Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, Tushar Kanti
2014-01-01
Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends. PMID:27006932
Anisotropic bioelectrical impedance determination of subcutaneous fat thickness
NASA Astrophysics Data System (ADS)
Hernández-Becerra, P. A. I.; Delgadillo-Holtfort, I.; Balleza-Ordaz, M.; Huerta-Franco, M. R.; Vargas-Luna, M.
2014-11-01
Preliminary results have shown that bioelectrical impedance measurements performed on different parts of the human body strongly depend upon the subcutaneous fat of the considered region. In this work, a method for the determination of subcutaneous fat thickness is explored. Within this method the measurement of the bioelectrical impedance response of the fat-muscle system, both along the direction defined by the muscle fibers and along the corresponding perpendicular direction, are performed. Measurements have been carried out on human female and male subjects of ages around 25 years old at the region of the biceps. Correlation has been performed with skinfold caliper measurements.
Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis
Weyer, Sören; Pauly, Karolin; Napp, Andreas; Dreher, Michael; Leonhardt, Steffen; Marx, Nikolaus; Schauerte, Patrick; Mischke, Karl
2015-01-01
Background. Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. Methods. 45 participants (21 with pleural effusion and 24 healthy subjects) were included. Bioelectrical impedance was analyzed for “Transthoracic,” “Foot to Foot,” “Foot to Hand,” and “Hand to Hand” vectors in low and high frequency domain before and after thoracentesis. Healthy subjects were measured at a single time point. Results. The mean volume of removed pleural effusion was 1169 ± 513 mL. The “Foot to Foot,” “Hand to Hand,” and “Foot to Hand” vector indicated a trend for increased bioelectrical impedance after thoracentesis. Values for the low frequency domain in the “Transthoracic” vector increased significantly (P < 0.001). A moderate correlation was observed between the amount of removed fluid and impedance change in the low frequency domain using the “Foot to Hand” vector (r = −0.7). Conclusion. Bioelectrical impedance changes in correlation with the thoracic fluid level. It was feasible to monitor significant fluid shifts and loss after thoracentesis in the “Transthoracic” vector by means of bioelectrical impedance spectroscopy. The trial is registered with Registration Numbers IRB EK206/11 and NCT01778270. PMID:25861647
Bioelectrical Impedance and Body Composition Assessment
ERIC Educational Resources Information Center
Martino, Mike
2006-01-01
This article discusses field tests that can be used in physical education programs. The most common field tests are anthropometric measurements, which include body mass index (BMI), girth measurements, and skinfold testing. Another field test that is gaining popularity is bioelectrical impedance analysis (BIA). Each method has particular strengths…
A Comparison of Three Methods to Measure Percent Body Fat on Mentally Retarded Adults.
ERIC Educational Resources Information Center
Burkett, Lee N.; And Others
1994-01-01
Reports a study that compared three measures for determining percent body fat in mentally retarded adults (multiple skinfolds and circumference measurements, Infrared Interactance, and Bioelectrical Impedance). Results indicated the Bioelectrical Impedance Analyzer and Infrared Interactance Analyzer produced values for percent body fat that were…
Whole-body impedance--what does it measure?
Foster, K R; Lukaski, H C
1996-09-01
Although the bioelectrical impedance technique is widely used in human nutrition and clinical research, an integrated summary of the biophysical and bioelectrical bases of this approach is lacking. We summarize the pertinent electrical phenomena relevant to the application of the impedance technique in vivo and discuss the relations between electrical measurements and biological conductor volumes. Key terms in the derivation of bioelectrical impedance analysis are described and the relation between the electrical properties of tissues and tissue structure is discussed. The relation between the impedance of an object and its geometry, scale, and intrinsic electrical properties is also discussed. Correlations between whole-body impedance measurements and various bioconductor volumes, such as total body water and fat-free mass, are experimentally well established; however, the reason for the success of the impedence technique is much less clear. The bioengineering basis for the technique is critically presented and considerations are proposed that might help to clarify the method and potentially improve its sensitivity.
ERIC Educational Resources Information Center
Rutherford, W. J.; Diemer, Gary A.; Scott, Eric D.
2011-01-01
Bioelectrical impedance analysis (BIA) is a widely used method for estimating body composition, yet issues concerning its validity persist in the literature. The purpose of this study was to validate percentage of body fat (BF) values estimated from BIA and skinfold (SF) with those obtained from hydrodensitometry (HD). Percent BF values measured…
Smart Multi-Frequency Bioelectrical Impedance Spectrometer for BIA and BIVA Applications.
Harder, Rene; Diedrich, Andre; Whitfield, Jonathan S; Buchowski, Macie S; Pietsch, John B; Baudenbacher, Franz J
2016-08-01
Bioelectrical impedance analysis (BIA) is a noninvasive and commonly used method for the assessment of body composition including body water. We designed a small, portable and wireless multi-frequency impedance spectrometer based on the 12 bit impedance network analyzer AD5933 and a precision wide-band constant current source for tetrapolar whole body impedance measurements. The impedance spectrometer communicates via Bluetooth with mobile devices (smart phone or tablet computer) that provide user interface for patient management and data visualization. The export of patient measurement results into a clinical research database facilitates the aggregation of bioelectrical impedance analysis and biolectrical impedance vector analysis (BIVA) data across multiple subjects and/or studies. The performance of the spectrometer was evaluated using a passive tissue equivalent circuit model as well as a comparison of body composition changes assessed with bioelectrical impedance and dual-energy X-ray absorptiometry (DXA) in healthy volunteers. Our results show an absolute error of 1% for resistance and 5% for reactance measurements in the frequency range of 3 kHz to 150 kHz. A linear regression of BIA and DXA fat mass estimations showed a strong correlation (r(2)=0.985) between measures with a maximum absolute error of 6.5%. The simplicity of BIA measurements, a cost effective design and the simple visual representation of impedance data enables patients to compare and determine body composition during the time course of a specific treatment plan in a clinical or home environment.
ERIC Educational Resources Information Center
Andreacci, Joseph L.; Nagle, Trisha; Fitzgerald, Elise; Rawson, Eric S.; Dixon, Curt B.
2013-01-01
Purpose: We examined the impact that cycle ergometry exercise had on percent body fat (%BF) estimates when assessed using either leg-to-leg or segmental bioelectrical impedance analysis (LBIA; SBIA) and whether the intensity of the exercise bout impacts the %BF magnitude of change. Method: Seventy-four college-aged adults participated in this…
ERIC Educational Resources Information Center
Andreacci, Joseph L.; Dixon, Curt B.; Rompolski, Krista; VanGorden, Kelly M.
2008-01-01
Bioelectrical impedance analysis (BIA) is a fast, easy to administer, and relatively inexpensive method of evaluating body composition. Due to the ease of operation, interest in using BIA to estimate percentage of body fat (%BF) has grown, especially in settings where body composition assessments are often performed without the benefit of…
Zhang, Hai-Long; Fu, Qiang; Li, Wen-Hui; Liu, Su-Wei; Zhong, Hua; Duoji, Bai-Ma; Zhang, Mei-Zhi; Lv, Po; Xi, Huan-Jiu
2015-01-01
We aimed to obtain the fat base value and the fat distribution characteristics of Tibetan children and teenagers by estimating their body fat content with the bioelectrical impedance method. We recruited 1427 healthy children and teenagers by a stratified cluster sampling method. By using bioelectrical impedance analysis, we obtained various values relevant to fat. We found that total body fat mass and the fat mass of various body parts increased with age in boys and girls. Yet there were no differences between age groups until 11 years. However, fat mass increased quickly between 11 and 18 years, and significant differences were seen between adolescent boys and girls; all fat indices were higher in girls than in boys (p<0.05). The characteristics of fat in Tibetan children and teenagers in Tibet is related to age and gender related hormone secretion, which reflects the physiological characteristics in different developmental stages.
NASA Astrophysics Data System (ADS)
Sharp, Andy; Heath, Jennifer; Peterson, Janet
2008-05-01
Consumer grade bioelectric impedance analysis (BIA) instruments measure the body's impedance at 50 kHz, and yield a quick estimate of percent body fat. The frequency dependence of the impedance gives more information about the current pathway and the response of different tissues. This study explores the impedance response of human tissue at a range of frequencies from 0.2 - 102 kHz using a four probe method and probe locations standard for segmental BIA research of the arm. The data at 50 kHz, for a 21 year old healthy Caucasian male (resistance of 180φ±10 and reactance of 33φ±2) is in agreement with previously reported values [1]. The frequency dependence is not consistent with simple circuit models commonly used in evaluating BIA data, and repeatability of measurements is problematic. This research will contribute to a better understanding of the inherent difficulties in estimating body fat using consumer grade BIA devices. [1] Chumlea, William C., Richard N. Baumgartner, and Alex F. Roche. ``Specific resistivity used to estimate fat-free mass from segmental body measures of bioelectrical impedance.'' Am J Clin Nutr 48 (1998): 7-15.
Ida, Midori; Hirata, Masakazu; Hosoda, Kiminori; Nakao, Kazuwa
2013-02-01
Two novel bioelectrical impedance analysis (BIA) methods have been developed recently for evaluation of intra-abdominal fat accumulation. Both methods use electrodes that are placed on abdominal wall and allow evaluation of intra-abdominal fat area (IAFA) easily without radiation exposure. Of these, "abdominal BIA" method measures impedance distribution along abdominal anterior-posterior axis, and IAFA by BIA method(BIA-IAFA) is calculated from waist circumference and the voltage occurring at the flank. Dual BIA method measures impedance of trunk and body surface at the abdominal level and calculates BIA-IAFA from transverse and antero-posterior diameters of the abdomen and the impedance of trunk and abdominal surface. BIA-IAFA by these two BIA methods correlated well with IAFA measured by abdominal CT (CT-IAFA) with correlatipn coefficient of 0.88 (n = 91, p < 0.0001) for the former, and 0.861 (n = 469, p < 0.01) for the latter. These new BIA methods are useful for evaluating abdominal adiposity in clinical study and routine clinical practice of metabolic syndrome and obesity.
Cheng, M-F; Chen, Y-Y; Jang, T-R; Lin, W-L; Chen, J; Hsieh, K-C
2016-12-01
Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject's total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA 8 , Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA 8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht 2 /Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA 8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA 8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA 8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers.
Cheng, M-F; Chen, Y-Y; Jang, T-R; Lin, W-L; Chen, J
2015-01-01
Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject’s total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA8, Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht2/Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers. PMID:28090145
Nwosu, Amara Callistus; Mayland, Catriona R; Mason, Stephen R; Khodabukus, Andrew F; Varro, Andrea; Ellershaw, John E
2013-09-01
Decisions surrounding the administration of clinically assisted hydration to patients dying of cancer can be challenging because of the limited understanding of hydration in advanced cancer and a lack of evidence to guide health care professionals. Bioelectrical impedance analysis (BIA) has been used to assess hydration in various patient groupings, but evidence for its use in advanced cancer is limited. To critically appraise existing methods of hydration status assessment in advanced cancer and review the potential for BIA to assess hydration in advanced cancer. Searches were carried out in four electronic databases. A hand search of selected peer-reviewed journals and conference abstracts also was conducted. Studies reporting (de)hydration assessment (physical examination, biochemical measures, symptom assessment, and BIA) in patients with advanced cancer were included. The results highlight how clinical examination and biochemical tests are standard methods of assessing hydration, but limitations exist with these methods in advanced cancer. Furthermore, there is disagreement over the evidence for some commonly associated symptoms with dehydration in cancer. Although there are limitations with using BIA alone to assess hydration in advanced cancer, analysis of BIA raw measurements through the method of bioelectrical impedance vector analysis may have a role in this population. The benefits and burdens of providing clinically assisted hydration to patients dying of cancer are unclear. Bioelectrical impedance vector analysis shows promise as a hydration assessment tool but requires further study in advanced cancer. Innovative methodologies for research are required to add to the evidence base and ultimately improve the care for the dying. Copyright © 2013 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
Macias, Nayeli; Alemán-Mateo, Heliodoro; Esparza-Romero, Julián; Valencia, Mauro E
2007-01-01
Background The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP) as standard method to measure body composition in Mexican adult men and women. Methods This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg) and height (Ht, cm) were obtained by standard anthropometric techniques. Resistance, R (ohms) and reactance, Xc (ohms) were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM). Results and Discussion The final model was: FFM (kg) = 0.7374 * (Ht2 /R) + 0.1763 * (BW) - 0.1773 * (Age) + 0.1198 * (Xc) - 2.4658. R2 was 0.97; the square root of the mean square error (SRMSE) was 1.99 kg, and the pure error (PE) was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg) and that measured by ADP (48.43 ± 11.3 kg). The new equation did not differ from the line of identity, had a high R2 and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg). Conclusion The new bioelectrical impedance equation based on the two-compartment model (2C) was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample. PMID:17697388
Aandstad, Anders; Holtberget, Kristian; Hageberg, Rune; Holme, Ingar; Anderssen, Sigmund A
2014-02-01
Previous studies show that body composition is related to injury risk and physical performance in soldiers. Thus, valid methods for measuring body composition in military personnel are needed. The frequently used body mass index method is not a valid measure of body composition in soldiers, but reliability and validity of alternative field methods are less investigated in military personnel. Thus, we carried out test and retest of skinfold (SKF), single frequency bioelectrical impedance analysis (SF-BIA), and multifrequency bioelectrical impedance analysis measurements in 65 male and female soldiers. Several validated equations were used to predict percent body fat from these methods. Dual-energy X-ray absorptiometry was also measured, and acted as the criterion method. Results showed that SF-BIA was the most reliable method in both genders. In women, SF-BIA was also the most valid method, whereas SKF or a combination of SKF and SF-BIA produced the highest validity in men. Reliability and validity varied substantially among the equations examined. The best methods and equations produced test-retest 95% limits of agreement below ±1% points, whereas the corresponding validity figures were ±3.5% points. Each investigator and practitioner must consider whether such measurement errors are acceptable for its specific use. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
Effect of Influenza-Induced Fever on Human Bioimpedance Values
Marini, Elisabetta; Buffa, Roberto; Contreras, Monica; Magris, Magda; Hidalgo, Glida; Sanchez, Wilmer; Ortiz, Vanessa; Urbaez, Maryluz; Cabras, Stefano; Blaser, Martin J.; Dominguez-Bello, Maria G.
2015-01-01
Background and Aims Bioelectrical impedance analysis (BIA) is a widely used technique to assess body composition and nutritional status. While bioelectrical values are affected by diverse variables, there has been little research on validation of BIA in acute illness, especially to understand prognostic significance. Here we report the use of BIA in acute febrile states induced by influenza. Methods Bioimpedance studies were conducted during an H1N1 influenza A outbreak in Venezuelan Amerindian villages from the Amazonas. Measurements were performed on 52 subjects between 1 and 40 years of age, and 7 children were re-examined after starting Oseltamivir treatment. Bioelectrical Impedance Vector Analysis (BIVA) and permutation tests were applied. Results For the entire sample, febrile individuals showed a tendency toward greater reactance (p=0.058) and phase angle (p=0.037) than afebrile individuals, while resistance and impedance were similar in the two groups. Individuals with repeated measurements showed significant differences in bioimpedance values associated with fever, including increased reactance (p<0.001) and phase angle (p=0.007), and decreased resistance (p=0.007) and impedance (p<0.001). Conclusions There are bioelectrical variations induced by influenza that can be related to dehydration, with lower extracellular to intracellular water ratio in febrile individuals, or a direct thermal effect. Caution is recommended when interpreting bioimpedance results in febrile states. PMID:25915945
NASA Astrophysics Data System (ADS)
Kanti Bera, Tushar
2018-03-01
Biological tissues are developed with biological cells which exhibit complex electrical impedance called electrical bioimpedance. Under an alternating electrical excitation the bioimpedance varies with the tissue anatomy, composition and the signal frequency. The current penetration and conduction paths vary with frequency of the applied signal. Bioimpedance spectroscopy is used to study the frequency response of the electrical impedance of biological materials noninvasively. In bioimpedance spectroscopy, a low amplitude electrical signal is injected to the tissue sample or body parts to characterization the sample in terms of its bioimpedance. The electrical current conduction phenomena, which is highly influenced by the tissue impedance and the signal frequency, is an important phenomena which should be studied to understand the bioimpedance techniques like bioelectrical impedance analysis (BIA), EIS, or else. In this paper the origin of bioelectrical impedance and current conduction phenomena has been reviewed to present a brief summary of bioelectrical impedance and the frequency dependent current conduction through biological tissues. Simulation studies are conducted with alternation current injection through a two dimensional model of biological tissues containing finite number of biological cells suspended in extracellular fluid. The paper demonstrates the simulation of alternating current conduction through biological tissues conducted by COMSOL Multiphysics. Simulation studies also show the frequency response of the tissue impedance for different tissue compositions.
Galluzzo, M; Talamonti, M; Perino, F; Servoli, S; Giordano, D; Chimenti, S; De Simone, C; Peris, K
2017-06-01
There is strong evidence that obesity is closely associated with psoriasis. However, data on body composition are lacking in psoriasis. The purpose of this study were to investigate the body composition in psoriasis patients using bioelectrical impedance analysis and to correlate the bioelectrical impedance data with disease severity and laboratory parameters. Anthropometric measurements and bioelectrical impedance analyses were performed on patients with psoriasis, naïve to any systemic treatment, who attended the outpatient clinics of two University centers. Data of 164 adult patients were analyzed. Compared to men, women had several significantly higher bioelectrical impedance parameters including reactance, fat mass% and adipose tissue%. The values of adipose tissue were positively correlated only with patients age (p = .021) and age at disease onset (p = .0006), but not with disease severity. In addition, we observed that the use of BMI cutoffs allowed to categorize 36.7% of women and 19.2% of men as obese, while fat mass% showed that 53.3% of women and 48.1% of men were obese. In our study, psoriasis is been associated with a high fat mass%. We suggest that screening for body fat distribution in psoriatic patients might be useful to identify early obesity-related disease.
Kirkendall, D T; Grogan, J W; Bowers, R G
1991-01-01
Body composition and appropriate playing weight are frequently requested by coaches. Numerous methods for estimating these figures are available, and each has its own limitation, be it technical or biological. A comparison of three common methods was made-underwater weighting (H2O, the criterion), skinfold thicknesses (SF), and commercial bioelectrical impedance analysis (BIA). Subjects were 29 professional football players measured by each of the three methods after an overnight fast. Data was collected 10 weeks preceding the players' formal training camp. There was no difference for percentage of weight as fat between SF (15.8%) and H2O (14.2%). Bioelectrical impedance analysis significantly (p < .05) overestimated percent fat (19.2%) compared to H20. Error rates when regressing SF on H2O were favorable, whether expressed for the whole sample (3.04%) or by race (1.78% or 3.56% for whites and blacks, respectively). Regression of BIA on H2O showed an elevated, overall error rate (14.12%) and elevated error rates for whites (11.57%) and blacks (13.81%). Of the two estimates of body composition on a racially mixed sample of males, SF provided the best estimate with the least amount of error. J Orthop Sports Phys Ther 1991;13(5):235-239.
de Freitas Junior, Wilson Rodrigues; Ilias, Elias Jirjoss; Kassab, Paulo; Cordts, Roberto; Porto, Paulo Gustavo; Martins Rodrigues, Francisco Cesar; Ali Taha, Mohamed Ibrahim; Carrara, Paulo; de Carvalho Aguiar, Isabella; de Oliveira, Luis Vicente Franco; Malheiros, Carlos Alberto
2014-01-01
Background. Bariatric surgery is considered an effective option for the management of morbid obesity. The incidence of obesity has been gradually increasing all over the world reaching epidemic proportions in some regions of the world. Obesity can cause a reduction of up to 22% in the life expectancy of morbidly obese patients. Objective. The objective of this paper is to assess the weight loss associated with the first 6 months after bariatric surgery using bioelectric impedance analysis (BIA) for the evaluation of fat mass and fat-free mass. Method. A total of 36 morbidly obese patients were subjected to open gastric bypass surgery. The patients weight was monitored before and after the procedure using the bioelectric impedance analysis. Results. Bariatric surgery resulted in an average percentage of weight loss of 28.6% (40 kg) as determined 6 months after the procedure was performed. Analysis of the different components of body weight indicated an undesirable loss of fat-free mass along with the reduction of total body weight. Conclusion. Open gastric bypass induced a significant loss of total weight and loss of fat-free mass in patients six months after the surgery. The use of bioelectric impedance analysis resulted in an appropriate estimation of the total weight components in individuals subjected to bariatric surgery allowing a more real analysis of the variation of weight after the surgery. PMID:24523649
BIOELECTRICAL IMPEDANCE VECTOR ANALYSIS IDENTIFIES SARCOPENIA IN NURSING HOME RESIDENTS
USDA-ARS?s Scientific Manuscript database
Loss of muscle mass and water shifts between body compartments are contributing factors to frailty in the elderly. The body composition changes are especially pronounced in institutionalized elderly. We investigated the ability of single-frequency bioelectrical impedance analysis (BIA) to identify b...
Estimating body fat by using bioelectrical-impedance measurements: a preliminary assessment.
M.G. Raphael; H.J. Harlow; S.W. Buskirk
1991-01-01
We evaluated a technique for measuring body fat content of marten (Martes americana) by using a noninvasive bioelectrical-impedance device with four electrodes to introduce a current into the body. Instantaneous readings of resistance were significantly correlated with fat-free mass (determined from solvent extraction) of carcasses of 17 skinned (r...
Oppliger, R A; Nielsen, D H; Shetler, A C; Crowley, E T; Albright, J P
1992-01-01
The need for simple, valid techniques of body composition assessment among athletes is a growing concern of the physical therapist. This paper reports on several common methods applied to university football players. Body composition analysis was conducted on 28 Division IA football players using three different bioelectrical impedance analysis (BIA) systems, skinfolds (SF), and hydrostatic weighing (HYDRO). Correlations for all methods with HYDRO were high (>.88), but BIA significantly overpredicted body fatness. In contrast, three SF equations showed small differences with HYDRO and reasonable measurement error. Clinicians should exercise caution when using BIA based on the existing manufacturers' equations with athletic populations. Adjustments to BIA regression equations by including modifying or anthropometric variables could enhance the predictive accuracy of these methods with lean, athletic males. J Orthop Sports Phys Ther 1992;15(4):187-192.
Franco-Villoria, Maria; Wright, Charlotte M; McColl, John H; Sherriff, Andrea; Pearce, Mark S
2016-01-01
Objectives To explore the usefulness of Bioelectrical Impedance Analysis (BIA) for general use by identifying best-evidenced formulae to calculate lean and fat mass, comparing these to historical gold standard data and comparing these results with machine-generated output. In addition, we explored how to best to adjust lean and fat estimates for height and how these overlapped with body mass index (BMI). Design Cross-sectional observational study within population representative cohort study. Setting Urban community, North East England Participants Sample of 506 mothers of children aged 7–8 years, mean age 36.3 years. Methods Participants were measured at a home visit using a portable height measure and leg-to-leg BIA machine (Tanita TBF-300MA). Measures Height, weight, bioelectrical impedance (BIA). Outcome measures Lean and fat mass calculated using best-evidenced published formulae as well as machine-calculated lean and fat mass data. Results Estimates of lean mass were similar to historical results using gold standard methods. When compared with the machine-generated values, there were wide limits of agreement for fat mass and a large relative bias for lean that varied with size. Lean and fat residuals adjusted for height differed little from indices of lean (or fat)/height2. Of 112 women with BMI >30 kg/m2, 100 (91%) also had high fat, but of the 16 with low BMI (<19 kg/m2) only 5 (31%) also had low fat. Conclusions Lean and fat mass calculated from BIA using published formulae produces plausible values and demonstrate good concordance between high BMI and high fat, but these differ substantially from the machine-generated values. Bioelectrical impedance can supply a robust and useful field measure of body composition, so long as the machine-generated output is not used. PMID:26743700
Prediction of beef carcass salable yield and trimmable fat using bioelectrical impedance analysis.
Zollinger, B L; Farrow, R L; Lawrence, T E; Latman, N S
2010-03-01
Bioelectrical impedance technology (BIA) is capable of providing an objective method of beef carcass yield estimation with the rapidity of yield grading. Electrical resistance (Rs), reactance (Xc), impedance (I), hot carcass weight (HCW), fat thickness between the 12th and 13th ribs (FT), estimated percentage kidney, pelvic, and heart fat (KPH%), longissimus muscle area (LMA), length between electrodes (LGE) as well as three derived carcass values that included electrical volume (EVOL), reactive density (XcD), and resistive density (RsD) were determined for the carcasses of 41 commercially fed cattle. Carcasses were subsequently fabricated into salable beef products reflective of industry standards. Equations were developed to predict percentage salable carcass yield (SY%) and percentage trimmable fat (FT%). Resulting equations accounted for 81% and 84% of variation in SY% and FT%, respectively. These results indicate that BIA technology is an accurate predictor of beef carcass composition. Copyright 2009 Elsevier Ltd. All rights reserved.
Escobar-Cardozo, Germán D; Correa-Bautista, Jorge E; González-Jiménez, Emilio; Schmidt-RioValle, Jacqueline; Ramírez-Vélez, Robinson
2016-04-01
The analysis of body composition is a fundamental part of nutritional status assessment. The objective of this study was to establish body fat percentiles by bioelectrical impedance in children and adolescents from Bogotá (Colombia) who were part of the FUPRECOL study (Asociación de la Fuerza Prensil con Manifestaciones Tempranas de Riesgo Cardiovascular en Niños y Adolescentes Colombianos - Association between prehensile force and early signs of cardiovascular risk in Colombian children and adolescents). This was a cross-sectional study conducted among 5850 students aged 9-17.9 years old from Bogotá (Colombia). Body fat percentage was measured using foot-to-foot bioelectrical impedance (Tanita®, BF-689), by age and gender. Weight, height, waist circumference, and hip circumference were measured, and sexual maturity was self-staged. Percentiles (P3, P10, P25, P50, P75, P90 and P97) and centile curves were estimated using the LMS method (L [BoxCox curve], M [median curve] and S [variation coefficient curve]), by age and gender. Subjects included were 2526 children and 3324 adolescents. Body fat percentages and centile curves by age and gender were established. For most age groups, values resulted higher among girls than boys. Participants with values above P90 were considered to have a high cardiovascular risk due to excess fat (boys > 23.428.3, girls > 31.0-34.1). Body fat percentage percentiles measured using bioelectrical impedance by age and gender are presented here and may be used as reference to assess nutritional status and to predict cardiovascular risk due to excess fat at an early age. Sociedad Argentina de Pediatría.
Carrasco-Marginet, Marta; Castizo-Olier, Jorge; Rodríguez-Zamora, Lara; Iglesias, Xavier; Rodríguez, Ferran A.; Chaverri, Diego; Brotons, Daniel
2017-01-01
Purpose The assessment of body hydration is a complex process, and no measurement is valid for all situations. Bioelectrical impedance vector analysis (BIVA) has emerged as a relatively novel technique for assessing hydration status in sports. We applied BIVA a) to determine hydration changes evoked by an intense synchronized swimming (SS) training session; b) to characterize the sample of young elite swimmers in relation with a nonathletic reference population; and c) to generate its 50%, 75% and 95% percentiles of the bioelectrical variables. Methods Forty-nine elite SS female swimmers of two age categories, comen (Co: 13.9 ± 0.9 years, n = 34) and junior (Jr: 16.3 ± 0.6 years, n = 15), performed a long, high intensity training session. Body mass (BM) and bioelectrical variables (R, resistance; Xc, reactance; PA, phase angle; and Z, impedance module) were assessed pre- and post-training. BIVA was used to characterize 1) the distribution pattern of the bioelectrical vector (BIA vector) for both age groups, and 2) pre- to post-training BIA vector migration. Bioelectrical variables were also correlated with BM change values. Results Most swimmers were mostly located outside the 75% and some beyond the 95% percentile of the bioelectrical tolerance ellipses of the general population. The BIA vector showed statistically significant differences in both Co (T2 = 134.7, p = 0.0001) and Jr (T2 = 126.2, p < 0.001). Both groups were also bioelectrically different (T2 = 17.6, p < 0.001). After the training session, a decrease in BM (p = 0.0001) and an increase in BIA variables (p = 0.01) was observed. BIVA also showed a significant pre-post vector migration both in Co (T2 = 82.1; p < 0.001) and Jr (T2 = 41.8; p < 0.001). No correlations were observed between BM changes and bioelectrical variables. Conclusions BIVA showed specific bioelectrical characteristics in young elite SS athletes. Considering the decrease in BM and the migration of the BIA vector, we conclude that the homeostatic hydration status of these young elite female swimmers was affected by the execution of intense training sessions. From a methodological perspective, BIVA appears to be sensitive enough to detect subtle hydration changes, but further research is needed to ensure its validity and reliability. Moreover, these findings highlight the importance of ensuring adequate fluid intake during training in young SS athletes. PMID:28591135
ERIC Educational Resources Information Center
Company, Joe; Ball, Stephen
2010-01-01
The primary purpose of this study was to investigate the accuracy of the DF50 (ImpediMed Ltd, Eight Mile Plains, Queensland, Australia) bioelectrical impedance analysis device using dual-energy x-ray absorptiometry as the criterion in two groups: endurance athletes and power athletes. The secondary purpose was to develop accurate body fat…
Visceral fat estimation method by bioelectrical impedance analysis and causal analysis
NASA Astrophysics Data System (ADS)
Nakajima, Hiroshi; Tasaki, Hiroshi; Tsuchiya, Naoki; Hamaguchi, Takehiro; Shiga, Toshikazu
2011-06-01
It has been clarified that abdominal visceral fat accumulation is closely associated to the lifestyle disease and metabolic syndrome. The gold standard in medical fields is visceral fat area measured by an X-ray computer tomography (CT) scan or magnetic resonance imaging. However, their measurements are high invasive and high cost; especially a CT scan causes X-ray exposure. They are the reasons why medical fields need an instrument for viscera fat measurement with low invasive, ease of use, and low cost. The article proposes a simple and practical method of visceral fat estimation by employing bioelectrical impedance analysis and causal analysis. In the method, abdominal shape and dual impedances of abdominal surface and body total are measured to estimate a visceral fat area based on the cause-effect structure. The structure is designed according to the nature of abdominal body composition to be fine-tuned by statistical analysis. The experiments were conducted to investigate the proposed model. 180 subjects were hired to be measured by both a CT scan and the proposed method. The acquired model explained the measurement principle well and the correlation coefficient is 0.88 with the CT scan measurements.
Validity of body composition assessment methods for older men with cardiac disease.
Young, H; Porcari, J; Terry, L; Brice, G
1998-01-01
This study was designed to determine which of several body composition assessment methods was most accurate for patients with cardiac disease for the purpose of outcome measurement. Six body composition assessment methods were administered to each of 24 men with cardiac disease. Methods included circumference measurement, skinfold measurement, near-infrared interactance via the Futrex-5000, bioelectrical impedance via the BioAnalogics ElectroLipoGraph and Tanita TBF-150, and hydrostatic weighing, the criterion measure. A repeated measures analysis of variance indicated no significant (P > .05) difference between circumference and skinfold measurements compared to hydrostatic weighing. Near-infrared interactance presented the best standard error of estimates (3.5%) and the best correlation (r = .84) with hydrostatic weighing; however, the constant error was 3.76%. Bioelectrical impedance measured by the ElectroLipoGraph and TBF-150 instruments significantly underestimated percent body fat by 8.81% and 4.8%, respectively. In this study of middle-aged to older men with cardiac disease, the best method for determining body fat was circumferences. This technique was accurate, easy to administer, inexpensive, and had a lower error potential than the other techniques. Skinfold measurements were also closely related to hydrostatic weighing, but should be performed only by experienced practitioners because there is a greater potential for tester error in certain patients. In the future, near-infrared interactance measurements may be a viable technique for body composition assessment in patients with cardiac disease. However, algorithms specific to the population of patients with cardiac disease being tested must be developed before this technique can be routinely recommended for body composition assessment. Bioelectrical impedance assessment by either method is not recommended for patients with cardiac disease, as it consistently underestimated percent body fat when compared to hydrostatic weighing in this population.
Ayas, Selçuk; Bayraktar, Mesut; Gürbüz, Ayşe; Alkan, Akif; Eren, Sadiye
2012-01-01
Objective: We aimed to evaluate uterine junctional zone thickness, cervical length and bioelectrical impedance analysis of body composition in women with endometriosis. Material and Methods: This is a prospective study conducted in a tertiary teaching hospital. A total of 73 patients were included in the study. Endometriosis was surgically diagnosed in 36 patients (study group). The control group included 37 patients. Main outcome measure(s): Bioelectrical impedance analysis was used to measure body composition. Uterine junctional zone thickness and cervical length were measured by transvaginal ultrasonography. Results: Patients’ characteristics (age, gravida, parity, live baby, age of menarche, lengths of menstrual cycle, percentage of patients with dysmenorrhea, positive family history), body mass index (BMI) (kg/m2), amount of body fat (kg), percentage of body fat were not statistically different between the two groups (p>0.05). The length of menstruation and cervical length were longer in women with endometriosis. Similarly, the inner myometrium was thicker in women with endometriosis than the control group. Conclusion: The relation between endometriosis and demographic features such as age, gravida, parity, gravida, BMI, lengths of the menstrual cycle, age of menarche are controversial. Longer cervical length and thicker inner myometrial layer may be important in the etiopathogenesis of endometriosis. PMID:25207044
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kushner, R.F.; Kunigk, A.; Alspaugh, M.
1990-08-01
The bioelectrical-impedance-analysis (BIA) method accurately measures body composition in weight-stable subjects. This study validates the use of BIA to measure change in body composition. Twelve obese females underwent weight loss at a mean rate of 1.16 kg/wk. Body composition was measured by deuterium oxide dilution (D2O), BIA, and skinfold anthropometry (SFA) at baseline and at 5% decrements in weight. Highly significant correlations were obtained between D2O and BIA (r = 0.971) and between D2O and SFA (r = 0.932). Overall, BIA predicted change in fat-free mass with greater accuracy (to 0.4 kg) and precision (+/- 1.28 kg) than did anthropometrymore » (to 0.8 kg and +/- 2.58 kg, respectively). We conclude that BIA is a useful clinical method for measuring change in body composition.« less
Ellis, K J; Bell, S J; Chertow, G M; Chumlea, W C; Knox, T A; Kotler, D P; Lukaski, H C; Schoeller, D A
1999-01-01
In 1994, the National Institutes of Health (NIH) convened a Technology Assessment Conference "to provide physicians with a responsible assessment of bioelectrical impedance analysis (BIA) technology for body composition measurement." In 1997, Serono Symposia USA, Inc., organized an invited panel of scientists and clinicians, with extensive research and clinical experience with BIA, to provide an update. Panel members presented reviews based on their own work and published studies for the intervening years. Updates were provided on the single and multifrequency BIA methods and models; continued clinical research experiences; efforts toward establishing population reference norms; and the feasibility of establishing guidelines for potential diagnostic use of BIA in a clinical setting. This report provides a summary of the panel's findings including a consensus on several technical and clinical issues related to the research use of BIA, and those areas that are still in need of additional study.
Berg, E P; Neary, M K; Forrest, J C; Thomas, D L; Kauffman, R G
1996-11-01
Market weight lambs, average weight 52.5 kg (+/-6.1), were used to evaluate nontraditional live animal measurements as predictors of carcass composition. The sample population (n = 106) represented U.S. market lambs and transcended geographic location, breed, carcass weight, yield grade, and production system. Realtime ultrasonic (RU) measurements and bioelectrical impedance analysis (BIA) were used for development and evaluation of prediction equations for % boneless, closely trimmed primal cuts (BCTPC), weight or % of dissected lean tissue (TDL), and chemically derived weight or % fat-free lean (FFL). Longitudinal ultrasonic images were obtained parallel to the longissimus thoracis et lumborum (LTL), positioning the last costae in the center of the transducer head. Images were saved and fat and LTL depths were derived from printed images of the ultrasonic scans. Bioelectrical impedance analysis was administered via a four-terminal impedance plethysmograph operating at 800 microA at 50 kHz. Impedance measurements of whole-body resistance and reactance were recorded. Prediction equations including common linear measurements of live weight, heart girth, hindsaddle length, and shoulder height were also evaluated. All measurements were taken just before slaughter. Bioelectrical impedance measurements (as compared to RU and linear measurements) provided equations for %BCTPC, TDL, %TDL, FFL and %FFL with the highest R2 and lowest root mean square error. Even though BIA provided the best equations of the three methodologies tested, prediction of proportional yield (%BCTPC, %TDL, and %FFL) was marginal (R2 = .296, .551, and .551, respectively). Equations combining BIA, RU, and linear measurements greatly improved equations for prediction of proportional lean yield.
Ward, L; Cornish, B H; Paton, N I; Thomas, B J
1999-11-01
It has been proposed that multiple frequency bioelectrical impedance models of the human body should include an inductive property for the circulatory system, the inductor circuit model (ICM), and that such a model, when coupled with a new method of data analysis, can improve the predictive power of multiple frequency bioelectrical impedance analysis (MFBIA). This hypothesis was tested using MFBIA measurements and gold standard measures of total body and extracellular water volumes in a cross-validation study in two subject groups (viz. controls and HIV). The MFBIA measurements were analysed using the current, widely accepted Cole model and the alternative ICM model which includes an inductive component. Correlations in the range 0.75 to 0.92 (for TBW) and 0.46 to 0.79 (for ECW) for impedance quotients versus gold standard measures within the subject groups were observed. These decreased, to as low as r = 0.50 for TBW and r = 0.29 for ECW, when the derived algorithms were applied to the alternative subject group. These results suggest that lack of portability of MFBIA algorithms between subject groups is not due to an inadequacy of the analogue circuit model per se but is possibly due more to fundamental flaws in the principles associated with its application. These include assuming a constant proportionality of body segment geometries and tissue fluid resistivities. This study has also demonstrated that this inadequacy cannot be overcome by simply introducing an inductive component into the analogue electrical circuit.
NASA Astrophysics Data System (ADS)
Kapica, Dominik; Warchulińska, Joanna; Jakubiak, Monika; Teter, Mariusz; Mlak, Radosław; Hałabiś, Magdalena; Wójcik, Waldemar; Małecka-Massalska, Teresa
2015-09-01
Introduction: Bioelectrical impedance analysis (BIA) is a useful tool to asses human body composition and nutrition status; multi-frequency BIA has a higher accuracy than single-frequency BIA. In our study a difference of impedance values (Z) at 5, 100 and 200 kHz and Z200/Z5 index between professional athletes and control group were determined. Methods: In this research 105 people were tested, divided into control group (72 people: 35 males and 37 females) and professional athletes (33 people: 16 males and 17 females). Impedance was measured at three frequency values - 5, 100 and 200 kHz; with received values the Z200/Z5 index was calculated. Results: In most compared subgroups impedance values showed significantly lower values in athletes than in control group (5 kHz - males: p=0.136, females: p=0.001, 100 kHz - males: p=0.039, females: p<0.0001, 200 kHz - males: p=0.047, females: p<0.0001) Z200/Z5 index also showed lower value in athletes than in control group (p=0.016 for males, p<0.0001 for females). Conclusion: Lower values of impedance and Z200/Z5 index indicates a better nutrition status and general health condition of athletes than in control group.
Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors
Khoury, Dirar S.; Naware, Mihir; Siou, Jeff; Blomqvist, Andreas; Mathuria, Nilesh S.; Wang, Jianwen; Shih, Hue-Teh; Nagueh, Sherif F.; Panescu, Dorin
2009-01-01
Objectives To investigate properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy (CRT) system. Background Monitoring of CHF has relied mainly on right-heart sensors. Methods Fifteen normal dogs underwent implantation of CRT systems using standard leads. An additional left atrial (LA) pressure lead-sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathorcaic and intracardiac vectors, were measured via ring (r), coil (c), and device Can electrodes. Results All animals developed CHF after 2–4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LVr-Can, −17%; LVr-RVr, −15%; LVr-RAr, −11%; RVr-Can, −12%; RVc-Can, −7%; RAr-Can, −5%. The LVr-Can vector reflected both the fastest and largest change in impedance in comparison to vectors employing only right-heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. Conclusions Impedance, acquired via different lead-electrodes, have variable responses to CHF. Impedance vectors employing a LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients. PMID:19298923
Effect of Intravenous Infusion Solutions on Bioelectrical Impedance Spectroscopy.
Yap, Jason; Rafii, Mahroukh; Azcue, Maria; Pencharz, Paul
2017-05-01
Bioelectrical impedance (BIA) is often used to measure body fluid spaces and thereby body composition. However, in acute animal studies, we found that impedance was driven by the saline content of intravenous (IV) fluids and not by the volume. The aim of the study was to investigate the effect of 3 different fluids acutely administered on the change in impedance, specifically resistance (R). Nine healthy adults participated in 3 treatment (0.9% saline, 5% dextrose, and a mixture of 0.3% saline + 3.3% dextrose) experiments on nonconsecutive days. They all received 1 L of one of the treatments intravenously over a 1-hour period. Repeated BIA measurements were performed prior to IV infusion and then every 5 minutes for the 1-hour infusion period, plus 3 more measurements up to 15 minutes after the completion of the infusion. The change in R in the 0.9% saline infusion experiment was significantly lower than that of the glucose and mixture treatment ( P < .001). Bioelectrical impedance spectroscopy and BIA measure salt rather than the volume changes over the infusion period. Hence, in patients receiving IV fluids, BIA of any kind (single frequency or multifrequency) cannot be used to measure body fluid spaces or body composition.
Franco-Villoria, Maria; Wright, Charlotte M; McColl, John H; Sherriff, Andrea; Pearce, Mark S
2016-01-07
To explore the usefulness of Bioelectrical Impedance Analysis (BIA) for general use by identifying best-evidenced formulae to calculate lean and fat mass, comparing these to historical gold standard data and comparing these results with machine-generated output. In addition, we explored how to best to adjust lean and fat estimates for height and how these overlapped with body mass index (BMI). Cross-sectional observational study within population representative cohort study. Urban community, North East England Sample of 506 mothers of children aged 7-8 years, mean age 36.3 years. Participants were measured at a home visit using a portable height measure and leg-to-leg BIA machine (Tanita TBF-300MA). Height, weight, bioelectrical impedance (BIA). Lean and fat mass calculated using best-evidenced published formulae as well as machine-calculated lean and fat mass data. Estimates of lean mass were similar to historical results using gold standard methods. When compared with the machine-generated values, there were wide limits of agreement for fat mass and a large relative bias for lean that varied with size. Lean and fat residuals adjusted for height differed little from indices of lean (or fat)/height(2). Of 112 women with BMI >30 kg/m(2), 100 (91%) also had high fat, but of the 16 with low BMI (<19 kg/m(2)) only 5 (31%) also had low fat. Lean and fat mass calculated from BIA using published formulae produces plausible values and demonstrate good concordance between high BMI and high fat, but these differ substantially from the machine-generated values. Bioelectrical impedance can supply a robust and useful field measure of body composition, so long as the machine-generated output is not used. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Lee, Simon; Bountziouka, Vassiliki; Lum, Sooky; Stocks, Janet; Bonner, Rachel; Naik, Mitesh; Fothergill, Helen; Wells, Jonathan C. K.
2014-01-01
Background Bioelectrical Impedance Analysis (BIA) has the potential to be used widely as a method of assessing body fatness and composition, both in clinical and community settings. BIA provides bioelectrical properties, such as whole-body impedance which ideally needs to be calibrated against a gold-standard method in order to provide accurate estimates of fat-free mass. UK studies in older children and adolescents have shown that, when used in multi-ethnic populations, calibration equations need to include ethnic-specific terms, but whether this holds true for younger children remains to be elucidated. The aims of this study were to examine ethnic differences in body size, proportions and composition in children aged 5 to 11 years, and to establish the extent to which such differences could influence BIA calibration. Methods In a multi-ethnic population of 2171 London primary school-children (47% boys; 34% White, 29% Black African/Caribbean, 25% South Asian, 12% Other) detailed anthropometric measurements were performed and ethnic differences in body size and proportion were assessed. Ethnic differences in fat-free mass, derived by deuterium dilution, were further evaluated in a subsample of the population (n = 698). Multiple linear regression models were used to calibrate BIA against deuterium dilution. Results In children <11 years of age, Black African/Caribbean children were significantly taller, heavier and had larger body size than children of other ethnicities. They also had larger waist and limb girths and relatively longer legs. Despite these differences, ethnic-specific terms did not contribute significantly to the BIA calibration equation (Fat-free mass = 1.12+0.71*(height2/impedance)+0.18*weight). Conclusion Although clear ethnic differences in body size, proportions and composition were evident in this population of young children aged 5 to 11 years, an ethnic-specific BIA calibration equation was not required. PMID:25478928
Shimizu, Miyuki; Kinoshita, Kensuke; Maeno, Takami; Kobayashi, Hiroyuki; Maeno, Tetsuhiro
2017-11-01
Dehydration in older patients has long been considered a significant health problem because it implies increased morbidity and mortality. However, dehydration is detected by a combination of physical signs and blood tests. For older people dwelling at home and in nursing homes, a simple and non-invasive method for detecting dehydration by caregivers is needed. The total body resistance is measured using bioelectrical impedance analysis and is known as an indicator of dehydration. There are no data from older Japanese patients on this issue. We performed this study to examine the relationship between dehydration and total body resistance in Japan. We performed blood tests and measured bioelectrical impedance in older outpatients aged ≥ 65 years from the Internal Medicine Department at Mito Kyodo General Hospital. Patients were classified as dehydrated and non-dehydrated using the dehydration index with a blood urea nitrogen/creatinine ratio > 20, and the mean total body resistance was compared between the two groups. Eighty-one patients were recruited in the study. In the dehydrated group, the mean total body resistance was 439 Ω at 50 kHz, which was significantly higher than that in the non-dehydrated group (408 Ω, P = 0.038). The total body resistance measurements can be used for simple assessment of dehydration among older Japanese patients.
[Sensitivity and specificity of abdominal adiposity with metabolic syndrome in the elderly].
Alvero-Cruz, José Ramón; Fernández Vázquez, Rosalía; García Vega, María Del Mar; García Lavigne, Juan Antonio; Rodríguez Linares, María Victoria; Martínez Blanco, Javier
It is recognised that abdominal adiposity is associated with cardiovascular risk factors, such as intolerance to glucose, hypertension and dyslipidaemia. The objective of the present study was to assess the relationship of trunk fat and visceral fat index, obtained by anthropometric and bioelectrical impedance, with metabolic syndrome (SM) in an elderly population. The study included 208 subjects (78 men and 130 women) with a mean age of 82.5 years. Abdominal obesity was assessed by anthropometry and bioelectrical impedance. ROC curves were calculated in order to assess the ability of these variables to diagnose metabolic syndrome. There are differences between men and women in body mass index, waist to height ratio, waist circumference, and bioelectrical impedance measurements as trunk fat and visceral fat (p<.05). Also, found differences in anthropometric indices and variables and abdominal bioelectrical impedance between subjects with and without SM (p<.05) and only exist differences in blood glucose, triglycerides and HDL cholesterol (p<.05). There are significant correlations between anthropometric variables and abdominal bioelectrical impedance (p<.05). Areas under the curve (AUC) of waist to height index, waist circumference, sagittal abdominal diameter, and trunk fat were greater than 0.8 (all p<.01), and in women did not exceed values of 0.65. The cut-off points obtained for BMI were 26.81 and 23.53kg/m 2 , 102 and 91cm for waist circumference, 22.1 and 20.7cm for sagittal abdominal diameter, 34% and 43.7% for trunk fat, and 17 and 11.5 for visceral fat ratio in men and women, respectively. There are different levels of predictive ability for metabolic syndrome according to gender. Trunk fat and visceral fat index and anthropometric measures have higher predictive ability for metabolic syndrome in men than in women. Copyright © 2016 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.
Chiplonkar, Shashi; Kajale, Neha; Ekbote, Veena; Mandlik, Rubina; Parthasarathy, Lavanya; Borade, Ashwin; Patel, Pinal; Patel, Prerna; Khadilkar, Vaman; Khadilkar, Anuradha
2017-12-15
To create gender-specific percentile curves for percent body fat (%BF) by Bio electrical Impedance Analysis (BIA) for screening adiposity and risk of hypertension in Indian children and generate reference curves for percent fat-free mass (%FFM), muscle mass (%LM) and bone mineral content (BMC) by using bioelectrical impedance. Secondary analysis of data from previous multicenter cross-sectional studies. Private schools from five regions of India. A random sample of 3850 healthy school children (2067 boys) (5-17 yr) from private schools in five major Indian cities. Anthropometry, blood pressure (BP) and body composition were measured by bioelectrical impedance. Reference curves were generated by the LMS method. %BF, %FFM, %LM, BMC and BP. Median %BF increased by 6% from 5 to 13 years of age and declined (around 2%) up to 17 years in boys. In girls, %BF increased by 8% from 5 to 14 years and thereafter declined by 3%. Based upon the risk of hypertension, the new cut-offs of 75th and 85th percentile of %BF were proposed for detecting over fatness and excess fatness in children. Median %FFM was 90% at 5 yrs and decreased till 12 years, and then showed a slight increase to 84% at 17 yrs in boys. In girls, it was 86% at 5 yrs and decreased till 15 yrs, and plateaued at 71.8% at 17 yrs. Reference curves for percent body fat for Indian children would be useful to screen children for health risk in clinical set up.
Stolarski, J.T.; Margraf, F.J.; Carlson, J.G.; Sutton, T.M.
2014-01-01
The physiological well-being or condition of fish is most commonly estimated from aspects of individual morphology. However, these metrics may be only weakly correlated with nutritional reserves stored as lipid, the primary form of accumulated energy in fish. We constructed and evaluated bioelectrical impedance analysis (BIA) models as an alternative method of assessing condition in amphidromous Dolly Varden Salvelinus malma collected from nearshore estuarine and lotic habitats of the Alaskan Arctic. Data on electrical resistance and reactance were collected from the lateral and ventral surfaces of 192 fish, and whole-body percent lipid and moisture content were determined using standard laboratory methods. Significant inverse relationships between temperature and resistance and reactance prompted the standardization of these data to a constant temperature using corrective equations developed herein. No significant differences in resistance or reactance were detected among spawning and nonspawning females after accounting for covariates, suggesting that electrical pathways do not intersect the gonads. Best-fit BIA models incorporating electrical variables calculated from the lateral and ventral surfaces produced the strongest associations between observed and model-predicted estimates of proximate content. These models explained between 6% and 20% more of the variability in laboratory-derived estimates of proximate content than models developed from single-surface BIA data and 32% more than models containing only length and weight data. While additional research is required to address the potential effects of methodological variation, bioelectrical impedance analysis shows promise as a way to provide high-quality, minimally invasive estimates of Dolly Varden lipid or moisture content in the field with only small increases in handling time.
Bioelectrical impedance analysis: A new tool for assessing fish condition
Hartman, Kyle J.; Margraf, F. Joseph; Hafs, Andrew W.; Cox, M. Keith
2015-01-01
Bioelectrical impedance analysis (BIA) is commonly used in human health and nutrition fields but has only recently been considered as a potential tool for assessing fish condition. Once BIA is calibrated, it estimates fat/moisture levels and energy content without the need to kill fish. Despite the promise held by BIA, published studies have been divided on whether BIA can provide accurate estimates of body composition in fish. In cases where BIA was not successful, the models lacked the range of fat levels or sample sizes we determined were needed for model success (range of dry fat levels of 29%, n = 60, yielding an R2 of 0.8). Reduced range of fat levels requires an increased sample size to achieve that benchmark; therefore, standardization of methods is needed. Here we discuss standardized methods based on a decade of research, identify sources of error, discuss where BIA is headed, and suggest areas for future research.
Ejlerskov, Katrine T.; Jensen, Signe M.; Christensen, Line B.; Ritz, Christian; Michaelsen, Kim F.; Mølgaard, Christian
2014-01-01
For 3-year-old children suitable methods to estimate body composition are sparse. We aimed to develop predictive equations for estimating fat-free mass (FFM) from bioelectrical impedance (BIA) and anthropometry using dual-energy X-ray absorptiometry (DXA) as reference method using data from 99 healthy 3-year-old Danish children. Predictive equations were derived from two multiple linear regression models, a comprehensive model (height2/resistance (RI), six anthropometric measurements) and a simple model (RI, height, weight). Their uncertainty was quantified by means of 10-fold cross-validation approach. Prediction error of FFM was 3.0% for both equations (root mean square error: 360 and 356 g, respectively). The derived equations produced BIA-based prediction of FFM and FM near DXA scan results. We suggest that the predictive equations can be applied in similar population samples aged 2–4 years. The derived equations may prove useful for studies linking body composition to early risk factors and early onset of obesity. PMID:24463487
Ejlerskov, Katrine T; Jensen, Signe M; Christensen, Line B; Ritz, Christian; Michaelsen, Kim F; Mølgaard, Christian
2014-01-27
For 3-year-old children suitable methods to estimate body composition are sparse. We aimed to develop predictive equations for estimating fat-free mass (FFM) from bioelectrical impedance (BIA) and anthropometry using dual-energy X-ray absorptiometry (DXA) as reference method using data from 99 healthy 3-year-old Danish children. Predictive equations were derived from two multiple linear regression models, a comprehensive model (height(2)/resistance (RI), six anthropometric measurements) and a simple model (RI, height, weight). Their uncertainty was quantified by means of 10-fold cross-validation approach. Prediction error of FFM was 3.0% for both equations (root mean square error: 360 and 356 g, respectively). The derived equations produced BIA-based prediction of FFM and FM near DXA scan results. We suggest that the predictive equations can be applied in similar population samples aged 2-4 years. The derived equations may prove useful for studies linking body composition to early risk factors and early onset of obesity.
Bioelectrical impedance analysis and anthropometry in Ecuadorian children of African ancestry.
Vienna, A; Capucci, E; De Stefano, G F; Hauser, G
1998-12-01
In the city of Esmeraldas, north-western coast of Ecuador, height, weight, and body composition of 600 male and female schoolchildren of African ancestry in the age groups four, five and six years were investigated. All the children were apparently healthy without any obvious or reported pathologies and in accordance with data from personal information were assigned to one of two socio-economic classes. The greater values for weight and height shown by children in the higher socio-economic group than in the less well off are compatible with those for more fat and water as obtained by the BIA investigation. Additional information on nutritional, muscular and general health status was obtained from positioning and degree of dispersion of the 'Biagram' ellipses. It seems that both the anthropometric and the bioelectrical impedance methods provide useful information on the differences due to belonging to one or other of the socio-economic groups.
Bioelectrical impedance analysis for bovine milk: Preliminary results
NASA Astrophysics Data System (ADS)
Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.
2010-04-01
This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.
Lee, Simon; Bountziouka, Vassiliki; Lum, Sooky; Stocks, Janet; Bonner, Rachel; Naik, Mitesh; Fothergill, Helen; Wells, Jonathan C K
2014-01-01
Bioelectrical Impedance Analysis (BIA) has the potential to be used widely as a method of assessing body fatness and composition, both in clinical and community settings. BIA provides bioelectrical properties, such as whole-body impedance which ideally needs to be calibrated against a gold-standard method in order to provide accurate estimates of fat-free mass. UK studies in older children and adolescents have shown that, when used in multi-ethnic populations, calibration equations need to include ethnic-specific terms, but whether this holds true for younger children remains to be elucidated. The aims of this study were to examine ethnic differences in body size, proportions and composition in children aged 5 to 11 years, and to establish the extent to which such differences could influence BIA calibration. In a multi-ethnic population of 2171 London primary school-children (47% boys; 34% White, 29% Black African/Caribbean, 25% South Asian, 12% Other) detailed anthropometric measurements were performed and ethnic differences in body size and proportion were assessed. Ethnic differences in fat-free mass, derived by deuterium dilution, were further evaluated in a subsample of the population (n = 698). Multiple linear regression models were used to calibrate BIA against deuterium dilution. In children < 11 years of age, Black African/Caribbean children were significantly taller, heavier and had larger body size than children of other ethnicities. They also had larger waist and limb girths and relatively longer legs. Despite these differences, ethnic-specific terms did not contribute significantly to the BIA calibration equation (Fat-free mass = 1.12+0.71*(height2/impedance)+0.18*weight). Although clear ethnic differences in body size, proportions and composition were evident in this population of young children aged 5 to 11 years, an ethnic-specific BIA calibration equation was not required.
Cova, Ilaria; Pomati, Simone; Maggiore, Laura; Forcella, Marica; Cucumo, Valentina; Ghiretti, Roberta; Grande, Giulia; Muzio, Fulvio; Mariani, Claudio
2017-01-01
Analysis of nutritional status and body composition in Alzheimer's disease (AD) and Mild Cognitive Impairment (MCI). A cross-sectional study was performed in a University-Hospital setting, recruiting 59 patients with AD, 34 subjects with MCI and 58 elderly healthy controls (HC). Nutritional status was assessed by anthropometric parameters (body mass index; calf, upper arm and waist circumferences), Mini Nutritional Assessment (MNA) and body composition by bioelectrical impedance vector analysis (BIVA). Variables were analyzed by analysis of variance and subjects were grouped by cognitive status and gender. Sociodemographic variables did not differ among the three groups (AD, MCI and HC), except for females' age, which was therefore used as covariate in a general linear multivariate model. MNA score was significantly lower in AD patients than in HC; MCI subjects achieved intermediate scores. AD patients (both sexes) had significantly (p<0.05) higher height-normalized impedance values and lower phase angles (body cell mass) compared with HC; a higher ratio of impedance to height was found in men with MCI with respect to HC. With BIVA method, MCI subjects showed a significant displacement on the RXc graph on the right side indicating lower soft tissues (Hotelling's T2 test: men = 10.6; women = 7.9;p < 0,05) just like AD patients (Hotelling's T2 test: men = 18.2; women = 16.9; p<0,001). Bioelectrical parameters significantly differ from MCI and AD to HC; MCI showed an intermediate pattern between AD and HC. Longitudinal studies are required to investigate if BIVA could reflect early AD-changes in body composition in subjects with MCI.
