profile (LIP), the Meaningful Auditory Integration Scale (MAIS), the Meaningful Use of Speech Scale (MUSS) - and the Category of Auditory Performance (CAP). Cognitive evaluation was performed on seven children using the Leiter International Performance Scale - Revised (LIPS-R) test with the following subtests: Figure ground, Form completion, Sequential order and Repeated pattern. No postoperative complications were observed. All children consistently used their devices for >75% of waking hours and had environmental sound awareness and utterance of words and simple sentences. Their CAP scores ranged from 1 to 7 (average =4); with MAIS they scored 2-97.5% (average =38%); MUSS scores ranged from 5 to 100% (average =49%) and LIP scores from 5 to 100% (average =45%). Owing to associated disabilities, 12 children were given other therapies (e.g. physical therapy and counselling) in addition to speech and aural rehabilitation therapy. Scores for two of the four subtests of LIPS-R in this study increased significantly during the first year of auditory brainstem implant use in all seven children selected for cognitive evaluation.
Cochlear implantation in adults with asymmetric hearing loss.
Firszt, Jill B; Holden, Laura K; Reeder, Ruth M; Cowdrey, Lisa; King, Sarah
2012-01-01
Bilateral severe to profound sensorineural hearing loss is a standard criterion for cochlear implantation. Increasingly, patients are implanted in one ear and continue to use a hearing aid in the nonimplanted ear to improve abilities such as sound localization and speech understanding in noise. Patients with severe to profound hearing loss in one ear and a more moderate hearing loss in the other ear (i.e., asymmetric hearing) are not typically considered candidates for cochlear implantation. Amplification in the poorer ear is often unsuccessful because of limited benefit, restricting the patient to unilateral listening from the better ear alone. The purpose of this study was to determine whether patients with asymmetric hearing loss could benefit from cochlear implantation in the poorer ear with continued use of a hearing aid in the better ear. Ten adults with asymmetric hearing between ears participated. In the poorer ear, all participants met cochlear implant candidacy guidelines; seven had postlingual onset, and three had pre/perilingual onset of severe to profound hearing loss. All had open-set speech recognition in the better-hearing ear. Assessment measures included word and sentence recognition in quiet, sentence recognition in fixed noise (four-talker babble) and in diffuse restaurant noise using an adaptive procedure, localization of word stimuli, and a hearing handicap scale. Participants were evaluated preimplant with hearing aids and postimplant with the implant alone, the hearing aid alone in the better ear, and bimodally (the implant and hearing aid in combination). Postlingual participants were evaluated at 6 mo postimplant, and pre/perilingual participants were evaluated at 6 and 12 mo postimplant. Data analysis compared the following results: (1) the poorer-hearing ear preimplant (with hearing aid) and postimplant (with cochlear implant); (2) the device(s) used for everyday listening pre- and postimplant; and (3) the hearing aid-alone and bimodal listening conditions postimplant. The postlingual participants showed significant improvements in speech recognition after 6 mo cochlear implant use in the poorer ear. Five postlingual participants had a bimodal advantage over the hearing aid-alone condition on at least one test measure. On average, the postlingual participants had significantly improved localization with bimodal input compared with the hearing aid-alone. Only one pre/perilingual participant had open-set speech recognition with the cochlear implant. This participant had better hearing than the other two pre/perilingual participants in both the poorer and better ear. Localization abilities were not significantly different between the bimodal and hearing aid-alone conditions for the pre/perilingual participants. Mean hearing handicap ratings improved postimplant for all participants indicating perceived benefit in everyday life with the addition of the cochlear implant. Patients with asymmetric hearing loss who are not typical cochlear implant candidates can benefit from using a cochlear implant in the poorer ear with continued use of a hearing aid in the better ear. For this group of 10, the 7 postlingually deafened participants showed greater benefits with the cochlear implant than the pre/perilingual participants; however, further study is needed to determine maximum benefit for those with early onset of hearing loss.
BERRETTINI, S.; ARSLAN, E.; BAGGIANI, A.; BURDO, S.; CASSANDRO, E.; CUDA, D.; FILIPO, R.; GIORGI ROSSI, P.; MANCINI, P.; MARTINI, A.; QUARANTA, A.; QUARANTA, N.; TURCHETTI, G.; FORLI, F.
2011-01-01
SUMMARY The aim of Health Technology Assessment (HTA) is to provide decision-makers, distributors and recipients with information on the effectiveness, cost and impact of health technologies. The present study constitutes a subproject within the wider project “Analysis of the impact of professional involvement in evidence generation for the HTA process”, which is part of the strategic programme “Transfer of the results of the research in clinical practice and organisation of healthcare services”, coordinated by Laziosanità – Agency of Public Healthcare of the Lazio Region and AgeNaS (National Agency for Regional Healthcare Services). The objectives of the present subproject (cochlear implants) are as follows: a) to produce a report regarding the health impact of cochlear implants (CI) on their recipients, through a systematic review of literature and extensive selection of relative studies, combining the outcomes with metanalytical techniques. Output: report on the indications of usage in the groups of population for which benefits are controversial; b) to create a registry of patients using cochlear implants. The registry should contain a selection of anagraphic and clinical information relative to patient follow-up in order to assess factors associated with safety and impact on cochlear implant users. This source of information is essential for future observational studies. This was divided into 4 phases: 1st phase: definition of key participants in the assessment process; 2nd phase: definition of methods and timing of “Aims” (definition of the objective); 3rd phase: definition of the methods and times of the “assessment process”, 4th phase: production of the final report. From the analysis of systematic reviews and italian and international guidelines, the Working Group members approved recommendations on the following topics: results after CI in children in relation to age at implantation, bilateral CI in children, CI in deaf children with associated disabilities, CI in adults with advanced age, bilateral CI in adults and CI in adults with pre-lingual deafness. These recommendations have also been evaluated by the Consulting Committee members and approved with minimal suggestions. PMID:22287819
How to quantify binaural hearing in patients with unilateral hearing using hearing implants.
Snik, Ad; Agterberg, Martijn; Bosman, Arjan
2015-01-01
Application of bilateral hearing devices in bilateral hearing loss and unilateral application in unilateral hearing loss (second ear with normal hearing) does not a priori lead to binaural hearing. An overview is presented on several measures of binaural benefits that have been used in patients with unilateral or bilateral deafness using one or two cochlear implants, respectively, and in patients with unilateral or bilateral conductive/mixed hearing loss using one or two percutaneous bone conduction implants (BCDs), respectively. Overall, according to this overview, the most significant and sensitive measure is the benefit in directional hearing. Measures using speech (viz. binaural summation, binaural squelch or use of the head shadow effect) showed minor benefits, except for patients with bilateral conductive/mixed hearing loss using two BCDs. Although less feasible in daily practise, the binaural masking level difference test seems to be a promising option in the assessment of binaural function. © 2015 S. Karger AG, Basel.
Chadha, Neil K; Papsin, Blake C; Jiwani, Salima; Gordon, Karen A
2011-09-01
To measure speech detection in noise performance for children with bilateral cochlear implants (BiCI), to compare performance in children with simultaneous implant versus those with sequential implant, and to compare performance to normal-hearing children. Prospective cohort study. Tertiary academic pediatric center. Children with early-onset bilateral deafness and 2-year BiCI experience, comprising the "sequential" group (>2 yr interimplantation delay, n = 12) and "simultaneous group" (no interimplantation delay, n = 10) and normal-hearing controls (n = 8). Thresholds to speech detection (at 0-degree azimuth) were measured with noise at 0-degree azimuth or ± 90-degree azimuth. Spatial unmasking (SU) as the noise condition changed from 0-degree azimuth to ± 90-degree azimuth and binaural summation advantage (BSA) of 2 over 1 CI. Speech detection in noise was significantly poorer than controls for both BiCI groups (p < 0.0001). However, the SU in the simultaneous group approached levels found in normal controls (7.2 ± 0.6 versus 8.6 ± 0.6 dB, p > 0.05) and was significantly better than that in the sequential group (3.9 ± 0.4 dB, p < 0.05). Spatial unmasking was unaffected by the side of noise presentation in the simultaneous group but, in the sequential group, was significantly better when noise was moved to the second rather than the first implanted ear (4.8 ± 0.5 versus 3.0 ± 0.4 dB, p < 0.05). This was consistent with a larger BSA from the sequential group's second rather than first CI. Children with simultaneously implanted BiCI demonstrated an advantage over children with sequential implant by using spatial cues to improve speech detection in noise.
Results of a prospective surgical audit of bilateral paediatric cochlear implantation in the UK.
Broomfield, Stephen J; Murphy, John; Wild, Dominik C; Emmett, Stevan R; O'Donoghue, Gerard M
2014-09-01
Since being approved in 2009, bilateral simultaneous cochlear implantation (CI) has been the standard treatment for children in the UK who meet the criteria for CI. The aim was to report surgical outcomes of bilateral CI in the UK. Between January 2010 and December 2011, 14 UK CI centres collected data prospectively: demographics, aetiology, use of imaging, device type, surgery duration, use of intra-operative electrophysiology, length of stay, and post-operative complications. 1397 CI procedures in 961 CI recipients were included; 436 bilateral simultaneous, 394 bilateral sequential, and 131 unilateral. The majority (85%) were congenitally deaf. The commonest causes of acquired deafness were meningitis and cytomegalovirus infection. The median age for congenitally deaf bilateral simultaneous CI was 2.2 years, mean surgical duration 4.5 hours. 6.3% surgeries were day case procedures. Eight cases (2.0%) of planned bilateral CI had unilateral surgery. The overall major complication rate was 1.6% (0.9% excluding device failures), including explantation due to infection (0.2%), cerebrospinal fluid leak (0.2%), and meningitis (0.1%). There were no permanent facial nerve palsies and no deaths. Sixty-two (6.5%) immediate minor complications included 12 (1.3%) children with significant vestibular impairment. The complication rate was similar following bilateral CI compared to sequential and unilateral CI, and is comparable to other published series. This prospective multi-centre audit provides evidence that bilateral paediatric CI is a safe procedure in the UK, thus endorsing its role as a major therapeutic intervention in childhood deafness.
Bittar, Roseli Saraiva Moreira; Sato, Eduardo Setsuo; Ribeiro, Douglas Jósimo Silva; Tsuji, Robinson Koji
Cochlear implants are undeniably an effective method for the recovery of hearing function in patients with hearing loss. To describe the preoperative vestibular assessment protocol in subjects who will be submitted to cochlear implants. Our institutional protocol provides the vestibular diagnosis through six simple tests: Romberg and Fukuda tests, assessment for spontaneous nystagmus, Head Impulse Test, evaluation for Head Shaking Nystagmus and caloric test. 21 patients were evaluated with a mean age of 42.75±14.38 years. Only 28% of the sample had all normal test results. The presence of asymmetric vestibular information was documented through the caloric test in 32% of the sample and spontaneous nystagmus was an important clue for the diagnosis. Bilateral vestibular areflexia was present in four subjects, unilateral arreflexia in three and bilateral hyporeflexia in two. The Head Impulse Test was a significant indicator for the diagnosis of areflexia in the tested ear (p=0.0001). The sensitized Romberg test using a foam pad was able to diagnose severe vestibular function impairment (p=0.003). The six clinical tests were able to identify the presence or absence of vestibular function and function asymmetry between the ears of the same individual. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Tsuji, Robinson Koji; Bento, Ricardo Ferreira; de Carvalho, Ana Claudia Martinho; Matas, Carla Gentile
2015-01-01
The purpose of this study was to longitudinally assess the behavioral and electrophysiological hearing changes of a girl inserted in a CI program, who had bilateral profound sensorineural hearing loss and underwent surgery of cochlear implantation with electrode activation at 21 months of age. She was evaluated using the P1 component of Long Latency Auditory Evoked Potential (LLAEP); speech perception tests of the Glendonald Auditory Screening Procedure (GASP); Infant Toddler Meaningful Auditory Integration Scale (IT-MAIS); and Meaningful Use of Speech Scales (MUSS). The study was conducted prior to activation and after three, nine, and 18 months of cochlear implant activation. The results of the LLAEP were compared with data from a hearing child matched by gender and chronological age. The results of the LLAEP of the child with cochlear implant showed gradual decrease in latency of the P1 component after auditory stimulation (172 ms–134 ms). In the GASP, IT-MAIS, and MUSS, gradual development of listening skills and oral language was observed. The values of the LLAEP of the hearing child were expected for chronological age (132 ms–128 ms). The use of different clinical instruments allow a better understanding of the auditory habilitation and rehabilitation process via CI. PMID:26881163
The Relationship Between Intensity Coding and Binaural Sensitivity in Adults With Cochlear Implants
Todd, Ann E.; Goupell, Matthew J.; Litovsky, Ruth Y.
2016-01-01
Objectives Many bilateral cochlear implant users show sensitivity to binaural information when stimulation is provided using a pair of synchronized electrodes. However, there is large variability in binaural sensitivity between and within participants across stimulation sites in the cochlea. It was hypothesized that within-participant variability in binaural sensitivity is in part affected by limitations and characteristics of the auditory periphery which may be reflected by monaural hearing performance. The objective of this study was to examine the relationship between monaural and binaural hearing performance within participants with bilateral cochlear implants. Design Binaural measures included dichotic signal detection and interaural time difference discrimination thresholds. Diotic signal detection thresholds were also measured. Monaural measures included dynamic range and amplitude modulation detection. In addition, loudness growth was compared between ears. Measures were made at three stimulation sites per listener. Results Greater binaural sensitivity was found with larger dynamic ranges. Poorer interaural time difference discrimination was found with larger difference between comfortable levels of the two ears. In addition, poorer diotic signal detection thresholds were found with larger differences between the dynamic ranges of the two ears. No relationship was found between amplitude modulation detection thresholds or symmetry of loudness growth and the binaural measures. Conclusions The results suggest that some of the variability in binaural hearing performance within listeners across stimulation sites can be explained by factors non-specific to binaural processing. The results are consistent with the idea that dynamic range and comfortable levels relate to peripheral neural survival and the width of the excitation pattern which could affect the fidelity with which central binaural nuclei process bilateral inputs. PMID:27787393
Binaural Pitch Fusion in Bilateral Cochlear Implant Users.
Reiss, Lina A J; Fowler, Jennifer R; Hartling, Curtis L; Oh, Yonghee
Binaural pitch fusion is the fusion of stimuli that evoke different pitches between the ears into a single auditory image. Individuals who use hearing aids or bimodal cochlear implants (CIs) experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3-4 octaves are fused across ears, leading to spectral averaging and speech perception interference. The goal of this study was to determine if adult bilateral CI users also experience broad binaural pitch fusion. Stimuli were pulse trains delivered to individual electrodes. Fusion ranges were measured using simultaneous, dichotic presentation of reference and comparison stimuli in opposite ears, and varying the comparison stimulus to find the range that fused with the reference stimulus. Bilateral CI listeners had binaural pitch fusion ranges varying from 0 to 12 mm (average 6.1 ± 3.9 mm), where 12 mm indicates fusion over all electrodes in the array. No significant correlations of fusion range were observed with any subject factors related to age, hearing loss history, or hearing device history, or with any electrode factors including interaural electrode pitch mismatch, pitch match bandwidth, or within-ear electrode discrimination abilities. Bilateral CI listeners have abnormally broad fusion, similar to hearing aid and bimodal CI listeners. This broad fusion may explain the variability of binaural benefits for speech perception in quiet and in noise in bilateral CI users.
Firszt, Jill B; Reeder, Ruth M; Holden, Laura K
At a minimum, unilateral hearing loss (UHL) impairs sound localization ability and understanding speech in noisy environments, particularly if the loss is severe to profound. Accompanying the numerous negative consequences of UHL is considerable unexplained individual variability in the magnitude of its effects. Identification of covariables that affect outcome and contribute to variability in UHLs could augment counseling, treatment options, and rehabilitation. Cochlear implantation as a treatment for UHL is on the rise yet little is known about factors that could impact performance or whether there is a group at risk for poor cochlear implant outcomes when hearing is near-normal in one ear. The overall goal of our research is to investigate the range and source of variability in speech recognition in noise and localization among individuals with severe to profound UHL and thereby help determine factors relevant to decisions regarding cochlear implantation in this population. The present study evaluated adults with severe to profound UHL and adults with bilateral normal hearing. Measures included adaptive sentence understanding in diffuse restaurant noise, localization, roving-source speech recognition (words from 1 of 15 speakers in a 140° arc), and an adaptive speech-reception threshold psychoacoustic task with varied noise types and noise-source locations. There were three age-sex-matched groups: UHL (severe to profound hearing loss in one ear and normal hearing in the contralateral ear), normal hearing listening bilaterally, and normal hearing listening unilaterally. Although the normal-hearing-bilateral group scored significantly better and had less performance variability than UHLs on all measures, some UHL participants scored within the range of the normal-hearing-bilateral group on all measures. The normal-hearing participants listening unilaterally had better monosyllabic word understanding than UHLs for words presented on the blocked/deaf side but not the open/hearing side. In contrast, UHLs localized better than the normal-hearing unilateral listeners for stimuli on the open/hearing side but not the blocked/deaf side. This suggests that UHLs had learned strategies for improved localization on the side of the intact ear. The UHL and unilateral normal-hearing participant groups were not significantly different for speech in noise measures. UHL participants with childhood rather than recent hearing loss onset localized significantly better; however, these two groups did not differ for speech recognition in noise. Age at onset in UHL adults appears to affect localization ability differently than understanding speech in noise. Hearing thresholds were significantly correlated with speech recognition for UHL participants but not the other two groups. Auditory abilities of UHLs varied widely and could be explained only in part by hearing threshold levels. Age at onset and length of hearing loss influenced performance on some, but not all measures. Results support the need for a revised and diverse set of clinical measures, including sound localization, understanding speech in varied environments, and careful consideration of functional abilities as individuals with severe to profound UHL are being considered potential cochlear implant candidates.
Buechner, Andreas; Dyballa, Karl-Heinz; Hehrmann, Phillipp; Fredelake, Stefan; Lenarz, Thomas
2014-01-01
Objective To investigate the performance of monaural and binaural beamforming technology with an additional noise reduction algorithm, in cochlear implant recipients. Method This experimental study was conducted as a single subject repeated measures design within a large German cochlear implant centre. Twelve experienced users of an Advanced Bionics HiRes90K or CII implant with a Harmony speech processor were enrolled. The cochlear implant processor of each subject was connected to one of two bilaterally placed state-of-the-art hearing aids (Phonak Ambra) providing three alternative directional processing options: an omnidirectional setting, an adaptive monaural beamformer, and a binaural beamformer. A further noise reduction algorithm (ClearVoice) was applied to the signal on the cochlear implant processor itself. The speech signal was presented from 0° and speech shaped noise presented from loudspeakers placed at ±70°, ±135° and 180°. The Oldenburg sentence test was used to determine the signal-to-noise ratio at which subjects scored 50% correct. Results Both the adaptive and binaural beamformer were significantly better than the omnidirectional condition (5.3 dB±1.2 dB and 7.1 dB±1.6 dB (p<0.001) respectively). The best score was achieved with the binaural beamformer in combination with the ClearVoice noise reduction algorithm, with a significant improvement in SRT of 7.9 dB±2.4 dB (p<0.001) over the omnidirectional alone condition. Conclusions The study showed that the binaural beamformer implemented in the Phonak Ambra hearing aid could be used in conjunction with a Harmony speech processor to produce substantial average improvements in SRT of 7.1 dB. The monaural, adaptive beamformer provided an averaged SRT improvement of 5.3 dB. PMID:24755864
Koka, Kanthaiah; Saoji, Aniket A; Attias, Joseph; Litvak, Leonid M
2017-01-01
Although, cochlear implants (CI) traditionally have been used to treat individuals with bilateral profound sensorineural hearing loss, a recent trend is to implant individuals with residual low-frequency hearing. Notably, many of these individuals demonstrate an air-bone gap (ABG) in low-frequency, pure-tone thresholds following implantation. An ABG is the difference between audiometric thresholds measured using air conduction (AC) and bone conduction (BC) stimulation. Although, behavioral AC thresholds are straightforward to assess, BC thresholds can be difficult to measure in individuals with severe-to-profound hearing loss because of vibrotactile responses to high-level, low-frequency stimulation and the potential contribution of hearing in the contralateral ear. Because of these technical barriers to measuring behavioral BC thresholds in implanted patients with residual hearing, it would be helpful to have an objective method for determining ABG. This study evaluated an innovative technique for measuring electrocochleographic (ECochG) responses using the cochlear microphonic (CM) response to assess AC and BC thresholds in implanted patients with residual hearing. Results showed high correlations between CM thresholds and behavioral audiograms for AC and BC conditions, thereby demonstrating the feasibility of using ECochG as an objective tool for quantifying ABG in CI recipients.
Van Hoesel, Richard; Ramsden, Richard; Odriscoll, Martin
2002-04-01
To characterize some of the benefits available from using two cochlear implants compared with just one, sound-direction identification (ID) abilities, sensitivity to interaural time delays (ITDs) and speech intelligibility in noise were measured for a bilateral multi-channel cochlear implant user. Sound-direction ID in the horizontal plane was tested with a bilateral cochlear implant user. The subject was tested both unilaterally and bilaterally using two independent behind-the-ear ESPRIT (Cochlear Ltd.) processors, as well as bilaterally using custom research processors. Pink noise bursts were presented using an 11-loudspeaker array spanning the subject's frontal 180 degrees arc in an anechoic room. After each burst, the subject was asked to identify which loudspeaker had produced the sound. No explicit training, and no feedback were given. Presentation levels were nominally at 70 dB SPL, except for a repeat experiment using the clinical devices where the presentation levels were reduced to 60 dB SPL to avoid activation of the devices' automatic gain control (AGC) circuits. Overall presentation levels were randomly varied by +/- 3 dB. For the research processor, a "low-update-rate" and a "high-update-rate" strategy were tested. Direct measurements of ITD just noticeable differences (JNDs) were made using a 3 AFC paradigm targeting 70% correct performance on the psychometric function. Stimuli included simple, low-rate electrical pulse trains as well as high-rate pulse trains modulated at 100 Hz. Speech data comparing monaural and binaural performance in noise were also collected with both low, and high update-rate strategies on the research processors. Open-set sentences were presented from directly in front of the subject and competing multi-talker babble noise was presented from the same loudspeaker, or from a loudspeaker placed 90 degrees to the left or right of the subject. For the sound-direction ID task, monaural performance using the clinical devices showed large mean absolute errors of 81 degrees and 73 degrees, with standard deviations (averaged across all 11 loud-speakers) of 10 degrees and 17 degrees, for left and right ears, respectively. Fore bilateral device use at a presentation level of 70 dB SPL, the mean error improved to about 16 degrees with an average standard deviation of 18 degrees. When the presentation level was decreased to 60 dB SPL to avoid activation of the automatic gain control (AGC) circuits in the clinical processors, the mean response error improved further to 8 degrees with a standard deviation of 13 degrees. Further tests with the custom research processors, which had a higher stimulation rate and did not include AGCs, showed comparable response errors: around 8 or 9 degrees and a standard deviation of about 11 degrees for both update rates. The best ITD JNDs measured for this subject were between 350 to 400 microsec for simple low-rate pulse trains. Speech results showed a substantial headshadow advantage for bilateral device use when speech and noise were spatially separated, but little evidence of binaural unmasking. For spatially coincident speech and noise, listening with both ears showed similar results to listening with either side alone when loudness summation was compensated for. No significant differences were observed between binaural results for high and low update-rates in any test configuration. Only for monaural listening in one test configuration did the high rate show a small significant improvement over the low rate. Results show that even if interaural time delay cues are not well coded or perceived, bilateral implants can offer important advantages, both for speech in noise as well as for sound-direction identification.
Daneshi, Ahmad; Mirsalehi, Marjan; Hashemi, Seyed Basir; Ajalloueyan, Mohammad; Rajati, Mohsen; Ghasemi, Mohammad Mahdi; Emamdjomeh, Hesamaldin; Asghari, Alimohamad; Mohammadi, Shabahang; Mohseni, Mohammad; Mohebbi, Saleh; Farhadi, Mohammad
2018-05-01
To evaluate the auditory performance and speech production outcome in children with auditory neuropathy spectrum disorder (ANSD). The effect of age on the outcomes of the surgery at the time of implantation was also evaluated. Cochlear implantation was performed in 136 children with bilateral severe-to- profound hearing loss due to ANSD, at four tertiary academic centers. The patients were divided into two groups based on the age at the time of implantation; Group I: Children ≤24 months, and Group II: subjects >24 months. The categories of auditory performance (CAP) and speech intelligibility rating (SIR) scores were evaluated after the first and second years of implantation. The differences between the CAP and SIR scores in the two groups were assessed. The median CAP scores improved significantly after the cochlear implantation in all the patients (p value < 0.001). The improvement in the CAP scores during the first year in Group II was greater than Group I (p value: 0.007), but the improvement in CAP scores tended to be significantly higher in patients who were implanted at ≤24 months (p value < 0.001). There was no significant difference between two groups in SIR scores at first-year and second-year follow-ups. The evaluation of the SIR improvement revealed significantly higher values for Group I during the second-year follow-up (p value: 0.003). The auditory performance and speech production skills of the children with ANSD improved significantly after cochlear implantation, and this improvement was affected by age at the time of implantation. Copyright © 2018 Elsevier B.V. All rights reserved.
Deshpande, Aniruddha K; Tan, Lirong; Lu, Long J; Altaye, Mekibib; Holland, Scott K
2018-05-01
The trends in cochlear implantation candidacy and benefit have changed rapidly in the last two decades. It is now widely accepted that early implantation leads to better postimplant outcomes. Although some generalizations can be made about postimplant auditory and language performance, neural mechanisms need to be studied to predict individual prognosis. The aim of this study was to use functional magnetic resonance imaging (fMRI) to identify preimplant neuroimaging biomarkers that predict children's postimplant auditory and language outcomes as measured by parental observation/reports. This is a pre-post correlational measures study. Twelve possible cochlear implant candidates with bilateral severe to profound hearing loss were recruited via referrals for a clinical magnetic resonance imaging to ensure structural integrity of the auditory nerve for implantation. Participants underwent cochlear implantation at a mean age of 19.4 mo. All children used the advanced combination encoder strategy (ACE, Cochlear Corporation™, Nucleus ® Freedom cochlear implants). Three participants received an implant in the right ear; one in the left ear whereas eight participants received bilateral implants. Participants' preimplant neuronal activation in response to two auditory stimuli was studied using an event-related fMRI method. Blood oxygen level dependent contrast maps were calculated for speech and noise stimuli. The general linear model was used to create z-maps. The Auditory Skills Checklist (ASC) and the SKI-HI Language Development Scale (SKI-HI LDS) were administered to the parents 2 yr after implantation. A nonparametric correlation analysis was implemented between preimplant fMRI activation and postimplant auditory and language outcomes based on ASC and SKI-HI LDS. Statistical Parametric Mapping software was used to create regression maps between fMRI activation and scores on the aforementioned tests. Regression maps were overlaid on the Imaging Research Center infant template and visualized in MRIcro. Regression maps revealed two clusters of brain activation for the speech versus silence contrast and five clusters for the noise versus silence contrast that were significantly correlated with the parental reports. These clusters included auditory and extra-auditory regions such as the middle temporal gyrus, supramarginal gyrus, precuneus, cingulate gyrus, middle frontal gyrus, subgyral, and middle occipital gyrus. Both positive and negative correlations were observed. Correlation values for the different clusters ranged from -0.90 to 0.95 and were significant at a corrected p value of <0.05. Correlations suggest that postimplant performance may be predicted by activation in specific brain regions. The results of the present study suggest that (1) fMRI can be used to identify neuroimaging biomarkers of auditory and language performance before implantation and (2) activation in certain brain regions may be predictive of postimplant auditory and language performance as measured by parental observation/reports. American Academy of Audiology.
Morita, Shinya; Fujiwara, Keishi; Fukuda, Atsushi; Fukuda, Satoshi; Nishio, Shin-Ya; Kitoh, Ryosuke; Hato, Naohito; Ikezono, Tetsuo; Ishikawa, Kotaro; Kaga, Kimitaka; Matsubara, Atsushi; Matsunaga, Tatsuo; Murata, Takaaki; Naito, Yasushi; Nishizaki, Kazunori; Ogawa, Kaoru; Sano, Hajime; Sato, Hiroaki; Sone, Michihiko; Suzuki, Mikio; Takahashi, Haruo; Tono, Tetsuya; Yamashita, Hiroshi; Yamasoba, Tatsuya; Usami, Shin-Ichi
2017-01-01
The majority of hearing loss due to mumps presents as unilateral profound sensorineural hearing loss, which is refractory to treatment. In rare cases of bilateral total deafness, cochlear implants were beneficial for speech perception. Vaccination against mumps is recommended to prevent mumps-associated hearing loss. The objective of this study is to investigate the clinical characteristics of hearing loss due to mumps and to evaluate hearing outcomes. The clinical parameters were analyzed under a retrospective multi-institutional study design in patients diagnosed with hearing loss due to mumps at the Otolaryngology departments of 19 hospitals between 1987 and 2016. Sixty-seven patients with hearing loss due to mumps were enrolled. The study population consisted of 35 males and 32 females, ranging in age from 1 to 54, with a median age of 9.5 years. Sixty-three patients presented with unilateral, and 4 with bilateral hearing loss. Profound hearing loss was observed in 65 ears. Only one ear with severe hearing loss showed complete recovery. Four patients with bilateral hearing loss received cochlear implant surgery. Most of the patients with hearing loss due to mumps had no history of vaccination.
Binaural unmasking with multiple adjacent masking electrodes in bilateral cochlear implant users
Lu, Thomas; Litovsky, Ruth; Zeng, Fan-Gang
2011-01-01
Bilateral cochlear implant (BiCI) users gain an advantage in noisy situations from a second implant, but their bilateral performance falls short of normal hearing listeners. Channel interactions due to overlapping electrical fields between electrodes can impair speech perception, but its role in limiting binaural hearing performance has not been well characterized. To address the issue, binaural masking level differences (BMLD) for a 125 Hz tone in narrowband noise were measured using a pair of pitch-matched electrodes while simultaneously presenting the same masking noise to adjacent electrodes, representing a more realistic stimulation condition compared to prior studies that used only a single electrode pair. For five subjects, BMLDs averaged 8.9 ± 1.0 dB (mean ± s.e.) in single electrode pairs but dropped to 2.1 ± 0.4 dB when presenting noise on adjacent masking electrodes, demonstrating a negative impact of the additional maskers. Removing the masking noise from only the pitch-matched electrode pair not only lowered thresholds but also resulted in smaller BMLDs. The degree of channel interaction estimated from auditory nerve evoked potentials in three subjects was significantly and negatively correlated with BMLD. The data suggest that if the amount of channel interactions can be reduced, BiCI users may experience some performance improvements related to binaural hearing. PMID:21682415
Rader, Tobias; Fastl, Hugo; Baumann, Uwe
2013-01-01
The aim of the study was to measure and compare speech perception in users of electric-acoustic stimulation (EAS) supported by a hearing aid in the unimplanted ear and in bilateral cochlear implant (CI) users under different noise and sound field conditions. Gap listening was assessed by comparing performance in unmodulated and modulated Comité Consultatif International Téléphonique et Télégraphique (CCITT) noise conditions, and binaural interaction was investigated by comparing single source and multisource sound fields. Speech perception in noise was measured using a closed-set sentence test (Oldenburg Sentence Test, OLSA) in a multisource noise field (MSNF) consisting of a four-loudspeaker array with independent noise sources and a single source in frontal position (S0N0). Speech simulating noise (Fastl-noise), CCITT-noise (continuous), and OLSA-noise (pseudo continuous) served as noise sources with different temporal patterns. Speech tests were performed in two groups of subjects who were using either EAS (n = 12) or bilateral CIs (n = 10). All subjects in the EAS group were fitted with a high-power hearing aid in the opposite ear (bimodal EAS). The average group score on monosyllable in quiet was 68.8% (EAS) and 80.5% (bilateral CI). A group of 22 listeners with normal hearing served as controls to compare and evaluate potential gap listening effects in implanted patients. Average speech reception thresholds in the EAS group were significantly lower than those for the bilateral CI group in all test conditions (CCITT 6.1 dB, p = 0.001; Fastl-noise 5.4 dB, p < 0.01; Oldenburg-(OL)-noise 1.6 dB, p < 0.05). Bilateral CI and EAS user groups showed a significant improvement of 4.3 dB (p = 0.004) and 5.4 dB (p = 0.002) between S0N0 and MSNF sound field conditions respectively, which signifies advantages caused by bilateral interaction in both groups. Performance in the control group showed a significant gap listening effect with a difference of 6.5 dB between modulated and unmodulated noise in S0N0, and a difference of 3.0 dB in MSNF. The ability to "glimpse" into short temporal masker gaps was absent in both groups of implanted subjects. Combined EAS in one ear supported by a hearing aid on the contralateral ear provided significantly improved speech perception compared with bilateral cochlear implantation. Although the scores for monosyllable words in quiet were higher in the bilateral CI group, the EAS group performed better in different noise and sound field conditions. Furthermore, the results indicated that binaural interaction between EAS in one ear and residual acoustic hearing in the opposite ear enhances speech perception in complex noise situations. Both bilateral CI and bimodal EAS users did not benefit from short temporal masker gaps, therefore the better performance of the EAS group in modulated noise conditions could be explained by the improved transmission of fundamental frequency cues in the lower-frequency region of acoustic hearing, which might foster the grouping of auditory objects.
Sheffield, Benjamin M; Schuchman, Gerald; Bernstein, Joshua G W
2015-01-01
As cochlear implant (CI) acceptance increases and candidacy criteria are expanded, these devices are increasingly recommended for individuals with less than profound hearing loss. As a result, many individuals who receive a CI also retain acoustic hearing, often in the low frequencies, in the nonimplanted ear (i.e., bimodal hearing) and in some cases in the implanted ear (i.e., hybrid hearing) which can enhance the performance achieved by the CI alone. However, guidelines for clinical decisions pertaining to cochlear implantation are largely based on expectations for postsurgical speech-reception performance with the CI alone in auditory-only conditions. A more comprehensive prediction of postimplant performance would include the expected effects of residual acoustic hearing and visual cues on speech understanding. An evaluation of auditory-visual performance might be particularly important because of the complementary interaction between the speech information relayed by visual cues and that contained in the low-frequency auditory signal. The goal of this study was to characterize the benefit provided by residual acoustic hearing to consonant identification under auditory-alone and auditory-visual conditions for CI users. Additional information regarding the expected role of residual hearing in overall communication performance by a CI listener could potentially lead to more informed decisions regarding cochlear implantation, particularly with respect to recommendations for or against bilateral implantation for an individual who is functioning bimodally. Eleven adults 23 to 75 years old with a unilateral CI and air-conduction thresholds in the nonimplanted ear equal to or better than 80 dB HL for at least one octave frequency between 250 and 1000 Hz participated in this study. Consonant identification was measured for conditions involving combinations of electric hearing (via the CI), acoustic hearing (via the nonimplanted ear), and speechreading (visual cues). The results suggest that the benefit to CI consonant-identification performance provided by the residual acoustic hearing is even greater when visual cues are also present. An analysis of consonant confusions suggests that this is because the voicing cues provided by the residual acoustic hearing are highly complementary with the mainly place-of-articulation cues provided by the visual stimulus. These findings highlight the need for a comprehensive prediction of trimodal (acoustic, electric, and visual) postimplant speech-reception performance to inform implantation decisions. The increased influence of residual acoustic hearing under auditory-visual conditions should be taken into account when considering surgical procedures or devices that are intended to preserve acoustic hearing in the implanted ear. This is particularly relevant when evaluating the candidacy of a current bimodal CI user for a second CI (i.e., bilateral implantation). Although recent developments in CI technology and surgical techniques have increased the likelihood of preserving residual acoustic hearing, preservation cannot be guaranteed in each individual case. Therefore, the potential gain to be derived from bilateral implantation needs to be weighed against the possible loss of the benefit provided by residual acoustic hearing.
Arndt, Susan; Aschendorff, Antje; Laszig, Roland; Wesarg, Thomas
2016-01-01
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPD is highly desirable. In this study, we compared two coding strategies in BiCI users provided with CI systems from MED-EL (Innsbruck, Austria). The CI systems were bilaterally programmed either with the fine structure processing strategy FS4 or with the constant rate strategy high definition continuous interleaved sampling (HDCIS). Familiarization periods between 6 and 12 weeks were considered. The effect of IPD was measured in two types of experiments: (a) IPD detection thresholds with tonal signals addressing mainly one apical interaural electrode pair and (b) with speech in noise in terms of binaural speech intelligibility level differences (BILD) addressing multiple electrodes bilaterally. The results in (a) showed improved IPD detection thresholds with FS4 compared with HDCIS in four out of the seven BiCI users. In contrast, 12 BiCI users in (b) showed similar BILD with FS4 (0.6 ± 1.9 dB) and HDCIS (0.5 ± 2.0 dB). However, no correlation between results in (a) and (b) both obtained with FS4 was found. In conclusion, the degree of IPD sensitivity determined on an apical interaural electrode pair was not an indicator for BILD based on bilateral multielectrode stimulation. PMID:27659487
Zirn, Stefan; Arndt, Susan; Aschendorff, Antje; Laszig, Roland; Wesarg, Thomas
2016-09-22
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPD is highly desirable. In this study, we compared two coding strategies in BiCI users provided with CI systems from MED-EL (Innsbruck, Austria). The CI systems were bilaterally programmed either with the fine structure processing strategy FS4 or with the constant rate strategy high definition continuous interleaved sampling (HDCIS). Familiarization periods between 6 and 12 weeks were considered. The effect of IPD was measured in two types of experiments: (a) IPD detection thresholds with tonal signals addressing mainly one apical interaural electrode pair and (b) with speech in noise in terms of binaural speech intelligibility level differences (BILD) addressing multiple electrodes bilaterally. The results in (a) showed improved IPD detection thresholds with FS4 compared with HDCIS in four out of the seven BiCI users. In contrast, 12 BiCI users in (b) showed similar BILD with FS4 (0.6 ± 1.9 dB) and HDCIS (0.5 ± 2.0 dB). However, no correlation between results in (a) and (b) both obtained with FS4 was found. In conclusion, the degree of IPD sensitivity determined on an apical interaural electrode pair was not an indicator for BILD based on bilateral multielectrode stimulation. © The Author(s) 2016.
Hoskison, Emma; Mitchell, Scott; Coulson, Chris
2017-07-01
Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.
Growing up with a cochlear implant: education, vocation, and affiliation.
Spencer, Linda J; Tomblin, J Bruce; Gantz, Bruce J
2012-01-01
The long-term educational/vocational, affiliation, and quality-of-life outcomes of the first and second cohorts of children with bilateral, profound hearing loss who received cochlear implants under a large National Institutes of Health-funded study was investigated in 41 of 61 eligible participants. Educational and vocational outcomes were collected from user survey data. Affiliation and quality-of-life data were collected from the Satisfaction-with-Life scale and the Deaf Identity Scale. Qualitative results indicated that compared with their hearing, adult-age peers, this group obtained high educational achievement, and they reported a very high satisfaction of life. With respect to forming an identity in these first 2 cohorts of cochlear implant users, we found that most of the individuals endorsed a dual identity, which indicates they feel just as comfortable with Deaf individuals as they do with hearing individuals. Quantitative results revealed a significant relationship between ability to hear and ability to speak, in addition to consistency of device use. Additional relationships were found between mother's and the individual's educational statuses, hearing scores, and communication system used. Younger individuals scored higher on satisfaction-with-life measures, and they also tended to endorse a dual identity more often. Taken together, these findings diminish concerns that profoundly deaf individuals growing up with cochlear implants will become culturally bereft and unable to function in the hearing world.
Rich, Shanit; Levinger, Miriam; Werner, Shirli; Adelman, Cahtia
2013-08-01
The cochlear implant has revolutionized functioning with severe-to-profound sensori-neural loss. A deaf child implanted at an early age with good habilitation may have good language abilities and function well in daily life. As the implanted child grows up, managing in the world of hearing people may become more complex. During adolescence, the teenager copes with many issues, including identity, socialization with the peer group, and managing in the school setting. These issues may be even more challenging for the adolescents using a cochlear implant. This study was designed to shed light on how adolescents with cochlear implants experience coping with the issues mentioned. Twelve teenagers (14-18 years old), fairly similar to the entire adolescent implanted population at the center at which the study was conducted, participated in the study. They had been unilaterally or bilaterally implanted at differing ages. The participants filled out a questionnaire dealing with their functioning in the educational setting, their social preferences and functioning, and their identity as hearing or deaf. The results were analyzed using the principles of thematic analysis. At school, some reported better achievements than others but they all expressed some difficulty functioning in class mainly in situations involving several speakers. From a social point of view, some reported a preference for association with normal hearing peers, whereas others favored hard-of-hearing friends, and one had no preference. Of those who touched on the topic of self-identity, one referred to herself as deaf, eight defined themselves as hard-of-hearing, and two consider themselves hearing. From the responses of these teenagers, it is clear that adolescents with cochlear implants are a heterogeneous group. Parents and teachers should be aware that adolescents with implants, even when successful academically, may experience difficulties in the classroom setting. Most of the participants in this study learning in a mainstream setting, preferred social relationships with hearing peers (to hard of hearing/deaf). The responses of these adolescents with cochlear implants support the conjecture that they have both a hearing identity and a deaf identity, which may be expressed at varying intensities depending on the situation at the time. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Enduring Advantages of Early Cochlear Implantation for Spoken Language Development
Geers, Ann E.; Nicholas, Johanna G.
2013-01-01
Purpose To determine whether the precise age of implantation (AOI) remains an important predictor of spoken language outcomes in later childhood for those who received a cochlear implant (CI) between 12–38 months of age. Relative advantages of receiving a bilateral CI after age 4.5, better pre-CI aided hearing, and longer CI experience were also examined. Method Sixty children participated in a prospective longitudinal study of outcomes at 4.5 and 10.5 years of age. Twenty-nine children received a sequential second CI. Test scores were compared to normative samples of hearing age-mates and predictors of outcomes identified. Results Standard scores on language tests at 10.5 years of age remained significantly correlated with age of first cochlear implantation. Scores were not associated with receipt of a second, sequentially-acquired CI. Significantly higher scores were achieved for vocabulary as compared with overall language, a finding not evident when the children were tested at younger ages. Conclusion Age-appropriate spoken language skills continued to be more likely with younger AOI, even after an average of 8.6 years of additional CI use. Receipt of a second implant between ages 4–10 years and longer duration of device use did not provide significant added benefit. PMID:23275406
Spatial Release From Masking in 2-Year-Olds With Normal Hearing and With Bilateral Cochlear Implants
Hess, Christi L.; Misurelli, Sara M.; Litovsky, Ruth Y.
2018-01-01
This study evaluated spatial release from masking (SRM) in 2- to 3-year-old children who are deaf and were implanted with bilateral cochlear implants (BiCIs), and in age-matched normal-hearing (NH) toddlers. Here, we examined whether early activation of bilateral hearing has the potential to promote SRM that is similar to age-matched NH children. Listeners were 13 NH toddlers and 13 toddlers with BiCIs, ages 27 to 36 months. Speech reception thresholds (SRTs) were measured for target speech in front (0°) and for competitors that were either Colocated in front (0°) or Separated toward the right (+90°). SRM was computed as the difference between SRTs in the front versus in the asymmetrical condition. Results show that SRTs were higher in the BiCI than NH group in all conditions. Both groups had higher SRTs in the Colocated and Separated conditions compared with Quiet, indicating masking. SRM was significant only in the NH group. In the BiCI group, the group effect of SRM was not significant, likely limited by the small sample size; however, all but two children had SRM values within the NH range. This work shows that to some extent, the ability to use spatial cues for source segregation develops by age 2 to 3 in NH children and is attainable in most of the children in the BiCI group. There is potential for the paradigm used here to be used in clinical settings to evaluate outcomes of bilateral hearing in very young children. PMID:29761735
Zeitler, Daniel M; Dorman, Michael F; Natale, Sarah J; Loiselle, Louise; Yost, William A; Gifford, Rene H
2015-09-01
To assess improvements in sound source localization and speech understanding in complex listening environments after unilateral cochlear implantation for single-sided deafness (SSD). Nonrandomized, open, prospective case series. Tertiary referral center. Nine subjects with a unilateral cochlear implant (CI) for SSD (SSD-CI) were tested. Reference groups for the task of sound source localization included young (n = 45) and older (n = 12) normal-hearing (NH) subjects and 27 bilateral CI (BCI) subjects. Unilateral cochlear implantation. Sound source localization was tested with 13 loudspeakers in a 180 arc in front of the subject. Speech understanding was tested with the subject seated in an 8-loudspeaker sound system arrayed in a 360-degree pattern. Directionally appropriate noise, originally recorded in a restaurant, was played from each loudspeaker. Speech understanding in noise was tested using the Azbio sentence test and sound source localization quantified using root mean square error. All CI subjects showed poorer-than-normal sound source localization. SSD-CI subjects showed a bimodal distribution of scores: six subjects had scores near the mean of those obtained by BCI subjects, whereas three had scores just outside the 95th percentile of NH listeners. Speech understanding improved significantly in the restaurant environment when the signal was presented to the side of the CI. Cochlear implantation for SSD can offer improved speech understanding in complex listening environments and improved sound source localization in both children and adults. On tasks of sound source localization, SSD-CI patients typically perform as well as BCI patients and, in some cases, achieve scores at the upper boundary of normal performance.
