Sample records for bio-plex suspension array

  1. Rapid Identification of Shiga Toxin-Producing Escherichia coli O Serogroups from Fresh Produce and Raw Milk Enrichment Cultures by Luminex Bead-Based Suspension Array.

    PubMed

    Kase, Julie A; Maounounen-Laasri, Anna; Lin, Andrew

    2016-09-01

    The U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) Chapter 4a describes a Luminex microbead-based suspension array used to screen colonies for 11 clinically relevant Shiga toxin-producing Escherichia coli (STEC) serogroups: O26, O45, O91, O103, O104, O111, O113, O121, O128, O145, and O157. We evaluated the usefulness of this method to identify STEC-positive enrichment samples before agar plating. Twelve E. coli strains were added to three types of fresh produce (bagged baby spinach, alfalfa sprouts, and cilantro) at levels near the detection limit of the test. A subset of these strains (six O serogroups) was similarly evaluated in raw milk. For comparison, portions of each of the 168 enrichment cultures were analyzed for serogroup by a real-time PCR assay and a Bio-Plex 200 assay with the bead-based suspensions. No false-positive results were obtained. Of the 112 samples with a reported cycle threshold (C T ) value, 101 undiluted, diluted, or extracted enrichment cultures also produced ratios above 5.0 in the Bio-Plex assay. When PCR C T values approached or were greater than 35, Bio-Plex detection became less reliable. Using undiluted or extracted enrichment cultures resulted in a significantly larger number of positive results. With the same enrichment material prepared for real-time PCR analysis as described in the BAM Chapter 4a, the STEC microbead-based suspension array can accurately screen food enrichment cultures.

  2. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    PubMed

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  3. Molecular identification of common Salmonella serovars using multiplex DNA sensor-based suspension array.

    PubMed

    Aydin, Muhsin; Carter-Conger, Jacqueline; Gao, Ning; Gilmore, David F; Ricke, Steven C; Ahn, Soohyoun

    2018-04-01

    Salmonella is one of major foodborne pathogens and the leading cause of foodborne illness-related hospitalizations and deaths. It is critical to develop a sensitive and rapid detection assay that can identify Salmonella to ensure food safety. In this study, a DNA sensor-based suspension array system of high multiplexing ability was developed to identify eight Salmonella serovars commonly associated with foodborne outbreaks to the serotype level. Each DNA sensor was prepared by activating pre-encoded microspheres with oligonucleotide probes that are targeting virulence genes and serovar-specific regions. The mixture of 12 different types of DNA sensors were loaded into a 96-well microplate and used as a 12-plex DNA sensor array platform. DNA isolated from Salmonella was amplified by multiplex polymerase chain reaction (mPCR), and the presence of Salmonella was determined by reading fluorescent signals from hybridization between probes on DNA sensors and fluorescently labeled target DNA using the Bio-Plex® system. The developed multiplex array was able to detect synthetic DNA at the concentration as low as 100 fM and various Salmonella serovars as low as 100 CFU/mL within 1 h post-PCR. Sensitivity of this assay was further improved to 1 CFU/mL with 6-h enrichment. The array system also correctly and specifically identified serotype of tested Salmonella strains without any cross-reactivity with other common foodborne pathogens. Our results indicate the developed DNA sensor suspension array can be a rapid and reliable high-throughput method for simultaneous detection and molecular identification of common Salmonella serotypes.

  4. Comparison of two suspension arrays for simultaneous detection of five biothreat bacterial in powder samples.

    PubMed

    Yang, Yu; Wang, Jing; Wen, Haiyan; Liu, Hengchuan

    2012-01-01

    We have developed novel Bio-Plex assays for simultaneous detection of Bacillus anthracis, Yersinia pestis, Brucella spp., Francisella tularensis, and Burkholderia pseudomallei. Universal primers were used to amplify highly conserved region located within the 16S rRNA amplicon, followed by hybridized to pathogen-specific probes for identification of these five organisms. The other assay is based on multiplex PCR to simultaneously amplify five species-specific pathogen identification-targeted regions unique to individual pathogen. Both of the two arrays are validated to be flexible and sensitive for simultaneous detection of bioterrorism bacteria. However, universal primer PCR-based array could not identify Bacillus anthracis, Yersinia pestis, and Brucella spp. at the species level because of the high conservation of 16S rDNA of the same genus. The two suspension arrays can be utilized to detect Bacillus anthracis sterne spore and Yersinia pestis EV76 from mimic "write powder" samples, they also proved that the suspension array system will be valuable tools for diagnosis of bacterial biothreat agents in environmental samples.

  5. Development of a Multiplexed Bead-Based Suspension Array for the Detection and Discrimination of Pospiviroid Plant Pathogens

    PubMed Central

    van Brunschot, Sharon L.; Bergervoet, Jan H. W.; Pagendam, Daniel E.; de Weerdt, Marjanne; Geering, Andrew D. W.; Drenth, André; van der Vlugt, René A. A.

    2014-01-01

    Efficient and reliable diagnostic tools for the routine indexing and certification of clean propagating material are essential for the management of pospiviroid diseases in horticultural crops. This study describes the development of a true multiplexed diagnostic method for the detection and identification of all nine currently recognized pospiviroid species in one assay using Luminex bead-based suspension array technology. In addition, a new data-driven, statistical method is presented for establishing thresholds for positivity for individual assays within multiplexed arrays. When applied to the multiplexed array data generated in this study, the new method was shown to have better control of false positives and false negative results than two other commonly used approaches for setting thresholds. The 11-plex Luminex MagPlex-TAG pospiviroid array described here has a unique hierarchical assay design, incorporating a near-universal assay in addition to nine species-specific assays, and a co-amplified plant internal control assay for quality assurance purposes. All assays of the multiplexed array were shown to be 100% specific, sensitive and reproducible. The multiplexed array described herein is robust, easy to use, displays unambiguous results and has strong potential for use in routine pospiviroid indexing to improve disease management strategies. PMID:24404188

  6. Multicenter Evaluation of the ePlex Respiratory Pathogen Panel for the Detection of Viral and Bacterial Respiratory Tract Pathogens in Nasopharyngeal Swabs

    PubMed Central

    England, Matthew R.; Jurcic Smith, Kristen L.; He, Taojun; Wijetunge, Dona Saumya; Chamberland, Robin R.; Menegus, Marilyn; Swierkosz, Ella M.; Jerris, Robert C.; Greene, Wallace

    2017-01-01

    ABSTRACT The performance of the new ePlex Respiratory Pathogen (RP) panel (GenMark Diagnostics) for the simultaneous detection of 19 viruses (influenza A virus; influenza A H1 virus; influenza A 2009 H1 virus; influenza A H3 virus; influenza B virus; adenovirus; coronaviruses [HKU1, OC43, NL63, and 229E]; human rhinovirus/enterovirus; human metapneumovirus; parainfluenza viruses 1, 2, 3, and 4; and respiratory syncytial virus [RSV] [RSV subtype A and RSV subtype B]) and 2 bacteria (Mycoplasma pneumoniae and Chlamydia pneumoniae) was evaluated. Prospectively and retrospectively collected nasopharyngeal swab (NPS) specimens (n = 2,908) were evaluated by using the ePlex RP panel, with the bioMérieux/BioFire FilmArray Respiratory Panel (BioFire RP) as the comparator method. Discordance analysis was performed by using target-specific PCRs and bidirectional sequencing. The reproducibility of the assay was evaluated by using reproducibility panels comprised of 6 pathogens. The overall agreement between the ePlex RP and BioFire RP results was >95% for all targets. Positive percent agreement with the BioFire RP result for viruses ranged from 85.1% (95% confidence interval [CI], 80.2% to 88.9%) to 95.1% (95% CI, 89.0% to 97.9%), while negative percent agreement values ranged from 99.5% (95% CI, 99.1% to 99.7%) to 99.8% (95% CI, 99.5% to 99.9%). Additional testing of discordant targets (12%; 349/2,908) confirmed the results of ePlex RP for 38% (131/349) of samples tested. Reproducibility was 100% for all targets tested, with the exception of adenovirus, for which reproducibilities were 91.6% at low virus concentrations and 100% at moderate virus concentrations. The ePlex RP panel offers a new, rapid, and sensitive “sample-to-answer” multiplex panel for the detection of the most common viral and bacterial respiratory pathogens. PMID:29212701

  7. Improving efficiency of a small forensic DNA laboratory: validation of robotic assays and evaluation of microcapillary array device.

    PubMed

    Crouse, Cecelia A; Yeung, Stephanie; Greenspoon, Susan; McGuckian, Amy; Sikorsky, Julie; Ban, Jeff; Mathies, Richard

    2005-08-01

    To present validation studies performed for the implementation of existing and new technologies to increase the efficiency in the forensic DNA Section of the Palm Beach County Sheriff's Office (PBSO) Crime Laboratory. Using federally funded grants, internal support, and an external Process Mapping Team, the PBSO collaborated with forensic vendors, universities, and other forensic laboratories to enhance DNA testing procedures, including validation of the DNA IQ magnetic bead extraction system, robotic DNA extraction using the BioMek2000, the ABI7000 Sequence Detection System, and is currently evaluating a micro Capillary Array Electrophoresis device. The PBSO successfully validated and implemented both manual and automated Promega DNA IQ magnetic bead extractions system, which have increased DNA profile results from samples with low DNA template concentrations. The Beckman BioMek2000 DNA robotic workstation has been validated for blood, tissue, bone, hair, epithelial cells (touch evidence), and mixed stains such as semen. There has been a dramatic increase in the number of samples tested per case since implementation of the robotic extraction protocols. The validation of the ABI7000 real-time quantitative polymerase chain reaction (qPCR) technology and the single multiplex short tandem repeat (STR) PowerPlex16 BIO amplification system has provided both a time and a financial benefit. In addition, the qPCR system allows more accurate DNA concentration data and the PowerPlex 16 BIO multiplex generates DNA profiles data in half the time when compared to PowerPlex1.1 and PowerPlex2.1 STR systems. The PBSO's future efficiency requirements are being addressed through collaboration with the University of California at Berkeley and the Virginia Division of Forensic Science to validate microcapillary array electrophoresis instrumentation. Initial data demonstrated the electrophoresis of 96 samples in less than twenty minutes. The PBSO demonstrated, through the validation of more efficient extraction and quantification technology, an increase in the number of evidence samples tested using robotic/DNA IQ magnetic bead DNA extraction, a decrease in the number of negative samples amplified due to qPCR and implementation of a single multiplex amplification system. In addition, initial studies show the microcapillary array electrophoresis device (microCAE) evaluation results provide greater sensitivity and faster STR analysis output than current platforms.

  8. Magnetic bead based immuno-detection of Listeria monocytogenes and Listeria ivanovii from infant formula and leafy green vegetables using the Bio-Plex suspension array system.

    PubMed

    Day, J B; Basavanna, U

    2015-04-01

    Listeriosis, a disease contracted via the consumption of foods contaminated with pathogenic Listeria species, can produce severe symptoms and high mortality in susceptible people and animals. The development of molecular methods and immuno-based techniques for detection of pathogenic Listeria in foods has been challenging due to the presence of assay inhibiting food components. In this study, we utilize a macrophage cell culture system for the isolation and enrichment of Listeria monocytogenes and Listeria ivanovii from infant formula and leafy green vegetables for subsequent identification using the Luminex xMAP technique. Macrophage monolayers were exposed to infant formula, lettuce and celery contaminated with L. monocytogenes or L. ivanovii. Magnetic microspheres conjugated to Listeria specific antibody were used to capture Listeria from infected macrophages and then analyzed using the Bio-Plex 200 analyzer. As few as 10 CFU/mL or g of L. monocytogenes was detected in all foods tested. The detection limit for L. ivanovii was 10 CFU/mL in infant formula and 100 CFU/g in leafy greens. Microsphere bound Listeria obtained from infected macrophage lysates could also be isolated on selective media for subsequent confirmatory identification. This method presumptively identifies L. monocytogenes and L. ivanovii from infant formula, lettuce and celery in less than 28 h with confirmatory identifications completed in less than 48 h. Published by Elsevier Ltd.

  9. BioPlex Display: An Interactive Suite for Large-Scale AP-MS Protein-Protein Interaction Data.

    PubMed

    Schweppe, Devin K; Huttlin, Edward L; Harper, J Wade; Gygi, Steven P

    2018-01-05

    The development of large-scale data sets requires a new means to display and disseminate research studies to large audiences. Knowledge of protein-protein interaction (PPI) networks has become a principle interest of many groups within the field of proteomics. At the confluence of technologies, such as cross-linking mass spectrometry, yeast two-hybrid, protein cofractionation, and affinity purification mass spectrometry (AP-MS), detection of PPIs can uncover novel biological inferences at a high-throughput. Thus new platforms to provide community access to large data sets are necessary. To this end, we have developed a web application that enables exploration and dissemination of the growing BioPlex interaction network. BioPlex is a large-scale interactome data set based on AP-MS of baits from the human ORFeome. The latest BioPlex data set release (BioPlex 2.0) contains 56 553 interactions from 5891 AP-MS experiments. To improve community access to this vast compendium of interactions, we developed BioPlex Display, which integrates individual protein querying, access to empirical data, and on-the-fly annotation of networks within an easy-to-use and mobile web application. BioPlex Display enables rapid acquisition of data from BioPlex and development of hypotheses based on protein interactions.

  10. Identification of Brucella genus and eight Brucella species by Luminex bead-based suspension array.

    PubMed

    Lusk Pfefer, Tina S; Timme, Ruth; Kase, Julie A

    2018-04-01

    Globally, unpasteurized milk products are vehicles for the transmission of brucellosis, a zoonosis responsible for cases of foodborne illness in the United States and elsewhere. Existing PCR assays to detect Brucella species are restricted by the resolution of band sizes on a gel or the number of fluorescent channels in a single real-time system. The Luminex bead-based suspension array is performed in a 96-well plate allowing for high throughput screening of up to 100 targets in one sample with easily discernible results. We have developed an array using the Bio-Plex 200 to differentiate the most common Brucella species: B. abortus, B. melitensis, B. suis, B. suis bv5, B. canis, B. ovis, B. pinnipedia, and B. neotomae, as well as Brucella genus. All probes showed high specificity, with no cross-reaction with non-Brucella strains. We could detect pure DNA from B. abortus, B. melitensis, and genus-level Brucella at concentrations of ≤5 fg/μL. Pure DNA from all other species tested positive at concentrations well below 500 fg/μL and we positively identified B. neotomae in six artificially contaminated cheese and milk products. An intra-laboratory verification further demonstrated the assay's accuracy and robustness in the rapid screening (3-4 h including PCR) of DNA. Published by Elsevier Ltd.

  11. Performance of the BioPlex 2200 HIV Ag-Ab assay for identifying acute HIV infection.

    PubMed

    Eshleman, Susan H; Piwowar-Manning, Estelle; Sivay, Mariya V; Debevec, Barbara; Veater, Stephanie; McKinstry, Laura; Bekker, Linda-Gail; Mannheimer, Sharon; Grant, Robert M; Chesney, Margaret A; Coates, Thomas J; Koblin, Beryl A; Fogel, Jessica M

    Assays that detect HIV antigen (Ag) and antibody (Ab) can be used to screen for HIV infection. To compare the performance of the BioPlex 2200 HIV Ag-Ab assay and two other Ag/Ab combination assays for detection of acute HIV infection. Samples were obtained from 24 individuals (18 from the US, 6 from South Africa); these individuals were classified as having acute infection based on the following criteria: positive qualitative RNA assay; two negative rapid tests; negative discriminatory test. The samples were tested with the BioPlex assay, the ARCHITECT HIV Ag/Ab Combo test, the Bio-Rad GS HIV Combo Ag-Ab EIA test, and a viral load assay. Twelve (50.0%) of 24 samples had RNA detected only ( > 40 to 13,476 copies/mL). Ten (43.5%) samples had reactive results with all three Ag/Ab assays, one sample was reactive with the ARCHITECT and Bio-Rad assays, and one sample was reactive with the Bio-Rad and BioPlex assays. The 11 samples that were reactive with the BioPlex assay had viral loads from 83,010 to >750,000 copies/mL; 9/11 samples were classified as Ag positive/Ab negative by the BioPlex assay. Detection of acute HIV infection was similar for the BioPlex assay and two other Ag/Ab assays. All three tests were less sensitive than a qualitative RNA assay and only detected HIV Ag when the viral load was high. The BioPlex assay detected acute infection in about half of the cases, and identified most of those infections as Ag positive/Ab negative. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Comparison of Multiplex Suspension Array Large-Panel Kits for Profiling Cytokines and Chemokines in Rheumatoid Arthritis Patients

    PubMed Central

    Khan, Imran H.; Krishnan, V.V.; Ziman, Melanie; Janatpour, Kim; Wun, Ted; Luciw, Paul A.; Tuscano, Joseph

    2015-01-01

    Background Multiplex analysis allows measurements of a large number of analytes simultaneously in each sample. Based on the Luminex multiplex technology (xMAP), kits for measuring multiple cytokines and chemokines (immunomodulators) are commercially available and are useful in investigations on inflammatory diseases. This study evaluated four multiplex kits (Bio-Plex, LINCOplex, Fluorokine, and Beadlyte) that contained 27, 29, 20 and 22 analytes each, respectively, for the analysis of immunomodulators in plasma of rheumatoid arthritis (RA) patients who underwent treatment with antibody against CD20 (rituximab), a B-cell reductive therapy. Methods Multiplex kits were tested on serial plasma samples obtained from six RA patients at baseline and multiple time points (3, 6, and 9 months) post-treatment with rituximab. The RA patients included in this study had previously failed therapy with disease modifying anti-arthritis drugs (DMARD) and treatment with anti-TNFα antibody (infliximab). Results Computer modeling and hierarchical cluster analysis of the multiplex data allowed a comparison of the performance of multiplex assay kits and revealed profiles of immunomodulators in the RA patients. Conclusions In plasma of RA patients who appeared to have benefited from rituximab treatment the profile of significantly elevated immunomodulators by at least two of the three kits (BioPlex, LINCOplex, Beadlyte), is as follows: IL-12p70, Eotaxin, IL-4, TNFα, Il-9, IL-1β, IFNγ, IL-10, IL-6, and IL-13. Immunomodulator profiling by multiplex analysis may provide useful plasma biomarkers for monitoring response to B-cell reductive therapy in RA patients. PMID:18823005

  13. Development, Characterisation and Application of Monoclonal Antibodies for the Detection and Quantification of Infectious Salmon Anaemia Virus in Plasma Samples Using Luminex Bead Array Technology.

    PubMed

    Hoare, R; Thompson, K D; Herath, T; Collet, B; Bron, J E; Adams, A

    2016-01-01

    Infectious salmon anaemia virus (ISAV) is an orthomyxovirus that has had a significant economic impact on Atlantic salmon farming in Europe, North America and Chile. Monoclonal antibodies (mAbs) were developed against Segment 3 (encoding the viral nucleoprotein, NP) of the virus. Six of the mAbs were shown to be specific to ISAV and recognised all isolates from Scotland, Norway and Canada. They reacted with ISAV in enzyme-linked immunosorbent assay (ELISA), indirect fluorescent antibody technique (IFAT) and western blotting. They were also used to develop a novel detection method based on Luminex (Bio-Plex) bead-based flow cytometric technology for the detection of ISAV in the plasma of Atlantic salmon (Salmo salar L.) smolts experimentally infected with ISAV. Fish were challenged by intraperitoneal (i.p.) injection of virus at 50% Tissue Culture Infective Dose (TCID50) = 2.8 x106 per animal. Virus present in plasma of infected fish, collected at 0, 4, 8, 12, 16, 21 and 28 days post infection using a non-lethal sampling method (n = 12 at each time point), was quantified using the optimised Bio-Plex assay. The results obtained with this assay were compared with absolute quantification of the virus by RT-qPCR using SYBR Green I and TaqMan chemistries. The Bio-Plex assay developed using the NP mAbs appears to be a rapid, sensitive method for detecting and quantifying ISAV in small volumes of fish plasma and has the potential to be multiplexed for the detection of other fish pathogens (e.g. during co-infections). To our knowledge this is the first report of the use of Luminex (Bio-Plex) technology for the detection of a fish pathogen.

  14. Comparison of three anti-dsDNA assays: performance and correlation with systemic lupus erythematosus disease activity.

    PubMed

    Venner, Allison A; Ibañez, Dominique; Gladman, Dafna D; Urowitz, Murray B; MacKinnon, Anne; Blasutig, Ivan M; Yip, Paul M

    2013-03-01

    To investigate the BioPlex 2200 multiplex immunoassay and Farrzyme ELISA assays as alternatives to the established Farr radioimmunoassay for the correlation of anti-dsDNA antibodies in the assessment of disease activity in systemic lupus erythematosus (SLE). Standard protocols were used to verify analytical performance claims. Anti-dsDNA antibody levels in SLE patient specimens (N=105) were measured and assessed for clinical performance using manufacturer cut-off limits along with the Systemic Lupus Erythematosus Disease Activity Index 2000 (SLEDAI-2K) score. Assay precision, measurable range and normal reference interval met the manufacturers' stated claims. Agreement between Farr and BioPlex assays was moderate (positive agreement=62%; negative agreement=85%; kappa=0.48), as was agreement between Farr and Farrzyme assays (positive agreement=56%; negative agreement=91%; kappa=0.51). Mean SLEDAI-2K scores differed significantly between the anti-dsDNA positive and negative groups for BioPlex (p=0.0006), but not Farr (p=0.11) or Farrzyme (p=0.34). ROC curve analysis showed a similar area under the curve (AUC) for all three assays (0.76, 0.74, and 0.73 for Farr, BioPlex, and Farrzyme, respectively) in the discrimination of clinically active disease. Furthermore, increased anti-dsDNA levels from BioPlex showed significant correlation with active renal disease. However, results suggested a lower cut-off for the Farrzyme assay for assessment of global disease activity. BioPlex and Farrzyme assays had similar overall agreement with the Farr assay, with BioPlex best reflecting disease activity in SLE patients. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Dynamic Model of the BIO-Plex Air Revitalization System

    NASA Technical Reports Server (NTRS)

    Finn, Cory; Meyers, Karen; Duffield, Bruce; Luna, Bernadette (Technical Monitor)

    2000-01-01

    The BIO-Plex facility will need to support a variety of life support system designs and operation strategies. These systems will be tested and evaluated in the BIO-Plex facility. An important goal of the life support program is to identify designs that best meet all size and performance constraints for a variety of possible future missions. Integrated human testing is a necessary step in reaching this goal. System modeling and analysis will also play an important role in this endeavor. Currently, simulation studies are being used to estimate air revitalization buffer and storage requirements in order to develop the infrastructure requirements of the BIO-Plex facility. Simulation studies are also being used to verify that the envisioned operation strategy will be able to meet all performance criteria. In this paper, a simulation study is presented for a nominal BIO-Plex scenario with a high-level of crop growth. A general description of the dynamic mass flow model is provided, along with some simulation results. The paper also discusses sizing and operations issues and describes plans for future simulation studies.

  16. The BioPlex Network: A Systematic Exploration of the Human Interactome.

    PubMed

    Huttlin, Edward L; Ting, Lily; Bruckner, Raphael J; Gebreab, Fana; Gygi, Melanie P; Szpyt, John; Tam, Stanley; Zarraga, Gabriela; Colby, Greg; Baltier, Kurt; Dong, Rui; Guarani, Virginia; Vaites, Laura Pontano; Ordureau, Alban; Rad, Ramin; Erickson, Brian K; Wühr, Martin; Chick, Joel; Zhai, Bo; Kolippakkam, Deepak; Mintseris, Julian; Obar, Robert A; Harris, Tim; Artavanis-Tsakonas, Spyros; Sowa, Mathew E; De Camilli, Pietro; Paulo, Joao A; Harper, J Wade; Gygi, Steven P

    2015-07-16

    Protein interactions form a network whose structure drives cellular function and whose organization informs biological inquiry. Using high-throughput affinity-purification mass spectrometry, we identify interacting partners for 2,594 human proteins in HEK293T cells. The resulting network (BioPlex) contains 23,744 interactions among 7,668 proteins with 86% previously undocumented. BioPlex accurately depicts known complexes, attaining 80%-100% coverage for most CORUM complexes. The network readily subdivides into communities that correspond to complexes or clusters of functionally related proteins. More generally, network architecture reflects cellular localization, biological process, and molecular function, enabling functional characterization of thousands of proteins. Network structure also reveals associations among thousands of protein domains, suggesting a basis for examining structurally related proteins. Finally, BioPlex, in combination with other approaches, can be used to reveal interactions of biological or clinical significance. For example, mutations in the membrane protein VAPB implicated in familial amyotrophic lateral sclerosis perturb a defined community of interactors. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. The BioPlex Network: A Systematic Exploration of the Human Interactome

    PubMed Central

    Huttlin, Edward L.; Ting, Lily; Bruckner, Raphael J.; Gebreab, Fana; Gygi, Melanie P.; Szpyt, John; Tam, Stanley; Zarraga, Gabriela; Colby, Greg; Baltier, Kurt; Dong, Rui; Guarani, Virginia; Vaites, Laura Pontano; Ordureau, Alban; Rad, Ramin; Erickson, Brian K.; Wühr, Martin; Chick, Joel; Zhai, Bo; Kolippakkam, Deepak; Mintseris, Julian; Obar, Robert A.; Harris, Tim; Artavanis-Tsakonas, Spyros; Sowa, Mathew E.; DeCamilli, Pietro; Paulo, Joao A.; Harper, J. Wade; Gygi, Steven P.

    2015-01-01

    SUMMARY Protein interactions form a network whose structure drives cellular function and whose organization informs biological inquiry. Using high-throughput affinity-purification mass spectrometry, we identify interacting partners for 2,594 human proteins in HEK293T cells. The resulting network (BioPlex) contains 23,744 interactions among 7,668 proteins with 86% previously undocumented. BioPlex accurately depicts known complexes, attaining 80-100% coverage for most CORUM complexes. The network readily subdivides into communities that correspond to complexes or clusters of functionally related proteins. More generally, network architecture reflects cellular localization, biological process, and molecular function, enabling functional characterization of thousands of proteins. Network structure also reveals associations among thousands of protein domains, suggesting a basis for examining structurally-related proteins. Finally, BioPlex, in combination with other approaches can be used to reveal interactions of biological or clinical significance. For example, mutations in the membrane protein VAPB implicated in familial Amyotrophic Lateral Sclerosis perturb a defined community of interactors. PMID:26186194

  18. Matching Crew Diet and Crop Food Production in BIO-Plex

    NASA Technical Reports Server (NTRS)

    Jones, Harry; Kwauk, Xianmin; Mead, Susan C. (Technical Monitor)

    2000-01-01

    This paper matches the BIO-Plex crop food production to the crew diet requirements. The expected average calorie requirement for BIO-Plex is 2,975 Calories per crewmember per day, for a randomly selected crew with a typical level of physical activity. The range of 2,550 to 3,400 Calories will cover about two-thirds of all crews. The exact calorie requirement will depend on the gender composition, individual weights, exercise, and work effort of the selected crew. The expected average crewmember calorie requirement can be met by 430 grams of carbohydrate, 100 grams of fat, and 90 grams of protein per crewmember per day, for a total of 620 grams. Some fat can replaced by carbohydrate. Each crewmember requires only 2 grams of vitamins and minerals per day. Only unusually restricted diets may lack essential nutrients. The Advanced Life Support (ALS) consensus is that BIO-Plex should grow wheat, potato, and soybean, and maybe sweet potato or peanut, and maybe lettuce and tomato. The BIO-Plex Biomass Production System food production and the external food supply must be matched to the crew diet requirement for calories and nutritional balance. The crop production and external supply specifications can each be varied as long as their sum matches the required diet specification. We have wide flexibility in choosing the crops and resupply. We can easily grow one-half the crew calories in one BIO-Plex Biomass Production Chamber (BPC) if we grow only the most productive crops (wheat, potato, and sweet potato) and it we achieve nominal crop productivity. If we assume higher productivity we can grow a wider variety of crops. If we grow one-half of the crew calories, externally supplied foods can easily provide the other half of the calories and balance the diet. We can not grow 95 percent of the crew calories in two BPCs at nominal productivity while growing a balanced diet. We produce maximum calories by growing wheat, potato, and peanut.

  19. Modeling of Solid Waste Processing Options in BIO-Plex

    NASA Technical Reports Server (NTRS)

    Rodriguez, Luis F.; Finn, Cory; Kang, Sukwon; Hogan, John; Luna, Bernadette (Technical Monitor)

    2000-01-01

    BIO-Plex is a ground-based test bed currently under development by NASA for testing technologies and practices that may be utilized in future long-term life support missions. All aspects of such an Advanced Life Support (ALS) System must be considered to confidently construct a reliable system, which will not only allow the crew to survive in harsh environments, but allow the crew time to perform meaningful research. Effective handling of solid wastes is a critical aspect of the system, especially when recovery of resources contained in the waste is required. This is particularly important for ALS Systems configurations that include a Biomass Production Chamber. In these cases, significant amounts of inedible biomass waste may be produced, which can ultimately serve as a repository of necessary resources for sustaining life, notably carbon, water, and plant nutrients. Numerous biological and physicochemical solid waste processing options have been considered. Biological options include composting, aerobic digestion, and anaerobic digestion. Physicochemical options include pyrolysis, SCWO (supercritical water oxidation), various incineration configurations, microwave incineration, magnetically assisted gasification, and low temperature plasma reaction. Modeling of these options is a necessary step to assist in the design process. A previously developed top-level model of BIO-Plex implemented in MATLAB Simulink (r) for the use of systems analysis and design has been adopted for this analysis. Presently, this model only considered incineration for solid waste processing. Present work, reported here, includes the expansion of this model to include a wider array of solid waste processing options selected from the above options, bearing in mind potential, near term solid waste treatment systems. Furthermore, a trade study has also been performed among these solid waste processing technologies in an effort to determine the ideal technology for long-term life support missions.

  20. Modeling Separate and Combined Atmospheres in BIO-Plex

    NASA Technical Reports Server (NTRS)

    Jones, Harry; Finn, Cory; Kwauk, Xianmin; Blackwell, Charles; Luna, Bernadette (Technical Monitor)

    2000-01-01

    We modeled BIO-Plex designs with separate or combined atmospheres and then simulated controlling the atmosphere composition. The BIO-Plex is the Bioregenerative Planetary Life Support Systems Test Complex, a large regenerative life support test facility under development at NASA Johnson Space Center. Although plants grow better at above-normal carbon dioxide levels, humans can tolerate even higher carbon dioxide levels. Incinerator exhaust has very high levels of carbon dioxide. An elaborate BIO-Plex design would maintain different atmospheres in the crew and plant chambers and isolate the incinerator exhaust in the airlock. This design easily controls the crew and plant carbon dioxide levels but it uses many gas processors, buffers, and controllers. If all the crew's food is grown inside BIO-Plex, all the carbon dioxide required by the plants is supplied by crew respiration and the incineration of plant and food waste. Because the oxygen mass flow must balance in a closed loop, the plants supply all the oxygen required by the crew and the incinerator. Using plants for air revitalization allows using fewer gas processors, buffers, and controllers. In the simplest design, a single combined atmosphere was used for the crew, the plant chamber, and the incinerator. All gas processors, buffers, and controllers were eliminated. The carbon dioxide levels were necessarily similar for the crew and plants. If most of the food is grown, carbon dioxide can be controlled at the desired level by scheduling incineration. An intermediate design uses one atmosphere for the crew and incinerator chambers and a second for the plant chamber. This allows different carbon dioxide levels for the crew and plants. Better control of the atmosphere is obtained by varying the incineration rate. Less gas processing storage and control is needed if more food is grown.

  1. Modeling Separate and Combined Atmospheres in BIO-Plex

    NASA Technical Reports Server (NTRS)

    Jones, Harry; Finn, Cory; Kwauk, Xian-Min; Blackwell, Charles; Luna, Bernadette (Technical Monitor)

    2000-01-01

    We modeled BIO-Plex designs with separate or combined atmospheres and then simulated controlling the atmosphere composition. The BIO-Plex is the Bioregenerative Planetary Life Support Systems Test Complex, a large regenerative life support test facility under development at NASA Johnson Space Center. Although plants grow better at above-normal carbon dioxide levels, humans can tolerate even higher carbon dioxide levels. incinerator exhaust has very high levels of carbon dioxide. An elaborate BIO-Plex design would maintain different atmospheres in the crew and plant chambers and isolate the incinerator exhaust in the airlock. This design easily controls the crew and plant carbon dioxide levels but it uses many gas processors, buffers, and controllers. If all the crew's food is grown inside BIO-Plex, all the carbon dioxide required by the plants is supplied by crew respiration and the incineration of plant and food waste. Because the oxygen mass flow must balance in a closed loop, the plants supply all the oxygen required by the crew and the incinerator. Using plants for air revitalization allows using fewer gas processors, buffers, and controllers. In the simplest design, a single combined atmosphere was used for the crew, the plant chamber, and the incinerator. All gas processors, buffers, and controllers were eliminated. The carbon dioxide levels were necessarily similar for the crew and plants. If most of the food is grown, carbon dioxide can be controlled at the desired level by scheduling incineration. An intermediate design uses one atmosphere for the crew and incinerator chambers and a second for the plant chamber. This allows different carbon dioxide levels for the crew and plants. Better control of the atmosphere is obtained by varying the incineration rate. Less gas processing, storage, and control is needed if more food is grown.

  2. Bioregenerative Planetary Life Support Systems Test Complex (BIO-Plex): NASA's Next Human-Rated Testing Facility

    NASA Technical Reports Server (NTRS)

    Tri, Terry O.

    1999-01-01

    As a key component in its ground test bed capability, NASA's Advanced Life Support Program has been developing a large-scale advanced life support test facility capable of supporting long-duration evaluations of integrated bioregenerative life support systems with human test crews. This facility-targeted for evaluation of hypogravity compatible life support systems to be developed for use on planetary surfaces such as Mars or the Moon-is called the Bioregenerative Planetary Life Support Systems Test Complex (BIO-Plex) and is currently under development at the Johnson Space Center. This test bed is comprised of a set of interconnected chambers with a sealed internal environment which are outfitted with systems capable of supporting test crews of four individuals for periods exceeding one year. The advanced technology systems to be tested will consist of both biological and physicochemical components and will perform all required crew life support functions. This presentation provides a description of the proposed test "missions" to be supported by the BIO-Plex and the planned development strategy for the facility.

  3. Effects of organic selenium and zinc on the aging process of laying hens

    USDA-ARS?s Scientific Manuscript database

    The objective of the study was to determine whether supplementing the diets of post-molted hens with organic selenium (Se) (Sel-Plex®) and/or organic Zinc (Zn) (Bio-Plex®) could improve laying hen performance. Prior to molting, 120-78 wk old laying hens were separated into four treatment groups of ...

  4. Whole Genome Amplification of Labeled Viable Single Cells Suited for Array-Comparative Genomic Hybridization.

    PubMed

    Kroneis, Thomas; El-Heliebi, Amin

    2015-01-01

    Understanding details of a complex biological system makes it necessary to dismantle it down to its components. Immunostaining techniques allow identification of several distinct cell types thereby giving an inside view of intercellular heterogeneity. Often staining reveals that the most remarkable cells are the rarest. To further characterize the target cells on a molecular level, single cell techniques are necessary. Here, we describe the immunostaining, micromanipulation, and whole genome amplification of single cells for the purpose of genomic characterization. First, we exemplify the preparation of cell suspensions from cultured cells as well as the isolation of peripheral mononucleated cells from blood. The target cell population is then subjected to immunostaining. After cytocentrifugation target cells are isolated by micromanipulation and forwarded to whole genome amplification. For whole genome amplification, we use GenomePlex(®) technology allowing downstream genomic analysis such as array-comparative genomic hybridization.

  5. High-throughput informative single nucleotide polymorphism-based typing of Neisseria gonorrhoeae using the Sequenom MassARRAY iPLEX platform.

    PubMed

    Trembizki, Ella; Smith, Helen; Lahra, Monica M; Chen, Marcus; Donovan, Basil; Fairley, Christopher K; Guy, Rebecca; Kaldor, John; Regan, David; Ward, James; Nissen, Michael D; Sloots, Theo P; Whiley, David M

    2014-06-01

    Neisseria gonorrhoeae antimicrobial resistance (AMR) is a global problem heightened by emerging resistance to ceftriaxone. Appropriate molecular typing methods are important for understanding the emergence and spread of N. gonorrhoeae AMR. We report on the development, validation and testing of a Sequenom MassARRAY iPLEX method for multilocus sequence typing (MLST)-style genotyping of N. gonorrhoeae isolates. An iPLEX MassARRAY method (iPLEX14SNP) was developed targeting 14 informative gonococcal single nucleotide polymorphisms (SNPs) previously shown to predict MLST types. The method was initially validated using 24 N. gonorrhoeae control isolates and was then applied to 397 test isolates collected throughout Queensland, Australia in the first half of 2012. The iPLEX14SNP method provided 100% accuracy for the control isolates, correctly identifying all 14 SNPs for all 24 isolates (336/336). For the 397 test isolates, the iPLEX14SNP assigned results for 5461 of the possible 5558 SNPs (SNP call rate 98.25%), with complete 14 SNP profiles obtained for 364 isolates. Based on the complete SNP profile data, there were 49 different sequence types identified in Queensland, with 11 of the 49 SNP profiles accounting for the majority (n = 280; 77%) of isolates. AMR was dominated by several geographically clustered sequence types. Using the iPLEX14SNP method, up to 384 isolates could be tested within 1 working day for less than Aus$10 per isolate. The iPLEX14SNP offers an accurate and high-throughput method for the MLST-style genotyping of N. gonorrhoeae and may prove particularly useful for large-scale studies investigating the emergence and spread of gonococcal AMR. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Protein Multiplexed Immunoassay Analysis with R.

    PubMed

    Breen, Edmond J

    2017-01-01

    Plasma samples from 177 control and type 2 diabetes patients collected at three Australian hospitals are screened for 14 analytes using six custom-made multiplex kits across 60 96-well plates. In total 354 samples were collected from the patients, representing one baseline and one end point sample from each patient. R methods and source code for analyzing the analyte fluorescence response obtained from these samples by Luminex Bio-Plex ® xMap multiplexed immunoassay technology are disclosed. Techniques and R procedures for reading Bio-Plex ® result files for statistical analysis and data visualization are also presented. The need for technical replicates and the number of technical replicates are addressed as well as plate layout design strategies. Multinomial regression is used to determine plate to sample covariate balance. Methods for matching clinical covariate information to Bio-Plex ® results and vice versa are given. As well as methods for measuring and inspecting the quality of the fluorescence responses are presented. Both fixed and mixed-effect approaches for immunoassay statistical differential analysis are presented and discussed. A random effect approach to outlier analysis and detection is also shown. The bioinformatics R methodology present here provides a foundation for rigorous and reproducible analysis of the fluorescence response obtained from multiplexed immunoassays.

  7. Hydroponics Database and Handbook for the Advanced Life Support Test Bed

    NASA Technical Reports Server (NTRS)

    Nash, Allen J.

    1999-01-01

    During the summer 1998, I did student assistance to Dr. Daniel J. Barta, chief plant growth expert at Johnson Space Center - NASA. We established the preliminary stages of a hydroponic crop growth database for the Advanced Life Support Systems Integration Test Bed, otherwise referred to as BIO-Plex (Biological Planetary Life Support Systems Test Complex). The database summarizes information from published technical papers by plant growth experts, and it includes bibliographical, environmental and harvest information based on plant growth under varying environmental conditions. I collected 84 lettuce entries, 14 soybean, 49 sweet potato, 16 wheat, 237 white potato, and 26 mix crop entries. The list will grow with the publication of new research. This database will be integrated with a search and systems analysis computer program that will cross-reference multiple parameters to determine optimum edible yield under varying parameters. Also, we have made preliminary effort to put together a crop handbook for BIO-Plex plant growth management. It will be a collection of information obtained from experts who provided recommendations on a particular crop's growing conditions. It includes bibliographic, environmental, nutrient solution, potential yield, harvest nutritional, and propagation procedure information. This handbook will stand as the baseline growth conditions for the first set of experiments in the BIO-Plex facility.

  8. Superhard Transparent Coatings

    DTIC Science & Technology

    1975-04-01

    alcohol has OH groups and polymethacrylic acid has carboxyl COOH groups. These form a clear suspension with the sub- micron hydrophilic particles...PHOSPHORIC ACID /SILICA/PVA 38 SYSTEM 3: ALON/POLYSILICIC ACID /BORACIC ACID 38 SYSTEM 4: ALON/SILICA/CYMEL - MOH HARDNESS VS...60 POLYSILICIC ACID 60 Methods for the Preparation of a Polystllcate/ Alon Suspension 61 Compositions 62 STRETCHED PLEX 63 OPTIMUM COMPOSITIONS

  9. A Comparison Between Publish-and-Subscribe and Client-Server Models in Distributed Control System Networks

    NASA Technical Reports Server (NTRS)

    Boulanger, Richard P., Jr.; Kwauk, Xian-Min; Stagnaro, Mike; Kliss, Mark (Technical Monitor)

    1998-01-01

    The BIO-Plex control system requires real-time, flexible, and reliable data delivery. There is no simple "off-the-shelf 'solution. However, several commercial packages will be evaluated using a testbed at ARC for publish- and-subscribe and client-server communication architectures. Point-to-point communication architecture is not suitable for real-time BIO-Plex control system. Client-server architecture provides more flexible data delivery. However, it does not provide direct communication among nodes on the network. Publish-and-subscribe implementation allows direct information exchange among nodes on the net, providing the best time-critical communication. In this work Network Data Delivery Service (NDDS) from Real-Time Innovations, Inc. ARTIE will be used to implement publish-and subscribe architecture. It offers update guarantees and deadlines for real-time data delivery. Bridgestone, a data acquisition and control software package from National Instruments, will be tested for client-server arrangement. A microwave incinerator located at ARC will be instrumented with a fieldbus network of control devices. BridgeVIEW will be used to implement an enterprise server. An enterprise network consisting of several nodes at ARC and a WAN connecting ARC and RISC will then be setup to evaluate proposed control system architectures. Several network configurations will be evaluated for fault tolerance, quality of service, reliability and efficiency. Data acquired from these network evaluation tests will then be used to determine preliminary design criteria for the BIO-Plex distributed control system.

  10. Human Engineering Operations and Habitability Assessment: A Process for Advanced Life Support Ground Facility Testbeds

    NASA Technical Reports Server (NTRS)

    Connolly, Janis H.; Arch, M.; Elfezouaty, Eileen Schultz; Novak, Jennifer Blume; Bond, Robert L. (Technical Monitor)

    1999-01-01

    Design and Human Engineering (HE) processes strive to ensure that the human-machine interface is designed for optimal performance throughout the system life cycle. Each component can be tested and assessed independently to assure optimal performance, but it is not until full integration that the system and the inherent interactions between the system components can be assessed as a whole. HE processes (which are defining/app lying requirements for human interaction with missions/systems) are included in space flight activities, but also need to be included in ground activities and specifically, ground facility testbeds such as Bio-Plex. A unique aspect of the Bio-Plex Facility is the integral issue of Habitability which includes qualities of the environment that allow humans to work and live. HE is a process by which Habitability and system performance can be assessed.

  11. Architecture of the human interactome defines protein communities and disease networks

    PubMed Central

    Huttlin, Edward L.; Bruckner, Raphael J.; Paulo, Joao A.; Cannon, Joe R.; Ting, Lily; Baltier, Kurt; Colby, Greg; Gebreab, Fana; Gygi, Melanie P.; Parzen, Hannah; Szpyt, John; Tam, Stanley; Zarraga, Gabriela; Pontano-Vaites, Laura; Swarup, Sharan; White, Anne E.; Schweppe, Devin K.; Rad, Ramin; Erickson, Brian K.; Obar, Robert A.; Guruharsha, K.G.; Li, Kejie; Artavanis-Tsakonas, Spyros; Gygi, Steven P.; Harper, J. Wade

    2017-01-01

    The physiology of a cell can be viewed as the product of thousands of proteins acting in concert to shape the cellular response. Coordination is achieved in part through networks of protein-protein interactions that assemble functionally related proteins into complexes, organelles, and signal transduction pathways. Understanding the architecture of the human proteome has the potential to inform cellular, structural, and evolutionary mechanisms and is critical to elucidation of how genome variation contributes to disease1–3. Here, we present BioPlex 2.0 (Biophysical Interactions of ORFEOME-derived complexes), which employs robust affinity purification-mass spectrometry (AP-MS) methodology4 to elucidate protein interaction networks and co-complexes nucleated by more than 25% of protein coding genes from the human genome, and constitutes the largest such network to date. With >56,000 candidate interactions, BioPlex 2.0 contains >29,000 previously unknown co-associations and provides functional insights into hundreds of poorly characterized proteins while enhancing network-based analyses of domain associations, subcellular localization, and co-complex formation. Unsupervised Markov clustering (MCL)5 of interacting proteins identified more than 1300 protein communities representing diverse cellular activities. Genes essential for cell fitness6,7 are enriched within 53 communities representing central cellular functions. Moreover, we identified 442 communities associated with more than 2000 disease annotations, placing numerous candidate disease genes into a cellular framework. BioPlex 2.0 exceeds previous experimentally derived interaction networks in depth and breadth, and will be a valuable resource for exploring the biology of incompletely characterized proteins and for elucidating larger-scale patterns of proteome organization. PMID:28514442

  12. Mathematical Modeling of Food Supply for Long Term Space Missions Using Advanced Life Support

    NASA Technical Reports Server (NTRS)

    Cruthirds, John E.

    2003-01-01

    A habitat for long duration missions which utilizes Advanced Life Support (ALS), the Bioregenerative Planetary Life Support Systems Test Complex (BIO-Plex), is currently being built at JSC. In this system all consumables will be recycled and reused. In support of this effort, a menu is being planned utilizing ALS crops that will meet nutritional and psychological requirements. The need exists in the food system to identify specific physical quantities that define life support systems from an analysis and modeling perspective. Once these quantities are defined, they need to be fed into a mathematical model that takes into consideration other systems in the BIO-Plex. This model, if successful, will be used to understand the impacts of changes in the food system on the other systems and vice versa. The Equivalent System Mass (ESM) metric has been used to describe systems and subsystems, including the food system options, in terms of the single parameter, mass. There is concern that this approach might not adequately address the important issues of food quality and psychological impact on crew morale of a supply of fiesh food items. In fact, the mass of food can also depend on the quality of the food. This summer faculty fellow project will involve creating an appropriate mathematical model for the food plan developed by the Food Processing System for BIO-Plex. The desired outcome of this work will be a quantitative model that can be applied to the various options of supplying food on long-term space missions.

  13. Generation of miniaturized planar ecombinant antibody arrays using a microcantilever-based printer

    NASA Astrophysics Data System (ADS)

    Petersson, Linn; Berthet Duroure, Nathalie; Auger, Angèle; Dexlin-Mellby, Linda; Borrebaeck, Carl AK; Ait Ikhlef, Ali; Wingren, Christer

    2014-07-01

    Miniaturized (Ø 10 μm), multiplexed (>5-plex), and high-density (>100 000 spots cm-2) antibody arrays will play a key role in generating protein expression profiles in health and disease. However, producing such antibody arrays is challenging, and it is the type and range of available spotters which set the stage. This pilot study explored the use of a novel microspotting tool, BioplumeTM—consisting of an array of micromachined silicon cantilevers with integrated microfluidic channels—to produce miniaturized, multiplexed, and high-density planar recombinant antibody arrays for protein expression profiling which targets crude, directly labelled serum. The results demonstrated that 16-plex recombinant antibody arrays could be produced—based on miniaturized spot features (78.5 um2, Ø 10 μm) at a 7-125-times increased spot density (250 000 spots cm-2), interfaced with a fluorescent-based read-out. This prototype platform was found to display adequate reproducibility (spot-to-spot) and an assay sensitivity in the pM range. The feasibility of the array platform for serum protein profiling was outlined.

  14. Analysis of edible oil processing options for the BIO-Plex advanced life support system

    NASA Technical Reports Server (NTRS)

    Greenwalt, C. J.; Hunter, J.

    2000-01-01

    Edible oil is a critical component of the proposed plant-based Advanced Life Support (ALS) diet. Soybean, peanut, and single-cell oil are the oil source options to date. In terrestrial manufacture, oil is ordinarily extracted with hexane, an organic solvent. However, exposed solvents are not permitted in the spacecraft environment or in enclosed human tests by National Aeronautics and Space Administration due to their potential danger and handling difficulty. As a result, alternative oil-processing methods will need to be utilized. Preparation and recovery options include traditional dehulling, crushing, conditioning, and flaking, extrusion, pressing, water extraction, and supercritical extraction. These processing options were evaluated on criteria appropriate to the Advanced Life Support System and BIO-Plex application including: product quality, product stability, waste production, risk, energy needs, labor requirements, utilization of nonrenewable resources, usefulness of by-products, and versatility and mass of equipment to determine the most appropriate ALS edible oil-processing operation.

  15. Multiplexed Microsphere Suspension-Array Assay for Urine Mitochondrial DNA Typing by C-Stretch Length in Hypervariable Regions.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi

    2018-07-01

    The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.

  16. Development and Comparison of Two Assay Formats for Parallel Detection of Four Biothreat Pathogens by Using Suspension Microarrays

    PubMed Central

    Janse, Ingmar; Bok, Jasper M.; Hamidjaja, Raditijo A.; Hodemaekers, Hennie M.; van Rotterdam, Bart J.

    2012-01-01

    Microarrays provide a powerful analytical tool for the simultaneous detection of multiple pathogens. We developed diagnostic suspension microarrays for sensitive and specific detection of the biothreat pathogens Bacillus anthracis, Yersinia pestis, Francisella tularensis and Coxiella burnetii. Two assay chemistries for amplification and labeling were developed, one method using direct hybridization and the other using target-specific primer extension, combined with hybridization to universal arrays. Asymmetric PCR products for both assay chemistries were produced by using a multiplex asymmetric PCR amplifying 16 DNA signatures (16-plex). The performances of both assay chemistries were compared and their advantages and disadvantages are discussed. The developed microarrays detected multiple signature sequences and an internal control which made it possible to confidently identify the targeted pathogens and assess their virulence potential. The microarrays were highly specific and detected various strains of the targeted pathogens. Detection limits for the different pathogen signatures were similar or slightly higher compared to real-time PCR. Probit analysis showed that even a few genomic copies could be detected with 95% confidence. The microarrays detected DNA from different pathogens mixed in different ratios and from spiked or naturally contaminated samples. The assays that were developed have a potential for application in surveillance and diagnostics. PMID:22355407

  17. Development and comparison of two assay formats for parallel detection of four biothreat pathogens by using suspension microarrays.

    PubMed

    Janse, Ingmar; Bok, Jasper M; Hamidjaja, Raditijo A; Hodemaekers, Hennie M; van Rotterdam, Bart J

    2012-01-01

    Microarrays provide a powerful analytical tool for the simultaneous detection of multiple pathogens. We developed diagnostic suspension microarrays for sensitive and specific detection of the biothreat pathogens Bacillus anthracis, Yersinia pestis, Francisella tularensis and Coxiella burnetii. Two assay chemistries for amplification and labeling were developed, one method using direct hybridization and the other using target-specific primer extension, combined with hybridization to universal arrays. Asymmetric PCR products for both assay chemistries were produced by using a multiplex asymmetric PCR amplifying 16 DNA signatures (16-plex). The performances of both assay chemistries were compared and their advantages and disadvantages are discussed. The developed microarrays detected multiple signature sequences and an internal control which made it possible to confidently identify the targeted pathogens and assess their virulence potential. The microarrays were highly specific and detected various strains of the targeted pathogens. Detection limits for the different pathogen signatures were similar or slightly higher compared to real-time PCR. Probit analysis showed that even a few genomic copies could be detected with 95% confidence. The microarrays detected DNA from different pathogens mixed in different ratios and from spiked or naturally contaminated samples. The assays that were developed have a potential for application in surveillance and diagnostics.

  18. Developmental validation of the IrisPlex system: determination of blue and brown iris colour for forensic intelligence.

    PubMed

    Walsh, Susan; Lindenbergh, Alexander; Zuniga, Sofia B; Sijen, Titia; de Knijff, Peter; Kayser, Manfred; Ballantyne, Kaye N

    2011-11-01

    The IrisPlex system consists of a highly sensitive multiplex genotyping assay together with a statistical prediction model, providing users with the ability to predict blue and brown human eye colour from DNA samples with over 90% precision. This 'DNA intelligence' system is expected to aid police investigations by providing phenotypic information on unknown individuals when conventional DNA profiling is not informative. Falling within the new area of forensic DNA phenotyping, this paper describes the developmental validation of the IrisPlex assay following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines for the application of DNA-based eye colour prediction to forensic casework. The IrisPlex assay produces complete SNP genotypes with only 31pg of DNA, approximately six human diploid cell equivalents, and is therefore more sensitive than commercial STR kits currently used in forensics. Species testing revealed human and primate specificity for a complete SNP profile. The assay is capable of producing accurate results from simulated casework samples such as blood, semen, saliva, hair, and trace DNA samples, including extremely low quantity samples. Due to its design, it can also produce full profiles with highly degraded samples often found in forensic casework. Concordance testing between three independent laboratories displayed reproducible results of consistent levels on varying types of simulated casework samples. With such high levels of sensitivity, specificity, consistency and reliability, this genotyping assay, as a core part of the IrisPlex system, operates in accordance with SWGDAM guidelines. Furthermore, as we demonstrated previously, the IrisPlex eye colour prediction system provides reliable results without the need for knowledge on the bio-geographic ancestry of the sample donor. Hence, the IrisPlex system, with its model-based prediction probability estimation of blue and brown human eye colour, represents a useful tool for immediate application in accredited forensic laboratories, to be used for forensic intelligence in tracing unknown individuals from crime scene samples. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Whole genome amplification of DNA extracted from FFPE tissues.

    PubMed

    Bosso, Mira; Al-Mulla, Fahd

    2011-01-01

    Whole genome amplification systems were developed to meet the increasing research demands on DNA resources and to avoid DNA shortage. The technology enables amplification of nanogram amounts of DNA into microgram quantities and is increasingly used in the amplification of DNA from multiple origins such as blood, fresh frozen tissue, formalin-fixed paraffin-embedded tissues, saliva, buccal swabs, bacteria, and plant and animal sources. This chapter focuses on the use of GenomePlex(®) tissue Whole Genome Amplification Kit, to amplify DNA directly from archived tissue. In addition, this chapter documents our unique experience with the utilization of GenomePlex(®) amplified DNA using several molecular techniques including metaphase Comparative Genomic Hybridization, array Comparative Genomic Hybridization, and real-time quantitative polymerase chain reaction assays. GenomePlex(®) is a registered trademark of Rubicon Genomics Incorporation.

  20. Medical Management of Cutaneous Sulfur Mustard Injuries

    DTIC Science & Technology

    2009-01-01

    negative pressure, (2) Amino-Plex® Spray (biO2 Cosmeceuticals International, Inc., Beverly Hills, CA), a nutritive cosmeceutical product that is...Inc., Beverly Hills, CA) is a nutritive cosmeceutical product that is designed to increase oxygen in cells, stimulate ATP synthesis, improve glucose... nutritive cosmeceutical product that is esigned to increase oxygen in cells, stimulate ATP synthesis, mprove glucose transportation, stimulate

  1. Comparison of two automated instruments for Epstein-Barr virus serology in a large adult hospital and implementation of an Epstein-Barr virus nuclear antigen-based testing algorithm.

    PubMed

    Al Sidairi, Hilal; Binkhamis, Khalifa; Jackson, Colleen; Roberts, Catherine; Heinstein, Charles; MacDonald, Jimmy; Needle, Robert; Hatchette, Todd F; LeBlanc, Jason J

    2017-11-01

    Serology remains the mainstay for diagnosis of Epstein-Barr virus (EBV) infection. This study compared two automated platforms (BioPlex 2200 and Architect i2000SR) to test three EBV serological markers: viral capsid antigen (VCA) immunoglobulins of class M (IgM), VCA immunoglobulins of class G (IgG) and EBV nuclear antigen-1 (EBNA-1) IgG. Using sera from 65 patients at various stages of EBV disease, BioPlex demonstrated near-perfect agreement for all EBV markers compared to a consensus reference. The agreement for Architect was near-perfect for VCA IgG and EBNA-1 IgG, and substantial for VCA IgM despite five equivocal results. Since the majority of testing in our hospital was from adults with EBNA-1 IgG positive results, post-implementation analysis of an EBNA-based algorithm showed advantages over parallel testing of the three serologic markers. This small verification demonstrated that both automated systems for EBV serology had good performance for all EBV markers, and an EBNA-based testing algorithm is ideal for an adult hospital.

  2. 78 FR 70617 - In the Matter of Pure H20 Bio-Technologies, Inc.; Order of Suspension of Trading

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of Pure H20 Bio-Technologies, Inc.; Order of Suspension of Trading November 22, 2013. It appears to the Securities and Exchange Commission that there is a lack of current and accurate information concerning the securities of Pure H20 Bio...

  3. Efficient screening of environmental isolates for Saccharomyces cerevisiae strains that are suitable for brewing.

    PubMed

    Fujihara, Hidehiko; Hino, Mika; Takashita, Hideharu; Kajiwara, Yasuhiro; Okamoto, Keiko; Furukawa, Kensuke

    2014-01-01

    We developed an efficient screening method for Saccharomyces cerevisiae strains from environmental isolates. MultiPlex PCR was performed targeting four brewing S. cerevisiae genes (SSU1, AWA1, BIO6, and FLO1). At least three genes among the four were amplified from all S. cerevisiae strains. The use of this method allowed us to successfully obtain S. cerevisiae strains.

  4. Bioregenerative Life Support Systems Test Complex (Bio-Plex) Food Processing System: A Dual System

    NASA Technical Reports Server (NTRS)

    Perchonok, Michele; Vittadini, Elena; Peterson, Laurie J.; Swango, Beverly E.; Toerne, Mary E.; Russo, Dane M. (Technical Monitor)

    2001-01-01

    A Bioregenerative Life Support Test Complex, BIO-Plex, is currently being constructed at the Johnson Space Center (JSC) in Houston, TX. This facility will attempt to answer the questions involved in developing a lunar or planetary base. The Food Processing System (FPS) of the BIO-Plex is responsible for supplying food to the crew in coordination with the chosen mission scenario. Long duration space missions require development of both a Transit Food System and of a Lunar or Planetary Food System. These two systems are intrinsically different since the first one will be utilized in the transit vehicle in microgravity conditions with mostly resupplied foods, while the second will be used in conditions of partial gravity (hypogravity) to process foods from crops grown in the facility. The Transit Food System will consist of prepackaged food of extended shelf life. It will be supplemented with salad crops that will be consumed fresh. Microgravity imposes significant limitation on the ability to handle food and allows only for minimal processing. The challenge is to develop food systems similar to the International Space Station or Shuttle Food Systems but with a shelf life of 3 - 5 years. The Lunar or Planetary Food System will allow for food processing of crops due to the presence of some gravitational force (1/6 to 1/3 that of Earth). Crops such as wheat, soybean, rice, potato, peanut, and salad crops, will be processed to final products to provide a nutritious and acceptable diet for the crew. Not only are constraints imposed on the FPS from the crops (e.g., crop variation, availability, storage and shelf-life) but also significant requirements are present for the crew meals (e.g., RDA, high quality, safety, variety). The FPS becomes a fulcrum creating the right connection from crops to crew meals while dealing with issues of integration within a closed self-regenerative system (e.g., safe processing, waste production, volumes, air contaminations, water usage, etc.). Options for the first test, for duration of 120 days, currently scheduled for late 2003 are outlined.

  5. Broad-Range Direct Detection and Identification of Fungi by Use of the PLEX-ID PCR-Electrospray Ionization Mass Spectrometry (ESI-MS) System

    PubMed Central

    Simner, Patricia J.; Uhl, James R.; Hall, Leslie; Weber, Michelle M.; Walchak, Robert C.; Buckwalter, Seanne

    2013-01-01

    The PLEX-ID system is a novel technology that couples PCR amplification and electrospray ionization-mass spectrometry to identify pathogens directly in clinical specimens. The analytical performance of the PLEX-ID Broad Fungal assay was compared with that of traditional culture identification by using 91 characterized fungal culture isolates (64 manufacturer-claimed and 27 nonclaimed organisms) and directly by using 395 respiratory specimens. Discordant results were resolved by D2 large-subunit ribosomal DNA fungal sequencing. Environmental studies were performed to monitor for potential contamination. The PLEX-ID Broad Fungal assay correctly identified 95.6% (87/91) and 81.3% (74/91) of the culture isolates to the genus and species levels, respectively. Of the manufacturer-claimed organisms, 100% (64/64) and 92.2% (59/64) were correctly identified to the genus and species levels, respectively. Direct analysis of respiratory specimens resulted in 67.6% (267/395) and 66.6% (263/395) agreement with culture results to the genus and species levels, respectively, with 16.2% (64/395) of the results discordant with culture and 16.2% (64/395) not detected by the system. The majority (>95%) of the isolates not detected directly by the PLEX-ID system ultimately grew in low quantities in culture (≤20 colonies). In 20.3% (35/172) of the respiratory specimens where no growth was observed in culture, the PLEX-ID system identified a fungus, suggesting a potential increase in sensitivity over culture in some instances. The PLEX-ID system provides a rapid method for the detection of a broad array of fungi directly in respiratory specimens and has the potential of impacting turnaround times and patient care by reducing the need to wait for the growth of an organism in culture. PMID:23515540

  6. Natural and cross-inducible anti-SIV antibodies in Mauritian cynomolgus macaques

    PubMed Central

    Li, Hongzhao; Nykoluk, Mikaela; Li, Lin; Liu, Lewis R.; Omange, Robert W.; Soule, Geoff; Schroeder, Lukas T.; Toledo, Nikki; Kashem, Mohammad Abul; Correia-Pinto, Jorge F.; Liang, Binhua; Schultz-Darken, Nancy; Alonso, Maria J.; Whitney, James B.; Plummer, Francis A.

    2017-01-01

    Cynomolgus macaques are an increasingly important nonhuman primate model for HIV vaccine research. SIV-free animals without pre-existing anti-SIV immune responses are generally needed to evaluate the effect of vaccine-induced immune responses against the vaccine epitopes. Here, in order to select such animals for vaccine studies, we screened 108 naïve female Mauritian cynomolgus macaques for natural (baseline) antibodies to SIV antigens using a Bio-Plex multiplex system. The antigens included twelve 20mer peptides overlapping the twelve SIV protease cleavage sites (-10/+10), respectively (PCS peptides), and three non-PCS Gag or Env peptides. Natural antibodies to SIV antigens were detected in subsets of monkeys. The antibody reactivity to SIV was further confirmed by Western blot using purified recombinant SIV Gag and Env proteins. As expected, the immunization of monkeys with PCS antigens elicited anti-PCS antibodies. However, unexpectedly, antibodies to non-PCS peptides were also induced, as shown by both Bio-Plex and Western blot analyses, while the non-PCS peptides do not share sequence homology with PCS peptides. The presence of natural and vaccine cross-inducible SIV antibodies in Mauritian cynomolgus macaques should be considered in animal selection, experimental design and result interpretation, for their best use in HIV vaccine research. PMID:28982126

  7. BIO-Plex Information System Concept

    NASA Technical Reports Server (NTRS)

    Jones, Harry; Boulanger, Richard; Arnold, James O. (Technical Monitor)

    1999-01-01

    This paper describes a suggested design for an integrated information system for the proposed BIO-Plex (Bioregenerative Planetary Life Support Systems Test Complex) at Johnson Space Center (JSC), including distributed control systems, central control, networks, database servers, personal computers and workstations, applications software, and external communications. The system will have an open commercial computing and networking, architecture. The network will provide automatic real-time transfer of information to database server computers which perform data collection and validation. This information system will support integrated, data sharing applications for everything, from system alarms to management summaries. Most existing complex process control systems have information gaps between the different real time subsystems, between these subsystems and central controller, between the central controller and system level planning and analysis application software, and between the system level applications and management overview reporting. An integrated information system is vitally necessary as the basis for the integration of planning, scheduling, modeling, monitoring, and control, which will allow improved monitoring and control based on timely, accurate and complete data. Data describing the system configuration and the real time processes can be collected, checked and reconciled, analyzed and stored in database servers that can be accessed by all applications. The required technology is available. The only opportunity to design a distributed, nonredundant, integrated system is before it is built. Retrofit is extremely difficult and costly.

  8. Quantification and characterization of volatiles evolved during extrusion of rice and soy flours.

    PubMed

    Vodovotz, Y; Zasypkin, D; Lertsiriyothin, W; Lee, T C; Bourland, C T

    2000-01-01

    NASA-Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long-duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice, and wheat) may be a central feature of a biologically based Advanced Life Support System. To convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate and reach toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture, and triplicate samples were extruded using a tabletop single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMACs). Results showed a combination of alcohols, aldehydes, ketones, and carbonyl compounds in the different flours. Each compound and its SMAC value, as well as its impact on the air revitalization system, was discussed.

  9. Quantification and characterization of volatiles evolved during extrusion of rice and soy flours

    NASA Technical Reports Server (NTRS)

    Vodovotz, Y.; Zasypkin, D.; Lertsiriyothin, W.; Lee, T. C.; Bourland, C. T.

    2000-01-01

    NASA-Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long-duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice, and wheat) may be a central feature of a biologically based Advanced Life Support System. To convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate and reach toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture, and triplicate samples were extruded using a tabletop single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMACs). Results showed a combination of alcohols, aldehydes, ketones, and carbonyl compounds in the different flours. Each compound and its SMAC value, as well as its impact on the air revitalization system, was discussed.

  10. Improvement and automation of a real-time PCR assay for vaginal fluids.

    PubMed

    De Vittori, E; Giampaoli, S; Barni, F; Baldi, M; Berti, A; Ripani, L; Romano Spica, V

    2016-05-01

    The identification of vaginal fluids is crucial in forensic science. Several molecular protocols based on PCR amplification of mfDNA (microflora DNA) specific for vaginal bacteria are now available. Unfortunately mfDNA extraction and PCR reactions require manual optimization of several steps. The aim of present study was the verification of a partial automatization of vaginal fluids identification through two instruments widely diffused in forensic laboratories: EZ1 Advanced robot and Rotor Gene Q 5Plex HRM. Moreover, taking advantage of 5-plex thermocycler technology, the ForFluid kit performances were improved by expanding the mfDNA characterization panel with a new bacterial target for vaginal fluids and with an internal positive control (IPC) to monitor PCR inhibition. Results underlined the feasibility of a semi-automated extraction of mfDNA using a BioRobot and demonstrated the analytical improvements of the kit. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Improved palatability and bio-functionality of super-hard rice by soaking in a barley-koji miso suspension.

    PubMed

    Nakamura, Sumiko; Nakano, Yohei; Satoh, Hikaru; Ohtsubo, Ken'ichi

    2013-01-01

    Cooked grains of ae rice cultivars are too hard and non-sticky due to the presence of long-chain amylopectin, and ae rice cultivars are therefore called ``super-hard rice'' and cannot be used as table rice. However, they are promising in terms of their bio-functionality such as preventing diabetes. Miso (soybean paste) is a yeast-fermented food, made from steamed soybeans, salt, and inoculated cereals known as koji, made from rice, barley, or soybeans.We investigated the effects of soaking ae mutant rice cultivars in a miso suspension. Their chemical components, physical properties, and enzyme activities were measured under different conditions (milled rice before or after soaking in a 5% barley-koji miso suspension). Rice grains cooked after soaking in the miso suspension were less hard and more sticky than those cooked after soaking in water. Rice grains cooked after soaking in a 5% barley-koji miso suspension maintained high amounts of resistant starch and dietary fiber, and were fortified with polyphenols and isoflavones. Palatable and bio-functional ae rice could therefore be produced by cooking after soaking in a 5% barley-koji miso suspension.

  12. Quantification and Characterization of Volatiles Evolved During Extrusion of Rice and Soy Flours

    NASA Technical Reports Server (NTRS)

    Zasypkin, D.; Lertsiriyothin, W.; Lee, T. C.; Bourland, C. T.; Bond, Robert L. (Technical Monitor)

    1999-01-01

    NASA Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice and wheat) may be a central feature of a biological ly-based Advanced Life Support System (ALSS). In order to convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate reaching toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence, may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture and triplicate samples were extruded using a table top single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMAC). Results showed a combination of alcohols, aldehydes, ketones and carbonyl compounds in the different flours. Each compound and its SMAC value as well as its impact on the air revitalization system was discussed.

  13. Suspension arrays based on nanoparticle-encoded microspheres for high-throughput multiplexed detection

    PubMed Central

    Leng, Yuankui

    2017-01-01

    Spectrometrically or optically encoded microsphere based suspension array technology (SAT) is applicable to the high-throughput, simultaneous detection of multiple analytes within a small, single sample volume. Thanks to the rapid development of nanotechnology, tremendous progress has been made in the multiplexed detecting capability, sensitivity, and photostability of suspension arrays. In this review, we first focus on the current stock of nanoparticle-based barcodes as well as the manufacturing technologies required for their production. We then move on to discuss all existing barcode-based bioanalysis patterns, including the various labels used in suspension arrays, label-free platforms, signal amplification methods, and fluorescence resonance energy transfer (FRET)-based platforms. We then introduce automatic platforms for suspension arrays that use superparamagnetic nanoparticle-based microspheres. Finally, we summarize the current challenges and their proposed solutions, which are centered on improving encoding capacities, alternative probe possibilities, nonspecificity suppression, directional immobilization, and “point of care” platforms. Throughout this review, we aim to provide a comprehensive guide for the design of suspension arrays, with the goal of improving their performance in areas such as multiplexing capacity, throughput, sensitivity, and cost effectiveness. We hope that our summary on the state-of-the-art development of these arrays, our commentary on future challenges, and some proposed avenues for further advances will help drive the development of suspension array technology and its related fields. PMID:26021602

  14. A semi-automated multiplex high-throughput assay for measuring IgG antibodies against Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1) domains in small volumes of plasma.

    PubMed

    Cham, Gerald K K; Kurtis, Jonathan; Lusingu, John; Theander, Thor G; Jensen, Anja T R; Turner, Louise

    2008-06-12

    The level of antibodies against PfEMP1 is routinely quantified by the conventional microtitre enzyme-linked immunosorbent assay (ELISA). However, ELISA only measures one analyte at a time and requires a relatively large plasma volume if the complete antibody profile of the sample is to be obtained. Furthermore, assay-to-assay variation and the problem of storage of antigen can influence ELISA results. The bead-based assay described here uses the BioPlex100 (BioRad, Hercules, CA, USA) system which can quantify multiple antibodies simultaneously in a small plasma volume. A total of twenty nine PfEMP1 domains were PCR amplified from 3D7 genomic DNA, expressed in the Baculovirus system and purified by metal-affinity chromatography. The antibody reactivity level to the recombinant PfEMP1 proteins in human hyper-immune plasma was measured by ELISA. In parallel, these recombinant PfEMP1 proteins were covalently coupled onto beads each having its own unique detection signal and the human hyper-immune plasma reactivity was detected for each individual protein using a BioPlex100 system. Protein-coupled beads were analysed at two time points seven months apart, before and after lyophilization and the results compared to determine the effect of storage and lyophilization respectively on the beads. Multiplexed protein-coupled beads from twenty eight unique bead populations were evaluated on the BioPlex100 system against pooled human hyper-immune plasma before and after lyophilization. The bead-based assay was sensitive, accurate and reproducible. Four recombinant PfEMP1 proteins C17, D5, D9 and D12, selected on the basis that they showed a spread of median fluorescent intensity (MFI) values from low to high when analysed by the bead-based assay were analysed by ELISA and the results from both analyses were highly correlated. The Spearman's rank correlation coefficients (Rho) were > or = 0.86, (P < 0.0001) for all comparisons. Bead-based assays gave similar results regardless of whether they were performed on individual beads or on multiplexed beads; lyophilization had no impact on the assay performance. Spearman's rank correlation coefficients (Rho) were > or = 0.97, (P < 0.0001) for all comparisons. Importantly, the reactivity of protein-coupled non-lyophilized beads decreased with long term storage at 4 degrees C in the dark. Using this lyophilized multiplex assay, antibody reactivity levels to twenty eight different recombinant PfEMP1 proteins were simultaneously measured using a single microliter of plasma. Thus, the assay reported here provides a useful tool for rapid and efficient quantification of antibody reactivity against PfEMP1 variants in human plasma.

  15. A robust internal control for high-precision DNA methylation analyses by droplet digital PCR.

    PubMed

    Pharo, Heidi D; Andresen, Kim; Berg, Kaja C G; Lothe, Ragnhild A; Jeanmougin, Marine; Lind, Guro E

    2018-01-01

    Droplet digital PCR (ddPCR) allows absolute quantification of nucleic acids and has potential for improved non-invasive detection of DNA methylation. For increased precision of the methylation analysis, we aimed to develop a robust internal control for use in methylation-specific ddPCR. Two control design approaches were tested: (a) targeting a genomic region shared across members of a gene family and (b) combining multiple assays targeting different pericentromeric loci on different chromosomes. Through analyses of 34 colorectal cancer cell lines, the performance of the control assay candidates was optimized and evaluated, both individually and in various combinations, using the QX200™ droplet digital PCR platform (Bio-Rad). The best-performing control was tested in combination with assays targeting methylated CDO1 , SEPT9 , and VIM . A 4Plex panel consisting of EPHA3 , KBTBD4 , PLEKHF1 , and SYT10 was identified as the best-performing control. The use of the 4Plex for normalization reduced the variability in methylation values, corrected for differences in template amount, and diminished the effect of chromosomal aberrations. Positive Droplet Calling (PoDCall), an R-based algorithm for standardized threshold determination, was developed, ensuring consistency of the ddPCR results. Implementation of a robust internal control, i.e., the 4Plex, and an algorithm for automated threshold determination, PoDCall, in methylation-specific ddPCR increase the precision of DNA methylation analysis.

  16. Predictors of osteoclast activity in patients with sickle cell disease

    PubMed Central

    Nouraie, Mehdi; Cheng, Kevin; Niu, Xiaomei; Moore-King, Evadne; Fadojutimi-Akinsi, Margaret F.; Minniti, Caterina P.; Sable, Craig; Rana, Sohail; Dham, Niti; Campbell, Andrew; Ensing, Gregory; Kato, Gregory J.; Gladwin, Mark T.; Castro, Oswaldo L.; Gordeuk, Victor R.

    2011-01-01

    Background Bone changes are common in sickle cell disease, but the pathogenesis is not fully understood. Tartrate-resistant acid phosphatase (TRACP) type 5b is produced by bone-resorbing osteoclasts. In other forms of hemolytic anemia, increased iron stores are associated with osteoporosis. We hypothesized that transfusional iron overload would be associated with increased osteoclast activity in patients with sickle cell disease. Design and Methods We examined tartrate-resistant acid phosphatase 5b concentrations in patients with sickle cell disease and normal controls of similar age and sex distribution at steady state. Serum tartrate-resistant acid phosphatase 5b concentration was measured using an immunocapture enzyme assay and plasma concentrations of other cytokines were assayed using the Bio-Plex suspension array system. Tricuspid regurgitation velocity, an indirect measure of systolic pulmonary artery pressure, was determined by echocardiography. Results Tartrate-resistant acid phosphatase 5b concentrations were higher in 58 adults with sickle cell disease than in 22 controls (medians of 4.4 versus 2.4 U/L, respectively; P=0.0001). Among the patients with sickle cell disease, tartrate-resistant acid phosphatase 5b independently correlated with blood urea nitrogen (standardized beta=0.40, P=0.003), interleukin-8 (standardized beta=0.30, P=0.020), and chemokine C-C motif ligand 5 (standardized beta=−0.28, P=0.031) concentrations, but not with serum ferritin concentration. Frequent blood transfusions (>10 units in life time) were not associated with higher tartrate-resistant acid phosphatase 5b levels in multivariate analysis. There were strong correlations among tartrate-resistant acid phosphatase 5b, alkaline phosphatase and tricuspid regurgitation velocity (r>0.35, P<0.001). Conclusions Patients with sickle cell disease have increased osteoclast activity as reflected by serum tartrate-resistant acid phosphatase 5b concentrations. Our results may support a potential role of inflammation rather than increased iron stores in stimulating osteoclast activity in sickle cell disease. The positive relationships among tartrate-resistant acid phosphatase 5b, alkaline phosphatase and tricuspid regurgitation velocity raise the possibility of a common pathway in the pulmonary and bone complications of sickle cell disease. PMID:21546502

  17. Design and operation of a portable scanner for high performance microchip capillary array electrophoresis.

    PubMed

    Scherer, James R; Liu, Peng; Mathies, Richard A

    2010-11-01

    We have developed a compact, laser-induced fluorescence detection scanner, the multichannel capillary array electrophoresis portable scanner (McCAEPs) as a platform for electrophoretic detection and control of high-throughput, integrated microfluidic devices for genetic and other analyses. The instrument contains a confocal optical system with a rotary objective for detecting four different fluorescence signals, a pneumatic system consisting of two pressure/vacuum pumps and 28 individual addressable solenoid valves for control of on-chip microvalves and micropumps, four Polymerase Chain Reaction (PCR) temperature control systems, and four high voltage power supplies for electrophoresis. The detection limit of the instrument is ~20 pM for on-chip capillary electrophoresis of fluorescein dyes. To demonstrate the system performance for forensic short tandem repeat (STR) analysis, two experiments were conducted: (i) electrophoretic separation and detection of STR samples on a 96-lane microfabricated capillary array electrophoresis microchip. Fully resolved PowerPlex(®) 16 STR profiles amplified from 1 ng of 9947A female standard DNA were successfully obtained; (ii) nine-plex STR amplification, sample injection, separation, and fluorescence detection of 100-copy 9948 male standard DNA in a single integrated PCR- capillary electrophoresis microchip. These results demonstrate that the McCAEPs can be used as a versatile control and detection instrument that operates integrated microfluidic devices for high-performance forensic human identification.

  18. Design and operation of a portable scanner for high performance microchip capillary array electrophoresis

    NASA Astrophysics Data System (ADS)

    Scherer, James R.; Liu, Peng; Mathies, Richard A.

    2010-11-01

    We have developed a compact, laser-induced fluorescence detection scanner, the multichannel capillary array electrophoresis portable scanner (McCAEPs) as a platform for electrophoretic detection and control of high-throughput, integrated microfluidic devices for genetic and other analyses. The instrument contains a confocal optical system with a rotary objective for detecting four different fluorescence signals, a pneumatic system consisting of two pressure/vacuum pumps and 28 individual addressable solenoid valves for control of on-chip microvalves and micropumps, four Polymerase Chain Reaction (PCR) temperature control systems, and four high voltage power supplies for electrophoresis. The detection limit of the instrument is ˜20 pM for on-chip capillary electrophoresis of fluorescein dyes. To demonstrate the system performance for forensic short tandem repeat (STR) analysis, two experiments were conducted: (i) electrophoretic separation and detection of STR samples on a 96-lane microfabricated capillary array electrophoresis microchip. Fully resolved PowerPlex® 16 STR profiles amplified from 1 ng of 9947A female standard DNA were successfully obtained; (ii) nine-plex STR amplification, sample injection, separation, and fluorescence detection of 100-copy 9948 male standard DNA in a single integrated PCR- capillary electrophoresis microchip. These results demonstrate that the McCAEPs can be used as a versatile control and detection instrument that operates integrated microfluidic devices for high-performance forensic human identification.

  19. Analysis of Reproducibility of Proteome Coverage and Quantitation Using Isobaric Mass Tags (iTRAQ and TMT).

    PubMed

    Casey, Tammy M; Khan, Javed M; Bringans, Scott D; Koudelka, Tomas; Takle, Pari S; Downs, Rachael A; Livk, Andreja; Syme, Robert A; Tan, Kar-Chun; Lipscombe, Richard J

    2017-02-03

    This study aimed to compare the depth and reproducibility of total proteome and differentially expressed protein coverage in technical duplicates and triplicates using iTRAQ 4-plex, iTRAQ 8-plex, and TMT 6-plex reagents. The analysis was undertaken because comprehensive comparisons of isobaric mass tag reproducibility have not been widely reported in the literature. The highest number of proteins was identified with 4-plex, followed by 8-plex and then 6-plex reagents. Quantitative analyses revealed that more differentially expressed proteins were identified with 4-plex reagents than 8-plex reagents and 6-plex reagents. Replicate reproducibility was determined to be ≥69% for technical duplicates and ≥57% for technical triplicates. The results indicate that running an 8-plex or 6-plex experiment instead of a 4-plex experiment resulted in 26 or 39% fewer protein identifications, respectively. When 4-plex spectra were searched with three software tools-ProteinPilot, Mascot, and Proteome Discoverer-the highest number of protein identifications were obtained with Mascot. The analysis of negative controls demonstrated the importance of running experiments as replicates. Overall, this study demonstrates the advantages of using iTRAQ 4-plex reagents over iTRAQ 8-plex and TMT 6-plex reagents, provides estimates of technical duplicate and triplicate reproducibility, and emphasizes the value of running replicate samples.

  20. Use of Bioregenerative Technologies for Advanced Life Support: Some Considerations for BIO-Plex and Related Testbeds

    NASA Technical Reports Server (NTRS)

    Wheeler, Raymond M.; Strayer, Richard F.