Cleary, Jane; Daniells, Suzie; Okely, Anthony D; Batterham, Marijka; Nicholls, Jessie
2008-01-01
Bioelectrical impedance equations are frequently used by food and nutrition professionals to estimate percent fat mass in overweight and obese children. However, it is not known whether they are accurate for such children, as they have been primarily developed for children of varying body weights. The aim of this cross-sectional study was to evaluate the predictive validity of four previously published prediction equations developed for the pediatric population, among a sample of overweight and obese children. Thirty overweight or obese children (mean age=7.57+/-1.28 years) underwent measurement of fat mass, percent fat mass, and fat-free mass using dual-energy x-ray absorptiometry (DEXA) and bioelectrical impedance analysis (BIA). Impedance values from the BIA were entered into the four prediction equations and Pearson correlations used to determine the significance of associations between each of the BIA prediction equations and DEXA for percent fat mass, fat mass, and fat-free mass. For percent fat mass, paired t tests were used to assess differences between the methods and the technique of Bland and Altman was used to determine bias and error. Results showed that the mean percent fat mass as determined by DEXA for this age group was 40.79%. In comparison with other BIA prediction equations, the Schaefer equation had the closest mean value of 41.98%, and was the only equation not to significantly differ from the DEXA (P=0.121). This study suggests that the Schaefer equation is the only accurate BIA prediction equation for assessing percent fat mass in this sample of overweight and obese children from primarily white backgrounds.
Fernández Vázquez, Rosalía; Martínez Blanco, Javier; García Vega, María del Mar; Barbancho, Miguel Ángel; Alvero-Cruz, José Ramón
2015-11-01
to know the changes in trunk fat and visceral fat level determined by abdominal bioelectrical impedance (BIA) as well as other anthropometric measures related to the central or abdominal fat after the ingestion of a lunch. the experimental study was conducted to assess a longitudinal intervention descriptive study. 21 subjects (10 male and 11 female), volunteers who have access to a medical assessment, with an age of 74 ± 13.43 years. Maximal waist circumference in standing position, waist circumference at navel level in supine position and sagittal abdominal diameter (SAD). In the same position trunk fat and visceral fat level by abdominal bioelectrical impedance analysis with Tanita AB-140 (ViScan) were obtained before and after meal. anthropometric measures as waist circumference in supine position and SAD did not show significant differences (P > 0.05), after food ingestion, except for a significant increase of the maximal waist circumference in standing position (P < 0.05). In addition trunk fat and visceral fat ratio did not change (P > 0.05). The percentage changes of the measures were less than 2% for waist circumference in standing position, waist circumference by Viscan, sagittal abdominal diameter and trunk fat and 5.9% for visceral fat ratio. the effects on trunk fat and visceral fat ratio by abdominal bioelectrical impedance are minimal after the ingestion of a portion of food and drink, although it is always recommended to do it in fasting conditions. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Newby, M.J.; Keim, N.L.; Brown, D.L.
1990-08-01
This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg lessmore » lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients.« less
Yılmaz, Dilek; Sönmez, Ferah; Karakaş, Sacide; Yavaşcan, Önder; Aksu, Nejat; Ömürlü, İmran Kurt; Yenisey, Çiğdem
2016-06-01
Malnutrition is one of the major causes of morbidity and mortality in children with chronic kidney disease (CKD). The objective of this study was to evaluate nutritional status of children with stage 3-4 CKD and treated by peritoneal dialysis or hemodialysis using anthropometric measurements, biochemical parameters and bioelectrical impedance analysis. The study included a total of 52 patients and 46 healthy children. In anthropometric evaluation, the children with CKD had lower values for standard deviation score for weight, height, body mass index, skinfold thickness and mid-arm circumference than those of healthy children (p < 0.05). The fat mass (%) and the body cell mass (%) measurements performed by bioelectrical impedance analysis were lower compared with the control group (p < 0.05). It is considered that bioelectrical impedance analysis measurement should be used with anthropometric measurements, which are easy to perform, to achieve more accurate nutritional evaluation in children. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dehesa-López, Edgar; Martínez-Felix, Jesús Israel; Ruiz-Ramos, Arturo; Atilano-Carsi, Ximena
2017-04-01
No universally accepted diagnostic criteria for malnutrition are available to date. The aim was to assess the concordance for the diagnosis of hospital malnutrition between the bioelectrical impedance vector analysis (BIVA) and the new definition of malnutrition proposed by the European Society for Clinical Nutrition and Metabolism (ESPEN). A total of 140 adult hospitalized patients were included. The malnutrition risk was assessed by the Nutritional Risk Screening. The ESPEN malnutrition criteria (body mass index (BMI) <18.5 kg/m 2 , weight loss (WL) + low BMI, and WL + low fat free mass index (FFMI) were applied to each patient. The bioelectrical impedance of each patient was measured, and malnutrition was diagnosed using the BIVA method. Diagnostic concordance between the BIVA and the new ESPEN definition was assessed with the Kappa coefficient. The malnutrition prevalence was higher with the BIVA vs ESPEN definition (22.1% vs 13.6%) in the global population and was similar (12.8% vs 12.1%) in the population at risk of malnutrition. The diagnostic performance of the BIVA was acceptable, with higher sensitivity in patients with fluid overload (FO) and more specificity in euvolemic patients. Diagnostic concordance between the BIVA and the ESPEN definition was poor for the global population (kappa = 0.56) and the population at risk of malnutrition (kappa = 0.67) but was acceptable in patients with FO (kappa = 0.78). However, the discordant BIVA+/ESPEN- patients classified as false positives for BIVA showed clinical and body composition data (low FFMI, low phase angle) consistent with malnutrition. According to the clinical and bioelectrical characteristics of the discordant BIVA+/ESPEN- patients, the BIVA could perform better that the new ESPEN definition for the diagnosis of hospital malnutrition, which should be confirmed with other studies. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.
Erceg, David N; Dieli-Conwright, Christina M; Rossuello, Amerigo E; Jensky, Nicole E; Sun, Stephanie; Schroeder, E Todd
2010-05-01
Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.
Schoenfeld, Brad J; Nickerson, Brett S; Wilborn, Colin D; Urbina, Stacie L; Hayward, Sara B; Krieger, James; Aragon, Alan A; Tinsley, Grant M
2018-06-20
Schoenfeld, BJ, Nickerson, BS, Wilborn, CD, Urbina, SL, Hayward, SB, Krieger, J, Aragon, AA, and Tinsley, G. Comparison of multifrequency bioelectrical impedance vs. dual-energy x-ray absorptiometry for assessing body composition changes after participation in a 10-week resistance training program. J Strength Cond Res XX(X): 000-000, 2018-The purpose of this study was to assess the ability of multifrequency bioelectrical impedance analysis (MF-BIA) to determine alterations in total and segmental body composition across a 10-week resistance training (RT) program in comparison with the criterion reference dual-energy X-ray absorptiometry (DXA). Twenty-one young male volunteers (mean ± SD; age = 22.9 ± 3.0 years; height = 175.5 ± 5.9 cm; body mass = 82.9 ± 13.6 kg; body mass index = 26.9 ± 3.6) performed an RT program that included exercises for all major muscle groups. Body composition was assessed using both methods before and after the intervention; change scores were determined by subtracting pre-test values from post-test values for percent body fat ([INCREMENT]%BF), fat mass ([INCREMENT]FM), and fat-free mass ([INCREMENT]FFM). Mean changes were not significantly different when comparing MF-BIA with DXA for [INCREMENT]%BF (-1.05 vs. -1.28%), [INCREMENT]FM (-1.13 vs. -1.19 kg), and FFM (0.10 vs. 0.37 kg, respectively). Both methods showed strong agreement for [INCREMENT]%BF (r = 0.75; standard error of the estimate [SEE] = 1.15%), [INCREMENT]FM (r = 0.84; SEE 1.0 kg), and [INCREMENT]FFM (r = 0.71; SEE of 1.5 kg). The 2 methods were poor predictors of each other in regards to changes in segmental measurements. Our data indicate that MF-BIA is an acceptable alternative for tracking changes in FM and FFM during a combined diet and exercise program in young, athletic men, but segmental lean mass measurements must be interpreted with circumspection.
Fernández-Vázquez, Rosalía; Millán Romero, Ángel; Barbancho, Miguel Ángel; Alvero-Cruz, José Ramón
2015-09-01
central obesity has a higher risk of metabolic syndrome. The present work aimed to study the relationship of trunk fat and the visceral fat index, and other anthropometric indices in relation to the metabolic syndrome in middle aged male Methods: design: transversal descriptive and correlational study. 75 male, volunteers who have access to a medical assessment, with an age range of 21 to 59 years, from different professions. Weight, height, body mass index, waist circumference, gluteal circumference, waist-to-hip ratio, waist-to-height ratio, trunk fat and visceral fat level by bioelectrical abdominal impedance analysis with Tanita AB-140 (ViScan) and biochemical markers: fasting glucose, total cholesterol, and triglycerides. Likewise, the systolic and diastolic blood pressure was measured. there are significant correlations of anthropometric measurements with trunk fat and visceral fat level and the same with biochemical variables. Receptor-operator curves (ROC curve) analysis shows that the cutoff points from which arises the metabolic syndrome are 32.7% of trunk fat and a level of visceral fat of 13 with a high sensitivity and specificity, attaining the same cut-off points for the metabolic syndrome and obesity status. trunk fat and visceral fat levels determined by bioelectrical abdominal impedance analysis, values are variables very sensitive and specific for the detection of metabolic syndrome and obesity, though not over the variables and anthropometric indices. In the condition of the overweight, trunk fat and visceral fat level are more predictive than anthropometric measures. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Validity of Bioelectrical Impedance Analysis to Estimation Fat-Free Mass in the Army Cadets.
Langer, Raquel D; Borges, Juliano H; Pascoa, Mauro A; Cirolini, Vagner X; Guerra-Júnior, Gil; Gonçalves, Ezequiel M
2016-03-11
Bioelectrical Impedance Analysis (BIA) is a fast, practical, non-invasive, and frequently used method for fat-free mass (FFM) estimation. The aims of this study were to validate predictive equations of BIA to FFM estimation in Army cadets and to develop and validate a specific BIA equation for this population. A total of 396 males, Brazilian Army cadets, aged 17-24 years were included. The study used eight published predictive BIA equations, a specific equation in FFM estimation, and dual-energy X-ray absorptiometry (DXA) as a reference method. Student's t-test (for paired sample), linear regression analysis, and Bland-Altman method were used to test the validity of the BIA equations. Predictive BIA equations showed significant differences in FFM compared to DXA (p < 0.05) and large limits of agreement by Bland-Altman. Predictive BIA equations explained 68% to 88% of FFM variance. Specific BIA equations showed no significant differences in FFM, compared to DXA values. Published BIA predictive equations showed poor accuracy in this sample. The specific BIA equations, developed in this study, demonstrated validity for this sample, although should be used with caution in samples with a large range of FFM.
Cornish, B H; Ward, L C; Thomas, B J; Jebb, S A; Elia, M
1996-03-01
To assess the application of a Cole-Cole analysis of multiple frequency bioelectrical impedance analysis (MFBIA) measurements to predict total body water (TBW) and extracellular water (ECW) in humans. This technique has previously been shown to produce accurate and reliable estimates in both normal and abnormal animals. The whole body impedance of 60 healthy humans was measured at 496 frequencies (ranging from 4 kHz to 1 MHz) and the impedance at zero frequency, Ro, and at the characteristic frequency, Zc, were determined from the impedance spectrum, (Cole-Cole plot). TBW and ECW were independently determined using deuterium and bromide tracer dilution techniques. At the Dunn Clinical Nutrition Centre and The Department of Biochemistry, University of Queensland. 60 healthy adult volunteers (27 men and 33 women, aged 18-45 years). The results presented suggest that the swept frequency bioimpedance technique estimates total body water, (SEE = 5.2%), and extracellular water, (SEE = 10%), only slightly better in normal, healthy subjects than a method based on single frequency bioimpedance or anthropometric estimates based on weight, height and gender. This study has undertaken the most extensive analysis to date of relationships between TBW (and ECW) and individual impedances obtained at different frequencies ( > 400 frequencies), and has shown marginal advantages of using one frequency over another, even if values predicted from theoretical bioimpedance models are used in the estimations. However in situations where there are disturbances of fluid distribution, values predicted from the Cole-Cole analysis of swept frequency bioimpedance measurements could prove to be more useful.
Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Faisal, Tarig; Neuman, Michael
2015-03-23
This paper reviews a number of biomedical engineering approaches to help aid in the detection and treatment of tropical diseases such as dengue, malaria, cholera, schistosomiasis, lymphatic filariasis, ebola, leprosy, leishmaniasis, and American trypanosomiasis (Chagas). Many different forms of non-invasive approaches such as ultrasound, echocardiography and electrocardiography, bioelectrical impedance, optical detection, simplified and rapid serological tests such as lab-on-chip and micro-/nano-fluidic platforms and medical support systems such as artificial intelligence clinical support systems are discussed. The paper also reviewed the novel clinical diagnosis and management systems using artificial intelligence and bioelectrical impedance techniques for dengue clinical applications.
Method of recording bioelectrical signals using a capacitive coupling
NASA Astrophysics Data System (ADS)
Simon, V. A.; Gerasimov, V. A.; Kostrin, D. K.; Selivanov, L. M.; Uhov, A. A.
2017-11-01
In this article a technique for the bioelectrical signals acquisition by means of the capacitive sensors is described. A feedback loop for the ultra-high impedance biasing of the input instrumentation amplifier, which provides receiving of the electrical cardiac signal (ECS) through a capacitive coupling, is proposed. The mains 50/60 Hz noise is suppressed by a narrow-band stop filter with an independent notch frequency and quality factor tuning. Filter output is attached to a ΣΔ analog-to-digital converter (ADC), which acquires the filtered signal with a 24-bit resolution. Signal processing board is connected through universal serial bus interface to a personal computer, where ECS in a digital form is recorded and processed.
Qualitative human body composition analysis assessed with bioelectrical impedance.
Talluri, T
1998-12-01
Body composition is generally aiming at quantitative estimates of fat mass, inadequate to assess nutritional states that on the other hand are well defined by the intra/extra cellular masses proportion (ECM/BCM). Direct measures performed with phase sensitive bioelectrical impedance analyzers can be used to define the current distribution in normal and abnormal populations. Phase angle and reactance nomogram is directly reflecting the ECM/BCM pathways proportions and body impedance analysis (BIA) is also validated to estimate the individual content of body cell mass (BCM). A new body cell mass index (BCMI) obtained dividing the weight of BCM in kilograms by the body surface in square meters is confronted to the scatterplot distribution of phase angle and reactance values obtained from controls and patients, and proposed as a qualitative approach to identify abnormal ECM/BCM ratios and nutritional states.
An evaluation of a bioelectrical impedance analyser for the estimation of body fat content.
Maughan, R J
1993-01-01
Measurement of body composition is an important part of any assessment of health or fitness. Hydrostatic weighing is generally accepted as the most reliable method for the measurement of body fat content, but is inconvenient. Electrical impedance analysers have recently been proposed as an alternative to the measurement of skinfold thickness. Both these latter methods are convenient, but give values based on estimates obtained from population studies. This study compared values of body fat content obtained by hydrostatic weighing, skinfold thickness measurement and electrical impedance on 50 (28 women, 22 men) healthy volunteers. Mean(s.e.m.) values obtained by the three methods were: hydrostatic weighing, 20.5(1.2)%; skinfold thickness, 21.8(1.0)%; impedance, 20.8(0.9)%. The results indicate that the correlation between the skinfold method and hydrostatic weighing (0.931) is somewhat higher than that between the impedance method and hydrostatic weighing (0.830). This is, perhaps, not surprising given the fact that the impedance method is based on an estimate of total body water which is then used to calculate body fat content. The skinfold method gives an estimate of body density, and the assumptions involved in the conversion from body density to body fat content are the same for both methods. PMID:8457817
Isenring, E; Colombo, M; Cross, G; Kellett, E; Swaney, L
2009-02-01
Bioelectrical impedance spectroscopy (BIS) may be more accurate in determining total body water (TBW) than bioelectrical impedance analysis (BIA). The present study compared the agreement between three TBW prediction equations developed using BIA and BIS-derived TBW in oncology outpatients. A cross-sectional, observational study was conducted in 37 outpatients receiving radiotherapy (27 males/10 females, aged 68.3 +/- 10.2 years). TBW was estimated by BIS (TBW(BIS)) and three BIA TBW prediction equations (TBW(ca-u): underweight cancer patients; TBW(ca-n): normal-weight cancer patients; and TBW(rad): patients receiving radiotherapy). Bland-Altman analyses determined agreement between methods. BIS-derived TBW using new resistivity constants was calculated. The mean +/- SD of TBW estimated by BIS was 39.8 +/- 8.3 L, which was significantly different from the prediction equations; TBW(rad) 35.1 +/- 7.9 L, TBW(ca-u) 33.1 +/- 7.5 L and TBW(ca-n) 32.3 +/- 7.3 L, (P < 0.001). Using new resistivity constants, TBW was 36.2 +/- 8.1 L but this still differed from the equations (P < 0.001). Bias between TBW(BIS) and that predicted by the equations was in the range 4.7-7.4 L or 1.1-3.9 L using new resistivity constants. TBW estimated by BIS cannot be directly compared with oncology-specific BIA equations, suggesting that BIS cannot be used at the group level in outpatients receiving radiotherapy. There was a reduced bias with BIS using new resistivity constants; however, further research should determine any advantage of BIS over BIA in this population.
Kudsk, Kenneth A.; Munoz-del-Rio, Alejandro; Busch, Rebecca A.; Kight, Cassandra E.; Schoeller, Dale A.
2015-01-01
Background Loss of protein mass and lower fat-free mass index (FFMI) are associated with longer length of stay, post-surgical complications and other poor outcomes in hospitalized patients Normative data for FFMI of U.S. populations does not exist. This work aims to create a stratified FFMI percentile table for the U.S. population using the large bioelectric impedance analysis data obtained from National Health and Nutrition Examination Surveys (NHANES). Methods Fat-free mass (FFM) was calculated from the NHANES III bioelectric impedance analysis and anthropometric data for males and females ages 12 to over 90 years for three race-ethnicities (non-Hispanic white, non-Hispanic black, and Mexican-American). FFM was normalized by subject height to create a FFMI distribution table for the U.S. population. Selected percentiles were obtained by age, sex, and race-ethnicity. Data was collapsed by race-ethnicity before and after removing obese and underweight subjects to create a FFMI decile table for males and females aged 12 and over for the healthy weight U.S. population. Results FFMI increased during adolescent growth but stabilized in the early 20s. The FFMI deciles were similar by race-ethnicity and age group remaining relatively stable between ages of 22 and 80 years. The FFMI deciles for males and females were significantly different. Conclusions After eliminating the obese and extremely thin, FFMI percentiles remain stable during adult years allowing creation of age- and race/ethnicity-independent decile tables for males and females. These tables allow stratification of individuals for nutrition intervention trials to depict changing nutrition status during medical, surgical and nutritional interventions. PMID:26092851
USDA-ARS?s Scientific Manuscript database
In three separate studies (156 pigs total), DXA, BIA, and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body l...
Lactate threshold by muscle electrical impedance in professional rowers
NASA Astrophysics Data System (ADS)
Jotta, B.; Coutinho, A. B. B.; Pino, A. V.; Souza, M. N.
2017-04-01
Lactate threshold (LT) is one of the physiological parameters usually used in rowing sport training prescription because it indicates the transitions from aerobic to anaerobic metabolism. Assessment of LT is classically based on a series of values of blood lactate concentrations obtained during progressive exercise tests and thus has an invasive aspect. The feasibility of noninvasive LT estimative through bioelectrical impedance spectroscopy (BIS) data collected in thigh muscles during rowing ergometer exercise tests was investigated. Nineteen professional rowers, age 19 (mean) ± 4.8 (standard deviation) yr, height 187.3 ± 6.6 cm, body mass 83 ± 7.7 kg, and training experience of 7 ± 4 yr, were evaluated in a rowing ergometer progressive test with paired measures of blood lactate concentration and BIS in thigh muscles. Bioelectrical impedance data were obtained by using a bipolar method of spectroscopy based on the current response to a voltage step. An electrical model was used to interpret BIS data and to derive parameters that were investigated to estimate LT noninvasively. From the serial blood lactate measurements, LT was also determined through Dmax method (LTDmax). The zero crossing of the second derivative of kinetic of the capacitance electrode (Ce), one of the BIS parameters, was used to estimate LT. The agreement between the LT estimates through BIS (LTBIS) and through Dmax method (LTDmax) was evaluated using Bland-Altman plots, leading to a mean difference between the estimates of just 0.07 W and a Pearson correlation coefficient r = 0.85. This result supports the utilization of the proposed method based on BIS parameters for estimating noninvasively the lactate threshold in rowing.
Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Faisal, Tarig; Neuman, Michael
2015-01-01
This paper reviews a number of biomedical engineering approaches to help aid in the detection and treatment of tropical diseases such as dengue, malaria, cholera, schistosomiasis, lymphatic filariasis, ebola, leprosy, leishmaniasis, and American trypanosomiasis (Chagas). Many different forms of non-invasive approaches such as ultrasound, echocardiography and electrocardiography, bioelectrical impedance, optical detection, simplified and rapid serological tests such as lab-on-chip and micro-/nano-fluidic platforms and medical support systems such as artificial intelligence clinical support systems are discussed. The paper also reviewed the novel clinical diagnosis and management systems using artificial intelligence and bioelectrical impedance techniques for dengue clinical applications. PMID:25806872
Kasvis, Popi; Cohen, Tamara R; Loiselle, Sarah-Ève; Kim, Nicolas; Hazell, Tom J; Vanstone, Catherine A; Rodd, Celia; Plourde, Hugues; Weiler, Hope A
2015-03-01
Body composition measurements are valuable when evaluating pediatric obesity interventions. We hypothesized that foot-to-foot bioelectrical impedance analysis (BIA) will accurately track the direction of adiposity change, but not magnitude, in part due to differences in fat patterning. The purposes of this study were to examine the accuracy of body composition measurements of overweight and obese children over time using dual-energy x-ray absorptiometry (DXA) and BIA and to determine if BIA accuracy was affected by fat patterning. Eighty-nine overweight or obese children (48 girls, 41 boys, age 7-13 years) participating in a randomized controlled trial providing a family-centered, lifestyle intervention, underwent DXA and BIA measurements every 3 months. Bland-Altman plots showed a poor level of agreement between devices for baseline percent body fat (%BF; mean, 0.398%; +2SD, 8.685%; -2SD, -7.889%). There was overall agreement between DXA and BIA in the direction of change over time for %BF (difference between visits 3 and 1: DXA -0.8 ± 0.5%, BIA -0.7 ± 0.5%; P = 1.000) and fat mass (FM; difference between visits 3 and 1: DXA 0.7 ± 0.5 kg, BIA 0.6 ± 0.5 kg; P = 1.000). Bioelectrical impedance analysis measurements of %BF and FM at baseline were significantly different in those with android and gynoid fat (%BF: 35.9% ± 1.4%, 32.2% ± 1.4%, P < .003; FM: 20.1 ± 0.8 kg, 18.4 ± 0.8, P < .013). Bioelectrical impedance analysis accurately reports the direction of change in FM and FFM in overweight and obese children; inaccuracy in the magnitude of BIA measurements may be a result of fat patterning differences. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Siconolfi, Steven F. (Inventor)
2000-01-01
Method and apparatus are described for determining volumes of body fluids in a subject using bioelectrical response spectroscopy. The human body is represented using an electrical circuit. Intra-cellular water is represented by a resistor in series with a capacitor; extra-cellular water is represented by a resistor in series with two parallel inductors. The parallel inductors represent the resistance due to vascular fluids. An alternating, low amperage, multifrequency signal is applied to determine a subject's impedance and resistance. From these data, statistical regression is used to determine a 1% impedance where the subject's impedance changes by no more than 1% over a 25 kHz interval. Circuit component, of the human body circuit are determined based on the 1% impedance. Equations for calculating total body water, extra-cellular water, total blood volume, and plasma volume are developed based on the circuit components.
Anthropometric methods for obesity screening in schoolchildren: the Ouro Preto Study.
Cándido, A P C; Alosta, J P S; Oliveira, C T; Freitas, R N; Freitas, S N; Machado-Coelho, G L L
2012-01-01
Childhood obesity is increasing dramatically in last decades. To evaluate the usefulness of body mass index (BMI), skinfold thickness (ST), waist circumference (WC), and foot-to-foot bioelectrical impedance (BIA-FF) for screening for obesity in mixed-race population, using the tetrapolar bioelectrical impedance (BIA-T) technique as reference method. A cross-sectional-based population study was performed in the city of Ouro Preto, Brazil, in 2006. Schoolchildren aged 6-15 years (n = 788) was randomly selected according to age and sex stratified by the proportion of students in each schools of the city. Nonparametric receiver operating characteristic (ROC) analysis was used to define the sensitivity and specificity for each method studied using the tetrapolar method as reference. The BMI and the BIA-FF were the most suitable for adiposity screening in pre-pubertal and pubertal stages because they present a better balance between sensitivity and specificity, and smaller misclassification. For post-pubertal boys, the BF-ST-D was the best body fat assessment method. The results suggest that BIA-FF and BMI are choice methods for obesity screening in mixed population and that the method choice for body fat screening must be done according to sexual maturity of boys and girls. The present study demonstrates the need to perform studies in wider mixed-race population to determine anthropometric parameters and to examine the predictive ability of methods and cut-offs here elucidated in the development of obesity.
Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C
2016-06-01
Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs. Copyright © 2016. Published by Elsevier Ltd.
Estimation of limb adiposity by bioimpedance spectroscopy in lymphoedema
NASA Astrophysics Data System (ADS)
Ward, L. C.; Essex, T.; Gaw, R.; Czerniec, S.; Dylke, E.; Abell, B.; Kilbreath, S. L.
2013-04-01
Lymphoedema is a chronic debilitating condition that may occur in approximately 25% of women treated for breast cancer. As the condition progresses, accumulated lymph fluid becomes fibrotic with infiltration of adipose tissue. Bioelectrical impedance spectroscopy is the preferred method for early detection of lymphoedema based on the measurement of impedance of extracellular fluid. The present study assessed whether these impedance measurements could also be used to estimate the adipose tissue content of the arm based on a model previously used to predict whole body composition. Estimates of arm adipose tissue in a cohort of women with lymphoedema were found to be highly correlated (r > 0.82) with measurements of adipose tissue obtained using the reference method of dual energy X-ray absorptiometry. Paired t-tests confirmed that there was no significant difference between the adipose tissue volumes obtained by the two methods. These results support the view that the method shows promise for the estimation of arm adiposity in lymphoedema.
Bioelectrical impedance vector distribution in the first year of life.
Savino, Francesco; Grasso, Giulia; Cresi, Francesco; Oggero, Roberto; Silvestro, Leandra
2003-06-01
We assessed the bioelectrical impedance vector distribution in a sample of healthy infants in the first year of life, which is not available in literature. The study was conducted as a cross-sectional study in 153 healthy Caucasian infants (90 male and 63 female) younger than 1 y, born at full term, adequate for gestational age, free from chronic diseases or growth problems, and not feverish. Z scores for weight, length, cranial circumference, and body mass index for the study population were within the range of +/-1.5 standard deviations according to the Euro-Growth Study references. Concurrent anthropometrics (weight, length, and cranial circumference), body mass index, and bioelectrical impedance (resistance and reactance) measurements were made by the same operator. Whole-body (hand to foot) tetrapolar measurements were performed with a single-frequency (50 kHz), phase-sensitive impedance analyzer. The study population was subdivided into three classes of age for statistical analysis: 0 to 3.99 mo, 4 to 7.99 mo, and 8 to 11.99 mo. Using the bivariate normal distribution of resistance and reactance components standardized by the infant's length, the bivariate 95% confidence limits for the mean impedance vector separated by sex and age groups were calculated and plotted. Further, the bivariate 95%, 75%, and 50% tolerance intervals for individual vector measurements in the first year of life were plotted. Resistance and reactance values often fluctuated during the first year of life, particularly as raw measurements (without normalization by subject's length). However, 95% confidence ellipses of mean vectors from the three age groups overlapped each other, as did confidence ellipses by sex for each age class, indicating no significant vector migration during the first year of life. We obtained an estimate of mean impedance vector in a sample of healthy infants in the first year of life and calculated the bivariate values for an individual vector (95%, 75%, and 50% tolerance ellipses).
Demura, S; Yamaji, S; Goshi, F; Nagasawa, Y
2002-03-01
The purpose of this study was to clarify the influence of change of total body water caused by exercise and drinking, on relative body fat (%BF) based on three bioelectrical impedance analyses (BIA) methods, between hand and foot (H-F), between hand and hand (H-H), and between foot and foot (F-F). The subjects were 30 Japanese healthy young adults aged 18 to 23 years (15 males, 15 females). Measurements were made three times for each BIA method; before and after exercise with sweat, and after drinking, and also twice according to the under water weighing (UW) method, before exercise and after drinking. A pedaling exercise, with a bicycle ergometer, was used for 60 minutes as the exercise. The relationship of %BF between the UW method and each BIA method was mid-range or more (r=0.765-0.839). However, %BF based on the H-F and F-F BIA methods were higher than that based on the UW method. After drinking, %BF of all the BIA methods were higher than the UW method. %BF of the BIA methods after exercise indicated values lower than those before exercise. %BF of the H-F and H-H BIA methods after drinking were a little higher than those before exercise, indicating that those measurements reflect a slight change of body water. It was demonstrated that %BF of any BIA method reflect the change of body water caused by exercise, sweating, and drinking.
ERIC Educational Resources Information Center
Finn, Kevin J.; Saint-Maurice, Pedro F.; Karsai, István; Ihász, Ferenc; Csányi, Tamás
2015-01-01
Purpose: The purpose of this study was to test the convergent validity of Omron 306 using Biospace InBody 720. Method: A total of 267 participants (145 boys; aged 10.4-17.9 years) completed testing during a single session. Each measure provided percent body fat (%BF), while the InBody 720 included fat-free mass (FFM). The validity was examined…
Huguel, Benjamin; Vaugrenard, Thibaud; Saby, Ludivine; Benhamou, Lionel; Arméro, Sébastien; Camilleri, Élise; Langar, Aida; Alitta, Quentin; Grino, Michel; Retornaz, Frédérique
2018-06-01
Chronic heart failure (CHF) is a major public health matter. Mainly affecting the elderly, it is responsible for a high rate of hospitalization due to the frequency of acute heart failure (ADHF). This represents a disabling pathology for the patient and very costly for the health care system. Our study is designed to assess a connected and portable bioelectrical impedance analysis (BIA) that could reduce these hospitalizations by preventing early ADHF. This prospective study included patients hospitalized in cardiology for ADHF. Patients achieved 3 self-measurements using the BIA during their hospitalization and answered a questionnaire evaluating the acceptability of this self-measurement. The results of these measures were compared with the clinical, biological and echocardiographic criteria of patients at the same time. Twenty-three patients were included, the self-measurement during the overall duration of the hospitalization was conducted autonomously by more than 80% of the patients. The acceptability (90%) for the use of the portable BIA was excellent. Some correlations were statistically significant, such as the total water difference to the weight difference (p=0.001). There were common trends between the variation of impedance analysis measures and other evaluation criteria. The feasibility and acceptability of a self-measurement of bioelectrical impedance analysis by the patient in AHF opens up major prospects in the management of monitoring patients in CHF. The interest of this tool is the prevention of ADHF leading to hospitalization or re-hospitalizations now requires to be presented by new studies.
Ohta, Megumi; Midorikawa, Taishi; Hikihara, Yuki; Masuo, Yoshihisa; Sakamoto, Shizuo; Torii, Suguru; Kawakami, Yasuo; Fukunaga, Tetsuo; Kanehisa, Hiroaki
2017-02-01
This study examined the validity of segmental bioelectrical impedance (BI) analysis for predicting the fat-free masses (FFMs) of whole-body and body segments in children including overweight individuals. The FFM and impedance (Z) values of arms, trunk, legs, and whole body were determined using a dual-energy X-ray absorptiometry and segmental BI analyses, respectively, in 149 boys and girls aged 6 to 12 years, who were divided into model-development (n = 74), cross-validation (n = 35), and overweight (n = 40) groups. Simple regression analysis was applied to (length) 2 /Z (BI index) for each of the whole-body and 3 segments to develop the prediction equations of the measured FFM of the related body part. In the model-development group, the BI index of each of the 3 segments and whole body was significantly correlated to the measured FFM (R 2 = 0.867-0.932, standard error of estimation = 0.18-1.44 kg (5.9%-8.7%)). There was no significant difference between the measured and predicted FFM values without systematic error. The application of each equation derived in the model-development group to the cross-validation and overweight groups did not produce significant differences between the measured and predicted FFM values and systematic errors, with an exception that the arm FFM in the overweight group was overestimated. Segmental bioelectrical impedance analysis is useful for predicting the FFM of each of whole-body and body segments in children including overweight individuals, although the application for estimating arm FFM in overweight individuals requires a certain modification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ran, E-mail: liuran@tsinghua.edu.cn; Yang, Xueyao; Chen, Weixing
2013-11-04
A method of manufacturing three-dimension microneedle electrode arrays is presented in this paper using the micromolding technology with liquid metal at room temperature, based on the physical property of the Bi-In-Sn liquid metal alloy, being its melting point especially low. Observed under scanning electron microscopy, the needle body of the electrode chip manufactured using this method has a good consistency. Skin penetration test in-vitro indicates that the microneedle electrode can pierce the stratum corneum and cross the high-impedance layer to acquire electrical signals. Electrical impedance and polarization voltage experimental results show that the electrode chips have great electric characteristics andmore » meet the practical application demands.« less
Biaggi, R R; Vollman, M W; Nies, M A; Brener, C E; Flakoll, P J; Levenhagen, D K; Sun, M; Karabulut, Z; Chen, K Y
1999-05-01
Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 other established techniques, hydrostatic weighing (HW) and bioelectrical impedance analysis (BIA), in adults. The sample consisted of healthy men (n = 23) and women (n = 24). %BF was measured by AP, HW, and BIA. In the total group, %BF(AP) (25.0+/-8.9%) was not significantly different from %BF(HW) (25.1+/-7.7%) or %BF(BIA) (23.9+/-7.7%), and %BF(AP) was significantly correlated with %BF(HW) (r = 0.944, P < 0.001) and with %BF(BIA) (r = 0.859, P < 0.01). Compared with HW, AP underestimated %BF in men (by -1.24+/-3.12%) but overestimated %BF in women (by 1.02+/-2.48%), indicating a significant sex effect (P < 0.05). The differences in estimation between AP and BIA and between BIA and HW were not significantly different between the sexes. AP is an accurate method for assessing body composition in healthy adults. Future studies should assess further the cause of the individual variations with this new method.
Impact of eating and drinking on body composition measurements by bioelectrical impedance.
Androutsos, O; Gerasimidis, K; Karanikolou, A; Reilly, J J; Edwards, C A
2015-04-01
Bioelectrical impedance analysis would be a more practical tool to measure body composition in clinical settings, dietetic practice and epidemiological studies if patients/subjects did not have to fast before measurements. The present study assessed whether the ingestion of food or drink had any biologically significant effect on bioimpedance measurements and body composition by the foot-to-foot method. Fifty-five healthy adults [30 males and 25 females; mean (SD) age 27.7 (7.1) years; mean (SD)body mass index 24 (3.8) kg m(-2)] were randomly assigned to a 2-day food trial (high-fat meal or high-carbohydrate meal) or a 2-day drink trial (water or high electrolyte drink). Body composition measurements were carried out in the fasting state, immediately after meal consumption and every 30 min for 2 h by the foot-to-foot single frequency bioimpedance technique. Bioimpedance increased significantly after the ingestion of food and fluid, although the changes were small. The electrolyte drink, high-fat and high-carbohydrate meals significantly increased the percentage body fat and fat mass. In all cases, the median percentage changes from baseline were approximately 1% in body fat percentage units. Although there were statistically significant changes in body composition estimates after food or drink consumption, these were small and within the imprecision of the impedance technique, and so are unlikely to be of clinical significance. The present study suggests that impedance measures of body fatness in clinical settings do not require strict adherence to fasting, and this should increase the opportunities for clinical application. © 2014 The British Dietetic Association Ltd.
Bioelectrical impedance analysis. What does it measure?
NASA Technical Reports Server (NTRS)
Schoeller, D. A.
2000-01-01
Bioelectrical impedance analysis (BIA) has been proposed for measuring fat-free mass, total body water, percent fat, body cell mass, intracellular water, and extracellular water: a veritable laboratory in a box. Although it is unlikely that BIA is quite this versatile, correlations have been demonstrated between BIA and all of these body compartments. At the same time, it is known that all of the compartments are correlated among themselves. Because of this, it is difficult to determine whether BIA is specific for any or all of these compartments. To investigate this question, we induced acute changes in total body water and its compartments over a 3-h period. Using this approach, we demonstrated that multifrequency BIA, using the Cole-Cole model to calculate the zero frequency and infinite frequency resistance, measures extracellular and intracellular water.
Da, J J; Peng, H Y; Lin, X; Shen, Y; Zhao, J Q; He, S; Zha, Y
2018-03-27
Objective: To explore the level of resting energy expenditure (REE) estimated by bioelectrical impedance analysis and the association of resting metabolic rate (RMR) with clinical related factors, and provide new ideas for improving protein energy wasting (PEW) in maintenance hemodialysis (MHD) patients. Methods: Seven hundred and sixty-five subjects receiving MHD between July 2015 and September 2016 in 11 hemodialysis centers in Guizhou province were enrolled in this cross-sectional study. Bioelectrical impedance analysis was used to measure RMR and body composition, such as lean body mass, fat mass and body cell mass (BCM). Baseline characteristics, routine blood test indexes and biochemical data of hemodialysis patients were collected. The level of RMR and body composition in hemodialysis patients was compared by gender grouping. Then the patients were divided into four groups according to the cutoff value of RMR quartile. Spearman correlation analysis and multiple linear regression analysis were used to analyze the relationships between RMR and clinical related factors. Results: The average age of MHD patients was (54.96±15.78) years and the duriation of dialysis was (42.3±9.0) months. The level of RMR in male patients (474 cases, 61.96%) was significantly higher than that in female patients [1 591(1 444, 1 764) kcal/d vs 1 226 (1 104, 1 354) kcal/d, P <0.001]. However, this significant difference of RMR between different genders disappeared after adjusting for lean body mass ( P =0.193). Multiple linear regression analysis showed that RMR was positively correlated with body surface area (β=0.817) and lactate dehydrogenase (LDH) (β=0.198), and negatively correlated with age (β=-0.141), all P <0.05. Conclusion: RMR levels in patients with maintenance hemodialysis are associated with lactate dehydrogenase level, which may become a new index to evaluate energy consumption.
NASA Astrophysics Data System (ADS)
Muzasti, R. A.; Lubis, H. R.
2018-03-01
Phase angle, a parameter by Bioelectrical Impedance Analysis, can detect body composition changes, so it can be used as a prognostic indicator in some chronic conditions. This study was for determining the relationship between PhA and hemodiálisis frequency with the survival of chronic hemodiálisis patients. This longitudinal retrospective study involved 173 chronic hemodiálisis patients at Rasyida Renal Hospital. The Kaplan-Meier method is used to determine the survival. Cox proportional hazard analysis is used to determine which variables significantly increase mortality. During the study period, 89 patients underwent hemodiálysis 3x a week (4 hours/session), and 84 patients underwent HD 2x a week (5 hours/session). Demographic and clinical characteristics in both groups were similar. There was no difference in PhA value in groups of 3x a week and group 2x a week (4.02 ± 1.13 vs 4.25 ± 1.12). Patients with twice a week hemodiálisis had a shorter survival than the 3x week group (35.14 ± 2.76 vs 38.62 ± 3.03) although it was not statistically significant (p = 0.126).
Nutritional support and growth in thalassaemia major
Fuchs, G; Tienboon, P; Khaled, M; Nimsakul, S; Linpisarn, S; Faruque, A; Yutrabootr, Y; Dewier, M; Suskind, R
1997-01-01
Accepted 30 January 1997 Twelve thalassaemic children under 3 years of age received intensive nutritional support for one month and were discharged on a prescribed diet of locally available foods. Anthropometry, bioelectrical impedance analysis and dietary intake were longitudinally assessed. Mean energy intake was 20% greater than the recommended daily allowance during nutritional supplementation as compared with below the recommended daily allowance before and after the period of nutritional support. Weight, but not height, significantly increased during the support period and was due to increases in both fat free mass and fat mass. Body weight, fat free mass and fat mass declined in line with the reduced intake upon return home; however, height velocity accelerated and exceeded normal through the fourth month before resuming a below normal rate. It can be concluded that (1) nutritional stunting as the result of reduced nutrient intake is an important cause of growth failure in young children with thalassaemia and is responsive to nutritional support, (2) the deficit in height velocity was due to retarded truncal height growth, and (3) the bioelectrical impedance analysis method is suitable for body composition analysis of thalassaemic children. PMID:9245848
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schols, A.M.; Wouters, E.F.; Soeters, P.B.
1991-02-01
Body composition is an important measure of nutritional status in patients with chronic obstructive pulmonary disease (COPD). We generated a regression model for bioelectrical impedance (BI) by using deuterium dilution (2H2O) as a reference method in 32 COPD patients, aged 63 +/- 9 y (mean +/- SD), in stable pulmonary and cardiac condition. Height squared divided by resistance (Ht2/Res) correlated well with total body water (TBW) as measured by 2H2O (r = 0.93, P less than 0.001, SEE = 1.9 L). The best-fitting regression equation to predict TBW comprised Ht2/Res and body weight (r2 = 0.89, SEE = 1.8 L,more » P less than 0.001). BI-predicted TBW was used to estimate BI-fat-free mass (FFM) that was compared with skinfold-thickness-based FFM predictions (Anthr-FFM). Relative to BI-FFM a significant overestimation of 4.4 +/- 0.8 kg was found by Anthr-FFM. Our results suggest that BI is a useful measure of body composition in patients with severe COPD.« less
[Wearable Automatic External Defibrillators].
Luo, Huajie; Luo, Zhangyuan; Jin, Xun; Zhang, Leilei; Wang, Changjin; Zhang, Wenzan; Tu, Quan
2015-11-01
Defibrillation is the most effective method of treating ventricular fibrillation(VF), this paper introduces wearable automatic external defibrillators based on embedded system which includes EGG measurements, bioelectrical impedance measurement, discharge defibrillation module, which can automatic identify VF signal, biphasic exponential waveform defibrillation discharge. After verified by animal tests, the device can realize EGG acquisition and automatic identification. After identifying the ventricular fibrillation signal, it can automatic defibrillate to abort ventricular fibrillation and to realize the cardiac electrical cardioversion.
Bedogni, Giorgio; Grugni, Graziano; Tringali, Gabriella; Agosti, Fiorenza; Sartorio, Alessandro
2015-01-01
Fat-free mass (FFM) is lower in obese subjects with Prader-Willi syndrome (PWS) than in obese subjects without PWS. FFM prediction equations developed in non-PWS subjects may, thus, not work in PWS subjects. To test whether the estimation of FFM from bioelectrical impedance analysis (BIA) in PWS subjects requires population-specific equations. Using dual-energy X-ray absorptiometry, this study measured FFM in 27 PWS and 56 non-PWS obese women and evaluated its association with the impedance index at 50 kHz (ZI50), i.e. the ratio between squared height and whole-body impedance at 50 kHz. At the same level of ZI50, PWS women had a lower FFM than non-PWS women. However, when PWS-specific equations were used, FFM was accurately estimated at the population level. An equation employing a dummy variable coding for PWS status was able to explain 85% of the variance of FFM with a root mean squared error of 3.3 kg in the pooled sample (n = 83). Population-specific equations are needed to estimate FFM from BIA in obese PWS women.
Schäff, C T; Pliquett, U; Tuchscherer, A; Pfuhl, R; Görs, S; Metges, C C; Hammon, H M; Kröger-Koch, C
2017-05-01
Body fatness and degree of body fat mobilization in cows vary enormously during their reproduction cycle and influence energy partitioning and metabolic adaptation. The objective of the study was to test bioelectrical impedance spectroscopy (BIS) as a method for predicting fat depot mass (FDM), in living cows. The FDM is defined as the sum of subcutaneous, omental, mesenteric, retroperitoneal, and carcass fat mass. Bioelectrical impedance spectroscopy is compared with the prediction of FDM from the deuterium oxide (DO) dilution method and from body conformation measurements. Charolais × Holstein Friesian (HF; = 18; 30 d in milk) crossbred cows and 2 HF (lactating and nonlactating) cows were assessed by body conformation measurements, BIS, and the DO dilution method. The BCS of cows was a mean of 3.68 (SE 0.64). For the DO dilution method, a bolus of 0.23 g/kg BW DO (60 atom%) was intravenously injected and deuterium (D) enrichment was analyzed in plasma and whey by stabile isotope mass spectrometry, and total body water content was calculated. Impedance measurement was performed using a 4-electrode interface and time domain-based measurement system consisting of a voltage/current converter for applying current stimulus and an amplifier for monitoring voltage across the sensor electrodes. For the BIS, we used complex impedances over three frequency decades that delivers information on intra- and extracellular water and capacity of cell membranes. Impedance data (resistance of extra- and intracellular space, cell membrane capacity, and phase angle) were extracted 1) by simple curve fit to extract the resistance at direct current and high frequency and 2) by using an electrical equivalent circuit. Cows were slaughtered 7 d after BIS and D enrichment measurements and dissected for the measurement of FDM. Multiple linear regression analyses were performed to predict FDM based on data obtained from body conformation measurements, BIS, and D enrichment, and applied methods were evaluated by cross-validation. The FDM varied widely between cows and was correlated to D enrichment in plasma ( = 0.91, < 0.05). Prediction of FDM by body size measurements was less precise ( = 0.84), but FDM prediction was more accurate using D enrichment in plasma ( = 0.90) and BIS ( = 0.99) data. Therefore, both BIS and D enrichment analysis resulted in similarly good predictions of FDM in cows, and we conclude that BIS could have the potential to predict FDM in dairy cows from 40 to 380 kg.
Buffa, R; Mereu, R M; Putzu, P F; Floris, G; Marini, E
2010-12-01
This paper evaluates the nutritional status in patients with mild-moderate and severe Alzheimer's disease (AD) by bioelectrical impedance vector analysis (BIVA). Cross-sectional study. Alzheimer Center, SS. Trinita Hospital, Cagliari, and "Monsignor Angioni" Nursing Home, Quartu Sant'Elena (Cagliari, Italy). 83 free-living patients with mild-moderate Alzheimer's disease (29 men, 54 women), 9 institutionalized women in the severe stage; 468 age-matched controls (202 men, 266 women). Mini Nutritional Assessment (MNA), anthropometric (height, weight, BMI), bioelectrical (R, Xc) and biochemical variables (serum albumin) were assessed. Bioelectrical characteristics were significantly different in the patients with mild-moderate AD with respect to controls, indicating low body cell mass (men, T2= 12.8; women, T2=34.9; p < 0.01). Women with severe AD showed low body cell mass and dehydration with respect to patients with mild-moderate AD (T2=17.1; p < 0.01). The phase angle, R/H and Z/H were significantly correlated (p < 0.05) with MNA (phase: r = 0.31; R/H: r =-0.37; Z/H: r =-0.37) and albumin (phase: r=0.47; R/H: r=-0.36; Z/H: r=-0.36). Alzheimer's disease is characterized by a tendency to malnutrition, present even in the mild-moderate stages, and a tendency to dehydration that appears in the severe stage. The BIVA technique is a promising tool for the screening and monitoring of nutrition and hydration status in Alzheimer's disease.
Gonzalez, Maria Cristina; Heymsfield, Steven B
2017-04-01
As reference methods are not available for identifying low skeletal muscle mass in clinical practice, the European Group on Sarcopenia in Older People the Asian Working Group for Sarcopenia and the International Consensus for Cancer Cachexia guidelines accept bioelectrical impedance analysis (BIA) as an option for sarcopenia and cachexia assessment. Using different BIA equations, several components that represent 'muscularity' can be assessed. Total skeletal muscle mass or appendicular skeletal muscle mass normalized in relation to height (skeletal muscle mass index or appendicular skeletal muscle index, respectively) is the most common term used in the consensus. These terms are similar, but they should not be used as synonymous. Both terms can be used to define sarcopenia, but adequate equations and cut-off values should be used according to the studied population. However, there is a disagreement between the sarcopenia definition assessed by using BIA from the European Group on Sarcopenia in Older People and Cachexia Consensus, and this can lead to an overestimation of sarcopenia and, consequently, cachexia. An effort should be made to standardize the terminology employed by the Societies to define low muscularity and sarcopenia by using BIA. Future validation studies may show the need for specific cut-off values for each population using this method. © 2017 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.
Wang, Hui; Hai, Shan; Cao, Li; Zhou, Jianghua; Liu, Ping; Dong, Bi-Rong
2016-12-28
The aim of the present study was to validate the usefulness of the new octapolar multifrequency bioelectrical impedance analysis (BIA) for assessment of appendicular skeletal muscle mass (ASM) by comparing it with that of dual-energy X-ray absorptiometry (DXA) and to investigate the prevalence of sarcopenia in Chinese community-dwelling elderly according to Asian Working Group for Sarcopenia (AWGS) definition. A cross-sectional study was conducted in communities of Chengdu, China. A total of 944 community-dwelling elderly adults aged ≥60 years were included. ASM was measured by using DXA as a criterion method to validate a standing eight-electrode multifrequency BIA (InBody 720), followed by a further estimation of the prevalence of sarcopenia according the AWGS definition. In the Bland-Altman analysis, no significant difference was found between DXA and BIA based on the ASM measurements. The prevalence of AWGS-defined sarcopenia was 12.5% in the elderly women and 8.2% in the elderly men. BIA is suitable for body composition monitoring (ASM) in elderly Chinese as a fast, noninvasive, and convenient method; therefore, it may be a better choice in large epidemiological studies in the Chinese population. The prevalence of AWGS-defined sarcopenia was approximately 10.4% and increased with age in the Chinese community-dwelling elderly in this study.
ERIC Educational Resources Information Center
Mooney, Angela; Kelsey, Laurel; Fellingham, Gilbert W.; George, James D.; Hager, Ron L.; Myrer, J. William; Vehrs, Pat R.
2011-01-01
To determine the validity and reliability of percent body fat estimates in 177 boys and 154 girls between 12-17 years of age, percent body fat was assessed once using dual-energy X-ray absorptiometry and twice using the sum of two skinfolds and three bioelectrical impedance analysis devices. The assessments were repeated on 79 participants on a…
2013-01-01
Background This study aims to improve accuracy of Bioelectrical Impedance Analysis (BIA) prediction equations for estimating fat free mass (FFM) of the elderly by using non-linear Back Propagation Artificial Neural Network (BP-ANN) model and to compare the predictive accuracy with the linear regression model by using energy dual X-ray absorptiometry (DXA) as reference method. Methods A total of 88 Taiwanese elderly adults were recruited in this study as subjects. Linear regression equations and BP-ANN prediction equation were developed using impedances and other anthropometrics for predicting the reference FFM measured by DXA (FFMDXA) in 36 male and 26 female Taiwanese elderly adults. The FFM estimated by BIA prediction equations using traditional linear regression model (FFMLR) and BP-ANN model (FFMANN) were compared to the FFMDXA. The measuring results of an additional 26 elderly adults were used to validate than accuracy of the predictive models. Results The results showed the significant predictors were impedance, gender, age, height and weight in developed FFMLR linear model (LR) for predicting FFM (coefficient of determination, r2 = 0.940; standard error of estimate (SEE) = 2.729 kg; root mean square error (RMSE) = 2.571kg, P < 0.001). The above predictors were set as the variables of the input layer by using five neurons in the BP-ANN model (r2 = 0.987 with a SD = 1.192 kg and relatively lower RMSE = 1.183 kg), which had greater (improved) accuracy for estimating FFM when compared with linear model. The results showed a better agreement existed between FFMANN and FFMDXA than that between FFMLR and FFMDXA. Conclusion When compared the performance of developed prediction equations for estimating reference FFMDXA, the linear model has lower r2 with a larger SD in predictive results than that of BP-ANN model, which indicated ANN model is more suitable for estimating FFM. PMID:23388042
Kafri, Mohannad W.; Myint, Phyo Kyaw; Doherty, Danielle; Wilson, Alexander Hugh; Potter, John F.; Hooper, Lee
2013-01-01
Background Non-invasive methods for detecting water-loss dehydration following acute stroke would be clinically useful. We evaluated the diagnostic accuracy of multi-frequency bioelectrical impedance analysis (MF-BIA) against reference standards serum osmolality and osmolarity. Material/Methods Patients admitted to an acute stroke unit were recruited. Blood samples for electrolytes and osmolality were taken within 20 minutes of MF-BIA. Total body water (TBW%), intracellular (ICW%) and extracellular water (ECW%), as percentages of total body weight, were calculated by MF-BIA equipment and from impedance measures using published equations for older people. These were compared to hydration status (based on serum osmolality and calculated osmolarity). The most promising Receiver Operating Characteristics curves were plotted. Results 27 stroke patients were recruited (mean age 71.3, SD10.7). Only a TBW% cut-off at 46% was consistent with current dehydration (serum osmolality >300 mOsm/kg) and TBW% at 47% impending dehydration (calculated osmolarity ≥295–300 mOsm/L) with sensitivity and specificity both >60%. Even here diagnostic accuracy of MF-BIA was poor, a third of those with dehydration were wrongly classified as hydrated and a third classified as dehydrated were well hydrated. Secondary analyses assessing diagnostic accuracy of TBW% for men and women separately, and using TBW as a percentage of lean body mass showed some promise, but did not provide diagnostically accurate measures across the population. Conclusions MF-BIA appears ineffective at diagnosing water-loss dehydration after stroke and cannot be recommended as a test for dehydration, but separating assessment by sex, and using TBW as a percentage of lean body weight may warrant further investigation. PMID:23839255
Bioelectrical Impedance Vector Analysis and Muscular Fitness in Healthy Men
Rodríguez-Rodríguez, Fernando; Cristi-Montero, Carlos; González-Ruíz, Katherine; Correa-Bautista, Jorge Enrique; Ramírez-Vélez, Robinson
2016-01-01
Muscle strength can define the general muscular fitness (MF) measurable through hand-grip strength (HG), which is a factor that relates to the health of people of different ages. In this study we evaluated the muscle strength together with a bioimpedance electric analysis in 223 healthy Colombian adult subjects. The bioelectrical impedance vector analysis (BIVA) was conducted to determine the resistance (R), reactance (Xc) and phase angle (PhA). We classified the subjects into three groups (for tertiles), obtaining lower values of R and Xc in subjects with lower HG, plus a high correlation between PhA and HG. An increase in the level of PhA is associated with a high level of MF in a sample of healthy Latin American adult men. The BIVA’s parameters and PhA are a potentially effective preventive measure to be integrated into routine screening in the clinical setting. PMID:27384579
Abrahamsen, B; Hansen, T B; Høgsberg, I M; Pedersen, F B; Beck-Nielsen, H
1996-01-01
Dual X-ray absorptiometry (DXA) performs noninvasive assessment of bone and soft tissue with high precision. However, soft tissue algorithms assume that 73.2% of the lean body mass is water, a potential source of error in fluid retention. We evaluated DXA (model QDR-2000; Hologic Inc, Waltham, MA), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined by the reduction in gravimetric weight (r = 0.975, P < 0.0001; SEE: 233 g), whereas BIA was considerably less accurate in assessing FFM reductions (r = 0.66, P < 0.01; SEE: 757 g). Lumbar bone mineral density (BMD) was unaffected by dialysis, as were whole-body fat and BMD. Whole-body bone mineral content, however, was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis is on repeated measurements.
Tyrrell, V J; Richards, G; Hofman, P; Gillies, G F; Robinson, E; Cutfield, W S
2001-02-01
To determine the accuracy of foot-to-foot bioelectrical impedance analysis (BIA) and anthropometric indices as measures of body composition in children. Comparison of foot-to-foot BIA and anthropometry to dual-energy X-ray absorptiometry (DEXA)-derived body composition in a multi-ethnic group of children. : Eighty-two European, NZ Maori and Pacific Island children aged 4.9-10.9 y. DEXA body composition, foot-to-foot bioelectrical impedance, height, weight, hip and waist measurements. Using a BIA prediction equation derived from our study population we found a high correlation between DEXA and BIA in the estimation of fat-free mass (FFM), fat mass (FM) and percentage body fat (PBF) (r=0.98, 0.98 and 0.94, respectively). BIA-FFM underestimated DEXA-FFM by a mean of 0.75 kg, BIA-FM overestimated DEXA-FM by a mean of 1.02 kg and BIA-PBF overestimated DEXA-PBF by a mean of 2.53%. The correlation between six anthropometric indices (body mass index (BMI), ponderal index, Chinn's weight-for-height index, BMI standard deviation score, weight-for-length index and Cole's weight-for-height index) and DEXA were also examined. The correlation of these indices with PBF was remarkably similar (r=0.85-0.87), more variable with FM (r=0.77-0.94) and poor with FFM (r=0.41-0.75). BIA correlated better than anthropometric indices in the estimation of FFM, FM and PBF. Foot-to-foot BIA is an accurate technique in the measurement of body composition.