Carlson, Matthew L; Sladen, Douglas P; Gurgel, Richard K; Tombers, Nicole M; Lohse, Christine M; Driscoll, Colin L
2018-01-01
To examine practice variance of cochlear implant candidacy assessment and off-label indications across centers in the United States. Cross-sectional survey of the American Neurotology Society (ANS). A total of 81 surveys were returned from ANS members who report regular involvement in cochlear implant care. Overall there was a broad distribution in age and clinical experience, with most respondents reporting ACGME accreditation in neurotology and employment at an academic center. The annual volume of cochlear implant surgeries varied considerably across centers.Seventy-eight percent of respondents performed cochlear implantation for at least one of the following indications within the last 2 years: profound hearing loss in children less than 12 months of age (35, 43%), children with asymmetrical hearing loss where at least one ear was better than performance cutoff for age (25, 31%), adults with asymmetrical hearing where at least one ear was better than the performance cutoff for adult criteria (49, 61%), single-sided deafness (37, 46%), and ipsilateral vestibular schwannoma (28, 35%). Centers with a higher annual implant volume more frequently performed off-label implantation in all queried populations (all, p≤0.001), and performed surgery on infants with congenital deafness at a younger age (p = 0.013), compared with centers with lower surgical volume.When surveyed regarding speech perception testing practices for adult candidacy assessment, 75 (100%) respondents who answered this question reported routine use of AzBio sentences, 42 (56%) CNC word scores, and 26 (35%) HINT testing; only 7 (9%) reported using BKB-SIN testing and 6 (8%) reported using CUNY scores. Fifty-one (68%) reported routine use of speech-in-noise testing to determine adult cochlear implant candidacy, 21 (28%) reported selective use only when patient scores were borderline in quiet, and 3 (4%) reported that their center does not currently use testing in noise for candidacy determination. Nineteen (26%) solely used +10 dB signal-to-noise ratio (SNR), 12 (16%) solely used +5 dB SNR, and 41 (55%) used both +10 and +5 dB SNR. Overall, 19% (N = 14) only perform unilateral implantation in the Medicare population, while 81% (N = 58) consider bilateral implantation. Significant variation in cochlear implant candidacy assessment and off-label implantation exists across centers and providers in the United States resulting in healthcare inequities. The high percentage of surgeons performing implantations for off-label or nontraditional indications reflects the overly restrictive and dated status of current implant guidelines. With greater adoption of more difficult speech perception testing in noise, careful clinical judgment is needed to maintain a favorable risk-benefit balance for prospective implant candidates.
Kraaijenga, Véronique J C; Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Smit, Adriana L; Stokroos, Robert J; Hendrice, Nadia; Free, Rolien H; Maat, Bert; Frijns, Johan H M; Briaire, Jeroen J; Mylanus, E A M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko
2017-09-01
To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential BiCIs. A multicenter randomized clinical trial was conducted between January 12, 2010, and September 2, 2012, at 5 tertiary referral centers among 40 participants eligible for BiCIs. Main inclusion criteria were postlingual severe to profound hearing loss, age 18 to 70 years, and a maximum duration of 10 years without hearing aid use in both ears. Data analysis was conducted from May 24 to June 12, 2016. The simultaneous BiCI group received 2 cochlear implants during 1 surgical procedure. The sequential BiCI group received 2 cochlear implants with an interval of 2 years between implants. First, the results 1 year after receiving simultaneous BiCIs were compared with the results 1 year after receiving sequential BiCIs. Second, the results of 3 years of follow-up for both groups were compared separately. The primary outcome measure was speech intelligibility in noise from straight ahead. Secondary outcome measures were speech intelligibility in noise from spatially separated sources, speech intelligibility in silence, localization capabilities, and self-reported benefits assessed with various hearing and quality of life questionnaires. Nineteen participants were randomized to receive simultaneous BiCIs (11 women and 8 men; median age, 52 years [interquartile range, 36-63 years]), and another 19 participants were randomized to undergo sequential BiCIs (8 women and 11 men; median age, 54 years [interquartile range, 43-64 years]). Three patients did not receive a second cochlear implant and were unavailable for follow-up. Comparable results were found 1 year after simultaneous or sequential BiCIs for speech intelligibility in noise from straight ahead (difference, 0.9 dB [95% CI, -3.1 to 4.4 dB]) and all secondary outcome measures except for localization with a 30° angle between loudspeakers (difference, -10% [95% CI, -20.1% to 0.0%]). In the sequential BiCI group, all participants performed significantly better after the BiCIs on speech intelligibility in noise from spatially separated sources and on all localization tests, which was consistent with most of the participants' self-reported hearing capabilities. Speech intelligibility-in-noise results improved in the simultaneous BiCI group up to 3 years following the BiCIs. This study shows comparable objective and subjective hearing results 1 year after receiving simultaneous BiCIs and sequential BiCIs with an interval of 2 years between implants. It also shows a significant benefit of sequential BiCIs over a unilateral cochlear implant. Until 3 years after receiving simultaneous BiCIs, speech intelligibility in noise significantly improved compared with previous years. trialregister.nl Identifier: NTR1722.
Mahon, M; Vickers, D; McCarthy, K; Barker, R; Merritt, R; Szagun, G; Mann, W; Rajput, K
2011-05-01
A 5-year retrospective audit of demographic, audiological, and other records of 147 children implanted at one London centre was conducted. The aim was to detail the number of children implanted, with a specific focus on children from families with English as an additional language (EAL), and to compare these children with children from monolingual English-speaking families on a variety of characteristics known to affect paediatric cochlear implant outcomes. In all, 28% of children were from families where English is an additional language, with 15 different languages recorded. There were no differences between EAL and English-speaking children with respect to age of implantation; bilateral versus unilateral implants or hearing levels in better ear. There were differences between these groups in aetiology, in the occurrence of additional needs, and in educational placements. Information about speech and language outcomes was difficult to gather. Conclusions indicate the need for more detailed record-keeping especially about children's home languages for purposes of planning intervention and for the inclusion of children with EAL in future studies.
Finke, Mareike; Strauß-Schier, Angelika; Kludt, Eugen; Büchner, Andreas; Illg, Angelika
2017-05-01
Treatment with cochlear implants (CIs) in single-sided deaf individuals started less than a decade ago. CIs can successfully reduce incapacitating tinnitus on the deaf ear and allow, so some extent, the restoration of binaural hearing. Until now, systematic evaluations of subjective CI benefit in post-lingually single-sided deaf individuals and analyses of speech intelligibility outcome for the CI in isolation have been lacking. For the prospective part of this study, the Bern Benefit in Single-Sided Deafness Questionnaire (BBSS) was administered to 48 single-sided deaf CI users to evaluate the subjectively perceived CI benefit across different listening situations. In the retrospective part, speech intelligibility outcome with the CI up to 12 month post-activation was compared between 100 single-sided deaf CI users and 125 bilaterally implanted CI users (2nd implant). The positive median ratings in the BBSS differed significantly from zero for all items suggesting that most individuals with single-sided deafness rate their CI as beneficial across listening situations. The speech perception scores in quiet and noise improved significantly over time in both groups of CI users. Speech intelligibility with the CI in isolation was significantly better in bilaterally implanted CI users (2nd implant) compared to the scores obtained from single-sided deaf CI users. Our results indicate that CI users with single-sided deafness can reach open set speech understanding with their CI in isolation, encouraging the extension of the CI indication to individuals with normal hearing on the contralateral ear. Compared to the performance reached with bilateral CI users' second implant, speech reception threshold are lower, indicating an aural preference and dominance of the normal hearing ear. The results from the BBSS propose good satisfaction with the CI across several listening situations. Copyright © 2017 Elsevier B.V. All rights reserved.
Firszt, Jill B.; Reeder, Ruth M.; Holden, Laura K.
2016-01-01
Objectives At a minimum, unilateral hearing loss (UHL) impairs sound localization ability and understanding speech in noisy environments, particularly if the loss is severe to profound. Accompanying the numerous negative consequences of UHL is considerable unexplained individual variability in the magnitude of its effects. Identification of co-variables that affect outcome and contribute to variability in UHLs could augment counseling, treatment options, and rehabilitation. Cochlear implantation as a treatment for UHL is on the rise yet little is known about factors that could impact performance or whether there is a group at risk for poor cochlear implant outcomes when hearing is near-normal in one ear. The overall goal of our research is to investigate the range and source of variability in speech recognition in noise and localization among individuals with severe to profound UHL and thereby help determine factors relevant to decisions regarding cochlear implantation in this population. Design The present study evaluated adults with severe to profound UHL and adults with bilateral normal hearing. Measures included adaptive sentence understanding in diffuse restaurant noise, localization, roving-source speech recognition (words from 1 of 15 speakers in a 140° arc) and an adaptive speech-reception threshold psychoacoustic task with varied noise types and noise-source locations. There were three age-gender-matched groups: UHL (severe to profound hearing loss in one ear and normal hearing in the contralateral ear), normal hearing listening bilaterally, and normal hearing listening unilaterally. Results Although the normal-hearing-bilateral group scored significantly better and had less performance variability than UHLs on all measures, some UHL participants scored within the range of the normal-hearing-bilateral group on all measures. The normal-hearing participants listening unilaterally had better monosyllabic word understanding than UHLs for words presented on the blocked/deaf side but not the open/hearing side. In contrast, UHLs localized better than the normal hearing unilateral listeners for stimuli on the open/hearing side but not the blocked/deaf side. This suggests that UHLs had learned strategies for improved localization on the side of the intact ear. The UHL and unilateral normal hearing participant groups were not significantly different for speech-in-noise measures. UHL participants with childhood rather than recent hearing loss onset localized significantly better; however, these two groups did not differ for speech recognition in noise. Age at onset in UHL adults appears to affect localization ability differently than understanding speech in noise. Hearing thresholds were significantly correlated with speech recognition for UHL participants but not the other two groups. Conclusions Auditory abilities of UHLs varied widely and could be explained only in part by hearing threshold levels. Age at onset and length of hearing loss influenced performance on some, but not all measures. Results support the need for a revised and diverse set of clinical measures, including sound localization, understanding speech in varied environments and careful consideration of functional abilities as individuals with severe to profound UHL are being considered potential cochlear implant candidates. PMID:28067750
Children with bilateral cochlear implants identify emotion in speech and music.
Volkova, Anna; Trehub, Sandra E; Schellenberg, E Glenn; Papsin, Blake C; Gordon, Karen A
2013-03-01
This study examined the ability of prelingually deaf children with bilateral implants to identify emotion (i.e. happiness or sadness) in speech and music. Participants in Experiment 1 were 14 prelingually deaf children from 5-7 years of age who had bilateral implants and 18 normally hearing children from 4-6 years of age. They judged whether linguistically neutral utterances produced by a man and woman sounded happy or sad. Participants in Experiment 2 were 14 bilateral implant users from 4-6 years of age and the same normally hearing children as in Experiment 1. They judged whether synthesized piano excerpts sounded happy or sad. Child implant users' accuracy of identifying happiness and sadness in speech was well above chance levels but significantly below the accuracy achieved by children with normal hearing. Similarly, their accuracy of identifying happiness and sadness in music was well above chance levels but significantly below that of children with normal hearing, who performed at ceiling. For the 12 implant users who participated in both experiments, performance on the speech task correlated significantly with performance on the music task and implant experience was correlated with performance on both tasks. Child implant users' accurate identification of emotion in speech exceeded performance in previous studies, which may be attributable to fewer response alternatives and the use of child-directed speech. Moreover, child implant users' successful identification of emotion in music indicates that the relevant cues are accessible at a relatively young age.
2013-01-01
Children with severe hearing loss most likely receive the greatest benefit from a cochlear implant (CI) when implanted at less than 2 years of age. Children with a hearing loss may also benefit greater from binaural sensory stimulation. Four children who received their first CI under 12 months of age were included in this study. Effects on auditory development were determined using the German LittlEARS Auditory Questionnaire, closed- and open-set monosyllabic word tests, aided free-field, the Mainzer and Göttinger speech discrimination tests, Monosyllabic-Trochee-Polysyllabic (MTP), and Listening Progress Profile (LiP). Speech production and grammar development were evaluated using a German language speech development test (SETK), reception of grammar test (TROG-D) and active vocabulary test (AWST-R). The data showed that children implanted under 12 months of age reached open-set monosyllabic word discrimination at an age of 24 months. LiP results improved over time, and children recognized 100% of words in the MTP test after 12 months. All children performed as well as or better than their hearing peers in speech production and grammar development. SETK showed that the speech development of these children was in general age appropriate. The data suggests that early hearing loss intervention benefits speech and language development and supports the trend towards early cochlear implantation. Furthermore, the data emphasizes the potential benefits associated with bilateral implantation. PMID:23509653
May-Mederake, Birgit; Shehata-Dieler, Wafaa
2013-01-01
Children with severe hearing loss most likely receive the greatest benefit from a cochlear implant (CI) when implanted at less than 2 years of age. Children with a hearing loss may also benefit greater from binaural sensory stimulation. Four children who received their first CI under 12 months of age were included in this study. Effects on auditory development were determined using the German LittlEARS Auditory Questionnaire, closed- and open-set monosyllabic word tests, aided free-field, the Mainzer and Göttinger speech discrimination tests, Monosyllabic-Trochee-Polysyllabic (MTP), and Listening Progress Profile (LiP). Speech production and grammar development were evaluated using a German language speech development test (SETK), reception of grammar test (TROG-D) and active vocabulary test (AWST-R). The data showed that children implanted under 12 months of age reached open-set monosyllabic word discrimination at an age of 24 months. LiP results improved over time, and children recognized 100% of words in the MTP test after 12 months. All children performed as well as or better than their hearing peers in speech production and grammar development. SETK showed that the speech development of these children was in general age appropriate. The data suggests that early hearing loss intervention benefits speech and language development and supports the trend towards early cochlear implantation. Furthermore, the data emphasizes the potential benefits associated with bilateral implantation.
Binaural unmasking of multi-channel stimuli in bilateral cochlear implant users.
Van Deun, Lieselot; van Wieringen, Astrid; Francart, Tom; Büchner, Andreas; Lenarz, Thomas; Wouters, Jan
2011-10-01
Previous work suggests that bilateral cochlear implant users are sensitive to interaural cues if experimental speech processors are used to preserve accurate interaural information in the electrical stimulation pattern. Binaural unmasking occurs in adults and children when an interaural delay is applied to the envelope of a high-rate pulse train. Nevertheless, for speech perception, binaural unmasking benefits have not been demonstrated consistently, even with coordinated stimulation at both ears. The present study aimed at bridging the gap between basic psychophysical performance on binaural signal detection tasks on the one hand and binaural perception of speech in noise on the other hand. Therefore, binaural signal detection was expanded to multi-channel stimulation and biologically relevant interaural delays. A harmonic complex, consisting of three sinusoids (125, 250, and 375 Hz), was added to three 125-Hz-wide noise bands centered on the sinusoids. When an interaural delay of 700 μs was introduced, an average BMLD of 3 dB was established. Outcomes are promising in view of real-life benefits. Future research should investigate the generalization of the observed benefits for signal detection to speech perception in everyday listening situations and determine the importance of coordination of bilateral speech processors and accentuation of envelope cues.
Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants
Dietz, Mathias
2015-01-01
In patients with bilateral cochlear implants (CIs), pairing matched interaural electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, and spatial release from masking. Because clinical procedures typically do not include patient-specific interaural electrode pairing, it remains the case that each electrode is allocated to a generic frequency range, based simply on the electrode number. Two psychoacoustic techniques for determining interaurally paired electrodes have been demonstrated in several studies: interaural pitch comparison and interaural time difference (ITD) sensitivity. However, these two methods are rarely, if ever, compared directly. A third, more objective method is to assess the amplitude of the binaural interaction component (BIC) derived from electrically evoked auditory brainstem responses for different electrode pairings; a method has been demonstrated to be a potential candidate for bilateral CI users. Here, we tested all three measures in the same eight CI users. We found good correspondence between the electrode pair producing the largest BIC and the electrode pair producing the maximum ITD sensitivity. The correspondence between the pairs producing the largest BIC and the pitch-matched electrode pairs was considerably weaker, supporting the previously proposed hypothesis that whilst place pitch might adapt over time to accommodate mismatched inputs, sensitivity to ITDs does not adapt to the same degree. PMID:26631108
Lathuillière, Marine; Merklen, Fanny; Piron, Jean-Pierre; Sicard, Marielle; Villemus, Françoise; Menjot de Champfleur, Nicolas; Venail, Frédéric; Uziel, Alain; Mondain, Michel
2017-01-01
To assess the feasibility of using cone-beam computed tomography (CBCT) in young children with cochlear implants (CIs) and study the effect of intracochlear position on electrophysiological and behavioral measurements. A total of 40 children with either unilateral or bilateral cochlear implants were prospectively included in the study. Electrode placement and insertion angles were studied in 55 Cochlear ® implants (16 straight arrays and 39 perimodiolar arrays), using either CBCT or X-ray imaging. CBCT or X-ray imaging were scheduled when the children were leaving the recovery room. We recorded intraoperative and postoperative neural response telemetry threshold (T-NRT) values, intraoperative and postoperative electrode impedance values, as well as behavioral T (threshold) and C (comfort) levels on electrodes 1, 5, 10, 15 and 20. CBCT imaging was feasible without any sedation in 24 children (60%). Accidental scala vestibuli insertion was observed in 3 out of 24 implants as assessed by CBCT. The mean insertion angle was 339.7°±35.8°. The use of a perimodiolar array led to higher angles of insertion, lower postoperative T-NRT, as well as decreased behavioral T and C levels. We found no significant effect of either electrode array position or angle of insertion on electrophysiological data. CBCT appears to be a reliable tool for anatomical assessment of young children with CIs. Intracochlear position had no significant effect on the electrically evoked compound action potential (ECAP) threshold. Our CBCT protocol must be improved to increase the rate of successful investigations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Choi, Ji Eun; Moon, Il Joon; Kim, Eun Yeon; Park, Hee-Sung; Kim, Byung Kil; Chung, Won-Ho; Cho, Yang-Sun; Brown, Carolyn J; Hong, Sung Hwa
The aim of this study was to compare binaural performance of auditory localization task and speech perception in babble measure between children who use a cochlear implant (CI) in one ear and a hearing aid (HA) in the other (bimodal fitting) and those who use bilateral CIs. Thirteen children (mean age ± SD = 10 ± 2.9 years) with bilateral CIs and 19 children with bimodal fitting were recruited to participate. Sound localization was assessed using a 13-loudspeaker array in a quiet sound-treated booth. Speakers were placed in an arc from -90° azimuth to +90° azimuth (15° interval) in horizontal plane. To assess the accuracy of sound location identification, we calculated the absolute error in degrees between the target speaker and the response speaker during each trial. The mean absolute error was computed by dividing the sum of absolute errors by the total number of trials. We also calculated the hemifield identification score to reflect the accuracy of right/left discrimination. Speech-in-babble perception was also measured in the sound field using target speech presented from the front speaker. Eight-talker babble was presented in the following four different listening conditions: from the front speaker (0°), from one of the two side speakers (+90° or -90°), from both side speakers (±90°). Speech, spatial, and quality questionnaire was administered. When the two groups of children were directly compared with each other, there was no significant difference in localization accuracy ability or hemifield identification score under binaural condition. Performance in speech perception test was also similar to each other under most babble conditions. However, when the babble was from the first device side (CI side for children with bimodal stimulation or first CI side for children with bilateral CIs), speech understanding in babble by bilateral CI users was significantly better than that by bimodal listeners. Speech, spatial, and quality scores were comparable with each other between the two groups. Overall, the binaural performance was similar to each other between children who are fit with two CIs (CI + CI) and those who use bimodal stimulation (HA + CI) in most conditions. However, the bilateral CI group showed better speech perception than the bimodal CI group when babble was from the first device side (first CI side for bilateral CI users or CI side for bimodal listeners). Therefore, if bimodal performance is significantly below the mean bilateral CI performance on speech perception in babble, these results suggest that a child should be considered to transit from bimodal stimulation to bilateral CIs.
Acoustic Analysis of Speech of Cochlear Implantees and Its Implications
Patadia, Rajesh; Govale, Prajakta; Rangasayee, R.; Kirtane, Milind
2012-01-01
Objectives Cochlear implantees have improved speech production skills compared with those using hearing aids, as reflected in their acoustic measures. When compared to normal hearing controls, implanted children had fronted vowel space and their /s/ and /∫/ noise frequencies overlapped. Acoustic analysis of speech provides an objective index of perceived differences in speech production which can be precursory in planning therapy. The objective of this study was to compare acoustic characteristics of speech in cochlear implantees with those of normal hearing age matched peers to understand implications. Methods Group 1 consisted of 15 children with prelingual bilateral severe-profound hearing loss (age, 5-11 years; implanted between 4-10 years). Prior to an implant behind the ear, hearing aids were used; prior & post implantation subjects received at least 1 year of aural intervention. Group 2 consisted of 15 normal hearing age matched peers. Sustained productions of vowels and words with selected consonants were recorded. Using Praat software for acoustic analysis, digitized speech tokens were measured for F1, F2, and F3 of vowels; centre frequency (Hz) and energy concentration (dB) in burst; voice onset time (VOT in ms) for stops; centre frequency (Hz) of noise in /s/; rise time (ms) for affricates. A t-test was used to find significant differences between groups. Results Significant differences were found in VOT for /b/, F1 and F2 of /e/, and F3 of /u/. No significant differences were found for centre frequency of burst, energy concentration for stops, centre frequency of noise in /s/, or rise time for affricates. These findings suggest that auditory feedback provided by cochlear implants enable subjects to monitor production of speech sounds. Conclusion Acoustic analysis of speech is an essential method for discerning characteristics which have or have not been improved by cochlear implantation and thus for planning intervention. PMID:22701768
Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya
2014-04-01
To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.
Canale, Andrea; Dalmasso, Giulia; Dagna, Federico; Lacilla, Michelangelo; Montuschi, Carla; Rosa, Rosalba Di; Albera, Roberto
2016-08-01
To determine whether speech recognition scores (SRS) differ between adults with long-term auditory deprivation in the implanted ear and adults who received cochlear implant (CI) in the nonsound-deprived ear, either for hearing aid-assisted or due to rapidly deteriorating hearing loss. Retrospective study. Speech recognition scores at evaluations (3 and 14 months postimplantation) conducted with CI alone at 60-dB sound pressure level intensity were compared in 15 patients (4 with bilateral severe hearing loss; 11 with asymmetric hearing loss, 7 of which had contralateral hearing aid), all with long-term auditory deprivation (mean duration 16.9 years) (group A), and in 15 other patients with postlingual hearing loss (10 symmetric, 5 asymmetric with bimodal stimulation) (controls, group B). Comparison of mean percentage of correctly recognized words on speech audiometry at 3 and 14 months showed improvement within each group (P < 0.05). Between-group comparison showed no significant difference at 3 (P = 0.17) or 14 months (P = 0.46). Comparison of SRSs in group A (bimodal stimulation [n = 7] and binaural sound deprivation [n = 4]) versus group B showed no significant differences at 3 (bimodal stimulation P = 0.16; binaural sound deprivation P = 0.19) or 14 months (bimodal stimulation P = 0.14; binaural sound deprivation P = 0.82). Speech recognition scores in monaural and binaural sound-deprived ears did not significantly differ from ears with unilateral cochlear implantation in nonsound-deprived ears when tested with CI alone. Improvement in the implanted worse ear indicates that it could be a potential candidate ear for cochlear implantation even when sound deprived. 4. Laryngoscope, 126:1905-1910, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Lin, Jean-Pierre; Kaminska, Margaret; Perides, Sarah; Gimeno, Hortensia; Baker, Lesley; Lumsden, Daniel E; Britz, Anzell; Driver, Sandra; Fitzgerald-O'Connor, Alec; Selway, Richard
2017-01-01
Early onset dystonia (dyskinesia) and deafness in childhood pose significant challenges for children and carers and are the cause of multiple disability. It is particularly tragic when the child cannot make use of early cochlear implantation (CI) technology to relieve deafness and improve language and communication, because severe cervical and truncal dystonia brushes off the magnetic amplifier behind the ears. Bilateral globus pallidus internus (GPi) deep brain stimulation (DBS) neuromodulation can reduce dyskinesia, thus supporting CI neuromodulation success. We describe the importance of the order of dual neuromodulation surgery for dystonia and deafness. First with bilateral GPi DBS using a rechargeable ACTIVA-RC neurostimulator followed 5 months later by unilateral CI with a Harmony (BTE) Advanced Bionics Hi Res 90 K cochlear device. This double neuromodulation was performed in series in a 12.5 kg 5 year-old ex-24 week gestation-born twin without a cerebellum. Relief of dyskinesia enabled continuous use of the CI amplifier. Language understanding and communication improved. Dystonic storms abated. Tolerance of sitting increased with emergence of manual function. Status dystonicus ensued 10 days after ACTIVA-RC removal for infection-erosion at 3 years and 10 months. He required intensive care and DBS re-implantation 3 weeks later together with 8 months of hospital care. Today he is virtually back to the level of functioning before the DBS removal in 2012 and background medication continues to be slowly weaned. This case illustrates that early neuromodulation with DBS for dystonic cerebral palsy followed by CI for deafness is beneficial. Both should be considered early i.e. under the age of five years. The DBS should precede the CI to maximise dystonia reduction and thus benefits from CI. This requires close working between the paediatric DBS and CI services. Copyright © 2016. Published by Elsevier Ltd.
Nicholas, Johanna; Tobey, Emily; Davidson, Lisa
2016-01-01
Purpose The purpose of the present investigation is to differentiate children using cochlear implants (CIs) who did or did not achieve age-appropriate language scores by midelementary grades and to identify risk factors for persistent language delay following early cochlear implantation. Materials and Method Children receiving unilateral CIs at young ages (12–38 months) were tested longitudinally and classified with normal language emergence (n = 19), late language emergence (n = 22), or persistent language delay (n = 19) on the basis of their test scores at 4.5 and 10.5 years of age. Relative effects of demographic, audiological, linguistic, and academic characteristics on language emergence were determined. Results Age at CI was associated with normal language emergence but did not differentiate late emergence from persistent delay. Children with persistent delay were more likely to use left-ear implants and older speech processor technology. They experienced higher aided thresholds and lower speech perception scores. Persistent delay was foreshadowed by low morphosyntactic and phonological diversity in preschool. Logistic regression analysis predicted normal language emergence with 84% accuracy and persistent language delay with 74% accuracy. Conclusion CI characteristics had a strong effect on persistent versus resolving language delay, suggesting that right-ear (or bilateral) devices, technology upgrades, and improved audibility may positively influence long-term language outcomes. PMID:26501740
Attias, Joseph; Greenstein, Tally; Peled, Miriam; Ulanovski, David; Wohlgelernter, Jay; Raveh, Eyal
The aim of the study was to compare auditory and speech outcomes and electrical parameters on average 8 years after cochlear implantation between children with isolated auditory neuropathy (AN) and children with sensorineural hearing loss (SNHL). The study was conducted at a tertiary, university-affiliated pediatric medical center. The cohort included 16 patients with isolated AN with current age of 5 to 12.2 years who had been using a cochlear implant for at least 3.4 years and 16 control patients with SNHL matched for duration of deafness, age at implantation, type of implant, and unilateral/bilateral implant placement. All participants had had extensive auditory rehabilitation before and after implantation, including the use of conventional hearing aids. Most patients received Cochlear Nucleus devices, and the remainder either Med-El or Advanced Bionics devices. Unaided pure-tone audiograms were evaluated before and after implantation. Implantation outcomes were assessed by auditory and speech recognition tests in quiet and in noise. Data were also collected on the educational setting at 1 year after implantation and at school age. The electrical stimulation measures were evaluated only in the Cochlear Nucleus implant recipients in the two groups. Similar mapping and electrical measurement techniques were used in the two groups. Electrical thresholds, comfortable level, dynamic range, and objective neural response telemetry threshold were measured across the 22-electrode array in each patient. Main outcome measures were between-group differences in the following parameters: (1) Auditory and speech tests. (2) Residual hearing. (3) Electrical stimulation parameters. (4) Correlations of residual hearing at low frequencies with electrical thresholds at the basal, middle, and apical electrodes. The children with isolated AN performed equally well to the children with SNHL on auditory and speech recognition tests in both quiet and noise. More children in the AN group than the SNHL group were attending mainstream educational settings at school age, but the difference was not statistically significant. Significant between-group differences were noted in electrical measurements: the AN group was characterized by a lower current charge to reach subjective electrical thresholds, lower comfortable level and dynamic range, and lower telemetric neural response threshold. Based on pure-tone audiograms, the children with AN also had more residual hearing before and after implantation. Highly positive coefficients were found on correlation analysis between T levels across the basal and midcochlear electrodes and low-frequency acoustic thresholds. Prelingual children with isolated AN who fail to show expected oral and auditory progress after extensive rehabilitation with conventional hearing aids should be considered for cochlear implantation. Children with isolated AN had similar pattern as children with SNHL on auditory performance tests after cochlear implantation. The lower current charge required to evoke subjective and objective electrical thresholds in children with AN compared with children with SNHL may be attributed to the contribution to electrophonic hearing from the remaining neurons and hair cells. In addition, it is also possible that mechanical stimulation of the basilar membrane, as in acoustic stimulation, is added to the electrical stimulation of the cochlear implant.
Derks, Laura S M; Wegner, Inge; Smit, Adriana L; Thomeer, Hans G X M; Topsakal, Vedat; Grolman, Wilko
2016-01-01
Introduction Cochlear implantation is an increasingly common procedure in the treatment of severe to profound sensorineural hearing loss (SNHL) in children and adults. It is often performed as a day-case procedure. The major drive towards day-case surgery has been from a logistical, economical and societal perspective, but we also speculate that the patient's quality of life (QoL) is at least equal to inpatient surgery if not increased as a result of rapid discharge and rehabilitation. Even though cochlear implantation seems well suited to a day-case approach and this even seems to be common practice in some countries, evidence is scarce and of low quality to guide us towards the preferred treatment option. Methods and analysis A single-centre, non-blinded, randomised, controlled trial was designed to (primarily) investigate the effect on general QoL of day-case cochlear implantation compared to inpatient cochlear implantation and (secondarily) the effect of both methods on (subjective) hearing improvement, disease-specific QoL, tinnitus, vertigo and cost-effectiveness. 30 adult patients with severe to profound bilateral postlingual SNHL who are eligible for unilateral cochlear implantation will be randomly assigned to either the day-case or inpatient treatment group. The outcome measures will be assessed using auditory evaluations, questionnaires (preoperatively, at 1-week, 3-week, 3-month and 1-year follow-up) and costs diaries (weekly during the first month postoperatively, after which once in a month until 1-year follow-up). Preoperative and postoperative outcomes will be compared. The difference in costs and benefit will be represented using the incremental cost utility/effectiveness ratio. The analyses will be carried out on an intention-to-treat basis. Ethics and dissemination This research protocol was approved by the Institutional Review Board of the UMC Utrecht (NL45590.041.13; V.5, November 2015). The trial results will be disseminated through peer-reviewed medical journals and presented at scientific conferences. Trial registration number NTR4464; Pre-results. PMID:27697874
Binaural hearing in children using Gaussian enveloped and transposed tones.
Ehlers, Erica; Kan, Alan; Winn, Matthew B; Stoelb, Corey; Litovsky, Ruth Y
2016-04-01
Children who use bilateral cochlear implants (BiCIs) show significantly poorer sound localization skills than their normal hearing (NH) peers. This difference has been attributed, in part, to the fact that cochlear implants (CIs) do not faithfully transmit interaural time differences (ITDs) and interaural level differences (ILDs), which are known to be important cues for sound localization. Interestingly, little is known about binaural sensitivity in NH children, in particular, with stimuli that constrain acoustic cues in a manner representative of CI processing. In order to better understand and evaluate binaural hearing in children with BiCIs, the authors first undertook a study on binaural sensitivity in NH children ages 8-10, and in adults. Experiments evaluated sound discrimination and lateralization using ITD and ILD cues, for stimuli with robust envelope cues, but poor representation of temporal fine structure. Stimuli were spondaic words, Gaussian-enveloped tone pulse trains (100 pulse-per-second), and transposed tones. Results showed that discrimination thresholds in children were adult-like (15-389 μs for ITDs and 0.5-6.0 dB for ILDs). However, lateralization based on the same binaural cues showed higher variability than seen in adults. Results are discussed in the context of factors that may be responsible for poor representation of binaural cues in bilaterally implanted children.
Wang, Jenny R; Yuen, Heng W; Shipp, David B; Stewart, Suzanne; Lin, Vincent Y W; Chen, Joseph M; Nedzelski, Julian M
2010-12-01
Evaluate the characteristics and outcomes of patients with autoimmune inner ear disease (AIED) who have undergone cochlear implantation (CI) and compare post-CI performance in AIED to matched controls. Retrospective case control study. Study cohort was comprised of 25 adult implantees (AIED [n = 18], Cogan syndrome [n = 7]). The AIED group was defined by rapidly progressive bilateral sensorineural hearing loss leading to unusable hearing within weeks to months. Patients with Cogan syndrome, the archetypal inner ear autoimmune disease, were also examined and used for within-cohort comparison. Clinical and operative records were reviewed. Post-CI performance was assessed using open-set sentence tests. Age- and sex-matched individuals deafened by other postlingual causes were used as controls. Of 25 patients, 24 had uneventful, full electrode insertions. One AIED patient had partial insertion due to cochlear ossification and did not achieve open-set speech perception post-CI. Mean open-set sentence scores for study patients with uneventful insertions were 92.8%, 97.3%, and 96.4% at 6 months, 1 year, and ≥ 2 years, respectively. Compared to matched controls, patients deafened by autoimmune causes had significantly higher post-CI performance at all postoperative test intervals (P < .05). There was no significant difference in postimplantation performance between Cogan syndrome and AIED patients. To our knowledge this was the largest study of cochlear implantation in AIED and Cogan syndrome patients. In our experience, both groups generally attained high levels of post-CI speech perception and performed above average. Cochlear ossification affecting implantation in Cogan syndrome patients was not observed in our series, contrary to some reports.
van Hoesel, Richard J M
2015-04-01
One of the key benefits of using cochlear implants (CIs) in both ears rather than just one is improved localization. It is likely that in complex listening scenes, improved localization allows bilateral CI users to orient toward talkers to improve signal-to-noise ratios and gain access to visual cues, but to date, that conjecture has not been tested. To obtain an objective measure of that benefit, seven bilateral CI users were assessed for both auditory-only and audio-visual speech intelligibility in noise using a novel dynamic spatial audio-visual test paradigm. For each trial conducted in spatially distributed noise, first, an auditory-only cueing phrase that was spoken by one of four talkers was selected and presented from one of four locations. Shortly afterward, a target sentence was presented that was either audio-visual or, in another test configuration, audio-only and was spoken by the same talker and from the same location as the cueing phrase. During the target presentation, visual distractors were added at other spatial locations. Results showed that in terms of speech reception thresholds (SRTs), the average improvement for bilateral listening over the better performing ear alone was 9 dB for the audio-visual mode, and 3 dB for audition-alone. Comparison of bilateral performance for audio-visual and audition-alone showed that inclusion of visual cues led to an average SRT improvement of 5 dB. For unilateral device use, no such benefit arose, presumably due to the greatly reduced ability to localize the target talker to acquire visual information. The bilateral CI speech intelligibility advantage over the better ear in the present study is much larger than that previously reported for static talker locations and indicates greater everyday speech benefits and improved cost-benefit than estimated to date.
Lopez-Poveda, Enrique A; Eustaquio-Martín, Almudena; Stohl, Joshua S; Wolford, Robert D; Schatzer, Reinhold; Gorospe, José M; Ruiz, Santiago Santa Cruz; Benito, Fernando; Wilson, Blake S
2017-05-01
We have recently proposed a binaural cochlear implant (CI) sound processing strategy inspired by the contralateral medial olivocochlear reflex (the MOC strategy) and shown that it improves intelligibility in steady-state noise (Lopez-Poveda et al., 2016, Ear Hear 37:e138-e148). The aim here was to evaluate possible speech-reception benefits of the MOC strategy for speech maskers, a more natural type of interferer. Speech reception thresholds (SRTs) were measured in six bilateral and two single-sided deaf CI users with the MOC strategy and with a standard (STD) strategy. SRTs were measured in unilateral and bilateral listening conditions, and for target and masker stimuli located at azimuthal angles of (0°, 0°), (-15°, +15°), and (-90°, +90°). Mean SRTs were 2-5 dB better with the MOC than with the STD strategy for spatially separated target and masker sources. For bilateral CI users, the MOC strategy (1) facilitated the intelligibility of speech in competition with spatially separated speech maskers in both unilateral and bilateral listening conditions; and (2) led to an overall improvement in spatial release from masking in the two listening conditions. Insofar as speech is a more natural type of interferer than steady-state noise, the present results suggest that the MOC strategy holds potential for promising outcomes for CI users. Copyright © 2017. Published by Elsevier B.V.
ERIC Educational Resources Information Center
Clark, Catherine; Scott, Larry
This brochure explains what a cochlear implant is, lists the types of individuals with deafness who may be helped by a cochlear implant, describes the process of evaluating people for cochlear implants, discusses the surgical process for implanting the aid, traces the path of sound through the cochlear implant to the brain, notes the costs of…
Wolfe, Jace; Schafer, Erin; Parkinson, Aaron; John, Andrew; Hudson, Mary; Wheeler, Julie; Mucci, Angie
2013-01-01
The objective of this study was to compare speech recognition in quiet and in noise for cochlear implant recipients using two different types of personal frequency modulation (FM) systems (directly coupled [direct auditory input] versus induction neckloop) with each of two sound processors (Cochlear Nucleus Freedom versus Cochlear Nucleus 5). Two different experiments were conducted within this study. In both these experiments, mixing of the FM signal within the Freedom processor was implemented via the same scheme used clinically for the Freedom sound processor. In Experiment 1, the aforementioned comparisons were conducted with the Nucleus 5 programmed so that the microphone and FM signals were mixed and then the mixed signals were subjected to autosensitivity control (ASC). In Experiment 2, comparisons between the two FM systems and processors were conducted again with the Nucleus 5 programmed to provide a more complex multistage implementation of ASC during the preprocessing stage. This study was a within-subject, repeated-measures design. Subjects were recruited from the patient population at the Hearts for Hearing Foundation in Oklahoma City, OK. Fifteen subjects participated in Experiment 1, and 16 subjects participated in Experiment 2. Subjects were adults who had used either unilateral or bilateral cochlear implants for at least 1 year. In this experiment, no differences were found in speech recognition in quiet obtained with the two different FM systems or the various sound-processor conditions. With each sound processor, speech recognition in noise was better with the directly coupled direct auditory input system relative to the neckloop system. The multistage ASC processing of the Nucleus 5 sound processor provided better performance than the single-stage approach for the Nucleus 5 and the Nucleus Freedom sound processor. Speech recognition in noise is substantially affected by the type of sound processor, FM system, and implementation of ASC used by a Cochlear implant recipient.
Surgical timing for bilateral simultaneous cochlear implants: When is best?
Franchella, Sebastiano; Bovo, Roberto; Bandolin, Luigia; Gheller, Flavia; Montino, Silvia; Borsetto, Daniele; Ghiselli, Sara; Martini, Alessandro
2018-06-01
Hearing loss is considered the most common congenital disease and the prevalence of neonatal deafness can be estimated between 1 and 2 cases per 1000 live births. Infant deafness must be diagnosed as early as possible and an effective therapeutic intervention needs to be carried out in order to avoid the serious consequences of hearing deprivation during the evolutionary period: alterations in the development of central auditory pathways and lack of language acquisition. The cochlear implant (CI) has proved to be the best instrument to solve the problem of auditory deprivation. In particular, the bilateral CI gives the patient access to binaural hearing which results in benefits in terms of sound localisation and discrimination. The optimal age of application of the CI is a widely discussed topic in the scientific community and the current guidelines indicate a period between 12 and 24 months of age, even though the supporters of the application before 12 months of age are nowadays increasing. The study is observational, retrospective, monocentric. 49 paediatric patients (<18 years) with simultaneous bilateral CIs were included. The audiometric threshold and speech tests were carried out during the follow-up 3, 6 and 12 months after the CIs activation and when the patient reached 2 years of age. The statistical analysis showed that undergoing bilateral implantation surgery before 2 years of age allows a satisfactory audiometric performance, while there are no particular benefits in performing the surgery before 1 year of age. As far as the speech outcome is concerned, the statistical analysis didn't show significant correlation between the earlier age of implantation and better speech performance if the operation is carried out before 2.5 years of age. The results of the study indicate that the optimal age to perform the simultaneous bilateral CIs surgery is between 12 and 24 months, without demonstrating any particular benefit in carrying out the procedure before 1 year of age. This may be clinically relevant in terms of avoiding the risks of diagnostic mistakes and reducing the related surgical risk in children under 1 year of age. Copyright © 2018. Published by Elsevier B.V.
Direct recordings from the auditory cortex in a cochlear implant user.
Nourski, Kirill V; Etler, Christine P; Brugge, John F; Oya, Hiroyuki; Kawasaki, Hiroto; Reale, Richard A; Abbas, Paul J; Brown, Carolyn J; Howard, Matthew A
2013-06-01
Electrical stimulation of the auditory nerve with a cochlear implant (CI) is the method of choice for treatment of severe-to-profound hearing loss. Understanding how the human auditory cortex responds to CI stimulation is important for advances in stimulation paradigms and rehabilitation strategies. In this study, auditory cortical responses to CI stimulation were recorded intracranially in a neurosurgical patient to examine directly the functional organization of the auditory cortex and compare the findings with those obtained in normal-hearing subjects. The subject was a bilateral CI user with a 20-year history of deafness and refractory epilepsy. As part of the epilepsy treatment, a subdural grid electrode was implanted over the left temporal lobe. Pure tones, click trains, sinusoidal amplitude-modulated noise, and speech were presented via the auxiliary input of the right CI speech processor. Additional experiments were conducted with bilateral CI stimulation. Auditory event-related changes in cortical activity, characterized by the averaged evoked potential and event-related band power, were localized to posterolateral superior temporal gyrus. Responses were stable across recording sessions and were abolished under general anesthesia. Response latency decreased and magnitude increased with increasing stimulus level. More apical intracochlear stimulation yielded the largest responses. Cortical evoked potentials were phase-locked to the temporal modulations of periodic stimuli and speech utterances. Bilateral electrical stimulation resulted in minimal artifact contamination. This study demonstrates the feasibility of intracranial electrophysiological recordings of responses to CI stimulation in a human subject, shows that cortical response properties may be similar to those obtained in normal-hearing individuals, and provides a basis for future comparisons with extracranial recordings.
Binaural sensitivity in children who use bilateral cochlear implants.
Ehlers, Erica; Goupell, Matthew J; Zheng, Yi; Godar, Shelly P; Litovsky, Ruth Y
2017-06-01
Children who are deaf and receive bilateral cochlear implants (BiCIs) perform better on spatial hearing tasks using bilateral rather than unilateral inputs; however, they underperform relative to normal-hearing (NH) peers. This gap in performance is multi-factorial, including the inability of speech processors to reliably deliver binaural cues. Although much is known regarding binaural sensitivity of adults with BiCIs, less is known about how the development of binaural sensitivity in children with BiCIs compared to NH children. Sixteen children (ages 9-17 years) were tested using synchronized research processors. Interaural time differences and interaural level differences (ITDs and ILDs, respectively) were presented to pairs of pitch-matched electrodes. Stimuli were 300-ms, 100-pulses-per-second, constant-amplitude pulse trains. In the first and second experiments, discrimination of interaural cues (either ITDs or ILDs) was measured using a two-interval left/right task. In the third experiment, subjects reported the perceived intracranial position of ITDs and ILDs in a lateralization task. All children demonstrated sensitivity to ILDs, possibly due to monaural level cues. Children who were born deaf had weak or absent sensitivity to ITDs; in contrast, ITD sensitivity was noted in children with previous exposure to acoustic hearing. Therefore, factors such as auditory deprivation, in particular, lack of early exposure to consistent timing differences between the ears, may delay the maturation of binaural circuits and cause insensitivity to binaural differences.
What Does Music Sound Like for a Cochlear Implant User?
Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J
2017-09-01
Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.
Goykhburg, M V; Bakhshinyan, V V; Petrova, I P; Wazybok, A; Kollmeier, B; Tavartkiladze, G A
The deterioration of speech intelligibility in the patients using cochlear implantation (CI) systems is especially well apparent in the noisy environment. It explains why phrasal speech tests, such as a Matrix sentence test, have become increasingly more popular in the speech audiometry during rehabilitation after CI. The Matrix test allows to estimate speech perception by the patients in a real life situation. The objective of this study was to assess the effectiveness of audiological rehabilitation of CI patients using the Russian-language version of the matrix test (RUMatrix) in free field in the noisy environment. 33 patients aged from 5 to 40 years with a more than 3 year experience of using cochlear implants inserted at the National Research Center for Audiology and Hearing Rehabilitation were included in our study. Five of these patients were implanted bilaterally. The results of our study showed a statistically significant improvement of speech intelligibility in the noisy environment after the speech processor adjustment; dynamics of the signal-to-noise ratio changes was -1.7 dB (p<0.001). The RUMatrix test is a highly efficient method for the estimation of speech intelligibility in the patients undergoing clinical investigations in the noisy environment. The high degree of comparability of the RUMatrix test with the Matrix tests in other languages makes possible its application in international multicenter studies.
Fitzgerald, Matthew B.; Prosolovich, Ksenia; Tan, Chin-Tuan; Glassman, E. Katelyn; Svirsky, Mario A.
2017-01-01
Background Many recipients of bilateral cochlear implants (CIs) may have differences in electrode insertion depth. Previous reports indicate that when a bilateral mismatch is imposed, performance on tests of speech understanding or sound localization becomes worse. If recipients of bilateral CIs cannot adjust to a difference in insertion depth, adjustments to the frequency table may be necessary to maximize bilateral performance. Purpose The purpose of this study was to examine the feasibility of using real-time manipulations of the frequency table to offset any decrements in performance resulting from a bilateral mismatch. Research Design A simulation of a CI was used because it allows for explicit control of the size of a bilateral mismatch. Such control is not available with users of CIs. Study Sample A total of 31 normal-hearing young adults participated in this study. Data Collection and Analysis Using a CI simulation, four bilateral mismatch conditions (0, 0.75, 1.5, and 3 mm) were created. In the left ear, the analysis filters and noise bands of the CI simulation were the same. In the right ear, the noise bands were shifted higher in frequency to simulate a bilateral mismatch. Then, listeners selected a frequency table in the right ear that was perceived as maximizing bilateral speech intelligibility. Word-recognition scores were then assessed for each bilateral mismatch condition. Listeners were tested with both a standard frequency table, which preserved a bilateral mismatch, or with their self-selected frequency table. Results Consistent with previous reports, bilateral mismatches of 1.5 and 3 mm yielded decrements in word recognition when the standard table was used in both ears. However, when listeners used the self-selected frequency table, performance was the same regardless of the size of the bilateral mismatch. Conclusions Self-selection of a frequency table appears to be a feasible method for ameliorating the negative effects of a bilateral mismatch. These data may have implications for recipients of bilateral CIs who cannot adapt to a bilateral mismatch, because they suggest that (1) such individuals may benefit from modification of the frequency table in one ear and (2) self-selection of a “most intelligible” frequency table may be a useful tool for determining how the frequency table should be altered to optimize speech recognition. PMID:28534729
Cochlear implants: a remarkable past and a brilliant future
Wilson, Blake S.; Dorman, Michael F.