    1997-01-01

    A review of bioregenerative life support concepts is provided as a guide for developing ground-based testbeds for NASA's Advanced Life Support Program. Key among these concepts are the use of controlled environment plant culture for the production of food, oxygen, and clean water, and the use of bacterial bioreactors for degrading wastes and recycling nutrients. Candidate crops and specific bioreactor approaches are discussed based on experiences from the. Kennedy Space Center Advanced Life Support Breadboard Project, and a review of related literature is provided.

  1. SSC San Diego Biennial Review 2003. Command and Control

    DTIC Science & Technology

    2003-01-01

    systems. IMAT systems use scientific visualizations, three- dimensional graphics, and animations to illustrate com- plex physical interactions in mission...Again, interactive animations are used to explain underlying concepts. For exam- ple, for principles of beamforming using a phased array, a three...solve complex problems. Experts type natural language text, use mouse clicks to provide hints for explanation generation, and use mouse clicks to

  2. On-chip Magnetic Separation and Cell Encapsulation in Droplets

    NASA Astrophysics Data System (ADS)

    Chen, A.; Byvank, T.; Bharde, A.; Miller, B. L.; Chalmers, J. J.; Sooryakumar, R.; Chang, W.-J.; Bashir, R.

    2012-02-01

    The demand for high-throughput single cell assays is gaining importance because of the heterogeneity of many cell suspensions, even after significant initial sorting. These suspensions may display cell-to-cell variability at the gene expression level that could impact single cell functional genomics, cancer, stem-cell research and drug screening. The on-chip monitoring of individual cells in an isolated environment could prevent cross-contamination, provide high recovery yield and ability to study biological traits at a single cell level These advantages of on-chip biological experiments contrast to conventional methods, which require bulk samples that provide only averaged information on cell metabolism. We report on a device that integrates microfluidic technology with a magnetic tweezers array to combine the functionality of separation and encapsulation of objects such as immunomagnetically labeled cells or magnetic beads into pico-liter droplets on the same chip. The ability to control the separation throughput that is independent of the hydrodynamic droplet generation rate allows the encapsulation efficiency to be optimized. The device can potentially be integrated with on-chip labeling and/or bio-detection to become a powerful single-cell analysis device.

  3. Optical demodulation system for digitally encoded suspension array in fluoroimmunoassay

    NASA Astrophysics Data System (ADS)

    He, Qinghua; Li, Dongmei; He, Yonghong; Guan, Tian; Zhang, Yilong; Shen, Zhiyuan; Chen, Xuejing; Liu, Siyu; Lu, Bangrong; Ji, Yanhong

    2017-09-01

    A laser-induced breakdown spectroscopy and fluorescence spectroscopy-coupled optical system is reported to demodulate digitally encoded suspension array in fluoroimmunoassay. It takes advantage of the plasma emissions of assembled elemental materials to digitally decode the suspension array, providing a more stable and accurate recognition to target biomolecules. By separating the decoding procedure of suspension array and adsorption quantity calculation of biomolecules into two independent channels, the cross talk between decoding and label signals in traditional methods had been successfully avoided, which promoted the accuracy of both processes and realized more sensitive quantitative detection of target biomolecules. We carried a multiplexed detection of several types of anti-IgG to verify the quantitative analysis performance of the system. A limit of detection of 1.48×10-10 M was achieved, demonstrating the detection sensitivity of the optical demodulation system.

  4. 77 FR 72904 - In the Matter of HealthSport, Inc., Home Director, Inc., Home Theater Products International, Inc...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-06

    ... Jewelry Concepts, Inc.), and Huifeng Bio-Pharmaceutical Technology, Inc.; Order of Suspension of Trading... information concerning the securities of Huifeng Bio-Pharmaceutical Technology, Inc. because it has not filed...

  5. Quantum-dot-based suspension microarray for multiplex detection of lung cancer markers: preclinical validation and comparison with the Luminex xMAP® system

    NASA Astrophysics Data System (ADS)

    Bilan, Regina; Ametzazurra, Amagoia; Brazhnik, Kristina; Escorza, Sergio; Fernández, David; Uríbarri, María; Nabiev, Igor; Sukhanova, Alyona

    2017-03-01

    A novel suspension multiplex immunoassay for the simultaneous specific detection of lung cancer markers in bronchoalveolar lavage fluid (BALF) clinical samples based on fluorescent microspheres having different size and spectrally encoded with quantum dots (QDEM) was developed. The designed suspension immunoassay was validated for the quantitative detection of three lung cancer markers in BALF samples from 42 lung cancer patients and 10 control subjects. Tumor markers were detected through simultaneous formation of specific immune complexes consisting of a capture molecule, the target antigen, and biotinylated recognition molecule on the surface of the different QDEM in a mixture. The immune complexes were visualized by fluorescently labeled streptavidin and simultaneously analyzed using a flow cytometer. Preclinical validation of the immunoassay was performed and results were compared with those obtained using an alternative 3-plex immunoassay based on Luminex xMAP® technology, developed on classical organic fluorophores. The comparison showed that the QDEM and xMAP® assays yielded almost identical results, with clear discrimination between control and clinical samples. Thus, developed QDEM technology can become a good alternative to xMAP® assays permitting analysis of multiple protein biomarkers using conventional flow cytometers.

  6. Quantum-dot-based suspension microarray for multiplex detection of lung cancer markers: preclinical validation and comparison with the Luminex xMAP® system

    PubMed Central

    Bilan, Regina; Ametzazurra, Amagoia; Brazhnik, Kristina; Escorza, Sergio; Fernández, David; Uríbarri, María; Nabiev, Igor; Sukhanova, Alyona

    2017-01-01

    A novel suspension multiplex immunoassay for the simultaneous specific detection of lung cancer markers in bronchoalveolar lavage fluid (BALF) clinical samples based on fluorescent microspheres having different size and spectrally encoded with quantum dots (QDEM) was developed. The designed suspension immunoassay was validated for the quantitative detection of three lung cancer markers in BALF samples from 42 lung cancer patients and 10 control subjects. Tumor markers were detected through simultaneous formation of specific immune complexes consisting of a capture molecule, the target antigen, and biotinylated recognition molecule on the surface of the different QDEM in a mixture. The immune complexes were visualized by fluorescently labeled streptavidin and simultaneously analyzed using a flow cytometer. Preclinical validation of the immunoassay was performed and results were compared with those obtained using an alternative 3-plex immunoassay based on Luminex xMAP® technology, developed on classical organic fluorophores. The comparison showed that the QDEM and xMAP® assays yielded almost identical results, with clear discrimination between control and clinical samples. Thus, developed QDEM technology can become a good alternative to xMAP® assays permitting analysis of multiple protein biomarkers using conventional flow cytometers. PMID:28300171

  7. The HIrisPlex-S system for eye, hair and skin colour prediction from DNA: Introduction and forensic developmental validation.

    PubMed

    Chaitanya, Lakshmi; Breslin, Krystal; Zuñiga, Sofia; Wirken, Laura; Pośpiech, Ewelina; Kukla-Bartoszek, Magdalena; Sijen, Titia; Knijff, Peter de; Liu, Fan; Branicki, Wojciech; Kayser, Manfred; Walsh, Susan

    2018-07-01

    Forensic DNA Phenotyping (FDP), i.e. the prediction of human externally visible traits from DNA, has become a fast growing subfield within forensic genetics due to the intelligence information it can provide from DNA traces. FDP outcomes can help focus police investigations in search of unknown perpetrators, who are generally unidentifiable with standard DNA profiling. Therefore, we previously developed and forensically validated the IrisPlex DNA test system for eye colour prediction and the HIrisPlex system for combined eye and hair colour prediction from DNA traces. Here we introduce and forensically validate the HIrisPlex-S DNA test system (S for skin) for the simultaneous prediction of eye, hair, and skin colour from trace DNA. This FDP system consists of two SNaPshot-based multiplex assays targeting a total of 41 SNPs via a novel multiplex assay for 17 skin colour predictive SNPs and the previous HIrisPlex assay for 24 eye and hair colour predictive SNPs, 19 of which also contribute to skin colour prediction. The HIrisPlex-S system further comprises three statistical prediction models, the previously developed IrisPlex model for eye colour prediction based on 6 SNPs, the previous HIrisPlex model for hair colour prediction based on 22 SNPs, and the recently introduced HIrisPlex-S model for skin colour prediction based on 36 SNPs. In the forensic developmental validation testing, the novel 17-plex assay performed in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines, as previously shown for the 24-plex assay. Sensitivity testing of the 17-plex assay revealed complete SNP profiles from as little as 63 pg of input DNA, equalling the previously demonstrated sensitivity threshold of the 24-plex HIrisPlex assay. Testing of simulated forensic casework samples such as blood, semen, saliva stains, of inhibited DNA samples, of low quantity touch (trace) DNA samples, and of artificially degraded DNA samples as well as concordance testing, demonstrated the robustness, efficiency, and forensic suitability of the new 17-plex assay, as previously shown for the 24-plex assay. Finally, we provide an update to the publically available HIrisPlex website https://hirisplex.erasmusmc.nl/, now allowing the estimation of individual probabilities for 3 eye, 4 hair, and 5 skin colour categories from HIrisPlex-S input genotypes. The HIrisPlex-S DNA test represents the first forensically validated tool for skin colour prediction, and reflects the first forensically validated tool for simultaneous eye, hair and skin colour prediction from DNA. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Stability of biogenic metal(loid) nanomaterials related to the colloidal stabilization theory of chemical nanostructures.

    PubMed

    Piacenza, Elena; Presentato, Alessandro; Turner, Raymond J

    2018-02-25

    In the last 15 years, the exploitation of biological systems (i.e. plants, bacteria, mycelial fungi, yeasts, and algae) to produce metal(loid) (Me)-based nanomaterials has been evaluated as eco-friendly and a cost-effective alternative to the chemical synthesis processes. Although the biological mechanisms of biogenic Me-nanomaterial (Bio-Me-nanomaterials) production are not yet completely elucidated, a key advantage of such bio-nanostructures over those chemically synthesized is related to their natural thermodynamic stability, with several studies ascribed to the presence of an organic layer surrounding these Bio-Me-nanostructures. Different macromolecules (e.g. proteins, peptides, lipids, DNA, and polysaccharides) or secondary metabolites (e.g. flavonoids, terpenoids, glycosides, organic acids, and alkaloids) naturally produced by organisms have been indicated as main contributors to the stabilization of Bio-Me-nanostructures. Nevertheless, the chemical-physical mechanisms behind the ability of these molecules in providing stability to Bio-Me-nanomaterials are unknown. In this context, transposing the stabilization theory of chemically synthesized Me-nanomaterials (Ch-Me-nanomaterials) to biogenic materials can be used towards a better comprehension of macromolecules and secondary metabolites role as stabilizing agents of Bio-Me-nanomaterials. According to this theory, nanomaterials are generally featured by high thermodynamic instability in suspension, due to their high surface area and surface energy. This feature leads to the necessity to stabilize chemical nanostructures, even during or directly after their synthesis, through the development of (i) electrostatic, (ii) steric, or (iii) electrosteric interactions occurring between molecules and nanomaterials in suspension. Based on these three mechanisms, this review is focused on parallels between the stabilization of biogenic or chemical nanomaterials, suggesting which chemical-physical mechanisms may be involved in the natural stability of Bio-Me-nanomaterials. As a result, macromolecules such as DNA, polyphosphates and proteins may electrostatically interact with Bio-Me-nanomaterials in suspension through their charged moieties, showing the same properties of counterions in Ch-Me-nanostructure suspensions. Since several biomolecules (e.g. neutral lipids, nonionic biosurfactants, polysaccharides, and secondary metabolites) produced by metal(loid)-grown organisms can develop similar steric hindrance as compared to nonionic amphiphilic surfactants and block co-polymers generally used to sterically stabilize Ch-Me-nanomaterials. These biomolecules, most likely, are involved in the development of steric stabilization, because of their bulky structures. Finally, charged lipids and polysaccharides, ionic biosurfactants or proteins with amphiphilic properties can exert a dual effect (i.e. electrostatic and steric repulsion interactions) in the contest of Bio-Me-nanomaterials, leading to the high degree of stability observed.

  9. Multiplex quantification of four DNA targets in one reaction with Bio-Rad droplet digital PCR system for GMO detection

    NASA Astrophysics Data System (ADS)

    Dobnik, David; Štebih, Dejan; Blejec, Andrej; Morisset, Dany; Žel, Jana

    2016-10-01

    The advantages of the digital PCR technology are already well documented until now. One way to achieve better cost efficiency of the technique is to use it in a multiplexing strategy. Droplet digital PCR platforms, which include two fluorescence filters, support at least duplex reactions and with some developments and optimization higher multiplexing is possible. The present study not only shows a development of multiplex assays in droplet digital PCR, but also presents a first thorough evaluation of several parameters in such multiplex digital PCR. Two 4-plex assays were developed for quantification of 8 different DNA targets (7 genetically modified maize events and maize endogene). Per assay, two of the targets were labelled with one fluorophore and two with another. As current analysis software does not support analysis of more than duplex, a new R- and Shiny-based web application analysis tool (http://bit.ly/ddPCRmulti) was developed that automates the analysis of 4-plex results. In conclusion, the two developed multiplex assays are suitable for quantification of GMO maize events and the same approach can be used in any other field with a need for accurate and reliable quantification of multiple DNA targets.

  10. Multiplex quantification of four DNA targets in one reaction with Bio-Rad droplet digital PCR system for GMO detection.

    PubMed

    Dobnik, David; Štebih, Dejan; Blejec, Andrej; Morisset, Dany; Žel, Jana

    2016-10-14

    The advantages of the digital PCR technology are already well documented until now. One way to achieve better cost efficiency of the technique is to use it in a multiplexing strategy. Droplet digital PCR platforms, which include two fluorescence filters, support at least duplex reactions and with some developments and optimization higher multiplexing is possible. The present study not only shows a development of multiplex assays in droplet digital PCR, but also presents a first thorough evaluation of several parameters in such multiplex digital PCR. Two 4-plex assays were developed for quantification of 8 different DNA targets (7 genetically modified maize events and maize endogene). Per assay, two of the targets were labelled with one fluorophore and two with another. As current analysis software does not support analysis of more than duplex, a new R- and Shiny-based web application analysis tool (http://bit.ly/ddPCRmulti) was developed that automates the analysis of 4-plex results. In conclusion, the two developed multiplex assays are suitable for quantification of GMO maize events and the same approach can be used in any other field with a need for accurate and reliable quantification of multiple DNA targets.

  11. Surface engineering of nanoparticles in suspension for particle based bio-sensing

    PubMed Central

    Sen, Tapas; Bruce, Ian J.

    2012-01-01

    Surface activation of nanoparticles in suspension using amino organosilane has been carried out via strict control of a particle surface ad-layer of water using a simple but efficient protocol ‘Tri-phasic Reverse Emulsion’ (TPRE). This approach produced thin and ordered layers of particle surface functional groups which allowed the efficient conjugation of biomolecules. When used in bio-sensing applications, the resultant conjugates were highly efficient in the hybrid capture of complementary oligonucleotides and the detection of food borne microorganism. TPRE overcomes a number of fundamental problems associated with the surface modification of particles in aqueous suspension viz. particle aggregation, density and organization of resultant surface functional groups by controlling surface condensation of the aminosilane. The approach has potential for application in areas as diverse as nanomedicine, to food technology and industrial catalysis. PMID:22872809

  12. Viscosity of diluted suspensions of vegetal particles in water

    NASA Astrophysics Data System (ADS)

    Szydłowska, Adriana; Hapanowicz, Jerzy

    2017-10-01

    Viscosity and rheological behaviour of sewage as well as sludge are essential while designing apparatuses and operations employed in the sewage treatment process and its processing. With reference to these substances, the bio-suspensions samples of three size fractions ((i) 150÷212 μm, (ii) 106÷150 μm and (iii) below106 μm) of dry grass in water with solid volume fraction 8%, 10% and 11% were prepared. After twenty four hours prior to their preparation time, the suspension samples underwent rheometeric measurements with the use of a rotational rheometer with coaxial cylinders. On the basis of the obtained results, flow curves were plotted and described with both the power model and Herschel-Bulkley model. Moreover, the viscosity of the studied substances was determined that allowed to conclude that the studied bio-suspensions display features of viscoelastic fluids. The experimentally established viscosity was compared to the calculated one according to Manley and Manson equation, recommended in the literature. It occurred that the measured viscosity values substantially exceed the calculation viscosity values, even by 105 times. The observations suggest that it stems from water imbibition of fibrous vegetal particles, which causes their swelling and decreases the amount of liquid phase in the suspension.

  13. Implementation of a decoupled controller for a magnetic suspension system using electromagnets mounted in a planar array

    NASA Technical Reports Server (NTRS)

    Cox, D. E.; Groom, N. J.

    1994-01-01

    An implementation of a decoupled, single-input/single-output control approach for a large angle magnetic suspension test fixture is described. Numerical and experimental results are presented. The experimental system is a laboratory model large gap magnetic suspension system which provides five degree-of-freedom control of a cylindrical suspended element. The suspended element contains a core composed of permanent magnet material and is levitated above five electromagnets mounted in a planar array.

  14. Digital barcodes of suspension array using laser induced breakdown spectroscopy

    PubMed Central

    He, Qinghua; Liu, Yixi; He, Yonghong; Zhu, Liang; Zhang, Yilong; Shen, Zhiyuan

    2016-01-01

    We show a coding method of suspension array based on the laser induced breakdown spectroscopy (LIBS), which promotes the barcodes from analog to digital. As the foundation of digital optical barcodes, nanocrystals encoded microspheres are prepared with self-assembly encapsulation method. We confirm that digital multiplexing of LIBS-based coding method becomes feasible since the microsphere can be coded with direct read-out data of wavelengths, and the method can avoid fluorescence signal crosstalk between barcodes and analyte tags, which lead to overall advantages in accuracy and stability to current fluorescent multicolor coding method. This demonstration increases the capability of multiplexed detection and accurate filtrating, expanding more extensive applications of suspension array in life science. PMID:27808270

  15. Degradation of Jet and Missile Fuels by Aquatic Microbial Communities.

    DTIC Science & Technology

    1987-07-01

    and JP-9 resisted bio ’.,-Ork’-,"k when incubated with water/sediment suspensions collected from aquatic habitats. RJ - rCoIP9 were not toxic to the...polynuclear aromatic materials. These results support our observations (Reference 2) of rapid bio - degradation of many aromatic hydrocarbons but...minimal disturbance, and the residual oil content ot the sediment was deternined. In their case, very little bio - degradation of the oil occurreo

  16. Multiplex quantification of four DNA targets in one reaction with Bio-Rad droplet digital PCR system for GMO detection

    PubMed Central

    Dobnik, David; Štebih, Dejan; Blejec, Andrej; Morisset, Dany; Žel, Jana

    2016-01-01

    The advantages of the digital PCR technology are already well documented until now. One way to achieve better cost efficiency of the technique is to use it in a multiplexing strategy. Droplet digital PCR platforms, which include two fluorescence filters, support at least duplex reactions and with some developments and optimization higher multiplexing is possible. The present study not only shows a development of multiplex assays in droplet digital PCR, but also presents a first thorough evaluation of several parameters in such multiplex digital PCR. Two 4-plex assays were developed for quantification of 8 different DNA targets (7 genetically modified maize events and maize endogene). Per assay, two of the targets were labelled with one fluorophore and two with another. As current analysis software does not support analysis of more than duplex, a new R- and Shiny-based web application analysis tool (http://bit.ly/ddPCRmulti) was developed that automates the analysis of 4-plex results. In conclusion, the two developed multiplex assays are suitable for quantification of GMO maize events and the same approach can be used in any other field with a need for accurate and reliable quantification of multiple DNA targets. PMID:27739510

  17. Lecithin-based novel cationic nanocarriers (LeciPlex) I: fabrication, characterization and evaluation.

    PubMed

    Date, Abhijit A; Srivastava, Deepika; Nagarsenker, Mangal S; Mulherkar, Rita; Panicker, Lata; Aswal, Vinod; Hassan, Puthusserickal A; Steiniger, Frank; Thamm, Jana; Fahr, Alfred

    2011-10-01

    In the present investigation, the feasibility of fabricating novel self-assembled cationic nanocarriers (LeciPlex) containing cetyltrimethylammonium bromide (CTAB) or didodecyldimethylammonium bromide (DDAB) and soybean lecithin using pharmaceutically acceptable biocompatible solvents such as 2-Pyrrolidone (Soluphor P) and diethyleneglycol monoethyl ether (Transcutol) was established. The interaction between DDAB/CTAB and soybean lecithin in the nanocarriers was confirmed by differential scanning calorimetry and in vitro antimicrobial studies. The positive charge on the nanocarriers was confirmed by zeta potential analysis. Transmission electron microscopy analysis could not reveal sufficient information regarding the internal structure of the nanocarriers, whereas cryotransmission electron microscopy studies indicated that these novel nanocarriers have unilamellar structure. Small-angle neutron scattering studies confirmed interaction of cationic surfactant (DDAB) and lecithin in the nanocarriers and confirmed the presence of unilamellar nanostructures. Various hydrophobic drugs could be encapsulated in the CTAB/DDAB-based lecithin nanocarriers (CTAB-LeciPlex or DDAB-LeciPlex) irrespective of their difference in log p-values. In vitro antimicrobial studies on triclosan-loaded LeciPlex confirmed entrapment of triclosan in the nanocarriers. The ability of CTAB-LeciPlex and DDAB-LeciPlex to condense plasmid DNA was established using agarose gel electrophoresis. DDAB-LeciPlex could successfully transfect pDNA in HEK-293 cells indicating potential in gene delivery.

  18. Construction of a versatile SNP array for pyramiding useful genes of rice.

    PubMed

    Kurokawa, Yusuke; Noda, Tomonori; Yamagata, Yoshiyuki; Angeles-Shim, Rosalyn; Sunohara, Hidehiko; Uehara, Kanako; Furuta, Tomoyuki; Nagai, Keisuke; Jena, Kshirod Kumar; Yasui, Hideshi; Yoshimura, Atsushi; Ashikari, Motoyuki; Doi, Kazuyuki

    2016-01-01

    DNA marker-assisted selection (MAS) has become an indispensable component of breeding. Single nucleotide polymorphisms (SNP) are the most frequent polymorphism in the rice genome. However, SNP markers are not readily employed in MAS because of limitations in genotyping platforms. Here the authors report a Golden Gate SNP array that targets specific genes controlling yield-related traits and biotic stress resistance in rice. As a first step, the SNP genotypes were surveyed in 31 parental varieties using the Affymetrix Rice 44K SNP microarray. The haplotype information for 16 target genes was then converted to the Golden Gate platform with 143-plex markers. Haplotypes for the 14 useful allele are unique and can discriminate among all other varieties. The genotyping consistency between the Affymetrix microarray and the Golden Gate array was 92.8%, and the accuracy of the Golden Gate array was confirmed in 3 F2 segregating populations. The concept of the haplotype-based selection by using the constructed SNP array was proofed. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  19. Multiplex analysis of pro-inflammatory cytokines in serum of Actinobacillus pleuropneumoniae-infected pigs.

    PubMed

    Wyns, H; Croubels, S; Vandekerckhove, M; Demeyere, K; De Backer, P; Goddeeris, B M; Meyer, E

    2015-10-01

    Porcine pleuropneumonia is a severe respiratory disease caused by Actinobacillus (A.) pleuropneumoniae. The aim of the present study was to analyze serum samples of A. pleuropneumoniae-infected pigs for TNF-α, IL-1β and IL-6 using a cytometric bead array (CBA) 3-plex assay and additionally for IL-6 using ELISA. The CBA 3-plex assay was successfully validated for use in serum. The limits of detection varied between 0.012 and 0.333 ng/mL, and the inter- and inter-assay coefficients of variation were <5% and <10%, respectively. Increased levels were observed for all 3 cytokines following experimental infection with A. pleuropneumoniae. Mean peak concentrations of TNF-α and IL-6 were recorded at 12h and at 10h p.i., respectively. For IL-6, similar concentration-time profiles were observed with CBA and ELISA. It is proposed that this immuno-assay can be applied for the screening of immunomodulatory properties of drugs and vaccine adjuvants in infection, inflammation and vaccination. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Improvement for identification of heterophile antibody interference and AFP hook effect in immunoassays with multiplex suspension bead array system.

    PubMed

    Wang, Yajie; Yu, Jinsheng; Ren, Yuan; Liu, Li; Li, Haowen; Guo, Anchen; Shi, Congning; Fang, Fang; Juehne, Twyla; Yao, Jianer; Yang, Enhuan; Zhou, Xuelei; Kang, Xixiong

    2013-11-15

    A variety of immunoassays including multiplex suspension bead array have been developed for tumor marker detections; however, these assays could be compromised in their sensitivity and specificity by well-known heterophile antibody interference and hook effect. Using Luminex® multiplex suspension bead arrays, we modified protocols with two newly-developed solutions that can identify heterophile antibody interference and AFP hook effect. Effectiveness of the two solutions was assessed in serum samples from patients. Concentrations of 9 tumor markers in heterophile antibody positive samples assayed with Solution A, containing murine monoclonal antibodies and mouse serum, were significantly reduced when compared with those false high signals assayed without Solution A (all p<0.01). With incorporation of Solution H (fluorescent beads linked with AFP antigen), a new strategy for identification of AFP hook effect was established, and with this strategy AFP hook effect was identified effectively in serum samples with very high levels of AFP. Two proprietary solutions improve the identification of heterophile antibody interference and AFP hook effect. With these solutions, multiplex suspension bead arrays provide more reliable testing results in tumor marker detection where complex clinical serum samples are used. © 2013.

  1. Multiplexing of miniaturized planar antibody arrays for serum protein profiling--a biomarker discovery in SLE nephritis.

    PubMed

    Petersson, Linn; Dexlin-Mellby, Linda; Bengtsson, Anders A; Sturfelt, Gunnar; Borrebaeck, Carl A K; Wingren, Christer

    2014-06-07

    In the quest to decipher disease-associated biomarkers, miniaturized and multiplexed antibody arrays may play a central role in generating protein expression profiles, or protein maps, of crude serum samples. In this conceptual study, we explored a novel, 4-times larger pen design, enabling us to, in a unique manner, simultaneously print 48 different reagents (antibodies) as individual 78.5 μm(2) (10 μm in diameter) sized spots at a density of 38,000 spots cm(-2) using dip-pen nanolithography technology. The antibody array set-up was interfaced with a high-resolution fluorescent-based scanner for sensitive sensing. The performance and applicability of this novel 48-plex recombinant antibody array platform design was demonstrated in a first clinical application targeting SLE nephritis, a severe chronic autoimmune connective tissue disorder, as the model disease. To this end, crude, directly biotinylated serum samples were targeted. The results showed that the miniaturized and multiplexed array platform displayed adequate performance, and that SLE-associated serum biomarker panels reflecting the disease process could be deciphered, outlining the use of miniaturized antibody arrays for disease proteomics and biomarker discovery.

  2. Positive association between leptin serum levels and disease activity on endoscopy in inflammatory bowel disease: A case-control study

    PubMed Central

    Trejo-Vazquez, Fabiola; Garza-Veloz, Idalia; Villela-Ramirez, Gabriela Alejandra; Ortiz-Castro, Yolanda; Mauricio-Saucedo, Panfilo; Cardenas-Vargas, Edith; Diaz-Baez, Mariana; Cid-Baez, Miguel A.; Castañeda-Miranda, Rodrigo; Ortiz-Rodriguez, Jose Manuel; Solis-Sanchez, Luis Octavio; Martinez-Fierro, Margarita L.

    2018-01-01

    Inflammatory bowel disease (IBD) includes ulcerative colitis (UC), Crohn's disease (CD) and indeterminate colitis. As these subtypes of IBD display important differences in the behavior of the natural course of the disease, the identification of non-invasive markers for IBD is important. The aim of the present study was to evaluate the serum levels of 10 adipokines and their association with endoscopic activity in IBD. The 10-protein profile (C-peptide, ghrelin, gastric inhibitory polypeptide, glucagon-like peptide-1, glucagon, insulin, leptin, plasminogen activator inhibitor-1, resistin and visfatin) was evaluated using serum from 53 participants (23 UC and 11 CD patients, as well as 19 controls) from Zacatecas (Mexico) by using the Bio-Plex Pro Human Diabetes 10-Plex Panel (Bio-Rad Laboratories, Inc.). Compared with those in the controls, leptin levels were significantly lower in patients with IBD (P=4.9×10−4). In addition, serum leptin displayed differences between groups with and without disease activity on endoscopy (P<0.001). Among the study population, serum leptin levels of <5,494 pg/ml significantly increased the odds of IBD by 12.8-fold [odds ratio (OR)=12.8, 95% confidence interval (CI)=3.04–53.9, P=0.001]. In addition, patients with serum leptin levels of <2,498 pg/ml displayed 5.8-fold greater odds of disease activity on endoscopy among the study population (OR=5.8, 95% CI=1.52–22.4, P=0.013). No differences in the serum levels of the remaining proteins were identified between the groups. Among the study population, serum leptin was associated with an increased risk of IBD and with disease activity on endoscopy. Additional studies will be necessary to validate the use of leptin as a non-invasive biomarker of IBD severity. PMID:29545852

  3. Development and characterization of novel 8-plex DiLeu isobaric labels for quantitative proteomics and peptidomics

    PubMed Central

    Frost, Dustin C.; Greer, Tyler; Xiang, Feng; Liang, Zhidan; Li, Lingjun

    2015-01-01

    Rationale Relative quantification of proteins via their enzymatically digested peptide products determines disease biomarker candidate lists in discovery studies. Isobaric label-based strategies using TMT and iTRAQ allow for up to 10 samples to be multiplexed in one experiment, but their expense limits their use. The demand for cost-effective tagging reagents capable of multiplexing many samples led us to develop an 8-plex version of our isobaric labeling reagent, DiLeu. Methods The original 4-plex DiLeu reagent was extended to an 8-plex set by coupling isotopic variants of dimethylated leucine to an alanine balance group designed to offset the increasing mass of the label’s reporter group. Tryptic peptides from a single protein digest, a protein mixture digest, and Saccharomyces cerevisiae lysate digest were labeled with 8-plex DiLeu and analyzed via nanoLC-MS2 on a Q-Exactive Orbitrap mass spectrometer. Characteristics of 8-plex DiLeu-labeled peptides, including quantitative accuracy and fragmentation, were examined. Results An 8-plex set of DiLeu reagents with 1 Da-spaced reporters was synthesized at a yield of 36%. The average cost to label eight 100 μg peptide samples was calculated to be approximately $15. Normalized collision energy tests on the Q-Exactive revealed that a higher-energy collisional dissociation value of 27 generated the optimum number of high-quality spectral matches. Relative quantification of DiLeu-labeled peptides yielded normalized median ratios accurate to within 12% of their expected values. Conclusions Cost-effective 8-plex DiLeu reagents can be synthesized and applied to relative peptide and protein quantification. These labels increase the multiplexing capacity of our previous 4-plex implementation without requiring high-resolution instrumentation to resolve reporter ion signals. PMID:25981542

  4. Identification of neutrophil-derived proteases and angiotensin II as biomarkers of cancer cachexia

    PubMed Central

    Penafuerte, Claudia A; Gagnon, Bruno; Sirois, Jacinthe; Murphy, Jessica; MacDonald, Neil; Tremblay, Michel L

    2016-01-01

    Background: Cachexia is a metabolic disorder characterised by muscle wasting, diminished response to anti-cancer treatments and poor quality of life. Our objective was to identify blood-based biomarkers of cachexia in advanced cancer patients. Hence, we characterised the plasma cytokine and blood cell mRNA profiles of patients grouped in three cohorts: patients with cachexia, pre-cachexia (no cachexia but high CRP levels: ⩾5 mg l−1) and no cachexia (no cachexia and CRP: <5 mg l−1). Methods: A total of 122 newly diagnosed cancer patients with seven cancer types were studied prior to their initial therapy. Plasma levels of 22 cytokines were quantified using the bio-plex technology. mRNAs isolated from whole blood and expression profiles were determined by the chip array technology and Ingenuity Pathway Analysis (IPA) software. Results: In comparison with non-cachectic individuals, both pre-cachectic and cachectic patients showed an increase (⩾1.5-folds) in mRNA expression of neutrophil-derived proteases (NDPs) and significantly elevated angiotensin II (Ang II) (P=0.005 and P=0.02, respectively), TGFβ1 (P=0.042 and P<0.0001, respectively) and CRP (both P<0.0001) in the plasma. Moreover, cachectic patients displayed a significant increase in IL-6 (P=0.005), IL-8 (P=0.001) and absolute neutrophil counts (P=0.007). Conclusions: Ang II, TGFβ1, CRP and NDP are blood biomarkers for cancer cachexia. These findings contribute to early diagnosis and prevention of cachexia. PMID:26954714

  5. Novel Multiplex Oligonucleotide-Conjugated Bead Suspension Array for Rapid Identification of Enterovirus 71 Subgenogroups▿ §

    PubMed Central

    Wu, Y.; Tan, E. L.; Yeo, A.; Chan, K. P.; Nishimura, H.; Cardosa, M. J.; Poh, C. L.; Quak, S. H.; Chow, Vincent T.

    2011-01-01

    A high-throughput multiplex bead suspension array was developed for the rapid subgenogrouping of EV71 strains, based on single nucleotide polymorphisms observed within the VP1 region with a high sensitivity as low as 1 PFU. Of 33 viral isolates and 55 clinical samples, all EV71 strains were successfully detected and correctly subgenogrouped. PMID:21084510

  6. IVIG Versus PLEX in the Treatment of Worsening Myasthenia Gravis: What is the Evidence?: A Critically Appraised Topic.

    PubMed

    Dhawan, Priya S; Goodman, Brent P; Harper, Charles M; Bosch, Peter E; Hoffman-Snyder, Charlene R; Wellik, Kay E; Wingerchuk, Dean M; Demaerschalk, Bart M

    2015-05-01

    Immune therapies such as intravenous immunoglobulin (IVIG) and plasma exchange (PLEX) are first line in the treatment of worsening myasthenia gravis. Although PLEX is favored in myasthenic crisis, IVIG is increasingly used in exacerbations due to cost and ease of administration. To review and critically assess current evidence on the effects of IVIG and PLEX on functional outcomes in patients with worsening myasthenia gravis. A structured critical appraisal was conducted on the objective topic. This included a creation of a structured question based on a clinical scenario, comprehensive literature search, selection of evidence for review, and critical appraisal of selected evidence. Evidence was summarized and commentary provided. Participants included consultant and resident neurologists, a medical librarian, clinical epidemiologists, and content experts in the field of neuromuscular neurology. A single-blinded, randomized-controlled trial that compared IVIG and PLEX in 84 patients with worsening myasthenia gravis was selected for review. Primary outcome measure was functional status at 14 days after treatment, as assessed by the Quantitative Myasthenia Gravis Score. Change in Quantitative Myasthenia Gravis Score at day 14 for all subjects was 4.0, without statistically significant differences between IVIG and PLEX groups. IVIG and PLEX are equally effective in worsening myasthenia gravis. Treatment decisions may depend on several variables, including presence of respiratory distress, medical comorbidities, access to medication, and cost. PLEX will likely remain the treatment of choice in true myasthenic crisis.

  7. Matrilin-3 induction of IL-1 receptor antagonist is required for up-regulating collagen II and aggrecan and down-regulating ADAMTS-5 gene expression.

    PubMed

    Jayasuriya, Chathuraka T; Goldring, Mary B; Terek, Richard; Chen, Qian

    2012-09-11

    Deletion or mutation of the gene encoding the cartilage extracellular matrix (ECM) protein matrilin-3 (MATN3) results in the early onset of osteoarthritis (OA), suggesting chondroprotective properties of MATN3. To understand the mechanisms underlying these properties, we determined the effects of MATN3 protein on the expression of several key anabolic and catabolic genes involved in chondrocyte homeostasis, and the dependence of such regulation on the anti-inflammatory cytokine: IL-1 receptor antagonist (IL-1Ra). The effects of recombinant human (rh) MATN3 protein were examined in C28/I2 immortalized human chondrocytes, primary human chondrocytes (PHCs), and primary mouse chondrocytes (PMCs). Messenger RNA levels of IL-1Ra, COL2A1, ACAN, MMP-13, and ADAMTS-4 and -5 were determined using real-time RT-PCR. Knocking down IL-1Ra was achieved by siRNA gene silencing. IL-1Ra protein levels were quantified by ELISA and the Bio-Plex Suspension Array System. COL2A1 protein level was quantified using Western blot analysis. Statistic analysis was done using the two-tailed t-test or one-way ANOVA. rhMATN3 protein induced gene expression of IL-1Ra in C28/I2 cells, PHCs, and PMCs in a dose- and time-dependent manner. Treatment of C28/I2 cells and PHCs with MATN3 protein stimulated gene expression of COL2A1 and ACAN. Conversely, mRNA levels of COL2A1 and ACAN were decreased in MATN3 KO mice. MATN3 protein treatment inhibited IL-1β-induced MMP-13, ADAMTS-4 and ADAMTS-5 in C28/I2 cells and PHCs. Knocking down IL-1Ra abolished the MATN3-mediated stimulation of COL2A1 and ACAN and inhibition of ADAMTS-5, but had no effect on MATN3 inhibition of MMP-13 mRNA. Our findings point to a novel regulatory role of MATN3 in cartilage homeostasis due to its capacity to induce IL-1Ra, to upregulate gene expression of the major cartilage matrix components, and to downregulate the expression of OA-associated matrix-degrading proteinases in chondrocytes. The chondroprotective properties of endogenous MATN3 depend partly on its induction of IL-1Ra. Our findings raise a possibility to use rhMATN3 protein for anti-inflammatory and chondroprotective therapy.

  8. Fabrication of Composite Microneedle Array Electrode for Temperature and Bio-Signal Monitoring.

    PubMed

    Sun, Yiwei; Ren, Lei; Jiang, Lelun; Tang, Yong; Liu, Bin

    2018-04-13

    Body temperature and bio-signals are important health indicators that reflect the human health condition. However, monitoring these indexes is inconvenient and time-consuming, requires various instruments, and needs professional skill. In this study, a composite microneedle array electrode (CMAE) was designed and fabricated. It simultaneously detects body temperature and bio-signals. The CMAE consists of a 6 × 6 microneedles array with a height of 500 μm and a base diameter of 200 μm. Multiple insertion experiments indicate that the CMAE possesses excellent mechanical properties. The CMAE can pierce porcine skin 100 times without breaking or bending. A linear calibration relationship between temperature and voltage are experimentally obtained. Armpit temperature (35.8 °C) and forearm temperature (35.3 °C) are detected with the CMAE, and the measurements agree well with the data acquired with a clinical thermometer. Bio-signals including EII, ECG, and EMG are recorded and compared with those obtained by a commercial Ag/AgCl electrode. The CMAE continuously monitors bio-signals and is more convenient to apply because it does not require skin preparation and gel usage. The CMAE exhibits good potential for continuous and repetitive monitoring of body temperature and bio-signals.

  9. Fabrication of Composite Microneedle Array Electrode for Temperature and Bio-Signal Monitoring

    PubMed Central

    Sun, Yiwei; Ren, Lei; Jiang, Lelun; Tang, Yong; Liu, Bin

    2018-01-01

    Body temperature and bio-signals are important health indicators that reflect the human health condition. However, monitoring these indexes is inconvenient and time-consuming, requires various instruments, and needs professional skill. In this study, a composite microneedle array electrode (CMAE) was designed and fabricated. It simultaneously detects body temperature and bio-signals. The CMAE consists of a 6 × 6 microneedles array with a height of 500 μm and a base diameter of 200 μm. Multiple insertion experiments indicate that the CMAE possesses excellent mechanical properties. The CMAE can pierce porcine skin 100 times without breaking or bending. A linear calibration relationship between temperature and voltage are experimentally obtained. Armpit temperature (35.8 °C) and forearm temperature (35.3 °C) are detected with the CMAE, and the measurements agree well with the data acquired with a clinical thermometer. Bio-signals including EII, ECG, and EMG are recorded and compared with those obtained by a commercial Ag/AgCl electrode. The CMAE continuously monitors bio-signals and is more convenient to apply because it does not require skin preparation and gel usage. The CMAE exhibits good potential for continuous and repetitive monitoring of body temperature and bio-signals. PMID:29652837

  10. FamPlex: a resource for entity recognition and relationship resolution of human protein families and complexes in biomedical text mining.

    PubMed

    Bachman, John A; Gyori, Benjamin M; Sorger, Peter K

    2018-06-28

    For automated reading of scientific publications to extract useful information about molecular mechanisms it is critical that genes, proteins and other entities be correctly associated with uniform identifiers, a process known as named entity linking or "grounding." Correct grounding is essential for resolving relationships among mined information, curated interaction databases, and biological datasets. The accuracy of this process is largely dependent on the availability of machine-readable resources associating synonyms and abbreviations commonly found in biomedical literature with uniform identifiers. In a task involving automated reading of ∼215,000 articles using the REACH event extraction software we found that grounding was disproportionately inaccurate for multi-protein families (e.g., "AKT") and complexes with multiple subunits (e.g."NF- κB"). To address this problem we constructed FamPlex, a manually curated resource defining protein families and complexes as they are commonly encountered in biomedical text. In FamPlex the gene-level constituents of families and complexes are defined in a flexible format allowing for multi-level, hierarchical membership. To create FamPlex, text strings corresponding to entities were identified empirically from literature and linked manually to uniform identifiers; these identifiers were also mapped to equivalent entries in multiple related databases. FamPlex also includes curated prefix and suffix patterns that improve named entity recognition and event extraction. Evaluation of REACH extractions on a test corpus of ∼54,000 articles showed that FamPlex significantly increased grounding accuracy for families and complexes (from 15 to 71%). The hierarchical organization of entities in FamPlex also made it possible to integrate otherwise unconnected mechanistic information across families, subfamilies, and individual proteins. Applications of FamPlex to the TRIPS/DRUM reading system and the Biocreative VI Bioentity Normalization Task dataset demonstrated the utility of FamPlex in other settings. FamPlex is an effective resource for improving named entity recognition, grounding, and relationship resolution in automated reading of biomedical text. The content in FamPlex is available in both tabular and Open Biomedical Ontology formats at https://github.com/sorgerlab/famplex under the Creative Commons CC0 license and has been integrated into the TRIPS/DRUM and REACH reading systems.

  11. The Role of Habitability Studies in Space Facility and Vehicle Design

    NASA Technical Reports Server (NTRS)

    Adams, Constance M.

    1999-01-01

    This document is a viewgraph presentation which reviews the role of the space architect in designing a space vehicle with habitability as a chief concern. Habitability is composed of the qualities of the environment or system which support the crew in working and living. All the impacts from habitability are interdependent; i.e., impacts to well-being can impact performance, safety or efficiency. After reviewing the issues relating to habitability the presentation discusses the application of these issues in two case studies. The first studies the Bio-Plex Hab chamber which includes designs of the living and working areas. The second case study is the ISS-TransHab which is being studied as a prototype for Mars transit.

  12. Winnowing and Flocculation in Bio-physical Cohesive Substrate: A Flume Experimental and Estuarine Study

    NASA Astrophysics Data System (ADS)

    Ye, L.; Parsons, D. R.; Manning, A. J.

    2016-12-01

    Cohesive sediment, or mud, is ubiquitously found in most aqueous environments, such as coasts and estuaries. The study of cohesive sediment behaviors requires the synchronous description of mutual interactions of grains (e.g., winnowing and flocculation), their physical properties (e.g., grain size) and also the ambient water. Herein, a series of flume experiments (14 runs) with different substrate mixtures of sand-clay-EPS (Extracellular Polymeric Substrates: secreted by aquatic microorganisms) are combined with an estuarine field survey (Dee estuary, NW England) to investigate the behavior of suspensions over bio-physical cohesive substrates. The experimental results indicate that winnowing and flocculation occur pervasively in bio-physical cohesive flow systems. Importantly however, the evolution of the bed and bedform dynamics and hence turbulence production can be lower when cohesivity is high. The estuarine survey also revealed that the bio-physical cohesion provided by both the clay and microorganism fractions in the bed, that pervasively exists in many natural estuarine systems, plays a significant role in controlling the interactions between bed substrate and sediment suspension and deposition, including controlling processes such as sediment winnowing, flocculation and re-deposition. Full understanding of these processes are essential in advancing sediment transport modelling and prediction studies across natural estuarine systems and the work will report on an improved conceptual model for sediment sorting deposition in bio-physical cohesive substrates.

  13. Evaluation of the Impact of Excipients and an Albendazole Salt on Albendazole Concentrations in Upper Small Intestine Using an In Vitro Biorelevant Gastrointestinal Transfer (BioGIT) System.

    PubMed

    Kourentas, Alexandros; Vertzoni, Maria; Khadra, Ibrahim; Symillides, Mira; Clark, Hugh; Halbert, Gavin; Butler, James; Reppas, Christos

    2016-09-01

    An in vitro biorelevant gastrointestinal transfer (BioGIT) system was assessed for its ability to mimic recently reported albendazole concentrations in human upper small intestine after administration of free base suspensions to fasted adults in absence and in presence of supersaturation promoting excipients (hydroxypropylmethylcellulose and lipid self-emulsifying vehicles). The in vitro method was also used to evaluate the likely impact of using the sulfate salt on albendazole concentrations in upper small intestine. In addition, BioGIT data were compared with equilibrium solubility data of the salt and the free base in human aspirates and biorelevant media. The BioGIT system adequately simulated the average albendazole gastrointestinal transfer process and concentrations in upper small intestine after administration of the free base suspensions to fasted adults. However, the degree of supersaturation observed in the duodenal compartment was greater than in vivo. Albendazole sulfate resulted in minimal increase of albendazole concentrations in the duodenal compartment of the BioGIT, despite improved equilibrium solubility observed in human aspirates and biorelevant media, indicating that the use of a salt is unlikely to lead to any significant oral absorption advantage for albendazole. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  14. Chromium (VI) reduction in acetate- and molasses-amended natural media: empirical model development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Scott; Boukhalfa, Hakim; Karra, Satish

    Stimulating indigenous microbes to reduce heavy metals from highly toxic oxidized species to more benign reduced species is a promising groundwater remediation technique that has already seen successful field applications. Designing such a bio-remediation scheme requires a model incorporating the kinetics of nonlinear bio-geochemical interactions between multiple species. With this motivation, we performed a set of microcosm experiments in natural sediments and their indigenous pore water and microbes, generating simultaneous time series for concentrations of Cr(VI), an electron donor (both molasses and acetate were considered), and biomass. Molasses was found to undergo a rapid direct abiotic reaction which eliminated allmore » Cr(VI) before any biomass had time to grow. This was not found in the acetate microcosms, and a distinct zero-order bio-reduction process was observed. Existing models were found inappropriate and a new set of three coupled governing equations representing these process dynamics were developed and their parameters calibrated against the time series from the acetate-amended microcosms. Cell suspension batch experiments were also performed to calibrate bio-reduction rates in the absence of electron donor and sediment. The donor used to initially grow the cells (molasses or acetate) was found not to impact the reduction rate constants in suspension, which were orders of magnitude larger than those explaining the natural media microcosm experiments. This suggests the limited utility of kinetics determined in suspension for remedial design. Scoping studies on the natural media microcosms were also performed, suggesting limited impact of foreign abiotic material and minimal effect of diffusion limitation in the vertical dimension. These analyses may be of independent value to future researchers.« less

  15. Selective Individual Primary Cell Capture Using Locally Bio-Functionalized Micropores

    PubMed Central

    Liu, Jie; Bombera, Radoslaw; Leroy, Loïc; Roupioz, Yoann; Baganizi, Dieudonné R.; Marche, Patrice N.; Haguet, Vincent; Mailley, Pascal; Livache, Thierry

    2013-01-01

    Background Solid-state micropores have been widely employed for 6 decades to recognize and size flowing unlabeled cells. However, the resistive-pulse technique presents limitations when the cells to be differentiated have overlapping dimension ranges such as B and T lymphocytes. An alternative approach would be to specifically capture cells by solid-state micropores. Here, the inner wall of 15-µm pores made in 10 µm-thick silicon membranes was covered with antibodies specific to cell surface proteins of B or T lymphocytes. The selective trapping of individual unlabeled cells in a bio-functionalized micropore makes them recognizable just using optical microscopy. Methodology/Principal Findings We locally deposited oligodeoxynucleotide (ODN) and ODN-conjugated antibody probes on the inner wall of the micropores by forming thin films of polypyrrole-ODN copolymers using contactless electro-functionalization. The trapping capabilities of the bio-functionalized micropores were validated using optical microscopy and the resistive-pulse technique by selectively capturing polystyrene microbeads coated with complementary ODN. B or T lymphocytes from a mouse splenocyte suspension were specifically immobilized on micropore walls functionalized with complementary ODN-conjugated antibodies targeting cell surface proteins. Conclusions/Significance The results showed that locally bio-functionalized micropores can isolate target cells from a suspension during their translocation throughout the pore, including among cells of similar dimensions in complex mixtures. PMID:23469221

  16. Transition to organized behavior on suspensions of concentrated bacteria

    NASA Astrophysics Data System (ADS)

    Ganguly, Sujoy; Cisneros, Luis; Kessler, John; Goldstein, Raymond

    2008-11-01

    Concentrated populations of the swimming bacterium Bacillus subtilis develop a collective phase, the Zooming BioNematic, that exhibits large-scale coherence analogous to the molecular alignment of nematic liquid crystals. Bacterial suspensions were prepared in order to experimentally measure the transition to organized behavior as a function of the cell number concentration. PIV analysis was used to obtain cell velocities and define an order parameter in order to characterize the dynamics of the system.

  17. Performance Assessment of the CapitalBio Mycobacterium Identification Array System for Identification of Mycobacteria

    PubMed Central

    Liu, Jingbo; Yan, Zihe; Han, Min; Han, Zhijun; Jin, Lingjie; Zhao, Yanlin

    2012-01-01

    The CapitalBio Mycobacterium identification microarray system is a rapid system for the detection of Mycobacterium tuberculosis. The performance of this system was assessed with 24 reference strains, 486 Mycobacterium tuberculosis clinical isolates, and 40 clinical samples and then compared to the “gold standard” of DNA sequencing. The CapitalBio Mycobacterium identification microarray system showed highly concordant identification results of 100% and 98.4% for Mycobacterium tuberculosis complex (MTC) and nontuberculous mycobacteria (NTM), respectively. The sensitivity and specificity of the CapitalBio Mycobacterium identification array for identification of Mycobacterium tuberculosis isolates were 99.6% and 100%, respectively, for direct detection and identification of clinical samples, and the overall sensitivity was 52.5%. It was 100% for sputum, 16.7% for pleural fluid, and 10% for bronchoalveolar lavage fluid, respectively. The total assay was completed in 6 h, including DNA extraction, PCR, and hybridization. The results of this study confirm the utility of this system for the rapid identification of mycobacteria and suggest that the CapitalBio Mycobacterium identification array is a molecular diagnostic technique with high sensitivity and specificity that has the capacity to quickly identify most mycobacteria. PMID:22090408

  18. The minimal cost of life in space.

    PubMed

    Drysdale, A E; Rutkze, C J; Albright, L D; LaDue, R L

    2004-01-01

    The cost of keeping people alive in space is assessed from a theoretical viewpoint and using two actual designs for plant growth systems. While life support is theoretically not very demanding, our ability to implement life support is well below theoretical limits. A theoretical limit has been calculated from requirements and the state of the art for plant growth has been calculated using data from the BIO-Plex PDR and from the Cornell CEA prototype system. The very low efficiency of our current approaches results in a high mission impact, though we can still see how to get a significant reduction in cost of food when compared to supplying it from Earth. Seeing the distribution of costs should allow us to improve our current designs. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

  19. The minimal cost of life in space

    NASA Technical Reports Server (NTRS)

    Drysdale, A. E.; Rutkze, C. J.; Albright, L. D.; LaDue, R. L.

    2004-01-01

    The cost of keeping people alive in space is assessed from a theoretical viewpoint and using two actual designs for plant growth systems. While life support is theoretically not very demanding, our ability to implement life support is well below theoretical limits. A theoretical limit has been calculated from requirements and the state of the art for plant growth has been calculated using data from the BIO-Plex PDR and from the Cornell CEA prototype system. The very low efficiency of our current approaches results in a high mission impact, though we can still see how to get a significant reduction in cost of food when compared to supplying it from Earth. Seeing the distribution of costs should allow us to improve our current designs. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

  20. Dual-force aggregation of magnetic particles enhances label-free quantification of DNA at the sub-single cell level.

    PubMed

    Nelson, Daniel A; Strachan, Briony C; Sloane, Hillary S; Li, Jingyi; Landers, James P

    2014-03-28

    We recently reported the 'pinwheel effect' as the foundation for a DNA assay based on a DNA concentration-dependent aggregation of silica-coated magnetic beads in a rotating magnetic field (RMF). Using a rotating magnet that generated a 5 cm magnetic field that impinged on a circular array of 5mm microwells, aggregation was found to only be effective in a single well at the center of the field. As a result, when multiple samples needed to be analyzed, the single-plex (single well) analysis was tedious, time-consuming and labor-intensive, as each well needed to be exposed to the center of the RMF in a serial manner for consistent well-to-well aggregation. For more effective multiplexing (simultaneous aggregation in 12 wells), we used a circular array of microwells and incorporated 'agitation' as a second force that worked in concert with the RMF to provide effective multiplexed aggregation-based DNA quantitation. The dual-force aggregation (DFA) approach allows for effective simultaneous aggregation in multiple wells (12 demonstrated) of the multi-well microdevice, allowing for 12 samples to be interrogated for DNA content in 140 s, providing a ∼35-fold improvement in time compared to single-plex approach (80 min) and ∼4-fold improvement over conventional fluorospectrometric methods. Furthermore, the increased interaction between DNA and beads provided by DFA improved the limit of detection to 250 fg μL(-1). The correlation between the DFA results and those from a fluorospectrometer, demonstrate DFA as an inexpensive and rapid alternative to more conventional methods (fluorescent and spectrophotometric). Copyright © 2014 Elsevier B.V. All rights reserved.

  1. (Bio)Sensing Using Nanoparticle Arrays: On the Effect of Analyte Transport on Sensitivity.

    PubMed

    Lynn, N Scott; Homola, Jiří

    2016-12-20

    There has recently been an extensive amount of work regarding the development of optical, electrical, and mechanical (bio)sensors employing planar arrays of surface-bound nanoparticles. The sensor output for these systems is dependent on the rate at which analyte is transported to, and interacts with, each nanoparticle in the array. There has so far been little discussion on the relationship between the design parameters of an array and the interplay of convection, diffusion, and reaction. Moreover, current methods providing such information require extensive computational simulation. Here we demonstrate that the rate of analyte transport to a nanoparticle array can be quantified analytically. We show that such rates are bound by both the rate to a single NP and that to a planar surface (having equivalent size as the array), with the specific rate determined by the fill fraction: the ratio between the total surface area used for biomolecular capture with respect to the entire sensing area. We characterize analyte transport to arrays with respect to changes in numerous parameters relevant to experiment, including variation of the nanoparticle shape and size, packing density, flow conditions, and analyte diffusivity. We also explore how analyte capture is dependent on the kinetic parameters related to an affinity-based biosensor, and furthermore, we classify the conditions under which the array might be diffusion- or reaction-limited. The results obtained herein are applicable toward the design and optimization of all (bio)sensors based on nanoparticle arrays.

  2. Developmental validation of the HIrisPlex system: DNA-based eye and hair colour prediction for forensic and anthropological usage.

    PubMed

    Walsh, Susan; Chaitanya, Lakshmi; Clarisse, Lindy; Wirken, Laura; Draus-Barini, Jolanta; Kovatsi, Leda; Maeda, Hitoshi; Ishikawa, Takaki; Sijen, Titia; de Knijff, Peter; Branicki, Wojciech; Liu, Fan; Kayser, Manfred

    2014-03-01

    Forensic DNA Phenotyping or 'DNA intelligence' tools are expected to aid police investigations and find unknown individuals by providing information on externally visible characteristics of unknown suspects, perpetrators and missing persons from biological samples. This is especially useful in cases where conventional DNA profiling or other means remain non-informative. Recently, we introduced the HIrisPlex system, capable of predicting both eye and hair colour from DNA. In the present developmental validation study, we demonstrate that the HIrisPlex assay performs in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines providing an essential prerequisite for future HIrisPlex applications to forensic casework. The HIrisPlex assay produces complete profiles down to only 63 pg of DNA. Species testing revealed human specificity for a complete HIrisPlex profile, while only non-human primates showed the closest full profile at 20 out of the 24 DNA markers, in all animals tested. Rigorous testing of simulated forensic casework samples such as blood, semen, saliva stains, hairs with roots as well as extremely low quantity touch (trace) DNA samples, produced complete profiles in 88% of cases. Concordance testing performed between five independent forensic laboratories displayed consistent reproducible results on varying types of DNA samples. Due to its design, the assay caters for degraded samples, underlined here by results from artificially degraded DNA and from simulated casework samples of degraded DNA. This aspect was also demonstrated previously on DNA samples from human remains up to several hundreds of years old. With this paper, we also introduce enhanced eye and hair colour prediction models based on enlarged underlying databases of HIrisPlex genotypes and eye/hair colour phenotypes (eye colour: N = 9188 and hair colour: N = 1601). Furthermore, we present an online web-based system for individual eye and hair colour prediction from full and partial HIrisPlex DNA profiles. By demonstrating that the HIrisPlex assay is fully compatible with the SWGDAM guidelines, we provide the first forensically validated DNA test system for parallel eye and hair colour prediction now available to forensic laboratories for immediate casework application, including missing person cases. Given the robustness and sensitivity described here and in previous work, the HIrisPlex system is also suitable for analysing old and ancient DNA in anthropological and evolutionary studies. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Direct electronic communication at bio-interfaces assisted by layered-metal-hydroxide slab arrays with controlled nano-micro structures.

    PubMed

    An, Zhe; He, Jing

    2011-10-28

    The electronic transfer (eT) at bio-interfaces has been achieved by orientating 2D inorganic slabs in a regular arrangement with the slab ab-planes vertical to the electrode substrate. The eT rate is effectively promoted by tuning the nano-micro scale structures of perpendicular LDH arrays. This journal is © The Royal Society of Chemistry 2011

  4. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring

    PubMed Central

    Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun

    2016-01-01

    A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring. PMID:27322278

  5. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring.

    PubMed

    Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun

    2016-06-17

    A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring.

  6. A first-passage scheme for determination of overall rate constants for non-diffusion-limited suspensions

    NASA Astrophysics Data System (ADS)

    Lu, Shih-Yuan; Yen, Yi-Ming

    2002-02-01

    A first-passage scheme is devised to determine the overall rate constant of suspensions under the non-diffusion-limited condition. The original first-passage scheme developed for diffusion-limited processes is modified to account for the finite incorporation rate at the inclusion surface by using a concept of the nonzero survival probability of the diffusing entity at entity-inclusion encounters. This nonzero survival probability is obtained from solving a relevant boundary value problem. The new first-passage scheme is validated by an excellent agreement between overall rate constant results from the present development and from an accurate boundary collocation calculation for the three common spherical arrays [J. Chem. Phys. 109, 4985 (1998)], namely simple cubic, body-centered cubic, and face-centered cubic arrays, for a wide range of P and f. Here, P is a dimensionless quantity characterizing the relative rate of diffusion versus surface incorporation, and f is the volume fraction of the inclusion. The scheme is further applied to random spherical suspensions and to investigate the effect of inclusion coagulation on overall rate constants. It is found that randomness in inclusion arrangement tends to lower the overall rate constant for f up to the near close-packing value of the regular arrays because of the inclusion screening effect. This screening effect turns stronger for regular arrays when f is near and above the close-packing value of the regular arrays, and consequently the overall rate constant of the random array exceeds that of the regular array. Inclusion coagulation too induces the inclusion screening effect, and leads to lower overall rate constants.

  7. Improved eye- and skin-color prediction based on 8 SNPs.

    PubMed

    Hart, Katie L; Kimura, Shey L; Mushailov, Vladimir; Budimlija, Zoran M; Prinz, Mechthild; Wurmbach, Elisa

    2013-06-01

    To improve the 7-plex system to predict eye and skin color by increasing precision and detailed phenotypic descriptions. Analysis of an eighth single nucleotide polymorphism (SNP), rs12896399 (SLC24A4), showed a statistically significant association with human eye color (P=0.007) but a rather poor strength of agreement (κ=0.063). This SNP was added to the 7-plex system (rs12913832 at HERC2, rs1545397 at OCA2, rs16891982 at SLC45A2, rs1426654 at SLC24A5, rs885479 at MC1R, rs6119471 at ASIP, and rs12203592 at IRF4). Further, the instruction guidelines on the interpretation of genotypes were changed to create a new 8-plex system. This was based on the analysis of an 803-sample training set of various populations. The newly developed 8-plex system can predict the eye colors brown, green, and blue, and skin colors light, not dark, and not light. It is superior to the 7-plex system with its additional ability to predict blue eye and light skin color. The 8-plex system was tested on an additional 212 samples, the test set. Analysis showed that the number of positive descriptions for eye colors as being brown, green, or blue increased significantly (P=6.98e-15, z-score: -7.786). The error rate for eye-color prediction was low, at approximately 5%, while the skin color prediction showed no error in the test set (1% in training set). We can conclude that the new 8-plex system for the prediction of eye and skin color substantially enhances its former version.

  8. Human Information Processing in the Dynamic Environment (HIPDE)

    DTIC Science & Technology

    2008-01-01

    Albery, 1990) and image mental rotation/orientation (Nethus, et al., 1993). However, because SD typically occurs at low G levels, there is little...cuity C om plex D ecision M aking A ccuracy C om plex D ecision M aking R T C om plex D ecision M aking E fficiency Tracking S low M...cerebral tissue frequently continues to persist even at relatively low Gz levels (including accelerations as low as 3 Gz) during long, multiple peak

  9. Clinical accuracy of a PLEX-ID flu device for simultaneous detection and identification of influenza viruses A and B.

    PubMed

    Tang, Yi-Wei; Lowery, Kristin S; Valsamakis, Alexandra; Schaefer, Virginia C; Chappell, James D; White-Abell, Jill; Quinn, Criziel D; Li, Haijing; Washington, Cicely A; Cromwell, Jenna; Giamanco, Chantel M; Forman, Michael; Holden, Jeffery; Rothman, Richard E; Parker, Michelle L; Ortenberg, Elaine V; Zhang, Lei; Lin, Yea-Lin; Gaydos, Charlotte A

    2013-01-01

    Respiratory tract infections caused by influenza A and B viruses often present nonspecifically, and a rapid, high-throughput laboratory technique that can identify influenza viruses is clinically and epidemiologically desirable. The PLEX-ID Flu assay (Abbott Molecular Inc., Des Plaines, IL) incorporates multilocus PCR and electrospray ionization-mass spectrometry to detect and differentiate influenza A 2009 H1N1 (H1N1-p), seasonal H1N1 (H1N1-s), influenza A H3N2, and influenza B viruses in nasopharyngeal swab (NPS) specimens. The clinical performance characteristics of the PLEX-ID Flu assay in symptomatic patients were determined in this multicenter trial. A total of 2,617 prospectively and retrospectively collected NPS specimens from patients with influenza-like illness between February 2008 and 28 May 2010 were eligible for inclusion in the study. Each specimen was tested in parallel by the PLEX-ID Flu assay and by the Prodesse ProFLU+ assay (Prodesse Inc., Madison, WI), to detect influenza A and B viruses. Specimens testing positive for influenza A virus by ProFLU+ were subtyped as H1N1-p, H1N1-s, or H3N2 by using the ProFAST+ assay (Gen-Probe Prodesse Inc.). The reproducibility of the PLEX-ID Flu assay ranged from 98.3 to 100.0%, as determined by testing a nine-specimen panel at three clinical sites on each of 5 days. Positive percent agreements (PPAs) and negative percent agreements (NPAs) of the PLEX-ID Flu assay were 94.5% and 99.0% for influenza A virus and 96.0% and 99.9% for influenza B virus, respectively. For the influenza A virus subtyping characterization, the PLEX-ID Flu assay had PPAs and NPAs of 98.3% and 97.5% for H1N1-p, 88.6% and 100.0% for H1N1-s, and 98.0% and 99.9% for H3N2, respectively. The overall agreements between the PLEX-ID and Prodesse ProFLU+/ProFAST+ assays were 97.1 to 100.0%. Bidirectional Sanger sequencing analysis revealed that 87.5% of 96 discrepant results between the PLEX-ID Flu and ProFLU+/ProFAST+ assays were found upon influenza A virus detection and H1N1-p subtyping. The PLEX-ID Flu assay demonstrated a high level of accuracy for the simultaneous detection and identification of influenza A and B viruses in patient specimens, providing a new laboratory tool for the rapid diagnosis and management of influenza A and B virus infections.

  10. Versatile bio-ink for covalent immobilization of chimeric avidin on sol-gel substrates.

    PubMed

    Heikkinen, Jarkko J; Kivimäki, Liisa; Määttä, Juha A E; Mäkelä, Inka; Hakalahti, Leena; Takkinen, Kristiina; Kulomaa, Markku S; Hytönen, Vesa P; Hormi, Osmo E O

    2011-10-15

    A bio-ink for covalent deposition of thermostable, high affinity biotin-binding chimeric avidin onto sol-gel substrates was developed. The bio-ink was prepared from heterobifunctional crosslinker 6-maleimidohexanoic acid N-hydroxysuccinimide which was first reacted either with 3-aminopropyltriethoxysilane or 3-aminopropyldimethylethoxysilane to form silane linkers 6-maleimide-N-(3-(triethoxysilyl)propyl)hexanamide or -(ethoxydimethylsilyl)propyl)-hexanamide. C-terminal cysteine genetically engineered to chimeric avidin was reacted with the maleimide group of silane linker in methanol/PBS solution to form a suspension, which was printed on sol-gel modified PMMA film. Different concentrations of chimeric avidin and ratios between silane linkers were tested to find the best properties for the bio-ink to enable gravure or inkjet printing. Bio-ink prepared from 3-aminopropyltriethoxysilane was found to provide the highest amount of active immobilized chimeric avidin. The developed bio-ink was shown to be valuable for automated fabrication of avidin-functionalized polymer films. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. The BioDyn facility on ISS: Advancing biomaterial production in microgravity for commercial applications

    NASA Astrophysics Data System (ADS)

    Myers, Niki; Wessling, Francis; Deuser, Mark; Anderson, C. D.; Lewis, Marian

    1999-01-01

    The primary goals of the BioDyn program are to foster use of the microgravity environment for commercial production of bio-materials from cells, and to develop services and processes for obtaining these materials through space processing. The scope of products includes commercial bio-molecules such as cytokines, other cell growth regulatory proteins, hormones, monoclonal antibodies and enzymes; transplantable cells or tissues which can be improved by low-G processes, or which cannot be obtained through standard processes in earth gravity; agriculture biotechnology products from plant cells; microencapsulation for diabetes treatment; and factors regulating cellular aging. To facilitate BioDyn's commercial science driven goals, hardware designed for ISS incorporates the flexibility for interchange between the different ISS facilities including the glovebox, various thermal units and centrifuges. By providing a permanent research facility, ISS is the critical space-based platform required by scientists for carrying out the long-term experiments necessary for developing bio-molecules and tissues using several cell culture modalities including suspension and anchorage-dependent cell types.

  12. [Development of a universal primers PCR-coupled liquid bead array to detect biothreat bacteria].

    PubMed

    Wen, Hai-yan; Wang, Jing; Liu, Heng-chuan; Sun, Xiao-hong; Yang, Yu; Hu, Kong-xin; Shan, Lin-jun

    2009-10-01

    To develop a fast, high-throughput screening method with suspension array technique for simultaneous detection of biothreat bacteria. 16 S rDNA universal primers for Bacillus anthracis, Francisella tularensis, Yersinia pestis, Brucella spp.and Burkholderia pseudomallei were selected to amplify corresponding regions and the genus-specific or species-specific probes were designed. After amplification of chromosomal DNA by 16 S rDNA primers 341A and 519B, the PCR products were detected by suspension array technique. The sensitivity, specificity, reproducibility and detection power were also analyzed. After PCR amplification by 16 S rDNA primers and specific probe hybridization, the target microorganisms could be identified at genus level, cross reaction was recognized in the same genus. The detection sensitivity of the assay was 1.5 pg/microl (Burkholderia pseudomallei), 20 pg/microl (Brucella spp.), 7 pg/microl (Bacillus anthracis), 0.1 pg/microl (Francisella tularensis), and 1.1 pg/microl (Yersinia pestis), respectively. The coefficient of variation for 15 test of different probes was ranged from 5.18% to 17.88%, it showed good reproducibility. The assay could correctly identify Bacillus anthracis and Yersinia pestis strains in simulated white powder samples. The suspension array technique could be served as an opening screening method for biothreat bacteria rapid detection.

  13. Simplified Analytical Model of a Six-Degree-of-Freedom Large-Gap Magnetic Suspension System

    NASA Technical Reports Server (NTRS)

    Groom, Nelson J.

    1997-01-01

    A simplified analytical model of a six-degree-of-freedom large-gap magnetic suspension system is presented. The suspended element is a cylindrical permanent magnet that is magnetized in a direction which is perpendicular to its axis of symmetry. The actuators are air core electromagnets mounted in a planar array. The analytical model consists of an open-loop representation of the magnetic suspension system with electromagnet currents as inputs.

  14. Bringing colour back after 70 years: Predicting eye and hair colour from skeletal remains of World War II victims using the HIrisPlex system.

    PubMed

    Chaitanya, Lakshmi; Pajnič, Irena Zupanič; Walsh, Susan; Balažic, Jože; Zupanc, Tomaž; Kayser, Manfred

    2017-01-01

    Retrieving information about externally visible characteristics from DNA can provide investigative leads to find unknown perpetrators, and can also help in disaster victim and other missing person identification cases. Aiming for the application to both types of forensic casework, we previously developed and forensically validated the HIrisPlex test system enabling parallel DNA prediction of eye and hair colour. Although a recent proof-of-principle study demonstrated the general suitability of the HIrisPlex system for successfully analysing DNA from bones and teeth of various storage times and conditions, practical case applications to human remains are scarce. In this study, we applied the HIrisPlex system to 49 DNA samples obtained from bones or teeth of World War II victims excavated at six sites, mostly mass graves, in Slovenia. PCR-based DNA quantification ranged from 4pg/μl to 313pg/μl and on an average was 41pg/μl across all samples. All 49 samples generated complete HIrisPlex profiles with the exception of one MC1R DNA marker (N29insA) missing in 83.7% of the samples. In 44 of the 49 samples (89.8%) complete 15-loci autosomal STR (plus amelogenin) profiles were obtained. Of 5 pairs of skeletal remains for which STR profiling suggested an origin in the same individuals, respectively, 4 showed the same HIrisPlex profiles and predicted eye and hair colours, respectively, while discrepancies in one pair (sample 26 and 43) are likely to be explained by DNA quantity and quality issues observed in sample 43. Sample 43 had the lowest DNA concentration of only 4pg/μl, producing least reliable STR results and could be misleading in concluding that samples 43 and 26 originate from the same individual. The HIrisPlex-predicted eye and hair colours from two skeletal samples, suggested to derive from two brothers via STR profiling together with a living sister, were confirmed by the living sister's report. Overall, we demonstrate that after more than 70 years, HIrisPlex-based eye and hair colour prediction from skeletal remains is feasible with high success rate. Our results further encourage the use of the HIrisPlex system in missing person/disaster victim identification to aid the identification process in cases where ante-mortem samples or putative relatives are not directly available, and DNA predicted eye and hair colour information provides leads for locating them, allowing STRbased individual identification. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. C-MEMS for bio-sensing applications

    NASA Astrophysics Data System (ADS)

    Song, Yin; Agrawal, Richa; Wang, Chunlei

    2015-05-01

    Developing highly sensitive, selective, and reproducible miniaturized bio-sensing platforms require reliable biointerface which should be compatible with microfabrication techniques. In this study, we have fabricated pyrolyzed carbon arrays with high surface area as a bio-sensing electrode, and developed the surface functionalization methods to increase biomolecules immobilization efficiency and further understand electrochemical phenomena at biointerfaces. The carbon microelectrode arrays with high aspect ratio have been fabricated by carbon microelectromechanical systems (C-MEMS) and nanomaterials such as graphene have been integrated to further increase surface area. To achieve the efficient covalent immobilization of biomolecules, various oxidation and reduction functionalization methods have been investigated. The oxidation treatment in this study includes vacuum ultraviolet, electrochemical activation, UV/Ozone and oxygen RIE. The reduction treatment includes direct amination and diazonium grafting. The developed bio-sensing platform was then applied for several applications, such as: DNA sensor; H2O2 sensor; aptamer sensor and HIV sensor.

  16. Rapid O serogroup identification of the ten most clinically relevant STECs by Luminex microbead-based suspension array

    USDA-ARS?s Scientific Manuscript database

    Identification and serotyping of Shiga toxin-producing Escherichia coli during foodborne outbreaks can aid in matching clinical, food, and environmental isolates when trying to identify the sources of illness and ultimately food contamination. Herein we describe a Luminex microbead-based suspension ...

  17. A continuous high-throughput bioparticle sorter based on 3D traveling-wave dielectrophoresis.

    PubMed

    Cheng, I-Fang; Froude, Victoria E; Zhu, Yingxi; Chang, Hsueh-Chia; Chang, Hsien-Chang

    2009-11-21

    We present a high throughput (maximum flow rate approximately 10 microl/min or linear velocity approximately 3 mm/s) continuous bio-particle sorter based on 3D traveling-wave dielectrophoresis (twDEP) at an optimum AC frequency of 500 kHz. The high throughput sorting is achieved with a sustained twDEP particle force normal to the continuous through-flow, which is applied over the entire chip by a single 3D electrode array. The design allows continuous fractionation of micron-sized particles into different downstream sub-channels based on differences in their twDEP mobility on both sides of the cross-over. Conventional DEP is integrated upstream to focus the particles into a single levitated queue to allow twDEP sorting by mobility difference and to minimize sedimentation and field-induced lysis. The 3D electrode array design minimizes the offsetting effect of nDEP (negative DEP with particle force towards regions with weak fields) on twDEP such that both forces increase monotonically with voltage to further increase the throughput. Effective focusing and separation of red blood cells from debris-filled heterogeneous samples are demonstrated, as well as size-based separation of poly-dispersed liposome suspensions into two distinct bands at 2.3 to 4.6 microm and 1.5 to 2.7 microm, at the highest throughput recorded in hand-held chips of 6 microl/min.

  18. FilmArray® Gastrointestinal (GI) Panel for Viral Acute Gastroenteritis Detection in Pediatric Patients

    PubMed Central

    Kanwar, Neena; Jackson, Jami; Duffy, Susan; Chapin, Kimberle; Cohen, Daniel; Leber, Amy; Daly, Judy a; Pavia, Andrew; Larsen, Chari; Baca, Tanya; Bender, Jeffery; Bard, Jennifer Dien; Festekjian, Ara; Holmberg, Kristen; Bourzac, Kevin; Selvarangan, Rangaraj

    2017-01-01

    Abstract Background Acute viral gastroenteritis is one of the leading causes of diarrheal diseases. The FilmArray GI Panel is a PCR based assay that detects 22 different enteric pathogens including five viruses (Adenovirus F 40/41, Astrovirus, Norovirus GI/GII, Rotavirus A, and Sapovirus (I, II, IV, and V)) in an hour. The epidemiology and management of acute viral gastroenteritis is described. Methods Children with acute gastroenteritis were prospectively enrolled at emergency departments of five geographically different pediatric facilities during 2015–2016. Stool specimens were collected and tested by the FilmArray GI Panel. Results A total of 1157 subjects were enrolled in the study. Stool specimens from 961 subjects were collected. Subjects with viral, bacterial, and parasitic etiology as identified by the FilmArray GI Panel were 429 (44.6%), 392 (40.8%), and 41 (4.3%), respectively. Viral AGE was common in winter months from October through March (274/429; 63.9%); norovirus was the leading viral agent (205/429; 47.8%) and was more commonly detected in winter months (147/205; 71.7%). Other viruses detected include Adenovirus F 40/41, Astrovirus, Rotavirus, and Sapovirus in 94 (9.8%), 49 (5.1%), 28 (2.9%), and 97 (10.1%) specimens, respectively. Co-infections with multiple pathogens was found in 244 (25.4%) of all specimens tested. Only 39/961 subjects received a viral standard of care (SOC) test result. The FilmArray GI panel detected viruses in higher percentage of stool specimens when SOC was not requested 45% (415/922) vs. requested 36% (14/39) [P = 0.32]. Viral infections were the highest among 148 hospitalizations: virus (26.4%), bacteria (22.9%), bacteria and virus (16.9%), and parasite (0.6%) and norovirus was the leading viral etiology associated with hospitalizations (n = 27; 69.2%). AGE due to viral (24.6%) or bacterial (27.6%) causes had similar repeat visits to hospital [P = 0.45]. Conclusion Viruses are leading cause of AGE resulting in ED visits; norovirus is the leading viral agent. Viral AGE leads to significant hospitalizations and repeat hospital visits. Implementation of comprehensive test like the FilmArray GI panel may aid in appropriate management of children with AGE. Disclosures S. Duffy, BioFire Diagnostics: Investigator, Research grant; K. Chapin, BioFire Diagnostics: Investigator, Research grant; A. Leber, BioFIre Diagnostics: Research Contractor and Scientific Advisor, Research support, Speaker honorarium and Travel expenses; A. Pavia, BioFire Diagnostics: Grant Investigator, Research grant; J. Dien Bard, BioFire: Consultant and Investigator, Research grant and Speaker honorarium; 
 K. Holmberg, BioFire Diagnostics: Employee, Salary; K. Bourzac, BioFire Diagnostics: Employee, Salary; R. Selvarangan, BioFire Diagnostics: Board Member and Investigator, Consulting fee and Research grant; Luminex Diagnostics: Investigator, Research grant

  19. High aspect reactor vessel and method of use

    NASA Technical Reports Server (NTRS)

    Wolf, David A. (Inventor); Sams, Clarence F. (Inventor); Schwarz, Ray P. (Inventor)

    1992-01-01

    An improved bio-reactor vessel and system useful for carrying out mammalian cell growth in suspension in a culture media are presented. The main goal of the invention is to grow and maintain cells under a homogeneous distribution under acceptable biochemical environment of gas partial pressures and nutrient levels without introducing direct agitation mechanisms or associated disruptive mechanical forces. The culture chamber rotates to maintain an even distribution of cells in suspension and minimizes the length of a gas diffusion path. The culture chamber design is presented and discussed.

  20. Suppression of Psyllium Husk Suspension Viscosity by Addition of Water Soluble Polysaccharides.

    PubMed

    Kale, Madhuvanti S; Yadav, Madhav P; Hanah, Kyle A

    2016-10-01

    Psyllium seed husk is an insoluble dietary fiber with many health benefits. It can absorb many times its weight in water, forming very viscous suspensions, which have low palatability and consumer acceptance. We report here a novel approach for decreasing its viscosity, involving inclusion of a soluble polysaccharide in the suspension. This leads to a drastic decrease (up to 87%) in viscosity of suspensions, while maintaining the same dosage level of psyllium and also delivering a significant amount of soluble dietary fiber such as corn bio-fiber gum in a single serving. Four soluble polysaccharides with a range of molecular weights and solution viscosities have been studied for their viscosity suppression effect. Besides improving palatability, another advantage of this approach is that it makes it possible to deliver 2 different dietary fibers in significant quantities, thus offering even greater health benefits. © 2016 Institute of Food Technologists®.

  1. Post-injection hybridization of complementary DNA strands on capillary electrophoresis platforms: a novel solution for dsDNA artifacts.

    PubMed

    McLaren, Robert S; Ensenberger, Martin G; Budowle, Bruce; Rabbach, Dawn; Fulmer, Patricia M; Sprecher, Cindy J; Bessetti, Joseph; Sundquist, Terri M; Storts, Douglas R

    2008-09-01

    Several laboratories have reported the occurrence of a split or n-1 peak at the vWA locus in PowerPlex 16 and PowerPlex ES amplification products separated on 4- and 16-capillary electrophoresis instruments. The root cause of this artifact is post-PCR reannealing of the unlabeled, unincorporated vWA primer to the 3'-end of the tetramethylrhodamine (TMR)-labeled strand of the vWA amplicon. This reannealing occurs in the capillary post-electrokinetic injection. The split peak is eliminated by incorporation into the loading cocktail of a sacrificial hybridization sequence (SHS) oligonucleotide that is complementary to the vWA primer. The SHS preferentially anneals to the primer instead of the TMR-labeled strand of the vWA amplicon. In addition, the n-10/n-18 artifact that may be seen at the vWA locus was determined to be due to double-stranded amplicon formed post-electrokinetic injection into the capillary. This was also eliminated by adding in two Complementary Oligo Targets (COT1 and COT2) in addition to the SHS oligonucleotide into the loading cocktail. These three oligonucleotides are complementary to the 33 bases at the 5'-end of the unlabeled vWA amplicon strand and the 60 bases at its 3'-end and therefore compete for hybridization to the TMR-labeled amplicon strand. Incorporation of these three oligonucleotides in the Internal Lane Standard 600 (ILS600) eliminate both the split peak and n-10/n-18 artifact in PowerPlex 16 and PowerPlex ES amplification products without affecting sizing of alleles at the vWA locus or any locus in the PowerPlex 16, PowerPlex Y, PowerPlex ES, AmpFlSTR Profiler Plus ID, AmpFlSTR Cofiler, and AmpFlSTR SGM Plus kits.