Bell, Kristie L; Boyd, Roslyn N; Walker, Jacqueline L; Stevenson, Richard D; Davies, Peter S W
2013-08-01
Body composition assessment is an essential component of nutritional evaluation in children with cerebral palsy. This study aimed to validate bioelectrical impedance to estimate total body water in young children with cerebral palsy and determine best electrode placement in unilateral impairment. 55 young children with cerebral palsy across all functional ability levels were included. Height/length was measured or estimated from knee height. Total body water was estimated using a Bodystat 1500MDD and three equations, and measured using the gold standard, deuterium dilution technique. Comparisons were made using Bland Altman analysis. For children with bilateral impairment, the Fjeld equation estimated total body water with the least bias (limits of agreement): 0.0 L (-1.4 L to 1.5 L); the Pencharz equation produced the greatest: 2.7 L (0.6 L-4.8 L). For children with unilateral impairment, differences between measured and estimated total body water were lowest on the unimpaired side using the Fjeld equation 0.1 L (-1.5 L to 1.6 L)) and greatest for the Pencharz equation. The ability of bioelectrical impedance to estimate total body water depends on the equation chosen. The Fjeld equation was the most accurate for the group, however, individual results varied by up to 18%. A population specific equation was developed and may enhance the accuracy of estimates. Australian New Zealand Clinical Trials Registry (ANZCTR) number: ACTRN12611000616976. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Antoni, Giorgia; Marini, Elisabetta; Curreli, Nicoletta; Tuveri, Valerio; Comandini, Ornella; Cabras, Stefano; Gabba, Silvia; Madeddu, Clelia; Crisafulli, Antonio; Rinaldi, Andrea C
2017-01-01
The aim of this study was to determine the energy expenditure of a group of cavers of both genders and different ages and experience during a 10 hour subterranean exploration, using portable metabolimeters. The impact of caving activity on body composition and hydration were also assessed through bioelectrical impedance, and nutritional habits of cavers surveyed. During cave activity, measured total energy expenditure (TEE) was in the range 225-287 kcal/h for women-men (MET = 4.1), respectively; subjects had an energy intake from food in the range 1000-1200 kcal, thus inadequate to restore lost calories. Bayesian statistical analysis estimated the effect of predictive variables on TEE, revealing that experienced subjects had a 5% lower TEE than the less skilled ones and that women required a comparatively larger energy expenditure than men to perform the same task. BIVA (bioelectrical impedance vector analysis) showed that subjects were within the range of normal hydration before and after cave activity, but bioelectrical changes indicated a reduction of extracellular water in men, which might result in hypo-osmolal dehydration in the case of prolonged underground exercise. All these facts should be considered when planning cave explorations, preparing training programs for subjects practising caving, and optimizing a diet for cavers. Further, information gathered through this study could be of value to reduce accidents in caves related to increase in fatigue.
Kafri, Mohannad W; Myint, Phyo Kway; Doherty, Danielle; Wilson, Alexander Hugh; Potter, John F; Hooper, Lee
2013-07-10
Non-invasive methods for detecting water-loss dehydration following acute stroke would be clinically useful. We evaluated the diagnostic accuracy of multi-frequency bioelectrical impedance analysis (MF-BIA) against reference standards serum osmolality and osmolarity. Patients admitted to an acute stroke unit were recruited. Blood samples for electrolytes and osmolality were taken within 20 minutes of MF-BIA. Total body water (TBW%), intracellular (ICW%) and extracellular water (ECW%), as percentages of total body weight, were calculated by MF-BIA equipment and from impedance measures using published equations for older people. These were compared to hydration status (based on serum osmolality and calculated osmolarity). The most promising Receiver Operating Characteristics curves were plotted. 27 stroke patients were recruited (mean age 71.3, SD10.7). Only a TBW% cut-off at 46% was consistent with current dehydration (serum osmolality >300 mOsm/kg) and TBW% at 47% impending dehydration (calculated osmolarity ≥295-300 mOsm/L) with sensitivity and specificity both >60%. Even here diagnostic accuracy of MF-BIA was poor, a third of those with dehydration were wrongly classified as hydrated and a third classified as dehydrated were well hydrated. Secondary analyses assessing diagnostic accuracy of TBW% for men and women separately, and using TBW as a percentage of lean body mass showed some promise, but did not provide diagnostically accurate measures across the population. MF-BIA appears ineffective at diagnosing water-loss dehydration after stroke and cannot be recommended as a test for dehydration, but separating assessment by sex, and using TBW as a percentage of lean body weight may warrant further investigation.
Wang, Lin; Hui, Stanley Sai-chuen; Wong, Stephen Heung-sang
2014-01-01
Background The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. Material/Methods A total of 255 healthy Chinese children and adolescents aged 9 to 19 years old (127 males and 128 females) from Tianjin, China, participated in the BIA measurement at 50 kHz between the hand and the foot. The criterion measure of FFM was also employed using dual-energy X-ray absorptiometry (DEXA). FFM estimated from 24 published BIA equations was cross-validated against the criterion measure from DEXA. Multiple linear regression was conducted to examine alternative BIA equation for the studied population. Results FFM estimated from the 24 published BIA equations yielded high correlations with the directly measured FFM from DEXA. However, none of the 24 equations was statistically equivalent with the DEXA-measured FFM. Using multiple linear regression and cross-validation against DEXA measurement, an alternative prediction equation was determined as follows: FFM (kg)=1.613+0.742×height (cm)2/impedance (Ω)+0.151×body weight (kg); R2=0.95; SEE=2.45kg; CV=6.5, 93.7% of the residuals of all the participants fell within the 95% limits of agreement. Conclusions BIA was highly correlated with FFM in Chinese children and adolescents. When the new developed BIA equations are applied, BIA can provide a practical and valid measurement of body composition in Chinese children and adolescents. PMID:25398209
Validation of a portable bioelectrical impedance analyzer for the assessment of body composition.
Karelis, Antony D; Chamberland, Gabriel; Aubertin-Leheudre, Mylène; Duval, Christian
2013-01-01
One of the major challenges in field research has been the difficulty to adequately measure body composition, such as % body fat and fat-free mass (FFM). Therefore, the purpose of the present study was to investigate the convergent validity of the portable bioelectrical impedance body composition analyzer, the Inbody 230, with dual X-ray absorptiometry (DXA) (General Electric Lunar Prodigy). The study population consisted of 145 men and women (age, 44.6 ± 20 years; BMI, 24.5 ± 3.8 kg·m(-2)). We measured body composition (fat mass, % body fat, total FFM, trunk FFM, and appendicular FFM) using DXA and the Inbody 230. Results show strong significant correlations between both methods for fat mass, % body fat, total FFM, and trunk FFM (r = 0.94-0.99). Furthermore, we showed a modest significant correlation between both methods for appendicular FFM (r = 0.63). Finally, as shown by Bland-Altman analysis, no significant biases were observed between Inbody 230 and DXA for fat mass, % body fat, and total FFM. However, trunk and appendicular FFM were shown to have significant biases between the Inbody 230 and DXA. In conclusion, the present study indicated that the portable Inbody 230 may be an acceptable device to measure fat mass, % body fat, and total FFM (except for women) in healthy adults. In addition, there appears to be a systematic bias for the estimation of trunk and appendicular FFM with the Inbody 230 in men and women.
Smartphone-Based Bioelectrical Impedance Analysis Devices for Daily Obesity Management
Choi, Ahyoung; Kim, Justin Younghyun; Jo, Seongwook; Jee, Jae Hwan; Heymsfield, Steven B.; Bhagat, Yusuf A.; Kim, Insoo; Cho, Jaegeol
2015-01-01
Current bioelectric impedance analysis (BIA) systems are often large, cumbersome devices which require strict electrode placement on the user, thus inhibiting mobile capabilities. In this work, we developed a handheld BIA device that measures impedance from multiple frequencies (5 kHz~200 kHz) with four contact electrodes and evaluated the BIA device against standard body composition analysis systems: a dual-energy X-ray absorptiometry (DXA) system (GE Lunar Prodigy, GE Healthcare, Buckinghamshire, UK) and a whole-body BIA system (InBody S10, InBody, Co. Ltd, Seoul, Korea). In the study, 568 healthy participants, varying widely in body mass index, age, and gender, were recruited at two research centers: the Samsung Medical Center (SMC) in South Korea and the Pennington Biomedical Research Center (PBRC) in the United States. From the measured impedance data, we analyzed individual body fat and skeletal muscle mass by applying linear regression analysis against target reference data. Results indicated strong correlations of impedance measurements between the prototype pathways and corresponding InBody S10 electrical pathways (R = 0.93, p < 0.0001). Additionally, body fat estimates from DXA did not yield significant differences (p > 0.728 (paired t-test), DXA mean body fat 29.45 ± 10.77 kg, estimated body fat 29.52 ± 12.53 kg). Thus, this portable BIA system shows a promising ability to estimate an individual’s body composition that is comparable to large stationary BIA systems. PMID:26364636
Estimation of maximal oxygen uptake by bioelectrical impedance analysis.
Stahn, Alexander; Terblanche, Elmarie; Grunert, Sven; Strobel, Günther
2006-02-01
Previous non-exercise models for the prediction of maximal oxygen uptake VO(2max) have failed to accurately discriminate cardiorespiratory fitness within large cohorts. The aim of the present study was to evaluate the feasibility of a completely indirect method for predicting VO(2max) that was based on bioelectrical impedance analysis (BIA) in 66 young, healthy fit men and women. Multiple, stepwise regression analysis was used to determine the usefulness of BIA and additional covariates to estimate VO(2max) (ml min(-1)). BIA was highly correlated to VO(2max) (r = 0.914; P < 0.001) and entered the regression equation first. The inclusion of gender and a physical activity rating further improved the model which accounted for 88% of the variance in VO(2max) and resulted in a relative standard error of the estimate (SEE) of 7.2%. Substantial agreement between the methods was confirmed by the fact that nearly all the differences were within +/-2 SD. Furthermore, in contrast to previously published non-exercise models, no trend of a reduction in prediction accuracy with increasing VO(2max) values was apparent. It was concluded that a non-exercise model based on BIA might be a rapid and useful technique to estimate VO(2max), when a direct test does not seem feasible. However, though the present results are useful to determine the viability of the method, further refinement of the BIA approach and its validation in a large, diverse population is needed before it can be applied to the clinical and epidemiological settings.
Chen, Kuen-Tsann; Chen, Yu-Yawn; Wang, Chia-Wei; Chuang, Chih-Lin; Chiang, Li-Ming; Lai, Chung-Liang; Lu, Hsueh-Kuan; Dwyer, Gregory B; Chao, Shu-Ping; Shih, Ming-Kuei; Hsieh, Kuen-Chang
2016-01-01
Bioelectrical impedance analysis (BIA) is a common method for assessing body composition in research and clinical trials. BIA is convenient but when compared with other reference methods, the results have been inconclusive. The level of obesity degree in subjects is considered to be an important factor affecting the accuracy of the measurements. A total of 711 participants were recruited in Taiwan and were sub-grouped by gender and levels of adiposity. Regression analysis and Bland-Altman analysis were used to evaluate the agreement of the measured body fat percentage (BF%) between BIA and DXA. The BF% measured by the DXA and BIA methods (Tanita BC-418) were expressed as BF%DXA and BF%BIA8, respectively. A one-way ANOVA was used to test the differences in BF% measurements by gender and levels of adiposity. The estimated BF%BIA8 and BF%DXA in the all subjects, male and female groups were all highly correlated (r = 0.934, 0.901, 0.916, all P< 0.001). The average estimated BF%BIA8 (22.54 ± 9.48%) was significantly lower than the average BF%DXA (26.26 ± 11.18%). The BF%BIA8 was overestimated in the male subgroup (BF%DXA< 15%), compared to BF%DXA by 0.45%, respectively. In the other subgroups, the BF%BIA8 values were all underestimated. Standing BIA estimating body fat percentage in Chinese participants have a high correlation, but underestimated on normal and high obesity degree in both male and female subjects.
Utter, Alan C; Lambeth, Pamela G
2010-02-01
To evaluate the accuracy of multifrequency bioelectrical impedance analysis (MFBIA) in assessing fat-free mass (FFM) in comparison with hydrostatic weighing (HW) and skinfolds (SK) in high school wrestlers in a hydrated state. Body composition was determined by MFBIA, HW, and three-site SK in 72 high school wrestlers (mean +/- SD; age = 15.3 +/- 1.4 yr, height = 1.71 +/- 0.08 m, body mass = 67.3 +/- 13.4 kg). Hydration state was quantified by evaluating urine specific gravity. There were no significant differences for estimated FFM between MFBIA (57.2 +/- 9.5 kg) and HW (57.0 +/- 10.1 kg) or SK (56.4 +/- 8.8 kg). The SEE for FFM with HW as the reference method were 2.73 kg for MFBIA and 2.66 kg for SK. Correlations were found for FFM between HW and MFBIA (r = 0.96, P < 0.001) and between HW and SK (r = 0.97, P < 0.001). A systematic bias was found for MFBIA because the difference between MFBIA and HW correlated with the FFM average of the two methods (r = -0.22, P < 0.001). A bias was also seen between SK and HW and correlated with the FFM average (r = -0.47, P < 0.001). This study demonstrates that MFBIA provides similar estimates of FFM when compared with HW in a heterogeneous high school wrestling population during a hydrated state. MFBIA is an attractive assessment tool, easy to use, and may be considered as an alternative field-based method of estimating the FFM of high school wrestlers.
Chen, Kuen-Tsann; Chen, Yu-Yawn; Wang, Chia-Wei; Chuang, Chih-Lin; Chiang, Li-Ming; Lai, Chung-Liang; Lu, Hsueh-Kuan; Dwyer, Gregory B.; Chao, Shu-Ping; Shih, Ming-Kuei; Hsieh, Kuen-Chang
2016-01-01
Bioelectrical impedance analysis (BIA) is a common method for assessing body composition in research and clinical trials. BIA is convenient but when compared with other reference methods, the results have been inconclusive. The level of obesity degree in subjects is considered to be an important factor affecting the accuracy of the measurements. A total of 711 participants were recruited in Taiwan and were sub-grouped by gender and levels of adiposity. Regression analysis and Bland-Altman analysis were used to evaluate the agreement of the measured body fat percentage (BF%) between BIA and DXA. The BF% measured by the DXA and BIA methods (Tanita BC-418) were expressed as BF%DXA and BF%BIA8, respectively. A one-way ANOVA was used to test the differences in BF% measurements by gender and levels of adiposity. The estimated BF%BIA8 and BF%DXA in the all subjects, male and female groups were all highly correlated (r = 0.934, 0.901, 0.916, all P< 0.001). The average estimated BF%BIA8 (22.54 ± 9.48%) was significantly lower than the average BF%DXA (26.26 ± 11.18%). The BF%BIA8 was overestimated in the male subgroup (BF%DXA< 15%), compared to BF%DXA by 0.45%, respectively. In the other subgroups, the BF%BIA8 values were all underestimated. Standing BIA estimating body fat percentage in Chinese participants have a high correlation, but underestimated on normal and high obesity degree in both male and female subjects. PMID:27467065
Dibble, Kimberly L.; Yard, Micheal D.; Ward, David L.; Yackulic, Charles B.
2017-01-01
Bioelectrical impedance analysis (BIA) is a nonlethal tool with which to estimate the physiological condition of animals that has potential value in research on endangered species. However, the effectiveness of BIA varies by species, the methodology continues to be refined, and incidental mortality rates are unknown. Under laboratory conditions we tested the value of using BIA in addition to morphological measurements such as total length and wet mass to estimate proximate composition (lipid, protein, ash, water, dry mass, energy density) in the endangered Humpback Chub Gila cypha and Bonytail G. elegans and the species of concern Roundtail Chub G. robusta and conducted separate trials to estimate the mortality rates of these sensitive species. Although Humpback and Roundtail Chub exhibited no or low mortality in response to taking BIA measurements versus handling for length and wet-mass measurements, Bonytails exhibited 14% and 47% mortality in the BIA and handling experiments, respectively, indicating that survival following stress is species specific. Derived BIA measurements were included in the best models for most proximate components; however, the added value of BIA as a predictor was marginal except in the absence of accurate wet-mass data. Bioelectrical impedance analysis improved the R2 of the best percentage-based models by no more than 4% relative to models based on morphology. Simulated field conditions indicated that BIA models became increasingly better than morphometric models at estimating proximate composition as the observation error around wet-mass measurements increased. However, since the overall proportion of variance explained by percentage-based models was low and BIA was mostly a redundant predictor, we caution against the use of BIA in field applications for these sensitive fish species.
Kudsk, Kenneth A; Munoz-Del-Rio, Alejandro; Busch, Rebecca A; Kight, Cassandra E; Schoeller, Dale A
2017-02-01
Loss of protein mass and lower fat-free mass index (FFMI) are associated with longer length of stay, postsurgical complications, and other poor outcomes in hospitalized patients. Normative data for FFMI of U.S. populations do not exist. This work aims to create a stratified FFMI percentile table for the U.S. population using the large bioelectric impedance analysis data obtained from National Health and Nutrition Examination Surveys (NHANES). Fat-free mass (FFM) was calculated from the NHANES III bioelectric impedance analysis and anthropometric data for males and females ages 12 to >90 years for 3 race/ethnicities (non-Hispanic white, non-Hispanic black, and Mexican American). FFM was normalized by subject height to create an FFMI distribution table for the U.S. Selected percentiles were obtained by age, sex, and race/ethnicity. Data were collapsed by race/ethnicity before and after removing obese and underweight participants to create an FFMI decile table for males and females 12 years and older for the healthy-weight U.S. FFMI increased during adolescent growth but stabilized in the early 20s. The FFMI deciles were similar by race/ethnicity, with age group remaining relatively stable between ages 25 and 80 years. The FFMI deciles for males and females were significantly different. After eliminating the obese and extremely thin, FFMI percentiles remain stable during adult years allowing creation of age- and race/ethnicity-independent decile tables for males and females. These tables allow stratification of individuals for nutrition intervention trials to depict changing nutrition status during medical, surgical, and nutrition interventions.
Marchello, M J; McLennan, J E; Dhuyvetter, D V; Slanger, W D
1999-11-01
Two experiments were performed to develop prediction equations of saleable beef and to validate the prediction equations. In Exp. 1, 50 beef cattle were finished to typical slaughter weights, and multiple linear regression equations were developed to predict kilograms of trimmed boneless, retail product of live cattle, and hot and cold carcasses. A four-terminal bioelectrical impedance analyzer (BIA) was used to measure resistance (Rs) and reactance (Xc) on each animal and processed carcass. The IMPS cuts plus trim were weighed and recorded. Distance between detector terminals (Lg) and carcass temperature (Tp) at time of BIA readings were recorded. Other variables included live weight (BW), hot carcass weight (HCW), cold carcass weight (CCW), and volume (Lg2/Rs). Regression equations for predicting kilograms of saleable product were [11.87 + (.409 x BW) - (.335 x Lg) + (.0518 x volume)] for live (R2 = .80); [-58.83 + (.589 x HCW) - (.846 x Rs) + (1.152 x Xc) + (.142 x Lg) + (2.608 x Tp)] for hot carcass (R2 = .95); and [32.15 + (.633 x CCW) + (.33 x Xc) - (.83 x Lg) + (.677 x volume)] for cold carcass (R2 = .93). In Exp. 2, 27 beef cattle were finished in a manner similar to Exp. 1, and the prediction equations from Exp. 1 were used to predict the saleable product of these animals. The Pearson correlations between actual saleable product and the predictions based on live and cold carcass data were .91 and .95, respectively. The Spearman and Kendall rank correlations were .95 and .83, respectively, for the cold carcass data. These results provide a practical application of bioelectrical impedance for market-based pricing. They complement previous studies that assessed fat-free mass.
Kurinami, Noboru; Sugiyama, Seigo; Morita, Ayami; Yoshida, Akira; Hieshima, Kunio; Miyamoto, Fumio; Kajiwara, Keizo; Jinnouch, Katsunori; Jinnouchi, Tomio; Jinnouchi, Hideaki
2018-05-01
Obesity and ectopic fat accumulation are important conditions of type 2 diabetes mellitus (T2DM). Our aim was to determine whether bioelectrical impedance body composition analysis combined with blood test results could estimate liver ectopic fat accumulation in patients with treatment-naïve T2DM. Subjects were 119 untreated T2DM patients. Computed tomography scans were performed to calculate the liver to spleen attenuation ratio (L/S ratio) as a measure of liver fat accumulation, with excess liver fat accumulation defined as an L/S ratio <1.0. Elementary body composition was measured by bioelectrical impedance analysis using InBody770. The Nagelkerke R 2 test showed that the muscle mass/fat mass ratio (muscle/fat ratio) was the most suitable variable among anthropometric factors and body component indexes for estimating liver fat accumulation. The muscle/fat ratio was significantly correlated with the L/S ratio (ρ = 0.4386, P < 0.0001). Multivariable logistic regression analysis showed that the muscle/fat ratio (odds ratio 0.40, 95% confidence interval 0.22-0.73, P < 0.01) and alanine aminotransferase (odds ratio 1.06, 95% confidence interval 1.02-1.10, P < 0.01) were independently and significantly associated with liver fat accumulation. In receiver operating characteristic curve analysis, the cutoff value of the muscle/fat ratio for excess liver fat accumulation was 2.34. In patients with treatment-naïve T2DM, the muscle/fat ratio and ALT are useful for estimating the presence of excess liver fat accumulation in daily clinical practice. Copyright © 2018. Published by Elsevier B.V.
Fassini, Priscila Giacomo; Nicoletti, Carolina Ferreira; Pfrimer, Karina; Nonino, Carla Barbosa; Marchini, Júlio Sérgio; Ferriolli, Eduardo
2017-08-01
Short bowel syndrome (SBS) represents a serious intestinal absorption disorder. Therefore, patients with SBS may have severe malnutrition and excessive mineral and fluid losses. Once the assessment of nutritional status is important in their follow-up, body composition measurements and especially total body water (TBW) must be repeatedly evaluated for the assessment of changes in hydration and nutritional care. The aim of this study was to investigate if bioelectrical impedance vector analysis (BIVA) is a useful predictor of nutritional and hydration status in SBS patients. In this observational study, 22 participants (12 women), 11 with SBS and 11 gender, age and BMI-matched controls, were evaluated using the bioelectrical impedance measurements (BIA) and BIVA to assess nutritional and hydration status. Participants age was 53 ± 8 y (mean ± SD). Body water, fat mass and lean mass as assessed by BIA did not differ between the two groups. However, BIVA showed important differences between the groups regarding hydration and amount of soft tissue (p < 0.0001 for women and p = 0.0015 for men). The results also evidenced that women's vectors were related to cachexia, while men's vectors were divided into lean and cachexia quadrants. The use of BIVA analysis also evidenced hydration disturbance and losses of soft tissue. BIVA may represent a better predictor of nutritional status for analysis and interpretation of body composition in patients with short bowel syndrome. This trial was registered at ClinicalTrials.gov as NCT02113228. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Hauschild, Daniela Barbieri; Barbosa, Eliana; Moreira, Emilia Addison Machado; Ludwig Neto, Norberto; Platt, Vanessa Borges; Piacentini Filho, Eduardo; Wazlawik, Elisabeth; Moreno, Yara Maria Franco
2016-06-01
(1) To compare nutrition and hydration status between a group of children/adolescents with cystic fibrosis (CFG; n = 46; median age, 8.5 years) and a control group without cystic fibrosis (CG). (2) To examine the association of nutrition and hydration status with lung function in the CFG. A cross-sectional study. Nutrition screening, anthropometric parameters, and bioelectrical impedance analysis (BIA) were assessed. The z scores for body mass index for age, height for age, mid upper arm circumference, triceps and subscapular skinfold thickness, mid upper arm muscle area, resistance/height, and reactance/height were calculated. Bioelectrical impedance vector analysis was conducted. Forced expiratory volume in 1 second <80% was considered lung function impairment. An adjusted logistic regression was applied (P < .05). In the CFG, lung function impairment was observed in 51.1%. All anthropometric parameters were lower, and the mean z-resistance/height and z-reactance/height were higher in the CFG (P < .05) compared with the CG. In the CFG, 43% were severely/mildly dehydrated, while none were in the CG (P = .007). In the CFG, there was an association between high nutrition risk-via nutrition screening (odds ratio [OR], 22.28; P < .05), lower values of anthropometric parameters, higher z-resistance/height (OR, 2.23; P < .05) and z-reactance/height (OR, 1.81; P < .05), and dehydration (OR, 4.94; P < .05)-and lung function impairment. The CFG exhibited a compromised nutrition status assessed by anthropometric and BIA parameters. Nutrition screening, anthropometric and BIA parameters, and hydration status were associated with lung function. © 2016 American Society for Parenteral and Enteral Nutrition.
Torimoto, Kazumasa; Hirayama, Akihide; Samma, Shoji; Yoshida, Katsunori; Fujimoto, Kiyohide; Hirao, Yoshihiko
2009-01-01
Increased nocturnal urinary volume is closely associated with nocturia. We investigated the relationship between nocturnal polyuria and the variation of body fluid distribution during the daytime using bioelectric impedance analysis. A total of 34 men older than 60 years were enrolled in this study. A frequency volume chart was recorded. Nocturnal polyuria was defined as a nocturnal urine volume per 24-hour production of greater than 0.35 (the nocturnal polyuria index). Bioelectric impedance analysis was performed 4 times daily at 8 and 11 a.m., and 5 and 9 p.m. using an InBody S20 body composition analyzer (BioSpace, Seoul, Korea). A significant difference was found in mean +/- SEM 24-hour urine production per fat-free mass between the groups with and without nocturnal polyuria (17.8 +/- 1.4 vs 7.7 +/- 0.9 ml/kg). The increase in fluid in the legs compared with the volume at 8 a.m. was significantly larger at 5 p.m., while there was no difference in the arms or trunk. Nocturnal urine volume significantly correlated with the difference in fluid volume in the legs (r = 0.527, p = 0.0019) and extracellular fluid volume (r = 0.3844, p = 0.0248) between the volumes at 8 a.m. and 9 p.m. Overproduction of urine per fat-free mass leads to nocturnal polyuria. Extracellular fluid accumulates as edema in the legs during the day in patients with nocturnal polyuria. The volume of accumulated extracellular fluid correlates with nocturnal urine volume. We suggest that leg edema is the source of nocturnal urine volume and decreasing edema may cure nocturnal polyuria.
Muscle development in healthy children evaluated by bioelectrical impedance analysis.
Uchiyama, Tomoka; Nakayama, Takahiro; Kuru, Satoshi
2017-02-01
This study aimed to use bioelectrical impedance analysis (BIA) to generate a new muscle density index (MDI), the MDI_BIA, to evaluate muscle development, and to demonstrate the changes that occur in the BIA-based muscle cross-sectional area index (MCAI_BIA) that accompany growth. We also sought to determine the traceability of chronological changes in the MDI_BIA and MCAI_BIA. Healthy children (n=112) aged 8.68±3.16years (0.33-14.00years) underwent bioelectrical impedance (BI) measurements of their upper arms, thighs, and lower legs. The MDI_BIA and MCAI_BIA were calculated, and cross-sectional investigations were conducted into the changes in these indices that accompanied growth. Data collected after 1.10±0.08years from 45 participants determined the traceability of the chronological changes in the MDI_BIA and MCAI_BIA. The MDI_BIA and MCAI_BIA were significantly positively correlated with age and height at all locations (P<0.01). The relationships between the locations and the MDI_BIA and MCAI_BIA differed, indicating that these indices evaluated the muscles from different perspectives. Except for the upper arm MDI_BIA, both indices at all locations regardless of age, showed significant chronological increases after an average period of 1.10years. The MDI_BIA and MCAI_BIA were significantly correlated with age and height in healthy children, and they showed significant chronological increases. Hence, these indices could be used to represent muscle development and muscle mass increases. BIA is non-invasive, convenient, and economical and it may be useful in evaluating muscle development and muscle cross-sectional areas in children. Copyright © 2016 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Svantesson, Ulla; Zander, Martina; Klingberg, Sofia; Slinde, Frode
2008-01-01
Background The aim of this study was to compare body composition results from bioelectrical spectroscopy (BIS) with results from dual energy X-ray absorptiometry (DXA) in a population of male elite athletes. Body composition was assessed using DXA (Lunar Prodigy, GE Lunar Corp., Madison, USA) and BIS (Hydra 4200, Xitron Technologies Inc, San Diego, California, USA) at the same occasion. Agreement between methods was assessed using paired t-tests and agreement-plots. Results Thirty-three male elite athletes (soccer and ice hockey) were included in the study. The results showed that BIS underestimates the proportion of fat mass by 4.6% points in the ice hockey players. In soccer players the BIS resulted in a lower mean fat mass by 1.1% points. Agreement between the methods at the individual level was highly variable. Conclusion Body composition results assessed by BIS in elite athletes should be interpreted with caution, especially in individual subjects. BIS may present values of fat mass that is either higher or lower than fat mass assessed by DXA, independent of true fat content of the individual. PMID:18211680
Wang, Zhenghe; Fu, Lianguo; Yang, Yide; Wang, Shuo; Ma, Jun
2016-05-01
To compare consistency of Body Mineral Content (BMC, kg) assessed by Multi-frequency Bioelectrical Impedance Analysis ( MF-BIA) and Dual Energy X-ray Absorptiometry (DXA) measurement, providing evidence for MF-BIA accurate application in Chinese overweight/obese adults. A total of 1323 overweight/obesity adults aged 22-55 years were recruited voluntarily. All the subjects received the measurement of BMC both using MF-BIA and DXA. To evaluate the agreement of BMC measured by MF-BIA and DXA using interclass correlation coefficients (ICC), then establish correction prediction models. The mean difference of BMC between two methods was significant different with 0, overweight male subgroup was 0.28 kg, and 0.38 kg for obesity male, 0.24 kg for overweight female and 0.36 kg for obesity female, respectively (P < 0.05). The ICC of BMC between MF-BIA and DXA measurement were statistically significant in all subgroups (P < 0.01). The ICC for overweight male subgroup was 0.787, 0.796 for obesity male, 0.741 for overweight female and 0.788 for obesity female, respectively. Correction prediction model: overweight male population: BMC (DXA method) = -0.297 + 1.005 x BMC (MF-BIA method). Obese male population: BMC (DXA method) =0.302 + 0.799 x BMC (MF-BIA method). Overweight female groups: BMC (DXA method) = 0.780 + 0.598 x BMC (MF-BIA method). Obese female group: BMC (DXA method) = 0.755 + 0.597 x BMC (MF-BIA method). Upon examination, correction prediction models were better. Co The correlation and agreement of BMC measured by BIA and DXA are weak in Chinese overweight/obese adults. Therefore, consideration should be given to BMC measured by BIA method in Chinese overweight/obese adults. It should be corrected or adjusted to reduce errors compared with DXA method.
Aleman-Mateo, H; Esparza Romero, J; Macias Morales, N; Salazar, G; Wyatt, J; Valencia, M E
2004-01-01
Air displacement plethysmography with the BOD-POD is a new densitometry technique, and has been found to be an accurate method to measure body composition. The aim of this study was to assess body composition in a group of free living healthy subjects 60 years of age or older from a rural area of Northwest Mexico, and to evaluate body composition by anthropometry and bioelectrical impedance (BIA) using equations reported for other elderly populations. Body composition was evaluated in 21 women and 26 men with the BOD-POD, by anthropometry, and BIA and compared to different equations using the Bland- Altman procedure. Body fat in elderly women and men was 42.7 and 30.2 % respectively. In women, Segal's equation using BIA 1, based on standing height, showed no significant differences with the BOD-POD. There was satisfactory agreement between Segal's equation and BOD-POD. In men similar results was found with Deurenberg's equation using B1A 2 based on recumbent length. Segal's and Deurenberg's equations were accurate and precise for the estimation of body fat in the elderly of this study. The use of these equations could improve the estimation of body composition for similar elderly subjects. Further studies are recommended with a larger size samples to include elderly subjects from other Latin American countries.
Going, S.; Nichols, J.; Loftin, M.; Stewart, D.; Lohman, T.; Tuuri, G.; Ring, K.; Pickrel, J.; Blew, R.; J.Stevens
2007-01-01
Aim Equations for estimating % fat mass (%BF) and fat-free mass (FFM) from bioelectrical impedance analysis (BIA) that work in adolescent girls from different racial/ethnic backgrounds are not available. We investigated whether race/ethnicity influences estimation of body composition in adolescent girls. Principal procedures Prediction equations were developed for estimating FFM and %BF from BIA in 166 girls, 10–15 years old, consisting of 51 Black (B), 45 non-Black Hispanic (H), 55 non-Hispanic White (W) and 15 mixed (M) race/ethnicity girls, using dual energy x-ray absorptiometry (DXA) as the criterion method. Findings Black girls had similar %BF compared to other groups, yet were heavier per unit of height according to body mass index (BMI: kg·m−2) due to significantly greater FFM. BIA resistance index, age, weight and race/ethnicity were all significant predictors of FFM (R2 = 0.92, SEE = 1.81 kg). Standardized regression coefficients showed resistance index (0.63) and weight (0.34) were the most important predictors of FFM. Errors in %BF (~2%) and FFM (~1.0 kg) were greater when race/ethnicity was not included in the equation, particularly in Black girls. We conclude the BIA-composition relationship in adolescent girls is influenced by race, and consequently have developed new BIA equations for adolescent girls for predicting FFM and %BF. PMID:17848976
Antoni, Giorgia; Marini, Elisabetta; Curreli, Nicoletta; Tuveri, Valerio; Comandini, Ornella; Cabras, Stefano; Gabba, Silvia; Madeddu, Clelia; Crisafulli, Antonio
2017-01-01
The aim of this study was to determine the energy expenditure of a group of cavers of both genders and different ages and experience during a 10 hour subterranean exploration, using portable metabolimeters. The impact of caving activity on body composition and hydration were also assessed through bioelectrical impedance, and nutritional habits of cavers surveyed. During cave activity, measured total energy expenditure (TEE) was in the range 225–287 kcal/h for women-men (MET = 4.1), respectively; subjects had an energy intake from food in the range 1000–1200 kcal, thus inadequate to restore lost calories. Bayesian statistical analysis estimated the effect of predictive variables on TEE, revealing that experienced subjects had a 5% lower TEE than the less skilled ones and that women required a comparatively larger energy expenditure than men to perform the same task. BIVA (bioelectrical impedance vector analysis) showed that subjects were within the range of normal hydration before and after cave activity, but bioelectrical changes indicated a reduction of extracellular water in men, which might result in hypo-osmolal dehydration in the case of prolonged underground exercise. All these facts should be considered when planning cave explorations, preparing training programs for subjects practising caving, and optimizing a diet for cavers. Further, information gathered through this study could be of value to reduce accidents in caves related to increase in fatigue. PMID:28158208
NASA Astrophysics Data System (ADS)
Ward, L. C.; Sharpe, K.; Edgar, D.; Finlay, V.; Wood, F.
2013-04-01
Wound healing is a complex process which can be impeded by the presence of accumulated cell fluid or oedema. A simple and convenient method for the assessment of wound oedema would aid improvement in patient care. In this proof of concept study we investigated whether bioelectrical impedance spectroscopy has the potential to provide such a tool. A number of important observations were made. Firstly, the method was highly reproducible and data can be obtained from electrodes located at different positions around the region of interest; important given the highly variable topography of surface wounds, e.g. burns. Secondly, the method was highly sensitive with the potential to detect changes of as little as 20 μl in extracellular fluid. Thirdly the relative changes in R0, R∞ and Ri following sub-cutaneous injections of saline were consistent with redistribution of water from the extracellular to intracellular space and /or removal from the local area as may occur during wound healing.
Shaikh, Saijuddin; Schulze, Kerry J; Kurpad, Anura; Ali, Hasmot; Shamim, Abu Ahmed; Mehra, Sucheta; Wu, Lee S-F; Rashid, Mahbubar; Labrique, Alain B; Christian, Parul; West, Keith P
2013-02-28
Equations for predicting body composition from bioelectrical impedance analysis (BIA) parameters are age-, sex- and population-specific. Currently there are no equations applicable to women of reproductive age in rural South Asia. Hence, we developed equations for estimating total body water (TBW), fat-free mass (FFM) and fat mass in rural Bangladeshi women using BIA, with ²H₂O dilution as the criterion method. Women of reproductive age, participating in a community-based placebo-controlled trial of vitamin A or β-carotene supplementation, were enrolled at 19·7 (SD 9·3) weeks postpartum in a study to measure body composition by ²H₂O dilution and impedance at 50 kHz using multi-frequency BIA (n 147), and resistance at 50 kHz using single-frequency BIA (n 82). TBW (kg) by ²H2O dilution was used to derive prediction equations for body composition from BIA measures. The prediction equation was applied to resistance measures obtained at 13 weeks postpartum in a larger population of postpartum women (n 1020). TBW, FFM and fat were 22·6 (SD 2·7), 30·9 (SD 3·7) and 10·2 (SD 3·8) kg by ²H₂O dilution. Height²/impedance or height²/resistance and weight provided the best estimate of TBW, with adjusted R² 0·78 and 0·76, and with paired absolute differences in TBW of 0·02 (SD 1·33) and 0·00 (SD 1·28) kg, respectively, between BIA and ²H₂O. In the larger sample, values for TBW, FFM and fat were 23·8, 32·5 and 10·3 kg, respectively. BIA can be an important tool for assessing body composition in women of reproductive age in rural South Asia where poor maternal nutrition is common.
Konijn, N P C; van Tuyl, L H D; Bultink, I E M; Lems, W F; Earthman, C P; van Bokhorst-de van der Schueren, M A E
2014-01-01
To examine differences between the assessment of body composition by body mass index (BMI) and bioelectrical impedance analysis (BIA) in patients with rheumatoid arthritis (RA). The body composition of RA patients was assessed during their visit to the outpatient department of a Dutch academic hospital using BMI, fat-free mass index (FFMI), and fat mass index (FMI). FFMI and FMI were determined by single-frequency BIA. Sixty-five consecutive RA patients (83% women, mean age 58 years, median disease duration 7 years) with moderately active disease [mean Disease Activity Score using 28 joint counts (DAS28) = 3.40; mean Rheumatoid Arthritis Disease Activity Index (RADAI) score = 3.49] and moderate disability [mean Health Assessment Questionnaire (HAQ) score = 0.87] were included. Based on BMI, 2% of our study population were underweight, 45% had a healthy body composition, and 54% were overweight or obese. Based on BIA, 18% of the patients showed a low FFMI and 74% had a high or very high FMI. Low FFMI was found in 44% of the women with a normal BMI, and high FMI was found in 40% of the women and 75% of the men with a normal BMI. A high frequency of unfavourable body composition, predominantly reduced FFMI and elevated FMI, was found in a cohort of RA patients with moderately active disease, turning BMI into an unreliable method for assessment of body composition in RA. BIA, however, might be the preferred method to assess FFMI and FMI in RA patients in clinical practice, as it is easy to use and relatively inexpensive.
Validation of bioelectrical impedance analysis in Ethiopian adults with HIV.
Hegelund, Maria H; Wells, Jonathan C; Girma, Tsinuel; Faurholt-Jepsen, Daniel; Zerfu, Dilnesaw; Christensen, Dirk L; Friis, Henrik; Olsen, Mette F
2017-01-01
Bioelectrical impedance analysis (BIA) is an inexpensive, quick and non-invasive method to determine body composition. Equations used in BIA are typically derived in healthy individuals of European descent. BIA is specific to health status and ethnicity and may therefore provide inaccurate results in populations of different ethnic origin and health status. The aim of the present study was to test the validity of BIA in Ethiopian antiretroviral-naive HIV patients. BIA was validated against the 2 H dilution technique by comparing fat-free mass (FFM) measured by the two methods using paired t tests and Bland-Altman plots. BIA was based on single frequency (50 kHz) whole-body measurements. Data were obtained at three health facilities in Jimma Zone, Oromia Region, South-West Ethiopia. Data from 281 HIV-infected participants were available. Two-thirds were female and the mean age was 32·7 (sd 8·6) years. Also, 46 % were underweight with a BMI below 18·5 kg/m 2 . There were no differences in FFM between the methods. Overall, BIA slightly underestimated FFM by 0·1 kg (-0·1, 95 % CI -0·3, 0·2 kg). The Bland-Altman plot indicated acceptable agreement with an upper limit of agreement of 4·5 kg and a lower limit of agreement of -4·6 kg, but with a small correlation between the mean difference and the average FFM. BIA slightly overestimated FFM at low values compared with the 2 H dilution technique, while it slightly underestimated FFM at high values. In conclusion, BIA proved to be valid in this population and may therefore be useful for measuring body composition in routine practice in HIV-infected African individuals.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-06
..., fecundity, bioelectrical impedance analysis (BIA), food habits, and genetic research. The yellowtail... dependent catch data and biological samples. Regulations under the Magnuson-Stevens Fishery Conservation and... Exempted Fishing Permit (EFP) on April 11, 2013, to enable data collection activities that the regulations...
Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; González-Jiménez, Emilio; Triana-Reina, Hector Reynaldo; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline
2018-01-01
To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method. Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland-Altman difference plots. Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P = .001). The paired t-test showed a significant mean difference between these methods for obese men BF% of -0.6 [(SD 1.95; 95% CI = -4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was -0.6 [(SD 2.2; 95% CI = -5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978). Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations. © 2017 Wiley Periodicals, Inc.
Drug and bioactive molecule screening based on a bioelectrical impedance cell culture platform
Ramasamy, Sakthivel; Bennet, Devasier; Kim, Sanghyo
2014-01-01
This review will present a brief discussion on the recent advancements of bioelectrical impedance cell-based biosensors, especially the electric cell-substrate impedance sensing (ECIS) system for screening of various bioactive molecules. The different technical integrations of various chip types, working principles, measurement systems, and applications for drug targeting of molecules in cells are highlighted in this paper. Screening of bioactive molecules based on electric cell-substrate impedance sensing is a trial-and-error process toward the development of therapeutically active agents for drug discovery and therapeutics. In general, bioactive molecule screening can be used to identify active molecular targets for various diseases and toxicity at the cellular level with nanoscale resolution. In the innovation and screening of new drugs or bioactive molecules, the activeness, the efficacy of the compound, and safety in biological systems are the main concerns on which determination of drug candidates is based. Further, drug discovery and screening of compounds are often performed in cell-based test systems in order to reduce costs and save time. Moreover, this system can provide more relevant results in in vivo studies, as well as high-throughput drug screening for various diseases during the early stages of drug discovery. Recently, MEMS technologies and integration with image detection techniques have been employed successfully. These new technologies and their possible ongoing transformations are addressed. Select reports are outlined, and not all the work that has been performed in the field of drug screening and development is covered. PMID:25525360
Siglinsky, E; Buehring, B; Krueger, D; Binkley, N; Yamada, Y
2018-03-25
DXA lean mass measurement for sarcopenia diagnosis is not always possible. Bioelectric impedance spectroscopy (BIS), a portable technology, is a potential alternative to DXA-measured lean mass. This pilot study explores the possibility and proposes an arbitrarily chosen potential cut-point for appendicular intracellular water corrected by height (aICW/ht 2 ). Sarcopenia definitions often include DXA lean mass measurement. However, DXA is not always available. We explored the potential of a less-expensive mobile method, bioelectric impedance spectroscopy (BIS), to assess lean mass for sarcopenia determination. We hypothesized that BIS-measured appendicular intracellular water (aICW/ht 2 ) would correlate with DXA-measured appendicular lean mass (ALM)/ht 2 and with functional parameters. If so, establishing an aICW/ht 2 cut-point in sarcopenia definitions may be feasible. Sixty-one community-dwelling women, mean age 79.9, had BIS and DXA lean mass, grip strength, gait speed, and jumping mechanography assessments. BIS aICW was calculated using limb length and intracellular water resistance. aICW/ht 2 was compared to DXA-measured ALM/ht 2 by linear regression. The European Working Group ALM/ht 2 and an exploratory aICW/ht 2 cut-point were utilized. In this cohort, ALM/ht 2 and aICW/ht 2 were moderately correlated, R 2 = 0.55, p < 0.0001. Lean mass was low in 7 and normal in 44 by BIS and DXA. Those with low aICW/ht 2 had lower grip strength (p = 0.04) and jump power (p = 0.0002) than those with normal aICW/ht 2 and ALM/ht 2 . Subjects with low ALM/ht 2 had lower jump power (p = 0.0006) but were not different in gait speed or grip strength. BIS aICW is correlated with DXA-measured ALM directly, and when height adjusted. An aICW/ht 2 cut-point of 6.5 L/m 2 identified 70% of women with low ALM/ht 2 . Women with low lean mass by DXA and BIS had poorer function measured by jump power. These pilot data support further evaluation of BIS measurement inclusion into sarcopenia definitions.
Smith, D N
1992-01-01
Multiple applied current impedance measurement systems require numbers of current sources which operate simultaneously at the same frequency and within the same phase but at variable amplitudes. Investigations into the performance of some integrated operational transconductance amplifiers as variable current sources are described. Measurements of breakthrough, non-linearity and common-mode output levels for LM13600, NE5517 and CA3280 were carried out. The effects of such errors on the overall performance and stability of multiple current systems when driving floating loads are considered.
Pearman, P; Hunter, G; Hendricks, C; O'Sullivan, P
1989-01-01
This study investigated the effect of dehydration on measurements of body composition by hydrostatic weighing (HW) and bioelectric impedance analysis (BIA). Ten endurance-trained male athletes between the ages of 18 and 42 years performed an endurance training session consisting of running until body weight was reduced by approximately 3%. Body composition was determined prior to exercise and immediately after exercise by HW and BIA techniques. A high correlation existed between pre- and postdehydration for both HW and BIA. Validity coefficients between HW and BIA were moderate (predehydration 0.85 and postdehydration 0.82). In addition, BIA percent fat was 3.5% higher than HW percent fat. The BIA revealed a mean loss of 2.1% fat BIA and only 0.9% fat HW after approximately 45 minutes of exercise. BIA also showed an increase in percent body water (mean = 2.6%) in all 10 subjects after dehydration. There are indications that BIA, with its present equational configuration, is measuring something other than lean body weight. J Orthop Sports Phys Ther 1989;10(11):451-455.
Predicting fat-free mass in children using bioimpedance analysis.
Pietrobelli, A; Andreoli, A; Cervelli, V; Carbonelli, M G; Peroni, D G; De Lorenzo, A
2003-10-01
Body composition assessment is a useful procedure for the study of nutritional status and water distribution. In adults, it is a predictor of morbidity and mortality, since body fatness is associated with risk factors for cardiovascular disease. Bioelectric impedance analysis (BIA) is a simple, safe, and inexpensive method for assessment of body composition both in pediatric and adult subjects. The aim of our study was to validate the impedance index, ZI (H(2)/Z, height in cm(2)/impedance), as a predictor factor of fatfree mass (FFM) and fat mass (FM) in a sample ( n=75) of normal children. Dual-energy X-ray absorptiometry (DXA) was chosen as reference method. Despite some minor bias, DXAis considerably less expensive and easier to administer in pediatric subjects than other established gold standard reference methods for assessing body composition. ZI values were highly correlated with FFM measured with DXA. The following equations were obtained from the regression analysis: (a). male subjects, FFM(DXA)=0.6375 (ZI)+5.9913, r(2)=0.897, p<0.0001; (b). female subjects, FFM(DXA)=0.7597 (ZI)+ 3.5853, r(2)=0.903, p<0.0001. These data support the notion that BIA alone can be used as a surrogate to measure FFM in a pediatric sample.
Viskunova, A A; Kaganov, B S; Sharafetdinov, Kh Kh; Plotnikova, O A; Pogozheva, A V; Vorozhko, I V
2010-01-01
A comprehensive assessment of nutritional status in 73 patients with metabolic syndrome was assessed. The consumption food pattern of the majority of examined patients have had increased energy intake with excessive fat consumption inadequate intake of complex carbohydrates. In patients with type 2 diabetes inadequate compensation of carbohydrate and lipid metabolism was marked. When assessing body composition method bioelectrical impedance analysis increased content of adipose tissue was revealed are positively correlated with insulin and tumor necrosis factor-alpha. According to indirect calorimetry, increase in the level of resting energy expenditure, reducing the rate of oxidation of fat, increase the rate of oxidation of protein and carbohydrates was noted.
Nascimento, Matheus A; Silva, Danilo R P; Ribeiro, Alex S; Pina, Fábio L C; Gerage, Aline M; Gobbo, Luís A; Mayhew, Jerry L; Cyrino, Edilson S
2018-05-23
Nascimento, MA, Silva, DRP, Ribeiro, AS, Pina, FLC, Gerage, AM, Gobbo, LA, Mayhew, JL, and Cyrino, ES. Agreement between bioelectrical impedance and dual-energy x-ray absorptiometry to track changes in fat-free mass after resistance training in older women. J Strength Cond Res XX(X): 000-000, 2018-The aim of our study was to compare the agreement between bioelectrical impedance (BIA) and dual-energy X-ray absorptiometry (DXA) to track changes on fat-free mass (FFM) after a resistance training (RT) program in older women. Forty-three older women (65.2 ± 4.6 years, 59.5 ± 9.2 kg, 156.4 ± 6.0 cm, 24.3 ± 3.3 kg·m) participated in a RT intervention (12 weeks, 8 exercises, 2 sets, 10-15 repetitions, 3 nonconsecutive days per week). Fat-free mass changes were determined by a single-frequency BIA device (EQ1), 6 BIA prediction equations for older women (EQ2, EQ3, EQ4, EQ5, EQ6, and EQ7), and DXA. At pretraining, 3 equations overpredicted, and 3 underpredicted DXA FFM (F = 244.63, p < 0.001), although all equations had high correlations with DXA (r = 0.78-0.83). After training, 4 equations overpredicted and one underpredicted DXA FFM (F = 176.25, p < 0.001). Dual-energy X-ray absorptiometry detected significant gains in FFM (0.65 ± 0.82 kg; p < 0.05), as did EQ3 (0.55 ± 1.69 kg; p < 0.05), and EQ4 (0.61 ± 1.88 kg; p < 0.05), whereas the remaining equations did not indicate significant changes in FFM. Low correlations between FFM and equation change values suggest that single-frequency BIA-derived equations may not provide sufficient accuracy to track changes in FFM after 12 weeks of RT in older women.
Xie, Dawei; Anderson, Amanda H.; Leonard, Mary B.; Reese, Peter P.; Delafontaine, Patrice; Horwitz, Edward; Kallem, Radhakrishna; Navaneethan, Sankar; Ojo, Akinlolu; Porter, Anna C.; Sondheimer, James H.; Sweeney, H. Lee; Townsend, Raymond R.; Feldman, Harold I.
2014-01-01
Background and objectives Previous studies in chronic disease states have demonstrated an association between lower urinary creatinine excretion (UCr) and increased mortality, a finding presumed to reflect the effect of low muscle mass on clinical outcomes. Little is known about the relationship between UCr and other measures of body composition in terms of the ability to predict outcomes of interest. Design, setting, participants, & measurements Using data from the Chronic Renal Insufficiency Cohort (CRIC), the relationship between UCr, fat free mass (FFM) as estimated by bioelectrical impedance analysis, and (in a subpopulation) whole-body dual-energy x-ray absorptiometry assessment of appendicular lean mass were characterized. The associations of UCr and FFM with mortality and ESRD were compared using Cox proportional hazards models. Results A total of 3604 CRIC participants (91% of the full CRIC cohort) with both a baseline UCr and FFM measurement were included; of these, 232 had contemporaneous dual-energy x-ray absorptiometry measurements. Participants were recruited between July 2003 and March 2007. UCr and FFM were modestly correlated (rho=0.50; P<0.001), while FFM and appendicular lean mass were highly correlated (rho=0.91; P<0.001). Higher urinary urea nitrogen, black race, younger age, and lower serum cystatin C level were all significantly associated with higher UCr. Over a median (interquartile range) of 4.2 (3.1–5.0) years of follow-up, 336 (9.3%) participants died and 510 (14.2%) reached ESRD. Lower UCr was associated with death and ESRD even after adjustment for FFM (adjusted hazard ratio for death per 1 SD higher level of UCr, 0.63 [95% confidence interval, 0.56 to 0.72]; adjusted hazard ratio for ESRD per 1 SD higher level of UCr, 0.70 [95% confidence interval, 0.63 to 0.75]). Conclusions Among a cohort of individuals with CKD, lower UCr is associated with death and ESRD independent of FFM as assessed by bioelectrical impedance analysis. PMID:25381342
Prediction of maximal oxygen uptake by bioelectrical impedance analysis in overweight adolescents.
Roberts, M D; Drinkard, B; Ranzenhofer, L M; Salaita, C G; Sebring, N G; Brady, S M; Pinchbeck, C; Hoehl, J; Yanoff, L B; Savastano, D M; Han, J C; Yanovski, J A
2009-09-01
Maximal oxygen uptake (VO(2max)), the gold standard for measurement of cardiorespiratory fitness, is frequently difficult to assess in overweight individuals due to physical limitations. Reactance and resistance measures obtained from bioelectrical impedance analysis (BIA) have been suggested as easily obtainable predictors of cardiorespiratory fitness, but the accuracy with which ht(2)/Z can predict VO(2max) has not previously been examined in overweight adolescents. The impedance index was used as a predictor of VO(2max) in 87 overweight girls and 47 overweight boys ages 12 to 17 with mean BMI of 38.6 + or - 7.3 and 42.5 + or - 8.2 in girls and boys respectively. The Bland Altman procedure assessed agreement between predicted and actual VO(2max). Predicted VO(2max) was significantly correlated with measured VO(2max) (r(2)=0.48, P<0.0001). Using the Bland Altman procedure, there was significant magnitude bias (r(2)=0.10; P<0.002). The limits of agreement for predicted relative to actual VO(2max) were -589 to 574 mL O(2)/min. The impedance index was highly correlated with VO(2max) in overweight adolescents. However, using BIA data to predict maximal oxygen uptake over-predicted VO(2max) at low levels of oxygen consumption and under-predicted VO(2max) at high levels of oxygen consumption. This magnitude bias, along with the large limits of agreement of BIA-derived predicted VO(2max), limit its usefulness in the clinical setting for overweight adolescents.
Dixon, Curt B; Deitrick, Ronald W; Pierce, Joseph R; Cutrufello, Paul T; Drapeau, Linda L
2005-02-01
The purpose of this study was to compare percent body fat (%BF) estimated by air displacement plethysmography (ADP) and leg-to-leg bioelectrical impedance analysis (LBIA) with hydrostatic weighing (HW) in a group (n = 25) of NCAA Division III collegiate wrestlers. Body composition was assessed during the preseason wrestling weight certification program (WCP) using the NCAA approved methods (HW, 3-site skinfold [SF], and ADP) and LBIA, which is currently an unaccepted method of assessment. A urine specific gravity less than 1.020, measured by refractometry, was required before all testing. Each subject had all of the assessments performed on the same day. LBIA measurements (Athletic mode) were determined using a Tanita body fat analyzer (model TBF-300A). Hydrostatic weighing, corrected for residual lung volume, was used as the criterion measurement. The %BF data (mean +/- SD) were LBIA (12.3 +/- 4.6), ADP (13.8 +/- 6.3), SF (14.2 +/- 5.3), and HW (14.5 +/- 6.0). %BF estimated by LBIA was significantly (p < 0.01) smaller than HW and SF. There were no significant differences in body density or %BF estimated by ADP, SF, and HW. All methods showed significant correlations (r = 0.80-0.96; p < 0.01) with HW. The standard errors of estimate (SEE) for %BF were 1.68, 1.87, and 3.60%; pure errors (PE) were 1.88, 1.94, and 4.16% (ADP, SF, and LBIA, respectively). Bland-Atman plots for %BF demonstrated no systematic bias for ADP, SF, and LBIA when compared with HW. These preliminary findings support the use of ADP and SF for estimating %BF during the NCAA WCP in Division III wrestlers. LBIA, which consistently underestimated %BF, is not supported by these data as a valid assessment method for this athletic group.
Wu, Y T; Nielsen, D H; Cassady, S L; Cook, J S; Janz, K F; Hansen, J R
1993-05-01
The reliability and validity of measurements obtained with two bioelectrical impedance analyzers (BIAs), an RJL Systems model BIA-103 and a Berkeley Medical Research BMR-2000, were investigated using the manufacturers' prediction equations for the assessment of fat-free mass (FFM) (in kilograms) in children and adolescents. Forty-seven healthy children and adolescents (23 male, 24 female), ranging in age from 8 to 20 years (mean = 12.1, SD = 2.3), participated. In the context of a repeated-measures design, the data were analyzed according to gender and maturation (Tanner staging). Hydrostatic weighing (HYDRO) and Lohman's Siri age-adjusted body density prediction equation served as the criteria for validating the BIA-obtained measurements. High intraclass correlation coefficients (ICC > or = .987) demonstrated good test-retest (between-week) measurement reliability for HYDRO and both BIA methods. Between-method (HYDRO versus BIA) correlation coefficients were high for both boys and girls (r > or = .97). The standard errors of estimate (SEEs) for FFM were slightly larger for boys than for girls and were consistently smaller for the RJL system than for the BMR system (RJL SEE = 1.8 kg for boys, 1.3 kg for girls; BMR SEE = 2.4 kg for boys, 1.9 kg for girls). The coefficients of determination were high for both BIA methods (r2 > or = .929). Total prediction errors (TEs) for FFM showed similar between-method trends (RJL TE = 2.1 kg for boys, 1.5 kg for girls; BMR TE = 4.4 kg for boys, 1.9 kg for girls). This study demonstrated that the RJL BIA with the manufacturer's prediction equations can be used to reliably and accurately assess FFM in 8- to 20-year-old children and adolescents. The prediction of FFM by the BMR system was acceptable for girls, but significant overprediction of FFM for boys was noted.