2013-01-01
The aims of this paper are to (i) provide a brief history of cochlear implants; (ii) present a status report on the current state of implant engineering and the levels of speech understanding enabled by that engineering; (iii) describe limitations of current signal processing strategies and (iv) suggest new directions for research. With current technology the “average” implant patient, when listening to predictable conversations in quiet, is able to communicate with relative ease. However, in an environment typical of a workplace the average patient has a great deal of difficulty. Patients who are “above average” in terms of speech understanding, can achieve 100% correct scores on the most difficult tests of speech understanding in quiet but also have significant difficulty when signals are presented in noise. The major factors in these outcomes appear to be (i) a loss of low-frequency, fine structure information possibly due to the envelope extraction algorithms common to cochlear implant signal processing; (ii) a limitation in the number of effective channels of stimulation due to overlap in electric fields from electrodes, and (iii) central processing deficits, especially for patients with poor speech understanding. Two recent developments, bilateral implants and combined electric and acoustic stimulation, have promise to remediate some of the difficulties experienced by patients in noise and to reinstate low-frequency fine structure information. If other possibilities are realized, e.g., electrodes that emit drugs to inhibit cell death following trauma and to induce the growth of neurites toward electrodes, then the future is very bright indeed. PMID:18616994
Hsiao, Feilin; Gfeller, Kate
2013-01-01
This review of literature presents a systematic analysis of the capabilities and limitations of cochlear implant recipients regarding music perception. Specifically, it a) analyzes individual components of music (e.g., rhythm, timbre, and pitch) as they interface with the technical characteristics of cochlear implants and the perceptual abilities of cochlear implant recipients; and b) describes accommodations for music instruction that support successful participation of children with cochlear implants. This article consolidates research studies from various disciplines (audiology, hearing science, speech-language pathology, cochlear implants, and music therapy) to provide practical recommendations for educators in fostering the musical growth of children with cochlear implants. PMID:23469365
Evaluation of high-resolution MRI for preoperative screening for cochlear implantation
NASA Astrophysics Data System (ADS)
Madzivire, Mambidzeni; Camp, Jon J.; Lane, John; Witte, Robert J.; Robb, Richard A.
2002-05-01
The success of a cochlear implant is dependent on a functioning auditory nerve. An accurate noninvasive method for screening cochlear implant patients to help determine viability of the auditory nerve would allow physicians to better predict the success of the operation. In this study we measured the size of the auditory nerve relative to the size of the juxtaposed facial nerve and correlated these measurements with audiologic test results. The study involved 15 patients, and three normal volunteers. Noninvasive high-resolution bilateral MRI images were acquired from both 1.5T and 3T scanners. The images were reformatted to obtain an anatomically referenced oblique plane perpendicular to the auditory nerve. The cross- sectional areas of the auditory and facial nerves were determined in this plane. Assessment of the data is encouraging. The ratios of auditory to facial nerve size in the control subjects are close to the expected value of 1.0. Patient data ratios range from 0.73 to 1.3, with numbers significantly less than 1.0 suggesting auditory nerve atrophy. The acoustic nerve area correlated to audiologic test findings, particularly (R2equals0.68) to the count of words understood from a list of 100 words. These preliminary analyses suggest that a threshold of size may be determined to differentiate functional from nonfunctional auditory nerves.
Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.
Hassanzadeh, S
2012-10-01
This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.
Parental expectations and outcomes of pediatric cochlear implantation.
Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D
2009-10-01
Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.
Vlastarakos, Petros V; Vasileiou, Alexandra; Nikolopoulos, Thomas P
2017-12-01
We conducted an analysis to assess the relative contribution of auditory brainstem response (ABR) testing and auditory steady-state response (ASSR) testing in providing appropriate hearing aid fitting in hearing-impaired children with difficult or unreliable behavioral audiometry. Of 150 infants and children who had been referred to us for hearing assessment as part of a neonatal hearing screening and cochlear implantation program, we identified 5 who exhibited significant discrepancies between click-ABR and ASSR testing results and difficult or unreliable behavioral audiometry. Hearing aid fitting in pediatric cochlear implant candidates for a trial period of 3 to 6 months is a common practice in many implant programs, but monitoring the progress of the amplified infants and providing appropriate hearing aid fitting can be challenging. If we accept the premise that we can assess the linguistic progress of amplified infants with an acceptable degree of certainty, the auditory behavior that we are monitoring presupposes appropriate bilateral hearing aid fitting. This may become very challenging in young children, or even in older children with difficult or unreliable behavioral audiometry results. This challenge can be addressed by using data from both ABR and ASSR testing. Fitting attempts that employ data from only ABR testing provide amplification that involves the range of spoken language but is not frequency-specific. Hearing aid fitting should also incorporate and take into account ASSR data because reliance on ABR testing alone might compromise the validity of the monitoring process. In conclusion, we believe that ASSR threshold-based bilateral hearing aid fitting is necessary to provide frequency-specific amplification of hearing and appropriate propulsion in the prelinguistic vocalizations of monitored infants.
DI NARDO, W.; GIANNANTONIO, S.; DI GIUDA, D.; DE CORSO, E.; SCHINAIA, L.; PALUDETTI, G.
2013-01-01
SUMMARY Pre-surgery evaluation, indications for cochlear implantation and expectations in terms of post-operative functional results remain challenging topics in pre-lingually deaf adults. Our study has the purpose of determining the benefits of Single Photon Emission Tomography (SPECT) assessment in pre-surgical evaluation of pre-lingually deaf adults who are candidates for cochlear implantation. In 7 pre-lingually profoundly deaf patients, brain SPECT was performed at baseline conditions and in bilateral simultaneous multi-frequency acoustic stimulation. Six sagittal tomograms of both temporal cortices were used for semi-quantitative analysis in each patient. Percentage increases in cortical perfusion resulting from auditory stimulation were calculated. The results showed an inter-hemispherical asymmetry of the activation extension and intensity in the stimulated temporal areas. Consistent with the obtained brain activation data, patients were implanted preferring the side that showed higher activation after acoustic stimulus. Considering the increment in auditory perception performances, it was possible to point out a relationship between cortical brain activity shown by SPECT and hearing performances, and, even more significant, a correlation between post-operative functional performances and the activation of the most medial part of the sagittal temporal tomograms, corresponding to medium-high frequencies. In light of these findings, we believe that brain SPECT could be considered in the evaluation of deaf patients candidate for cochlear implantation, and that it plays a major role in functional assessment of the auditory cortex of pre-lingually deaf subjects, even if further studies are necessary to conclusively establish its utility. Further developments of this technique are possible by using trans-tympanic electrical stimulation of the cochlear promontory, which could give the opportunity to study completely deaf patients, whose evaluation is objectively difficult with current audiological methods. PMID:23620636
Cochlear implants in children implanted in Jordan: A parental overview.
Alkhamra, Rana A
2015-07-01
Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (p<0.05). Despite the general satisfaction from the information quantity and quality prior to cochlear implant, parents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.
Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ
Chikar, Jennifer A.; Batts, Shelley A.; Pfingst, Bryan E.; Raphael, Yehoash
2009-01-01
Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament – labeled nerve processes within the scala tympani, and the spatial relationship between them. PMID:19428528
Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.
Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash
2009-05-15
Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.
Grieco-Calub, Tina M.; Litovsky, Ruth Y.
2010-01-01
Objectives To measure sound source localization in children who have sequential bilateral cochlear implants (BICIs); to determine if localization accuracy correlates with performance on a right-left discrimination task (i.e., spatial acuity); to determine if there is a measurable bilateral benefit on a sound source identification task (i.e., localization accuracy) by comparing performance under bilateral and unilateral listening conditions; to determine if sound source localization continues to improve with longer durations of bilateral experience. Design Two groups of children participated in this study: a group of 21 children who received BICIs in sequential procedures (5–14 years old) and a group of 7 typically-developing children with normal acoustic hearing (5 years old). Testing was conducted in a large sound-treated booth with loudspeakers positioned on a horizontal arc with a radius of 1.2 m. Children participated in two experiments that assessed spatial hearing skills. Spatial hearing acuity was assessed with a discrimination task in which listeners determined if a sound source was presented on the right or left side of center; the smallest angle at which performance on this task was reliably above chance is the minimum audible angle. Sound localization accuracy was assessed with a sound source identification task in which children identified the perceived position of the sound source from a multi-loudspeaker array (7 or 15); errors are quantified using the root-mean-square (RMS) error. Results Sound localization accuracy was highly variable among the children with BICIs, with RMS errors ranging from 19°–56°. Performance of the NH group, with RMS errors ranging from 9°–29° was significantly better. Within the BICI group, in 11/21 children RMS errors were smaller in the bilateral vs. unilateral listening condition, indicating bilateral benefit. There was a significant correlation between spatial acuity and sound localization accuracy (R2=0.68, p<0.01), suggesting that children who achieve small RMS errors tend to have the smallest MAAs. Although there was large intersubject variability, testing of 11 children in the BICI group at two sequential visits revealed a subset of children who show improvement in spatial hearing skills over time. Conclusions A subset of children who use sequential BICIs can acquire sound localization abilities, even after long intervals between activation of hearing in the first- and second-implanted ears. This suggests that children with activation of the second implant later in life may be capable of developing spatial hearing abilities. The large variability in performance among the children with BICIs suggests that maturation of sound localization abilities in children with BICIs may be dependent on various individual subject factors such as age of implantation and chronological age. PMID:20592615
Unilateral hearing during development: hemispheric specificity in plastic reorganizations
Kral, Andrej; Heid, Silvia; Hubka, Peter; Tillein, Jochen
2013-01-01
The present study investigates the hemispheric contributions of neuronal reorganization following early single-sided hearing (unilateral deafness). The experiments were performed on ten cats from our colony of deaf white cats. Two were identified in early hearing screening as unilaterally congenitally deaf. The remaining eight were bilaterally congenitally deaf, unilaterally implanted at different ages with a cochlear implant. Implanted animals were chronically stimulated using a single-channel portable signal processor for two to five months. Microelectrode recordings were performed at the primary auditory cortex under stimulation at the hearing and deaf ear with bilateral cochlear implants. Local field potentials (LFPs) were compared at the cortex ipsilateral and contralateral to the hearing ear. The focus of the study was on the morphology and the onset latency of the LFPs. With respect to morphology of LFPs, pronounced hemisphere-specific effects were observed. Morphology of amplitude-normalized LFPs for stimulation of the deaf and the hearing ear was similar for responses recorded at the same hemisphere. However, when comparisons were performed between the hemispheres, the morphology was more dissimilar even though the same ear was stimulated. This demonstrates hemispheric specificity of some cortical adaptations irrespective of the ear stimulated. The results suggest a specific adaptation process at the hemisphere ipsilateral to the hearing ear, involving specific (down-regulated inhibitory) mechanisms not found in the contralateral hemisphere. Finally, onset latencies revealed that the sensitive period for the cortex ipsilateral to the hearing ear is shorter than that for the contralateral cortex. Unilateral hearing experience leads to a functionally-asymmetric brain with different neuronal reorganizations and different sensitive periods involved. PMID:24348345
Unilateral hearing during development: hemispheric specificity in plastic reorganizations.
Kral, Andrej; Heid, Silvia; Hubka, Peter; Tillein, Jochen
2013-01-01
The present study investigates the hemispheric contributions of neuronal reorganization following early single-sided hearing (unilateral deafness). The experiments were performed on ten cats from our colony of deaf white cats. Two were identified in early hearing screening as unilaterally congenitally deaf. The remaining eight were bilaterally congenitally deaf, unilaterally implanted at different ages with a cochlear implant. Implanted animals were chronically stimulated using a single-channel portable signal processor for two to five months. Microelectrode recordings were performed at the primary auditory cortex under stimulation at the hearing and deaf ear with bilateral cochlear implants. Local field potentials (LFPs) were compared at the cortex ipsilateral and contralateral to the hearing ear. The focus of the study was on the morphology and the onset latency of the LFPs. With respect to morphology of LFPs, pronounced hemisphere-specific effects were observed. Morphology of amplitude-normalized LFPs for stimulation of the deaf and the hearing ear was similar for responses recorded at the same hemisphere. However, when comparisons were performed between the hemispheres, the morphology was more dissimilar even though the same ear was stimulated. This demonstrates hemispheric specificity of some cortical adaptations irrespective of the ear stimulated. The results suggest a specific adaptation process at the hemisphere ipsilateral to the hearing ear, involving specific (down-regulated inhibitory) mechanisms not found in the contralateral hemisphere. Finally, onset latencies revealed that the sensitive period for the cortex ipsilateral to the hearing ear is shorter than that for the contralateral cortex. Unilateral hearing experience leads to a functionally-asymmetric brain with different neuronal reorganizations and different sensitive periods involved.
Cochlear implants: system design, integration, and evaluation.
Zeng, Fan-Gang; Rebscher, Stephen; Harrison, William; Sun, Xiaoan; Feng, Haihong
2008-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.
Kandathil, Cherian K; Stakhovskaya, Olga; Leake, Patricia A
2016-12-01
Many previous studies have shown significant neurotrophic effects of intracochlear delivery of BDNF in preventing degeneration of cochlear spiral ganglion (SG) neurons after deafness in rodents and our laboratory has shown similar results in developing cats deafened prior to hearing onset. This study examined the morphology of the cochlear nucleus (CN) in a group of neonatally deafened cats from a previous study in which infusion of BDNF elicited a significant improvement in survival of the SG neurons. Five cats were deafened by systemic injections of neomycin sulfate (60 mg/kg, SQ, SID) starting one day after birth, and continuing for 16-18 days until auditory brainstem response (ABR) testing demonstrated profound bilateral hearing loss. The animals were implanted unilaterally at about 1 month of age using custom-designed electrodes with a drug-delivery cannula connected to an osmotic pump. BDNF (94 μg/ml; 0.25 μl/hr) was delivered for 10 weeks. The animals were euthanized and studied at 14-23 weeks of age. Consistent with the neurotrophic effects of BDNF on SG survival, the total CN volume in these animals was significantly larger on the BDNF-treated side than on the contralateral side. However, total CN volume, both ipsi- and contralateral to the implants in these deafened juvenile animals, was markedly smaller than the CN in normal adult animals, reflecting the severe effects of deafness on the central auditory system during development. Data from the individual major CN subdivisions (DCN, Dorsal Cochlear Nucleus; PVCN, Posteroventral Cochlear Nucleus; AVCN, Anteroventral Cochlear Nucleus) also were analyzed. A significant difference was observed between the BDNF-treated and control sides only in the AVCN. Measurements of the cross-sectional areas of spherical cells showed that cells were significantly larger in the AVCN ipsilateral to the implant than on the contralateral side. Further, the numerical density of spherical cells was significantly lower in the AVCN ipsilateral to the implant than on the contralateral side, consistent with the larger AVCN volume observed with BDNF treatment. Together, findings indicate significant neurotrophic effects of intracochlear BDNF infusion on the developing CN. Copyright © 2016 Elsevier B.V. All rights reserved.
Bharadwaj, Sneha V; Maricle, Denise; Green, Laura; Allman, Tamby
2015-10-01
The objective of the study was to examine short-term memory and working memory through both visual and auditory tasks in school-age children with cochlear implants. The relationship between the performance on these cognitive skills and reading as well as language outcomes were examined in these children. Ten children between the ages of 7 and 11 years with early-onset bilateral severe-profound hearing loss participated in the study. Auditory and visual short-term memory, auditory and visual working memory subtests and verbal knowledge measures were assessed using the Woodcock Johnson III Tests of Cognitive Abilities, the Wechsler Intelligence Scale for Children-IV Integrated and the Kaufman Assessment Battery for Children II. Reading outcomes were assessed using the Woodcock Reading Mastery Test III. Performance on visual short-term memory and visual working memory measures in children with cochlear implants was within the average range when compared to the normative mean. However, auditory short-term memory and auditory working memory measures were below average when compared to the normative mean. Performance was also below average on all verbal knowledge measures. Regarding reading outcomes, children with cochlear implants scored below average for listening and passage comprehension tasks and these measures were positively correlated to visual short-term memory, visual working memory and auditory short-term memory. Performance on auditory working memory subtests was not related to reading or language outcomes. The children with cochlear implants in this study demonstrated better performance in visual (spatial) working memory and short-term memory skills than in auditory working memory and auditory short-term memory skills. Significant positive relationships were found between visual working memory and reading outcomes. The results of the study provide support for the idea that WM capacity is modality specific in children with hearing loss. Based on these findings, reading instruction that capitalizes on the strengths in visual short-term memory and working memory is suggested for young children with early-onset hearing loss. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Luo, Xin; Fu, Qian-Jie; Galvin, John J.
2007-01-01
The present study investigated the ability of normal-hearing listeners and cochlear implant users to recognize vocal emotions. Sentences were produced by 1 male and 1 female talker according to 5 target emotions: angry, anxious, happy, sad, and neutral. Overall amplitude differences between the stimuli were either preserved or normalized. In experiment 1, vocal emotion recognition was measured in normal-hearing and cochlear implant listeners; cochlear implant subjects were tested using their clinically assigned processors. When overall amplitude cues were preserved, normal-hearing listeners achieved near-perfect performance, whereas listeners with cochlear implant recognized less than half of the target emotions. Removing the overall amplitude cues significantly worsened mean normal-hearing and cochlear implant performance. In experiment 2, vocal emotion recognition was measured in listeners with cochlear implant as a function of the number of channels (from 1 to 8) and envelope filter cutoff frequency (50 vs 400 Hz) in experimental speech processors. In experiment 3, vocal emotion recognition was measured in normal-hearing listeners as a function of the number of channels (from 1 to 16) and envelope filter cutoff frequency (50 vs 500 Hz) in acoustic cochlear implant simulations. Results from experiments 2 and 3 showed that both cochlear implant and normal-hearing performance significantly improved as the number of channels or the envelope filter cutoff frequency was increased. The results suggest that spectral, temporal, and overall amplitude cues each contribute to vocal emotion recognition. The poorer cochlear implant performance is most likely attributable to the lack of salient pitch cues and the limited functional spectral resolution. PMID:18003871
Sensitivity to binaural timing in bilateral cochlear implant users.
van Hoesel, Richard J M
2007-04-01
Various measures of binaural timing sensitivity were made in three bilateral cochlear implant users, who had demonstrated moderate-to-good interaural time delay (ITD) sensitivity at 100 pulses-per-second (pps). Overall, ITD thresholds increased at higher pulse rates, lower levels, and shorter durations, although intersubject differences were evident. Monaural rate-discrimination thresholds, using the same stimulation parameters, showed more substantial elevation than ITDs with increased rate. ITD sensitivity with 6000 pps stimuli, amplitude-modulated at 100 Hz, was similar to that with unmodulated pulse trains at 100 pps, but at 200 and 300 Hz performance was poorer than with unmodulated signals. Measures of sensitivity to binaural beats with unmodulated pulse-trains showed that all three subjects could use time-varying ITD cues at 100 pps, but not 300 pps, even though static ITD sensitivity was relatively unaffected over that range. The difference between static and dynamic ITD thresholds is discussed in terms of relative contributions from initial and later arriving cues, which was further examined in an experiment using two-pulse stimuli as a function of interpulse separation. In agreement with the binaural-beat data, findings from that experiment showed poor discrimination of ITDs on the second pulse when the interval between pulses was reduced to a few milliseconds.
Availability of binaural cues for pediatric bilateral cochlear implant recipients.
Sheffield, Sterling W; Haynes, David S; Wanna, George B; Labadie, Robert F; Gifford, René H
2015-03-01
Bilateral implant recipients theoretically have access to binaural cues. Research in postlingually deafened adults with cochlear implants (CIs) indicates minimal evidence for true binaural hearing. Congenitally deafened children who experience spatial hearing with bilateral CIs, however, might perceive binaural cues in the CI signal differently. There is limited research examining binaural hearing in children with CIs, and the few published studies are limited by the use of unrealistic speech stimuli and background noise. The purposes of this study were to (1) replicate our previous study of binaural hearing in postlingually deafened adults with AzBio sentences in prelingually deafened children with the pediatric version of the AzBio sentences, and (2) replicate previous studies of binaural hearing in children with CIs using more open-set sentences and more realistic background noise (i.e., multitalker babble). The study was a within-participant, repeated-measures design. The study sample consisted of 14 children with bilateral CIs with at least 25 mo of listening experience. Speech recognition was assessed using sentences presented in multitalker babble at a fixed signal-to-noise ratio. Test conditions included speech at 0° with noise presented at 0° (S0N0), on the side of the first CI (90° or 270°) (S0N1stCI), and on the side of the second CI (S0N2ndCI) as well as speech presented at 0° with noise presented semidiffusely from eight speakers at 45° intervals. Estimates of summation, head shadow, squelch, and spatial release from masking were calculated. Results of test conditions commonly reported in the literature (S0N0, S0N1stCI, S0N2ndCI) are consistent with results from previous research in adults and children with bilateral CIs, showing minimal summation and squelch but typical head shadow and spatial release from masking. However, bilateral benefit over the better CI with speech at 0° was much larger with semidiffuse noise. Congenitally deafened children with CIs have similar availability of binaural hearing cues to postlingually deafened adults with CIs within the same experimental design. It is possible that the use of realistic listening environments, such as semidiffuse background noise as in Experiment II, would reveal greater binaural hearing benefit for bilateral CI recipients. Future research is needed to determine whether (1) availability of binaural cues for children correlates with interaural time and level differences, (2) different listening environments are more sensitive to binaural hearing benefits, and (3) differences exist between pediatric bilateral recipients receiving implants in the same or sequential surgeries. American Academy of Audiology.
[Emotional response to music by postlingually-deafened adult cochlear implant users].
Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo
2012-10-01
To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.
Guideline on cochlear implants.
Manrique, Manuel; Ramos, Ángel; de Paula Vernetta, Carlos; Gil-Carcedo, Elisa; Lassaleta, Luis; Sanchez-Cuadrado, Isabel; Espinosa, Juan Manuel; Batuecas, Ángel; Cenjor, Carlos; Lavilla, María José; Núñez, Faustino; Cavalle, Laura; Huarte, Alicia
2018-03-26
In the last decade numerous hospitals have started to work with patients who are candidates for a cochlear implant (CI) and there have been numerous and relevant advances in the treatment of sensorineural hearing loss that extended the indications for cochlear implants. To provide a guideline on cochlear implants to specialists in otorhinolaryngology, other medical specialities, health authorities and society in general. The Scientific Committees of Otology, Otoneurology and Audiology from the Spanish Society of Otolaryngology and Head and Neck Surgery (SEORL-CCC), in a coordinated and agreed way, performed a review of the current state of CI based on the existing regulations and in the scientific publications referenced in the bibliography of the document drafted. The clinical guideline on cochlear implants provides information on: a) Definition and description of Cochlear Implant; b) Indications for cochlear implants; c) Organizational requirements for a cochlear implant programme. A clinical guideline on cochlear implants has been developed by a Committee of Experts of the SEORL-CCC, to help and guide all the health professionals involved in this field of CI in decision-making to treathearing impairment. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.
Working memory in Farsi-speaking children with normal development and cochlear implant.
Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre
2014-04-01
Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p < 0.001). The children's age at implantation was negatively correlated with all tasks (p < 0.001). In contrast, duration of usage of cochlear implant set was positively correlated with all tasks (p < 0.001). The comparison of working memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p < 0.05). These results implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Agile Development of Advanced Prototypes
2014-11-01
prostheses: retinal implants, cochlear implants, and neuroprosthetics (EEG controlled artificial limbs); an interactive, virtual experience...demonstrations allowing users to experience, from a patient’s perspective life with three different prostheses: retinal implants, cochlear implants...three experiences were researched and developed. The applications are interactive demonstrations of retinal implants, cochlear implants, and
Cochlear Implants:System Design, Integration and Evaluation
Rebscher, Stephen; Harrison, William V.; Sun, Xiaoan; Feng, Haihong
2009-01-01
As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120,000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues from design and specifications to integration and evaluation. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants. PMID:19946565
Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M
2012-06-01
The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Cochlear implant in Hong Kong Cantonese.
Tang, S O; Luk, W S; Lau, C C; So, K W; Wong, C M; Yiu, M L; Kwok, C L
1990-11-01
Cochlear implant surgery was performed in four Cantonese-speaking postlingually deaf Chinese adults, using the House/3M single channel device. This article outlines the methodology, including preoperative assessment and postoperative rehabilitation; and explains the necessary modifications in speech and audiologic work-up in Cantonese-speaking patients. Salient features of Cantonese phonetics, especially its tonal characteristics, are described. The findings of the study are presented. The results of the cochlear implant would suggest a performance superior to that of the hearing aid. Furthermore, the cochlear implant is able to detect tonal cues. This quality of the cochlear implant may prove to be a valuable asset to a tonal language-speaking cochlear implantee.
Binaural interaction in the auditory brainstem response: a normative study.
Van Yper, Lindsey N; Vermeire, Katrien; De Vel, Eddy F J; Battmer, Rolf-Dieter; Dhooge, Ingeborg J M
2015-04-01
Binaural interaction can be investigated using auditory evoked potentials. A binaural interaction component can be derived from the auditory brainstem response (ABR-BIC) and is considered evidence for binaural interaction at the level of the brainstem. Although click ABR-BIC has been investigated thoroughly, data on 500 Hz tone-burst (TB) ABR-BICs are scarce. In this study, characteristics of click and 500 Hz TB ABR-BICs are described. Furthermore, reliability of both click and 500 Hz TB ABR-BIC are investigated. Eighteen normal hearing young adults (eight women, ten men) were included. ABRs were recorded in response to clicks and 500 Hz TBs. ABR-BICs were derived by subtracting the binaural response from the sum of the monaural responses measured in opposite ears. Good inter-rater reliability is obtained for both click and 500 Hz TB ABR-BICs. The most reliable peak in click ABR-BIC occurs at a mean latency of 6.06 ms (SD 0.354 ms). Reliable 500 Hz TB ABR-BIC are obtained with a mean latency of 9.47 ms (SD 0.678 ms). Amplitudes are larger for 500 Hz TB ABR-BIC than for clicks. The most reliable peak in click ABR-BIC occurs at the downslope of wave V. Five hundred Hertz TB ABR-BIC is characterized by a broad positivity occurring at the level of wave V. The ABR-BIC is a useful technique to investigate binaural interaction in certain populations. Examples are bilateral hearing aid users, bilateral cochlear implant users and bimodal listeners. The latter refers to the combination of unilateral cochlear implantation and contralateral residual hearing. The majority of these patients have residual hearing in the low frequencies. The current study suggests that 500 Hz TB ABR-BIC may be a suitable technique to assess binaural interaction in this specific population of cochlear implant users. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Eustaquio-Martín, Almudena; Stohl, Joshua S.; Wolford, Robert D.; Schatzer, Reinhold; Wilson, Blake S.
2016-01-01
Objectives: In natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources. Design: Pairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased/increased dynamically (so that output levels dropped/increased) with increases/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors. Results: In both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy. Conclusions: The MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids. PMID:26862711
Lopez-Poveda, Enrique A; Eustaquio-Martín, Almudena; Stohl, Joshua S; Wolford, Robert D; Schatzer, Reinhold; Wilson, Blake S
2016-01-01
In natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources. Pairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased/increased dynamically (so that output levels dropped/increased) with increases/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors. In both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy. The MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management. PMID:15247993
Adiloğlu, K.; Herzke, T.
2015-01-01
We present the first portable, binaural, real-time research platform compatible with Oticon Medical SP and XP generation cochlear implants. The platform consists of (a) a pair of behind-the-ear devices, each containing front and rear calibrated microphones, (b) a four-channel USB analog-to-digital converter, (c) real-time PC-based sound processing software called the Master Hearing Aid, and (d) USB-connected hardware and output coils capable of driving two implants simultaneously. The platform is capable of processing signals from the four microphones simultaneously and producing synchronized binaural cochlear implant outputs that drive two (bilaterally implanted) SP or XP implants. Both audio signal preprocessing algorithms (such as binaural beamforming) and novel binaural stimulation strategies (within the implant limitations) can be programmed by researchers. When the whole research platform is combined with Oticon Medical SP implants, interaural electrode timing can be controlled on individual electrodes to within ±1 µs and interaural electrode energy differences can be controlled to within ±2%. Hence, this new platform is particularly well suited to performing experiments related to interaural time differences in combination with interaural level differences in real-time. The platform also supports instantaneously variable stimulation rates and thereby enables investigations such as the effect of changing the stimulation rate on pitch perception. Because the processing can be changed on the fly, researchers can use this platform to study perceptual changes resulting from different processing strategies acutely. PMID:26721923
Backus, B; Adiloğlu, K; Herzke, T
2015-12-30
We present the first portable, binaural, real-time research platform compatible with Oticon Medical SP and XP generation cochlear implants. The platform consists of (a) a pair of behind-the-ear devices, each containing front and rear calibrated microphones, (b) a four-channel USB analog-to-digital converter, (c) real-time PC-based sound processing software called the Master Hearing Aid, and (d) USB-connected hardware and output coils capable of driving two implants simultaneously. The platform is capable of processing signals from the four microphones simultaneously and producing synchronized binaural cochlear implant outputs that drive two (bilaterally implanted) SP or XP implants. Both audio signal preprocessing algorithms (such as binaural beamforming) and novel binaural stimulation strategies (within the implant limitations) can be programmed by researchers. When the whole research platform is combined with Oticon Medical SP implants, interaural electrode timing can be controlled on individual electrodes to within ±1 µs and interaural electrode energy differences can be controlled to within ±2%. Hence, this new platform is particularly well suited to performing experiments related to interaural time differences in combination with interaural level differences in real-time. The platform also supports instantaneously variable stimulation rates and thereby enables investigations such as the effect of changing the stimulation rate on pitch perception. Because the processing can be changed on the fly, researchers can use this platform to study perceptual changes resulting from different processing strategies acutely. © The Author(s) 2015.
Spectrum of temporal bone abnormalities in patients with Waardenburg syndrome and SOX10 mutations.
Elmaleh-Bergès, M; Baumann, C; Noël-Pétroff, N; Sekkal, A; Couloigner, V; Devriendt, K; Wilson, M; Marlin, S; Sebag, G; Pingault, V
2013-01-01
Waardenburg syndrome, characterized by deafness and pigmentation abnormalities, is clinically and genetically heterogeneous, consisting of 4 distinct subtypes and involving several genes. SOX10 mutations have been found both in types 2 and 4 Waardenburg syndrome and neurologic variants. The purpose of this study was to evaluate both the full spectrum and relative frequencies of inner ear malformations in these patients. Fifteen patients with Waardenburg syndrome and different SOX10 mutations were studied retrospectively. Imaging was performed between February 2000 and March 2010 for cochlear implant work-up, diagnosis of hearing loss, and/or evaluation of neurologic impairment. Eleven patients had both CT and MR imaging examinations, 3 had MR imaging only, and 1 had CT only. Temporal bone abnormalities were bilateral. The most frequent pattern associated agenesis or hypoplasia of ≥1 semicircular canal, an enlarged vestibule, and a cochlea with a reduced size and occasionally an abnormal shape, but with normal partition in the 13/15 cases that could be analyzed. Three patients lacked a cochlear nerve, bilaterally in 2 patients. In addition, associated abnormalities were found when adequate MR imaging sequences were available: agenesis of the olfactory bulbs (7/8), hypoplastic or absent lacrimal glands (11/14), hypoplastic parotid glands (12/14), and white matter signal anomalies (7/13). In the appropriate clinical context, bilateral agenesis or hypoplasia of the semicircular canals or both, associated with an enlarged vestibule and a cochlear deformity, strongly suggests a diagnosis of Waardenburg syndrome linked to a SOX10 mutation.
International classification of reliability for implanted cochlear implant receiver stimulators.
Battmer, Rolf-Dieter; Backous, Douglas D; Balkany, Thomas J; Briggs, Robert J S; Gantz, Bruce J; van Hasselt, Andrew; Kim, Chong Sun; Kubo, Takeshi; Lenarz, Thomas; Pillsbury, Harold C; O'Donoghue, Gerard M
2010-10-01
To design an international standard to be used when reporting reliability of the implanted components of cochlear implant systems to appropriate governmental authorities, cochlear implant (CI) centers, and for journal editors in evaluating manuscripts involving cochlear implant reliability. The International Consensus Group for Cochlear Implant Reliability Reporting was assembled to unify ongoing efforts in the United States, Europe, Asia, and Australia to create a consistent and comprehensive classification system for the implanted components of CI systems across manufacturers. All members of the consensus group are from tertiary referral cochlear implant centers. None. A clinically relevant classification scheme adapted from principles of ISO standard 5841-2:2000 originally designed for reporting reliability of cardiac pacemakers, pulse generators, or leads. Standard definitions for device failure, survival time, clinical benefit, reduced clinical benefit, and specification were generated. Time intervals for reporting back to implant centers for devices tested to be "out of specification," categorization of explanted devices, the method of cumulative survival reporting, and content of reliability reports to be issued by manufacturers was agreed upon by all members. The methodology for calculating Cumulative survival was adapted from ISO standard 5841-2:2000. The International Consensus Group on Cochlear Implant Device Reliability Reporting recommends compliance to this new standard in reporting reliability of implanted CI components by all manufacturers of CIs and the adoption of this standard as a minimal reporting guideline for editors of journals publishing cochlear implant research results.
[The development of musicality in children after cochlear implantation].
Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing
2014-08-01
The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (P<0.05). The mean scores of musicality also showed significant improvements with time for control group (P<0.05). There were no significant differences in mean scores between CI group and control group at 1, 3, 6, 9, 12 months of hearing age by rank sum test (P>0.05). Significant difference was noted between the two groups at 24 months (P<0.05). The musicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.
Remote programming of cochlear implants: a telecommunications model.
McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S
2010-09-01
Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.
Music mixing preferences of cochlear implant recipients: a pilot study.
Buyens, Wim; van Dijk, Bas; Moonen, Marc; Wouters, Jan
2014-05-01
Music perception and appraisal are generally poor in cochlear implant recipients. Simple musical structures, lyrics that are easy to follow, and clear rhythm/beat have been reported among the top factors to enhance music enjoyment. The present study investigated the preference for modified relative instrument levels in music with normal-hearing and cochlear implant subjects. In experiment 1, test subjects were given a mixing console and multi-track recordings to determine their most enjoyable audio mix. In experiment 2, a preference rating experiment based on the preferred relative level settings in experiment 1 was performed. Experiment 1 was performed with four postlingually deafened cochlear implant subjects, experiment 2 with ten normal-hearing and ten cochlear implant subjects. A significant difference in preference rating was found between normal-hearing and cochlear implant subjects. The latter preferred an audio mix with larger vocals-to-instruments ratio. In addition, given an audio mix with clear vocals and attenuated instruments, cochlear implant subjects preferred the bass/drum track to be louder than the other instrument tracks. The original audio mix in real-world music might not be suitable for cochlear implant recipients. Modifying the relative instrument level settings potentially improves music enjoyment.
A Challenge for Cochlear Implantation: Duplicated Internal Auditory Canal.
Binnetoğlu, Adem; Bağlam, Tekin; Sarı, Murat; Gündoğdu, Yavuz; Batman, Çağlar
2016-08-01
Duplication of the internal auditory canal is an uncommon, congenital malformation that can be associated with sensorineural hearing loss owing to aplasia/hypoplasia of the vestibulocochlear nerve. Only 14 such cases have been reported to date. We report the case of a 13-month-old girl with bilateral, congenital, sensorineural hearing loss caused by narrow, duplicated internal auditory canals and discuss the challenges encountered in the diagnosis and treatment of this condition.
Importance of cochlear health for implant function.
Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A
2015-04-01
Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled
Impact of a Moving Noise Masker on Speech Perception in Cochlear Implant Users
Weissgerber, Tobias; Rader, Tobias; Baumann, Uwe
2015-01-01
Objectives Previous studies investigating speech perception in noise have typically been conducted with static masker positions. The aim of this study was to investigate the effect of spatial separation of source and masker (spatial release from masking, SRM) in a moving masker setup and to evaluate the impact of adaptive beamforming in comparison with fixed directional microphones in cochlear implant (CI) users. Design Speech reception thresholds (SRT) were measured in S0N0 and in a moving masker setup (S0Nmove) in 12 normal hearing participants and 14 CI users (7 subjects bilateral, 7 bimodal with a hearing aid in the contralateral ear). Speech processor settings were a moderately directional microphone, a fixed beamformer, or an adaptive beamformer. The moving noise source was generated by means of wave field synthesis and was smoothly moved in a shape of a half-circle from one ear to the contralateral ear. Noise was presented in either of two conditions: continuous or modulated. Results SRTs in the S0Nmove setup were significantly improved compared to the S0N0 setup for both the normal hearing control group and the bilateral group in continuous noise, and for the control group in modulated noise. There was no effect of subject group. A significant effect of directional sensitivity was found in the S0Nmove setup. In the bilateral group, the adaptive beamformer achieved lower SRTs than the fixed beamformer setting. Adaptive beamforming improved SRT in both CI user groups substantially by about 3 dB (bimodal group) and 8 dB (bilateral group) depending on masker type. Conclusions CI users showed SRM that was comparable to normal hearing subjects. In listening situations of everyday life with spatial separation of source and masker, directional microphones significantly improved speech perception with individual improvements of up to 15 dB SNR. Users of bilateral speech processors with both directional microphones obtained the highest benefit. PMID:25970594
Development of Sound Localization Strategies in Children with Bilateral Cochlear Implants
Zheng, Yi; Godar, Shelly P.; Litovsky, Ruth Y.
2015-01-01
Localizing sounds in our environment is one of the fundamental perceptual abilities that enable humans to communicate, and to remain safe. Because the acoustic cues necessary for computing source locations consist of differences between the two ears in signal intensity and arrival time, sound localization is fairly poor when a single ear is available. In adults who become deaf and are fitted with cochlear implants (CIs) sound localization is known to improve when bilateral CIs (BiCIs) are used compared to when a single CI is used. The aim of the present study was to investigate the emergence of spatial hearing sensitivity in children who use BiCIs, with a particular focus on the development of behavioral localization patterns when stimuli are presented in free-field horizontal acoustic space. A new analysis was implemented to quantify patterns observed in children for mapping acoustic space to a spatially relevant perceptual representation. Children with normal hearing were found to distribute their responses in a manner that demonstrated high spatial sensitivity. In contrast, children with BiCIs tended to classify sound source locations to the left and right; with increased bilateral hearing experience, they developed a perceptual map of space that was better aligned with the acoustic space. The results indicate experience-dependent refinement of spatial hearing skills in children with CIs. Localization strategies appear to undergo transitions from sound source categorization strategies to more fine-grained location identification strategies. This may provide evidence for neural plasticity, with implications for training of spatial hearing ability in CI users. PMID:26288142
Development of Sound Localization Strategies in Children with Bilateral Cochlear Implants.
Zheng, Yi; Godar, Shelly P; Litovsky, Ruth Y
2015-01-01
Localizing sounds in our environment is one of the fundamental perceptual abilities that enable humans to communicate, and to remain safe. Because the acoustic cues necessary for computing source locations consist of differences between the two ears in signal intensity and arrival time, sound localization is fairly poor when a single ear is available. In adults who become deaf and are fitted with cochlear implants (CIs) sound localization is known to improve when bilateral CIs (BiCIs) are used compared to when a single CI is used. The aim of the present study was to investigate the emergence of spatial hearing sensitivity in children who use BiCIs, with a particular focus on the development of behavioral localization patterns when stimuli are presented in free-field horizontal acoustic space. A new analysis was implemented to quantify patterns observed in children for mapping acoustic space to a spatially relevant perceptual representation. Children with normal hearing were found to distribute their responses in a manner that demonstrated high spatial sensitivity. In contrast, children with BiCIs tended to classify sound source locations to the left and right; with increased bilateral hearing experience, they developed a perceptual map of space that was better aligned with the acoustic space. The results indicate experience-dependent refinement of spatial hearing skills in children with CIs. Localization strategies appear to undergo transitions from sound source categorization strategies to more fine-grained location identification strategies. This may provide evidence for neural plasticity, with implications for training of spatial hearing ability in CI users.
Cochlear implants in Waardenburg syndrome.
Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig
2006-07-01
Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.
Mertens, Griet; Van Rompaey, Vincent; Van de Heyning, Paul
2018-05-17
A suggested solution to suppress tinnitus is to restore the normal sensory input. This is based on the auditory deprivation hypothesis. It is known that hearing aids can provide sufficient activation of the auditory nervous system and reduce tinnitus in subjects with mild to moderate hearing loss and that cochlear implantation can reduce tinnitus in subjects with severe to profound hearing loss. This applies to subjects with single-sided deafness (SSD) or bilateral hearing loss. To investigate if electric-acoustic stimulation (EAS) can reduce severe tinnitus in a subject with residual hearing in the ipsilateral ear and contralateral normal hearing (high-frequency SSD) by restoring the auditory input. Tinnitus reduction was investigated for 1 year after implantation in a subject with high-frequency SSD, who uses EAS, and was compared to 11 subjects with a cochlear implant (CI) with SSD. The Visual Analogue Scale (VAS) and the Tinnitus Questionnaire (TQ) were administered pre-operatively and at 1, 3, 6, and 12 months after implantation. Significant tinnitus reduction was observed 1 month after implantation on the VAS in the subjects with SSD using a CI. Tinnitus reduction was also observed in the subject with high-frequency SSD using EAS. A further decrease was observed 3 months after implantation. The TQ and VAS scores remained stable up to 1 year after implantation. A CI can significantly reduce ipsilateral severe tinnitus in a subject with SSD. Ipsilateral severe tinnitus can also be reduced using EAS in subjects with high-frequency SSD.
Monshizadeh, Leila; Vameghi, Roshanak; Sajedi, Firoozeh; Yadegari, Fariba; Hashemi, Seyed Basir; Kirchem, Petra; Kasbi, Fatemeh
2018-04-01
A cochlear implant is a device that helps hearing-impaired children by transmitting sound signals to the brain and helping them improve their speech, language, and social interaction. Although various studies have investigated the different aspects of speech perception and language acquisition in cochlear-implanted children, little is known about their social skills, particularly Persian-speaking cochlear-implanted children. Considering the growing number of cochlear implants being performed in Iran and the increasing importance of developing near-normal social skills as one of the ultimate goals of cochlear implantation, this study was performed to compare the social interaction between Iranian cochlear-implanted children who have undergone rehabilitation (auditory verbal therapy) after surgery and normal-hearing children. This descriptive-analytical study compared the social interaction level of 30 children with normal hearing and 30 with cochlear implants who were conveniently selected. The Raven test was administered to the both groups to ensure normal intelligence quotient. The social interaction status of both groups was evaluated using the Vineland Adaptive Behavior Scale, and statistical analysis was performed using Statistical Package for Social Sciences (SPSS) version 21. After controlling age as a covariate variable, no significant difference was observed between the social interaction scores of both the groups (p > 0.05). In addition, social interaction had no correlation with sex in either group. Cochlear implantation followed by auditory verbal rehabilitation helps children with sensorineural hearing loss to have normal social interactions, regardless of their sex.
Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.
Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo
2017-09-01
to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.
Staisloff, Hannah E; Lee, Daniel H; Aronoff, Justin M
2016-07-01
For bilateral cochlear implant users, the left and right arrays are typically not physically aligned, resulting in a degradation of binaural fusion, which can be detrimental to binaural abilities. Perceptually aligning the two arrays can be accomplished by disabling electrodes in one ear that do not have a perceptually corresponding electrode in the other side. However, disabling electrodes at the edges of the array will cause compression of the input frequency range into a smaller cochlear extent, which may result in reduced spectral resolution. An alternative approach to overcome this mismatch would be to only align one edge of the array. By aligning either only the apical or basal end of the arrays, fewer electrodes would be disabled, potentially causing less reduction in spectral resolution. The goal of this study was to determine the relative effect of aligning either the basal or apical end of the electrode with regards to binaural fusion. A vocoder was used to simulate cochlear implant listening conditions in normal hearing listeners. Speech signals were vocoded such that the two ears were either predominantly aligned at only the basal or apical end of the simulated arrays. The experiment was then repeated with a spectrally inverted vocoder to determine whether the detrimental effects on fusion were related to the spectral-temporal characteristics of the stimuli or the location in the cochlea where the misalignment occurred. In Experiment 1, aligning the basal portion of the simulated arrays led to significantly less binaural fusion than aligning the apical portions of the simulated array. However, when the input was spectrally inverted, aligning the apical portion of the simulated array led to significantly less binaural fusion than aligning the basal portions of the simulated arrays. These results suggest that, for speech, with its predominantly low frequency spectral-temporal modulations, it is more important to perceptually align the apical portion of the array to better preserve binaural fusion. By partially aligning these arrays, cochlear implant users could potentially increase their ability to fuse speech sounds presented to the two ears while maximizing spectral resolution. Copyright © 2016 Elsevier B.V. All rights reserved.
[Cochlear implantation in patients with Waardenburg syndrome type II].
Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian
2010-05-01
To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.
Arnold, W; Bredberg, G; Gstöttner, W; Helms, J; Hildmann, H; Kiratzidis, T; Müller, J; Ramsden, R T; Roland, P; Walterspiel, J N
2002-01-01
Pneumococcal otogenic meningitis is a rare postsurgical complication that can develop following stapedectomy or after cochlear implantation. The bacterial infection can be fatal in some instances. A recent increase in the incidence of otogenic meningitis among cochlear implant wearers is of concern. The majority of meningitis cases are associated with a 2-component electrode manufactured by one cochlear implant company. The device with the added 'positioner' component has been withdrawn from the market (FDA Public Health Web Notification: Cochlear Implant Recipients may be at Greater Risk for Meningitis, Updated: August 29, 2002, www.fda.gov/cdrh/safety/cochlear.html). Not all cases have been subsequent to otitis media and symptoms have developed from less than 24 h up to a few years after implantation. The purpose of this paper is to review and discuss the pathogenesis, pathology/bacteriology and to elaborate on some clinical features of otogenic meningitis in implanted children and adults. Essential aspects of surgery, electrode design, and cochleostomy seal are discussed. Conclusions are drawn from the available data and recommendations are made for good practice in cochlear implantation and follow-up. Copyright 2002 S. Karger AG, Basel
Jones, Heath G; Kan, Alan; Litovsky, Ruth Y
2016-01-01
This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.