  2. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains

    PubMed Central

    2013-01-01

    Background DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person’s externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Methods Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Results Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Conclusions Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of eye and hair colour of deceased individuals. PMID:23317428

  3. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains.

    PubMed

    Draus-Barini, Jolanta; Walsh, Susan; Pośpiech, Ewelina; Kupiec, Tomasz; Głąb, Henryk; Branicki, Wojciech; Kayser, Manfred

    2013-01-14

    DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person's externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of eye and hair colour of deceased individuals.

  4. S100a8/a9 released by CD11b+Gr1+ neutrophils activates cardiac fibroblasts to initiate angiotensin II-Induced cardiac inflammation and injury.

    PubMed

    Wu, Yina; Li, Yulin; Zhang, Congcong; A, Xi; Wang, Yueli; Cui, Wei; Li, Huihua; Du, Jie

    2014-06-01

    Angiotensin II induces cardiovascular injury, in part, by activating inflammatory response; however, the initial factors that trigger the inflammatory cascade remain unclear. Microarray analysis of cardiac tissue exposed to systemic angiotensin II infusion revealed that extracellular heterodimeric proteins S100a8/a9 were highly upregulated. The increase in S100a8/a9 mRNA of CD11b(+)Gr1(+) neutrophils isolated from both the peripheral blood and heart was highest on day 1 of angiotensin II infusion and decreased to baseline at day 7. Immunostaining showed that S100a8/a9 was primarily present in infiltrating CD11b(+)Gr1(+) neutrophils in the heart. The receptor for advanced glycation end products, an S100a8/a9 receptor, was expressed in cardiac fibroblasts (CFs). Microarray analysis and Bio-Plex protein array showed that treatment of CFs with recombinant S100a8/a9 activated multiple chemokine and cytokines released. Luciferase reporter assay indicated S100a8/a9-activated nuclear factor-κ B pathway in CFs. Consequently, recombinant S100a8/a9-treated CFs promoted migration of monocytes and CFs, whereas neutralizing S100a9 antibody blocked S100a9 or receptor for advanced glycation end products-suppressed cellular migration. Finally, administration of a neutralizing S100a9 antibody prevented angiotensin II infusion-induced nuclear factor-κ B activation, inflammatory cell infiltration, cytokine production, subsequent perivascular and interstitial fibrosis, and hypertrophy in heart. Our findings identify neutrophil-produced S100a8/a9 as an initial proinflammatory factor needed to trigger inflammation and cardiac injury during acute hypertension.

  5. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording.

    PubMed

    Ren, Lei; Xu, Shujia; Gao, Jie; Lin, Zi; Chen, Zhipeng; Liu, Bin; Liang, Liang; Jiang, Lelun

    2018-04-13

    Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode-skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

  6. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording

    PubMed Central

    Ren, Lei; Xu, Shujia; Gao, Jie; Lin, Zi; Chen, Zhipeng; Liu, Bin; Liang, Liang; Jiang, Lelun

    2018-01-01

    Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode–skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring. PMID:29652835

  7. [Establishment and verification of detecting multiple biomarkers for ovarian cancer by suspension array technology].

    PubMed

    Zhao, B B; Yang, Z J; Wang, Q; Pan, Z M; Zhang, W; Li, D R; Li, L

    2016-10-25

    Objective: Establish and validation of combined detecting of CCL18, CXCL1, C1D, TM4SF1, FXR1, TIZ suspension array technology. Methods: (1)CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ protein were coupled with polyethylene microspheres. Biotinylated CCL18, CXCL1 polyclonal antibody and sheep anti-human IgG polyclonal antibody were prepared simultaneously. The best packaged concentrations of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigens were optimized. The best packaged concentrations of CCL18, CXCL1 polyclonal antibodys and C1D, TM4SF1, FXR1, TIZ sheep anti-human IgG polyclonal antibody were optimized to establish a stable detected suspension array.(2)Sixty patients confirmed by pathological examination with ovarian cancer(ovarian cancer group)which treated in Affiliated Tumor Hospital of Guangxi Medical University, 30 patients with ovarian benign tumor(benign group)and 30 cases of healthy women(control group)were chosen between September 2003 and December 2003. Suspension array technology and ELISA method were used to detect expression of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1 and TIZ IgG autoantibody contented in 3 groups of serum, then to compare the diagnostic efficiency and diagnostic accuracy of two methods(coefficient of variation between batch and batch). Results: (1)This research successfully established stable detecting system of CCL18, CXCL1, C1D, TM4SF1, FXR1 and TIZ IgG autoantibody. The best concentration of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigen package were 8, 8, 12, 8, 4 and 8 μg/ml; the best detection of CCL18, CXCL1 biotin polyclonal antibody and C1D, TM4SF1, FXR1, TIZ sheep anti-huamne IgG polyclonal antibody were respectively 4, 2, 2, 4, 4 and 2 μg/ml.(2)Suspension array technology and ELISA method were used to detect CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody of three groups in serum were similar( P >0.05).(3)The comparison of two methods in the diagnosis of efficiency: the diagnostic accuracy of two methods were 99.2%(119/120)and 94.2%(113/120), the difference was statistically significant( P =0.031). The sensitivity of the diagnosis of ovarian cancer of two methods were 100.0%(60/60)and 93.3%(56/60), specific degrees were 100.0%(59/59)and 93.4%(57/61), positive predictive value was 100.0%(60/60)and 93.3%(56/60), negative predictive value was 98.3%(59/60)and 95.0%(57/60), the difference was statistically significant( P <0.05).(4)The detected results of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody shown that the diagnostic accuracy of suspension array technology was superior to those of ELISA method(all P <0.05). Conclusion: The study has established the stable detection of suspension array technology, and the diagnostic efficiency and diagnostic accuracy was much better than that by ELISA.

  8. Evaluation of a nematode bio-product Dbx-20% against root-knot nematode Meloidogyne incognita affecting grapevine under field conditions.

    PubMed

    Aboul-Eid, H Z; Noweer, E M A; Ashour, N E; Ameen, Hoda H

    2006-01-01

    A field trial was conducted in El-Shourouk Farm, El-Beheira governorate, western Nile valley, Egypt to determine the effectiveness of the commercial bio-product Dbx 1003 20% containing the nematode-trapping fungus Dactylaria brochopaga against root-knot nematode Meloidogyne incognita infesting grapevine variety Superior. Its effects on plant growth criteria and yield production were also investigated. The fungus was introduced to soil by either of two ways. First: soil was drenched with spore suspension at the rate of 3 l/tree. Second: 1/2 kg of a vermiculite substrate, as a carrier of spores and mycelia was added around each tree both as single and twice application in autumn and spring. All treatments significantly reduced M. incognita J2 in soil and number of root galls compared with the untreated control. Significant yield increases have been observed with all treatments compared with the untreated control. Spores suspension twice applications gave the highest yield production.

  9. Developmental validation of the PowerPlex(®) ESI 16 and PowerPlex(®) ESI 17 Systems: STR multiplexes for the new European standard.

    PubMed

    Tucker, Valerie C; Hopwood, Andrew J; Sprecher, Cynthia J; McLaren, Robert S; Rabbach, Dawn R; Ensenberger, Martin G; Thompson, Jonelle M; Storts, Douglas R

    2011-11-01

    In response to the ENFSI and EDNAP groups' call for new STR multiplexes for Europe, Promega(®) developed a suite of four new DNA profiling kits. This paper describes the developmental validation study performed on the PowerPlex(®) ESI 16 (European Standard Investigator 16) and the PowerPlex(®) ESI 17 Systems. The PowerPlex(®) ESI 16 System combines the 11 loci compatible with the UK National DNA Database(®), contained within the AmpFlSTR(®) SGM Plus(®) PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to reduce the amplicon size of the loci found in the AmpFlSTR(®) SGM Plus(®) kit. This design facilitates increased robustness and amplification success for the loci used in the national DNA databases created in many countries, when analyzing degraded DNA samples. The PowerPlex(®) ESI 17 System amplifies the same loci as the PowerPlex(®) ESI 16 System, but with the addition of a primer pair for the SE33 locus. Tests were designed to address the developmental validation guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM), and those of the DNA Advisory Board (DAB). Samples processed include DNA mixtures, PCR reactions spiked with inhibitors, a sensitivity series, and 306 United Kingdom donor samples to determine concordance with data generated with the AmpFlSTR(®) SGM Plus(®) kit. Allele frequencies from 242 white Caucasian samples collected in the United Kingdom are also presented. The PowerPlex(®) ESI 16 and ESI 17 Systems are robust and sensitive tools, suitable for the analysis of forensic DNA samples. Full profiles were routinely observed with 62.5pg of a fully heterozygous single source DNA template. This high level of sensitivity was found to impact on mixture analyses, where 54-86% of unique minor contributor alleles were routinely observed in a 1:19 mixture ratio. Improved sensitivity combined with the robustness afforded by smaller amplicons has substantially improved the quantity of data obtained from degraded samples, and the improved chemistry confers exceptional tolerance to high levels of laboratory prepared inhibitors. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Comparison of 3 kidney injury multiplex panels in rats.

    PubMed

    John-Baptiste, Annette; Vitsky, Allison; Sace, Frederick; Zong, Qing; Ko, Mira; Yafawi, Rolla; Liu, Ling

    2012-01-01

    Kidney injury biomarkers have been utilized by pharmaceutical companies as a means to assess the potential of candidate drugs to induce nephrotoxicity. Multiple platforms and assay methods exist, but the comparison of these methods has not been described. Millipore's Kidney Toxicity panel, EMD/Novagen's Widescreen Kidney Toxicity panel, and Meso Scales Kidney Injury panel were selected based on published information. Kidney injury molecule 1, cystatin C, clusterin, and osteopontin were the 4 biomarkers common among all kits tested and the focus of this study. Rats were treated with a low and high dose of para-aminophenol, a known nephrotoxicant, and urine samples were collected and analyzed on the Bio-Plex 200 or MSD's Sector Imager 6000, according to manufacturers specifications. Comparatively, of the 3 kits, Millipore was the most consistent in detecting elevations of 3 out of the 4 biomarkers at both dose levels and indicated time points.

  11. Multidimensional Normalization to Minimize Plate Effects of Suspension Bead Array Data.

    PubMed

    Hong, Mun-Gwan; Lee, Woojoo; Nilsson, Peter; Pawitan, Yudi; Schwenk, Jochen M

    2016-10-07

    Enhanced by the growing number of biobanks, biomarker studies can now be performed with reasonable statistical power by using large sets of samples. Antibody-based proteomics by means of suspension bead arrays offers one attractive approach to analyze serum, plasma, or CSF samples for such studies in microtiter plates. To expand measurements beyond single batches, with either 96 or 384 samples per plate, suitable normalization methods are required to minimize the variation between plates. Here we propose two normalization approaches utilizing MA coordinates. The multidimensional MA (multi-MA) and MA-loess both consider all samples of a microtiter plate per suspension bead array assay and thus do not require any external reference samples. We demonstrate the performance of the two MA normalization methods with data obtained from the analysis of 384 samples including both serum and plasma. Samples were randomized across 96-well sample plates, processed, and analyzed in assay plates, respectively. Using principal component analysis (PCA), we could show that plate-wise clusters found in the first two components were eliminated by multi-MA normalization as compared with other normalization methods. Furthermore, we studied the correlation profiles between random pairs of antibodies and found that both MA normalization methods substantially reduced the inflated correlation introduced by plate effects. Normalization approaches using multi-MA and MA-loess minimized batch effects arising from the analysis of several assay plates with antibody suspension bead arrays. In a simulated biomarker study, multi-MA restored associations lost due to plate effects. Our normalization approaches, which are available as R package MDimNormn, could also be useful in studies using other types of high-throughput assay data.

  12. Fine-mapping identifies multiple prostate cancer risk loci at 5p15, one of which associates with TERT expression

    PubMed Central

    Kote-Jarai, Zsofia; Saunders, Edward J.; Leongamornlert, Daniel A.; Tymrakiewicz, Malgorzata; Dadaev, Tokhir; Jugurnauth-Little, Sarah; Ross-Adams, Helen; Al Olama, Ali Amin; Benlloch, Sara; Halim, Silvia; Russel, Roslin; Dunning, Alison M.; Luccarini, Craig; Dennis, Joe; Neal, David E.; Hamdy, Freddie C.; Donovan, Jenny L.; Muir, Ken; Giles, Graham G.; Severi, Gianluca; Wiklund, Fredrik; Gronberg, Henrik; Haiman, Christopher A.; Schumacher, Fredrick; Henderson, Brian E.; Le Marchand, Loic; Lindstrom, Sara; Kraft, Peter; Hunter, David J.; Gapstur, Susan; Chanock, Stephen; Berndt, Sonja I.; Albanes, Demetrius; Andriole, Gerald; Schleutker, Johanna; Weischer, Maren; Canzian, Federico; Riboli, Elio; Key, Tim J.; Travis, Ruth C.; Campa, Daniele; Ingles, Sue A.; John, Esther M.; Hayes, Richard B.; Pharoah, Paul; Khaw, Kay-Tee; Stanford, Janet L.; Ostrander, Elaine A.; Signorello, Lisa B.; Thibodeau, Stephen N.; Schaid, Dan; Maier, Christiane; Vogel, Walther; Kibel, Adam S.; Cybulski, Cezary; Lubinski, Jan; Cannon-Albright, Lisa; Brenner, Hermann; Park, Jong Y.; Kaneva, Radka; Batra, Jyotsna; Spurdle, Amanda; Clements, Judith A.; Teixeira, Manuel R.; Govindasami, Koveela; Guy, Michelle; Wilkinson, Rosemary A.; Sawyer, Emma J.; Morgan, Angela; Dicks, Ed; Baynes, Caroline; Conroy, Don; Bojesen, Stig E.; Kaaks, Rudolf; Vincent, Daniel; Bacot, François; Tessier, Daniel C.; Easton, Douglas F.; Eeles, Rosalind A.

    2013-01-01

    Associations between single nucleotide polymorphisms (SNPs) at 5p15 and multiple cancer types have been reported. We have previously shown evidence for a strong association between prostate cancer (PrCa) risk and rs2242652 at 5p15, intronic in the telomerase reverse transcriptase (TERT) gene that encodes TERT. To comprehensively evaluate the association between genetic variation across this region and PrCa, we performed a fine-mapping analysis by genotyping 134 SNPs using a custom Illumina iSelect array or Sequenom MassArray iPlex, followed by imputation of 1094 SNPs in 22 301 PrCa cases and 22 320 controls in The PRACTICAL consortium. Multiple stepwise logistic regression analysis identified four signals in the promoter or intronic regions of TERT that independently associated with PrCa risk. Gene expression analysis of normal prostate tissue showed evidence that SNPs within one of these regions also associated with TERT expression, providing a potential mechanism for predisposition to disease. PMID:23535824

  13. Shape-coded silica nanotubes for multiplexed bioassay: rapid and reliable magnetic decoding protocols

    PubMed Central

    He, Bo; Kim, Sung Kyoung; Son, Sang Jun; Lee, Sang Bok

    2010-01-01

    Aims The recent development of 1D barcode arrays has proved their capabilities to be applicable to highly multiplexed bioassays. This article introduces two magnetic decoding protocols for suspension arrays of shape-coded silica nanotubes to process multiplexed assays rapidly and easily, which will benefit the minimization and automation of the arrays. Methods In the first protocol, the magnetic nanocrystals are incorporated into the inner voids of barcoded silica nanotubes in order to give the nanotubes magnetic properties. The second protocol is performed by trapping the barcoded silica nanotubes onto streptavidin-modified magnetic beads. Results The rapid and easy decoding process was demonstrated by applying the above two protocols to multiplexed assays, resulting in high selectivity. Furthermore, the magnetic bead-trapped barcode nanotubes provided a great opportunity to exclude the use of dye molecules in multiplexed assays by using barcode nanotubes as signals. Conclusion The rapid and easy manipulation of encoded carriers using magnetic properties could be used to develop promising suspension arrays for portable bioassays. PMID:20025466

  14. Clinical evaluation of the BioFire FilmArray® BioThreat-E test for the diagnosis of Ebola Virus Disease in Guinea.

    PubMed

    Gay-Andrieu, Françoise; Magassouba, N'Fally; Picot, Valentina; Phillips, Cynthia L; Peyrefitte, Christophe N; Dacosta, Brigitte; Doré, Ahmadou; Kourouma, Fode; Ligeon-Ligeonnet, Véronique; Gauby, Corentin; Longuet, Christophe; Scullion, Matt; Faye, Ousmane; Machuron, Jean Louis; Miller, Mark

    2017-07-01

    The recent West Africa Ebola outbreak highlighted the need to provide access to rapid, safe and reliable Ebola Virus Disease diagnostics. The objective of this field study was to assess the clinical performance of the FilmArray ® BioThreat-E test for the detection of Ebola Zaïre virus in whole blood in symptomatic patients suspected of Ebola Virus Disease in Conakry (Guinea) from March to July 2015. The BioThreat-E test was compared to the two RT-PCRs, using serum, implemented at Donka Hospital in the emergency context: an in-house developed quantitative one-step RT-PCR adapted from the Weidmann technique, and the RealStar ® Filovirus RT-PCR Kit 1.0 (Altona-Diagnostics). We also assessed the performance of this assay in noninvasive specimens (urine and saliva) to detect infected patients. Of 135 patients enrolled and eligible for performance assessment on whole blood, the sensitivity was 95.7% [95% CI: 85.5-99.5] and specificity 100% [95% CI: 95.9-100]. Of the 37 symptomatic infected patients able to provide saliva and/or urine samples, 34 of the 35 saliva samples and all 3 of the urine samples were positive with the BioThreat-E test. This study showed that the FilmArray BioThreat-E test performs comparably to conventional molecular tests under field conditions, providing results and interpretation in approximately 1h. Due to its operational characteristics, it can be easily deployed in the field during an epidemic and could also be a useful tool for post-outbreak surveillance. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Open-loop characteristics of magnetic suspension systems using electromagnets mounted in a planar array

    NASA Technical Reports Server (NTRS)

    Groom, Nelson J.; Britcher, Colin P.

    1992-01-01

    The open-loop characteristics of a Large-Gap Magnetic Suspension System (LGMSS) were studied and numerical results are presented. The LGMSS considered provides five-degree-of-freedom control. The suspended element is a cylinder that contains a core composed of permanent magnet material. The magnetic actuators are air core electromagnets mounted in a planar array. Configurations utilizing five, six, seven, and eight electromagnets were investigated and all configurations were found to be controllable from coil currents and observable from suspended element positions. Results indicate that increasing the number of coils has an insignificant effect on mode shapes and frequencies.

  16. A photonic crystal hydrogel suspension array for the capture of blood cells from whole blood

    NASA Astrophysics Data System (ADS)

    Zhang, Bin; Cai, Yunlang; Shang, Luoran; Wang, Huan; Cheng, Yao; Rong, Fei; Gu, Zhongze; Zhao, Yuanjin

    2016-02-01

    Diagnosing hematological disorders based on the separation and detection of cells in the patient's blood is a significant challenge. We have developed a novel barcode particle-based suspension array that can simultaneously capture and detect multiple types of blood cells. The barcode particles are polyacrylamide (PAAm) hydrogel inverse opal microcarriers with characteristic reflection peak codes that remain stable during cell capture on their surfaces. The hydrophilic PAAm hydrogel scaffolds of the barcode particles can entrap various plasma proteins to capture different cells in the blood, with little damage to captured cells.Diagnosing hematological disorders based on the separation and detection of cells in the patient's blood is a significant challenge. We have developed a novel barcode particle-based suspension array that can simultaneously capture and detect multiple types of blood cells. The barcode particles are polyacrylamide (PAAm) hydrogel inverse opal microcarriers with characteristic reflection peak codes that remain stable during cell capture on their surfaces. The hydrophilic PAAm hydrogel scaffolds of the barcode particles can entrap various plasma proteins to capture different cells in the blood, with little damage to captured cells. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06368j

  17. Stability considerations for magnetic suspension systems using electromagnets mounted in a planar array

    NASA Technical Reports Server (NTRS)

    Groom, Nelson J.; Britcher, Colin P.

    1991-01-01

    Mathematical models of a 5, 6, 7, and 8 coil large gap magnetic suspension system (MSDS) are presented. Some of the topics covered include: force and torque equations, reduction of state-space form, natural modes, origins of modes, effect of rotation in azimuth (yaw), future work, and n-coil ring conclusions.

  18. Performance characteristics of bio-inspired metal nanostructures as surface-enhanced Raman scattered (SERS) substrates

    DOE PAGES

    Areizaga-Martinez, Hector I.; Kravchenko, Ivan; Lavrik, Nickolay V.; ...

    2016-08-26

    The fabrication of high-performance plasmonic nanomaterials for bio-sensing and trace chemical detection is a field of intense theoretical and experimental research. The use of metal-silicon nanopillar arrays as analytical sensors has been reported with reasonable results in recent years. The use of bio-inspired nanocomposite structures that follow the Fibonacci numerical architecture offers the opportunity to develop nanostructures with theoretically higher and more reproducible plasmonic fields over extended areas. The work presented here describes the nanofabrication process for a series of 40 µm × 40 µm bio-inspired arrays classified as asymmetric fractals (sunflower seeds and romanesco broccoli), bilaterally symmetric (acacia leavesmore » and honeycombs), and radially symmetric (such as orchids and lily flowers) using electron beam lithography. In addition, analytical capabilities were evaluated using surface-enhanced Raman scattering (SERS). Here, the substrate characterization and SERS performance of the developed substrates as the strategies to assess the design performance are presented and discussed.« less

  19. Performance characteristics of bio-inspired metal nanostructures as surface-enhanced Raman scattered (SERS) substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Areizaga-Martinez, Hector I.; Kravchenko, Ivan; Lavrik, Nickolay V.

    The fabrication of high-performance plasmonic nanomaterials for bio-sensing and trace chemical detection is a field of intense theoretical and experimental research. The use of metal-silicon nanopillar arrays as analytical sensors has been reported with reasonable results in recent years. The use of bio-inspired nanocomposite structures that follow the Fibonacci numerical architecture offers the opportunity to develop nanostructures with theoretically higher and more reproducible plasmonic fields over extended areas. The work presented here describes the nanofabrication process for a series of 40 µm × 40 µm bio-inspired arrays classified as asymmetric fractals (sunflower seeds and romanesco broccoli), bilaterally symmetric (acacia leavesmore » and honeycombs), and radially symmetric (such as orchids and lily flowers) using electron beam lithography. In addition, analytical capabilities were evaluated using surface-enhanced Raman scattering (SERS). Here, the substrate characterization and SERS performance of the developed substrates as the strategies to assess the design performance are presented and discussed.« less

  20. Performance Characteristics of Bio-Inspired Metal Nanostructures as Surface-Enhanced Raman Scattered (SERS) Substrates.

    PubMed

    Areizaga-Martinez, Hector I; Kravchenko, Ivan; Lavrik, Nickolay V; Sepaniak, Michael J; Hernández-Rivera, Samuel P; De Jesús, Marco A

    2016-09-01

    The fabrication of high-performance plasmonic nanomaterials for bio-sensing and trace chemical detection is a field of intense theoretical and experimental research. The use of metal-silicon nanopillar arrays as analytical sensors has been reported with reasonable results in recent years. The use of bio-inspired nanocomposite structures that follow the Fibonacci numerical architecture offers the opportunity to develop nanostructures with theoretically higher and more reproducible plasmonic fields over extended areas. The work presented here describes the nanofabrication process for a series of 40 µm × 40 µm bio-inspired arrays classified as asymmetric fractals (sunflower seeds and romanesco broccoli), bilaterally symmetric (acacia leaves and honeycombs), and radially symmetric (such as orchids and lily flowers) using electron beam lithography. In addition, analytical capabilities were evaluated using surface-enhanced Raman scattering (SERS). The substrate characterization and SERS performance of the developed substrates as the strategies to assess the design performance are presented and discussed. © The Author(s) 2016.

  1. EPA Recommends Modifications to Part of Industri-plex Superfund Cleanup in Woburn, Mass.

    EPA Pesticide Factsheets

    The U.S. Environmental Protection Agency (EPA) proposes recommended modifications to part of the cleanup of the Industri-plex Superfund Site in Woburn, Mass. Beginning today (May 3, 2018), there will be a 14-day public comment period on EPA’s proposal.

  2. Non-homogeneous flow profiles in sheared bacterial suspensions

    NASA Astrophysics Data System (ADS)

    Samanta, Devranjan; Cheng, Xiang

    Bacterial suspensions under shear exhibit interesting rheological behaviors including the remarkable ``superfluidic'' state with vanishing viscosity at low shear rates. Theoretical studies have shown that such ``superfluidic'' state is linked with non-homogeneous shear flows, which are induced by coupling between nematic order of active fluids and hydrodynamics of shear flows. However, although bulk rheology of bacterial suspensions has been experimentally studied, shear profiles within bacterial suspensions have not been explored so far. Here, we experimentally investigate the flow behaviors of E. coli suspensions under planar oscillatory shear. Using confocal microscopy and PIV, we measure velocity profiles across gap between two shear plates. We find that with increasing shear rates, high-concentration bacterial suspensions exhibit an array of non-homogeneous flow behaviors like yield-stress flows and shear banding. We show that these non-homogeneous flows are due to collective motion of bacterial suspensions. The phase diagram of sheared bacterial suspensions is systematically mapped as functions of shear rates an bacterial concentrations. Our experiments provide new insights into rheology of bacterial suspensions and shed light on shear induced dynamics of active fluids. Chemical Engineering and Material Science department.

  3. Halbach arrays in precision motion control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trumper, D.L.; Williams, M.E.

    1995-02-01

    The Halbach array was developed for use as an optical element in particle accelerators. Following up on a suggestion from Klaus Halbach, the authors have investigated the utility of such arrays as the permanent magnet structure for synchronous machines in cartesian, polar, and cylindrical geometries. Their work has focused on the design of a novel Halbach array linear motor for use in a magnetic suspension stage for photolithography. This paper presents the details of the motor design and its force and power characteristics.

  4. Understanding Single-Stranded Telomere End Binding by an Essential Protein

    DTIC Science & Technology

    2000-08-01

    BioPharma Inc., 1885 33rd Street, Boulder, CO 80301 Traditional sequential medicinal chemistry methods have been augmented by combinatorial synthesis...on the same wells that were being analyzed in parallel by RP-HPLC/UV for purity. The sampling protocol for purity determination at Array BioPharma is

  5. Exploring target-specific primer extension in combination with a bead-based suspension array for multiplexed detection and typing using Streptococcus suis as a model pathogen

    PubMed Central

    van der Wal, Fimme J.; Achterberg, René P.; van Solt-Smits, Conny; Bergervoet, Jan H. W.; de Weerdt, Marjanne; Wisselink, Henk J.

    2017-01-01

    We investigated the feasibility of an assay based on target-specific primer extension, combined with a suspension array, for the multiplexed detection and typing of a veterinary pathogen in animal samples, using Streptococcus suis as a model pathogen. A procedure was established for simultaneous detection of 6 S. suis targets in pig tonsil samples (i.e., 4 genes associated with serotype 1, 2, 7, or 9, the generic S. suis glutamate dehydrogenase gene [gdh], and the gene encoding the extracellular protein factor [epf]). The procedure was set up as a combination of protocols: DNA isolation from porcine tonsils, a multiplex PCR, a multiplex target-specific primer extension, and finally a suspension array as the readout. The resulting assay was compared with a panel of conventional PCR assays. The proposed multiplex assay can correctly identify the serotype of isolates and is capable of simultaneous detection of multiple targets in porcine tonsillar samples. The assay is not as sensitive as the current conventional PCR assays, but with the correct sampling strategy, the assay can be useful for screening pig herds to establish which S. suis serotypes are circulating in a pig population. PMID:28980519

  6. Genetic diversity of K-antigen gene clusters of Escherichia coli and their molecular typing using a suspension array.

    PubMed

    Yang, Shuang; Xi, Daoyi; Jing, Fuyi; Kong, Deju; Wu, Junli; Feng, Lu; Cao, Boyang; Wang, Lei

    2018-04-01

    Capsular polysaccharides (CPSs), or K-antigens, are the major surface antigens of Escherichia coli. More than 80 serologically unique K-antigens are classified into 4 groups (Groups 1-4) of capsules. Groups 1 and 4 contain the Wzy-dependent polymerization pathway and the gene clusters are in the order galF to gnd; Groups 2 and 3 contain the ABC-transporter-dependent pathway and the gene clusters consist of 3 regions, regions 1, 2 and 3. Little is known about the variations among the gene clusters. In this study, 9 serotypes of K-antigen gene clusters (K2ab, K11, K20, K24, K38, K84, K92, K96, and K102) were sequenced and correlated with their CPS chemical structures. On the basis of sequence data, a K-antigen-specific suspension array that detects 10 distinct CPSs, including the above 9 CPSs plus K30, was developed. This is the first report to catalog the genetic features of E. coli K-antigen variations and to develop a suspension array for their molecular typing. The method has a number of advantages over traditional bacteriophage and serum agglutination methods and lays the foundation for straightforward identification and detection of additional K-antigens in the future.

  7. Using arm and hand gestures to command robots during stealth operations

    NASA Astrophysics Data System (ADS)

    Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi

    2012-06-01

    Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-offreedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

  8. Using Arm and Hand Gestures to Command Robots during Stealth Operations

    NASA Technical Reports Server (NTRS)

    Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi

    2012-01-01

    Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

  9. Ferritin-Templated Quantum-Dots for Quantum Logic Gates

    NASA Technical Reports Server (NTRS)

    Choi, Sang H.; Kim, Jae-Woo; Chu, Sang-Hyon; Park, Yeonjoon; King, Glen C.; Lillehei, Peter T.; Kim, Seon-Jeong; Elliott, James R.

    2005-01-01

    Quantum logic gates (QLGs) or other logic systems are based on quantum-dots (QD) with a stringent requirement of size uniformity. The QD are widely known building units for QLGs. The size control of QD is a critical issue in quantum-dot fabrication. The work presented here offers a new method to develop quantum-dots using a bio-template, called ferritin, that ensures QD production in uniform size of nano-scale proportion. The bio-template for uniform yield of QD is based on a ferritin protein that allows reconstitution of core material through the reduction and chelation processes. One of the biggest challenges for developing QLG is the requirement of ordered and uniform size of QD for arrays on a substrate with nanometer precision. The QD development by bio-template includes the electrochemical/chemical reconsitution of ferritins with different core materials, such as iron, cobalt, manganese, platinum, and nickel. The other bio-template method used in our laboratory is dendrimers, precisely defined chemical structures. With ferritin-templated QD, we fabricated the heptagonshaped patterned array via direct nano manipulation of the ferritin molecules with a tip of atomic force microscope (AFM). We also designed various nanofabrication methods of QD arrays using a wide range manipulation techniques. The precise control of the ferritin-templated QD for a patterned arrangement are offered by various methods, such as a site-specific immobilization of thiolated ferritins through local oxidation using the AFM tip, ferritin arrays induced by gold nanoparticle manipulation, thiolated ferritin positioning by shaving method, etc. In the signal measurements, the current-voltage curve is obtained by measuring the current through the ferritin, between the tip and the substrate for potential sweeping or at constant potential. The measured resistance near zero bias was 1.8 teraohm for single holoferritin and 5.7 teraohm for single apoferritin, respectively.

  10. Typeability of PowerPlex Y (Promega) profiles in selected tissue samples incubated in various environments.

    PubMed

    Niemcunowicz-Janica, Anna; Pepiński, Witold; Janica, Jacek Robert; Janica, Jerzy; Skawrońska, Małgorzata; Koc-Zórawska, Ewa

    2007-01-01

    In cases of decomposed bodies, Y chromosomal STR markers may be useful in identification of a male relative. The authors assessed typeability of PowerPlex Y (Promega) loci in post mortem tissue material stored in various environments. Kidney, spleen and pancreas specimens were collected during autopsies of five persons aged 20-30 years, whose time of death was determined within the limit of 14 hours. Tissue material was incubated at 21 degrees C and 4 degrees C in various environmental conditions. DNA was extracted by the organic method from tissue samples collected in 7-day intervals and subsequently typed using the PowerPlexY-STR kit and ABI 310. A fast decrease in the typeability rate was seen in specimens incubated in peat soil and in sand. Kidney tissue samples were typeable in all PowerPlexY-STR loci within 63 days of incubation at 4 degrees C. Faster DNA degradation was recorded in spleen and pancreas specimens. In samples with negative genotyping results, no DNA was found by fluorometric quantitation. Decomposed soft tissues are a potential material for DNA typing.

  11. Developmental validation of the PowerPlex(®) Fusion 6C System.

    PubMed

    Ensenberger, Martin G; Lenz, Kristy A; Matthies, Learden K; Hadinoto, Gregory M; Schienman, John E; Przech, Angela J; Morganti, Michael W; Renstrom, Daniel T; Baker, Victoria M; Gawrys, Kori M; Hoogendoorn, Marlijn; Steffen, Carolyn R; Martín, Pablo; Alonso, Antonio; Olson, Hope R; Sprecher, Cynthia J; Storts, Douglas R

    2016-03-01

    The PowerPlex(®) Fusion 6C System is a 27-locus, six-dye, multiplex that includes all markers in the expanded CODIS core loci and increases overlap with STR database standards throughout the world. Additionally, it contains two, rapidly mutating, Y-STRs and is capable of both casework and database workflows, including direct amplification. A multi-laboratory developmental validation study was performed on the PowerPlex(®) Fusion 6C System. Here, we report the results of that study which followed SWGDAM guidelines and includes data for: species specificity, sensitivity, stability, precision, reproducibility and repeatability, case-type samples, concordance, stutter, DNA mixtures, and PCR-based procedures. Where appropriate we report data from both extracted DNA samples and direct amplification samples from various substrates and collection devices. Samples from all studies were separated on both Applied Biosystems 3500 series and 6-dye capable 3130 series Genetic Analyzers and data is reported for each. Together, the data validate the design and demonstrate the performance of the PowerPlex(®) Fusion 6C System. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  12. Effects of microbial DNA on human DNA profiles generated using the PowerPlex® 16 HS system.

    PubMed

    Dembinski, Gina M; Picard, Christine J

    2017-11-01

    Most crime scenes are not sterile and therefore may be contaminated with environmental DNA, especially if a decomposing body is found. Collecting biological evidence from this individual will yield DNA samples mixed with microbial DNA. This also becomes important if postmortem swabs are collected from sexually assaulted victims. Although genotyping kits undergo validation tests, including bacterial screens, they do not account for the diverse microbial load during decomposition. We investigated the effect of spiking human DNA samples with known concentrations of DNA from 17 microbe species associated with decomposition on DNA profiles produced using the Promega PowerPlex ® HS system. Two species, Bacillus subtilis and Mycobacterium smegmatis, produced an extraneous allele at the TPOX locus. When repeated with the PowerPlex ® Fusion kit, the extra allele no longer amplified with these two species. This experiment demonstrates that caution should be exhibited if microbial load is high and the PowerPlex ® 16HS system is used. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  13. Two-Dimensional Si-Nanodisk Array Fabricated Using Bio-Nano-Process and Neutral Beam Etching for Realistic Quantum Effect Devices

    NASA Astrophysics Data System (ADS)

    Huang, Chi-Hsien; Igarashi, Makoto; Woné, Michel; Uraoka, Yukiharu; Fuyuki, Takashi; Takeguchi, Masaki; Yamashita, Ichiro; Samukawa, Seiji

    2009-04-01

    A high-density, large-area, and uniform two-dimensional (2D) Si-nanodisk array was successfully fabricated using the bio-nano-process, advanced etching techniques, including a treatment using nitrogen trifluoride and hydrogen radical (NF3 treatment) and a damage-free chlorine neutral beam (NB). By using the surface oxide formed by neutral beam oxidation (NBO) for the preparation of a 2D nanometer-sized iron core array as an etching mask, a well-ordered 2D Si-nanodisk array was obtained owing to the dangling bonds of the surface oxide. By changing the NF3 treatment time without changing the quantum effect of each nanodisk, we could control the gap between adjacent nanodisks. A device with two electrodes was fabricated to investigate the electron transport in a 2D Si-nanodisk array. Current fluctuation and time-dependent currents were clearly observed owing to the charging-discharging of the nanodisks adjacent to the current percolation path. The new structure may have great potential for future novel quantum effect devices.

  14. Concepts and Development of Bio-Inspired Distributed Embedded Wired/Wireless Sensor Array Architectures for Acoustic Wave Sensing in Integrated Aerospace Vehicles

    NASA Technical Reports Server (NTRS)

    Ghoshal, Anindya; Prosser, William H.; Kirikera, Goutham; Schulz, Mark J.; Hughes, Derke J.; Orisamolu, Wally

    2003-01-01

    This paper discusses the modeling of acoustic emissions in plate structures and their sensing by embedded or surface bonded piezoelectric sensor arrays. Three different modeling efforts for acoustic emission (AE) wave generation and propagation are discussed briefly along with their advantages and disadvantages. Continuous sensors placed at right angles on a plate are being discussed as a new approach to measure and locate the source of acoustic waves. Evolutionary novel signal processing algorithms and bio-inspired distributed sensor array systems are used on large structures and integrated aerospace vehicles for AE source localization and preliminary results are presented. These systems allow for a great reduction in the amount of data that needs to be processed and also reduce the chances of false alarms from ambient noises. It is envisioned that these biomimetic sensor arrays and signal processing techniques will be useful for both wireless and wired sensor arrays for real time health monitoring of large integrated aerospace vehicles and earth fixed civil structures. The sensor array architectures can also be used with other types of sensors and for other applications.

  15. Developmental validation of the PowerPlex(®) ESI 16/17 Fast and PowerPlex(®) ESX 16/17 Fast Systems.

    PubMed

    McLaren, Robert S; Bourdeau-Heller, Jeanne; Patel, Jaynish; Thompson, Jonelle M; Pagram, Jenny; Loake, Thomas; Beesley, David; Pirttimaa, Markus; Hill, Carolyn R; Duewer, David L; Kline, Margaret C; Butler, John M; Storts, Douglas R

    2014-11-01

    The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems. This paper describes the developmental validation study performed on these new fast systems following guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM) and those of the DNA Advisory Board (DAB). Validation data demonstrate that these systems are sensitive for detecting low levels of DNA while also being capable of generating robust profiles from the high amount of input DNA present in direct-amplification samples. These systems are also tolerant to both high concentrations of PCR inhibitors as well as to slight variations in the final concentration of master mix and primer pair present in the amplification reaction that might be encountered due to pipetting error. The results of this validation study demonstrate that these systems may be used on multiple thermal cyclers and capillary electrophoresis platforms. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  16. Delivery and Establishing Slow Release Carbon Source to the Hanford Vadose Zone Using Colloidal Silica Suspension Injection and Subsequent Gelation - Laboratory Study

    NASA Astrophysics Data System (ADS)

    Zhong, L.; Lee, M. H.; Lee, B.; Yang, S.

    2016-12-01

    Delivery of nutrient to and establish a slow release carbon source in the vadose zone and capillary fringe zone is essential for setting up of a long-lasting bioremediation of contaminations in those zones. Conventional solution-based injection and infiltration approaches are facing challenges to achieve the delivery and remedial goals. Aqueous silica suspensions undergo a delayed gelation process under favorite geochemical conditions. The delay in gelation provides a time window for the injection of the suspension into the subsurface; and the gelation of the amendment-silica suspension enables the amendment-laden gel to stay in the target zone and slowly release the constituents for contaminant remediation. This approach can potentially be applied to deliver bio-nutrients to the vadose zone and capillary fringe zone for enhanced bioremediation and achieve remedial goals. This research was conducted to demonstrate delayed gelation of colloidal silica suspensions when carbon sources were added and to prove the gelation occurs in sediments under vadose conditions. Sodium lactate, vegetable oil, ethanol, and molasses were tested as the examples of carbon source (or nutrient) amendments. The rheological properties of the silica suspensions during the gelation were characterized. The influence of silica, salinity, nutrient concentrations, and the type of nutrients was studied. The kinetics of nutrient release from silica-nutrient gel was quantified using molasses as the example, and the influence of suspension gelation time was evaluated. The injection behavior of the suspensions was investigated by monitoring their viscosity changes and the injection pressures when the suspensions were delivered into sediment columns.

  17. Selenium Supplementation in Fish: A Combined Chemical and Biomolecular Study to Understand Sel-Plex Assimilation and Impact on Selenoproteome Expression in Rainbow Trout (Oncorhynchus mykiss)

    PubMed Central

    Sweetman, John; Martin, Samuel A. M.; Feldmann, Jörg; Secombes, Christopher J.

    2015-01-01

    Background Selenium (Se) is an essential oligonutrient, as a component of several Se-containing proteins (selenoproteins), which exert important biological functions within an organism. In livestock, Se-enriched products have been proposed as dietary supplements to be included into functional feeds for animal preventive health care. To this end, it is important to understand the optimal range of concentrations for supplementation and how long it takes to be assimilated into the organism. Methods In this study, rainbow trout (Oncorhynchus mykiss) were fed a control diet containing 0.9 g Kg-1 Se or the same diet supplemented with a Se-Yeast product (Sel-Plex) to achieve Se concentrations ranging from 1.5–8.9 g Kg-1 for a period of ten weeks. Fish were sampled every two weeks for analysis. The kinetics of Se bioaccumulation and the effects on fish selenoprotein expression was determined in different tissues combining chemical and bimolecular techniques. Results The Sel-Plex enriched diets did not have any effect on survival and growth performance. The highest Se levels were found in liver and kidney followed by muscle and blood cells. Analysis of the Se concentration factor showed that liver is able to initially regulate the amount of Se accumulated. However, with higher dietary Se level (4.8 and 8.9 g Kg-1) and longer times of exposure (10 weeks), regulation is ineffective and the Se tissue concentration increases. The expression of the selected trout selenoprotein transcripts showed an inverse correlation with Sel-Plex augmentation in most cases. In liver, kidney and blood cells the highest up-regulation of the trout selenoprotein genes was seen mostly in the group fed the diet enriched with the lowest concentration of Sel-Plex (0.5 g Kg-1) for 10 weeks. Conclusion Sel-Plex may represent an excellent Se supplement to deliver a high level of Se without provoking harm to the fish and to guarantee the maximal absorption of the element. According to our results, a dietary supplementation of Sel-Plex between 0.5 and 4 g Kg-1 may allow maximal benefits, whereas 8 g Kg-1 may be excessive for the purpose of supplementation. PMID:25978314

  18. Nanopore arrays in a silicon membrane for parallel single-molecule detection: fabrication

    NASA Astrophysics Data System (ADS)

    Schmidt, Torsten; Zhang, Miao; Sychugov, Ilya; Roxhed, Niclas; Linnros, Jan

    2015-08-01

    Solid state nanopores enable translocation and detection of single bio-molecules such as DNA in buffer solutions. Here, sub-10 nm nanopore arrays in silicon membranes were fabricated by using electron-beam lithography to define etch pits and by using a subsequent electrochemical etching step. This approach effectively decouples positioning of the pores and the control of their size, where the pore size essentially results from the anodizing current and time in the etching cell. Nanopores with diameters as small as 7 nm, fully penetrating 300 nm thick membranes, were obtained. The presented fabrication scheme to form large arrays of nanopores is attractive for parallel bio-molecule sensing and DNA sequencing using optical techniques. In particular the signal-to-noise ratio is improved compared to other alternatives such as nitride membranes suffering from a high-luminescence background.

  19. Nanopore arrays in a silicon membrane for parallel single-molecule detection: fabrication.

    PubMed

    Schmidt, Torsten; Zhang, Miao; Sychugov, Ilya; Roxhed, Niclas; Linnros, Jan

    2015-08-07

    Solid state nanopores enable translocation and detection of single bio-molecules such as DNA in buffer solutions. Here, sub-10 nm nanopore arrays in silicon membranes were fabricated by using electron-beam lithography to define etch pits and by using a subsequent electrochemical etching step. This approach effectively decouples positioning of the pores and the control of their size, where the pore size essentially results from the anodizing current and time in the etching cell. Nanopores with diameters as small as 7 nm, fully penetrating 300 nm thick membranes, were obtained. The presented fabrication scheme to form large arrays of nanopores is attractive for parallel bio-molecule sensing and DNA sequencing using optical techniques. In particular the signal-to-noise ratio is improved compared to other alternatives such as nitride membranes suffering from a high-luminescence background.

  20. Multilayer Ferritin Array for Bionanobattery

    NASA Technical Reports Server (NTRS)

    Chu, Sang-Hyon (Inventor); Choi, Sang H. (Inventor); Kim, Jae-Woo (Inventor); Lillehei, Peter T. (Inventor); Park, Yeonjoon (Inventor); King, Glen C. (Inventor); Elliott, James R., Jr. (Inventor)

    2009-01-01

    A thin-film electrode for a bio-nanobattery is produced by consecutively depositing arrays of a ferritin protein on a substrate, employing a spin self-assembly procedure. By this procedure, a first ferritin layer is first formed on the substrate, followed by building a second, oppositely-charged ferritin layer on the top of the first ferritin layer to form a bilayer structure. Oppositely-charged ferritin layers are subsequently deposited on top of each other until a desired number of bilayer structures is produced. An ordered, uniform, stable and robust, thin-film electrode material of enhanced packing density is presented, which provides optimal charge density for the bio-nanobattery.

  1. Industri-Plex, OU-1, Master Cover Certification Report: Industri-Plex Site: September 30, 2008: Appendix C, C.1-C.2

    EPA Pesticide Factsheets

    2012-04-22

    ... Sincerely, \\ -/) I iJ/;5.~~.k. -r--7~.~~- ... 2.i:

  2. A superconducting large-angle magnetic suspension

    NASA Technical Reports Server (NTRS)

    Downer, James; Goldie, James; Torti, Richard

    1991-01-01

    The component technologies were developed required for an advanced control moment gyro (CMG) type of slewing actuator for large payloads. The key component of the CMG is a large-angle magnetic suspension (LAMS). The LAMS combines the functions of the gimbal structure, torque motors, and rotor bearings of a CMG. The LAMS uses a single superconducting source coil and an array of cryoresistive control coils to produce a specific output torque more than an order of magnitude greater than conventional devices. The designed and tested LAMS system is based around an available superconducting solenoid, an array of twelve room-temperature normal control coils, and a multi-input, multi-output control system. The control laws were demonstrated for stabilizing and controlling the LAMS system.

  3. Algorithm for Surface of Translation Attached Radiators (A-STAR). Volume III. Computer Codes.

    DTIC Science & Technology

    1982-05-01

    SEGMENT ARRAYS* C2075 CCPMCN /83jTI 44DDFNPTNBAND C2080 COM MCN IBDT21 N’,RL.YR(831, yS(83)eYS1(82).XB1(82) C2085 COMMON /GOT?/ 14(82)PSVt .12).CVt82 C2090...i a.4 ZZaZ lti 12 )-ZCI CI 10 RH020 . XNXX +VV*VV*ZZ*ZZ 2’ REaS REINZ 4 A3mA IUC 49CEXPI-U*SK*ER R14.IP I RR 8 CEDGE(SOT j-E(OOE(CA IMPEOANCE ELEMENTS...FvAv.S~%Lt IAXpSIIs PINER) 57*f ?C ********* ************* i5?C COM ~PLEX SIFIPSON INTEGRATION RflUTINE.j7 i N E.x,!& pSvsIPK Il~~i Agj:;)2c.19v20 5ON

  4. Deconstruction of the beaten Path-Sidestep interaction network provides insights into neuromuscular system development

    PubMed Central

    Li, Hanqing; Watson, Ash; Olechwier, Agnieszka; Anaya, Michael; Sorooshyari, Siamak K; Harnett, Dermott P; Lee, Hyung-Kook (Peter); Vielmetter, Jost; Fares, Mario A; Garcia, K Christopher; Özkan, Engin

    2017-01-01

    An ‘interactome’ screen of all Drosophila cell-surface and secreted proteins containing immunoglobulin superfamily (IgSF) domains discovered a network formed by paralogs of Beaten Path (Beat) and Sidestep (Side), a ligand-receptor pair that is central to motor axon guidance. Here we describe a new method for interactome screening, the Bio-Plex Interactome Assay (BPIA), which allows identification of many interactions in a single sample. Using the BPIA, we ‘deorphanized’ four more members of the Beat-Side network. We confirmed interactions using surface plasmon resonance. The expression patterns of beat and side genes suggest that Beats are neuronal receptors for Sides expressed on peripheral tissues. side-VI is expressed in muscle fibers targeted by the ISNb nerve, as well as at growth cone choice points and synaptic targets for the ISN and TN nerves. beat-V genes, encoding Side-VI receptors, are expressed in ISNb and ISN motor neurons. PMID:28829740

  5. Environmental Systems Test Stand

    NASA Astrophysics Data System (ADS)

    Barta, D.; Young, J.; Ewert, M.; Lee, S.; Wells, P.; Fortson, R.; Castillo, J.

    A test stand has been developed for the evaluation of prototype lighting, environmental control and crop cultivation technologies for plant production within an advanced life support system. Design of the test stand was based on preliminary designs of the center growth bay of the Biomass Production Chamber, one of several modules of the Bioregenerative Planetary Life Support Systems Test Complex (BIO- Plex). It consists of two controlled-environment shelves, each with 4.7 m2 of area for crop growth (150 cm width, 315 cm length). There are two chilled water loops, one for operation at conventional temperatures (5-10C) for air temperature and humidity control and one for operation at higher temperatures (15-50C) for waste heat acquisition and heating. Modular light boxes, utilizing either air-cooled or water- jacketed HPS lamps, have been developed. This modular design will allow for easy replacement of new lighting technologies within the light banks. An advanced data acquisition and control system has been developed utilizing localized, networked- based data acquisition modules and programmed with object-based control software.

  6. Food System Trade Study for a Near-Term Mars Mission

    NASA Technical Reports Server (NTRS)

    Levri, Julie; Luna, Bernadette (Technical Monitor)

    2000-01-01

    This paper evaluates several food system options for a near-term Mars mission, based on plans for the 120-day BIO-Plex test. Food systems considered in the study are based on the International Space Station (ISS) Assembly Phase and Assembly Complete food systems. The four systems considered are: 1) ISS assembly phase food system (US portion) with individual packaging without salad production; 2) ISS assembly phase food system (US portion) with individual packaging, with salad production; 3) ISS assembly phase food system (US portion) with bulk packaging, with salad production; 4) ISS assembly complete food system (US portion) with bulk packaging with salad and refrigeration/freezing. The food system options are assessed using equivalent system mass (ESM), which evaluates each option based upon the mass, volume, power, cooling and crewtime requirements that are associated with each food system option. However, since ESM is unable to elucidate the differences in psychological benefits between the food systems, a qualitative evaluation of each option is also presented.

  7. Industrial grade 2D molybdenum disulphide (MoS2): an in vitro exploration of the impact on cellular uptake, cytotoxicity, and inflammation

    NASA Astrophysics Data System (ADS)

    Moore, Caroline; Movia, Dania; Smith, Ronan J.; Hanlon, Damien; Lebre, Filipa; Lavelle, Ed C.; Byrne, Hugh J.; Coleman, Jonathan N.; Volkov, Yuri; McIntyre, Jennifer

    2017-06-01

    The recent surge in graphene research, since its liquid phase monolayer isolation and characterization in 2004, has led to advancements which are accelerating the exploration of alternative 2D materials such as molybdenum disulphide (MoS2), whose unique physico-chemical properties can be exploited in applications ranging from cutting edge electronic devices to nanomedicine. However, to assess any potential impact on human health and the environment, the need to understand the bio-interaction of MoS2 at a cellular and sub-cellular level is critical. Notably, it is important to assess such potential impacts of materials which are produced by large scale production techniques, rather than research grade materials. The aim of this study was to explore cytotoxicity, cellular uptake and inflammatory responses in established cell-lines that mimic different potential exposure routes (inhalation, A549; ingestion, AGS; monocyte, THP-1) following incubation with MoS2 flakes of varying sizes (50 nm, 117 nm and 177 nm), produced by liquid phase exfoliation. Using high content screening (HCS) and Live/Dead assays, it was established that 1 µg ml-1 (for the three different MoS2 sizes) did not induce toxic effects on any of the cell-lines. Confocal microscopy images revealed a normal cellular morphology in all cases. Transmission electron microscopy (TEM) confirmed the uptake of all MoS2 nanomaterials in all the cell-lines, the MoS2 ultimately locating in single membrane vesicles. At such sub-lethal doses, inflammatory responses are observed, however, associated, at least partially, with the presence of lipopolysaccharide endotoxin in nanomaterial suspensions and surfactant samples. Therefore, the inflammatory response of the cells to the MoS2 or endotoxin contamination was interrogated using a 10-plex ELISA which illustrates cytokine production. The experiments carried out using wild-type and endotoxin hyporesponsive bone marrow derived dendritic cells confirmed that the inflammatory responses result from a combination of endotoxin contamination, the MoS2 nanomaterials themselves, and the stabilizing surfactant.

  8. Programmable micrometer-sized motor array based on live cells.

    PubMed

    Xie, Shuangxi; Wang, Xiaodong; Jiao, Niandong; Tung, Steve; Liu, Lianqing

    2017-06-13

    Trapping and transporting microorganisms with intrinsic motility are important tasks for biological, physical, and biomedical applications. However, fast swimming speed makes the manipulation of these organisms an inherently challenging task. In this study, we demonstrated that an optoelectrical technique, namely, optically induced dielectrophoresis (ODEP), could effectively trap and manipulate Chlamydomonas reinhardtii (C. reinhardtii) cells swimming at velocities faster than 100 μm s -1 . Furthermore, live C. reinhardtii cells trapped by ODEP can form a micrometer-sized motor array. The rotating frequency of the cells ranges from 50 to 120 rpm, which can be reversibly adjusted with a fast response speed by varying the optical intensity. Functional flagella have been demonstrated to play a decisive role in the rotation. The programmable cell array with a rotating motion can be used as a bio-micropump to drive the liquid flow in microfludic chips and may shed new light on bio-actuation.

  9. Custom oligonucleotide array-based CGH: a reliable diagnostic tool for detection of exonic copy-number changes in multiple targeted genes

    PubMed Central

    Vasson, Aurélie; Leroux, Céline; Orhant, Lucie; Boimard, Mathieu; Toussaint, Aurélie; Leroy, Chrystel; Commere, Virginie; Ghiotti, Tiffany; Deburgrave, Nathalie; Saillour, Yoann; Atlan, Isabelle; Fouveaut, Corinne; Beldjord, Cherif; Valleix, Sophie; Leturcq, France; Dodé, Catherine; Bienvenu, Thierry; Chelly, Jamel; Cossée, Mireille

    2013-01-01

    The frequency of disease-related large rearrangements (referred to as copy-number mutations, CNMs) varies among genes, and search for these mutations has an important place in diagnostic strategies. In recent years, CGH method using custom-designed high-density oligonucleotide-based arrays allowed the development of a powerful tool for detection of alterations at the level of exons and made it possible to provide flexibility through the possibility of modeling chips. The aim of our study was to test custom-designed oligonucleotide CGH array in a diagnostic laboratory setting that analyses several genes involved in various genetic diseases, and to compare it with conventional strategies. To this end, we designed a 12-plex CGH array (135k; 135 000 probes/subarray) (Roche Nimblegen) with exonic and intronic oligonucleotide probes covering 26 genes routinely analyzed in the laboratory. We tested control samples with known CNMs and patients for whom genetic causes underlying their disorders were unknown. The contribution of this technique is undeniable. Indeed, it appeared reproducible, reliable and sensitive enough to detect heterozygous single-exon deletions or duplications, complex rearrangements and somatic mosaicism. In addition, it improves reliability of CNM detection and allows determination of boundaries precisely enough to direct targeted sequencing of breakpoints. All of these points, associated with the possibility of a simultaneous analysis of several genes and scalability ‘homemade' make it a valuable tool as a new diagnostic approach of CNMs. PMID:23340513

  10. Assessment of the Capability of the NGDS Prototype to Replace the JBAIDS for Environmental Sample Analysis

    DTIC Science & Technology

    2016-11-01

    FilmArray system. 15. SUBJECT TERMS BioFire FilmArray system Dry Filter Unit (DFU) Joint Biological...collectors, such as the Dry Filter Unit (DFU). The FilmArray system showed enormous potential to rapidly screen samples for a wide range of biological...specific focus on the efficient implementation of environmental detectors and collectors, such as Dry Filter Units (DFUs). The JUPITR ATD members

  11. Genetic profile of a multi-ethnic population from Guiné-Bissau (west African coast) using the new PowerPlex 16 System kit.

    PubMed

    Gonçalves, Rita; Jesus, José; Fernandes, Ana Teresa; Brehm, António

    2002-09-10

    Allele and haplotype frequencies of 15 chromosome STR loci included in the kit PowerPlex16 System from Promega, were determined in a sample of unrelated males from Guiné-Bissau, a country from the west African coast. All individuals were subjected to an interview in order to make sure that their ancestors belonged to the same ethnic group. This way we intended to look for possible inter-ethnic differences. PowerPlex 16 includes STRs not studied before in any multi-ethnic population. The kit includes two new allele markers (Penta D and Penta E), which are very useful either in forensics or population genetic studies. The Guinean population presents significant differences when compared with other African populations.

  12. Molecular and immunological tools for the evaluation of the cellular immune response in the neotropical monkey Saimiri sciureus, a non-human primate model for malaria research.

    PubMed

    Riccio, Evelyn K P; Pratt-Riccio, Lilian R; Bianco-Júnior, Cesare; Sanchez, Violette; Totino, Paulo R R; Carvalho, Leonardo J M; Daniel-Ribeiro, Cláudio Tadeu

    2015-04-18

    The neotropical, non-human primates (NHP) of the genus Saimiri and Aotus are recommended by the World Health Organization as experimental models for the study of human malaria because these animals can be infected with the same Plasmodium that cause malaria in humans. However, one limitation is the lack of immunological tools to assess the immune response in these models. The present study focuses on the development and comparative use of molecular and immunological methods to evaluate the cellular immune response in Saimiri sciureus. Blood samples were obtained from nineteen uninfected Saimiri. Peripheral blood mononuclear cells (PBMC) from these animals and splenocytes from one splenectomized animal were cultured for 6, 12, 18, 24, 48, 72 and 96 hrs in the presence of phorbol-12-myristate-13-acetate and ionomycin. The cytokine levels in the supernatant were detected using human and NHP cytometric bead array Th1/Th2 cytokine kits, the Bio-Plex Pro Human Cytokine Th1/Th2 Assay, enzyme-linked immunosorbent assay, enzyme-linked immunospot assays and intracellular cytokine secretion assays. Cytokine gene expression was examined through TaqMan® Gene Expression Real-Time PCR using predesigned human gene-specific primers and probes or primers and probes designed based on published S. sciureus cytokine sequences. The use of five assays based on monoclonal antibodies specific for human cytokines facilitated the detection of IL-2, IL-4 and/or IFN-γ. TaqMan array plates facilitated the detection of 12 of the 28 cytokines assayed. However, only seven cytokines (IL-1A, IL-2, IL-10, IL-12B, IL-17, IFN-β, and TNF) presented relative expression levels of at least 70% of the gene expression observed in human PBMC. The use of primers and probes specific for S. sciureus cytokines facilitated the detection of transcripts that showed relative expression below the threshold of 70%. The most efficient evaluation of cytokine gene expression, in PBMC and splenocytes, was observed after 6-12 hrs of culture, except for LTA in PBMC, whose expression was best analysed after 24 hrs of culture. Real-time PCR facilitates the analysis of a large number of cytokines altered during malaria infection, and this technique is considered the best tool for the evaluation of the cellular immune response in S. sciureus.

  13. Ultra-high-aspect-orthogonal and tunable three dimensional polymeric nanochannel stack array for BioMEMS applications

    NASA Astrophysics Data System (ADS)

    Heo, Joonseong; Kwon, Hyukjin J.; Jeon, Hyungkook; Kim, Bumjoo; Kim, Sung Jae; Lim, Geunbae

    2014-07-01

    Nanofabrication technologies have been a strong advocator for new scientific fundamentals that have never been described by traditional theory, and have played a seed role in ground-breaking nano-engineering applications. In this study, we fabricated ultra-high-aspect (~106 with O(100) nm nanochannel opening and O(100) mm length) orthogonal nanochannel array using only polymeric materials. Vertically aligned nanochannel arrays in parallel can be stacked to form a dense nano-structure. Due to the flexibility and stretchability of the material, one can tune the size and shape of the nanochannel using elongation and even roll the stack array to form a radial-uniformly distributed nanochannel array. The roll can be cut at discretionary lengths for incorporation with a micro/nanofluidic device. As examples, we demonstrated ion concentration polarization with the device for Ohmic-limiting/overlimiting current-voltage characteristics and preconcentrated charged species. The density of the nanochannel array was lower than conventional nanoporous membranes, such as anodic aluminum oxide membranes (AAO). However, accurate controllability over the nanochannel array dimensions enabled multiplexed one microstructure-on-one nanostructure interfacing for valuable biological/biomedical microelectromechanical system (BioMEMS) platforms, such as nano-electroporation.Nanofabrication technologies have been a strong advocator for new scientific fundamentals that have never been described by traditional theory, and have played a seed role in ground-breaking nano-engineering applications. In this study, we fabricated ultra-high-aspect (~106 with O(100) nm nanochannel opening and O(100) mm length) orthogonal nanochannel array using only polymeric materials. Vertically aligned nanochannel arrays in parallel can be stacked to form a dense nano-structure. Due to the flexibility and stretchability of the material, one can tune the size and shape of the nanochannel using elongation and even roll the stack array to form a radial-uniformly distributed nanochannel array. The roll can be cut at discretionary lengths for incorporation with a micro/nanofluidic device. As examples, we demonstrated ion concentration polarization with the device for Ohmic-limiting/overlimiting current-voltage characteristics and preconcentrated charged species. The density of the nanochannel array was lower than conventional nanoporous membranes, such as anodic aluminum oxide membranes (AAO). However, accurate controllability over the nanochannel array dimensions enabled multiplexed one microstructure-on-one nanostructure interfacing for valuable biological/biomedical microelectromechanical system (BioMEMS) platforms, such as nano-electroporation. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr00350k

  14. Optical position measurement for a large gap magnetic suspension system: Design and performance analysis

    NASA Technical Reports Server (NTRS)

    Welch, Sharon S.; Clemmons, James I., Jr.; Shelton, Kevin J.; Duncan, Walter C.

    1994-01-01

    An optical measurement system (OMS) has been designed and tested for a large gap magnetic suspension system (LGMSS). The LGMSS will be used to study control laws for magnetic suspension systems for vibration isolation and pointing applications. The LGMSS features six degrees of freedom and consists of a planar array of electromagnets that levitate and position a cylindrical element containing a permanent magnet core. The OMS provides information on the location and orientation of the element to the LGMSS control system to stabilize suspension. The hardware design of this optical sensing system and the tracking algorithms are presented. The results of analyses and experiments are presented that define the accuracy limits of the optical sensing system and that quantify the errors in position estimation.

  15. The Sequencing Bead Array (SBA), a Next-Generation Digital Suspension Array

    PubMed Central

    Akhras, Michael S.; Pettersson, Erik; Diamond, Lisa; Unemo, Magnus; Okamoto, Jennifer; Davis, Ronald W.; Pourmand, Nader

    2013-01-01

    Here we describe the novel Sequencing Bead Array (SBA), a complete assay for molecular diagnostics and typing applications. SBA is a digital suspension array using Next-Generation Sequencing (NGS), to replace conventional optical readout platforms. The technology allows for reducing the number of instruments required in a laboratory setting, where the same NGS instrument could be employed from whole-genome and targeted sequencing to SBA broad-range biomarker detection and genotyping. As proof-of-concept, a model assay was designed that could distinguish ten Human Papillomavirus (HPV) genotypes associated with cervical cancer progression. SBA was used to genotype 20 cervical tumor samples and, when compared with amplicon pyrosequencing, was able to detect two additional co-infections due to increased sensitivity. We also introduce in-house software Sphix, enabling easy accessibility and interpretation of results. The technology offers a multi-parallel, rapid, robust, and scalable system that is readily adaptable for a multitude of microarray diagnostic and typing applications, e.g. genetic signatures, single nucleotide polymorphisms (SNPs), structural variations, and immunoassays. SBA has the potential to dramatically change the way we perform probe-based applications, and allow for a smooth transition towards the technology offered by genomic sequencing. PMID:24116138

  16. Optical position measurement for a Large Gap Magnetic Suspension System

    NASA Technical Reports Server (NTRS)

    Welch, Sharon S.; Shelton, Kevin J.; Clemmons, James I.

    1991-01-01

    This paper describes the design of an optical position measurement system which is being built as part of the NASA Langley Large Gap Magnetic Suspension System (LGMSS). The LGMSS is a five degree-of-freedom, large-gap magnetic suspension system which is being built for Langley Research Center as part of the Advanced Controls Test Facility (ACTF). The LGMSS consists of a planar array of electromagnets which levitate and position a cylindrically shaped model containing a permanent magnet core. The optical position measurement system provides information on the location and orientation of the model to the LGMSS control system to stabilize levitation of the model.

  17. Sequential Multiplex Analyte Capturing for Phosphoprotein Profiling*

    PubMed Central

    Poetz, Oliver; Henzler, Tanja; Hartmann, Michael; Kazmaier, Cornelia; Templin, Markus F.; Herget, Thomas; Joos, Thomas O.

    2010-01-01

    Microarray-based sandwich immunoassays can simultaneously detect dozens of proteins. However, their use in quantifying large numbers of proteins is hampered by cross-reactivity and incompatibilities caused by the immunoassays themselves. Sequential multiplex analyte capturing addresses these problems by repeatedly probing the same sample with different sets of antibody-coated, magnetic suspension bead arrays. As a miniaturized immunoassay format, suspension bead array-based assays fulfill the criteria of the ambient analyte theory, and our experiments reveal that the analyte concentrations are not significantly changed. The value of sequential multiplex analyte capturing was demonstrated by probing tumor cell line lysates for the abundance of seven different receptor tyrosine kinases and their degree of phosphorylation and by measuring the complex phosphorylation pattern of the epidermal growth factor receptor in the same sample from the same cavity. PMID:20682761

  18. Construction of high-density bacterial colony arrays and patterns by the ink-jet method.

    PubMed

    Xu, Tao; Petridou, Sevastioni; Lee, Eric H; Roth, Elizabeth A; Vyavahare, Narendra R; Hickman, James J; Boland, Thomas

    2004-01-05

    We have developed a method for fabricating bacterial colony arrays and complex patterns using commercially available ink-jet printers. Bacterial colony arrays with a density of 100 colonies/cm(2) were obtained by directly ejecting Escherichia coli (E. coli) onto agar-coated substrates at a rapid arraying speed of 880 spots per second. Adjusting the concentration of bacterial suspensions allowed single colonies of viable bacteria to be obtained. In addition, complex patterns of viable bacteria as well as bacteria density gradients were constructed using desktop printers controlled by a simple software program. Copyright 2003 Wiley Periodicals, Inc.

  19. SNPflow: A Lightweight Application for the Processing, Storing and Automatic Quality Checking of Genotyping Assays

    PubMed Central

    Schönherr, Sebastian; Neuner, Mathias; Forer, Lukas; Specht, Günther; Kloss-Brandstätter, Anita; Kronenberg, Florian; Coassin, Stefan

    2013-01-01

    Single nucleotide polymorphisms (SNPs) play a prominent role in modern genetics. Current genotyping technologies such as Sequenom iPLEX, ABI TaqMan and KBioscience KASPar made the genotyping of huge SNP sets in large populations straightforward and allow the generation of hundreds of thousands of genotypes even in medium sized labs. While data generation is straightforward, the subsequent data conversion, storage and quality control steps are time-consuming, error-prone and require extensive bioinformatic support. In order to ease this tedious process, we developed SNPflow. SNPflow is a lightweight, intuitive and easily deployable application, which processes genotype data from Sequenom MassARRAY (iPLEX) and ABI 7900HT (TaqMan, KASPar) systems and is extendible to other genotyping methods as well. SNPflow automatically converts the raw output files to ready-to-use genotype lists, calculates all standard quality control values such as call rate, expected and real amount of replicates, minor allele frequency, absolute number of discordant replicates, discordance rate and the p-value of the HWE test, checks the plausibility of the observed genotype frequencies by comparing them to HapMap/1000-Genomes, provides a module for the processing of SNPs, which allow sex determination for DNA quality control purposes and, finally, stores all data in a relational database. SNPflow runs on all common operating systems and comes as both stand-alone version and multi-user version for laboratory-wide use. The software, a user manual, screenshots and a screencast illustrating the main features are available at http://genepi-snpflow.i-med.ac.at. PMID:23527209

  20. Effect of soil and water environment on typeability of PowerPlex Y (Promega) in selected tissue samples.

    PubMed

    Niemcunowicz-Janica, Anna; Pepinski, Witold; Janica, Jacek Robert; Skawronska, Malgorzata; Janica, Jerzy; Koc-Zorawska, Ewa; Stolyszewski, Ireneusz

    2007-01-01

    In cases of decomposed bodies Y chromosomal STR markers may be useful in identification of a male relative. The authors assessed typeability PowerPlex Y (Promega) loci in tissue material stored in water and soil environment. Tissue material was collected during autopsies of five persons aged 20-30 years with time of death determined within the limit of 14 hours. Heart muscle, liver and lung specimens were stored in pond water, sea water, sand and peat soil. DNA was extracted by organic method from tissue samples collected in 7-day intervals. Liver specimens were typeable in all PowerPlex Y loci within 100 days of storage in pond water with gradual decline at DYS392 in sea water. Heart muscle specimens stored in pond water exhibited allelic loss at DYS19, DYS385, DYS389II and DYS392, while all loci were typeable in sea water stored samples. For lung specimens allelic loss was noted throughout the profile. Storage of liver specimens in peat soil for more than 14 days resulted in allelic drop-out, and after 21 days no profiles were typeable. Heart muscle specimens were typeable in all PowerPlex Y systems after 35-day storage in sand, while allelic drop-out and subsequent lack of profiles were noted after 14 and 35 days respectively. Lung specimens stored in garden soil exhibited allelic drop-out and subsequent lack of profiles after 7 and 21 days, respectively. All PowerPlex Y loci were typeable in the latter material in sand up to day 35 with gradual decline of longer amplicons (DYS19, DYS385, DYS389II and DYS392).

  1. Motion stability of the magnetic levitation and suspension with YBa2Cu3O7-x high-Tc superconducting bulks and NdFeB magnets

    NASA Astrophysics Data System (ADS)

    Li, Jipeng; Zheng, Jun; Huang, Huan; Li, Yanxing; Li, Haitao; Deng, Zigang

    2017-10-01

    The flux pinning effect of YBa2Cu3O7-x high temperature superconducting (HTS) bulk can achieve self-stable levitation over a permanent magnet or magnet array. Devices based on this phenomenon have been widely developed. However, the self-stable flux pinning effect is not unconditional, under disturbances, for example. To disclose the roots of this amazing self-stable levitation phenomenon in theory, mathematical and mechanical calculations using Lyapunov's stability theorem and the Hurwitz criterion were performed under the conditions of magnetic levitation and suspension of HTS bulk near permanent magnets in Halbach array. It is found that the whole dynamical system, in the case of levitation, has only one equilibrium solution, and the singular point is a stable focus. In the general case of suspension, the system has two singular points: one is a stable focus, and the other is an unstable saddle. With the variation of suspension force, the two first-order singular points mentioned earlier will get closer and closer, and finally degenerate to a high-order singular point, which means the stable region gets smaller and smaller, and finally vanishes. According to the center manifold theorem, the high-order singular point is unstable. With the interaction force varying, the HTS suspension dynamical system undergoes a saddle-node bifurcation. Moreover, a deficient damping can also decrease the stable region. These findings, together with existing experiments, could enlighten the improvement of HTS devices with strong anti-interference ability.

  2. A High Sensitivity Bio Photosensor for Detecting a Luciferase Bioluminescence

    NASA Astrophysics Data System (ADS)

    Kameda, Seiji; Moriyama, Yusuke; Noda, Kenichi; Iwata, Atsushi

    A high sensitivity CMOS bio photosensor applicable to a bioluminescent assay was developed with a 0.18µm CMOS image sensor (CIS) process. The bio photosensor consisting of a photosensor and a PWM 20bit A/D converter achieved high sensitivity for detecting a extremely low bioluminescence due to a large photodiode area, a long exposure time and the other noise reduction techniques. The bio photosensor chip has a 2×4 sensor array on a 2.45×2.45mm2 die. Experimental results with the bioluminescence showed the chip can detect below 10-5lux luminescence at room temperature and the power consumption is 32µW.

  3. Increased 18F-FDG Uptake Is Predictive of Rupture in a Novel Rat Abdominal Aortic Aneurysm Rupture Model

    PubMed Central

    English, Sean J.; Piert, Morand R.; Diaz, Jose A.; Gordon, David; Ghosh, Abhijit; D'Alecy, Louis G.; Whitesall, Steven E.; Sharma, Ashish K.; DeRoo, Elise P.; Watt, Tessa; Su, Gang; Henke, Peter K.; Eliason, Jonathan L.; Ailawadi, Gorav; Upchurch, Gilbert R.

    2015-01-01

    Objective To determine whether 18F-fluorodeoxyglucose (18F-FDG) micro–positron emission tomography (micro-PET) can predict abdominal aortic aneurysm (AAA) rupture. Background An infrarenal AAA model is needed to study inflammatory mechanisms that drive rupture. 18F-FDG PET can detect vascular inflammation in animal models and patients. Methods After exposing Sprague-Dawley rats to intra-aortic porcine pancreatic elastase (PPE) (12 U/mL), AAA rupture was induced by daily, subcutaneous, β-aminopropionitrile (BAPN, 300 mg/kg, N = 24) administration. Negative control AAA animals (N = 15) underwent daily saline subcutaneous injection after PPE exposure. BAPN-exposed animals that did not rupture served as positive controls [nonruptured AAA (NRAAA) 14d, N = 9]. Rupture was witnessed using radiotelemetry. Maximum standard uptakes for 18F-FDG micro-PET studies were determined. Aortic wall PAI-1, uPA, and tPA concentrations were determined by western blot analyses. Interleukin (IL)-1β, IL-6, IL-10, and MIP-2 were determined by Bio-Plex bead array. Neutrophil and macrophage populations per high-power field were quantified. Matrix metalloproteinase (MMP) activities were determined by zymography. Results When comparing ruptured AAA (RAAA) to NRAAA 14d animals, increased focal 18F-FDG uptakes were detected at subsequent sites of rupture (P = 0.03). PAI-1 expression was significantly less in RAAA tissue (P = 0.01), with comparable uPA and decreased tPA levels (P = 0.02). IL-1β (P = 0.04), IL-6 (P = 0.001), IL-10 (P = 0.04), and MIP-2 (P = 0.02)expression, neutrophil (P = 0.02) and macrophage presence (P = 0.002), and MMP9 (P < 0.0001) activity were increased in RAAA tissue. Conclusions With this AAA rupture model, increased prerupture 18F-FDG uptake on micro-PET imaging was associated with increased inflammation in the ruptured AAA wall. 18F-FDG PET imaging may be used to monitor inflammatory changes before AAA rupture. PMID:24651130

  4. Mass spectrometry: a revolution in clinical microbiology?

    PubMed

    Lavigne, Jean-Philippe; Espinal, Paula; Dunyach-Remy, Catherine; Messad, Nourredine; Pantel, Alix; Sotto, Albert

    2013-02-01

    Recently, different bacteriological laboratory interventions that decrease reporting time have been developed. These promising new broad-based techniques have merit, based on their ability to identify rapidly many bacteria, organisms difficult to grow or newly emerging strains, as well as their capacity to track disease transmission. The benefit of rapid reporting of identification and/or resistance of bacteria can greatly impact patient outcomes, with an improvement in the use of antibiotics, in the reduction of the emergence of multidrug resistant bacteria and in mortality rates. Different techniques revolve around mass spectrometry (MS) technology: matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), PCR combined with electrospray ionization-mass spectrometry (PCR/ESIMS), iPLEX MassArray system and other new evolutions combining different techniques. This report emphasizes the (r)evolution of these technologies in clinical microbiology.

  5. Non-Cell-Adhesive Substrates for Printing of Arrayed Biomaterials

    PubMed Central

    Appel, Eric A.; Larson, Benjamin L.; Luly, Kathryn M.; Kim, Jinseong D.

    2015-01-01

    Cellular microarrays have become extremely useful in expediting the investigation of large libraries of (bio)materials for both in vitro and in vivo biomedical applications. We have developed an exceedingly simple strategy for the fabrication of non-cell-adhesive substrates supporting the immobilization of diverse (bio)material features, including both monomeric and polymeric adhesion molecules (e.g. RGD and polylysine), hydrogels, and polymers. PMID:25430948

  6. Mixing and segregation of microspheres in microchannel flows of mono- and bidispersed suspensions

    NASA Astrophysics Data System (ADS)

    Gao, C.; Xu, B.; Gilchrist, J. F.

    2009-03-01

    We investigate the mixing and segregation of mono- and bidispersed microsphere suspensions in microchannel flows. These flows are common in biological microelectromechanical systems (BioMEMS) applications handling blood or suspensions of DNA. Suspension transport in pressure driven flows is significantly hindered by shear-induced migration, where particles migrate away from the walls and are focused in the center due to multibody hydrodynamic interactions. The microchannels used in this study have geometries that induce chaotic advection in Newtonian fluids. Our results show that mixing in straight, herringbone and staggered herringbone channels depends strongly on volume fraction. Due to this complex interplay of advection and shear-induced migration, a staggered herringbone channel that typically results in chaotic mixing is not always effective for dispersing particles. The maximum degree of segregation is observed in a straight channel once the maximum packing fraction is reached at channel center. We modify a one-dimensional suspension balance model [R. Miller and J. Morris, J. Non-Newtonian Fluid Mech. 135, 149 (2006)] to describe the behavior at the center of the straight channel. The degree of mixing is then calculated as a function of bulk volume fraction, predicting the volume fraction that results in the maximum degree of segregation. In bidispersed suspension flow, it is shown that mixing of the larger species is enhanced in straight and staggered herringbone channels while segregation is enhanced at moderate volume fractions in herringbone channels. This suggests mixing and separations can be tailored by adjusting both the suspension properties and the channel geometry.

  7. Effect of a formulation of Bacillus firmus on root-knot nematode Meloidogyne incognita infestation and the growth of tomato plants in the greenhouse and nursery.

    PubMed

    Terefe, Metasebia; Tefera, Tadele; Sakhuja, P K

    2009-02-01

    Bacillus firmus, commercial WP formulation (BioNem) was evaluated against the root-knot nematode Meloidogyne incognita in a laboratory, greenhouse and under field conditions on tomato plants. In the laboratory tests, an aqueous suspension of BioNem at 0.5%, 1%, 1.5% and 2% concentration reduced egg hatching from 98% to 100%, 24-days after treatment. Treatment of second-stage juveniles with 2.5% and 3% concentration of BioNem, caused 100% inhibition of mobility, 24 h after treatment. In the green house trials, BioNem applied at 8 g/pot (1200 cc soil) planted with a tomato seedlings reduced gall formation by 91%, final nematode populations by 76% and the number of eggs by 45%. Consequently, plant height and biomass was increased by 71% and 50%, respectively, compared to the untreated control, 50-days after treatment application. Application of BioNem at 16 g/pot was phytotoxic to plants. In the field trails, BioNem applied at 200 and 400 kg ha(-1) was effective in reducing the number of galls (75-84%), and increased shoot height (29-31%) and weight (20-24%) over the untreated control, 45-days after treatment. Our results indicate that B. firmus is a promising microorganism for the biological control of M. incognita in tomato pots.

  8. Method of fabricating high-density hermetic electrical feedthroughs

    DOEpatents

    Shah, Kedar G.; Pannu, Satinderpall S.; Delima, Terri L.

    2015-06-02

    A method of fabricating electrical feedthroughs selectively removes substrate material from a first side of an electrically conductive substrate (e.g. a bio-compatible metal) to form an array of electrically conductive posts in a substrate cavity. An electrically insulating material (e.g. a bio-compatible sealing glass) is then flowed to fill the substrate cavity and surround each post, and solidified. The solidified insulating material is then exposed from an opposite second side of the substrate so that each post is electrically isolated from each other as well as the bulk substrate. In this manner a hermetic electrically conductive feedthrough construction is formed having an array of electrical feedthroughs extending between the first and second sides of the substrate from which it was formed.

  9. Nanoscopic Electrofocusing for Bio-Nanoelectronic Devices

    NASA Astrophysics Data System (ADS)

    Lakshmanan, Shanmugamurthy

    2015-01-01

    The ability to arrange precisely designed patterns of nanoparticles into a desired spatial configuration is the key to creating novel nanoscale devices that take advantage of the unique properties of nanomaterials. While two-dimensional arrays of nanoparticles have been demonstrated successfully by various techniques, a controlled way of building ordered arrays of three-dimensional (3D) nanoparticle structures remains challenging. This book describes a new technique called the 'nanoscopic lens' which is able to produce a variety of 3D nano-structures in a controlled manner. This ebook describes the nanoscopic lens technique and how it can serve as the foundation for device development that is not limited to a variety of optical, magnetic and electronic devices, but can also create a wide range of bio-nanoelectronic devices.

  10. A comparative study of the effect of Bio-Oss® in combination with concentrated growth factors or bone marrow-derived mesenchymal stem cells in canine sinus grafting.