USDA-ARS?s Scientific Manuscript database
To evaluate the percentage of body fat (%BF)-BMI relationship, identify %BF levels corresponding to adult BMI cut points, and examine %BF-BMI agreement in a diverse Hispanic/Latino population. %BF by bioelectrical impedance analysis was corrected against %BF by 18O dilution in 434 participants of th...
USDA-ARS?s Scientific Manuscript database
The validity of bioelectrical impedance analysis (BIA) for body composition analysis is limited by assumptions relating to body shape. Improvement in BIA technology could overcome these limitations and reduce the population specificity of the BIA algorithm. BIA equations for the prediction of fat ...
Nightingale, Claire M.; Rudnicka, Alicja R.; Owen, Christopher G.; Donin, Angela S.; Newton, Sian L.; Furness, Cheryl A.; Howard, Emma L.; Gillings, Rachel D.; Wells, Jonathan C. K.; Cook, Derek G.; Whincup, Peter H.
2013-01-01
Background Bioelectrical impedance analysis (BIA) is a potentially valuable method for assessing lean mass and body fat levels in children from different ethnic groups. We examined the need for ethnic- and gender-specific equations for estimating fat free mass (FFM) from BIA in children from different ethnic groups and examined their effects on the assessment of ethnic differences in body fat. Methods Cross-sectional study of children aged 8–10 years in London Primary schools including 325 South Asians, 250 black African-Caribbeans and 289 white Europeans with measurements of height, weight and arm-leg impedance (Z; Bodystat 1500). Total body water was estimated from deuterium dilution and converted to FFM. Multilevel models were used to derive three types of equation {A: FFM = linear combination(height+weight+Z); B: FFM = linear combination(height2/Z); C: FFM = linear combination(height2/Z+weight)}. Results Ethnicity and gender were important predictors of FFM and improved model fit in all equations. The models of best fit were ethnicity and gender specific versions of equation A, followed by equation C; these provided accurate assessments of ethnic differences in FFM and FM. In contrast, the use of generic equations led to underestimation of both the negative South Asian-white European FFM difference and the positive black African-Caribbean-white European FFM difference (by 0.53 kg and by 0.73 kg respectively for equation A). The use of generic equations underestimated the positive South Asian-white European difference in fat mass (FM) and overestimated the positive black African-Caribbean-white European difference in FM (by 4.7% and 10.1% respectively for equation A). Consistent results were observed when the equations were applied to a large external data set. Conclusions Ethnic- and gender-specific equations for predicting FFM from BIA provide better estimates of ethnic differences in FFM and FM in children, while generic equations can misrepresent these ethnic differences. PMID:24204625
Hise, Ana Cláudia da Rosa; Gonzalez, Maria Cristina
2018-04-01
The state of hyperhydration in critically ill patients with acute kidney injury (AKI) is associated with increased mortality. Bioelectrical impedance vector analysis (BIVA) appears to be a viable method to access the fluid status of critical patients but has never been evaluated in critical patients with AKI. The objective of this study is to evaluate the hydration status measured using BIVA in critical patients under intensive care at the time of AKI diagnosis and to correlate this measurement with mortality. We assessed the fluid status measured using BIVA in 224 critical patients at the time of AKI diagnosis and correlated it with mortality. To interpret the results, BIVA Software 2002 was used to plot the data from the patients studied on the 95% confidence ellipses of the RX c plane for comparisons between groups (non-survivors, survivors). Variables such as mechanical ventilation, vasoactive drug, and sepsis, among others, were collected. The impedance vector analysis conducted using BIVA Software 2002 indicated changes in the body compositions of patients according to the 95% confidence ellipse between the vectors R/H and X c /H of the group of survivors and the group of deceased patients. Hotelling's test (T 2 = 21.2) and the F test (F = 10.6) revealed significant differences (p < 0.001) between the two groups. These results demonstrate that patients who died presented with a greater hydration volume at the time of AKI diagnosis compared with those who survived. In addition to the hydration status measured using BIVA, the following were also correlated with death: diagnosis at hospitalization, APACHE II score, length of hospital stay, RIFLE score, maximum organ failure, sepsis type, hemoglobin, and AF. The fluid status assessment measured using BIVA significantly demonstrated the difference in hydration between survivors and non-survivors among critically ill patients with AKI. Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Deurenberg, P; Andreoli, A; de Lorenzo, A
1996-01-01
Total body water and extracellular water were measured by deuterium oxide and bromide dilution respectively in 23 healthy males and 25 healthy females. In addition, total body impedance was measured at 17 frequencies, ranging from 1 kHz to 1350 kHz. Modelling programs were used to extrapolate impedance values to frequency zero (extracellular resistance) and frequency infinity (total body water resistance). Impedance indexes (height2/Zf) were computed at all 17 frequencies. The estimation errors of extracellular resistance and total body water resistance were 1% and 3%, respectively. Impedance and impedance index at low frequency were correlated with extracellular water, independent of the amount of total body water. Total body water showed the greatest correlation with impedance and impedance index at high frequencies. Extrapolated impedance values did not show a higher correlation compared to measured values. Prediction formulas from the literature applied to fixed frequencies showed the best mean and individual predictions for both extracellular water and total body water. It is concluded that, at least in healthy individuals with normal body water distribution, modelling impedance data has no advantage over impedance values measured at fixed frequencies, probably due to estimation errors in the modelled data.
Yu, Solomon C. Y.; Powell, Alice; Khow, Kareeann S. F.; Visvanathan, Renuka
2016-01-01
Appendicular skeletal muscle mass (ASM) is a diagnostic criterion for sarcopenia. Bioelectrical impedance analysis (BIA) offers a bedside approach to measure ASM but the performance of BIA prediction equations (PE) varies with ethnicities and body composition. We aim to validate the performance of five PEs in estimating ASM against estimation by dual-energy X-ray absorptiometry (DXA). We recruited 195 healthy adult Australians and ASM was measured using single-frequency BIA. Bland-Altman analysis was used to assess the predictive accuracy of ASM as determined by BIA against DXA. Precision (root mean square error (RMSE)) and bias (mean error (ME)) were calculated according to the method of Sheiner and Beal. Four PEs (except that by Kim) showed ASM values that correlated strongly with ASMDXA (r ranging from 0.96 to 0.97, p < 0.001). The Sergi equation performed the best with the lowest ME of −1.09 kg (CI: −0.84–−1.34, p < 0.001) and the RMSE was 2.09 kg (CI: 1.72–2.47). In men, the Kyle equation performed better with the lowest ME (−0.32 kg (CI: −0.66–0.02) and RMSE (1.54 kg (CI: 1.14–1.93)). The Sergi equation is applicable in adult Australians (Caucasian) whereas the Kyle equation can be considered in males. The need remains to validate PEs in other ethnicities and to develop equations suitable for multi-frequency BIA. PMID:27043617
Santillán-Díaz, Cira; Ramírez-Sánchez, Noemi; Espinosa-Morales, Rolando; Orea-Tejeda, Arturo; Llorente, Luis; Rodríguez-Guevara, Gerardo; Castillo-Martínez, Lilia
2018-03-01
Rheumatoid arthritis (RA) patients frequently have changes in their body composition, with a decrease in muscle mass and an increase in fat mass, a syndrome that is termed rheumatoid cachexia (RC). The prevalence of this nutritional alteration is not well known; there is as yet no consensus, seeing as it depends on the methods, techniques, and cutoff points that are used for its diagnosis. The main aim of this study was to identify RC through assessment by bioelectrical impedance vector analysis (BIVA) and its association with metabolic causes, physical function, and the main disease status, among others. The prevalence of RC was identified in those subjects who fell outside the right lower quadrant of the reference curve of RXc graph of BIVA. Clinical, anthropometric, biochemical and physical activity, emotional status, and diet markers were also evaluated. Ninety-four patients were included (92.55% women). The prevalence of RC assessed by BIVA was 21.28%. BIVA-cachexia patients had a lesser value of handgrip strength vs. patients without BIVA-cachexia 10.2 kg (7.2-13.4) vs. 14.7 kg (9.6-19), p = 0.0062. Disability and folic acid with methotrexate consumption are related to BIVA-cachexia ((OR 4.69, 95% CI 1.33, 16.54, p = 0.016) and (OR 0.19, 95%CI 0.058, 0.651, p = 0.008), respectively). BIVA could represent a valuable tool to assess presence of RC. It is important that RA patients have physical therapy to improve their nutritional status.
Widen, Elizabeth M.; Strain, Gladys; King, Wendy C.; Yu, Wenwen; Lin, Susan; Goodpaster, Bret; Thornton, John; Courcoulas, Anita; Pomp, Alfons
2014-01-01
Background Few studies have validated bioelectrical impedance analysis (BIA) following bariatric surgery. Methods We examined agreement of BIA (Tanita 310) measures of total body water (TBW) and percent body fat (%fat) before (T0) and 12 months (T12) after bariatric surgery, and change between T0 and T12 with reference measures: deuterium oxide dilution for TBW and three-compartment model (3C) for %fat in a subset of participants (n=50) of the Longitudinal Assessment of Bariatric Surgery-2. Results T0 to T12 median (IQR) change in deuterium TBW and 3C %fat was −6.4 L (6.4 L) and −14.8 % (13.4 %), respectively. There were no statistically significant differences between deuterium and BIA determined TBW [median (IQR) difference: T0 −0.1 L (7.1 L), p=0.75; T12 0.2 L (5.7 L), p=0.35; Δ 0.35 L(6.3 L), p=1.0]. Compared with 3C, BIA underestimated %fat at T0 and T12 [T0 −3.3 (5.6), p<0.001; T12 −1.7 (5.2), p=0.04] but not change [0.7 (8.2), p=0.38]. Except for %fat change, Bland-Altman plots indicated no proportional bias. However, 95 % limits of agreement were wide (TBW 15–22 L, %fat 19–20 %). Conclusions BIA may be appropriate for evaluating group level response among severely obese adults. However, clinically meaningful differences in the accuracy of BIA between individuals exist. PMID:24464517
Heath, E M; Adams, T D; Daines, M M; Hunt, S C
1998-08-01
To compare hydrostatic weighing with and without head submersion and bioelectric impedance analysis (BIA) for measurement of body composition of persons who are morbidly obese. Body composition was determined using 3 methods: hydrostatic weighing with and without head submersion and BIA. Residual volume for the hydrostatic weighing calculation was determined by body plethysmography. Subjects were 16 morbidly obese men (142.5 kg mean body weight) and 30 morbidly obese women (125.9 kg mean body weight) living in the Salt Lake County, Utah, area. Morbid obesity was defined as 40 kg or more over ideal weight. One-way, repeated-measures analysis of variance was followed by Scheffé post hoc tests; body-fat measurement method served as the repeated variable and percentage of body fat as the dependent variable. Men and women were analyzed separately. In addition, degree of agreement between the 3 methods of determining body composition was determined. A regression equation was used to calculate body density for hydrostatic weighing without head submersion. Two new BIA regression equations were developed from the data of the 16 men and 30 women. Values for percentage body fat from hydrostatic weighing with and without head submersion (41.8% vs 41.7%, respectively) were the same for men but differed for women (52.2% vs 49.4%, respectively, P < .0001). Values for body fat percentage measured by BIA were significantly lower for men (36.1%) and women (43.1%) (for both, P < .0001) compared with values from hydrostatic weighing methods. BIA underpredicted percentage body fat by a mean of 5.7% in men and 9.1% in women compared with the traditional hydrostatic weighing method. BIA tended to underpredict the measurement of percentage body fat in male and female subjects who were morbidly obese. Hydrostatic weighing without head submersion provides an accurate, acceptable, and convenient alternative method for body composition assessment of the morbidly obese population in comparison with the traditional hydrostatic weighing method. In population screening or other settings where underwater weighing is impractical, population-specific BIA regression equations should be used because general BIA equations lead to consistent underprediction of percentage body fat compared with hydrostatic weighing.
ASSESSMENT OF BODY FAT IN OBESE PATIENTS PREOPERATIVELY FOR BARIATRIC SURGERY.
Fernandez, Mônica; Toimil, Rosana Farah; Rasslan, Zied; Ilias, Elias Jirjoss; Gradinar, Ana Lúcia Torloni; Malheiros, Carlos Alberto
The study of body composition in patient candidates for bariatric surgery is directly related to the increase and distribution of body fat in the development of cardiovascular disease. To correlate anthropometric indicators and bioelectrical impedance in the assessment of body fat in female candidates for bariatric surgery. Cross-sectional, observational study of 88 women. The weight, height, body mass index and waist circumference data were evaluated in the anthropometric analysis. The body fat was determinate by bioelectrical impedance conducted according to the manufacturer´s recommended technique with a specific severe obesity formula. The patients were divided into two subgroups according to the average waist circumference and body mass index for better analysis of the results. The group had a mean age of 39.7 years (±7.2), average weight of 125.6 kg (±16.2), mean body mass index of 48.7 kg/m2 (±6.4) and the mean waist circumference 137.6 cm (±12.4). Negative and significant relationship between BMI values waist circumference and resistance obtained by bioelectrical impedance were found. By analyzing the two groups the mean BMI and waist circumference, a significant relationship was observed, ie, the higher the degree of obesity less resistance was obtained by bioelectrical impedance. The higher is the obesity the lower is value found for resistance. The increase of anthropometric indicators (BMI and waist circumference) determined reduction in resistance and reactance obtained by bioelectrical impedance analysis in obese women candidates to bariatric surgery. O estudo da composição corporal em pacientes candidatas à cirurgia bariátrica tem relação direta com o aumento e distribuição da gordura corporal e no desenvolvimento de doenças cardiovasculares. Estudar a correlação entre indicadores antropométricos e da bioimpedância elétrica na avaliação da gordura corporal em mulheres candidatas à cirurgia bariátrica. Estudo transversal, observacional com 88 pacientes. Na análise antropométrica foram avaliados os dados de peso, altura, IMC e circunferência da cintura. Para bioimpedância elétrica utilizou-se a técnica recomendada pelo fabricante do aparelho e fórmula específica para obeso grave na determinação da gordura corporal. Para melhor análise dos resultados as pacientes foram divididas em dois subgrupos de acordo com a média de circunferência da cintura e IMC. O grupo apresentou média de idade 39,7 anos (±7,2), média de peso 125,6 kg (±16,2), média de IMC 48,7 kg/m2 (±6,4) e média de circunferência da cintura 137,6 cm (±12,4). Foram encontradas relações negativas e significativas entre os valores de IMC, circunferência da cintura e a resistência obtida através da bioimpedância elétrica. Ao analisar os dois subgrupos de valores médios de IMC e circunferência da cintura, observou-se relação significativa, ou seja, quanto maior o grau de obesidade menor é a resistência obtida através da bioimpedância elétrica. O aumento dos indicadores antropométricos (IMC e circunferência da cintura) determinaram redução nas variáveis resistência e reatância obtidas pela bioimpedância elétrica em mulheres candidatas à cirurgia bariátrica.
Li, Qiang; Li, Xueni; Leng, Yuxin; Zhu, Xi; Yao, Gaiqi
2018-02-01
To assess the nutritional status of severe malnutrition patients with anorexia nervosa by multi-frequency bioelectrical impedance technique, and to provide the basis for nutritional support therapy. A prospective study was conducted. Twenty-six severe malnutrition patients with anorexia nervosa, body mass index (BMI) ≤ 16 kg/m 2 admitted to intensive care unit (ICU) of Peking University Third Hospital and general three ward of Peking University Sixth Hospital from June 1st to September 30th, 2017 were enrolled. The extracellular water (ECW), intracellular water (ICW), ECW/ICW ratio, adipose tissue mass (ATM), lean tissue mass (LTM), total body water/body weight (TBW/WT), ATM/WT, and LTM/WT were measured by multi-frequency bioelectrical impedance meter. Thirty-eighty healthy volunteers with normal nutritional status (23.0 kg/m 2 > BMI > 18.5 kg/m 2 ) matched by gender and height were enrolled as healthy control group. The predictive value of main body composition for nutritional status were analyzed by receiver operating characteristic (ROC) curve. All the patients were female. There was no significant difference in height between two groups, but WT and BMI in the severe malnutrition group were significantly higher than those in the healthy control group [WT (kg): 38.1±4.9 vs. 54.2±3.3, BMI (kg/m 2 ): 13.6±2.5 vs. 21.2±1.1, both P < 0.01]. Compared with the healthy control group, the ECW, ICW, ATM, LTM, ATM/WT and LTM/WT were significantly decreased in the severe malnutrition group [ECW (L): 9.02±0.42 vs. 10.19±0.77, ICW (L): 12.6±0.9 vs.19.1±1.3, ATM (kg): 9.3±1.1 vs. 16.6±1.9, LTM (kg): 16.5±1.5 vs. 26.1±1.7, ATM/WT: 0.26±0.02 vs. 0.30±0.02, LTM/WT: 0.22±0.02 vs. 0.26±0.01, all P < 0.01], the ECW/ICW and TBW/WT were significantly increased in the severe malnutrition group (ECW/ICW: 0.72±0.06 vs. 0.54±0.06, TBW/WT: 0.58±0.02 vs. 0.52±0.02, both P < 0.01). It was shown by ROC curve analysis that the area under ROC curve (AUC) of TBW/WT, ATM/WT, LTM/WT for evaluating severe malnutrition were 0.999, 0.919, 0.954 respectively; when the cut-off of TBW/WT, ATM/WT, LTM/WT were 0.58, 0.28, 0.24 respectively, the sensitivity were 100%, 85%, 80% respectively, and the specificity were 95%, 80%, 91% respectively. Main body composition of severe malnutrition patients with anorexia nervosa changed significantly. Bioelectrical impedance technology can be an effective assessment tool for the nutritional status of such patients.
Quiterio, Ana L; Silva, Analiza M; Minderico, Cláudia S; Carnero, Elvis A; Fields, David A; Sardinha, Luis B
2009-07-01
-Assessing hydration, that is, total body water (TBW) in adolescent athletes should be part of a comprehensive training program. However, there are no specific methods to assess TBW in young athletes. Moreover, the use of traditional techniques developed in healthy youths, based on a 2-compartment model, may yield inaccurate TBW estimates in young athletes. Therefore, the purpose of this study was to assess the accuracy of TBW non-reference field methods with a criterion method (i.e., deuterium dilution) in 118 adolescent athletes. Body volume was assessed by air displacement plethysmography, bone mineral was measured by dual-energy X-ray absorptiometry, and TBW by deuterium dilution. Non-reference TBW methods included 2 bioelectrical impedance analysis techniques (Tanita Body Composition Analyzer, model TBF-310) and bioelectrical impedance spectroscopy (BIS) (model 4000B); the Lohman's hydration constants of fat-free mass (FFM); and 3 derived anthropometric equations developed, respectively, by Kushner et al., Wells et al., and Morgenstern et al. The highest accuracy between TBW estimates and the reference model in both girls and boys was observed using the Lohman's constants (r2= 0.94, SEE = 1.56 kg; r2 = 0.92, SEE = 2.42 kg, respectively; p < 0.001), followed by both foot-to-foot Tanita (r2 = 0.88, SEE = 2.15 kg; r2 = 0.87, SEE = 3.01 kg, respectively; p < 0.001) and BIS (r2 = 0.92, SEE = 1.70 kg; r2 = 0.87, SEE = 3.04 kg, respectively; p < 0.001) with slopes and intercepts not significantly different from the line of identity. The regressions between anthropometric equations and the criterion method deviated from the line of identity (p < 0.05). The practical application of this study is that the specific constants of FFM hydration developed by Lohman seem to accurately estimate TBW in adolescent athletes. Foot-to-foot Tanita and BIS were also found to be valid and non-biased tools for predicting TBW. It would appear that the 3 anthropometric equations used are not appropriate for young athletes.
Wang, Ji-Guang; Zhang, Yi; Chen, Han-E; Li, Yan; Cheng, Xiao-Guang; Xu, Li; Guo, Zhe; Zhao, Xing-Shan; Sato, Tetsuya; Cao, Qi-Yun; Chen, Ke-Min; Li, Biao
2013-01-01
We compared a 4-limb bioelectrical impedance analysis (BIA) system, HBF 359 (Omron), and a 2-limb foot-to-foot device, BC 532 (Tanita), with the standard dual energy X-ray absorptiometry (DXA) and magnetic resonance imaging (MRI) methods for the measurement of body fat percentage (BF), skeletal muscle mass percentage (SMM, or fat-free mass [FFM] for BC 532), and visceral fat level (VF). Body composition was measured in 200 healthy volunteers (100 men and 100 women, mean age 48 years) by HBF 359 and BC 532 and by DXA and MRI. The agreement was assessed by correlation analysis and paired t-test. The correlation coefficients between BIA and DXA or MRI ranged from 0.71 to 0.89 for BF, SMM, and VF by HBF 359 and from 0.77 to 0.90 for BF, FFM, and VF by BC 532 in all subjects and in men and women separately (p < 0.001 for all). Compared with DXA, HBF 359 significantly (p < 0.001) underestimated BF by -5.8% in men and -9.6% in women. Compared with MRI, the corresponding underestimatons (negative) or overestimations (positive) by HBF 359 in men and women were, respectively, +1.9% (p = 0.02) and +1.7% (p = 0.10) for SMM, and +13.3% (p < 0.001) and -8.5% (p = 0.006), for VF. The corresponding values by BC 532 in men and women were -10.7 and -6.2% for BF, -1.4 and -2.5% for FFM, and +20.4 and -18.0% for VF. The BIA devices are accurate in the estimation of body composition, especially skeletal muscle mass or FFM.
Liu, A; Byrne, N M; Ma, G; Nasreddine, L; Trinidad, T P; Kijboonchoo, K; Ismail, M N; Kagawa, M; Poh, B K; Hills, A P
2011-12-01
To develop and cross-validate bioelectrical impedance analysis (BIA) prediction equations of total body water (TBW) and fat-free mass (FFM) for Asian pre-pubertal children from China, Lebanon, Malaysia, Philippines and Thailand. Height, weight, age, gender, resistance and reactance measured by BIA were collected from 948 Asian children (492 boys and 456 girls) aged 8-10 years from the five countries. The deuterium dilution technique was used as the criterion method for the estimation of TBW and FFM. The BIA equations were developed using stepwise multiple regression analysis and cross-validated using the Bland-Altman approach. The BIA prediction equation for the estimation of TBW was as follows: TBW=0.231 × height(2)/resistance+0.066 × height+0.188 × weight+0.128 × age+0.500 × sex-0.316 × Thais-4.574 (R (2)=88.0%, root mean square error (RMSE)=1.3 kg), and for the estimation of FFM was as follows: FFM=0.299 × height(2)/resistance+0.086 × height+0.245 × weight+0.260 × age+0.901 × sex-0.415 × ethnicity (Thai ethnicity =1, others = 0)-6.952 (R (2)=88.3%, RMSE=1.7 kg). No significant difference between measured and predicted values for the whole cross-validation sample was found. However, the prediction equation for estimation of TBW/FFM tended to overestimate TBW/FFM at lower levels whereas underestimate at higher levels of TBW/FFM. Accuracy of the general equation for TBW and FFM was also valid at each body mass index category. Ethnicity influences the relationship between BIA and body composition in Asian pre-pubertal children. The newly developed BIA prediction equations are valid for use in Asian pre-pubertal children.
Miyake, Makito; Owari, Takuya; Iwamoto, Takashi; Morizawa, Yosuke; Hori, Shunta; Marugami, Nagaaki; Shimada, Keiji; Iida, Kota; Ohnishi, Kenta; Gotoh, Daisuke; Tatsumi, Yoshihiro; Nakai, Yasushi; Inoue, Takeshi; Anai, Satoshi; Torimoto, Kazumasa; Aoki, Katsuya; Yoneda, Tatsuo; Tanaka, Nobumichi; Fujimoto, Kiyohide
2018-04-01
The aim of this study was to determine the clinical utility of bioelectrical impedance analysis (BIA) in a cohort of patients with advanced urothelial carcinoma (UC). We prospectively evaluated body composition in 35 patients with locoregional muscle invasive (≥ T2 and N0-2M0) or metastatic UC. Body composition was evaluated using multifrequency BIA at baseline (n = 35) and during chemotherapy in patients receiving neoadjuvant chemotherapy (n = 14). The BIA-predicted body composition index was compared with the computed tomography-measured muscle index and the prognostic nutrition index. Changes in body composition during neoadjuvant chemotherapy were recorded and compared with the incidence of hematological adverse events. There was a significant correlation between the BIA-predicted skeletal muscle index and the computed tomography-measured skeletal muscle index (P = 0.004), while there was no significant correlation between the prognostic nutrition index and the BIA-predicted nutrition index. After the completion of 3 cycles of neoadjuvant chemotherapy, the skeletal muscle index showed a significant decrease (P = 0.016), while the total body fat mass (P = 0.025), body fat percentage (P = 0.013), and body mass index (P = 0.004) showed a significant increase (a tendency toward "sarcopenic obesity"). Patients who experienced grade 2-3 anemia during neoadjuvant chemotherapy showed a significantly lower increase in body mass index compared with patients who did not experience high-grade toxicities (P = 0.032). BIA could contribute to other methods of nutrition and muscle assessment for pretreatment risk stratification in patients with UC. Further study of a larger cohort is required to elucidate the clinical impact of changes in body composition during chemotherapy.
Rezende, Fabiane; Rosado, Lina; Franceschinni, Sylvia; Rosado, Gilberto; Ribeiro, Rita; Marins, João Carlos Bouzas
2007-12-01
The corporal composition evaluation is extremely important for the individual and population nutritional state diagnosis and for the establishment of appropriate clinical-nutritional conducts. An excess of body fat is frequently associated with important metabolic alterations and chronic diseases, such as diabetes, hypertension and dyslipidemia The availability of methods to assess body composition is essential to evaluate health status of individuals. There are several methods for the corporal composition analysis, and it is important to know the limitation of each one and his/her validity so that the obtained estimates are reliable and correctly interpreted. The purpose of this study was to revise the applicability of some nutritional state indicators and corporal composition evaluation methods, such as corporal mass index, waist circumference and waist-hip relation, skinfold measurements, bioelectrical impedance analysis and near-infrared interactance.
Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.
Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon
2010-01-01
Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.
Khan, I.; Hawlader, Sophie Mohammad Delwer Hossain; Arifeen, Shams El; Moore, Sophie; Hills, Andrew P.; Wells, Jonathan C.; Persson, Lars-Åke; Kabir, Iqbal
2012-01-01
The aim of this study was to investigate the validity of the Tanita TBF 300A leg-to-leg bioimpedance analyzer for estimating fat-free mass (FFM) in Bangladeshi children aged 4-10 years and to develop novel prediction equations for use in this population, using deuterium dilution as the reference method. Two hundred Bangladeshi children were enrolled. The isotope dilution technique with deuterium oxide was used for estimation of total body water (TBW). FFM estimated by Tanita was compared with results of deuterium oxide dilution technique. Novel prediction equations were created for estimating FFM, using linear regression models, fitting child's height and impedance as predictors. There was a significant difference in FFM and percentage of body fat (BF%) between methods (p<0.01), Tanita underestimating TBW in boys (p=0.001) and underestimating BF% in girls (p<0.001). A basic linear regression model with height and impedance explained 83% of the variance in FFM estimated by deuterium oxide dilution technique. The best-fit equation to predict FFM from linear regression modelling was achieved by adding weight, sex, and age to the basic model, bringing the adjusted R2 to 89% (standard error=0.90, p<0.001). These data suggest Tanita analyzer may be a valid field-assessment technique in Bangladeshi children when using population-specific prediction equations, such as the ones developed here. PMID:23082630
Repletion of Zinc and Iron Deficiencies Improve Cognition of Premenopausal Women
1998-10-01
bioelectrical Impedance, taste acuity and other indices related to Zn status ~d 30 Measure baseline neuropsychological outcomes on day 8-12 of... taste buds. A circular, 5mm in diameter, stainless steel electrode was used. Subject were comfortably sitting and familiar with the difference between...determined by increasing the stimulation current starting from zero. Taste acuity was measured before and after treatment. Taste acuity was also measured
NASA Astrophysics Data System (ADS)
Danilov, A. A.; Kramarenko, V. K.; Nikolaev, D. V.; Rudnev, S. G.; Salamatova, V. Yu; Smirnov, A. V.; Vassilevski, Yu V.
2013-04-01
In this work, an adaptive unstructured tetrahedral mesh generation technology is applied for simulation of segmental bioimpedance measurements using high-resolution whole-body model of the Visible Human Project man. Sensitivity field distributions for a conventional tetrapolar, as well as eight- and ten-electrode measurement configurations are obtained. Based on the ten-electrode configuration, we suggest an algorithm for monitoring changes in the upper lung area.
ERIC Educational Resources Information Center
Hannon, James C.; Ratliffe, Thomas; Williams, Daniel P.
2006-01-01
The body mass index (BMI), or the ratio of weight in kilograms to the square of height in meters, is widely used to determine the presence or absence of overweight and obesity in adults. Although many consider BMI an acceptable clinical surrogate of body fatness, it does not differentiate between fat and fat-free tissues. Thus, children and…
Seo, Minseok; Heo, Jaeyoung; Yoon, Joon; Kim, Se-Young; Kang, Yoon-Mo; Yu, Jihyun; Cho, Seoae; Kim, Heebal
2017-01-01
The aim of this study was to investigate which of the gut microbes respond to probiotic intervention, as well as study whether they are associated with gastrointestinal symptoms in a healthy adult human. For the experimental purpose, twenty-one healthy adults were recruited and received probiotic mixture, which is composed of five Lactobacilli strains and two Bifidobacteria strains, once a day for 60 days. Defecation survey and Bioelectrical Impedance Analysis were conducted pre- and post-administration to measure phenotypic differences. Stool samples of the subjects were collected twice. The statistical analysis was performed for pair designed metagenome data with 11 phenotypic records of the bioelectrical impedance body composition analyzer and 6 responses of the questionnaires about gastrointestinal symptom. Furthemore, correlation-based network analysis was conducted for exploring complex relationships among microbiome communities. The abundances of Citrobacter, Klebsiella, and Methanobrevibacter were significantly reduced, which are strong candidates to be highly affected by the probiotic administration. In addition, interaction effects were observed between flatulence symptom attenuation and decreasing patterns of the Methanobrevibacter abundance. These results reveal that probiotic intervention modulated the composition of gut microbiota and reduced the abundance of potential pathogens (i.e. Citrobacter and Klebsiella). In addition, methanogens (i.e. Methanobrevibacter) associated with the gastrointestinal symptom in an adult human.
Pérez Camargo, Dana A; Allende Pérez, Silvia R; Rivera Franco, Mónica M; Álvarez Licona, Nelson E; Urbalejo Ceniceros, Víctor I; Figueroa Baldenegro, Lilian E
2017-01-01
Patients with advanced cancer often experience symptoms of disease and treatment that contribute to distress such as weight loss, which is present in up to 85% of cancer patients. Palliative care in these patients focuses on care aimed at improving quality of life. Phase angle (PA) is obtained by bioelectric impedance analysis (BIA) and is associated with cellular function. It is considered a reliable marker of malnutrition. A low PA may suggest deterioration of the cell membrane, which in palliative patients may result in a short-term survival. The aim of this study was to associate PA and survival in palliative patients of the National Cancer Institute of Mexico. We included 452 patients (women, 56.4%); the average PA was 4.0°. The most frequent disease was gastric cancer (39.2%). Mean body mass index (BMI) was 22.84. The average survival of patients with PA ≤ 4° was 86 days, while in the group with PA > 4°, it was 163 days (P > 0.0001). PA showed significant positive correlation with survival time and BMI. Our results corroborate the reliability of PA in Mexican population, as an indicator of survival in palliative care patients compared to the reported literature in other countries.
Validation of bioelectrical impedance analysis to hydrostatic weighing in male body builders.
Volpe, Stella Lucia; Melanson, Edward L; Kline, Gregory
2010-03-01
The purpose of this study was to compare bioelectrical impedance analysis (BIA) to hydrostatic weighing (HW) in male weight lifters and body builders. Twenty-two male body builders and weight lifters, 23 +/- 3 years of age (mean +/- SD), were studied to determine the efficacy of BIA to HW in this population. Subjects were measured on two separate occasions, 6 weeks apart, for test-retest reliability purposes. Participants recorded 3-day dietary intakes and average work-out times and regimens between the two testing periods. Subjects were, on average, 75 +/- 8 kg of body weight and 175 +/- 7 cm tall. Validation results were as follows: constant error for HW-BIA = 0.128 +/- 3.7%, r for HW versus BIA = -0.294. Standard error of the estimate for BIA = 2.32% and the total error for BIA = 3.6%. Percent body fat was 7.8 +/- 1% from BIA and 8.5 +/- 2% from HW (P > 0.05). Subjects consumed 3,217 +/- 1,027 kcals; 1,848 +/- 768 kcals from carbohydrates; 604 +/- 300 kcals from protein; and 783 +/- 369 kcals from fat. Although work-outs differed among one another, within subject training did not vary. These results suggest that measurement of percent body fat in male body builders and weight trainers is equally as accurate using BIA or HW.
Wang, Lin; Hui, Stanley Sai-chuen; Wong, Stephen Heung-sang
2014-11-15
The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. A total of 255 healthy Chinese children and adolescents aged 9 to 19 years old (127 males and 128 females) from Tianjin, China, participated in the BIA measurement at 50 kHz between the hand and the foot. The criterion measure of FFM was also employed using dual-energy X-ray absorptiometry (DEXA). FFM estimated from 24 published BIA equations was cross-validated against the criterion measure from DEXA. Multiple linear regression was conducted to examine alternative BIA equation for the studied population. FFM estimated from the 24 published BIA equations yielded high correlations with the directly measured FFM from DEXA. However, none of the 24 equations was statistically equivalent with the DEXA-measured FFM. Using multiple linear regression and cross-validation against DEXA measurement, an alternative prediction equation was determined as follows: FFM (kg)=1.613+0.742×height (cm)2/impedance (Ω)+0.151×body weight (kg); R2=0.95; SEE=2.45 kg; CV=6.5, 93.7% of the residuals of all the participants fell within the 95% limits of agreement. BIA was highly correlated with FFM in Chinese children and adolescents. When the new developed BIA equations are applied, BIA can provide a practical and valid measurement of body composition in Chinese children and adolescents.
Wu, Chun-Shien; Chen, Yu-Yawn; Chuang, Chih-Lin; Chiang, Li-Ming; Dwyer, Gregory B; Hsu, Ying-Lin; Huang, Ai-Chun; Lai, Chung-Liang; Hsieh, Kuen-Chang
2015-05-19
The objectives of this study were to develop a regression model for predicting fat-free mass (FFM) in a population of healthy Taiwanese individuals using standing foot-to-foot bioelectrical impedance analysis (BIA) and to test the model's performance in predicting FFM with different body fat percentages (BF%). We used dual-energy X-ray absorptiometry (DXA) to measure the FFM of 554 healthy Asian subjects (age, 16-75 y; body mass index, 15.8-43.1 kg/m(2)). We also evaluated the validity of the developed multivariate model using a double cross-validation technique and assessed the accuracy of the model in an all-subjects sample and subgroup samples with different body fat levels. Predictors in the all-subjects multivariate model included height(2)/impedance, weight, year, and sex (FFM = 13.055 + 0.204 weight + 0.394 height(2)/Impedance - 0.136 age + 8.125 sex (sex: Female = 0, Male = 1), r(2) = 0.92, standard error of the estimate = 3.17 kg). The correlation coefficients between predictive FFM by BIA (FFMBIA) and DXA-measured FFM (FFMDXA) in female subjects with a total-subjects BF%DXA of <20 %, 20 %-30 %, 30 %-40 % and >40 % were r = 0.87, 0.90, 0.91, 0.89, and 0.94, respectively, with bias ± 2SD of 0.0 ± 3.0 kg, -2.6 ± 1.7 kg, -1.5 ± 2.8 kg, 0.5 ± 2.7 kg, and 2.0 ± 2.9 kg, respectively. The correlation coefficients between FFMBIA and FFMDXA in male subjects with a total-subjects BF%DXA of <10 %, 10 %-20 %, 20 %-30 %, and >30 % were r = 0.89, 0.89, 0.90, 0.93, and 0.91, respectively, with bias ± 2SD of 0.0 ± 3.2 kg, -2.3 ± 2.5 kg, -0.5 ± 3.2 kg, 0.4 ± 3.1 kg, and 2.1 ± 3.2 kg, respectively. The standing foot-to-foot BIA method developed in this study can accurately predict FFM in healthy Asian individuals with different levels of body fat.
Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N
2018-03-01
DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p < 0.0001) from one another with DXA total body less head being highest at 37.8 (7.3) kg, D3-C muscle mass at 21.1 (4.6) kg, and BIS total body intracellular water at 17.4 (3.5) kg. All mass assessment methods correlated with grip strength and jump power (R = 0.35-0.63, p < 0.0002), but not with gait speed or repeat chair rise. Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with all mass measures whereas gait speed was not. None of the selected serum measures correlated with mass. Efforts to optimize muscle mass assessment and identify their relationships with health outcomes are needed.
Bioelectrical impedance analysis of bovine milk fat
NASA Astrophysics Data System (ADS)
Veiga, E. A.; Bertemes-Filho, P.
2012-12-01
Three samples of 250ml at home temperature of 20°C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.
Hofsteenge, Geesje H; Chinapaw, Mai J M; Weijs, Peter J M
2015-10-15
In clinical practice, patient friendly methods to assess body composition in obese adolescents are needed. Therefore, the bioelectrical impedance analysis (BIA) related fat-free mass (FFM) prediction equations (FFM-BIA) were evaluated in obese adolescents (age 11-18 years) compared to FFM measured by dual-energy x-ray absorptiometry (FFM-DXA) and a new population specific FFM-BIA equation is developed. After an overnight fast, the subjects attended the outpatient clinic. After measuring height and weight, a full body scan by dual-energy x-ray absorptiometry (DXA) and a BIA measurement was performed. Thirteen predictive FFM-BIA equations based on weight, height, age, resistance, reactance and/or impedance were systematically selected and compared to FFM-DXA. Accuracy of FFM-BIA equations was evaluated by the percentage adolescents predicted within 5% of FFM-DXA measured, the mean percentage difference between predicted and measured values (bias) and the Root Mean Squared prediction Error (RMSE). Multiple linear regression was conducted to develop a new BIA equation. Validation was based on 103 adolescents (60% girls), age 14.5 (sd1.7) years, weight 94.1 (sd15.6) kg and FFM-DXA of 56.1 (sd9.8) kg. The percentage accurate estimations varied between equations from 0 to 68%; bias ranged from -29.3 to +36.3% and RMSE ranged from 2.8 to 12.4 kg. An alternative prediction equation was developed: FFM = 0.527 * H(cm)(2)/Imp + 0.306 * weight - 1.862 (R(2) = 0.92, SEE = 2.85 kg). Percentage accurate prediction was 76%. Compared to DXA, the Gray equation underestimated the FFM with 0.4 kg (55.7 ± 8.3), had an RMSE of 3.2 kg, 63% accurate prediction and the smallest bias of (-0.1%). When split by sex, the Gray equation had the narrowest range in accurate predictions, bias, and RMSE. For the assessment of FFM with BIA, the Gray-FFM equation appears to be the most accurate, but 63% is still not at an acceptable accuracy level for obese adolescents. The new equation appears to be appropriate but await further validation. DXA measurement remains the method of choice for FFM in obese adolescents. Netherlands Trial Register ( ISRCTN27626398).
Nightingale, Claire M; Rudnicka, Alicja R; Owen, Christopher G; Donin, Angela S; Newton, Sian L; Furness, Cheryl A; Howard, Emma L; Gillings, Rachel D; Wells, Jonathan C K; Cook, Derek G; Whincup, Peter H
2013-01-01
Bioelectrical impedance analysis (BIA) is a potentially valuable method for assessing lean mass and body fat levels in children from different ethnic groups. We examined the need for ethnic- and gender-specific equations for estimating fat free mass (FFM) from BIA in children from different ethnic groups and examined their effects on the assessment of ethnic differences in body fat. Cross-sectional study of children aged 8-10 years in London Primary schools including 325 South Asians, 250 black African-Caribbeans and 289 white Europeans with measurements of height, weight and arm-leg impedance (Z; Bodystat 1500). Total body water was estimated from deuterium dilution and converted to FFM. Multilevel models were used to derive three types of equation {A: FFM = linear combination(height+weight+Z); B: FFM = linear combination(height(2)/Z); C: FFM = linear combination(height(2)/Z+weight)}. Ethnicity and gender were important predictors of FFM and improved model fit in all equations. The models of best fit were ethnicity and gender specific versions of equation A, followed by equation C; these provided accurate assessments of ethnic differences in FFM and FM. In contrast, the use of generic equations led to underestimation of both the negative South Asian-white European FFM difference and the positive black African-Caribbean-white European FFM difference (by 0.53 kg and by 0.73 kg respectively for equation A). The use of generic equations underestimated the positive South Asian-white European difference in fat mass (FM) and overestimated the positive black African-Caribbean-white European difference in FM (by 4.7% and 10.1% respectively for equation A). Consistent results were observed when the equations were applied to a large external data set. Ethnic- and gender-specific equations for predicting FFM from BIA provide better estimates of ethnic differences in FFM and FM in children, while generic equations can misrepresent these ethnic differences.
A Parametric Computational Analysis into Galvanic Coupling Intrabody Communication.
Callejon, M Amparo; Del Campo, P; Reina-Tosina, Javier; Roa, Laura M
2017-08-02
Intrabody Communication (IBC) uses the human body tissues as transmission media for electrical signals to interconnect personal health devices in wireless body area networks. The main goal of this work is to conduct a computational analysis covering some bioelectric issues that still have not been fully explained, such as the modeling of the skin-electrode impedance, the differences associated to the use of constant voltage or current excitation modes, or the influence on attenuation of the subject's anthropometrical and bioelectric properties. With this aim, a computational finite element model has been developed, allowing the IBC channel attenuation as well as the electric field and current density through arm tissues to be computed as a function of these parameters. As a conclusion, this parametric analysis has in turn permitted us to disclose some knowledge about the causes and effects of the above-mentioned issues, thus explaining and complementing previous results reported in the literature.
Resistivity and phase in localized BIA
NASA Astrophysics Data System (ADS)
Shiffman, C. A.; Aaron, R.; Amoss, V.; Therrien, J.; Coomler, K.
1999-10-01
We describe a system for highly reproducible non-invasive rf impedance measurements as a function of position along body segments such as the thigh. Results are reported for mainly healthy male and female subjects ranging in age from 19 to 65 and in body-mass index from 15 to 40. A principal conclusion is that the phase of the impedance falls monotonically with increasing distance from the knee, with average values substantially above what is found using standard, whole-body bioelectrical impedance analysis (BIA). To compensate for thigh shape, the data are further analysed using an anatomical model based on reasonable approximations for the distributions of muscle, fat and bone, yielding values of the effective resistivity for current flow parallel to the muscle fibres. The phase and resistivity results are discussed with reference to the whole-body BIA study of maintenance haemodialysis patients by Chertow et al, and in regard to possible physiological correlations observed in this work.
[Bioimpedance vector analysis for body composition in Mexican population].
Espinosa-Cuevas, Maria de los Angeles; Rivas-Rodríguez, Lucía; González-Medina, Enna Cristal; Atilano-Carsi, Ximena; Miranda-Alatriste, Paola; Correa-Rotter, Ricardo
2007-01-01
To construct bivariate tolerance ellipses from impedance values normalized for height, which can be used in Mexican population for the assessment of body composition and compare them with others made in different populations. Body composition was assessed by bioelectrical impedance analysis (BIA) in 439 subjects (204 men and 235 women), 18 to 82 years old, with a BMI between 18-31, using an impedanciometer Quadscan 4000. Resistance, reactance and phase angle were used to calculate bioelectrical impedance vectors and construct bivariate tolerance ellipses. Mean age in men was 47.1 +/- 16 years and 42.4 +/- 13 for women, mean weight (73.4 + 9 vs. 60.1 + 8 kg) and height (1.68 vs. 1.55 m) were significant greater in men than in women (p < 0.002). Women in comparison with men, had greater values of impedance (622.96 +/- 66.16 S2 vs. 523.59 +/- 56.56 D) and resistance (618.96 +/- 66.10 Q 61.97 vs. 521.73 +/- 61.97 2), as well as of resistance and reactance standardized by height (398.24 +/-46.30 S2/m vs. 308.66 +/- 38.44) (44.32 +/- 7.14 i/m vs. 39.75 +/-6.29) respectively, with a significant difference in all of them (p < 0.0001). Similarly, the reactance was greater in females, nevertheless this difference did not reach statistical significance (68.96 +/- 11.17 vs. 67.18 +/- 10.3; p = 0.0861). The phase angle was greater in men than in women, with a statistically significant difference (7.330 +/- 0.88 vs. 6.360 +/- 0.97; p < 0.0001). Bivariate tolerance ellipses (50%, 75% and 95%) derived from Mexican subjects showed a significant upward deviation (p < 0.05) from previously published references from Mexican American and Italian populations. New ellipses of tolerance were therefore constructed for the Mexican population. Bioimpedance vectors in Mexican subjects are significantly different from the existing ones, supporting the need of population specific bivariate tolerance ellipses for the evaluation of body composition.
Langer, Raquel D; Matias, Catarina N; Borges, Juliano H; Cirolini, Vagner X; Páscoa, Mauro A; Guerra-Júnior, Gil; Gonçalves, Ezequiel M
2018-03-26
Bioelectrical impedance analysis (BIA) is a practical and rapid method for making a longitudinal analysis of changes in body composition. However, most BIA validation studies have been performed in a clinical population and only at one moment, or point in time (cross-sectional study). The aim of this study is to investigate the accuracy of predictive equations based on BIA with regard to the changes in fat-free mass (FFM) in Brazilian male army cadets after 7 mo of military training. The values used were determined using dual-energy X-ray absorptiometry (DXA) as a reference method. The study included 310 male Brazilian Army cadets (aged 17-24 yr). FFM was measured using eight general predictive BIA equations, with one equation specifically applied to this population sample, and the values were compared with results obtained using DXA. The student's t-test, adjusted coefficient of determination (R2), standard error of estimation (SEE), Lin's approach, and the Bland-Altman test were used to determine the accuracy of the predictive BIA equations used to estimate FFM in this population and between the two moments (pre- and post-moment). The FFM measured using the nine predictive BIA equations, and determined using DXA at the post-moment, showed a significant increase when compared with the pre-moment (p < 0.05). All nine predictive BIA equations were able to detect FFM changes in the army cadets between the two moments in a very similar way to the reference method (DXA). However, only the one BIA equation specific to this population showed no significant differences in the FFM estimation between DXA at pre- and post-moment of military routine. All predictive BIA equations showed large limits of agreement using the Bland-Altman approach. The eight general predictive BIA equations used in this study were not found to be valid for analyzing the FFM changes in the Brazilian male army cadets, after a period of approximately 7 mo of military training. Although the BIA equation specific to this population is dependent on the amount of FFM, it appears to be a good alternative to DXA for assessing FFM in Brazilian male army cadets.
Raymond, Christiana J; Dengel, Donald R; Bosch, Tyler A
2018-03-01
Raymond, CJ, Dengel, DR, and Bosch, TA. Total and segmental body composition examination in collegiate football players using multifrequency bioelectrical impedance analysis and dual X-ray absorptiometry. J Strength Cond Res 32(3): 772-782, 2018-The current study examined the influence of player position on the agreement between multifrequency bioelectrical impedance analysis (MfBIA) and dual X-ray absorptiometry (DXA) when assessing total and segmental percent body fat (BF%), fat mass (FM), and fat-free mass (FFM) in National Collegiate Athletic Association Division I collegiate football athletes. Forty-four male collegiate athletes (age = 19 ± 1 year; height = 1.9 ± 1.0 m; and body mass = 106.4 ± 18.8 kg) participated. Player positions included: offensive linemen (OL; n = 7), tight ends (TE; n = 4), wide receivers (WR; n = 9), defensive linemen (DL; n = 6), defensive backs (DB; n = 8), linebackers (LB; n = 6), and running backs (RB; n = 4). Total and segmental body composition measured using MfBIA were compared with values obtained using DXA. Compared with DXA, MfBIA underestimated BF% (3.0 ± 3.8%), total FM (2.5 ± 4.3 kg), arm FM (0.4 ± 0.8 kg), arm FFM (1.4 ± 0.9 kg), leg FM (2.8 ± 2.0 kg), and leg FFM (5.4 ± 2.4 kg) (all p < 0.001; arm FM p = 0.002) and overestimated total FFM (-2.4 ± 4.5 kg) (p < 0.001). Limits of agreement (LOAs) were: ±7.39% (BF%), ±8.50 kg (total FM), ±1.50 kg (arm FM), ±1.83 kg (arm FFM), ±3.83 kg (leg FM), ±4.62 kg (leg FFM), and ±8.83 kg (total FFM). No significant differences were observed between devices for trunk FM (-0.3 ± 3.0 kg; p = 0.565) and trunk FFM (0.4 ± 2.4 kg; p = 0.278), with LOAs of ±5.92 and ±4.69 kg, respectively. Player position significantly affected all between-device mean body composition measurement differences (adjusted p ≤ 0.05), with OL demonstrating the greatest effect on each variable. Therefore, MfBIA does not seem accurate in examining between-player body composition in college football players.
Estimation of fat-free mass in Asian neonates using bioelectrical impedance analysis
Tint, Mya-Thway; Ward, Leigh C; Soh, Shu E; Aris, Izzuddin M; Chinnadurai, Amutha; Saw, Seang Mei; Gluckman, Peter D; Godfrey, Keith M; Chong, Yap-Seng; Kramer, Michael S; Yap, Fabian; Lingwood, Barbara; Lee, Yung Seng
2016-01-01
The aims of this study were to develop and validate a prediction equation of fat-free mass (FFM) based on bioelectrical impedance analysis (BIA) and anthropometry using air displacement plethysmography (ADP) as a reference in Asian neonates and to test the applicability of the prediction equations in independent Western cohort. A total of 173 neonates at birth and 140 at week-2 of age were included. Multiple linear regression analysis was performed to develop the prediction equations in a two-third randomly selected subset and validated on the remaining one-third subset at each time point and in an independent Queensland cohort. FFM measured by ADP was the dependent variable and anthropometric measures, sex and impedance quotient (L2/R50) were independent variables in the model. Accuracy of prediction equations were assessed using intra-class correlation and Bland-Altman analyses. L2/R50 was the significant predictor of FFM at week-2 but not at birth. Compared to the model using weight, sex and length, including L2/R50 slightly improved the prediction with a bias of 0.01kg with 2SD limits of agreement (LOA) (0.18, −0.20). Prediction explained 88.9% of variation but not beyond that of anthropometry. Applying these equations to Queensland cohort provided similar performance at the appropriate age. However, when the Queensland equations were applied to our cohort, the bias increased slightly but with similar LOA. BIA appears to have limited use in predicting FFM in the first few weeks of life compared to simple anthropometry in Asian populations. There is a need for population and age appropriate FFM prediction equations. PMID:26856420
Agarwal, Rajiv; Bills, Jennifer E; Light, Robert P
2010-11-01
Although obesity is associated with poor outcomes, among patients with chronic kidney disease (CKD), obesity is related to improved survival. These results may be related to poor diagnostic performance of body mass index (BMI) in assessing body fat content. Accordingly, among 77 patients with CKD and 20 controls, body fat percentage was estimated by air displacement plethysmography (ADP), skinfold thickness, and body impedance analysis. Defined by BMI ≥30 kg/m(2), the prevalence of obesity was 20% in controls and 65% in patients with CKD. Defined by ADP, the prevalence increased to 60% among controls and to 90% among patients with CKD. Although sensitivity and positive predictive value of BMI to diagnose obesity were 100%, specificity was 72%, but the negative predictive value was only 30%. BMI correctly classified adiposity in 75%. Regardless of the presence or absence of CKD, subclinical obesity (defined as BMI <30 kg/m(2) but excess body fat by ADP) was often missed in people with low lean body mass. The adjusted odds ratio for subclinical obesity per 1 kg of reduced lean body mass by ADP was 1.14 (95% CI: 1.06 to 1.23; P<0.001). Skinfold thickness measurements correctly classified 94% of CKD patients, but bioelectrical impedance analyzer-assessed body fat estimation did so in only 65%. Air displacement plethysmography-, skinfold thickness-, and bioelectrical impedance analyzer-assessed body fat all provided reproducible estimates of adiposity. Skinfold thickness measurements may be a better test to classify obesity among those with CKD. Given the low negative predictive value of BMI for obesity, our study may provide an explanation of the "obesity paradox."
Estimation of fat-free mass in Asian neonates using bioelectrical impedance analysis.
Tint, Mya-Thway; Ward, Leigh C; Soh, Shu E; Aris, Izzuddin M; Chinnadurai, Amutha; Saw, Seang Mei; Gluckman, Peter D; Godfrey, Keith M; Chong, Yap-Seng; Kramer, Michael S; Yap, Fabian; Lingwood, Barbara; Lee, Yung Seng
2016-03-28
The aims of this study were to develop and validate a prediction equation of fat-free mass (FFM) based on bioelectrical impedance analysis (BIA) and anthropometry using air-displacement plethysmography (ADP) as a reference in Asian neonates and to test the applicability of the prediction equations in an independent Western cohort. A total of 173 neonates at birth and 140 at two weeks of age were included. Multiple linear regression analysis was performed to develop the prediction equations in a two-third randomly selected subset and validated on the remaining one-third subset at each time point and in an independent Queensland cohort. FFM measured by ADP was the dependent variable, and anthropometric measures, sex and impedance quotient (L2/R50) were independent variables in the model. Accuracy of prediction equations was assessed using intra-class correlation and Bland-Altman analyses. L2/R50 was the significant predictor of FFM at week two but not at birth. Compared with the model using weight, sex and length, including L2/R50 slightly improved the prediction with a bias of 0·01 kg with 2 sd limits of agreement (LOA) (0·18, -0·20). Prediction explained 88·9 % of variation but not beyond that of anthropometry. Applying these equations to the Queensland cohort provided similar performance at the appropriate age. However, when the Queensland equations were applied to our cohort, the bias increased slightly but with similar LOA. BIA appears to have limited use in predicting FFM in the first few weeks of life compared with simple anthropometry in Asian populations. There is a need for population- and age-appropriate FFM prediction equations.
Kuchnia, Adam; Earthman, Carrie; Teigen, Levi; Cole, Abigail; Mourtzakis, Marina; Paris, Michael; Looijaard, Willem; Weijs, Peter; Oudemans-van Straaten, Heleen; Beilman, Gregory; Day, Andrew; Leung, Roger; Compher, Charlene; Dhaliwal, Rupinder; Peterson, Sarah; Roosevelt, Hannah; Heyland, Daren K
2017-09-01
In critically ill patients, muscle loss is associated with adverse outcomes. Raw bioelectrical impedance analysis (BIA) parameters (eg, phase angle [PA] and impedance ratio [IR]) have received attention as potential markers of muscularity, nutrition status, and clinical outcomes. Our objective was to test whether PA and IR could be used to assess low muscularity and predict clinical outcomes. Patients (≥18 years) having an abdominal computed tomography (CT) scan and admitted to intensive care underwent multifrequency BIA within 72 hours of scan. CT scans were landmarked at the third lumbar vertebra and analyzed for skeletal muscle cross-sectional area (CSA). CSA ≤170 cm 2 for males and ≤110 cm 2 for females defined low muscularity. The relationship between PA (and IR) and CT muscle CSA was evaluated using multivariate regression and included adjustments for age, sex, body mass index, Charlson Comorbidity Index, and admission type. PA and IR were also evaluated for predicting discharge status using dual-energy x-ray absorptiometry-derived cut-points for low fat-free mass index. Of 171 potentially eligible patients, 71 had BIA and CT scans within 72 hours. Area under the receiver operating characteristic (c-index) curve to predict CT-defined low muscularity was 0.67 ( P ≤ .05) for both PA and IR. With covariates added to logistic regression models, PA and IR c-indexes were 0.78 and 0.76 ( P < .05), respectively. Low PA and high IR predicted time to live ICU discharge. Our study highlights the potential utility of PA and IR as markers to identify patients with low muscularity who may benefit from early and rigorous intervention.
Reliability and concurrent validity of Futrex and bioelectrical impedance.
Vehrs, P; Morrow, J R; Butte, N
1998-11-01
Thirty Caucasian males (aged 19-32yr) participated in this study designed to investigate the reliability of multiple bioelectrical impedance analysis (BIA) and near-infrared spectroscopy (Futrex, FTX) measurements and the validity of BIA and FTX estimations of hydrostatically (UW) determined percent body fat (%BF). Two BIA and two FTX instruments were used to make 6 measurements each of resistance (R) and optical density (OD) respectively over a 30 min period on two consecutive days. Repeated measures ANOVA indicated that FTX and BIA, using manufacturer's equations, significantly (p<0.01) under predicted UW by 2.4 and 3.8%BF respectively. Standard error of estimate (SEE) and total error (TE) terms provided by regression analysis for FTX (4.6 and 5.31%BF respectively) and BIA (5.65 and 6.95%BF, respectively) were high. Dependent t-tests revealed no significant differences in either FTX or BIA predictions of %BF using two machines. Intraclass reliabilities for BIA and FTX estimates of UW %BF across trials, days, and machines all exceeded 0.97. A significant random error term associated with FTX and a significant subject-by-day interaction associated with BIA was revealed using the generalizability model. Although FTX and BIA estimates of UW %BF were reliable, due to the significant underestimation of UW %BF and high SEE and TE, neither FTX nor BIA were considered valid estimates of hydrostatically determined %BF.