Moein, Narges; Khoddami, Seyyedeh Maryam; Shahbodaghi, Mohammad Rahim
2017-10-01
Cochlear implant prosthesis facilitates spoken language development and speech comprehension in children with severe-profound hearing loss. However, this prosthesis is limited in encoding information about fundamental frequency and pitch that are essentially for recognition of speech prosody. The purpose of the present study is to investigate the perception and production of intonation in cochlear implant children and comparison with normal hearing children. This study carried out on 25 cochlear implanted children and 50 children with normal hearing. First, using 10 action pictures statements and questions sentences were extracted. Fundamental frequency and pitch changes were identified using Praat software. Then, these sentences were judged by 7 adult listeners. In second stage 20 sentences were played for child and he/she determined whether it was in a question form or statement one. Performance of cochlear implanted children in perception and production of intonation was significantly lower than children with normal hearing. The difference between fundamental frequency and pitch changes in cochlear implanted children and children with normal hearing was significant (P < 0/05). Cochlear implanted children performance in perception and production of intonation has significant correlation with child's age surgery and duration of prosthesis use (P < 0/05). The findings of the current study show that cochlear prostheses have limited application in facilitating the perception and production of intonation in cochlear implanted children. It should be noted that the child's age at the surgery and duration of prosthesis's use is important in reduction of this limitation. According to these findings, speech and language pathologists should consider intervention of intonation in treatment program of cochlear implanted children. Copyright © 2017 Elsevier B.V. All rights reserved.
The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.
Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya
2016-01-01
Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.
The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome
Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya
2016-01-01
Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome. PMID:27376080
Investigations in mechanisms and strategies to enhance hearing with cochlear implants
NASA Astrophysics Data System (ADS)
Churchill, Tyler H.
Cochlear implants (CIs) produce hearing sensations by stimulating the auditory nerve (AN) with current pulses whose amplitudes are modulated by filtered acoustic temporal envelopes. While this technology has provided hearing for multitudinous CI recipients, even bilaterally-implanted listeners have more difficulty understanding speech in noise and localizing sounds than normal hearing (NH) listeners. Three studies reported here have explored ways to improve electric hearing abilities. Vocoders are often used to simulate CIs for NH listeners. Study 1 was a psychoacoustic vocoder study examining the effects of harmonic carrier phase dispersion and simulated CI current spread on speech intelligibility in noise. Results showed that simulated current spread was detrimental to speech understanding and that speech vocoded with carriers whose components' starting phases were equal was the least intelligible. Cross-correlogram analyses of AN model simulations confirmed that carrier component phase dispersion resulted in better neural envelope representation. Localization abilities rely on binaural processing mechanisms in the brainstem and mid-brain that are not fully understood. In Study 2, several potential mechanisms were evaluated based on the ability of metrics extracted from stereo AN simulations to predict azimuthal locations. Results suggest that unique across-frequency patterns of binaural cross-correlation may provide a strong cue set for lateralization and that interaural level differences alone cannot explain NH sensitivity to lateral position. While it is known that many bilateral CI users are sensitive to interaural time differences (ITDs) in low-rate pulsatile stimulation, most contemporary CI processing strategies use high-rate, constant-rate pulse trains. In Study 3, we examined the effects of pulse rate and pulse timing on ITD discrimination, ITD lateralization, and speech recognition by bilateral CI listeners. Results showed that listeners were able to use low-rate pulse timing cues presented redundantly on multiple electrodes for ITD discrimination and lateralization of speech stimuli even when mixed with high rates on other electrodes. These results have contributed to a better understanding of those aspects of the auditory system that support speech understanding and binaural hearing, suggested vocoder parameters that may simulate aspects of electric hearing, and shown that redundant, low-rate pulse timing supports improved spatial hearing for bilateral CI listeners.
Davidson, Lisa S; Geers, Ann E; Brenner, Christine
2010-10-01
Updated cochlear implant technology and optimized fitting can have a substantial impact on speech perception. The effects of upgrades in processor technology and aided thresholds on word recognition at soft input levels and sentence recognition in noise were examined. We hypothesized that updated speech processors and lower aided thresholds would allow improved recognition of soft speech without compromising performance in noise. 109 teenagers who had used a Nucleus 22-cochlear implant since preschool were tested with their current speech processor(s) (101 unilateral and 8 bilateral): 13 used the Spectra, 22 the ESPrit 22, 61 the ESPrit 3G, and 13 the Freedom. The Lexical Neighborhood Test (LNT) was administered at 70 and 50 dB SPL and the Bamford Kowal Bench sentences were administered in quiet and in noise. Aided thresholds were obtained for frequency-modulated tones from 250 to 4,000 Hz. Results were analyzed using repeated measures analysis of variance. Aided thresholds for the Freedom/3G group were significantly lower (better) than the Spectra/Sprint group. LNT scores at 50 dB were significantly higher for the Freedom/3G group. No significant differences between the 2 groups were found for the LNT at 70 or sentences in quiet or noise. Adolescents using updated processors that allowed for aided detection thresholds of 30 dB HL or better performed the best at soft levels. The BKB in noise results suggest that greater access to soft speech does not compromise listening in noise.
Evaluating cochlear implant trauma to the scala vestibuli.
Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W
2005-04-01
Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.
Cochlear implantation for single-sided deafness and tinnitus suppression.
Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George
To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.
Greaver, Laura; Eskridge, Hannah; Teagle, Holly F B
2017-06-13
The purpose of this clinical report is to present case studies of children who are nontraditional candidates for cochlear implantation because they have significant residual hearing in 1 ear and to describe outcomes and considerations for their audiological management and habilitation. Case information is presented for 5 children with profound hearing loss in 1 ear and normal or mild-to-moderate hearing loss in the opposite ear and who have undergone unilateral cochlear implantation. Pre- and postoperative assessments were performed per typical clinic routines with modifications described. Postimplant habilitation was customized for each recipient using a combination of traditional methods, newer technologies, and commercial materials. The 5 children included in this report are consistent users of their cochlear implants and demonstrate speech recognition in the implanted ear when isolated from the better hearing ear. Candidacy criteria for cochlear implantation are evolving. Children with single-sided deafness or asymmetric hearing loss who have traditionally not been considered candidates for cochlear implantation should be evaluated on a case-by-case basis. Audiological management of these recipients is not vastly different compared with children who are traditional cochlear implant recipients. Assessment and habilitation techniques must be modified to isolate the implanted ear to obtain accurate results and to provide meaningful therapeutic intervention.
Lin, Yung-Song
2009-03-01
Cochlear implantation via the scala vestibuli is a viable approach in those with ossification in the scala tympani. With extended cochlear implant experience, there is no significant difference in the mapping parameters and auditory performance between those implanted via scala vestibuli and via scala tympani. To assess the clinical outcomes of cochlear implantation via scala vestibuli. In a cohort follow-up study, 11 prelingually deafened children who received cochlear implantation between age 3 and 10 years through the scala vestibuli served as participants. The mapping parameters (i.e. comfortable level (C), threshold level (T), dynamic range) and auditory performance of each participant were evaluated following initial cochlear implant stimulation, then at 3 month intervals for 2 years, then semi-annually. The follow-up period lasted for 9 years 9 months on average, with a minimum of 8 years 3 months. The clinical results of the mapping parameters and auditory performance of children implanted via the scala vestibuli were comparative to those who were implanted via the scala tympani. No balance problem was reported by any of these patients. One child exhibited residual low frequency hearing after implantation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shipsey, Ian
In his talk, Shipsey will discuss the cochlear implant, the first device to successfully allow the profoundly deaf to regain some sense of hearing. A cochlear implant is a small electronic apparatus. Unlike a normal hearing aid, which amplifies sound, a cochlear implant is surgically implanted behind the ear where it converts sound waves into electrical impulses. These implants have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. Shipsey will discuss the physiology of natural hearing from the perspective of a physicist. He willmore » also touch on the function of cochlear implants in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. Finally, Shipsey will address the social implications of cochlear implantation and the future outlook for auditory prostheses.« less
Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn
2016-11-01
This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pediatric Cochlear Implants: An Overview of the Alternatives in Education and Rehabilitation.
ERIC Educational Resources Information Center
Barnes, Judith M., Ed.; And Others
This collection of 10 papers is intended as a resource book integrating information on pediatric cochlear implants for educators, parents, implant teams, and rehabilitation specialists. The papers focus on the importance of providing an oral educational environment to maximize cochlear implant success. An introduction notes controversies in the…
Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet
ERIC Educational Resources Information Center
Searls, J. Matt, Comp.
2010-01-01
Cochlear implants (CIs) are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of individuals with significant permanent hearing loss. Cochlear implants may not be suitable for everyone. They are designed to provide…
The impact of ethnicity on cochlear implantation in Norwegian children.
Amundsen, Viktoria Vedeler; Wie, Ona Bø; Myhrum, Marte; Bunne, Marie
2017-02-01
To explore the impact of parental ethnicity on cochlear implantation in children in Norway with regard to incidence rates of cochlear implants (CIs), comorbidies, age at onset of profound deafness (AOD), age at first implantation, uni- or bilateral CI, and speech recognition. This retrospective cohort study included all children (N = 278) aged <18 years in Norway who received their first CI during the years 2004-2010. 86 children (30.9%) in our study sample had parents of non-Nordic ethnicity, of whom 46 were born in Nordic countries with two non-Nordic parents. Compared with the background population, children with non-Nordic parents were 1.9 times more likely to have received CI than Nordic children (i.e., born in Nordic countries with Nordic parents). When looking at AOD, uni-vs. bilateral CIs, and comorbidities, no significant differences were found between Nordic children and children with a non-Nordic ethnicity. Among children with AOD <1 year (n = 153), those born in non-Nordic countries with two non-Nordic parents (n = 6) and adopted non-Nordic children (n = 6) received their first CI on average 14.9 and 21.1 months later than Nordic children (n = 104), respectively (p = 0.006 and 0.005). Among children with AOD <1 year, those born in Nordic countries with two non-Nordic parents (n = 31) received their CI at an older age than Nordic children, but this difference was not significant after adjusting for calendar year of implantation and excluding comorbidity as a potential cause of delayed implantation. The mean age at implantation for children with AOD <1 year dropped 2.3 months/year over the study period. The mean monosyllable speech recognition score was 84.7% for Nordic children and 76.3% for children born in Norway with two non-Nordic parents (p = 0.002). The incidence of CI was significantly higher in children with a non-Nordic vs. a Nordic ethnicity, reflecting a higher incidence of profound deafness. Children born in Norway have equal access to CIs regardless of their ethnicity, but despite being born and receiving care in Norway, prelingually deaf children with non-Nordic parents are at risk of receiving CI later than Nordic children. Moreover, prelingually deaf children who arrive in Norway at an older age may be at risk for a worse prognosis after receiving a CI due to lack of auditory stimulation in early childhood, which is critical for language development and late implantation; this is a serious issue with regard to deafness among refugees. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Coco, Anne; Epp, Stephanie B.; Fallon, James B.; Xu, Jin; Millard, Rodney E.; Shepherd, Robert K.
2007-01-01
Increasing numbers of cochlear implant subjects have some level of residual hearing at the time of implantation. The present study examined whether (i) hair cells that have survived one pathological insult (aminoglycoside deafening), can survive and function following long-term cochlear implantation and electrical stimulation (ES); and (ii) chronic ES in these cochleae results in greater trophic support of spiral ganglion neurons (SGNs) compared with cochleae devoid of hair cells. Eight cats, with either partial (n=4) or severe (n=4) sensorineural hearing loss, were bilaterally implanted with scala tympani electrode arrays 2 months after deafening, and received unilateral ES using charge balanced biphasic current pulses for periods of up to 235 days. Frequency-specific compound action potentials and click-evoked auditory brainstem responses (ABRs) were recorded periodically to monitor the residual acoustic hearing. Electrically-evoked ABRs (EABRs) were recorded to confirm the stimulus levels were 3-6 dB above the EABR threshold. On completion of the ES program the cochleae were examined histologically. Partially deafened animals showed no significant increase in acoustic thresholds over the implantation period. Moreover, chronic ES of an electrode array located in the base of the cochlea did not adversely affect hair cells in the middle or apical turns. There was evidence of a small but statistically significant rescue of SGNs in the middle and apical turns of stimulated cochleae in animals with partial hearing. Chronic ES did not, however, prevent a reduction in SGN density for the severely deaf cohort, although SGNs adjacent to the stimulating electrodes did exhibit a significant increase in soma area (p<0.01). In sum, chronic ES in partial hearing animals does not adversely affect functioning residual hair cells apical to the electrode array. Moreover, while there is an increase in the soma area of SGNs close to the stimulating electrodes in severely deaf cochleae, this trophic effect does not result in increased SGN survival. PMID:17258411
Quality-of-life benefit from cochlear implantation in the elderly.
Vermeire, Katrien; Brokx, Jan P L; Wuyts, Floris L; Cochet, Ellen; Hofkens, Anouk; Van de Heyning, Paul H
2005-03-01
To compare the audiologic results of geriatric patients receiving cochlear implants with younger age groups and to evaluate the quality of life after cochlear implantation in the geriatric population by means of validated quality-of-life questionnaires. Cross-sectional study involving 89 postlingually deafened cochlear implant subjects. Tertiary referral center. A total of 89 postlingually deafened patients were included in the study, among which were 25 patients who were aged 70 years or older. All patients received a cochlear implant. Subjects were implanted with either the Laura, Nucleus 24, or Med-el Combi 40+ cochlear implant systems implementing the SPEAK, ACE, CIS, or CIS+ coding strategies. Speech recognition was determined by means of phonetically balanced monosyllabic word lists. The Hearing Handicap Inventory for Adults, the Glasgow Benefit Inventory, and the scale for the prediction of hearing disability in sensorineural hearing loss were used to quantify the quality of life. Mean audiologic performance for the three groups increased significantly after implantation (p < 0.001). Postoperative audiologic performance of the geriatric population led to useful hearing, but these scores were significantly lower than for the younger age groups (p = 0.002). However, the quality-of-life outcomes for the geriatric group were similar to those of the younger age groups (p = 0.411 for the Hearing Handicap Inventory for Adults; p = 0.886 for the Glasgow Benefit Inventory). The results of this study prove that cochlear implantation in the elderly provides improvements in quality of life and speech understanding, similar to those for younger adult cochlear implant recipients.
ERIC Educational Resources Information Center
Clark, Catherine
2010-01-01
This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…
ERIC Educational Resources Information Center
Bakar, Zaharah Abu; Brown, P. Margaret; Remine, Maria D.
2010-01-01
This study investigated the potential effects of cochlear implantation and age at implantation on maternal interactional sensitivity. Three groups of dyads were studied at two points over 1 year. The hearing aid (HA) group wore hearing aids throughout the study, the early cochlear implanted (ECI) group were implanted prior to 22 months of age, and…
Benito-González, Fernando; Benito, Jose; Sánchez, Luis Alberto Guardado; Estevez Alonso, Santiago; Muñoz Herrera, Angel; Batuecas-Caletrio, Angel
2014-09-01
The objective was to report the effectiveness of salvage treatment in soft tissue infection around cochlear implants with an absorbable gentamicin collagen sheet and a periosteum and skin rotation flaps. Three patients with cochlear implant and persistent surrounding soft tissue infection are included. All of them underwent antibiotic treatment prior to surgery without any response. In this study preoperative and postoperative audiograms were practiced. Surgical excision of infectious skin and a periosteum and skin rotation flaps were performed. The cochlear implant was refixed in the temporal bone and a gentamicin-impregnated collagen sheet was located covering the cochlear implant. headings In all patients with soft tissue infection around the cochlear implant, infection was completely resolved. It was not necessary to remove the device in any case. The use of an absorbable gentamicin-impregnated collagen sheet is not described for the management of soft tissue complications in pediatric cochlear implant patients. The local application of high concentrations of antibiotic administered by this sheet may be effective against resistant bacteria and, in conjunction with surgery, may resolve this type of complications.
International survey of cochlear implant candidacy.
Vickers, D; De Raeve, L; Graham, J
2016-04-01
The goal of this work was to determine international differences in candidacy based on audiometric and speech perception measures, and to evaluate the information in light of the funding structure and access to implants within different countries. An online questionnaire was circulated to professionals in 25 countries. There were 28 respondents, representing the candidacy practice in 17 countries. Results showed differences in the funding model between countries. Unilateral implants for both adults and children and bilateral implants for children were covered by national funding in approximately 60% of countries (30% used medical insurance, and 10% self-funding). Fewer countries provided bilateral implants routinely for adults: national funding was available in only 22% (37% used medical insurance and 41% self-funding). Main evolving candidacy areas are asymmetric losses, auditory neuropathy spectrum disorders and electro-acoustic stimulation. For countries using speech-based adult candidacy assessments, the majority (40%) used word tests, 24% used sentence tests, and 36% used a mixture of both. For countries using audiometry for candidacy (70-80% of countries), the majority used levels of 75-85 dB HL at frequencies above 1 kHz. The United Kingdom and Belgium had the most conservative audiometric criteria, and countries such as Australia, Germany, and Italy were the most lenient. Countries with a purely self-funding model had greater flexibility in candidacy requirements.
The benefits of remote microphone technology for adults with cochlear implants.
Fitzpatrick, Elizabeth M; Séguin, Christiane; Schramm, David R; Armstrong, Shelly; Chénier, Josée
2009-10-01
Cochlear implantation has become a standard practice for adults with severe to profound hearing loss who demonstrate limited benefit from hearing aids. Despite the substantial auditory benefits provided by cochlear implants, many adults experience difficulty understanding speech in noisy environments and in other challenging listening conditions such as television. Remote microphone technology may provide some benefit in these situations; however, little is known about whether these systems are effective in improving speech understanding in difficult acoustic environments for this population. This study was undertaken with adult cochlear implant recipients to assess the potential benefits of remote microphone technology. The objectives were to examine the measurable and perceived benefit of remote microphone devices during television viewing and to assess the benefits of a frequency-modulated system for speech understanding in noise. Fifteen adult unilateral cochlear implant users were fit with remote microphone devices in a clinical environment. The study used a combination of direct measurements and patient perceptions to assess speech understanding with and without remote microphone technology. The direct measures involved a within-subject repeated-measures design. Direct measures of patients' speech understanding during television viewing were collected using their cochlear implant alone and with their implant device coupled to an assistive listening device. Questionnaires were administered to document patients' perceptions of benefits during the television-listening tasks. Speech recognition tests of open-set sentences in noise with and without remote microphone technology were also administered. Participants showed improved speech understanding for television listening when using remote microphone devices coupled to their cochlear implant compared with a cochlear implant alone. This benefit was documented both when listening to news and talk show recordings. Questionnaire results also showed statistically significant differences between listening with a cochlear implant alone and listening with a remote microphone device. Participants judged that remote microphone technology provided them with better comprehension, more confidence, and greater ease of listening. Use of a frequency-modulated system coupled to a cochlear implant also showed significant improvement over a cochlear implant alone for open-set sentence recognition in +10 and +5 dB signal to noise ratios. Benefits were measured during remote microphone use in focused-listening situations in a clinical setting, for both television viewing and speech understanding in noise in the audiometric sound suite. The results suggest that adult cochlear implant users should be counseled regarding the potential for enhanced speech understanding in difficult listening environments through the use of remote microphone technology.
Francis, Howard W; Pulsifer, Margaret B; Chinnici, Jill; Nutt, Robert; Venick, Holly S; Yeagle, Jennifer D; Niparko, John K
2004-05-01
This study explored factors associated with speech recognition outcomes in postmeningitic deafness (PMD). The results of cochlear implantation may vary in children with PMD because of sequelae that extend beyond the auditory periphery. To determine which factors might be most determinative of outcome of cochlear implantation in children with PMD. Retrospective chart review. A referral center for pediatric cochlear implantation and rehabilitation. Thirty children with cochlear implants who were deafened by meningitis were matched with subjects who were deafened by other causes based on the age at diagnosis, age at cochlear implantation, age at which hearing aids were first used, and method of communication used at home or in the classroom. Speech perception performance within the first 2 years after cochlear implantation and its relationship with presurgical cognitive measures and medical history. There was no difference in the overall cognitive or postoperative speech perception performance between the children with PMD and those deafened by other causes. The presence of postmeningitic hydrocephalus, however, posed greater challenges to the rehabilitation process, as indicated by significantly smaller gains in speech perception and a predilection for behavioral problems. By comparison, cochlear scarring and incomplete electrode insertion had no impact on speech perception results. Although the results demonstrated no significant delay in cognitive or speech perception performance in the PMD group, central nervous system residua, when present, can impede the acquisition of speech perception with a cochlear implant. Central effects associated with PMD may thus impact language learning potential; cognitive and behavioral therapy should be considered in rehabilitative planning and in establishing expectations of outcome.
Banakis Hartl, Renee M; Mattingly, Jameson K; Greene, Nathaniel T; Jenkins, Herman A; Cass, Stephen P; Tollin, Daniel J
2016-10-01
A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative ABG remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative ABG. Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with previous literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable after electrode placement. Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity.
Musical ear syndrome in adult cochlear implant patients.
Low, W-K; Tham, C A; D'Souza, V-D; Teng, S-W
2013-09-01
Except for a single case report, musical ear syndrome in cochlear implantees has not been studied. We aimed to study the prevalence and nature of musical ear syndrome among adult cochlear implant patients, as well as the effect on their emotional well-being. STUDY DESIGN, PATIENTS AND INTERVENTION: A cross-sectional survey of patients aged 18 years and above who had received cochlear implants for profound hearing loss between 1997 and 2010. Of the 82 patients studied, 18 (22 per cent) were found to have experienced musical ear syndrome. Seven and 11 patients had musical ear syndrome prior to and after cochlear implantation, respectively. The character of musical ear syndrome symptoms was described as instrumental music (n = 2), singing (6) or both (10). Fourteen patients reported an adverse emotional effect, with three expressing ‘intolerance’. In this study, 22 per cent of cochlear implantees experienced musical ear syndrome. These symptoms affected patients’ emotional state, but most coped well. Musical ear syndrome can occur prior to and after cochlear implantation.
Cochlear implants and ex vivo BDNF gene therapy protect spiral ganglion neurons.
Rejali, Darius; Lee, Valerie A; Abrashkin, Karen A; Humayun, Nousheen; Swiderski, Donald L; Raphael, Yehoash
2007-06-01
Spiral ganglion neurons often degenerate in the deaf ear, compromising the function of cochlear implants. Cochlear implant function can be improved by good preservation of the spiral ganglion neurons, which are the target of electrical stimulation by the implant. Brain derived neurotrophic factor (BDNF) has previously been shown to enhance spiral ganglion survival in experimentally deafened ears. Providing enhanced levels of BDNF in human ears may be accomplished by one of several different methods. The goal of these experiments was to test a modified design of the cochlear implant electrode that includes a coating of fibroblast cells transduced by a viral vector with a BDNF gene insert. To accomplish this type of ex vivo gene transfer, we transduced guinea pig fibroblasts with an adenovirus with a BDNF gene cassette insert, and determined that these cells secreted BDNF. We then attached BDNF-secreting cells to the cochlear implant electrode via an agarose gel, and implanted the electrode in the scala tympani. We determined that the BDNF expressing electrodes were able to preserve significantly more spiral ganglion neurons in the basal turns of the cochlea after 48 days of implantation when compared to control electrodes. This protective effect decreased in the higher cochlear turns. The data demonstrate the feasibility of combining cochlear implant therapy with ex vivo gene transfer for enhancing spiral ganglion neuron survival.
ERIC Educational Resources Information Center
Ben-Itzhak, D.; Most, T.; Weisel, A.
2005-01-01
The present study examined the relationships between teachers' and communication clinicians' self-reported knowledge on cochlear implants and their expectations of CIs. The authors also explored these professionals' views regarding the child's communication mode, educational setting, and social options following cochlear implantation. The…
The Relationship between Cochlear Implants and Deaf Identity
ERIC Educational Resources Information Center
Chapman, Madeline; Dammeyer, Jesper
2017-01-01
The degree to which individuals with cochlear implants (CIs) experience communication difficulties has implications for social participation and identity development. However, few studies have examined the relationship between cochlear implantation, identity, and social participation. Using data from a Danish national survey of deaf adults, the…
Use of suprathreshold stochastic resonance in cochlear implant coding
NASA Astrophysics Data System (ADS)
Allingham, David; Stocks, Nigel G.; Morse, Robert P.
2003-05-01
In this article we discuss the possible use of a novel form of stochastic resonance, termed suprathreshold stochastic resonance (SSR), to improve signal encoding/transmission in cochlear implants. A model, based on the leaky-integrate-and-fire (LIF) neuron, has been developed from physiological data and use to model information flow in a population of cochlear nerve fibers. It is demonstrated that information flow can, in principle, be enhanced by the SSR effect. Furthermore, SSR was found to enhance information transmission for signal parameters that are commonly encountered in cochlear implants. This, therefore, gives hope that SSR may be implemented in cochlear implants to improve speech comprehension.
Won, Jong Ho; Jones, Gary L; Drennan, Ward R; Jameyson, Elyse M; Rubinstein, Jay T
2011-10-01
Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an "ideal observer," showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. © 2011 Acoustical Society of America
Ho Won, Jong; Jones, Gary L.; Drennan, Ward R.; Jameyson, Elyse M.; Rubinstein, Jay T.
2011-01-01
Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an “ideal observer,” showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. PMID:21973363
Liu, Yuying; Dong, Ruijuan; Li, Yuling; Xu, Tianqiu; Li, Yongxin; Chen, Xueqing; Gong, Shusheng
2014-12-01
To evaluate the auditory and speech abilities in children with auditory neuropathy spectrum disorder (ANSD) after cochlear implantation (CI) and determine the role of age at implantation. Ten children participated in this retrospective case series study. All children had evidence of ANSD. All subjects had no cochlear nerve deficiency on magnetic resonance imaging and had used the cochlear implants for a period of 12-84 months. We divided our children into two groups: children who underwent implantation before 24 months of age and children who underwent implantation after 24 months of age. Their auditory and speech abilities were evaluated using the following: behavioral audiometry, the Categories of Auditory Performance (CAP), the Meaningful Auditory Integration Scale (MAIS), the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS), the Standard-Chinese version of the Monosyllabic Lexical Neighborhood Test (LNT), the Multisyllabic Lexical Neighborhood Test (MLNT), the Speech Intelligibility Rating (SIR) and the Meaningful Use of Speech Scale (MUSS). All children showed progress in their auditory and language abilities. The 4-frequency average hearing level (HL) (500Hz, 1000Hz, 2000Hz and 4000Hz) of aided hearing thresholds ranged from 17.5 to 57.5dB HL. All children developed time-related auditory perception and speech skills. Scores of children with ANSD who received cochlear implants before 24 months tended to be better than those of children who received cochlear implants after 24 months. Seven children completed the Mandarin Lexical Neighborhood Test. Approximately half of the children showed improved open-set speech recognition. Cochlear implantation is helpful for children with ANSD and may be a good optional treatment for many ANSD children. In addition, children with ANSD fitted with cochlear implants before 24 months tended to acquire auditory and speech skills better than children fitted with cochlear implants after 24 months. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Lawler, Marshall; Yu, Jeffrey; Aronoff, Justin M
Although speech perception is the gold standard for measuring cochlear implant (CI) users' performance, speech perception tests often require extensive adaptation to obtain accurate results, particularly after large changes in maps. Spectral ripple tests, which measure spectral resolution, are an alternate measure that has been shown to correlate with speech perception. A modified spectral ripple test, the spectral-temporally modulated ripple test (SMRT) has recently been developed, and the objective of this study was to compare speech perception and performance on the SMRT for a heterogeneous population of unilateral CI users, bilateral CI users, and bimodal users. Twenty-five CI users (eight using unilateral CIs, nine using bilateral CIs, and eight using a CI and a hearing aid) were tested on the Arizona Biomedical Institute Sentence Test (AzBio) with a +8 dB signal to noise ratio, and on the SMRT. All participants were tested with their clinical programs. There was a significant correlation between SMRT and AzBio performance. After a practice block, an improvement of one ripple per octave for SMRT corresponded to an improvement of 12.1% for AzBio. Additionally, there was no significant difference in slope or intercept between any of the CI populations. The results indicate that performance on the SMRT correlates with speech recognition in noise when measured across unilateral, bilateral, and bimodal CI populations. These results suggest that SMRT scores are strongly associated with speech recognition in noise ability in experienced CI users. Further studies should focus on increasing both the size and diversity of the tested participants, and on determining whether the SMRT technique can be used for early predictions of long-term speech scores, or for evaluating differences among different stimulation strategies or parameter settings.
Music activities and responses of young cochlear implant recipients.
van Besouw, Rachel M; Grasmeder, Mary L; Hamilton, Mary E; Baumann, Sarah E
2011-05-01
The development of auditory receptive skills and spoken language is often delayed in children who use cochlear implants, which may affect their appreciation of and responses to music. This in turn may be interpreted as disinterest in music. A questionnaire was developed to determine whether differences in exposure and responses to music exist between young cochlear implant recipients and their normally hearing peers. The questionnaire was developed by a multidisciplinary team and distributed to parents of preschool children with normal hearing and to parents of preschool children who had been implanted at least one year prior. The cochlear implant group comprised 23 children and was gender and age matched (within ±2 months) to a group of children with normal hearing. Young cochlear implant recipients receive similar exposure to audiovisual music media, parental singing and musical instruments at home. However, the data suggest that they receive less exposure to children's music presented without visual stimuli. Parents also reported less sophisticated responses to music for this group. The findings of this study have important implications concerning the provision of age-appropriate music habilitation materials and activities for young cochlear implant recipients.
Dai, Chuanfu; Zhao, Zeqi; Zhang, Duo; Lei, Guanxiong
2018-01-01
Background The aim of this study was to explore the value of the spectral ripple discrimination test in speech recognition evaluation among a deaf (post-lingual) Mandarin-speaking population in China following cochlear implantation. Material/Methods The study included 23 Mandarin-speaking adult subjects with normal hearing (normal-hearing group) and 17 deaf adults who were former Mandarin-speakers, with cochlear implants (cochlear implantation group). The normal-hearing subjects were divided into men (n=10) and women (n=13). The spectral ripple discrimination thresholds between the groups were compared. The correlation between spectral ripple discrimination thresholds and Mandarin speech recognition rates in the cochlear implantation group were studied. Results Spectral ripple discrimination thresholds did not correlate with age (r=−0.19; p=0.22), and there was no significant difference in spectral ripple discrimination thresholds between the male and female groups (p=0.654). Spectral ripple discrimination thresholds of deaf adults with cochlear implants were significantly correlated with monosyllabic recognition rates (r=0.84; p=0.000). Conclusions In a Mandarin Chinese speaking population, spectral ripple discrimination thresholds of normal-hearing individuals were unaffected by both gender and age. Spectral ripple discrimination thresholds were correlated with Mandarin monosyllabic recognition rates of Mandarin-speaking in post-lingual deaf adults with cochlear implants. The spectral ripple discrimination test is a promising method for speech recognition evaluation in adults following cochlear implantation in China. PMID:29806954
Dai, Chuanfu; Zhao, Zeqi; Shen, Weidong; Zhang, Duo; Lei, Guanxiong; Qiao, Yuehua; Yang, Shiming
2018-05-28
BACKGROUND The aim of this study was to explore the value of the spectral ripple discrimination test in speech recognition evaluation among a deaf (post-lingual) Mandarin-speaking population in China following cochlear implantation. MATERIAL AND METHODS The study included 23 Mandarin-speaking adult subjects with normal hearing (normal-hearing group) and 17 deaf adults who were former Mandarin-speakers, with cochlear implants (cochlear implantation group). The normal-hearing subjects were divided into men (n=10) and women (n=13). The spectral ripple discrimination thresholds between the groups were compared. The correlation between spectral ripple discrimination thresholds and Mandarin speech recognition rates in the cochlear implantation group were studied. RESULTS Spectral ripple discrimination thresholds did not correlate with age (r=-0.19; p=0.22), and there was no significant difference in spectral ripple discrimination thresholds between the male and female groups (p=0.654). Spectral ripple discrimination thresholds of deaf adults with cochlear implants were significantly correlated with monosyllabic recognition rates (r=0.84; p=0.000). CONCLUSIONS In a Mandarin Chinese speaking population, spectral ripple discrimination thresholds of normal-hearing individuals were unaffected by both gender and age. Spectral ripple discrimination thresholds were correlated with Mandarin monosyllabic recognition rates of Mandarin-speaking in post-lingual deaf adults with cochlear implants. The spectral ripple discrimination test is a promising method for speech recognition evaluation in adults following cochlear implantation in China.
The Modified Rambo Transcanal Approach for Cochlear Implantation in CHARGE Syndrome.
Wick, Cameron C; Moore, Amy M; Killeen, Daniel E; Isaacson, Brandon
2017-10-01
CHARGE syndrome is associated with a variety of temporal bone anomalies and deafness. The lack of surgical landmarks and facial nerve irregularities make cochlear implantation in this population a challenging endeavor. This study aims to describe a safe and efficacious transcanal approach for cochlear implantation that obviates the need to perform a mastoidectomy and facial recess. Three children with profound hearing loss secondary to CHARGE syndrome. Transcanal cochlear implantation with closure of the ear canal via a modified Rambo meatoplasty. Retrospective chart review of temporal bone anomalies associated with CHARGE syndrome, technical nuances of this transcanal approach, and cochlear implant outcomes. The mean patient age was 2.5 years (range 1.5-3.8 yr). Two were male and two were left ears. All patients had a hypoplastic mastoid, semicircular canal aplasia, and had some degree of cochlear dysplasia. A full cochlear implant insertion was achieved in all cases, even in the presence of grossly abnormal middle ear and facial nerve anatomy. There were no intraoperative or postoperative complications. The mean follow-up was 12.4 months (range, 3.9-25.2 mo). All three patients use their device daily. Their guardians report improved vocalization and environmental awareness. The modified Rambo transcanal approach provides a safe corridor for cochlear implantation in patients with CHARGE syndrome. This approach minimizes the anatomical variations associated with the syndrome and may reduce the risk of electrode extrusion. Implant outcomes in this patient population remain highly variable based on the patient's global cognitive capacity.
Bush, Matthew L.; Burton, Mary; Loan, Ashley; Shinn, Jennifer B.
2013-01-01
Objective The purpose of this study was to examine the timing of early intervention diagnostic and therapeutic services in cochlear implant recipients from rural and urban areas. Study design Retrospective case series review Setting Tertiary referral center Patients Cochlear implant recipients from a single comprehensive hearing institute born with severe congenital sensorineural hearing loss were examined. Timing of diagnostic and therapeutic services was examined. Intervention(s) Diagnosis, amplification, and eventual cochlear implantation for all patients in the study Main outcome measure(s) Time points of definitive diagnosis, amplification, and cochlear implantation for children from urban and rural regions were examined. Correlation analysis of distance to testing center and timing of services was also assessed. Results 40 children born with congenital hearing loss were included in the study and were diagnosed at a median age of 13 weeks after birth. Children from rural regions obtained amplification at a median age of 47.7 weeks after birth, while urban children were amplified at 26 weeks after birth. Cochlear implantation was performed at a median age of 182 weeks after birth in those from rural areas and at 104 weeks after birth in urban-dwelling patients. A linear relationship was identified between distance to the implant center and timing of hearing aid amplification (r=0.5, p=0.033) and cochlear implantation (r=0.5, p=0.016). Conclusions Children residing outside of metro areas may be at higher risk of delayed rehabilitative services and cochlear implantation than those residing in urban areas that may be closer in proximity to tertiary care centers. PMID:24136305
Goh, Terence; Bird, Philip; Pearson, John; Mustard, Jill
2016-01-01
The purpose of this study is to observe the education and vocational achievements and social participation of cochlear implant recipients as they graduate from a paediatric cochlear implant programme and identify any significant associations that might exist. This study identified 56 patients from the Southern Cochlear Implant Programme (SCIP) who received cochlear implants before the age of 19 (paediatric) and are now over the age of 19 (adult). A questionnaire investigated their education, employment, and identity with the hearing and deaf communities. Also included were the satisfaction with life scale and Hearing Participation Scale (HPS). Subjects ranged in age from 19 to 32. Twenty-six patients responded to the questionnaire, including one non-user. Twenty identified strongly or very strongly with the hearing community. There was weak evidence of a linear association between strong identity with the hearing community and a higher HPS score. No other statistically significant associations were detected. Interestingly, 12 out of 26 participants found employment through family. Positive outcome trends in education and employment were seen in this study although no statistical significance was achieved. There is a strong bias for those who use their cochlear implants regularly, and there are no data available for those who do not use their cochlear implants for comparison as only one non-user completed the survey, despite efforts to include this group. This study shows that there is perceived benefit in implantation for patients who use it regularly but further research is needed with a more diverse group of cochlear implant recipients.
Huang, B Y; Roche, J P; Buchman, C A; Castillo, M
2010-11-01
Cranial abnormalities, including CND, are common in children with ANSD. The purpose of this study was to assess whether CND is associated with brain or inner ear abnormalities in a cohort of children with ANSD. Two neuroradiologists retrospectively reviewed cranial MR imaging examinations in 103 children with ANSD. Brain, cochlear nerve, and temporal bone abnormalities were described and tabulated. Findings were stratified on the basis of the presence and laterality of CND, and differences in the presence of associated inner ear or intracranial abnormalities were assessed by using 2-tailed Fisher exact tests. CND was identified in 33.0% of children and 26.9% of ears with ANSD. Significantly more patients with bilateral CND had intracranial abnormalities than those with unilateral CND (60.0% versus 15.8%; P = .012). Forty percent of patients with bilateral CND, 0% of patients with unilateral CND, and 10.1% of those without CND demonstrated hindbrain malformations. Patients with bilateral CND were more likely to demonstrate hindbrain malformations than patients with normal nerves (P = .01) or unilateral CND (P = .004). Labyrinthine abnormalities were significantly more common in patients with bilateral CND than in those without CND (P ≤ .001). Cochlear anomalies were more common in patients with bilateral versus unilateral CND (P = .01). IAC and cochlear aperture stenosis were more common in those with unilateral and bilateral CND than those without CND (both P < .001). Cochlear and hindbrain abnormalities are significantly more common among patients with ANSD with bilateral CND compared with those with at least 1 intact cochlear nerve.
Deafblind People's Experiences of Cochlear Implantation
ERIC Educational Resources Information Center
Soper, Janet
2006-01-01
Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…
Melodic contour identification by cochlear implant listeners.
Galvin, John J; Fu, Qian-Jie; Nogaki, Geraldine
2007-06-01
While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task could be used to quantify cochlear implant users' ability to recognize musical melodies and whether MCI performance could be improved with moderate auditory training. The present study also compared MCI performance with familiar melody identification (FMI) performance, with and without MCI training. For the MCI task, test stimuli were melodic contours composed of 5 notes of equal duration whose frequencies corresponded to musical intervals. The interval between successive notes in each contour was varied between 1 and 5 semitones; the "root note" of the contours was also varied (A3, A4, and A5). Nine distinct musical patterns were generated for each interval and root note condition, resulting in a total of 135 musical contours. The identification of these melodic contours was measured in 11 cochlear implant users. FMI was also evaluated in the same subjects; recognition of 12 familiar melodies was tested with and without rhythm cues. MCI was also trained in 6 subjects, using custom software and melodic contours presented in a different frequency range from that used for testing. Results showed that MCI recognition performance was highly variable among cochlear implant users, ranging from 14% to 91% correct. For most subjects, MCI performance improved as the number of semitones between successive notes was increased; performance was slightly lower for the A3 root note condition. Mean FMI performance was 58% correct when rhythm cues were preserved and 29% correct when rhythm cues were removed. Statistical analyses revealed no significant correlation between MCI performance and FMI performance (with or without rhythmic cues). However, MCI performance was significantly correlated with vowel recognition performance; FMI performance was not correlated with cochlear implant subjects' phoneme recognition performance. Preliminary results also showed that the MCI training improved all subjects' MCI performance; the improved MCI performance also generalized to improved FMI performance. Preliminary data indicate that the closed-set MCI task is a viable approach toward quantifying an important component of cochlear implant users' music perception. The improvement in MCI performance and generalization to FMI performance with training suggests that MCI training may be useful for improving cochlear implant users' music perception and appreciation; such training may be necessary to properly evaluate patient performance, as acute measures may underestimate the amount of musical information transmitted by the cochlear implant device and received by cochlear implant listeners.
Educational Interpreters: Meeting the Communication Needs of Children with Cochlear Implants
ERIC Educational Resources Information Center
Melton, Julie; Higbee, Renee
2013-01-01
Since the early 1990s, when the U.S. Food and Drug Administration approved cochlear implants for deaf and hard of hearing children, the number of children who have cochlear implants has increased in mainstream settings. Recent research suggests that these students, like their deaf and hard of hearing peers without implants who use sign language,…
Cochlear implants and spoken language processing abilities: review and assessment of the literature.
Peterson, Nathaniel R; Pisoni, David B; Miyamoto, Richard T
2010-01-01
Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading). However, there is wide variation in individual outcomes following cochlear implantation, and some CI recipients never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. The variables most strongly associated with language outcomes are age at implantation and mode of communication in rehabilitation. Thus, some of the more important factors determining success of cochlear implantation are broadly related to neural plasticity that appears to be transiently present in deaf individuals. In this article we review the expected outcomes of cochlear implantation, potential predictors of those outcomes, the basic science regarding critical and sensitive periods, and several new research directions in the field of cochlear implantation.
Music training improves pitch perception in prelingually deafened children with cochlear implants.
Chen, Joshua Kuang-Chao; Chuang, Ann Yi Chiun; McMahon, Catherine; Hsieh, Jen-Chuen; Tung, Tao-Hsin; Li, Lieber Po-Hung
2010-04-01
The comparatively poor music appreciation in patients with cochlear implants might be ascribed to an inadequate exposure to music; however, the effect of training on music perception in prelingually deafened children with cochlear implants remains unknown. This study aimed to investigate whether previous musical education improves pitch perception ability in these children. Twenty-seven children with congenital/prelingual deafness of profound degree were studied. Test stimuli consisted of 2 sequential piano tones, ranging from C (256 Hz) to B (495 Hz). Children were asked to identify the pitch relationship between the 2 tones (same, higher, or lower). Effects of musical training duration, pitch-interval size, current age, age of implantation, gender, and type of cochlear implant on accuracy of pitch perception were evaluated. The duration of musical training positively correlated with the correct rate of pitch perception. Pitch perception performance was better in children who had a cochlear implant and were older than 6 years than in those who were aged < or =6 years (ie, preschool). Effect of pitch-interval size was insignificant on pitch perception, and there was no correlation between pitch perception and the age of implantation, gender, or type of cochlear implant. Musical training seems to improve pitch perception ability in prelingually deafened children with a cochlear implant. Auditory plasticity might play an important role in such enhancement. This suggests that incorporation of a structured training program on music perception early in life and as part of the postoperative rehabilitation program for prelingually deafened children with cochlear implants would be beneficial. A longitudinal study is needed to show whether improvement of music performance in these children is measurable by use of auditory evoked potentials.
Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.
Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O
2013-06-01
To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is <90°, there is no demagnetisation; if the bi/b0 angle is >90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.
Negotiating Reassurance: Parents' Narratives on Follow-Up after Cochlear Implantation
ERIC Educational Resources Information Center
Bruin, Marieke; Ohna, Stein Erik
2015-01-01
This study presents an analysis of parental experiences on follow-up after cochlear implantation. Data were constructed in semi-structured, individual interviews with the parents of 14 children who use cochlear implants. Drawing on narrative analysis, the study explores parental responses to insecurity concerning children's learning and…
Challenges in Optimizing Oral Communication in Children with Cochlear Implants.
ERIC Educational Resources Information Center
Ertmer, David J.
2002-01-01
This article introduces a forum that provides information for assisting speech-language pathologists and audiologists in fulfilling their professional responsibilities in a variety of settings to children with hearing impairments who have cochlear implants. A preview of the following articles on services for children with cochlear implants is…
Voice emotion perception and production in cochlear implant users.
Jiam, N T; Caldwell, M; Deroche, M L; Chatterjee, M; Limb, C J
2017-09-01
Voice emotion is a fundamental component of human social interaction and social development. Unfortunately, cochlear implant users are often forced to interface with highly degraded prosodic cues as a result of device constraints in extraction, processing, and transmission. As such, individuals with cochlear implants frequently demonstrate significant difficulty in recognizing voice emotions in comparison to their normal hearing counterparts. Cochlear implant-mediated perception and production of voice emotion is an important but relatively understudied area of research. However, a rich understanding of the voice emotion auditory processing offers opportunities to improve upon CI biomedical design and to develop training programs benefiting CI performance. In this review, we will address the issues, current literature, and future directions for improved voice emotion processing in cochlear implant users. Copyright © 2017 Elsevier B.V. All rights reserved.
Meyer, Ted A; Frisch, Stefan A; Pisoni, David B; Miyamoto, Richard T; Svirsky, Mario A
2003-07-01
Do cochlear implants provide enough information to allow adult cochlear implant users to understand words in ways that are similar to listeners with acoustic hearing? Can we use a computational model to gain insight into the underlying mechanisms used by cochlear implant users to recognize spoken words? The Neighborhood Activation Model has been shown to be a reasonable model of word recognition for listeners with normal hearing. The Neighborhood Activation Model assumes that words are recognized in relation to other similar-sounding words in a listener's lexicon. The probability of correctly identifying a word is based on the phoneme perception probabilities from a listener's closed-set consonant and vowel confusion matrices modified by the relative frequency of occurrence of the target word compared with similar-sounding words (neighbors). Common words with few similar-sounding neighbors are more likely to be selected as responses than less common words with many similar-sounding neighbors. Recent studies have shown that several of the assumptions of the Neighborhood Activation Model also hold true for cochlear implant users. Closed-set consonant and vowel confusion matrices were obtained from 26 postlingually deafened adults who use cochlear implants. Confusion matrices were used to represent input errors to the Neighborhood Activation Model. Responses to the different stimuli were then generated by the Neighborhood Activation Model after incorporating the frequency of occurrence counts of the stimuli and their neighbors. Model outputs were compared with obtained performance measures on the Consonant-Vowel Nucleus-Consonant word test. Information transmission analysis was used to assess whether the Neighborhood Activation Model was able to successfully generate and predict word and individual phoneme recognition by cochlear implant users. The Neighborhood Activation Model predicted Consonant-Vowel Nucleus-Consonant test words at levels similar to those correctly identified by the cochlear implant users. The Neighborhood Activation Model also predicted phoneme feature information well. The results obtained suggest that the Neighborhood Activation Model provides a reasonable explanation of word recognition by postlingually deafened adults after cochlear implantation. It appears that multichannel cochlear implants give cochlear implant users access to their mental lexicons in a manner that is similar to listeners with acoustic hearing. The lexical properties of the test stimuli used to assess performance are important to spoken-word recognition and should be included in further models of the word recognition process.