    PubMed

    Wang, Fang; Li, Qiong; Wang, Zuolin

    2017-08-01

    To compare the effects of Bio-Oss ® in combination with concentrated growth factors (CGFs) and bone marrow-derived mesenchymal stem cells (BMSCs) on bone regeneration for maxillary sinus floor augmentation in beagle dogs. Six beagle dogs received bilateral maxillary sinus floor augmentation. Venous blood drawn from dogs was collected and centrifuged to obtain CGFs. BMSCs derived from canine bone marrow were cultured using density gradient centrifugation. The suspension of BMSCs was added onto Bio-Oss ® granules at a density of 2 × 10 6 cells/ml, and the BMSCs/Bio-Oss ® constructs were incubated for an additional 4 h before use. Twelve sinuses were grafted with a mixture of CGFs/Bio-Oss ® , BMSCs/Bio-Oss ® construct, or Bio-Oss ® alone. Six months later, the bone formation of bilateral sinuses was evaluated by Micro-CT, microhardness test, histological examination, and histomorphometry. No adverse effect was found in these dogs. The dome-shaped augmentation protruded into the sinus cavity. Micro-CT revealed that there was significant difference in BV/TV but not in Tb. N, between groups A, B, and C. The extent of microhardness in groups A and B was significantly higher than in group C. The proportion of newly formed bone in groups A and B showed significant difference when compared to group C (P ≤ 0.01). The amount of residual grafts in groups A and B was significantly lower than in group C. Grafting with Bio-Oss ® in combination with CGFs can increase new bone formation more efficiently than using Bio-Oss ® alone in a canine model. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. High-performance flexible strain sensor with bio-inspired crack arrays.

    PubMed

    Han, Zhiwu; Liu, Linpeng; Zhang, Junqiu; Han, Qigang; Wang, Kejun; Song, Honglie; Wang, Ze; Jiao, Zhibin; Niu, Shichao; Ren, Luquan

    2018-06-12

    Biomimetic sensor technology is always superior to existing human technologies. The scorpion, especially the forest scorpion, has a unique ability to detect subtle vibrations, which is attributed to the microcrack-shaped slit sensillum on its legs. Here, the biological sensing mechanism of the typical scorpion (Heterometrus petersii) was intensively studied in order to newly design and significantly improve the flexible strain sensors. Benefiting from the easy-crack property of polystyrene (PS) and using the solvent-induced swelling as well as double template transferring method, regular and controllable microcrack arrays were successfully fabricated on top of polydimethylsiloxane (PDMS). Using this method, any physical damage to PDMS could be effectively avoided. More fortunately, this bio-inspired crack arrays fabricated in this work also had a radial-like pattern similar to the slit sensillum of the scorpion, which was another unexpected imitation. The gauge factor (GF) of the sensor was conservatively evaluated at 5888.89 upon 2% strain and the response time was 297 ms. Afterward, it was demonstrated that the bio-inspired regular microcrack arrays could also significantly enhance the performance of traditional strain sensors, especially in terms of the sensitivity and response time. The practical applications, such as the detection of human motions and surface folding, were also tested in this work, with the results showing significant potential applications in numerous fields. This work changes the traditional waste cracks on some damaged products into valuable things for ultrasensitive mechanical sensors. Moreover, with this manufacturing technique, we could easily realize the simple, low cost and large-scale fabrication of advanced bioinpired sensors.

  12. Micro-hole array fluorescent sensor based on AC-Dielectrophoresis (DEP) for simultaneous analysis of nano-molecules

    NASA Astrophysics Data System (ADS)

    Kim, Hye Jin; Kang, Dong-Hoon; Lee, Eunji; Hwang, Kyo Seon; Shin, Hyun-Joon; Kim, Jinsik

    2018-02-01

    We propose a simple fluorescent bio-chip based on two types of alternative current-dielectrophoretic (AC-DEP) force, attractive (positive DEP) and repulsive (negative DEP) force, for simultaneous nano-molecules analysis. Various radius of micro-holes on the bio-chip are designed to apply the different AC-DEP forces, and the nano-molecules are concentrated inside the micro-hole arrays according to the intensity of the DEP force. The bio-chip was fabricated by Micro Electro Mechanical system (MEMS) technique, and was composed of two layers; a SiO2 layer and Ta/Pt layer were accomplished for an insulation layer and a top electrode with micro-hole arrays to apply electric fields for DEP force, respectively. Each SiO2 and Ta/Pt layers were deposited by thermal oxidation and sputtering, and micro-hole arrays were fabricated with Inductively Coupled Plasma (ICP) etching process. For generation of each positive and negative DEP at micro-holes, we applied two types of sine-wave AC voltage with different frequency range alternately. The intensity of the DEP force was controlled by the radius of the micro-hole and size of nano-molecule, and calculated with COMSOL multi-physics. Three types of nano-molecules labelled with different fluorescent dye were used and the intensity of nano-molecules was examined by the fluorescent optical analysis after applying the DEP force. By analyzing the fluorescent intensities of the nano-molecules, we verify the various nano-molecules in analyte are located successfully inside corresponding micro-holes with different radius according to their size.

  13. Development of a rapid 21-plex autosomal STR typing system for forensic applications.

    PubMed

    Yang, Meng; Yin, Caiyong; Lv, Yuexin; Yang, Yaran; Chen, Jing; Yu, Zailiang; Liu, Xu; Xu, Meibo; Chen, Feng; Wu, Huijuan; Yan, Jiangwei

    2016-10-01

    DNA-STR genotyping technology has been widely used in forensic investigations. Even with such success, there is a great need to reduce the analysis time. In this study, we established a new rapid 21-plex STR typing system, including 13 CODIS loci, Penta D, Penta E, D12S391, D2S1338, D6S1043, D19S433, D2S441 and Amelogenin loci. This system could shorten the amplification time to a minimum of 90 min and does not require DNA extraction from the samples. Validation of the typing system complied with the Scientific Working Group on DNA Analysis Methods (SWGDAM) and the Chinese National Standard (GA/T815-2009) guidelines. The results demonstrated that this 21-plex STR typing system was a valuable tool for rapid criminal investigation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Diazonium Chemistry for the Bio-Functionalization of Glassy Nanostring Resonator Arrays

    PubMed Central

    Zheng, Wei; Du, Rongbing; Cao, Yong; Mohammad, Mohammad A.; Dew, Steven K.; McDermott, Mark T.; Evoy, Stephane

    2015-01-01

    Resonant glassy nanostrings have been employed for the detection of biomolecules. These devices offer high sensitivity and amenability to large array integration and multiplexed assays. Such a concept has however been impaired by the lack of stable and biocompatible linker chemistries. Diazonium salt reduction-induced aryl grafting is an aqueous-based process providing strong chemical adhesion. In this work, diazonium-based linker chemistry was performed for the first time on glassy nanostrings, which enabled the bio-functionalization of such devices. Large arrays of nanostrings with ultra-narrow widths down to 10 nm were fabricated employing electron beam lithography. Diazonium modification was first developed on SiCN surfaces and validated by X-ray photoelectron spectroscopy. Similarly modified nanostrings were then covalently functionalized with anti-rabbit IgG as a molecular probe. Specific enumeration of rabbit IgG was successfully performed through observation of downshifts of resonant frequencies. The specificity of this enumeration was confirmed through proper negative control experiments. Helium ion microscopy further verified the successful functionalization of nanostrings. PMID:26263989

  15. Diazonium Chemistry for the Bio-Functionalization of Glassy Nanostring Resonator Arrays.

    PubMed

    Zheng, Wei; Du, Rongbing; Cao, Yong; Mohammad, Mohammad A; Dew, Steven K; McDermott, Mark T; Evoy, Stephane

    2015-07-30

    Resonant glassy nanostrings have been employed for the detection of biomolecules. These devices offer high sensitivity and amenability to large array integration and multiplexed assays. Such a concept has however been impaired by the lack of stable and biocompatible linker chemistries. Diazonium salt reduction-induced aryl grafting is an aqueous-based process providing strong chemical adhesion. In this work, diazonium-based linker chemistry was performed for the first time on glassy nanostrings, which enabled the bio-functionalization of such devices. Large arrays of nanostrings with ultra-narrow widths down to 10 nm were fabricated employing electron beam lithography. Diazonium modification was first developed on SiCN surfaces and validated by X-ray photoelectron spectroscopy. Similarly modified nanostrings were then covalently functionalized with anti-rabbit IgG as a molecular probe. Specific enumeration of rabbit IgG was successfully performed through observation of downshifts of resonant frequencies. The specificity of this enumeration was confirmed through proper negative control experiments. Helium ion microscopy further verified the successful functionalization of nanostrings.

  16. Microfluidic device for the assembly and transport of microparticles

    DOEpatents

    James, Conrad D [Albuquerque, NM; Kumar, Anil [Framingham, MA; Khusid, Boris [New Providence, NJ; Acrivos, Andreas [Stanford, CA

    2010-06-29

    A microfluidic device comprising independently addressable arrays of interdigitated electrodes can be used to assembly and transport large-scale microparticle structures. The device and method uses collective phenomena in a negatively polarized suspension exposed to a high-gradient strong ac electric field to assemble the particles into predetermined locations and then transport them collectively to a work area for final assembly by sequentially energizing the electrode arrays.

  17. Mechanical Design of a 4-Stage ADR for the PIPER mission

    NASA Technical Reports Server (NTRS)

    James, Bryan L.; Kimball, Mark O.; Shirron, Peter J.; Sampson, Michael A.; Letmate, Richard V.; Jackson, Michael L.

    2017-01-01

    The four 1,280 bolometer detector arrays that will fly on the balloon borne PIPER mission will be cooled by a 4-stage adiabatic demagnetization refrigerator (ADR). Two of the three mechanically independent ADR assemblies provide thermal isolation to their salt pills through Kevlar suspensions while the other provides thermal isolation to its salt pill through the use of bellows and Vespel material. The ADR integrates with the detector arrays and it sits in a large bucket Dewar containing superfluid liquid helium. This paper will describe the complex mechanical design of the PIPER ADR, and summarize the mechanical analysis done to validate the design.The four 1,280 bolometer detector arrays that will fly on the balloon borne PIPER mission will be cooled by a 4-stage adiabatic demagnetization refrigerator (ADR). Two of the three mechanically independent ADR assemblies provide thermal isolation to their salt pills through Kevlar suspensions while the other provides thermal isolation to its salt pill through the use of bellows and Vespel material. The ADR integrates with the detector arrays and it sits in a large bucket Dewar containing superfluid liquid helium. This paper will describe the complex mechanical design of the PIPER ADR, and summarize the mechanical analysis done to validate the design.

  18. Nanoband array electrode as a platform for high sensitivity enzyme-based glucose biosensing.

    PubMed

    Falk, Magnus; Sultana, Reshma; Swann, Marcus J; Mount, Andrew R; Freeman, Neville J

    2016-12-01

    We describe a novel glucose biosensor based on a nanoband array electrode design, manufactured using standard semiconductor processing techniques, and bio-modified with glucose oxidase immobilized at the nanoband electrode surface. The nanoband array architecture allows for efficient diffusion of glucose and oxygen to the electrode, resulting in a thousand-fold improvement in sensitivity and wide linear range compared to a conventional electrode. The electrode constitutes a robust and manufacturable sensing platform. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Excited State Energetics and Dynamics of Large Molecules, Complexes and Clusters

    DTIC Science & Technology

    1988-07-01

    tetracene. Ar (n=l-5) complexes, providing central information on microscopic solvent shifts. These studies were extended to M-metal atom com - plexes...corresponding to the bare molecule. At higher 2. Experimental stagnation pressures of Ar (p = 80-150 Toff) the contributions of van der Waals DPB. Ar, com - Our...gas aromatic-molecule complexes were docu- So - S1 transition of the trans-stilbene (TS)-Ar com - mented experimentally to lie in the rango - 30- plex

  20. [Efficiency of 27-plex single nucleotide polymorphism multiplex system for ancestry inference in different populations].

    PubMed

    Feng, Xing-Ling; Sun, Qi-Fan; Liu, Hong; Wei, Yi-Liang; DU, Wei-An; Li, Cai-Xia; Chen, Ling; Liu, Chao

    2016-04-20

    To validate the efficiency of 27-plex single nucleotide polymorphism (SNP) multiplex system for ancestry inference. The 27-plex SNP system was validated for its sensitivity and species specificity. A total of 533 samples were collected from African, Southern Chinese Han, China's ethic minorities (Yi, Hui, Miao, Tibet, and Uygur), European, Central Asian, Western Asian, Southern Asian, Southeast Asian and South American populations for clustering analysis of the genotypes by citing 3 representative continental ancestral groups [East Asia (CHB), Europe (CEU), and Africa (YRI)] from HapMap database. The system sensitivity is 0.125 ng. Twenty and six genotypes were detected in chimpanzee and monkeys, respectively. Except in rs10496971, no more products were found in other animals. The system was capable of differentiating intercontinental populations but not of distinguishing between East Asian and Southeast Asian population or between Southern Chinese Han population and Chinese Ethnic populations (Hui, Miao, Yi and Tibet). This system achieved a 100% accuracy for intercontinental population source inference for 46 blind test samples. 27-plex SNPs multiplex system has a high sensitivity and species specificity and can correctly differentiate the ancestry origins of individuals from African, European and East Asian for criminal case investigation. But this system is not capable of distinguishing subpopulation groups and more specific ancestry-informative markers are needed to improve its recognition of Southeast Asian and Chinese ethnic populations.

  1. Bio-Inspired Controllable Adhesive

    DTIC Science & Technology

    2008-12-01

    pad of the tarsus – which act as a sort of hydraulic suspension. The lamellae contain rows of thin slender fibers , called setae, approximately 130 µm...in length and 20 µm in diameter (Hildebrand, 1988), Fig.1. The terminus of each seta branches into thousands of smaller fibers , or spatular stalks...ADHESION TESTING The structures were characterized (Northen et al., 2008) using a home-built adhesion test apparatus ( Basalt - II) with C. Greiner

  2. Controlling Non-Equilibrium Structure Formation on the Nanoscale.

    PubMed

    Buchmann, Benedikt; Hecht, Fabian Manfred; Pernpeintner, Carla; Lohmueller, Theobald; Bausch, Andreas R

    2017-12-06

    Controlling the structure formation of gold nanoparticle aggregates is a promising approach towards novel applications in many fields, ranging from (bio)sensing to (bio)imaging to medical diagnostics and therapeutics. To steer structure formation, the DNA-DNA interactions of DNA strands that are coated on the surface of the particles have become a valuable tool to achieve precise control over the interparticle potentials. In equilibrium approaches, this technique is commonly used to study particle crystallization and ligand binding. However, regulating the structural growth processes from the nano- to the micro- and mesoscale remains elusive. Here, we show that the non-equilibrium structure formation of gold nanoparticles can be stirred in a binary heterocoagulation process to generate nanoparticle clusters of different sizes. The gold nanoparticles are coated with sticky single stranded DNA and mixed at different stoichiometries and sizes. This not only allows for structural control but also yields access to the optical properties of the nanoparticle suspensions. As a result, we were able to reliably control the kinetic structure formation process to produce cluster sizes between tens of nanometers up to micrometers. Consequently, the intricate optical properties of the gold nanoparticles could be utilized to control the maximum of the nanoparticle suspension extinction spectra between 525 nm and 600 nm. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Nanoblinker: Brownian Motion Powered Bio-Nanomachine for FRET Detection of Phagocytic Phase of Apoptosis

    PubMed Central

    Minchew, Candace L.; Didenko, Vladimir V.

    2014-01-01

    We describe a new type of bio-nanomachine which runs on thermal noise. The machine is solely powered by the random motion of water molecules in its environment and does not ever require re-fuelling. The construct, which is made of DNA and vaccinia virus topoisomerase protein, can detect DNA damage by employing fluorescence. It uses Brownian motion as a cyclic motor to continually separate and bring together two types of fluorescent hairpins participating in FRET. This bio-molecular oscillator is a fast and specific sensor of 5′OH double-strand DNA breaks present in phagocytic phase of apoptosis. The detection takes 30 s in solution and 3 min in cell suspensions. The phagocytic phase is critical for the effective execution of apoptosis as it ensures complete degradation of the dying cells’ DNA, preventing release of pathological, viral and tumor DNA and self-immunization. The construct can be used as a smart FRET probe in studies of cell death and phagocytosis. PMID:25268504

  4. Identification of carbapenem-resistant Pseudomonas aeruginosa in selected hospitals of the Gulf Cooperation Council States: dominance of high-risk clones in the region.

    PubMed

    Zowawi, Hosam M; Syrmis, Melanie W; Kidd, Timothy J; Balkhy, Hanan H; Walsh, Timothy R; Al Johani, Sameera M; Al Jindan, Reem Y; Alfaresi, Mubarak; Ibrahim, Emad; Al-Jardani, Amina; Al Salman, Jameela; Dashti, Ali A; Sidjabat, Hanna E; Baz, Omar; Trembizki, Ella; Whiley, David M; Paterson, David L

    2018-04-17

    The molecular epidemiology and resistance mechanisms of carbapenem-resistant Pseudomonas aeruginosa (CRPA) were determined in hospitals in the countries of the Gulf Cooperation Council (GCC), namely, Saudi Arabia, the United Arab Emirates, Oman, Qatar, Bahrain and Kuwait. Isolates were screened for common carbapenem-resistance genes by PCR. Relatedness between isolates was assessed using previously described genotyping methods: an informative-single nucleotide polymorphism MassARRAY iPLEX assay (iPLEX20SNP) and the enterobacterial repetitive intergenic consensus (ERIC)-PCR assay, with selected isolates being subjected to multilocus sequence typing (MLST). Ninety-five non-repetitive isolates that were found to be resistant to carbapenems were subjected to further investigation.Results/Key findings. The most prevalent carbapenemase-encoding gene, blaVIM-type, was found in 37/95 (39 %) isolates, while only 1 isolate (from UAE) was found to have blaIMP-type. None of the CRPA were found to have blaNDM-type or blaKPC-type. We found a total of 14 sequence type (ST) clusters, with 4 of these clusters being observed in more than 1 country. Several clusters belonged to the previously recognized internationally disseminated high-risk clones ST357, ST235, ST111, ST233 and ST654. We also found the less predominant ST316, ST308 and ST823 clones, and novel MLST types (ST2010, ST2011, ST2012 and ST2013), in our collection. Overall our data show that 'high-risk' CRPA clones are now detected in the region and highlight the need for strategies to limit further spread of such organisms, including enhanced surveillance, infection control precautions and further promotion of antibiotic stewardship programmes.

  5. Habitability as a Tier One Criterion in Exploration Mission and Vehicle Design. Part 1; Habitability

    NASA Technical Reports Server (NTRS)

    Adams, Constance M.; McCurdy, Matthew Riegel

    1999-01-01

    Habitability and human factors are necessary criteria to include in the iterative process of Tier I mission design. Bringing these criteria in at the first, conceptual stage of design for exploration and other human-rated missions can greatly reduce mission development costs, raise the level of efficiency and viability, and improve the chances of success. In offering a rationale for this argument, the authors give an example of how the habitability expert can contribute to early mission and vehicle architecture by defining the formal implications of a habitable vehicle, assessing the viability of units already proposed for exploration missions on the basis of these criteria, and finally, by offering an optimal set of solutions for an example mission. In this, the first of three papers, we summarize the basic factors associated with habitability, delineate their formal implications for crew accommodations in a long-duration environment, and show examples of how these principles have been applied in two projects at NASA's Johnson Space Center: the BIO-Plex test facility, and TransHab.

  6. Needle echogenicity in ultrasound-guided lumbar spine injections: a cadaveric study.

    PubMed

    Gofeld, Michael; Krashin, Daniel L; Ahn, Sangmin

    2013-01-01

    Echogenicity of regional anesthesia needles has been tested on different preclinical models; however, previous studies were done in an ideal experimental setting utilizing high-frequency insonation and superficially located targets. Because steep-angle deep injections are typically required for spinal and other chronic pain procedures, and low-frequency transducers are used, further feasibility study is warranted. To determine effectiveness of steep-angle deep injections, typically required for spinal and other chronic pain procedures. Experimental laboratory study. Willed Body Program, University of Washington. In-plane lumbar spine procedures with 50° and 70° angles were performed on a human cadaver. The images and video clips of a non-echogenic (Quincke-type) and echogenic (SonoPlex, StimuQuick, and EchoStim) needle placements were presented to 3 blinded assessors who rated the needle visibility on a 4-point scale. The data was statistically analyzed to determine the differences in visibility between the needles with and without the digital image enhancement, and to compare the video clips to captured images. ANOVA analysis demonstrated that overall SonoPlex was significantly better (P = 0.02) than other needles. SonoPlex maintained its superiority in the subset of facet joint injections (P = 0.02), followed by Quincke-type, then the StimuQuik, and EchoStim needles. In deep procedures, EchoStim was comparable with SonoPlex (P = 0.03), and they both were better than the other 2 needles. The enhanced images received higher rates, with a 0.6 point mean improved rating (P = 0). This study is limited by choice of needles, number of experiments performed, and potential postmortem changes of echogenicity. The SonoPlex needle appeared to have better echogenicity in this study. While non-echogenic Quincke-type needle visibility was adequate in superficial placements, it was limited in deep injections. An imaging enhancement is effective in improving needle visibility and should be used whenever possible.

  7. Concordance and population studies along with stutter and peak height ratio analysis for the PowerPlex ® ESX 17 and ESI 17 Systems.

    PubMed

    Hill, Carolyn R; Duewer, David L; Kline, Margaret C; Sprecher, Cynthia J; McLaren, Robert S; Rabbach, Dawn R; Krenke, Benjamin E; Ensenberger, Martin G; Fulmer, Patricia M; Storts, Douglas R; Butler, John M

    2011-08-01

    The PowerPlex(®) ESX 17 and ESI 17 Systems for short tandem repeat (STR) amplification were developed by the Promega Corporation to meet the European Network of Forensic Science Institutes (ENFSI) and the European DNA Profiling (EDNAP) Group recommendations for increasing the number of STR loci included in the European Standard Set (ESS). The PowerPlex ESX 17 and ESI 17 Systems utilize different PCR primer combinations to co-amplify the following 17 loci: D1S1656, D2S441, D2S1338, D3S1358, D8S1179, D10S1248, D12S391, D16S539, D18S51, D19S433, D21S11, D22S1045, FGA, TH01, vWA, SE33, and the sex-typing locus amelogenin. A total of 1443 U.S. population samples were evaluated with pre-commercialization versions of both kits. Stutter and heterozygote peak height ratios have been used to characterize kit performance. Typing results have been used to estimate the match probabilities provided by the chosen loci as well as in concordance studies. Full concordance between the typing results for the two kits was observed in 99.994% (49,055 out of 49,062) STR allele calls compared. All genotyping discrepancies were confirmed by DNA sequence analysis. As a result of these comparisons, a second forward primer for the D22S1045 locus has been added to the PowerPlex ESX 17 System to address a primer binding site mutation and the D1S1656 locus reverse primer in the PowerPlex ESI 17 System was modified to eliminate an amplification-efficiency reducing primer dimer. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Developmental validation of the PowerPlex(®) 21 System.

    PubMed

    Ensenberger, Martin G; Hill, Carolyn R; McLaren, Robert S; Sprecher, Cynthia J; Storts, Douglas R

    2014-03-01

    The PowerPlex(®) 21 System is a STR multiplex that has been optimized for casework samples while still being capable of database workflows including direct amplification. The loci included in the multiplex offer increasing overlap with core loci used in different countries and regions throughout the world. The PowerPlex(®) 21 System contains D1S1656, D2S1338, D3S1358, D5S818, D6S1043, D7S820, D8S1179, D12S391, D13S317, D16S539, D18S51, D19S433, D21S11, Amelogenin, CSF1PO, FGA, Penta D, Penta E, TH01, TPOX, and vWA. These loci represent all 13 core CODIS loci in addition to loci commonly used in Asia and Europe. A developmental validation study was completed to document performance capabilities and limitations of the PowerPlex(®) 21 System. Data from this validation work served as the basis for the following conclusions: genotyping of single-source samples was reliable across a range of template DNA concentrations with >95% alleles called at 50 pg. Direct amplification of samples from FTA(®) storage cards was successfully performed using the reagents provided with the system and modified cycling protocols provided in the technical manual. Mixture analysis showed that over 95% of minor alleles were detected at 1:9 ratios. Reaction conditions including volume and annealing temperature as well as the concentrations of primers, DNA polymerase, magnesium, and Master Mix were shown to be optimal and able to withstand moderate variations without affecting system performance. Reproducible results were generated by different users at different sites. Finally, concordance studies showed consistent results when comparing the PowerPlex(®) 21 System with other commercially available STR-genotyping systems. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. A conference report from "Down Under": Talking autophagy at OzBio2010.

    PubMed

    Mijaljica, Dalibor; Devenish, Rodney J

    2011-02-01

    OzBio2010 was held at the Melbourne Convention and Exhibition Centre, September 26 to October 1, 2010. This international conference catered to researchers in several fields having complementary interests including biochemistry, molecular biology, cell biology, plant physiology and health-related research. It was held under the auspices of two major international scientific societies, IUBMB and FAOBMB, and the ComBio2010 collective (representing nine professional societies and groupings from Australia). A number of pre-eminent speakers presented at plenary sessions and in a wide array of specialist symposia. One of the plenary sessions and a specialist symposium highlighted autophagy-related topics.

  10. Designing Uniquely Addressable Bio-orthogonal Synthetic Scaffolds for DNA and RNA Origami.

    PubMed

    Kozyra, Jerzy; Ceccarelli, Alessandro; Torelli, Emanuela; Lopiccolo, Annunziata; Gu, Jing-Ying; Fellermann, Harold; Stimming, Ulrich; Krasnogor, Natalio

    2017-07-21

    Nanotechnology and synthetic biology are rapidly converging, with DNA origami being one of the leading bridging technologies. DNA origami was shown to work well in a wide array of biotic environments. However, the large majority of extant DNA origami scaffolds utilize bacteriophages or plasmid sequences thus severely limiting its future applicability as a bio-orthogonal nanotechnology platform. In this paper we present the design of biologically inert (i.e., "bio-orthogonal") origami scaffolds. The synthetic scaffolds have the additional advantage of being uniquely addressable (unlike biologically derived ones) and hence are better optimized for high-yield folding. We demonstrate our fully synthetic scaffold design with both DNA and RNA origamis and describe a protocol to produce these bio-orthogonal and uniquely addressable origami scaffolds.

  11. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    PubMed

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  12. Constructing STR multiplexes for individual identification of Hungarian red deer.

    PubMed

    Szabolcsi, Zoltan; Egyed, Balazs; Zenke, Petra; Padar, Zsolt; Borsy, Adrienn; Steger, Viktor; Pasztor, Erzsebet; Csanyi, Sandor; Buzas, Zsuzsanna; Orosz, Laszlo

    2014-07-01

    Red deer is the most valuable game of the fauna in Hungary, and there is a strong need for genetic identification of individuals. For this purpose, 10 tetranucleotide STR markers were developed and amplified in two 5-plex systems. The study presented here includes the flanking region sequence analysis and the allele nomenclature of the 10 loci as well as the PCR optimization of the DeerPlex I and II. LD pairwise tests and cross-species similarity analyses showed the 10 loci to be independently inherited. Considerable levels of genetic differences between two subpopulations were recorded, and F(ST) was 0.034 using AMOVA. The average probability of identity (PI(ave)) was at the value of 2.6736 × 10(-15). This low value for PI(ave) nearly eliminates false identification. An illegal hunting case solved by DeerPlex is described herein. The calculated likelihood ratio (LR) illustrates the potential of the 10 red deer microsatellite markers for forensic investigations. © 2014 American Academy of Forensic Sciences.

  13. Exploratory Investigation of Early Biomarkers for Chronic Fatigue in Prostate Cancer Patients Following Radiation Therapy

    PubMed Central

    Feng, Li Rebekah; Wolff, Brian S.; Lukkahatai, Nada; Espina, Alexandra; Saligan, Leorey N.

    2016-01-01

    Background Fatigue is one of the most debilitating side effects of cancer therapy. Identifying biomarkers early during cancer therapy may help us understand the biologic underpinnings of the persistence of fatigue following therapy. Objective We aimed to identify early biomarkers of fatigue by examining correlations of levels of cytokines during external beam radiation therapy (EBRT) with persistence of fatigue one year following treatment completion in men with non-metastatic prostate cancer (NM-PC). Methods A sample of 34 men with NM-PC scheduled to receive EBRT were followed at baseline (T1), midpoint of EBRT (T2), and one year following EBRT (T3). Demographic and clinical data were obtained by chart review. The Functional Assessment of Cancer Therapy-Fatigue (FACT-F) was administered to measure fatigue levels. Plasma cytokine levels were determined at T1 and T2 using the Bio-Rad Bio-Plex Cytokine Assay Kits. Results Significant correlations were observed between levels of IL-3, IL-8, IL-9, IL-10, IL-16, IP10, IFNα2, IFNγ, and SDF1α at T2 with worsening of fatigue from T1 to T3. Conclusions Immunological changes prior to chronic fatigue development may reflect the long term response to radiation therapy-induced damage. Implications for Practice Early biomarkers for chronic fatigue related to cancer therapy will help advance our understanding of the etiology of this distressing symptom and will help nurses identify patients at risk for developing chronic fatigue after cancer treatment. This information will also aide in patient education, as well as symptom management. PMID:27105468

  14. Sub-grid drag models for horizontal cylinder arrays immersed in gas-particle multiphase flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarkar, Avik; Sun, Xin; Sundaresan, Sankaran

    2013-09-08

    Immersed cylindrical tube arrays often are used as heat exchangers in gas-particle fluidized beds. In multiphase computational fluid dynamics (CFD) simulations of large fluidized beds, explicit resolution of small cylinders is computationally infeasible. Instead, the cylinder array may be viewed as an effective porous medium in coarse-grid simulations. The cylinders' influence on the suspension as a whole, manifested as an effective drag force, and on the relative motion between gas and particles, manifested as a correction to the gas-particle drag, must be modeled via suitable sub-grid constitutive relationships. In this work, highly resolved unit-cell simulations of flow around an arraymore » of horizontal cylinders, arranged in a staggered configuration, are filtered to construct sub-grid, or `filtered', drag models, which can be implemented in coarse-grid simulations. The force on the suspension exerted by the cylinders is comprised of, as expected, a buoyancy contribution, and a kinetic component analogous to fluid drag on a single cylinder. Furthermore, the introduction of tubes also is found to enhance segregation at the scale of the cylinder size, which, in turn, leads to a reduction in the filtered gas-particle drag.« less

  15. Non-contact multi-frequency magnetic induction spectroscopy system for industrial-scale bio-impedance measurement

    NASA Astrophysics Data System (ADS)

    O'Toole, M. D.; Marsh, L. A.; Davidson, J. L.; Tan, Y. M.; Armitage, D. W.; Peyton, A. J.

    2015-03-01

    Biological tissues have a complex impedance, or bio-impedance, profile which changes with respect to frequency. This is caused by dispersion mechanisms which govern how the electromagnetic field interacts with the tissue at the cellular and molecular level. Measuring the bio-impedance spectra of a biological sample can potentially provide insight into the sample’s properties and its cellular structure. This has obvious applications in the medical, pharmaceutical and food-based industrial domains. However, measuring the bio-impedance spectra non-destructively and in a way which is practical at an industrial scale presents substantial challenges. The low conductivity of the sample requires a highly sensitive instrument, while the demands of industrial-scale operation require a fast high-throughput sensor of rugged design. In this paper, we describe a multi-frequency magnetic induction spectroscopy (MIS) system suitable for industrial-scale, non-contact, spectroscopic bio-impedance measurement over a bandwidth of 156 kHz-2.5 MHz. The system sensitivity and performance are investigated using calibration and known reference samples. It is shown to yield rapid and consistently sensitive results with good long-term stability. The system is then used to obtain conductivity spectra of a number of biological test samples, including yeast suspensions of varying concentration and a range of agricultural produce, such as apples, pears, nectarines, kiwis, potatoes, oranges and tomatoes.

  16. Developmental validation of the PowerPlex(®) Fusion System for analysis of casework and reference samples: A 24-locus multiplex for new database standards.

    PubMed

    Oostdik, Kathryn; Lenz, Kristy; Nye, Jeffrey; Schelling, Kristin; Yet, Donald; Bruski, Scott; Strong, Joshua; Buchanan, Clint; Sutton, Joel; Linner, Jessica; Frazier, Nicole; Young, Hays; Matthies, Learden; Sage, Amber; Hahn, Jeff; Wells, Regina; Williams, Natasha; Price, Monica; Koehler, Jody; Staples, Melisa; Swango, Katie L; Hill, Carolyn; Oyerly, Karen; Duke, Wendy; Katzilierakis, Lesley; Ensenberger, Martin G; Bourdeau, Jeanne M; Sprecher, Cynthia J; Krenke, Benjamin; Storts, Douglas R

    2014-09-01

    The original CODIS database based on 13 core STR loci has been overwhelmingly successful for matching suspects with evidence. Yet there remain situations that argue for inclusion of more loci and increased discrimination. The PowerPlex(®) Fusion System allows simultaneous amplification of the following loci: Amelogenin, D3S1358, D1S1656, D2S441, D10S1248, D13S317, Penta E, D16S539, D18S51, D2S1338, CSF1PO, Penta D, TH01, vWA, D21S11, D7S820, D5S818, TPOX, DYS391, D8S1179, D12S391, D19S433, FGA, and D22S1045. The comprehensive list of loci amplified by the system generates a profile compatible with databases based on either the expanded CODIS or European Standard Set (ESS) requirements. Developmental validation testing followed SWGDAM guidelines and demonstrated the quality and robustness of the PowerPlex(®) Fusion System across a number of variables. Consistent and high-quality results were compiled using data from 12 separate forensic and research laboratories. The results verify that the PowerPlex(®) Fusion System is a robust and reliable STR-typing multiplex suitable for human identification. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  17. Artificial Roughness Encoding with a Bio-inspired MEMS- based Tactile Sensor Array

    PubMed Central

    Oddo, Calogero Maria; Beccai, Lucia; Felder, Martin; Giovacchini, Francesco; Carrozza, Maria Chiara

    2009-01-01

    A compliant 2×2 tactile sensor array was developed and investigated for roughness encoding. State of the art cross shape 3D MEMS sensors were integrated with polymeric packaging providing in total 16 sensitive elements to external mechanical stimuli in an area of about 20 mm2, similarly to the SA1 innervation density in humans. Experimental analysis of the bio-inspired tactile sensor array was performed by using ridged surfaces, with spatial periods from 2.6 mm to 4.1 mm, which were indented with regulated 1N normal force and stroked at constant sliding velocity from 15 mm/s to 48 mm/s. A repeatable and expected frequency shift of the sensor outputs depending on the applied stimulus and on its scanning velocity was observed between 3.66 Hz and 18.46 Hz with an overall maximum error of 1.7%. The tactile sensor could also perform contact imaging during static stimulus indentation. The experiments demonstrated the suitability of this approach for the design of a roughness encoding tactile sensor for an artificial fingerpad. PMID:22412304

  18. Effect of inorganic or organic selenium supplementation on reproductive performance and tissue trace mineral concentrations in gravid first-parity gilts, fetuses, and nursing piglets.

    PubMed

    Ma, Y L; Lindemann, M D; Pierce, J L; Unrine, J M; Cromwell, G L

    2014-12-01

    The objective of this experiment was to evaluate 2 supplemental forms of Se on reproductive performance and tissue trace mineral concentration in fetus and first-parity gilts during pregnancy and their progeny. Crossbred gilts (n=100) were selected at 183±2.7 d and 137±10 kg BW and fed a common diet. After 1 mo, 8 gilts were sacrificed to establish baseline liver Se concentration and the remaining 92 gilts allotted to receive Se (0.3 mg/kg diet) as inorganic Se (Na2SeO3) or a Se supplement that contains organoselenium compounds (Sel-Plex; Alltech Inc., Nicholasville, KY). At 267±5.7 d (171±11 kg), gilts were estrus-synchronized and bred. Gilts were then slaughtered at defined time points throughout gestation (d 0, 43, 58, 73, 91, 101, or 108 of gestation; n=6 to 12 gilts/time point). A week before the expected farrowing day, 10 pregnant gilts (5 from each treatment) were moved to farrowing crates and monitored. Two pigs from each litter were randomly selected and euthanized at d 0 (within 2 h after birth; nursing deprived), 7, 14, and 21 from each litter. During the gestation phase, maternal liver, and fetal body and liver were collected for determination of trace mineral concentration by inductively coupled plasma mass spectrometry. Total number of fetus, crown-rump length, and corpora lutea of gilts were recorded as well. During the lactation phase, pigs (without liver and gastrointestinal tract) and associated liver were analyzed for Se concentration. The results demonstrated that the source of Se generally did not affect the maternal reproductive traits and fetal characteristics. Also, the source of Se supplemented to the maternal diet did not, in general, affect Cu, Fe, Mn, or Zn concentrations in the tissues evaluated other than the observation of a greater maternal liver Mn content (P<0.01) in gilts fed Sel-Plex and a greater amount of Fe accumulated in the entire litter (P<0.01) in gilts fed Sel-Plex. However, with regard to Se concentrations, Se in fetal body, fetal liver, and maternal liver were greater (P<0.01) when Sel-Plex was fed. Postnatal pigs from gilts fed Sel-Plex had greater (P<0.05) Se retention in body and liver with similar growth performance during the 21-d period. The results demonstrate Se form differences wherein Sel-Plex is associated with greater Se accumulation in both maternal and fetal tissues.

  19. Two-dimensional patterning of colloidal crystals by means of lateral autocloning in edge-patterned cells

    NASA Astrophysics Data System (ADS)

    Emoto, Akira; Kamei, Tadayoshi; Shioda, Tatsutoshi; Kawatsuki, Nobuhiro; Ono, Hiroshi

    2009-06-01

    We report the experimental results of two-dimensional patterning of colloidal crystals using edge-patterned cells. Solvent evaporation of a colloidal suspension from the edge of the cell induces self-organized crystallization of spherical colloidal particles. From a reservoir of colloidal suspension in the cell, different colloidal suspensions are injected repetitively. An edge-patterned substrate is introduced into the cell as an upper substrate. As a result, different colloidal crystals are alternately stacked in the lateral direction according to the edge pattern. The characteristics of cloning formation are specifically showed including deformations from the original pattern. This two-dimensional patterning of three-dimensional colloidal crystals by means of lateral autocloning is promising for the development of photonic crystal arrays for use in optic and photonic devices.

  20. A micro-sized bio-solar cell for self-sustaining power generation.

    PubMed

    Lee, Hankeun; Choi, Seokheun

    2015-01-21

    Self-sustainable energy sources are essential for a wide array of wireless applications deployed in remote field locations. Due to their self-assembling and self-repairing properties, "biological solar (bio-solar) cells" are recently gaining attention for those applications. The bio-solar cell can continuously generate electricity from microbial photosynthetic and respiratory activities under day-night cycles. Despite the vast potential and promise of bio-solar cells, they, however, have not yet successfully been translated into commercial applications, as they possess persistent performance limitations and scale-up bottlenecks. Here, we report an entirely self-sustainable and scalable microliter-sized bio-solar cell with significant power enhancement by maximizing solar energy capture, bacterial attachment, and air bubble volume in well-controlled microchambers. The bio-solar cell has a ~300 μL single chamber defined by laser-machined poly(methyl methacrylate) (PMMA) substrates and it uses an air cathode to allow freely available oxygen to act as an electron acceptor. We generated a maximum power density of 0.9 mW m(-2) through photosynthetic reactions of cyanobacteria, Synechocystis sp. PCC 6803, which is the highest power density among all micro-sized bio-solar cells.

  1. Ergodicity, configurational entropy and free energy in pigment solutions and plant photosystems: influence of excited state lifetime.

    PubMed

    Jennings, Robert C; Zucchelli, Giuseppe

    2014-01-01

    We examine ergodicity and configurational entropy for a dilute pigment solution and for a suspension of plant photosystem particles in which both ground and excited state pigments are present. It is concluded that the pigment solution, due to the extreme brevity of the excited state lifetime, is non-ergodic and the configurational entropy approaches zero. Conversely, due to the rapid energy transfer among pigments, each photosystem is ergodic and the configurational entropy is positive. This decreases the free energy of the single photosystem pigment array by a small amount. On the other hand, the suspension of photosystems is non-ergodic and the configurational entropy approaches zero. The overall configurational entropy which, in principle, includes contributions from both the single excited photosystems and the suspension which contains excited photosystems, also approaches zero. Thus the configurational entropy upon photon absorption by either a pigment solution or a suspension of photosystem particles is approximately zero. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Biotactile Sensors: Self-Powered Electronic Skin with Biotactile Selectivity (Adv. Mater. 18/2016).

    PubMed

    Hu, Kesong; Xiong, Rui; Guo, Hengyu; Ma, Ruilong; Zhang, Shuaidi; Wang, Zhong Lin; Tsukruk, Vladimir V

    2016-05-01

    On page 3549, V. V. Tsukruk and co-workers develop self-powered ultrathin flexible films for bio-tactile detection. Graphene oxide materials are engineered for robust self-powered tactile sensing applications harnessing their electrochemical reactivity. The simple quadruple electronic skin sensor can recognize nine spatial bio-tactile positions with high sensitivity and selectivity-an approach that can be expanded towards large-area flexible skin arrays. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Comparison of FilmArray and Quantitative Real-Time Reverse Transcriptase PCR for Detection of Zaire Ebolavirus from Contrived and Clinical Specimens

    PubMed Central

    Southern, Timothy R.; Racsa, Lori D.; Albariño, César G.; Fey, Paul D.; Hinrichs, Steven H.; Murphy, Caitlin N.; Herrera, Vicki L.; Sambol, Anthony R.; Hill, Charles E.; Ryan, Emily L.; Kraft, Colleen S.; Campbell, Shelley; Sealy, Tara K.; Schuh, Amy; Ritchie, James C.; Lyon, G. Marshall; Mehta, Aneesh K.; Varkey, Jay B.; Ribner, Bruce S.; Brantly, Kent P.; Ströher, Ute; Iwen, Peter C.

    2015-01-01

    Rapid, reliable, and easy-to-use diagnostic assays for detection of Zaire ebolavirus (ZEBOV) are urgently needed. The goal of this study was to examine the agreement among emergency use authorization (EUA) tests for the detection of ZEBOV nucleic acids, including the BioFire FilmArray BioThreat (BT) panel, the FilmArray BT-E panel, and the NP2 and VP40 quantitative real-time reverse transcriptase (qRT) PCR assays from the Centers for Disease Control and Prevention (CDC). Specimens used in this study included whole blood spiked with inactivated ZEBOV at known titers and whole-blood, plasma, and urine clinical specimens collected from persons diagnosed with Ebola virus disease (EVD). The agreement for FilmArray and qRT-PCR results using contrived whole-blood specimens was 100% (6/6 specimens) for each ZEBOV dilution from 4 × 107 to 4 × 102 50% tissue culture infective dose (TCID50)/ml, as well as the no-virus negative-control sample. The limit of detection for FilmArray and qRT-PCR assays with inactivated ZEBOV, based on duplicate positive results, was determined to be 4 × 102 TCID50/ml. Rates of agreement between FilmArray and qRT-PCR results for clinical specimens from patients with EVD were 85% (23/27 specimens) for whole-blood specimens, 90% (18/20 specimens) for whole-blood specimens tested by FilmArray testing and matched plasma specimens tested by qRT-PCR testing, and 85% (11/13 specimens) for urine specimens. Among 60 specimens, eight discordant results were noted, with ZEBOV nucleic acids being detected only by FilmArray testing in four specimens and only by qRT-PCR testing in the remaining four specimens. These findings demonstrate that the rapid and easy-to-use FilmArray panels are effective tests for evaluating patients with EVD. PMID:26157148

  4. The influence of gravity on the distribution of the deposit formed onto a substrate by sessile, hanging, and sandwiched hanging drop evaporation.

    PubMed

    Sandu, Ion; Fleaca, Claudiu Teodor

    2011-06-15

    The focus of the present article is the study of the influence of gravity on the particle deposition profiles on a solid substrate during the evaporation of sessile, hanging and sandwiched hanging drops of colloidal particle suspensions. For concentrations of nanoparticles in the colloidal solutions in the range 0.0001-1 wt.%, highly diluted suspensions will preferentially form rings while concentrated suspensions will preferentially form spots in both sessile and hanging drop evaporation. For intermediary concentrations, the particle deposition profiles will depend on the nanoparticle aggregation dynamics in the suspension during the evaporation process, gravity and on the detailed evaporation geometry. The evaporation of a drop of toluene/carbon nanoparticle suspension hanging from a pendant water drop will leave on the substrate a circular spot with no visible external ring. By contrast, a clear external ring is formed on the substrate by the sessile evaporation of a similar drop of suspension sandwiched between a water drop and the substrate. From the application viewpoint, these processes can be used to create preferential electrical conductive carbon networks and contacts for arrays of self-assembled nanostructures fabricated on solid substrates as well as on flexible polymeric substrates. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Rapid fabrication of microneedles using magnetorheological drawing lithography.

    PubMed

    Chen, Zhipeng; Ren, Lei; Li, Jiyu; Yao, Lebin; Chen, Yan; Liu, Bin; Jiang, Lelun

    2018-01-01

    Microneedles are micron-sized needles that are widely applied in biomedical fields owing to their painless, minimally invasive, and convenient operation. However, most microneedle fabrication approaches are costly, time consuming, involve multiple steps, and require expensive equipment. In this study, we present a novel magnetorheological drawing lithography (MRDL) method to efficiently fabricate microneedle, bio-inspired microneedle, and molding-free microneedle array. With the assistance of an external magnetic field, the 3D structure of a microneedle can be directly drawn from a droplet of curable magnetorheological fluid. The formation process of a microneedle consists of two key stages, elasto-capillary self-thinning and magneto-capillary self-shrinking, which greatly affect the microneedle height and tip radius. Penetration and fracture tests demonstrated that the microneedle had sufficient strength and toughness for skin penetration. Microneedle arrays and a bio-inspired microneedle were also fabricated, which further demonstrated the versatility and flexibility of the MRDL method. Microneedles have been widely applied in biomedical fields owing to their painless, minimally invasive, and convenient operation. However, most microneedle fabrication approaches are costly, time consuming, involve multiple steps, and require expensive equipment. Furthermore, most researchers have focused on the biomedical applications of microneedles but have given little attention to the optimization of the fabrication process. This research presents a novel magnetorheological drawing lithography (MRDL) method to fabricate microneedle, bio-inspired microneedle, and molding-free microneedle array. In this proposed technique, a droplet of curable magnetorheological fluid (CMRF) is drawn directly from almost any substrate to produce a 3D microneedle under an external magnetic field. This method not only inherits the advantages of thermal drawing approach without the need for a mask and light irradiation but also eliminates the requirement for drawing temperature adjustment. The MRDL method is extremely simple and can even produce the complex and multiscale structure of bio-inspired microneedle. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  6. One-step simultaneous detection of Ureaplasma parvum and genotypes SV1, SV3 and SV6 from clinical samples using PlexPCR technology.

    PubMed

    Payne, M S; Furfaro, L L; Tucker, R; Tan, L Y; Mokany, E

    2017-08-01

    Ureaplasma spp. are associated with preterm birth. In recent times, it has become apparent that Ureaplasma parvum, but not Ureaplasma urealyticum, is of most relevance. We recently demonstrated this in Australian pregnant women and using high-resolution melt (HRM) PCR, further showed that U. parvum genotype SV6 was of particular significance. However, our assay was unable to identify multiple genotypes in the same sample, required a separate species-level qPCR for low titre samples and was not ideal for diagnostic laboratories due to the nature of HRM PCR result interpretation. Consequently, our current study developed a novel, one-step PlexPCR assay capable of detecting U. parvum and genotypes SV1, SV3 and SV6 in a single reaction directly from clinical samples. We then validated this using vaginal swab DNA from our Australian cohort of pregnant women. The PlexPCR was highly sensitive, detecting all targets to between 0.4 × 10 -5  ng DNA (SV3) and 0.4 × 10 -6  ng DNA (U. parvum, SV1 and SV6). Compared to our HRM PCR, the PlexPCR defined genotype distribution in all seven cases previously reported as 'mixed', and detected another eight cases where multiple genotypes (two) were present in samples previously reported as single genotypes using HRM PCR. Ureaplasma spp. have been associated with prematurity for decades, however, only a minority of studies have examined this beyond the genus level. In those that have, Ureaplasma parvum has been strongly associated with preterm birth. We recently demonstrated this in Australian women and further showed that U. parvum genotype SV6 was of particular significance. Our PlexPCR assay allows rapid detection and concurrent genotyping of U. parvum in clinical samples and may be of particular interest to obstetricians, particularly those caring for women at a high risk of preterm birth, and any other disease phenotypes where U. parvum is of interest. © 2017 The Authors. Letters in Applied Microbiology published by John Wiley & Sons Ltd on behalf of The Society for Applied Microbiology.

  7. Improved amplification results following episodes of failure to amplify at the Amelogenin Locus using PowerPlex® ESI 16 Fast System.

    PubMed

    Berlyne, Sigal; Oz, Carla; Einot, Naftaly; Avraham, Shlomit; Ram, Tanya; Goldberg, Miri D; Gafny, Ron

    2017-07-01

    In 2012 the Israel Police DNA Casework laboratory adopted the 16 STR PowerPlex ® ESI kit for routine use. The Promega Company updated this kit and developed the PowerPlex ® ESI 16 Fast System in which all autosomal primer pairs remained identical to the original set, except at the amelogenin site. The master mix was improved and optimized which allowed for direct, faster and more robust amplification. Prior to implementing the PowerPlex ® ESI 16 Fast System in our lab, we conducted a preliminary assay where 213 casework samples were amplified using the new kit. These samples had previously been extracted by one of two extraction kits employed by our lab. (the PrepFiler ExpressTM and PrepFiler BTATM Forensic DNA Extraction Kits). The amplification results from these samples were compared to samples amplified using the original PowerPlex ® ESI 16 kit. Multiple incidents of failure to amplify at the amelogenin locus were noted using the new system with the recommended protocol at a rate of 13% (28 of 213 samples). Experiments were performed to understand whether these amplification failures could be a result of primer binding site mutations, extraction method reagents and/or inhibitors. The conclusions reached following these experiments, in conjunction with consultation with the manufacturer, led to the trial of a modified amplification protocol where the suggested annealing temperature was reduced by 2 degrees. To evaluate the efficiency of this altered protocol, a comparison study was undertaken where 88 additional casework samples were chosen and amplified using both the modified 58°C and the recommended 60°C annealing temperatures. We concluded that the most effective method in our laboratory for achieving a consistent and balanced amplification at the amelogenin locus was to reduce the annealing temperature from the manufacturer's recommended 60°C to 58°C. This modification resulted in a reduction of the failure to amplify at the amelogenin locus from 13% (28/213) to 1.1% (1/88) without any observed changes to the autosomal STR amplification results. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. The role of bio-physical cohesive substrates on sediment winnowing and bedform development

    NASA Astrophysics Data System (ADS)

    Ye, Leiping; Parsons, Daniel; Manning, Andrew

    2017-04-01

    Existing sediment transport and bedform size predictions for natural open-channel flows in many environments are seriously impeded by a lack of process-based knowledge concerning the dynamics of complex bed sediment mixtures comprising cohesionless sand and biologically-active cohesive muds. A series of flume experiments (14 experimental runs) with different substrate mixtures of sand-clay-EPS (Extracellular Polymeric Substance) are combined with a detailed estuarine field survey (Dee estuary, NW England) to investigate the development of bedform morphologies and characteristics of suspended sediment over bio-physical cohesive substrates. The experimental results indicate that winnowing and sediment sorting can occur pervasively in bio-physical cohesive sediment - flow systems. Importantly however, the evolution of the bed and bedform dynamics, and hence turbulence production, is significantly reduced as bed substrate cohesivity increases. The estuarine subtidal zone survey also revealed that the bio-physical cohesion provided by both the clay and microorganism fractions in the bed plays a significant role in controlling the interactions between bed substrate and sediment suspension, deposition and bedform generation. The work will be presented here concludes by outlining the need to extend and revisit the effects of cohesivity in morphodynamic systems and the sets of parameters presently used in numerical modelling, particularly in the context of the impact of climate change on estuarine and coastal systems.

  9. Automated preparation method for colloidal crystal arrays of monodisperse and binary colloid mixtures by contact printing with a pintool plotter.

    PubMed

    Burkert, Klaus; Neumann, Thomas; Wang, Jianjun; Jonas, Ulrich; Knoll, Wolfgang; Ottleben, Holger

    2007-03-13

    Photonic crystals and photonic band gap materials with periodic variation of the dielectric constant in the submicrometer range exhibit unique optical properties such as opalescence, optical stop bands, and photonic band gaps. As such, they represent attractive materials for the active elements in sensor arrays. Colloidal crystals, which are 3D gratings leading to Bragg diffraction, are one potential precursor of such optical materials. They have gained particular interest in many technological areas as a result of their specific properties and ease of fabrication. Although basic techniques for the preparation of regular patterns of colloidal crystals on structured substrates by self-assembly of mesoscopic particles are known, the efficient fabrication of colloidal crystal arrays by simple contact printing has not yet been reported. In this article, we present a spotting technique used to produce a microarray comprising up to 9600 single addressable sensor fields of colloidal crystal structures with dimensions down to 100 mum on a microfabricated substrate in different formats. Both monodisperse colloidal crystals and binary colloidal crystal systems were prepared by contact printing of polystyrene particles in aqueous suspension. The array morphology was characterized by optical light microscopy and scanning electron microscopy, which revealed regularly ordered crystalline structures for both systems. In the case of binary crystals, the influence of the concentration ratio of the large and small particles in the printing suspension on the obtained crystal structure was investigated. The optical properties of the colloidal crystal arrays were characterized by reflection spectroscopy. To examine the stop bands of the colloidal crystal arrays in a high-throughput fashion, an optical setup based on a CCD camera was realized that allowed the simultaneous readout of all of the reflection spectra of several thousand sensor fields per array in parallel. In agreement with Bragg's relation, the investigated arrays exhibited strong opalescence and stop bands in the expected wavelength range, confirming the successful formation of highly ordered colloidal crystals. Furthermore, a narrow distribution of wavelength-dependent stop bands across the sensor array was achieved, demonstrating the capability of producing highly reproducible crystal spots by the contact printing method with a pintool plotter.

  10. Direct transfer of subwavelength plasmonic nanostructures on bioactive silk films.

    PubMed

    Lin, Dianmin; Tao, Hu; Trevino, Jacob; Mondia, Jessica P; Kaplan, David L; Omenetto, Fiorenzo G; Dal Negro, Luca

    2012-11-27

    By a reusable transfer fabrication technique, we demonstrate high-fidelity fabrication of metal nanoparticles, optical nanoantennas, and nanohole arrays directly on a functional silk biopolymer. The ability to reproducibly pattern silk biopolymers with arbitrarily complex plasmonic arrays is of importance for a variety of applications in optical biosensing, tissue engineering, cell biology, and the development of novel bio-optoelectronic medical devices. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Transparent arrays of silver nanowire rings driven by evaporation of sessile droplets

    NASA Astrophysics Data System (ADS)

    Wang, Xiaofeng; Kang, Giho; Seong, Baekhoon; Chae, Illkyeong; Teguh Yudistira, Hadi; Lee, Hyungdong; Kim, Hyunggun; Byun, Doyoung

    2017-11-01

    A coffee-ring pattern can be yielded on the three-phase contact line following evaporation of sessile droplets with suspended insoluble solutes, such as particles, DNA molecules, and mammalian cells. The formation of such coffee-ring, together with their suppression has been applied in printing and coating technologies. We present here an experimental study on the assembly of silver nanowires inside an evaporating droplet of a colloidal suspension. The effects of nanowire length and concentration on coffee-ring formation of the colloidal suspension were investigated. Several sizes of NWs with an aspect ratio between 50 and 1000 were systematically investigated to fabricate coffee-ring patterns. Larger droplets containing shorter nanowires formed clearer ring deposits after evaporation. An order-to-disorder transition of the nanowires’ alignment was found inside the rings. A printing technique with the evaporation process enabled fabrication of arrays of silver nanowire rings. We could manipulate the patterns silver nanowire rings, which might be applied to the transparent and flexible electrode.

  12. Viscosity of dilute suspensions of rigid bead arrays at low shear: accounting for the variation in hydrodynamic stress over the bead surfaces.

    PubMed

    Allison, Stuart A; Pei, Hongxia

    2009-06-11

    In this work, we examine the viscosity of a dilute suspension of irregularly shaped particles at low shear. A particle is modeled as a rigid array of nonoverlapping beads of variable size and geometry. Starting from a boundary element formalism, approximate account is taken of the variation in hydrodynamic stress over the surface of the individual beads. For a touching dimer of two identical beads, the predicted viscosity is lower than the exact value by 5.2%. The methodology is then applied to several other model systems including tetramers of variable conformation and linear strings of touching beads. An analysis is also carried out of the viscosity and translational diffusion of several dilute amino acids and diglycine in water. It is concluded that continuum hydrodynamic modeling with stick boundary conditions is unable to account for the experimental viscosity and diffusion data simultaneously. A model intermediate between "stick" and "slip" could possibly reconcile theory and experiment.

  13. Development of a General-Purpose Analysis System Based on a Programmable Fluid Processor Final Report CRADA No. TC-2027-01

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McConaghy, C. F.; Gascoyne, P. R.

    The purpose ofthis project was to develop a general-purpose analysis system based on a programmable fluid processor (PFP). The PFP is an array of electrodes surrounded by fluid reservoirs and injectors. Injected droplets of various reagents are manjpulated and combined on the array by Dielectrophoretic (DEP) forces. The goal was to create a small handheld device that could accomplish the tasks currently undertaken by much larger, time consuming, manual manipulation in the lab. The entire effo1t was funded by DARPA under the Bio-Flips program. MD Anderson Cancer Center was the PI for the DARPA effort. The Bio-Flips program was amore » 3- year program that ran from September 2000 to September 2003. The CRADA was somewhat behind the Bi-Flips program running from June 2001 to June 2004 with a no cost extension to September 2004.« less

  14. Enhancing pathogen identification in patients with meningitis and a negative Gram stain using the BioFire FilmArray(®) Meningitis/Encephalitis panel.

    PubMed

    Wootton, Susan H; Aguilera, Elizabeth; Salazar, Lucrecia; Hemmert, Andrew C; Hasbun, Rodrigo

    2016-04-21

    Meningitis with a negative cerebrospinal (CSF) Gram stain represents a diagnostic and therapeutic challenge. The purpose of our study was to evaluate the performance of the BioFire FilmArray(®) Meningitis/Encephalitis (FA ME) panel in patients presenting with community-acquired meningitis with a negative Gram stain. CSF from 48 patients with community-acquired meningitis with a negative Gram stain admitted to four hospitals in Houston, TX underwent additional testing by the FA ME. FA ME results were compared to results obtained as part of routine evaluation. The panel detected pathogens not previously identified in 11 (22.9 %) of 48, but did not detect pathogens identified by standard technique (West Nile virus, Histoplasma) in 5 (15.2 %) patients. Rapid testing for the most common pathogens causing meningitis will aid in the diagnosis and treatment of patients with meningitis.

  15. Red blood cell (RBC) suspensions in confined microflows: Pressure-flow relationship.

    PubMed

    Stauber, Hagit; Waisman, Dan; Korin, Netanel; Sznitman, Josué

    2017-10-01

    Microfluidic-based assays have become increasingly popular to explore microcirculation in vitro. In these experiments, blood is resuspended to a desired haematocrit level in a buffer solution, where frequent choices for preparing RBC suspensions comprise notably Dextran and physiological buffer. Yet, the rational for selecting one buffer versus another is often ill-defined and lacks detailed quantification, including ensuing changes in RBC flow characteristics. Here, we revisit RBC suspensions in microflows and attempt to quantify systematically some of the differences emanating between buffers. We measure bulk flow rate (Q) of RBC suspensions, using PBS- and Dextran-40, as a function of the applied pressure drop (ΔP) for two hematocrits (∼0% and 23%). Two distinct microfluidic designs of varying dimensions are employed: a straight channel larger than and a network array similar to the size of individual RBCs. Using the resulting pressure-flow curves, we extract the equivalent hydrodynamic resistances and estimate the relative viscosities. These efforts are a first step in rigorously quantifying the influence of the 'background' buffer on RBC flows within microfluidic devices and thereby underline the importance of purposefully selecting buffer suspensions for microfluidic in vitro assays. Copyright © 2017. Published by Elsevier Ltd.

  16. Analysis of the SNPforID 52-plex markers in four Native American populations from Venezuela.

    PubMed

    Ruiz, Y; Chiurillo, M A; Borjas, L; Phillips, C; Lareu, M V; Carracedo, Á

    2012-09-01

    The SNPforID 52-plex single nucleotide polymorphisms (SNPs) were analyzed in four native Venezuelan populations: Bari, Pemon, Panare and Warao. None of the population-locus combinations showed significant departure from Hardy-Weinberg equilibrium. Calculation of forensic and statistical parameters showed lower values of genetic diversity in comparison with African and European populations, as well as other, admixed populations of neighboring regions of Caribbean, Central and South America. Significant levels of divergence were observed between the four Native Venezuelan populations as well as with other previously studied populations. Analysis of the 52-plex SNP loci with Structure provided an optimum number of population clusters of three, corresponding to Africans, Europeans and Native Americans. Analysis of admixed populations indicated a range of membership proportions for ancestral populations consisting of Native American, African and European components. The genetic differences observed in the Native American groups suggested by the 52 SNPs typed in our study are in agreement with current knowledge of the demographic history of the Americas. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Hi-Plex for Simple, Accurate, and Cost-Effective Amplicon-based Targeted DNA Sequencing.

    PubMed

    Pope, Bernard J; Hammet, Fleur; Nguyen-Dumont, Tu; Park, Daniel J

    2018-01-01

    Hi-Plex is a suite of methods to enable simple, accurate, and cost-effective highly multiplex PCR-based targeted sequencing (Nguyen-Dumont et al., Biotechniques 58:33-36, 2015). At its core is the principle of using gene-specific primers (GSPs) to "seed" (or target) the reaction and universal primers to "drive" the majority of the reaction. In this manner, effects on amplification efficiencies across the target amplicons can, to a large extent, be restricted to early seeding cycles. Product sizes are defined within a relatively narrow range to enable high-specificity size selection, replication uniformity across target sites (including in the context of fragmented input DNA such as that derived from fixed tumor specimens (Nguyen-Dumont et al., Biotechniques 55:69-74, 2013; Nguyen-Dumont et al., Anal Biochem 470:48-51, 2015), and application of high-specificity genetic variant calling algorithms (Pope et al., Source Code Biol Med 9:3, 2014; Park et al., BMC Bioinformatics 17:165, 2016). Hi-Plex offers a streamlined workflow that is suitable for testing large numbers of specimens without the need for automation.

  18. Retrograde Semaphorin-Plexin Signaling Drives Homeostatic Synaptic Plasticity

    PubMed Central

    Orr, Brian O.; Fetter, Richard D.; Davis, Graeme W.

    2017-01-01

    Homeostatic signaling systems ensure stable, yet flexible neural activity and animal behavior1–4. Defining the underlying molecular mechanisms of neuronal homeostatic signaling will be essential in order to establish clear connections to the causes and progression of neurological disease. Presynaptic homeostatic plasticity (PHP) is a conserved form of neuronal homeostatic signaling, observed in organisms ranging from Drosophila to human1,5. Here, we demonstrate that Semaphorin2b (Sema2b) is target-derived signal that acts upon presynaptic PlexinB (PlexB) receptors to mediate the retrograde, homeostatic control of presynaptic neurotransmitter release at the Drosophila neuromuscular junction. Sema2b-PlexB signaling regulates the expression of PHP via the cytoplasmic protein Mical and the oxoreductase-dependent control of presynaptic actin6,7. During neural development, Semaphorin-Plexin signaling instructs axon guidance and neuronal morphogenesis8–10. Yet, Semaphorins and Plexins are also expressed in the adult brain11–16. Here we demonstrate that Semaphorin-Plexin signaling controls presynaptic neurotransmitter release. We propose that Sema2b-PlexB signaling is an essential platform for the stabilization of synaptic transmission throughout life. PMID:28953869

  19. Low-template methods yield limited extra information for PowerPlex® Fusion 6C profiling.

    PubMed

    Duijs, Francisca; van de Merwe, Linda; Sijen, Titia; Benschop, Corina C G

    2018-06-01

    Advances in autosomal DNA profiling systems enable analyzing increased numbers of short tandem repeat (STR) loci in one reaction. Increasing the number of STR loci increases the amount of information that may be obtained from a (crime scene) sample. In this study, we examined whether even more allelic information can be obtained by applying low-template methods. To this aim, the performance of the PowerPlex® Fusion 6C STR typing system was assessed when increasing the number of PCR cycles or enhancing the capillary electrophoresis (CE) injection settings. Results show that applying these low-template methods yields limited extra information and comes at cost of more background noise. In addition, the gain in detection of alleles was much smaller when compared to the gain when applying low-template methods to the 15-loci AmpFLSTR® NGM™ system. Consequently, the PowerPlex® Fusion 6C STR typing system was implemented using standard settings only; low-template methods were not implemented for our routine forensic casework. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. bioWidgets: data interaction components for genomics.

    PubMed

    Fischer, S; Crabtree, J; Brunk, B; Gibson, M; Overton, G C

    1999-10-01

    The presentation of genomics data in a perspicuous visual format is critical for its rapid interpretation and validation. Relatively few public database developers have the resources to implement sophisticated front-end user interfaces themselves. Accordingly, these developers would benefit from a reusable toolkit of user interface and data visualization components. We have designed the bioWidget toolkit as a set of JavaBean components. It includes a wide array of user interface components and defines an architecture for assembling applications. The toolkit is founded on established software engineering design patterns and principles, including componentry, Model-View-Controller, factored models and schema neutrality. As a proof of concept, we have used the bioWidget toolkit to create three extendible applications: AnnotView, BlastView and AlignView.

  1. A Rapid and Inexpensive PCR-Based STR Genotyping Method for Identifying Forensic Specimens

    DTIC Science & Technology

    2006-06-01

    this report) 20. Security Classif. (of this page) 21 . No. of Pages 22. Price Unclassified Unclassified 18 Form DOT F 1700.7 (8-72) Reproduction of...Promega PowerPlex 2.1 system (7) except that the buffer was 1x Amplitaq gold reaction buffer, 0.1% TritonX-100, and 0.2mM each dNTP in a 25µl final...electrophoresis were done using the PowerPlex 16 System (Promega Corp.; Madison, WI). rEsulTs ANd dIsCussION The goal of this study was to develop a simple DNA

  2. Preparation of peanut butter suspension for determination of peanuts using enzyme-linked immunoassay kits.

    PubMed

    Trucksess, Mary W; Brewer, Vickery A; Williams, Kristina M; Westphal, Carmen D; Heeres, James T

    2004-01-01

    Peanuts are one of the 8 most common allergenic foods and a large proportion of peanut-allergic individuals have severe reactions, some to minimal exposure. Specific protein constituents in the peanuts are the cause of the allergic reactions in sensitized individuals who ingest the peanuts. To avoid accidental ingestion of peanut-contaminated food, methods of analysis for the determination of the allergenic proteins in foods are important tools. Such methods could help identify foods inadvertently contaminated with peanuts, thereby reducing the incidence of allergic reactions to peanuts. Commercial immunoassay kits are available but need study for method performance, which requires reference materials for within- and between-laboratory validations. In this study, National Institute of Standards and Technology Standard Reference Material 2387 peanut butter was used. A polytron homogenizer was used to prepare a homogenous aqueous Peanut Butter suspension for the evaluation of method performance of some commercially available immunoassay kits such as Veratox for Peanut Allergen Test (Neogen Corp.), Ridascreen Peanut (R-Biopharm GmbH), and Bio-Kit Peanut Protein Assay Kit (Tepnel). Each gram of the aqueous peanut butter suspension contained 20 mg carboxymethylcellulose sodium salt, 643 microg peanut, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. The suspension was homogenous, stable, reproducible, and applicable for adding to ice cream, cookies, breakfast cereals, and chocolate for recovery studies at spike levels ranging from 12 to 90 microg/g.

  3. Harmonic decomposition of magneto-optical signal from suspensions of superparamagnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Patterson, Cody; Syed, Maarij; Takemura, Yasushi

    2018-04-01

    Magnetic nanoparticles (MNPs) are widely used in biomedical applications. Characterizing dilute suspensions of superparamagnetic iron oxide nanoparticles (SPIONs) in bio-relevant media is particularly valuable for magnetic particle imaging, hyperthermia, drug delivery, etc. Here, we study dilute aqueous suspensions of single-domain magnetite nanoparticles using an AC Faraday rotation (FR) setup. The setup uses an oscillating magnetic field (800 Hz) which generates a multi-harmonic response. Each harmonic is collected and analyzed using the Fourier components of the theoretical signal determined by a Langevin-like magnetization. With this procedure, we determine the average magnetic moment per particle μ , particle number density n, and Verdet constant of the sample. The fitted values of μ and n are shown to be consistent across each harmonic. Additionally, we present the results of these parameters as n is varied. The large values of μ reveal the possibility of clustering as reported in other literature. This suggests that μ is representative of the average magnetic moment per cluster of nanoparticles. Multiple factors, including the external magnetic field, surfactant degradation, and laser absorption, can contribute to dynamic and long-term aggregation leading to FR signals that represent space- and time-averaged sample parameters. Using this powerful analysis procedure, future studies are aimed at determining the clustering mechanisms in this AC system and characterizing SPION suspensions at different frequencies and viscosities.

  4. Electric-field-induced dielectrophoresis and heterogeneous aggregation in dilute suspensions of positively polarizable particles

    NASA Astrophysics Data System (ADS)

    Acrivos, Andreas; Qiu, Zhiyong; Markarian, Nikolai; Khusid, Boris

    2002-11-01

    We specified the conditions under which a dilute suspension of positively polarizable particles would undergo a heterogeneous aggregation in high-gradient strong AC fields and then examined experimentally and theoretically its kinetics [1]. Experiments were conducted on flowing dilute suspensions of heavy aluminum oxide spheres subjected to a high-gradient AC field (several kV/mm) such that the dielectrophoretic force acting on the particles was arranged in the plane perpendicular to the streamlines of the main flow. To reduce the gravitational settling of the particles, the electric chamber was kept slowly rotating around a horizontal axis. Following the application of a field, the particles were found to move towards both the high-voltage and grounded electrodes and to form arrays of "bristles" along their edges. The process was modeled by computing the motion of a single particle under the action of dielectrophoretic, viscous, and gravitational forces for negligibly small particle Reynolds numbers. The particle polarization required for the calculation of the dielectrophoretic force was measured in low-strength fields (several V/mm). The theoretical predictions for the kinetics of the particle accumulation on the electrodes were found to be in a reasonable agreement with experiment, although the interparticle interactions governed the formation of arrays of bristles. These bristles were formed in a two-step mechanism, which arose from the interplay of the dielectrophoretic force that confined the particles near the electrode edge and the dipolar interactions of nearby particles. The results of our studies provide the basic characteristics needed for the design and optimization of electro-hydrodynamic apparatuses. The work was supported by a NASA grant. The suspension characterization was conducted at the NJIT W.M. Keck Laboratory. 1. Z. Qiu, N. Markarian, B. Khusid, A. Acrivos, J. Apple. Phys., 92(5), 2002.

  5. Tunable TiO2 Nanotube Arrays for Flexible Bio-Sensitized Solar Cells

    DTIC Science & Technology

    2012-08-01

    microid extender followed by a colloidal silica /wetted imperial cloth. The foil was then cut into 1- × 2-cm samples. Then, the substrates were...17. Lei, B.; Liao, J.; Wang, R. J.; Su, C.; Kuang, D. Ordered Crystalline Ti02 Nanotube Arrays on Transparent FTO Glass for Efficient Dye...combined with a transparent , Indium Tin Dioxide coated PET film are attractive candidates for efficient, flexible DSSC’s. Flexible solar cells offer

  6. Comparison of printed glycan array, suspension array and ELISA in the detection of human anti-glycan antibodies.

    PubMed

    Pochechueva, Tatiana; Jacob, Francis; Goldstein, Darlene R; Huflejt, Margaret E; Chinarev, Alexander; Caduff, Rosemarie; Fink, Daniel; Hacker, Neville; Bovin, Nicolai V; Heinzelmann-Schwarz, Viola

    2011-12-01

    Anti-glycan antibodies represent a vast and yet insufficiently investigated subpopulation of naturally occurring and adaptive antibodies in humans. Recently, a variety of glycan-based microarrays emerged, allowing high-throughput profiling of a large repertoire of antibodies. As there are no direct approaches for comparison and evaluation of multi-glycan assays we compared three glycan-based immunoassays, namely printed glycan array (PGA), fluorescent microsphere-based suspension array (SA) and ELISA for their efficacy and selectivity in profiling anti-glycan antibodies in a cohort of 48 patients with and without ovarian cancer. The ABO blood group glycan antigens were selected as well recognized ligands for sensitivity and specificity assessments. As another ligand we selected P(1), a member of the P blood group system recently identified by PGA as a potential ovarian cancer biomarker. All three glyco-immunoassays reflected the known ABO blood groups with high performance. In contrast, anti-P(1) antibody binding profiles displayed much lower concordance. Whilst anti-P(1) antibody levels between benign controls and ovarian cancer patients were significantly discriminated using PGA (p=0.004), we got only similar results using SA (p=0.03) but not for ELISA. Our findings demonstrate that whilst assays were largely positively correlated, each presents unique characteristic features and should be validated by an independent patient cohort rather than another array technique. The variety between methods presumably reflects the differences in glycan presentation and the antigen/antibody ratio, assay conditions and detection technique. This indicates that the glycan-antibody interaction of interest has to guide the assay selection. © The Author(s) 2011. This article is published with open access at Springerlink.com

  7. A Compact VLSI System for Bio-Inspired Visual Motion Estimation.

    PubMed

    Shi, Cong; Luo, Gang

    2018-04-01

    This paper proposes a bio-inspired visual motion estimation algorithm based on motion energy, along with its compact very-large-scale integration (VLSI) architecture using low-cost embedded systems. The algorithm mimics motion perception functions of retina, V1, and MT neurons in a primate visual system. It involves operations of ternary edge extraction, spatiotemporal filtering, motion energy extraction, and velocity integration. Moreover, we propose the concept of confidence map to indicate the reliability of estimation results on each probing location. Our algorithm involves only additions and multiplications during runtime, which is suitable for low-cost hardware implementation. The proposed VLSI architecture employs multiple (frame, pixel, and operation) levels of pipeline and massively parallel processing arrays to boost the system performance. The array unit circuits are optimized to minimize hardware resource consumption. We have prototyped the proposed architecture on a low-cost field-programmable gate array platform (Zynq 7020) running at 53-MHz clock frequency. It achieved 30-frame/s real-time performance for velocity estimation on 160 × 120 probing locations. A comprehensive evaluation experiment showed that the estimated velocity by our prototype has relatively small errors (average endpoint error < 0.5 pixel and angular error < 10°) for most motion cases.

  8. Novel photonic technique creates micrometer resolution protein arrays and provides a new approach to coupling of genes, peptide hormones and drugs to nanoparticle carriers

    NASA Astrophysics Data System (ADS)

    Duroux, M.; Duroux, L.; Neves-Petersen, M. T.; Skovsen, E.; Petersen, S. B.

    2007-07-01

    We demonstrate that ultraviolet light can be used to make sterically oriented covalent immobilization of a large variety of protein molecules onto either thiolated quartz, gold or silicon. The reaction mechanism behind the reported new technology involves light-induced breakage of disulphide bridges in proteins upon UV illumination of nearby aromatic amino acids, resulting in the formation of free, reactive thiol groups that will form covalent bonds with thiol reactive surfaces. In general, the protein molecules retain their function. The size of the immobilization spot is limited to the focal point of illumination being as small as a few micrometers. This new technology allows for dense packing of different bio-molecules on a surface, allowing the creation of multi-potent functionalised new materials, such as nano-biosensors. We have developed the necessary technology for preparing large protein arrays of enzymes and fragments of monoclonal antibodies. Dedicated image processing software has been developed for making quality assessment of the protein arrays. This novel technology is ideal to couple drugs and other bio-molecules to nanoparticles which can be used as carriers into cells for therapeutic purposes.

  9. Fabrication and characterization of gold nano-wires templated on virus-like arrays of tobacco mosaic virus coat proteins

    NASA Astrophysics Data System (ADS)

    Wnęk, M.; Górzny, M. Ł.; Ward, M. B.; Wälti, C.; Davies, A. G.; Brydson, R.; Evans, S. D.; Stockley, P. G.

    2013-01-01

    The rod-shaped plant virus tobacco mosaic virus (TMV) is widely used as a nano-fabrication template, and chimeric peptide expression on its major coat protein has extended its potential applications. Here we describe a simple bacterial expression system for production and rapid purification of recombinant chimeric TMV coat protein carrying C-terminal peptide tags. These proteins do not bind TMV RNA or form disks at pH 7. However, they retain the ability to self-assemble into virus-like arrays at acidic pH. C-terminal peptide tags in such arrays are exposed on the protein surface, allowing interaction with target species. We have utilized a C-terminal His-tag to create virus coat protein-templated nano-rods able to bind gold nanoparticles uniformly. These can be transformed into gold nano-wires by deposition of additional gold atoms from solution, followed by thermal annealing. The resistivity of a typical annealed wire created by this approach is significantly less than values reported for other nano-wires made using different bio-templates. This expression construct is therefore a useful additional tool for the creation of chimeric TMV-like nano-rods for bio-templating.

  10. Bio-Inspired Bright Structurally Colored Colloidal Amorphous Array Enhanced by Controlling Thickness and Black Background.

    PubMed

    Iwata, Masanori; Teshima, Midori; Seki, Takahiro; Yoshioka, Shinya; Takeoka, Yukikazu

    2017-07-01

    Inspired by Steller's jay, which displays angle-independent structural colors, angle-independent structurally colored materials are created, which are composed of amorphous arrays of submicrometer-sized fine spherical silica colloidal particles. When the colloidal amorphous arrays are thick, they do not appear colorful but almost white. However, the saturation of the structural color can be increased by (i) appropriately controlling the thickness of the array and (ii) placing the black background substrate. This is similar in the case of the blue feather of Steller's jay. Based on the knowledge gained through the biomimicry of structural colored materials, colloidal amorphous arrays on the surface of a black particle as the core particle are also prepared as colorful photonic pigments. Moreover, a structural color on-off system is successfully built by controlling the background brightness of the colloidal amorphous arrays. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Counterion accumulation effects on a suspension of DNA molecules: Equation of state and pressure-driven denaturation

    NASA Astrophysics Data System (ADS)

    Nicasio-Collazo, Luz Adriana; Delgado-González, Alexandra; Hernández-Lemus, Enrique; Castañeda-Priego, Ramón

    2017-04-01

    The study of the effects associated with the electrostatic properties of DNA is of fundamental importance to understand both its molecular properties at the single molecule level, like the rigidity of the chain, and its interaction with other charged bio-molecules, including other DNA molecules; such interactions are crucial to maintain the thermodynamic stability of the intra-cellular medium. In the present work, we combine the Poisson-Boltzmann mean-field theory with an irreversible thermodynamic approximation to analyze the effects of counterion accumulation inside DNA on both the denaturation profile of the chain and the equation of state of the suspension. To this end, we model the DNA molecule as a porous charged cylinder immersed in an aqueous solution. These thermo-electrostatic effects are explicitly studied in the particular case of some genes for which damage in their sequence is associated with diffuse large B-cell lymphoma.

  12. Controlled confinement of DNA at the nanoscale: nanofabrication and surface bio-functionalization

    PubMed Central

    Palma, Matteo; Abramson, Justin; Gorodetsky, Alon; Nuckolls, Colin; Sheetz, Michael P.; Wind, Shalom J.; Hone, James

    2012-01-01

    Nanopatterned arrays of biomolecules are a powerful tool to address fundamental issues in many areas of biology. DNA nanoarrays, in particular, are of interest in the study of both DNA-protein interactions as well as for biodiagnostic investigations. In this context, achieving a highly specific nanoscale assembly of oligonulceotides at surfaces is critical. In this chapter we describe a method to control the immobilization of DNA on nanopatterned surfaces: the nanofabrication and the bio-functionalization involved in the process will be discussed. PMID:21674372

  13. Platelet lysate as a serum replacement for skin cell culture on biomimetic PCL nanofibers.

    PubMed

    Sovkova, Vera; Vocetkova, Karolina; Rampichova, Michala; Mickova, Andrea; Buzgo, Matej; Lukasova, Vera; Dankova, Jana; Filova, Eva; Necas, Alois; Amler, Evzen

    2018-06-01

    Platelets are a popular source of native growth factors for tissue engineering applications. The aim of the study was to verify the use of platelet lysate as a fetal bovine serum (FBS) replacement for skin cell culture. The cytokine content of the platelet lysate was characterized using the Bio-Plex system. The cells (fibroblasts, melanocytes, and keratinocytes) were cultured on PCL nanofibrous scaffolds to mimic their natural microenvironment. The cytokine content of the platelet lysate was determined, and to the cells, a medium containing platelet lysate or platelet lysate in combination with FBS was added. The results showed that 7% (v/v) platelet lysate was sufficient to supplement 10% (v/v) FBS in the culture of fibroblasts and keratinocytes. The combination of platelet lysate and FBS had a rather inhibitory effect on fibroblasts, in contrary to keratinocytes, where the effect was synergic. Platelet lysate did not sufficiently promote proliferation in melanocytes; however, the combination of FBS and platelet lysate yielded a better outcome and resulted in bipolar morphology of the cultured melanocytes. The data indicated that platelet lysate improved cell proliferation and metabolic activity and may be used as an additive to the cell culture media.