Więch, Paweł; Dąbrowski, Mariusz; Bazaliński, Dariusz; Sałacińska, Izabela; Korczowski, Bartosz; Binkowska-Bury, Monika
2018-04-17
The phase angle (PhA) seems to be a reliable screening tool for the identification of malnutrition risk in hospitalized children with inflammatory bowel disease (IBD). The aim of the present study was to assess the body composition and nutritional status of hospitalized children and adolescents with IBD by using bioelectrical impedance analysis (BIA) with phase angle (PhA) calculation, which has not been evaluated in hospitalized children with IBD yet. A total of 59 children and adolescents aged 4–18 years, with IBD: 34 ulcerative colitis (UC) and 25 Crohn’s disease (CD) were included in the study. The control group consisted of healthy children and adolescents, strictly matched for gender and age in a 1:1 case-control manner. In both groups, BIA was performed and PhA was calculated. IBD patients had significantly lower PhA (UC: 5.34 ± 1.34 vs. 5.96 ± 0.76, p = 0.040; CD: 5.16 ± 1.18 vs. 5.90 ± 0.62, p = 0.009) compared to the control subjects. Significant changes in selected body composition parameters were observed particularly in CD, especially in fat free mass components. Lower phase angle score together with lower body composition parameters and selected nutrition indicators in children and adolescents with IBD demonstrate their worse nutritional and functional status compared to healthy subjects.
Yamada, Yosuke; Buehring, Bjoern; Krueger, Diane; Anderson, Rozalyn M; Schoeller, Dale A; Binkley, Neil
2017-09-01
Skeletal muscle, in addition to being comprised of a heterogeneous muscle fiber population, also includes extracellular components that do not contribute to positive tensional force production. Here we test segmental bioelectrical impedance spectroscopy (S-BIS) to assess muscle intracellular mass and composition. S-BIS can evaluate electrical properties that may be related to muscle force production. Muscle fiber membranes separate the intracellular components from the extracellular environment and consist of lipid bilayers which act as an electrical capacitor. We found that S-BIS measures accounted for ~85% of the age-related decrease in appendicular muscle power compared with only ~49% for dual-energy x-ray absorptiometry (DXA) measures. Indices of extracellular (noncontractile) and cellular (contractile) compartments in skeletal muscle tissues were determined using the Cole-Cole plot from S-BIS measures. Characteristic frequency, membrane capacitance, and phase angle determined by Cole-Cole analysis together presented a S-BIS complex model that explained ~79% of interindividual variance of leg muscle power. This finding underscores the value of S-BIS to measure muscle composition rather than lean mass as measured by DXA and suggests that S-BIS should be highly informative in skeletal muscle physiology. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Measurement of nutritional status in simulated microgravity by bioelectrical impedance spectroscopy
NASA Technical Reports Server (NTRS)
Bartok, Cynthia; Atkinson, Richard L.; Schoeller, Dale A.
2003-01-01
The potential of bioelectrical impedance spectroscopy (BIS) for assessing nutritional status in spaceflight was tested in two head-down-tilt bed-rest studies. BIS-predicted extracellular water (ECW), intracellular water (ICW), and total body water (TBW) measured using knee-elbow electrode placement were compared with deuterium and bromide dilution (DIL) volumes in healthy, 19- to 45-yr-old subjects. BIS was accurate during 44 h of head-down tilt with mean differences (BIS - DIL) of 0-0.1 kg for ECW, 0.3-0.5 for ICW, and 0.4-0.6 kg for TBW (n = 28). At 44 h, BIS followed the within-individual change in body water compartments with a relative prediction error (standard error of the estimate/baseline volume) of 2.0-3.6% of water space. In the second study, BIS did not detect an acute decrease (-1.41 +/- 0.91 kg) in ICW secondary to 48 h of a protein-free, 800 kcal/day diet (n = 18). BIS's insensitivity to ICW losses may be because they were predominantly (65%) localized to the trunk and/or because there was a general failure of BIS to measure ICW independently of ECW and TBW. BIS may have potential for measuring nutritional status during spaceflight, but its limitations in precision and insensitivity to acute ICW changes warrant further validation studies.
Lu, Hsueh-Kuan; Chen, Yu-Yawn; Yeh, Chinagwen; Chuang, Chih-Lin; Chiang, Li-Ming; Lai, Chung-Liang; Casebolt, Kevin M; Huang, Ai-Chun; Lin, Wen-Long; Hsieh, Kuen-Chang
2017-08-22
The aim of this study was to evaluate leg-to-leg bioelectrical impedance analysis (LBIA) using a four-contact electrode system for measuring abdominal visceral fat area (VFA). The present study recruited 381 (240 male and 141 female) Chinese participants to compare VFA measurements estimated by a standing LBIA system (VFALBIA) with computerized tomography (CT) scanned at the L4-L5 vertebrae (VFA CT ). The total mean body mass index (BMI) was 24.7 ± 4.2 kg/m 2 . Correlation analysis, regression analysis, Bland-Altman plot, and paired sample t-tests were used to analyze the accuracy of the VFA LBIA . For the total subjects, the regression line was VFA LBIA = 0.698 VFA CT + 29.521, (correlation coefficient (r) = 0.789, standard estimate of error (SEE) = 24.470 cm 2 , p < 0.001), Lin's correlation coefficient (CCC) was 0.785; and the limit of agreement (LOA; mean difference ±2 standard deviation) ranged from -43.950 to 67.951 cm 2 , LOA% (given as a percentage of mean value measured by the CT) was 48.2%. VFA LBIA and VFA CT showed significant difference (p < 0.001). Collectively, the current study indicates that LBIA has limited potential to accurately estimate visceral fat in a clinical setting.
Silva, S R; Afonso, J; Monteiro, A; Morais, R; Cabo, A; Batista, A C; Guedes, C M; Teixeira, A
2018-06-01
Carcass data were collected from 24 kids (average live weight of 12.5±5.5 kg; range 4.5 to 22.4 kg) of Jarmelista Portuguese native breed, to evaluate bioelectrical impedance analysis (BIA) as a technique for prediction of light kid carcass and muscle chemical composition. Resistance (Rs, Ω) and reactance (Xc, Ω), were measured in the cold carcasses with a single frequency bioelectrical impedance analyzer and, together with impedance (Z, Ω), two electrical volume measurements (VolA and VolB, cm2/Ω), carcass cold weight (CCW), carcass compactness and several carcass linear measurements were fitted as independent variables to predict carcass composition by stepwise regression analysis. The amount of variation explained by VolA and VolB only reached a significant level (P<0.01 and P<0.05, respectively) for muscle weight, moisture, protein and fat-free soft tissue content, even so with low accuracy, with VolA providing the best results (0.326⩽R 2⩽0.366). Quite differently, individual BIA parameters (Rs, Xc and Z) explained a very large amount of variation in dissectible carcass fat weight (0.814⩽R 2⩽0.862; P<0.01). These individual BIA parameters also explained a large amount of variation in subcutaneous and intermuscular fat weights (respectively 0.749⩽R 2⩽0.793 and 0.718⩽R 2⩽0.760; P<0.01), and in muscle chemical fat weight (0.663⩽R 2⩽0.684; P<0.01). Still significant but much lower was the variation in muscle, moisture, protein and fat-free soft tissue weights (0.344⩽R 2⩽0.393; P<0.01) explained by BIA parameters. Still, the best models for estimation of muscle, moisture, protein and fat-free soft tissue weights included Rs in addition to CCW, and accounted for 97.1% to 99.8% (P<0.01) of the variation observed, with CCW by itself accounting for 97.0% to 99.6% (P<0.01) of that variation. Resistance was the only independent variable selected for the best model predicting subcutaneous fat weight. It was also selected for the best models predicting carcass fat weight (combined with carcass length, CL; R 2=0.943; P<0.01) and intermuscular fat weight (combined with CCW; R 2=0.945; P<0.01). The best model predicting muscle chemical fat weight combined CCW and Z, explaining 85.6% (P<0.01) of the variation observed. These results indicate BIA as a useful tool for prediction of light kids' carcass composition.
NASA Astrophysics Data System (ADS)
Caicedo-Eraso, J. C.; González-Correa, C. H.; González-Correa, C. A.
2013-04-01
A previous study showed that reported BIA equations for body composition are not suitable for Colombian population. The purpose of this study was to develop and validate a preliminary BIA equation for body composition assessment in young females from Colombia, using hydrodensitometry as reference method. A sample of 30 young females was evaluated. Inclusion and exclusion criteria were defined to minimize the variability of BIA. Height, weight, BIA, residual lung volume (RV) and underwater weight (UWW) were measured. A preliminary BIA equation was developed (r2 = 0.72, SEE = 2.48 kg) by stepwise multiple regression with fat-free mass (FFM) as dependent variable and weight, height and impedance measurements as independent variables. The quality of regression was evaluated and a cross-validation against 50% of sample confirmed that results obtained with the preliminary BIA equation is interchangeable with results obtained with hydrodensitometry (r2 = 0.84, SEE = 2.62 kg). The preliminary BIA equation can be used for body composition assessment in young females from Colombia until a definitive equation is developed. The next step will be increasing the sample, including a second reference method, as deuterium oxide dilution (D2O), and using multi-frequency BIA (MF-BIA). It would also be desirable to develop equations for males and other ethnic groups in Colombia.
Body fluid volume and nutritional status in hemodialysis: vector bioelectric impedance analysis.
Espinosa Cuevas, M A; Navarrete Rodriguez, G; Villeda Martinez, M E; Atilano Carsi, X; Miranda Alatriste, P; Tostado Gutiérrez, T; Correa-Rotter, R
2010-04-01
Protein-energy malnutrition and hypervolemia are major causes of morbidity and mortality in patients on chronic hemodialysis (CHD). The methods used to evaluate nutritional status and volume status remain controversial. Vector bioelectric impedance analysis (vector- BIA) has recently been developed to assess both nutritional status and tissue hydration. The purpose of the study was to assess the nutritional status and volume status of patients on CHD with conventional nutritional assessment methods and with vector-BIA and then to compare the resulting findings. 76 Mexican patients on CHD were studied. Nutritional status and body composition were assessed with anthropometry, biochemical variables, and the modified Bilbrey nutritional index (mBNI), the results were compared with both conventional BIA and vector-BIA. The BNI was used to determine the number of patients with normal nutritional status (n = 27, 35.5%), and mild (n = 31, 40.8%), moderate (n = 10, 13.2%) and severe malnutrition (n = 8, 10.5%). Patients displayed shorter vectors with smaller phase angles or with an overhydration vectorial pattern before the initiation of their hemodialysis session. There was general improvement to normal hydration status post-dialysis (p < 0.05); however, 28% remained overhydrated as assessed by vector-BIA. The vector-BIA results showed that worse malnutrition status was associated with greater volume overload (p < 0.05). Diabetes mellitus (DM) was associated with shorter vectors with smaller phase angles (a vectorial pattern of overhydration and cachexia) (p < 0.05). Patients with lower serum creatinine presented with shorter vectors and smaller phase angles (vectorial patterns of malnutrition and/or overhydration) (p < 0.05). In women, lower serum albumin (< 3.4 g/dl) correlated with greater overhydration and malnutrition (p < 0.05). In this population, the vector-BIA showed that 28% of the population remained overhydrated after their hemodialysis session. Diabetics and those with moderate or severe malnutrition were more overhydrated, which is a condition that may be associated with increased cardiovascular morbidity. Because nutritional and volume status are important factors associated with morbidity and mortality in CHD patients, we focused on optimizing the use of existing methods. Our studies suggest that vector-BIA offers a comprehensive and reliable reproducible means of assessing both volume and masses at the bedside and can complement the traditional methods.
Application of phase angle for evaluation of the nutrition status of patients with anorexia nervosa.
Małecka-Massalska, Teresa; Popiołek, Joanna; Teter, Mariusz; Homa-Mlak, Iwona; Dec, Mariola; Makarewicz, Agata; Karakuła-Juchnowicz, Hanna
2017-12-30
The evaluation of the nutrition status of patients has been the subject of interest of many scientific disciplines. Any deviation from normal values is a serious clinical problem. There are multiple nutrition status evaluation methods used including diet history, scales and questionnaires, physical examination, anthropometric measurements, biochemical measurements, function tests, as well as bioelectric impedance analysis or adipometry. Phase angle, obtained by means of bioelectric impedance analysis, is another parameter that is being more and more frequently applied in nutrition status monitoring. It is proportional to body cell mass. Its direct correlation with the cellular nutrition status has been documented. High phase angle values signify well-being, while low phase angle values indicate poor condition of cells. The purpose of this paper was to review the current state of knowledge about the application of phase angle in evaluation and monitoring of the nutrition status of patients with anorexia nervosa on the basis of available literature. It was proven that the phase angle values in patients with anorexia nervosa are much lower compared to healthy people. Detailed observations showed phase angle value increase in the course of treatment. The relevance of the commonly used body mass index (BMI) has been questioned due to significant degree of generalization in the nutrition status evaluation. Thus, there is a need for new, objective parameters for nutrition status evaluation, which will assist in the treatment and monitoring of patients in a more meaningful and reliable way. The existing independent studies equivocally confirm the usefulness of phase angle in the evaluation of nutrition status of patients with anorexia nervosa and its broader application in clinical practice is only a matter of time. However, these are merely attempts and they have not yet found wider application in clinical practice in the treatment of anorexia nervosa.
Spanjer, Moon J; Bultink, Irene E M; de van der Schueren, Marian A E; Voskuyl, Alexandre E
2017-06-01
The aims were to assess the prevalence of malnutrition and to validate bioelectrical impedance analysis (BIA) against whole-body DXA for the assessment of body composition in patients with SSc. Malnutrition was defined as BMI <18.5 kg/m 2 or unintentional weight loss >10% in combination with a fat-free mass index (FFMI) <15 kg/m 2 for women or <17 kg/m 2 for men or BMI <20.0 kg/m 2 (age <70 years) or <22 kg/m 2 (age >70 years). Body composition was assessed in 72 patients with whole-body DXA (Hologic, Discovery A) and BIA (Bodystat Quadscan 400). The manufacturer's equation and the Geneva equation were used to estimate FFM and fat mass. The agreement between BIA and whole-body DXA was assessed with Bland-Altman analysis and intraclass correlation coefficient. Malnutrition was found in 8.3% (n = 6) and low FFMI in 20.8% (n = 15) of patients. The mean difference in FFM between BIA and DXA applying the Geneva equation was 0.02 ( s . d . 2.4) kg, intraclass correlation coefficient 0.97 (95% CI: 0.95, 0.98). Limits of agreement were ±4.6 kg. The manufacturer's equation was less adequate to predict FFM. This study shows a relatively low prevalence of malnutrition in comparison with other studies, but a high prevalence of low FFMI, underlining the necessity of measuring body composition in SSc patients with a standardized and validated method. A good validity of BIA in determining FFM was found at a group level, while at an individual level the FFM may vary by 4.6 kg. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; Martínez-Torres, Javier; González-Ruíz, Katherine; González-Jiménez, Emilio; Schmidt-RioValle, Jacqueline; Garcia-Hermoso, Antonio
2016-01-01
This study aimed to determine thresholds for percentage of body fat (BF%) corresponding to the cut-off values for overweight/obesity as recommended by the International Obesity Task Force (IOTF), using two bioelectrical impedance analyzers (BIA), and described the likelihood of increased cardiometabolic risk in our cohort defined by the IOTF and BF% status. Participants included 1165 children and adolescents (54.9% girls) from Bogotá (Colombia). Body mass index (BMI) was calculated from height and weight. BF% of each youth was assessed first using the Tanita BC-418® followed by a Tanita BF-689®. The sensitivity and specificity of both devices and their ability to correctly classify children as overweight/obesity (≥2 standard deviation), as defined by IOTF, was investigated using receiver operating characteristic (ROC) by sex and age groups (9–11, 12–14, and 13–17 years old); Area under curve (AUC) values were also reported. For girls, the optimal BF% threshold for classifying into overweight/obesity was found to be between 25.2 and 28.5 (AUC = 0.91–0.97) and 23.9 to 26.6 (AUC = 0.90–0.99) for Tanita BC-418® and Tanita BF-689®, respectively. For boys, the optimal threshold was between 16.5 and 21.1 (AUC = 0.93–0.96) and 15.8 to 20.6 (AUC = 0.92–0.94) by Tanita BC-418® and Tanita BF-689®, respectively. All AUC values for ROC curves were statistically significant and there were no differences between AUC values measured by both BIA devices. The BF% values associated with the IOTF-recommended BMI cut-off for overweight/obesity may require age- and sex-specific threshold values in Colombian children and adolescents aged 9–17 years and could be used as a surrogate method to identify individuals at risk of excess adiposity. PMID:27782039
Maddocks, Matthew; Kon, Samantha S C; Jones, Sarah E; Canavan, Jane L; Nolan, Claire M; Higginson, Irene J; Gao, Wei; Polkey, Michael I; Man, William D-C
2015-12-01
Bioelectrical impedance analysis (BIA) provides a simple method to assess changes in body composition. Raw BIA variables such as phase angle provide direct information on cellular mass and integrity, without the assumptions inherent in estimating body compartments, e.g. fat-free mass (FFM). Phase angle is a strong functional and prognostic marker in many disease states, but data in COPD are lacking. Our aims were to describe the measurement of phase angle in patients with stable COPD and determine the construct and discriminate validity of phase angle by assessing its relationship with established markers of function, disease severity and prognosis. 502 outpatients with stable COPD were studied. Phase angle and FFM by BIA, quadriceps strength (QMVC), 4-m gait speed (4MGS), 5 sit-to-stand time (5STS), incremental shuttle walk (ISW), and composite prognostic indices (ADO, iBODE) were measured. Patients were stratified into normal and low phase angle and FFM index. Phase angle correlated positively with FFM and functional outcomes (r = 0.35-0.66, p < 0.001) and negatively with prognostic indices (r = -0.35 to -0.48, p < 0.001). In regression models, phase angle was independently associated with ISW, ADO and iBODE whereas FFM was removed. One hundred and seventy patients (33.9% [95% CI, 29.9-38.1]) had a low phase angle. Phenotypic characteristics included lower QMVC, ISW, and 4MGS, higher 5STS, ADO and iBODE scores, and more exacerbations and hospital days in past year. The proportion of patients to have died was significantly higher in patients with low phase angle compared to those with normal phase angle (8.2% versus 3.6%, p = 0.02). Phase angle relates to markers of function, disease severity and prognosis in patients with COPD. As a directly measured variable, phase angle offers more useful information than fat-free mass indices. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Aslam, Muhammad; Eckhauser, Aaron W.; Dorminy, Cindy A.; Dossett, Cynthia M.; Choi, Leena; Buchowski, Maciej S.
2009-01-01
Background/Objectives Monitoring changes in total fat mass and abdominal adiposity are important in understanding the impact of different types of weight loss interventions on health risks. Our objective was to assess the usefulness of anthropometry and bioelectrical impedance analysis (BIA) in predicting fat mass changes during moderate weight loss. Subjects/Methods Fat mass changes were assessed in 34 overweight adults (24 females, 10 males) after a 12-week supervised weight loss induced by caloric restriction (−30% of requirement) using BIA and DXA. Agreement between BIA and DXA measurements were assessed by Bland-Altman plots. Linear regression modeling was used to predict body and truncal fat mass from anthropometric measures. Results Diet intervention resulted in a significant decrease in body weight (− 7.86 ± 2.87 kg), body mass index (BMI − 2.69 ± 0.98 kg/m2), total body fat (− 5.22 ± 2.32 kg), truncal fat (− 2.80 ± 1.94 kg) and waist circumference (− 5.52 ± 3.57 cm). BMI and body weight were highly correlated with body fat (0.83 and 0.92 in females and 0.94 and 0.92 in males respectively) and truncal fat (0.75 and 0.87 in females; 0.90 and 0.84 in males respectively) during weight loss. Waist circumference was more correlated with truncal fat in males than females (0.94 vs. 0.85 in females). Compared to DXA, BIA underestimated total body fat changes in males (− 8.8 kg, p<0.001) and overestimated total body fat changes in females (+ 2.1 kg, p< 0.001). Conclusions Body mass index, body weight, and waist circumference provide simple and more accurate than BIA estimates of relative changes in total and truncal fat during moderate weight loss in adults. PMID:20161645
Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; Martínez-Torres, Javier; González-Ruíz, Katherine; González-Jiménez, Emilio; Schmidt-RioValle, Jacqueline; Garcia-Hermoso, Antonio
2016-10-04
This study aimed to determine thresholds for percentage of body fat (BF%) corresponding to the cut-off values for overweight/obesity as recommended by the International Obesity Task Force (IOTF), using two bioelectrical impedance analyzers (BIA), and described the likelihood of increased cardiometabolic risk in our cohort defined by the IOTF and BF% status. Participants included 1165 children and adolescents (54.9% girls) from Bogotá (Colombia). Body mass index (BMI) was calculated from height and weight. BF% of each youth was assessed first using the Tanita BC-418® followed by a Tanita BF-689®. The sensitivity and specificity of both devices and their ability to correctly classify children as overweight/obesity (≥2 standard deviation), as defined by IOTF, was investigated using receiver operating characteristic (ROC) by sex and age groups (9-11, 12-14, and 13-17 years old); Area under curve (AUC) values were also reported. For girls, the optimal BF% threshold for classifying into overweight/obesity was found to be between 25.2 and 28.5 (AUC = 0.91-0.97) and 23.9 to 26.6 (AUC = 0.90-0.99) for Tanita BC-418® and Tanita BF-689®, respectively. For boys, the optimal threshold was between 16.5 and 21.1 (AUC = 0.93-0.96) and 15.8 to 20.6 (AUC = 0.92-0.94) by Tanita BC-418® and Tanita BF-689®, respectively. All AUC values for ROC curves were statistically significant and there were no differences between AUC values measured by both BIA devices. The BF% values associated with the IOTF-recommended BMI cut-off for overweight/obesity may require age- and sex-specific threshold values in Colombian children and adolescents aged 9-17 years and could be used as a surrogate method to identify individuals at risk of excess adiposity.
Ndagire, Catherine T; Muyonga, John H; Isabirye, Dan; Odur, Benard; Somda, Serge M A; Bukenya, Richard; Andrade, Juan E; Nakimbugwe, Dorothy
2018-06-04
Accurate measurement of body composition in children and adolescents is important as the quantities of fat and fat-free mass have implications for health risk. The objectives of the present study were: to determine the reliability of Fourier Transform Infrared spectroscopy (FTIR) measurements and; compare the Fat Mass (FM), Fat Free Mass (FFM) and body fat percentage (%BF) values determined by bioelectrical impedance analysis (BIA) to those determined by deuterium dilution method (DDM) to identify correlations and agreement between the two methods. A cross-sectional study was conducted among 203 children and adolescents aged 8-19 years attending schools in Kampala city, Uganda. Pearson product-moment correlation at 5% significance level was considered for assessing correlations. Bland Altman analysis was used to examine the agreement between of FTIR measurements and between estimates by DDM and BIA.. Reliability of measurements was determined by Cronbach's alpha. There was good agreement between the in vivo D 2 O saliva enrichment measurements at 3 and 4 h among the studied age groups based on Bland-Altman plots. Cronbach's alpha revealed that measurements of D 2 O saliva enrichment had very good reliability. For children and young adolescents, DDM and BIA gave similar estimates of FFM, FM, and %BF. Among older adolescents, BIA significantly over-estimated FFM and significantly under-estimated FM and %BF compared to estimates by DDM. The correlation between FFM, FM and %BF estimates by DDM and BIA was high and significant among young and older adolescents and for FFM among children. Reliability of the FTIR spectroscopy measurements was very good among the studied population. BIA is suitable for assessing body composition among children (8-9 years) and young adolescents (10-14 years) but not among older adolescents (15-19 years) in Uganda. The body composition measurements of older adolescents determined by DDM can be predicted using those provided by BIA using population-specific regression equations.
Disorders of nutritional status in sepsis – facts and myths
Wachowska, Ewelina; Słotwiński, Robert
2017-01-01
The problem of diagnosing nutritional status disorders in septic patients remains unresolved. This is associated with the necessity of the introduction of newer and newer methods of assessing nutritional status, often requiring precise and expensive equipment as well as employment of professionals in this field in hospital wards, primarily including intensive care units (ICU). Methods that have been applied thus far for assessing nutritional status, also used in severely ill septic patients, have little impact on improving treatment results. This is due to the high dynamics of changes in nutritional status in these patients, healing process variability in individual patients, and the “mismatch” of methods for assessing nutritional status in relation to the patient’s clinical status. The diagnostic value of the traditional methods of assessing nutritional status, i.e. anthropometric analysis and selected laboratory tests, as markers of nutritional status disorders in septic patients, is still debatable. There is still no precise method that could become the “gold standard” allowing for early identification of malnutrition in these group of patients. Phase angle, bioelectrical impedance vector analysis (BIVA), and the “illness marker”, obtained directly from the resistance, reactance, and impedance, can be used as prognostic or nutritional indices in severely ill septic patients, but the intensity of research on this subject needs to be increased. Detailed assessment of nutritional status should include tests of selected inflammation markers (including TLC, HMGB1, IL-6, IL-10, IL-1ra, sTNFRI). PMID:28702094
Disorders of nutritional status in sepsis - facts and myths.
Kosałka, Katarzyna; Wachowska, Ewelina; Słotwiński, Robert
2017-01-01
The problem of diagnosing nutritional status disorders in septic patients remains unresolved. This is associated with the necessity of the introduction of newer and newer methods of assessing nutritional status, often requiring precise and expensive equipment as well as employment of professionals in this field in hospital wards, primarily including intensive care units (ICU). Methods that have been applied thus far for assessing nutritional status, also used in severely ill septic patients, have little impact on improving treatment results. This is due to the high dynamics of changes in nutritional status in these patients, healing process variability in individual patients, and the "mismatch" of methods for assessing nutritional status in relation to the patient's clinical status. The diagnostic value of the traditional methods of assessing nutritional status, i.e. anthropometric analysis and selected laboratory tests, as markers of nutritional status disorders in septic patients, is still debatable. There is still no precise method that could become the "gold standard" allowing for early identification of malnutrition in these group of patients. Phase angle, bioelectrical impedance vector analysis (BIVA), and the "illness marker", obtained directly from the resistance, reactance, and impedance, can be used as prognostic or nutritional indices in severely ill septic patients, but the intensity of research on this subject needs to be increased. Detailed assessment of nutritional status should include tests of selected inflammation markers (including TLC, HMGB1, IL-6, IL-10, IL-1ra, sTNFRI).
Phase angle as bioelectrical marker to identify elderly patients at risk of sarcopenia.
Basile, Claudia; Della-Morte, David; Cacciatore, Francesco; Gargiulo, Gaetano; Galizia, Gianluigi; Roselli, Mario; Curcio, Francesco; Bonaduce, Domenico; Abete, Pasquale
2014-10-01
Several markers have been associated with sarcopenia in the elderly, including bioelectrical indices. Phase angle (PhA) is an impedance parameter and it has been suggested as an indicator of cellular death. Thus, the relationship between PhA and muscle mass and strength was investigated in 207 consecutively elderly participants (mean age 76.2±6.7years) admitted for multidimensional geriatric evaluation. Muscle strength by grip strength using a hand-held dynamometer and muscle mass was measured by bioimpedentiometer. PhA was calculated directly with its arctangent (resistance/reactance×180°/π). Linear relationship among muscular mass and strength and with clinical and biochemical parameters, including PhA at uni- and multivariate analysis were performed. Linear regression analysis demonstrated that lower level of PhA is associated with reduction in grip strength (y=3.16+0.08x; r=0.49; p<0.001), and even more, with muscle mass (y=3.04+0.25x; r=0.60; p<0001). Multivariate analysis confirms these relationships (grip strength β=0.245, p=0.031; muscular mass β=0.623, p<0.01). Thus, PhA is inversely related to muscle mass and strength in elderly subjects and it may be considered a good bioelectrical marker to identify elderly patients at risk of sarcopenia. Copyright © 2014 Elsevier Inc. All rights reserved.
Bioimpedance profiling of the limbs: Update
NASA Astrophysics Data System (ADS)
Ward, L. C.; Essex, T.; Bartlett, M.; Kilbreath, S.; Brookes, D.
2010-04-01
Bioelectrical impedance spectroscopy (BIS) is now commonly used to assess breast cancer-related lymphoedema. Typically, the ratio of impedances of the two arms, determined at zero frequency (Z0), is used as a quantitative index of the presence of excess lymph. Measurement uses skin electrodes spanning the whole limb. However, lymphoedema may be highly localised and may involve changes other than simple fluid accumulation, e.g. increased fat and fibrosis, that also give rise to changes in impedance-related parameters such as capacitance. We have previously reported (13th ICEBI, Graz, 2007) a prototype mobile electrode probe that replaces the distal sense electrode which, when moved proximally along the arm, provides an impedance profile. We report here the further development of this technology to incorporate real-time measurement of impedance integrated with a digital measuring wheel. This allows exact synchronisation of impedance with position on the arm. A commercial BIS instrument (ImpediMed SFB7) was modified to collect impedance (R and Xc) data every msec and the mean impedance computed for each 10-mm slice. The apparent resistivity values for arm tissue were used to calculate slice volumes. These computed volumes were compared to equivalent slice volumes from perometry and DXA. The system is being further validated by correlating slice impedance parameters with lean tissue volume determined by pQCT (StraTec XCT 3000), for multiple positions along the arm. Ultimately, it is hoped that such measurements will not only allow localised tissue volume measurement but will also provide information of tissue composition in conditions such as lymphoedema.
Lewin, Antoine; Pannier, Bruno; Méline, Julie; Karusisi, Noëlla; Thomas, Frédérique; Chaix, Basile
2014-03-01
Studies of associations between geographic environment and obesity have mostly examined body mass index and focused on residential neighborhoods. We investigated associations between residential neighborhoods, geographic work environments, and work economic sectors and the fat mass index (FMI) and percentage of fat mass (%FM). Data on 4331 participants from the French RECORD Study geolocated at their residence and workplace were analyzed. Body composition was assessed by bioelectrical impedance analyzers. Multilevel linear regression was used to investigate the determinants of FMI and %FM. After adjustment, among men, the FMI and %FM increased independently with decreasing density of population and educational level in the residential neighborhood. Among women, the residential educational level was related to the FMI and %FM. Among men, a higher FMI and %FM were observed among participants working in the construction and transportation/communication sectors than in the education sector. For women, the FMI was higher among participants working in the public administration and health/social work sectors than in the transport/communication sector. A long home-work distance was associated with a higher FMI among women. There was evidence that body mass index cannot fully capture work economic sector effects on fat mass. Public health interventions to reduce social/territorial disparities in obesity should also consider the different contexts to which the participants belong, such as residential environments and work economic sectors. Copyright © 2014 Elsevier Inc. All rights reserved.
Alterations in body fluid content can be detected by bioelectrical impedance analysis.
Scheltinga, M R; Jacobs, D O; Kimbrough, T D; Wilmore, D W
1991-05-01
The electrical resistance across the whole body and its segments to the conduction of a weak alternating current was determined in human subjects under three different conditions: (1) during bed rest, (2) during infusion of 1 liter of saline, and (3) during donation of 1 unit of blood. During bed rest, extracellular and total body water were measured by dilution of bromide and heavy water, respectively. Electrical resistance obtained from electrodes placed on proximal portions of extremities ("proximal resistance") accounted for less than 50% of that determined by electrodes positioned on routinely used portions of a hand and foot ("whole body resistance"). Following saline infusion, resistance determined from the whole body and all its segments fell (P less than 0.001); the magnitude of the drop in both proximal and whole body resistance was inversely related to the volume of total body water (TBW) (r = -0.82, P less than 0.002, and r = -0.73, P less than 0.01, respectively). In contrast, blood donation was associated with significantly increased resistance at both measurement sites. TBW predicted from anthropometrics was inversely related to both proximal (r = -0.90, P less than 0.001) and whole body resistance (r = -0.75, P less than 0.001). Bioelectrical impedance analysis is a simple technique which may be useful in monitoring minimal alterations in TBW. Furthermore, altered fluid status may be predicted more accurately by changes in proximal resistance compared to changes in traditionally used whole body resistance.
Wong, William W; Strizich, Garrett; Heo, Moonseong; Heymsfield, Steven B; Himes, John H; Rock, Cheryl L; Gellman, Marc D; Siega-Riz, Anna Maria; Sotres-Alvarez, Daniela; Davis, Sonia M; Arredondo, Elva M; Van Horn, Linda; Wylie-Rosett, Judith; Sanchez-Johnsen, Lisa; Kaplan, Robert C; Mossavar-Rahmani, Yasmin
2016-07-01
To evaluate the percentage of body fat (%BF)-BMI relationship, identify %BF levels corresponding to adult BMI cut points, and examine %BF-BMI agreement in a diverse Hispanic/Latino population. %BF by bioelectrical impedance analysis was corrected against %BF by (18) O dilution in 434 participants of the ancillary Hispanic Community Health Study/Study of Latinos. Corrected %BF was regressed against 1/BMI in the parent study (n = 15,261), fitting models for each age group, by sex, and Hispanic/Latino background; predicted %BF was then computed for each BMI cut point. Bioelectrical impedance analysis underestimated %BF by 8.7 ± 0.3% in women and 4.6 ± 0.3% in men (P < 0.0001). The %BF-BMI relationship was nonlinear and linear for 1/BMI. Sex- and age-specific regression parameters between %BF and 1/BMI were consistent across Hispanic/Latino backgrounds (P > 0.05). The precision of the %BF-1/BMI association weakened with increasing age in men but not women. The proportion of participants classified as nonobese by BMI but as having obesity by %BF was generally higher among women and older adults (16.4% in women vs. 12.0% in men aged 50-74 years). %BF was linearly related to 1/BMI with consistent relationship across Hispanic/Latino backgrounds. BMI cut points consistently underestimated the proportion of Hispanics/Latinos with excess adiposity. © 2016 The Obesity Society.
Bruni, Vincenzina; Dei, Metella; Morelli, Chiara; Schettino, M Teresa; Balzi, Daniela; Nuvolone, Daniela
2011-12-01
The purpose of the study was to identify diagnostic criteria that can distinguish between subjects with functional hypothalamic amenorrhea largely related to minimal energy deficiency and those in whom failure of adaptive response to stress prevails. We studied 59 young women with secondary amenorrhea related to modest eating disorders and 58 who complained of stressful events in their history. We assessed anthropometric measurements, body composition using dual energy X-ray absorptiometry (DEXA) and bioelectrical impedance analysis (BIA), and basal endocrine profile. Subjects with disordered eating had lower body mass index (BMI), fat mass (FM) measured with both techniques, lumbar mineral density and direct and indirect measures of lean mass. Leptin and free tri-iodothyronine(FT(3)) concentrations also proved lower in the group of subjects with eating disorders, although there was no significant difference in cortisol between the two groups. Leptin levels were positively associated not only with fat mass, but also with body cell mass indexed to height and phase angle, parameters studied with BIA as expression of active lean compartment. A multivariate model confirmed the utility of integrating endocrine data with the study of body composition. The use of bioelectrical impedance analysis proved to be, in clinical use, a valid diagnostic alternative to DEXA, especially considering body cell mass and phase angle. Copyright © 2011 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
van Venrooij, Lenny M W; Verberne, Hein J; de Vos, Rien; Borgmeijer-Hoelen, Mieke M M J; van Leeuwen, Paul A M; de Mol, Bas A J M
2010-12-01
To measure undernutrition in terms of fat free mass (FFM), there are several options. The aim of this study was to assess agreement in FFM between the portable, bedside bioelectrical impedance spectrometry (BIS) and relatively expensive, non-portable dual-energy X-ray absorptiometry (DXA) in patients undergoing cardiac surgery. In a prospective study, body composition measurements by BIS and DXA were performed two weeks prior and two months after cardiac surgery. Preoperative and postoperative agreement in FFM between BIS and DXA were analyzed with Bland and Altman plots. Twenty-six patients were analyzed. BIS overestimated preoperative and postoperative FFM by 2 kg compared to DXA (2.3 kg (95%CI: -3.5-8.1 kg) and 2.1 kg (95%CI: -4.5-8.7 kg), respectively). BIS underestimated FFM change by -0.5% (95%CI: -8.4-7.5%). There is a large inter-individual variation between BIS and DXA. This hinders the interchange-ability of BIS and DXA in routine clinical practice and may lead to misclassifications and thereby inappropriate nutritional treatment and possible postoperative complications. To evaluate nutritional therapy in patients undergoing cardiac surgery, we advocate the use of DXA assessed FFM in parallel to BIS assessed extracellular and intracellular water and FFM. Copyright © 2010 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Ranasinghe, Chathuranga; Gamage, Prasanna; Katulanda, Prasad; Andraweera, Nalinda; Thilakarathne, Sithira; Tharanga, Praveen
2013-09-03
Body Mass Index (BMI) is used as a useful population-level measure of overweight and obesity. It is used as the same for both sexes and for all ages of adults. The relationship between BMI and body fat percentage (BF %) has been studied in various ethnic groups to estimate the capacity of BMI to predict adiposity. We aimed to study the BMI-BF% relationship, in a group of South Asian adults who have a different body composition compared to presently studied ethnic groups. We examined the influence of age, gender in this relationship and assessed its' linearity or curvilinearity. A cross sectional study was conducted, where adults of 18-83 years were grouped into young (18-39 years) middle aged (40-59 years) and elderly (>60 years). BF% was estimated from bioelectrical impedance analysis. Pearsons' correlation coefficient(r) was calculated to see the relationship between BMI-BF% in the different age groups. Multiple regression analysis was performed to determine the effect of age and gender in the relationship and polynomial regression was carried out to see its' linearity. The relationships between age-BMI, age-BF % were separately assessed. Out of 1114 participants, 49.1% were males. The study sample represented a wide range of BMI values (14.8-41.1 kg/m2,Mean 23.8 ± 4.2 kg/m2). A significant positive correlation was observed between BMI-BF%, in males (r =0.75, p < 0.01; SEE = 4.17) and in females (r = 0.82, p < 0.01; SEE = 3.54) of all ages. Effect of age and gender in the BMI-BF% relationship was significant (p < 0.001); with more effect from gender. Regression line found to be curvilinear in nature at higher BMI values where females (p < 0.000) having a better fit of the curve compared to males (p < 0.05). In both genders, with increase of age, BMI seemed to increase in curvilinear fashion, whereas BF% increased in a linear fashion. BMI strongly correlate with BF % estimated by bioelectrical impedance, in this sub population of South Asian adults. This relationship was curvilinear in nature and was significantly influenced by age and gender. Our findings support the importance of taking age and gender in to consideration when using BMI to predict body fat percentage/obesity, in a population.
NASA Astrophysics Data System (ADS)
Dumler Md, Francis
2010-04-01
Bioelectrical impedance analysis is an established technique for body composition analysis. The phase angle parameter, an index of body cell mass, tissue hydration, and membrane integrity, makes it suitable for assessing nutritional status and survivability. We evaluated the significance of a low phase angle value on nutritional status and mortality in 285 chronic dialysis patients during a longitudinal prospective observational study. Patients in the lower phase angle tertile had decreased body weight, body mass index, fat free mass, body cell mass, and lower serum albumin concentrations than those in the higher tertile (P<001). In addition, mortality rates were significantly lower (P=0.05) in the highest tertile patients. In conclusion, the phase angle is a useful method for identifying dialysis patients at high risk for malnutrition and increased mortality.
Common relationships among proximate composition components in fishes
Hartman, K.J.; Margraf, F.J.
2008-01-01
Relationships between the various body proximate components and dry matter content were examined for five species of fishes, representing anadromous, marine and freshwater species: chum salmon Oncorhynchus keta, Chinook salmon Oncorhynchus tshawytscha, brook trout Salvelinus fontinalis, bluefish Pomatomus saltatrix and striped bass Morone saxatilis. The dry matter content or per cent dry mass of these fishes can be used to reliably predict the per cent composition of the other components. Therefore, with validation it is possible to estimate fat, protein and ash content of fishes from per cent dry mass information, reducing the need for costly and time-consuming laboratory proximate analysis. This approach coupled with new methods of non-lethal estimation of per cent dry mass, such as from bioelectrical impedance analysis, can provide non-destructive measurements of proximate composition of fishes. ?? 2008 The Authors.
2018-04-26
Acute Undifferentiated Leukemia; Adult Acute Myeloid Leukemia With 11q23 (MLL) Abnormalities; Adult Acute Myeloid Leukemia With Del(5q); Adult Acute Myeloid Leukemia With Inv(16)(p13;q22); Adult Acute Myeloid Leukemia With t(15;17)(q22;q12); Adult Acute Myeloid Leukemia With t(16;16)(p13;q22); Adult Acute Myeloid Leukemia With t(8;21)(q22;q22); Mast Cell Leukemia; Myeloid/NK-cell Acute Leukemia; Untreated Adult Acute Lymphoblastic Leukemia; Untreated Adult Acute Myeloid Leukemia
Bioelectrical impedance among rural Bangladeshi Women during pregnancy and in the postpartum period.
Shaikh, Saijuddin; Schulze, Kerry J; Ali, Hasmot; Labrique, Alain B; Shamim, Abu Ahmed; Rashid, Mahbubur; Mehra, Sucheta; Christian, Parul; West, Keith P
2011-06-01
Properties of bioelectrical impedance analysis (BIA) reflect body-composition and may serve as stand-alone indicators of maternal health. Despite these potential roles, BIA properties during pregnancy and lactation in rural South Asian women have not been described previously, although pregnancy and infant health outcomes are often compromised. This paper reports the BIA properties among a large sample of pregnant and postpartum women of rural Bangladesh, aged 12-46 years, participating in a substudy of a community-based, placebo-controlled trial of vitamin A or beta-carotene supplementation. Anthropometry and single frequency (50 kHz) BIA were assessed in 1,435 women during the first trimester (< or =12 weeks gestation), in 1237 women during the third trimester (32-36 weeks gestation), and in 1,141 women at 12-18 weeks postpartum. Resistance and reactance were recorded, and impedance and phase angle were calculated. Data were examined cross-sectionally to maximize sample-size at each timepoint, and the factors relating to BIA properties were explored. Women were typically young, primiparous and lacking formal education (22.2 +/- 6.3 years old, 42.2% primiparous, and 39.7% unschooled among the first trimester participants). Weight (kg), resistance (omega), and reactance (omega) were 42.1 +/- 5.7, 688 +/- 77, and 73 +/- 12 in the first trimester; 47.7 +/- 5.9, 646 +/- 77, and 64 +/- 12 in the third trimester; and 42.7 +/- 5.6, 699 +/- 79, and 72 +/- 12 postpartum respectively. Resistance declined with age and increased with body mass index. Resistance was higher than that observed in other, non-Asian pregnant populations, likely reflecting considerably smaller body-volume among Bangladeshi women. Resistance and reactance decreased in advanced stage of pregnancy as the rate of gain in weight increased, returning to the first trimester values by the three months postpartum. Normative distributions of BIA properties are presented for rural Bangladeshi women across a reproductive cycle that may be related to pregnancy outcomes and ultimately be used for assessing body-composition in this population.
Body composition changes in pregnancy: measurement, predictors and outcomes
Widen, EM; Gallagher, D
2014-01-01
Prevalence of overweight and obesity has risen in the United States over the past few decades. Concurrent with this rise in obesity has been an increase in pregravid body mass index and gestational weight gain affecting maternal body composition changes in pregnancy. During pregnancy, many of the assumptions inherent in body composition estimation are violated, particularly the hydration of fat-free mass, and available methods are unable to disentangle maternal composition from fetus and supporting tissues; therefore, estimates of maternal body composition during pregnancy are prone to error. Here we review commonly used and available methods for assessing body composition changes in pregnancy, including: (1) anthropometry, (2) total body water, (3) densitometry, (4) imaging, (5) dual-energy X-ray absorptiometry, (6) bioelectrical impedance and (7) ultrasound. Several of these methods can measure regional changes in adipose tissue; however, most of these methods provide only whole-body estimates of fat and fat-free mass. Consideration is given to factors that may influence changes in maternal body composition, as well as long-term maternal and offspring outcomes. Finally, we provide recommendations for future research in this area. PMID:24667754
Macfarlane, Duncan J; Chan, Natalie T-Y; Tse, Michael A; Joe, Glen M
2016-01-01
We aimed to assess the agreement of a commercially available bioelectrical impedance analysis (BIA) device in measuring changes in fat, lean and bone mass over a 10-week lifestyle intervention, with dual energy X-ray absorptiometry (DXA) as reference. A sample of 136 volunteers (18-66 years) underwent a physical activity intervention to enhance lean mass and reduce fat mass. BIA (Tanita BC545) and DXA (Hologic Explorer) measures of whole-body composition were taken at baseline and at the end of the intervention. After an average of 74 ± 18 days intervention, DXA showed significant changes in 2 of 3 outcome variables: reduced fat mass of 0.802 ± 1.092 kg (P < 0.001), increased lean mass of 0.477 ± 0.966 kg (P < 0.001); minor non-significant increase of 0.007 ± 0.041 kg of bone mass (P = 0.052). The respective changes in BIA measures were a significant reduction of 0.486 ± 1.539 kg fat (P < 0.001), but non-significant increases of 0.084 ± 1.201 kg lean mass (P = 0.425), and 0.014 ± 0.091 kg bone (P = 0.074). Significant, but moderately weak, correlations were seen in absolute mass changes between DXA and BIA: 0.511 (fat), 0.362 (lean) and 0.172 (bone). Compared to DXA, BIA demonstrated mediocre agreement to changes in fat mass, but poor agreement to lean mass changes. BIA significantly underestimated the magnitude of changes in fat and lean mass compared to DXA.
Slanger, W D; Marchello, M J; Busboom, J R; Meyer, H H; Mitchell, L A; Hendrix, W F; Mills, R R; Warnock, W D
1994-06-01
Data of sixty finished, crossbred lambs were used to develop prediction equations of total weight of retail-ready cuts (SUM). These cuts were the leg, sirloin, loin, rack, shoulder, neck, riblets, shank, and lean trim (85/15). Measurements were taken on live lambs and on both hot and cold carcasses. A four-terminal bioelectrical impedance analyzer (BIA) was used to measure resistance (Rs, ohms) and reactance (Xc, ohms). Distances between detector terminals (L, centimeters) were recorded. Carcass temperatures (T, degrees C) at time of BIA readings were also recorded. The equation predicting SUM from cold carcass measurements (n = 53, R2 = .97) was .093 + .621 x weight-.0219 x Rs + .0248 x Xc + .182 x L-.338 x T. Resistance accounted for variability in SUM over and above weight and L (P = .0016). The above equation was used to rank cold carcasses in descending order of predicted SUM. An analogous ranking was obtained from a prediction equation that used weight only (R2 = .88). These rankings were divided into five categories: top 25%, middle 50%, bottom 25%, top 50%, and bottom 50%. Within-category differences in average fat cover, yield grade, and SUM as a percentage of cold carcass weight of carcasses not placed in the same category by both prediction equations were quantified with independent t-tests. These differences were statistically significant for all categories except middle 50%. This shows that BIA located those lambs that could more efficiently contribute to SUM because a higher portion of their weight was lean.
Airway mucosal bioelectric potential difference in cystic fibrosis after lung transplantation.
Wood, A; Higenbottam, T; Jackson, M; Scott, J; Stewart, S; Wallwork, J
1989-12-01
Bioelectrical potential difference (PD) across the respiratory mucosa is raised in cystic fibrosis (CF). We have recorded airway potentials from seven patients with CF who had undergone heart-lung transplantation and from eight patients without CF who had had transplants for cardiovascular disease; comparison of these populations controls for the effects of denervation and immunosuppressive treatment. Six patients without CF who had not had transplants formed an additional control. PD was recorded during routine fiberoptic bronchoscopy, using a Ringer's-perfused exploring bridge connected across a high impedance amplifier to an intravenous reference bridge. Bronchial lavage and sputum culture revealed no evidence of infection. Bronchial PD was similar in all three groups of patients at equivalent sites. However, nasal PD was raised in the CF group (mean value, 44 mV +/- 3.9 SE) compared with the patients who had transplants for cardiovascular disease (mean, 18 mV +/- 1.1 SE), and the control patients (mean, 15 mV +/- 1.2 SE). We conclude that the epithelial defects that result in raised airway potentials in CF do not recur in the transplanted lung.
Perales-García, Aránzazu; Estévez-Martínez, Isabel; Urrialde, Rafael
2016-07-12
Introduction: Hydration is defined as the water intake coming from food and beverages. Its study has become an area by itself, within the nutrition field. Meaning that in 2010 the European Food Safety Authority (EFSA) approved the water intake recommendations, but the study of this topic implies a rigorous methodology, which represents several issues. Objective: Showing as a glance the main methodological issues in hydration studies. Material and methods: Bibliographic revision of scientific literature. Results: The main methodological issues presented are: sample selection (investigation field and sample design), selection of the method to evaluate hydration status (dilution techniques, bioelectrical impedance, plasmatic and urinary indicators, changes in body composition, water losses and clinic symptoms) selection of the method to evaluate water intake (biomarker, questionnaires, informatics programs, smartphone use, 24-h register, dietary history and food frequency questionnaire), and the main sources of hydration. Conclusions: Hydration status should be understood as a routine model, with daily frequency, according to gender, age, physical activity and environmental conditions. Furthermore, the correct design of the methodology has a special importance in order to take into account all the aspects
Electrical impedance characterization of normal and cancerous human hepatic tissue.
Laufer, Shlomi; Ivorra, Antoni; Reuter, Victor E; Rubinsky, Boris; Solomon, Stephen B
2010-07-01
The four-electrode method was used to measure the ex vivo complex electrical impedance of tissues from 14 hepatic tumors and the surrounding normal liver from six patients. Measurements were done in the frequency range 1-400 kHz. It was found that the conductivity of the tumor tissue was much higher than that of the normal liver tissue in this frequency range (from 0.14 +/- 0.06 S m(-1) versus 0.03 +/- 0.01 S m(-1) at 1 kHz to 0.25 +/- 0.06 S m(-1) versus 0.15 +/- 0.03 S m(-1) at 400 kHz). The Cole-Cole models were estimated from the experimental data and the four parameters (rho(0), rho(infinity), alpha, f(c)) were obtained using a least-squares fit algorithm. The Cole-Cole parameters for the cancerous and normal liver are 9 +/- 4 Omega m(-1), 2.2 +/- 0.7 Omega m(-1), 0.5 +/- 0.2, 140 +/- 103 kHz and 50 +/- 28 Omega m(-1), 3.2 +/- 0.6 Omega m(-1), 0.64 +/- 0.04, 10 +/- 7 kHz, respectively. These data can contribute to developing bioelectric applications for tissue diagnostics and in tissue treatment planning with electrical fields such as radiofrequency tissue ablation, electrochemotherapy and gene therapy with reversible electroporation, nanoscale pulsing and irreversible electroporation.
Nutritional evaluation in cirrhosis: Emphasis on the phase angle.
Fernandes, Sabrina Alves; de Mattos, Angelo Alves; Tovo, Cristiane Valle; Marroni, Claudio Augusto
2016-10-18
Protein-calorie malnutrition (PCM) is a common condition in cirrhotic patients, leading to a worse prognosis, complications, poor quality of life and lower survival rates. Among ways of assessing nutritional status, there are anthropometric methods such as the evaluation of the triceps skinfold, the arm circumference, the arm muscle circumference and the body mass index, and non-anthropometric methods such as the subjective global assessment, the handgrip strength of non-dominant hand, and the bioelectrical impedance analysis (BIA). PCM is frequently under-diagnosed in clinical settings in patients with cirrhosis due to the limitations of nutritional evaluation methods in this population. BIA is a useful method, but cannot be indicated in patients with abnormal body composition. In these situations, the phase angle (PA) has been used, and can become an important tool in assessing nutritional status in any situation. The PA is superior to anthropometric methods and might be considered as a nutritional indicator in cirrhosis. The early characterization of the nutritional status in patients with cirrhosis means an early nutritional intervention, with a positive impact on patients' overall prognosis. Among the usually accepted methods for nutritional diagnosis, the PA provides information in a quick and objective manner.
Havinga-Top, A M; Waninge, A; van der Schans, C P; Jager-Wittenaar, H
2015-12-01
Body composition measurements provide important information about physical fitness and nutritional status. People with severe intellectual and visual disabilities (SIVD) have an increased risk for altered body composition. Bioelectrical impedance analysis (BIA) has been evidenced as a reliable and non-invasive method to asses body composition in healthy persons and various patient populations; however, currently, there is no feasible method available to determine body composition in people with SIVD. In this study, therefore, we aimed to assess the feasibility of BIA measurements in persons with SIVD. In 33 participants with SIVD and Gross Motor Functioning Classification System (GMFCS) Scale I, II, III, or IV, two BIA measurements were sequentially performed employing Resistance and Reactance in Ohm and fat-free mass (FFM) in kg as outcome variables, utilizing the Bodystat(®) QuadScan 4000. Feasibility was considered sufficient if ≥ 80% of the first measurement was performed successfully. Agreement between two repeated measurements was determined by using the paired t-test and Intraclass Correlation Coefficient (ICC; two way random, absolute agreement). Bland-Altman analyses were utilized to determine limits of agreement (LOAs) and systematic error. Agreement was considered acceptable if LOAs were <10% of the mean of the first measurement. The first BIA measurements were completed successfully in 88% of the participants. The paired t-test demonstrated no significant differences in Resistance, Reactance, and FFM between BIA Measurements 1 and 2 (P=0.140, 0.091, and 0.866). ICC was 0.965 (95% CI: 0.922-0.984) for Resistance; 0.858 (95% CI: 0.705-0.934) for Reactance; and 0.992 (95% CI: 0.982-0.996) for FFM. LOAs expressed as a percentage of the mean of Measurement 1 were 6.1% for Resistance, 17.6% for Reactance, and 3.8% for FFM. The results of this study suggest that BIA measurements seem to be feasible in persons with SIVD. Although these results require confirmation in a more extensive sample of persons with SIVD, the findings of this study are an important first step in the assessment of applicability of BIA measurements for non-invasive monitoring of physical fitness and nutritional status of persons with SIVD. Copyright © 2015 Elsevier Ltd. All rights reserved.
Franssen, Frits M E; Rutten, Erica P A; Groenen, Miriam T J; Vanfleteren, Lowie E; Wouters, Emiel F M; Spruit, Martijn A
2014-06-01
Low fat-free mass (FFM) is a risk factor for morbidity and mortality in elderly and patient populations. Therefore, measurement of FFM is important in nutritional assessment. Bioelectrical impedance analysis (BIA) is a convenient method to assess FFM and FFM index (FFMI; FFM/height(2)). Although reference values have been established for individuals with normal body weight, no specific cutoff values are available for overweight and obese populations. Also, limited studies accounted for the age-related decline in FFM. To determine BMI- and age-specific reference values for abnormal low FFM(I) in white-ethnic men and women free of self-reported disease from the general population. The UK Biobank is a prospective epidemiological study of the general population from the United Kingdom. Individuals in the age category 45 to 69 years were analyzed. In addition to body weight, FFM and FFMI were measured using a Tanita BC-418MA. Also, self-reported chronic conditions and ethnic background were registered, and lung function was assessed using spirometry. After exclusion of all individuals with missing data, nonwhite ethnicity, self-reported disease, body mass index (BMI) less than 14 or 36 kg/m(2) or higher, and/or an obstructive lung function, reference values for FFM and FFMI were derived from 186,975 individuals (45.9% men; age: 56.9 ± 6.8 years; BMI: 26.5 ± 3.6 kg/m(2); FFMI 18.3 ± 2.4 kg/m(2)). FFM and FFMI were significantly associated with BMI and decreased with age. Percentiles 5, 10, 25, 50, 75, 90, and 95 were calculated for FFM, FFMI, and fat mass (index), after stratification for gender, age, and BMI. Using the UK Biobank dataset, new reference values for body composition assessed with BIA were determined in white-ethnic men and women aged 45 to 69 years. Because these reference values are BMI specific, they are of broad interest for overweight and obese populations. Copyright © 2014 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.
Alves, F D; Souza, G C; Biolo, A; Clausell, N
2014-12-01
The utilisation of bioelectrical impedance analysis (BIA) in heart failure can be affected by many factors and its applicability remains controversial. The present study aimed to verify the adequacy of single-frequency BIA (SF-BIA) and multifrequency BIA (MF-BIA) compared to dual-energy x-ray absorptiometry (DEXA) for evaluating body composition in outpatients with heart failure. In this cross-sectional study, 55 patients with stable heart failure and left ventricle ejection fraction ≤45% were evaluated for fat mass percentage, fat mass and fat-free mass by DEXA and compared with the results obtained by SF-BIA (single frequency of 50 kHz) and MF-BIA (frequencies of 20 and 100 kHz). MF-BIA and DEXA gave similar mean values for fat mass percentage, fat mass and fat-free mass, whereas values from SF-BIA were significantly different from DEXA. Both SF-BIA and MF-BIA measures of body composition correlated strongly with DEXA (r > 0.8; P < 0.001), except for fat mass assessed by SF-BIA, which showed a moderate correlation (r = 0.760; P < 0.001). MF-BIA also showed a better agreement with DEXA by Bland-Altman analysis in all measurements. However, both types of equipment showed wide limits of agreement and a significant relationship between variance and bias (Pitmans's test P > 0.05), except MF-BIA for fat-free mass. Compared with DEXA, MF-BIA showed better accuracy than SF-BIA, although both types of equipment showed wide limits of agreement. The BIA technique should be used with caution, and regression equations might be useful for correcting the observed variations, mainly in extreme values of body composition. © 2014 The British Dietetic Association Ltd.