Banakis Hartl, Renee M.; Mattingly, Jameson K.; Greene, Nathaniel T.; Jenkins, Herman A.; Cass, Stephen P.; Tollin, Daniel J.
2016-01-01
Hypothesis A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Background Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative air-bone gap remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative air-bone gap. Methods Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Results Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with prior literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable following electrode placement. Conclusion Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity. PMID:27579835
Temporal stability of music perception and appraisal scores of adult cochlear implant recipients.
Gfeller, Kate; Jiang, Dingfeng; Oleson, Jacob J; Driscoll, Virginia; Knutson, John F
2010-01-01
An extensive body of literature indicates that cochlear implants (CIs) are effective in supporting speech perception of persons with severe to profound hearing losses who do not benefit to any great extent from conventional hearing aids. Adult CI recipients tend to show significant improvement in speech perception within 3 mo following implantation as a result of mere experience. Furthermore, CI recipients continue to show modest improvement as long as 5yr postimplantation. In contrast, data taken from single testing protocols of music perception and appraisal indicate that CIs are less than ideal in transmitting important structural features of music, such as pitch, melody, and timbre. However, there is presently little information documenting changes in music perception or appraisal over extended time as a result of mere experience. This study examined two basic questions: (1) Do adult CI recipients show significant improvement in perceptual acuity or appraisal of specific music listening tasks when tested in two consecutive years? (2) If there are tasks for which CI recipients show significant improvement with time, are there particular demographic variables that predict those CI recipients most likely to show improvement with extended CI use? A longitudinal cohort study. Implant recipients return annually for visits to the clinic. The study included 209 adult cochlear implant recipients with at least 9 mo implant experience before their first year measurement. Outcomes were measured on the patient's annual visit in two consecutive years. Paired t-tests were used to test for significant improvement from one year to the next. Those variables demonstrating significant improvement were subjected to regression analyses performed to detect the demographic variables useful in predicting said improvement. There were no significant differences in music perception outcomes as a function of type of device or processing strategy used. Only familiar melody recognition (FMR) and recognition of melody excerpts with lyrics (MERT-L) showed significant improvement from one year to the next. After controlling for the baseline value, hearing aid use, months of use, music listening habits after implantation, and formal musical training in elementary school were significant predictors of FMR improvement. Bilateral CI use, formal musical training in high school and beyond, and a measure of sequential cognitive processing were significant predictors of MERT-L improvement. These adult CI recipients as a result of mere experience demonstrated fairly consistent music perception and appraisal on measures gathered in two consecutive years. Gains made tend to be modest, and can be associated with characteristics such as use of hearing aids, listening experiences, or bilateral use (in the case of lyrics). These results have implications for counseling of CI recipients with regard to realistic expectations and strategies for enhancing music perception and enjoyment.
Prevention and management of cochlear implant infections.
Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D
2011-11-01
Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.
Di Nardo, W; Cattani, P; Lopizzo, T; Cantore, I; Marchese, M R; Marchetti, S; Scorpecci, A; Giannantonio, S; Parrilla, C; Cianfrone, F; Fadda, G; Paludetti, G
2009-01-01
The cause of about 30% of bilateral sensorineural hearing loss (SNHL) is still unknown. A viral etiology is among the most frequently proposed ones and the supposed diagnosis is only based upon few clinical and laboratory data. The detection of viral presence within a damaged compartment may represent a way to supply interesting data for confirmation of viral etiology and to explain pathogenic mechanisms. The aim of our study was to identify the possible presence of pathogenic viruses in the inner ear extracellular compartment in patients with bilateral severe sensorineural deafness of unknown etiology who underwent cochlear implant surgery. 4 patients, aged from 2 to 7 years and affected by SNHL underwent cochlear implantation surgery and, at the same time, endolabyrinthine fluid sampling. The samples were subsequently sent for viral nucleic acid extraction and polymerase chain reaction (PCR) treatment: multiplex PCR and realtime-PCR were used. In each endolabyrinthine fluid sample, cytomegalovirus (CMV), Epstein-Barr virus (EBV), varicella-zoster virus (VZV), herpes simplex virus type 1 and 2 (HSV-1, HSV-2) and enterovirus genomes were searched for. One patient was positive for intracochlear CMV, as confirmed by another base-pair segment PCR. EBV, VZV, HSV and enterovirus were detected in none of the 4 patients. Our finding of CMV genome within the cochlea of a deaf patient without any evidence of acute and prenatal CMV infection suggests its possible role in postnatal inner ear injury through reactivation of latent virus within the cochlea. This hypothesis could also be considered valid for some patients with anti-CMV-IgG-positive serology and absence of endolabyrinthine viral genome since viruses can be in an inactive state at the time of fluid collection. PCR has proved to be a very useful tool in order to investigate infectious causes of deafness even for more than one virus type at a time and in a limited quantity of sample, such as the small volume of endolabyrinthine liquid collected from children during cochlear implant surgery. Copyright (C) 2009 S. Karger AG, Basel.
Távora-Vieira, Dayse; Marino, Roberta; Acharya, Aanand; Rajan, Gunesh P
2015-03-01
This study aimed to determine the impact of cochlear implantation on speech understanding in noise, subjective perception of hearing, and tinnitus perception of adult patients with unilateral severe to profound hearing loss and to investigate whether duration of deafness and age at implantation would influence the outcomes. In addition, this article describes the auditory training protocol used for unilaterally deaf patients. This is a prospective study of subjects undergoing cochlear implantation for unilateral deafness with or without associated tinnitus. Speech perception in noise was tested using the Bamford-Kowal-Bench speech-in-noise test presented at 65 dB SPL. The Speech, Spatial, and Qualities of Hearing Scale and the Abbreviated Profile of Hearing Aid Benefit were used to evaluate the subjective perception of hearing with a cochlear implant and quality of life. Tinnitus disturbance was measured using the Tinnitus Reaction Questionnaire. Data were collected before cochlear implantation and 3, 6, 12, and 24 months after implantation. Twenty-eight postlingual unilaterally deaf adults with or without tinnitus were implanted. There was a significant improvement in speech perception in noise across time in all spatial configurations. There was an overall significant improvement on the subjective perception of hearing and quality of life. Tinnitus disturbance reduced significantly across time. Age at implantation and duration of deafness did not influence the outcomes significantly. Cochlear implantation provided significant improvement in speech understanding in challenging situations, subjective perception of hearing performance, and quality of life. Cochlear implantation also resulted in reduced tinnitus disturbance. Age at implantation and duration of deafness did not seem to influence the outcomes.
Sensory integration functions of children with cochlear implants.
Koester, AnjaLi Carrasco; Mailloux, Zoe; Coleman, Gina Geppert; Mori, Annie Baltazar; Paul, Steven M; Blanche, Erna; Muhs, Jill A; Lim, Deborah; Cermak, Sharon A
2014-01-01
OBJECTIVE. We investigated sensory integration (SI) function in children with cochlear implants (CIs). METHOD. We analyzed deidentified records from 49 children ages 7 mo to 83 mo with CIs. Records included Sensory Integration and Praxis Tests (SIPT), Sensory Processing Measure (SPM), Sensory Profile (SP), Developmental Profile 3 (DP-3), and Peabody Developmental Motor Scales (PDMS), with scores depending on participants' ages. We compared scores with normative population mean scores and with previously identified patterns of SI dysfunction. RESULTS. One-sample t tests revealed significant differences between children with CIs and the normative population on the majority of the SIPT items associated with the vestibular and proprioceptive bilateral integration and sequencing (VPBIS) pattern. Available scores for children with CIs on the SPM, SP, DP-3, and PDMS indicated generally typical ratings. CONCLUSION. SIPT scores in a sample of children with CIs reflected the VPBIS pattern of SI dysfunction, demonstrating the need for further examination of SI functions in children with CIs during occupational therapy assessment and intervention planning. Copyright © 2014 by the American Occupational Therapy Association, Inc.
Most, Tova; Gaon-Sivan, Gal; Shpak, Talma; Luntz, Michal
2012-01-01
Binaural hearing in cochlear implant (CI) users can be achieved either by bilateral implantation or bimodally with a contralateral hearing aid (HA). Binaural-bimodal hearing has the advantage of complementing the high-frequency electric information from the CI by low-frequency acoustic information from the HA. We examined the contribution of a contralateral HA in 25 adult implantees to their perception of fundamental frequency-cued speech characteristics (initial consonant voicing, intonation, and emotions). Testing with CI alone, HA alone, and bimodal hearing showed that all three characteristics were best perceived under the bimodal condition. Significant differences were recorded between bimodal and HA conditions in the initial voicing test, between bimodal and CI conditions in the intonation test, and between both bimodal and CI conditions and between bimodal and HA conditions in the emotion-in-speech test. These findings confirmed that such binaural-bimodal hearing enhances perception of these speech characteristics and suggest that implantees with residual hearing in the contralateral ear may benefit from a HA in that ear.
Hutter, E; Argstatter, H; Grapp, M; Plinkert, P K
2015-09-01
Although cochlear implant (CI) users achieve good speech comprehension, they experience difficulty perceiving music and prosody in speech. As the provision of music training in rehabilitation is limited, a novel concept of music therapy for rehabilitation of adult CI users was developed and evaluated in this pilot study. Twelve unilaterally implanted, postlingually deafened CI users attended ten sessions of individualized and standardized training. The training started about 6 weeks after the initial activation of the speech processor. Before and after therapy, psychological and musical tests were applied in order to evaluate the effects of music therapy. CI users completed the musical tests in two conditions: bilateral (CI + contralateral, unimplanted ear) and unilateral (CI only). After therapy, improvements were observed in the subjective sound quality (Hearing Implant Sound Quality Index) and the global score on the self-concept questionnaire (Multidimensional Self-Concept Scales) as well as in the musical subtests for melody recognition and for timbre identification in the unilateral condition. Discussion Preliminary results suggest improvements in subjective hearing and music perception, with an additional increase in global self-concept and enhanced daily listening capacities. The novel concept of individualized music therapy seems to provide an effective treatment option in the rehabilitation of adult CI users. Further investigations are necessary to evaluate effects in the area of prosody perception and to separate therapy effects from general learning effects in CI rehabilitation.
Systemic immunity influences hearing preservation in cochlear implantation.
Souter, Melanie; Eastwood, Hayden; Marovic, Paul; Kel, Gordana; Wongprasartsuk, Sarin; Ryan, Allen F; O'Leary, Stephen John
2012-06-01
To determine whether a systemic immune response influences hearing thresholds and tissue response after cochlear implantation of hearing guinea pigs. Guinea pigs were inoculated with sterile antigen (Keyhole limpet hemocyanin) 3 weeks before cochlear implantation. Pure-tone auditory brainstem response thresholds were performed before implantation and 1 and 4 weeks later. Dexamethasone phosphate 20% was adsorbed onto a hyaluronic acid carboxymethylcellulose sponge and was applied to the round window for 30 minutes before electrode insertion. Normal saline was used for controls. Cochlear histology was performed at 4 weeks after implantation to assess the tissue response to implantation. To control for the effect of keyhole limpet hemocyanin priming, a group of unprimed animals underwent cochlear implantation with a saline-soaked pledget applied to the round window. Keyhole limpet hemocyanin priming had no significant detrimental effect on thresholds without implantation. Thresholds were elevated after implantation across all frequencies tested (2-32 kHz) in primed animals but only at higher frequencies (4-32 kHz) in unprimed controls. In primed animals, dexamethasone treatment significantly reduced threshold shifts at 2 and 8 kHz. Keyhole limpet hemocyanin led to the more frequent observation of lymphocytes in the tissue response to the implant. Systemic immune activation at the time of cochlear implantation broadened the range of frequencies experiencing elevated thresholds after implantation. Local dexamethasone provides partial protection against this hearing loss, but the degree and extent of protection are less compared to previous studies with unprimed animals.
Long latency auditory evoked potentials in children with cochlear implants: systematic review.
Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de
2013-11-25
The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.
ERIC Educational Resources Information Center
Nicholas, Johanna Grant; Geers, Ann E.
2007-01-01
Purpose: The authors examined the benefits of younger cochlear implantation, longer cochlear implant use, and greater pre-implant aided hearing to spoken language at 3.5 and 4.5 years of age. Method: Language samples were obtained at ages 3.5 and 4.5 years from 76 children who received an implant by their 3rd birthday. Hierarchical linear modeling…
Cochlear implantation in autistic children with profound sensorineural hearing loss.
Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz
2016-11-19
Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Realization of Complex Onsets by Pediatric Users of Cochlear Implants
ERIC Educational Resources Information Center
Chin, Steven B.
2006-01-01
This study examined variations in English complex onset realizations by children who use cochlear implants. Data consisted of 227 productions of two-segment onset clusters from 12 children. In general, onset cluster realizations of children with cochlear implants did not differ markedly from those reported for children with normal hearing: null…
ERIC Educational Resources Information Center
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah
2012-01-01
Purpose: To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and postimplant language development and executive function. Method: Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (Family Environment Scale-Fourth…
Taxonomic Knowledge of Children with and without Cochlear Implants
ERIC Educational Resources Information Center
Lund, Emily; Dinsmoor, Jessica
2016-01-01
Purpose: The purpose of this study was to compare the taxonomic vocabulary knowledge and organization of children with cochlear implants to (a) children with normal hearing matched for age, and (b) children matched for vocabulary development. Method: Ten children with cochlear implants, 10 age-matched children with normal hearing, and 10…
Children with Cochlear Implants in Australia: Educational Settings, Supports, and Outcomes
ERIC Educational Resources Information Center
Punch, Renee; Hyde, Merv
2010-01-01
This Australian study examined the communication, academic, and social outcomes of pediatric cochlear implantation from the perspectives of teachers working with children with cochlear implants. The children were aged from 1 to 18 years and attended a range of educational settings in early intervention, primary, and secondary schooling. One…
Cochlear Implants in Children with Hearing Loss: Maternal Expectations and Impact on the Family
ERIC Educational Resources Information Center
Zaidman-Zait, Anat; Most, Tova
2005-01-01
To facilitate evaluations of cochlear implant candidates and to promote (re)habilitation efficacy and collaboration with families, this study examined the expectations of 35 mothers with typical hearing and their beliefs and difficulties related to their child's hearing loss and current or future cochlear implantation. Questionnaires measured…
ERIC Educational Resources Information Center
Geers, Ann E.; Nicholas, Johanna; Tobey, Emily; Davidson, Lisa
2016-01-01
Purpose: The purpose of the present investigation is to differentiate children using cochlear implants (CIs) who did or did not achieve age-appropriate language scores by mid-elementary grades and to identify risk factors for persistent language delay following early cochlear implantation. Materials and Method: Children receiving unilateral CIs at…
Verbal Working Memory in Children with Cochlear Implants
ERIC Educational Resources Information Center
Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.
2017-01-01
Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…
Emotion Understanding in Deaf Children with a Cochlear Implant
ERIC Educational Resources Information Center
Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.
2013-01-01
It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…
Evaluating the Feasibility of Using Remote Technology for Cochlear Implants
ERIC Educational Resources Information Center
Goehring, Jenny L.; Hughes, Michelle L.; Baudhuin, Jacquelyn L.
2012-01-01
The use of remote technology to provide cochlear implant services has gained popularity in recent years. This article contains a review of research evaluating the feasibility of remote service delivery for recipients of cochlear implants. To date, published studies have determined that speech-processor programming levels and other objective tests…
Amraei, K; Amirsalari, S; Ajalloueyan, M
2017-01-01
Hearing impairment is a common type of sensory loss in children. Studies indicate that children with hearing impairment are deficient in social, cognitive and communication skills. This study compared the intelligence quotients of first- and second-generation deaf children with cochlear implants. This research is causal-comparative. All 15 deaf children investigated had deaf parents and were selected from Baqiyatallah Cochlear Implant Center. The 15 children with cochlear implants were paired with similar children with hearing parents using purposive sampling. The findings show that the Hotelling trace of multivariate analysis of variance (F = 6.78, p < 0.01, η P 2 = 0.73) was significant. The tests of between-subjects effects for second-generation children was significantly higher than for first-generation children for all intelligence scales except knowledge. It can be assumed that second-generation children joined their family in the use of sign language as the primary experience before a cochlear implant. The use of sign language before cochlear implants is recommended. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.
Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre
2017-09-01
It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.
Blanks, Deidra A.; Buss, Emily; Grose, John H.; Fitzpatrick, Douglas C.; Hall, Joseph W.
2009-01-01
Objectives The present study investigated interaural time discrimination for binaurally mismatched carrier frequencies in listeners with normal hearing. One goal of the investigation was to gain insights into binaural hearing in patients with bilateral cochlear implants, where the coding of interaural time differences may be limited by mismatches in the neural populations receiving stimulation on each side. Design Temporal envelopes were manipulated to present low frequency timing cues to high frequency auditory channels. Carrier frequencies near 4 kHz were amplitude modulated at 128 Hz via multiplication with a half-wave rectified sinusoid, and that modulation was either in-phase across ears or delayed to one ear. Detection thresholds for non-zero interaural time differences were measured for a range of stimulus levels and a range of carrier frequency mismatches. Data were also collected under conditions designed to limit cues based on stimulus spectral spread, including masking and truncation of sidebands associated with modulation. Results Listeners with normal hearing can detect interaural time differences in the face of substantial mismatches in carrier frequency across ears. Conclusions The processing of interaural time differences in listeners with normal hearing is likely based on spread of excitation into binaurally matched auditory channels. Sensitivity to interaural time differences in listeners with cochlear implants may depend upon spread of current that results in the stimulation of neural populations that share common tonotopic space bilaterally. PMID:18596646
Chilosi, A M; Scusa, M F; Comparini, A; Genovese, E; Forli, F; Berrettini, S; Cipriani, P
2012-04-01
Sensorineural hearing loss (SNHL) is complicated by additional disabilities in about 30% of cases, but the epidemiology of associated disorders, in terms of type, frequency and aetiology is still not clearly defined. Additional disabilities in a deaf child have important consequences in assessing and choosing a therapeutic treatment, in particular when considering cochlear implantation (CI) or hearing aids (HA). The aim of this paper was to evaluate frequency, type and severity of additional neurodevelopmental disabilities in children with profound bilateral sensorineural hearing loss and to investigate the relationship between disability and the etiology of deafness. Eighty children with profound bilateral sensorineural hearing loss (mean age 5.4 years) were investigated by means of a diagnostic protocol including clinical, neurodevelopmental, and audiological procedures together with genetic and neurometabolic tests and neuroradiological investigation by brain MRI. Fifty-five percent of the sample exhibited one or more disabilities in addition to deafness, with cognitive, behavioural-emotional and motor disorders being the most frequent. The risk of additional disabilities varied according to aetiology, with a higher incidence in hereditary syndromic deafness, in cases due to pre-perinatal pathology (in comparison to unknown and hereditary non syndromic forms) and in the presence of major brain abnormalities at MRI. Our results suggest that the aetiology of deafness may be a significant risk indicator for the presence of neuropsychiatric disorders. A multidimensional evaluation, including aetiological, neurodevelopmental and MRI investigation is needed for formulating prognosis and for planning therapeutic intervention, especially in those children candidated to cochlear implant.
A partial hearing animal model for chronic electro-acoustic stimulation
NASA Astrophysics Data System (ADS)
Irving, S.; Wise, A. K.; Millard, R. E.; Shepherd, R. K.; Fallon, J. B.
2014-08-01
Objective. Cochlear implants (CIs) have provided some auditory function to hundreds of thousands of people around the world. Although traditionally carried out only in profoundly deaf patients, the eligibility criteria for implantation have recently been relaxed to include many partially-deaf patients with useful levels of hearing. These patients receive both electrical stimulation from their implant and acoustic stimulation via their residual hearing (electro-acoustic stimulation; EAS) and perform very well. It is unclear how EAS improves speech perception over electrical stimulation alone, and little evidence exists about the nature of the interactions between electric and acoustic stimuli. Furthermore, clinical results suggest that some patients that undergo cochlear implantation lose some, if not all, of their residual hearing, reducing the advantages of EAS over electrical stimulation alone. A reliable animal model with clinically-relevant partial deafness combined with clinical CIs is important to enable these issues to be studied. This paper outlines such a model that has been successfully used in our laboratory. Approach. This paper outlines a battery of techniques used in our laboratory to generate, validate and examine an animal model of partial deafness and chronic CI use. Main results. Ototoxic deafening produced bilaterally symmetrical hearing thresholds in neonatal and adult animals. Electrical activation of the auditory system was confirmed, and all animals were chronically stimulated via adapted clinical CIs. Acoustic compound action potentials (CAPs) were obtained from partially-hearing cochleae, using the CI amplifier. Immunohistochemical analysis allows the effects of deafness and electrical stimulation on cell survival to be studied. Significance. This animal model has applications in EAS research, including investigating the functional interactions between electric and acoustic stimulation, and the development of techniques to maintain residual hearing following cochlear implantation. The ability to record CAPs via the CI has clinical direct relevance for obtaining objective measures of residual hearing.
Tian, Yanjing; Zhou, Huifang; Zhang, Jing; Yang, Dong; Xu, Yi; Guo, Yuxi
2012-10-01
To compare the effect of rehabilitation of prelingual deaf children who used a cochlear implant (CI) in one ear and a hearing aids in the opposite ear while the hearing level of the opposite ears are different. Hearing ability, language ability and learning ability was included in the content. The aim of this research is to investigate better style of rehabilitation, and to offer the best help to the prelingual deaf children. Accord ing to the hearing level of the ear opposite to the one wearing a cochlear implant and whether the opposite ear wear a hearing aid or not, 30 prelingual deaf children were divided into three groups, including cochlear implant with opposite severe hearing loss and hearing aid ear (CI+SHA), cochlear implant with opposite profound hearing loss and hearing aid ear (CI+PHA), cochlear implant only (CI). The effect of rehabilitation was assessed in six different times (3,6,9,12,15 and 18 months after the cochlear implants and hearing aids began to work). The longer time the rehabilitation spends, the better the hearing ability,language ability and the learning ability were. The hearing ability of CI+SHA was better than those of CI+PHA (P<0.05) and CI (P<0.05). The language ability and learning ability of CI-SHA was nearly equal to those of the other two groups. The prelingual deaf children should take much more time on rehabilitation. The effect of rehabilitation for prelingual deaf children who used cochlear implant in one ear and hearing aid in the other depend on the residual hearing level of the other ear. If a prelingual deaf children still has any residual hearing level in the ear opposite to the cochlear implant ear, it is better for him/her to wear a hearing aid in the ear.
Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D
2016-02-01
To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.
Bringing Hearing to the Deaf--Cochlear Implants: a Technical and Personal Account
NASA Astrophysics Data System (ADS)
Shipsey, Ian
2006-04-01
Cochlear implants are the first device to successfully restore neural function. They have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. In this talk the physiology of natural hearing will be reviewed from the perspective of a physicist, and the function of cochlear implants will be described in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. The social implications of cochlear implantation and the future outlook for auditory prostheses will also be discussed.
Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.
Chung, King; McKibben, Nicholas
2011-10-01
Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before and after the pre-emphasis filter, were analyzed. Correlation coefficients between speech recognition scores and crest factors of wind noise before and after pre-emphasis filtering were also calculated. Listeners obtained higher scores using the omnidirectional than the directional microphone mode at 13.5 m/sec, but they obtained similar speech recognition scores for the two microphone modes at 4.5 m/sec. Higher correlation coefficients were obtained between speech recognition scores and crest factors of wind noise after pre-emphasis filtering rather than before filtering. Cochlear implant users would benefit from both directional and omnidirectional microphones to reduce far-field background noise and near-field wind noise. Automatic microphone switching algorithms can be more effective if the incoming signal were analyzed after pre-emphasis filters for microphone switching decisions. American Academy of Audiology.
Exploring the Language and Literacy Outcomes of Pediatric Cochlear Implant Users
Spencer, Linda J.; Barker, Brittan A.; Tomblin, J. Bruce
2011-01-01
Objective The principal goal of this study was to investigate the relationship between language and literacy (i.e., reading and writing) skills in pediatric cochlear implant users. A peripheral objective was to identify the children's skills that were in need of remediation and subsequently to provide suggestions for remedial programming. It was predicted that the robust language skills often associated with children who have cochlear implant experience would facilitate the development of literacy skills. It was further proposed that the language and literacy skills of pediatric cochlear implant users would approximate the language and literacy skills of children with normal hearing. Design Sixteen pediatric cochlear implant users' language and literacy skills were evaluated and then compared with a reference group of 16 age-matched, normal-hearing children. All 32 participants were educated in mainstream classes within the public school system in the Midwest. The “Sentence Formulation” and “Concepts and Directions” subtests of the Clinical Evaluation of Language Fundamentals-3 test were used to evaluate receptive and expressive language skills. Reading comprehension was evaluated with the “Paragraph Comprehension” subtest of the Woodcock Reading Mastery Test. Performance measures for the writing analyses included productivity, complexity and grammaticality measures. Results Children with cochlear implants performed within 1 SD of the normal-hearing, age-matched children on measures of language comprehension, reading comprehension and writing accuracy. However, the children with cochlear implants performed significantly poorer than the children with normal hearing on the expressive “Sentence Formulation” subtest. The cochlear implant users also produced fewer words on the written narrative task than did the normal-hearing children, although there was not a significant difference between groups with respect to total words per clause. Furthermore there was a strong correlation between language performance and reading performance, as well as language performance and total words produced on the written performance measure for the children using cochlear implants. Conclusions The results of this study suggest that the language skills of pediatric cochlear implant users are related to and correlated with the development of literacy skills within these children. Consequently, the performance of the cochlear implant users, on various language and literacy measures, compared favorably to an age-matched group of children with normal hearing. There were significant differences in the ability of the cochlear implant users to correctly utilize grammatical structures such as conjunctions and correct verb forms when they were required to formulate written and oral sentences. Given this information, it would be appropriate for their educational or remedial language programs to emphasize the use and development of these structures. PMID:12799546
Impact of socioeconomic factors on paediatric cochlear implant outcomes.
Sharma, Shalabh; Bhatia, Khyati; Singh, Satinder; Lahiri, Asish Kumar; Aggarwal, Asha
2017-11-01
The study was aimed at evaluating the impact of certain socioeconomic factors such as family income, level of parents' education, distance between the child's home and auditory verbal therapy clinic, and age of the child at implantation on postoperative cochlear implant outcomes. Children suffering from congenital bilateral profound sensorineural hearing loss and a chronologic age of 4 years or younger at the time of implantation were included in the study. Children who were able to complete a prescribed period of a 1-year follow-up were included in the study. These children underwent cochlear implantation surgery, and their postoperative outcomes were measured and documented using categories of auditory perception (CAP), meaningful auditory integration (MAIS), and speech intelligibility rating (SIR) scores. Children were divided into three groups based on the level of parental education, family income, and distance of their home from the rehabilitation-- auditory verbal therapy clinic. A total of 180 children were studied. The age at implantation had a significant impact on the postoperative outcomes, with an inverse correlation. The younger the child's age at the time of implantation, the better were the postoperative outcomes. However, there were no significant differences among the CAP, MAIS, and SIR scores and each of the three subgroups. Children from families with an annual income of less than $7,500, between $7,500 and $15,000, and more than $15,000 performed equally well, except for significantly higher SIR scores in children with family incomes more than $15,000. Children with of parents who had attended high school or possessed a bachelor's or Master's master's degree had similar scores, with no significant difference. Also, distance from the auditory verbal therapy clinic failed to have any significantimpact on a child's performance. These results have been variable, similar to those of previously published studies. A few of the earlier studies concurred with our results, but most of the studies had suggested that children in families of higher socioeconomic status had have better speech and language acquisition. Cochlear implantation significantly improves auditory perception and speech intelligibility of children suffering from profound sensorineural hearing loss. Younger The younger the age at implantation, the better are the results. Hence, early implantation should be promoted and encouraged. Our study suggests that children who followed the designated program of postoperative mapping and auditory verbal therapy for a minimum period of 1 year seemed to do equally well in terms of hearing perception and speech intelligibility, irrespective of the socioeconomic status of the family. Further studies are essential to assess the impact of these factors on long-term speech acquisition andlanguage development. Copyright © 2017 Elsevier B.V. All rights reserved.
Lang, S; Leistner, S; Sandrieser, P; Kröger, B J
2009-05-01
Early vocal development of German-speaking cochlear implant recipients has rarely been assessed so far. There-fore the purpose of this study was to describe the early vocal development following successful implantation. A case study was designed to assess the temporal progression of early vocal development in a young cochlear implant recipient who was bilaterally implanted at the age of 8;3 months. Data were collected during one year by recording parent-child interactions on a monthly basis. The first recording was made before the onset of the signal-processors, the 12 following recordings were made during the first year of implant use. The child's vocalizations were classified according to the vocalization categories and developmental levels from the Stark Assessment of Early Vocal Development--Revised (SAEVD-R). This assessment tool was translated into German in this study and used with German-speaking children for the first time. It allows a coding of prelinguistic utterances via auditory perceptual analysis. The results show an overall decrease of early vocalizations and an increase of speech-like vowels and consonants. In the first six months no apparent progress took place; The child produced almost exclusively vocalizations from Levels 1-3. In the second half of the year an increase of canonical utterances (Level 4) and advanced forms (Level 5) was observed. However, vocalizations beyond the canonical babbling phase, especially vocants and closants as well as their combinations, continued to be dominant throughout the first year of implant use. The progress of development of the child investigated in this study is comparable to other children implanted at young age who had also been assessed with the SAEVD-R. In comparison to normal-hearing children, the implanted child's development seemed to progress slightly faster. Interrater- and intrarater-reliability using the SAEVD-R were measured for two independent observers and for a first and second coding procedure and revealed to be acceptable to good. The use of SAEVD-R for an implanted German-speaking child allowed the investigation of prelinguistic vocal development before the onset of words. The fact that early vocalizations remain the dominant form throughout the first year of hearing experience emphasizes the importance of documenting and analysing prelinguistic vocal development in order to monitor progression of speech acquisition.
Cochlear implants and medical tourism.
McKinnon, Brian J; Bhatt, Nishant
2010-09-01
To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.
Powell, Harry R F; Birman, Catherine S
2015-01-01
The aim of this study was to assess if large vestibular aqueduct syndrome (LVAS), with the increase in perilymphatic pressure, affects impedance changes over time with different types of Cochlear(®) implant electrode arrays Contour, Straight, and CI 422. To report speech perception outcomes for these cochlear implant recipients. Retrospective case review of impedance levels and categories of auditory performance. Impedance data were collected at switch on, 1 month, 3, 6, 12, and 24 months after cochlear implantation and compared with control (non-LVAS cochlear implant recipient) data for each array type. Forty-seven patients with exclusive LVAS and no other vestibulocochlear abnormalities or other identifiable cause of deafness were eligible for inclusion in the study. In LVAS patients, there was a significant difference in impedance between the three types of device (P < 0.0001). Time since switch on was associated with a decrease in impedance for all three devices (P < 0.0001). The mean impedance reduced between switch on and 1 month and remained relatively constant thereafter. Sound variation with softening of sounds was seen in four CI 422 (Straight Research Array) recipients due to ongoing fluctuations in electrode compliance. For all three array types, there was no significant difference in the mean impedance between the LVAS patients and controls over the first 12 months. In keeping with previous studies cochlear implant recipients with LVAS hear very well through the cochlear implant.
Parents' Views on Changing Communication after Cochlear Implantation
ERIC Educational Resources Information Center
Watson, Linda M.; Hardie, Tim; Archbold, Sue M.; Wheeler, Alexandra
2008-01-01
We sent questionnaires to families of all 288 children who had received cochlear implants at one center in the United Kingdom at least 5 years previously. Thus, it was a large, unselected group. We received 142 replies and 119 indicated that the child and family had changed their communication approach following cochlear implantation. In 113 cases…
Changes in Speech Production in an Early Deafened Adult with a Cochlear Implant
ERIC Educational Resources Information Center
Wong, Patrick C. M.
2007-01-01
Background and Aims: The current study is a first investigation reporting the speech production characteristics of an early deafened adult cochlear implant user after a course of speech-language treatment. Methods and Procedures: The participant is culturally deaf and received the cochlear implant when she was 43 years old. A 24-week ABCABC…
ERIC Educational Resources Information Center
Bertram, Bodo
2004-01-01
In recent years, parents of children with hearing loss and various additional disabilities have shown increasing interest in cochlear implants. This article describes how the program in Hanover, Germany is attempting to respond to this interest. It discusses the selection process for children who receive cochlear implants who have multiple…
Spelling in Written Stories by School-Age Children with Cochlear Implants
ERIC Educational Resources Information Center
Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel
2016-01-01
This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…
Comparing Binaural Pre-processing Strategies II
Hu, Hongmei; Krawczyk-Becker, Martin; Marquardt, Daniel; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Bomke, Katrin; Plotz, Karsten; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias
2015-01-01
Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT50) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT50 improvements measured in bilaterally implanted CI users. PMID:26721921
Auditory cortical responses in patients with cochlear implants
Burdo, S; Razza, S; Di Berardino, F; Tognola, G
2006-01-01
Summary Currently, the most commonly used electrophysiological tests for cochlear implant evaluation are Averaged Electrical Voltages (AEV), Electrical Advisory Brainstem Responses (EABR) and Neural Response Telemetry (NRT). The present paper focuses on the study of acoustic auditory cortical responses, or slow vertex responses, which are not widely used due to the difficulty in recording, especially in young children. Aims of this study were validation of slow vertex responses and their possible applications in monitoring postimplant results, particularly restoration of hearing and auditory maturation. In practice, the use of tone-bursts, also through hearing aids or cochlear implants, as in slow vertex responses, allows many more frequencies to be investigated and louder intensities to be reached than with other tests based on a click as stimulus. Study design focused on latencies of N1 and P2 slow vertex response peaks in cochlear implants. The study population comprised 45 implant recipients (aged 2 to 70 years), divided into 5 different homogeneous groups according to chronological age, age at onset of deafness, and age at implantation. For each subject, slow vertex responses and free-field auditory responses (PTAS) were recorded for tone-bursts at 500 and 2000 Hz before cochlear implant surgery (using hearing aid amplification) and during scheduled sessions at 3rd and 12th month after implant activation. Results showed that N1 and P2 latencies decreased in all groups starting from 3rd through 12th month after activation. Subjects implanted before school age or at least before age 8 yrs showed the widest latency changes. All subjects showed a reduction in the gap between subjective thresholds (obtained with free field auditory responses) and objective thresholds (obtained with slow vertex responses), obtained in presurgery stage and after cochlear implant. In conclusion, a natural evolution of neurophysiological cortical activities of the auditory pathway, over time, was found especially in young children with prelingual deafness and implanted in preschool age. Cochlear implantation appears to provide hearing restoration, demonstrated by the sharp reduction of the gap between subjective free field auditory responses and slow vertex responses threshold obtained with hearing aids vs. cochlear implant. PMID:16886849
de Kleijn, Jasper L; van Kalmthout, Ludwike W M; van der Vossen, Martijn J B; Vonck, Bernard M D; Topsakal, Vedat; Bruijnzeel, Hanneke
2018-05-24
Although current guidelines recommend cochlear implantation only for children with profound hearing impairment (HI) (>90 decibel [dB] hearing level [HL]), studies show that children with severe hearing impairment (>70-90 dB HL) could also benefit from cochlear implantation. To perform a systematic review to identify audiologic thresholds (in dB HL) that could serve as an audiologic candidacy criterion for pediatric cochlear implantation using 4 domains of speech and language development as independent outcome measures (speech production, speech perception, receptive language, and auditory performance). PubMed and Embase databases were searched up to June 28, 2017, to identify studies comparing speech and language development between children who were profoundly deaf using cochlear implants and children with severe hearing loss using hearing aids, because no studies are available directly comparing children with severe HI in both groups. If cochlear implant users with profound HI score better on speech and language tests than those with severe HI who use hearing aids, this outcome could support adjusting cochlear implantation candidacy criteria to lower audiologic thresholds. Literature search, screening, and article selection were performed using a predefined strategy. Article screening was executed independently by 4 authors in 2 pairs; consensus on article inclusion was reached by discussion between these 4 authors. This study is reported according to the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. Title and abstract screening of 2822 articles resulted in selection of 130 articles for full-text review. Twenty-one studies were selected for critical appraisal, resulting in selection of 10 articles for data extraction. Two studies formulated audiologic thresholds (in dB HLs) at which children could qualify for cochlear implantation: (1) at 4-frequency pure-tone average (PTA) thresholds of 80 dB HL or greater based on speech perception and auditory performance subtests and (2) at PTA thresholds of 88 and 96 dB HL based on a speech perception subtest. In 8 of the 18 outcome measures, children with profound HI using cochlear implants performed similarly to children with severe HI using hearing aids. Better performance of cochlear implant users was shown with a picture-naming test and a speech perception in noise test. Owing to large heterogeneity in study population and selected tests, it was not possible to conduct a meta-analysis. Studies indicate that lower audiologic thresholds (≥80 dB HL) than are advised in current national and manufacturer guidelines would be appropriate as audiologic candidacy criteria for pediatric cochlear implantation.
Meyer, Ted A.; Frisch, Stefan A.; Pisoni, David B.; Miyamoto, Richard T.; Svirsky, Mario A.
2012-01-01
Hypotheses Do cochlear implants provide enough information to allow adult cochlear implant users to understand words in ways that are similar to listeners with acoustic hearing? Can we use a computational model to gain insight into the underlying mechanisms used by cochlear implant users to recognize spoken words? Background The Neighborhood Activation Model has been shown to be a reasonable model of word recognition for listeners with normal hearing. The Neighborhood Activation Model assumes that words are recognized in relation to other similar-sounding words in a listener’s lexicon. The probability of correctly identifying a word is based on the phoneme perception probabilities from a listener’s closed-set consonant and vowel confusion matrices modified by the relative frequency of occurrence of the target word compared with similar-sounding words (neighbors). Common words with few similar-sounding neighbors are more likely to be selected as responses than less common words with many similar-sounding neighbors. Recent studies have shown that several of the assumptions of the Neighborhood Activation Model also hold true for cochlear implant users. Methods Closed-set consonant and vowel confusion matrices were obtained from 26 postlingually deafened adults who use cochlear implants. Confusion matrices were used to represent input errors to the Neighborhood Activation Model. Responses to the different stimuli were then generated by the Neighborhood Activation Model after incorporating the frequency of occurrence counts of the stimuli and their neighbors. Model outputs were compared with obtained performance measures on the Consonant-Vowel Nucleus-Consonant word test. Information transmission analysis was used to assess whether the Neighborhood Activation Model was able to successfully generate and predict word and individual phoneme recognition by cochlear implant users. Results The Neighborhood Activation Model predicted Consonant-Vowel Nucleus-Consonant test words at levels similar to those correctly identified by the cochlear implant users. The Neighborhood Activation Model also predicted phoneme feature information well. Conclusion The results obtained suggest that the Neighborhood Activation Model provides a reasonable explanation of word recognition by postlingually deafened adults after cochlear implantation. It appears that multichannel cochlear implants give cochlear implant users access to their mental lexicons in a manner that is similar to listeners with acoustic hearing. The lexical properties of the test stimuli used to assess performance are important to spoken-word recognition and should be included in further models of the word recognition process. PMID:12851554
Bruijnzeel, Hanneke; Bezdjian, Aren; Lesinski-Schiedat, Anke; Illg, Angelika; Tzifa, Konstance; Monteiro, Luisa; Volpe, Antonio Della; Grolman, Wilko; Topsakal, Vedat
2017-11-01
International guidelines indicate that children with profound hearing loss should receive a cochlear implant (CI) soon after diagnosis in order to optimize speech and language rehabilitation. Although prompt rehabilitation is encouraged by current guidelines, delays in cochlear implantation are still present. This study investigated whether European countries establish timely pediatric CI care based on epidemiological, commercial, and clinical data. An estimation of the number of pediatric CI candidates in European countries was performed and compared to epidemiological (Euro-CIU), commercial (Cochlear ® ), and clinical (institutional) age-at-implantation data. The ages at implantation of pediatric patients in eight countries (the Netherlands, Belgium, Germany, the United Kingdom, France, Turkey, Portugal, and Italy) between 2005 and 2015 were evaluated. From 2010 onwards, over 30% of the pediatric CI candidates were implanted before 24 months of age. Northern European institutions implanted children on average around 12 months of age, whereas southern European institutions implanted children after 18 months of age. The Netherlands and Germany implanted earliest (between 6 and 11 months). Implemented newborn hearing screening programs and reimbursement rates of CIs vary greatly within Europe due to local, social, financial, and political differences. However, internationally accepted recommendations are applicable to this heterogeneous European CI practice. Although consensus on early pediatric cochlear implantation exists, this study identified marked delays in European care. Regardless of the great heterogeneity in European practice, reasons for latency should be identified on a national level and possibilities to prevent avoidable future implantation delays should be explored to provide national recommendations.
Scala vestibuli cochlear implantation in patients with partially ossified cochleas.
Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari
2002-11-01
Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.
... newsroom@entnet.org . A cochlear implant is an electronic device that restores partial hearing to individuals with ... An internal component that consists of a small electronic device that is surgically implanted under the skin ...
Experiences from Auditory Brainstem Implantation (ABIs) in four paediatric patients.
Lundin, Karin; Stillesjö, Fredrik; Nyberg, Gunnar; Rask-Andersen, Helge
2016-01-01
Indications for auditory brainstem implants (ABIs) have been widened from patients with neurofibromatosis type 2 (NF2) to paediatric patients with congenital cochlear malformations, cochlear nerve hypoplasia/aplasia, or cochlear ossification after meningitis. We present four ABI surgeries performed in children at Uppsala University Hospital in Sweden since 2009. Three children were implanted with implants from Cochlear Ltd. (Lane Cove, Australia) and one child with an implant from MedEl GMBH (Innsbruck, Austria). A boy with Goldenhar syndrome was implanted with a Cochlear Nucleus ABI24M at age 2 years (patient 1). Another boy with CHARGE syndrome was implanted with a Cochlear Nucleus ABI541 at age 2.5 years (patient 2). Another boy with post-ossification meningitis was implanted with a Cochlear Nucleus ABI24M at age 4 years (patient 3). A girl with cochlear aplasia was implanted with a MedEl Synchrony ABI at age 3 years (patient 4). In patients 1, 2, and 3, the trans-labyrinthine approach was used, and in patient 4 the retro-sigmoid approach was used. Three of the four children benefited from their ABIs and use it full time. Two of the full time users had categories of auditory performance (CAP) score of 4 at their last follow up visit (6 and 2.5 years postoperative) which means they can discriminate consistently any combination of two of Ling's sounds. One child has not been fully evaluated yet, but is a full time user and had CAP 2 (responds to speech sounds) after 3 months of ABI use. No severe side or unpleasant stimulation effects have been observed so far. There was one case of immediate electrode migration and one case of implant device failure after 6.5 years. ABI should be considered as an option in the rehabilitation of children with similar diagnoses.
[Pre-operation evaluation and intra-operation management of cochlear implantation].
Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning
2004-10-01
To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.
Congenitally deafblind children and cochlear implants: effects on communication.
Dammeyer, Jesper
2009-01-01
There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2 years of age. Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about CI in their deafblind children. Benefits of CI in this cohort of children included improved attention and emotional response as well as greater use of objects in interaction with adults. The best overall outcome of CI is not spoken language but better communication.
Cejas, Ivette; Hoffman, Michael F; Quittner, Alexandra L
2015-01-01
The number of children with hearing loss with additional disabilities receiving cochlear implantation has increased dramatically over the past decade. However, little is known about their auditory and speech and language development following implantation. The purpose of this review is to evaluate the effects of cochlear implantation on the most common genetic and developmental disorders in children with hearing loss. Benefits of cochlear implantation for children with autism spectrum disorder, developmental delay, CHARGE syndrome, cerebral palsy, learning disorders, Usher syndrome, Waardenburg syndrome, and attention deficit/hyperactivity disorder are reviewed. Our review indicates that children with hearing loss and additional disabilities benefit from cochlear implantation, especially when implanted early. Thus, early interventions seem as important for these children as for deaf children without additional disabilities. Comparisons of outcomes across these disabilities indicate that children with little to no cognitive impairment (eg, Waardenburg sydrome, attention deficit hyperactivity disorder) have better outcomes than those with greater deficits in intellectual functioning (eg, autism, CHARGE syndrome). In addition, parents of children with hearing loss and additional disabilities report higher levels of parenting stress and greater child behavior problems than those without comorbid diagnoses. However, these parents are as sensitive when interacting with their children as parents with typically developing children using cochlear implantation. Given these results, it is critical to evaluate these children's developmental milestones to provide early implantation and intervention, appropriately counsel families regarding realistic expectations for the implant, and facilitate family adaptation.