  14. Development of Conceptual Design Support Tool Founded on Formalization of Conceptual Design Process for Regenerative Life Support Systems

    NASA Astrophysics Data System (ADS)

    Miyajima, Hiroyuki; Yuhara, Naohiro

    Regenerative Life Support Systems (RLSS), which maintain human lives by recycling substances essential for living, are comprised of humans, plants, and material circulation systems. The plants supply food to the humans or reproduce water and gases by photosynthesis, while the material circulation systems recycle physicochemically and circulate substances disposed by humans and plants. RLSS attracts attention since manned space activities have been shifted from previous short trips to long-term stay activities as such base as a space station, a lunar base, and a Mars base. The present typical space base is the International Space Station (ISS), a manned experimental base for prolonged stays, where RLSS recycles only water and air. In order to accommodate prolonged and extended manned activity in future space bases, developing RLSS that implements food production and regeneration of resources at once using plants is expected. The configuration of RLSS should be designed to suit its own duty, for which design requirements for RLSS with an unprecedented configuration may arise. Accordingly, it is necessary to establish a conceptual design method for generalized RLSS. It is difficult, however, to systematize the design process by analyzing previous design because there are only a few ground-experimental facilities, namely CEEF (Closed Ecology Experiment Facilities) of Japan, BIO-Plex (Bioregenerative Planetary Life Support Systems Test Complex) of the U.S., and BIOS3 of Russia. Thus a conceptual design method which doesn’t rely on previous design examples is required for generalized RLSS from the above reasons. This study formalizes a conceptual design process, and develops a conceptual design support tool for RLSS based on this design process.

  15. Rule-Based Motion Coordination for the Adaptive Suspension Vehicle on Ternary-Type Terrain

    DTIC Science & Technology

    1990-12-01

    robot-window-array* nil) (defvar *robot..window..width* nil) (defvar * rebot -.window..heig)ht* nil) (defvar *terrain-buffer* nil) (defvar *terrain...cond ((momrber leg lift-able-leg. -test #’equal) log) (t nil)) .(dafmethod (test-overlap- rebot ipltcable-leg) (log) (nond ((and (member leg place-able

  16. Coupling of bio-PRB and enclosed in-well aeration system for remediation of nitrobenzene and aniline in groundwater.

    PubMed

    Liu, Na; Ding, Feng; Wang, Liu; Liu, Peng; Yu, Xiaolong; Ye, Kang

    2016-05-01

    A laboratory-scale bio-permeable reactive barrier (bio-PRB) was constructed and combined with enclosed in-well aeration system to treat nitrobenzene (NB) and aniline (AN) in groundwater. Batch-style experiments were first conducted to evaluate the effectiveness of NB and AN degradation, using suspension (free cells) of degrading consortium and immobilized consortium by a mixture of perlite and peat. The NB and AN were completely degraded in <3 days using immobilized consortium, while 3-5 days were required using free cells. The O2 supply efficiency of an enclosed in-well aeration system was assessed in a box filled with perlite and peat. Dissolved O2 (DO) concentrations increased to 8-12 mg L(-1) in 12 h for sampling ports within 12 cm of the aeration well. A diffusion coefficient as 33.5 cm(2) s(-1) was obtained. The DO concentration was >4 mg L(-1) when the aeration system was applied into the bio-PRB system. The NB and AN were effectively removed when the aeration system was functional in the bio-PRB. The removal efficiency decreased when the aeration system malfunctioned for 20 days, thus indicating that DO was an important factor for the degradation of NB and AN. The regain of NB and AN removal after the malfunction indicates the robustness of degradation consortium. No original organics and new formed by-products were observed in the effluent. The results indicate that NB and AN in groundwater can be completely mineralized in a bio-PRB equipped with enclosed in-well aeration system and filled with perlite and peat attached with degrading consortium.

  17. Myasthenia Gravis Impairment Index: Responsiveness, meaningful change, and relative efficiency.

    PubMed

    Barnett, Carolina; Bril, Vera; Kapral, Moira; Kulkarni, Abhaya V; Davis, Aileen M

    2017-12-05

    To study responsiveness and meaningful change of the Myasthenia Gravis Impairment Index (MGII) and its relative efficiency compared to other measures. We enrolled 95 patients receiving prednisone, IV immunoglobulin (IVIg), or plasma exchange (PLEX) and 54 controls. Patients were assessed with the MGII and other measures-including the Quantitative Myasthenia Gravis Score, Myasthenia Gravis Composite, and Myasthenia Gravis Activities of Daily Living-at baseline and 3-4 weeks after treatment. Statistical markers of responsiveness included between-groups and within-group differences, and we estimated the relative efficiency of the MGII compared to other measures. Patient-meaningful change was assessed with an anchor-based method, using the patient's impression of change. We determined the minimal detectable change (MDC) and the minimal important difference (MID) at the group and individual level. Treated patients had a higher change in MGII scores than controls (analysis of covariance p < 0.001). The ocular domain changed more with prednisone than with IVIg/PLEX (effect size 0.67 and 0.13, analysis of covariance p = 0.001). The generalized domain changed more with IVIg/PLEX than with prednisone (effect size 0.50 and 0.22, analysis of covariance p = 0.07). For the total MGII score, the individual MDC95 was 9.1 and the MID was 5.5 for individuals and 8.1 for groups. Relative efficiency ratios were >1 favoring the MGII. The MGII demonstrated responsiveness to prednisone, IVIg, and PLEX in patients with myasthenia. There is a differential response in ocular and generalized symptoms to type of therapy. The MGII has higher relative efficiency than comparison measures and is viable for use in clinical trials. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  18. Inference of biogeographical ancestry across central regions of Eurasia.

    PubMed

    Bulbul, O; Filoglu, G; Zorlu, T; Altuncul, H; Freire-Aradas, A; Söchtig, J; Ruiz, Y; Klintschar, M; Triki-Fendri, S; Rebai, A; Phillips, C; Lareu, M V; Carracedo, Á; Schneider, P M

    2016-01-01

    The inference of biogeographical ancestry (BGA) can provide useful information for forensic investigators when there are no suspects to be compared with DNA collected at the crime scene or when no DNA database matches exist. Although public databases are increasing in size and population scope, there is a lack of information regarding genetic variation in Eurasian populations, especially in central regions such as the Middle East. Inhabitants of these regions show a high degree of genetic admixture, characterized by an allele frequency cline running from NW Europe to East Asia. Although a proper differentiation has been established between the cline extremes of western Europe and South Asia, populations geographically located in between, i.e, Middle East and Mediterranean populations, require more detailed study in order to characterize their genetic background as well as to further understand their demographic histories. To initiate these studies, three ancestry informative SNP (AI-SNP) multiplex panels: the SNPforID 34-plex, Eurasiaplex and a novel 33-plex assay were used to describe the ancestry patterns of a total of 24 populations ranging across the longitudinal axis from NW Europe to East Asia. Different ancestry inference approaches, including STRUCTURE, PCA, DAPC and Snipper Bayes analysis, were applied to determine relationships among populations. The structure results show differentiation between continental groups and a NW to SE allele frequency cline running across Eurasian populations. This study adds useful population data that could be used as reference genotypes for future ancestry investigations in forensic cases. The 33-plex assay also includes pigmentation predictive SNPs, but this study primarily focused on Eurasian population differentiation using 33-plex and its combination with the other two AI-SNP sets.

  19. Eurasiaplex: a forensic SNP assay for differentiating European and South Asian ancestries.

    PubMed

    Phillips, C; Freire Aradas, A; Kriegel, A K; Fondevila, M; Bulbul, O; Santos, C; Serrulla Rech, F; Perez Carceles, M D; Carracedo, Á; Schneider, P M; Lareu, M V

    2013-05-01

    We have selected a set of single nucleotide polymorphisms (SNPs) with the specific aim of differentiating European and South Asian ancestries. The SNPs were combined into a 23-plex SNaPshot primer extension assay: Eurasiaplex, designed to complement an existing 34-plex forensic ancestry test with both marker sets occupying well-spaced genomic positions, enabling their combination as single profile submissions to the Bayesian Snipper forensic ancestry inference system. We analyzed the ability of Eurasiaplex plus 34plex SNPs to assign ancestry to a total 1648 profiles from 16 European, 7 Middle East, 13 Central-South Asian and 21 East Asian populations. Ancestry assignment likelihoods were estimated from Snipper using training sets of five-group data (three Eurasian groups, East Asian and African genotypes) and four-group data (Middle East genotypes removed). Five-group differentiations gave assignment success of 91% for NW European populations, 72% for Middle East populations and 39% for Central-South Asian populations, indicating Middle East individuals are not reliably differentiated from either Europeans or Central-South Asians. Four-group differentiations provided markedly improved assignment success rates of 97% for most continental Europeans tested (excluding Turkish and Adygei at the far eastern edge of Europe) and 95% for Central-South Asians, despite applying a probability threshold for the highest likelihood ratio above '100 times more likely'. As part of the assessment of the sensitivity of Eurasiaplex to analyze challenging forensic material we detail Eurasiaplex and 34-plex SNP typing to infer ancestry of a cranium recovered from the sea, achieving 82% SNP genotype completeness. Therefore, Eurasiaplex provides an informative and forensically robust approach to the differentiation of European and South Asian ancestries amongst Eurasian populations. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Effects of a hypocaloric diet on obesity biomarkers: prevention of low-grade inflammation since childhood.

    PubMed

    Amati, L; Marzulli, G; Martulli, M; Chiloiro, M; Jirillo, E

    2010-01-01

    Body mass index (BMI), serum cytokines and serum obesity markers were evaluated in 33 obese children before, during and after a hypocaloric diet. The cytometric bead array "human inflammatory kit" was used for the evaluation of serum interleukin (IL)-1beta, IL-6, IL-10 and tumor necrosis factor-alpha. On the other hand, the following obesity biomarkers were evaluated by means of a flowcytomix-human obesity 9 plex kit: Soluble Isoform of CD40 Ligand; Soluble Intercellular Adhesion Molecule-1; Leptin; Monocyte Chemoattractant Protein 1; Myeloperoxidase; Osteoprotegerin; Resistin and Soluble TNF-receptors. Actually, throughout the study modifications of BMI were negligible and, therefore, serum cytokines and obesity markers did not show any significant changes in comparison with baseline values. On the other hand, at the different time points considered the majority of obesity markers were higher than normal controls, thus indicating a low grade inflammation in childhood obesity. Therefore, attempts at reducing this inflammatory status in children which predisposes to the metabolic syndrome outcome are discussed.

  1. A bio-image sensor for simultaneous detection of multi-neurotransmitters.

    PubMed

    Lee, You-Na; Okumura, Koichi; Horio, Tomoko; Iwata, Tatsuya; Takahashi, Kazuhiro; Hattori, Toshiaki; Sawada, Kazuaki

    2018-03-01

    We report here a new bio-image sensor for simultaneous detection of spatial and temporal distribution of multi-neurotransmitters. It consists of multiple enzyme-immobilized membranes on a 128 × 128 pixel array with read-out circuit. Apyrase and acetylcholinesterase (AChE), as selective elements, are used to recognize adenosine 5'-triphosphate (ATP) and acetylcholine (ACh), respectively. To enhance the spatial resolution, hydrogen ion (H + ) diffusion barrier layers are deposited on top of the bio-image sensor and demonstrated their prevention capability. The results are used to design the space among enzyme-immobilized pixels and the null H + sensor to minimize the undesired signal overlap by H + diffusion. Using this bio-image sensor, we can obtain H + diffusion-independent imaging of concentration gradients of ATP and ACh in real-time. The sensing characteristics, such as sensitivity and detection of limit, are determined experimentally. With the proposed bio-image sensor the possibility exists for customizable monitoring of the activities of various neurochemicals by using different kinds of proton-consuming or generating enzymes. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Analysis of particle in liquid using excitation-fluorescence spectral flow cytometer

    NASA Astrophysics Data System (ADS)

    Takenaka, Kei; Togashi, Shigenori

    2018-01-01

    We have developed a new flow cytometer that can measure the excitation-fluorescence spectra of a single particle. This system consists of a solution-transmitting unit and an optical unit. The solution-transmitting unit allows a sample containing particles to flow through the center of a flow cell by hydrodynamic focusing. The optical unit irradiates particles with dispersed white light (wavelength band: 400-650 nm) along the flow direction and measures their fluorescence spectra (wavelength band: 400-700 nm) using a spectroscopic photodetector array. The fluorescence spectrum of a particle changes with the shift of the wavelength of the excitation light. Using this system, the excitation-fluorescence spectra of a fluorescent particle were measured. Additionally, a homogenized tomato suspension and a homogenized spinach suspension were measured using the system. Measurement results show that it is possible to determine the components of vegetables by comparing measured fluorescence spectra of particles in a vegetable suspension.

  3. Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method

    PubMed Central

    Chen, Keyun; Ren, Lei; Chen, Zhipeng; Pan, Chengfeng; Zhou, Wei; Jiang, Lelun

    2016-01-01

    Micro-needle electrodes (MEs) have attracted more and more attention for monitoring physiological electrical signals, including electrode-skin interface impedance (EII), electromyography (EMG) and electrocardiography (ECG) recording. A magnetization-induced self-assembling method (MSM) was developed to fabricate a microneedle array (MA). A MA coated with Ti/Au film was assembled as a ME. The fracture and insertion properties of ME were tested by experiments. The bio-signal recording performance of the ME was measured and compared with a typical commercial wet electrode (Ag/AgCl electrode). The results show that the MA self-assembled from the magnetic droplet array under the sum of gravitational surface tension and magnetic potential energies. The ME had good toughness and could easily pierce rabbit skin without being broken or buckling. When the compression force applied on the ME was larger than 2 N, ME could stably record EII, which was a lower value than that measured by Ag/AgCl electrodes. EMG signals collected by ME varied along with the contraction of biceps brachii muscle. ME could record static ECG signals with a larger amplitude and dynamic ECG signals with more distinguishable features in comparison with a Ag/AgCl electrode, therefore, ME is an alternative electrode for bio-signal monitoring in some specific situations. PMID:27657072

  4. Enhanced hydrolysis of cellulose hydrogels by morphological modification.

    PubMed

    Alfassi, Gilad; Rein, Dmitry M; Cohen, Yachin

    2017-11-01

    Cellulose is one of the most abundant bio-renewable materials on earth, yet the potential of cellulosic bio-fuels is not fully exploited, primarily due to the high costs of conversion. Hydrogel particles of regenerated cellulose constitute a useful substrate for enzymatic hydrolysis, due to their porous and amorphous structure. This article describes the influence of several structural aspects of the cellulose hydrogel on its hydrolysis. The hydrogel density was shown to be directly proportional to the cellulose concentration in the initial solution, thus affecting its hydrolysis rate. Using high-resolution scanning electron microscopy, we show that the hydrogel particles in aqueous suspension exhibit a dense external surface layer and a more porous internal network. Elimination of the external surface layer accelerated the hydrolysis rate by up to sixfold and rendered the process nearly independent of cellulose concentration. These findings may be of practical relevance to saccharification processing costs, by reducing required solvent quantities and enzyme load.

  5. Bio-inspired self-shaping ceramics

    PubMed Central

    Bargardi, Fabio L.; Le Ferrand, Hortense; Libanori, Rafael; Studart, André R.

    2016-01-01

    Shaping ceramics into complex and intricate geometries using cost-effective processes is desirable in many applications but still remains an open challenge. Inspired by plant seed dispersal units that self-fold on differential swelling, we demonstrate that self-shaping can be implemented in ceramics by programming the material's microstructure to undergo local anisotropic shrinkage during heat treatment. Such microstructural design is achieved by magnetically aligning functionalized ceramic platelets in a liquid ceramic suspension, subsequently consolidated through an established enzyme-catalysed reaction. By fabricating alumina compacts exhibiting bio-inspired bilayer architectures, we achieve deliberate control over shape change during the sintering step. Bending, twisting or combinations of these two basic movements can be successfully programmed to obtain a myriad of complex shapes. The simplicity and the universality of such a bottom-up shaping method makes it attractive for applications that would benefit from low-waste ceramic fabrication, temperature-resistant interlocking structures or unusual geometries not accessible using conventional top–down manufacturing. PMID:28008930

  6. Bio-inspired self-shaping ceramics

    NASA Astrophysics Data System (ADS)

    Bargardi, Fabio L.; Le Ferrand, Hortense; Libanori, Rafael; Studart, André R.

    2016-12-01

    Shaping ceramics into complex and intricate geometries using cost-effective processes is desirable in many applications but still remains an open challenge. Inspired by plant seed dispersal units that self-fold on differential swelling, we demonstrate that self-shaping can be implemented in ceramics by programming the material's microstructure to undergo local anisotropic shrinkage during heat treatment. Such microstructural design is achieved by magnetically aligning functionalized ceramic platelets in a liquid ceramic suspension, subsequently consolidated through an established enzyme-catalysed reaction. By fabricating alumina compacts exhibiting bio-inspired bilayer architectures, we achieve deliberate control over shape change during the sintering step. Bending, twisting or combinations of these two basic movements can be successfully programmed to obtain a myriad of complex shapes. The simplicity and the universality of such a bottom-up shaping method makes it attractive for applications that would benefit from low-waste ceramic fabrication, temperature-resistant interlocking structures or unusual geometries not accessible using conventional top-down manufacturing.

  7. Transcriptional Profiling of Human Peripheral Blood Mononuclear Cells Exposed to Bacillus anthracis in vitro

    DTIC Science & Technology

    2013-03-11

    are derived from the combination of three polypeptides, namely the Protective antigen (PA, 83 kDa), the edema factor (EF, 89 kDa), and the lethal...p38MAPK-dependent pathways. The T-cell receptors and CD3-mediated antigenic recognition processes are possibly restrained, and the expression of CD79...NY), using a VersArray microarrayer ( Bio -Rad, CA). Arrays were post- processed using UV-cross linking at 1200 mJ/cm2, followed by baking for 4 hrs

  8. Fluorescence-based bioassays for the detection and evaluation of food materials.

    PubMed

    Nishi, Kentaro; Isobe, Shin-Ichiro; Zhu, Yun; Kiyama, Ryoiti

    2015-10-13

    We summarize here the recent progress in fluorescence-based bioassays for the detection and evaluation of food materials by focusing on fluorescent dyes used in bioassays and applications of these assays for food safety, quality and efficacy. Fluorescent dyes have been used in various bioassays, such as biosensing, cell assay, energy transfer-based assay, probing, protein/immunological assay and microarray/biochip assay. Among the arrays used in microarray/biochip assay, fluorescence-based microarrays/biochips, such as antibody/protein microarrays, bead/suspension arrays, capillary/sensor arrays, DNA microarrays/polymerase chain reaction (PCR)-based arrays, glycan/lectin arrays, immunoassay/enzyme-linked immunosorbent assay (ELISA)-based arrays, microfluidic chips and tissue arrays, have been developed and used for the assessment of allergy/poisoning/toxicity, contamination and efficacy/mechanism, and quality control/safety. DNA microarray assays have been used widely for food safety and quality as well as searches for active components. DNA microarray-based gene expression profiling may be useful for such purposes due to its advantages in the evaluation of pathway-based intracellular signaling in response to food materials.

  9. Fluorescence-Based Bioassays for the Detection and Evaluation of Food Materials

    PubMed Central

    Nishi, Kentaro; Isobe, Shin-Ichiro; Zhu, Yun; Kiyama, Ryoiti

    2015-01-01

    We summarize here the recent progress in fluorescence-based bioassays for the detection and evaluation of food materials by focusing on fluorescent dyes used in bioassays and applications of these assays for food safety, quality and efficacy. Fluorescent dyes have been used in various bioassays, such as biosensing, cell assay, energy transfer-based assay, probing, protein/immunological assay and microarray/biochip assay. Among the arrays used in microarray/biochip assay, fluorescence-based microarrays/biochips, such as antibody/protein microarrays, bead/suspension arrays, capillary/sensor arrays, DNA microarrays/polymerase chain reaction (PCR)-based arrays, glycan/lectin arrays, immunoassay/enzyme-linked immunosorbent assay (ELISA)-based arrays, microfluidic chips and tissue arrays, have been developed and used for the assessment of allergy/poisoning/toxicity, contamination and efficacy/mechanism, and quality control/safety. DNA microarray assays have been used widely for food safety and quality as well as searches for active components. DNA microarray-based gene expression profiling may be useful for such purposes due to its advantages in the evaluation of pathway-based intracellular signaling in response to food materials. PMID:26473869

  10. Recognition of Y Fragment Deletion by Genotyping Graphs after Amplified by PowerPlex® 21 Detection Kit.

    PubMed

    Wang, S C; Ding, M M; Wei, X L; Zhang, T; Yao, F

    2016-06-01

    To recognize the possibility of Y fragment deletion of Amelogenin gene intuitively and simply according to the genotyping graphs. By calculating the ratio of total peak height of genotyping graphs, the statistics of equilibrium distribution between Amelogenin and D3S1358 loci, Amelogenin X-gene and Amelogenin Y-gene, and different alleles of D3S1358 loci from 1 968 individuals was analyzed after amplified by PowerPlex ® 21 detection kit. Sum of peak height of Amelogenin X allele was not less than 60% that of D3S1358 loci alleles in 90.8% female samples, and sum of peak height of Amelogenin X allele was not higher than 70% that of D3S1358 loci alleles in 94.9% male samples. The result of genotyping after amplified by PowerPlex ® 21 detection kit shows that the possibility of Y fragment deletion should be considered when only Amelogenin X-gene of Amelogenin is detected and the peak height of Amelogenin X-gene is not higher than 70% of the total peak height of D3S1358 loci. Copyright© by the Editorial Department of Journal of Forensic Medicine

  11. Detection of respiratory viruses on air filters from aircraft.

    PubMed

    Korves, T M; Johnson, D; Jones, B W; Watson, J; Wolk, D M; Hwang, G M

    2011-09-01

    To evaluate the feasibility of identifying viruses from aircraft cabin air, we evaluated whether respiratory viruses trapped by commercial aircraft air filters can be extracted and detected using a multiplex PCR, bead-based assay. The ResPlex II assay was first tested for its ability to detect inactivated viruses applied to new filter material; all 18 applications of virus at a high concentration were detected. The ResPlex II assay was then used to test for 18 respiratory viruses on 48 used air filter samples from commercial aircraft. Three samples tested positive for viruses, and three viruses were detected: rhinovirus, influenza A and influenza B. For 33 of 48 samples, internal PCR controls performed suboptimally, suggesting sample matrix effect. In some cases, influenza and rhinovirus RNA can be detected on aircraft air filters, even more than 10 days after the filters were removed from aircraft. With protocol modifications to overcome PCR inhibition, air filter sampling and the ResPlex II assay could be used to characterize viruses in aircraft cabin air. Information about viruses in aircraft could support public health measures to reduce disease transmission within aircraft and between cities. © The MITRE corporation. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  12. Two brothers' alleged paternity for a child: who is the father?

    PubMed

    Dogan, Muhammed; Kara, Umut; Emre, Ramazan; Fung, Wing Kam; Canturk, Kemal Murat

    2015-06-01

    In paternity cases where individuals are close relatives, it may be necessary to evaluate mother's DNA profile (trio test) and to increase the number of polymorphic STR loci that are analyzed. In our case, two alleged fathers who are brothers and the child (duo case) were analyzed based on 20 STR loci; however, no exclusions could be achieved. Then trio test (with mother) was performed using the Identifiler Plus kit (Applied Biosystems) and no exclusions could be achieved again. Analysis performed with the ESS Plex Plus kit (Qiagen), the paternity of one of the two alleged fathers was rejected only on 2 STR loci. We made the calculations of power of exclusion values to interpret our results more properly. The probability of exclusion (PE) is calculated as 0.9776546 in 15 loci of Identifiler Plus kit without mother. The PE is calculated as 0.9942803, if 5 additional loci from ESS Plex Plus kit are typed. The PE becomes 0.9961048 for the Identifiler Plus kit in trio analysis. If both Identifiler Plus and ESS Plex Plus kits are used for testing, the PE is calculated as 0.999431654, which indicates that the combined kits are highly discriminating.

  13. Simultaneous Detection of Antibodies against Apx Toxins ApxI, ApxII, ApxIII, and ApxIV in Pigs with Known and Unknown Actinobacillus pleuropneumoniae Exposure Using a Multiplexing Liquid Array Platform

    PubMed Central

    Giménez-Lirola, Luis G.; Jiang, Yong-Hou; Sun, Dong; Hoang, Hai; Yoon, Kyoung-Jin; Halbur, Patrick G.

    2014-01-01

    Surveillance for the presence of Actinobacillus pleuropneumoniae infection in a population plays a central role in controlling the disease. In this study, a 4-plex fluorescent microbead-based immunoassay (FMIA), developed for the simultaneous detection of IgG antibodies to repeat-in-toxin (RTX) toxins (ApxI, ApxII, ApxIII, and ApxIV) of A. pleuropneumoniae, was evaluated using (i) blood serum samples from pigs experimentally infected with each of the 15 known A. pleuropneumoniae serovars or with Actinobacillus suis, (ii) blood serum samples from pigs vaccinated with a bacterin containing A. pleuropneumoniae serovar 1, 3, 5, or 7, and (iii) blood serum samples from pigs with an unknown A. pleuropneumoniae exposure status. The results were compared to those obtained in a previous study where a dual-plate complement fixation test (CFT) and three commercially available enzyme-linked immunosorbent assays (ELISAs) were conducted on the same sample set. On samples from experimentally infected pigs, the 4-plex Apx FMIA detected specific seroconversion to Apx toxins as early as 7 days postinfection in a total of 29 pigs inoculated with 14 of the 15 A. pleuropneumoniae serovars. Seroconversion to ApxII and ApxIII was detected by FMIA in pigs inoculated with A. suis. The vaccinated pigs showed poor humoral responses against ApxI, ApxII, ApxIII, and ApxIV. In the field samples, the humoral response to ApxIV and the A. pleuropneumoniae seroprevalence increased with age. This novel FMIA (with a sensitivity of 82.7% and a specificity of 100% for the anti-ApxIV antibody) was found to be more sensitive and accurate than current tests (sensitivities, 9.5 to 56%; specificity, 100%) and is potentially an improved tool for the surveillance of disease and for monitoring vaccination compliance. PMID:24226091

  14. Analysis of switchgrass-derived bio-oil and associated aqueous phase generated in a semi-pilot scale auger pyrolyzer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ren, Shoujie; Ye, X. Philip; Borole, Abhijeet P.

    To efficiently utilize water-soluble compounds in bio-oil and evaluate the potential effects of these compounds on processes such as microbial electrolysis, our study investigated the physico-chemical properties of bio-oil and the associated aqueous phase generated from switchgrass using a semi-pilot scale auger pyrolyzer. Combining separation and detection strategies with organic solvent extraction, an array of analytical instruments and methods were used to identify and quantify the chemical constituents. Separation of an aqueous phase from crude bio-oil was achieved by adding water (water: crude bio-oil at 4:1 in weight), which resulted in a partition of 61 wt.% of the organic compoundsmore » into a bio-oil aqueous phase (BOAP). GC/MS analysis for BOAP identified over 40 compounds of which 16 were quantified. Acetic acid, propionic acid, and levoglucosan are the major components in BOAP. In addition, a significant portion of chemicals that have the potential to be upgraded to hydrocarbon fuels were extracted to BOAP (77 wt.% of the alcohols, 61 wt.% of the furans, and 52 wt.% of the phenolic compounds in crude bio-oil). Valorization of the BOAP may require conversion methods capable of accommodating a very broad substrate specificity. Ultimately, a better separation strategy is needed to selectively remove the acidic and polar components from crude bio-oil to improve economic feasibility of biorefinery operations.« less

  15. Analysis of switchgrass-derived bio-oil and associated aqueous phase generated in a semi-pilot scale auger pyrolyzer

    DOE PAGES

    Ren, Shoujie; Ye, X. Philip; Borole, Abhijeet P.; ...

    2016-03-30

    To efficiently utilize water-soluble compounds in bio-oil and evaluate the potential effects of these compounds on processes such as microbial electrolysis, our study investigated the physico-chemical properties of bio-oil and the associated aqueous phase generated from switchgrass using a semi-pilot scale auger pyrolyzer. Combining separation and detection strategies with organic solvent extraction, an array of analytical instruments and methods were used to identify and quantify the chemical constituents. Separation of an aqueous phase from crude bio-oil was achieved by adding water (water: crude bio-oil at 4:1 in weight), which resulted in a partition of 61 wt.% of the organic compoundsmore » into a bio-oil aqueous phase (BOAP). GC/MS analysis for BOAP identified over 40 compounds of which 16 were quantified. Acetic acid, propionic acid, and levoglucosan are the major components in BOAP. In addition, a significant portion of chemicals that have the potential to be upgraded to hydrocarbon fuels were extracted to BOAP (77 wt.% of the alcohols, 61 wt.% of the furans, and 52 wt.% of the phenolic compounds in crude bio-oil). Valorization of the BOAP may require conversion methods capable of accommodating a very broad substrate specificity. Ultimately, a better separation strategy is needed to selectively remove the acidic and polar components from crude bio-oil to improve economic feasibility of biorefinery operations.« less

  16. Mastering multi-depth bio-chip patterns with DVD LBRs

    NASA Astrophysics Data System (ADS)

    Carson, Doug

    2017-08-01

    Bio chip and bio disc are rapidly growing technologies used in medical, health and other industries. While there are numerous unique designs and features, these products all rely on precise three-dimensional micro-fluidic channels or arrays to move, separate and combine samples under test. These bio chip and bio disc consumables are typically manufactured by molding these parts to a precise three-dimensional pattern on a negative metal stamper, or they can be made in smaller quantities using an appropriate curable resin and a negative mold/stamper. Stampers required for bio chips have been traditionally made using either micro machining or XY stepping lithography. Both of these technologies have their advantages as well as limitations when it comes to creating micro-fluidic patterns. Significant breakthroughs in continuous maskless lithography have enabled accurate and efficient manufacturing of micro-fluidic masters using LBRs (Laser Beam Recorders) and DRIE (Deep Reactive Ion Etching). The important advantages of LBR continuous lithography vs. XY stepping lithography and micro machining are speed and cost. LBR based continuous lithography is >100x faster than XY stepping lithography and more accurate than micro machining. Several innovations were required in order to create multi-depth patterns with sub micron accuracy. By combining proven industrial LBRs with DCA's G3-VIA pattern generator and DRIE, three-dimensional bio chip masters and stampers are being manufactured efficiently and accurately.

  17. Uneven biofilm and current distribution in three-dimensional macroporous anodes of bio-electrochemical systems composed of graphite electrode arrays.

    PubMed

    Li, Jun; Hu, Linbin; Zhang, Liang; Ye, Ding-Ding; Zhu, Xun; Liao, Qiang

    2017-03-01

    A 3-D macroporous anode was constructed using different numbers of graphite rod arrays in fixed-volume bio-electrochemical systems (BESs), and the current and biofilm distribution were investigated by dividing the 3-D anode into several subunits. In the fixed-volume chamber, current production was not significantly improved after the electrode number increased to 36. In the case of 100 electrodes, a significant uneven current distribution was found in the macroporous anode. This was attributed to a differential pH distribution, which resulted from proton accumulation inside the macroporous anode. The pH distribution influenced the biofilm development and led to an uneven biofilm distribution. With respect to current generation, the uneven distribution of both the pH and biofilm contributed to the uneven current distribution. The center had a low pH, which led to less biofilm and a lower contribution to the total current, limiting the performance of the BESs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Novel and simple route to fabricate fully biocompatible plasmonic mushroom arrays adhered on silk biopolymer

    NASA Astrophysics Data System (ADS)

    Park, Joonhan; Choi, Yunkyoung; Lee, Myungjae; Jeon, Heonsu; Kim, Sunghwan

    2014-12-01

    A fully biocompatible plasmonic quasi-3D nanostructure is demonstrated by a simple and reliable fabrication method using strong adhesion between gold and silk fibroin. The quasi-3D nature gives rise to complex photonic responses in reflectance that are prospectively useful in bio/chemical sensing applications. Laser interference lithography is utilized to fabricate large-area plasmonic nanostructures.A fully biocompatible plasmonic quasi-3D nanostructure is demonstrated by a simple and reliable fabrication method using strong adhesion between gold and silk fibroin. The quasi-3D nature gives rise to complex photonic responses in reflectance that are prospectively useful in bio/chemical sensing applications. Laser interference lithography is utilized to fabricate large-area plasmonic nanostructures. Electronic supplementary information (ESI) available: The incident angle dependence of reflectance spectra and the atomic force microscopy image of the Au nanoparticle array on a silk film after 1 hour of ultrasonication. See DOI: 10.1039/c4nr05172f

  19. Programmable Nano-Bio-Chip Sensors: Analytical Meets Clinical

    PubMed Central

    Jokerst, Jesse V.; Floriano, Pierre N.; Christodoulides, Nicolaos; McDevitt, John T.; Jacobson, James W.; Bhagwandin, Bryon D.

    2010-01-01

    synopsis There have been many recent advances in the nano-bio-chip (NBC) analysis methodology with implications for a number of high-morbidity diseases including HIV, cancer, and heart disease. In their Feature article, Jesse V. Jokerst of The University of Texas at Austin; Pierre N. Floriano, Nicolaos Christodoulides, and John T. McDevitt of Rice University; and James W. Jacobson and Bryon D. Bhagwandin of LabNow, Inc. discuss the construction, capabilities, and advantages of NBCs. The cover shows arrays of NBCs. Images courtesy of Glennon Simmons/McDevitt Lab and Marcha Miller of The University of Texas at Austin. PMID:20128622

  20. Hierarchical Ni0.54Co0.46O2 nanowire and nanosheet arrays grown on carbon fiber cloth for high-performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Jiang, Yuanzhi; Zhang, Lijuan; Zhang, Hang; Zhang, Cui; Liu, Shuangxi

    2016-10-01

    Hierarchical Ni0.54Co0.46O2 architectures composed by nanowires or nanosheets were successfully grown on bio-mass carbon fiber cloth (CFC) by hydrothermal method. The morphology of Ni0.54Co0.46O2 can be effectively controlled by using different precipitators. The structural effects of the two kinds of morphologies were researched. the results suggest that the Ni0.54Co0.46O2 nanosheet arrays grown on CFC (NCO-NSs/CFC) shows a higher Faradaic areal capacity of 438 μAh cm-2 (238.1 mAh g-1) at a current density of 1 mA cm-2 and still about 90.3% initial capacity retention even at the high current density of 50 mA cm-2. Moreover, an all-solid-state flexible symmetric supercapacitor device has been successfully assembled. The optimized device delivers superior electrochemical performance with an outstanding energy density of 92.4 Wh kg-1 at a power density of 207.2 W kg-1. Such hierarchical nanostructure composed by well-aligned uniform Ni0.54Co0.46O2 nanosheet arrays grown on bio-mass carbon fiber cloth might hold great promise as battery-type electrode material for high-performance supercapacitor.

  1. Silicon nanodisk array with a fin field-effect transistor for time-domain weighted sum calculation toward massively parallel spiking neural networks

    NASA Astrophysics Data System (ADS)

    Tohara, Takashi; Liang, Haichao; Tanaka, Hirofumi; Igarashi, Makoto; Samukawa, Seiji; Endo, Kazuhiko; Takahashi, Yasuo; Morie, Takashi

    2016-03-01

    A nanodisk array connected with a fin field-effect transistor is fabricated and analyzed for spiking neural network applications. This nanodevice performs weighted sums in the time domain using rising slopes of responses triggered by input spike pulses. The nanodisk arrays, which act as a resistance of several giga-ohms, are fabricated using a self-assembly bio-nano-template technique. Weighted sums are achieved with an energy dissipation on the order of 1 fJ, where the number of inputs can be more than one hundred. This amount of energy is several orders of magnitude lower than that of conventional digital processors.

  2. On-chip visual perception of motion: a bio-inspired connectionist model on FPGA.

    PubMed

    Torres-Huitzil, César; Girau, Bernard; Castellanos-Sánchez, Claudio

    2005-01-01

    Visual motion provides useful information to understand the dynamics of a scene to allow intelligent systems interact with their environment. Motion computation is usually restricted by real time requirements that need the design and implementation of specific hardware architectures. In this paper, the design of hardware architecture for a bio-inspired neural model for motion estimation is presented. The motion estimation is based on a strongly localized bio-inspired connectionist model with a particular adaptation of spatio-temporal Gabor-like filtering. The architecture is constituted by three main modules that perform spatial, temporal, and excitatory-inhibitory connectionist processing. The biomimetic architecture is modeled, simulated and validated in VHDL. The synthesis results on a Field Programmable Gate Array (FPGA) device show the potential achievement of real-time performance at an affordable silicon area.

  3. The Closure of the Cycle: Enzymatic Synthesis and Functionalization of Bio-Based Polyesters.

    PubMed

    Pellis, Alessandro; Herrero Acero, Enrique; Ferrario, Valerio; Ribitsch, Doris; Guebitz, Georg M; Gardossi, Lucia

    2016-04-01

    The polymer industry is under pressure to mitigate the environmental cost of petrol-based plastics. Biotechnologies contribute to the gradual replacement of petrol-based chemistry and the development of new renewable products, leading to the closure of carbon circle. An array of bio-based building blocks is already available on an industrial scale and is boosting the development of new generations of sustainable and functionally competitive polymers, such as polylactic acid (PLA). Biocatalysts add higher value to bio-based polymers by catalyzing not only their selective modification, but also their synthesis under mild and controlled conditions. The ultimate aim is the introduction of chemical functionalities on the surface of the polymer while retaining its bulk properties, thus enlarging the spectrum of advanced applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Development of a Bio-nanobattery for Distributed Power Storage Systems

    NASA Technical Reports Server (NTRS)

    King, Glen C.; Choi, Sang H.; Chu, Sang-Hyon; Kim, Jae-Woo; Park, Yeonjoon; Lillehei, Peter; Watt, Gerald D.; Davis, Robert; Harb, John N.

    2004-01-01

    Currently available power storage systems, such as those used to supply power to microelectronic devices, typically consist of a single centralized canister and a series of wires to supply electrical power to where it is needed in a circuit. As the size of electrical circuits and components become smaller, there exists a need for a distributed power system to reduce Joule heating, wiring, and to allow autonomous operation of the various functions performed by the circuit. Our research is being conducted to develop a bio-nanobattery using ferritins reconstituted with both an iron core (Fe-ferritin) and a cobalt core (Co-ferritin). Both Co-ferritin and Fe-ferritin were synthesized and characterized as candidates for the bio-nanobattery. The reducing capability was determined as well as the half-cell electrical potentials, indicating an electrical output of nearly 0.5 V for the battery cell. Ferritins having other metallic cores are also being investigated, in order to increase the overall electrical output. Two dimensional ferritin arrays were also produced on various substrates, demonstrating the necessary building blocks for the bio-nanobattery. The bio-nanobattery will play a key role in moving to a distributed power storage system for electronic applications.

  5. Constructing STR multiplex assays.

    PubMed

    Butler, John M

    2005-01-01

    Multiplex polymerase chain reaction (PCR) refers to the simultaneous amplification of multiple regions of deoxyribonucleic acid (DNA) using PCR. Commercial short tandem repeat (STR) assays that can coamplify as many as 16 different loci have become widely used in forensic DNA typing. This chapter will focus on some of the aspects of constructing robust STR multiplex assays, including careful design and quality control of PCR primers. Examples from the development of a cat STR 12plex and a human Y chromosome STR 20plex are used to illustrate the importance of various parts of the protocol. Primer design parameters and Internet-accessible resources are discussed, as are solutions to problems with residual dye artifacts that result from impure primers.

  6. Genetic diversity of Bacillus anthracis in Europe: genotyping methods in forensic and epidemiologic investigations.

    PubMed

    Derzelle, Sylviane; Thierry, Simon

    2013-09-01

    Bacillus anthracis, the etiological agent of anthrax, a zoonosis relatively common throughout the world, can be used as an agent of bioterrorism. In naturally occurring outbreaks and in criminal release of this pathogen, a fast and accurate diagnosis is crucial to an effective response. Microbiological forensics and epidemiologic investigations increasingly rely on molecular markers, such as polymorphisms in DNA sequence, to obtain reliable information regarding the identification or source of a suspicious strain. Over the past decade, significant research efforts have been undertaken to develop genotyping methods with increased power to differentiate B. anthracis strains. A growing number of DNA signatures have been identified and used to survey B. anthracis diversity in nature, leading to rapid advances in our understanding of the global population of this pathogen. This article provides an overview of the different phylogenetic subgroups distributed across the world, with a particular focus on Europe. Updated information on the anthrax situation in Europe is reported. A brief description of some of the work in progress in the work package 5.1 of the AniBioThreat project is also presented, including (1) the development of a robust typing tool based on a suspension array technology and multiplexed single nucleotide polymorphisms scoring and (2) the typing of a collection of DNA from European isolates exchanged between the partners of the project. The know-how acquired will contribute to improving the EU's ability to react rapidly when the identity and real origin of a strain need to be established.

  7. Ultrasonic diagnostic in porous media and suspensions

    NASA Astrophysics Data System (ADS)

    Bacri, J.-C.; Hoyos, M.; Rakotomalala, N.; Salin, D.; Bourlion, M.; Daccord, G.; Lenormand, R.; Soucemarianadin, S.

    1991-08-01

    An apparatus has been constructed to characterize transient fluid displacements in porous media, and probe sedimenting suspensions. The technique used is to propagate an ultrasonic wave in the sample. Both ultrasonic attenuation and velocity are related to the static and hydrodynamic properties of the medium. The system was built so as to perform array imaging (mapping) and tested with different fluids and suspensions. It is suggested that the ultrasonic technique can be suitable whenever transient, low cost and safe saturation and concentration measurements are to be performed. Nous avons réalisé un appareil pour étudier l'évolution temporelle des écoulements en milieux poreux et au cours de la sédimentation des suspensions. La technique employée utilise la propagation d'une onde ultrasonore dans l'échantillon. L'atténuation et la vitesse ultrasonores sont toutes deux reliées aux propriétés statique et dynamique du mileu. Le système d'imagerie acoustique permet une cartographie à deux dimensions de l'échantillon , ce système a été testé avec différents fluides et suspensions. Notre étude montre que la technique ultrasonore est bien adaptée à la détermination de la dépendance temporelle de la concentration et de la saturation dans des conditions de sécurité et de coût optimales.

  8. A Case Report of Recurrent Takotsubo Cardiomyopathy in a Patient during Myasthenia Crisis

    PubMed Central

    Battineni, Anusha; Mullaguri, Naresh; Thanki, Shail; Chockalingam, Anand

    2017-01-01

    Introduction Patients with myasthenia crisis can develop Takotsubo stress cardiomyopathy (SC) due to emotional or physical stress and high level of circulating catecholamines. We report a patient who developed recurrent Takotsubo cardiomyopathy during myasthenia crisis. Coexisting autoimmune disorders known to precipitate stress cardiomyopathy like Grave's disease need to be evaluated. Case Report A 69-year-old female with seropositive myasthenia gravis (MG), Grave's disease, and coronary artery disease on monthly infusion of intravenous immunoglobulin (IVIG), prednisone, pyridostigmine, and methimazole presented with shortness of breath and chest pain. Electrocardiogram (ECG) showed ST elevation in anterolateral leads with troponemia. Coronary angiogram was unremarkable for occlusive coronary disease with left ventriculogram showing reduced wall motion with apical and mid left ventricle (LV) hypokinesis suggestive of Takotsubo stress cardiomyopathy. Her symptoms were attributed to MG crisis. Her symptoms, ECG, and echocardiographic findings resolved after five cycles of plasma exchange (PLEX). She had another similar episode one year later during myasthenia crisis with subsequent resolution in 10 days after PLEX. Conclusion Takotsubo cardiomyopathy can be one of the manifestations of myasthenia crisis with or without coexisting Grave's disease. These patients might benefit from meticulous fluid status and cardiac monitoring while administering rescue treatments like IVIG and PLEX. PMID:29201468

  9. High-Resolution Enabled 12-Plex DiLeu Isobaric Tags for Quantitative Proteomics

    PubMed Central

    2015-01-01

    Multiplex isobaric tags (e.g., tandem mass tags (TMT) and isobaric tags for relative and absolute quantification (iTRAQ)) are a valuable tool for high-throughput mass spectrometry based quantitative proteomics. We have developed our own multiplex isobaric tags, DiLeu, that feature quantitative performance on par with commercial offerings but can be readily synthesized in-house as a cost-effective alternative. In this work, we achieve a 3-fold increase in the multiplexing capacity of the DiLeu reagent without increasing structural complexity by exploiting mass defects that arise from selective incorporation of 13C, 15N, and 2H stable isotopes in the reporter group. The inclusion of eight new reporter isotopologues that differ in mass from the existing four reporters by intervals of 6 mDa yields a 12-plex isobaric set that preserves the synthetic simplicity and quantitative performance of the original implementation. We show that the new reporter variants can be baseline-resolved in high-resolution higher-energy C-trap dissociation (HCD) spectra, and we demonstrate accurate 12-plex quantitation of a DiLeu-labeled Saccharomyces cerevisiae lysate digest via high-resolution nano liquid chromatography–tandem mass spectrometry (nanoLC–MS2) analysis on an Orbitrap Elite mass spectrometer. PMID:25405479

  10. Revision of the SNPforID 34-plex forensic ancestry test: Assay enhancements, standard reference sample genotypes and extended population studies.

    PubMed

    Fondevila, M; Phillips, C; Santos, C; Freire Aradas, A; Vallone, P M; Butler, J M; Lareu, M V; Carracedo, A

    2013-01-01

    A revision of an established 34 SNP forensic ancestry test has been made by swapping the under-performing rs727811 component SNP with the highly informative rs3827760 that shows a near-fixed East Asian specific allele. We collated SNP variability data for the revised SNP set in 66 reference populations from 1000 Genomes and HGDP-CEPH panels and used this as reference data to analyse four U.S. populations showing a range of admixture patterns. The U.S. Hispanics sample in particular displayed heterogeneous values of co-ancestry between European, Native American and African contributors, likely to reflect in part, the way this disparate group is defined using cultural as well as population genetic parameters. The genotyping of over 700 U.S. population samples also provided the opportunity to thoroughly gauge peak mobility variation and peak height ratios observed from routine use of the single base extension chemistry of the 34-plex test. Finally, the genotyping of the widely used DNA profiling Standard Reference Material samples plus other control DNAs completes the audit of the 34-plex assay to allow forensic practitioners to apply this test more readily in their own laboratories. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Refractive index sensing in the visible/NIR spectrum using silicon nanopillar arrays.

    PubMed

    Visser, D; Choudhury, B Dev; Krasovska, I; Anand, S

    2017-05-29

    Si nanopillar (NP) arrays are investigated as refractive index sensors in the visible/NIR wavelength range, suitable for Si photodetector responsivity. The NP arrays are fabricated by nanoimprint lithography and dry etching, and coated with thin dielectric layers. The reflectivity peaks obtained by finite-difference time-domain (FDTD) simulations show a linear shift with coating layer thickness. At 730 nm wavelength, sensitivities of ~0.3 and ~0.9 nm/nm of SiO 2 and Si 3 N 4 , respectively, are obtained; and the optical thicknesses of the deposited surface coatings are determined by comparing the experimental and simulated data. The results show that NP arrays can be used for sensing surface bio-layers. The proposed method could be useful to determine the optical thickness of surface coatings, conformal and non-conformal, in NP-based optical devices.

  12. Growing swimming algae for bioenergy

    NASA Astrophysics Data System (ADS)

    Croze, Ottavio

    Biofuel production from photosynthetic microalgae is not commercially viable due to high processing costs. New engineering and biological solutions are being sought to reduce these costs by increasing processing efficiency (productivity per energy input). Important physics, however, is ignored. For example, the fluid dynamics of algal suspensions in photobioreactors (ponds or tube arrays) is non-trivial, particularly if the algae swim. Cell reorientation by passive viscous and gravitational torques (gyrotaxis) or active reorientation by light (phototaxis) cause swimming algae in suspension to structure in flows, even turbulent ones. This impacts the distribution and dispersion of swimmers, with significant consequences for photobioreactor operation and design. In this talk, I will describe a theory that predicts swimmer dispersion in laminar pipe flows. I will then then present experimental tests of the theory, as well as new results on the circadian suspension dynamics of the algaChlamydomonas reinhardtii in lab-scale photobioreactors. Finally, I will briefly consider the implications of our work, and related active matter research, for improving algal bioprocessing efficiency. Winton Programme for the Physics of Sustainability.

  13. Towards Integrated Marmara Strong Motion Network

    NASA Astrophysics Data System (ADS)

    Durukal, E.; Erdik, M.; Safak, E.; Ansal, A.; Ozel, O.; Alcik, H.; Mert, A.; Kafadar, N.; Korkmaz, A.; Kurtulus, A.

    2009-04-01

    Istanbul has a 65% chance of having a magnitude 7 or above earthquake within the next 30 years. As part of the preparations for the future earthquake, strong motion networks have been installed in and around Istanbul. The Marmara Strong Motion Network, operated by the Department of Earthquake Engineering of Kandilli Observatory and Earthquake Research Institute, encompasses permanent systems outlined below. It is envisaged that the networks will be run by a single entity responsible for technical management and maintanence, as well as for data management, archiving and dissemination through dedicated web-based interfaces. • Istanbul Earthquake Rapid Response and Early Warning System - IERREWS (one hundred 18-bit accelerometers for rapid response; ten 24-bit accelerometers for early warning) • IGDAŞ Gas Shutoff Network (100 accelerometers to be installed in 2010 and integrated with IERREWS) • Structural Monitoring Arrays - Fatih Sultan Mehmet Suspension Bridge (1200m-long suspension bridge across the Bosphorus, five 3-component accelerometers + GPS sensors) - Hagia Sophia Array (1500-year-old historical edifice, 9 accelerometers) - Süleymaniye Mosque Array (450-year-old historical edifice,9 accelerometers) - Fatih Mosque Array (237-year-old historical edifice, 9 accelerometers) - Kanyon Building Array (high-rise office building, 5 accelerometers) - Isbank Tower Array (high-rise office building, 5 accelerometers) - ENRON Array (power generation facility, 4 acelerometers) - Mihrimah Sultan Mosque Array (450-year-old historical edifice,9 accelerometers + tiltmeters, to be installed in 2009) - Sultanahmet Mosque Array, (390-year-old historical edifice, 9 accelerometers + tiltmeters, to be installed in 2009) • Special Arrays - Atakoy Vertical Array (four 3-component accelerometers at 25, 50, 75, and 150 m depths) - Marmara Tube Tunnel (1400 m long submerged tunnel, 128 ch. accelerometric data, 24 ch. strain data, to be installed in 2010) - Air-Force Academy Array (72 ch. dense accelerometric array to be installed in 2010) - Gemlik Array (a dense basin array of 8 stations, to be installed in 2010) The objectives of these systems and networks are: (1) to produce rapid earthquake intensity, damage and loss assessment information after an earthquake (in the case of IERREWS), (2) to monitor conditions of structural systems, (3) to develop real-time data processing, analysis, and damage detection and location tools (in the case of structural networks) after an extreme event, (4) to assess spatial properties of strong ground motion and ground strain, and to characterise basin response (in the case of special arrays), (5) to investigate site response and wave propagation (in the case of vertical array). Ground motion data obtained from these strong motion networks have and are being used for investigations of attenuation, spatial variation (coherence), simulation benchmarking, source modeling, site response, seismic microzonation, system identification and structural model verification and structural health control. In addition to the systems and networks outlined above there are two temporary networks: KIMNET - a dense urban noise and microtremor network consisting of 50 broadband stations expected to be operational in mid 2009, and SOSEWIN - a 20-station, self-organizing structural integrated array at Ataköy in Istanbul.

  14. Effects of dietary supplementation with an organic source of selenium on characteristics of semen quality and in vitro fertility in boars.

    PubMed

    Speight, S M; Estienne, M J; Harper, A F; Crawford, R J; Knight, J W; Whitaker, B D

    2012-03-01

    Semen characteristics in boars fed organic or inorganic sources of Se were assessed in 3 experiments. Crossbred boars were randomly assigned at weaning to 1 of 3 dietary treatments: I) basal diets with no supplemental Se (control), II) basal diets with 0.3 mg/kg of supplemental Se from an organic source (Sel-Plex, Alltech Inc., Nicholasville, KY), and III) basal diets supplemented with 0.3 mg/kg of supplemental Se from sodium selenite (Premium Selenium 270, North American Nutrition Co. Inc., Lewisburg, OH). For Exp. 1, semen was collected from boars (n = 10/dietary treatment) on 5 consecutive days at 15 mo of age. Effects of treatment × day were detected for the proportions of progressively motile (P = 0.02) and rapidly moving (P = 0.03) spermatozoa, and measures of sperm velocity, including path velocity of the smoothed cell path (P = 0.05) and average velocity measured in a straight line from the beginning to the end of the track (P = 0.05). Negative effects of day of semen collection on sperm motility were least pronounced in boars fed Sel-Plex. Experiment 2 was conducted when boars were 17 mo of age, and semen was collected (n = 10 boars/dietary treatment), diluted in commercially available extenders, and stored at 18°C for 9 d. Effects of treatment × day were detected for percentages of motile (P = 0.01) and static (P = 0.01) spermatozoa, amplitude of lateral head displacement (P = 0.02), frequency with which the sperm track crossed the sperm path (P = 0.04), straightness (P = 0.01), and average size of all sperm heads (P = 0.03). In general, sperm cells from boars fed Sel-Plex were better able to maintain motility during liquid storage compared with boars fed sodium selenite. For Exp. 3, semen was collected from boars (n = 6/dietary treatment) at 23 mo of age, and spermatozoa were evaluated at d 1 and 8 after semen collection using in vitro fertilization procedures. There was a tendency for an effect (P = 0.11) of dietary treatment on fertilization rate with Sel-Plex-fed boars having the greatest value (70.7%). The results of this study suggest that there are positive effects of dietary supplementation with Sel-Plex on boar semen characteristics and that organic Se supplementation may help ameliorate the negative effects of semen storage on characteristics of sperm motility.

  15. Targeted sequencing of clade-specific markers from skin microbiomes for forensic human identification.

    PubMed

    Schmedes, Sarah E; Woerner, August E; Novroski, Nicole M M; Wendt, Frank R; King, Jonathan L; Stephens, Kathryn M; Budowle, Bruce

    2018-01-01

    The human skin microbiome is comprised of diverse communities of bacterial, eukaryotic, and viral taxa and contributes millions of additional genes to the repertoire of human genes, affecting human metabolism and immune response. Numerous genetic and environmental factors influence the microbiome composition and as such contribute to individual-specific microbial signatures which may be exploited for forensic applications. Previous studies have demonstrated the potential to associate skin microbial profiles collected from touched items to their individual owner, mainly using unsupervised methods from samples collected over short time intervals. Those studies utilize either targeted 16S rRNA or shotgun metagenomic sequencing to characterize skin microbiomes; however, these approaches have limited species and strain resolution and susceptibility to stochastic effects, respectively. Clade-specific markers from the skin microbiome, using supervised learning, can predict individual identity using skin microbiomes from their respective donors with high accuracy. In this study the hidSkinPlex is presented, a novel targeted sequencing method using skin microbiome markers developed for human identification. The hidSkinPlex (comprised of 286 bacterial (and phage) family-, genus-, species-, and subspecies-level markers), initially was evaluated on three bacterial control samples represented in the panel (i.e., Propionibacterium acnes, Propionibacterium granulosum, and Rothia dentocariosa) to assess the performance of the multiplex. The hidSkinPlex was further evaluated for prediction purposes. The hidSkinPlex markers were used to attribute skin microbiomes collected from eight individuals from three body sites (i.e., foot (Fb), hand (Hp) and manubrium (Mb)) to their host donor. Supervised learning, specifically regularized multinomial logistic regression and 1-nearest-neighbor classification were used to classify skin microbiomes to their hosts with up to 92% (Fb), 96% (Mb), and 100% (Hp) accuracy. All samples (n=72) regardless of body site origin were correctly classified with up to 94% accuracy, and body site origin could be predicted with up to 86% accuracy. Finally, human short tandem repeat and single-nucleotide polymorphism profiles were generated from skin swab extracts from a single subject to highlight the potential to use microbiome profiling in conjunction with low-biomass samples. The hidSkinPlex is a novel targeted enrichment approach to profile skin microbiomes for human forensic identification purposes and provides a method to further characterize the utility of skin microflora for human identification in future studies, such as the stability and diversity of the personal skin microbiome. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Local and Systemic Inflammatory Responses to Experimentally Induced Gingivitis

    PubMed Central

    Leishman, Shaneen J.; Seymour, Gregory J.; Ford, Pauline J.

    2013-01-01

    This study profiled the local and systemic inflammatory responses to experimentally induced gingivitis. Eight females participated in a 21-day experimental gingivitis model followed by a 14-day resolution phase. Bleeding on probing and plaque index scores were assessed before, during, and after resolution of gingival inflammation, and samples of saliva, GCF, and plasma were collected. Samples were assessed for biomarkers of inflammation using the BioPlex platform and ELISA. There were no significant changes in GCF levels of cytokines during the experimental phase; however, individual variability in cytokine profiles was noted. During resolution, mean GCF levels of IL-2, IL-6, and TNF-α decreased and were significantly lower than baseline levels (P = 0.003, P = 0.025, and P = 0.007, resp.). Furthermore, changes in GCF levels of IL-2, IL-6, and TNF-α during resolution correlated with changes in plaque index scores (r = 0.88, P = 0.004; r = 0.72, P = 0.042; r = 0.79, P = 0.019, resp.). Plasma levels of sICAM-1 increased significantly during the experimental phase (P = 0.002) and remained elevated and significantly higher than baseline levels during resolution (P < 0.001). These results support the concept that gingivitis adds to the systemic inflammatory burden of an individual. PMID:24227893

  17. Local and systemic inflammatory responses to experimentally induced gingivitis.

    PubMed

    Leishman, Shaneen J; Seymour, Gregory J; Ford, Pauline J

    2013-01-01

    This study profiled the local and systemic inflammatory responses to experimentally induced gingivitis. Eight females participated in a 21-day experimental gingivitis model followed by a 14-day resolution phase. Bleeding on probing and plaque index scores were assessed before, during, and after resolution of gingival inflammation, and samples of saliva, GCF, and plasma were collected. Samples were assessed for biomarkers of inflammation using the BioPlex platform and ELISA. There were no significant changes in GCF levels of cytokines during the experimental phase; however, individual variability in cytokine profiles was noted. During resolution, mean GCF levels of IL-2, IL-6, and TNF-α decreased and were significantly lower than baseline levels (P = 0.003, P = 0.025, and P = 0.007, resp.). Furthermore, changes in GCF levels of IL-2, IL-6, and TNF-α during resolution correlated with changes in plaque index scores (r = 0.88, P = 0.004; r = 0.72, P = 0.042; r = 0.79, P = 0.019, resp.). Plasma levels of sICAM-1 increased significantly during the experimental phase (P = 0.002) and remained elevated and significantly higher than baseline levels during resolution (P < 0.001). These results support the concept that gingivitis adds to the systemic inflammatory burden of an individual.

  18. Comparative effects between electronic and cigarette smoke in human keratinocytes and epithelial lung cells.

    PubMed

    Cervellati, F; Muresan, X M; Sticozzi, C; Gambari, R; Montagner, G; Forman, H J; Torricelli, C; Maioli, E; Valacchi, G

    2014-08-01

    Information about the harmful effects of vaping is sparse and inconsistent, therefore, since the use of electronic cigarettes (e-CIGs) has become increasingly popular as a tool to limit tobacco smoking, it is urgent to establish the toxicity of the commercial e-CIGs. Skin (HaCaT) and lung (A549) cells, the main targets of cigarette smoke (CS), were exposed to e-CIG vapor and CS using an in vitro system. The cytotoxic effect of the exposure was analyzed in both cell types by ultrastructural morphology, Trypan Blue exclusion test and LDH assay. In addition, pro-inflammatory cytokines were measured by the Bio-Plex assay. The cytotoxic components of e-CIG were restrained to the flavoring compound and, to a lesser extent, to nicotine although their effects were less harmful to that of CS. Humectants alone exhibited no cytotoxicity but induced the release of cytokines and pro-inflammatory mediators. Based on our results, we can state that exposure to e-CIG vapors results in far less toxic than exposure to CS. In fact, besides the deleterious effect of flavor and nicotine, even the humectants alone are able to evocate cytokines release. This study will hopefully promote the development of safer e-CIGs to help people quit smoking. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Correlation of interleukin-6 and monocyte chemotactic protein-1 concentrations with crescent formation and myeloperoxidase-specific anti-neutrophil cytoplasmic antibody titer in SCG/Kj mice by treatment with anti-interleukin-6 receptor antibody or mizoribine.

    PubMed

    Nagao, Tomokazu; Kusunoki, Reina; Iwamura, Chiaki; Kobayashi, Shigeto; Yumura, Wako; Kameoka, Yosuke; Nakayama, Toshinori; Suzuki, Kazuo

    2013-09-01

    Myeloperoxidase-specific anti-neutrophil cytoplasmic antibody (MPO-ANCA) is associated with rapidly progressive glomerulonephritis (RPGN) and glomerular crescent formation. Pathogenic factors in RPGN were analyzed by using SCG/Kj mice, which spontaneously develop MPO-ANCA-associated RPGN. The serum concentration of soluble IL-6R was determined by using ELISA and those of another 23 cytokines and chemokines by Bio-Plex analysis. Sections of frozen kidney tissue were examined by fluorescence microscopy and the CD3(+) B220(+) T cell subset in the spleen determined by a flow cytometry. Concentrations of IL-6 and monocyte chemotactic protein-1 were significantly correlated with the percentages of crescent formation. Anti-IL-6R antibody, which has been effective in patients with rheumatoid arthritis, was administered to SCG/Kj mice to elucidate the role of IL-6 in the development of RPGN. MPO-ANCA titers decreased after administration of anti-IL-6R antibody, but not titers of mizoribine, which is effective in Kawasaki disease model mice. These results suggest that IL-6-mediated signaling is involved in the production of MPO-ANCA. © 2013 The Societies and Wiley Publishing Asia Pty Ltd.

  20. Evolution from MEMS-based Linear Drives to Bio-based Nano Drives

    NASA Astrophysics Data System (ADS)

    Fujita, Hiroyuki

    The successful extension of semiconductor technology to fabricate mechanical parts of the sizes from 10 to 100 micrometers opened wide ranges of possibilities for micromechanical devices and systems. The fabrication technique is called micromachining. Micromachining processes are based on silicon integrated circuits (IC) technology and used to build three-dimensional structures and movable parts by the combination of lithography, etching, film deposition, and wafer bonding. Microactuators are the key devices allowing MEMS to perform physical functions. Some of them are driven by electric, magnetic, and fluidic forces. Some others utilize actuator materials including piezoelectric (PZT, ZnO, quartz) and magnetostrictive materials (TbFe), shape memory alloy (TiNi) and bio molecular motors. This paper deals with the development of MEMS based microactuators, especially linear drives, following my own research experience. They include an electrostatic actuator, a superconductive levitated actuator, arrayed actuators, and a bio-motor-driven actuator.

  1. Overcoming the brittleness of glass through bio-inspiration and micro-architecture.

    PubMed

    Mirkhalaf, M; Dastjerdi, A Khayer; Barthelat, F

    2014-01-01

    Highly mineralized natural materials such as teeth or mollusk shells boast unusual combinations of stiffness, strength and toughness currently unmatched by engineering materials. While high mineral contents provide stiffness and hardness, these materials also contain weaker interfaces with intricate architectures, which can channel propagating cracks into toughening configurations. Here we report the implementation of these features into glass, using a laser engraving technique. Three-dimensional arrays of laser-generated microcracks can deflect and guide larger incoming cracks, following the concept of 'stamp holes'. Jigsaw-like interfaces, infiltrated with polyurethane, furthermore channel cracks into interlocking configurations and pullout mechanisms, significantly enhancing energy dissipation and toughness. Compared with standard glass, which has no microstructure and is brittle, our bio-inspired glass displays built-in mechanisms that make it more deformable and 200 times tougher. This bio-inspired approach, based on carefully architectured interfaces, provides a new pathway to toughening glasses, ceramics or other hard and brittle materials.

  2. The fabrication of subwavelength anti-reflective nanostructures using a bio-template

    NASA Astrophysics Data System (ADS)

    Xie, Guoyong; Zhang, Guoming; Lin, Feng; Zhang, Jin; Liu, Zhongfan; Mu, Shichen

    2008-03-01

    This paper describes a paradigm, a simple, low-cost and conventional approach to the fabrication of large-area subwavelength anti-reflective nanostructures on films directly with a bio-template. Specifically, the nano-nipple arrays on the surface of cicada wings have been precisely replicated to a PMMA (polymethyl methacrylate) film with high reproducibility by a technique of replica molding, which mainly involves two processes: one is that a negative Au mold is prepared directly from the bio-template of the cicada wing by thermal deposition; the other is that the Au mold is used to obtain the replica of the nanostructures on the original cicada wing by casting polymer. The reflectance spectra measurement shows that the replicated PMMA film can considerably reduce reflectivity at its surface over a large wavelength range from 250 to 800 nm, indicating that the anti-reflective property has also been inherited by the PMMA film.

  3. Overcoming the brittleness of glass through bio-inspiration and micro-architecture

    NASA Astrophysics Data System (ADS)

    Mirkhalaf, M.; Dastjerdi, A. Khayer; Barthelat, F.

    2014-01-01

    Highly mineralized natural materials such as teeth or mollusk shells boast unusual combinations of stiffness, strength and toughness currently unmatched by engineering materials. While high mineral contents provide stiffness and hardness, these materials also contain weaker interfaces with intricate architectures, which can channel propagating cracks into toughening configurations. Here we report the implementation of these features into glass, using a laser engraving technique. Three-dimensional arrays of laser-generated microcracks can deflect and guide larger incoming cracks, following the concept of ‘stamp holes’. Jigsaw-like interfaces, infiltrated with polyurethane, furthermore channel cracks into interlocking configurations and pullout mechanisms, significantly enhancing energy dissipation and toughness. Compared with standard glass, which has no microstructure and is brittle, our bio-inspired glass displays built-in mechanisms that make it more deformable and 200 times tougher. This bio-inspired approach, based on carefully architectured interfaces, provides a new pathway to toughening glasses, ceramics or other hard and brittle materials.

  4. Analogue solution for electrical capacity of membrane covered square cylinders in square array at high concentration.

    PubMed

    Cole, K S

    1975-12-01

    Analytical solutions of Laplace equations have given the electrical characteristics of membranes and interiors of spherical, ellipsoidal, and cylindrical cells in suspensions and tissues from impedance measurements, but the underlying assumptions may be invalid above 50% volume concentrations. However, resistance measurements on several nonconducting, close-packing forms in two and three dimensions closely predicted volume concentrations up to 100% by equations derived from Maxwell and Rayleigh. Calculations of membrane capacities of cells in suspensions and tissues from extensions of theory, as developed by Fricke and by Cole, have been useful but of unknown validity at high concentrations. A resistor analogue has been used to solve the finite difference approximation to the Laplace equation for the resistance and capacity of a square array of square cylindrical cells with surface capacity. An 11 x 11 array of resistors, simulating a quarter of the unit structure, was separated into intra- and extra-cellular regions by rows of capacitors corresponding to surface membrane areas from 3 x 3 to 11 x 11 or 7.5% to 100%. The extended Rayleigh equation predicted the cell concentrations and membrane capacities to within a few percent from boundary resistance and capacity measurements at low frequencies. This single example suggests that analytical solutions for other, similar two- and three-dimensional problems may be approximated up to near 100% concentrations and that there may be analytical justifications for such analogue solutions of Laplace equations.

  5. Mechanochemistry of Chitosan-Coated Zinc Sulfide (ZnS) Nanocrystals for Bio-imaging Applications.

    PubMed

    Bujňáková, Zdenka; Dutková, Erika; Kello, Martin; Mojžiš, Ján; Baláž, Matej; Baláž, Peter; Shpotyuk, Oleh

    2017-12-01

    The ZnS nanocrystals were prepared in chitosan solution (0.1 wt.%) using a wet ultra-fine milling. The obtained suspension was stable and reached high value of zeta potential (+57 mV). The changes in FTIR spectrum confirmed the successful surface coating of ZnS nanoparticles by chitosan. The prepared ZnS nanocrystals possessed interesting optical properties verified in vitro. Four cancer cells were selected (CaCo-2, HCT116, HeLa, and MCF-7), and after their treatment with the nanosuspension, the distribution of ZnS in the cells was studied using a fluorescence microscope. The particles were clearly seen; they passed through the cell membrane and accumulated in cytosol. The biological activity of the cells was not influenced by nanoparticles, they did not cause cell death, and only the granularity of cells was increased as a consequence of cellular uptake. These results confirm the potential of ZnS nanocrystals using in bio-imaging applications.

  6. Mechanochemistry of Chitosan-Coated Zinc Sulfide (ZnS) Nanocrystals for Bio-imaging Applications

    NASA Astrophysics Data System (ADS)

    Bujňáková, Zdenka; Dutková, Erika; Kello, Martin; Mojžiš, Ján; Baláž, Matej; Baláž, Peter; Shpotyuk, Oleh

    2017-05-01

    The ZnS nanocrystals were prepared in chitosan solution (0.1 wt.%) using a wet ultra-fine milling. The obtained suspension was stable and reached high value of zeta potential (+57 mV). The changes in FTIR spectrum confirmed the successful surface coating of ZnS nanoparticles by chitosan. The prepared ZnS nanocrystals possessed interesting optical properties verified in vitro. Four cancer cells were selected (CaCo-2, HCT116, HeLa, and MCF-7), and after their treatment with the nanosuspension, the distribution of ZnS in the cells was studied using a fluorescence microscope. The particles were clearly seen; they passed through the cell membrane and accumulated in cytosol. The biological activity of the cells was not influenced by nanoparticles, they did not cause cell death, and only the granularity of cells was increased as a consequence of cellular uptake. These results confirm the potential of ZnS nanocrystals using in bio-imaging applications.

  7. Bio-inactivation of human malignant cells through highly responsive diluted colloidal suspension of functionalized magnetic iron oxide nanoparticles

    NASA Astrophysics Data System (ADS)

    Ferreira, Roberta V.; Silva-Caldeira, Priscila P.; Pereira-Maia, Elene C.; Fabris, José D.; Cavalcante, Luis Carlos D.; Ardisson, José D.; Domingues, Rosana Z.

    2016-04-01

    Magnetic fluids, more specifically aqueous colloidal suspensions containing certain magnetic nanoparticles (MNPs), have recently been gaining special interest due to their potential use in clinical treatments of cancerous formations in mammalians. The technological application arises mainly from their hyperthermic behavior, which means that the nanoparticles dissipate heat upon being exposed to an alternating magnetic field (AMF). If the temperature is raised to slightly above 43 °C, cancer cells are functionally inactivated or killed; however, normal cells tend to survive under those same conditions, entirely maintaining their bioactivity. Recent in vitro studies have revealed that under simultaneous exposure to an AMF and magnetic nanoparticles, certain lines of cancer cells are bio-inactivated even without experiencing a significant temperature increase. This non-thermal effect is cell specific, indicating that MNPs, under alternating magnetic fields, may effectively kill cancer cells under conditions that were previously thought to be implausible, considering that the temperature does not increase more than 5 °C, which is also true in cases for which the concentration of MNPs is too low. To experimentally test for this effect, this study focused on the feasibility of inducing K562 cell death using an AMF and aqueous suspensions containing very low concentrations of MNPs. The assay was designed for a ferrofluid containing magnetite nanoparticles, which were obtained through the co-precipitation method and were functionalized with citric acid; the particles had an average diameter of 10 ± 2 nm and a mean hydrodynamic diameter of approximately 40 nm. Experiments were first performed to test for the ability of the ferrofluid to release heat under an AMF. The results show that for concentrations ranging from 2.5 to 1.0 × 103 mg L-1, the maximum temperature increase was actually less than 2 °C. However, the in vitro test results from K562 cells and suspensions containing these MNPs at concentrations varying within a narrower range from 2.5 to 10 mg L-1, typically under an AMF of 15 kA m-1 at 356 kHz, indicate efficient cytotoxic activity against malignant cells and inhibition of cell growth, even at very low hyperthermally induced temperature increases. The IC50 value varied with time, reaching 3.5 mg L-1 after 10 min under the AMF. Our results effectively demonstrate new prospective uses for such nanoparticles in advanced medical practices in oncology.

  8. Enhanced vibrational spectroscopy, intracellular refractive indexing for label-free biosensing and bioimaging by multiband plasmonic-antenna array.

    PubMed

    Chen, Cheng-Kuang; Chang, Ming-Hsuan; Wu, Hsieh-Ting; Lee, Yao-Chang; Yen, Ta-Jen

    2014-10-15

    In this study, we report a multiband plasmonic-antenna array that bridges optical biosensing and intracellular bioimaging without requiring a labeling process or coupler. First, a compact plasmonic-antenna array is designed exhibiting a bandwidth of several octaves for use in both multi-band plasmonic resonance-enhanced vibrational spectroscopy and refractive index probing. Second, a single-element plasmonic antenna can be used as a multifunctional sensing pixel that enables mapping the distribution of targets in thin films and biological specimens by enhancing the signals of vibrational signatures and sensing the refractive index contrast. Finally, using the fabricated plasmonic-antenna array yielded reliable intracellular observation was demonstrated from the vibrational signatures and intracellular refractive index contrast requiring neither labeling nor a coupler. These unique features enable the plasmonic-antenna array to function in a label-free manner, facilitating bio-sensing and imaging development. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Phospholipid arrays on porous polymer coatings generated by micro-contact spotting

    PubMed Central

    de Freitas, Monica; Tröster, Lea-Marie; Jochum, Tobias; Levkin, Pavel A; Hirtz, Michael; Fuchs, Harald

    2017-01-01

    Nanoporous poly(2-hydroxyethyl methacrylate-co-ethylene dimethacrylate) (HEMA-EDMA) is used as a 3D mesh for spotting lipid arrays. Its porous structure is an ideal matrix for lipid ink to infiltrate, resulting in higher fluorescent signal intensity as compared to similar arrays on strictly 2D substrates like glass. The embedded lipid arrays show high stability against washing steps, while still being accessible for protein and antibody binding. To characterize binding to polymer-embedded lipids we have applied Streptavidin as well as biologically important biotinylated androgen receptor binding onto 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-(cap biotinyl) (Biotinyl Cap PE) and anti-DNP IgE recognition of 2,4-dinitrophenyl[1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-[6-[(2,4-dinitrophenyl)amino]hexanoyl] (DNP)] antigen. This approach adds lipid arrays to the range of HEMA polymer applications and makes this solid substrate a very attractive platform for a variety of bio-applications. PMID:28487815

  10. Towards an implantable bio-sensor platform for continuous real-time monitoring of anti-epileptic drugs.

    PubMed

    Hammoud, Abbas; Chamseddine, Ahmad; Nguyen, Dang K; Sawan, Mohamad

    2016-08-01

    The need of continuous real-time monitoring device for in-vivo drug level detection has been widely articulated lately. Such monitoring could guide drug posology and timing of intake, detect low or high drug levels, in order to take adequate measures, and give clinicians a valuable window into patients' health and their response to therapeutics. This paper presents a novel implantable bio-sensor based on impedance measurement capable of continuously monitoring various antiepileptic drug levels. This portable point-of-care microsystem replaces large and stationary conventional macrosystems, and is a one of a kind system designed with an array of electrodes to monitor various anti-epileptic drugs rather than one drug. The micro-system consists of (i) the front-end circuit including an inductive coil to receive energy from an external base station, and to exchange data with the latter; (ii) the power management block; (iii) the readout and control block; and (iv) the biosensor array. The electrical circuitry was designed using the 0.18-um CMOS process technology intended to be miniature and consume ultra-low power.

  11. Chromatic Modulator for High Resolution CCD or APS Devices

    NASA Technical Reports Server (NTRS)

    Hartley, Frank T. (Inventor); Hull, Anthony B. (Inventor)

    2003-01-01

    A system for providing high-resolution color separation in electronic imaging. Comb drives controllably oscillate a red-green-blue (RGB) color strip filter system (or otherwise) over an electronic imaging system such as a charge-coupled device (CCD) or active pixel sensor (APS). The color filter is modulated over the imaging array at a rate three or more times the frame rate of the imaging array. In so doing, the underlying active imaging elements are then able to detect separate color-separated images, which are then combined to provide a color-accurate frame which is then recorded as the representation of the recorded image. High pixel resolution is maintained. Registration is obtained between the color strip filter and the underlying imaging array through the use of electrostatic comb drives in conjunction with a spring suspension system.

  12. Comparison of Cepheid Xpert Flu/RSV XC and BioFire FilmArray for Detection of Influenza A, Influenza B, and Respiratory Syncytial Virus.

    PubMed

    Wahrenbrock, Mark G; Matushek, Scott; Boonlayangoor, Sue; Tesic, Vera; Beavis, Kathleen G; Charnot-Katsikas, Angella

    2016-07-01

    The Xpert Flu/RSV XC was compared to the FilmArray respiratory panel for detection of influenza (Flu) A, Flu B, and respiratory syncytial virus (RSV), using 128 nasopharyngeal swabs. Positive agreements were 100% for Flu A and RSV and 92.3% for Flu B. The Xpert may be useful in clinical situations when extensive testing is not required and may serve an important role in laboratories already performing broader respiratory panel testing. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  13. Surface-Micromachined Planar Arrays of Thermopiles

    NASA Technical Reports Server (NTRS)

    Foote, Marc C.

    2003-01-01

    Planar two-dimensional arrays of thermopiles intended for use as thermal-imaging detectors are to be fabricated by a process that includes surface micromachining. These thermopile arrays are designed to perform better than do prior two-dimensional thermopile arrays. The lower performance of prior two-dimensional thermopile arrays is attributed to the following causes: The thermopiles are made from low-performance thermoelectric materials. The devices contain dielectric supporting structures, the thermal conductances of which give rise to parasitic losses of heat from detectors to substrates. The bulk-micromachining processes sometimes used to remove substrate material under the pixels, making it difficult to incorporate low-noise readout electronic circuitry. The thermoelectric lines are on the same level as the infrared absorbers, thereby reducing fill factor. The improved pixel design of a thermopile array of the type under development is expected to afford enhanced performance by virtue of the following combination of features: Surface-micromachined detectors are thermally isolated through suspension above readout circuitry. The thermopiles are made of such high-performance thermoelectric materials as Bi-Te and Bi-Sb-Te alloys. Pixel structures are supported only by the thermoelectric materials: there are no supporting dielectric structures that could leak heat by conduction to the substrate.

  14. Bio-microfluidics: biomaterials and biomimetic designs.

    PubMed

    Domachuk, Peter; Tsioris, Konstantinos; Omenetto, Fiorenzo G; Kaplan, David L

    2010-01-12

    Bio-microfluidics applies biomaterials and biologically inspired structural designs (biomimetics) to microfluidic devices. Microfluidics, the techniques for constraining fluids on the micrometer and sub-micrometer scale, offer applications ranging from lab-on-a-chip to optofluidics. Despite this wealth of applications, the design of typical microfluidic devices imparts relatively simple, laminar behavior on fluids and is realized using materials and techniques from silicon planar fabrication. On the other hand, highly complex microfluidic behavior is commonplace in nature, where fluids with nonlinear rheology flow through chaotic vasculature composed from a range of biopolymers. In this Review, the current state of bio-microfluidic materials, designs and applications are examined. Biopolymers enable bio-microfluidic devices with versatile functionalization chemistries, flexibility in fabrication, and biocompatibility in vitro and in vivo. Polymeric materials such as alginate, collagen, chitosan, and silk are being explored as bulk and film materials for bio-microfluidics. Hydrogels offer options for mechanically functional devices for microfluidic systems such as self-regulating valves, microlens arrays and drug release systems, vital for integrated bio-microfluidic devices. These devices including growth factor gradients to study cell responses, blood analysis, biomimetic capillary designs, and blood vessel tissue culture systems, as some recent examples of inroads in the field that should lead the way in a new generation of microfluidic devices for bio-related needs and applications. Perhaps one of the most intriguing directions for the future will be fully implantable microfluidic devices that will also integrate with existing vasculature and slowly degrade to fully recapitulate native tissue structure and function, yet serve critical interim functions, such as tissue maintenance, drug release, mechanical support, and cell delivery.

  15. Comparison of single cell sequencing data between two whole genome amplification methods on two sequencing platforms.

    PubMed

    Chen, DaYang; Zhen, HeFu; Qiu, Yong; Liu, Ping; Zeng, Peng; Xia, Jun; Shi, QianYu; Xie, Lin; Zhu, Zhu; Gao, Ya; Huang, GuoDong; Wang, Jian; Yang, HuanMing; Chen, Fang

    2018-03-21

    Research based on a strategy of single-cell low-coverage whole genome sequencing (SLWGS) has enabled better reproducibility and accuracy for detection of copy number variations (CNVs). The whole genome amplification (WGA) method and sequencing platform are critical factors for successful SLWGS (<0.1 × coverage). In this study, we compared single cell and multiple cells sequencing data produced by the HiSeq2000 and Ion Proton platforms using two WGA kits and then comprehensively evaluated the GC-bias, reproducibility, uniformity and CNV detection among different experimental combinations. Our analysis demonstrated that the PicoPLEX WGA Kit resulted in higher reproducibility, lower sequencing error frequency but more GC-bias than the GenomePlex Single Cell WGA Kit (WGA4 kit) independent of the cell number on the HiSeq2000 platform. While on the Ion Proton platform, the WGA4 kit (both single cell and multiple cells) had higher uniformity and less GC-bias but lower reproducibility than those of the PicoPLEX WGA Kit. Moreover, on these two sequencing platforms, depending on cell number, the performance of the two WGA kits was different for both sensitivity and specificity on CNV detection. The results can help researchers who plan to use SLWGS on single or multiple cells to select appropriate experimental conditions for their applications.