Hosono, Osamu; Yoshikawa, Noritada; Shimizu, Noriaki; Kiryu, Shigeru; Uehara, Masaaki; Kobayashi, Hiroshi; Matsumiya, Ryo; Kuribara, Akiko; Maruyama, Takako; Tanaka, Hirotoshi
2015-03-01
To determine the availability of bioelectrical impedance analysis (BIA), computed tomography (CT), and magnetic resonance imaging (MRI) for measurement of skeletal muscle mass in patients with rheumatic diseases and quantitatively assess skeletal muscle loss after glucocorticoid (GC) treatment. The data from 22 patients with rheumatic diseases were retrospectively obtained. The muscle mass of body segments was measured with a BIA device in terms of skeletal muscle mass index (SMI). Cross-sectional area (CSA) was obtained from CT and MRI scans at the mid-thigh level using the image analysis program. We further assessed the data of three different measurements before and after GC treatment in 7 patients with rheumatic diseases. SMI of whole body was significantly correlated with estimated muscle volume and mid-thigh muscle CSA with CT and MRI (p < 0.01). Significant correlations between SMI and mid-thigh muscle CSA of each leg were also found (p < 0.01). All the three measurements were negatively correlated with GC dosage (p < 0.01). Significant decline in mid-thigh muscle CSA with CT and MRI was found after GC treatment in 7 patients (p < 0.02). Those patients showed significant decline in SMI of whole body after GC treatment, but not in SMI of each leg. On the other hand, significant correlations between mid-thigh muscle CSA with CT and MRI were found before and after GC treatment (p < 0.01). GC-related skeletal muscle loss could be quantitatively assessed with BIA, CT, or MRI in patients with rheumatic diseases, and CT and MRI appeared to be more accurate than BIA.
Van Puyenbroeck, Karolien; Roelandts, Lieven; Van Deun, Thomas; Van Royen, Paul; Verhoeven, Veronique
2012-01-01
The decline in skeletal muscle in old age is a factor in the development of functional limitations. The objective of this study was to assess if there is a correlation between muscle mass based on bioelectrical impedance analysis (BIA) detection and the fall incidence in nursing home residents and to examine the risk factors for falling in nursing home residents. This prospective cohort study was part of a longitudinal study on nutritional issues in 52 nursing homes in Antwerp (Belgium) from October 2007 to April 2008. Two hundred and seventy-six people aged 65 years and older were included. Each subject was assessed with BIA, the timed get-up-and-go test, the Katz score, the Mini Nutritional Assessment - Short Form and the 36-Item Short Form Health Survey. The primary outcome parameter was fall incidence during the study. The prevalence of sarcopenia varied from 24.3 to 81.5% depending on which definition was used. No association was found between BIA-derived muscle mass and fall incidence. Logistic regression analysis showed that gait speed (odds ratio 1.029; p = 0.003) and mental health (odds ratio 0.981; p = 0.015) are significantly associated with fall incidence in nursing homes. A receiver operating characteristic curve showed that none of the BIA-derived muscle parameters are good predictors of the risk of falling. This study shows that there is no association between sarcopenia based on BIA and fall incidence and that BIA-derived muscle mass has no additional value in predicting fall incidents compared to the timed get-up-and-go test. Copyright © 2012 S. Karger AG, Basel.
Center, S A; Warner, K L; Randolph, J F; Wakshlag, J J; Sunvold, G D
2011-01-01
Resting energy expenditure (REE) approximates ≥60% of daily energy expenditure (DEE). Accurate REE determination could facilitate sequential comparisons among patients and diseases if normalized against lean body mass (LBM). (1) Validate open-flow indirect calorimetry (IC) system and multifrequency bioelectrical impedance analysis (MF-BIA) to determine REE and LBM, respectively, in healthy nonsedated cats of varied body conditions; (2) normalize REE against LBM. Fifty-seven adult neutered domestic short-haired cats with stable BW. Continuous (45-min) IC-measurements determined least observed metabolism REE. Cage gas flow regulated with mass flow controllers was verified using nitrogen dilution; span gases calibrated gas measurements. Respiratory quotient accuracy was verified using alcohol combustion. IC-REE was compared to DEE, determined using doubly labeled water. MF-BIA LBM was validated against criterion references (deuterium, sodium bromide). Intra- and interassay variation was determined for IC and MF-BIA. Mean IC-REE (175 ± 38.7 kcal; 1.5-14% intra- and interassay CV%) represented 61 ± 14.3% of DEE. Best MF-BIA measurements were collected in sternal recumbency and with electrodes in neck-tail configuration. MF-BIA LBM was not significantly different from criterion references and generated LBM interassay CV% of 6.6-10.1%. Over- and underconditioned cats had significantly (P ≤ .05) lower and higher IC-REE (kcal/kg) respectively, compared with normal-conditioned cats. However, differences resolved with REE/LBM (approximating 53 ± 10.3 kcal/LBM [kg]). IC and MF-BIA validated herein reasonably estimate REE and LBM in cats. REE/LBM(kg) may permit comparison of energy utilization in sequential studies or among different cats. Copyright © 2011 by the American College of Veterinary Internal Medicine.
Change with age in regression construction of fat percentage for BMI in school-age children.
Fujii, Katsunori; Mishima, Takaaki; Watanabe, Eiji; Seki, Kazuyoshi
2011-01-01
In this study, curvilinear regression was applied to the relationship between BMI and body fat percentage, and an analysis was done to see whether there are characteristic changes in that curvilinear regression from elementary to middle school. Then, by simultaneously investigating the changes with age in BMI and body fat percentage, the essential differences in BMI and body fat percentage were demonstrated. The subjects were 789 boys and girls (469 boys, 320 girls) aged 7.5 to 14.5 years from all parts of Japan who participated in regular sports activities. Body weight, total body water (TBW), soft lean mass (SLM), body fat percentage, and fat mass were measured with a body composition analyzer (Tanita BC-521 Inner Scan), using segmental bioelectrical impedance analysis & multi-frequency bioelectrical impedance analysis. Height was measured with a digital height measurer. Body mass index (BMI) was calculated as body weight (km) divided by the square of height (m). The results for the validity of regression polynomials of body fat percentage against BMI showed that, for both boys and girls, first-order polynomials were valid in all school years. With regard to changes with age in BMI and body fat percentage, the results showed a temporary drop at 9 years in the aging distance curve in boys, followed by an increasing trend. Peaks were seen in the velocity curve at 9.7 and 11.9 years, but the MPV was presumed to be at 11.9 years. Among girls, a decreasing trend was seen in the aging distance curve, which was opposite to the changes in the aging distance curve for body fat percentage.
Oeffinger, Donna J; Gurka, Matthew J; Kuperminc, Michelle; Hassani, Sahar; Buhr, Neeley; Tylkowski, Chester
2014-05-01
This study assessed the accuracy of measurements of body fat percentage in ambulatory individuals with cerebral palsy (CP) from bioelectrical impedance analysis (BIA) and skinfold equations. One hundred and twenty-eight individuals (65 males, 63 females; mean age 12y, SD 3, range 6-18y) with CP (Gross Motor Function Classification System [GMFCS] levels I (n=6), II (n=46), and III (n=19) participated. Body fat percentage was estimated from (1) BIA using standing height and estimated heights (knee height and tibial length) and (2) triceps and subscapular skinfolds using standard and CP-specific equations. All estimates of body fat percentage were compared with body fat percentage from dual-energy X-ray absorptiometry (DXA) scans. Differences between DXA, BIA, and skinfold body fat percentage were analyzed by comparing mean differences. Agreement was assessed by Bland-Altman plots and concordance correlation coefficients (CCC). BMI was moderately correlated with DXA (Pearson's r=0.53). BIA body fat percentage was significantly different from DXA when using estimated heights (95% confidence intervals [CIs] do not contain 0) but not standing height (95% CI -1.9 to 0.4). CCCs for all BIA comparisons indicated good to excellent agreement (0.75-0.82) with DXA. Body fat percentage from skinfold measurements and CP-specific equations was not significantly different from DXA (mean 0.8%; SD 5.3%; 95% CI -0.2 to 1.7) and demonstrated strong agreement with DXA (CCC 0.86). Accurate measures of body fat percentage can be obtained using BIA and two skinfold measurements (CP-specific equations) in ambulatory individuals with CP. These findings should encourage assessments of body fat in clinical and research practices. © 2013 Mac Keith Press.
Taing, Kevin Y; Farkouh, Michael E; Moineddin, Rahim; Tu, Jack V; Jha, Prabhat
2017-01-01
The utility of bioelectrical impedance analysis (BIA) derived adiposity measures as compared to anthropometric measures for the assessment of adiposity-related health risk is not clear. We aimed to clarify the relationships of BIA and anthropometric derived adipose measures with blood pressure and hypertension, and to compare the discriminative ability of the respective measures for hypertension. We used baseline data collected between 2015 and 2016 from the Indian Study on Health of Adults (ISHA), an ongoing population based cohort study in India ( N = 5990; age 30-69 years). We examined and compared the associations and discriminative ability between anthropometric (body mass index, waist circumference, hip circumference, waist-hip ratio, waist-height ratio) and BIA (whole body and trunk fat percentage) derived adiposity measures with blood pressure components (systolic pressure, diastolic pressure, pulse pressure, mean arterial pressure, mid-blood pressure) and hypertension. Regardless of whether the adiposity measure was derived from BIA or anthropometry, all were strongly and positively associated with blood pressure and hypertension. For both men and women, the magnitude of association of BIA measures with blood pressure and hypertension were comparable to those of anthropometric measures. Further, the ability of BIA derived adiposity measures to distinguish between those with and without hypertension was similar to the discriminative ability of anthropometric measures. As compared to simple anthropometric measures, BIA derived estimates of adiposity provide no apparent advantage in the assessment of blood pressure and hypertension. The observed similarities between adiposity measures suggest that simple anthropometrics may be sufficient to assess adiposity and adiposity-related risks.
Kim, Young Saing; Kim, Eun Young; Kang, Shin Myung; Ahn, Hee Kyung; Kim, Hyung Sik
2017-09-01
Skeletal muscle depletion is an important prognostic factor in patients with chronic obstructive pulmonary disease (COPD); a recent study demonstrated significant correlations between pectoralis muscle area on an axial CT image and COPD-related traits. The purpose of this study was to evaluate the relation between pectoralis muscle areas on CT scans and total body skeletal muscle mass (SMM) in healthy subjects. For 434 subjects that underwent a low-dose chest CT and bioelectrical impedance analysis (BIA) during health screening from January to June of 2014, cross-sectional area of pectoralis muscles were measured in CT scans. Pearson's correlation and multiple linear regression analysis were used to assess the relationship between cross-sectional CT areas of pectoralis muscles and BIA-assessed SMMs. Mean age was 50 ± 10 years (78·8% were male). The mean cross-sectional area of pectoralis muscles was 24·1 cm 2 ± 6·8. A moderate correlation was observed between pectoralis muscle area and BIA-based SMM (r = 0·665, P<0.001). Multivariable analysis showed CT determined pectoralis muscle area was significantly associated with BIA-assessed SMM after adjusting for gender, weight, height and age (β = 0·14 ± 0·02, P<0·001). Cross-sectional area of the pectoralis muscles on single axial CT images shows moderate correlation with total body SMM determined by BIA in healthy subjects. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Xiao, J; Purcell, S A; Prado, C M; Gonzalez, M C
2017-10-06
Low fat-free mass (FFM) or high fat mass (FM) are abnormal body composition phenotypes associated with morbidity. These conditions in combination lead to worse health outcomes, and can be identified by a high FM/FFM ratio. Here, we developed sex, age, and body mass index (BMI) stratified, population-based FM/FFM reference values using bioelectrical impedance analysis (BIA) measurements. White, non-Hispanic individuals aged 18-90 years old with data for weight, stature and BIA resistance measures from the third National Health and Nutrition Examination Survey (NHANES) III were included. Previously validated and sex-specific BIA prediction equations were used to calculate FM and FFM. FM/FFM values were generated at 5th, 50th and 95th percentiles for each sex, age (18-39.9, 40-59.9, 60-69.9 and 70-90 years), and BMI category (underweight, normal weight, overweight, class I/II and class III obesity). A total of 6372 individuals who had estimated FM and FFM values were identified (3366 females, 3006 males). Median values of FM/FFM were 0.24 and 0.40 for young (≤39.9 years) males and females with normal BMI, and 0.34 for males and 0.59 for females who were overweight. For elderly individuals aged >70 years, median FM/FFM for males and females were respectively 0.28 and 0.45 for those with normal BMI, and 0.37 and 0.61 for those in the overweight category. These FM/FFM reference values provide information on body composition characteristics that account for age, sex and BMI, which can be useful to identify individuals at risk for body composition abnormalities. Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Varan, Hacer Dogan; Bolayir, Basak; Kara, Ozgur; Arik, Gunes; Kizilarslanoglu, Muhammet Cemal; Kilic, Mustafa Kemal; Sumer, Fatih; Kuyumcu, Mehmet Emin; Yesil, Yusuf; Yavuz, Burcu Balam; Halil, Meltem; Cankurtaran, Mustafa
2016-12-01
Phase angle (PhA) value determined by bioelectrical impedance analysis (BIA) is an indicator of cell membrane damage and body cell mass. Recent studies have shown that low PhA value is associated with increased nutritional risk in various group of patients. However, there have been only a few studies performed globally assessing the relationship between nutritional risk and PhA in hospitalized geriatric patients. The aim of the study is to evaluate the predictive value of the PhA for malnutrition risk in hospitalized geriatric patients. One hundred and twenty-two hospitalized geriatric patients were included in this cross-sectional study. Comprehensive geriatric assessment tests and BIA measurements were performed within the first 48 h after admission. Nutritional risk state of the patients was determined with NRS-2002. Phase angle values of the patients with malnutrition risk were compared with the patients that did not have the same risk. The independent variables for predicting malnutrition risk were determined. SPSS version 15 was utilized for the statistical analyzes. The patients with malnutrition risk had significantly lower phase angle values than the patients without malnutrition risk (p = 0.003). ROC curve analysis suggested that the optimum PhA cut-off point for malnutrition risk was 4.7° with 79.6 % sensitivity, 64.6 % specificity, 73.9 % positive predictive value, and 73.9 % negative predictive value. BMI, prealbumin, PhA, and Mini Mental State Examination Test scores were the independent variables for predicting malnutrition risk. PhA can be a useful, independent indicator for predicting malnutrition risk in hospitalized geriatric patients.
Nichols, J.; Going, S.; Loftin, M.; Stewart, D.; Nowicki, E.; Pickrel, J.
2007-01-01
The purpose of this study was to compare fat-free mass (FFM) and percent body fat determined by two bio-electrical impedance analysis (BIA) instruments against criterion estimates determined by dual-energy x-ray absorptiometry (DXA) in a multi-racial/ethnic sample of adolescent girls. BIA was assessed in 151 girls (n=51 African-American; n=45 Hispanic; n=55 Caucasian; age 12.2 ± 1.2 yr) using the RJL Quantum II and the American Weights and Measures Body-Comp Scale (BCS). Percent body fat determined by BIA was significantly related to that determined by DXA (R2=0.87, SEE=2.8% for RJL vs DXA, P<0.0001; R2=0.71, SEE=4.4% for BCS vs DXA, P<0.0001). The agreement between DXA and BIA for FFM was also significant (R2=0.91, SEE=0.03 kg for RJL, P <0.0001; R2=0.79, SEE=0.04 kg for BCS, P <0.0001). The BCS overestimated FFM by 2.7 kg (P<0.0001) and underestimated percent body fat by over 4% (P<0.001). There were no differences in percent body fat between DXA and the RJL, and although the RJL significantly overestimated FFM, the absolute difference was <1 kg. Within each ethnic group, the RJL instrument more closely estimated FFM and percent body fat than did the BCS. Although both BIA instruments compared favorably with DXA, the RJL had better stability and accuracy than the BCS, for both the total sample and for the three ethnic groups. Considering its relatively low cost and minimal time required for technical training, BIA is a useful and appropriate technique for assessing body composition in adolescent girls. PMID:17607326
NASA Astrophysics Data System (ADS)
Yerlikaya, Emrah; Karageçili, Hasan; Aydin, Ruken Zeynep
2016-04-01
Obesity is a key risk for the development of hyperglycemia, hypertension, hyperlipidemia, insulin resistance and is totally referred to as the metabolic disorders. Diabetes mellitus, a metabolic disorder, is related with hyperglycemia, altered metabolism of lipids, carbohydrates and proteins. The minimum defining characteristic feature to identify diabetes mellitus is chronic and substantiated elevation of circulating glucose concentration. In this study, it is aimed to determine the body composition analyze of obese and (obese+diabetes) patients.We studied the datas taken from three independent groups with the body composition analyzer instrument. The body composition analyzer calculates body parameters, such as body fat ratio, body fat mass, fat free mass, estimated muscle mass, and base metabolic rate on the basis of data obtained by Dual Energy X-ray Absorptiometry using Bioelectrical Impedance Analysis. All patients and healthy subjects applied to Siirt University Medico and their datas were taken. The Statistical Package for Social Sciences version 21 was used for descriptive data analysis. When we compared and analyzed three groups datas, we found statistically significant difference between obese, (obese+diabetes) and control groups values. Anova test and tukey test are used to analyze the difference between groups and to do multiple comparisons. T test is also used to analyze the difference between genders. We observed the statistically significant difference in age and mineral amount p<0.00 between (diabetes+obese) and obese groups. Besides, when these patient groups and control group were analyzed, there were significant difference between most parameters. In terms of education level among the illiterate and university graduates; fat mass kg, fat percentage, internal lubrication, body mass index, water percentage, protein mass percentage, mineral percentage p<0.05, significant statistically difference were observed. This difference especially may result of a sedentary lifestyle.
Bio-electrical impedance spectroscopy: alternatives for the conventional hand-to-foot measurements.
Cox-Reijven, P L M; Van Kreel, B; Soeters, P B
2002-04-01
Bio-impedance spectroscopy (BIS) is a very attractive method for measuring body composition. The standard method measures impedance from hand to foot. However, in patients a hand or foot is not always accessible. In these cases alternative methods would be helpful. The objective of this study was to compare BIS measurements from hand to foot (HF) with foot to foot (FF) and hand to hand (HH) measurements as alternatives. Aims were firstly, to assess the relationship between resistance (R) values measured by the different methods, secondly, to study the influence of body geometry on this relationship and lastly, to assess the predictive capacity of the methods for measuring body fluid volumes. In 53 subjects with different degrees of obesity (mean BMI = 38; SD = 9 kg/m(2)) three BIS measurements were performed from HF, HH and FF with a Xitron 4000B machine. Resistances of extracellular (Recw) and intracellular water (Ricw) were extrapolated by fitting the data to a Cole-Cole plot. Total body water (TBW) and extracellular water (ECW) were measured by deuterium and bromide dilution respectively. Intracellular water (ICW) was calculated as TBW-ECW. Anthropometric measurements, including length and circumference of limbs and trunk, were performed as measures for body geometry. The Recw, Ricw and R50 values of HF measurements could be accurately described as a function of the Recw, Ricw and R50 values of HH or FF measurements. The relative circumference of arms and legs and the length of the trunk influenced the relationship between R values of the three different measurements. The degree of overweight did not affect this relationship. The precision of the predictions of TBW, ECW and ICW based on R values of the HH measurements were comparable with the traditional HF measurements while the FF measurements gave slightly less accurate results. Under circumstances where total body BIS measurements cannot be performed, FF or HH measurements may be used as alternatives. However, for clinical use the effect of changes in fluid distribution on the accuracy of these methods needs to be studied further. Copyright 2002 Elsevier Science Ltd. All rights reserved.
Wright, C M; Sherriff, A; Ward, S C G; McColl, J H; Reilly, J J; Ness, A R
2008-02-01
(1) To develop a method of manipulating bioelectrical impedance (BIA) that gives indices of lean and fat adjusted for body size, using a large normative cohort of children. (2) To assess the discriminant validity of the method in a group of children likely to have abnormal body composition. Two prospective cohort studies. Normative data: Avon Longitudinal Study of Parents and Children (ALSPAC), population based cohort; proof of concept study: tertiary feeding clinic and special needs schools. Normative data: 7576 children measured aged between 7.25 and 8.25 (mean 7.5) (s.d.=0.2) years; proof of concept study: 29 children with either major neurodisability or receiving artificial feeding, or both, mean age 7.6 (s.d.=2) years. Leg-to-leg (Z (T)) and arm-to-leg (Z (B)) BIA, weight and height. Total body water (TBW) was estimated from the resistance index (RI=height(2)/Z), and fat-free mass was linearly related to TBW. Fat mass was obtained by subtracting fat-free mass from total weight. Fat-free mass was log-transformed and the reciprocal transform was taken for fat mass to satisfy parametric model assumptions. Lean and fat mass were then adjusted for height and age using multiple linear regression models. The resulting standardized residuals gave the lean index and fat index, respectively. In the normative cohort, the lean index was higher and fat index lower in boys. The lean index rose steeply to the middle of the normal range of body mass index (BMI) and then slowly for higher BMI values, whereas the fat index rose linearly through and above the normal range. In the proof of concept study, the children as a group had low lean indices (mean (s.d.) -1.5 (1.7)) with average fat indices (+0.21 (2.0)) despite relatively low BMI standard deviation scores (-0.60 (2.3)), but for any given BMI, individual children had extremely wide ranges of fat indices. The lean index proved more stable and repeatable than BMI. This clinical method of handling BIA reveals important variations in nutritional status that would not be detected using anthropometry alone. BIA used in this way would allow more accurate assessment of energy sufficiency in children with neurodisability and may provide a more valid identification of children at risk of underweight or obesity in field and clinical settings.
Exploring Instructive Physiological Signaling with the Bioelectric Tissue Simulation Engine
Pietak, Alexis; Levin, Michael
2016-01-01
Bioelectric cell properties have been revealed as powerful targets for modulating stem cell function, regenerative response, developmental patterning, and tumor reprograming. Spatio-temporal distributions of endogenous resting potential, ion flows, and electric fields are influenced not only by the genome and external signals but also by their own intrinsic dynamics. Ion channels and electrical synapses (gap junctions) both determine, and are themselves gated by, cellular resting potential. Thus, the origin and progression of bioelectric patterns in multicellular tissues is complex, which hampers the rational control of voltage distributions for biomedical interventions. To improve understanding of these dynamics and facilitate the development of bioelectric pattern control strategies, we developed the BioElectric Tissue Simulation Engine (BETSE), a finite volume method multiphysics simulator, which predicts bioelectric patterns and their spatio-temporal dynamics by modeling ion channel and gap junction activity and tracking changes to the fundamental property of ion concentration. We validate performance of the simulator by matching experimentally obtained data on membrane permeability, ion concentration and resting potential to simulated values, and by demonstrating the expected outcomes for a range of well-known cases, such as predicting the correct transmembrane voltage changes for perturbation of single cell membrane states and environmental ion concentrations, in addition to the development of realistic transepithelial potentials and bioelectric wounding signals. In silico experiments reveal factors influencing transmembrane potential are significantly different in gap junction-networked cell clusters with tight junctions, and identify non-linear feedback mechanisms capable of generating strong, emergent, cluster-wide resting potential gradients. The BETSE platform will enable a deep understanding of local and long-range bioelectrical dynamics in tissues, and assist the development of specific interventions to achieve greater control of pattern during morphogenesis and remodeling. PMID:27458581
Comparison of total body water estimates from O-18 and bioelectrical response prediction equations
NASA Technical Reports Server (NTRS)
Barrows, Linda H.; Inners, L. Daniel; Stricklin, Marcella D.; Klein, Peter D.; Wong, William W.; Siconolfi, Steven F.
1993-01-01
Identification of an indirect, rapid means to measure total body water (TBW) during space flight may aid in quantifying hydration status and assist in countermeasure development. Bioelectrical response testing and hydrostatic weighing were performed on 27 subjects who ingested O-18, a naturally occurring isotope of oxygen, to measure true TBW. TBW estimates from three bioelectrical response prediction equations and fat-free mass (FFM) were compared to TBW measured from O-18. A repeated measures MANOVA with post-hoc Dunnett's Test indicated a significant (p less than 0.05) difference between TBW estimates from two of the three bioelectrical response prediction equations and O-18. TBW estimates from FFM and the Kushner & Schoeller (1986) equation yielded results that were similar to those given by O-18. Strong correlations existed between each prediction method and O-18; however, standard errors, identified through regression analyses, were higher for the bioelectrical response prediction equations compared to those derived from FFM. These findings suggest (1) the Kushner & Schoeller (1986) equation may provide a valid measure of TBW, (2) other TBW prediction equations need to be identified that have variability similar to that of FFM, and (3) bioelectrical estimates of TBW may prove valuable in quantifying hydration status during space flight.
Huang, Ai-Chun; Chen, Yu-Yawn; Chuang, Chih-Lin; Chiang, Li-Ming; Lu, Hsueh-Kuan; Lin, Hung-Chi; Chen, Kuen-Tsann; Hsiao, An-Chi; Hsieh, Kuen-Chang
2015-11-01
Bioelectrical impedance analysis (BIA) is commonly used to assess body composition. Cross-mode (left hand to right foot, Z(CR)) BIA presumably uses the longest current path in the human body, which may generate better results when estimating fat-free mass (FFM). We compared the cross-mode with the hand-to-foot mode (right hand to right foot, Z(HF)) using dual-energy x-ray absorptiometry (DXA) as the reference. We hypothesized that when comparing anthropometric parameters using stepwise regression analysis, the impedance value from the cross-mode analysis would have better prediction accuracy than that from the hand-to-foot mode analysis. We studied 264 men and 232 women (mean ages, 32.19 ± 14.95 and 34.51 ± 14.96 years, respectively; mean body mass indexes, 24.54 ± 3.74 and 23.44 ± 4.61 kg/m2, respectively). The DXA-measured FFMs in men and women were 58.85 ± 8.15 and 40.48 ± 5.64 kg, respectively. Multiple stepwise linear regression analyses were performed to construct sex-specific FFM equations. The correlations of FFM measured by DXA vs. FFM from hand-to-foot mode and estimated FFM by cross-mode were 0.85 and 0.86 in women, with standard errors of estimate of 2.96 and 2.92 kg, respectively. In men, they were 0.91 and 0.91, with standard errors of the estimates of 3.34 and 3.48 kg, respectively. Bland-Altman plots showed limits of agreement of -6.78 to 6.78 kg for FFM from hand-to-foot mode and -7.06 to 7.06 kg for estimated FFM by cross-mode for men, and -5.91 to 5.91 and -5.84 to 5.84 kg, respectively, for women. Paired t tests showed no significant differences between the 2 modes (P > .05). Hence, cross-mode BIA appears to represent a reasonable and practical application for assessing FFM in Chinese populations. Copyright © 2015 Elsevier Inc. All rights reserved.
Body Fat Measurements in Singaporean Adults Using Four Methods
Bi, Xinyan; Loo, Yi Ting
2018-01-01
Few studies have been conducted to measure body composition in Asian populations. In this study, we determined the percent body fat (PBF) by using dual-energy X-ray absorptiometry (DEXA), air-displacement plethysmography (ADP or BOD POD), bioelectrical impedance analysis (BIA) and skinfold (SKF) in 445 healthy Singaporean adults. We observed that the BOD POD, BIA and SKF estimates of PBF were highly correlated with that from DEXA (as a reference method) among Singaporean adults. However, they all underestimated PBF (differences of 3.9% for BOD POD, 5.6% for BIA and 12.5% for SKF). Our results filled a gap in the literature by testing the relationships between DEXA and BOD POD, BIA and SKF in a large sample with a wide range of body mass index (BMI) from 16.1 to 37.5 kg/m2 and age from 21 to 69.2 years. The differences of PBF measured by different methods were dependent on age, gender and ethnicity. No significant difference was observed between DEXA and BOD POD in men aged > 40 or in BMI tertile 3. However, the mean difference between DEXA and BOD POD was significant in women. Different measuring methods of estimating PBF therefore must be cautiously interpreted. PMID:29510545
Buzzell, Paul R; Chamberlain, Valerie M; Pintauro, Stephen J
2002-12-01
This study examined the effectiveness of a series of Web-based, multimedia tutorials on methods of human body composition analysis. Tutorials were developed around four body composition topics: hydrodensitometry (underwater weighing), dual-energy X-ray absorptiometry, bioelectrical impedance analysis, and total body electrical conductivity. Thirty-two students enrolled in the course were randomly assigned to learn the material through either the Web-based tutorials only ("Computer"), a traditional lecture format ("Lecture"), or lectures supplemented with Web-based tutorials ("Both"). All students were administered a validated pretest before randomization and an identical posttest at the completion of the course. The reliability of the test was 0.84. The mean score changes from pretest to posttest were not significantly different among the groups (65.4 plus minus 17.31, 78.82 plus minus 21.50, and 76 plus minus 21.22 for the Computer, Both, and Lecture groups, respectively). Additionally, a Likert-type assessment found equally positive attitudes toward all three formats. The results indicate that Web-based tutorials are as effective as the traditional lecture format for teaching these topics.
Kovarik, Miroslav; Hronek, Miloslav; Zadak, Zdenek
2014-04-01
Lung cancer belongs to the type of tumors with a relatively high frequency of malnutrition, sarcopenia and cachexia, severe metabolic syndromes related to impairment of physical function and quality of life, resistance to therapy and short survival. Inexpensive and accessible methods of evaluating changes in body composition, physical function and nutrition status are for this reason of great importance for clinical practice to enable the early identification, monitoring, preventing and treatment of these nutritional deficiencies. This could lead to improved outcomes in the quality of life, physical performance and survival of patients with lung cancer. The aim of this article is to summarize the recent knowledge for the use of such methods, their predictability for patient outcomes and an association with other clinically relevant parameters, specifically with lung cancer patients, because such an article collectively describing their practical application in clinical practice is lacking. The interest of this article is in the use of anthropometry, handgrip dynamometry, bioelectrical impedance analysis derived phase angle and nutritional screening questionnaires in lung cancer patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Assessment methods in human body composition.
Lee, Seon Yeong; Gallagher, Dympna
2008-09-01
The present study reviews the most recently developed and commonly used methods for the determination of human body composition in vivo with relevance for nutritional assessment. Body composition measurement methods are continuously being perfected with the most commonly used methods being bioelectrical impedance analysis, dilution techniques, air displacement plethysmography, dual energy X-ray absorptiometry, and MRI or magnetic resonance spectroscopy. Recent developments include three-dimensional photonic scanning and quantitative magnetic resonance. Collectively, these techniques allow for the measurement of fat, fat-free mass, bone mineral content, total body water, extracellular water, total adipose tissue and its subdepots (visceral, subcutaneous, and intermuscular), skeletal muscle, select organs, and ectopic fat depots. There is an ongoing need to perfect methods that provide information beyond mass and structure (static measures) to kinetic measures that yield information on metabolic and biological functions. On the basis of the wide range of measurable properties, analytical methods and known body composition models, clinicians and scientists can quantify a number of body components and with longitudinal assessment, can track changes in health and disease with implications for understanding efficacy of nutritional and clinical interventions, diagnosis, prevention, and treatment in clinical settings. With the greater need to understand precursors of health risk beginning in childhood, a gap exists in appropriate in-vivo measurement methods beginning at birth.
Assessment methods in human body composition
Lee, Seon Yeong; Gallagher, Dympna
2009-01-01
Purpose of review The present study reviews the most recently developed and commonly used methods for the determination of human body composition in vivo with relevance for nutritional assessment. Recent findings Body composition measurement methods are continuously being perfected with the most commonly used methods being bioelectrical impedance analysis, dilution techniques, air displacement plethysmography, dual energy X-ray absorptiometry, and MRI or magnetic resonance spectroscopy. Recent developments include three-dimensional photonic scanning and quantitative magnetic resonance. Collectively, these techniques allow for the measurement of fat, fat-free mass, bone mineral content, total body water, extracellular water, total adipose tissue and its subdepots (visceral, subcutaneous, and intermuscular), skeletal muscle, select organs, and ectopic fat depots. Summary There is an ongoing need to perfect methods that provide information beyond mass and structure (static measures) to kinetic measures that yield information on metabolic and biological functions. On the basis of the wide range of measurable properties, analytical methods and known body composition models, clinicians and scientists can quantify a number of body components and with longitudinal assessment, can track changes in health and disease with implications for understanding efficacy of nutritional and clinical interventions, diagnosis, prevention, and treatment in clinical settings. With the greater need to understand precursors of health risk beginning in childhood, a gap exists in appropriate in-vivo measurement methods beginning at birth. PMID:18685451
Davidson, Jeanette; Getz, Majorie
2004-01-01
Nutrition screening is recommended to identify those at risk for malnutrition; nutrition assessment by anthropometry and impedance is widely used to indicate nutritional status but may be problematical in the frail elderly in nursing homes. Acceptability, availability, suitability and appropriate reference data influence clinical application of these measurements. In our study, nutrition screening and assessment methodology were evaluated in 46 nursing home residents, mean age 86.3 +/- 6.6 years, mean weight 66.1 +/- 12.9 kg, mean height 163.1 +/- 9.6 cm, and mean BMI 24.9 +/- 4.6 kg/m2. Significant correlations (P < 0.05) were found in all measures of body weight, BMI, body fatness and leanness. Interpretation of data by five different reference standards and cutoff points revealed wide variation in identification of malnutrition by anthropometry. Appropriate reference data for body lean and fatness are not yet available. Thus, population-specific methodology and reference standards are of crucial importance.
Smith, S; Madden, A M
2016-12-01
The accurate and valid assessment of body composition is essential for the diagnostic evaluation of nutritional status, identifying relevant outcome measures, and determining the effectiveness of current and future nutritional interventions. Developments in technology and our understanding of the influences of body composition on risk and outcome will provide practitioners with new opportunities to enhance current practice and to lead future improvements in practice. This is the second of a two-part narrative review that aims to critically evaluate body composition methodology in diverse adult populations, with a primary focus on its use in the assessment and monitoring of under-nutrition. Part one focused on anthropometric variables [Madden and Smith (2016) J Hum Nutr Diet 29: 7-25] and part two focuses on the use of imaging techniques, bioelectrical impedance analysis, markers of muscle strength and functional status, with particular reference to developments relevant to practice. © 2016 The British Dietetic Association Ltd.
Shiffman, Carl
2017-11-30
To define and elucidate the properties of reduced-variable Nyquist plots. Non-invasive measurements of the electrical impedance of the human thigh. A retrospective analysis of the electrical impedances of 154 normal subjects measured over the past decade shows that 'scaling' of the Nyquist plots for human thigh muscles is a property shared by healthy thigh musculature, irrespective of subject and the length of muscle segment. Here the term scaling signifies the near and sometimes 'perfect' coalescence of the separate X versus R plots into one 'reduced' Nyquist plot by the simple expedient of dividing R and X by X m , the value of X at the reactance maximum. To the extent allowed by noise levels one can say that there is one 'universal' reduced Nyquist plot for the thigh musculature of healthy subjects. There is one feature of the Nyquist curves which is not 'universal', however, namely the frequency f m at which the maximum in X is observed. That is found to vary from 10 to 100 kHz. depending on subject and segment length. Analysis shows, however, that the mean value of 1/f m is an accurately linear function of segment length, though there is a small subject-to-subject random element as well. Also, following the recovery of an otherwise healthy victim of ankle fracture demonstrates the clear superiority of measurements above about 800 kHz, where scaling is not observed, in contrast to measurements below about 400 kHz, where scaling is accurately obeyed. The ubiquity of 'scaling' casts new light on the interpretation of impedance results as they are used in electrical impedance myography and bioelectric impedance analysis.
Longitudinal validity of abdominal adiposity assessment by regional bioelectrical impedance.
Alvero-Cruz, José Ramón; García-Romero, Jerónimo C; Carrillo de Albornoz-Gil, Margarita; Jiménez, Manuel; Correas-Gomez, Lorena; Peñaloza, Piero; López-Fernández, Iván; Carnero, Elvis A
2018-03-20
The main goal of this study was to analyze the longitudinal agreement between changes in trunk and abdominal adiposity variables assessed by DXA and portable bioimpedance device (ViScan). A total of 44 women, enrolled in a 4-month exercise intervention, were included in this analysis. Trunk/abdominal compartments were assessed by ViScan and DXA. Adjusted correlations for age and FM at first assessment (pre) were utilized to perform concurrent validation among methods and completed with an agreement analysis. We observed significant differences between the changes detected by DXA and ViScan for %TFM (difference = -1.41%; p < 0.05), and proportional bias (Kendall's Tau = 0.53; p < 0.0001). Changes in abdominal adiposity were similar (difference = -0.1037 z-score units, p = 0.53), although there was proportional bias (Kendall's Tau = -0.24, p < 0.022). ViScan has a limited capability to evaluated changes in trunk and abdominal adiposity, at least for clinical purposes in adult women.
Modeling the human body shape in bioimpedance vector measurements.
Kim, Chul-Hyun; Park, Jae-Hyeon; Kim, Hyeoijin; Chung, Sochung; Park, Seung-Hun
2010-01-01
Human body shape, called somatotype, has described physique of humans in health and sports applications, relating anthropometric measurements to fatness, muscularity and linearity in a structured way. Here we propose a new method based on bioelectric impedance vector analysis (BIVA) of R/H and Xc/H to represent the cross-sectional area and the body cell mass in a given surface area (m(2)) respectively. Data from six gymnasts, ten dancers, and five fashion models, groups whose physiques and BMI ranges were distinct from one another, were measured for somatotype and BIVA. The models had highest values of the R/H and gymnasts the lowest. Xc/H was lower in models than in the dancers and gymnasts (p < 0.05). Phase angle was lowest in the models and highest in gymnasts significantly (p < 0.05). Pattern analysis from BIVA corresponded to the calculated anthropometric somatotype supporting the hypothesis that BIA's resistance (R) and reactance (Xc) are meaningful discriminates of body size and function which relate to physique in a purposive way.
Obesity and the obesity paradox in heart failure.
Gupta, Pritha P; Fonarow, Gregg C; Horwich, Tamara B
2015-02-01
Obesity has reached epidemic proportions in the general population and is associated with an increased risk for the development of new-onset heart failure (HF). However, in acute and chronic HF, overweight and mild to moderate obesity is associated with substantially improved survival compared with normal weight. This phenomenon has been termed the "obesity paradox" in HF. The majority of data pertaining to the obesity paradox identifies obesity with body mass index; however, the reliability of this method has been questioned. Newer studies have explored the use of other measures of body fat and body composition, including waist circumference, waist-to-hip ratio, skinfold thickness, and bioelectrical impedance analysis of body composition. The relationship between the obesity paradox and cardiorespiratory fitness in HF is also discussed in this review, and we explore the various potential explanations for the obesity paradox and summarize the current evidence and guidelines for intentional weight loss treatments for HF in the obese population. Copyright © 2015 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Nutritional ecology of ursids: A review of newer methods and management implications
Robbins, Charles T.; Schwartz, Charles C.; Felicetti, L.A.
2004-01-01
The capability to understand the nutritional ecology of free-ranging bears has increased dramatically in the last 20 years. Advancements have occurred because (1) managers and biologists recognized the need to link habitat quality, productivity, and variability with bear movements, home ranges, and demographic parameters like reproductive output, survival, and population growth, and (2) several research teams are using new methods to build on the results of earlier field studies. Our ability to couple new field methods and empirical field research with controlled experiments using captive bears has been central to our increased understanding of bear nutrition. Newer methods include the use of stable isotopes to quantify assimilated diet and nutrient flows within ecosystems, bioelectrical impedance to measure body composition, and naturally occurring mercury to estimate fish intake. Controlled experiments using captive bears have been integral to developing methods, isolating specific variables by controlling the environment, and providing additional nutritional understanding necessary to interpret field observations. We review new methods and apply our increased understanding of bear nutritional ecology to 3 management issues: (1) the importance of salmon (Oncorhynchus spp.) to brown bears (Ursus arctos) in the Pacific Northwest, (2) the consequences of the closure of the Yellowstone garbage dumps to grizzly bears, and (3) the relocation of problem bears.
Bioimpedance Identifies Body Fluid Loss after Exercise in the Heat: A Pilot Study with Body Cooling
Gatterer, Hannes; Schenk, Kai; Laninschegg, Lisa; Schlemmer, Philipp; Lukaski, Henry; Burtscher, Martin
2014-01-01
Purpose Assessment of post-exercise changes in hydration with bioimpedance (BI) is complicated by physiological adaptations that affect resistance (R) and reactance (Xc) values. This study investigated exercise-induced changes in R and Xc, independently and in bioelectrical impedance vector analysis, when factors such as increased skin temperature and blood flow and surface electrolyte accumulation are eliminated with a cold shower. Methods Healthy males (n = 14, 24.1±1.7 yr; height (H): 182.4±5.6 cm, body mass: 72.3±6.3 kg) exercised for 1 hr at a self-rated intensity (15 BORG) in an environmental chamber (33°C and 50% relative humidity), then had a cold shower (15 min). Before the run BI, body mass, hematocrit and Posm were measured. After the shower body mass was measured; BI measurements were performed continuously every 20 minutes until R reached a stable level, then hematocrit and Posm were measured again. Results Compared to pre-trial measurements body mass decreased after the run and Posm, Hct, R/H and Xc/H increased (p<0.05) with a corresponding lengthening of the impedance vector along the major axis of the tolerance ellipse (p<0.001). Changes in Posm were negatively related to changes in body mass (r = −0.564, p = 0.036) and changes in Xc/H (r = −0.577, p = 0.041). Conclusions Present findings showed that after a bout of exercise-induced dehydration followed by cold shower the impedance vector lengthened that indicates fluid loss. Additionally, BI values might be useful to evaluate fluid shifts between compartments as lower intracellular fluid loss (changed Xc/R) indicated greater Posm increase. PMID:25279660
Validation of Field Methods to Assess Body Fat Percentage in Elite Youth Soccer Players.
Munguia-Izquierdo, Diego; Suarez-Arrones, Luis; Di Salvo, Valter; Paredes-Hernandez, Victor; Alcazar, Julian; Ara, Ignacio; Kreider, Richard; Mendez-Villanueva, Alberto
2018-05-01
This study determined the most effective field method for quantifying body fat percentage in male elite youth soccer players and developed prediction equations based on anthropometric variables. Forty-four male elite-standard youth soccer players aged 16.3-18.0 years underwent body fat percentage assessments, including bioelectrical impedance analysis and the calculation of various skinfold-based prediction equations. Dual X-ray absorptiometry provided a criterion measure of body fat percentage. Correlation coefficients, bias, limits of agreement, and differences were used as validity measures, and regression analyses were used to develop soccer-specific prediction equations. The equations from Sarria et al. (1998) and Durnin & Rahaman (1967) reached very large correlations and the lowest biases, and they reached neither the practically worthwhile difference nor the substantial difference between methods. The new youth soccer-specific skinfold equation included a combination of triceps and supraspinale skinfolds. None of the practical methods compared in this study are adequate for estimating body fat percentage in male elite youth soccer players, except for the equations from Sarria et al. (1998) and Durnin & Rahaman (1967). The new youth soccer-specific equation calculated in this investigation is the only field method specifically developed and validated in elite male players, and it shows potentially good predictive power. © Georg Thieme Verlag KG Stuttgart · New York.
HOW TO DETERMINE THE NUTRITIONAL STATUS OF PRETERM BABIES?--REVIEW OF THE LITERATURE.
Mól, Nina; Kwinta, Przemko
2015-01-01
Prematurity is a high risk factor threatening the well-being of newborns and their somatic and psychological development in the future. Preterm babies need special medical care in which proper nutrition and metabolic control play an evident role. Our review presents the current knowledge concerning the clinical value of different methods investigated in the neonatal unit setting, including: protein markers of nutritional status (albumin,prealbumin, transferrin, and Retinol Binding Protein (RBP) and hormonal markers of nutritional status (somatomedin C, visfatin and ghrelin). Moreover, there is a discussion of the methods used for evaluating body composition. A variety of different techniques based on the physical properties of organisms was tested on neonates, e.g. the Dual Energy X-ray Absorptiometry (DEXA) method and Bioelectrical Impedance Analysis (BIA). Based on the review of the literature, we can speculate that none of the above methods represents a good single marker of the babies' nutritional status, or a prognostic factor for the future development of premature infants and infants born with IUGR. A combination of several methods from different groups seems to be a promising possibility. It is critical to continue looking for markers that will in a simple and efficient way help to optimize the correct nutritional therapy in infants with IUGR and those who were born prematurely.
Noreik, M; Kuhn, J; Hardenacke, K; Lenartz, D; Bauer, A; Bührle, C P; Häussermann, P; Hellmich, M; Klosterkötter, J; Wiltfang, J; Maarouf, M; Freund, H-J; Visser-Vandewalle, V; Sturm, V; Schulz, R-J
2015-10-01
The progression of Alzheimer's disease (AD) is associated with impaired nutritional status. New methods, such as deep brain stimulation (DBS), are currently being tested to decrease the progression of AD. DBS is an approved method in the treatment of Parkinson's disease, and its suitability for the treatment of AD patients is currently under experimental investigation. To evaluate the advantages and disadvantages of this new treatment, it is important to assess potential side effects of DBS regarding the nucleus basalis of Meynert; this new treatment is thought to positively affect cognition and might counteract the deterioration of nutritional status and progressive weight loss observed in AD. This study aims to assess the nutritional status of patients with AD before receiving DBS of the nucleus basalis of Meynert and after 1 year, and to analyze potential associations between changes in cognition and nutritional status. A 1-year phase I proof-of-concept study. The Department of Psychiatry and Psychotherapy at the University of Cologne. We assessed a consecutive sample of patients with mild to moderate AD (n=6) who fulfilled the inclusion criteria and provided written informed consent. Bilateral low-frequency DBS of the nucleus basalis of Meynert. Nutritional status was assessed using a modified Mini Nutritional Assessment, bioelectrical impedance analysis, a completed 3-day food diary, and analysis of serum levels of vitamin B12 and folate. With a normal body mass index (BMI) at baseline (mean 23.75 kg/m²) and after 1 year (mean 24.59 kg/m²), all but one patient gained body weight during the period of the pilot study (mean 2.38 kg, 3.81% of body weight). This was reflected in a mainly stable or improved body composition, assessed by bioelectrical impedance analysis, in five of the six patients. Mean energy intake increased from 1534 kcal/day (min 1037, max 2370) at baseline to 1736 kcal/day (min 1010, max 2663) after 1 year, leading to the improved fulfillment of energy needs in four patients. The only nutritional factors that were associated with changes in cognition were vitamin B12 level at baseline (Spearman's rho = 0.943, p = 0.005) and changes in vitamin B12 level (Spearman's rho = -0.829, p = 0.042). Patients with AD that received DBS of the nucleus basalis of Meynert demonstrated a mainly stable nutritional status within a 1-year period. Whether DBS is causative regarding these observations must be investigated in additional studies.
The insulation performance of reactive parylene films in implantable electronic devices
Seymour, John P.; Elkasabi, Yaseen; Chen, Hsien-yeh; Lahann, Joerg; Kipke, Daryl R.
2009-01-01
Parylene-C (poly-chloro-p-xylylene) is an appropriate material for use in an implantable, microfabricated device. It is hydrophobic, conformally deposited, has a low dielectric constant, and superb biocompatibility. Yet for many bioelectrical applications, its poor wet adhesion may be an impassable shortcoming. This research contrasts parylene-C and poly(p-xylylene) functionalized with reactive group X (PPX-X) layers using long-term electrical soak and adhesion tests. The reactive parylene was made of complementary derivatives having aldehyde and aminomethyl side groups (PPX-CHO and PPX-CH2NH2 respectively). These functional groups have previously been shown to covalently react together after heating. Electrical testing was conducted in saline at 37°C on interdigitated electrodes with either parylene-C or reactive parylene as the metal layer interface. Results showed that reactive parylene devices maintained the highest impedance. Heat-treated PPX-X device impedance was 800% greater at 10 kHz and 70% greater at 1Hz relative to heated parylene-C controls after 60 days. Heat treatment proved to be critical for maintaining high impedance of both parylene-C and the reactive parylene. Adhesion measurements showed improved wet metal adhesion for PPX-X, which corresponds well with its excellent high frequency performance. PMID:19703712
Implantable electrode for recording nerve signals in awake animals
NASA Technical Reports Server (NTRS)
Ninomiya, I.; Yonezawa, Y.; Wilson, M. F.
1976-01-01
An implantable electrode assembly consisting of collagen and metallic electrodes was constructed to measure simultaneously neural signals from the intact nerve and bioelectrical noises in awake animals. Mechanical artifacts, due to bodily movement, were negligibly small. The impedance of the collagen electrodes, measured in awake cats 6-7 days after implantation surgery, ranged from 39.8-11.5 k ohms at a frequency range of 20-5 kHz. Aortic nerve activity and renal nerve activity, measured in awake conditions using the collagen electrode, showed grouped activity synchronous with the cardiac cycle. Results indicate that most of the renal nerve activity was from postganglionic sympathetic fibers and was inhibited by the baroceptor reflex in the same cardiac cycle.
Pigłowska, Małgorzata; Kostka, Tomasz; Drygas, Wojciech; Jegier, Anna; Leszczyńska, Joanna; Bill-Bielecka, Mirosława; Kwaśniewska, Magdalena
2016-04-27
The purpose of this analysis was to investigate the relationship between body composition, metabolic parameters and endothelial function among physically active healthy middle-aged and older men. Out of 101 asymptomatic men prospectively tracked for traditional cardiovascular risk factors (mean observation period 25.1 years), 55 metabolically healthy individuals who maintained stable leisure time physical activity (LTPA) level throughout the observation and agreed to participate in the body composition assessment were recruited (mean age 60.3 ± 9.9 years). Body composition and raw bioelectrical parameters were measured with bioelectrical impedance analysis (BIA). Microvascular endothelial function was evaluated by means of the reactive hyperemia index (RHI) using Endo-PAT2000 system. Strong correlations were observed between lifetime physical activity (PA), aerobic fitness and most of analyzed body composition parameters. The strongest inverse correlation was found for fat mass (p < 0.01) while positive relationship for fat-free mass (p < 0.01), total body water (p < 0.05 for current aerobic capacity and p < 0.01 for historical PA), body cell mass (p < 0.001), muscle mass (p < 0.001), calcium and potassium (p < 0.01 and p < 0.001 for current aerobic capacity and p < 0.001 and p < 0.01 for historical PA, respectively) and glycogen mass (p < 0.001). Among metabolic parameters, HDL cholesterol (HDL-C) and uric acid were significantly associated with most body composition indicators. Regarding endothelial function, a negative correlation was found for RHI and body mass (p < 0.05) while positive relationship for RHI and body cell mass (p < 0.05), calcium (p < 0.05) and potassium mass (p < 0.05). Impaired endothelial function was observed among 8 subjects. Among bioelectrical parameters, impedance (Z) and resistance (R) normalized for subjects' height were negatively related with body mass, body mass index (BMI) and waist circumference (p < 0.001); while reactance (Xc) normalized for patients' height was negatively related with body mass (p < 0.05). The mean phase angle value was relatively high (8.83 ± 1.22) what reflects a good level of cellularity and cell function. Phase angle was positively related with body mass and BMI (p < 0.05). Both fat mass and muscle mass components are important predictors of metabolic profile. Maintaining regular high PA level and metabolically healthy status through young and middle adulthood may have beneficial influence on body composition parameters and may prevent age-related decrease of fat-free mass and endothelial dysfunction.
Bioelectricity from kitchen and bamboo waste in a microbial fuel cell.
Moqsud, M Azizul; Omine, Kiyoshi; Yasufuku, Noriyuki; Bushra, Quazi S; Hyodo, Masayuki; Nakata, Yukio
2014-02-01
This study evaluated bioelectricity generation by using kitchen garbage (KG) and bamboo waste (BW) as a solid waste management option by a microbial fuel cell (MFC) method. The nutrient content [nitrogen, phosphorus and potassium (NPK)] of the by-products of bioelectricity were also analyzed and assessed for their potential use as a soil amendment. A one-chamber MFC was used for bioelectricity generation in laboratory experiments using both KG and BW. A data-logger recorded voltage every 20 mins at a constant room temperature of 25°C over 45 days. The trend of voltage generation was different for the two organic wastes. In the case of KG, the voltage at the initial stage (0-5 days) increased rapidly and then gradually to a peak of 620 mV. In contrast, the voltage increased gradually to a peak of 540 mV in the case of BW. The by-products of bioelectricity can be used as soil conditioner as its NPK content was in the range of soil conditioner mentioned in other literature. Thus, the MFC has emerged as an efficient and eco-friendly solution for organic waste management, especially in developing and technologically less sophisticated countries, and can provide green and safe electricity from organic waste.
A Bioassay System Using Bioelectric Signals from Small Fish
NASA Astrophysics Data System (ADS)
Terawaki, Mitsuru; Soh, Zu; Hirano, Akira; Tsuji, Toshio
Although the quality of tap water is generally examined using chemical assay, this method cannot be used for examination in real time. Against such a background, the technique of fish bioassay has attracted attention as an approach that enables constant monitoring of aquatic contamination. The respiratory rhythms of fish are considered an efficient indicator for the ongoing assessment of water quality, since they are sensitive to chemicals and can be indirectly measured from bioelectric signals generated by breathing. In order to judge aquatic contamination accurately, it is necessary to measure bioelectric signals from fish swimming freely as well as to stably discriminate measured signals, which vary between individuals. However, no bioassay system meeting the above requirements has yet been established. This paper proposes a bioassay system using bioelectric signals generated from small fish in free-swimming conditions. The system records signals using multiple electrodes to cover the extensive measurement range required in a free-swimming environment, and automatically discriminates changes in water quality from signal frequency components. This discrimination is achieved through an ensemble classification method using probability neural networks to solve the problem of differences between individual fish. The paper also reports on the results of related validation experiments, which showed that the proposed system was able to stably discriminate between water conditions before and after bleach exposure.
Guo, Rongrong; Zhang, Shasha; Xiao, Miao; Qian, Fuping; He, Zuhong; Li, Dan; Zhang, Xiaoli; Li, Huawei; Yang, Xiaowei; Wang, Ming; Chai, Renjie; Tang, Mingliang
2016-11-01
In order to govern cell-specific behaviors in tissue engineering for neural repair and regeneration, a better understanding of material-cell interactions, especially the bioelectric functions, is extremely important. Graphene has been reported to be a potential candidate for use as a scaffold and neural interfacing material. However, the bioelectric evolvement of cell membranes on these conductive graphene substrates remains largely uninvestigated. In this study, we used a neural stem cell (NSC) model to explore the possible changes in membrane bioelectric properties - including resting membrane potentials and action potentials - and cell behaviors on graphene films under both proliferation and differentiation conditions. We used a combination of single-cell electrophysiological recordings and traditional cell biology techniques. Graphene did not affect the basic membrane electrical parameters (capacitance and input resistance), but resting membrane potentials of cells on graphene substrates were more strongly negative under both proliferation and differentiation conditions. Also, NSCs and their progeny on graphene substrates exhibited increased firing of action potentials during development compared to controls. However, graphene only slightly affected the electric characterizations of mature NSC progeny. The modulation of passive and active bioelectric properties on the graphene substrate was accompanied by enhanced NSC differentiation. Furthermore, spine density, synapse proteins expressions and synaptic activity were all increased in graphene group. Modeling of the electric field on conductive graphene substrates suggests that the electric field produced by the electronegative cell membrane is much higher on graphene substrates than that on control, and this might explain the observed changes of bioelectric development by graphene coupling. Our results indicate that graphene is able to accelerate NSC maturation during development, especially with regard to bioelectric evolvement. Our findings provide a fundamental understanding of the role of conductive materials in tuning the membrane bioelectric properties in a graphene model and pave the way for future studies on the development of methods and materials for manipulating membrane properties in a controllable way for NSC-based therapies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Stapel, Sandra N; Looijaard, Wilhelmus G P M; Dekker, Ingeborg M; Girbes, Armand R J; Weijs, Peter J M; Oudemans-van Straaten, Heleen M
2018-05-11
A low bioelectrical impedance analysis (BIA)-derived phase angle (PA) predicts morbidity and mortality in different patient groups. An association between PA and long-term mortality in ICU patients has not been demonstrated before. The purpose of the present study was to determine whether PA on ICU admission independently predicts 90-day mortality. This prospective observational study was performed in a mixed university ICU. BIA was performed in 196 patients within 24 h of ICU admission. To test the independent association between PA and 90-day mortality, logistic regression analysis was performed using the APACHE IV predicted mortality as confounder. The optimal cutoff value of PA for mortality prediction was determined by ROC curve analysis. Using this cutoff value, patients were categorized into low or normal PA group and the association with 90-day mortality was tested again. The PA of survivors was higher than of the non-survivors (5.0° ± 1.3° vs. 4.1° ± 1.2°, p < 0.001). The area under the ROC curve of PA for 90-day mortality was 0.70 (CI 0.59-0.80). PA was associated with 90-day mortality (OR = 0.56, CI: 0.38-0.77, p = 0.001) on univariate logistic regression analysis and also after adjusting for BMI, gender, age, and APACHE IV on multivariable logistic regression (OR = 0.65, CI: 0.44-0.96, p = 0.031). A PA < 4.8° was an independent predictor of 90-day mortality (adjusted OR = 3.65, CI: 1.34-9.93, p = 0.011). Phase angle at ICU admission is an independent predictor of 90-day mortality. This biological marker can aid in long-term mortality risk assessment of critically ill patients.