Cejas, Ivette; Hoffman, Michael F; Quittner, Alexandra L
2015-01-01
The number of children with hearing loss with additional disabilities receiving cochlear implantation has increased dramatically over the past decade. However, little is known about their auditory and speech and language development following implantation. The purpose of this review is to evaluate the effects of cochlear implantation on the most common genetic and developmental disorders in children with hearing loss. Benefits of cochlear implantation for children with autism spectrum disorder, developmental delay, CHARGE syndrome, cerebral palsy, learning disorders, Usher syndrome, Waardenburg syndrome, and attention deficit/hyperactivity disorder are reviewed. Our review indicates that children with hearing loss and additional disabilities benefit from cochlear implantation, especially when implanted early. Thus, early interventions seem as important for these children as for deaf children without additional disabilities. Comparisons of outcomes across these disabilities indicate that children with little to no cognitive impairment (eg, Waardenburg sydrome, attention deficit hyperactivity disorder) have better outcomes than those with greater deficits in intellectual functioning (eg, autism, CHARGE syndrome). In addition, parents of children with hearing loss and additional disabilities report higher levels of parenting stress and greater child behavior problems than those without comorbid diagnoses. However, these parents are as sensitive when interacting with their children as parents with typically developing children using cochlear implantation. Given these results, it is critical to evaluate these children’s developmental milestones to provide early implantation and intervention, appropriately counsel families regarding realistic expectations for the implant, and facilitate family adaptation. PMID:29388595
Cochlear implantation in Waardenburg syndrome: The Indian scenario.
Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani
2010-10-01
Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.
Libyan cochlear implant programme: achievements, difficulties, and future goals
Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya
2011-01-01
Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies. PMID:21694783
Libyan cochlear implant programme: achievements, difficulties, and future goals.
Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya
2011-01-01
Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.
Temporal Stability of Music Perception and Appraisal Scores of Adult Cochlear Implant Recipients
Gfeller, Kate; Jiang, Dingfeng; Oleson, Jacob; Driscoll, Virginia; Knutson, John F.
2010-01-01
Background An extensive body of literature indicates that cochlear implants are effective in supporting speech perception of persons with severe to profound hearing losses who do not benefit to any great extent from conventional hearing aids. Adult CI recipients tend to show significant improvement in speech perception within 3 months following implantation as a result of mere experience. Furthermore, CI recipients continue to show modest improvement as long as 5 years post implantation. In contrast, data taken from single testing protocols of music perception and appraisal indicate that CIs are less than ideal in transmitting important structural features of music, such as pitch, melody and timbre. However, there is presently little information documenting changes in music perception or appraisal over extended time as a result of mere experience. Purpose This study examined two basic questions: 1) Do adult CI recipients show significant improvement in perceptual acuity or appraisal of specific music listening tasks when tested in two consecutive years? 2) If there are tasks for which CI recipients show significant improvement with time, are there particular demographic variables that predict those CI recipients most likely to show improvement with extended CI use? Research Design A longitudinal cohort study. Implant recipients return annually for visits to the clinic. Study Sample The study included 209 adult cochlear implant recipients with at least 9 months implant experience before their first year measurement. Data collection and analysis Outcomes were measured on the patient’s annual visit in two consecutive years. Paired t-tests were used to test for significant improvement from one year to the next. Those variables demonstrating significant improvement were subjected to regression analyses performed to detect the demographic variables useful in predicting said improvement. Results There were no significant differences in music perception outcomes as a function of type of device or processing strategy used. Only familiar melody recognition (FMR) and recognition of melody excerpts with lyrics (MERT-L) showed significant improvement from one year to the next. After controlling for the baseline value, hearing aid use, months of use, music listening habits after implantation and formal musical training in elementary school were significant predictors of FMR improvement. Bilateral CI use, formal musical training in high school and beyond, and a measure of sequential cognitive processing were significant predictors of MERT-L improvement. Conclusions These adult CI recipients as a result of mere experience demonstrated fairly consistent music perception and appraisal on measures gathered in two consecutive years. Gains made tend to be modest, and can be associated with characteristics such as use of hearing aids, listening experiences, or bilateral use (in the case of lyrics). These results have implications for counseling of CI recipients with regard to realistic expectations and strategies for enhancing music perception and enjoyment. PMID:20085197
Single and Multiple Microphone Noise Reduction Strategies in Cochlear Implants
Azimi, Behnam; Hu, Yi; Friedland, David R.
2012-01-01
To restore hearing sensation, cochlear implants deliver electrical pulses to the auditory nerve by relying on sophisticated signal processing algorithms that convert acoustic inputs to electrical stimuli. Although individuals fitted with cochlear implants perform well in quiet, in the presence of background noise, the speech intelligibility of cochlear implant listeners is more susceptible to background noise than that of normal hearing listeners. Traditionally, to increase performance in noise, single-microphone noise reduction strategies have been used. More recently, a number of approaches have suggested that speech intelligibility in noise can be improved further by making use of two or more microphones, instead. Processing strategies based on multiple microphones can better exploit the spatial diversity of speech and noise because such strategies rely mostly on spatial information about the relative position of competing sound sources. In this article, we identify and elucidate the most significant theoretical aspects that underpin single- and multi-microphone noise reduction strategies for cochlear implants. More analytically, we focus on strategies of both types that have been shown to be promising for use in current-generation implant devices. We present data from past and more recent studies, and furthermore we outline the direction that future research in the area of noise reduction for cochlear implants could follow. PMID:22923425
Language, Mental State Vocabulary, and False Belief Understanding in Children with Cochlear Implants
ERIC Educational Resources Information Center
Peters, Kimberly; Remmel, Ethan; Richards, Debra
2009-01-01
Purpose: This study examined false belief understanding and its predictors in school-age children who are deaf with cochlear implants and who use spoken language. Method: False belief understanding was measured through an explanation-of-action task in 30 children between the ages of 3 and 12 years who used cochlear implants. Children told a…
Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era
ERIC Educational Resources Information Center
Valente, Joseph Michael
2011-01-01
The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…
ERIC Educational Resources Information Center
National Institutes of Health (DHHS), Bethesda, MD.
This paper reports the results of a Consensus Development Conference on Cochlear Implants sponsored by the National Institutes of Health to improve the hearing of children and adults with hearing impairments. The following questions are addressed: (1) Who is a suitable candidate for a cochlear implant? (2) What are the advantages and disadvantages…
Congenitally Deafblind Children and Cochlear Implants: Effects on Communication
ERIC Educational Resources Information Center
Dammeyer, Jesper
2009-01-01
There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…
ERIC Educational Resources Information Center
Zaidman-Zait, Anat; Jamieson, Janet R.
2004-01-01
The present study has three purposes: (a) to determine who disseminates information on cochlear implants on the Web; (b) to describe a representative sample of Web sites that disseminate information on cochlear implants, with a focus on the content topics and their relevance to parents of deaf children; and (c) to discuss the practical issues of…
Benefit of Wearing a Hearing Aid on the Unimplanted Ear in Adult Users of a Cochlear Implant
ERIC Educational Resources Information Center
Dunn, Camille C.; Tyler, Richard S.; Witt, Shelley A.
2005-01-01
The purpose of this investigation was to document performance of participants wearing a cochlear implant and hearing aid in opposite ears on speech-perception and localization tests. Twelve individuals who wore a cochlear implant and a hearing aid on contralateral ears were tested on their abilities to understand words in quiet and sentences in…
Use of Neural Response Telemetry for Pediatric Cochlear Implants: Current Practice.
Almosnino, Galit; Anne, Samantha; Schwartz, Seth R
2018-06-01
Evaluate usage trends of neural response telemetry (NRT) in cochlear implant centers across the nation and assess reported benefits of intraoperative NRT for pediatric cochlear implant recipients. Survey. All US cochlear implant centers (n = 110). A 15-question multiple-choice survey was distributed electronically to all centers. The survey captured demographic information of all centers, practice patterns surrounding the use of NRT, and the extent to which intraoperative NRT is of benefit. Thirty-two invited participants (29%) completed the survey. A majority of participants reported practicing in an academic center (66%), followed by a hospital setting (19%) and private practice (16%). Seventy-two percent of survey participants reported using NRT for pediatric cochlear implant recipients. Sixty-three percent felt it improved the ability to program at initial activation, and 50% of participants felt that NRT improves satisfaction at initial activation. This study suggests that a majority of surgeons use intraoperative NRT for pediatric cochlear implantation as an additional measure to ensure appropriate electrode placement and improve device activation. Larger studies are needed to better establish the relationship between intraoperative NRT and postoperative outcomes and justify the additional costs associated with intraoperative NRT.
Voice gender identification by cochlear implant users: The role of spectral and temporal resolution
NASA Astrophysics Data System (ADS)
Fu, Qian-Jie; Chinchilla, Sherol; Nogaki, Geraldine; Galvin, John J.
2005-09-01
The present study explored the relative contributions of spectral and temporal information to voice gender identification by cochlear implant users and normal-hearing subjects. Cochlear implant listeners were tested using their everyday speech processors, while normal-hearing subjects were tested under speech processing conditions that simulated various degrees of spectral resolution, temporal resolution, and spectral mismatch. Voice gender identification was tested for two talker sets. In Talker Set 1, the mean fundamental frequency values of the male and female talkers differed by 100 Hz while in Talker Set 2, the mean values differed by 10 Hz. Cochlear implant listeners achieved higher levels of performance with Talker Set 1, while performance was significantly reduced for Talker Set 2. For normal-hearing listeners, performance was significantly affected by the spectral resolution, for both Talker Sets. With matched speech, temporal cues contributed to voice gender identification only for Talker Set 1 while spectral mismatch significantly reduced performance for both Talker Sets. The performance of cochlear implant listeners was similar to that of normal-hearing subjects listening to 4-8 spectral channels. The results suggest that, because of the reduced spectral resolution, cochlear implant patients may attend strongly to periodicity cues to distinguish voice gender.
Verbal Working Memory in Children With Cochlear Implants
Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.
2017-01-01
Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747
Punch, Renée; Hyde, Merv
2011-01-01
Psychosocial factors, including socioemotional well-being, peer relationships, and social inclusion with hearing and deaf peers, are increasingly becoming a focus of research investigating children with cochlear implants. The study reported here extends the largely quantitative findings of previous research through a qualitative analysis of interviews with parents, teachers, and pediatric cochlear implant users themselves in three eastern states of Australia. We interviewed 24 parents, 15 teachers, and 11 children and adolescents. The findings displayed commonalities across the three groups of participants, indicating positive experiences around the children's psychosocial development with their cochlear implants, but also ongoing difficulties communicating in groups of people and problems related to social skills. Some children had little contact with other deaf children (with or without cochlear implants) despite parents and teachers perceiving such contact beneficial. Children attending schools where there were other deaf children valued friendships with both deaf and hearing peers. Adolescence was a particularly difficult time for some as they struggled with feelings of self-consciousness about their deafness and external cochlear implant equipment and worries around friendships, dating, and their future place in the world. Recommendations for practice and further research are made.
Auditory Speech Perception Tests in Relation to the Coding Strategy in Cochlear Implant.
Bazon, Aline Cristine; Mantello, Erika Barioni; Gonçales, Alina Sanches; Isaac, Myriam de Lima; Hyppolito, Miguel Angelo; Reis, Ana Cláudia Mirândola Barbosa
2016-07-01
The objective of the evaluation of auditory perception of cochlear implant users is to determine how the acoustic signal is processed, leading to the recognition and understanding of sound. To investigate the differences in the process of auditory speech perception in individuals with postlingual hearing loss wearing a cochlear implant, using two different speech coding strategies, and to analyze speech perception and handicap perception in relation to the strategy used. This study is prospective cross-sectional cohort study of a descriptive character. We selected ten cochlear implant users that were characterized by hearing threshold by the application of speech perception tests and of the Hearing Handicap Inventory for Adults. There was no significant difference when comparing the variables subject age, age at acquisition of hearing loss, etiology, time of hearing deprivation, time of cochlear implant use and mean hearing threshold with the cochlear implant with the shift in speech coding strategy. There was no relationship between lack of handicap perception and improvement in speech perception in both speech coding strategies used. There was no significant difference between the strategies evaluated and no relation was observed between them and the variables studied.
Effects of a Word-Learning Training on Children With Cochlear Implants
Lund, Emily
2014-01-01
Preschool children with hearing loss who use cochlear implants demonstrate vocabulary delays when compared to their peers without hearing loss. These delays may be a result of deficient word-learning abilities; children with cochlear implants perform more poorly on rapid word-learning tasks than children with normal hearing. This study explored the malleability of rapid word learning of preschoolers with cochlear implants by evaluating the effects of a word-learning training on rapid word learning. A single-subject, multiple probe design across participants measured the impact of the training on children’s rapid word-learning performance. Participants included 5 preschool children with cochlear implants who had an expressive lexicon of less than 150 words. An investigator guided children to identify, repeat, and learn about unknown sets of words in 2-weekly sessions across 10 weeks. The probe measure, a rapid word-learning task with a different set of words than those taught during training, was collected in the baseline, training, and maintenance conditions. All participants improved their receptive rapid word-learning performance in the training condition. The functional relation indicates that the receptive rapid word-learning performance of children with cochlear implants is malleable. PMID:23981321
The importance of electrically evoked stapedial reflex in cochlear implant.
Andrade, Kelly Cristina Lira de; Leal, Mariana de Carvalho; Muniz, Lilian Ferreira; Menezes, Pedro de Lemos; Albuquerque, Katia Maria Gomes de; Carnaúba, Aline Tenório Lins
2014-01-01
The most important stage in fitting a cochlear implant is the identification of its dynamic range. The use of objective measures, in particular the electrically elicited stapedius reflex, may provide suitable assistence for initial fitting of cochlear implant, especially in children or adult with multiple disorders, because they provide specific values that serve as the basis of early cochlear implant programming. Verify through a review the use of the electrically elicited stapedius reflex threshold during the activation and mapping process of cochlear implant. Bibliographical search on the Pubmed and Bireme plataforms, and also on Medline, LILACS and SciELO databases, with standard searches until September 2012, using specific keywords. For the selection and evaluation of scientific studies found in the search, criterias have been established, considering the following aspects: author, year/location, grade of recommendation/level of evidence, purpose, sample, age, mean age in years, evaluative testing, results and conclusion. Among 7,304 articles found, 7,080 were excluded from the title, 152 from the abstract, 17 from the article reading, 43 were repeated and 12 were selected for the study. The electrically elicited stapedius reflex may support when programming the cochlear implant, especially in patients with inconsistent responses.
Cochlear Implantation in the Very Young Child: Issues Unique to the Under-1 Population
Cosetti, Maura; Roland, J. Thomas
2010-01-01
Since the advent of cochlear implantation, candidacy criteria have slowly broadened to include increasingly younger patients. Spurred by evidence demonstrating both perioperative safety and significantly increased speech and language benefit with early auditory intervention, children younger than 12 months of age are now being successfully implanted at many centers. This review highlights the unique challenges involved in cochlear implantation in the very young child, specifically diagnosis and certainty of testing, anesthetic risk, surgical technique, intraoperative testing and postoperative programming, long-term safety, development of receptive and expressive language, and outcomes of speech perception. Overall, the current body of literature indicates that cochlear implantation prior to 1 year of age is both safe and efficacious. PMID:20483813
Çizmeci, Hülya; Çiprut, Ayça
2018-06-01
This study aimed to (1) evaluate the gap filling skills and reading mistakes of students with cochlear implants, and to (2) compare their results with those of their normal-hearing peers. The effects of implantation age and total time of cochlear implant use were analyzed in relation to the subjects' reading skills development. The study included 19 students who underwent cochlear implantation and 20 students with normal hearing, who were enrolled at the 6th to 8th grades. The subjects' ages ranged between 12 and 14 years old. Their reading skills were evaluated by using the Informal Reading Inventory. A significant relationship were found between implanted and normal-hearing students in terms of the percentages of reading error and the percentages of gap filling scores. The average order of the reading errors of students using cochlear implants was higher than that of normal-hearing students. As for the gap filling, the performances of implanted students in the passage are lower than those of their normal-hearing peers. No significant relationship was found between the variables tested in terms of age and duration of implantation on the reading performances of implanted students. Even if they were early implanted, there were significant differences in the reading performances of implanted students compared with those of their normal-hearing peers in older classes. Copyright © 2018 Elsevier B.V. All rights reserved.
King, EB; Hartsock, JJ; O'Leary, SJ; Salt, AN
2013-01-01
Locally-applied drugs can protect residual hearing following cochlear implantation. The influence of cochlear implantation on drug levels in scala tympani (ST) after round window application was investigated in guinea pigs using the marker trimethylphenlyammonium (TMPA) measured in real-time with TMPA-selective microelectrodes. TMPA concentration in the upper basal turn of ST rapidly increased during implantation and then declined due to cerebrospinal fluid entering ST at the cochlear aqueduct and exiting at the cochleostomy. The TMPA increase was found to be caused by the cochleostomy drilling, if the burr tip partially entered ST. TMPA distribution in the second turn was less affected by implantation procedures. These findings show that basal turn drug levels may be changed during implantation and the changes may need to be considered in the interpretation of therapeutic effects of drugs in conjunction with implantation. PMID:24008355
Dislocation of cochlear implant magnet as a complication following MRI.
Murtojärvi, Sarita; Salonen, Jaakko
According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.
Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.
Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J
2012-08-01
Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.
Evidence-based guidelines for recommending cochlear implantation for postlingually deafened adults.
Leigh, Jaime R; Moran, Michelle; Hollow, Rodney; Dowell, Richard C
2016-01-01
Adult selection criteria for cochlear implantation have been developed based on analysis of the post-operative performance of a large group of postlingually deafened adults. Original criteria published in 2004 were reviewed and amended to reflect outcomes currently being achieved by implant recipients. Retrospective review of 12-month post-operative speech perception performance of adults implanted at the Eye and Ear Hospital, Melbourne, Australia. A total of 382 postlingually deafened adults, using a Freedom, Nucleus 5, or CI422 Slim Straight cochlear implant were used to create a comparative set of data. Revised guidelines suggest that adults with postlingual hearing loss can now be considered cochlear implant candidates if they obtain scores of up to 55% for open-set phonemes in quiet in the ear to be implanted. Functional benefit may vary depending on the recipients' contralateral hearing. This study supports the provision of cochlear implants to candidates with significant residual hearing when at least one ear meets the criterion outlined above. Patient-specific counseling is required to ensure the potential to benefit predicted by the current model is acceptable to the individual patient and their family. Counseling regarding functional benefit must take into consideration hearing in the contralateral ear.
Surgical Management of the Pediatric Cochlear Implant Patient.
ERIC Educational Resources Information Center
Cohen, Seth M.; Haynes, David S.
2003-01-01
This article discusses the surgical management of children receiving cochlear implants. It identifies preoperative considerations to select patients likely to benefit, contraindications, some new surgical techniques, complications, special considerations (otitis media, meningitis, head growth, inner ear malformations, and cochlear obstruction).…
Harris, Jill; Kamke, Marc R
2014-11-01
Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Improving speech perception in noise for children with cochlear implants.
Gifford, René H; Olund, Amy P; Dejong, Melissa
2011-10-01
Current cochlear implant recipients are achieving increasingly higher levels of speech recognition; however, the presence of background noise continues to significantly degrade speech understanding for even the best performers. Newer generation Nucleus cochlear implant sound processors can be programmed with SmartSound strategies that have been shown to improve speech understanding in noise for adult cochlear implant recipients. The applicability of these strategies for use in children, however, is not fully understood nor widely accepted. To assess speech perception for pediatric cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE™) array in order to determine whether Nucleus sound processor SmartSound strategies yield improved sentence recognition in noise for children who learn language through the implant. Single subject, repeated measures design. Twenty-two experimental subjects with cochlear implants (mean age 11.1 yr) and 25 control subjects with normal hearing (mean age 9.6 yr) participated in this prospective study. Speech reception thresholds (SRT) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the experimental subjects' everyday program incorporating Adaptive Dynamic Range Optimization (ADRO) as well as with the addition of Autosensitivity control (ASC). Adaptive SRTs with the Hearing In Noise Test (HINT) sentences were obtained for all 22 experimental subjects, and performance-in percent correct-was assessed in a fixed +6 dB SNR (signal-to-noise ratio) for a six-subject subset. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the SmartSound setting on the SRT in noise. The primary findings mirrored those reported previously with adult cochlear implant recipients in that the addition of ASC to ADRO significantly improved speech recognition in noise for pediatric cochlear implant recipients. The mean degree of improvement in the SRT with the addition of ASC to ADRO was 3.5 dB for a mean SRT of 10.9 dB SNR. Thus, despite the fact that these children have acquired auditory/oral speech and language through the use of their cochlear implant(s) equipped with ADRO, the addition of ASC significantly improved their ability to recognize speech in high levels of diffuse background noise. The mean SRT for the control subjects with normal hearing was 0.0 dB SNR. Given that the mean SRT for the experimental group was 10.9 dB SNR, despite the improvements in performance observed with the addition of ASC, cochlear implants still do not completely overcome the speech perception deficit encountered in noisy environments accompanying the diagnosis of severe-to-profound hearing loss. SmartSound strategies currently available in latest generation Nucleus cochlear implant sound processors are able to significantly improve speech understanding in a realistic, semidiffuse noise for pediatric cochlear implant recipients. Despite the reluctance of pediatric audiologists to utilize SmartSound settings for regular use, the results of the current study support the addition of ASC to ADRO for everyday listening environments to improve speech perception in a child's typical everyday program. American Academy of Audiology.
Scala tympani cochleostomy I: results of a survey.
Adunka, Oliver F; Buchman, Craig A
2007-12-01
To assess current surgical techniques for scala tympani cochlear implantation among North American surgeons. A survey was distributed to all cochlear implant surgeons participating in the 2006 William House Cochlear Implant Study Group in Toronto, Canada. Participants were asked to anonymously identify their routine surgical practices. Images of trans-facial recess approaches to the round window and cochlear promontory were used in a multiple-choice fashion to assess the surgeon's typical exposure and cochleostomy location. Returned questionnaires were electronically processed and evaluated. Fifty-five (75%) of 73 returned surveys had adequate data validity and availability. Landmark identification and preferred cochleostomy locations varied greatly. About 20% of surgeons selected cochleostomy locations superior to the round window membrane. Cochleostomy size and location appeared to be influenced by surgical experience and whether or not the round window overhang was drilled off. This survey clearly documents marked variations in surgical techniques for scala tympani cochlear implantation. Future studies should more clearly define the surgical anatomy of this region for appropriate placement of a scala tympani cochleostomy. These findings may ultimately have an impact on hearing and neural preservation cochlear implant surgeries.
Hashemi, Sayed Basir; Rajaeefard, Abdolreza; Norouzpour, Hasan; Tabatabaee, Hamid Reza; Monshizadeh, Leila
2013-03-01
Hearing loss is the most common sensorineural deficiency in human beings. Cochlear implantation is introduced worldwide to treat the severe to profound sensorineural hearing loss, and can result in both speech comprehension and production. The present study aims to determine the effect of cochlear implantation on the improvement of the auditory performance in 2-7 years old children. The present follow-up study is a kind of cohort study which was conducted on 98 children between 2-7 years old who had referred to Fars Cochlear Implantation Center. The patients' information was gathered from their profiles both before and after the operation. The auditory performance score was obtained in 3 stages; 6 months, 1 year, and 2 years after the cochlear implantation through the Cap test. The data was analyzed using the nonparametric Friedman test as well as Mann-Withney, Kruskal-Wallis, and Spearman's Ranks Correlation coefficients. The mean and the median of the auditory performance score of the children who had undergone the cochlear implantation revealed a significant improvement from 6 months to 1 year, and 2 years after the implantation. It showed a significant statistical association between implantation age, type of hearing loss, regular reference, and the length of being present in the rehabilitation program with the auditory performance. It showed no significant association between sex, mother's level of education, being monolingual or bilingual, and family size with the auditory performance. This study revealed that the type of hearing loss, Presence in the rehabilitation program, and the age of cochlear implantation can be major prognostic factors of the response to the treatment, then the country's health policy makers and health planners must executively take into account the infants' hearing screening program during the first 6 month of age.
Gifford, René H; Davis, Timothy J; Sunderhaus, Linsey W; Menapace, Christine; Buck, Barbara; Crosson, Jillian; O'Neill, Lori; Beiter, Anne; Segel, Phil
The primary objective of this study was to assess the effect of electric and acoustic overlap for speech understanding in typical listening conditions using semidiffuse noise. This study used a within-subjects, repeated measures design including 11 experienced adult implant recipients (13 ears) with functional residual hearing in the implanted and nonimplanted ear. The aided acoustic bandwidth was fixed and the low-frequency cutoff for the cochlear implant (CI) was varied systematically. Assessments were completed in the R-SPACE sound-simulation system which includes a semidiffuse restaurant noise originating from eight loudspeakers placed circumferentially about the subject's head. AzBio sentences were presented at 67 dBA with signal to noise ratio varying between +10 and 0 dB determined individually to yield approximately 50 to 60% correct for the CI-alone condition with full CI bandwidth. Listening conditions for all subjects included CI alone, bimodal (CI + contralateral hearing aid), and bilateral-aided electric and acoustic stimulation (EAS; CI + bilateral hearing aid). Low-frequency cutoffs both below and above the original "clinical software recommendation" frequency were tested for all patients, in all conditions. Subjects estimated listening difficulty for all conditions using listener ratings based on a visual analog scale. Three primary findings were that (1) there was statistically significant benefit of preserved acoustic hearing in the implanted ear for most overlap conditions, (2) the default clinical software recommendation rarely yielded the highest level of speech recognition (1 of 13 ears), and (3) greater EAS overlap than that provided by the clinical recommendation yielded significant improvements in speech understanding. For standard-electrode CI recipients with preserved hearing, spectral overlap of acoustic and electric stimuli yielded significantly better speech understanding and less listening effort in a laboratory-based, restaurant-noise simulation. In conclusion, EAS patients may derive more benefit from greater acoustic and electric overlap than given in current software fitting recommendations, which are based solely on audiometric threshold. These data have larger scientific implications, as previous studies may not have assessed outcomes with optimized EAS parameters, thereby underestimating the benefit afforded by hearing preservation.
Shepherd, R K; Clark, G M; Xu, S A; Pyman, B C
1995-03-01
The histopathologic consequence of removing and reimplanting intracochlear electrode arrays on residual auditory nerve fibers is an important issue when evaluating the safety of cochlear prostheses. The authors have examined this issue by implanting multichannel intracochlear electrodes in macaque monkeys. Macaques were selected because of the similarity of the surgical technique used to insert electrodes into the cochlea compared to that in humans, in particular the ability to insert the arrays into the upper basal turn. Five macaques were bilaterally implanted with the Melbourne/Cochlear banded electrode array. Following a minimum implant period of 5 months, the electrode array on one side of each animal was removed and another immediately implanted. The animals were sacrificed a minimum of 5 months following the reinsertion procedure, and the cochleas prepared for histopathologic analysis. Long-term implantation of the electrode resulted in a relatively mild tissue response within the cochlea. Results also showed that inner and outer hair cell survival, although significantly reduced adjacent to the array, was normal in 8 of the 10 cochleas apicalward. Moreover, the electrode reinsertion procedure did not appear to adversely affect this apical hair cell population. Significant new bone formation was frequently observed in both control and reimplanted cochleas close to the electrode fenestration site and was associated with trauma to the endosteum and/or the introduction of bone chips into the cochlea at the time of surgery. Electrode insertion trauma, involving the osseous spiral lamina or basilar membrane, was more commonly observed in reimplanted cochleas. This damage was usually restricted to the lower basal turn and resulted in a more extensive ganglion cell loss. Finally, in a number of cochleas part of the electrode array was located within the scala media or scala vestibuli. These electrodes did not appear to evoke a more extensive tissue response or result in more extensive neural degeneration compared with electrodes located within the scala tympani. In conclusion, the present study has shown that the reimplantation of a multichannel scala, tympani electrode array can be achieved with minimal damage to the majority of cochlear structures. Increased insertion trauma, resulting in new bone formation and spiral ganglion cell loss, can occur in the lower basal turn in cases where the electrode entry point is difficult to identify due to proliferation of granulation and fibrous tissue.
ERIC Educational Resources Information Center
Mok, Mansze; Grayden, David; Dowell, Richard C.; Lawrence, David
2006-01-01
This study aimed to (a) investigate the effect of using a hearing aid in conjunction with a cochlear implant in opposite ears on speech perception in quiet and in noise, (b) identify the speech information obtained from a hearing aid that is additive to the information obtained from a cochlear implant, and (c) explore the relationship between…
Werfel, Krystal L; Hendricks, Alison Eisel
2016-01-01
Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits in language and literacy skills; however, the relation between chronic fatigue and language and literacy skills for children with cochlear implants is unclear. The purpose of this study was to explore subjective ratings of chronic fatigue by children with cochlear implants and their parents, as well as the relation between chronic fatigue and language and literacy skills in this population. Nineteen children with cochlear implants in grades 3 to 6 and one of their parents separately completed a subjective chronic fatigue scale, on which they rated how much the child experienced physical, sleep/rest, and cognitive fatigue over the past month. In addition, children completed an assessment battery that included measures of speech perception, oral language, word reading, and spelling. Children and parents reported different levels of chronic child physical and sleep/rest fatigue. In both cases, parents reported significantly less fatigue than did children. Children and parents did not report different levels of chronic child cognitive fatigue. Child report of physical fatigue was related to speech perception, language, reading, and spelling. Child report of sleep/rest and cognitive fatigue was related to speech perception and language but not to reading or spelling. Parent report of child fatigue was not related to children's language and literacy skills. Taken as a whole, results suggested that parents under-estimate the fatigue experienced by children with cochlear implants. Child report of physical fatigue was robustly related to language and literacy skills. Children with cochlear implants are likely more accurate at reporting physical fatigue than cognitive fatigue. Clinical practice should take fatigue into account when developing treatment plans for children with cochlear implants, and research should continue to develop a comprehensive model of fatigue in children with cochlear implants.
Effect of cochlear implantation on middle ear function: A three-month prospective study.
Wasson, Joseph D; Campbell, Luke; Chambers, Scott; Hampson, Amy; Briggs, Robert J S; O'Leary, Stephen J
2018-05-01
To determine if cochlear implantation has a delayed effect on the middle ear conductive hearing mechanism by measuring laser Doppler vibrometry (LDV) of the tympanic membrane (TM) in both implanted and contralateral control ears preoperatively and 3 months postoperatively, and then comparing the relative change in LDV outcome measures between implanted and control ears. Prospective cohort study. Eleven preoperative adult unilateral cochlear implant recipients in previously unoperated ears with normal anatomy and aerated temporal bones were included in this study. The magnitude and phase angle of umbo velocity transfer function in response to air- conduction (AC) stimulus, and the magnitude of umbo velocity in response to bone- conduction (BC) stimulus were measured in the implant ear and the contralateral control ear preoperatively and 3 months postoperatively and compared. No significant changes in the magnitude or phase angle of TM velocity in response to either AC or BC stimulus were observed in the implanted ear relative to the contralateral control ear 3 months following cochlear implantation. From the results of LDV measurements, it can be said that cochlear implantation has no significant delayed effect on the middle ear conductive mechanism. 4. Laryngoscope, 128:1207-1212, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Öztürk, Erkan; Doruk, Can; Orhan, Kadir Serkan; Çelik, Mehmet; Polat, Beldan; Güldiken, Yahya
2017-06-01
Cochlear implants are mechanical devices used for patients with severe sensory-neural hearing loss, which has an inner magnet. It is proven that 1.5 Tesla magnetic resonance imaging (MRI) scanners are safe to use in patients with cochlear implant. In our patient, the authors aim to introduce a rare complication caused after a 1.5 Tesla MRI scanning and the management of this situation; the reversion of the magnet of the implant without displacement and significance of surgery in management.
American parent perspectives on quality of life in pediatric cochlear implant recipients.
Kumar, Roshini; Warner-Czyz, Andrea; Silver, Cheryl H; Loy, Betty; Tobey, Emily
2015-01-01
Cochlear implantation influences not only communication but also psychosocial outcomes in children with severe to profound hearing loss. Focusing on issues specific to cochlear implantation (e.g., self-reliance, social relations, education, effects of implantation, and supporting the child) may provide a more accurate and relative view of functional status of pediatric cochlear implant (CI) recipients. The present study analyzes parental perspectives of CI-specific health-related quality of life (HRQoL) in children with CIs to determine (a) if parents differentially rate their child's quality of life according to psychosocial domain (e.g., communication, self-reliance, education); (b) if associations exist between quality of life domains specific to cochlear implantation in pediatric implant recipients; and (c) if demographic variables (i.e., chronologic age, age at cochlear implantation, duration of device experience) mediate parent ratings of quality of life in pediatric CI recipients. Parents of 33 children with CIs (mean age, 9.85 years; mean age of CI activation, 2.47 years; mean device experience, 7.47 years) completed a validated condition-specific questionnaire, Children With Cochlear Implants: Parental Perspectives. Parents positively rated most HRQoL domains, although education and effects of implantation received significantly less positive ratings (p < 0.01). Three domains (communication, self-reliance, and well-being) significantly correlated with at least 5 other domains, suggesting that positivity in one domain co-occurs with positivity in other domains. Demographic variables (chronologic age, CI activation age, and duration of CI use) did not correlate significantly with psychosocial outcomes; rather, parents reported positive HRQoL and successful functional use of CI across demographic variables. Parents of children and adolescents with CIs rate overall HRQoL positively across psychosocial domains. Significantly less positive ratings of education and effects of implantation may result from limited access to CI-related accommodations and varying parent expectations, warranting further exploration to maximize psychosocial and performance outcomes in pediatric CI users.
Beeres-Scheenstra, Renske; Ohnsorg, Claudia; Candreia, Claudia; Heinzmann, Sybille; Castellanos, Susana; De Min, Nicola; Linder, Thomas E
2017-07-01
To evaluate foreign language acquisition at school in cochlear implant patients. Cohort study. CI center. Forty three cochlear implants (CI) patients (10-18 yr) were evaluated. CI nonusers and patients with CI-explantation, incomplete datasets, mental retardation, or concomitant medical disorders were excluded. Additional data (type of schooling, foreign language learning, and bilingualism) were obtained with questionnaires. German-speaking children with foreign tuition language (English and/or French) at school were enrolled for further testing. General patient data, auditory data, and foreign language data from both questionnaires and tests were collected and analyzed. Thirty seven out of 43 questionnaires (86%) were completed. Sixteen (43%) were in mainstream education. Twenty-seven CI users (73%) have foreign language learning at school. Fifteen of these were in mainstream education (55%), others in special schooling. From 10 CI users without foreign language learning, one CI user was in mainstream education (10%) and nine patients (90%) were in special schooling. Eleven German-speaking CI users were further tested in English and six additionally in French. For reading skills, the school objectives for English were reached in 7 of 11 pupils (64%) and for French in 3 of 6 pupils (50%). For listening skills, 3 of 11 pupils (27%) reached the school norm in English and none in French. Almost 75% of our CI users learn foreign language(s) at school. A small majority of the tested CI users reached the current school norm for in English and French in reading skills, whereas for hearing skills most of them were not able to reach the norm.
Bilateral versus unilateral cochlear implants in children: a study of spoken language outcomes.
Sarant, Julia; Harris, David; Bennet, Lisa; Bant, Sharyn
2014-01-01
Although it has been established that bilateral cochlear implants (CIs) offer additional speech perception and localization benefits to many children with severe to profound hearing loss, whether these improved perceptual abilities facilitate significantly better language development has not yet been clearly established. The aims of this study were to compare language abilities of children having unilateral and bilateral CIs to quantify the rate of any improvement in language attributable to bilateral CIs and to document other predictors of language development in children with CIs. The receptive vocabulary and language development of 91 children was assessed when they were aged either 5 or 8 years old by using the Peabody Picture Vocabulary Test (fourth edition), and either the Preschool Language Scales (fourth edition) or the Clinical Evaluation of Language Fundamentals (fourth edition), respectively. Cognitive ability, parent involvement in children's intervention or education programs, and family reading habits were also evaluated. Language outcomes were examined by using linear regression analyses. The influence of elements of parenting style, child characteristics, and family background as predictors of outcomes were examined. Children using bilateral CIs achieved significantly better vocabulary outcomes and significantly higher scores on the Core and Expressive Language subscales of the Clinical Evaluation of Language Fundamentals (fourth edition) than did comparable children with unilateral CIs. Scores on the Preschool Language Scales (fourth edition) did not differ significantly between children with unilateral and bilateral CIs. Bilateral CI use was found to predict significantly faster rates of vocabulary and language development than unilateral CI use; the magnitude of this effect was moderated by child age at activation of the bilateral CI. In terms of parenting style, high levels of parental involvement, low amounts of screen time, and more time spent by adults reading to children facilitated significantly better vocabulary and language outcomes. In terms of child characteristics, higher cognitive ability and female sex were predictive of significantly better language outcomes. When family background factors were examined, having tertiary-educated primary caregivers and a family history of hearing loss were significantly predictive of better outcomes. Birth order was also found to have a significant negative effect on both vocabulary and language outcomes, with each older sibling predicting a 5 to 10% decrease in scores. Children with bilateral CIs achieved significantly better vocabulary outcomes, and 8-year-old children with bilateral CIs had significantly better language outcomes than did children with unilateral CIs. These improvements were moderated by children's ages at both first and second CIs. The outcomes were also significantly predicted by a number of factors related to parenting, child characteristics, and family background. Fifty-one percent of the variance in vocabulary outcomes and between 59 to 69% of the variance in language outcomes was predicted by the regression models.
Effects of early auditory experience on the spoken language of deaf children at 3 years of age.
Nicholas, Johanna Grant; Geers, Ann E
2006-06-01
By age 3, typically developing children have achieved extensive vocabulary and syntax skills that facilitate both cognitive and social development. Substantial delays in spoken language acquisition have been documented for children with severe to profound deafness, even those with auditory oral training and early hearing aid use. This study documents the spoken language skills achieved by orally educated 3-yr-olds whose profound hearing loss was identified and hearing aids fitted between 1 and 30 mo of age and who received a cochlear implant between 12 and 38 mo of age. The purpose of the analysis was to examine the effects of age, duration, and type of early auditory experience on spoken language competence at age 3.5 yr. The spoken language skills of 76 children who had used a cochlear implant for at least 7 mo were evaluated via standardized 30-minute language sample analysis, a parent-completed vocabulary checklist, and a teacher language-rating scale. The children were recruited from and enrolled in oral education programs or therapy practices across the United States. Inclusion criteria included presumed deaf since birth, English the primary language of the home, no other known conditions that interfere with speech/language development, enrolled in programs using oral education methods, and no known problems with the cochlear implant lasting more than 30 days. Strong correlations were obtained among all language measures. Therefore, principal components analysis was used to derive a single Language Factor score for each child. A number of possible predictors of language outcome were examined, including age at identification and intervention with a hearing aid, duration of use of a hearing aid, pre-implant pure-tone average (PTA) threshold with a hearing aid, PTA threshold with a cochlear implant, and duration of use of a cochlear implant/age at implantation (the last two variables were practically identical because all children were tested between 40 and 44 mo of age). Examination of the independent influence of these predictors through multiple regression analysis revealed that pre-implant-aided PTA threshold and duration of cochlear implant use (i.e., age at implant) accounted for 58% of the variance in Language Factor scores. A significant negative coefficient associated with pre-implant-aided threshold indicated that children with poorer hearing before implantation exhibited poorer language skills at age 3.5 yr. Likewise, a strong positive coefficient associated with duration of implant use indicated that children who had used their implant for a longer period of time (i.e., who were implanted at an earlier age) exhibited better language at age 3.5 yr. Age at identification and amplification was unrelated to language outcome, as was aided threshold with the cochlear implant. A significant quadratic trend in the relation between duration of implant use and language score revealed a steady increase in language skill (at age 3.5 yr) for each additional month of use of a cochlear implant after the first 12 mo of implant use. The advantage to language of longer implant use became more pronounced over time. Longer use of a cochlear implant in infancy and very early childhood dramatically affects the amount of spoken language exhibited by 3-yr-old, profoundly deaf children. In this sample, the amount of pre-implant intervention with a hearing aid was not related to language outcome at 3.5 yr of age. Rather, it was cochlear implantation at a younger age that served to promote spoken language competence. The previously identified language-facilitating factors of early identification of hearing impairment and early educational intervention may not be sufficient for optimizing spoken language of profoundly deaf children unless it leads to early cochlear implantation.
Rowe, David; Chambers, Scott; Hampson, Amy; Eastwood, Hayden; Campbell, Luke; O'Leary, Stephen
2016-03-01
Cochlear implant recipients show improved speech perception and music appreciation when residual acoustic hearing is combined with the cochlear implant. However, up to one third of patients lose their pre-operative residual hearing weeks to months after implantation, for reasons that are not well understood. This study tested whether this "delayed" hearing loss was influenced by the route of electrode array insertion and/or position of the electrode array within scala tympani in a guinea pig model of cochlear implantation. Five treatment groups were monitored over 12 weeks: (1) round window implant; (2) round window incised with no implant; (3) cochleostomy with medially-oriented implant; (4) cochleostomy with laterally-oriented implant; and (5) cochleostomy with no implant. Hearing was measured at selected time points by the auditory brainstem response. Cochlear condition was assessed histologically, with cochleae three-dimensionally reconstructed to plot electrode paths and estimate tissue response. Electrode array trajectories matched their intended paths. Arrays inserted via the round window were situated nearer to the basilar membrane and organ of Corti over the majority of their intrascalar path compared with arrays inserted via cochleostomy. Round window interventions exhibited delayed, low frequency hearing loss that was not seen after cochleostomy. This hearing loss appeared unrelated to the extent of tissue reaction or injury within scala tympani, although round window insertion was histologically the most traumatic mode of implantation. We speculate that delayed hearing loss was related not to the electrode position as postulated, but rather to the muscle graft used to seal the round window post-intervention, by altering cochlear mechanics via round window fibrosis. Copyright © 2015 Elsevier B.V. All rights reserved.
A software tool for analyzing multichannel cochlear implant signals.
Lai, Wai Kong; Bögli, Hans; Dillier, Norbert
2003-10-01
A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.
A phone-assistive device based on Bluetooth technology for cochlear implant users.
Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F
2003-09-01
Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.
[Cost Analysis of Cochlear Implantation in Adults].
Raths, S; Lenarz, T; Lesinski-Schiedat, A; Flessa, S
2016-04-01
The number of implantation of cochlear implants has steadily risen in recent years. Reasons for this are an extension of indication criteria, demographic change, increased quality of life needs and greater acceptance. The consequences are rising expenditure for statutory health insurance (SHI) for cochlear implantation. A detailed calculation of lifetime costs from SHI's perspective for postlingually deafened adolescents and adults is essential in estimating future cost developments. Calculations are based on accounting data from the Hannover Medical School. With regard to further life expectancy, average costs of preoperative diagnosis, surgery, rehabilitation, follow-ups, processor upgrades and electrical maintenance were discounted to their present value at age of implantation. There is an inverse relation between cost of unilateral cochlear implantation and age of initial implantation. From SHI's perspective, the intervention costs between 36,001 and 68,970 € ($ 42,504-$ 81,429). The largest cost components are initial implantation and processor upgrades. Compared to the UK the cost of cochlear implantation in Germany seems to be significantly lower. In particular the costs of, rehabilitation and maintenance in Germany cause only a small percentage of total costs. Also, the costs during the first year of treatment seem comparatively low. With regard to future spending of SHI due to implant innovations and associated extension of indication, increasing cost may be suspected. © Georg Thieme Verlag KG Stuttgart · New York.
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah
2012-01-01
Purpose To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and post-implant language development and executive function. Method Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (FES) and an inventory of executive function (BRIEF/BRIEF-P). Children’s receptive vocabulary (PPVT-4) and global language skills (PLS-4/CELF-4) were also evaluated. Results The family environments of children with cochlear implants differed from those of normal-hearing children, but not in clinically significant ways. Language development and executive function were found to be atypical, but not uncharacteristic of this clinical population. Families with higher levels of self-reported control had children with smaller vocabularies. Families reporting a higher emphasis on achievement had children with fewer executive function and working memory problems. Finally, families reporting a higher emphasis on organization had children with fewer problems related to inhibition. Conclusions Some of the variability in cochlear implantation outcomes that have protracted periods of development is related to family environment. Because family environment can be modified and enhanced by therapy or education, these preliminary findings hold promise for future work in helping families to create robust language-learning environments that can maximize their child’s potential with a cochlear implant. PMID:22232387
Chang, Andrew; Eastwood, Hayden; Sly, David; James, David; Richardson, Rachael; O'Leary, Stephen
2009-09-01
To protect hearing in an experimental model of cochlear implantation by the application of dexamethasone to the round window prior to surgery. The present study examined the dosage and timing relationships required to optimise the hearing protection. Dexamethasone or saline (control) was absorbed into a pledget of the carboxymethylcellulose and hyaluronic acid and applied to the round window of the guinea pig prior to cochlear implantation. The treatment groups were 2% w/v dexamethasone for 30, 60 and 120min; 20% dexamethasone applied for 30min. Auditory sensitivity was determined pre-operatively, and at 1 week after surgery, with pure-tone auditory brainstem response audiometry (2-32kHz). Cochlear implantation was performed via a cochleostomy drilled into the basal turn of the cochlea, into which a miniature cochlear implant dummy electrode was inserted using soft-surgery techniques. ABR thresholds were elevated after cochlear implantation, maximally at 32kHz and to a lesser extent at lower frequencies. Thresholds were less elevated after dexamethasone treatment, and the hearing protection improved when 2% dexamethasone was applied to the round window for longer periods of time prior to implantation. The time that dexamethasone need be applied to achieve hearing protection could be reduced by increasing the concentration of steroid, with a 20% application for 30min achieving similar levels of protection to a 60min application of 2% dexamethasone. Hearing protection is improved by increasing the time that dexamethasone is applied to the round window prior to cochlear implantation, and the waiting time can be reduced by increasing the steroid concentration. These results suggest that the diffusion dexamethasone through the cochlea is the prime determinant of the extent of hearing protection.