  16. Clinical Sensitivity of Cystic Fibrosis Mutation Panels in a Diverse Population.

    PubMed

    Hughes, Erin E; Stevens, Colleen F; Saavedra-Matiz, Carlos A; Tavakoli, Norma P; Krein, Lea M; Parker, April; Zhang, Zhen; Maloney, Breanne; Vogel, Beth; DeCelie-Germana, Joan; Kier, Catherine; Anbar, Ran D; Berdella, Maria N; Comber, Paul G; Dozor, Allen J; Goetz, Danielle M; Guida, Louis; Kattan, Meyer; Ting, Andrew; Voter, Karen Z; van Roey, Patrick; Caggana, Michele; Kay, Denise M

    2016-02-01

    Infants are screened for cystic fibrosis (CF) in New York State (NYS) using an IRT-DNA algorithm. The purpose of this study was to validate and assess clinical validity of the US FDA-cleared Illumina MiSeqDx CF 139-Variant Assay (139-VA) in the diverse NYS CF population. The study included 439 infants with CF identified via newborn screening (NBS) from 2002 to 2012. All had been screened using the Abbott Molecular CF Genotyping Assay or the Hologic InPlex CF Molecular Test. All with CF and zero or one mutation were tested using the 139-VA. DNA extracted from dried blood spots was reliably and accurately genotyped using the 139-VA. Sixty-three additional mutations were identified. Clinical sensitivity of three panels ranged from 76.2% (23 mutations recommended for screening by ACMG/ACOG) to 79.7% (current NYS 39-mutation InPlex panel), up to 86.0% for the 139-VA. For all, sensitivity was highest in Whites and lowest in the Black population. Although the sample size was small, there was a nearly 20% increase in sensitivity for the Black CF population using the 139-VA (68.2%) over the ACMG/ACOG and InPlex panels (both 50.0%). Overall, the 139-VA is more sensitive than other commercially available panels, and could be considered for NBS, clinical, or research laboratories conducting CF screening. © 2015 WILEY PERIODICALS, INC.

  17. Ultraviolet light emitting diodes and bio-aerosol sensing

    NASA Astrophysics Data System (ADS)

    Davitt, Kristina M.

    Recent interest in compact ultraviolet (UV) light emitters has produced advances in material quality and device performance from aluminum-rich alloys of the nitride semiconductor system. The epitaxial growth of device structures from this material poses remarkable challenges, and state-of-the-art in semiconductor UV light sources at wavelengths shorter than 350 nm is currently limited to LEDs. A portion of the work presented in this thesis involves the design and characterization of UV LED structures, with particular focus on sub-300 nm LEDs which have only been demonstrated within the last four years. Emphasis has been placed on the integration of early devices with modest efficiencies and output powers into a practical, fluorescence-based bio-sensing instrument. The quality of AlGaInN and AlGaN-based materials is characterized by way of the performance of 340 nm and 290 nm LEDs respectively. A competitive level of device operation is achieved, although much room remains for improvement in the efficiency of light emission from this material system. A preliminary investigation of 300 nm LEDs grown on bulk AIN shows promising electrical and optical characteristics, and illustrates the numerous advantages that this native substrate offers to the epitaxy of wide bandgap nitride semiconductors. The application of UV LEDs to the field of bio-aerosol sensing is pursued by constructing an on-the-fly fluorescence detection system. A linear array of UV LEDs is designed and implemented, and the capability of test devices to excite native fluorescence from bacterial spores is established. In order to fully capitalize on the reduction in size afforded by LEDs, effort is invested in re-engineering the remaining sensor components. Operation of a prototype system for physically sorting bio-aerosols based on fluorescence spectra acquired in real-time from single airborne particles excited by a UV-LED array is demonstrated using the bio-fluorophores NADH and tryptophan. Sensor performance is shown to be ultimately linked to the material quality of high aluminum fraction nitrides, and is expected to show progress as this field matures.

  18. Sensitive molecular diagnostics using surface-enhanced resonance Raman scattering (SERRS)

    NASA Astrophysics Data System (ADS)

    Faulds, Karen; Graham, Duncan; McKenzie, Fiona; MacRae, Douglas; Ricketts, Alastair; Dougan, Jennifer

    2009-02-01

    Surface enhanced resonance Raman scattering (SERRS) is an analytical technique with several advantages over competitive techniques in terms of improved sensitivity and multiplexing. We have made great progress in the development of SERRS as a quantitative analytical method, in particular for the detection of DNA. SERRS is an extremely sensitive and selective technique which when applied to the detection of labelled DNA sequences allows detection limits to be obtained which rival, and in most cases, are better than fluorescence. Here the conditions are explored which will enable the successful detection of DNA using SERRS. The enhancing surface which is used is crucial and in this case suspensions of nanoparticles were used as they allow quantitative behaviour to be achieved and allow analogous systems to current fluorescence based systems to be made. The aggregation conditions required to obtain SERRS of DNA are crucial and herein we describe the use of spermine as an aggregating agent. The nature of the label which is used, be it fluorescent, positively or negatively charged also effects the SERRS response and these conditions are again explored here. We have clearly demonstrated the ability to identify the components of a mixture of 5 analytes in solution by using two different excitation wavelengths and also of a 6-plex using data analysis techniques. These conditions will allow the use of SERRS for the detection of target DNA in a meaningful diagnostic assay.

  19. Quality control, analysis and secure sharing of Luminex® immunoassay data using the open source LabKey Server platform

    PubMed Central

    2013-01-01

    Background Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists’ capacity to use these immunoassays to evaluate human clinical trials. Results The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose–response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Conclusions Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license. PMID:23631706

  20. Quality control, analysis and secure sharing of Luminex® immunoassay data using the open source LabKey Server platform.

    PubMed

    Eckels, Josh; Nathe, Cory; Nelson, Elizabeth K; Shoemaker, Sara G; Nostrand, Elizabeth Van; Yates, Nicole L; Ashley, Vicki C; Harris, Linda J; Bollenbeck, Mark; Fong, Youyi; Tomaras, Georgia D; Piehler, Britt

    2013-04-30

    Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists' capacity to use these immunoassays to evaluate human clinical trials. The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose-response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license.

  1. Photoluminescence emission from GaAs nanodisks in GaAs/AlGaAs nanopillar arrays fabricated by neutral beam etching

    NASA Astrophysics Data System (ADS)

    Ohori, Daisuke; Fukuyama, Atsuhiko; Sakai, Kentaro; Higo, Akio; Thomas, Cedric; Samukawa, Seiji; Ikari, Tetsuo

    2017-05-01

    GaAs quantum nanodisks (QNDs) in nanopillar (NP) arrays are considered to be an attractive candidate for photonic device applications. We report a damageless fabrication technique that can be used to produce large-area lattice-matched GaAs/AlGaAs heterostructure NP arrays through the use of a bio-template and neutral beam etching. We have successfully realized GaAs QNDs in NPs owing to nanoscale iron oxide masks included in poly(ethylene glycol)-decorated ferritin protein shells. We observed for first time the photoluminescence emission from as-etched GaAs QNDs and confirmed quantum confinement by quantum mechanical calculation. Our methodology is vital for high-efficiency pillar-based optoelectronic devices such as NP laser diodes.

  2. Pixel detectors for use in retina neurophysiology studies

    NASA Astrophysics Data System (ADS)

    Cunningham, W.; Mathieson, K.; Horn, M.; Melone, J.; McEwan, F. A.; Blue, A.; O'Shea, V.; Smith, K. M.; Litke, A.; Chichilnisky, E. J.; Rahman, M.

    2003-08-01

    One area of major inter-disciplinary co-operation is between the particle physics and bio-medical communities. The type of large detector arrays and fast electronics developed in laboratories like CERN are becoming used for a wide range of medical and biological experiments. In the present work fabrication technology developed for producing semiconductor radiation detectors has been applied to produce arrays which have been used in neuro-physiological experiments on retinal tissue. We have exploited UVIII, a low molecular weight resist, that has permitted large area electron beam lithography. This allows the resolution to go below that of conventional photolithography and hence the production of densely packed ˜500 electrode arrays with feature sizes down to below 2 μm. The neural signals from significant areas of the retina may thus be captured.

  3. Optimized design of Yb3+/Er3+-codoped cross-coupled integrated microring resonator arrays

    NASA Astrophysics Data System (ADS)

    Gǎlǎtus, Ramona; Vallés, Juan A.

    2014-09-01

    In this work the analytical model of the scattering response of a highly Yb3+/Er3+-codoped phosphate glass microring resonator array is developed. The microscopic statistical formalism is used to simulate its performance as a wavelengthselective amplifier. The performance of the integrated add-drop filter was investigated based on the signal transfer functions for Through and Drop ports, correlated the with gain coefficient and its dependence on pump power, signal power and Yb3+/Er3+- dopants concentration. In consequence, microring arrays with gain operating in the near infrared spectral range and, in particular, in the 1.5-mm wavelength band (emission band of Er-doped fiber amplifiers and lasers, already used in several bio/chemical sensing tasks) are highly attractive.

  4. Elevated cytokine and chemokine levels in the placenta are associated with in-utero HIV-1 mother-to-child transmission.

    PubMed

    Kumar, Surender B; Rice, Cara E; Milner, Danny A; Ramirez, Nilsa C; Ackerman, William E; Mwapasa, Victor; Turner, Abigail Norris; Kwiek, Jesse J

    2012-03-27

    To determine whether there is an association between cytokine and chemokine levels in plasma isolated from the placenta and HIV-1 mother-to-child transmission (MTCT). We designed a case-control study of HIV-infected, pregnant women enrolled in the Malaria and HIV in Pregnancy cohort. Participants were recruited in Blantyre, Malawi, from 2000 to 2004. Patients were women whose children were HIV-1 DNA-positive at birth (in-utero MTCT) or HIV-1 DNA-negative at birth and HIV-1 DNA-positive at 6 weeks postpartum (intrapartum MTCT); controls were women whose children were HIV-1 DNA-negative both at birth and 6 weeks postpartum. After delivery, blood was isolated from an incision on the basal plate of the placenta. We used a Bio-Plex human cytokine assay (Bio-Rad, Hercules, California USA) to simultaneously quantify 27 cytokines, chemokines and growth factors in placental plasma. HIV-1 RNA copies were quantified with the Roche Amplicor kit. Levels of interleukin (IL) 4, IL-5, IL-6, IL-7, IL-9, eotaxin, IL-1Ra and interferon gamma-induced protein 10 (IP-10) were significantly elevated in placental plasma isolated from cases of in-utero HIV-1 MTCT. In contrast, only granulocyte colony-stimulating factor was elevated in placental plasma isolated from cases of intrapartum MTCT. After adjusting for maternal age, gestational age and peripheral CD4(+) T-cell count, every log(10) increase in placental IP-10 was associated with a three-fold increase in the prevalence of in-utero HIV-1 MTCT. Elevated cytokine and chemokine levels in placental plasma were associated with in-utero and not intrapartum MTCT. IP-10, which is both a T-cell chemokine and potentiator of HIV-replication, was robustly and independently associated with prevalent, in-utero MTCT.

  5. Combining two open source tools for neural computation (BioPatRec and Netlab) improves movement classification for prosthetic control.

    PubMed

    Prahm, Cosima; Eckstein, Korbinian; Ortiz-Catalan, Max; Dorffner, Georg; Kaniusas, Eugenijus; Aszmann, Oskar C

    2016-08-31

    Controlling a myoelectric prosthesis for upper limbs is increasingly challenging for the user as more electrodes and joints become available. Motion classification based on pattern recognition with a multi-electrode array allows multiple joints to be controlled simultaneously. Previous pattern recognition studies are difficult to compare, because individual research groups use their own data sets. To resolve this shortcoming and to facilitate comparisons, open access data sets were analysed using components of BioPatRec and Netlab pattern recognition models. Performances of the artificial neural networks, linear models, and training program components were compared. Evaluation took place within the BioPatRec environment, a Matlab-based open source platform that provides feature extraction, processing and motion classification algorithms for prosthetic control. The algorithms were applied to myoelectric signals for individual and simultaneous classification of movements, with the aim of finding the best performing algorithm and network model. Evaluation criteria included classification accuracy and training time. Results in both the linear and the artificial neural network models demonstrated that Netlab's implementation using scaled conjugate training algorithm reached significantly higher accuracies than BioPatRec. It is concluded that the best movement classification performance would be achieved through integrating Netlab training algorithms in the BioPatRec environment so that future prosthesis training can be shortened and control made more reliable. Netlab was therefore included into the newest release of BioPatRec (v4.0).

  6. Magnetic switching of optical reflectivity in nanomagnet/micromirror suspensions: colloid displays as a potential alternative to liquid crystal displays.

    PubMed

    Bubenhofer, S B; Athanassiou, E K; Grass, R N; Koehler, F M; Rossier, M; Stark, W J

    2009-12-02

    Two-particle colloids containing nanomagnets and microscale mirrors can be prepared from iron oxide nanoparticles, microscale metal flakes and high-density liquids stabilizing the mirror suspension against sedimentation by matching the constituent's density. The free Brownian rotation of the micromirrors can be magnetically controlled through an anisotropic change in impulse transport arising from impacts of the magnetic nanoparticles onto the anisotropic flakes. The resulting rapid mirror orientation allows large changes in light transmission and switchable optical reflectivity. The preparation of a passive display was conceptually demonstrated through colloid confinement in a planar cavity over an array of individually addressable solenoids and resulted in 4 x 4 digit displays with a reaction time of less than 100 ms.

  7. Description of the Large Gap Magnetic Suspension System (LGMSS) ground-based experiment

    NASA Technical Reports Server (NTRS)

    Groom, Nelson J.

    1991-01-01

    A description of the Large Gap Magnetic Suspension System (LGMSS) ground-based experiment is presented. The LGMSS provides five degrees of freedom control of a cylindrical suspended element which is levitated above a floor-mounted array of air core electromagnets. The uncontrolled degree of freedom is rotation about the long axis of the cylinder (roll). Levitation and control forces are produced on a permanent magnet core which is embedded in the cylinder. The cylinder also contains light emitting diodes (LEDs), assorted electrons, and a power supply. The LEDs provide active targets for an optical position measurement system which is being developed in-house at the Langley Research Center. The optical position measurement system will provide six degrees of freedom position information for the LGMSS control system.

  8. High angle of attack position sensing for the Southampton University magnetic suspension and balance system

    NASA Technical Reports Server (NTRS)

    Parker, David H.

    1987-01-01

    An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.

  9. Electrolyte induced rheological modulation of graphene oxide suspensions and its applications in adsorption

    NASA Astrophysics Data System (ADS)

    Ojha, Abhijeet; Thareja, Prachi

    2018-03-01

    In this study, we report the microstructure, rheology and adsorption characteristics of aqueous suspensions of Graphene Oxide (GO) at a volume fraction (ϕGO) = 0.018, which can be transformed into gels by cation induced charge shielding and cross-linking between GO nanosheets. GO nanosheets of average thickness ∼1.5 nm and a lateral dimension of ∼750 nm are synthesized by Hummer's process. At ϕGO= 0.018, cations of varying size and valence are systematically introduced with electrolytes NH4Cl, LiCl, NaCl, KCl, MgCl2 and FeCl3 at concentrations ranging from 10-5-10-1 M to investigate their effect on the rheology of GO suspensions. Our results suggest that depending on the electrolyte concentration, size and the valence of the cation: low viscosity suspensions, fragile gels and solid-like GO-electrolyte gels are formed. The storage modulus (G') of all GO-electrolyte gels increases with the increase in electrolyte concentration and G' follows the order GO-FeCl3 > GO-MgCl2> GO-KCl > GO-NaCl > GO-LiCl > GO-NH4Cl. FESEM analysis shows that lyophilized GO-electrolyte gels with 10-1 M electrolytes have a porous morphology resulting from the aggregation of GO nanosheets. The GO-electrolyte gels are shown to adsorb high quantities of oils, with GO-FeCl3 gels showing a higher adsorption capacity. The GO-NaCl and GO-FeCl3 lyophilized gels are also shown to adsorb methylene blue dye and follow the pseudo-second-order kinetics of adsorption. Along with higher oil and dye adsorption efficiency, GO-electrolyte gels are easy to recollect after the adsorption, thus avoiding the potential toxicity for bio-organisms in water caused by GO nanosheets.

  10. MISSION LentiPlex pooled shRNA library screening in mammalian cells.

    PubMed

    Coussens, Matthew J; Corman, Courtney; Fischer, Ashley L; Sago, Jack; Swarthout, John

    2011-12-21

    RNA interference (RNAi) is an intrinsic cellular mechanism for the regulation of gene expression. Harnessing the innate power of this system enables us to knockdown gene expression levels in loss of gene function studies. There are two main methods for performing RNAi. The first is the use of small interfering RNAs (siRNAs) that are chemically synthesized, and the second utilizes short-hairpin RNAs (shRNAs) encoded within plasmids. The latter can be transfected into cells directly or packaged into replication incompetent lentiviral particles. The main advantages of using lentiviral shRNAs is the ease of introduction into a wide variety of cell types, their ability to stably integrate into the genome for long term gene knockdown and selection, and their efficacy in conducting high-throughput loss of function screens. To facilitate this we have created the LentiPlex pooled shRNA library. The MISSION LentiPlex Human shRNA Pooled Library is a genome-wide lentiviral pool produced using a proprietary process. The library consists of over 75,000 shRNA constructs from the TRC collection targeting 15,000+ human genes. Each library is tested for shRNA representation before product release to ensure robust library coverage. The library is provided in a ready-to-use lentiviral format at titers of at least 5 x 10(8) TU/ml via p24 assay and is pre-divided into ten subpools of approximately 8,000 shRNA constructs each. Amplification and sequencing primers are also provided for downstream target identification. Previous studies established a synergistic antitumor activity of TRAIL when combined with Paclitaxel in A549 cells, a human lung carcinoma cell line. In this study we demonstrate the application of a pooled LentiPlex shRNA library to rapidly conduct a positive selection screen for genes involved in the cytotoxicity of A549 cells when exposed to TRAIL and Paclitaxel. One barrier often encountered with high-throughput screens is the cost and difficulty in deconvolution; we also detail a cost-effective polyclonal approach utilizing traditional sequencing.

  11. Non-metal doped TiO2 nanotube arrays for high efficiency photocatalytic decomposition of organic species in water

    NASA Astrophysics Data System (ADS)

    Szkoda, Mariusz; Siuzdak, Katarzyna; Lisowska-Oleksiak, Anna

    2016-10-01

    Titanium dioxide is a well-known photoactive semiconductor with a variety of possible applications. The procedure of pollutant degradation is mainly performed using TiO2 powder suspension. It can also be exploited an immobilized catalyst on a solid support. Morphology and chemical doping have a great influence on TiO2 activity under illumination. Here we compare photoactivity of titania nanotube arrays doped with non-metal atoms: nitrogen, iodine and boron applied for photodegradation of organic dye - methylene blue and terephtalic acid. The doped samples act as a much better photocatalyst in the degradation process of methylene blue and lead to the formation of much higher amount of hydroxyl radicals (•OH) than undoped TiO2 nanotube arrays. The use of a catalyst active under solar light illumination in the form of thin films on a stable substrate can be scaled up for an industrial application.

  12. ArrayWiki: an enabling technology for sharing public microarray data repositories and meta-analyses

    PubMed Central

    Stokes, Todd H; Torrance, JT; Li, Henry; Wang, May D

    2008-01-01

    Background A survey of microarray databases reveals that most of the repository contents and data models are heterogeneous (i.e., data obtained from different chip manufacturers), and that the repositories provide only basic biological keywords linking to PubMed. As a result, it is difficult to find datasets using research context or analysis parameters information beyond a few keywords. For example, to reduce the "curse-of-dimension" problem in microarray analysis, the number of samples is often increased by merging array data from different datasets. Knowing chip data parameters such as pre-processing steps (e.g., normalization, artefact removal, etc), and knowing any previous biological validation of the dataset is essential due to the heterogeneity of the data. However, most of the microarray repositories do not have meta-data information in the first place, and do not have a a mechanism to add or insert this information. Thus, there is a critical need to create "intelligent" microarray repositories that (1) enable update of meta-data with the raw array data, and (2) provide standardized archiving protocols to minimize bias from the raw data sources. Results To address the problems discussed, we have developed a community maintained system called ArrayWiki that unites disparate meta-data of microarray meta-experiments from multiple primary sources with four key features. First, ArrayWiki provides a user-friendly knowledge management interface in addition to a programmable interface using standards developed by Wikipedia. Second, ArrayWiki includes automated quality control processes (caCORRECT) and novel visualization methods (BioPNG, Gel Plots), which provide extra information about data quality unavailable in other microarray repositories. Third, it provides a user-curation capability through the familiar Wiki interface. Fourth, ArrayWiki provides users with simple text-based searches across all experiment meta-data, and exposes data to search engine crawlers (Semantic Agents) such as Google to further enhance data discovery. Conclusions Microarray data and meta information in ArrayWiki are distributed and visualized using a novel and compact data storage format, BioPNG. Also, they are open to the research community for curation, modification, and contribution. By making a small investment of time to learn the syntax and structure common to all sites running MediaWiki software, domain scientists and practioners can all contribute to make better use of microarray technologies in research and medical practices. ArrayWiki is available at . PMID:18541053

  13. Nanoscale patterning controls inorganic-membrane interface structure

    NASA Astrophysics Data System (ADS)

    Almquist, Benjamin D.; Verma, Piyush; Cai, Wei; Melosh, Nicholas A.

    2011-02-01

    The ability to non-destructively integrate inorganic structures into or through biological membranes is essential to realizing full bio-inorganic integration, including arrayed on-chip patch-clamps, drug delivery, and biosensors. Here we explore the role of nanoscale patterning on the strength of biomembrane-inorganic interfaces. AFM measurements show that inorganic probes functionalized with hydrophobic bands with thicknesses complimentary to the hydrophobic lipid bilayer core exhibit strong attachment in the bilayer. As hydrophobic band thickness increases to 2-3 times the bilayer core the interfacial strength decreases, comparable to homogeneously hydrophobic probes. Analytical calculations and molecular dynamics simulations predict a transition between a `fused' interface and a `T-junction' that matches the experimental results, showing lipid disorder and defect formation for thicker bands. These results show that matching biological length scales leads to more intimate bio-inorganic junctions, enabling rational design of non-destructive membrane interfaces.The ability to non-destructively integrate inorganic structures into or through biological membranes is essential to realizing full bio-inorganic integration, including arrayed on-chip patch-clamps, drug delivery, and biosensors. Here we explore the role of nanoscale patterning on the strength of biomembrane-inorganic interfaces. AFM measurements show that inorganic probes functionalized with hydrophobic bands with thicknesses complimentary to the hydrophobic lipid bilayer core exhibit strong attachment in the bilayer. As hydrophobic band thickness increases to 2-3 times the bilayer core the interfacial strength decreases, comparable to homogeneously hydrophobic probes. Analytical calculations and molecular dynamics simulations predict a transition between a `fused' interface and a `T-junction' that matches the experimental results, showing lipid disorder and defect formation for thicker bands. These results show that matching biological length scales leads to more intimate bio-inorganic junctions, enabling rational design of non-destructive membrane interfaces. Electronic supplementary information (ESI) available: Breakthrough rate as a function of force plots for 5 nm, 10 nm and ∞-probes.. See DOI: 10.1039/c0nr00486c

  14. Nanoplasmonic Biosensor Using Localized Surface Plasmon Resonance Spectroscopy for Biochemical Detection.

    PubMed

    Zhang, Diming; Zhang, Qian; Lu, Yanli; Yao, Yao; Li, Shuang; Liu, Qingjun

    2017-01-01

    Localized surface plasmon resonance (LSPR) associated with metal nanostructures has developed into a highly useful sensor technique. Optical LSPR spectroscopy of nanostructures often shows sharp absorption and scattering peaks, which can be used to probe several bio-molecular interactions. Here, we report nanoplasmonic biosensors using LSPR on nanocup arrays (nanoCA) to recognize bio-molecular binding for biochemical detection. These sensors can be modified to quantify binding of small molecules to proteins for odorant and explosive detections. Electrochemical LSPR biosensors can also be designed by coupling electrochemistry and LSPR spectroscopy measurements. Multiple sensing information can be obtained and electrochemical LSPR property can be investigated for biosensors. In some applications, the electrochemical LSPR biosensor can be used to quantify immunoreactions and enzymatic activity. The biosensors exhibit better performance than those of conventional optical LSPR measurements. With multi-transducers, the nanoplasmonic biosensor can provide a promising approach for bio-detection in environmental monitoring, healthcare diagnostics, and food quality control.

  15. Dissolved oxygen sensing using organometallic dyes deposited within a microfluidic environment

    NASA Astrophysics Data System (ADS)

    Chen, Q. L.; Ho, H. P.; Jin, L.; Chu, B. W.-K.; Li, M. J.; Yam, V. W.-W.

    2008-02-01

    This work primarily aims to integrate dissolved oxygen sensing capability with a microfluidic platform containing arrays of micro bio-reactors or bio-activity indicators. The measurement of oxygen concentration is of significance for a variety of bio-related applications such as cell culture and gene expression. Optical oxygen sensors based on luminescence quenching are gaining much interest in light of their low power consumption, quick response and high analyte sensitivity in comparison to similar oxygen sensing devices. In our microfluidic oxygen sensor device, a thin layer of oxygen-sensitive luminescent organometallic dye is covalently bonded to a glass slide. Micro flow channels are formed on the glass slide using patterned PDMS (Polydimethylsiloxane). Dissolved oxygen sensing is then performed by directing an optical excitation probe beam to the area of interest within the microfluidic channel. The covalent bonding approach for sensor layer formation offers many distinct advantages over the physical entrapment method including minimizing dye leaching, ensuring good stability and fabrication simplicity. Experimental results confirm the feasibility of the device.

  16. Bio-inspired sensing and control for disturbance rejection and stabilization

    NASA Astrophysics Data System (ADS)

    Gremillion, Gregory; Humbert, James S.

    2015-05-01

    The successful operation of small unmanned aircraft systems (sUAS) in dynamic environments demands robust stability in the presence of exogenous disturbances. Flying insects are sensor-rich platforms, with highly redundant arrays of sensors distributed across the insect body that are integrated to extract rich information with diminished noise. This work presents a novel sensing framework in which measurements from an array of accelerometers distributed across a simulated flight vehicle are linearly combined to directly estimate the applied forces and torques with improvements in SNR. In simulation, the estimation performance is quantified as a function of sensor noise level, position estimate error, and sensor quantity.

  17. Nonlinear Optical Fiber Arrays for Limiting Application

    DTIC Science & Technology

    2006-09-05

    Absorption [ RSA ], Two-Photon Absorption [TPA] and Excited State Absorption [ESA] or Nonlinear Scattering properties [NS] (e.g. carbon black suspension...practical implementation: I. "Saturation Effect and Dynamic Range" - In general, RSA materials have low switching threshold (<<pJ), but are (linearly...transition between the molecular levels involved, RSA materials can be easily ’bleached’, i.e. the absorption electronic state is depopulated by the laser. TPA

  18. Naturally occurring anti-glycan antibodies binding to Globo H-expressing cells identify ovarian cancer patients.

    PubMed

    Pochechueva, Tatiana; Alam, Shahidul; Schötzau, Andreas; Chinarev, Alexander; Bovin, Nicolai V; Hacker, Neville F; Jacob, Francis; Heinzelmann-Schwarz, Viola

    2017-02-10

    Glycosphingolipids are important compounds of the plasma membrane of mammalian cells and a number of them have been associated with malignant transformation and progression, reinforcing tumour aggressiveness and metastasis. Here we investigated the levels of naturally occurring anti-glycan antibodies to Globo H in blood plasma obtained from high-grade serous ovarian cancer patients (SOC) and women without gynaecological malignancies (control) using suspension glycan array technology employing chemically synthesized glycans as antibody targets. We found that anti-human Globo H IgG antibodies were able to significantly discriminate SOC from controls (P < 0.05). A combination with the clinically used tumour marker CA125 increased the diagnostic performance (AUC 0.8711). We next compared suspension array with standard flow cytometry in plasma samples and found that the level of anti-Globo H antibodies highly correlated (r = 0.992). The incubation of plasma-derived anti-glycan antibodies with chemically synthesized (presented on fluorescence microspheres) and native Globo H (expressed on Globo H-positive cell lines) revealed strong reactivity of naturally occurring human anti-Globo H antibodies towards its antigen expressed on ovarian cancer cells. Our data demonstrate that human plasma-derived antibodies to Globo H as well as the presence of the antigen might be considered as therapeutic option in ovarian cancer.

  19. Development of conductometric biosensor array for simultaneous determination of maltose, lactose, sucrose and glucose.

    PubMed

    Soldatkin, O O; Peshkova, V M; Saiapina, O Y; Kucherenko, I S; Dudchenko, O Y; Melnyk, V G; Vasylenko, O D; Semenycheva, L M; Soldatkin, A P; Dzyadevych, S V

    2013-10-15

    The aim of this work was to develop an array of biosensors for simultaneous determination of four carbohydrates in solution. Several enzyme systems selective to lactose, maltose, sucrose and glucose were immobilised on the surface of four conductometric transducers and served as bio-recognition elements of the biosensor array. Direct enzyme analysis carried out by the developed biosensors was highly sensitive to the corresponding substrates. The analysis lasted 2 min. The dynamic range of substrate determination extended from 0.001 mM to 1.0-3.0mM, and strongly depended on the enzyme system used. An effect of the solution pH, ionic strength and buffer capacity on the biosensors responses was investigated; the conditions of simultaneous operation of all biosensors were optimised. The data on cross-impact of the substrates of all biosensors were obtained; the biosensor selectivity towards possible interfering carbohydrates was tested. The developed biosensor array showed good signal reproducibility and storage stability. The biosensor array is suited for simultaneous, quick, simple, and selective determination of maltose, lactose, sucrose and glucose. © 2013 Elsevier B.V. All rights reserved.

  20. Development of a Bio-inspired Microflap Array for Passive Control of Flow Separation

    NASA Astrophysics Data System (ADS)

    Devey, Sean; Morris, Jackson; Hubner, Paul; Lang, Amy

    2017-11-01

    The shortfin mako shark benefits from its flexible microscopic scales, or denticles; which can passively limit flow separation in water. These denticles can be passively actuated by incipient reversing flow in the lower 5% of the boundary layer, thereby impeding further flow reversal and promoting increased momentum exchange. In air, an array of flow actuated microflaps has the potential to provide similar benefits to man-made systems. Multiple iterations of microflap arrays have been developed and tested in the University of Alabama's Boundary Layer Tunnel. A variety of 3D-printed flaps derived from mako denticle geometries were arranged in rows with freedom to rotate, like mako denticles, to angles up to 50 degrees. Placing the microflap array in separated flow regions allowed for direct observation of the microflap response. Like mako denticles, microflaps with lengths of about 4 mm have been shown to actuate in response to reversing surface flows. This presentation will focus on the development and implementation of passive microflap arrays. This research was supported by Boeing, the US Army, and the National Science Foundation REU program.

  1. Supercolor coding methods for large-scale multiplexing of biochemical assays.

    PubMed

    Rajagopal, Aditya; Scherer, Axel; Homyk, Andrew; Kartalov, Emil

    2013-08-20

    We present a novel method for the encoding and decoding of multiplexed biochemical assays. The method enables a theoretically unlimited number of independent targets to be detected and uniquely identified in any combination in the same sample. For example, the method offers easy access to 12-plex and larger PCR assays, as contrasted to the current 4-plex assays. This advancement would allow for large panels of tests to be run simultaneously in the same sample, saving reagents, time, consumables, and manual labor, while also avoiding the traditional loss of sensitivity due to sample aliquoting. Thus, the presented method is a major technological breakthrough with far-reaching impact on biotechnology, biomedical science, and clinical diagnostics. Herein, we present the mathematical theory behind the method as well as its experimental proof of principle using Taqman PCR on sequences specific to infectious diseases.

  2. Partition resampling and extrapolation averaging: approximation methods for quantifying gene expression in large numbers of short oligonucleotide arrays.

    PubMed

    Goldstein, Darlene R

    2006-10-01

    Studies of gene expression using high-density short oligonucleotide arrays have become a standard in a variety of biological contexts. Of the expression measures that have been proposed to quantify expression in these arrays, multi-chip-based measures have been shown to perform well. As gene expression studies increase in size, however, utilizing multi-chip expression measures is more challenging in terms of computing memory requirements and time. A strategic alternative to exact multi-chip quantification on a full large chip set is to approximate expression values based on subsets of chips. This paper introduces an extrapolation method, Extrapolation Averaging (EA), and a resampling method, Partition Resampling (PR), to approximate expression in large studies. An examination of properties indicates that subset-based methods can perform well compared with exact expression quantification. The focus is on short oligonucleotide chips, but the same ideas apply equally well to any array type for which expression is quantified using an entire set of arrays, rather than for only a single array at a time. Software implementing Partition Resampling and Extrapolation Averaging is under development as an R package for the BioConductor project.

  3. A quartz nanopillar hemocytometer for high-yield separation and counting of CD4+ T lymphocytes

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Joo; Seol, Jin-Kyeong; Wu, Yu; Ji, Seungmuk; Kim, Gil-Sung; Hyung, Jung-Hwan; Lee, Seung-Yong; Lim, Hyuneui; Fan, Rong; Lee, Sang-Kwon

    2012-03-01

    We report the development of a novel quartz nanopillar (QNP) array cell separation system capable of selectively capturing and isolating a single cell population including primary CD4+ T lymphocytes from the whole pool of splenocytes. Integrated with a photolithographically patterned hemocytometer structure, the streptavidin (STR)-functionalized-QNP (STR-QNP) arrays allow for direct quantitation of captured cells using high content imaging. This technology exhibits an excellent separation yield (efficiency) of ~95.3 +/- 1.1% for the CD4+ T lymphocytes from the mouse splenocyte suspensions and good linear response for quantitating captured CD4+ T-lymphoblasts, which is comparable to flow cytometry and outperforms any non-nanostructured surface capture techniques, i.e. cell panning. This nanopillar hemocytometer represents a simple, yet efficient cell capture and counting technology and may find immediate applications for diagnosis and immune monitoring in the point-of-care setting.We report the development of a novel quartz nanopillar (QNP) array cell separation system capable of selectively capturing and isolating a single cell population including primary CD4+ T lymphocytes from the whole pool of splenocytes. Integrated with a photolithographically patterned hemocytometer structure, the streptavidin (STR)-functionalized-QNP (STR-QNP) arrays allow for direct quantitation of captured cells using high content imaging. This technology exhibits an excellent separation yield (efficiency) of ~95.3 +/- 1.1% for the CD4+ T lymphocytes from the mouse splenocyte suspensions and good linear response for quantitating captured CD4+ T-lymphoblasts, which is comparable to flow cytometry and outperforms any non-nanostructured surface capture techniques, i.e. cell panning. This nanopillar hemocytometer represents a simple, yet efficient cell capture and counting technology and may find immediate applications for diagnosis and immune monitoring in the point-of-care setting. Electronic supplementary information (ESI) available. See DOI: 10.1039/c2nr11338d

  4. [Detection of transgenic crop with gene chip].

    PubMed

    Huang, Ying-Chun; Sun, Chun-Yun; Feng, Hong; Hu, Xiao-Dong; Yin, Hai-Bin

    2003-05-01

    Some selected available sequences of reporter genes,resistant genes, promoters and terminators are amplified by PCR for the probes of transgenic crop detection gene chip. These probes are arrayed at definite density and printed on the surface of amino-slides by bioRobot MicroGrid II. Results showed that gene chip worked quickly and correctly, when transgenic rice, pawpaw,maize and soybean were applied.

  5. Experimental demonstration of a novel bio-sensing platform via plasmonic band gap formation in gold nano-patch arrays.

    PubMed

    Grande, Marco; Vincenti, Maria Antonietta; Stomeo, Tiziana; Morea, Giuseppe; Marani, Roberto; Marrocco, Valeria; Petruzzelli, Vincenzo; D'Orazio, Antonella; Cingolani, Roberto; De Vittorio, Massimo; de Ceglia, Domenico; Scalora, Michael

    2011-10-24

    In this paper we discuss the possibility of implementing a novel bio-sensing platform based on the observation of the shift of the leaky surface plasmon mode that occurs at the edge of the plasmonic band gap of metal gratings, when an analyte is deposited on top of the metallic structure. We report numerical calculations, fabrication and experimental measurements to prove the sensing capability of a two-dimensional array of gold nano-patches in the detection of a small quantity of Isopropyl Alcohol (IPA) deposited on top of sensor surface. The calculated sensitivity of our device approaches a value of 1000 nm/RIU with a corresponding Figure of Merit (FOM) of 222 RIU(-1). The presence of IPA can also be visually estimated by observing a color variation in the diffracted field. We show that color brightness and intensity variations can be ascribed to a change in the aperture size, keeping the periodicity constant, and to different types of analyte deposited on the sample, respectively. Moreover, we demonstrate that unavoidable fabrication imperfections revealed by the presence of rounded corners and surface roughness do not significantly affect device performance. © 2011 Optical Society of America

  6. FIB-tomographic studies on chemical vapor deposition grown SnO2 nanowire arrays on TiO2 (001)

    NASA Astrophysics Data System (ADS)

    Chen, Haoyun; Liu, Yi; Wu, Hong; Xiong, Xiang; Pan, Jun

    2016-12-01

    Tin oxide nanowire arrays on titania (001) have been successfully fabricated by chemical vapor deposition of Sn(O t Bu)4 precursor. The morphologies and structures of ordered SnO2 nanowires (NWs) were analyzed by cross-sectional SEM, HR-TEM and AFM. An FIB-tomography technique was applied in order to reconstruct a 3D presentation of ordered SnO2 nanowires. The achieved 3D analysis showed the spatial orientation and angles of ordered SnO2 NWs can be obtained in a one-shot experiment, and the distribution of Au catalysts showed the competition between 1D and 2D growth. The SnO2 nanowire arrays can be potentially used as a diameter- and surface-dependent sensing unit for the detection of gas- and bio-molecules.

  7. NASA Tech Briefs, May 2003

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Topics covered include: Using Diffusion Bonding in Making Piezoelectric Actuators; Wireless Temperature-Monitoring System; Analog Binaural Circuits for Detecting and Locating Leaks; Mirrors Containing Biomimetic Shape-Control Actuators; Surface-Micromachined Planar Arrays of Thermopiles; Cascade Back-Propagation Learning in Neural Networks; Perovskite Superlattices as Tunable Microwave Devices; Rollable Thin-Shell Nanolaminate Mirrors; Flight Tests of a Ministick Controller in an F/A-18 Airplane; Piezoelectrically Actuated Shutter for High Vacuum; Bio-Inspired Engineering of Exploration Systems; Microscope Cells Containing Multiple Micromachined Wells; Electrophoretic Deposition for Fabricating Microbatteries; Integrated Arrays of Ion-Sensitive Electrodes; Model of Fluidized Bed Containing Reacting Solids and Gases; Membrane Mirrors With Bimorph Shape Actuators; Using Fractional Clock-Period Delays in Telemetry Arraying; Developing Generic Software for Spacecraft Avionics; Numerical Study of Pyrolysis of Biomass in Fluidized Beds; and Assessment of Models of Chemically Reacting Granular Flows.

  8. SERS detection of R6G based on a novel graphene oxide/silver nanoparticles/silicon pyramid arrays structure.

    PubMed

    Zhang, C; Jiang, S Z; Huo, Y Y; Liu, A H; Xu, S C; Liu, X Y; Sun, Z C; Xu, Y Y; Li, Z; Man, B Y

    2015-09-21

    We present a novel surface-enhanced Raman scattering (SERS) substrate based on graphene oxide/silver nanoparticles/silicon pyramid arrays structure (GO/Ag/PSi). The SERS behaviors are discussed and compared by the detection of R6G. Based on the contrast experiments with PSi, GO/PSi, Ag/PSi and GO/AgA/PSi as SERS substrate, the perfect bio-compatibility, good homogeneity and chemical stability were confirmed. We also calculated the electric field distributions using Finite-difference time-domain (FDTD) analysis to further understand the GO/Ag/PSi structure as a perfect SERS platform. These experimental and theoretical results imply that the GO/Ag/PSi with regular pyramids array is expected to be an effective substrate for label-free sensitive SERS detections in areas of medicine, food safety and biotechnology.

  9. Human Centered Autonomous and Assistant Systems Testbed for Exploration Operations

    NASA Technical Reports Server (NTRS)

    Malin, Jane T.; Mount, Frances; Carreon, Patricia; Torney, Susan E.

    2001-01-01

    The Engineering and Mission Operations Directorates at NASA Johnson Space Center are combining laboratories and expertise to establish the Human Centered Autonomous and Assistant Systems Testbed for Exploration Operations. This is a testbed for human centered design, development and evaluation of intelligent autonomous and assistant systems that will be needed for human exploration and development of space. This project will improve human-centered analysis, design and evaluation methods for developing intelligent software. This software will support human-machine cognitive and collaborative activities in future interplanetary work environments where distributed computer and human agents cooperate. We are developing and evaluating prototype intelligent systems for distributed multi-agent mixed-initiative operations. The primary target domain is control of life support systems in a planetary base. Technical approaches will be evaluated for use during extended manned tests in the target domain, the Bioregenerative Advanced Life Support Systems Test Complex (BIO-Plex). A spinoff target domain is the International Space Station (ISS) Mission Control Center (MCC). Prodl}cts of this project include human-centered intelligent software technology, innovative human interface designs, and human-centered software development processes, methods and products. The testbed uses adjustable autonomy software and life support systems simulation models from the Adjustable Autonomy Testbed, to represent operations on the remote planet. Ground operations prototypes and concepts will be evaluated in the Exploration Planning and Operations Center (ExPOC) and Jupiter Facility.

  10. Induction by TNF-α of IL-6 and IL-8 in cystic fibrosis bronchial IB3-1 epithelial cells encapsulated in alginate microbeads.

    PubMed

    Borgatti, Monica; Mazzitelli, Stefania; Breveglieri, Giulia; Gambari, Roberto; Nastruzzi, Claudio

    2010-01-01

    We have developed a microencapsulation procedure for the entrapment and manipulation of IB3-1 cystic fibrosis cells. The applied method is based on generation of monodisperse droplets by a vibrational nozzle. Different experimental parameters were analyzed, including frequency and amplitude of vibration, polymer pumping rate and distance between the nozzle and the gelling bath. We have found that the microencapsulation procedure does not alter the viability of the encapsulated IB3-1 cells. The encapsulated IB3-1 cells were characterized in term of secretomic profile, analyzing the culture medium by Bio-Plex strategy. The experiments demonstrated that most of the analyzed proteins, were secreted both by the free and encapsulated cells, even if in a different extent. In order to determine the biotechnological applications of this procedure, we determined whether encapsulated IB3-1 cells could be induced to pro-inflammatory responses, after treatment with TNF-α. In this experimental set-up, encapsulated and free IB3-1 cells were treated with TNF-α, thereafter the culture media from both cell populations were collected. As expected, TNF-α induced a sharp increase in the secretion of interleukins, chemokines and growth factors. Of great interest was the evidence that induction of interleukin-6 and interleukin-8 occurs also by encapsulated IB3-1 cells.

  11. Bio-inspired direct patterning functional nanothin microlines: controllable liquid transfer.

    PubMed

    Wang, Qianbin; Meng, Qingan; Wang, Pengwei; Liu, Huan; Jiang, Lei

    2015-04-28

    Developing a general and low-cost strategy that enables direct patterning of microlines with nanometer thickness from versatile liquid-phase functional materials and precise positioning of them on various substrates remains a challenge. Herein, with inspiration from the oriental wisdom to control ink transfer by Chinese brushes, we developed a facile and general writing strategy to directly pattern various functional microlines with homogeneous distribution and nanometer-scale thickness. It is demonstrated that the width and thickness of the microlines could be well-controlled by tuning the writing method, providing guidance for the adaptation of this technique to various systems. It is also shown that various functional liquid-phase materials, such as quantum dots, small molecules, polymers, and suspensions of nanoparticles, could directly write on the substrates with intrinsic physicochemical properties well-preserved. Moreover, this technique enabled direct patterning of liquid-phase materials on certain microdomains, even in multiple layered style, thus a microdomain localized chemical reaction and the patterned surface chemical modification were enabled. This bio-inspired direct writing device will shed light on the template-free printing of various functional micropatterns, as well as the integrated functional microdevices.

  12. Photosystem I assembly on chemically tailored SAM/ Au substrates for bio-hybrid device fabrication

    NASA Astrophysics Data System (ADS)

    Mukherjee, Dibyendu; Khomami, Bamin

    2011-03-01

    Photosystem I (PS I), a supra-molecular protein complex and a biological photodiode responsible for driving natural photosynthesis mechanism, charge separates upon exposure to light. Effective use of the photo-electrochemical activities of PS I for future bio-hybrid electronic devices requires controlled attachment of these proteins onto organic/ inorganic substrates. Our results indicate that various experimental parameters alter the surface topography of PS I deposited from colloidal aqueous buffer suspensions onto OH-terminated alkanethiolate SAM /Au substrates, thereby resulting in complex columnar structures that affect the electron capture pathway of PS I. Specifically, solution phase characterizations indicate that specific detergents used for PS I stabilization in buffer solutions drive the unique colloidal chemistry to tune protein-protein interactions and prevent aggregation, thereby allowing us to tailor the morphology of surface immobilized PS I. We present surface topographical, adsorption, and electrochemical characterizations of PSI /SAM/Au substrates to elucidate protein-surface attachment dynamics and its effect on the photo-activated electronic activities of surface immobilized PS I. Sustainable Energy Education and Research Center (SEERC).

  13. A tracked robot with novel bio-inspired passive "legs".

    PubMed

    Sun, Bo; Jing, Xingjian

    2017-01-01

    For track-based robots, an important aspect is the suppression design, which determines the trafficability and comfort of the whole system. The trafficability limits the robot's working capability, and the riding comfort limits the robot's working effectiveness, especially with some sensitive instruments mounted on or operated. To these aims, a track-based robot equipped with a novel passive bio-inspired suspension is designed and studied systematically in this paper. Animal or insects have very special leg or limb structures which are good for motion control and adaptable to different environments. Inspired by this, a new track-based robot is designed with novel "legs" for connecting the loading wheels to the robot body. Each leg is designed with passive structures and can achieve very high loading capacity but low dynamic stiffness such that the robot can move on rough ground similar to a multi-leg animal or insect. Therefore, the trafficability and riding comfort can be significantly improved without losing loading capacity. The new track-based robot can be well applied to various engineering tasks for providing a stable moving platform of high mobility, better trafficability and excellent loading capacity.

  14. Standoff detection and classification of bacteria by multispectral laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    Duschek, Frank; Fellner, Lea; Gebert, Florian; Grünewald, Karin; Köhntopp, Anja; Kraus, Marian; Mahnke, Peter; Pargmann, Carsten; Tomaso, Herbert; Walter, Arne

    2017-04-01

    Biological hazardous substances such as certain fungi and bacteria represent a high risk for the broad public if fallen into wrong hands. Incidents based on bio-agents are commonly considered to have unpredictable and complex consequences for first responders and people. The impact of such an event can be minimized by an early and fast detection of hazards. The presented approach is based on optical standoff detection applying laser-induced fluorescence (LIF) on bacteria. The LIF bio-detector has been designed for outdoor operation at standoff distances from 20 m up to more than 100 m. The detector acquires LIF spectral data for two different excitation wavelengths (280 and 355 nm) which can be used to classify suspicious samples. A correlation analysis and spectral classification by a decision tree is used to discriminate between the measured samples. In order to demonstrate the capabilities of the system, suspensions of the low-risk and non-pathogenic bacteria Bacillus thuringiensis, Bacillus atrophaeus, Bacillus subtilis, Brevibacillus brevis, Micrococcus luteus, Oligella urethralis, Paenibacillus polymyxa and Escherichia coli (K12) have been investigated with the system, resulting in a discrimination accuracy of about 90%.

  15. MMP9 polymorphisms and breast cancer risk: a report from the Shanghai Breast Cancer Genetics Study.

    PubMed

    Beeghly-Fadiel, Alicia; Lu, Wei; Shu, Xiao-Ou; Long, Jirong; Cai, Qiuyin; Xiang, Yongbin; Gao, Yu-Tang; Zheng, Wei

    2011-04-01

    In addition to tumor invasion and angiogenesis, matrix metalloproteinase (MMP)9 also contributes to carcinogenesis and tumor growth. Genetic variation that may influence MMP9 expression was evaluated among participants of the Shanghai Breast Cancer Genetics Study (SBCGS) for associations with breast cancer susceptibility. In stage 1, 11 MMP9 single nucleotide polymorphisms (SNPs) were genotyped by the Affymetrix Targeted Genotyping System and/or the Affymetrix Genome-Wide Human SNP Array 6.0 among 4,227 SBCGS participants. One SNP was further genotyped using the Sequenom iPLEX MassARRAY platform among an additional 6,270 SBCGS participants. Associations with breast cancer risk were evaluated by odds ratios (OR) and 95% confidence intervals (CI) from logistic regression models that included adjustment for age, education, and genotyping stage when appropriate. In Stage 1, rare allele homozygotes for a promoter SNP (rs3918241) or a non-synonymous SNP (rs2274756, R668Q) tended to occur more frequently among breast cancer cases (P value = 0.116 and 0.056, respectively). Given their high linkage disequilibrium (D' = 1.0, r (2) = 0.97), one (rs3918241) was selected for additional analysis. An association with breast cancer risk was not supported by additional Stage 2 genotyping. In combined analysis, no elevated risk of breast cancer among homozygotes was found (OR: 1.2, 95% CI: 0.8-1.8). Common genetic variation in MMP9 was not found to be significantly associated with breast cancer susceptibility among participants of the Shanghai Breast Cancer Genetics Study.

  16. A superconducting large-angle magnetic suspension

    NASA Technical Reports Server (NTRS)

    Downer, James R.; Anastas, George V., Jr.; Bushko, Dariusz A.; Flynn, Frederick J.; Goldie, James H.; Gondhalekar, Vijay; Hawkey, Timothy J.; Hockney, Richard L.; Torti, Richard P.

    1992-01-01

    SatCon Technology Corporation has completed a Small Business Innovation Research (SBIR) Phase 2 program to develop a Superconducting Large-Angle Magnetic Suspension (LAMS) for the NASA Langley Research Center. The Superconducting LAMS was a hardware demonstration of the control technology required to develop an advanced momentum exchange effector. The Phase 2 research was directed toward the demonstration for the key technology required for the advanced concept CMG, the controller. The Phase 2 hardware consists of a superconducting solenoid ('source coils') suspended within an array of nonsuperconducting coils ('control coils'), a five-degree-of-freedom positioning sensing system, switching power amplifiers, and a digital control system. The results demonstrated the feasibility of suspending the source coil. Gimballing (pointing the axis of the source coil) was demonstrated over a limited range. With further development of the rotation sensing system, enhanced angular freedom should be possible.

  17. A superconducting large-angle magnetic suspension

    NASA Astrophysics Data System (ADS)

    Downer, James R.; Anastas, George V., Jr.; Bushko, Dariusz A.; Flynn, Frederick J.; Goldie, James H.; Gondhalekar, Vijay; Hawkey, Timothy J.; Hockney, Richard L.; Torti, Richard P.

    1992-12-01

    SatCon Technology Corporation has completed a Small Business Innovation Research (SBIR) Phase 2 program to develop a Superconducting Large-Angle Magnetic Suspension (LAMS) for the NASA Langley Research Center. The Superconducting LAMS was a hardware demonstration of the control technology required to develop an advanced momentum exchange effector. The Phase 2 research was directed toward the demonstration for the key technology required for the advanced concept CMG, the controller. The Phase 2 hardware consists of a superconducting solenoid ('source coils') suspended within an array of nonsuperconducting coils ('control coils'), a five-degree-of-freedom positioning sensing system, switching power amplifiers, and a digital control system. The results demonstrated the feasibility of suspending the source coil. Gimballing (pointing the axis of the source coil) was demonstrated over a limited range. With further development of the rotation sensing system, enhanced angular freedom should be possible.

  18. Fixed site neutralization model programmer's manual. Volume II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engi, D.; Chapman, L.D.; Judnick, W.

    This report relates to protection of nuclear materials at nuclear facilities. This volume presents the source listings for the Fixed Site Neutralization Model and its supporting modules, the Plex Preprocessor and the Data Preprocessor. (DLC)

  19. Toxicity of monazite particulates and its attenuation with a complex of bio-protectors.

    PubMed

    Katsnelson, B A; Yeremenko, Olga S; Privalova, Larissa I; Makeyev, O H; Degtyareva, Tamara D; Beresneva, Olga Yu; Valamina, Irene E; Minihaliyeva, Ilzira A; Sutunkova, Marina P; Kireyeva, Ekaterina P; Bukhantsev, V A; Dovzenko, E I; Minin, V V; Kulikov, E S; Kostykova, Svetlana V; Nazukin, A S

    2009-01-01

    Workers employed on mining, processing and storage of monazite are at risk of exposure to dust with expected adverse health effects. To study the adverse health effects of monazite particles in experiments on rats and to test the possibility of attenuating these effects. Outbred white rats were injected intratracheally with a suspension of ground monazite concentrate (MC) in order to investigate the cellular response of the lower airways 24 hours later and the organism's status 6 months after the injection. The bio-protective complex (BPC) tested in these experiments consisted of glutamate, an iodine preparation, methionine, a polyvitamin-polymineral composition, and/or "Eicosavitol" (fish oil preparation rich in PUFA, predominantly of the omega 3-group). Bio-protectors were administered together with the rat food and drink daily for one month before the MC injection in the short-term experiment, or over 6 months after such injection in the long-term experiment. MC induced manifestations of its cytotoxicity, fibrogenicity and systemic toxicity as well as genotoxicity. The tested BPC attenuated virtually all these effects. Although a similar protective potential of "Eicosavitol" against almost all of them was lower compared with that of BPC, combining BPC with "Eicosavitol" provided, as a rule, the greatest protective effect. It may be assumed that the many-sided adverse effects of MC on the organism is due, at least partially, to the presence in its composition of not only rare earth elements but also of natural radioisotopes of the thorium and uranium families. The combination of the bio-protectors tested was highly effective and may be recommended for administering in periodic preventive programmes to exposed workers.

  20. Analysis of the effects of essential oils on airborne bacteria in a customized bio-clean room.

    PubMed

    Yang, Hyun; Koo, Tae-Hyoung; Hong, Chang-Young; Choi, In-Gyu; Jeung, Eui-Bae

    2012-09-01

    Essential oils have a sedative effect on stress, and are also known to have antibiotic and anti-carcinogenic effects. These compounds have long been used as natural microbial agents, and have recently been added to a number of pharmaceutical, food and cosmetic products. Controlling the exposure to allergens and pathogens are important factors for the treatment of allergy, and potentially reducing the risk of sensitization and infection. Low humidity, at levels under 35%, may affect human comfort and health during the winter. Patients and other individuals require optimal humidification to maintain a moisturized respiratory tract necessary for protecting against bacterial infection. We designed an analytical system to examine the effects of aromatherapeutic essential oils on airborne bacteria. The antibacterial activities of essential oils were assayed using agar plate air-sampling methods. A bacterial suspension was sprayed into a bio-clean room through the upper holes using a spray gun. Free-floating airborne bacteria were collected from the bio-clean room (blank) in blood agar plates for 10 sec using an air sampler. Three different concentrations of essential oils (0.0005, 0.005 and 0.05 ppm) were then sprayed into the bio-clean room for 5 min. Free-floating airborne bacteria were collected every 10 min for 10 sec each. Treatment with 0.0005 ppm essential oils inhibited the growth of colonies; this effect appeared to persist after 60 min. Decreased bacterial colony growth was more apparent in the presence of 0.005 ppm and 0.05 ppm essential oils than 0.0005 ppm. These effects were observed after 60 min compared to the control (distilled water). These results indicate that essential oils are able to inhibit the growth of airborne bacteria.

  1. Standoff laser-induced fluorescence of suspensions from different bacterial strains

    NASA Astrophysics Data System (ADS)

    Duschek, Frank; Walter, Arne; Fellner, Lea; Grünewald, Karin; Pargmann, Carsten; Handke, Jürgen; Tomaso, Herbert

    2016-10-01

    Biological hazardous substances like certain fungi and bacteria represent a high risk for the broad public if fallen into wrong hands. Incidents based on bio agents are commonly considered to have incalculable and complex consequences for first responders and people. The impact of such an event can be minimized by a combination of different sensor technologies that have been developed to detect bio-threats and to gather information after an incident. Sensors for bio-agents can be grouped into two categories. Sampling devices collect material from locations supposed to be contaminated, and they are able to identify biological material with high sensitivity and selectivity. However, these point sensors need to be positioned correctly in advance of an attack, and moving sources of biological material cannot be tracked. A different approach is based on optical standoff detection. For biological samples laser induced florescence (LIF) has been proven to get real time data on location and type of hazards without being in contact with the suspicious substance. This work is based on a bio-detector developed at the DLR Lampoldshausen. The LIF detection has been designed for outdoor operation at standoff distances from 20 m up to more than 100 m. The detector acquires LIF spectral data for two different excitation wavelengths (280 and 355 nm) as well as time resolved information for the fluorescence decay which can be used to classify suspicious samples. While the classification device had been trained on uncritical samples (like amino acids, NADH, yeast, chemicals, oils), this work presents the progress to more relevant, living bacteria of different strains. The low risk and non-pathogenic bacteria Bacillus thuringensis, Bacillus atrophaeus, Bacillus subtilis, Brevibacillus brevis, Micrococcus luteus, Oligella urethralis, Paenibacillus polymyxa and Escherichia coli (K12) have been investigated with the above set-up at both excitation wavelengths

  2. Innovative Multiphase Nanoparticle Composites Developed Using Electrophoresis And Electromigration

    DTIC Science & Technology

    2008-12-01

    Fig. 2. Surface of enamel steel sheet showing the array of fine cracks in the enamel . Copper metal was deposited on the...suspensions of enameling frit are used, a layer of glass particles can be built up that can be fused into a tightly bonded vitreous coating. 1...Prescribed by ANSI Std Z39-18 Electrophoresis has been particularly important in enameling because it can deposit a glassy frit layer uniformly

  3. Does Uniformity of Topical Corticosteroid Ophthalmic Medications: Flourometholone Acetate 0.1 Suspension and Loteprednol Etabonate 0.5 gel

    DTIC Science & Technology

    2017-01-03

    chromatography ( HPLC ) with photodiode array detection at 240 nm. Results: Flarex® had a mean concentration of 93.7% of the declared concentration when shaken...59 60 Journal of Ocular Pharmacology and Therapeutics Charlton E Stevens Rockville, MD. Methanol, ( HPLC grade), was obtained from Sigma-Aldrich...ST. Louis, MO. HPLC analysis of fluorometholone acetate and loteprednol etabonate HPLC analysis of fluorometholone acetate and loteprednol

  4. Characterization of Contrast Agent Microbubbles for Ultrasound Imaging and Therapy Research.

    PubMed

    Mulvana, Helen; Browning, Richard J; Luan, Ying; de Jong, Nico; Tang, Meng-Xing; Eckersley, Robert J; Stride, Eleanor

    2017-01-01

    The high efficiency with which gas microbubbles can scatter ultrasound compared with the surrounding blood pool or tissues has led to their widespread employment as contrast agents in ultrasound imaging. In recent years, their applications have been extended to include super-resolution imaging and the stimulation of localized bio-effects for therapy. The growing exploitation of contrast agents in ultrasound and in particular these recent developments have amplified the need to characterize and fully understand microbubble behavior. The aim in doing so is to more fully exploit their utility for both diagnostic imaging and potential future therapeutic applications. This paper presents the key characteristics of microbubbles that determine their efficacy in diagnostic and therapeutic applications and the corresponding techniques for their measurement. In each case, we have presented information regarding the methods available and their respective strengths and limitations, with the aim of presenting information relevant to the selection of appropriate characterization methods. First, we examine methods for determining the physical properties of microbubble suspensions and then techniques for acoustic characterization of both suspensions and single microbubbles. The next section covers characterization of microbubbles as therapeutic agents, including as drug carriers for which detailed understanding of their surface characteristics and drug loading capacity is required. Finally, we discuss the attempts that have been made to allow comparison across the methods employed by various groups to characterize and describe their microbubble suspensions and promote wider discussion and comparison of microbubble behavior.

  5. Novel and simple route to fabricate fully biocompatible plasmonic mushroom arrays adhered on silk biopolymer.

    PubMed

    Park, Joonhan; Choi, Yunkyoung; Lee, Myungjae; Jeon, Heonsu; Kim, Sunghwan

    2015-01-14

    A fully biocompatible plasmonic quasi-3D nanostructure is demonstrated by a simple and reliable fabrication method using strong adhesion between gold and silk fibroin. The quasi-3D nature gives rise to complex photonic responses in reflectance that are prospectively useful in bio/chemical sensing applications. Laser interference lithography is utilized to fabricate large-area plasmonic nanostructures.

  6. Development of a novel hexa-plex PCR method for identification and serotyping of Salmonella species.

    PubMed

    Li, Ruichao; Wang, Yang; Shen, Jianzhong; Wu, Congming

    2014-01-01

    Salmonella is one of the most important foodborne pathogens, which causes a huge economic burden worldwide. To detect Salmonella rapidly is very meaningful in preventing salmonellosis and decreasing economic losses. Currently, isolation of Salmonella is confirmed by biochemical and serobased serotyping methods, which are time consuming, labor intensive, and complicated. To solve this problem, a hexa-plex polymerase chain reaction (PCR) method was developed using comparative genomics analysis and multiplex PCR technology to detect Salmonella and Salmonella Typhimurium, Salmonella Enteritidis, Salmonella Agona, Salmonella Choleraesuis, and Salmonella Pullorum simultaneously. The accuracy of this method was tested by a collection of 142 Salmonella. Furthermore, the strategy described in this article to mine serovar-specific fragments for Salmonella could be used to find specific fragments for other Salmonella serotypes and bacteria. The combination of this strategy and multiplex PCR is promising in the rapid identification of foodborne pathogens.

  7. A silent allele in the locus D5S818 contained within the PowerPlex®21 PCR Amplification Kit.

    PubMed

    Chen, Ling; Tai, Yunchun; Qiu, Pingming; Du, Weian; Liu, Chao

    2015-11-01

    Three paternity tests cases were found with a single locus mismatch at the locus D5S818 with PowerPlex®21 PCR Amplification Kit (Promega). Forward and reverse primers were redesigned to type the samples again and to evaluate if there were alleles dropped out. The results showed the existence of a silent allele 12 in all the three families, due to a point mutation that changed cytosine to adenine at 90 nucleotides upstream from the 5' end of the AGAT repeat sequences in all the six individuals. A single locus mismatch due to a silent allele may occur in any locus using any kit. Therefore, we recommend using multiple kits to confirm the results in paternity testing cases with mismatches, especially when there is a single locus mismatch with homozygote involved. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Population genetic data of the AmpFℓSTR® Identifiler® Plus and PowerPlex® 16 HS STR loci in four Canadian populations.

    PubMed

    Laurin, Nancy; Milot, Emmanuel

    2014-03-01

    Allele frequencies and forensically relevant population statistics were estimated for the short tandem repeat (STR) loci of the AmpFℓSTR® Identifiler® Plus and PowerPlex® 16 HS amplification kits, including D2S1338, D19S433, Penta D, and Penta E, for three First Nations Aboriginal populations and for Caucasians in Canada. The cumulative power of discrimination was ≥ 0.999999999999984 and the cumulative power of exclusion was ≥ 0.999929363 for both amplification systems in all populations. No significant departure from Hardy-Weinberg equilibrium was detected for D2S1338, D19S433, Penta D, and Penta E or the 13 Combined DNA Index System core STR loci after correction for multiple testing. Significant genetic diversity was observed between these four populations. Comparison with published frequency data for other populations is also presented.

  9. Schottky-contact plasmonic rectenna for biosensing

    NASA Astrophysics Data System (ADS)

    Alavirad, Mohammad; Siadat Mousavi, Saba; Roy, Langis; Berini, Pierre

    2013-10-01

    We propose a plasmonic gold nanodipole array on silicon, forming a Schottky contact thereon, and covered by water. The behavior of this array under normal excitation has been extensively investigated. Trends have been found and confirmed by identification of the mode propagating in nanodipoles and its properties. This device can be used to detect infrared radiation below the bandgap energy of the substrate via internal photoelectric effect (IPE). Also we estimate its responsivity and detection limit. Finally, we assess the potential of the structure for bulk and surface (bio) chemical sensing. Based on modal results an analytical model has been proposed to estimate the sensitivity of the device. Results show a good agreement between numerical and analytical interpretations.

  10. Development of an IrO x micro pH sensor array on flexible polymer substrate

    NASA Astrophysics Data System (ADS)

    Huang, Wen-Ding; Wang, Jianqun; Ativanichayaphong, Thermpon; Chiao, Mu; Chiao, J. C.

    2008-03-01

    pH sensor is an essential component used in many chemical, food, and bio-material industries. Conventional glass electrodes have been used to construct pH sensors, however, have some disadvantages in specific applications. It is difficult to use glass electrodes for in vivo biomedical or food monitoring applications due to size limitation and no deformability. In this paper, we present design and fabrication processes of a miniature iridium oxide thin film pH sensor array on flexible polymer substrates. The amorphous iridium oxide thin film was used as the sensing material. A sol-gel dip-coating process of iridium oxide film was demonstrated in this paper. A super-Nernstian response has been measured on individual sensors of the array with a slope of -71.6+/-3 mV/pH at 25°C within the pH range between 2.83 and 11.04.

  11. A Bidirectional Neural Interface IC with Chopper Stabilized BioADC Array and Charge Balanced Stimulator

    PubMed Central

    Greenwald, Elliot; So, Ernest; Wang, Qihong; Mollazadeh, Mohsen; Maier, Christoph; Etienne-Cummings, Ralph; Cauwenberghs, Gert; Thakor, Nitish

    2016-01-01

    We present a bidirectional neural interface with a 4-channel biopotential analog-to-digital converter (bioADC) and a 4-channel current-mode stimulator in 180nm CMOS. The bioADC directly transduces microvolt biopotentials into a digital representation without a voltage-amplification stage. Each bioADC channel comprises a continuous-time first-order ΔΣ modulator with a chopper-stabilized OTA input and current feedback, followed by a second-order comb-filter decimator with programmable oversampling ratio. Each stimulator channel contains two independent digital-to-analog converters for anodic and cathodic current generation. A shared calibration circuit matches the amplitude of the anodic and cathodic currents for charge balancing. Powered from a 1.5V supply, the analog and digital circuits in each recording channel draw on average 1.54 μA and 2.13 μA of supply current, respectively. The bioADCs achieve an SNR of 58 dB and a SFDR of >70 dB, for better than 9-b ENOB. Intracranial EEG recordings from an anesthetized rat are shown and compared to simultaneous recordings from a commercial reference system to validate performance in-vivo. Additionally, we demonstrate bidirectional operation by recording cardiac modulation induced through vagus nerve stimulation, and closed-loop control of cardiac rhythm. The micropower operation, direct digital readout, and integration of electrical stimulation circuits make this interface ideally suited for closed-loop neuromodulation applications. PMID:27845676

  12. Whole-genome transcription and DNA methylation analysis of peripheral blood mononuclear cells identified aberrant gene regulation pathways in systemic lupus erythematosus.

    PubMed

    Zhu, Honglin; Mi, Wentao; Luo, Hui; Chen, Tao; Liu, Shengxi; Raman, Indu; Zuo, Xiaoxia; Li, Quan-Zhen

    2016-07-13

    Recent achievement in genetics and epigenetics has led to the exploration of the pathogenesis of systemic lupus erythematosus (SLE). Identification of differentially expressed genes and their regulatory mechanism(s) at whole-genome level will provide a comprehensive understanding of the development of SLE and its devastating complications, lupus nephritis (LN). We performed whole-genome transcription and DNA methylation analysis in PBMC of 30 SLE patients, including 15 with LN (SLE LN(+)) and 15 without LN (SLE LN(-)), and 25 normal controls (NC) using HumanHT-12 Beadchips and Illumina Human Methy450 chips. The serum proinflammatory cytokines were quantified using Bio-plex Human Cytokine 27-plex assay. Differentially expressed genes and differentially methylated CpG were analyzed with GenomeStudio, R, and SAM software. The association between DNA methylation and gene expression were tested. Gene interaction pathways of the differentially expressed genes were analyzed by IPA software. We identified 552 upregulated genes and 550 downregulated genes in PBMC of SLE. Integration of DNA methylation and gene expression profiling showed that 334 upregulated genes were hypomethylated, and 479 downregulated genes were hypermethylated. Pathway analysis on the differential genes in SLE revealed significant enrichment in interferon (IFN) signaling and toll-like receptor (TLR) signaling pathways. Nine IFN- and seven TLR-related genes were identified and displayed step-wise increase in SLE LN(-) and SLE LN(+). Hypomethylated CpG sites were detected on these genes. The gene expressions for MX1, GPR84, and E2F2 were increased in SLE LN(+) as compared to SLE LN(-) patients. The serum levels of inflammatory cytokines, including IL17A, IP-10, bFGF, TNF-α, IL-6, IL-15, GM-CSF, IL-1RA, IL-5, and IL-12p70, were significantly elevated in SLE compared with NC. The levels of IL-15 and IL1RA correlated with their mRNA expression. The upregulation of IL-15 may be regulated by hypomethylated CpG sites in the promotor region of the gene. Our study has demonstrated that significant number of differential genes in SLE were involved in IFN, TLR signaling pathways, and inflammatory cytokines. The enrichment of differential genes has been associated with aberrant DNA methylation, which may be relevant to the pathogenesis of SLE. Our observations have laid the groundwork for further diagnostic and mechanistic studies of SLE and LN.

  13. Quantitative, multiplexed workflow for deep analysis of human blood plasma and biomarker discovery by mass spectrometry.

    PubMed

    Keshishian, Hasmik; Burgess, Michael W; Specht, Harrison; Wallace, Luke; Clauser, Karl R; Gillette, Michael A; Carr, Steven A

    2017-08-01

    Proteomic characterization of blood plasma is of central importance to clinical proteomics and particularly to biomarker discovery studies. The vast dynamic range and high complexity of the plasma proteome have, however, proven to be serious challenges and have often led to unacceptable tradeoffs between depth of coverage and sample throughput. We present an optimized sample-processing pipeline for analysis of the human plasma proteome that provides greatly increased depth of detection, improved quantitative precision and much higher sample analysis throughput as compared with prior methods. The process includes abundant protein depletion, isobaric labeling at the peptide level for multiplexed relative quantification and ultra-high-performance liquid chromatography coupled to accurate-mass, high-resolution tandem mass spectrometry analysis of peptides fractionated off-line by basic pH reversed-phase (bRP) chromatography. The overall reproducibility of the process, including immunoaffinity depletion, is high, with a process replicate coefficient of variation (CV) of <12%. Using isobaric tags for relative and absolute quantitation (iTRAQ) 4-plex, >4,500 proteins are detected and quantified per patient sample on average, with two or more peptides per protein and starting from as little as 200 μl of plasma. The approach can be multiplexed up to 10-plex using tandem mass tags (TMT) reagents, further increasing throughput, albeit with some decrease in the number of proteins quantified. In addition, we provide a rapid protocol for analysis of nonfractionated depleted plasma samples analyzed in 10-plex. This provides ∼600 quantified proteins for each of the ten samples in ∼5 h of instrument time.

  14. Image sensor system with bio-inspired efficient coding and adaptation.

    PubMed

    Okuno, Hirotsugu; Yagi, Tetsuya

    2012-08-01

    We designed and implemented an image sensor system equipped with three bio-inspired coding and adaptation strategies: logarithmic transform, local average subtraction, and feedback gain control. The system comprises a field-programmable gate array (FPGA), a resistive network, and active pixel sensors (APS), whose light intensity-voltage characteristics are controllable. The system employs multiple time-varying reset voltage signals for APS in order to realize multiple logarithmic intensity-voltage characteristics, which are controlled so that the entropy of the output image is maximized. The system also employs local average subtraction and gain control in order to obtain images with an appropriate contrast. The local average is calculated by the resistive network instantaneously. The designed system was successfully used to obtain appropriate images of objects that were subjected to large changes in illumination.

  15. Propolis: A natural biomaterial for dental and oral healthcare

    PubMed Central

    Khurshid, Zohaib; Naseem, Mustafa; Najeeb, Shariq; Zohaib, Sana

    2017-01-01

    The field of health has always emphasised on the use of natural products for curing diseases. There are varieties of natural products (such as silk, herbal tea, chitosan) used today in the biomedical application in treating a large array of systemic diseases. The natural product "Propolis" is a non-toxic resinous material having beneficial properties such as antimicrobial, anticancer, antifungal, antiviral and anti-inflammatory; hence gain the attention of researchers for its potential for bio-dental applications. The study aims to explore the properties and chemistry of propolis concerning biomedical and dental applications. In addition, status and scope of propolis for current and potential future in bio-dental applications have been discussed. This review gives an insight to the reader about the possible use of propolis in modern-day dentistry. PMID:29354255

  16. Phosphoketolase pathway engineering for carbon-efficient biocatalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henard, Calvin Andrew; Freed, Emily Frances; Guarnieri, Michael Thomas

    2015-12-01

    Recent advances in metabolic engineering have facilitated the development of microbial biocatalysts capable of producing an array of bio-products, ranging from fuels to drug molecules. These bio-products are commonly generated through an acetyl-CoA intermediate, which serves as a key precursor in the biological conversion of carbon substrates. Moreover, conventional biocatalytic upgrading strategies proceeding through this route are limited by low carbon efficiencies, in large part due to carbon losses associated with pyruvate decarboxylation to acetyl-CoA. Bypass of pyruvate decarboxylation offers a means to dramatically enhance carbon yields and, in turn, bioprocess economics. Here, we discuss recent advances and prospects formore » employing the phosphoketolase pathway for direct biosynthesis of acetyl-CoA from carbon substrates, and phosphoketolase-based metabolic engineering strategies for carbon efficient biocatalysis.« less

  17. SELDI-TOF-MS ProteinChip array profiling of T-cell clones propagated in long-term culture identifies human profilin-1 as a potential bio-marker of immunosenescence.

    PubMed

    Mazzatti, Dawn J; Pawelec, Graham; Longdin, Robin; Powell, Jonathan R; Forsey, Rosalyn J

    2007-06-05

    The adaptive immune response requires waves of T-cell clonal expansion on contact with pathogen and elimination after clearance of the source of antigen. However, lifelong persistent infections with common viruses cause chronic antigenic stimulation which takes its toll on adaptive immunity in late life. Chronic antigenic stress results in deregulation of the T-cell response and accumulation of anergic cells. Longitudinal studies of the elderly show that this impacts on survival. Identifying the nature of the defects in chronically-stimulated T-cells and protein bio-markers of these dysfunctional cells would help to understand age-associated compromised T-cell function (immunosenescence) and facilitate the development of targeted intervention strategies.The purpose of this work was to use surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) to analyse proteins associated with T-cell senescence in order to identify potential bio-markers. Clonal populations of T-cells isolated from elderly octogenarian and centenarian donors were grown in vitro until senescence, and early passage and late passage (pre-senescent) cells were analysed using SELDI-TOF-MS ProteinChip arrays. Discriminant analysis identified several protein or peptide peaks in the region of 14.5-16.5 kDa that were associated with T-cell clone senescence. Human profilin-1, a ubiquitous protein associated with actin remodelling and cellular motility was unambiguously identified. Altered expression of profilin-1 in senescent T-cell clones was confirmed by Western blot analysis. Due to the proposed roles of profilin-1 in cellular survival, cytoskeleton remodelling, motility, and proliferation, it is hypothesised that differential expression of profilin-1 in ageing may contribute directly to immunosenescence.

  18. Identification of Skeletal Remains of Communist Armed Forces Victims During and After World War II: Combined Y-chromosome Short Tandem Repeat (STR) and MiniSTR Approach

    PubMed Central

    Marjanović, Damir; Durmić-Pašić, Adaleta; Kovačević, Lejla; Avdić, Jasna; Džehverović, Mirela; Haverić, Sanin; Ramić, Jasmin; Kalamujić, Belma; Bilela, Lada Lukić; Škaro, Vedrana; Projić, Petar; Bajrović, Kasim; Drobnič, Katja; Davoren, Jon; Primorac, Dragan

    2009-01-01

    Aim To report on the use of STR, Y-STRs, and miniSTRs typing methods in the identification of victims of revolutionary violence and crimes against humanity committed by the Communist Armed Forces during and after World War II in which bodies were exhumed from mass and individual graves in Slovenia. Methods Bone fragments and teeth were removed from human remains found in several small and closely located hidden mass graves in the Škofja Loka area (Lovrenska Grapa and Žolšče) and 2 individual graves in the Ljubljana area (Podlipoglav), Slovenia. DNA was isolated using the Qiagen DNA extraction procedure optimized for bone and teeth. Some DNA extracts required additional purification, such as N-buthanol treatment. The QuantifilerTM Human DNA Quantification Kit was used for DNA quantification. Initially, PowerPlex 16 kit was used to simultaneously analyze 15 short tandem repeat (STR) loci. The PowerPlex S5 miniSTR kit and AmpFℓSTR® MiniFiler PCR Amplification Kit was used for additional analysis if preliminary analysis yielded weak partial or no profiles at all. In 2 cases, when the PowerPlex 16 profiles indicated possible relatedness of the remains with reference samples, but there were insufficient probabilities to call the match to possible male paternal relatives, we resorted to an additional analysis of Y-STR markers. PowerPlex® Y System was used to simultaneously amplify 12 Y-STR loci. Fragment analysis was performed on an ABI PRISM 310 genetic analyzer. Matching probabilities were estimated using the DNA-View software. Results Following the Y-STR analysis, 1 of the “weak matches” previously obtained based on autosomal loci, was confirmed while the other 1 was not. Combined standard STR and miniSTR approach applied to bone samples from 2 individual graves resulted in positive identifications. Finally, using the same approach on 11 bone samples from hidden mass grave Žološče, we were able to obtain 6 useful DNA profiles. Conclusion The results of this study, in combination with previously obtained results, demonstrate that Y-chromosome testing and miniSTR methodology can contribute to the identification of human remains of victims of revolutionary violence from World War II. PMID:19480024

  19. Code-modulated interferometric imaging system using phased arrays

    NASA Astrophysics Data System (ADS)

    Chauhan, Vikas; Greene, Kevin; Floyd, Brian

    2016-05-01

    Millimeter-wave (mm-wave) imaging provides compelling capabilities for security screening, navigation, and bio- medical applications. Traditional scanned or focal-plane mm-wave imagers are bulky and costly. In contrast, phased-array hardware developed for mass-market wireless communications and automotive radar promise to be extremely low cost. In this work, we present techniques which can allow low-cost phased-array receivers to be reconfigured or re-purposed as interferometric imagers, removing the need for custom hardware and thereby reducing cost. Since traditional phased arrays power combine incoming signals prior to digitization, orthogonal code-modulation is applied to each incoming signal using phase shifters within each front-end and two-bit codes. These code-modulated signals can then be combined and processed coherently through a shared hardware path. Once digitized, visibility functions can be recovered through squaring and code-demultiplexing operations. Pro- vided that codes are selected such that the product of two orthogonal codes is a third unique and orthogonal code, it is possible to demultiplex complex visibility functions directly. As such, the proposed system modulates incoming signals but demodulates desired correlations. In this work, we present the operation of the system, a validation of its operation using behavioral models of a traditional phased array, and a benchmarking of the code-modulated interferometer against traditional interferometer and focal-plane arrays.

  20. Method for culturing mammalian cells in a perfused bioreactor

    NASA Technical Reports Server (NTRS)

    Schwarz, Ray P. (Inventor); Wolf, David A. (Inventor)

    1992-01-01

    A bio-reactor system wherein a tubular housing contains an internal circularly disposed set of blade members and a central tubular filter all mounted for rotation about a common horizontal axis and each having independent rotational support and rotational drive mechanisms. The housing, blade members and filter preferably are driven at a constant slow speed for placing a fluid culture medium with discrete microbeads and cell cultures in a discrete spatial suspension in the housing. Replacement fluid medium is symmetrically input and fluid medium is symmetrically output from the housing where the input and the output are part of a loop providing a constant or intermittent flow of fluid medium in a closed loop.

  1. Inhibition of 2,4-dichlorophenoxyacetic acid-stimulated elongation of pea stem segments by a xyloglucan oligosaccharide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    York, W.S.; Darvill, A.G.; Albersheim, P.

    1984-06-01

    Xyloglucan, isolated from the soluble extracellular polysaccharides of suspension-cultured sycamore (Acer pseudoplatanus) cells, was digested with an endo-..beta..-1,4-glucanase purified from the culture fluid of Trichoderma viride. A nonasaccharide-rich Bio-Gel P-2 fraction of this digest inhibited 2,4-dichlorophenoxyacetic-acid-stimulated elongation of etiolated pea stem segments. The inhibitory activity of this oligosaccharide fraction exhibited a well-define concentraction optimum between 10/sup -2/ and 10/sup -1/ micrograms per milliliter. Another fraction of the same xyloglucan digest, rich in a structurally related heptasaccharide, did not, at similar concentrations, significantly inhibit the elongation. 11 references, 3 figures.