Margariti, Aikaterini; Kontogianni, Meropi D; Tileli, Nafsika; Georgoulis, Michael; Deutsch, Melanie; Zafeiropoulou, Rodessa; Tiniakos, Dina; Manios, Yannis; Pectasides, Dimitrios; Papatheodoridis, George V
2015-08-01
Abdominal fat is considered to play an important role in nonalcoholic fatty liver disease (NAFLD), although it is not adequately studied because abdominal fat levels cannot be estimated easily. In this study, associations between abdominal obesity, as assessed by abdominal bioelectrical impedance analysis (BIA), and the characteristics of patients with NAFLD were explored. Seventy-four consecutive NAFLD patients who underwent measurement of abdominal fat levels by BIA were included. Levels of abdominal fat 12.5 or less and more than 12.5 were considered to be average and increased, respectively. The mean±SD BMI was 30±4 kg/m and the mean abdominal fat levels were 16±5, whereas 26% of patients had average abdominal fat levels. Patients with average compared with those with increased abdominal fat levels were more frequently women (50 vs. 12%, P=0.001), had lower BMI (27±3 vs. 31±4 kg/m, P<0.001), lower Homeostasis Model Assessment index (2.6±1.4 vs. 3.9±2.7, P=0.045), and lower median liver stiffness on transient elastography (5.3 vs. 6.8 kPa, P=0.025). In patients with available liver biopsy, steatohepatitis was present more frequently in patients with increased compared with average abdominal fat levels (78 vs. 38%, P=0.030) and in patients with BMI 30 or more compared with less than 30 kg/m (87 vs. 48%, P=0.033), but similar in patients with increased or normal waist circumference (67 vs. 56%, P=0.693). Average levels of abdominal fat, as assessed by abdominal BIA, are mainly present in female patients with NAFLD and are associated with a lower degree of insulin resistance. Increased abdominal fat as assessed by BIA and obesity seem to represent strong risk factors for histological steatohepatitis.
Fitness and fatness in relation with attention capacity in European adolescents: The HELENA study.
Cadenas-Sanchez, Cristina; Vanhelst, Jeremy; Ruiz, Jonatan R; Castillo-Gualda, Ruth; Libuda, Lars; Labayen, Idoia; De Miguel-Etayo, Pilar; Marcos, Ascensión; Molnár, Eszter; Catena, Andrés; Moreno, Luis A; Sjöström, Michael; Gottrand, Frederic; Widhalm, Kurt; Ortega, Francisco B
2017-04-01
To examine the association of health-related physical fitness components and accurate measures of fatness with attention in European adolescents. Cross-sectional study. A sub-sample of 444 adolescents from the HELENA study (14.5±1.2years) from 6 different countries participated in this study. Adolescents underwent evaluations of fitness (20m shuttle run, handgrip strength, standing long jump and 4×10m shuttle run tests), fatness (body mass index, skinfold thicknesses, bioelectrical impedance, Bod Pod and dual-energy X-ray absorptiometry) and attention (d2-test). Higher cardiorespiratory fitness was positively associated with better attention capacity (β=0.1, p=0.03). Body mass index and fat mass index measured by Bod Pod and dual-energy X-ray absorptiometry in a subset were negatively associated with attention (β=-0.11, p=0.02; β=-0.36, p=0.02; β=-0.34, p=0.03; respectively). All models were adjusted for age, sex, family-affluence scale and mother education. When these models were additionally adjusted for cardiorespiratory fitness when fatness was the main predictor and vice versa, the associations were somewhat attenuated and were no longer statistically significant. Muscular strength, speed-agility and body fatness markers measured by bioelectrical impedance and skinfolds were not associated with attention. The fit and non-overweight adolescents presented the highest values of attention capacity whilst their unfit and overweight peers showed the lowest values of attention (47.31±2.34 vs. 33.74±4.39; p<0.01). Our results support that both cardiorespiratory fitness and fatness are associated with attention, yet these associations are not independent. A combined effect was also observed, with fit and non-overweight adolescents showing the highest levels of attention and those unfit and overweight the lowest. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Yoo, S; Lee, S-Y; Kim, K-N; Sung, E
2006-07-01
To examine the relationships between body mass index (BMI), percentage-weight-for-height (PWH) and percentage body fat (PBF), and to compare their validity based on PBF with the BMI criteria of International Obesity Task Force (IOTF) for childhood obesity in Korean pre-adolescent school children. Statistical comparative analysis for anthropometric measures. Korean pre-adolescent children (438 boys and 454 girls, aged 8-12 years, mean BMI 19.5+/-3.4 kg/m2). Body mass index and PWH were calculated as body size indices from height and weight. Hand-to-foot bioelectrical impedance analysis (BIA) was performed to obtain PBF values, with obese children defined as PBF above 35%. Sensitivity and specificity were displayed with the gold standard of PBF, and receiver operating characteristic (ROC) curves were used to assess the performance of BMI and PWH in detecting obesity. The prevalence of obesity varied by the criteria: 18.8% by Korean BMI standards for 95 percentile, 11% by the IOTF-BMI 30 kg/m2 and 29.4% by Korean PWH cutoffs. Body mass index and PWH were significantly correlated with PBF after adjusting for age, 0.910 (P<0.01) and 0.915 (P<0.01), respectively. The sensitivity and specificity of the PWH cutoffs were 0.909 and 0.882, respectively. The local BMI 95 percentiles had lower sensitivity (0.714) and specificity (0.790). The IOTF-BMI definition showed much lower sensitivity (0.457) and higher specificity (0.990). The BMI cutoffs corresponding with the highest accuracy were smaller than IOTF-BMI 30 kg/m2 for all age groups in both boys and girls. The prevalence of obesity among Korean pre-adolescent children widely varied according to the diagnostic criteria applied. Universally recommended cutoffs for children by IOTF showed the lowest sensitivity among the criteria used, and may therefore underestimate obesity in this population.
Palle, Stine S; Møllehave, Line T; Taheri-Kadkhoda, Zahra; Johansen, Susanne; Larsen, Lisbeth; Hansen, Janne W; Jensen, Nikolaj K G; Elingaard, Anette O; Møller, Alice H; Larsen, Karen; Andersen, Jens R
2016-12-01
Changes in body composition in cancer patients during chemotherapy are associated with treatment related toxicities or mortalities. Thus, it is relevant to identify accessible, relatively inexpensive, portable and reliable tools for evaluation of body composition in cancer patients during the course of their treatments. To examine relationships between single cross-sectional thighs magnetic resonance imaging (MRI), skeletal muscle mass (SM) as reference and multi-frequency bioelectrical impedance analysis (BIA) fat free mass (FFM) in patients with colorectal cancer undergoing chemotherapy. In an observational, prospective study we examine the relationships between single cross-sectional thighs MRI (T1-weighted (1.5 T) SM compared to FFM BIA (8-electrodes multi-frequency Tanita MC780MA)) and FFM skin-fold thickness (ST) (4-points (Harpenden, Skinfold Caliper)) and SM equation for non-obese persons from Lee et al. 2000 (L2000) (based on age, height, weight, sex and race). FFM and SM (kg) were calculated based on either area (MRI) or weight. 18 CRC patients (10 males and 8 females) with mean (SD) age 67 yr (6) were measured at baseline, and 13 were available for follow-up. BIA overestimated FFM kg for all 31 measurements with mean (SD) 18.0 kg (6.0) compared to the MRI. ST overestimated FFM kg with mean 12.4 kg (6.2) and L2000 underestimated SM kg in 18 measurements and overestimated in 13 with a total mean of -4.3 kg (6.8). BIA and ST were the best alternatives to MRI as they showed constant and thereby correctable errors. The equation, L2000, carried the smallest average measurement error but it was non-constant. Copyright © 2016 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
Santarelli, Simona; Russo, Veronica; Lalle, Irene; De Berardinis, Benedetta; Navarin, Silvia; Magrini, Laura; Piccoli, Antonio; Codognotto, Marta; Castello, Luigi Maria; Avanzi, Gian Carlo; Villacorta, Humberto; Precht, Bernardo Luiz Campanário; de Araújo Porto, Pilar Barreto; Villacorta, Aline Sterque; Di Somma, Salvatore
2017-06-01
Heart failure is a disease characterized by high prevalence and mortality, and frequent rehospitalizations. The aim of this study is to investigate the prognostic power of combining brain natriuretic peptide (BNP) and congestion status detected by bioelectrical impedance vector analysis (BIVA) in acute heart failure patients. This is an observational, prospective, and a multicentre study. BNP assessment was measured upon hospital arrival, while BIVA analysis was obtained at the time of discharge. Cardiovascular deaths were evaluated at 90 days by a follow up phone call. 292 patients were enrolled. Compared to survivors, BNP was higher in the non-survivors group (mean value 838 vs 515 pg/ml, p < 0.001). At discharge, BIVA shows a statistically significant difference in hydration status between survivors and non-survivors [respectively, hydration index (HI) 85 vs 74, p < 0.001; reactance (Xc) 26.7 vs 37, p < 0.001; resistance (R) 445 vs 503, p < 0.01)]. Discharge BIVA shows a prognostic value in predicting cardiovascular death [HI: area under the curve (AUC) 0.715, 95% confidence interval (95% CI) 0.65-0.76; p < 0.004; Xc: AUC 0.712, 95% CI 0.655-0.76, p < 0.007; R: AUC 0.65, 95% CI 0.29-0.706, p < 0.0247]. The combination of BIVA with BNP gives a greater prognostic power for cardiovascular mortality [combined receiving operating characteristic (ROC): AUC 0.74; 95% CI 0.68-0.79; p < 0.001]. In acute heart failure patients, higher BNP levels upon hospital admission, and congestion detected by BIVA at discharge have a significant predictive value for 90 days cardiovascular mortality. The combined use of admission BNP and BIVA discharge seems to be a useful tool for increasing prognostic power in these patients.
Woodrow, Graham
2007-06-01
Complex abnormalities of body composition occur in peritoneal dialysis (PD). These abnormalities reflect changes in hydration, nutrition, and body fat, and they are of major clinical significance. Clinical assessment of these body compartments is insensitive and inaccurate. Frequently, simultaneous changes of hydration, wasting, and body fat content can occur, confounding clinical assessment of each component. Body composition can be described by models of varying complexity that use one or more measurement techniques. "Gold standard" methods provide accurate and precise data, but are not practical for routine clinical use. Dual energy X-ray absorptiometry allows for measurement of regional as well as whole-body composition, which can provide further information of clinical relevance. Simpler techniques such as anthropometry and bioelectrical impedance analysis are suited to routine use in clinic or at the bedside, but may be less accurate. Body composition methodology sometimes makes assumptions regarding relationships between components, particularly in regard to hydration, which may be invalid in pathologic states. Uncritical application of these methods to the PD patient may result in erroneous interpretation of results. Understanding the foundations and limitations of body composition techniques allows for optimal application in clinical practice.
Daghfous, Hafaoua; El Ayeb, Wejdène; Alouane, Leila; Tritar, Fatma
2014-12-01
Malnutrition and cachexia were a frequent problem in lung cancer and increases the risks of morbidity and mortality in these patients. Bioelectrical impedance analysis (BIA) is easy, non-invasive and reproducible method that can be performed. Evaluate nutritional status in patients with primary lung cancer by Mini Nutritional Assessment (MNA), BIA and anthropometric values (weight, arm and calf circumferences) and correlate the nutritional parameters to severity of cancer and histopathology. The nutritional status of 73 cases of primary lung cancer was evaluated by anthropometric parameters, MNA test and impedencemetrie Results: According to body mass index (BMI), malnutrition, overweight and obesity were noted in 34,2%, 13,7% and 5,5%. According to BMI, free-fat mass index (FFMI) and fat mass index (FMI), the investigations occurred malnutrition and depletion of muscle in respectively 19,2% and 23,3% of cases. Fat depletion was noted in 21,9%. Overweight and obesity were detected in 6,8% and 5,5% of cases. Assessment by MNA, revealed that 28,7% of patients were already malnourished and 49,3% of patients were at risk of malnutrition. A significant correlation existed between the score of MNA and arm and calf circumferences, FFMI and FMI. FMI was significantly lower in group of patients with small lung carcinoma. Only FFMI allows early detection of malnutrition in cancer patients overestimated by measuring BMI and arm circumference was the better indicator of depletion of muscle.
Rudolph, G; Bechmann, M; Berninger, T; Kutschbach, E; Held, U; Tornow, R P; Kalpadakis, P; Zol'nikova, I V; Shamshinova, A M
2001-01-01
A new method of multifocal electroretinography making use of scanning laser ophthalmoscope with a wavelength of 630 nm (SLO-m-ERG), evoking short spatial visual stimuli on the retina, is proposed. Algorithm of presenting the visual stimuli and analysis of distribution of local electroretinograms on the surface of the retina is based on short m-sequences. Mathematical cross correlation analysis shows a three-dimensional distribution of bioelectrical activity of the retina in the central visual field. In normal subjects the cone bioelectrical activity is the maximum in the macular area (corresponding to the density of cone distribution) and absent in the blind spot. The method detects the slightest pathological changes in the retina under control of the site of stimulation and ophthalmoscopic picture of the fundus oculi. The site of the pathological process correlates with the topography of changes in bioelectrical activity of the examined retinal area in diseases of the macular area and pigmented retinitis detectable by ophthalmoscopy.
Devakumar, Delan; Grijalva-Eternod, Carlos S; Roberts, Sebastian; Chaube, Shiva Shankar; Saville, Naomi M; Manandhar, Dharma S; Costello, Anthony; Osrin, David; Wells, Jonathan C K
2015-01-01
Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA) is a simple and accurate method for estimating body composition, but requires population-specific calibration equations. Objectives. (1) To generate population specific calibration equations to predict lean mass (LM) from BIA in Nepalese children aged 7-9 years. (2) To explore methodological changes that may extend the range and improve accuracy. Methods. BIA measurements were obtained from 102 Nepalese children (52 girls) using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced. Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R (2) 93%). The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42). Reducing the number of children increased the error at the tails of the weight distribution. Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.
Overweight, Obesity, and Neighborhood Characteristics among Postpartum Latinas
Keller, Colleen; Todd, Michael; Ainsworth, Barbara; Records, Kathryn; Vega-Lopez, Sonia; Permana, Paska; Coonrod, Dean; Nagle Williams, Allison
2013-01-01
Background. Weight gain during the childbearing years and failure to lose pregnancy weight after birth contribute to the development of obesity in Latinas. Design and Methods. Madres para la Salud (Mothers for Health) is a 12-month prospective, randomized controlled trial exploring a social support intervention with moderate-intensity physical activity to effect changes in body fat, systemic and fat tissue inflammation, and depression symptoms in sedentary postpartum Latinas. This paper describes the initial body composition of the sample, social support, and neighborhood contextual correlations of overweight and obese Latina mothers within the first 6 months after birth. Results. The mean body mass index was 29.68 with 38.56% bioelectrical impedence analysis for body fat. Elements of the environment (e.g., opportunities to walk) received middle or high scores. Access to healthy food was positively related to favorability of the walking environment. Waist-to-hip ratio was uncorrelated with other obesity-related indices. Conclusions. The body adiposity of these Latina mothers was coupled with low levels of social support from family and friends and neighborhood characteristics that were unfavorable to walking. PMID:23476752
Hagner-Derengowska, M; Hagner, W; Zubrzycki, Iz; Krakowiak, H; Słomko, W; Dzierżanowski, M; Rakowski, A; Wiącek-Zubrzycka, M
2014-12-01
The somatic build, biological age, general state of health, mental predisposition and physical fitness are the criteria for selection of individuals in competitive sport. The present study aims to analys the differences in body structure and composition of canoeists and kayakers and derive conclusions regarding the criteria for selection of individuals incompetitive sport. The research was conducted on a group of 32 men aged between 17 and 22: 16 kayakers and 16 Canadian canoeists of the junior and teenage Polish national canoeing team. Body composition was examined by means of bioelectrical segmental impedance. Body build type was determined using the anthropometric Heath-Carter method. Statistical analysis was performed using the Welch t-test. The examination of morphological features reveals significant differences in the studied parameters between the canoeists and kayakers. There are also significant differences between competitors of the Sydney 2000 Olympic Games and the studied group. We found that competitive kayakers should be taller than canoeists. The lower part of the body in kayakers is more developed than in canoeists and canoeists are more dehydrated than kayakers.
Pileggi, Vicky Nogueira; Scalize, Antonio Rodolpho Hakime; Camelo, José Simon
2016-01-01
Abstract Objective: To compare the phase angle of patients with osteogenesis imperfecta treated at a tertiary university hospital with patients in a control group of healthy children, and to assess the nutritional status of these patients through the body mass index proposed by the World Health Organization. Methods: Cross-sectional study carried out in a university hospital that included seven patients with osteogenesis imperfecta and a control group of 17 healthy children of the same gender and age. Weight and height were measured and bioelectrical impedance was performed. Subsequently, the phase angle was calculated based on resistance and reactance values. Results: The phase angle of the group of children with osteogenesis imperfecta was significantly lower than that of the control group (p<0.05). The body mass index criterion for age of the World Health Organization showed no difference between groups. Conclusions: Children with osteogenesis imperfecta have a nutritional risk detected by the phase angle, which is a useful tool for nutritional screening. The calculation result could help in the diet therapy of patients with osteogenesis imperfecta. PMID:27102998
Caucasian children's fat mass: routine anthropometry v. air-displacement plethysmography.
Michels, Nathalie; Huybrechts, Inge; Bammann, Karin; Lissner, Lauren; Moreno, Luis; Peeters, Maarten; Sioen, Isabelle; Vanaelst, Barbara; Vyncke, Krishna; De Henauw, Stefaan
2013-04-28
The present paper will use fat mass percentage (FM%) obtained via BOD POD® air-displacement plethysmography (FMADP%) to examine the relative validity of (1) anthropometric measurements/indices and (2) of FM% assessed with equations (FMeq%) based on skinfold thickness and bioelectrical impedance (BIA). In 480 Belgian children (aged 5-11 years) weight, height, skinfold thickness (triceps and subscapular), body circumferences (mid-upper arm, waist and hip), foot-to-foot BIA (Tanita®) and FMADP% were measured. Anthropometric measurements and calculated indices were compared with FMADP%. Next, published equations were used to calculate FMeq% using impedance (equations of Tanita®, Tyrrell, Shaefer and Deurenberg) or skinfold thickness (equations of Slaughter, Goran, Dezenberg and Deurenberg). Both indices and equations performed better in girls than in boys. For both sexes, the sum of skinfold thicknesses resulted in the highest correlation with FMADP%, followed by triceps skinfold, arm fat area and subscapular skinfold. In general, comparing FMeq% with FMADP% indicated mostly an age and sex effect, and an increasing underestimation but less dispersion with increasing FM%. The Tanita® impedance equation and the Deurenberg skinfold equation performed the best, although none of the used equations were interchangeable with FMADP%. In conclusion, the sum of triceps and subscapular skinfold thickness is recommended as marker of FM% in the absence of specialised technologies. Nevertheless, the higher workload, cost and survey management of an immobile device like the BOD POD® remains justified.
Heavens, Kristen R; Charkoudian, Nisha; O'Brien, Catherine; Kenefick, Robert W; Cheuvront, Samuel N
2016-03-01
Few dehydration assessment measures provide accurate information; most are based on reference change values and very few are diagnostically accurate from a single observation or measure. Bioelectrical impedance may lack the precision to detect common forms of dehydration in healthy individuals. Limitations in bioimpedance may be addressed by a unique resistance-reactance (RXc)-score graph method, which transforms vector components into z scores for use with any impedance analyzer in any population. We tested whether the RXc-score graph method provides accurate single or serial assessments of dehydration when compared with gold-standard measures of total body water by using stable isotope dilution (deuterium oxide) combined with body-weight changes. We retrospectively analyzed data from a previous study in which 9 healthy young men participated in 3 trials: euhydration (EUH), extracellular dehydration (ED; via a diuretic), and intracellular dehydration (ID; via exercise in the heat). Participants lost 4-5% of their body weight during the dehydration trials; volume loss was similar between trials (ID compared with ED group: 3.5 ± 0.8 compared with 3.0 ± 0.6 L; P > 0.05). Despite significant losses of body water, most RXc vector scores for ED and ID groups were classified as "normal" (within the 75% population tolerance ellipse). However, directional displacement of vectors was consistent with loss of volume in both ED and ID conditions compared with the EUH condition and tended to be longer in ED than in ID conditions (P = 0.054). We conclude that, whereas individual RXc-score graph values do not provide accurate detection of dehydration from single measurements, directional changes in vector values from serial measurements are consistent with fluid loss for both ED and ID conditions. The RXc-score graph method may therefore alert clinicians to changes in hydration state, which may bolster the interpretation of other recognized change measures of hydration. © 2016 American Society for Nutrition.
Functional and Histological Effects of Chronic Neural Electrode Implantation.
Sahyouni, Ronald; Chang, David T; Moshtaghi, Omid; Mahmoodi, Amin; Djalilian, Hamid R; Lin, Harrison W
2017-04-01
Permanent injury to the cranial nerves can often result in a substantial reduction in quality of life. Novel and innovative interventions can help restore form and function in nerve paralysis, with bioelectric interfaces among the more promising of these approaches. The foreign body response is an important consideration for any bioelectric device as it influences the function and effectiveness of the implant. The purpose of this review is to describe tissue and functional effects of chronic neural implantation among the different categories of neural implants and highlight advances in peripheral and cranial nerve stimulation. Data Sources : PubMed, IEEE, and Web of Science literature search. Review Methods : A review of the current literature was conducted to examine functional and histologic effects of bioelectric interfaces for neural implants. Bioelectric devices can be characterized as intraneural, epineural, perineural, intranuclear, or cortical depending on their placement relative to nerves and neuronal cell bodies. Such devices include nerve-specific stimulators, neuroprosthetics, brainstem implants, and deep brain stimulators. Regardless of electrode location and interface type, acute and chronic histological, macroscopic and functional changes can occur as a result of both passive and active tissue responses to the bioelectric implant. A variety of chronically implantable electrodes have been developed to treat disorders of the peripheral and cranial nerves, to varying degrees of efficacy. Consideration and mitigation of detrimental effects at the neural interface with further optimization of functional nerve stimulation will facilitate the development of these technologies and translation to the clinic. 3.
Characterization of bioelectric potentials
NASA Technical Reports Server (NTRS)
Jorgensen, Charles C. (Inventor); Wheeler, Kevin R. (Inventor)
2004-01-01
Method and system for recognizing and characterizing bioelectric potential or electromyographic (EMG) signals associated with at least one of a coarse gesture and a fine gesture that is performed by a person, and use of the bioelectric potentials to enter data and/or commands into an electrical and/or mechanical instrument. As a gesture is performed, bioelectric signals that accompany the gesture are subjected to statistical averaging, within selected time intervals. Hidden Markov model analysis is applied to identify hidden, gesture-related states that are present. A metric is used to compare signals produced by a volitional gesture (not yet identified) with corresponding signals associated with each of a set of reference gestures, and the reference gesture that is closest to the volitional gesture is identified. Signals representing the volitional gesture are analyzed and compared with a database of reference gestures to determine if the volitional gesture is likely to be one of the reference gestures. Electronic and/or mechanical commands needed to carry out the gesture may be implemented at an interface to control an instrument. Applications include control of an aircraft, entry of data from a keyboard or other data entry device, and entry of data and commands in extreme environments that interfere with accurate entry.
Deminice, R; Rosa, F T; Pfrimer, K; Ferrioli, E; Jordao, A A; Freitas, E
2016-02-01
This study aimed to evaluate changes in total body water (TBW) in soccer athletes using a deuterium oxide dilution method and bioelectrical impedance (BIA) formulas after 7 days of creatine supplementation. In a double-blind controlled manner, 13 healthy (under-20) soccer players were divided randomly in 2 supplementation groups: Placebo (Pla, n=6) and creatine supplementation (CR, n=7). Before and after the supplementation period (0.3 g/kg/d during 7 days), TBW was determined by deuterium oxide dilution and BIA methods. 7 days of creatine supplementation lead to a large increase in TBW (2.3±1.0 L) determined by deuterium oxide dilution, and a small but significant increase in total body weight (1.0±0.4 kg) in Cr group compared to Pla. The Pla group did not experience any significant changes in TBW or body weight. Although 5 of 6 BIA equations were sensitive to determine TBW changes induced by creatine supplementation, the Kushner et al. 16 method presented the best concordance levels when compared to deuterium dilution method. In conclusion, 7-days of creatine supplementation increased TBW determined by deuterium oxide dilution or BIA formulas. BIA can be useful to determine TBW changes promoted by creatine supplementation in soccer athletes, with special concern for formula choice. © Georg Thieme Verlag KG Stuttgart · New York.
Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio
2017-01-17
Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5)) -18 ) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin's concordance correlation coefficient, linear regression, Bland-Altman's agreement analysis, concordance correlation coefficient ( ρc ) and the coefficient of determination ( R ²) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R ² = 0.384, p < 0.001. A paired-sample t -test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = -6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin's concordance correlation coefficient was poor ( ρc = 0.014, 95% CI = -0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels.
Relationship Between Body Fat and Physical Fitness in Army ROTC Cadets.
Steed, Carly L; Krull, Benjamin R; Morgan, Amy L; Tucker, Robin M; Ludy, Mary-Jon
2016-09-01
The Army Physical Fitness Test (APFT), including timed push-ups, sit-ups, and run, assesses physical performance for the Army. Percent body fat is estimated using height and circumference measurements. The objectives of the study were to (a) compare the accuracy of height and circumference measurements to other, more accepted, body fat assessment methods and (b) determine the relationships between body composition and APFT results. Participants included Reserve Officer Training Corps (ROTC) cadets (n = 11 males, 2 females, 21.6 ± 3.5 years) from a midwestern university). At one visit, percent body fat was assessed using height and circumference measurements, air-displacement plethysmography, and bioelectrical impedance analysis. APFT results were provided by the ROTC director. All assessment methods for percent body fat were strongly associated (r ≥ 0.7, p < 0.01), implying that height and circumference measurement is a practical tool to estimate percent body fat of ROTC cadets. Total APFT score was not associated with any body fat assessment method. Push-up number was negatively associated with percent body fat by all assessment methods (r ≥ -0.8, p = 0.001), although run time was positively associated (r ≥ 0.6, p < 0.05). This suggests that percent body fat may be an important variable in determining or improving cardiovascular and muscular endurance, but not APFT performance. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Peña, Adrián F; Doronin, Alexander; Tuchin, Valery V; Meglinski, Igor
2014-08-01
The influence of a low-frequency electric field applied to soft biological tissues ex vivo at normal conditions and upon the topical application of optical clearing agents has been studied by optical coherence tomography (OCT). The electro-kinetic response of tissues has been observed and quantitatively evaluated by the double correlation OCT approach, utilizing consistent application of an adaptive Wiener filtering and Fourier domain correlation algorithm. The results show that fluctuations, induced by the electric field within the biological tissues are exponentially increased in time. We demonstrate that in comparison to impedance measurements and the mapping of the temperature profile at the surface of the tissue samples, the double correlation OCT approach is much more sensitive to the changes associated with the tissues' electro-kinetic response. We also found that topical application of the optical clearing agent reduces the tissues' electro-kinetic response and is cooling the tissue, thus reducing the temperature induced by the electric current by a few degrees. We anticipate that dcOCT approach can find a new application in bioelectrical impedance analysis and monitoring of the electric properties of biological tissues, including the resistivity of high water content tissues and its variations.
Mohan, A; Poulose, R; Kulshreshtha, I; Chautani, A M; Madan, K; Hadda, V; Guleria, R
2017-07-01
The relation between dietary intake and metabolic profile in non-small cell lung cancer (NSCLC) was evaluated. Patients with NSCLC were recruited and their caloric requirement and resting energy expenditure (REE) were calculated using the Harris-Benedict equation and Katch-McArdle formula respectively. Hypermetabolic state was defined as REE more than 10% above the basal metabolic rate (BMR). Body composition parameters were calculated by bioelectric impedance method. The 24-h dietary intake method and Malnutrition Universal Screening Tool assessed nutritional intake. One hundred and forty-eight subjects were included (87% males). Of these, 46.6% subjects were hypermetabolic and 31% cachexic, with lower calorie and protein intakes than recommended, although per cent of total energy derived from protein, fat and carbohydrates were similar. Hypermetabolic patients had lower BMI, though the per cent deficit in energy and protein consumption was similar. Cachexia was associated with lower BMR but not with deficit in energy or protein consumption. No correlation was seen between dietary intake and body composition parameters. The calorie and protein intake of NSCLC patients is lower than recommended. The discordance between elevated REE and dietary intake implies that the relationship between increased energy demands and food intake may be altered. © 2016 John Wiley & Sons Ltd.
Cavity Resonator Wireless Power Transfer System for Freely Moving Animal Experiments.
Mei, Henry; Thackston, Kyle A; Bercich, Rebecca A; Jefferys, John G R; Irazoqui, Pedro P
2017-04-01
The goal of this paper is to create a large wireless powering arena for powering small devices implanted in freely behaving rodents. We design a cavity resonator based wireless power transfer (WPT) system and utilize our previously developed optimal impedance matching methodology to achieve effective WPT performance for operating sophisticated implantable devices, made with miniature receive coils (<8 mm in diameter), within a large volume (dimensions: 60.96 cm × 60.96 cm × 30 cm). We provide unique cavity design and construction methods which maintains electromagnetic performance of the cavity while promoting its utility as a large animal husbandry environment. In addition, we develop a biaxial receive resonator system to address device orientation insensitivity within the cavity environment. Functionality is demonstrated with chronic experiments involving rats implanted with our custom designed bioelectric recording device. We demonstrate an average powering fidelity of 93.53% over nine recording sessions across nine weeks, indicating nearly continuous device operation for a freely behaving rat within the large cavity resonator space. We have developed and demonstrated a cavity resonator based WPT system for long term experiments involving freely behaving small animals. This cavity resonator based WPT system offers an effective and simple method for wirelessly powering miniaturized devices implanted in freely moving small animals within the largest space.
Sevgi, Eser Başak; Erdener, Sefik Evren; Demirci, Mehmet; Topcuoglu, Mehmet Akif; Dalkara, Turgay
2012-01-01
Background Although controversial, paradoxical embolism via patent foramen ovale (PFO) may account for some of the migraine attacks in a subset of migraine with aura (MA) patients. Induction of MA attacks with air bubble injection during transcranial Doppler ultrasound in MA patients with PFO supports this view. It is likely that cerebral embolism in patients with right-to-left shunt induces bioelectrical abnormalities to initiate MA under some conditions. Methods and Results We investigated changes in cerebral bioelectrical activity after intravenous microbubble injection in 10 MA patients with large PFO and right-to-left cardiac shunt. Eight PFO patients without migraine but with large right-to-left shunt and 12 MA patients without PFO served as controls. Four MA patients with PFO were reexamined with sham injections of saline without microbubbles. Bioelectrical activity was evaluated using spectral electroencephalography and, passage of microbubbles through cerebral arteries was monitored with transcranial Doppler ultrasound. Microbubble embolism caused significant electroencephalographic power increase in MA+PFO patients but not in control groups including the sham-injected MA+PFO patients. Headache developed in 2 MA with PFO patients after microbubble injection. Conclusions These findings demonstrate that air microembolism through large PFOs may cause cerebral bioelectrical disturbances and, occasionally, headache in MA patients, which may reflect an increased reactivity of their brain to transient subclinical hypoxia–ischemia, and suggest that paradoxical embolism is not a common cause of migraine but may induce headache in the presence of a large PFO and facilitating conditions. PMID:23316313
Lu, Hsueh-Kuan; Chiang, Li-Ming; Chen, Yu-Yawn; Chuang, Chih-Lin; Chen, Kuen-Tsann; Dwyer, Gregory B.; Hsu, Ying-Lin; Chen, Chun-Hao; Hsieh, Kuen-Chang
2016-01-01
This study aimed to establish a hand-to-hand (HH) model for bioelectrical impedance analysis (BIA) fat free mass (FFM) estimation by comparing with a standing position hand-to-foot (HF) BIA model and dual energy X-ray absorptiometry (DXA); we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women) participated. FFM (FFMDXA) reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland–Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping) were conducted to compare tests of agreement with FFMDXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFMmHH = 0.537 h2/ZHH − 0.126 year + 0.217 weight + 18.235 (r2 = 0.919, standard estimate of error (SEE) = 2.164 kg, n = 269). The mean validated correlation coefficients and limits of agreement (LOAs) of the Bland–Altman analysis of the calculated values for FFMmHH and FFMDXA were 0.958 and −4.369–4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFMmHF) and FFMDXA were 0.958 and −4.356–4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFMFHH = 0.615 h2/ZHH − 0.144 year + 0.132 weight + 16.507 (r2 = 0.870, SEE = 1.884 kg, n = 201); the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFMFHH and FFMDXA) were 0.929 and −3.880–3.886 kg, respectively. The FFMHF and FFMDXA were 0.942 and −3.511–3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM. PMID:27775642
Lu, Hsueh-Kuan; Chiang, Li-Ming; Chen, Yu-Yawn; Chuang, Chih-Lin; Chen, Kuen-Tsann; Dwyer, Gregory B; Hsu, Ying-Lin; Chen, Chun-Hao; Hsieh, Kuen-Chang
2016-10-21
This study aimed to establish a hand-to-hand (HH) model for bioelectrical impedance analysis (BIA) fat free mass (FFM) estimation by comparing with a standing position hand-to-foot (HF) BIA model and dual energy X-ray absorptiometry (DXA); we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women) participated. FFM (FFM DXA ) reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland-Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping) were conducted to compare tests of agreement with FFM DXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFM m HH = 0.537 h²/Z HH - 0.126 year + 0.217 weight + 18.235 ( r ² = 0.919, standard estimate of error (SEE) = 2.164 kg, n = 269). The mean validated correlation coefficients and limits of agreement (LOAs) of the Bland-Altman analysis of the calculated values for FFM m HH and FFM DXA were 0.958 and -4.369-4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFM m HF ) and FFM DXA were 0.958 and -4.356-4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFM F HH = 0.615 h²/Z HH - 0.144 year + 0.132 weight + 16.507 ( r ² = 0.870, SEE = 1.884 kg, n = 201); the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFM F HH and FFM DXA ) were 0.929 and -3.880-3.886 kg, respectively. The FFM HF and FFM DXA were 0.942 and -3.511-3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM.
Santarelli, Simona; Russo, Veronica; Lalle, Irene; De Berardinis, Benedetta; Vetrone, Francesco; Magrini, Laura; Di Stasio, Enrico; Piccoli, Antonio; Codognotto, Marta; Mion, Monica M; Castello, Luigi M; Avanzi, Gian Carlo; Di Somma, Salvatore
2017-06-01
The objective of this study was to investigate the prognostic role of quantitative reduction of congestion during hospitalization assessed by Bioelectrical Impedance Vector Analysis (BIVA) serial evaluations in patients admitted for acute heart failure (AHF). AHF is a frequent reason for patients to be admitted. Exacerbation of chronic heart failure is linked with a progressive worsening of the disease with increased incidence of death. Fluid overload is the main mechanism underlying acute decompensation in these patients. BIVA is a validated technique able to quantify fluid overload. a prospective, multicentre, observational study in AHF and no AHF patients in three Emergency Departments centres in Italy. Clinical data and BIVA evaluations were performed at admission (t0) and discharge (tdis). A follow-up phone call was carried out at 90 days. Three hundred and thirty-six patients were enrolled (221 AHF and 115 no AHF patients). We found that clinical signs showed the most powerful prognostic relevance. In particular the presence of rales and lower limb oedema at tdis were linked with events relapse at 90 days. At t0, congestion detected by BIVA was observed only in the AHF group, and significantly decreased at tdis. An increase of resistance variation (dR/H) >11 Ω/m during hospitalization was associated with survival. BIVA showed significant results in predicting total events, both at t0 (area under the curve (AUC) 0.56, p<0.04) and at tdis (AUC 0.57, p<0.03). When combined with clinical signs, BIVA showed a very good predictive value for cardiovascular events at 90 days (AUC 0.97, p<0.0001). In AHF patients, an accurate physical examination evaluating the presence of rales and lower limbs oedema remains the cornerstone in the management of patients with AHF. A congestion reduction, obtained as a consequence of therapies and detected through BIVA analysis, with an increase of dR/H >11 Ω/m during hospitalization seems to be associated with increased 90 day survival in patients admitted for AHF.
Silva, Danilo R P; Ribeiro, Alex S; Pavão, Fernando H; Ronque, Enio R V; Avelar, Ademar; Silva, Analiza M; Cyrino, Edilson S
2013-01-01
To analyze the validity of methods to assess body fat in children and adolescents using a systematic review. The search was conducted by two independent researchers using the MEDLINE, BioMed Central, SciELO and LILACS electronic databases. For inclusion, the articles should be written in English or Portuguese, and must have used multi-compartment models as the criterion measure of the model, with body fat measurement of whole body in non-athlete children and adolescents. A preliminary search resulted in 832 studies. After all selection steps were performed, 12 articles were included. The selected studies were published between 1997 and 2010, whose samples consisted of children and adolescents with levels of relative body fat ranging from 20.7% to 41.4%. The methods used were: dual energy X-ray absorptiometry (58.3%), isotope dilution (41.6%), skinfold thickness (33.3%), hydrostatic weighing (25%), bioelectrical impedance analysis (25%), air displacement plethysmography (16.6%), and total body electrical conductivity (8.3%). Based on the analysis of the studies, isotope dilution and air displacement plethysmography methods were the most reliable, despite the limited number of studies. As for clinical use or for population-based studies, the equation of Slaughter et al. (1998), which uses the triceps and subscapular skinfolds thickness, showed the best results for assessment of body fat in this population. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.
Some features of the bioelectric activity of the muscles with prolonged hypokinesia
NASA Technical Reports Server (NTRS)
Belaya, N. A.; Amirov, R. Z.; Shaposhnikov, Y. A.; Lebedeva, I. P.; Sologub, B. S.
1978-01-01
The effects of prolonged hypokinesia, brought on by confinement to bed and the attendant lack of motor activity, on the bioelectric activity of muscles are studied. Electromyographic measurements of amplitude and frequency indicators of muscular bioelectric activity were analyzed.
Levin, Michael; Pezzulo, Giovanni; Finkelstein, Joshua M
2017-06-21
Living systems exhibit remarkable abilities to self-assemble, regenerate, and remodel complex shapes. How cellular networks construct and repair specific anatomical outcomes is an open question at the heart of the next-generation science of bioengineering. Developmental bioelectricity is an exciting emerging discipline that exploits endogenous bioelectric signaling among many cell types to regulate pattern formation. We provide a brief overview of this field, review recent data in which bioelectricity is used to control patterning in a range of model systems, and describe the molecular tools being used to probe the role of bioelectrics in the dynamic control of complex anatomy. We suggest that quantitative strategies recently developed to infer semantic content and information processing from ionic activity in the brain might provide important clues to cracking the bioelectric code. Gaining control of the mechanisms by which large-scale shape is regulated in vivo will drive transformative advances in bioengineering, regenerative medicine, and synthetic morphology, and could be used to therapeutically address birth defects, traumatic injury, and cancer.
Clegg, John P; Guest, Julian F
2007-04-01
To estimate the cost-utility of bio-electric stimulation therapy (Posifect) compared to standard care in elderly patients with chronic, non-healing wounds of > 6 months duration, from the perspective of the National Health Service (NHS) in the UK. Clinical and resource use data from a 16 week clinical evaluation of bio-electric stimulation therapy among patients who had recalcitrant wounds were combined with utility data obtained from a standard gamble analysis to construct a 16 week Markov model. The model considers the decision by a clinician to continue with a patient's previous care plan or treat with bio-electric stimulation therapy. Unit resource costs at 2005/2006 prices were applied to the resource utilisation estimates within the model, enabling the cost-utility of bio-electric stimulation therapy compared to standard care to be estimated. The acquisition cost of Posifect had not been decided at the time of performing this study. Hence, the base case analysis used a cost of 50 pounds per dressing. 33% of all wounds are expected to heal within 16 weeks after the start of bio-electric stimulation therapy. Consequently, using bio-electric stimulation therapy is expected to lead to a 51% decrease in the number of domiciliary clinician visits, from 4.7 to 2.3 per week. The model also showed that using bio-electric stimulation therapy instead of patients' standard care is expected to reduce the NHS cost of managing them by 16% from 2287 pounds (95% CI: 1838 pounds; 2735 pounds) to 1921 pounds (95% CI: 1609 pounds; 2233 pounds) and result in a health gain of 0.023 QALYs over 16 weeks. Hence, bio-electric stimulation therapy was found to be a dominant treatment. Sensitivity analyses demonstrated that the cost-utility of using bio-electric stimulation therapy relative to standard care is very sensitive to the acquisition cost of the therapy, the acquisition cost of patients' drugs and the number of clinician visits and less sensitive to utility values and the acquisition cost of other dressings. Within the limitations of the model, bio-electric stimulation therapy is expected to afford the NHS a cost-effective dressing compared to standard care in the management of chronic non-healing wounds of > 6 months duration. Bio-electric stimulation therapy's acquisition cost is expected to be offset by a reduction in the requirement for domiciliary clinician visits, leading to a release of NHS resources for use elsewhere in the system, thereby generating an increase in NHS efficiency.
Mainenti, Míriam Raquel Meira; Felicio, Lilian Ramiro; Rodrigues, Erika de Carvalho; Ribeiro da Silva, Dalila Terrinha; Vigário Dos Santos, Patrícia
2014-04-01
[Purpose] Complaint of pain is common in computer workers, encouraging the investigation of pain-related workplace factors. This study investigated the relationship among work-related characteristics, psychosocial factors, and pain among computer workers from a university center. [Subjects and Methods] Fifteen subjects (median age, 32.0 years; interquartile range, 26.8-34.5 years) were subjected to measurement of bioelectrical impedance; photogrammetry; workplace measurements; and pain complaint, quality of life, and motivation questionnaires. [Results] The low back was the most prevalent region of complaint (76.9%). The number of body regions for which subjects complained of pain was greater in the no rest breaks group, which also presented higher prevalences of neck (62.5%) and low back (100%) pain. There were also observed associations between neck complaint and quality of life; neck complaint and head protrusion; wrist complaint and shoulder angle; and use of a chair back and thoracic pain. [Conclusion] Complaint of pain was associated with no short rest breaks, no use of a chair back, poor quality of life, high head protrusion, and shoulder angle while using the mouse of a computer.
The quantification of body fluid allostasis during exercise.
Tam, Nicholas; Noakes, Timothy D
2013-12-01
The prescription of an optimal fluid intake during exercise has been a controversial subject in sports science for at least the past decade. Only recently have guidelines evolved from 'blanket' prescriptions to more individualised recommendations. Currently the American College of Sports Medicine advise that sufficient fluid should be ingested to ensure that body mass (BM) loss during exercise does not exceed >2 % of starting BM so that exercise-associated medical complications will be avoided. Historically, BM changes have been used as a surrogate for fluid loss during exercise. It would be helpful to accurately determine fluid shifts in the body in order to provide physiologically appropriate fluid intake advice. The measurement of total body water via D2O is the most accurate measure to detect changes in body fluid content; other methods, including bioelectrical impedance, are less accurate. Thus, the aim of this review is to convey the current understanding of body fluid allostasis during exercise when drinking according to the dictates of thirst (ad libitum). This review examines the basis for fluid intake prescription with the use of BM, the concepts of 'voluntary and involuntary dehydration' and the major routes by which the body gains and loses fluid during exercise.
Mupere, Ezekiel; Zalwango, Sarah; Chiunda, Allan; Okwera, Alphonse; Mugerwa, Roy; Whalen, Christopher
2009-01-01
Purpose We determined whether human immunodeficiency virus (HIV) infection affects body cell mass and fat mass wasting among adults with pulmonary tuberculosis (PTB). Methods We screened 967 Ugandan adults for PTB and HIV infection in a cross-sectional study. We compared anthropometric and bioelectric impedance analysis (BIA) body composition parameters among HIV-seropositive and HIV-seronegative men and women with or without PTB using a non-parametric test. Results We found that poor nutritional status associated with TB differed among men and women. Anthropometric and BIA body composition did not differ between HIV-seropositive and HIV-seronegative patients regardless of gender. Average weight group difference in men comprised of body cell mass and fat mass in equal proportions of 43%. In women, average weight group difference comprised predominantly of fat mass of 73% and body cell mass of 13%. Compared to individuals without TB, patients with TB had lower body mass index, weight, body cell mass, and fat mass regardless of gender and HIV status. Conclusions Gender but not HIV status was associated with body composition changes in TB. Tuberculosis appears to be the dominant factor driving the wasting process among co-infected patients. PMID:20159491
Jo, Garam; Rossow-Kimball, Brenda; Lee, Yongho
2018-04-01
The current study examined the effects of an exercise program on health related physical fitness, self-efficacy, and physical activity levels in adults with intellectual disability. The study used pre- and posttest experimental research design with a control group. Total of 23 adults with intellectual disability were recruited with 12 assigned for the exercise group and 11 for the control group, separately. The measures of health related physical fitness included cardio pulmonary endurance (step-test), body composition (bioelectrical impedance analysis), flexibility (sit and reach), muscle endurance (sit-up), and strength (hand grip strength). Self-efficacy was measured using the physical self-efficacy scale. Accelerometers were used to measure physical activity levels. All variables were measured and evaluated twice at baseline and at the end of the program. The exercise program consisted of band exercises and rhythmic activity for 90 min, twice per week for 12 weeks. After the intervention, significant improvements were found in the experimental group in muscle endurance, self-efficacy, and physical activity levels. An exercise program may be recommended as a nonpharmaceutical method to improve the health of adults with intellectual disabilities.
Rafizadeh-Tafti, Saeed; Haqiqatkhah, Mohammad Hossein; Saviz, Mehrdad; Janmaleki, Mohsen; Faraji Dana, Reza; Zanganeh, Somayeh; Abdolahad, Mohammad
2017-01-01
A highly sensitive impedimetric bio-chip based on vertically aligned multiwall carbon nanotubes (VAMWCNTs), was applied in direct interaction with lung cancer cells. Our tool provided both inducing and monitoring the bioelectrical changes in the cells initiated by electromagnetic (EM) wave stimulation. EM wave of 940MHz frequency with different intensities was used. Here, wave ablation might accumulate electrical charge on the tips of nanotubes penetrated into cell's membrane. The charge might induce ionic exchanges into the cell and cause alterations in electrical states of the membrane. Transmembrane electrostatic/dynamic states would be strongly affected due to such exchanges. Our novel modality was that, the cells' vitality changes caused by charge inductions were electrically detected with the same nanotubes in the architecture of electrodes for impedance measurement. The responses of the sensor were confirmed by electron and florescent microscopy images as well as biological assays. In summation, our method provided an effective biochip for enhancing and detecting external EM stimulation on the cells useful for future diagnostic and therapeutic applications, such as wave-guided drug-resistance breakage. Copyright © 2016 Elsevier B.V. All rights reserved.
Role of bioimpedance vectorial analysis in cardio-renal syndromes.
Aspromonte, Nadia; Cruz, Dinna N; Ronco, Claudio; Valle, Roberto
2012-01-01
The cardio-renal syndromes (CRS) are the result of complex bidirectional organ cross-talk between the heart and kidney, with tremendous overlap of diseases such as coronary heart disease, heart failure (HF), and renal dysfunction in the same patient. Volume overload plays an important role in the pathophysiology of CRS. The appropriate treatment of overhydration, particularly in HF and in chronic kidney disease, has been associated with improved outcomes and blood pressure control. Clinical examination alone is often insufficient for accurate assessment of volume status because significant volume overload can exist even in the absence of peripheral or pulmonary edema on physical examination or radiography. Bioelectrical impedance techniques increasingly are being used in the management of patients with HF and those on chronic dialysis. These methods provide more objective estimates of volume status in such patients. Used in conjunction with standard clinical assessment and biomarkers such as the natriuretic peptides, bioimpedance analysis may be useful in guiding pharmacologic and ultrafiltration therapies and subsequently restoring such patients to a euvolemic or optivolemic state. In this article, we review the use of these techniques in CRS. Copyright © 2012 Elsevier Inc. All rights reserved.
Does intra-abdominal fluid increase the resting energy expenditure?
Zarling, E J; Grande, A; Hano, J
1997-10-01
In patients with intra-abdominal fluid collection, caloric needs are based on an estimated dry weight. This is done because intra-abdominal fluid has been assumed to be metabolically inactive. One recent study of patients with slowly resolving ascites suggested otherwise. In our study, the effect of intra-abdominal fluid on the resting energy expenditure (REE) and apparent lean body mass was determined in 10 stable patients requiring peritoneal dialysis. For each subject, in both the empty and full state, we measured REE by indirect calorimetry, and body composition by the bioelectric impedance method. In the full state, the VCO2 was significantly increased (210 +/- 11 versus 197 +/- 9 mL/min, P < 0.02) compared with the empty state. This caused an increase in the calculated resting energy expenditure (1531 +/- 88 kcal/d empty versus 1593 +/- 94 kcal/d full, P < 0.05). The magnitude of increase in REE was similar to the expected calories derived from glucose absorbed out of the dialysate. Estimates of body fat, lean body mass, and total water also were not affected by the intra-abdominal fluid. We conclude that intra-abdominal fluid will not affect the measured REE and hence may be considered to be metabolically inactive.
Percentile curves for body fatness and cut-offs to define malnutrition in Russians
NASA Astrophysics Data System (ADS)
Nikolaev, D. V.; Rudnev, S. G.; Starunova, O. A.; Eryukova, T. A.; Kolesnikov, V. A.; Ponomareva, E. G.; Soboleva, N. P.; Sterlikov, S. A.
2013-04-01
Here, we report first results of the large-scale ongoing bioelectrical impedance body composition study in Russians. By the end of 2012, 216 out of 800 Russian Health Centres submitted raw bioimpedance data on 844,221 adults and children aged 5-80 years, representing nearly 0.6% of the Russian population, who were accessed cross-sectionally using the same type of bioimpedance meter, ABC-01 Medas. Estimates of overweight, obesity, and normal weight obesity prevalence in the general population, as well as characteristics of diagnostic sensitivity and specificity of the conventional WHO BMI-based criteria of obesity depending on age are obtained. The smoothed reference centile curves for percentage fat mass are constructed, and localized cut-offs for fatness and thinness are provided that can be used both at the individual and epidemiological levels.
Molina-García, Javier; Castillo, Isabel; Pablos, Carlos; Queralt, Ana
2009-04-01
The objective of this cross-sectional study was to analyze the relation of Body Mass Index with body fat mass while taking into account the amount of leisure-time physical activity for 299 male university students. Body fat mass was measured by bioelectrical impedance analysis. An estimation of energy expenditure in leisure-time physical activity in metabolic equivalents (METs) was obtained so participants were divided into six activity groups by percentile: no physical activity by the first group and participants physically active were divided into five groups by percentiles: < 25%, 26-50%, 51-75%, 76-90%, and 91-100%. Correlations of Body Mass Index with body fat mass were strong in different groups-values ranged from .76 to .85, except for the > 90% group.
Physical activity and self-efficacy in normal and over-fat children.
Suton, Darijan; Pfeiffer, Karin A; Feltz, Deborah L; Yee, Kimbo E; Eisenmann, Joey C; Carlson, Joseph J
2013-09-01
To examine the independent and combined association of self-efficacy and fatness with physical activity in 5(th) grade children. Participants were 281 students (10.4 ± 0.7 years). Physical activity was assessed using a self-report question. Self-efficacy to be physically active was assessed using a 5-point scale. Body fatness was assessed by bioelectrical impedance. Descriptive statistics, ANOVA, and t-tests were used. There were no differences in reported days of physical activity between boys and girls, and normal-fat and over-fat children. However, children with high self-efficacy participated in significantly more physical activity compared to their low self-efficacy counterparts (3.4 ± 2.0 days vs. 5.4 ± 1.8 days, respectively, p < .001). Only physical activity self-efficacy was related to physical activity, fatness was not.
A comparison of field methods to assess body composition in a diverse group of sedentary women.
D'Alonzo, Karen T; Aluf, Ana; Vincent, Linda; Cooper, Kristin
2009-01-01
Accurate assessment of body composition is essential in the evaluation of obesity. While laboratory methods are commonly used to assess fat mass, field measures (e.g., skinfold thickness [SKF] and bioelectrical impedance [BIA]) may be more practical for screening large numbers of individuals in intervention studies. In this study, a correlational design was used among 46 racially and ethnically diverse, sedentary women (mean age = 25.73 years) to (a) compare the percentage of body fat as determined by SKF and the upper body BIA and (b) examine the effects of body mass index (BMI), racial/ethnic background, age, and stage of the menstrual cycle on differences in the estimated percentage of body fat obtained using the SKF and BIA. Overall, a significant correlation between SKF and BIA (r = .98, p < .001) was found, with similar findings among Black, Hispanic and White non-Hispanic women. The mean differences between BIA and SKF were not significantly correlated with BMI, age, race/ethnicity or stage of the menstrual cycle. Data from this study suggest that BIA showed similar body fat prediction values compared with SKF and may be a viable alternative to SKF among diverse groups of healthy women. Additional testing and comparison of these field methods with the laboratory methods of hydro-densitometry or dual energy X-ray absorptiometry is recommended to further determine whether BIA devices can be routinely recommended as an alternative to the SKF.
Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio
2017-01-01
Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5))−18) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin’s concordance correlation coefficient, linear regression, Bland–Altman’s agreement analysis, concordance correlation coefficient (ρc) and the coefficient of determination (R2) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R2 = 0.384, p < 0.001. A paired-sample t-test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = −6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin’s concordance correlation coefficient was poor (ρc = 0.014, 95% CI = −0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels. PMID:28106719
Słupska, Lucyna; Paprocka-Borowicz, Małgorzata; Taradaj, Jakub; Bidzińska, Gabriela; Marczyński, Daniel; Cynarska, Aleksandra; Rosińczuk, Joanna
2015-01-01
Kinesio taping (KT) may be a new treatment in patients with myofascial trigger points (MTrPs). A new method available for taping practitioners is cross taping (CT). The main objective was to determine how CT, KT, and medical adhesive tape (sham group) affect the subjective assessment of resting bioelectrical activity and pain of the upper trapezius muscle (UT) in patients with MTrPs. 105 volunteers were recruited to participate. The primary outcome was resting bioelectrical activity of UT muscle as assessed by surface electromyography (sEMG) in each group and pain intensity on a visual analog scale (VAS). Assessments were collected before and after intervention and after the 24-hours follow-up. No significant differences were observed in bioelectrical activity of UT between pre-, post-, and follow-up results. In three groups patients had significantly lower pain VAS score after the intervention (CT—p < 0.001, KT—p < 0.001, and sham—p < 0.01). The Kruskal-Wallis ANOVA showed no significant differences in almost all measurements between groups. The application of all three types of tapes does not influence the resting bioelectrical activity of UT muscle and may not lead to a reduction in muscle tone in the case of MTrPs. PMID:26491458
Wrestlers' minimal weight: anthropometry, bioimpedance, and hydrostatic weighing compared.
Oppliger, R A; Nielsen, D H; Vance, C G
1991-02-01
The need for accurate assessment of minimal wrestling weight among interscholastic wrestlers has been well documented. Previous research has demonstrated the validity of anthropometric methods for this purpose, but little research has examined the validity of bioelectrical impedance (BIA) measurements. Comparisons between BIA systems has received limited attention. With these two objectives, we compared the prediction of minimal weight (MW) among 57 interscholastic wrestlers using three anthropometric methods (skinfolds (SF) and two skeletal dimensions equations) and three BIA systems (Berkeley Medical Research (BMR), RJL, and Valhalla (VAL]. All methods showed high correlations (r values greater than 0.92) with hydrostatic weighting (HW) and between methods (r values greater than 0.90). The standard errors of estimate (SEE) were relatively small for all methods, especially for SF and the three BIA systems (SEE less than 0.70 kg). The total errors of prediction (E) for RJL and VAL (E = 4.4 and 3.9 kg) were significantly larger than observed nonsignificant BMR and SF values (E = 2.3 and 1.8 kg, respectively). Significant mean differences were observed between HW, RJL, VAL, and the two skeletal dimensions equations, but nonsignificant differences were observed between HW, BMR, and SF. BMR differed significantly from the RJL and VAL systems. The results suggest that RJL and VAL have potential application for this subpopulation. Prediction equation refinement with the addition of selected anthropometric measurement or moderating variables may enhance their utility. However, within the scope of our study, SF and BMR BIA appear to be the most valid methods for determining MW in interscholastic wrestlers.
Lamarca, F; Carrero, J J; Rodrigues, J C D; Bigogno, F G; Fetter, R L; Avesani, C M
2014-07-01
The prevalence of sarcopenia on elderly maintenance hemodialysis (MHD) has been scarcely investigated. To investigate the prevalence of decreased muscle mass and strength alone or combined (true sarcopenia) in elderly patients on MHD according to different methods and cutoff limits. Additionally, we evaluated the agreement between dual energy x-ray absorptiometry (DXA) and surrogate methods for the assessment of muscle mass. Observational and cross-sectional study. Non-institutionalized 102 elderly (age > 60 years) patients on MHD. Sarcopenia was considered when the patient fit one criteria for low muscle mass assessed by DXA, bioelectrical impedance (BIA), sum of skinfold thicknesses (SKF), calf circumference and mid-arm muscle circumference (MAMC) and one for low muscle strength evaluated by handgrip dynamometer. Decreased muscle strength was found in 85% of the patients. The prevalence of decreased muscle mass varied from 4 to 73.5% and of sarcopenia (decreased muscle mass and strength combined) from 4 to 63%, depending on the method and cutoff limit applied. A small percentage of patients (2 to 15%) were classified as sarcopenic by more than one diagnostic criteria. The agreement between DXA and the surrogate methods to assess muscle mass showed better kappa coefficients with BIA (r=0.36; P<0.01) and SKF (r=0.40; P<0.01). A wide prevalence of sarcopenia is observed depending on the method and cutoff limit applied. This may limit extrapolate on to clinical practice. BIA and SKF were the surrogate methods to assess muscle mass with the best concordance with DXA in elderly MHD patients.