Psarros, Colleen; Love, Sarah
2016-01-01
Newborn hearing screening has led to the early diagnosis of hearing loss in neonates and early device fitting is common, based primarily on electrophysiologic and radiologic information, with some supplementary behavioral measures. Such early fitting of hearing devices, in particular cochlear implants (CIs), has been beneficial to the majority of children implanted under the age of 12 months who meet the cochlear implant candidacy criteria. Comorbidities are common in children with hearing loss, although they may not be evident in neonates and may not emerge until later in infants. Evidence suggests that the child's outcomes are strongly influenced by a range of environmental factors including emotional and social support from the immediate and extended family. Consequently, such factors are important in service planning and service delivery for babies and children receiving CIs. The World Health Organization's International Classification of Functioning, Health and Disability (ICF) can provide a framework to facilitate the holistic management of pediatric cochlear implant recipients. The ICF also can be used to map the progress of recipients over time to highlight emerging issues that require intervention. This article will discuss our preliminary use of the ICF to establish clinical practice; develop advocacy skills among clients and their families; identify eligibility for services such as support in educational settings; enable access to modes of service delivery such as telepractice; provide a conceptual framework for policy and program development for pediatric cochlear implant recipients (i.e., in both disability and health services); and, most importantly, establish a clear pathway for the longitudinal management of the cochlear implant in a child's future. It is anticipated that this model will be applied to other populations receiving cochlear implants through our program. PMID:27489404
Sharma, Anu; Campbell, Julia; Cardon, Garrett
2015-02-01
Cortical development is dependent on extrinsic stimulation. As such, sensory deprivation, as in congenital deafness, can dramatically alter functional connectivity and growth in the auditory system. Cochlear implants ameliorate deprivation-induced delays in maturation by directly stimulating the central nervous system, and thereby restoring auditory input. The scenario in which hearing is lost due to deafness and then reestablished via a cochlear implant provides a window into the development of the central auditory system. Converging evidence from electrophysiologic and brain imaging studies of deaf animals and children fitted with cochlear implants has allowed us to elucidate the details of the time course for auditory cortical maturation under conditions of deprivation. Here, we review how the P1 cortical auditory evoked potential (CAEP) provides useful insight into sensitive period cut-offs for development of the primary auditory cortex in deaf children fitted with cochlear implants. Additionally, we present new data on similar sensitive period dynamics in higher-order auditory cortices, as measured by the N1 CAEP in cochlear implant recipients. Furthermore, cortical re-organization, secondary to sensory deprivation, may take the form of compensatory cross-modal plasticity. We provide new case-study evidence that cross-modal re-organization, in which intact sensory modalities (i.e., vision and somatosensation) recruit cortical regions associated with deficient sensory modalities (i.e., auditory) in cochlear implanted children may influence their behavioral outcomes with the implant. Improvements in our understanding of developmental neuroplasticity in the auditory system should lead to harnessing central auditory plasticity for superior clinical technique. Copyright © 2014 Elsevier B.V. All rights reserved.
Mandal, Joyanta Chandra; Kumar, Suman; Roy, Sumit
2016-12-01
The main goal of this study was to obtain auditory comprehension skills of native Hindi speaking children with cochlear implant and typically developing children across the age of 3-7 years and compare the scores between two groups. A total of sixty Hindi speaking participants were selected for the study. They were divided into two groups- Group-A consisted of thirty children with normal hearing and Group-B thirty children using cochlear implants. To assess the auditory comprehension skills, Test of auditory comprehension in Hindi (TACH) was used. The participant was required to point to one of three pictures which would best correspond to the stimulus presented. Correct answers were scored as 1 and incorrect answers as 0. TACH was administered on for both groups. Independent t-test was applied and it was found that auditory comprehension scores of children using cochlear implant were significantly poorer than the score of children with normal hearing for all three subtests. Pearson's correlation coefficient revealed poor correlation between the scores of children with normal hearing and children using cochlear implant. The results of this study suggest that children using cochlear implant have poor auditory comprehension skills than children with normal hearing. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kant, Anjali R; Banik, Arun A
2017-09-01
The present study aims to use the model-based test Lexical Neighborhood Test (LNT), to assess speech recognition performance in early and late implanted hearing impaired children with normal and malformed cochlea. The LNT was administered to 46 children with congenital (prelingual) bilateral severe-profound sensorineural hearing loss, using Nucleus 24 cochlear implant. The children were grouped into Group 1-(early implantees with normal cochlea-EI); n = 15, 31/2-61/2 years of age; mean age at implantation-3½ years. Group 2-(late implantees with normal cochlea-LI); n = 15, 6-12 years of age; mean age at implantation-5 years. Group 3-(early implantees with malformed cochlea-EIMC); n = 9; 4.9-10.6 years of age; mean age at implantation-3.10 years. Group 4-(late implantees with malformed cochlea-LIMC); n = 7; 7-12.6 years of age; mean age at implantation-6.3 years. The following were the malformations: dysplastic cochlea, common cavity, Mondini's, incomplete partition-1 and 2 (IP-1 and 2), enlarged IAC. The children were instructed to repeat the words on hearing them. Means of the word and phoneme scores were computed. The LNT can also be used to assess speech recognition performance of hearing impaired children with malformed cochlea. When both easy and hard lists of LNT are considered, although, late implantees (with or without normal cochlea), have achieved higher word scores than early implantees, the differences are not statistically significant. Using LNT for assessing speech recognition enables a quantitative as well as descriptive report of phonological processes used by the children.
Cochlear Implantation in Older Adults
Lin, Frank R.; Chien, Wade W.; Li, Lingsheng; Niparko, John K.; Francis, Howard W.
2012-01-01
Cochlear implants allow individuals with severe-to-profound hearing loss access to sound and spoken language. The number of older adults in the United States who are potential candidates for cochlear implantation is approximately 150,000 and will continue to increase with the aging of the population. Should cochlear implantation (CI) be routinely recommended for these older adults, and do these individuals benefit from CI? We reviewed our 12 year experience with cochlear implantation in adults ≥60 years (n = 445) at Johns Hopkins to investigate the impact of CI on speech understanding and to identify factors associated with speech performance. Complete data on speech outcomes at baseline and 1 year post-CI were available for 83 individuals. Our results demonstrate that cochlear implantation in adults ≥60 years consistently improved speech understanding scores with a mean increase of 60. 0% (S. D. 24. 1) on HINT sentences in quiet . The magnitude of the gain in speech scores was negatively associated with age at implantation such that for every increasing year of age at CI the gain in speech scores was 1. 3 percentage points less (95% CI: 0. 6 – 1. 9) after adjusting for age at hearing loss onset. Conversely, individuals with higher pre-CI speech scores (HINT scores between 40–60%) had significantly greater post-CI speech scores by a mean of 10. 0 percentage points (95% CI: 0. 4 – 19. 6) than those with lower pre-CI speech scores (HINT <40%) after adjusting for age at CI and age at hearing loss onset. These results suggest that older adult CI candidates who are younger at implantation and with higher preoperative speech scores obtain the highest speech understanding scores after cochlear implantation with possible implications for current Medicare policy. Finally, we provide an extended discussion of the epidemiology and impact of hearing loss in older adults. Future research of CI in older adults should expand beyond simple speech outcomes to take into account the broad cognitive, social, and physical functioning outcomes that are likely detrimentally impacted by hearing loss and may be mitigated by cochlear implantation. PMID:22932787
Cochlear implanted pupils in Scottish schools: 4-year school attainment data (2000-2004).
Thoutenhoofd, Ernst
2006-01-01
The Achievements of Deaf Pupils in Scotland (ADPS) project has been tracking the educational attainment of deaf pupils in Scotland's schools since 2000. At the time of writing, the database contains records for 1,752 deaf pupils (2000-2005). Here 4-year aggregate educational attainment data are reported for a subset of 152 school-aged deaf pupils with cochlear implants notified to the ADPS database between June 2000 and June 2004. The data describe primary and secondary school results in reading, writing, and math for this subgroup, as well as placement and communication characteristics. The educational attainment of the group of deaf pupils with cochlear implants is clearly marked when the deaf pupil population is disaggregated for hearing loss, achieving comparatively higher average attainment in both 5-14 Curriculum National Tests (Mathematics in particular) and Standard Grades. Therefore the gap in performance relative to the national population data is reduced for those deaf pupils, although it still widens at higher levels of achievement for the National Tests. Although most pupils with cochlear implants are placed in the mainstream, there is no pattern of migration toward mainstream schools. Some deaf pupils with cochlear implants moved out of mainstream to other types of placement, and this has implications for health-economic cost-utility assessments of cochlear implantation that favor mainstream education by drawing upon the relative cost of different placement types. These findings suggest that the ADPS program of research can contribute school outcome data as valuable real-life outcome measures in wider assessments of the benefit of cochlear implants to deaf children and deaf young people.
Plontke, Stefan K; Kösling, Sabrina; Rahne, Torsten
2018-03-01
To describe the technique for surgical tumor removal, cochlear implant (CI) electrode placement and reconstruction of the surgical defect in patients with intracochlear schwannomas. Retrospective case review. Tertiary referral center. Ten patients (five men, five women, mean age 48 ± 12 yr) with profound or severe to profound hearing loss due to intralabyrinthine schwannomas with intracochlear location. Surgical tumor removal through extended round window approach, partial or subtotal cochleoectomy with or without labyrinthectomy and reconstruction of the surgical defect with cartilage, perichondrium or temporal muscle fascia, and bone pâté. Eight patients received a cochlear implant in the same procedure. Retrospective evaluation of clinical outcome including safety aspects (adverse events) and audiological performance at early follow up in cases of cochlear implantation. The tumor was successfully removed in all cases without macroscopic (operation microscope and endoscope) tumor remnants in the bony labyrinth apart from one case with initial transmodiolar growth. One patient needed revision surgery for labyrinthine fistula. At short-term follow up (3-month post-surgery), good hearing results with the cochlear implant were obtained in all but one patient with a word recognition score of 100% for numbers, and 64 ± 14% for monosyllables (at 65 dB SPL in quiet). Surgical tumor removal and cochlear implantation is a promising treatment strategy in the management of intralabyrinthine schwannoma with intracochlear location, further extending the indication range for cochlear implantation. It is, however, of importance to observe the long-term outcome in these patients and to address challenges like follow up with magnetic resonance imaging.
Spoken language development in children following cochlear implantation.
Niparko, John K; Tobey, Emily A; Thal, Donna J; Eisenberg, Laurie S; Wang, Nae-Yuh; Quittner, Alexandra L; Fink, Nancy E
2010-04-21
Cochlear implantation is a surgical alternative to traditional amplification (hearing aids) that can facilitate spoken language development in young children with severe to profound sensorineural hearing loss (SNHL). To prospectively assess spoken language acquisition following cochlear implantation in young children. Prospective, longitudinal, and multidimensional assessment of spoken language development over a 3-year period in children who underwent cochlear implantation before 5 years of age (n = 188) from 6 US centers and hearing children of similar ages (n = 97) from 2 preschools recruited between November 2002 and December 2004. Follow-up completed between November 2005 and May 2008. Performance on measures of spoken language comprehension and expression (Reynell Developmental Language Scales). Children undergoing cochlear implantation showed greater improvement in spoken language performance (10.4; 95% confidence interval [CI], 9.6-11.2 points per year in comprehension; 8.4; 95% CI, 7.8-9.0 in expression) than would be predicted by their preimplantation baseline scores (5.4; 95% CI, 4.1-6.7, comprehension; 5.8; 95% CI, 4.6-7.0, expression), although mean scores were not restored to age-appropriate levels after 3 years. Younger age at cochlear implantation was associated with significantly steeper rate increases in comprehension (1.1; 95% CI, 0.5-1.7 points per year younger) and expression (1.0; 95% CI, 0.6-1.5 points per year younger). Similarly, each 1-year shorter history of hearing deficit was associated with steeper rate increases in comprehension (0.8; 95% CI, 0.2-1.2 points per year shorter) and expression (0.6; 95% CI, 0.2-1.0 points per year shorter). In multivariable analyses, greater residual hearing prior to cochlear implantation, higher ratings of parent-child interactions, and higher socioeconomic status were associated with greater rates of improvement in comprehension and expression. The use of cochlear implants in young children was associated with better spoken language learning than would be predicted from their preimplantation scores.
Athalye, Sheetal; Archbold, Sue; Mulla, Imran; Lutman, Mark; Nikolopoulous, Thomas
2015-09-01
The objective of this survey was to explore the perceptions of implant users/carers and professionals across the UK about current and future cochlear implant service delivery and the challenges. Data were collected via an online questionnaire consisting of totally 22 questions. The questionnaire contained both open- and close-ended questions. Totally, seven hundred and forty-eight responses were received. In spite of the wide range of respondents, there was a broad consensus of opinion across groups. The majority of participants were satisfied with the service they currently receive, but wanted some changes. They reported their current experience of implant services to be mainly driven by decisions made by the implant team. For the future, they preferred the service to be mainly driven by decisions made jointly by the team and the user and/or parent/carer. The majority of participants wanted the cochlear implant services to be integrated into local audiology and other services such as education. Restrictions on number of candidates funded and political decisions and issues were seen as major challenges. Qualitative analysis of the open-ended responses supported the questionnaire responses. This research highlighted the benefits and limitations of the current cochlear implant service delivery as well as the potential implications for the long term. While respondents were generally happy with the current cochlear implant service provision, they expressed some concerns about the long-term sustainability and management, wanting integration into the local services, and more involvement of parents and users in decisions.
Positron Emission Tomography in Cochlear Implant and Auditory Brainstem Implant Recipients.
ERIC Educational Resources Information Center
Miyamoto, Richard T.; Wong, Donald
2001-01-01
Positron emission tomography imaging was used to evaluate the brain's response to auditory stimulation, including speech, in deaf adults (five with cochlear implants and one with an auditory brainstem implant). Functional speech processing was associated with activation in areas classically associated with speech processing. (Contains five…
Skarzynski, Henryk; Lorens, Artur; Kruszynska, Marika; Obrycka, Anita; Pastuszak, Dorota; Skarzynski, Piotr Henryk
2017-07-01
Cochlear implants improve the hearing abilities of individuals with unilateral hearing loss and no tinnitus. The benefit is no different from that seen in patients with unilateral hearing loss and incapacitating tinnitus. To evaluate hearing outcomes after cochlear implantation in individuals with unilateral hearing loss and no tinnitus and compare them to those obtained in a similar group who had incapacitating tinnitus. Six cases who did not experience tinnitus before operation and 15 subjects with pre-operative tinnitus were evaluated with a structured interview, a monosyllabic word test under difficult listening situations, a sound localization test, and an APHAB (abbreviated profile of hearing aid benefit) questionnaire. All subjects used their cochlear implant more than 8 hours a day, 7 days a week. In 'no tinnitus' patients, mean benefit of cochlear implantation was 19% for quiet speech, 15% for speech in noise (with the same signal-to-noise ratio in the implanted and non-implanted ear), and 16% for a more favourable signal-to-noise ratio at the implanted ear. Sound localization error improved by an average of 19°. The global score of APHAB improved by 16%. The benefits across all evaluations did not differ significantly between the 'no tinnitus' and 'tinnitus' groups.
Productivity of lexical categories in French-speaking children with cochlear implants.
Le Normand, M-T; Ouellet, C; Cohen, H
2003-11-01
The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.
Guillen-Ahlers, Hector; Erbe, Christy B; Chevalier, Frédéric D; Montoya, Maria J; Zimmerman, Kip D; Langefeld, Carl D; Olivier, Michael; Runge, Christina L
2018-04-19
Sensorineural hearing loss (SNHL) is a common form of hearing loss that can be inherited or triggered by environmental insults; auditory neuropathy spectrum disorder (ANSD) is a SNHL subtype with unique diagnostic criteria. The genetic factors associated with these impairments are vast and diverse, but causal genetic factors are rarely characterized. A family dyad, both cochlear implant recipients, presented with a hearing history of bilateral, progressive SNHL, and ANSD. Whole-exome sequencing was performed to identify coding sequence variants shared by both family members, and screened against genes relevant to hearing loss and variants known to be associated with SNHL and ANSD. Both family members are successful cochlear implant users, demonstrating effective auditory nerve stimulation with their devices. Genetic analyses revealed a mutation (rs35725509) in the TMTC2 gene, which has been reported previously as a likely genetic cause of SNHL in another family of Northern European descent. This study represents the first confirmation of the rs35725509 variant in an independent family as a likely cause for the complex hearing loss phenotype (SNHL and ANSD) observed in this family dyad. © 2018 The Authors. Molecular Genetics & Genomic Medicine published by Wiley Periodicals, Inc.
Emotional Perception of Music in Children With Bimodal Fitting and Unilateral Cochlear Implant.
Shirvani, Sareh; Jafari, Zahra; Motasaddi Zarandi, Masoud; Jalaie, Shohre; Mohagheghi, Hamed; Tale, Mohammad Reza
2016-06-01
Biological, structural, and acoustical constraints faced by cochlear implant (CI) users can alter the perception of music. Bimodal fitting not only provides bilateral hearing but can also improve auditory skills. This study was conducted to assess the impact of this amplification style on the emotional perception of music among children with hearing loss (HL). Twenty-five children with congenital severe to profound HL and unilateral CIs, 20 children with bimodal fitting, and 30 children with normal hearing participated in this study. Their emotional perceptions of music were measured using a method where children indicated happy or sad feelings induced by music by pointing to pictures of faces showing these emotions. Children with bimodal fitting obtained significantly higher mean scores than children with unilateral CIs for both happy and sad music items and in overall test scores (P < .001). Both groups with HL obtained significantly lower scores than children with normal hearing (P < .001). Bimodal fitting results in a better emotional perception of music compared to unilateral CI. Given the influence of music in neurological and linguistic development and social interactions, it is important to evaluate the possible benefits of bimodal fitting prescriptions for individuals with unilateral CIs. © The Author(s) 2015.
Hudson, V E; Elniel, A; Ughratdar, I; Zebian, B; Selway, R; Lin, J P
2017-01-01
Cochlear implants for sensorineural deafness in children is one of the most successful neuromodulation techniques known to relieve early chronic neurodisability, improving activity and participation. In 2012 there were 324,000 recipients of cochlear implants globally. To compare cochlear implant (CI) neuromodulation with deep brain stimulation (DBS) for dystonia in childhood and explore relations between age and duration of symptoms at implantation and outcome. Comparison of published annual UK CI figures for 1985-2009 with a retrospective cohort of the first 9 years of DBS for dystonia in children at a single-site Functional Neurosurgery unit from 2006 to 14. From 2006 to 14, DBS neuromodulation of childhood dystonia increased by a factor of 3.8 to a total of 126 cases over the first 9 years, similar to the growth in cochlear implants which increased by a factor of 4.1 over a similar period in the 1980s rising to 527 children in 2009. The CI saw a dramatic shift in practice from implantation at >5 years of age at the start of the programme towards earlier implantation by the mid-1990s. Best language results were seen for implantation <5 years of age and duration of cochlear neuromodulation >4 years, hence implantation <1 year of age, indicating that severely deaf, pre-lingual children could benefit from cochlear neuromodulation if implanted early. Similar to initial CI use, the majority of children receiving DBS for dystonia in the first 9 years were 5-15 years of age, when the proportion of life lived with dystonia exceeds 90% thus limiting benefits. Early DBS neuromodulation for acquired motor disorders should be explored to maximise the benefits of dystonia reduction in a period of maximal developmental plasticity before the onset of disability. Learning from cochlear implantation, DBS can become an accepted management option in children under the age of 5 years who have a reduced proportion of life lived with dystonia, and not viewed as a last resort reserved for only the most severe cases where benefits may be at their most limited. Copyright © 2016 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Yanov, Yu K; Kuzovkov, V E; Lilenko, A S; Kostevich, I V; Sugarova, S B; Amonov, A Sh
The mode of the introduction of the active electrode of a cochlear implant into the cochlea remains a key issue as far as cochlear implantation is concerned. Especially much attention has recently been given to the relationship between the anatomical features of the basal region of the cochlea (the so-called 'fish hook') and the possibility to approach it. We have undertaken the attempt to optimize the approach to the tympanic canal (scala tympanica) of the cochlea with a view to reducing to a minimum the risk of an injury to the cochlear structures in the course of cochlear implantation. A total of 35 cadaveric temporal bones were examined to measure the fine structures of the hook region and evaluate the risk of their damages associated with various approaches to the tympanic canal.
Park, Steve; Guan, Xiying; Kim, Youngwan; Creighton, Francis Pete X; Wei, Eric; Kymissis, Ioannis John; Nakajima, Hideko Heidi; Olson, Elizabeth S
2018-01-01
We report the fabrication and characterization of a prototype polyvinylidene fluoride polymer-based implantable microphone for detecting sound inside gerbil and human cochleae. With the current configuration and amplification, the signal-to-noise ratios were sufficiently high for normally occurring sound pressures and frequencies (ear canal pressures >50-60 dB SPL and 0.1-10 kHz), though 10 to 20 dB poorer than for some hearing aid microphones. These results demonstrate the feasibility of the prototype devices as implantable microphones for the development of totally implantable cochlear implants. For patients, this will improve sound reception by utilizing the outer ear and will improve the use of cochlear implants.
Guan, Xiying; Kim, Youngwan; Creighton, Francis (Pete) X.; Wei, Eric; Kymissis, Ioannis(John); Nakajima, Hideko Heidi; Olson, Elizabeth S.
2018-01-01
We report the fabrication and characterization of a prototype polyvinylidene fluoride polymer-based implantable microphone for detecting sound inside gerbil and human cochleae. With the current configuration and amplification, the signal-to-noise ratios were sufficiently high for normally occurring sound pressures and frequencies (ear canal pressures >50–60 dB SPL and 0.1–10 kHz), though 10 to 20 dB poorer than for some hearing aid microphones. These results demonstrate the feasibility of the prototype devices as implantable microphones for the development of totally implantable cochlear implants. For patients, this will improve sound reception by utilizing the outer ear and will improve the use of cochlear implants. PMID:29732950
Yang, Chan Joo; Lee, Jee Yeon; Ahn, Joong Ho; Lee, Kwang-Sun
2016-09-01
This study shows that, in cochlear implantation (CI) surgery, pre-operative caloric test results are not correlated with post-operative outcomes of dizziness or speech perception. To determine the role of pre-operative caloric tests in CI. The records of 95 patients who underwent unilateral CI were reviewed retrospectively. Patients were divided into four groups according to caloric response. Forty-six patients with normal caloric responses were classified as Group A, 19 patients who underwent CI in the ear with worse caloric responses as Group B, 18 patients with bilateral loss of caloric responses as Group C, and 12 patients who underwent CI in the ear with better caloric responses as Group D. Speech performance and post-operative dizziness were compared between the four groups. Speech perception was determined by evaluating consonant-vowel phoneme detection, closed-set word and open-set mono-syllabic and bi-syllabic word identification, and sentence comprehension test scores. The speech perception and aided pure-tone average (PTA) test results at 3 and 6 months and at 1, 2, and 3 years after implantation were not significantly different between Groups A, B, C, and D (p > 0.05). Eight patients (8.4%) reported post-operative dizziness, but there was no significant difference between the four groups (p = 0.627).
Hu, Hongmei; Kollmeier, Birger; Dietz, Mathias
2016-01-01
Although bilateral cochlear implants (BiCIs) have succeeded in improving the spatial hearing performance of bilateral CI users, the overall performance is still not comparable with normal hearing listeners. Limited success can be partially caused by an interaural mismatch of the place-of-stimulation in each cochlea. Pairing matched interaural CI electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, or spatial release from masking. It has been shown in animal experiments that the magnitude of the binaural interaction component (BIC) derived from the wave-eV decreases for increasing interaural place of stimulation mismatch. This motivated the investigation of the suitability of an electroencephalography-based objective electrode-frequency fitting procedure based on the BIC for BiCI users. A 61 channel monaural and binaural electrically evoked auditory brainstem response (eABR) recording was performed in 7 MED-EL BiCI subjects so far. These BiCI subjects were directly stimulated at 60% dynamic range with 19.9 pulses per second via a research platform provided by the University of Innsbruck (RIB II). The BIC was derived for several interaural electrode pairs by subtracting the response from binaural stimulation from their summed monaural responses. The BIC based pairing results are compared with two psychoacoustic pairing methods: interaural pulse time difference sensitivity and interaural pitch matching. The results for all three methods analyzed as a function of probe electrode allow for determining a matched pair in more than half of the subjects, with a typical accuracy of ± 1 electrode. This includes evidence for statistically significant tuning of the BIC as a function of probe electrode in human subjects. However, results across the three conditions were sometimes not consistent. These discrepancies will be discussed in the light of pitch plasticity versus less plastic brainstem processing.
Management of Children Using Cochlear Implants and Hearing Aids.
ERIC Educational Resources Information Center
Ching, Teresa Y. C.; Psarros, Colleen; Incerti, Paula; Hill, Mandy
2001-01-01
Four case studies identify six factors affecting successful use of a hearing aid with a cochlear implant: duration of hearing aid use prior to implantation, amount of residual hearing in the non-implanted ear, educational and listening demands, cosmetic issues, hearing aid rejection, and extended period of non-use of hearing aid. (Contains…
Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies
Busi, Micol; Rosignoli, Monica; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Martini, Alessandro
2015-01-01
Background. Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. Methods. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Results. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Conclusions. Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central nervous system anomalies represent a negative prognostic factor that is made worse by the concomitant presence of cochlear malformations. Common cavity and stenosis of the internal auditory canal (less than 2 mm) are negative prognostic factors even if brain lesions are absent. PMID:26236732
Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies.
Busi, Micol; Rosignoli, Monica; Castiglione, Alessandro; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Granieri, Enrico; Martini, Alessandro
2015-01-01
Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central nervous system anomalies represent a negative prognostic factor that is made worse by the concomitant presence of cochlear malformations. Common cavity and stenosis of the internal auditory canal (less than 2 mm) are negative prognostic factors even if brain lesions are absent.
Sanderson, Georgina; Ariyaratne, Thathya V; Wyss, Josephine; Looi, Valerie
2014-01-01
Currently, there is a paucity of data concerning the long-term outcomes, educational placement and quality of life of children implanted with hearing devices from large and representative samples of the population. To address this concern, a large, prospective, multicentre, multinational patient-outcomes registry for paediatric recipients of implantable hearing devices was developed. The benefits of this registry, its approach and methodology are described. The Cochlear(™) Paediatric Implanted Recipient Observational Study (Cochlear P-IROS) is a prospective international patient-outcomes registry for children who are implanted in routine clinical practice with one or more hearing devices. The study aims to collect data on patient comorbidities, device use, auditory performance, quality of life and health-related utilities, across different types of implantable hearing devices from a range of manufacturers. Patients will be evaluated with a set of standardised and non-standardised questionnaires prior to initial device activation (baseline) and at six-monthly follow-up intervals up to 24 months and annually thereafter. The Cochlear P-IROS utilises a secure web interface to administer electronic case report forms to clinicians and families of implanted children. The web interface is currently available in five languages: English, Japanese, Korean, Mandarin and Russian. The interface also provides printable versions of the case report forms translated into 22 local languages for collection of data prior to entry online; additional languages may be added, as required. Participation in the Cochlear P-IROS registry is investigator-driven and voluntary. To date, the Cochlear P-IROS has recruited implant clinics across Australia, China, India, Indonesia, Turkey and Vietnam. The registry also aims to recruit multiple clinics in Cuba, Israel, Japan, Malaysia, Singapore, South Africa, South Korea and Russia. The use of a registry such as the Cochlear P-IROS will generate valuable data to support research interests of academics and clinicians around the globe. The data generated will be relevant for a wide range of stakeholders including regulators, payers, providers, policy makers, patients and their families, each with a different perspective for the acceptance and adoption of implantable hearing devices for the treatment of hearing loss.
Infectious complications of pediatric cochlear implants are highly influenced by otitis media.
Vila, Peter M; Ghogomu, Nsangou T; Odom-John, Audrey R; Hullar, Timothy E; Hirose, Keiko
2017-06-01
Determine the incidence of ear infections in cochlear implant patients, evaluate the contribution of otitis media to complications, describe the bacteriology of otitis media in the cochlear implant population, the treatment provided at our center, and the long term outcome. Data collected included age at implantation, history of otitis media or ear tubes, etiology of hearing loss, inner ear anatomy, postoperative infections, time to infection, route of antibiotic administration, and interventions for infections. Categories of infection were acute otitis media, otitis media with effusion, tube otorrhea, meningitis, scalp cellulitis, and infection at the implant site. Middle ear infections were diagnosed in 37% of implanted ears. Extension of middle ear infections into the implant site occurred in 2.8% of all implants (n = 16). Of the 16 infected devices, 10 were successfully treated with antibiotic therapy and did not require explantation. The retained implant group and explanted group both included some middle ear microbes such as Haemophilus influenzae and Streptococcus pneumoniae, as well as skin flora such as Staphylococcus aureus. Otitis media in pediatric cochlear implant patients is a common event and usually does not lead to complications of the cochlear implant. However, when the ear infection spreads to the scalp and the implant site, it is still possible to eliminate the infection using antibiotic therapy, particularly when treatment is directed to the specific organism that is recovered from the infected space and the duration and route of antibiotic treatment is carefully considered. Copyright © 2017 Elsevier B.V. All rights reserved.
The cost and analysis of nonuse of cochlear implants.
Raine, Christopher H; Summerfield, Quentin; Strachan, David R; Martin, Jane M; Totten, Catherine
2008-02-01
Analysis of the cost implications and reasons for nonuse of cochlear implants in an established cochlear implant unit. Clinical data were analyzed retrospectively to construct a table of cochlear implant use over time to identify nonuse and to suggest the reasons for this. Yorkshire Cochlear Implant Service is a tertiary referral center. Three hundred forty consecutively implanted patients from 1990 to 2005. Life table analysis showed that most children used their implant (p = 0.7 during 11 yr). However, 11 of 155 children and 2 of 185 adults became nonusers during the period of study. The 11 children stopped because of age at implant, educational placement, and family support. Two adults stopped because of psychological issues and inability to adapt to the signal. Surgical and implant costs have initial impact, with subsequent years' costs reflecting programming issues and maintenance. When considering nonuse, there are 2 effects: first, no more costs are incurred, and second, no more years of use are accumulated. Thus, nonuse reduces both costs and years. Costs of gaining a year of use as a function of time showed that there was little financial impact from the 11 children nonusers. As a ratio of "no nonuse" and observed "nonuse" in children, the ratio is 1.07 by 13 years of implantation (7%). The adult group was too few to analyze. The nonuse added 7% to the average cost. Retrospective audit identifies that patient selection by a multidisciplinary team is crucial to reducing nonuse.
Sampath Kumar, Raghunandhan; Kameswaran, Mohan
2018-06-01
The overall prevalence of deafness in India is 0.2%, but the prevalence in the southern state of Tamil Nadu is much higher (around 0.6%) because of consanguinity. Especially in India, establishing cochlear implantation as a treatment modality for hearing loss has been a daunting task, but in the last decade, the cochlear implantation program has emerged as an unqualified success in many states, with over 20 000 cochlear implantations done till date. Several states are sponsoring free implants to children under the age of 6 years and below poverty line. Nearly 3000 cochlear implantations have been performed in Tamil Nadu under the Chief Minister's Comprehensive Health Insurance Scheme, with the goal to have a 'deafness free Tamil Nadu' by 2025. This scheme covers nearly 40 million people in rural areas. Valuable lessons have been learnt from this social experiment. One of the cornerstones of this scheme is the method to deliver habilitation via satellite centers in rural areas at the doorstep of the patient. The outcomes in peripheral centers were found to be statistically similar to those in the main center and correlated well with duration of habilitation. Opening up satellite centers for habilitation across the state of Tamil Nadu has greatly helped to improve the attendance and outcomes. The Indian model has been hugely successful and has helped start similar cochlear implantation programs in neighboring countries such as Nepal, Sri Lanka and Bangladesh.
Speech recognition and communication outcomes with cochlear implantation in Usher syndrome type 3.
Pietola, Laura; Aarnisalo, Antti A; Abdel-Rahman, Akram; Västinsalo, Hanna; Isosomppi, Juha; Löppönen, Heikki; Kentala, Erna; Johansson, Reijo; Valtonen, Hannu; Vasama, Juha-Pekka; Sankila, Eeva-Marja; Jero, Jussi
2012-01-01
Usher syndrome Type 3 (USH3) is an autosomal recessive disorder characterized by variable type and degree of progressive sensorineural hearing loss and retinitis pigmentosa. Cochlear implants are widely used among these patients. To evaluate the results and benefits of cochlear implantation in patients with USH3. A nationwide multicenter retrospective review. During the years 1995-2005, in 5 Finnish university hospitals, 19 patients with USH3 received a cochlear implant. Saliva samples were collected to verify the USH3 genotype. Patients answered to 3 questionnaires: Glasgow Benefit Inventory, Glasgow Health Status Inventory, and a self-made questionnaire. Audiological data were collected from patient records. All the patients with USH3 in the study were homozygous for the Finnish major mutation (p.Y176X). Either they had severe sensorineural hearing loss or they were profoundly deaf. The mean preoperative hearing level (pure-tone average, 0.5-4 kHz) was 110 ± 8 dB hearing loss (HL) and the mean aided hearing level was 58 ± 11 dB HL. The postoperative hearing level (34 ± 9 dB HL) and word recognition scores were significantly better than before surgery. According to the Glasgow Benefit Inventory scores and Glasgow Health Status Inventory data related to hearing, the cochlear implantation was beneficial to patients with USH3. Cochlear implantation is beneficial to patients with USH3, and patients learn to use the implant without assistance.
Cochlear Implantation, Enhancements, Transhumanism and Posthumanism: Some Human Questions.
Lee, Joseph
2016-02-01
Biomedical engineering technologies such as brain-machine interfaces and neuroprosthetics are advancements which assist human beings in varied ways. There are exciting yet speculative visions of how the neurosciences and bioengineering may influence human nature. However, these could be preparing a possible pathway towards an enhanced and even posthuman future. This article seeks to investigate several ethical themes and wider questions of enhancement, transhumanism and posthumanism. Four themes of interest are: autonomy, identity, futures, and community. Three larger questions can be asked: will everyone be enhanced? Will we be "human" if we are not, one day, transhuman? Should we be enhanced or not? The article proceeds by concentrating on a widespread and sometimes controversial application: the cochlear implant, an auditory prosthesis implanted into Deaf patients. Cochlear implantation and its reception in both the deaf and hearing communities have a distinctive moral discourse, which can offer surprising insights. The paper begins with several points about the enhancement of human beings, transhumanism's reach beyond the human, and posthuman aspirations. Next it focuses on cochlear implants on two sides. Firstly, a shorter consideration of what technologies may do to humans in a transhumanist world. Secondly, a deeper analysis of cochlear implantation's unique socio-political movement, its ethical explanations and cultural experiences linked with pediatric cochlear implantation-and how those wary of being thrust towards posthumanism could marshal such ideas by analogy. As transhumanism approaches, the issues and questions merit continuing intense analysis.
Song, Mee Hyun; Bae, Mi Ran; Kim, Hee Nam; Lee, Won-Sang; Yang, Won Sun; Choi, Jae Young
2010-08-01
Cochlear implantation in patients with narrow internal auditory canal (IAC) can result in variable outcomes; however, preoperative evaluations have limitations in accurately predicting outcomes. In this study, we analyzed the outcomes of cochlear implantation in patients with narrow IAC and correlated the intracochlear electrically evoked auditory brainstem response (EABR) findings to postoperative performance to determine the prognostic significance of intracochlear EABR. Retrospective case series at a tertiary hospital. Thirteen profoundly deaf patients with narrow IAC who received cochlear implantation from 2002 to 2008 were included in this study. Postoperative performance was evaluated after at least 12 months of follow-up, and postoperative intracochlear EABR was measured to determine its correlation with outcome. The clinical significance of electrically evoked compound action potential (ECAP) was also analyzed. Patients with narrow IAC showed postoperative auditory performances ranging from CAP 0 to 4 after cochlear implantation. Intracochlear EABR measured postoperatively demonstrated prognostic value in the prediction of long-term outcomes, whereas ECAP measurements failed to show a significant correlation with outcome. Consistent with the advantages of intracochlear EABR over extracochlear EABR, this study demonstrates that intracochlear EABR has prognostic significance in predicting long-term outcomes in patients with narrow IAC. Intracochlear EABR measured either intraoperatively or in the early postoperative period may play an important role in deciding whether to continue with auditory rehabilitation using a cochlear implant or to switch to an auditory brainstem implant so as not to miss the optimal timing for language development.
... tinnitus in a significant number of study volunteers. Cochlear implants are sometimes used in people who have tinnitus along with severe hearing loss. A cochlear implant bypasses the damaged portion of the inner ...
Developmental Effects of Family Environment on Outcomes in Pediatric Cochlear Implant Recipients
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.
2012-01-01
Objective To examine and compare the family environment of preschool- and school-age children with cochlear implants and assess its influence on children’s executive function and spoken language skills. Study Design Retrospective between-subjects design. Setting Outpatient research laboratory. Patients Prelingually deaf children with cochlear implants and no additional disabilities, and their families. Intervention(s) Cochlear implantation and speech-language therapy. Main Outcome Measures Parents completed the Family Environment Scale and the Behavior Rating Inventory of Executive Function (or the preschool version). Children were tested using the Peabody Picture Vocabulary Test-4 and either the Preschool Language Scales-4 or the Clinical Evaluation of Language Fundamentals–4. Results The family environments of children with cochlear implants differed from normative data obtained from hearing children, but average scores were within one standard deviation of norms on all subscales. Families of school-age children reported higher levels of control than those of preschool-age children. Preschool-age children had fewer problems with emotional control when families reported higher levels of support and lower levels of conflict. School-age children had fewer problems with inhibition but more problems with shifting of attention when families reported lower levels of conflict. School-age children’s receptive vocabularies were enhanced by families with lower levels of control and higher levels of organization. Conclusions Family environment and its relation to language skills and executive function development differed across the age groups in this sample of children with cochlear implants. Because family dynamics is one developmental/environmental factor that can be altered with therapy and education, the present results have important clinical implications for family-based interventions for deaf children with cochlear implants. PMID:23151776
Development and evaluation of the Nurotron 26-electrode cochlear implant system.
Zeng, Fan-Gang; Rebscher, Stephen J; Fu, Qian-Jie; Chen, Hongbin; Sun, Xiaoan; Yin, Li; Ping, Lichuan; Feng, Haihong; Yang, Shiming; Gong, Shusheng; Yang, Beibei; Kang, Hou-Yong; Gao, Na; Chi, Fanglu
2015-04-01
Although the cochlear implant has been widely acknowledged as the most successful neural prosthesis, only a fraction of hearing-impaired people who can potentially benefit from a cochlear implant have actually received one due to its limited awareness, accessibility, and affordability. To help overcome these limitations, a 26-electrode cochlear implant has been developed to receive China's Food and Drug Administration (CFDA) approval in 2011 and Conformité Européenne (CE) Marking in 2012. The present article describes design philosophy, system specification, and technical verification of the Nurotron device, which includes advanced digital signal processing and 4 current sources with multiple amplitude resolutions that not only are compatible with perceptual capability but also allow interleaved or simultaneous stimulation. The article also presents 3-year longitudinal evaluation data from 60 human subjects who have received the Nurotron device. The objective measures show that electrode impedance decreased within the first month of device use, but was stable until a slight increase at the end of two years. The subjective loudness measures show that electric stimulation threshold was stable while the maximal comfort level increased over the 3 years. Mandarin sentence recognition increased from the pre-surgical 0%-correct score to a plateau of about 80% correct with 6-month use of the device. Both indirect and direct comparisons indicate indistinguishable performance differences between the Nurotron system and other commercially available devices. The present 26-electrode cochlear implant has already helped to lower the price of cochlear implantation in China and will likely contribute to increased cochlear implant access and success in the rest of the world. This article is part of a Special Issue entitled
Tinnitus and Sleep Difficulties After Cochlear Implantation.
Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T
To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p < 0.001). Self-reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p < 0.001). The prevalence of sleep difficulties was not related to tinnitus persistence (p = 0.28) or the extent to which tinnitus was distressing (p = 0.55). The lack of association between tinnitus persistence and sleep difficulties is compatible with the notion that tinnitus is suppressed in implant users primarily during active electrical stimulation and may return when the implant is switched off at night time. This explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention where the primary aim is to alleviate sleep difficulties.
Implications of Minimizing Trauma During Conventional Cochlear Implantation
Carlson, Matthew L.; Driscoll, Colin L. W.; Gifford, René H.; Service, Geoffrey J.; Tombers, Nicole M.; Hughes-Borst, Becky J.; Neff, Brian A.; Beatty, Charles W.
2014-01-01
Objective To describe the relationship between implantation-associated trauma and postoperative speech perception scores among adult and pediatric patients undergoing cochlear implantation using conventional length electrodes and minimally traumatic surgical techniques. Study Design Retrospective chart review (2002–2010). Setting Tertiary academic referral center. Patients All subjects with significant preoperative low-frequency hearing (≤70 dB HL at 250 Hz) who underwent cochlear implantation with a newer generation implant electrode (Nucleus Contour Advance, Advanced Bionics HR90K [1J and Helix], and Med El Sonata standard H array) were reviewed. Intervention(s) Preimplant and postimplant audiometric thresholds and speech recognition scores were recorded using the electronic medical record. Main Outcome Measure(s) Postimplantation pure tone threshold shifts were used as a surrogate measure for extent of intracochlear injury and correlated with postoperative speech perception scores. Results Between 2002 and 2010, 703 cochlear implant (CI) operations were performed. Data from 126 implants were included in the analysis. The mean preoperative low-frequency pure-tone average was 55.4 dB HL. Hearing preservation was observed in 55% of patients. Patients with hearing preservation were found to have significantly higher postoperative speech perception performance in the cochlear implantation-only condition than those who lost all residual hearing. Conclusion Conservation of acoustic hearing after conventional length cochlear implantation is unpredictable but remains a realistic goal. The combination of improved technology and refined surgical technique may allow for conservation of some residual hearing in more than 50% of patients. Germane to the conventional length CI recipient with substantial hearing loss, minimizing trauma allows for improved speech perception in the electric condition. These findings support the use of minimally traumatic techniques in all CI recipients, even those destined for electric-only stimulation. PMID:21659922
Barriers to pediatric cochlear implantation: A parental survey.
Yang, Charles Q; Reilly, Brian K; Preciado, Diego A
2018-01-01
This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.
Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation.
Hunter, Jacob B; Gifford, René H; Wanna, George B; Labadie, Robert F; Bennett, Marc L; Haynes, David S; Rivas, Alejandro
2016-03-01
To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. Tertiary academic center. Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. Cochlear implantation. Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500 Hz) was 20.2 dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.
Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
Vargas, Jose Luis; Sainz, Manuel; Roldan, Cristina; de la Torre, Angel
2012-01-01
Objectives The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. Methods Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada, Spain. Hearing loss etiology and progression characteristics varied across subjects. Results The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. Conclusion We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor. PMID:23205223
Quittner, Alexandra L; Cejas, Ivette; Wang, Nae-Yuh; Niparko, John K; Barker, David H
2016-01-01
In the largest, longitudinal study of young, deaf children before and three years after cochlear implantation, we compared symbolic play and novel noun learning to age-matched hearing peers. Participants were 180 children from six cochlear implant centers and 96 hearing children. Symbolic play was measured during five minutes of videotaped, structured solitary play. Play was coded as "symbolic" if the child used substitution (e.g., a wooden block as a bed). Novel noun learning was measured in 10 trials using a novel object and a distractor. Cochlear implant vs. normal hearing children were delayed in their use of symbolic play, however, those implanted before vs. after age two performed significantly better. Children with cochlear implants were also delayed in novel noun learning (median delay 1.54 years), with minimal evidence of catch-up growth. Quality of parent-child interactions was positively related to performance on the novel noun learning, but not symbolic play task. Early implantation was beneficial for both achievement of symbolic play and novel noun learning. Further, maternal sensitivity and linguistic stimulation by parents positively affected noun learning skills, although children with cochlear implants still lagged in comparison to hearing peers.
Quittner, Alexandra L.; Cejas, Ivette; Wang, Nae-Yuh; Niparko, John K.; Barker, David H.
2016-01-01
In the largest, longitudinal study of young, deaf children before and three years after cochlear implantation, we compared symbolic play and novel noun learning to age-matched hearing peers. Participants were 180 children from six cochlear implant centers and 96 hearing children. Symbolic play was measured during five minutes of videotaped, structured solitary play. Play was coded as "symbolic" if the child used substitution (e.g., a wooden block as a bed). Novel noun learning was measured in 10 trials using a novel object and a distractor. Cochlear implant vs. normal hearing children were delayed in their use of symbolic play, however, those implanted before vs. after age two performed significantly better. Children with cochlear implants were also delayed in novel noun learning (median delay 1.54 years), with minimal evidence of catch-up growth. Quality of parent-child interactions was positively related to performance on the novel noun learning, but not symbolic play task. Early implantation was beneficial for both achievement of symbolic play and novel noun learning. Further, maternal sensitivity and linguistic stimulation by parents positively affected noun learning skills, although children with cochlear implants still lagged in comparison to hearing peers. PMID:27228032
Scarbel, Lucie; Beautemps, Denis; Schwartz, Jean-Luc; Sato, Marc
2017-07-01
Speech communication can be viewed as an interactive process involving a functional coupling between sensory and motor systems. One striking example comes from phonetic convergence, when speakers automatically tend to mimic their interlocutor's speech during communicative interaction. The goal of this study was to investigate sensory-motor linkage in speech production in postlingually deaf cochlear implanted participants and normal hearing elderly adults through phonetic convergence and imitation. To this aim, two vowel production tasks, with or without instruction to imitate an acoustic vowel, were proposed to three groups of young adults with normal hearing, elderly adults with normal hearing and post-lingually deaf cochlear-implanted patients. Measure of the deviation of each participant's f 0 from their own mean f 0 was measured to evaluate the ability to converge to each acoustic target. showed that cochlear-implanted participants have the ability to converge to an acoustic target, both intentionally and unintentionally, albeit with a lower degree than young and elderly participants with normal hearing. By providing evidence for phonetic convergence and speech imitation, these results suggest that, as in young adults, perceptuo-motor relationships are efficient in elderly adults with normal hearing and that cochlear-implanted adults recovered significant perceptuo-motor abilities following cochlear implantation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Chang, Pamara F
2017-08-01
To understand the dynamic experiences of parents undergoing the decision-making process regarding cochlear implants for their child(ren). Thirty-three parents of d/Deaf children participated in semi-structured interviews. Interviews were digitally recorded, transcribed, and coded using iterative and thematic coding. The results from this study reveal four salient topics related to parents' decision-making process regarding cochlear implantation: 1) factors parents considered when making the decision to get the cochlear implant for their child (e.g., desire to acculturate child into one community), 2) the extent to which parents' communities influence their decision-making (e.g., norms), 3) information sources parents seek and value when decision-making (e.g., parents value other parent's experiences the most compared to medical or online sources), and 4) personal experiences with stigma affecting their decision to not get the cochlear implant for their child. This study provides insights into values and perspectives that can be utilized to improve informed decision-making, when making risky medical decisions with long-term implications. With thorough information provisions, delineation of addressing parents' concerns and encompassing all aspects of the decision (i.e., medical, social and cultural), health professional teams could reduce the uncertainty and anxiety for parents in this decision-making process for cochlear implantation. Copyright © 2017 Elsevier B.V. All rights reserved.