  2. Rotating bio-reactor cell culture apparatus

    NASA Technical Reports Server (NTRS)

    Schwarz, Ray P. (Inventor); Wolf, David A. (Inventor)

    1991-01-01

    A bioreactor system is described in which a tubular housing contains an internal circularly disposed set of blade members and a central tubular filter all mounted for rotation about a common horizontal axis and each having independent rotational support and rotational drive mechanisms. The housing, blade members and filter preferably are driven at a constant slow speed for placing a fluid culture medium with discrete microbeads and cell cultures in a discrete spatial suspension in the housing. Replacement fluid medium is symmetrically input and fluid medium is symmetrically output from the housing where the input and the output are part of a loop providing a constant or intermittent flow of fluid medium in a closed loop.

  3. LC-lens array with light field algorithm for 3D biomedical applications

    NASA Astrophysics Data System (ADS)

    Huang, Yi-Pai; Hsieh, Po-Yuan; Hassanfiroozi, Amir; Martinez, Manuel; Javidi, Bahram; Chu, Chao-Yu; Hsuan, Yun; Chu, Wen-Chun

    2016-03-01

    In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.

  4. Flexible corner cube retroreflector array for temperature and strain sensing† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7ra13284k

    PubMed Central

    Khalid, Muhammad Waqas; Ahmed, Rajib; Yetisen, Ali K.

    2018-01-01

    Optical sensors for detecting temperature and strain play a crucial role in the analysis of environmental conditions and real-time remote sensing. However, the development of a single optical device that can sense temperature and strain simultaneously remains a challenge. Here, a flexible corner cube retroreflector (CCR) array based on passive dual optical sensing (temperature and strain) is demonstrated. A mechanical embossing process was utilised to replicate a three-dimensional (3D) CCR array in a soft flexible polymer film. The fabricated flexible CCR array samples were experimentally characterised through reflection measurements followed by computational modelling. As fabricated samples were illuminated with a monochromatic laser beam (635, 532, and 450 nm), a triangular shape reflection was obtained at the far-field. The fabricated flexible CCR array samples tuned retroreflected light based on external stimuli (temperature and strain as an applied force). For strain and temperature sensing, an applied force and temperature, in the form of weight suspension, and heat flow was applied to alter the replicated CCR surface structure, which in turn changed its optical response. Directional reflection from the heated flexible CCR array surface was also measured with tilt angle variation (max. up to 10°). Soft polymer CCRs may have potential in remote sensing applications, including measuring the temperature in space and in nuclear power stations. PMID:29568510

  5. LED array designing and its bactericidal effect researching on Pseudomonas aeruginosa in vitro

    NASA Astrophysics Data System (ADS)

    Fang, Jing; Xing, Jin; Gao, Liucun; Shen, Benjian; Kang, Hongxiang; Jie, Liang; Peng, Chen

    2015-10-01

    Lights with some special waveband and output power density have a bactericidal effect to some special bacteria. In this paper, the bactericidal effect of light at wavelength of 470 nm on P. aeruginosa (ATCC 27853) is researched with different irradiation dose. The light source is a LED array which is obtained by incoherent combine of 36 LEDs with emitting wavelength of 470 nm. The P. aeruginosa suspension is exposed with the LED array at the light power density of 100 mW/cm2 with exposures time of 0, 5, 10, 20, 40, and 80 min, respectively. The numbers of CFU are then determined by serial dilutions on LB agar plates. The bactericidal effect research results of 470 nm LED on P. aeruginosa show that the killing ratio increases with increasing of the exposure time. For the 80 min irradiation, as much as 92.4% reduction of P. aeruginosa is achieved. The results indicate that, in vitro, 470-nm lights produce dose dependent bactericidal effects on P. aeruginosa.

  6. Tunable Nanowire Patterning Using Standing Surface Acoustic Waves

    PubMed Central

    Chen, Yuchao; Ding, Xiaoyun; Lin, Sz-Chin Steven; Yang, Shikuan; Huang, Po-Hsun; Nama, Nitesh; Zhao, Yanhui; Nawaz, Ahmad Ahsan; Guo, Feng; Wang, Wei; Gu, Yeyi; Mallouk, Thomas E.; Huang, Tony Jun

    2014-01-01

    Patterning of nanowires in a controllable, tunable manner is important for the fabrication of functional nanodevices. Here we present a simple approach for tunable nanowire patterning using standing surface acoustic waves (SSAW). This technique allows for the construction of large-scale nanowire arrays with well-controlled patterning geometry and spacing within 5 seconds. In this approach, SSAWs were generated by interdigital transducers (IDTs), which induced a periodic alternating current (AC) electric field on the piezoelectric substrate and consequently patterned metallic nanowires in suspension. The patterns could be deposited onto the substrate after the liquid evaporated. By controlling the distribution of the SSAW field, metallic nanowires were assembled into different patterns including parallel and perpendicular arrays. The spacing of the nanowire arrays could be tuned by controlling the frequency of the surface acoustic waves. Additionally, we observed 3D spark-shape nanowire patterns in the SSAW field. The SSAW-based nanowire-patterning technique presented here possesses several advantages over alternative patterning approaches, including high versatility, tunability, and efficiency, making it promising for device applications. PMID:23540330

  7. The DNA Data Bank of Japan launches a new resource, the DDBJ Omics Archive of functional genomics experiments.

    PubMed

    Kodama, Yuichi; Mashima, Jun; Kaminuma, Eli; Gojobori, Takashi; Ogasawara, Osamu; Takagi, Toshihisa; Okubo, Kousaku; Nakamura, Yasukazu

    2012-01-01

    The DNA Data Bank of Japan (DDBJ; http://www.ddbj.nig.ac.jp) maintains and provides archival, retrieval and analytical resources for biological information. The central DDBJ resource consists of public, open-access nucleotide sequence databases including raw sequence reads, assembly information and functional annotation. Database content is exchanged with EBI and NCBI within the framework of the International Nucleotide Sequence Database Collaboration (INSDC). In 2011, DDBJ launched two new resources: the 'DDBJ Omics Archive' (DOR; http://trace.ddbj.nig.ac.jp/dor) and BioProject (http://trace.ddbj.nig.ac.jp/bioproject). DOR is an archival database of functional genomics data generated by microarray and highly parallel new generation sequencers. Data are exchanged between the ArrayExpress at EBI and DOR in the common MAGE-TAB format. BioProject provides an organizational framework to access metadata about research projects and the data from the projects that are deposited into different databases. In this article, we describe major changes and improvements introduced to the DDBJ services, and the launch of two new resources: DOR and BioProject.

  8. Experimental Data Extraction and in Silico Prediction of the Estrogenic Activity of Renewable Replacements for Bisphenol A

    PubMed Central

    Hong, Huixiao; Harvey, Benjamin G.; Palmese, Giuseppe R.; Stanzione, Joseph F.; Ng, Hui Wen; Sakkiah, Sugunadevi; Tong, Weida; Sadler, Joshua M.

    2016-01-01

    Bisphenol A (BPA) is a ubiquitous compound used in polymer manufacturing for a wide array of applications; however, increasing evidence has shown that BPA causes significant endocrine disruption and this has raised public concerns over safety and exposure limits. The use of renewable materials as polymer feedstocks provides an opportunity to develop replacement compounds for BPA that are sustainable and exhibit unique properties due to their diverse structures. As new bio-based materials are developed and tested, it is important to consider the impacts of both monomers and polymers on human health. Molecular docking simulations using the Estrogenic Activity Database in conjunction with the decision forest were performed as part of a two-tier in silico model to predict the activity of 29 bio-based platform chemicals in the estrogen receptor-α (ERα). Fifteen of the candidates were predicted as ER binders and fifteen as non-binders. Gaining insight into the estrogenic activity of the bio-based BPA replacements aids in the sustainable development of new polymeric materials. PMID:27420082

  9. Microfluidic liquid-air dual-gradient chip for synergic effect bio-evaluation of air pollutant.

    PubMed

    Liu, Xian-Jun; Hu, Shan-Wen; Xu, Bi-Yi; Zhao, Ge; Li, Xiang; Xie, Fu-Wei; Xu, Jing-Juan; Chen, Hong-Yuan

    2018-05-15

    In this paper, a novel prototype liquid-air dual gradient chip is introduced, which has paved the way for effective synergic effect bio-evaluation of air pollutant. The chip is composed of an array of the agarose liquid-air interfaces, top air gradient layer and bottom liquid gradient layer. The novel agarose liquid-air interface allows for non-biased exposure of cells to all the substances in the air and diffusive interactions with the liquid phase; while the dual liquid-air gradient provides powerful screening abilities, which well reduced errors, saved time and cost from repeated experiment. Coupling the two functions, the chip subsequently facilitates synergic effect evaluation of both liquid and air factors on cells. Here cigarette smoke was taken as the model air pollutant, and its strong synergic effects with inflammatory level of A549 lung cancer cells on their fate were successfully quantified for the first time. These results well testified that the proposed dual-gradient chip is powerful and indispensable for bio-evaluation of air pollutant. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Room Temperature Operable Autonomously Moving Bio-Microrobot Powered by Insect Dorsal Vessel Tissue

    PubMed Central

    Akiyama, Yoshitake; Hoshino, Takayuki; Iwabuchi, Kikuo; Morishima, Keisuke

    2012-01-01

    Living muscle tissues and cells have been attracting attention as potential actuator candidates. In particular, insect dorsal vessel tissue (DVT) seems to be well suited for a bio-actuator since it is capable of contracting autonomously and the tissue itself and its cells are more environmentally robust under culturing conditions compared with mammalian tissues and cells. Here we demonstrate an autonomously moving polypod microrobot (PMR) powered by DVT excised from an inchworm. We fabricated a prototype of the PMR by assembling a whole DVT onto an inverted two-row micropillar array. The prototype moved autonomously at a velocity of 3.5×10−2 µm/s, and the contracting force of the whole DVT was calculated as 20 µN. Based on the results obtained by the prototype, we then designed and fabricated an actual PMR. We were able to increase the velocity significantly for the actual PMR which could move autonomously at a velocity of 3.5 µm/s. These results indicate that insect DVT has sufficient potential as the driving force for a bio-microrobot that can be utilized in microspaces. PMID:22808004

  11. Microintaglio Printing for Soft Lithography-Based in Situ Microarrays

    PubMed Central

    Biyani, Manish; Ichiki, Takanori

    2015-01-01

    Advances in lithographic approaches to fabricating bio-microarrays have been extensively explored over the last two decades. However, the need for pattern flexibility, a high density, a high resolution, affordability and on-demand fabrication is promoting the development of unconventional routes for microarray fabrication. This review highlights the development and uses of a new molecular lithography approach, called “microintaglio printing technology”, for large-scale bio-microarray fabrication using a microreactor array (µRA)-based chip consisting of uniformly-arranged, femtoliter-size µRA molds. In this method, a single-molecule-amplified DNA microarray pattern is self-assembled onto a µRA mold and subsequently converted into a messenger RNA or protein microarray pattern by simultaneously producing and transferring (immobilizing) a messenger RNA or a protein from a µRA mold to a glass surface. Microintaglio printing allows the self-assembly and patterning of in situ-synthesized biomolecules into high-density (kilo-giga-density), ordered arrays on a chip surface with µm-order precision. This holistic aim, which is difficult to achieve using conventional printing and microarray approaches, is expected to revolutionize and reshape proteomics. This review is not written comprehensively, but rather substantively, highlighting the versatility of microintaglio printing for developing a prerequisite platform for microarray technology for the postgenomic era. PMID:27600226

  12. High-density, microsphere-based fiber optic DNA microarrays.

    PubMed

    Epstein, Jason R; Leung, Amy P K; Lee, Kyong Hoon; Walt, David R

    2003-05-01

    A high-density fiber optic DNA microarray has been developed consisting of oligonucleotide-functionalized, 3.1-microm-diameter microspheres randomly distributed on the etched face of an imaging fiber bundle. The fiber bundles are comprised of 6000-50000 fused optical fibers and each fiber terminates with an etched well. The microwell array is capable of housing complementary-sized microspheres, each containing thousands of copies of a unique oligonucleotide probe sequence. The array fabrication process results in random microsphere placement. Determining the position of microspheres in the random array requires an optical encoding scheme. This array platform provides many advantages over other array formats. The microsphere-stock suspension concentration added to the etched fiber can be controlled to provide inherent sensor redundancy. Examining identical microspheres has a beneficial effect on the signal-to-noise ratio. As other sequences of interest are discovered, new microsphere sensing elements can be added to existing microsphere pools and new arrays can be fabricated incorporating the new sequences without altering the existing detection capabilities. These microarrays contain the smallest feature sizes (3 microm) of any DNA array, allowing interrogation of extremely small sample volumes. Reducing the feature size results in higher local target molecule concentrations, creating rapid and highly sensitive assays. The microsphere array platform is also flexible in its applications; research has included DNA-protein interaction profiles, microbial strain differentiation, and non-labeled target interrogation with molecular beacons. Fiber optic microsphere-based DNA microarrays have a simple fabrication protocol enabling their expansion into other applications, such as single cell-based assays.

  13. A Versatile Method of Patterning Proteins and Cells.

    PubMed

    Shrirao, Anil B; Kung, Frank H; Yip, Derek; Firestein, Bonnie L; Cho, Cheul H; Townes-Anderson, Ellen

    2017-02-26

    Substrate and cell patterning techniques are widely used in cell biology to study cell-to-cell and cell-to-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This article describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. This method enables researchers to pattern multiple substrates including fibronectin, collagen, antibodies (Sal-1), poly-D-lysine (PDL), and laminin. Patterning of substrates allows one to indirectly pattern a variety of cells. We have tested C2C12 myoblasts, the PC12 neuronal cell line, embryonic rat cortical neurons, and amphibian retinal neurons. In addition, we demonstrate that this technique can directly pattern fibroblasts in microfluidic channels via brief application of a low vacuum on cell suspensions. The low vacuum does not significantly decrease cell viability as shown by cell viability assays. Modifications are discussed for application of the method to different cell and substrate types. This technique allows researchers to pattern cells and proteins in specific patterns without the need for exotic materials or equipment and can be done in any laboratory with a vacuum.

  14. Conformally encapsulated multi-electrode arrays with seamless insulation

    DOEpatents

    Tabada, Phillipe J.; Shah, Kedar G.; Tolosa, Vanessa; Pannu, Satinderall S.; Tooker, Angela; Delima, Terri; Sheth, Heeral; Felix, Sarah

    2016-11-22

    Thin-film multi-electrode arrays (MEA) having one or more electrically conductive beams conformally encapsulated in a seamless block of electrically insulating material, and methods of fabricating such MEAs using reproducible, microfabrication processes. One or more electrically conductive traces are formed on scaffold material that is subsequently removed to suspend the traces over a substrate by support portions of the trace beam in contact with the substrate. By encapsulating the suspended traces, either individually or together, with a single continuous layer of an electrically insulating material, a seamless block of electrically insulating material is formed that conforms to the shape of the trace beam structure, including any trace backings which provide suspension support. Electrical contacts, electrodes, or leads of the traces are exposed from the encapsulated trace beam structure by removing the substrate.

  15. CEBS object model for systems biology data, SysBio-OM.

    PubMed

    Xirasagar, Sandhya; Gustafson, Scott; Merrick, B Alex; Tomer, Kenneth B; Stasiewicz, Stanley; Chan, Denny D; Yost, Kenneth J; Yates, John R; Sumner, Susan; Xiao, Nianqing; Waters, Michael D

    2004-09-01

    To promote a systems biology approach to understanding the biological effects of environmental stressors, the Chemical Effects in Biological Systems (CEBS) knowledge base is being developed to house data from multiple complex data streams in a systems friendly manner that will accommodate extensive querying from users. Unified data representation via a single object model will greatly aid in integrating data storage and management, and facilitate reuse of software to analyze and display data resulting from diverse differential expression or differential profile technologies. Data streams include, but are not limited to, gene expression analysis (transcriptomics), protein expression and protein-protein interaction analysis (proteomics) and changes in low molecular weight metabolite levels (metabolomics). To enable the integration of microarray gene expression, proteomics and metabolomics data in the CEBS system, we designed an object model, Systems Biology Object Model (SysBio-OM). The model is comprehensive and leverages other open source efforts, namely the MicroArray Gene Expression Object Model (MAGE-OM) and the Proteomics Experiment Data Repository (PEDRo) object model. SysBio-OM is designed by extending MAGE-OM to represent protein expression data elements (including those from PEDRo), protein-protein interaction and metabolomics data. SysBio-OM promotes the standardization of data representation and data quality by facilitating the capture of the minimum annotation required for an experiment. Such standardization refines the accuracy of data mining and interpretation. The open source SysBio-OM model, which can be implemented on varied computing platforms is presented here. A universal modeling language depiction of the entire SysBio-OM is available at http://cebs.niehs.nih.gov/SysBioOM/. The Rational Rose object model package is distributed under an open source license that permits unrestricted academic and commercial use and is available at http://cebs.niehs.nih.gov/cebsdownloads. The database and interface are being built to implement the model and will be available for public use at http://cebs.niehs.nih.gov.

  16. A force sensor using nanowire arrays to understand biofilm formation (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Sahoo, Prasana K.; Cavalli, Alessandro; Pelegati, Vitor B.; Murillo, Duber M.; Souza, Alessandra A.; Cesar, Carlos L.; Bakkers, Erik P. A. M.; Cotta, Monica A.

    2016-03-01

    Understanding the cellular signaling and function at the nano-bio interface can pave the way towards developing next-generation smart diagnostic tools. From this perspective, limited reports detail so far the cellular and subcellular forces exerted by bacterial cells during the interaction with abiotic materials. Nanowire arrays with high aspect ratio have been used to detect such small forces. In this regard, live force measurements were performed ex-vivo during the interaction of Xylella fastidiosa bacterial cells with InP nanowire arrays. The influence of nanowire array topography and surface chemistry on the response and motion of bacterial cells was studied in detail. The nanowire arrays were also functionalized with different cell adhesive promoters, such as amines and XadA1, an afimbrial protein of X.fastidiosa. By employing the well-defined InP nanowire arrays platform, and single cell confocal imaging system, we were able to trace the bacterial growth pattern, and show that their initial attachment locations are strongly influenced by the surface chemistry and nanoscale surface topography. In addition, we measure the cellular forces down to few nanonewton range using these nanowire arrays. In case of nanowire functionalized with XadA1, the force exerted by vertically and horizontally attached single bacteria on the nanowire is in average 14% and 26% higher than for the pristine array, respectively. These results provide an excellent basis for live-cell force measurements as well as unravel the range of forces involved during the early stages of bacterial adhesion and biofilm formation.

  17. Development and testing of bio-inspired microelectromechanical pressure sensor arrays for increased situational awareness for marine vehicles

    NASA Astrophysics Data System (ADS)

    Dusek, J.; Kottapalli, A. G. P.; Woo, M. E.; Asadnia, M.; Miao, J.; Lang, J. H.; Triantafyllou, M. S.

    2013-01-01

    The lateral line found on most species of fish is a sensory organ without analog in humans. Using sensory feedback from the lateral line, fish are able to track prey, school, avoid obstacles, and detect vortical flow structures. Composed of both a superficial component, and a component contained within canals beneath the fish’s skin, the lateral line acts in a similar fashion to an array of differential pressure sensors. In an effort to enhance the situational and environmental awareness of marine vehicles, lateral-line-inspired pressure sensor arrays were developed to mimic the enhanced sensory capabilities observed in fish. Three flexible and waterproof pressure sensor arrays were fabricated for use as a surface-mounted ‘smart skin’ on marine vehicles. Two of the sensor arrays were based around the use of commercially available piezoresistive sensor dies, with innovative packaging schemes to allow for flexibility and underwater operation. The sensor arrays employed liquid crystal polymer and flexible printed circuit board substrates with metallic circuits and silicone encapsulation. The third sensor array employed a novel nanocomposite material set that allowed for the fabrication of a completely flexible sensor array. All three sensors were surface mounted on the curved hull of an autonomous kayak vehicle, and tested in both pool and reservoir environments. Results demonstrated that all three sensors were operational while deployed on the autonomous vehicle, and provided an accurate means for monitoring the vehicle dynamics.

  18. Efficacy of the FilmArray blood culture identification panel for direct molecular diagnosis of infectious diseases from samples other than blood.

    PubMed

    Micó, Miquel; Navarro, Ferran; de Miniac, Daniela; González, Yésica; Brell, Albert; López, Cristina; Sánchez-Reus, Ferran; Mirelis, Beatriz; Coll, Pere

    2015-12-01

    Molecular-based techniques reduce the delay in diagnosing infectious diseases and therefore contribute to better patient outcomes. We assessed the FilmArray blood culture identification (BCID) panel (Biofire Diagnostics/bioMérieux) directly on clinical specimens other than blood: cerebrospinal, joint, pleural and ascitic fluids, bronchoscopy samples and abscesses. We compared the results from 88 samples obtained by culture-based techniques. The percentage of agreement between the two methods was 75 % with a Cohen κ value of 0.51. Global sensitivity and specificity using the FilmArray BCID panel were 71 and 97 %, respectively. Sensitivity was poorer in samples with a low bacterial load, such as ascitic and pleural fluids (25 %), whereas the sensitivity for abscess samples was high (89 %). These findings suggest that the FilmArray BCID panel could be useful to perform microbiological diagnosis directly from samples other than positive blood cultures, as it offers acceptable sensitivity and moderate agreement with conventional microbiological methods. Nevertheless, cost-benefit studies should be performed before introducing this method into algorithms for microbiological diagnostics.

  19. Control of optical bandgap energy and optical absorption coefficient by geometric parameters in sub-10 nm silicon-nanodisc array structure

    NASA Astrophysics Data System (ADS)

    Fairuz Budiman, Mohd; Hu, Weiguo; Igarashi, Makoto; Tsukamoto, Rikako; Isoda, Taiga; Itoh, Kohei M.; Yamashita, Ichiro; Murayama, Akihiro; Okada, Yoshitaka; Samukawa, Seiji

    2012-02-01

    A sub-10 nm, high-density, periodic silicon-nanodisc (Si-ND) array has been fabricated using a new top-down process, which involves a 2D array bio-template etching mask made of Listeria-Dps with a 4.5 nm diameter iron oxide core and damage-free neutral-beam etching (Si-ND diameter: 6.4 nm). An Si-ND array with an SiO2 matrix demonstrated more controllable optical bandgap energy due to the fine tunability of the Si-ND thickness and diameter. Unlike the case of shrinking Si-ND thickness, the case of shrinking Si-ND diameter simultaneously increased the optical absorption coefficient and the optical bandgap energy. The optical absorption coefficient became higher due to the decrease in the center-to-center distance of NDs to enhance wavefunction coupling. This means that our 6 nm diameter Si-ND structure can satisfy the strict requirements of optical bandgap energy control and high absorption coefficient for achieving realistic Si quantum dot solar cells.

  20. Robotic Ankle for Omnidirectional Rock Anchors

    NASA Technical Reports Server (NTRS)

    Parness, Aaron; Frost, Matthew; Thatte, Nitish

    2013-01-01

    Future robotic exploration of near-Earth asteroids and the vertical and inverted rock walls of lava caves and cliff faces on Mars and other planetary bodies would require a method of gripping their rocky surfaces to allow mobility without gravitational assistance. In order to successfully navigate this terrain and drill for samples, the grippers must be able to produce anchoring forces in excess of 100 N. Additionally, the grippers must be able to support the inertial forces of a moving robot, as well gravitational forces for demonstrations on Earth. One possible solution would be to use microspine arrays to anchor to rock surfaces and provide the necessary load-bearing abilities for robotic exploration of asteroids. Microspine arrays comprise dozens of small steel hooks supported on individual suspensions. When these arrays are dragged along a rock surface, the steel hooks engage with asperities and holes on the surface. The suspensions allow for individual hooks to engage with asperities while the remaining hooks continue to drag along the surface. This ensures that the maximum possible number of hooks engage with the surface, thereby increasing the load-bearing abilities of the gripper. Using the microspine array grippers described above as the end-effectors of a robot would allow it to traverse terrain previously unreachable by traditional wheeled robots. Furthermore, microspine-gripping robots that can perch on cliffs or rocky walls could enable a new class of persistent surveillance devices for military applications. In order to interface these microspine grippers with a legged robot, an ankle is needed that can robotically actuate the gripper, as well as allow it to conform to the large-scale irregularities in the rock. The anchor serves three main purposes: deploy and release the anchor, conform to roughness or misalignment with the surface, and cancel out any moments about the anchor that could cause unintentional detachment. The ankle design contains a rotary DC motor that can drag the microspine arrays across the surface to engage them with asperities, as well as a linear actuator to disengage the hooks from the surface. Additionally, the ankle allows the gripper to rotate freely about all three axes so that when the robot takes a step, the gripper may optimally orient itself with respect to the wall or ground. Finally, the ankle contains some minimal elasticity, so that between steps, the gripper returns to a default position that is roughly parallel to the wall.

  1. Subchronic Toxicity of Copper Oxide Nanoparticles and Its Attenuation with the Help of a Combination of Bioprotectors

    PubMed Central

    Privalova, Larisa I.; Katsnelson, Boris A.; Loginova, Nadezhda V.; Gurvich, Vladimir B.; Shur, Vladimir Y.; Valamina, Irene E.; Makeyev, Oleg H.; Sutunkova, Marina P.; Minigalieva, Ilzira A.; Kireyeva, Ekaterina P.; Rusakov, Vadim O.; Tyurnina, Anastasia E.; Kozin, Roman V.; Meshtcheryakova, Ekaterina Y.; Korotkov, Artem V.; Shuman, Eugene A.; Zvereva, Anastasia E.; Kostykova, Svetlana V.

    2014-01-01

    In the copper metallurgy workplace air is polluted with condensation aerosols, which a significant fraction of is presented by copper oxide particles <100 nm. In the scientific literature, there is a lack of their in vivo toxicity characterization and virtually no attempts of enhancing organism’s resistance to their impact. A stable suspension of copper oxide particles with mean (±SD) diameter 20 ± 10 nm was prepared by laser ablation of pure copper in water. It was being injected intraperitoneally to rats at a dose of 10 mg/kg (0.5 mg per mL of deionized water) three times a week up to 19 injections. In parallel, another group of rats was so injected with the same suspension against the background of oral administration of a “bio-protective complex” (BPC) comprising pectin, a multivitamin-multimineral preparation, some amino acids and fish oil rich in ω-3 PUFA. After the termination of injections, many functional and biochemical indices for the organism’s status, as well as pathological changes of liver, spleen, kidneys, and brain microscopic structure were evaluated for signs of toxicity. In the same organs we have measured accumulation of copper while their cells were used for performing the Random Amplification of Polymorphic DNA (RAPD) test for DNA fragmentation. The same features were assessed in control rats infected intraperitoneally with water with or without administration of the BPC. The copper oxide nanoparticles proved adversely bio-active in all respects considered in this study, their active in vivo solubilization in biological fluids playing presumably an important role in both toxicokinetics and toxicodynamics. The BPC proposed and tested by us attenuated systemic and target organs toxicity, as well as genotoxicity of this substance. Judging by experimental data obtained in this investigation, occupational exposures to nano-scale copper oxide particles can present a significant health risk while the further search for its management with the help of innocuous bioprotectors seems to be justified. PMID:25026171

  2. Subchronic toxicity of copper oxide nanoparticles and its attenuation with the help of a combination of bioprotectors.

    PubMed

    Privalova, Larisa I; Katsnelson, Boris A; Loginova, Nadezhda V; Gurvich, Vladimir B; Shur, Vladimir Y; Valamina, Irene E; Makeyev, Oleg H; Sutunkova, Marina P; Minigalieva, Ilzira A; Kireyeva, Ekaterina P; Rusakov, Vadim O; Tyurnina, Anastasia E; Kozin, Roman V; Meshtcheryakova, Ekaterina Y; Korotkov, Artem V; Shuman, Eugene A; Zvereva, Anastasia E; Kostykova, Svetlana V

    2014-07-14

    In the copper metallurgy workplace air is polluted with condensation aerosols, which a significant fraction of is presented by copper oxide particles<100 nm. In the scientific literature, there is a lack of their in vivo toxicity characterization and virtually no attempts of enhancing organism's resistance to their impact. A stable suspension of copper oxide particles with mean (±SD) diameter 20±10 nm was prepared by laser ablation of pure copper in water. It was being injected intraperitoneally to rats at a dose of 10 mg/kg (0.5 mg per mL of deionized water) three times a week up to 19 injections. In parallel, another group of rats was so injected with the same suspension against the background of oral administration of a "bio-protective complex" (BPC) comprising pectin, a multivitamin-multimineral preparation, some amino acids and fish oil rich in ω-3 PUFA. After the termination of injections, many functional and biochemical indices for the organism's status, as well as pathological changes of liver, spleen, kidneys, and brain microscopic structure were evaluated for signs of toxicity. In the same organs we have measured accumulation of copper while their cells were used for performing the Random Amplification of Polymorphic DNA (RAPD) test for DNA fragmentation. The same features were assessed in control rats infected intraperitoneally with water with or without administration of the BPC. The copper oxide nanoparticles proved adversely bio-active in all respects considered in this study, their active in vivo solubilization in biological fluids playing presumably an important role in both toxicokinetics and toxicodynamics. The BPC proposed and tested by us attenuated systemic and target organs toxicity, as well as genotoxicity of this substance. Judging by experimental data obtained in this investigation, occupational exposures to nano-scale copper oxide particles can present a significant health risk while the further search for its management with the help of innocuous bioprotectors seems to be justified.

  3. Paper-based solid-phase multiplexed nucleic acid hybridization assay with tunable dynamic range using immobilized quantum dots as donors in fluorescence resonance energy transfer.

    PubMed

    Noor, M Omair; Krull, Ulrich J

    2013-08-06

    A multiplexed solid-phase nucleic acid hybridization assay on a paper-based platform is presented using multicolor immobilized quantum dots (QDs) as donors in fluorescence resonance energy transfer (FRET). The surface of paper was modified with imidazole groups to immobilize two types of QD-probe oligonucleotide conjugates that were assembled in solution. Green-emitting QDs (gQDs) and red-emitting QDs (rQDs) served as donors with Cy3 and Alexa Fluor 647 (A647) acceptors. The gQD/Cy3 FRET pair served as an internal standard, while the rQD/A647 FRET pair served as a detection channel, combining the control and analytical test zones in one physical location. Hybridization of dye-labeled oligonucleotide targets provided the proximity for FRET sensitized emission from the acceptor dyes, which served as an analytical signal. Hybridization assays in the multicolor format provided a limit of detection of 90 fmol and an upper limit of dynamic range of 3.5 pmol. The use of an array of detection zones was designed to provide improved analytical figures of merit compared to that which could be achieved on one type of array design in terms of relative concentration of multicolor QDs. The hybridization assays showed excellent resistance to nonspecific adsorption of oligonucleotides. Selectivity of the two-plex hybridization assay was demonstrated by single nucleotide polymorphism (SNP) detection at a contrast ratio of 50:1. Additionally, it is shown that the use of preformed QD-probe oligonucleotide conjugates and consideration of the relative number density of the two types of QD-probe conjugates in the two-color assay format is advantageous to maximize assay sensitivity and the upper limit of dynamic range.

  4. Geckoprinting: assembly of microelectronic devices on unconventional surfaces by transfer printing with isolated gecko setal arrays

    PubMed Central

    Jeong, Jaeyoung; Kim, Juho; Song, Kwangsun; Autumn, Kellar; Lee, Jongho

    2014-01-01

    Developing electronics in unconventional forms provides opportunities to expand the use of electronics in diverse applications including bio-integrated or implanted electronics. One of the key challenges lies in integrating semiconductor microdevices onto unconventional substrates without glue, high pressure or temperature that may cause damage to microdevices, substrates or interfaces. This paper describes a solution based on natural gecko setal arrays that switch adhesion mechanically on and off, enabling pick and place manipulation of thin microscale semiconductor materials onto diverse surfaces including plants and insects whose surfaces are usually rough and irregular. A demonstration of functional ‘geckoprinted’ microelectronic devices provides a proof of concept of our results in practical applications. PMID:25056216

  5. Synthesis of Polyhydroxybutyrate Particles with Micro-to-Nanosized Structures and Application as Protective Coating for Packaging Papers

    PubMed Central

    Rastogi, Vibhore Kumar; Samyn, Pieter

    2016-01-01

    This study reports on the development of bio-based hydrophobic coatings for packaging papers through deposition of polyhydroxybutyrate (PHB) particles in combination with nanofibrillated cellulose (NFC) and plant wax. In the first approach, PHB particles in the micrometer range (PHB-MP) were prepared through a phase-separation technique providing internally-nanosized structures. The particles were transferred as a coating by dip-coating filter papers in the particle suspension, followed by sizing with a carnauba wax solution. This approach allowed partial to almost full surface coverage of PHB-MP over the paper surface, resulting in static water contact angles of 105°–122° and 129°–144° after additional wax coating. In the second approach, PHB particles with submicron sizes (PHB-SP) were synthesized by an oil-in-water emulsion (o/w) solvent evaporation method and mixed in aqueous suspensions with 0–7 wt % NFC. After dip-coating filter papers in PHB-SP/NFC suspensions and sizing with a carnauba wax solution, static water contact angles of 112°–152° were obtained. The intrinsic properties of the particles were analyzed by scanning electron microscopy, thermal analysis and infrared spectroscopy, indicating higher crystallinity for PHB-SP than PHB-MP. The chemical interactions between the more amorphous PHB-MP particles and paper fibers were identified as an esterification reaction, while the morphology of the NFC fibrillar network was playing a key role as the binding agent in the retention of more crystalline PHB-SP at the paper surface, hence contributing to higher hydrophobicity. PMID:28336839

  6. Synthesis of Polyhydroxybutyrate Particles with Micro-to-Nanosized Structures and Application as Protective Coating for Packaging Papers.

    PubMed

    Rastogi, Vibhore Kumar; Samyn, Pieter

    2016-12-30

    This study reports on the development of bio-based hydrophobic coatings for packaging papers through deposition of polyhydroxybutyrate (PHB) particles in combination with nanofibrillated cellulose (NFC) and plant wax. In the first approach, PHB particles in the micrometer range (PHB-MP) were prepared through a phase-separation technique providing internally-nanosized structures. The particles were transferred as a coating by dip-coating filter papers in the particle suspension, followed by sizing with a carnauba wax solution. This approach allowed partial to almost full surface coverage of PHB-MP over the paper surface, resulting in static water contact angles of 105°-122° and 129°-144° after additional wax coating. In the second approach, PHB particles with submicron sizes (PHB-SP) were synthesized by an oil-in-water emulsion (o/w) solvent evaporation method and mixed in aqueous suspensions with 0-7 wt % NFC. After dip-coating filter papers in PHB-SP/NFC suspensions and sizing with a carnauba wax solution, static water contact angles of 112°-152° were obtained. The intrinsic properties of the particles were analyzed by scanning electron microscopy, thermal analysis and infrared spectroscopy, indicating higher crystallinity for PHB-SP than PHB-MP. The chemical interactions between the more amorphous PHB-MP particles and paper fibers were identified as an esterification reaction, while the morphology of the NFC fibrillar network was playing a key role as the binding agent in the retention of more crystalline PHB-SP at the paper surface, hence contributing to higher hydrophobicity.

  7. Formation and composition of adsorbates on hydrophobic carbon surfaces from aqueous laccase-maltodextrin mixture suspension

    NASA Astrophysics Data System (ADS)

    Corrales Ureña, Yendry Regina; Lisboa-Filho, Paulo Noronha; Szardenings, Michael; Gätjen, Linda; Noeske, Paul-Ludwig Michael; Rischka, Klaus

    2016-11-01

    A robust procedure for the surface bio-functionalization of carbon surfaces was developed. It consists on the modification of carbon materials in contact with an aqueous suspension of the enzyme laccase from Trametes versicolor and the lyophilization agent maltodextrin, with the pH value adjusted close to the isoelectric point of the enzyme. We report in-situ investigations applying Quartz Crystal Microbalance with Dissipation (QCM-D) for carbon-coated sensor surfaces and, moreover, ex-situ measurements with static contact angle measurements, X-ray Photoelectron Spectroscopy (XPS) and Scanning Force Microscopy (SFM) for smooth Highly Oriented Pyrolytic Graphite (HOPG) substrates, for contact times between the enzyme formulation and the carbon material surface ranging from 20 s to 24 h. QCM-D studies reveals the formation of rigid layer of biomaterial, a few nanometers thin, which shows a strongly improved wettability of the substrate surface upon contact angle measurements. Following spectroscopic characterization, these layers are composed of mixtures of laccase and maltodextrin. The formation of these adsorbates is attributed to attractive interactions between laccase, the maltodextrin-based lyophilization agent and the hydrophobic carbon surfaces; a short-term contact between the aqueous laccase mixture suspension and HOPG surfaces is shown to merely result in de-wetting patterns influencing the results of contact angle measurements. The new enzyme-based surface modification of carbon-based materials is suggested to be applicable for the improvement of not only the wettability of low energy substrate surfaces with fluid formulations like coatings or adhesives, but also their adhesion in contact with hardened polymers.

  8. A Low Power Cryogenic Shutter Mechanism for use in Infrared Images

    NASA Technical Reports Server (NTRS)

    Schwinger, D. Scott; Hakun, Claef F.

    2000-01-01

    This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

  9. In-air microfluidics enables rapid fabrication of emulsions, suspensions, and 3D modular (bio)materials

    PubMed Central

    Visser, Claas Willem; Kamperman, Tom; Karbaat, Lisanne P.; Lohse, Detlef; Karperien, Marcel

    2018-01-01

    Microfluidic chips provide unparalleled control over droplets and jets, which have advanced all natural sciences. However, microfluidic applications could be vastly expanded by increasing the per-channel throughput and directly exploiting the output of chips for rapid additive manufacturing. We unlock these features with in-air microfluidics, a new chip-free platform to manipulate microscale liquid streams in the air. By controlling the composition and in-air impact of liquid microjets by surface tension–driven encapsulation, we fabricate monodisperse emulsions, particles, and fibers with diameters of 20 to 300 μm at rates that are 10 to 100 times higher than chip-based droplet microfluidics. Furthermore, in-air microfluidics uniquely enables module-based production of three-dimensional (3D) multiscale (bio)materials in one step because droplets are partially solidified in-flight and can immediately be printed onto a substrate. In-air microfluidics is cytocompatible, as demonstrated by additive manufacturing of 3D modular constructs with tailored microenvironments for multiple cell types. Its in-line control, high throughput and resolution, and cytocompatibility make in-air microfluidics a versatile platform technology for science, industry, and health care. PMID:29399628

  10. Single-cell multiplexed cytokine profiling of CD19 CAR-T cells reveals a diverse landscape of polyfunctional antigen-specific response.

    PubMed

    Xue, Qiong; Bettini, Emily; Paczkowski, Patrick; Ng, Colin; Kaiser, Alaina; McConnell, Timothy; Kodrasi, Olja; Quigley, Máire F; Heath, James; Fan, Rong; Mackay, Sean; Dudley, Mark E; Kassim, Sadik H; Zhou, Jing

    2017-11-21

    It remains challenging to characterize the functional attributes of chimeric antigen receptor (CAR)-engineered T cell product targeting CD19 related to potency and immunotoxicity ex vivo, despite promising in vivo efficacy in patients with B cell malignancies. We employed a single-cell, 16-plex cytokine microfluidics device and new analysis techniques to evaluate the functional profile of CD19 CAR-T cells upon antigen-specific stimulation. CAR-T cells were manufactured from human PBMCs transfected with the lentivirus encoding the CD19-BB-z transgene and expanded with anti-CD3/anti-CD28 coated beads. The enriched CAR-T cells were stimulated with anti-CAR or control IgG beads, stained with anti-CD4 RPE and anti-CD8 Alexa Fluor 647 antibodies, and incubated for 16 h in a single-cell barcode chip (SCBC). Each SCBC contains ~12,000 microchambers, covered with a glass slide that was pre-patterned with a complete copy of a 16-plex antibody array. Protein secretions from single CAR-T cells were captured and subsequently analyzed using proprietary software and new visualization methods. We demonstrate a new method for single-cell profiling of CD19 CAR-T pre-infusion products prepared from 4 healthy donors. CAR-T single cells exhibited a marked heterogeneity of cytokine secretions and polyfunctional (2+ cytokine) subsets specific to anti-CAR bead stimulation. The breadth of responses includes anti-tumor effector (Granzyme B, IFN-γ, MIP-1α, TNF-α), stimulatory (GM-CSF, IL-2, IL-8), regulatory (IL-4, IL-13, IL-22), and inflammatory (IL-6, IL-17A) functions. Furthermore, we developed two new bioinformatics tools for more effective polyfunctional subset visualization and comparison between donors. Single-cell, multiplexed, proteomic profiling of CD19 CAR-T product reveals a diverse landscape of immune effector response of CD19 CAR-T cells to antigen-specific challenge, providing a new platform for capturing CAR-T product data for correlative analysis. Additionally, such high dimensional data requires new visualization methods to further define precise polyfunctional response differences in these products. The presented biomarker capture and analysis system provides a more sensitive and comprehensive functional assessment of CAR-T pre-infusion products and may provide insights into the safety and efficacy of CAR-T cell therapy.

  11. Bio-Inspired Controller on an FPGA Applied to Closed-Loop Diaphragmatic Stimulation

    PubMed Central

    Zbrzeski, Adeline; Bornat, Yannick; Hillen, Brian; Siu, Ricardo; Abbas, James; Jung, Ranu; Renaud, Sylvie

    2016-01-01

    Cervical spinal cord injury can disrupt connections between the brain respiratory network and the respiratory muscles which can lead to partial or complete loss of ventilatory control and require ventilatory assistance. Unlike current open-loop technology, a closed-loop diaphragmatic pacing system could overcome the drawbacks of manual titration as well as respond to changing ventilation requirements. We present an original bio-inspired assistive technology for real-time ventilation assistance, implemented in a digital configurable Field Programmable Gate Array (FPGA). The bio-inspired controller, which is a spiking neural network (SNN) inspired by the medullary respiratory network, is as robust as a classic controller while having a flexible, low-power and low-cost hardware design. The system was simulated in MATLAB with FPGA-specific constraints and tested with a computational model of rat breathing; the model reproduced experimentally collected respiratory data in eupneic animals. The open-loop version of the bio-inspired controller was implemented on the FPGA. Electrical test bench characterizations confirmed the system functionality. Open and closed-loop paradigm simulations were simulated to test the FPGA system real-time behavior using the rat computational model. The closed-loop system monitors breathing and changes in respiratory demands to drive diaphragmatic stimulation. The simulated results inform future acute animal experiments and constitute the first step toward the development of a neuromorphic, adaptive, compact, low-power, implantable device. The bio-inspired hardware design optimizes the FPGA resource and time costs while harnessing the computational power of spike-based neuromorphic hardware. Its real-time feature makes it suitable for in vivo applications. PMID:27378844

  12. Three-dimensionally printed biological machines powered by skeletal muscle.

    PubMed

    Cvetkovic, Caroline; Raman, Ritu; Chan, Vincent; Williams, Brian J; Tolish, Madeline; Bajaj, Piyush; Sakar, Mahmut Selman; Asada, H Harry; Saif, M Taher A; Bashir, Rashid

    2014-07-15

    Combining biological components, such as cells and tissues, with soft robotics can enable the fabrication of biological machines with the ability to sense, process signals, and produce force. An intuitive demonstration of a biological machine is one that can produce motion in response to controllable external signaling. Whereas cardiac cell-driven biological actuators have been demonstrated, the requirements of these machines to respond to stimuli and exhibit controlled movement merit the use of skeletal muscle, the primary generator of actuation in animals, as a contractile power source. Here, we report the development of 3D printed hydrogel "bio-bots" with an asymmetric physical design and powered by the actuation of an engineered mammalian skeletal muscle strip to result in net locomotion of the bio-bot. Geometric design and material properties of the hydrogel bio-bots were optimized using stereolithographic 3D printing, and the effect of collagen I and fibrin extracellular matrix proteins and insulin-like growth factor 1 on the force production of engineered skeletal muscle was characterized. Electrical stimulation triggered contraction of cells in the muscle strip and net locomotion of the bio-bot with a maximum velocity of ∼ 156 μm s(-1), which is over 1.5 body lengths per min. Modeling and simulation were used to understand both the effect of different design parameters on the bio-bot and the mechanism of motion. This demonstration advances the goal of realizing forward-engineered integrated cellular machines and systems, which can have a myriad array of applications in drug screening, programmable tissue engineering, drug delivery, and biomimetic machine design.

  13. Potential relationship between single nucleotide polymorphisms used in forensic genetics and diseases or other traits in European population.

    PubMed

    Pombar-Gomez, Maria; Lopez-Lopez, Elixabet; Martin-Guerrero, Idoia; Garcia-Orad Carles, Africa; de Pancorbo, Marian M

    2015-05-01

    Single nucleotide polymorphisms (SNPs) are an interesting option to facilitate the analysis of highly degraded DNA by allowing the reduction of the size of the DNA amplicons. The SNPforID 52-plex panel is a clear example of the use of non-coding SNPs in forensic genetics. However, nonstop advances in studies of genetic polymorphisms are leading to the discovery of new associations between SNPs and diseases. The aim of this study was to perform a comprehensive review of the state of association between the 52 SNPs in the 52-plex panel and diseases or other traits related to their treatment, such as drug response characters. In order to achieve this goal, we have conducted a bioinformatic search for each SNP included in the panel and the SNPs in linkage disequilibrium (LD) with them in the European population (r (2)  > 0.8). A total of 424 SNPs (52 in the panel and 372 in LD) were investigated in PubMed, Scopus, and dbSNP databases. Our results show that three SNPs in the SNPforID 52-plex panel (rs2107612, rs1979255, rs1463729) have been associated with diseases such as hypertension or macular degeneration, as well as drug response. Similarly, three out of the 372 SNPs in LD (rs2107614, r (2)  = 0.859; rs765250, r (2)  = 0.858; rs11064560, r (2)  = 0,887) are also associated with various pathologies. In view of these results, we propose the need for a periodic review of the SNPs used in forensic genetics in order to keep their associations with diseases or related phenotypes updated and to evaluate their continuity in forensic panels for avoiding legal and ethical conflicts.

  14. Establishment of a 10-Plex Quantitative Fluorescent-PCR Assay for Rapid Diagnosis of Sex Chromosome Aneuploidies

    PubMed Central

    Xie, Xingmei; Liang, Qiaoyi

    2014-01-01

    Sex chromosome aneuploidies occur commonly in the general population, with an incidence of 1 in 400 newborns. However, no tests specifically targeting sex chromosomes have been carried out in prenatal diagnosis or newborn screening, resulting in late recognition of these diseases. In this study, a rapid diagnostic method for sex chromosome aneuploidies was established using Quantitative Fluorescent-PCR (QF-PCR). Ten markers were included in one multiplex QF-PCR assay, including two sex determination genes (AMXY and SRY), five X-linked short tandem repeats (STRs; DXS1053, DXS981, DXS6809, DXS1187, and DXS8377), one X/Y-common STR (X22), and two autosomal STRs (D13S305 and D21S11). Retrospective tests of 70 cases with known cytogenetic results indicated that the 10-plex QF-PCR assay could well determine sex chromosome copy numbers by both allelic peak numbers and a sex chromosome dosage calculation with the autosomal STRs as internal controls. Prospective comparison with cytogenetic karyotyping on 534 cases confirmed that the 10-plex QF-PCR assay could be well employed for sex chromosome aneuploidy diagnosis in at least the Chinese Han population. This is the first QF-PCR test for the diagnosis of sex chromosome aneuploidies in the Chinese population. This test is superior to previous designs by including up to 8 sex-linked markers covering different parts of sex chromosomes as well as employing internal controls for copy number dosage calculation in a single PCR reaction. Due to simple technique and data analysis, as well as easy implementation within routine clinical services, this method is of great clinical application value and could be widely applied. PMID:25207978

  15. Development of a new 26plex Y-STRs typing system for forensic application.

    PubMed

    Zhang, Suhua; Tian, Huaizhou; Wang, Zheng; Zhao, Shumin; Hu, Zhen; Li, Chengtao; Ji, Chaoneng

    2014-11-01

    In this study, 26plex Y-STRs typing system, including 17 Y-STRs (DYS19, DYS389I, DYS389II, DYS390, DYS391, DYS392, DYS393, DYS385ab, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS635 and GATA H4) recommended as YHRD standard loci and nine new highly discriminating Y-STRs (DYS549, DYS643, DYS388, DYS570, DYS533, DYS576, DYS460, DYS481 and DYS449), was established with 5-dye fluorescences labelling. Developmental validation indicated that the 26plex Y-STRs typing system was reproducible, accurate, sensitive and robust. The sensitivity of the system was such that a full profile was obtainable even with 125pg of male DNA. Specificity testing was demonstrated by the lack of cross-reactivity with a variety of commonly encountered animal species and bacteria. Also, the multiplex is suitable for mixture study. An average of above 97% of the minor alleles detected with the male/male mixture with 1:3 and 3:1 ratios, while an average of above 70% of the minor alleles detected with the male/male mixture with 1:19 and 19:1 ratios. Full profiles are consistently detected with 125pg of male DNA, even in the presence of excessive amounts of female DNA. In addition, the whole PCR amplification of the 26 Y-STRs can finish in 1h, making the multiplex system suitable for fast-detection. For the forensic evaluation of the multiplex system, 516 haplotypes were found among 517 unrelated males. HD of the multiplex system was 0.9999925 while DC was 0.9980658, which is suitable for forensic application. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Duchenne/Becker muscular dystrophy: A report on clinical, biochemical, and genetic study in Gujarat population, India

    PubMed Central

    Rao, Mandava V.; Sindhav, Gaurang M.; Mehta, Jitendra J.

    2014-01-01

    Objective: In India, various groups have studied different regions to find out deletion pattern of dystrophin gene. We have investigated its deletion pattern among Duchenne/Becker muscular dystrophy (D/BMD) patients across Gujarat. Moreover, in this study we also correlate the same with reading frame rule. However, we too consider various clinicopathological features to establish as adjunct indices when deletion detection fails. Materials and Methods: In this pilot study, a total of 88 D/BMD patients consulting at our centers in Gujarat, India were included. All patients were reviewed on basis of their clinical characteristics, tested by three primer sets of 10-plex, 9-plex, and 7-plex polymerase chain reaction (PCR) for genetic analysis; whereas, biochemical indices were measured using automated biochemical analyzers. Results: The diagnosis of D/BMD was confirmed by multiplex-PCR (M-PCR) in D/BMD patients. A number of 65 (73.86%) out of 88 patients showed deletion in dystrophin gene. The exon 50 (58.46%) was the most frequent deletion found in our study. The mean age of onset of DMD and BMD was 4.09 ± 0.15 and 7.14 ± 0.55 years, respectively. In patients, mean creatine phosphokinase (CPK), lactate dehydrogenase (LDH), and myoglobin levels were elevated significantly (P < 0.05) in comparison to controls. Addition to CPK, LDH and myoglobin are good adjunct when deletion detection failed. These data are further in accordance with world literature when correlated with frame rule. Conclusion: The analysis has been carried out for the first time for a total of 88 D/BMD patients particularly from Gujarat, India. More research is essential to elucidate specific mutation pattern in association with management and therapies of proband. PMID:25221400

  17. Duchenne/Becker muscular dystrophy: A report on clinical, biochemical, and genetic study in Gujarat population, India.

    PubMed

    Rao, Mandava V; Sindhav, Gaurang M; Mehta, Jitendra J

    2014-07-01

    In India, various groups have studied different regions to find out deletion pattern of dystrophin gene. We have investigated its deletion pattern among Duchenne/Becker muscular dystrophy (D/BMD) patients across Gujarat. Moreover, in this study we also correlate the same with reading frame rule. However, we too consider various clinicopathological features to establish as adjunct indices when deletion detection fails. In this pilot study, a total of 88 D/BMD patients consulting at our centers in Gujarat, India were included. All patients were reviewed on basis of their clinical characteristics, tested by three primer sets of 10-plex, 9-plex, and 7-plex polymerase chain reaction (PCR) for genetic analysis; whereas, biochemical indices were measured using automated biochemical analyzers. The diagnosis of D/BMD was confirmed by multiplex-PCR (M-PCR) in D/BMD patients. A number of 65 (73.86%) out of 88 patients showed deletion in dystrophin gene. The exon 50 (58.46%) was the most frequent deletion found in our study. The mean age of onset of DMD and BMD was 4.09 ± 0.15 and 7.14 ± 0.55 years, respectively. In patients, mean creatine phosphokinase (CPK), lactate dehydrogenase (LDH), and myoglobin levels were elevated significantly (P < 0.05) in comparison to controls. Addition to CPK, LDH and myoglobin are good adjunct when deletion detection failed. These data are further in accordance with world literature when correlated with frame rule. The analysis has been carried out for the first time for a total of 88 D/BMD patients particularly from Gujarat, India. More research is essential to elucidate specific mutation pattern in association with management and therapies of proband.

  18. A dynamic bead-based microarray for parallel DNA detection

    NASA Astrophysics Data System (ADS)

    Sochol, R. D.; Casavant, B. P.; Dueck, M. E.; Lee, L. P.; Lin, L.

    2011-05-01

    A microfluidic system has been designed and constructed by means of micromachining processes to integrate both microfluidic mixing of mobile microbeads and hydrodynamic microbead arraying capabilities on a single chip to simultaneously detect multiple bio-molecules. The prototype system has four parallel reaction chambers, which include microchannels of 18 × 50 µm2 cross-sectional area and a microfluidic mixing section of 22 cm length. Parallel detection of multiple DNA oligonucleotide sequences was achieved via molecular beacon probes immobilized on polystyrene microbeads of 16 µm diameter. Experimental results show quantitative detection of three distinct DNA oligonucleotide sequences from the Hepatitis C viral (HCV) genome with single base-pair mismatch specificity. Our dynamic bead-based microarray offers an effective microfluidic platform to increase parallelization of reactions and improve microbead handling for various biological applications, including bio-molecule detection, medical diagnostics and drug screening.

  19. The interaction between anti-Ro/SSA and anti-La/SSB autoantibodies and anti-infectious antibodies in a wide spectrum of auto-immune diseases: another angle of the autoimmune mosaic.

    PubMed

    Agmon-Levin, Nancy; Dagan, Amir; Peri, Yogev; Anaya, Juan-Manuel; Selmi, Carlo; Tincani, Angela; Bizzaro, Nicola; Stojanovich, Ljudmila; Damoiseaux, Jan; Cohen Tervaert, Jan Willem; Mosca, Marta; Cervera, Ricard; Shoenfeld, Yehuda

    2017-01-01

    The presence of anti-Ro/SSA and anti-La/SSB antibodies has been linked with autoimmunity in general and with several autoimmune diseases (AID) in particular. In the current study we evaluated these antibodies in a wide spectrum of AID as well as the links between them and anti-infectious antibodies. We examined 2082 sera from patients with 16 different AID compared to 524 sera from geographically-matched healthy controls, for the presence and titres of anti-Ro/SSA and anti-La/SSB. All samples were also tested for a variety of anti-infectious agents' antibodies using the BioPlex 2200-immunoassay (Bio-Rad, USA). Anti-Ro/SSA was more prevalent, with significantly higher titre in 5 autoimmune diseases namely Sjögren's syndrome (SS), systemic lupus erythematosus (SLE), antiphospholipid syndrome (APS) both primary and APS linked to SLE, systemic sclerosis (SSc) and primary biliary cirrhosis (PBC). Anti-La/SSB was more prevalent with higher titers in SS, SLE, APS linked to SLE and PBC. Prevalence, but not titers, of both antibodies were higher also in polymyositis (PM). Additionally, we found a correlation between anti-Ro/SSA antibodies and antibodies of the IgM and IgG subtypes directed at cytomegalovirus as well as IgG-antibodies directed at Epstein-Barr virus (EBV) and toxoplasma (p<0.001). Anti-La/SSB antibodies correlated with the presence of IgG antibodies against EBV early antigen (p<0.001). In a large cohort of patients with autoimmune diseases we found an association between anti-Ro/SSA and anti-La/SSB antibodies and 6 autoimmune diseases, amongst which primary APS and PM. Additionally, we observed linkages between these autoantibodies and anti-infectious antibodies directed at Epstein-Barr virus, toxoplasma and cytomegalovirus. Our findings support the concept of interplay between infectious agents and autoimmunity, such as the plausibility of an infectious agent that trigger the immune system to produce specific antibodies which will later result in a unique group of AID.

  20. Mass Spectrometry and Multiplex Antigen Assays to Assess Microbial Quality and Toxin Production of Staphylococcus aureus Strains Isolated from Clinical and Food Samples

    PubMed Central

    Attien, Paul; Sina, Haziz; Moussaoui, Wardi; Zimmermann-Meisse, Gaëlle; Dadié, Thomas; Keller, Daniel; Riegel, Philippe; Edoh, Vincent; Kotchoni, Simeon O.; Djè, Marcellin; Prévost, Gilles

    2014-01-01

    The aim of our study was to investigate the microbial quality of meat products and on some clinical samples in Abidjan focused on Staphylococcus genus and the toxin production profile of Staphylococcus aureus (S. aureus) isolated. Bacteria were collected from 240 samples of three meat products sold in Abidjan and 180 samples issued from clinical infections. The strains were identified by both microbiological and MALDI-TOF-MS methods. The susceptibility to antibiotics was determined by the disc diffusion method. The production of Panton-Valentine Leukocidin, LukE/D, and epidermolysins was screened using radial gel immunodiffusion. The production of staphylococcal enterotoxins and TSST-1 was screened by a Bio-Plex Assay. We observed that 96/240 of meat samples and 32/180 of clinical samples were contaminated by Staphylococcus. Eleven species were isolated from meats and 4 from clinical samples. Forty-two S. aureus strains were isolated from ours samples. Variability of resistance was observed for most of the tested antibiotics but none of the strains displays a resistance to imipenem and quinolones. We observed that 89% of clinical S. aureus were resistant to methicillin against 58% for those issued from meat products. All S. aureus isolates issued from meat products produce epidermolysins whereas none of the clinical strains produced these toxins. The enterotoxins were variably produced by both clinical and meat product samples. PMID:24987686

  1. Broncho-Vaxom attenuates allergic airway inflammation by restoring GSK3β-related T regulatory cell insufficiency.

    PubMed

    Fu, Ran; Li, Jian; Zhong, Hua; Yu, Dehong; Zeng, Xianping; Deng, Mengxia; Sun, Yueqi; Wen, Weiping; Li, Huabin

    2014-01-01

    Oral administration of bacterial extracts (eg, Broncho-Vaxom (BV)) has been proposed to attenuate asthma through modulating Treg cells. However, the underlying mechanism has not been fully characterized. This study sought to assess the effects of oral administration of BV on GSK-3β expression and Treg cells in ovalbumin (OVA)-induced asthmatic mice models. Asthmatic mice models were established with OVA challenge and treated with oral administration of BV. Next, infiltration of inflammatory cells including eosinophil and neutrophils, mucous metaplasia, levels of Th1/Th2/Treg-typed cytokines and expression of GSK3β and Foxp3 were examined in asthmatic mice models by histological analysis, Bio-Plex and western blot, respectively. Moreover, the frequencies of Treg cells were evaluated in cultured splenocytes by flow cytometry in the presence of BV or GSK3β siRNA interference. We found significant decrease of infiltrated inflammatory cells in bronchoalveolar lavage fluid (BALF) in asthmatic mice models after oral administration of BV. Oral administration of BV was shown to significantly suppress mucus metaplasia, Th2-typed cytokine levels and GSK3β expression while increasing Foxp3 production in asthmatic mice models. Moreover, BV significantly enhanced GSK3β-related expansion of Treg cells in cultured spleen cells in vitro. Our findings provide evidence that oral administration of BV is capable of attenuating airway inflammation in asthmatic mice models, which may be associated with GSK3β-related expansion of Treg cells.

  2. Bioregenerative life support: not a picnic

    NASA Technical Reports Server (NTRS)

    Knott, W. M.

    1998-01-01

    If humans are to live permanently in space, regenerative life support systems are an enabling technology and must replace the picnic approach of taking all supplies required for each mission. These systems are classified by technologies as either physical/chemical or bioregenerative. Both of these system-types can recycle water, remove carbon dioxide, produce oxygen, and recover essential elements from waste products. Bioregenerative can also produce food, thus, making it essential if humans are to exist in space independent of earth. A solely bioregenerative life support system includes plants as a biomass production module and microbial organisms in bioreactors as a resource recovery module. In the Advanced Life Support Program, bioregenerative life support systems are being investigated through a research and technology development project which includes large scale testing as part of the Breadboard Project and human tests conducted in the soon to be constructed BioPlex facility. Research and technology development efforts are directed toward optimizing biomass productivity in controlled chambers by developing light weight, energy efficient, and automated systems; recycling liquid and solid wastes; baselining the operation of bioreactors; determining system microbial stability; assessing chemical contamination; and building models required for long term system operations. The program will include space flight studies in the near future to determine if these life support technologies will function in microgravity. When a bioregenerative system is finally incorporated into a mission, the conversion from a picnic and resupply mentality to permanent recycling and independence from earth will be complete.

  3. Vaginal cytokines do not correlate with postmenopausal vulvovaginal symptoms.

    PubMed

    Kollmann, Zahraa; Bersinger, Nick; von Wolff, Michael; Thurman, Andrea R; Archer, David F; Stute, Petra

    2015-04-01

    Exploratory pilot study to determine the correlation between postmenopausal vulvovaginal symptoms and vaginal cytokine levels. Postmenopausal women (n = 34) not using menopausal hormone therapy and presenting with or without symptoms of vulvovaginal irritation were screened. Each participant underwent a vaginal examination and screening for vaginitis. A cervicovaginal lavage (CVL) with sterile saline and a peripheral blood sample were obtained. Main outcome measures were assessed by Luminex® X-map method on the Bio-Plex® platform. Main outcome measures were cervicovaginal and serum interleukin (IL)-4, IL-5, IL-10, IL-12, IL-13, TNF-α, GM-CSF, MIP-1-alpha and RANTES level. Cervicovaginal cytokines were adjusted to total protein concentration [pg/mcg protein]. Twenty-six postmenopausal women were enrolled (symptomatic: n = 15; asymptomatic: n = 11). There were no significant differences between groups: age, age at menopause, vaginal pH and all CVL and serum cytokines (IL-4, IL-5, IL-10, IL-12, IL-13, TNF-α, GM-CSF, MIP-1-alpha and RANTES). GM-CSF was the most abundant vaginal cytokine (symptomatic: 146.5 ± 165.6 pg/mcg protein; asymptomatic: 146.0 ± 173.5 pg/mcg protein; p = 0.99). Postmenopausal vulvovaginal symptoms did not correlate with vaginal inflammatory marker. There was no difference in serum or CVL cytokines between symptomatic and asymptomatic postmenopasual women. Vaginal symptoms after menopause are not related to the vaginal cytokine changes associated with loss of estrogen.

  4. A bio-inspired structural health monitoring system based on ambient vibration

    NASA Astrophysics Data System (ADS)

    Lin, Tzu-Kang; Kiremidjian, Anne; Lei, Chi-Yang

    2010-11-01

    A structural health monitoring (SHM) system based on naïve Bayesian (NB) damage classification and DNA-like expression data was developed in this research. Adapted from the deoxyribonucleic acid (DNA) array concept in molecular biology, the proposed structural health monitoring system is constructed utilizing a double-tier regression process to extract the expression array from the structural time history recorded during external excitations. The extracted array is symbolized as the various genes of the structure from the viewpoint of molecular biology and reflects the possible damage conditions prevalent in the structure. A scaled down, six-story steel building mounted on the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark. The structural response at different damage levels and locations under ambient vibration was collected to support the database for the proposed SHM system. To improve the precision of detection in practical applications, the system was enhanced by an optimization process using the likelihood selection method. The obtained array representing the DNA array of the health condition of the structure was first evaluated and ranked. A total of 12 groups of expression arrays were regenerated from a combination of four damage conditions. To keep the length of the array unchanged, the best 16 coefficients from every expression array were selected to form the optimized SHM system. Test results from the ambient vibrations showed that the detection accuracy of the structural damage could be greatly enhanced by the optimized expression array, when compared to the original system. Practical verification also demonstrated that a rapid and reliable result could be given by the final system within 1 min. The proposed system implements the idea of transplanting the DNA array concept from molecular biology into the field of SHM.

  5. Dissolvable Films of Silk Fibroin for Ultrathin Conformal Bio-integrated Electronics

    DTIC Science & Technology

    2010-01-01

    spin- cast films of polyimide (PI) served as a support for arrays of electrodes designed for passive neural recording. Control devices consisted of...optically transparent, mechanically robust, biocompatible silk fibroin films. Adv. Mater. 20, 3070–3072 (2008). 20. Murphy, A. R., John, P. S. & Kaplan, D...induced colour change on periodically nanopatterned silk films. Opt. Express 17, 21271–21279 (2009). 25. Parker, S. T. et al. Biocompatible silk printed

  6. Dissolvable Films of Silk Fibroin for Ultrathin Conformal Bio-Integrated Electronics

    DTIC Science & Technology

    2010-06-01

    the systems described in the following, ultrathin, spin- cast films of polyimide (PI) served as a support for arrays of electrodes designed for...micropatterning of optically transparent, mechanically robust, biocompatible silk fibroin films. Adv. Mater. 20, 3070–3072 (2008). 20. Murphy, A. R., John, P. S...analysis of induced colour change on periodically nanopatterned silk films. Opt. Express 17, 21271–21279 (2009). 25. Parker, S. T. et al. Biocompatible

  7. Printable Silicon Nanomembranes for Solar-Powered, Bi-Directional Phased-Array-Antenna Communication System on Flexible Substrates

    DTIC Science & Technology

    2013-04-01

    Identification (RFID), Large Area Flexible Displays, Electronic Paper, Bio - Sensors , Large Area Conformal and Flexible Antennas, Smart and Interactive Textiles...Lepeshkin, R. W. Boyd, C. Chase, and J. E. Fajardo, “An environmental sensor based on an integrated optical whispering gallery mode disk resonator ...Ubiquitous Sensor Networks (USN), Vehicle Clickers Readers, Real Time Locating Systems, Lighting, Photovoltaics etc. FA9550-11-C-0014 STTR Phase II

  8. ARSENIC CONTAMINATION AT THE INDUSTRI-PLEX SUPERFUND SITE, WOBURN, MA

    EPA Science Inventory

    Arsenate coprecipitated with hydrous ferric oxide (HFO) was stabilized against dissolution during transformation of HFO to more crystalline iron (hydr)oxides. The rate of arsenate stabilization approximately coincided with the rate of HFO transformation at pH 6 and 40 ?C. Compa...

  9. CASE STUDY: SITE CONCEPTUAL MODEL FOR ENHANCED MNA OF ARSENIC

    EPA Science Inventory

    Field investigations have been conducted to understand the fate of arsenic in contaminated ground water during discharge into the Halls Brook Holding Area (HBHA) Pond at the Industri-Plex Superfund Site in Massachusetts. The ground water plume contains elevated levels of arsenic...

  10. Results for five sets of forensic genetic markers studied in a Greek population sample.

    PubMed

    Tomas, C; Skitsa, I; Steinmeier, E; Poulsen, L; Ampati, A; Børsting, C; Morling, N

    2015-05-01

    A population sample of 223 Greek individuals was typed for five sets of forensic genetic markers with the kits NGM SElect™, SNPforID 49plex, DIPplex®, Argus X-12 and PowerPlex® Y23. No significant deviation from Hardy-Weinberg expectations was observed for any of the studied markers after Holm-Šidák correction. Statistically significant (P<0.05) levels of linkage disequilibrium were observed between markers within two of the studied X-chromosome linkage groups. AMOVA analyses of the five sets of markers did not show population structure when the individuals were grouped according to their geographic origin. The Greek population grouped closely to the other European populations measured by F(ST)(*) distances. The match probability ranged from a value of 1 in 2×10(7) males by using haplotype frequencies of four X-chromosome haplogroups in males to 1 in 1.73×10(21) individuals for 16 autosomal STRs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Quaternary ammonium isobaric tag for a relative and absolute quantification of peptides.

    PubMed

    Setner, Bartosz; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2018-02-01

    Isobaric labeling quantification of peptides has become a method of choice for mass spectrometry-based proteomics studies. However, despite of wide variety of commercially available isobaric tags, none of the currently available methods offers significant improvement of sensitivity of detection during MS experiment. Recently, many strategies were applied to increase the ionization efficiency of peptides involving chemical modifications introducing quaternary ammonium fixed charge. Here, we present a novel quaternary ammonium-based isobaric tag for relative and absolute quantification of peptides (QAS-iTRAQ 2-plex). Upon collisional activation, the new stable benzylic-type cationic reporter ion is liberated from the tag. Deuterium atoms were used to offset the differential masses of a reporter group. We tested the applicability of QAS-iTRAQ 2-plex reagent on a series of model peptides as well as bovine serum albumin tryptic digest. Obtained results suggest usefulness of this isobaric ionization tag for relative and absolute quantification of peptides. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Hydrophilic/hydrophobic surface modification impact on colloid lithography: Schottky-like defects, dislocation, and ideal distribution

    NASA Astrophysics Data System (ADS)

    Burtsev, Vasilii; Marchuk, Valentina; Kugaevskiy, Artem; Guselnikova, Olga; Elashnikov, Roman; Miliutina, Elena; Postnikov, Pavel; Svorcik, Vaclav; Lyutakov, Oleksiy

    2018-03-01

    Nano-spheres lithography is actually considered as a powerful tool to manufacture various periodic structures with a wide potential in the field of nano- and micro-fabrication. However, during self-assembling of colloid microspheres, various defects and mismatches can appear. In this work the size and quality of single-domains of closed-packed polystyrene (PS), grown up on thin Au layers modified by hydrophilic or hydrophobic functional groups via diazonium chemistry was studied. The effects of the surface modification on the quality and single-domain size of polystyrene (PS) microspheres array were investigated and discussed. Modified surfaces were characterized using the AFM and wettability tests. PS colloidal suspension was deposited using the drop evaporation method. Resulted PS microspheres array was characterized using the SEM, AFM and confocal microscopy technique.

  13. Continuous fabrication of nanostructure arrays for flexible surface enhanced Raman scattering substrate

    PubMed Central

    Zhang, Chengpeng; Yi, Peiyun; Peng, Linfa; Lai, Xinmin; Chen, Jie; Huang, Meizhen; Ni, Jun

    2017-01-01

    Surface-enhanced Raman spectroscopy (SERS) has been a powerful tool for applications including single molecule detection, analytical chemistry, electrochemistry, medical diagnostics and bio-sensing. Especially, flexible SERS substrates are highly desirable for daily-life applications, such as real-time and in situ Raman detection of chemical and biological targets, which can be used onto irregular surfaces. However, it is still a major challenge to fabricate the flexible SERS substrate on large-area substrates using a facile and cost-effective technique. The roll-to-roll ultraviolet nanoimprint lithography (R2R UV-NIL) technique provides a solution for the continuous fabrication of flexible SERS substrate due to its high-speed, large-area, high-resolution and high-throughput. In this paper, we presented a facile and cost-effective method to fabricate flexible SERS substrate including the fabrication of polymer nanostructure arrays and the metallization of the polymer nanostructure arrays. The polymer nanostructure arrays were obtained by using R2R UV-NIL technique and anodic aluminum oxide (AAO) mold. The functional SERS substrates were then obtained with Au sputtering on the surface of the polymer nanostructure arrays. The obtained SERS substrates exhibit excellent SERS and flexibility performance. This research can provide a beneficial direction for the continuous production of the flexible SERS substrates. PMID:28051175

  14. Surface wave energy absorption by a partially submerged bio-inspired canopy.

    PubMed

    Nové-Josserand, C; Castro Hebrero, F; Petit, L-M; Megill, W M; Godoy-Diana, R; Thiria, B

    2018-03-27

    Aquatic plants are known to protect coastlines and riverbeds from erosion by damping waves and fluid flow. These flexible structures absorb the fluid-borne energy of an incoming fluid by deforming mechanically. In this paper we focus on the mechanisms involved in these fluid-elasticity interactions, as an efficient energy harvesting system, using an experimental canopy model in a wave tank. We study an array of partially-submerged flexible structures that are subjected to the action of a surface wave field, investigating in particular the role of spacing between the elements of the array on the ability of our system to absorb energy from the flow. The energy absorption potential of the canopy model is examined using global wave height measurements for the wave field and local measurements of the elastic energy based on the kinematics of each element of the canopy. We study different canopy arrays and show in particular that flexibility improves wave damping by around 40%, for which half is potentially harvestable.

  15. Droplet Array-Based 3D Coculture System for High-Throughput Tumor Angiogenesis Assay.

    PubMed

    Du, Xiaohui; Li, Wanming; Du, Guansheng; Cho, Hansang; Yu, Min; Fang, Qun; Lee, Luke P; Fang, Jin

    2018-03-06

    Angiogenesis is critical for tumor progression and metastasis, and it progresses through orchestral multicellular interactions. Thus, there is urgent demand for high-throughput tumor angiogenesis assays for concurrent examination of multiple factors. For investigating tumor angiogenesis, we developed a microfluidic droplet array-based cell-coculture system comprising a two-layer polydimethylsiloxane chip featuring 6 × 9 paired-well arrays and an automated droplet-manipulation device. In each droplet-pair unit, tumor cells were cultured in 3D in one droplet by mixing cell suspensions with Matrigel, and in the other droplet, human umbilical vein endothelial cells (HUVECs) were cultured in 2D. Droplets were fused by a newly developed fusion method, and tumor angiogenesis was assayed by coculturing tumor cells and HUVECs in the fused droplet units. The 3D-cultured tumor cells formed aggregates harboring a hypoxic center-as observed in vivo-and secreted more vascular endothelial growth factor (VEGF) and more strongly induced HUVEC tubule formation than did 2D-cultured tumor cells. Our single array supported 54 assays in parallel. The angiogenic potentials of distinct tumor cells and their differential responses to antiangiogenesis agent, Fingolimod, could be investigated without mutual interference in a single array. Our droplet-based assay is convenient to evaluate multicellular interaction in high throughput in the context of tumor sprouting angiogenesis, and we envision that the assay can be extensively implementable for studying other cell-cell interactions.

  16. Dielectrophoresis-Assisted Integration of 1024 Carbon Nanotube Sensors into a CMOS Microsystem.

    PubMed

    Seichepine, Florent; Rothe, Jörg; Dudina, Alexandra; Hierlemann, Andreas; Frey, Urs

    2017-05-01

    Carbon-nanotube (CNT)-based sensors offer the potential to detect single-molecule events and picomolar analyte concentrations. An important step toward applications of such nanosensors is their integration in large arrays. The availability of large arrays would enable multiplexed and parallel sensing, and the simultaneously obtained sensor signals would facilitate statistical analysis. A reliable method to fabricate an array of 1024 CNT-based sensors on a fully processed complementary-metal-oxide-semiconductor microsystem is presented. A high-yield process for the deposition of CNTs from a suspension by means of liquid-coupled floating-electrode dielectrophoresis (DEP), which yielded 80% of the sensor devices featuring between one and five CNTs, is developed. The mechanism of floating-electrode DEP on full arrays and individual devices to understand its self-limiting behavior is studied. The resistance distributions across the array of CNT devices with respect to different DEP parameters are characterized. The CNT devices are then operated as liquid-gated CNT field-effect-transistors (LG-CNTFET) in liquid environment. Current dependency to the gate voltage of up to two orders of magnitude is recorded. Finally, the sensors are validated by studying the pH dependency of the LG-CNTFET conductance and it is demonstrated that 73% of the CNT sensors of a given microsystem show a resistance decrease upon increasing the pH value. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Anaerobic Nitrate-Dependent Metal Bio-Oxidation

    NASA Astrophysics Data System (ADS)

    Weber, K.; Knox, T.; Achenbach, L. A.; Coates, J. D.

    2007-12-01

    Direct biological oxidation of reduced metals (Fe(II) and U(IV)) coupled to nitrate reduction at circumneutral pH under anaerobic conditions has been recognized in several environments as well as pure culture. Several phylogentically diverse mesophilic bacteria have been described as capable of anaerobic, nitrate-dependent Fe(II) oxidation (NFOx). Our recent identification of a freshwater mesophilic, lithoautotroph, Ferrutens nitratireducens strain 2002, capable of growth through NFOx presents an opportunity to further study metal bio- oxidation. Continuing physiological studies revealed that in addition to Fe(II) oxidation, strain 2002 is capable of oxidizing U(IV) (4 μM) in washed cell suspensions with nitrate serving as the electron acceptor. Pasteurized cultures exhibited abiotic oxidation of 2 μM U(IV). Under growth conditions, strain 2002 catalyzed the oxidation of 12 μM U(IV) within a two week period. Cultures amended with sodium azide, an electron transport inhibitor, demonstrated limited oxidation (7 μM) similar to pasteurized cultures, supporting the direct role of electron transport in U(IV) bio-oxidation. The oxidation of U(IV) coupled denitrification at circumneutral pH would yield enough energy to support anaerobic microbial growth (ΔG°'= -460.36 kJ/mole). It is currently unknown whether or not strain 2002 can couple this metabolism to growth. The growth of F. nitratireducens strain 2002 utilizing Fe(II) as the sole electron donor was previously demonstrated. The amount of U(IV) (~12 μM) that strain 2002 oxidized under similar autotrophic growth conditions yields 0.0019 kJ, enough energy for the generation of ATP (5.3 x 10-20 kJ ATP-1), but not enough energy for cell replication as calculated for nitrate-dependent Fe(II) oxidizing conditions (0.096 kJ) assuming a similar metabolism. In addition to F. nitratireducens strain 2002, a nitrate-dependent Fe(II) oxidizing bacterium isolated from U contaminated groundwater, Diaphorobacter sp. strain TPSY, was also capable of nitrate- dependent U(IV) oxidation (8 μM over 24 hours, pseudo first order rate constant of 0.12 ± 0.02 hr-1) in washed cell suspensions. Further biochemical investigation of nitrate-dependent U(IV) oxidation in strain TPSY revealed the expression of several putative high molecular weight proteins specific to this metabolism. Together with the previously described metabolic ability of Geobacter metallireducens (Finneran et al. 2002) and Thiobacillus denitrificans (Beller 2005), these data indicate that anaerobic, metal oxidation may be a ubiquitous microbial metabolism.

  18. High sample throughput genotyping for estimating C-lineage introgression in the dark honeybee: an accurate and cost-effective SNP-based tool.

    PubMed

    Henriques, Dora; Browne, Keith A; Barnett, Mark W; Parejo, Melanie; Kryger, Per; Freeman, Tom C; Muñoz, Irene; Garnery, Lionel; Highet, Fiona; Jonhston, J Spencer; McCormack, Grace P; Pinto, M Alice

    2018-06-04

    The natural distribution of the honeybee (Apis mellifera L.) has been changed by humans in recent decades to such an extent that the formerly widest-spread European subspecies, Apis mellifera mellifera, is threatened by extinction through introgression from highly divergent commercial strains in large tracts of its range. Conservation efforts for A. m. mellifera are underway in multiple European countries requiring reliable and cost-efficient molecular tools to identify purebred colonies. Here, we developed four ancestry-informative SNP assays for high sample throughput genotyping using the iPLEX Mass Array system. Our customized assays were tested on DNA from individual and pooled, haploid and diploid honeybee samples extracted from different tissues using a diverse range of protocols. The assays had a high genotyping success rate and yielded accurate genotypes. Performance assessed against whole-genome data showed that individual assays behaved well, although the most accurate introgression estimates were obtained for the four assays combined (117 SNPs). The best compromise between accuracy and genotyping costs was achieved when combining two assays (62 SNPs). We provide a ready-to-use cost-effective tool for accurate molecular identification and estimation of introgression levels to more effectively monitor and manage A. m. mellifera conservatories.

  19. A Portrait of Ribosomal DNA Contacts with Hi-C Reveals 5S and 45S rDNA Anchoring Points in the Folded Human Genome

    PubMed Central

    Yu, Shoukai; Lemos, Bernardo

    2016-01-01

    Ribosomal RNAs (rRNAs) account for >60% of all RNAs in eukaryotic cells and are encoded in the ribosomal DNA (rDNA) arrays. The rRNAs are produced from two sets of loci: the 5S rDNA array resides exclusively on human chromosome 1, whereas the 45S rDNA array resides on the short arm of five human acrocentric chromosomes. The 45S rDNA gives origin to the nucleolus, the nuclear organelle that is the site of ribosome biogenesis. Intriguingly, 5S and 45S rDNA arrays exhibit correlated copy number variation in lymphoblastoid cells (LCLs). Here we examined the genomic architecture and repeat content of the 5S and 45S rDNA arrays in multiple human genome assemblies (including PacBio MHAP assembly) and ascertained contacts between the rDNA arrays and the rest of the genome using Hi-C datasets from two human cell lines (erythroleukemia K562 and lymphoblastoid cells). Our analyses revealed that 5S and 45S arrays each have thousands of contacts in the folded genome, with rDNA-associated regions and genes dispersed across all chromosomes. The rDNA contact map displayed conserved and disparate features between two cell lines, and pointed to specific chromosomes, genomic regions, and genes with evidence of spatial proximity to the rDNA arrays; the data also showed a lack of direct physical interaction between the 5S and 45S rDNA arrays. Finally, the analysis identified an intriguing organization in the 5S array with Alu and 5S elements adjacent to one another and organized in opposite orientation along the array. Portraits of genome folding centered on the ribosomal DNA array could help understand the emergence of concerted variation, the control of 5S and 45S expression, as well as provide insights into an organelle that contributes to the spatial localization of human chromosomes during interphase. PMID:27797956

  20. Ring-Interferometric Sol-Gel Bio-Sensor

    NASA Technical Reports Server (NTRS)

    Bearman, Gregory (Inventor); Cohen, David (Inventor)

    2006-01-01

    A biosensor embodying the invention includes a sensing volume having an array of pores sized for immobilizing a first biological entity tending to bind to a second biological entity in such a manner as to change an index of refraction of the sensing volume. The biosensor further includes a ring interferometer, one volumetric section of the ring interferometer being the sensing volume, a laser for supplying light to the ring interferometer, and a photodetector for receiving light from the interferometer.

  1. [Clinical validation of multiple biomarkers suspension array technology for ovarian cancer].

    PubMed

    Zhao, B B; Yang, Z J; Wang, Q; Pan, Z M; Zhang, W; Li, L

    2017-01-25

    Objective: To investigates the diagnostic value of combined detection serum CCL18, CXCL1 antigen, C1D, TM4SF1, FXR1, TIZ IgG autoantibody by suspension array for ovarian cancer. Methods: Suspension array was used to detect CCL18, CXCL1 antigen, C1D, TM4SF1, FXR1, TIZ IgG autoantibody in 120 cases of healthy women, 204 cases of patients with benign pelvic tumors, 119 cases of pelvic malignant tumor patients, and 40 cases with breast cancer, lung cancer oroliver cancer, respectively. Constructed diagnosis model of combined detection six biomarkers for diagnosis of ovarian malignant tumor. Constructed diagnosis model of combined detection autoantibodies to diagnose epithelial ovarian cancer. Analysed the value of detecting six biomarkers for diagnosis of ovarian malignant tumor and detecting autoantibodies for diagnosis of epithelial ovarian cancer. Analysed diagnostic value of detecting six biomarkers to diagnose stage Ⅰ and Ⅱepithelial ovarian cancer. Compared diagnostic value of detecting six biomarkers in diagnosis of tissue types and pathologic grading with that of CA(125). Results: Model of combined detecting six biomarkers to diagnose ovarian malignant tumor was logit ( P ) =-11.151+0.008×C1D+0.011×TM4SF1+0.011×TIZ-0.008×FXR1+0.021×CCL18+0.200×CXCL1. Model of combined detection autoantibodies to diagnose epithelial ovarian cancer was logit ( P ) =-5.137+0.013×C1D+0.014×TM4SF1+0.060×TIZ-0.060×FXR1. Sensitivity and specificity of detecting six biomarker to diagnose ovarian malignant tumor was 90.6% and 98.7%. Sensitivity and specificity of detecting autoantibodies to diagnose epithelial ovarian cancer was 75.8% and 96.7%. Combined detection for six biomarkers to diagnose serous and mucinous ovarian cancer was statistically no better than those of CA(125) ( P =0.196 and P =0.602, respectively); there was significantly difference in diagnosis of ovarian cancer ( P =0.023), and there was no significantly difference in diagnosis of different pathological grading ( P =0.089 and P =0.169, respectively). Conclusions: Constructing diagnosis model of combined detection six biomarker to diagnose ovarian malignant tumor and constructed diagnosis model of combined detectionautoantibodies to diagnose epithelial ovarian cancer. Combined detection six biomarkers to diagnose serous and mucinous ovarian tumors is better than that of CA(125).

  2. A simultaneous multichannel monophasic action potential electrode array for in vivo epicardial repolarization mapping.

    PubMed

    Sahakian, A V; Peterson, M S; Shkurovich, S; Hamer, M; Votapka, T; Ji, T; Swiryn, S

    2001-03-01

    While the recording of extracellular monophasic action potentials (MAPs) from single epicardial or endocardial sites has been performed for over a century, we are unaware of any previous successful attempt to record MAPs simultaneously from a large number of sites in vivo. We report here the design and validation of an array of MAP electrodes which records both depolarization and repolarization simultaneously at up to 16 epicardial sites in a square array on the heart in vivo. The array consists of 16 sintered Ag-AgCl electrodes mounted in a common housing with individual suspensions allowing each electrode to exert a controlled pressure on the epicardial surface. The electrodes are arranged in a square array, with each quadrant of four having an additional recessed sintered Ag-AgCl reference electrode at its center. A saline-soaked sponge establishes ionic contact between the reference electrodes and the tissue. The array was tested on six anesthetized open-chested pigs. Simultaneous diagnostic-quality MAP recordings were obtained from up to 13 out of 16 ventricular sites. Ventricular MAPs had amplitudes of 10-40 mV with uniform morphologies and stable baselines for up to 30 min. MAP duration at 90% repolarization was measured and shown to vary as expected with cycle length during sustained pacing. The relationship between MAP duration and effective refractory period was also confirmed. The ability of the array to detect local differences in repolarization was tested in two ways. Placement of the array straddling the atrioventricular (AV) junction yielded simultaneous atrial or ventricular recordings at corresponding sites during 1:1 and 2:1 AV conduction. Localized ischemia via constriction of a coronary artery branch resulted in shortening of the repolarization phase at the ischemic, but not the nonischemic, sites. In conclusion, these results indicate that the simultaneous multichannel MAP electrode array is a viable method for in vivo epicardial repolarization mapping. The array has the potential to be expanded to increase the number of sites and spatial resolution.

  3. THE ADIABATIC DEMAGNETIZATION REFRIGERATOR FOR THE MICRO-X SOUNDING ROCKET TELESCOPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wikus, P.; Bagdasarova, Y.; Figueroa-Feliciano, E.

    2010-04-09

    The Micro-X Imaging X-ray Spectrometer is a sounding rocket payload slated for launch in 2011. An array of Transition Edge Sensors, which is operated at a bath temperature of 50 mK, will be used to obtain a high resolution spectrum of the Puppis-A supernova remnant. An Adiabatic Demagnetization Refrigerator (ADR) with a 75 gram Ferric Ammonium Alum (FAA) salt pill in the bore of a 4 T superconducting magnet provides a stable heat sink for the detector array only a few seconds after burnout of the rocket motors. This requires a cold stage design with very short thermal time constants.more » A suspension made from Kevlar strings holds the 255 gram cold stage in place. It is capable of withstanding loads in excess of 200 g. Stable operation of the TES array in proximity to the ADR magnet is ensured by a three-stage magnetic shielding system which consists of a superconducting can, a high-permeability shield and a bucking coil. The development and testing of the Micro-X payload is well underway.« less

  4. Enhanced sub-micron colloidal particle separation with interdigitated microelectrode arrays using mixed AC/DC dielectrophoretic scheme.

    PubMed

    Swaminathan, Vikhram V; Shannon, Mark A; Bashir, Rashid

    2015-04-01

    Dielectrophoretic separation of particles finds a variety of applications in the capture of species such as cells, viruses, proteins, DNA from biological systems, as well as other organic and inorganic contaminants from water. The ability to capture particles is constrained by poor volumetric scaling of separation force with respect to particle diameter, as well as the weak penetration of electric fields in the media. In order to improve the separation of sub-micron colloids, we present a scheme based on multiple interdigitated electrode arrays under mixed AC/DC bias. The use of high frequency longitudinal AC bias breaks the shielding effects through electroosmotic micromixing to enhance electric fields through the electrolyte, while a transverse DC bias between the electrode arrays enables penetration of the separation force to capture particles from the bulk of the microchannel. We determine the favorable biasing conditions for field enhancement with the help of analytical models, and experimentally demonstrate the improved capture from sub-micron colloidal suspensions with the mixed AC/DC electrostatic excitation scheme over conventional AC-DEP methods.

  5. Laboratory Study on the Effect of Tidal Stream Turbines on Hydrodynamics and Sediment Dynamics

    NASA Astrophysics Data System (ADS)

    Amoudry, L.; Ramirez-Mendoza, R.; Peter, T.; McLelland, S.; Simmons, S.; Parsons, D. R.; Vybulkova, L.

    2016-02-01

    Tidal stream turbines (TST) are one potential technology for harnessing tidal energy, and the measurement and characterisation of their wakes is important both for environmental and development reasons. Indeed, wake recovery length is an important parameter for appropriate design of arrays, and wakes may result in altered dynamics both in the water column and at the seabed. We will report on laboratory scale experiments over a mobile sediment bed, which aim to quantify the detailed wake structure and its impact on sediment transport dynamics. A 0.2 m diameter model turbine was installed in a large-scale flume (16 m long, 1.6 m wide, 0.6 m deep) at the University of Hull's Total Environment Simulator and a steady current was driven over an artificial sediment bed using recirculating pumps. A high-resolution pulse-coherent acoustic Doppler profiler (Nortek Aquadopp HR) was used to measure vertical profiles of the three-dimensional mean current at different locations downstream of the model turbine. A three-dimensional Acoustic Ripple Profiler was used to map the bed and its evolution during the experiments. Acoustic backscatter systems were also deployed in two-dimensional arrays both along the flume and across the flume. These measurements revealed that the presence of the model turbine resulted in an expected reduction of the mean current and in changes in the vertical shear profiles. The bed mapping highlighted a horseshoe-shaped scour near the model turbine, and sediment deposition in the far wake region. The model turbine significantly influenced the suspension patterns, and generated significant asymmetry in the process, which was also evident from the other measurements (flow and sediment bed). These results highlight the effects induced by TSTs on near-bed hydrodynamics, suspension dynamics, and geomorphology, which may all have to be considered prior to large-scale deployments of arrays of TSTs in shelf seas.

  6. Label-free CMOS bio sensor with on-chip noise reduction scheme for real-time quantitative monitoring of biomolecules.

    PubMed

    Seong-Jin Kim; Euisik Yoon

    2012-06-01

    We present a label-free CMOS field-effect transistor sensing array to detect the surface potential change affected by the negative charge in DNA molecules for real-time monitoring and quantification. The proposed CMOS bio sensor includes a new sensing pixel architecture implemented with correlated double sampling for reducing offset fixed pattern noise and 1/f noise of the sensing devices. We incorporated non-surface binding detection which allows real-time continuous monitoring of DNA concentrations without immobilizing them on the sensing surface. Various concentrations of 19-bp oligonucleotides solution can be discriminated using the prototype device fabricated in 1- μm double-poly double-metal standard CMOS process. The detection limit was measured as 1.1 ng/μl with a dynamic range of 40 dB and the transient response time was measured less than 20 seconds.

  7. Bio-Inspired Asynchronous Pixel Event Tricolor Vision Sensor.

    PubMed

    Lenero-Bardallo, Juan Antonio; Bryn, D H; Hafliger, Philipp

    2014-06-01

    This article investigates the potential of the first ever prototype of a vision sensor that combines tricolor stacked photo diodes with the bio-inspired asynchronous pixel event communication protocol known as Address Event Representation (AER). The stacked photo diodes are implemented in a 22 × 22 pixel array in a standard STM 90 nm CMOS process. Dynamic range is larger than 60 dB and pixels fill factor is 28%. The pixels employ either simple pulse frequency modulation (PFM) or a Time-to-First-Spike (TFS) mode. A heuristic linear combination of the chip's inherent pseudo colors serves to approximate RGB color representation. Furthermore, the sensor outputs can be processed to represent the radiation in the near infrared (NIR) band without employing external filters, and to color-encode direction of motion due to an asymmetry in the update rates of the different diode layers.

  8. Particle dynamics and particle-cell interaction in microfluidic systems

    NASA Astrophysics Data System (ADS)

    Stamm, Matthew T.

    Particle-laden flow in a microchannel resulting in aggregation of microparticles was investigated to determine the dependence of the cluster growth rate on the following parameters: suspension void fraction, shear strain rate, and channel-height to particle-diameter ratio. The growth rate of an average cluster was found to increase linearly with suspension void fraction, and to obey a power-law relationships with shear strain rate as S 0.9 and channel-height to particle-diameter ratio as (h/d )--3.5. Ceramic liposomal nanoparticles and silica microparticles were functionalized with antibodies that act as targeting ligands. The bio-functionality and physical integrity of the cerasomes were characterized. Surface functionalization allows cerasomes to deliver drugs with selectivity and specificity that is not possible using standard liposomes. The functionalized particle-target cell binding process was characterized using BT-20 breast cancer cells. Two microfluidic systems were used; one with both species in suspension, the other with cells immobilized inside a microchannel and particle suspension as the mobile phase. Effects of incubation time, particle concentration, and shear strain rate on particle-cell binding were investigated. With both species in suspension, the particle-cell binding process was found to be reasonably well-described by a first-order model. Particle desorption and cellular loss of binding affinity in time were found to be negligible; cell-particle-cell interaction was identified as the limiting mechanism in particle-cell binding. Findings suggest that separation of a bound particle from a cell may be detrimental to cellular binding affinity. Cell-particle-cell interactions were prevented by immobilizing cells inside a microchannel. The initial stage of particle-cell binding was investigated and was again found to be reasonably well-described by a first-order model. For both systems, the time constant was found to be inversely proportional to particle concentration. The second system revealed the time constant to obey a power-law relationship with shear strain rate as tau∝ S-.37+/-.06. Under appropriate scaling, the behavior displayed in both systems is well-described by the same exponential curve. Identification of the appropriate scaling parameters allows for extrapolation and requires only two empirical values. This could provide a major head-start in any dosage optimization studies.

  9. Detection of the Odor Signature of Ovarian Cancer using DNA-Decorated Carbon Nanotube Field Effect Transistor Arrays

    NASA Astrophysics Data System (ADS)

    Kehayias, Christopher; Kybert, Nicholas; Yodh, Jeremy; Johnson, A. T. Charlie

    Carbon nanotubes are low-dimensional materials that exhibit remarkable chemical and bio-sensing properties and have excellent compatibility with electronic systems. Here, we present a study that uses an electronic olfaction system based on a large array of DNA-carbon nanotube field effect transistors vapor sensors to analyze the VOCs of blood plasma samples collected from patients with malignant ovarian cancer, patients with benign ovarian lesions, and age-matched healthy subjects. Initial investigations involved coating each CNT sensor with single-stranded DNA of a particular base sequence. 10 distinct DNA oligomers were used to functionalize the carbon nanotube field effect transistors, providing a 10-dimensional sensor array output response. Upon performing a statistical analysis of the 10-dimensional sensor array responses, we showed that blood samples from patients with malignant cancer can be reliably differentiated from those of healthy control subjects with a p-value of 3 x 10-5. The results provide preliminary evidence that the blood of ovarian cancer patients contains a discernable volatile chemical signature that can be detected using DNA-CNT nanoelectronic vapor sensors, a first step towards a minimally invasive electronic diagnostic technology for ovarian cancer.

  10. Novel method for high-throughput colony PCR screening in nanoliter-reactors

    PubMed Central

    Walser, Marcel; Pellaux, Rene; Meyer, Andreas; Bechtold, Matthias; Vanderschuren, Herve; Reinhardt, Richard; Magyar, Joseph; Panke, Sven; Held, Martin

    2009-01-01

    We introduce a technology for the rapid identification and sequencing of conserved DNA elements employing a novel suspension array based on nanoliter (nl)-reactors made from alginate. The reactors have a volume of 35 nl and serve as reaction compartments during monoseptic growth of microbial library clones, colony lysis, thermocycling and screening for sequence motifs via semi-quantitative fluorescence analyses. nl-Reactors were kept in suspension during all high-throughput steps which allowed performing the protocol in a highly space-effective fashion and at negligible expenses of consumables and reagents. As a first application, 11 high-quality microsatellites for polymorphism studies in cassava were isolated and sequenced out of a library of 20 000 clones in 2 days. The technology is widely scalable and we envision that throughputs for nl-reactor based screenings can be increased up to 100 000 and more samples per day thereby efficiently complementing protocols based on established deep-sequencing technologies. PMID:19282448

  11. Glyphing Decolonial Love through Urban Flash Mobbing and "Walking with Our Sisters"

    ERIC Educational Resources Information Center

    Recollet, Karyn

    2015-01-01

    This article contributes to understanding multi-plexed Indigenous resistance through examining spatial tags. As symbolic, moving critiques, spatial tagging intervenes normative structures of settler colonialism and provides the space through which radical decolonial love can emerge. This discussion of the production of spatial glyphs has…

  12. Structure and Properties of Intercalated Graphite Fiber-Polymer Composites.

    DTIC Science & Technology

    1983-07-07

    resistivities of all com- nal graphite. Experimental evidence (1,2) in- plexes were determined both before and after dicated that the electrophilic N02...others show promise as fluorinating agents in chemical synthesisI21. At this point, however, so little is Known of processing parameters and long-term

  13. Vacuum-assisted fluid flow in microchannels to pattern substrates and cells.

    PubMed

    Shrirao, Anil B; Kung, Frank H; Yip, Derek; Cho, Cheul H; Townes-Anderson, Ellen

    2014-09-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon et al 1999 Adv. Mater 11 946) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm(2). Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology.

  14. Vacuum-assisted Fluid Flow in Microchannels to Pattern Substrates and Cells

    PubMed Central

    Shrirao, Anil B.; Kung, Frank H.; Yip, Derek; Cho, Cheul H.; Townes-Anderson, Ellen

    2014-01-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-to-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon, Choi et al. 1999) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm2. Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology. PMID:24989641

  15. Design and fabrication of two-dimensional semiconducting bolometer arrays for HAWC and SHARC-II

    NASA Astrophysics Data System (ADS)

    Voellmer, George M.; Allen, Christine A.; Amato, Michael J.; Babu, Sachidananda R.; Bartels, Arlin E.; Benford, Dominic J.; Derro, Rebecca J.; Dowell, C. D.; Harper, D. A.; Jhabvala, Murzy D.; Moseley, S. H.; Rennick, Timothy; Shirron, Peter J.; Smith, W. W.; Staguhn, Johannes G.

    2003-02-01

    The High resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC II) will use almost identical versions of an ion-implanted silicon bolometer array developed at the National Aeronautics and Space Administration's Goddard Space Flight Center (GSFC). The GSFC "Pop-Up" Detectors (PUD's) use a unique folding technique to enable a 12 × 32-element close-packed array of bolometers with a filling factor greater than 95 percent. A kinematic Kevlar suspension system isolates the 200 mK bolometers from the helium bath temperature, and GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The JFET preamps operate at 120 K. Providing good thermal heat sinking for these, and keeping their conduction and radiation from reaching the nearby bolometers, is one of the principal design challenges encountered. Another interesting challenge is the preparation of the silicon bolometers. They are manufactured in 32-element, planar rows using Micro Electro Mechanical Systems (MEMS) semiconductor etching techniques, and then cut and folded onto a ceramic bar. Optical alignment using specialized jigs ensures their uniformity and correct placement. The rows are then stacked to create the 12 × 32-element array. Engineering results from the first light run of SHARC II at the Caltech Submillimeter Observatory (CSO) are presented.

  16. Green synthesis of gold nanoparticles using aqueous ethanol extract of Curcuma mangga rhizomes as reducing agent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yee, Foo Yiing; Malek, Sri Nurestri Abd; Periasamy, Vengadesh

    Green synthesis of gold nanoparticles (AuNPs) had been developed as an alternative to chemical and physical methods due to its simplicity, cost effectiveness and eco-friendliness. The high biocompatibility and biostability features of AuNPs have found importance in biomedical applications in recent years. In this study, aqueous ethanol extract of Curcuma mangga rhizomes which acts as reducing and stabilizing agent was used to synthesize stable AuNPs by bioreduction of chloroauric acid. The formation of AuNPs was highlighted by the color change of the suspension from light yellow to reddish purple. Time-evolution was monitored by UV-visible spectroscopy, while surface plasmon (SP) absorptionmore » band of the AuNPs suspension was observed at a maximum absorption of 540 nm. Hydrodynamic radii and size distribution of the AuNPs in the suspension were evaluated using dynamic light scattering (DLS) and zeta potential measurement demonstrated negative surface charge. The particle size was calculated in the range of 2-30 nm using High Resolution Transmission Electron Microscopy (HRTEM). The morphology and elemental composition were further determined by Field Effect Scanning Electron Microscopy (FESEM) and Energy Dispersive X-ray (EDX) spectroscopy. Fourier transform infrared (FTIR) spectroscopy meanwhile was used to confirm the presence of AuNPs and functional groups involved in the gold bio-reduction process. Influence of the volume of extract and concentration of gold (III) chloride trihydrate (HAuCl{sub 4}.3H{sub 2}O) on the synthesis of AuNPs were also investigated. The results obtained indicate potential optimization and functionalization of AuNPs for future applications in bionanotechnology especially in the field of medicine.« less

  17. Green synthesis of gold nanoparticles using aqueous ethanol extract of Curcuma mangga rhizomes as reducing agent

    NASA Astrophysics Data System (ADS)

    Yee, Foo Yiing; Periasamy, Vengadesh; Malek, Sri Nurestri Abd

    2015-04-01

    Green synthesis of gold nanoparticles (AuNPs) had been developed as an alternative to chemical and physical methods due to its simplicity, cost effectiveness and eco-friendliness. The high biocompatibility and biostability features of AuNPs have found importance in biomedical applications in recent years. In this study, aqueous ethanol extract of Curcuma mangga rhizomes which acts as reducing and stabilizing agent was used to synthesize stable AuNPs by bioreduction of chloroauric acid. The formation of AuNPs was highlighted by the color change of the suspension from light yellow to reddish purple. Time-evolution was monitored by UV-visible spectroscopy, while surface plasmon (SP) absorption band of the AuNPs suspension was observed at a maximum absorption of 540 nm. Hydrodynamic radii and size distribution of the AuNPs in the suspension were evaluated using dynamic light scattering (DLS) and zeta potential measurement demonstrated negative surface charge. The particle size was calculated in the range of 2-30 nm using High Resolution Transmission Electron Microscopy (HRTEM). The morphology and elemental composition were further determined by Field Effect Scanning Electron Microscopy (FESEM) and Energy Dispersive X-ray (EDX) spectroscopy. Fourier transform infrared (FTIR) spectroscopy meanwhile was used to confirm the presence of AuNPs and functional groups involved in the gold bio-reduction process. Influence of the volume of extract and concentration of gold (III) chloride trihydrate (HAuCl4.3H2O) on the synthesis of AuNPs were also investigated. The results obtained indicate potential optimization and functionalization of AuNPs for future applications in bionanotechnology especially in the field of medicine.

  18. Feasibility of Dynamic Stability Measurements of Planetary Entry Capsules Using MSBS

    NASA Technical Reports Server (NTRS)

    Britcher, Colin; Schoenenberger, Mark

    2015-01-01

    The feasibility of conducting dynamic stability testing of planetary entry capsules at low supersonic Mach numbers using a Magnetic Suspension and Balance System (MSBS) is reviewed. The proposed approach would employ a spherical magnetic core, exert control in three degrees-of-freedom (i.e. x, y, z translations) and allow the model to freely rotate in pitch, yaw, and roll. A proof-of-concept system using an existing MSBS electromagnet array in a subsonic wind tunnel is described, with future potential for development of a new system for a supersonic wind tunnel.

  19. Effectiveness of different Frankia cell types as inocula for the actinorhizal plant Casuarina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burleigh, S.; Torrey, J.G.

    1990-08-01

    The soil bacterium Frankia of the Actinomycetales, capable of forming N{sub 2}-fixing symbiotic root nodules on a diverse array of actinorhizal plants, has several morphological forms when grown in pure culture. Fresh hydrated preparations of whole cells, hyphae, and spores were all infective on seedlings of Casuarina at different dilutions. Desiccated hyphae showed no infection capacity, while desiccated spores remained infective, although at a reduced level. On the basis of most-probably-number statistics, spore suspensions were 3 orders of magnitude more infective than hyphae.

  20. Status of The General Atomics Low Speed Urban Maglev Technology Development Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gurol, S; Baldi, R; Bever, D

    2004-06-16

    This paper presents the status of General Atomics Urban Maglev Program. The development provides an innovative approach for low speed transportation suitable for very challenging urban environments. Permanent magnets arranged in a 'Halbach' array configuration produce a relatively stiff magnetic suspension operating with an air gap of 25 mm. The project has progressed from design and prototype hardware testing, to the construction of a 120-meter full-scale test track, located in San Diego, California. Dynamic testing of the levitation, propulsion and guidance systems is being performed.

  1. Automated Hybridization of X-ray Absorber Elements-A Path to Large Format Microcalorimeter Arrays

    NASA Technical Reports Server (NTRS)

    Moseley, S.; Kelley, R.; Allen, C.; Kilbourne, C.; Costen, N.; Miller, T.

    2007-01-01

    In the design of microcalorimeters, it is often desirable to produce the X-ray absorber separately from the detector element. In this case, the attachment of the absorber to the detector element with the required thermal and mechanical characteristics is a major challenge. In such arrays, the attachment has been done by hand. This process is not easily extended to the large format arrays required for future X- ray astronomy missions such as the New x-ray Telescope or NeXT. In this paper we present an automated process for attaching absorber tiles to the surface of a large-scale X-ray detector array. The absorbers are attached with stycast epoxy to a thermally isolating polymer structure made of SU-8. SU-8 is a negative epoxy based photo resist produced by Microchem. We describe the fabrication of the X-ray absorbers and their suspension on a handle die in an adhesive matrix. We describe the production process for the polymer isolators on the detector elements. We have developed a new process for the alignment, and simultaneous bonding of the absorber tiles to an entire detector array. This process uses equipment and techniques used in the flip-chip bonding industry and approaches developed in the fabrication of the XRS-2 instrument. XRS-2 was an X-ray spectrometer that was launched on the Suzaku telescope in July 10, 2005. We describe the process and show examples of sample arrays produced by this process. Arrays with up to 300 elements have been bonded. The present tests have used dummy absorbers made of Si. In future work, we will demonstrate bonding of HgTe absorbers.

  2. An RF phased array applicator designed for hyperthermia breast cancer treatments

    PubMed Central

    Wu, Liyong; McGough, Robert J; Arabe, Omar Ali; Samulski, Thaddeus V

    2007-01-01

    An RF phased array applicator has been constructed for hyperthermia treatments in the intact breast. This RF phased array consists of four antennas mounted on a Lexan water tank, and geometric focusing is employed so that each antenna points in the direction of the intended target. The operating frequency for this phased array is 140 MHz. The RF array has been characterized both by electric field measurements in a water tank and by electric field simulations using the finite-element method. The finite-element simulations are performed with HFSS software, where the mesh defined for finite-element calculations includes the geometry of the tank enclosure and four end-loaded dipole antennas. The material properties of the water tank enclosure and the antennas are also included in each simulation. The results of the finite-element simulations are compared to the measured values for this configuration, and the results, which include the effects of amplitude shading and phase shifting, show that the electric field predicted by finite-element simulations is similar to the measured field. Simulations also show that the contributions from standing waves are significant, which is consistent with measurement results. Simulated electric field and bio-heat transfer results are also computed within a simple 3D breast model. Temperature simulations show that, although peak temperatures are generated outside the simulated tumour target, this RF phased array applicator is an effective device for regional hyperthermia in the intact breast. PMID:16357427

  3. Carbon nanotube-based multi electrode arrays for neuronal interfacing: progress and prospects

    PubMed Central

    Bareket-Keren, Lilach; Hanein, Yael

    2013-01-01

    Carbon nanotube (CNT) coatings have been demonstrated over the past several years as a promising material for neuronal interfacing applications. In particular, in the realm of neuronal implants, CNTs have major advantages owing to their unique mechanical and electrical properties. Here we review recent investigations utilizing CNTs in neuro-interfacing applications. Cell adhesion, neuronal engineering and multi electrode recordings with CNTs are described. We also highlight prospective advances in this field, in particular, progress toward flexible, bio-compatible CNT-based technology. PMID:23316141

  4. Efficient designs for powering microscale devices with nanoscale biomolecular motors.

    PubMed

    Lin, Chih-Ting; Kao, Ming-Tse; Kurabayashi, Katsuo; Meyhöfer, Edgar

    2006-02-01

    Current MEMS and microfluidic designs require external power sources and actuators, which principally limit such technology. To overcome these limitations, we have developed a number of microfluidic systems into which we can seamlessly integrate a biomolecular motor, kinesin, that transports microtubules by extracting chemical energy from its aqueous working environment. Here we establish that our microfabricated structures, the self-assembly of the bio-derived transducer, and guided, unidirectional transport of microtubules are ideally suited to create engineered arrays for efficiently powering nano- and microscale devices.

  5. Bio-Inspired Flexible Cellular Actuating Systems

    DTIC Science & Technology

    2013-11-21

    spline . 4) Finally, the control law does not require that a, b, or M be known for the purpose of regulation. We only need to know bounds on a and M to...would have to be modeled as plates rather than beams. Although several MAV wings do have aspect ratios smaller than 3 (such as the one built by the... spline fitting. Such an array of sensors is light and cheap enough to implement in a practical setting, and more so compared with a distributed actuation

  6. Techniques for extreme attitude suspension of a wind tunnel model in a magnetic suspension and balance system. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Parker, David Huw

    1989-01-01

    Although small scale magnetic suspension and balance systems (MSBSs) for wind tunnel use have been in existence for many years, they have not found general application in the production testing of flight vehicles. One reason for this is thought to lie in the relatively limited range of attitudes over which a wind tunnel model may be suspended. Modifications to a small MSBS to permit the suspension and control of axisymmetric models over angles of attack from less than zero to over ninety degrees are reported. Previous work has shown that existing arrangement of ten electromagnets was unable to generate one of the force components needed for control at extreme attitudes. Examination of possible solutions resulted in a simple alteration to rectify this deficiency. To generate the feedback signals to control the suspended model, an optical position sensing system using collimated laser beams and photodiode arrays was installed and tested. An analytical basis was developed for distributing the demands for force and moment needed for model stabilization amonge the electromagnets over the full attitude range. This was implemented by an MSBS control program able to continually adjust the distribution for the instantaneous incidence in accordance with prescheduled data. Results presented demonstrate rotations of models from zero to ninety degrees at rates up to ninety degrees per second, with pitching rates rising to several hundred degrees per second in response to step-change demands. A study of a design for a large MSBS suggests that such a system could be given the capability to control a model in six degrees of freedom over an unlimited angle of attack range.

  7. Affinity adsorption of cells to surfaces and strategies for cell detachment.

    PubMed

    Hubble, John

    2007-01-01

    The use of bio-specific interactions for the separation and recovery of bio-molecules is now widely established and in many cases the technique has successfully crossed the divide between bench and process scale operation. Although the major specificity advantage of affinity-based separations also applies to systems intended for cell fractionation, developments in this area have been slower. Many of the problems encountered result from attempts to take techniques developed for molecular systems and, with only minor modification to the conditions used, apply them for the separation of cells. This approach tends to ignore or at least trivialise the problems, which arise from the heterogeneous nature of a cell suspension and the multivalent nature of the cell/surface interaction. To develop viable separation processes on a larger scale, effective contacting strategies are required in separators that also allow detachment or recovery protocols that overcome the enhanced binding strength generated by multivalent interactions. The effects of interaction valency on interaction strength needs to be assessed and approaches developed to allow effective detachment and recovery of adsorbed cells without compromising cell viability. This article considers the influence of operating conditions on cell attachment and the extent to which multivalent interactions determine the strength of cell binding and subsequent detachment.

  8. Rheological properties and tunable thermoplasticity of phenolic rich fraction of pyrolysis bio-oil.

    PubMed

    Sahaf, Amir; Laborie, Marie-Pierre G; Englund, Karl; Garcia-Perez, Manuel; McDonald, Armando G

    2013-04-08

    In this work we report on the preparation, characterization, and properties of a thermally treated lignin-derived, phenolic-rich fraction (PRF) of wood pyrolysis bio-oil obtained by ethyl acetate extraction. The PRF was characterized for viscoelastic and rheological behavior using dynamic mechanical analysis (DMA) and cone and plate rheology. A unique thermoplastic behavior was evidenced. Heat-treated PRFs acquire high modulus but show low temperatures of thermal flow which can be systematically manipulated through the thermal pretreatment. Loss of volatiles, changes in molecular weight, and glass transition temperature (Tg) were investigated using thermogravimetric analysis (TGA), mass spectrometry (MS), and differential scanning calorimetry (DSC), respectively. Underlying mechanisms for the thermal and rheological behavior are discussed with regard to interactions between pyrolytic lignin nanoparticles present in the system and the role of volatile materials on determining the properties of the material resembling in several aspects to colloidal suspension systems. Low thermal flow temperatures and reversible thermal effects can be attributed to association of pyrolytic lignin particles due to intermolecular interactions that are easily ruptured at higher temperatures. The thermoplastic behavior of PRF and its low Tg is of particular interest, as it gives opportunities for application of this fraction in several melt processing and adhesive technologies.

  9. Ontology-based, Tissue MicroArray oriented, image centered tissue bank

    PubMed Central

    Viti, Federica; Merelli, Ivan; Caprera, Andrea; Lazzari, Barbara; Stella, Alessandra; Milanesi, Luciano

    2008-01-01

    Background Tissue MicroArray technique is becoming increasingly important in pathology for the validation of experimental data from transcriptomic analysis. This approach produces many images which need to be properly managed, if possible with an infrastructure able to support tissue sharing between institutes. Moreover, the available frameworks oriented to Tissue MicroArray provide good storage for clinical patient, sample treatment and block construction information, but their utility is limited by the lack of data integration with biomolecular information. Results In this work we propose a Tissue MicroArray web oriented system to support researchers in managing bio-samples and, through the use of ontologies, enables tissue sharing aimed at the design of Tissue MicroArray experiments and results evaluation. Indeed, our system provides ontological description both for pre-analysis tissue images and for post-process analysis image results, which is crucial for information exchange. Moreover, working on well-defined terms it is then possible to query web resources for literature articles to integrate both pathology and bioinformatics data. Conclusions Using this system, users associate an ontology-based description to each image uploaded into the database and also integrate results with the ontological description of biosequences identified in every tissue. Moreover, it is possible to integrate the ontological description provided by the user with a full compliant gene ontology definition, enabling statistical studies about correlation between the analyzed pathology and the most commonly related biological processes. PMID:18460177

  10. Development of a High Throughput Assay for Rapid and Accurate 10-Plex Detection of Citrus Pathogens

    USDA-ARS?s Scientific Manuscript database

    The need to reliably detect and identify multiple plant pathogens simultaneously, especially in woody perennial hosts, has led to development of new molecular diagnostic approaches. In this study, a Luminex-based system was developed that provided a robust and sensitive test for simultaneous detect...

  11. Tumor Immunotherapy by Gene-circuit Recruited Immunomodulatory Systems (TIGRIS) for Prostate Cancer

    DTIC Science & Technology

    2017-09-01

    Fu, X., Huang, W., and Cai, Z. (2014). Syn- thesizing AND gate genetic circuits based on CRISPR -Cas9 for identification of bladder cancer cells. Nat...and Lu, T.K. (2014). Multi- plexed and programmable regulation of gene networks with an integrated RNA and CRISPR /Cas toolkit in human cells. Mol

  12. Investigation of heterogeneous ice nucleation in pollen suspensions and washing water

    NASA Astrophysics Data System (ADS)

    Dreischmeier, Katharina; Budke, Carsten; Koop, Thomas

    2014-05-01

    Biological particles such as pollen often show ice nucleation activity at temperatures higher than -20 °C. Immersion freezing experiments of pollen washing water demonstrate comparable ice nucleation behaviour as water containing the whole pollen bodies (Pummer et al., 2012). It was suggested that polysaccharide molecules leached from the grains are responsible for the ice nucleation. Here, heterogeneous ice nucleation in birch pollen suspensions and their washing water was investigated by two different experimental methods. The optical freezing array BINARY (Bielefeld Ice Nucleation ARraY) allows the direct observation of freezing of microliter-sized droplets. The IN spectra obtained from such experiments with birch pollen suspensions over a large concentration range indicate several different ice nucleation active species, two of which are present also in the washing water. The latter was probed also in differential scanning calorimeter (DSC) experiments of emulsified sub-picoliter droplets. Due to the small droplet size in the emulsion samples and at small concentration of IN in the washing water, such DSC experiments can exhibit the ice nucleation behaviour of a single nucleus. The two heterogeneous freezing signals observed in the DSC thermograms can be assigned to two different kinds of ice nuclei, confirming the observation from the BINARY measurements, and also previous studies on Swedish birch pollen washing water (Augustin et al., 2012). The authors gratefully acknowledge funding by the German Research Foundation (DFG) through the project BIOCLOUDS (KO 2944/1-1) and through the research unit INUIT (FOR 1525) under KO 2944/2-1. We particularly thank our INUIT partners for fruitful collaboration and sharing of ideas and IN samples. S. Augustin, H. Wex, D. Niedermeier, B. Pummer, H. Grothe, S. Hartmann, L. Tomsche, T. Clauss, J. Voigtländer, K. Ignatius, and F. Stratmann, Immersion freezing of birch pollen washing water, Atmos. Chem. Phys., 13, 10989-11003, 2013. B. Pummer, H Bauer, J. Bernardi, S. Bleicher, H. Grothe, Suspendable macromolecules are responsible for ice nucleation activity of birch and conifer pollen, Atmos. Chem. Phys., 12, 2541-2550, 2012.

  13. Multiplex Allele-Specific Amplification from Whole Blood for Detecting Multiple Polymorphisms Simultaneously

    PubMed Central

    Zhu, Jianjie; Chen, Lanxin; Mao, Yong; Zhou, Huan

    2013-01-01

    Allele-specific amplification on the basis of polymerase chain reaction (PCR) has been widely used for single-nucleotide polymorphism (SNP) genotyping. However, the extraction of PCR-compatible genomic DNA from whole blood is usually required. This process is complicated and tedious, and is prone to cause cross-contamination between samples. To facilitate direct PCR amplification from whole blood without the extraction of genomic DNA, we optimized the pH value of PCR solution and the concentrations of magnesium ions and facilitator glycerol. Then, we developed multiplex allele-specific amplifications from whole blood and applied them to a case–control study. In this study, we successfully established triplex, five-plex, and eight-plex allele-specific amplifications from whole blood for determining the distribution of genotypes and alleles of 14 polymorphisms in 97 gastric cancer patients and 141 healthy controls. Statistical analysis results showed significant association of SNPs rs9344, rs1799931, and rs1800629 with the risk of gastric cancer. This method is accurate, time-saving, cost-effective, and easy-to-do, especially suitable for clinical prediction of disease susceptibility. PMID:23072573

  14. [Analysis of genetic polymorphisms and mutations of 20 frequently used STR loci among ethnic Hans from Henan].

    PubMed

    Wang, Hongdan; Kang, Bing; Gao, Yue; Huo, Xiaodong; Li, Tao; Guo, Qiannan; Zhu, Bofeng; Liao, Shixiu

    2017-04-10

    To study the genetic polymorphisms and mutations of 20 frequently used autosomal microsatellites among ethnic Hans from Henan. Peripheral blood samples of 2604 individuals were collected. DNA was amplified and genotyped using a PowerPlex(TM) 21 system. The frequencies, forensic parameters and mutation rates of the 20 short tandem repeat (STR) loci were analyzed. A total of 323 alleles were found in this population and the allelic frequencies have ranged from 0.0003 to 0.5144. Except for D3S1358, TH01 and TPOX, mutations have been found in all of the remaining 17 STR loci, which totaled 47, with mutation rates ranging from 0 to 3.46 × 10 -3 . The 20 STR loci selected by the PowerPlex(TM) 21 system are highly polymorphic among ethnic Hans from Henan, and may be of great value in forensic and human population studies. As no similar study has been carried out previously, above results may be of great value for individual discrimination and paternal testing.

  15. DNA Identification of Commingled Human Remains from the Cemetery Relocated by Flooding in Central Bosnia and Herzegovina.

    PubMed

    Čakar, Jasmina; Pilav, Amela; Džehverović, Mirela; Ahatović, Anesa; Haverić, Sanin; Ramić, Jasmin; Marjanović, Damir

    2018-01-01

    The floods in Bosnia and Herzegovina in May 2014 caused landslides all over the country. In the small village of Šerići, near the town of Zenica, a landslide destroyed the local cemetery, relocated graves, and commingled skeletal remains. As the use of other physical methods of identification (facial recognition, fingerprint analysis, dental analysis, etc.) was not possible, DNA analysis was applied. DNA was isolated from 20 skeletal remains (bone and tooth samples) and six reference samples (blood from living relatives) and amplified using PowerPlex ® Fusion and PowerPlex ® Y23 kits. DNA profiles were generated for all reference samples and 17 skeletal remains. A statistical analysis (calculation of paternity, maternity, and sibling indexes and matching probabilities) resulted in 10 positive identifications. In this study, 5 individuals were identified based on one reference sample. This has once again demonstrated the significance of DNA analysis in resolving the most complicated cases, such as the identification of commingled human skeletal remains. © 2017 American Academy of Forensic Sciences.

  16. Modular nucleic acid assembled p/MHC microarrays for multiplexed sorting of antigen-specific T cells.

    PubMed

    Kwong, Gabriel A; Radu, Caius G; Hwang, Kiwook; Shu, Chengyi J; Ma, Chao; Koya, Richard C; Comin-Anduix, Begonya; Hadrup, Sine Reker; Bailey, Ryan C; Witte, Owen N; Schumacher, Ton N; Ribas, Antoni; Heath, James R

    2009-07-22

    The human immune system consists of a large number of T cells capable of recognizing and responding to antigens derived from various sources. The development of peptide-major histocompatibility (p/MHC) tetrameric complexes has enabled the direct detection of these antigen-specific T cells. With the goal of increasing throughput and multiplexing of T cell detection, protein microarrays spotted with defined p/MHC complexes have been reported, but studies have been limited due to the inherent instability and reproducibility of arrays produced via conventional spotted methods. Herein, we report on a platform for the detection of antigen-specific T cells on glass substrates that offers significant advantages over existing surface-bound schemes. In this approach, called "Nucleic Acid Cell Sorting (NACS)", single-stranded DNA oligomers conjugated site-specifically to p/MHC tetramers are employed to immobilize p/MHC tetramers via hybridization to a complementary-printed substrate. Fully assembled p/MHC arrays are used to detect and enumerate T cells captured from cellular suspensions, including primary human T cells collected from cancer patients. NACS arrays outperform conventional spotted arrays assessed in key criteria such as repeatability and homogeneity. The versatility of employing DNA sequences for cell sorting is exploited to enable the programmed, selective release of target populations of immobilized T cells with restriction endonucleases for downstream analysis. Because of the performance, facile and modular assembly of p/MHC tetramer arrays, NACS holds promise as a versatile platform for multiplexed T cell detection.

  17. RDFBuilder: a tool to automatically build RDF-based interfaces for MAGE-OM microarray data sources.

    PubMed

    Anguita, Alberto; Martin, Luis; Garcia-Remesal, Miguel; Maojo, Victor

    2013-07-01

    This paper presents RDFBuilder, a tool that enables RDF-based access to MAGE-ML-compliant microarray databases. We have developed a system that automatically transforms the MAGE-OM model and microarray data stored in the ArrayExpress database into RDF format. Additionally, the system automatically enables a SPARQL endpoint. This allows users to execute SPARQL queries for retrieving microarray data, either from specific experiments or from more than one experiment at a time. Our system optimizes response times by caching and reusing information from previous queries. In this paper, we describe our methods for achieving this transformation. We show that our approach is complementary to other existing initiatives, such as Bio2RDF, for accessing and retrieving data from the ArrayExpress database. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  18. Chemical modification of TiO2 nanotube arrays for label-free optical biosensing applications

    NASA Astrophysics Data System (ADS)

    Terracciano, Monica; Galstyan, Vardan; Rea, Ilaria; Casalino, Maurizio; De Stefano, Luca; Sbervegleri, Giorgio

    2017-10-01

    In this study, we have fabricated TiO2 nanotube arrays by the potentiostatic anodic oxidation of Ti foils in fluoride-containing electrolyte and explored them as versatile devices for biosensing applications. TiO2 nanotubes have been chemically modified in order to bind Protein A as a specific target analyte for the optical biosensing. The obtained structures have been characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, water contact angle, fluorescence microscopy, spectroscopic reflectometry and photoluminescence. Investigations show that the prepared TiO2 nanotubes, 2.5 μm long and 75 nm thick, can be easily and efficiently bio-modified, and the obtained structures are strongly photoluminescent, thus suitable for the label-free biosensing applications in the range of μM, due to their peculiar optical properties.

  19. Polystyrene Core-Silica Shell Particles with Defined Nanoarchitectures as a Versatile Platform for Suspension Array Technology.

    PubMed

    Sarma, Dominik; Gawlitza, Kornelia; Rurack, Knut

    2016-04-19

    The need for rapid and high-throughput screening in analytical laboratories has led to significant growth in interest in suspension array technologies (SATs), especially with regard to cytometric assays targeting a low to medium number of analytes. Such SAT or bead-based assays rely on spherical objects that constitute the analytical platform. Usually, functionalized polymer or silica (SiO2) microbeads are used which each have distinct advantages and drawbacks. In this paper, we present a straightforward synthetic route to highly monodisperse SiO2-coated polystyrene core-shell (CS) beads for SAT with controllable architectures from smooth to raspberry- and multilayer-like shells by varying the molecular weight of poly(vinylpyrrolidone) (PVP), which was used as the stabilizer of the cores. The combination of both organic polymer core and a structurally controlled inorganic SiO2 shell in one hybrid particle holds great promises for flexible next-generation design of the spherical platform. The particles were characterized by electron microscopy (SEM, T-SEM, and TEM), thermogravimetry, flow cytometry, and nitrogen adsorption/desorption, offering comprehensive information on the composition, size, structure, and surface area. All particles show ideal cytometric detection patterns and facile handling due to the hybrid structure. The beads are endowed with straightforward modification possibilities through the defined SiO2 shells. We successfully implemented the particles in fluorometric SAT model assays, illustrating the benefits of tailored surface area which is readily available for small-molecule anchoring. Very promising assay performance was shown for DNA hybridization assays with quantification limits down to 8 fmol.

  20. Evaluation of suspension array analysis for detection of egg yolk antibodies against Salmonella Enteritidis.

    PubMed

    Thomas, M E; Klinkenberg, D; Bergwerff, A A; van Eerden, E; Stegeman, J A; Bouma, A

    2010-06-01

    Salmonella enterica serovar Enteritidis (SE) is an important source of food-related diarrhoea in humans, and table eggs are considered the primordial source of contamination of the human food chain. Using eggs collected at egg-packing stations as samples could be a convenient strategy to detect colonization of layer flocks. The aim of this study was to evaluate egg yolk anti-Salmonella antibody detection using suspension array analysis. An egg yolk panel from contact-infected and non-colonized laying hens was used for the evaluation. Receiver Operating Characteristic (ROC) curves were generated to define a cut-off value and to assess the overall accuracy of the assay. The diagnostic sensitivity and specificity were estimated by maximum likelihood. Sensitivity was quantified on hen level and on sample level, and also quantified as a function of time since colonization. The area under the ROC curve was estimated at 0.984 (se 0.006, P<0.001). Of all colonized contact-infected hens, 67.6% [95% CI: 46.8, 100] developed an antibody response, which was detectable 17.4 days [14.3, 26.9] after colonization. In total, 98% [95.4, 99.4] of the 'immunopositive' hens had test positive eggs. The overall sensitivity of the immunological test was 66.7% [45.9, 98.7] and the specificity was 98.5% [97.8, 99.1]. This study provided essential parameters for optimizing surveillance programs based on detection of antibodies, and indicates that immunology based on examination of egg yolk gives important information about the Salmonella status of the flock. (c) 2010 Elsevier B.V. All rights reserved.

  1. Serum amyloid A induction of cytokines in monocytes/macrophages and lymphocytes.

    PubMed

    Song, Changjie; Hsu, Kenneth; Yamen, Eric; Yan, Weixing; Fock, Jianyi; Witting, Paul K; Geczy, Carolyn L; Freedman, S Ben

    2009-12-01

    Serum amyloid A (SAA) is a biomarker of inflammation. Elevated blood levels in cardiovascular disease and local deposition in atheroma implies a role of SAA as a mediator rather than just a marker of inflammation. This study explored SAA-induced cytokine production and secretion by mononuclear cells. RT-PCR showed that SAA time-dependently induced cytokine mRNAs in peripheral blood mononuclear cells (PBMC) and THP-1 monocytoid cells, and dramatically increased IL-1beta, MCP-1, IL-6, IL-8, IL-10, GM-CSF, TNF, and MIP-1alpha secretion by PBMC to levels 28 to 25,000 fold above baseline, as measured with Bio-Plex kits; monocytes were the principle source. SAA induction of cytokines in monocyte-derived macrophages (MDM) was significantly higher than from monocytes from the same donors. SAA time-dependently induced transient and significant upregulation of NF-kappaB1 mRNA; inhibitor studies indicate that activation of NF-kappaB through the ERK1/2, p38 and JNK MAPKs and the PI3K pathway was involved. PBMC from 10 patients with coronary artery disease (CAD) spontaneously secreted higher levels of IL-6 and MIP-1alpha after 24h incubation than PBMC from normal controls, whereas SAA-induced levels of all cytokines were similar to controls. Aortic and coronary sinus sampling in 23 CAD patients indicated significant SAA release into the coronary circulation, not evident in 11 controls. SAA can increase monocyte and macrophage cytokine production, possibly at sites of atherosclerosis, thereby contributing to the pro-inflammatory state in coronary artery disease.

  2. Effect of non-tuberculous Mycobacteria on host biomarkers potentially relevant for tuberculosis management.

    PubMed

    Dhanasekaran, S; Jenum, Synne; Stavrum, Ruth; Wiker, Harald G; Kenneth, John; Vaz, Mario; Doherty, T Mark; Grewal, Harleen M S

    2014-10-01

    Non-tuberculous mycobacteria (NTM) are different from Mycobacterium tuberculosis (MTB) both in their ubiquitous environmental distribution and in their reduced capacity to cause disease. While often neglected in favour of other infectious diseases, NTM may interfere with important aspects of TB control and management, namely the efficacy of new anti-tuberculosis (TB) vaccines; the immuno-diagnostic Tuberculin skin test (TST) and QuantiFERON TB Gold In Tube assay (QFTGIT); and immune biomarkers explored for their diagnostic and/or predictive potential. Our objective was therefore to explore host immune biomarkers in children who had NTM isolated from respiratory and/or gastric specimens. The present study was nested within a prospective cohort study of BCG-vaccinated neonates in Southern India. In this setting, immune biomarkers from peripheral blood were analyzed in 210 children aged <3 years evaluated for TB using dual-colour-Reverse-Transcriptase-Multiple-Ligation-dependent-Probe-Amplification (dcRT-MLPA) and Bio-Plex assays. The children were classified based on clinical examination, chest X-rays and mycobacterial culture reports as either: 1) TB disease, 2) NTM present and 3) controls. The study shows a down-regulation of RAB33A (p<0.001) and up-regulation of TGFβ1, IL-2 and IL-6 (all p<0.05) in children with TB disease, and that RAB33A, TGFBR2 and IL-10 (all p<0.05) were differentially expressed in children with NTM present when compared to children that were culture negative for MTB and NTM (controls). Carriage of NTM may reduce the specificity of future diagnostic and predictive immune biomarkers relevant to TB management.

  3. Fibromyalgia: anti-inflammatory and stress responses after acute moderate exercise.

    PubMed

    Bote, Maria Elena; Garcia, Juan Jose; Hinchado, Maria Dolores; Ortega, Eduardo

    2013-01-01

    Fibromyalgia (FM) is characterized in part by an elevated inflammatory status, and "modified exercise" is currently proposed as being a good therapeutic help for these patients. However, the mechanisms involved in the exercise-induced benefits are still poorly understood. The objective was to evaluate the effect of a single bout of moderate cycling (45 min at 55% VO2 max) on the inflammatory (serum IL-8; chemotaxis and O2 (-) production by neutrophils; and IL-1β, TNF-α, IL-6, IL-10, and IL-18 release by monocytes) and stress (cortisol; NA; and eHsp72) responses in women diagnosed with FM compared with an aged-matched control group of healthy women (HW). IL-8, NA, and eHsp72 were determined by ELISA. Cytokines released by monocytes were determined by Bio-Plex® system (LUMINEX). Cortisol was determined by electrochemoluminiscence, chemotaxis was evaluated in Boyden chambers and O2 (-) production by NBT reduction. In the FM patients, the exercise induced a decrease in the systemic concentration of IL-8, cortisol, NA, and eHsp72; as well as in the neutrophil's chemotaxis and O2 (-) production and in the inflammatory cytokine release by monocytes. This was contrary to the completely expected exercise-induced increase in all those biomarkers in HW. In conclusion, single sessions of moderate cycling can improve the inflammatory status in FM patients, reaching values close to the situation of aged-matched HW at their basal status. The neuroendocrine mechanism seems to be an exercise-induced decrease in the stress response of these patients.

  4. Broncho-Vaxom Attenuates Allergic Airway Inflammation by Restoring GSK3β-Related T Regulatory Cell Insufficiency

    PubMed Central

    Zhong, Hua; Yu, Dehong; Zeng, Xianping; Deng, Mengxia; Sun, Yueqi; Wen, Weiping; Li, Huabin

    2014-01-01

    Background Oral administration of bacterial extracts (eg, Broncho-Vaxom (BV)) has been proposed to attenuate asthma through modulating Treg cells. However, the underlying mechanism has not been fully characterized. This study sought to assess the effects of oral administration of BV on GSK-3β expression and Treg cells in ovalbumin (OVA)-induced asthmatic mice models. Method Asthmatic mice models were established with OVA challenge and treated with oral administration of BV. Next, infiltration of inflammatory cells including eosinophil and neutrophils, mucous metaplasia, levels of Th1/Th2/Treg-typed cytokines and expression of GSK3β and Foxp3 were examined in asthmatic mice models by histological analysis, Bio-Plex and western blot, respectively. Moreover, the frequencies of Treg cells were evaluated in cultured splenocytes by flow cytometry in the presence of BV or GSK3β siRNA interference. Results We found significant decrease of infiltrated inflammatory cells in bronchoalveolar lavage fluid (BALF) in asthmatic mice models after oral administration of BV. Oral administration of BV was shown to significantly suppress mucus metaplasia, Th2-typed cytokine levels and GSK3β expression while increasing Foxp3 production in asthmatic mice models. Moreover, BV significantly enhanced GSK3β-related expansion of Treg cells in cultured spleen cells in vitro. Conclusion Our findings provide evidence that oral administration of BV is capable of attenuating airway inflammation in asthmatic mice models, which may be associated with GSK3β-related expansion of Treg cells. PMID:24667347

  5. Reduced immune responses to purified protein derivative and Candida albicans in oral lichen planus.

    PubMed

    Simark-Mattsson, Charlotte; Eklund, Christina

    2013-10-01

    Impairment of cellular immunity is reported in lichen planus, an autoimmune disease affecting mucosae and skin. Our aim was to investigate immune responses directed against a set of microbial antigens in patients with oral lichen planus and in matched controls. Venous blood was obtained, and the mononuclear cells were enriched by density gradient centrifugation. The proliferation of peripheral blood mononuclear cells was assessed, following stimulation with purified protein derivative (PPD), Candida albicans, phytohemagglutinin or when cells were left unstimulated, after three or six days of cell culture. The production of interleukin-1ß (IL-1ß), IL-2, IL-4, IL-5, IL-6, IL-10, IL-12, IL-13, IL-17, interferon-γ (IFN-γ), tumour necrosis factor-α (TNF-α), G-CSF, GM-CSF, MCP-1, MIP-ß was assessed in supernatants using the Bio-plex(®) assay and was complemented with ELISA for selected cytokines. Patients with oral lichen planus demonstrated reduced proliferative responses against PPD (P < 0.05) and C. albicans (P < 0.05). The majority of investigated cytokines, including the pro-inflammatory, IFN-γ and TNF-α were expressed at reduced levels in PPD-stimulated supernatants from patients with oral lichen planus. Collectively, the findings suggested that memory lymphocytes from patients with oral lichen planus (OLP) may have an impaired functional ability to react against certain recall antigens, as part of a generalized response, which may reflect immune regulatory processes. Further studies are needed to clarify the mechanisms of down-regulation in OLP pathogenesis and progression. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Comparison of low-abundance biomarker levels in capillary-collected nonstimulated tears and washout tears of aqueous-deficient and normal patients.

    PubMed

    Guyette, Nicole; Williams, Larezia; Tran, My-Tho; Than, Tammy; Bradley, John; Kehinde, Lucy; Edwards, Clara; Beasley, Mark; Fullard, Roderick

    2013-05-01

    Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 μL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.

  7. Relation of sensory peripheral neuropathy in Sjögren syndrome to anti-Ro/SSA.

    PubMed

    Scofield, Amanda Kyle; Radfar, Lida; Ice, John A; Vista, Evan; Anaya, Juan-Manuel; Houston, Glen; Lewis, David; Stone, Donald U; Chodosh, James; Hefner, Kimberly; Lessard, Christopher J; Moser, Kathy L; Scofield, Robert Hal

    2012-09-01

    Sjögren syndrome is a common, chronic autoimmune disease that typically produces inflammation and poor function of the salivary and lacrimal glands. Other organs can be affected, including the nervous system. Sensory peripheral neuropathy is a common manifestation of the disease. Eight-eight patients attending a dry eyes-dry mouth clinic were diagnosed to have primary Sjögren syndrome and underwent a neurological examination. Anti-Ro (or SSA) and anti-La (or SSB) were determined using immunodiffusion as well as Inno-Lia and BioPlex ANA screen. Serum vitamin B(12) levels were determined using an enzyme-linked microtiter plate assay. Twenty-seven (31%) of the 88 patients had peripheral neuropathy as defined by loss of light touch, proprioception, or vibratory sensation. Anti-Ro and anti-La were found by immunodiffusion in 12 patients, and 8 of these 12 had neuropathy (χ(2) = 8.46, P = 0.0036, odds ratio = 6.0 compared to those without precipitating anti-Ro and anti-La). Of the 27 patients with only anti-Ro by immunodiffusion, 13 (48.1%) had neuropathy (χ(2) = 5.587, P = 0.018, compared to those without anti-Ro). There was no relationship of the other, more sensitive measures of anti-Ro and anti-La to neuropathy. In addition, we found no association of serum vitamin B(12) levels to neuropathy among these patients with Sjögren syndrome. Sensory peripheral neuropathy is common among patients with Sjögren syndrome and is associated with the presence of anti-Ro and anti-La when determined by immunodiffusion.

  8. Biomarkers and insulin sensitivity in women with Polycystic Ovary Syndrome: Characteristics and predictive capacity.

    PubMed

    Cassar, Samantha; Teede, Helena J; Harrison, Cheryce L; Joham, Anju E; Moran, Lisa J; Stepto, Nigel K

    2015-07-01

    Polycystic ovary syndrome (PCOS) is a common endocrine disorder associated with metabolic complications. Metabolic biomarkers with roles in obesity, glycaemic control and lipid metabolism are potentially relevant in PCOS. The aim was to investigate metabolic biomarkers in lean and overweight women with and without PCOS and to determine whether any biomarker was able to predict insulin resistance in PCOS. Cross-sectional study. Eighty-four women (22 overweight and 22 lean women with PCOS, 18 overweight and 22 lean women without PCOS) were recruited from the community and categorized based on PCOS and BMI status. Primary outcomes were metabolic biomarkers [ghrelin, resistin, visfatin, glucagon-like peptide-1 (GLP-1), leptin, plasminogen activator inhibitor -1 (PAI-1), glucose-dependent insulinotropic polypeptide (GIP) and C-Peptide] measured using the Bio-Plex Pro Diabetes assay and insulin sensitivity as assessed by glucose infusion rate on euglycaemic-hyperinsulinaemic clamp. The biomarkers C-peptide, leptin, ghrelin and visfatin were different between overweight and lean women, irrespective of PCOS status. The concentration of circulating biomarkers did not differ between women with PCOS diagnosed by the Rotterdam criteria or National Institute of Health criteria. PAI-1 was the only biomarker that significantly predicted insulin resistance in both control women (P = 0.04) and women with PCOS (P = 0.01). Biomarkers associated with metabolic diseases appear more strongly associated with obesity rather than PCOS status. PAI-1 may also be a novel independent biomarker and predictor of insulin resistance in women with and without PCOS. © 2014 John Wiley & Sons Ltd.

  9. Multi-Dimensional Measurement of Antibody-Mediated Heterosubtypic Immunity to Influenza.

    PubMed

    Wang, Jiong; Hilchey, Shannon P; Hyrien, Ollivier; Huertas, Nelson; Perry, Sheldon; Ramanunninair, Manojkumar; Bucher, Doris; Zand, Martin S

    2015-01-01

    The human immune response to influenza vaccination depends in part on preexisting cross-reactive (heterosubtypic) immunity from previous infection by, and/or vaccination with, influenza strains that share antigenic determinants with the vaccine strains. However, current methods for assessing heterosubtypic antibody responses against influenza, including the hemagglutination-inhibition (HAI) assay and ELISA, are time and labor intensive, and require moderate amounts of serum and reagents. To address these issues we have developed a fluorescent multiplex assay, mPlex-Flu, that rapidly and simultaneously measures strain specific IgG, IgA, and IgM antibodies against influenza hemagglutinin (HA) from multiple viral strains. We cloned, expressed and purified HA proteins from 12 influenza strains, and coupled them to multiplex beads. Assay validation showed that minimal sample volumes (<5 μl of serum) were needed, and the assay had a linear response over a four Log10 range. The assay detected nanogram levels of anti-influenza specific antibodies, had high accuracy and reproducibility, with an average percentage coefficient of variation (%CV) of 9.06 for intra-assay and 12.94 for inter-assay variability. Pre- and post-intramuscular trivalent influenza vaccination levels of virus specific Ig were consistent with HAI titer and ELISA measurements. A significant advantage of the mPLEX-Flu assay over the HAI assay is the ability to perform antigenic cartography, determining the antigenic distances between influenza HA's, without mathematical correction for HAI data issues. For validation we performed antigenic cartography on 14 different post-influenza infection ferret sera assayed against 12 different influenza HA's. Results were in good agreement with a phylogenetic tree generated from hierarchical clustering of the genomic HA sequences. This is the first report of the use of a multiplex method for antigenic cartography using ferret sera. Overall, the mPlex-Flu assay provides a powerful tool to rapidly assess the influenza antibody repertoire in large populations and to study heterosubtypic immunity induced by influenza vaccination.

  10. Factors Predicting Risk for Antibody-mediated Rejection and Graft Loss in Highly Human Leukocyte Antigen Sensitized Patients Transplanted After Desensitization.

    PubMed

    Vo, Ashley A; Sinha, Aditi; Haas, Mark; Choi, Jua; Mirocha, James; Kahwaji, Joseph; Peng, Alice; Villicana, Rafael; Jordan, Stanley C

    2015-07-01

    Desensitization with intravenous immunoglobulin and rituximab (I+R) significantly improves transplant rates in highly sensitized patients, but antibody-mediated rejection (ABMR) remains a concern. Between July 2006 and December 2012, 226 highly sensitized patients received transplants after desensitization. Most received alemtuzumab induction and standard immunosuppression. Two groups were examined: ABMR (n = 181) and ABMR (n = 45, 20%). Risk factors for ABMR, pathology, and outcomes were assessed. Significant risks for ABMR included previous transplants and pregnancies as sensitizing events, donor-specific antibody (DSA) relative intensity scores greater than 17, presence of both class I and II DSAs at transplant and time on waitlist. The ABMR showed a significant benefit for graft survival and glomerular filtration rate at 5 years (P < 0.0001). Banff pathology characteristics for ABMR patients with or without graft loss did not differ. C4d versus C4d ABMR did not predict graft loss (P = 0.086). Thrombotic microangiopathy (TMA) significantly predicted graft failure (P = 0.045). The ABMR episodes were treated with I+R (n = 25), or, in more severe ABMR, plasma exchange (PLEX)+I+R (n = 20). Graft survival for patients treated with I+R was superior (P = 0.028). Increased mortality was seen in ABMR patients experiencing graft loss after ABMR treatment (P = 0.004). The PLEX + Eculizumab improved graft survival for TMA patients (P = 0.036). Patients desensitized with I+R who remain ABMR have long-term graft and patient survival. The ABMR patients have significantly reduced graft survival and glomerular filtration rate at 5 years, especially TMA. Severe ABMR episodes benefit from treatment with PLEX + Eculizumab. The DSA-relative intensity scores at transplant was a strong predictor of ABMR. Donor-specific antibody avoidance and reduction strategies before transplantation are critical to avoiding ABMR and improving long-term outcomes.

  11. Development of a genetic tool for product regulation in the diverse British pig breed market.

    PubMed

    Wilkinson, Samantha; Archibald, Alan L; Haley, Chris S; Megens, Hendrik-Jan; Crooijmans, Richard P M A; Groenen, Martien A M; Wiener, Pamela; Ogden, Rob

    2012-11-15

    The application of DNA markers for the identification of biological samples from both human and non-human species is widespread and includes use in food authentication. In the food industry the financial incentive to substituting the true name of a food product with a higher value alternative is driving food fraud. This applies to British pork products where products derived from traditional pig breeds are of premium value. The objective of this study was to develop a genetic assay for regulatory authentication of traditional pig breed-labelled products in the porcine food industry in the United Kingdom. The dataset comprised of a comprehensive coverage of breed types present in Britain: 460 individuals from 7 traditional breeds, 5 commercial purebreds, 1 imported European breed and 1 imported Asian breed were genotyped using the PorcineSNP60 beadchip. Following breed-informative SNP selection, assignment power was calculated for increasing SNP panel size. A 96-plex assay created using the most informative SNPs revealed remarkably high genetic differentiation between the British pig breeds, with an average FST of 0.54 and Bayesian clustering analysis also indicated that they were distinct homogenous populations. The posterior probability of assignment of any individual of a presumed origin actually originating from that breed given an alternative breed origin was > 99.5% in 174 out of 182 contrasts, at a test value of log(LR) > 0. Validation of the 96-plex assay using independent test samples of known origin was successful; a subsequent survey of market samples revealed a high level of breed label conformity. The newly created 96-plex assay using selected markers from the PorcineSNP60 beadchip enables powerful assignment of samples to traditional breed origin and can effectively identify mislabelling, providing a highly effective tool for DNA analysis in food forensics.

  12. Development of a genetic tool for product regulation in the diverse British pig breed market

    PubMed Central

    2012-01-01

    Background The application of DNA markers for the identification of biological samples from both human and non-human species is widespread and includes use in food authentication. In the food industry the financial incentive to substituting the true name of a food product with a higher value alternative is driving food fraud. This applies to British pork products where products derived from traditional pig breeds are of premium value. The objective of this study was to develop a genetic assay for regulatory authentication of traditional pig breed-labelled products in the porcine food industry in the United Kingdom. Results The dataset comprised of a comprehensive coverage of breed types present in Britain: 460 individuals from 7 traditional breeds, 5 commercial purebreds, 1 imported European breed and 1 imported Asian breed were genotyped using the PorcineSNP60 beadchip. Following breed-informative SNP selection, assignment power was calculated for increasing SNP panel size. A 96-plex assay created using the most informative SNPs revealed remarkably high genetic differentiation between the British pig breeds, with an average FST of 0.54 and Bayesian clustering analysis also indicated that they were distinct homogenous populations. The posterior probability of assignment of any individual of a presumed origin actually originating from that breed given an alternative breed origin was > 99.5% in 174 out of 182 contrasts, at a test value of log(LR) > 0. Validation of the 96-plex assay using independent test samples of known origin was successful; a subsequent survey of market samples revealed a high level of breed label conformity. Conclusion The newly created 96-plex assay using selected markers from the PorcineSNP60 beadchip enables powerful assignment of samples to traditional breed origin and can effectively identify mislabelling, providing a highly effective tool for DNA analysis in food forensics. PMID:23150935

  13. Multi-Dimensional Measurement of Antibody-Mediated Heterosubtypic Immunity to Influenza

    PubMed Central

    Wang, Jiong; Hilchey, Shannon P.; Hyrien, Ollivier; Huertas, Nelson; Perry, Sheldon; Ramanunninair, Manojkumar; Bucher, Doris; Zand, Martin S.

    2015-01-01

    The human immune response to influenza vaccination depends in part on preexisting cross-reactive (heterosubtypic) immunity from previous infection by, and/or vaccination with, influenza strains that share antigenic determinants with the vaccine strains. However, current methods for assessing heterosubtypic antibody responses against influenza, including the hemagglutination-inhibition (HAI) assay and ELISA, are time and labor intensive, and require moderate amounts of serum and reagents. To address these issues we have developed a fluorescent multiplex assay, mPlex-Flu, that rapidly and simultaneously measures strain specific IgG, IgA, and IgM antibodies against influenza hemagglutinin (HA) from multiple viral strains. We cloned, expressed and purified HA proteins from 12 influenza strains, and coupled them to multiplex beads. Assay validation showed that minimal sample volumes (<5 μl of serum) were needed, and the assay had a linear response over a four Log10 range. The assay detected nanogram levels of anti-influenza specific antibodies, had high accuracy and reproducibility, with an average percentage coefficient of variation (%CV) of 9.06 for intra-assay and 12.94 for inter-assay variability. Pre- and post-intramuscular trivalent influenza vaccination levels of virus specific Ig were consistent with HAI titer and ELISA measurements. A significant advantage of the mPLEX-Flu assay over the HAI assay is the ability to perform antigenic cartography, determining the antigenic distances between influenza HA’s, without mathematical correction for HAI data issues. For validation we performed antigenic cartography on 14 different post-influenza infection ferret sera assayed against 12 different influenza HA’s. Results were in good agreement with a phylogenetic tree generated from hierarchical clustering of the genomic HA sequences. This is the first report of the use of a multiplex method for antigenic cartography using ferret sera. Overall, the mPlex-Flu assay provides a powerful tool to rapidly assess the influenza antibody repertoire in large populations and to study heterosubtypic immunity induced by influenza vaccination. PMID:26103163

  14. Further evidence for population specific differences in the effect of DNA markers and gender on eye colour prediction in forensics.

    PubMed

    Pośpiech, Ewelina; Karłowska-Pik, Joanna; Ziemkiewicz, Bartosz; Kukla, Magdalena; Skowron, Małgorzata; Wojas-Pelc, Anna; Branicki, Wojciech

    2016-07-01

    The genetics of eye colour has been extensively studied over the past few years, and the identified polymorphisms have been applied with marked success in the field of Forensic DNA Phenotyping. A picture that arises from evaluation of the currently available eye colour prediction markers shows that only the analysis of HERC2-OCA2 complex has similar effectiveness in different populations, while the predictive potential of other loci may vary significantly. Moreover, the role of gender in the explanation of human eye colour variation should not be neglected in some populations. In the present study, we re-investigated the data for 1020 Polish individuals and using neural networks and logistic regression methods explored predictive capacity of IrisPlex SNPs and gender in this population sample. In general, neural networks provided higher prediction accuracy comparing to logistic regression (AUC increase by 0.02-0.06). Four out of six IrisPlex SNPs were associated with eye colour in the studied population. HERC2 rs12913832, OCA2 rs1800407 and SLC24A4 rs12896399 were found to be the most important eye colour predictors (p < 0.007) while the effect of rs16891982 in SLC45A2 was less significant. Gender was found to be significantly associated with eye colour with males having ~1.5 higher odds for blue eye colour comparing to females (p = 0.002) and was ranked as the third most important factor in blue/non-blue eye colour determination. However, the implementation of gender into the developed prediction models had marginal and ambiguous impact on the overall accuracy of prediction confirming that the effect of gender on eye colour in this population is small. Our study indicated the advantage of neural networks in prediction modeling in forensics and provided additional evidence for population specific differences in the predictive importance of the IrisPlex SNPs and gender.

  15. Laser-induced superhydrophobic grid patterns on PDMS for droplet arrays formation

    NASA Astrophysics Data System (ADS)

    Farshchian, Bahador; Gatabi, Javad R.; Bernick, Steven M.; Park, Sooyeon; Lee, Gwan-Hyoung; Droopad, Ravindranath; Kim, Namwon

    2017-02-01

    We demonstrate a facile single step laser treatment process to render a polydimethylsiloxane (PDMS) surface superhydrophobic. By synchronizing a pulsed nanosecond laser source with a motorized stage, superhydrophobic grid patterns were written on the surface of PDMS. Hierarchical micro and nanostructures were formed in the irradiated areas while non-irradiated areas were covered by nanostructures due to deposition of ablated particles. Arrays of droplets form spontaneously on the laser-patterned PDMS with superhydrophobic grid pattern when the PDMS sample is simply immersed in and withdrawn from water due to different wetting properties of the irradiated and non-irradiated areas. The effects of withdrawal speed and pitch size of superhydrophobic grid on the size of formed droplets were investigated experimentally. The droplet size increases initially with increasing the withdrawal speed and then does not change significantly beyond certain points. Moreover, larger droplets are formed by increasing the pitch size of the superhydrophobic grid. The droplet arrays formed on the laser-patterned PDMS with wettability contrast can be used potentially for patterning of particles, chemicals, and bio-molecules and also for cell screening applications.

  16. Recent advances in very large area avalanche photodiodes

    NASA Astrophysics Data System (ADS)

    Squillante, Michael R.; Christian, James; Entine, Gerald; Farrell, Richard; Karger, Arieh M.; McClish, Mickel; Myers, Richard; Shah, Kanai S.; Taylor, David; Vanderpuye, Kofi; Waer, Peter; Woodring, Mitchell

    2003-09-01

    The Avalanche Photodiode (APD) is a unique device that combines the advantages of solid state photodetectors with those of high gain devices such as photomultiplier tubes (PMTs). APDs have internal gain that provides a high signal-to-noise ratio. APDs have high quantum efficiency, are fast, compact, and rugged. These properties make them suitable detectors for important applications such as LADAR, detection and identification toxic chemicals and bio-warfare agents, LIDAR fluorescence detection, stand-off laser induced breakdown spectroscopy (LIBS), and nuclear detectors and imagers. Recently there have been significant technical breakthroughs in fabricating very large APDs, APD arrays, and position sensitive APD arrays (PSAPD). Signal gain of over 10,000 has been achieved, single element APDs have been fabricated with active area greater than 40 cm2, monolithic pixelated arrays with up to 28 x 28 elements have been fabricated, and position sensitive APDs have been developed and tested. Additionally, significant progress has been made in improving the fabrication process to provide better uniformity and high yield, permitting cost effective manufacturing of APDs for reduced cost.

  17. Design of sphingomonad-detecting probes for a DNA array, and its application to investigate the behavior, distribution, and source of Rhizospherous sphingomonas and other sphingomonads inhabiting an acid sulfate soil paddock in Kalimantan, Indonesia.

    PubMed

    Hashidoko, Yasuyuki; Kitagawa, Emiko; Iwahashi, Hitoshi; Purnomo, Erry; Hasegawa, Toshihiro; Tahara, Satoshi

    2007-02-01

    Throughout Central and South Kalimantan, Indonesia, strongly acidic soil (pH 2.1-3.7) is widely distributed, and the local acidic soil-tolerant plants, including local rice varieties, often possess sphingomonads in their rhizosphere and rhizoplane. To investigate the behavior of sphingomonads inhabiting the rhizosphere of such acid-tolerant plants, we designed 13 different DNA array probes (each of 72 mer) specific to a group of sphingomonads, using a hypervariable V6 region of the 16S rRNA gene. This DNA array system was used preliminarily for an analysis of microfloral dynamisms, particularly of sphingomonads, in acidic paddock ecosystems, and the results suggest that the acid-tolerant local rice shares rhizospherous sphingomonads with wild Juncus sp., a predominant weed that thrives in acidic paddocks during the off-season for rice farming. This tentative conclusion supports the bio-rationality of the traditional rice farming system with respect to functional rhizobacteria.

  18. Diagnostic Performance of a Multiplex PCR assay for meningitis in an HIV-infected population in Uganda

    PubMed Central

    Rhein, Joshua; Bahr, Nathan C; Hemmert, Andrew C; Cloud, Joann L; Bellamkonda, Satya; Oswald, Cody; Lo, Eric; Nabeta, Henry; Kiggundu, Reuben; Akampurira, Andrew; Musubire, Abdu; Williams, Darlisha; Meya, David B; Boulware, David R

    2015-01-01

    Meningitis remains a worldwide problem, and rapid diagnosis is essential to optimize survival. We evaluated the utility of a multiplex PCR test in differentiating possible etiologies of meningitis. Cerebrospinal fluid (CSF) from 69 HIV-infected Ugandan adults with meningitis was collected at diagnosis (n=51) and among persons with cryptococcal meningitis during therapeutic lumbar punctures (n=68). Cryopreserved CSF specimens were analyzed with BioFire FilmArray® Meningitis/Encephalitis panel, which targets 17 pathogens. The panel detected Cryptococcus in the CSF of patients diagnosed with a first-episode of cryptococcal meningitis by fungal culture with 100% sensitivity and specificity, and differentiated between fungal relapse and paradoxical immune reconstitution inflammatory syndrome in recurrent episodes. A negative FilmArray result was predictive of CSF sterility on follow-up lumbar punctures for cryptococcal meningitis. EBV was frequently detected in this immunosuppressed population (n=45). Other pathogens detected included: CMV (n=2), VZV (n=2), HHV-6 (n=1), and Streptococcus pneumoniae (n=1). The FilmArray Meningitis/Encephalitis panel offers a promising platform for rapid meningitis diagnosis. PMID:26711635

  19. Simultaneous assessment of iodine, iron, vitamin A, malarial antigenemia, and inflammation status biomarkers via a multiplex immunoassay method on a population of pregnant women from Niger.

    PubMed

    Brindle, Eleanor; Lillis, Lorraine; Barney, Rebecca; Hess, Sonja Y; Wessells, K Ryan; Ouédraogo, Césaire T; Stinca, Sara; Kalnoky, Michael; Peck, Roger; Tyler, Abby; Lyman, Christopher; Boyle, David S

    2017-01-01

    Deficiencies of vitamin A, iron, and iodine are major public health concerns in many low- and middle-income countries, but information on their status in populations is often lacking due to high costs and logistical challenges associated with assessing micronutrient status. Accurate, user-friendly, and low-cost analytical tools are needed to allow large-scale population surveys on micronutrient status. We present the expansion of a 7-plex protein microarray tool for the simultaneous measurement of up to seven biomarkers with relevance to the assessment of the key micronutrients iron, iodine, and vitamin A, and inflammation and malaria biomarkers: α-1-acid glycoprotein, C-reactive protein, ferritin, retinol binding protein 4, soluble transferrin receptor, thyroglobulin, and histidine-rich protein II. Assay performance was assessed using international reference standards and then verified by comparing the multiplexed and conventional immunoassay results on a training panel of plasma samples collected from US adults. These data were used to assign nominal concentrations to the calibrators of the assay to further improve performance which was then assessed by interrogating plasma samples from a cohort of pregnant women from Niger. The correlation between assays for each biomarker measured from this cohort was typically good, with the exception of thyroglobulin, and the sensitivity ranged from 74% to 93%, and specificity from 81% to 98%. The 7-Plex micronutrient assay has the potential for use as an affordable tool for population surveillance of vitamin A, iron, and iodine deficiencies as well as falciparum malarial parasitemia infectivity and inflammation. The assay is easy-to-use, requires minimal sample volume, and is scalable, rapid, and accurate-needing only a low-cost reader and basic equipment present in most reference laboratory settings and so may be employed by low and middle income countries for micronutrient surveillance to inform on status in key populations. Micronutrient deficiencies including iron, iodine, and vitamin A affect a significant portion of the world's population. Efforts to assess the prevalence of these deficiencies in vulnerable populations are challenging, partly due to measurement tools that are inadequate for assessing multiple micronutrients in large-scale population surveys. We have developed a 7-plex immunoassay for the simultaneous measurement of seven biomarkers relevant to assessing iodine, iron, and vitamin A status, inflammation and Plasmodium falciparum parasitemia by measuring levels of thyroglobulin, ferritin, soluble transferrin receptor, retinol binding protein 4, α-1-acid glycoprotein, C-reactive protein, and histidine-rich protein II. This 7-plex immunoassay technique has potential as a rapid and effective tool for use in large-scale surveys and assessments of nutrition intervention programs in low- and middle-income countries.

  20. A Review on Development and Applications of Bio-Inspired Superhydrophobic Textiles

    PubMed Central

    Ahmad, Ishaq; Kan, Chi-wai

    2016-01-01

    Bio-inspired engineering has been envisioned in a wide array of applications. All living bodies on Earth, including animals and plants, have well organized functional systems developed by nature. These naturally designed functional systems inspire scientists and engineers worldwide to mimic the system for practical applications by human beings. Researchers in the academic world and industries have been trying, for hundreds of years, to demonstrate how these natural phenomena could be translated into the real world to save lives, money and time. One of the most fascinating natural phenomena is the resistance of living bodies to contamination by dust and other pollutants, thus termed as self-cleaning phenomenon. This phenomenon has been observed in many plants, animals and insects and is termed as the Lotus Effect. With advancement in research and technology, attention has been given to the exploration of the underlying mechanisms of water repellency and self-cleaning. As a result, various concepts have been developed including Young’s equation, and Wenzel and Cassie–Baxter theories. The more we unravel this process, the more we get access to its implications and applications. A similar pursuit is emphasized in this review to explain the fundamental principles, mechanisms, past experimental approaches and ongoing research in the development of bio-inspired superhydrophobic textiles. PMID:28774012

Top