Ou, Henry; Cleary, Patricia; Sie, Kathleen
2010-10-01
To demonstrate the use of a state-maintained database (CHILD Profile) to monitor immunization status of pediatric cochlear implant recipients, and to assess compliance with current vaccination recommendations for cochlear implant users managed at Seattle Children's Hospital. Cross-sectional study. Tertiary academic pediatric hospital. Subjects were 260 patients with cochlear implants managed at Seattle Children's Hospital between July 1, 1995, and May 1, 2008. Patients were stratified by age groups (0-2 years, 2-5 years, 5-10 years, > 10 years). Using a statewide children's immunization registry (CHILD Profile), subjects were assessed with regard to their immunization status for Haemophilus influenzae type B vaccination (HiB), 7-valent pneumococcal conjugate vaccination (PCV-7), and 23-valent pneumococcal polysaccharide vaccine (PPV-23). Two hundred twenty-five of 260 subjects (87%) were registered in CHILD Profile; 126 of 225 (56%) were up to date with CDC recommendations for patients with cochlear implants. PPV-23 was the vaccination most likely to be incomplete. Age was predictive of immunization status only with HiB vaccination. A statewide immunization registry can be used to monitor the immunization status of cochlear implant recipients. Subjects were significantly more likely to be incomplete for PPV-23 than for either PCV-7 or HiB vaccinations. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.
Hashemi, Seyed Basir; Monshizadeh, Leila
2012-06-01
Before the introduction of cochlear implant (CI) in 1980, hearing aids were the only means by which profoundly deaf children had access to auditory stimuli. Nowadays, CI is firmly established as effective option in speech and language rehabilitation of deaf children, but much of the literature regarding outcomes for children after CI are focused on development of speech and less is known about language acquisition. So, the main aim of this study is the evaluation of verbal intelligence quotient (IQ) of cochlear implanted children in comparison with normal children. 30 cochlear implanted and 30 normal hearing children with similar socio-economic level at the same age were compared by a revised version (in Persian) of WISC test (Wechsler, 1991). Then the data were analyzed through SPSS software 16. In spite of the fact that cochlear implanted children did well in different parameters of WISC test, the average scores of this group was less than normal hearing children. But in similarities (one of the parameters of WISC test) 2 group's performance was approximately the same. CI plays an important role in development of verbal IQ and language acquisition of deaf children. Different researches indicate that most of the cochlear implanted children show less language delay during the time. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Chung, King; Nelson, Lance; Teske, Melissa
2012-09-01
The purpose of this study was to investigate whether a multichannel adaptive directional microphone and a modulation-based noise reduction algorithm could enhance cochlear implant performance in reverberant noise fields. A hearing aid was modified to output electrical signals (ePreprocessor) and a cochlear implant speech processor was modified to receive electrical signals (eProcessor). The ePreprocessor was programmed to flat frequency response and linear amplification. Cochlear implant listeners wore the ePreprocessor-eProcessor system in three reverberant noise fields: 1) one noise source with variable locations; 2) three noise sources with variable locations; and 3) eight evenly spaced noise sources from 0° to 360°. Listeners' speech recognition scores were tested when the ePreprocessor was programmed to omnidirectional microphone (OMNI), omnidirectional microphone plus noise reduction algorithm (OMNI + NR), and adaptive directional microphone plus noise reduction algorithm (ADM + NR). They were also tested with their own cochlear implant speech processor (CI_OMNI) in the three noise fields. Additionally, listeners rated overall sound quality preferences on recordings made in the noise fields. Results indicated that ADM+NR produced the highest speech recognition scores and the most preferable rating in all noise fields. Factors requiring attention in the hearing aid-cochlear implant integration process are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.
Outcomes and special considerations of cochlear implantation in waardenburg syndrome.
Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke
2011-08-01
The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.
Patients reported outcome post-cochlear implantation: how severe is their dizziness?
Zawawi, Faisal; Alobaid, Faisal; Leroux, Tony; Zeitouni, Anthony G
2014-01-01
The reported prevalence of vestibular dysfunction after cochlear implantation (CI) is varies between different scientific papers. The aim of this study is to determine the reported post-implantation outcome in terms of dizziness, and to measure its impact on quality of life using the Dizziness handicap inventory (DHI). This was a prospective questionnaire based study of postoperative cochlear implant patients. The questionnaire assessed the type and onset of dizziness in addition to the DHI. 122 patients were recruited in this study, which is the largest sample size in the literature reported so far. Dizziness was evident in 45.9% of the population post-CI and in 27% pre-CI. The commonest subtype of the dizziness was unsteadiness followed by lightheadedness. The dizziness was mild in most of the patients. Although mild, dizziness is a common complaint post-cochlear implantation. An understanding of symptoms helps counsel patients preoperatively.
Profound hearing loss associated with hydrocodone/acetaminophen abuse.
Friedman, R A; House, J W; Luxford, W M; Gherini, S; Mills, D
2000-03-01
To describe profound hearing loss associated with hydrocodone overuse and the successful rehabilitation of these patients with cochlear implantation. Retrospective review. A tertiary otologic referral center. Twelve patients with rapidly progressive hearing loss and a concurrent history of hydrocodone overuse. Comprehensive medical histories, physical findings, audiometric tests, and, in those patients undergoing cochlear implantation, postimplantation performance data were reviewed. Clinical characteristics of hydrocodone-related hearing loss and open set word and sentence performance in those patients undergoing cochlear implantation. Hydrocodone overuse was associated with rapidly progressive sensorineural hearing loss in 12 patients. In four patients the initial presentation was unilateral, and two of the patients experienced vestibular symptoms. None of the 12 patients experienced improved thresholds after high-dose prednisone. Seven of the eight patients undergoing cochlear implantation have demonstrated early success with their devices. Hydrocodone is frequently prescribed in combination with acetaminophen for the relief of pain and has a side effects profile similar to other medications in its class. Although not described previously, overuse or abuse can be associated with a rapidly progressive sensorineural hearing loss. These patients can be successfully rehabilitated with cochlear implantation.
Challenges in Improving Cochlear Implant Performance and Accessibility.
Zeng, Fan-Gang
2017-08-01
Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.
Sorkin, Donna L
2013-03-01
Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.
Prevention and management of vascular complications in middle ear and cochlear implant surgery.
Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo
2017-11-01
The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.
Future technology in cochlear implants: assessing the benefit.
Briggs, Robert J S
2011-05-01
It has been over 50 years since Djourno and Eyries first attempted electric stimulation in a patient with deafness. Over this time, the Cochlear Implant (CI) has become not only remarkably successful, but increasingly complex. Although the basic components of the system still comprise an implanted receiver stimulator and electrode, externally worn speech processor, microphone, control system, and power source, there are now several alternative designs of these components with different attributes that can be variably combined to meet the needs of specific patient groups. Development by the manufacturers has been driven both by these various patient needs, and also by the desire to achieve technological superiority, or at least differentiation, ultimately in pursuit of market share. Assessment of benefit is the responsibility of clinicians. It is incumbent on both industry and clinicians to ensure appropriate, safe, and affordable introduction of new technology. For example, experience with the totally implanted cochlear implant (TIKI) has demonstrated that quality of hearing is the over-riding consideration for CI users. To date, improved hearing outcomes have been achieved by improvements in: speech processing strategies; microphone technology; pre-processing strategies; electrode placement; bilateral implantation; use of a hearing aid in the opposite ear (bimodal stimulation); and the combination of electric and acoustic stimulation in the same ear. The resulting expansion of CI candidacy, with more residual hearing, further improves the outcomes achieved. Largely facilitated by advances in electronic capability and computerization, it can be expected that these improvements will continue. However, marked variability of results still occurs and we cannot assure any individual patient of their outcome. Realistic goals for implementation of new technology include: improved hearing in noise and music perception; effective invisible hearing (no external apparatus); automated fitting; and reduction in outcome variability. This paper provides examples of relevant potential future technologies that can be applied to reach these goals. In the quest for better outcomes, future technology must deliver improved reliability and usability for both clinicians and recipients that does not compromise safety and is affordable. One of the challenges related to the introduction of new technologies is the 'classification' of CI systems and the framework under which sufficient change and increased benefit can be demonstrated to establish a claim of 'new generation CI' and hence increased reimbursement from third-party payers. Significant improvements in hearing outcomes and quality of life associated with CI design changes are difficult to measure, particularly when there is such dramatic benefit from the intervention of cochlear implantation from the individual's perspective. Manufacturers and clinicians need to be objective and undertake appropriate safety studies and long-term and multi-centre clinical trials to ensure that the introduction of new technology is both safe and effective and supported by health systems worldwide.
Chen, Yuan; Wong, Lena L N; Zhu, Shufeng; Xi, Xin
2017-01-01
China has the largest population of children with hearing impairments and cochlear implantation is gaining popularity there. However, the vocabulary development in this population is largely unexplored. This study examined early vocabulary outcomes, factors influencing early vocabulary development and the relationship between speech perception and vocabulary development in Mandarin-speaking children during the first year of cochlear implant use. A battery of vocabulary tests was administered to 80 children before implantation and 3, 6, and 12 months after implantation. Demographic information was obtained to evaluate their relationships with vocabulary outcomes. The Mandarin-speaking children, who received their cochlear implants before 3 years of age, developed vocabulary at a rate faster than that of their same-aged peers with normal hearing. Better pre-implant hearing levels, younger age at implantation, and higher maternal education level contributed to the early vocabulary development. The trajectories of speech perception development highly correlated with those of vocabulary development during 3 to 12 months of CI use. and Implications: These findings imply that the vocabulary development of children implanted before 3 years of age may catch up with that of their hearing peers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Development of speech perception and production in children with cochlear implants.
Kishon-Rabin, Liat; Taitelbaum, Riki; Muchnik, Chava; Gehtler, Inbal; Kronenberg, Jona; Hildesheimer, Minka
2002-05-01
The purpose of the present study was twofold: 1) to compare the hierarchy of perceived and produced significant speech pattern contrasts in children with cochlear implants, and 2) to compare this hierarchy to developmental data of children with normal hearing. The subjects included 35 prelingual hearing-impaired children with multichannel cochlear implants. The test materials were the Hebrew Speech Pattern Contrast (HeSPAC) test and the Hebrew Picture Speech Pattern Contrast (HePiSPAC) test for older and younger children, respectively. The results show that 1) auditory speech perception performance of children with cochlear implants reaches an asymptote at 76% (after correction for guessing) between 4 and 6 years of implant use; 2) all implant users perceived vowel place extremely well immediately after implantation; 3) most implanted children perceived initial voicing at chance level until 2 to 3 years after implantation, after which scores improved by 60% to 70% with implant use; 4) the hierarchy of phonetic-feature production paralleled that of perception: vowels first, voicing last, and manner and place of articulation in between; and 5) the hierarchy in speech pattern contrast perception and production was similar between the implanted and the normal-hearing children, with the exception of the vowels (possibly because of the interaction between the specific information provided by the implant device and the acoustics of the Hebrew language). The data reported here contribute to our current knowledge about the development of phonological contrasts in children who were deprived of sound in the first few years of their lives and then developed phonetic representations via cochlear implants. The data also provide additional insight into the interrelated skills of speech perception and production.
Kang, Robert; Nimmons, Grace Liu; Drennan, Ward; Longnion, Jeff; Ruffin, Chad; Nie, Kaibao; Won, Jong Ho; Worman, Tina; Yueh, Bevan; Rubinstein, Jay
2009-08-01
Assessment of cochlear implant outcomes centers around speech discrimination. Despite dramatic improvements in speech perception, music perception remains a challenge for most cochlear implant users. No standardized test exists to quantify music perception in a clinically practical manner. This study presents the University of Washington Clinical Assessment of Music Perception (CAMP) test as a reliable and valid music perception test for English-speaking, adult cochlear implant users. Forty-two cochlear implant subjects were recruited from the University of Washington Medical Center cochlear implant program and referred by two implant manufacturers. Ten normal-hearing volunteers were drawn from the University of Washington Medical Center and associated campuses. A computer-driven, self-administered test was developed to examine three specific aspects of music perception: pitch direction discrimination, melody recognition, and timbre recognition. The pitch subtest used an adaptive procedure to determine just-noticeable differences for complex tone pitch direction discrimination within the range of 1 to 12 semitones. The melody and timbre subtests assessed recognition of 12 commonly known melodies played with complex tones in an isochronous manner and eight musical instruments playing an identical five-note sequence, respectively. Testing was repeated for cochlear implant subjects to evaluate test-retest reliability. Normal-hearing volunteers were also tested to demonstrate differences in performance in the two populations. For cochlear implant subjects, pitch direction discrimination just-noticeable differences ranged from 1 to 8.0 semitones (Mean = 3.0, SD = 2.3). Melody and timbre recognition ranged from 0 to 94.4% correct (mean = 25.1, SD = 22.2) and 20.8 to 87.5% (mean = 45.3, SD = 16.2), respectively. Each subtest significantly correlated at least moderately with both Consonant-Nucleus-Consonant (CNC) word recognition scores and spondee recognition thresholds in steady state noise and two-talker babble. Intraclass coefficients demonstrating test-retest correlations for pitch, melody, and timbre were 0.85, 0.92, and 0.69, respectively. Normal-hearing volunteers had a mean pitch direction discrimination threshold of 1.0 semitone, the smallest interval tested, and mean melody and timbre recognition scores of 87.5 and 94.2%, respectively. The CAMP test discriminates a wide range of music perceptual ability in cochlear implant users. Moderate correlations were seen between music test results and both Consonant-Nucleus-Consonant word recognition scores and spondee recognition thresholds in background noise. Test-retest reliability was moderate to strong. The CAMP test provides a reliable and valid metric for a clinically practical, standardized evaluation of music perception in adult cochlear implant users.
Music Therapy for Preschool Cochlear Implant Recipients
Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya
2010-01-01
This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691
Some considerations concerning cochlear implantation in IFACF-ORL
Hainarosie, M; Zainea, V; Serban, S; Georgescu, MG; Hainarosie, R; Marinescu, A; Georgescu, G
2014-01-01
The article analyzes the patients who have received a cochlear implant at “Prof. Dr. Dorin Hociota” Institute of Phonoaudiology and Functional ENT Surgery, Bucharest, over a period of 13 years, from the beginning of this program in the year 2000. It presents the types of devices used, the particularities of the patients, the surgical techniques and the outcome, critically analyzing the complications encountered. The authors’ comments on the selection of patient protocol, surgical intraoperative challenges and cochlear implant technologies and capabilities are presented. PMID:25870683
Technological Innovations and Intervention Practices for Children with Cochlear Implants.
ERIC Educational Resources Information Center
Ertmer, David J.
2002-01-01
This epilogue to a forum on children with hearing impairments who have cochlear implants discusses innovation in implant technology and considers intervention issues. Key factors influencing outcomes are discussed, including educational programming, amount and length of communication intervention, and the targeting of both developmental and…
Benefits and Risks of Cochlear Implants
... The cochlear implant stimulates the nerves directly with electrical currents. Although this stimulation appears to be safe, the long term effect of these electrical currents on the nerves is unknown. May not ...
Ortmann, Magdalene; Zwitserlood, Pienie; Knief, Arne; Baare, Johanna; Brinkheetker, Stephanie; am Zehnhoff-Dinnesen, Antoinette; Dobel, Christian
2017-01-01
Cochlear implants provide individuals who are deaf with access to speech. Although substantial advancements have been made by novel technologies, there still is high variability in language development during childhood, depending on adaptation and neural plasticity. These factors have often been investigated in the auditory domain, with the mismatch negativity as an index for sensory and phonological processing. Several studies have demonstrated that the MMN is an electrophysiological correlate for hearing improvement with cochlear implants. In this study, two groups of cochlear implant users, both with very good basic hearing abilities but with non-overlapping speech performance (very good or very poor speech performance), were matched according to device experience and age at implantation. We tested the perception of phonemes in the context of specific other phonemes from which they were very hard to discriminate (e.g., the vowels in /bu/ vs. /bo/). The most difficult pair was individually determined for each participant. Using behavioral measures, both cochlear implants groups performed worse than matched controls, and the good performers performed better than the poor performers. Cochlear implant groups and controls did not differ during time intervals typically used for the mismatch negativity, but earlier: source analyses revealed increased activity in the region of the right supramarginal gyrus (220–260 ms) in good performers. Poor performers showed increased activity in the left occipital cortex (220–290 ms), which may be an index for cross-modal perception. The time course and the neural generators differ from data from our earlier studies, in which the same phonemes were assessed in an easy-to-discriminate context. The results demonstrate that the groups used different language processing strategies, depending on the success of language development and the particular language context. Overall, our data emphasize the role of neural plasticity and use of adaptive strategies for successful language development with cochlear implants. PMID:28056017
A cochlear implant fabricated using a bulk silicon-surface micromachining process
NASA Astrophysics Data System (ADS)
Bell, Tracy Elizabeth
1999-11-01
This dissertation presents the design and fabrication of two generations of a silicon microelectrode array for use in a cochlear implant. A cochlear implant is a device that is inserted into the inner ear and uses electrical stimulation to provide sound sensations to the profoundly deaf. The first-generation silicon cochlear implant is a passive device fabricated using silicon microprobe technology developed at the University of Michigan. It contains twenty-two iridium oxide (IrO) stimulating sites that are 250 mum in diameter and spaced at 750 mum intervals. In-vivo recordings were made in guinea pig auditory cortex in response to electrical stimulation with this device, verifying its ability to electrically evoke an auditory response. Auditory thresholds as low as 78 muA were recorded. The second-generation implant is a thirty-two site, four-channel device with on-chip CMOS site-selection circuitry and integrated position sensing. It was fabricated using a novel bulk silicon surface micromachining process which was developed as a part of this dissertation work. While the use of semiconductor technology offers many advantages in fabricating cochlear implants over the methods currently used, it was felt that even further advantages could be gained by developing a new micromachining process which would allow circuitry to be distributed along the full length of the cochlear implant substrate. The new process uses electropolishing of an n+ bulk silicon sacrificial layer to undercut and release n- epitaxial silicon structures from the wafer. An extremely abrupt etch-stop between the n+ and n- silicon is obtained, with no electropolishing taking place in the n-type silicon that is doped lower than 1 x 1017 cm-3 in concentration. Lateral electropolishing rates of up to 50 mum/min were measured using this technique, allowing one millimeter-wide structures to be fully undercut in as little as 10 minutes. The new micromachining process was integrated with a standard p-well CMOS integrated circuit process to fabricate the second-generation active silicon cochlear implants.
Oryadi-Zanjani, Mohammad Majid; Vahab, Maryam; Rahimi, Zahra; Mayahi, Anis
2017-02-01
It is important for clinician such as speech-language pathologists and audiologists to develop more efficient procedures to assess the development of auditory, speech and language skills in children using hearing aid and/or cochlear implant compared to their peers with normal hearing. So, the aim of study was the comparison of the performance of 5-to-7-year-old Persian-language children with and without hearing loss in visual-only, auditory-only, and audiovisual presentation of sentence repetition task. The research was administered as a cross-sectional study. The sample size was 92 Persian 5-7 year old children including: 60 with normal hearing and 32 with hearing loss. The children with hearing loss were recruited from Soroush rehabilitation center for Persian-language children with hearing loss in Shiraz, Iran, through consecutive sampling method. All the children had unilateral cochlear implant or bilateral hearing aid. The assessment tool was the Sentence Repetition Test. The study included three computer-based experiments including visual-only, auditory-only, and audiovisual. The scores were compared within and among the three groups through statistical tests in α = 0.05. The score of sentence repetition task between V-only, A-only, and AV presentation was significantly different in the three groups; in other words, the highest to lowest scores belonged respectively to audiovisual, auditory-only, and visual-only format in the children with normal hearing (P < 0.01), cochlear implant (P < 0.01), and hearing aid (P < 0.01). In addition, there was no significant correlationship between the visual-only and audiovisual sentence repetition scores in all the 5-to-7-year-old children (r = 0.179, n = 92, P = 0.088), but audiovisual sentence repetition scores were found to be strongly correlated with auditory-only scores in all the 5-to-7-year-old children (r = 0.943, n = 92, P = 0.000). According to the study's findings, audiovisual integration occurs in the 5-to-7-year-old Persian children using hearing aid or cochlear implant during sentence repetition similar to their peers with normal hearing. Therefore, it is recommended that audiovisual sentence repetition should be used as a clinical criterion for auditory development in Persian-language children with hearing loss. Copyright © 2016. Published by Elsevier B.V.
Goupell, Matthew J
2015-03-01
Bilateral cochlear implant (CI) listeners can perform binaural tasks, but they are typically worse than normal-hearing (NH) listeners. To understand why this difference occurs and the mechanisms involved in processing dynamic binaural differences, interaural envelope correlation change discrimination sensitivity was measured in real and simulated CI users. In experiment 1, 11 CI (eight late deafened, three early deafened) and eight NH listeners were tested in an envelope correlation change discrimination task. Just noticeable differences (JNDs) were best for a matched place-of-stimulation and increased for an increasing mismatch. In experiment 2, attempts at intracranially centering stimuli did not produce lower JNDs. In experiment 3, the percentage of correct identifications of antiphasic carrier pulse trains modulated by correlated envelopes was measured as a function of mismatch and pulse rate. Sensitivity decreased for increasing mismatch and increasing pulse rate. The experiments led to two conclusions. First, envelope correlation change discrimination necessitates place-of-stimulation matched inputs. However, it is unclear if previous experience with acoustic hearing is necessary for envelope correlation change discrimination. Second, NH listeners presented with CI simulations demonstrated better performance than real CI listeners. If the simulations are realistic representations of electrical stimuli, real CI listeners appear to have difficulty processing interaural information in modulated signals.
Zeitooni, Mehrnaz; Mäki-Torkko, Elina; Stenfelt, Stefan
The purpose of this study is to evaluate binaural hearing ability in adults with normal hearing when bone conduction (BC) stimulation is bilaterally applied at the bone conduction hearing aid (BCHA) implant position as well as at the audiometric position on the mastoid. The results with BC stimulation are compared with bilateral air conduction (AC) stimulation through earphones. Binaural hearing ability is investigated with tests of spatial release from masking and binaural intelligibility level difference using sentence material, binaural masking level difference with tonal chirp stimulation, and precedence effect using noise stimulus. In all tests, results with bilateral BC stimulation at the BCHA position illustrate an ability to extract binaural cues similar to BC stimulation at the mastoid position. The binaural benefit is overall greater with AC stimulation than BC stimulation at both positions. The binaural benefit for BC stimulation at the mastoid and BCHA position is approximately half in terms of decibels compared with AC stimulation in the speech based tests (spatial release from masking and binaural intelligibility level difference). For binaural masking level difference, the binaural benefit for the two BC positions with chirp signal phase inversion is approximately twice the benefit with inverted phase of the noise. The precedence effect results with BC stimulation at the mastoid and BCHA position are similar for low frequency noise stimulation but differ with high-frequency noise stimulation. The results confirm that binaural hearing processing with bilateral BC stimulation at the mastoid position is also present at the BCHA implant position. This indicates the ability for binaural hearing in patients with good cochlear function when using bilateral BCHAs.
Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P
2018-03-01
Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p < 0.001). There was strong agreement between standard manual testing and remote automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR120 177.0 μV, SD 11.57; p value < 0.001). These preliminary data demonstrate that intraoperative cochlear implant device testing using a remote automated system is feasible. This system may be useful for cochlear implant programs with limited audiology support or for programs looking to streamline intraoperative device testing protocols. Future studies with larger patient enrollment are required to validate these promising, but preliminary, findings.
Coelho, Daniel H; Hammerschlag, Paul E; Bat-Chava, Yael; Kohan, Darius
2009-06-01
The Cochlear Implant Function Index (CIFI) is created to assess adult cochlear implant (CI) auditory effectiveness in real world situations. Our objective is to evaluate the CIFI as a reliable psychometric tool to assess 1) reliance on visual assistance, 2) telephone use, 3) communication at work, 4) 'hearing' in noise, 5) in groups, and 6) in large room settings. Based upon Guttman scaling properties, the CIFI elicits implanted respondent's functional level with auditory independence from Level 1 (still requiring signing) to level 4 (without any help beyond CI). A blinded, retrospective questionnaire is anonymously answered by cochlear implant recipients. CI centers of tertiary care medical centers, CI support group, and an interactive web page of a hearing and speech center in a large metropolitan region. 245 respondents from a varied adult CI population implanted for one month to 19 years prior to answering the questionnaire. An assessment tool of CI function. A coefficient of reproducibility (CR) for the Guttman scale format equal or greater than 0.90, indicating good scalability. CR in the CIFI was above 0.90. Effective scalability and mean scores from 2.5 to 3.5 for the six areas examined (1.00-4.00) were achieved. The psychometric properties of this user friendly survey demonstrate consistently good scalability. Based on these findings, the CIFI provides a validated tool that can be used for systematic comparisons between groups of patients or for follow-up outcomes in patients who use cochlear implants. Further study is indicated to correlate CIFI scores with sound and speech perception scores. Copyright 2009 John Wiley & Sons, Ltd.
Visual activity predicts auditory recovery from deafness after adult cochlear implantation.
Strelnikov, Kuzma; Rouger, Julien; Demonet, Jean-François; Lagleyre, Sebastien; Fraysse, Bernard; Deguine, Olivier; Barone, Pascal
2013-12-01
Modern cochlear implantation technologies allow deaf patients to understand auditory speech; however, the implants deliver only a coarse auditory input and patients must use long-term adaptive processes to achieve coherent percepts. In adults with post-lingual deafness, the high progress of speech recovery is observed during the first year after cochlear implantation, but there is a large range of variability in the level of cochlear implant outcomes and the temporal evolution of recovery. It has been proposed that when profoundly deaf subjects receive a cochlear implant, the visual cross-modal reorganization of the brain is deleterious for auditory speech recovery. We tested this hypothesis in post-lingually deaf adults by analysing whether brain activity shortly after implantation correlated with the level of auditory recovery 6 months later. Based on brain activity induced by a speech-processing task, we found strong positive correlations in areas outside the auditory cortex. The highest positive correlations were found in the occipital cortex involved in visual processing, as well as in the posterior-temporal cortex known for audio-visual integration. The other area, which positively correlated with auditory speech recovery, was localized in the left inferior frontal area known for speech processing. Our results demonstrate that the visual modality's functional level is related to the proficiency level of auditory recovery. Based on the positive correlation of visual activity with auditory speech recovery, we suggest that visual modality may facilitate the perception of the word's auditory counterpart in communicative situations. The link demonstrated between visual activity and auditory speech perception indicates that visuoauditory synergy is crucial for cross-modal plasticity and fostering speech-comprehension recovery in adult cochlear-implanted deaf patients.
A preliminary study looking at parental emotions following cochlear implantation.
Anagnostou, Flora; Graham, John; Crocker, Susan
2007-06-01
This preliminary research investigated the emotions of parents with cochlear implanted children. The object for the research was first to compare four emotions engendered in parents of deaf children before and after cochlear implantation. Second, to monitor changes in these emotions during a period of up to four years after implantation. Third, to see whether any of the emotions studied was significantly more prominent than the others, and fifth to identify any differences in emotions that were related to the gender of parents. A self-report questionnaire was given to 112 participants of whom 53 replied. There were equal groups of parents in two categories, those with children up to two years after implantation, and those two to four years after implantation. The responses were interpreted using parametric statistics. The results highlight that grief is the strongest emotional condition that parents experience before and up to two years after implantation, alongside family adjustments. Parents of the up to two years after implantation group generally have stronger feelings and are less satisfied than parents in the over two years implanted group. Finally, fathers use denial more than mothers. Considerations for future research and implications for paediatric cochlear implant teams will be discussed. 2007 John Wiley & Sons, Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
..., including cochlear implants, deep brain stimulators, hydrocephalus shunts, spinal cord stimulators, and... pediatric populations, including cochlear implants, deep brain stimulators, hydrocephalus shunts, spinal...
Cochlear Implants in People Who Are Deaf-Blind.
ERIC Educational Resources Information Center
Chute, P. M.; Nevins, M. E.
1995-01-01
This article describes the assessment and rehabilitation processes of three children with deaf-blindness due to Usher syndrome who received cochlear implants at ages six and nine. Follow-up data two and three years after implant for two of the children are analyzed, indicating substantial positive benefits. (DB)
Simultaneous Communication and Cochlear Implants in the Classroom?
ERIC Educational Resources Information Center
Blom, Helen C.; Marschark, Marc
2015-01-01
This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users indicated that the student participants learned…
Deaf Education: The Impact of Cochlear Implantation?
ERIC Educational Resources Information Center
Archbold, Sue; Mayer, Connie
2012-01-01
This paper reviews the impact that cochlear implantation has had on the practice of deaf education in terms of educational placement, communication choices, and educational attainments. Although there is variation in outcome, more children with implants are going to mainstream schools, and using spoken language as their primary means of…
FRIDMAN, GENE Y.; DELLA SANTINA, CHARLES C.
2014-01-01
This article reviews vestibular pathology and the requirements and progress made in the design and construction of a vestibular prosthesis. Bilateral loss of vestibular sensation is disabling. When vestibular hair cells are injured by ototoxic medications or other insults to the labyrinth, the resulting loss of sensory input disrupts vestibulo-ocular reflexes (VORs) and vestibulo-spinal reflexes that normally stabilize the eyes and body. Affected individuals suffer poor vision during head movement, postural instability, chronic disequilibrium, and cognitive distraction. Although most individuals with residual sensation compensate for their loss over time, others fail to do so and have no adequate treatment options. A vestibular prosthesis analogous to cochlear implants but designed to modulate vestibular nerve activity during head movement should improve quality of life for these chronically dizzy individuals. We describe the impact of bilateral loss of vestibular sensation, animal studies supporting feasibility of prosthetic vestibular stimulation, the current status of multichannel vestibular sensory replacement prosthesis development, and challenges to successfully realizing this approach in clinical practice. In bilaterally vestibular-deficient rodents and rhesus monkeys, the Johns Hopkins multichannel vestibular prosthesis (MVP) partially restores the three-dimensional (3D) VOR for head rotations about any axis. Attempts at prosthetic vestibular stimulation of humans have not yet included the 3D eye movement assays necessary to accurately evaluate VOR alignment, but these initial forays have revealed responses that are otherwise comparable to observations in animals. Current efforts now focus on refining electrode design and surgical technique to enhance stimulus selectivity and preserve cochlear function, optimizing stimulus protocols to improve dynamic range and reduce excitation–inhibition asymmetry, and adapting laboratory MVP prototypes into devices appropriate for use in clinical trials. PMID:23044664
Phonological Awareness, Vocabulary, and Reading in Deaf Children with Cochlear Implants
ERIC Educational Resources Information Center
Johnson, Carol; Goswami, Usha
2010-01-01
Purpose: To explore the phonological awareness skills of deaf children with cochlear implants (CIs) and relationships with vocabulary and reading development. Method: Forty-three deaf children with implants who were between 5 and 15 years of age were tested; 21 had been implanted at around 2.5 years of age (Early CI group), and 22 had been…
Speech and language development in cognitively delayed children with cochlear implants.
Holt, Rachael Frush; Kirk, Karen Iler
2005-04-01
The primary goals of this investigation were to examine the speech and language development of deaf children with cochlear implants and mild cognitive delay and to compare their gains with those of children with cochlear implants who do not have this additional impairment. We retrospectively examined the speech and language development of 69 children with pre-lingual deafness. The experimental group consisted of 19 children with cognitive delays and no other disabilities (mean age at implantation = 38 months). The control group consisted of 50 children who did not have cognitive delays or any other identified disability. The control group was stratified by primary communication mode: half used total communication (mean age at implantation = 32 months) and the other half used oral communication (mean age at implantation = 26 months). Children were tested on a variety of standard speech and language measures and one test of auditory skill development at 6-month intervals. The results from each test were collapsed from blocks of two consecutive 6-month intervals to calculate group mean scores before implantation and at 1-year intervals after implantation. The children with cognitive delays and those without such delays demonstrated significant improvement in their speech and language skills over time on every test administered. Children with cognitive delays had significantly lower scores than typically developing children on two of the three measures of receptive and expressive language and had significantly slower rates of auditory-only sentence recognition development. Finally, there were no significant group differences in auditory skill development based on parental reports or in auditory-only or multimodal word recognition. The results suggest that deaf children with mild cognitive impairments benefit from cochlear implantation. Specifically, improvements are evident in their ability to perceive speech and in their reception and use of language. However, it may be reduced relative to their typically developing peers with cochlear implants, particularly in domains that require higher level skills, such as sentence recognition and receptive and expressive language. These findings suggest that children with mild cognitive deficits be considered for cochlear implantation with less trepidation than has been the case in the past. Although their speech and language gains may be tempered by their cognitive abilities, these limitations do not appear to preclude benefit from cochlear implant stimulation, as assessed by traditional measures of speech and language development.
A physiological and behavioral system for hearing restoration with cochlear implants
King, Julia; Shehu, Ina; Roland, J. Thomas; Svirsky, Mario A.
2016-01-01
Cochlear implants are neuroprosthetic devices that provide hearing to deaf patients, although outcomes are highly variable even with prolonged training and use. The central auditory system must process cochlear implant signals, but it is unclear how neural circuits adapt—or fail to adapt—to such inputs. The knowledge of these mechanisms is required for development of next-generation neuroprosthetics that interface with existing neural circuits and enable synaptic plasticity to improve perceptual outcomes. Here, we describe a new system for cochlear implant insertion, stimulation, and behavioral training in rats. Animals were first ensured to have significant hearing loss via physiological and behavioral criteria. We developed a surgical approach for multichannel (2- or 8-channel) array insertion, comparable with implantation procedures and depth in humans. Peripheral and cortical responses to stimulation were used to program the implant objectively. Animals fitted with implants learned to use them for an auditory-dependent task that assesses frequency detection and recognition in a background of environmentally and self-generated noise and ceased responding appropriately to sounds when the implant was temporarily inactivated. This physiologically calibrated and behaviorally validated system provides a powerful opportunity to study the neural basis of neuroprosthetic device use and plasticity. PMID:27281743
Cochlear Implants (For Parents)
... nerve, and send it to the brain. The cochlear implant package is made up of: a receiver-stimulator that contains all of the electronic circuits that control the flow of electrical pulses into the ear an antenna ...
Are There Treatments That Can Help Me?
... tinnitus in a significant number of study volunteers. Cochlear implants are sometimes used in people who have tinnitus along with severe hearing loss. A cochlear implant bypasses the damaged portion of the inner ...
Kiefer, J; Weber, A; Pfennigdorff, T; von Ilberg, C
2000-01-01
Insertion of a sufficient number of electrodes is important for a successful use of cochlear implants. We investigated the results of scala vestibuli insertion for cochlear implantation in cases of obstructed scala tympani. In a series of 200 cochlear implantations, scala vestibuli insertion was successfully performed in 4 cases with obstruction of the scala tympani. Etiologies included a temporal bone fracture, severe otosclerosis and malformations of the cochlea. The maximum insertion depth obtained via the scala vestibuli was 30 mm. Postoperative results were comparable to patients in whom conventional scala tympani insertion was performed. No adverse effects related to the site of insertion were observed. Scala vestibuli insertion offers a valuable alternative in cases of obstructed scala tympani that can be employed for a variety of etiologies. Copyright 2000 S. Karger AG, Basel
Intraoperative seizure and cerebrospinal fluid leak during adult cochlear implant surgery.
Musser, Alexander B; Golub, Justin S; Samy, Ravi N; Phero, James C
2016-01-01
To report a rare case of cerebrospinal fluid gusher and subsequent seizure immediately after cochlear implant electrode insertion. After the cochlear implant electrode was inserted, brisk flow of 10 mL of cerebrospinal fluid was seen. The electrode was promptly inserted and the leak was additionally sealed with fascia. Seconds later, the patient had a tonic-clonic seizure lasting 30 seconds. Two additional episodes occurred during the case. Her postoperative course was uneventful with no subsequent seizures. The device has been successfully activated. Intervention & Technique: Postoperative imaging showed correct intracochlear placement of the electrode as well as an incidental enlarged vestibular aqueduct. Neurology consultation including electroencephalogram was unremarkable. To our knowledge, this is the first report of a seizure temporally associated with cochlear implant electrode insertion. The significance and possible casual relationship between these two events is discussed.
Jenkins, Herman A; Uhler, Kristin
2012-01-01
To compare the speech understanding abilities of cochlear implant listeners using 2 microphone technologies, the Otologics fully implantable Carina and the Cochlear Freedom microphones. Feasibility study using direct comparison of the 2 microphones, nonrandomized and nonblinded within case studies. Tertiary referral center hospital outpatient clinic. Four subjects with greater than 1 year of unilateral listening experience with the Freedom Cochlear Implant and a CNC word score higher than 40%. A Carina microphone coupled to a percutaneous plug was implanted on the ipsilateral side of the cochlear implant. Two months were allowed for healing before connecting to the Carina microphone. The percutaneous plug was connected to a body worn external processor with output leads inserted into the auxiliary port of the Freedom processor. Subjects were instructed to use each of the 2 microphones for half of their daily implant use. Aided pure tone thresholds, consonant-nucleus-consonant (CNC), Bamford-Kowel-Bench Speech in Noise test (BKN-SIN), and Abbreviated Profile of Hearing Aid Benefit. All subjects had sound perceptions using both microphones. The loudness and quality of the sound was judged to be poorer with the Carina in the first 2 subjects. The latter 2 demonstrated essential equivalence in the second two listeners, with the exception of the Abbreviated Profile of Hearing Aid Benefit reporting greater percentage of problems for the Carina in the background noise situation for subject 0011-003PP. CNC word scores were better with the Freedom than the Carina in all 4 subjects. The latter 2 showed improved speech perception abilities with the Carina, compared with the first 2. The BKB-SIN showed consistently better results with the Freedom in noise. Early observations indicate that it is potentially feasible to use the fully implanted Carina microphone with the Freedom Cochlear Implant. The authors would anticipate that outcomes would improve as more knowledge is gained in signal processing and with the fabrication of an integrated device.
The early days of the multi channel cochlear implant: efforts and achievement in France.
Chouard, C H
2015-04-01
On September 10th 2013, the clinical medical research Lasker award winners were rewarded for their work on multichannel cochlear implant. It has been my pleasure to see that such a major topic had caught the attention of the Members of the Jury for this prestigious award. That is why I accepted an invitation to participate in a special issue of Hearing Research devoted to the three winners. Here I highlight four scientific contributions made by the French team in late 1970s and early 1980s to modern multichannel cochlear implant development. 1) Chouard and MacLeod plotted an approximate frequency map of the whole length of the human cochlea, including its "hidden face" corresponding to speech frequencies. Moreover MacLeod suggested a sequential display of electrical stimulation as a function of each electrode, a precursor to today's electrodogram and interleaved stimulation. 2) Chouard performed total cochlear implantation in a deaf adult male with 8 electrically independent electrodes that were evenly distributed along the cochlea. 3) Chouard and MacLeod described in a patent detailed sound signal processing for a functional multichannel cochlear implant and reported speech discrimination without help of lip reading in some totally deafened patients. 4) Chouard experimentally demonstrated in the guinea pig the advantage of early cochlear implantation in treating profound neonatal deafness. This article is part of a Special Issue entitled
Speech Intelligibility and Prosody Production in Children with Cochlear Implants
Chin, Steven B.; Bergeson, Tonya R.; Phan, Jennifer
2012-01-01
Objectives The purpose of the current study was to examine the relation between speech intelligibility and prosody production in children who use cochlear implants. Methods The Beginner's Intelligibility Test (BIT) and Prosodic Utterance Production (PUP) task were administered to 15 children who use cochlear implants and 10 children with normal hearing. Adult listeners with normal hearing judged the intelligibility of the words in the BIT sentences, identified the PUP sentences as one of four grammatical or emotional moods (i.e., declarative, interrogative, happy, or sad), and rated the PUP sentences according to how well they thought the child conveyed the designated mood. Results Percent correct scores were higher for intelligibility than for prosody and higher for children with normal hearing than for children with cochlear implants. Declarative sentences were most readily identified and received the highest ratings by adult listeners; interrogative sentences were least readily identified and received the lowest ratings. Correlations between intelligibility and all mood identification and rating scores except declarative were not significant. Discussion The findings suggest that the development of speech intelligibility progresses ahead of prosody in both children with cochlear implants and children with normal hearing; however, children with normal hearing still perform better than children with cochlear implants on measures of intelligibility and prosody even after accounting for hearing age. Problems with interrogative intonation may be related to more general restrictions on rising intonation, and the correlation results indicate that intelligibility and sentence intonation may be relatively dissociated at these ages. PMID:22717120
Assessment of Appalachian region pediatric hearing healthcare disparities and delays.
Bush, Matthew L; Osetinsky, Mariel; Shinn, Jennifer B; Gal, Thomas J; Ding, Xiuhua; Fardo, David W; Schoenberg, Nancy
2014-07-01
The purpose of this study was to examine the timing of diagnostic and therapeutic services in cochlear implant recipients from a rural Appalachian region with healthcare disparity. Retrospective analysis. Cochlear implant recipients from a tertiary referral center born with severe congenital sensorineural hearing loss were examined. Rural status and Appalachian status of their county of origin were recorded. A log-rank test was used to examine differences in the distributions of time to definitive diagnosis of hearing loss, initial amplification fitting, and cochlear implantation in these children. Correlation analysis of the rural status of each county and the timing of services was assessed. A total of 53 children born with congenital hearing loss were included in the study (36 from rural counties and 17 from urban/suburban counties). The distribution of weeks after birth to diagnosis (P=.006), amplification (P=.030), and cochlear implantation (P=.002) was delayed in rural children compared with urban children. An analysis factoring in the effect of implementation of mandatory infant hearing screening in 2000 demonstrated a similar delay in rural children for weeks to diagnosis (P=.028), amplification (P=.087), and cochlear implantation (P<.0001). Children with severe hearing loss in very rural areas, such as Appalachia, may have significant delays in diagnostic and rehabilitative services. Further investigation is warranted to assess causative factors in delays of cochlear implantation and to develop interventions to promote timely diagnosis and care. 3b. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Modelling the effect of round window stiffness on residual hearing after cochlear implantation.
Elliott, Stephen J; Ni, Guangjian; Verschuur, Carl A
2016-11-01
Preservation of residual hearing after cochlear implantation is now considered an important goal of surgery. However, studies indicate an average post-operative hearing loss of around 20 dB at low frequencies. One factor which may contribute to post-operative hearing loss, but which has received little attention in the literature to date, is the increased stiffness of the round window, due to the physical presence of the cochlear implant, and to its subsequent thickening or to bone growth around it. A finite element model was used to estimate that there is approximately a 100-fold increase in the round window stiffness due to a cochlear implant passing through it. A lumped element model was then developed to study the effects of this change in stiffness on the acoustic response of the cochlea. As the round window stiffness increases, the effects of the cochlear and vestibular aqueducts become more important. An increase of round window stiffness by a factor of 10 is predicted to have little effect on residual hearing, but increasing this stiffness by a factor of 100 reduces the acoustic sensitivity of the cochlea by about 20 dB, below 1 kHz, in reasonable agreement with the observed loss in residual hearing after implantation. It is also shown that the effect of this stiffening could be reduced by incorporating a small gas bubble within the cochlear implant. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Hixon, Brian; Chan, Stephen; Adkins, Margaret; Shinn, Jennifer B.; Bush, Matthew L.
2016-01-01
Objective The purpose of this study is to compare the timing and impact of hearing healthcare of rural and urban adults with severe hearing loss who use cochlear implants (CI). Study Design Cross-sectional questionnaire study Setting Tertiary referral center Patients Adult cochlear implant recipients. Main Outcome Measures Data collected included county of residence, socioeconomic information, impact of hearing loss on education/employment, and timing of hearing loss treatment. The benefits obtained from cochlear implantation were also evaluated. Results There were 91 participants (32 from urban counties, 26 from moderately rural counties, and 33 for extremely rural counties). Rural participants have a longer commute time to the CI center (p<0.001), lower income (p<0.001) and higher percentage of Medicaid coverage (p=0.004). Compared with urban-metro participants, rural participants with gradually progressive hearing loss had a greater time interval from the onset of hearing loss to obtaining hearing aid amplification (10 years versus 5 years, p=0.04). There was also a greater time interval from onset of hearing loss to the time of cochlear implantation in rural participants (p=0.04). Reported job loss was higher in rural participants than in urban participants (p=0.05). Both groups reported comparable benefit from cochlear implantation. Conclusions Rural CI recipients differ from urban residents in socioeconomic characteristics and may be delayed in timely treatment of hearing loss. Further efforts to expand access to hearing healthcare services may benefit rural adult patients. PMID:27636389
Hixon, Brian; Chan, Stephen; Adkins, Margaret; Shinn, Jennifer B; Bush, Matthew L
2016-10-01
The purpose of this study is to compare the timing and impact of hearing healthcare of rural and urban adults with severe hearing loss who use cochlear implants (CI). Cross-sectional questionnaire study. Tertiary referral center. Adult cochlear implant recipients. Data collected included county of residence, socioeconomic information, impact of hearing loss on education/employment, and timing of hearing loss treatment. The benefits obtained from cochlear implantation were also evaluated. There were 91 participants (32 from urban counties, 26 from moderately rural counties, and 33 for extremely rural counties). Rural participants have a longer commute time to the CI center (p < 0.001), lower income (p < 0.001), and higher percentage of Medicaid coverage (p = 0.004). Compared with urban-metro participants, rural participants with gradually progressive hearing loss had a greater time interval from the onset of hearing loss to obtaining hearing aid amplification (10 yr versus 5 yr, p = 0.04). There was also a greater time interval from onset of hearing loss to the time of cochlear implantation in rural participants (p = 0.04). Reported job loss was higher in rural participants than in urban participants (p = 0.05). Both groups reported comparable benefit from cochlear implantation. Rural CI recipients differ from urban residents in socioeconomic characteristics and may be delayed in timely treatment of hearing loss. Further efforts to expand access to hearing healthcare services may benefit rural adult patients.