Adams, Dany S.; Levin, Michael
2013-01-01
Alongside the well-known chemical modes of cell-cell communication, we find an important and powerful system of bioelectrical signaling: changes in the resting voltage potential (Vmem) of the plasma membrane driven by ion channels, pumps and gap junctions. Slow Vmem changes in all cells serve as a highly conserved, information-bearing pathway that regulates cell proliferation, migration and differentiation. In embryonic and regenerative pattern formation and in the disorganization of neoplasia, bioelectrical cues serve as mediators of large-scale anatomical polarity, organ identity and positional information. Recent developments have resulted in tools that enable a high-resolution analysis of these biophysical signals and their linkage with upstream and downstream canonical genetic pathways. Here, we provide an overview for the study of bioelectric signaling, focusing on state-of-the-art approaches that use molecular physiology and developmental genetics to probe the roles of bioelectric events functionally. We highlight the logic, strategies and well-developed technologies that any group of researchers can employ to identify and dissect ionic signaling components in their own work and thus to help crack the bioelectric code. The dissection of bioelectric events as instructive signals enabling the orchestration of cell behaviors into large-scale coherent patterning programs will enrich on-going work in diverse areas of biology, as biophysical factors become incorporated into our systems-level understanding of cell interactions. PMID:22350846
Luk, Jason M; Pourbafrani, Mohammad; Saville, Bradley A; MacLean, Heather L
2013-09-17
Our study evaluates life cycle energy use and GHG emissions of lignocellulosic ethanol and bioelectricity use in U.S. light-duty vehicles. The well-to-pump, pump-to-wheel, and vehicle cycle stages are modeled. All ethanol (E85) and bioelectricity pathways have similar life cycle fossil energy use (~ 100 MJ/100 vehicle kilometers traveled (VKT)) and net GHG emissions (~5 kg CO2eq./100 VKT), considerably lower (65-85%) than those of reference gasoline and U.S. grid-electricity pathways. E85 use in a hybrid vehicle and bioelectricity use in a fully electric vehicle also have similar life cycle biomass and total energy use (~ 350 and ~450 MJ/100 VKT, respectively); differences in well-to-pump and pump-to-wheel efficiencies can largely offset each other. Our energy use and net GHG emissions results contrast with findings in literature, which report better performance on these metrics for bioelectricity compared to ethanol. The primary source of differences in the studies is related to our development of pathways with comparable vehicle characteristics. Ethanol or vehicle electrification can reduce petroleum use, while bioelectricity may displace nonpetroleum energy sources. Regional characteristics may create conditions under which either ethanol or bioelectricity may be the superior option; however, neither has a clear advantage in terms of GHG emissions or energy use.
Pirlich, M; Schütz, T; Ockenga, J; Biering, H; Gerl, H; Schmidt, B; Ertl, S; Plauth, M; Lochs, H
2003-04-01
Estimation of body cell mass (BCM) has been regarded valuable for the assessment of malnutrition. To investigate the value of segmental bioelectrical impedance analysis (BIA) for BCM estimation in malnourished subjects and acromegaly. Nineteen controls and 63 patients with either reduced (liver cirrhosis without and with ascites, Cushing's disease) or increased BCM (acromegaly) were included. Whole-body and segmental BIA (separately measuring arm, trunk, leg) at 50 kHz was compared with BCM measured by total-body potassium. Multiple regression analysis was used to develop specific equations for BCM in each subgroup. Compared to whole-body BIA equations, the inclusion of arm resistance improved the specific equation in cirrhotic patients without ascites and in Cushing's disease resulting in excellent prediction of BCM (R(2) = 0.93 and 0.92, respectively; both P<0.001). In acromegaly, inclusion of resistance and reactance of the trunk best described BCM (R(2) = 0.94, P<0.001). In controls and in cirrhotic patients with ascites, segmental impedance parameters did not improve BCM prediction (best values obtained by whole-body measurements: R(2)=0.88 and 0.60; P<0.001 and <0.003, respectively). Segmental BIA improves the assessment of BCM in malnourished patients and acromegaly, but not in patients with severe fluid overload. Copyright 2003 Elsevier Science Ltd.
Pai, Vaibhav P; Lemire, Joan M; Chen, Ying; Lin, Gufa; Levin, Michael
2015-01-01
Bioelectric signals, particularly transmembrane voltage potentials (Vmem), play an important role in large-scale patterning during embryonic development. Endogenous bioelectric gradients across tissues function as instructive factors during eye, brain, and other morphogenetic processes. An important and still poorly-understood aspect is the control of cell behaviors by the voltage states of distant cell groups. Here, experimental alteration of endogenous Vmem was induced in Xenopus laevis embryos by misexpression of well-characterized ion channel mRNAs, a strategy often used to identify functional roles of Vmem gradients during embryonic development and regeneration. Immunofluorescence analysis (for activated caspase 3 and phosphor-histone H3P) on embryonic sections was used to characterize apoptosis and proliferation. Disrupting local bioelectric signals (within the developing neural tube region) increased caspase 3 and decreased H3P in the brain, resulting in brain mispatterning. Disrupting remote (ventral, non-neural region) bioelectric signals decreased caspase 3 and highly increased H3P within the brain, with normal brain patterning. Disrupting both the local and distant bioelectric signals produced antagonistic effects on caspase 3 and H3P. Thus, two components of bioelectric signals regulate apoptosis-proliferation balance within the developing brain and spinal cord: local (developing neural tube region) and distant (ventral non-neural region). Together, the local and long-range bioelectric signals create a binary control system capable of fine-tuning apoptosis and proliferation with the brain and spinal cord to achieve correct pattern and size control. Our data suggest a roadmap for utilizing bioelectric state as a diagnostic modality and convenient intervention parameter for birth defects and degenerative disease states of the CNS.
An optical microfluidic platform for spatiotemporal biofilm treatment monitoring
NASA Astrophysics Data System (ADS)
Kim, Young Wook; Mosteller, Matthew P.; Subramanian, Sowmya; Meyer, Mariana T.; Bentley, William E.; Ghodssi, Reza
2016-01-01
Bacterial biofilms constitute in excess of 65% of clinical microbial infections, with the antibiotic treatment of biofilm infections posing a unique challenge due to their high antibiotic tolerance. Recent studies performed in our group have demonstrated that a bioelectric effect featuring low-intensity electric signals combined with antibiotics can significantly improve the efficacy of biofilm treatment. In this work, we demonstrate the bioelectric effect using sub-micron thick planar electrodes in a microfluidic device. This is critical in efforts to develop microsystems for clinical biofilm infection management, including both in vivo and in vitro applications. Adaptation of the method to the microscale, for example, can enable the development of localized biofilm infection treatment using microfabricated medical devices, while augmenting existing capabilities to perform biofilm management beyond the clinical realm. Furthermore, due to scale-down of the system, the voltage requirement for inducing the electric field is reduced further below the media electrolysis threshold. Enhanced biofilm treatment using the bioelectric effect in the developed microfluidic device elicited a 56% greater reduction in viable cell density and 26% further decrease in biomass growth compared to traditional antibiotic therapy. This biofilm treatment efficacy, demonstrated in a micro-scale device and utilizing biocompatible voltage ranges, encourages the use of this method for future clinical biofilm treatment applications.
Moon, Jordan R; Tobkin, Sarah E; Smith, Abbie E; Roberts, Michael D; Ryan, Eric D; Dalbo, Vincent J; Lockwood, Chris M; Walter, Ashley A; Cramer, Joel T; Beck, Travis W; Stout, Jeffrey R
2008-01-01
Background Methods used to estimate percent body fat can be classified as a laboratory or field technique. However, the validity of these methods compared to multiple-compartment models has not been fully established. The purpose of this study was to determine the validity of field and laboratory methods for estimating percent fat (%fat) in healthy college-age men compared to the Siri three-compartment model (3C). Methods Thirty-one Caucasian men (22.5 ± 2.7 yrs; 175.6 ± 6.3 cm; 76.4 ± 10.3 kg) had their %fat estimated by bioelectrical impedance analysis (BIA) using the BodyGram™ computer program (BIA-AK) and population-specific equation (BIA-Lohman), near-infrared interactance (NIR) (Futrex® 6100/XL), four circumference-based military equations [Marine Corps (MC), Navy and Air Force (NAF), Army (A), and Friedl], air-displacement plethysmography (BP), and hydrostatic weighing (HW). Results All circumference-based military equations (MC = 4.7% fat, NAF = 5.2% fat, A = 4.7% fat, Friedl = 4.7% fat) along with NIR (NIR = 5.1% fat) produced an unacceptable total error (TE). Both laboratory methods produced acceptable TE values (HW = 2.5% fat; BP = 2.7% fat). The BIA-AK, and BIA-Lohman field methods produced acceptable TE values (2.1% fat). A significant difference was observed for the MC and NAF equations compared to both the 3C model and HW (p < 0.006). Conclusion Results indicate that the BP and HW are valid laboratory methods when compared to the 3C model to estimate %fat in college-age Caucasian men. When the use of a laboratory method is not feasible, BIA-AK, and BIA-Lohman are acceptable field methods to estimate %fat in this population. PMID:18426582
Hedderich, Dennis M; Hasenberg, Till; Haneder, Stefan; Schoenberg, Stefan O; Kücükoglu, Özlem; Canbay, Ali; Otto, Mirko
2017-07-01
Non-alcoholic fatty liver disease (NAFLD) is considered the most common liver disease worldwide and is highly associated with obesity. The prevalences of both conditions have markedly increased in the Western civilization. Bariatric surgery is the most effective treatment for morbid obesity and its comorbidities such as NAFLD. Measure postoperative liver fat fraction (LFF) in bariatric patients by using in-opposed-phase MRI, a widely available clinical tool validated for the quantification of liver fat METHODS: Retrospective analyses of participants, who underwent laparoscopic Roux-Y-gastric-bypass (17) or laparoscopic sleeve gastrectomy (2) were performed using magnetic resonance imaging (MRI), bioelectrical impedance analysis (BIA), and anthropometric measurements 1 day before surgery, as well as 6, 12, and 24 weeks after surgery, LFF was calculated from fat-only and water-only MR images. Six months after surgery, a significant decrease of LFF and liver volume has been observed along with weight loss, decreased waist circumference, and parameters obtained by body fat measured by BIA. LFF significantly correlated with liver volume in the postoperative course. MRI including in-opposed-phase imaging of the liver can detect the quantitative decrease of fatty infiltration within the liver after bariatric surgery and thus could be a valuable tool to monitor NAFLD/NASH postoperatively.
Achamrah, Najate; Jésus, Pierre; Grigioni, Sébastien; Rimbert, Agnès; Petit, André; Déchelotte, Pierre; Folope, Vanessa; Coëffier, Moïse
2018-01-01
Predictive equations have been specifically developed for obese patients to estimate resting energy expenditure (REE). Body composition (BC) assessment is needed for some of these equations. We assessed the impact of BC methods on the accuracy of specific predictive equations developed in obese patients. REE was measured (mREE) by indirect calorimetry and BC assessed by bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA). mREE, percentages of prediction accuracy (±10% of mREE) were compared. Predictive equations were studied in 2588 obese patients. Mean mREE was 1788 ± 6.3 kcal/24 h. Only the Müller (BIA) and Harris & Benedict (HB) equations provided REE with no difference from mREE. The Huang, Müller, Horie-Waitzberg, and HB formulas provided a higher accurate prediction (>60% of cases). The use of BIA provided better predictions of REE than DXA for the Huang and Müller equations. Inversely, the Horie-Waitzberg and Lazzer formulas provided a higher accuracy using DXA. Accuracy decreased when applied to patients with BMI ≥ 40, except for the Horie-Waitzberg and Lazzer (DXA) formulas. Müller equations based on BIA provided a marked improvement of REE prediction accuracy than equations not based on BC. The interest of BC to improve REE predictive equations accuracy in obese patients should be confirmed. PMID:29320432
Validation of a three-dimensional body scanner for body composition measures.
Harbin, Michelle M; Kasak, Alexander; Ostrem, Joseph D; Dengel, Donald R
2017-12-29
The accuracy of an infrared three-dimensional (3D) body scanner in determining body composition was compared against hydrostatic weighing (HW), bioelectrical impedance analysis (BIA), and anthropometry. A total of 265 adults (119 males; age = 22.1 ± 2.5 years; body mass index = 24.5 ± 3.9 kg/m 2 ) had their body fat percent (BF%) estimated from 3D scanning, HW, BIA, skinfolds, and girths. A repeated measures analysis of variance (ANOVA) indicated significant differences among methods (p < 0.001). Multivariate ANOVA indicated a significant main effect of sex and method (p < 0.001), with a non-significant interaction (p = 0.101). Bonferroni post-hoc comparisons identified that BF% from 3D scanning (18.1 ± 7.8%) was significantly less than HW (22.8 ± 8.5%, p < 0.001), BIA (20.1 ± 9.1%, p < 0.001), skinfolds (19.7 ± 9.7%, p < 0.001), and girths (21.2 ± 10.4%, p < 0.001). The 3D scanner decreased in precision with increasing adiposity, potentially resulting from inconsistences in the 3D scanner's analysis algorithm. A correction factor within the algorithm is required before infrared 3D scanning can be considered valid in measuring BF%.
Microelectrode array fabrication for electrochemical detection with carbon nanotubes
NASA Astrophysics Data System (ADS)
Clark, James
Understanding how the brain works remains one of the key challenges for scientists. To further this understanding a wide variety of technologies and research methods have been developed. One such technology is conductive electrodes, used to measure the electrical signals elicited from neuronal cells and tissues. These electrodes can be fabricated as a singular electrode or as a multi-electrode array (MEA). This permits bio-electrical measurements from one particular area or simultaneous measurements from multiple areas, respectively. Studying electrical and chemical signals of individual cells in situ requires the use of electrodes with ≤20 µm diameter. However, electrodes of this size generally produce high impedance, perturbing recording of the small signals generated from individual cells. Nanomaterials, such as carbon nanotubes (CNTs), can be deposited to increase the real surface area of these electrodes, producing higher sensitivity measurements. This thesis investigates the potential for using photo-thermal chemical vapour deposition grown CNTs as the electrode material for a de novo fabricated MEA. This device aimed to measure electrochemical signals in the form of dopamine, an important mammalian neurotransmitter, as well as conventional bio-electrical signals that the device is designed for. Realising this aim began with improving CNT aqueous wetting behaviour via oxygen plasma functionalisation. This procedure demonstrated grafting of oxygen functional groups to the CNT structure, and dramatic improvements in aqueous wetting behaviour, with CNTs attached to the device. Subsequently, oxygen plasma functionalised CNT-based MEAs were fabricated and tested, allowing comparisons with a non-functionalised CNT MEA and a state-of-the-art commercial MEA. The functionalised CNT MEA demonstrated an order of magnitude improvement compared to commercial MEAs (2.75 kΩ vs. 25.6 kΩ), at the biologically relevant frequency of 1 kHz. This was followed by measurement of one of the best sensitivity density values, compared to the available literature, for the electrochemical detection of dopamine (9.48 µA µM-1 mm-2). The functionalised CNT MEA then illustrated some selectivity compared to common interferents, i.e. ascorbic acid, of a higher concentration. Nonetheless, imaging of the MEA revealed CNTs were being removed from the electrode areas due to extensive use. Therefore, the final results chapter aimed to develop a novel fabrication route for CNT-based MEAs that produced improved CNT retention on the electrodes. This next-generation functionalised CNT-based MEA displayed improved CNT retention, whilst also producing competitive electrochemical impedance values at 1 kHz (17.8 kΩ) and excellent electrochemical selectivity for dopamine vs. ascorbic acid. Overall, this thesis demonstrates the potential for using MEAs as electrochemical detectors of biological molecules, specifically when using functionalised CNTs as the electrode material.
Moon, Jordan R; Tobkin, Sarah E; Smith, Abbie E; Roberts, Michael D; Ryan, Eric D; Dalbo, Vincent J; Lockwood, Chris M; Walter, Ashley A; Cramer, Joel T; Beck, Travis W; Stout, Jeffrey R
2008-04-21
Methods used to estimate percent body fat can be classified as a laboratory or field technique. However, the validity of these methods compared to multiple-compartment models has not been fully established. The purpose of this study was to determine the validity of field and laboratory methods for estimating percent fat (%fat) in healthy college-age men compared to the Siri three-compartment model (3C). Thirty-one Caucasian men (22.5 +/- 2.7 yrs; 175.6 +/- 6.3 cm; 76.4 +/- 10.3 kg) had their %fat estimated by bioelectrical impedance analysis (BIA) using the BodyGram computer program (BIA-AK) and population-specific equation (BIA-Lohman), near-infrared interactance (NIR) (Futrex(R) 6100/XL), four circumference-based military equations [Marine Corps (MC), Navy and Air Force (NAF), Army (A), and Friedl], air-displacement plethysmography (BP), and hydrostatic weighing (HW). All circumference-based military equations (MC = 4.7% fat, NAF = 5.2% fat, A = 4.7% fat, Friedl = 4.7% fat) along with NIR (NIR = 5.1% fat) produced an unacceptable total error (TE). Both laboratory methods produced acceptable TE values (HW = 2.5% fat; BP = 2.7% fat). The BIA-AK, and BIA-Lohman field methods produced acceptable TE values (2.1% fat). A significant difference was observed for the MC and NAF equations compared to both the 3C model and HW (p < 0.006). Results indicate that the BP and HW are valid laboratory methods when compared to the 3C model to estimate %fat in college-age Caucasian men. When the use of a laboratory method is not feasible, BIA-AK, and BIA-Lohman are acceptable field methods to estimate %fat in this population.
Ignaciuk, Adriana M; Sanders, Johan
2007-12-01
Due to more stringent energy and climate policies, it is expected that many traditional chemicals will be replaced by their biomass-based substitutes, bio-chemicals. These innovations, however, can influence land allocation since the demand for land dedicated to specific crops might increase. Moreover, it can have an influence on traditional agricultural production. In this paper, we use an applied general equilibrium framework, in which we include two different bio-refinery processes and incorporate so-called cascading mechanisms. The bio-refinery processes use grass, as one of the major inputs, to produce bio-nylon and propane-diol (1,3PDO) to substitute currently produced fossil fuel-based nylon and ethane-diol. We examine the impact of specific climate policies on the bioelectricity share in total electricity production, land allocation, and production quantities and prices of selected commodities. The novel technologies become competitive, with an increased stringency of climate policies. This switch, however, does not induce a higher share of bioelectricity. The cascade does stimulate the production of bioelectricity, but it induces more of a shift in inputs in the bioelectricity sector (from biomass to the cascaded bio-nylon and 1, 3PDO) than an increase in production level of bioelectricity. We conclude that dedicated biomass crops will remain the main option for bioelectricity production: the contribution of the biomass systems remains limited. Moreover, the bioelectricity sector looses a competition for land for biomass production with bio-refineries.
Accuracy of specific BIVA for the assessment of body composition in the United States population.
Buffa, Roberto; Saragat, Bruno; Cabras, Stefano; Rinaldi, Andrea C; Marini, Elisabetta
2013-01-01
Bioelectrical impedance vector analysis (BIVA) is a technique for the assessment of hydration and nutritional status, used in the clinical practice. Specific BIVA is an analytical variant, recently proposed for the Italian elderly population, that adjusts bioelectrical values for body geometry. Evaluating the accuracy of specific BIVA in the adult U.S. population, compared to the 'classic' BIVA procedure, using DXA as the reference technique, in order to obtain an interpretative model of body composition. A cross-sectional sample of 1590 adult individuals (836 men and 754 women, 21-49 years old) derived from the NHANES 2003-2004 was considered. Classic and specific BIVA were applied. The sensitivity and specificity in recognizing individuals below the 5(th) and above the 95(th) percentiles of percent fat (FMDXA%) and extracellular/intracellular water (ECW/ICW) ratio were evaluated by receiver operating characteristic (ROC) curves. Classic and specific BIVA results were compared by a probit multiple-regression. Specific BIVA was significantly more accurate than classic BIVA in evaluating FMDXA% (ROC areas: 0.84-0.92 and 0.49-0.61 respectively; p = 0.002). The evaluation of ECW/ICW was accurate (ROC areas between 0.83 and 0.96) and similarly performed by the two procedures (p = 0.829). The accuracy of specific BIVA was similar in the two sexes (p = 0.144) and in FMDXA% and ECW/ICW (p = 0.869). Specific BIVA showed to be an accurate technique. The tolerance ellipses of specific BIVA can be used for evaluating FM% and ECW/ICW in the U.S. adult population.
Comparison in maternal body composition between Caucasian Irish and Indian women.
Farah, N; Murphy, M; Ramphul, M; O'Connor, N; Kennelly, M M; Turner, M J
2011-08-01
The use of body mass index (BMI) for the diagnosis of obesity has limitations, especially when comparing ethnic groups with different body proportions. The aim of this prospective study was to compare maternal body composition in early pregnancy between Caucasian Irish and Indian women. A total of 81 Indian women and 81 Irish Caucasian women were matched for age, parity and BMI. Maternal weight and height were measured, and body composition analysed using bioelectrical impedance. The Irish women were taller and weighed more than the Indian women (p<0.001). At any given BMI, the Indian women had a higher total body fat percentage, visceral fat level and high fat percentage than the Irish women (p=0.024, 0.001 and 0.001, respectively). Our findings suggest that lower BMI cut-offs should be used for screening for gestational diabetes mellitus in Indian women attending our antenatal services.
Chan, U Fai; Chan, Wai Wong; Pun, Sio Hang; Vai, Mang I; Mak, Peng Un
2007-01-01
Traditional/Current electronic circuits for Telemedicine have significant performance on certain bioelectric signal detection. However, it is rarely seen that can handle multiple signals without changing of hardware. This paper introduces a general front-end amplifier for various bioelectric signals based on Field Programmable Analogy Array (FPAA) Technology. Employing FPAA technology, the implemented amplifier can be adapted for various bioelectric signals without alternating the circuitry while its compact size (core parts < 2 cm2) provides an alternative solution for miniaturized Telemedicine system and Wearable Devices. The proposed design implementation has demonstrated, through successfully ECG and EMG signal extractions, a quick way to miniaturize analog biomedical circuit in a convenient and cost effective way.
Low noise multi-channel biopotential wireless data acquisition system for dry electrodes
NASA Astrophysics Data System (ADS)
Pandian, P. S.; Whitchurch, Ashwin K.; Abraham, Jose K.; Bhusan Baskey, Himanshu; Radhakrishnan, J. K.; Varadan, Vijay K.; Padaki, V. C.; Bhasker Rao, K. U.; Harbaugh, R. E.
2008-03-01
The bioelectrical potentials generated within the human body are the result of electrochemical activity in the excitable cells of the nervous, muscular or glandular tissues. The ionic potentials are measured using biopotential electrodes which convert ionic potentials to electronic potentials. The commonly monitored biopotential signals are Electrocardiogram (ECG), Electroencephalogram (EEG) and Electromyogram (EMG). The electrodes used to monitor biopotential signals are Ag-AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gels used in biopotential recordings dry out when used for longer durations and add noise to the signals and also prolonged use of gels cause irritations and rashes to skin. Also noises such as motion artifact and baseline wander are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry electrodes are used, where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The major drawback associated with the dry electrodes is the high skin-electrode impedance in the low frequency range between 0.1-120 Hz, which makes it difficult to acquire clean and noise free biopotential signals. The paper presents the design and development of biopotential data acquisition and processing system to acquire biopotential signals from dry electrodes. The electrode-skin-electrode- impedance (ESEI) measurements was carried out for the dry electrodes by impedance spectroscopy. The biopotential signals are processed using an instrumentation amplifier with high CMRR and high input impedance achieved by boot strapping the input terminals. The signals are band limited by means of a second order Butterworth band pass filters to eliminate noise. The processed biopotential signals are digitized and transmitted wirelessly to a remote monitoring station.
NASA Astrophysics Data System (ADS)
Yanagibashi, Hideyuki; Hirama, Junji; Matsuda, Masato; Miyamoto, Toshio
The purpose of this study was to investigate the optimum farming conditions for mushrooms from the view point of engineering field. As the bio-electric potential of mushrooms is considered to be closely related to the activation of mushroom cells, this relationship has been used to analyze the dependence of the morphogenetic characteristics of Grifola frondosa on farming temperatures (from 16 to 22 degree C). The experimental results indicated that a maximum response was exhibited, with correspondingly favorable morphogenesis obtained at 18 degree C. Based on the experimental results, including those in a previous study, it was assumed that the larger the bio-electric potential becomes, the higher the growth yield reaches. In order to support this assumption, growth promotion was conducted by intentionally activating the bio-electric potential within the mushrooms by stimulating them with short bursts of illumination. The resulting observation of growth promotion permitted the conclusion that the bio-electric potential can, indeed, be regarded as an index of growth.
FAT-FREE MASS, METABOLICALLY HEALTHY OBESITY, AND TYPE 2 DIABETES IN SEVERELY OBESE ASIAN ADULTS.
Pramyothin, Pornpoj; Limpattanachart, Vichol; Dawilai, Suwitcha; Sarasak, Rungnapha; Sukaruttanawong, Chariya; Chaiyasoot, Kusuma; Keawtanom, Songsri; Yamwong, Preyanuj
2017-08-01
To determine whether fat free mass (FFM) is independently associated with the metabolically healthy obesity (MHO) phenotype, the metabolic syndrome (MS), and type 2 diabetes (T2D) in obese Asian adults. Obese patients (body mass index [BMI] ≥25 kg/m 2 ) seeking weight management at an academic medical center from 2007 to 2016 were included. FFM was measured by bioelectrical impedance. Of the 552 patients (67.0% female, median age 40.5 years, median BMI 38.3 kg/m 2 ), MHO was present in 19%, MS in 55.4%, and T2D in 32.6%. In multivariate models, higher fat-free mass index (FFMI) was independently associated with the metabolically abnormal obesity (MAO) phenotype, (odds ratio [OR] 1.22, 95% confidence interval [CI] 1.09-1.37), and increased risk of MS (OR 1.12, 95% CI 1.03-1.22) in women but not in men. Older age was independently associated with the MAO phenotype (OR 1.06, 95% CI 1.04-1.09 in women; OR 1.06, 95% CI 1.02-1.09 in men), MS (OR 1.05, 95% CI 1.03-1.06 in women; OR 1.05, 95% CI 1.02-1.07 in men), and T2D (OR 1.07, 95% CI 1.05-1.09 in women; OR 1.06, 95% CI 1.04-1.09 in men). Waist-hip ratio was independently associated with the MAO phenotype in men (OR 1.08, 95% CI 1.01-1.15), while waist circumference was associated with T2D in women (OR 1.03, 95% CI 1.01-1.05). Older age, central fat distribution, and-in contrast to previous findings-an increase in FFMI among women were independent predictors of adverse metabolic health in this cohort of middle-aged obese Asian adults. Further studies are required to elucidate underlying mechanisms and therapeutic implications of these findings. BIA = bioelectrical impedance analysis BMI = body mass index CI = confidence interval DXA = dual-energy X-ray absorptiometry FFM = fat-free mass FFMI = fat-free mass index FM = fat mass HbA1c = glycated hemoglobin A1c MAO = metabolically abnormal obesity MHO = metabolically healthy obesity MS = metabolic syndrome OR = odds ratio T2D = type 2 diabetes WC = waist circumference WHR = waist-hip-ratio.
Dip, Renata Maciulis; Cabrera, Marcos AS; Prato, Sabrina Ferrari
2017-01-01
Background Loss of muscle strength exerts a considerable impact on the quality of life and mortality of older adults. The present household survey study measured body composition and muscle strength with the aim of analyzing the roles of low lean mass, low muscle strength and obesity in stair negotiation ability and the effect of comorbidities on the relationship between body composition and functional capacity. Methods Body composition was assessed using bioelectrical impedance analysis and muscle strength was assessed with a hand grip dynamometer. The study population comprised individuals >55 years of age from a medium-sized Brazilian municipality. The sample included 451 participants. Results A total of 368 subjects were interviewed; their ages varied from 56 to 91 years. Among males, low muscle strength was associated with stair negotiation difficulty independent of muscle mass, age and obesity but muscle mass was not. However, when we analyzed comorbidities and body composition jointly, chronic lower limb pain and obesity were independently associated with stair negotiation difficulty but body composition and age were not. Among women, after comorbidities were included into the model, low muscle strength and obesity remained associated with stair negotiation difficulty as chronic lower limb pain and depression. The relationship between muscle function and comorbidities is discussed in this article. PMID:28860730
Costa, Caroline Santos; Del-Ponte, Bianca; Assunção, Maria Cecília Formoso; Santos, Iná Silva
2018-01-01
To review the available literature on the association between consumption of ultra-processed foods and body fat during childhood and adolescence. A systematic review was conducted in the PubMed, Web of Science and LILACS databases. Studies that evaluated the association between consumption of ultra-processed food (exposure) and body fat (outcome) during childhood and adolescence were eligible. Healthy children and adolescents. Twenty-six studies that evaluated groups of ultra-processed foods (such as snacks, fast foods, junk foods and convenience foods) or specific ultra-processed foods (soft drinks/sweetened beverages, sweets, chocolate and ready-to-eat cereals) were selected. Most of the studies (n 15) had a cohort design. Consumption was generally evaluated by means of FFQ or food records; and body composition, by means of double indirect methods (bioelectrical impedance analysis and skinfolds). Most of the studies that evaluated consumption of groups of ultra-processed foods and soft drinks/sweetened beverages found positive associations with body fat. Our review showed that most studies have found positive associations between consumption of ultra-processed food and body fat during childhood and adolescence. There is a need to use a standardized classification that considers the level of food processing to promote comparability between studies.
Vitturi, Nicola; Soattin, Marta; De Stefano, Fabio; Vianello, Daniela; Zambon, Alberto; Plebani, Mario; Busetto, Luca
2015-06-01
The aim of our study was the evaluation of anthropometric measurements [waist circumference and sagittal abdominal diameter (SAD)] and abdominal bioelectrical impedance analysis (BIA) (ViScan, TANITA) in comparison to several abdominal ultrasonographic (US) measurements to estimate visceral fat deposition and liver steatosis in a population of 105 subjects. All 105 patients underwent a complete anthropometric evaluation, blood sample for the determination of total cholesterol, HDL cholesterol, triglycerides, glucose, insulin, high-sensitivity C-reactive protein, BIA and US measurements (peritoneal, pre-peritoneal, peri-renal, para-renal and peri-hepatic fat thickness). All the ultrasonographic markers considered in our study are related to the presence of non-alcoholic fatty liver disease (NAFLD), and so is true for SAD. Comparing ROC curves, peritoneal fat tissue thickness, SAD and ViScan visceral index are significantly better than waist circumference in predicting the presence of NAFLD (AUC 0.79 ± 0.04; 0.81 ± 0.05; 0.82 ± 0.04 vs 0.76 ± 0.05, respectively). According to our data, various methods may be useful in evaluating NAFLD, but only ViScan visceral index, US peritoneal fat thickness and SAD are better than waist circumference. Among them, SAD is the most promising, due to its small cost and time consumption.
BOOK REVIEW Handbook of Physics in Medicine and Biology Handbook of Physics in Medicine and Biology
NASA Astrophysics Data System (ADS)
Tabakov, Slavik
2010-11-01
This is a multi-author handbook (66 authors) aiming to describe various applications of physics to medicine and biology, from anatomy and physiology to medical equipment. This unusual reference book has 44 chapters organized in seven sections: 1. Anatomical physics; 2. Physics of perception; 3. Biomechanics; 4. Electrical physics; 5. Diagnostic physics; 6. Physics of accessory medicine; 7. Physics of bioengineering. Each chapter has separate page numbering, which is inconvenient but understandable with the number of authors. Similarly there is some variation in the emphasis of chapters: for some the emphasis is more technical and for others clinical. Each chapter has a separate list of references. The handbook includes hundreds of diagrams, images and tables, making it a useful tool for both medical physicists/engineers and other medical/biology specialists. The first section (about 40 pages) includes five chapters on physics of the cell membrane; protein signaling; cell biology and biophysics of the cell membrane; cellular thermodynamics; action potential transmission and volume conduction. The physics of these is well explained and illustrated with clear diagrams and formulae, so it could be a suitable reference for physicists/engineers. The chapters on cellular thermodynamics and action potential transmission have a very good balance of technical/clinical content. The second section (about 85 pages) includes six chapters on medical decision making; senses; somatic senses: touch and pain; hearing; vision; electroreception. Again these are well illustrated and a suitable reference for physicists/engineers. The chapter on hearing stands out with good balance and treatment of material, but some other chapters contain less physics and are close to typical physiological explanations. One could query the inclusion of the chapter on medical decision making, which also needs more detail. The third section (about 80 pages) includes eight chapters on biomechanics; artificial muscle; cardiovascular system; control of cardiac output and arterial blood pressure regulation; fluid dynamics of the cardiovascular system; fluid dynamics; modeling and simulation of the cardiovascular system to determine work using bond graphs; anatomy and physics of respiration. The diagrams and data in this section could be used as reference material, but some chapters (such as that on the cardiovascular system) again take the form of physiological explanations. The best chapters in this section are on fluid dynamics and modeling. The fourth section (about 30 pages) includes two chapters on electrodes and recording of bioelectrical signals: theory and practice. Both chapters deal with electrodes and are well written and illustrated reference materials. This section could have been larger but the equipment associated with bioelectrical signals (such as ECG and EEG) is described in the next section. The fifth section (about 210 pages) includes 19 chapters on medical sensing and imaging; electrocardiogram: electrical information retrieval and diagnostics from the beating heart; electroencephalography: basic concepts and brain applications; bioelectric impedance analysis; x-ray and computed tomography; confocal microscopy; magnetic resonance imaging; positron emission tomography; in vivo fluorescence imaging and spectroscopy; optical coherence tomography; ultrasonic imaging; near-field imaging; atomic force microscopy; scanning ion conductance microscopy; quantitative thermographic imaging; intracoronary thermography; schlieren imaging: optical techniques to visualize thermal interactions with biological tissues; helium ion microscopy; electron microscopy: SEM/TEM. This is by far the largest section covering various methods and medical equipment and the variation in emphasis/quality is more prominent. The chapters on ECG and EEG are again more physiological with less physics, but the chapter on bioelectric impedance analysis is a good interdisciplinary article. The imaging chapters also vary in style and quality: while those on MRI and ultrasound provide a suitable introduction to the methods, the chapters on x-ray and PET need more detail. However this section includes some methods/equipment rarely featured in medical physics/engineering books (such as OCT or HIM). From this point of view the last eight chapters in the section will be a very useful reference for various specialists. The sixth section (about 30 pages) includes three chapters on lab-on-a-chip; the biophysics of DNA microarrays; nuclear medicine. While the first two could provide an interesting reference, the chapter on nuclear medicine needs much more detail. The last (seventh) section (15 pages) has only one chapter on biophysics of regenerative medicine, which is a good introduction, emphasizing biochemical factors important for improving/replacing tissues or tissue structures. The book ends with an index covering about 1400 terms. The handbook will be useful for the preparation of teaching materials and for undergraduate students, but should be complemented with more detailed/specific reference materials such as the Encyclopedia of Medical Devices and Instrumentation, the Encyclopedia of Medical Physics Emitel, or others. Parts of the handbook would be less suitable for more demanding readers (such as trainee medical physicists or radiologists, for example). In conclusion, the Handbook of Physics in Medicine and Biology includes materials that are rarely combined together, which strengthens its interdisciplinary approach and makes it an additional reference for a departmental library.
Zhao, Dong-Jie; Chen, Yang; Wang, Zi-Yang; Xue, Lin; Mao, Tong-Lin; Liu, Yi-Min; Wang, Zhong-Yi; Huang, Lan
2015-01-01
The limitations of conventional extracellular recording and intracellular recording make high-resolution multisite recording of plant bioelectrical activity in situ challenging. By combining a cooled charge-coupled device camera with a voltage-sensitive dye, we recorded the action potentials in the stem of Helianthus annuus and variation potentials at multiple sites simultaneously with high spatial resolution. The method of signal processing using coherence analysis was used to determine the synchronization of the selected signals. Our results provide direct visualization of the phloem, which is the distribution region of the electrical activities in the stem and leaf of H. annuus, and verify that the phloem is the main action potential transmission route in the stems of higher plants. Finally, the method of optical recording offers a unique opportunity to map the dynamic bioelectrical activity and provides an insight into the mechanisms of long-distance electrical signal transmission in higher plants. PMID:26333536
Krüger, Julia; Bohrmann, Johannes
2015-01-16
Bioelectric phenomena have been found to exert influence on various developmental and regenerative processes. Little is known about their possible functions and the cellular mechanisms by which they might act during Drosophila oogenesis. In developing follicles, characteristic extracellular current patterns and membrane-potential changes in oocyte and nurse cells have been observed that partly depend on the exchange of protons, potassium ions and sodium ions. These bioelectric properties have been supposed to be related to various processes during oogenesis, e. g. pH-regulation, osmoregulation, cell communication, cell migration, cell proliferation, cell death, vitellogenesis and follicle growth. Analysing in detail the spatial distribution and activity of the relevant ion-transport mechanisms is expected to elucidate the roles that bioelectric phenomena play during oogenesis. To obtain an overview of bioelectric patterning along the longitudinal and transversal axes of the developing follicle, the spatial distributions of membrane potentials (Vmem), intracellular pH (pHi) and various membrane-channel proteins were studied systematically using fluorescent indicators, fluorescent inhibitors and antisera. During mid-vitellogenic stages 9 to 10B, characteristic, stage-specific Vmem-patterns in the follicle-cell epithelium as well as anteroposterior pHi-gradients in follicle cells and nurse cells were observed. Corresponding distribution patterns of proton pumps (V-ATPases), voltage-dependent L-type Ca(2+)-channels, amiloride-sensitive Na(+)-channels and Na(+),H(+)-exchangers (NHE) and gap-junction proteins (innexin 3) were detected. In particular, six morphologically distinguishable follicle-cell types are characterized on the bioelectric level by differences concerning Vmem and pHi as well as specific compositions of ion channels and carriers. Striking similarities between Vmem-patterns and activity patterns of voltage-dependent Ca(2+)-channels were found, suggesting a mechanism for transducing bioelectric signals into cellular responses. Moreover, gradients of electrical potential and pH were observed within single cells. Our data suggest that spatial patterning of Vmem, pHi and specific membrane-channel proteins results in bioelectric signals that are supposed to play important roles during oogenesis, e. g. by influencing spatial coordinates, regulating migration processes or modifying the cytoskeletal organization. Characteristic stage-specific changes of bioelectric activity in specialized cell types are correlated with various developmental processes.
Interfacing with the nervous system: a review of current bioelectric technologies.
Sahyouni, Ronald; Mahmoodi, Amin; Chen, Jefferson W; Chang, David T; Moshtaghi, Omid; Djalilian, Hamid R; Lin, Harrison W
2017-10-23
The aim of this study is to discuss the state of the art with regard to established or promising bioelectric therapies meant to alter or control neurologic function. We present recent reports on bioelectric technologies that interface with the nervous system at three potential sites-(1) the end organ, (2) the peripheral nervous system, and (3) the central nervous system-while exploring practical and clinical considerations. A literature search was executed on PubMed, IEEE, and Web of Science databases. A review of the current literature was conducted to examine functional and histomorphological effects of neuroprosthetic interfaces with a focus on end-organ, peripheral, and central nervous system interfaces. Innovations in bioelectric technologies are providing increasing selectivity in stimulating distinct nerve fiber populations in order to activate discrete muscles. Significant advances in electrode array design focus on increasing selectivity, stability, and functionality of implantable neuroprosthetics. The application of neuroprosthetics to paretic nerves or even directly stimulating or recording from the central nervous system holds great potential in advancing the field of nerve and tissue bioelectric engineering and contributing to clinical care. Although current physiotherapeutic and surgical treatments seek to restore function, structure, or comfort, they bear significant limitations in enabling cosmetic or functional recovery. Instead, the introduction of bioelectric technology may play a role in the restoration of function in patients with neurologic deficits.
The bioelectric code: An ancient computational medium for dynamic control of growth and form.
Levin, Michael; Martyniuk, Christopher J
2018-02-01
What determines large-scale anatomy? DNA does not directly specify geometrical arrangements of tissues and organs, and a process of encoding and decoding for morphogenesis is required. Moreover, many species can regenerate and remodel their structure despite drastic injury. The ability to obtain the correct target morphology from a diversity of initial conditions reveals that the morphogenetic code implements a rich system of pattern-homeostatic processes. Here, we describe an important mechanism by which cellular networks implement pattern regulation and plasticity: bioelectricity. All cells, not only nerves and muscles, produce and sense electrical signals; in vivo, these processes form bioelectric circuits that harness individual cell behaviors toward specific anatomical endpoints. We review emerging progress in reading and re-writing anatomical information encoded in bioelectrical states, and discuss the approaches to this problem from the perspectives of information theory, dynamical systems, and computational neuroscience. Cracking the bioelectric code will enable much-improved control over biological patterning, advancing basic evolutionary developmental biology as well as enabling numerous applications in regenerative medicine and synthetic bioengineering. Copyright © 2017 Elsevier B.V. All rights reserved.
Comparison of methods to assess change in children’s body composition123
Elberg, Jane; McDuffie, Jennifer R; Sebring, Nancy G; Salaita, Christine; Keil, Margaret; Robotham, Delphine; Reynolds, James C; Yanovski, Jack A
2008-01-01
Background Little is known about how simpler and more available methods to measure change in body fatness compare with criterion methods such as dual-energy X-ray absorptiometry (DXA) in children. Objective Our objective was to determine the ability of air-displacement plethysmography (ADP) and formulas based on triceps skinfold thickness (TSF) and bioelectrical impedance analysis (BIA) to estimate changes in body fat over time in children. Design Eighty-six nonoverweight and overweight boys (n = 34) and girls (n = 52) with an average age of 11.0 ± 2.4 y underwent ADP, TSF measurement, BIA, and DXA to estimate body fatness at baseline and 1 ± 0.3 y later. Recent equations were used to estimate percentage body fat by TSF measurement (Dezenberg equation) and by BIA (Suprasongsin and Lewy equations). Percentage body fat estimates by ADP, TSF measurement, and BIA were compared with those by DXA. Results All methods were highly correlated with DXA (P < 0.001). No mean bias for estimates of percentage body fat change was found for ADP (Siri equation) compared with DXA for all subjects examined together, and agreement between body fat estimation by ADP and DXA did not vary with race or sex. Magnitude bias was present for ADP relative to DXA (P < 0.01). Estimates of change in percentage body fat were systematically overestimated by BIA equations (1.37 ± 6.98%; P < 0.001). TSF accounted for only 13% of the variance in percentage body fat change. Conclusion Compared with DXA, there appears to be no noninvasive and simple method to measure changes in children’s percentage body fat accurately and precisely, but ADP performed better than did TSF or BIA. ADP could prove useful for measuring changes in adiposity in children. PMID:15213029
Anthropometric profile of combat athletes via multivariate analysis.
Burdukiewicz, Anna; Pietraszewska, Jadwiga; Stachoń, Aleksandra; Andrzejewska, Justyna
2017-11-07
Athletic success is a complex phenotype influenced by multiple factors, from sport-specific skills to anthropometric characteristics. Considering the latter, the literature has repeatedly indicated that athletes possess distinct physical characteristics depending on the practiced discipline. The aim of the present study was to apply univariate and multivariate methods to assess a wide range of morphometric and somatotypic characteristics in male combat athletes. Biometric data were obtained from 206 male university-level practitioners of judo, jiu-jitsu, karate, kickboxing, taekwondo, and wrestling. Measures included height- and length-based variables, breadths, circumferences, and skinfolds. Body proportions and somatotype, using Sheldon's method of somatotopy as modified by Heath and Carter, were then determined. Body fat percentage was assessed by bioelectrical impedance analysis using tetrapolar hand-to-foot electrodes. Data were subjected to a wide array of statistical analysis. The results show between-group differences in the magnitudes of the analyzed characteristics. While mesomorphy was the dominant component of each group somatotype, enhanced ectomorphy was observed in those disciplines that require a high level of agility. Principal component analysis reduced the multivariate dimensionality of the data to three components (characterizing body size, height-based measures, and the anthropometric structure of the upper extremities) that explained the majority of data variance. The development of a sport-specific anthropometric profile via height- and mass-based and morphometric and somatotypic variables can aid in the design of training protocols and the identification of athlete markers as well as serve as a diagnostic criterion in predicting combat athlete performance.
Alkahtani, Shaea A
2017-03-21
The aim of this study was to determine reference values for sarcopenia indices using different methods in healthy Saudi young men. Participants included 232 Saudi men aged between 20 and 35 years. The study measured anthropometric indices, blood pressure, hand grip strength, and lean muscle mass using dual-energy X-ray absorptiometry (DXA), and bioelectrical impedance analysis (BIA) was performed using Inbody 770 and Tanita 980 devices. Using DXA, the mean value of appendicular lean mass divided by the height squared (ALM/ht 2 ) was found to be 8.97 ± 1.23 kg/m 2 ; hand grip strength measured 42.8 ± 7.6 kg. While the differences between DXA and BIA (Tanita) were significant for all parameters, the differences between DXA and Inbody values were significant only for ALM parameters. Inbody sensitivity and specificity values were 73% and 95.9%, respectively. The kappa (P = 0.80) and p values (P < 0.001) showed good agreement between Inbody and DXA, whereas Tanita sensitivity and specificity values were 54.2% and 98.3%, respectively. Bland-Altman plots for differences in lean mass values between Tanita, Inbody, and DXA methods showed very high bias for Tanita and DXA, with significant differences (P < 0.001). The cut-off values for sarcopenia indices for Saudi young men are different from those of other ethnicities. The use of tailored cut-off reference values instead of a general cut-off for BIA devices is recommended.
Cervera, Javier; Manzanares, José A; Mafe, Salvador
2018-04-04
Genetic networks operate in the presence of local heterogeneities in single-cell transcription and translation rates. Bioelectrical networks and spatio-temporal maps of cell electric potentials can influence multicellular ensembles. Could cell-cell bioelectrical interactions mediated by intercellular gap junctions contribute to the stabilization of multicellular states against local genetic heterogeneities? We theoretically analyze this question on the basis of two well-established experimental facts: (i) the membrane potential is a reliable read-out of the single-cell electrical state and (ii) when the cells are coupled together, their individual cell potentials can be influenced by ensemble-averaged electrical potentials. We propose a minimal biophysical model for the coupling between genetic and bioelectrical networks that associates the local changes occurring in the transcription and translation rates of an ion channel protein with abnormally low (depolarized) cell potentials. We then analyze the conditions under which the depolarization of a small region (patch) in a multicellular ensemble can be reverted by its bioelectrical coupling with the (normally polarized) neighboring cells. We show also that the coupling between genetic and bioelectric networks of non-excitable cells, modulated by average electric potentials at the multicellular ensemble level, can produce oscillatory phenomena. The simulations show the importance of single-cell potentials characteristic of polarized and depolarized states, the relative sizes of the abnormally polarized patch and the rest of the normally polarized ensemble, and intercellular coupling.
Bioelectric modulation of wound healing in a 3D in vitro model of tissue-engineered bone.
Sundelacruz, Sarah; Li, Chunmei; Choi, Young Jun; Levin, Michael; Kaplan, David L
2013-09-01
Long-standing interest in bioelectric regulation of bone fracture healing has primarily focused on exogenous stimulation of bone using applied electromagnetic fields. Endogenous electric signals, such as spatial gradients of resting potential among non-excitable cells in vivo, have also been shown to be important in cell proliferation, differentiation, migration, and tissue regeneration, and may therefore have as-yet unexplored therapeutic potential for regulating wound healing in bone tissue. To study this form of bioelectric regulation, there is a need for three-dimensional (3D) in vitro wound tissue models that can overcome limitations of current in vivo models. We present a 3D wound healing model in engineered bone tissue that serves as a pre-clinical experimental platform for studying electrophysiological regulation of wound healing. Using this system, we identified two electrophysiology-modulating compounds, glibenclamide and monensin, that augmented osteoblast mineralization. Of particular interest, these compounds displayed differential effects in the wound area compared to the surrounding tissue. Several hypotheses are proposed to account for these observations, including the existence of heterogeneous subpopulations of osteoblasts that respond differently to bioelectric signals, or the capacity of the wound-specific biochemical and biomechanical environment to alter cell responses to electrophysiological treatments. These data indicate that a comprehensive characterization of the cellular, biochemical, biomechanical, and bioelectrical components of in vitro wound models is needed to develop bioelectric strategies to control cell functions for improved bone regeneration. Copyright © 2013 Elsevier Ltd. All rights reserved.
A Radio Frequency Electric Current Enhances Antibiotic Efficacy against Bacterial Biofilms
Caubet, R.; Pedarros-Caubet, F.; Chu, M.; Freye, E.; de Belém Rodrigues, M.; Moreau, J. M.; Ellison, W. J.
2004-01-01
Bacterial biofilms are notably resistant to antibiotic prophylaxis. The concentration of antibiotic necessary to significantly reduce the number of bacteria in the biofilm matrix can be several hundred times the MIC for the same bacteria in a planktonic phase. It has been observed that the addition of a weak continuous direct electric current to the liquid surrounding the biofilm can dramatically increase the efficacy of the antibiotic. This phenomenon, known as the bioelectric effect, has only been partially elucidated, and it is not certain that the electrical parameters are optimal. We confirm here the bioelectric effect for Escherichia coli biofilms treated with gentamicin and with oxytetracycline, and we report a new bioelectric effect with a radio frequency alternating electric current (10 MHz) instead of the usual direct current. None of the proposed explanations (transport of ions within the biofilm, production of additional biocides by electrolysis, etc.) of the direct current bioelectric effect are applicable to the radio frequency bioelectric effect. We suggest that this new phenomenon may be due to a specific action of the radio frequency electromagnetic field upon the polar parts of the molecules forming the biofilm matrix. PMID:15561841
Ræder, Hanna; Kværner, Ane Sørlie; Henriksen, Christine; Florholmen, Geir; Henriksen, Hege Berg; Bøhn, Siv Kjølsrud; Paur, Ingvild; Smeland, Sigbjørn; Blomhoff, Rune
2018-02-01
Bioelectrical impedance analysis (BIA) is an accessible and cheap method to measure fat-free mass (FFM). However, BIA estimates are subject to uncertainty in patient populations with altered body composition and hydration. The aim of the current study was to validate a whole-body and a segmental BIA device against dual-energy X-ray absorptiometry (DXA) in colorectal cancer (CRC) patients, and to investigate the ability of different empiric equations for BIA to predict DXA FFM (FFM DXA ). Forty-three non-metastatic CRC patients (aged 50-80 years) were enrolled in this study. Whole-body and segmental BIA FFM estimates (FFM whole-bodyBIA , FFM segmentalBIA ) were calculated using 14 empiric equations, including the equations from the manufacturers, before comparison to FFM DXA estimates. Strong linear relationships were observed between FFM BIA and FFM DXA estimates for all equations (R 2 = 0.94-0.98 for both devices). However, there were large discrepancies in FFM estimates depending on the equations used with mean differences in the ranges -6.5-6.8 kg and -11.0-3.4 kg for whole-body and segmental BIA, respectively. For whole-body BIA, 77% of BIA derived FFM estimates were significantly different from FFM DXA , whereas for segmental BIA, 85% were significantly different. For whole-body BIA, the Schols* equation gave the highest agreement with FFM DXA with mean difference ±SD of -0.16 ± 1.94 kg (p = 0.582). The manufacturer's equation gave a small overestimation of FFM with 1.46 ± 2.16 kg (p < 0.001) with a tendency towards proportional bias (r = 0.28, p = 0.066). For segmental BIA, the Heitmann* equation gave the highest agreement with FFM DXA (0.17 ± 1.83 kg (p = 0.546)). Using the manufacturer's equation, no difference in FFM estimates was observed (-0.34 ± 2.06 kg (p = 0.292)), however, a clear proportional bias was detected (r = 0.69, p < 0.001). Both devices demonstrated acceptable ability to detect low FFM compared to DXA using the optimal equation. In a population of non-metastatic CRC patients, mostly consisting of Caucasian adults and with a wide range of body composition measures, both the whole-body BIA and segmental BIA device provide FFM estimates that are comparable to FFM DXA on a group level when the appropriate equations are applied. At the individual level (i.e. in clinical practice) BIA may be a valuable tool to identify patients with low FFM as part of a malnutrition diagnosis. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Bioelectrical Markers of ADHD: Enhancement of Direct EEG Analysis
ERIC Educational Resources Information Center
Martín-Brufau, Ramón; Nombela Gómez, Manuel
2017-01-01
Introduction: So far some methods to help diagnosis of ADHD grounded in EEG decomposition by the FFT method and the discovery of the relationship between different frequency bands, the most clarifying the TBR rate in the prefrontal regions, have been proposed. This procedure requires a complex gadgetry so we evaluate the advantages of a simple…
Richardson, John G [Idaho Falls, ID
2009-11-17
An impedance estimation method includes measuring three or more impedances of an object having a periphery using three or more probes coupled to the periphery. The three or more impedance measurements are made at a first frequency. Three or more additional impedance measurements of the object are made using the three or more probes. The three or more additional impedance measurements are made at a second frequency different from the first frequency. An impedance of the object at a point within the periphery is estimated based on the impedance measurements and the additional impedance measurements.
Mathews, Juanita; Levin, Michael
2018-04-20
Breakthroughs in biomedicine and synthetic bioengineering require predictive, rational control over anatomical structure and function. Recent successes in manipulating cellular and molecular hardware have not been matched by progress in understanding the patterning software implemented during embryogenesis and regeneration. A fundamental capability gap is driving desired changes in growth and form to address birth defects and traumatic injury. Here we review new tools, results, and conceptual advances in an exciting emerging field: endogenous non-neural bioelectric signaling, which enables cellular collectives to make global decisions and implement large-scale pattern homeostasis. Spatially distributed electric circuits regulate gene expression, organ morphogenesis, and body-wide axial patterning. Developmental bioelectricity facilitates the interface to organ-level modular control points that direct patterning in vivo. Cracking the bioelectric code will enable transformative progress in bioengineering and regenerative medicine. Copyright © 2018 Elsevier Ltd. All rights reserved.
Datta Banik, Sudip; Mendez, Nina; Dickinson, Federico
2015-01-01
Early menarche (EM) (i.e., age at menarche [AAM] <12 years of age) is related to short height and higher body fatness. In a mixed-longitudinal study done in Merida, Yucatan, height, body mass index (BMI), and percentage of body fat (BF%) were recorded at a one-year interval among 258 postmenarcheal (EM = 94) girls. Anthropometric measurements were recorded of the age cohorts in 2008-09 when participants were 13-17 years of age (baseline), and in the one-year follow-up study (± 6 days) the girls were 14-18 years of age. The BF% was estimated through bioelectrical impedance analysis. Mean AAM was 10.59 years in EM girls and 12.54 years in not early menarche (NEM) girls. Height growth (cm/year) was greater in NEM girls. Mean values of BMI, BF%, and frequencies of stunting (low height-for-age) and excess weight (overweight + obesity) were higher in EM girls than in their NEM age peers.
Piernas Sánchez, C M; Morales Falo, E M; Zamora Navarro, S; Garaulet Aza, M
2010-01-01
The excess of visceral abdominal adipose tissue is one of the major concerns in obesity and its clinical treatment. To apply the two-dimensional predictive equation proposed by Garaulet et al. to determine the abdominal fat distribution and to compare the results with the body composition obtained by multi-frequency bioelectrical impedance analysis (M-BIA). We studied 230 women, who underwent anthropometry and M-BIA. The predictive equation was applied. Multivariate lineal and partial correlation analyses were performed with control for BMI and % body fat, using SPSS 15.0 with statistical significance P < 0.05. Overall, women were considered as having subcutaneous distribution of abdominal fat. Truncal fat, regional fat and muscular mass were negatively associated with VA/SA(predicted), while the visceral index obtained by M-BIA was positively correlated with VA/SA(predicted). The predictive equation may be useful in the clinical practice to obtain an accurate, costless and safe classification of abdominal obesity.
Effect of choice of outcome measure on studies of the etiology of obesity in children.
Basterfield, Laura; Pearce, Mark S; Adamson, Ashley J; Reilly, Jessica K; Parkinson, Kathryn N; Reilly, John J
2012-12-01
Epidemiologic studies of the etiology of childhood obesity often use proxies for adiposity as outcomes. This study aimed to compare the ability of a range of proxy measures to detect associations with sedentary behavior. Longitudinal study of children in the Gateshead Millennium Study who were 7 years at baseline and 9 years at follow-up. Associations between 2-year changes in objectively measured sedentary behavior and changes in proxies for adiposity (waist circumference, waist Z score, body mass index, body mass index Z score) and measurement of body composition (fat mass index from bioelectric impedance) were examined. Associations were tested with linear regression. Associations between 2-year increases in sedentary behavior and increases in adiposity were detectable by using the fat mass index as the outcome, but not the simple proxy measures of adiposity, as outcomes. Proxy measures are inferior to measures of body composition as outcomes in epidemiologic studies. Copyright © 2012 Elsevier Inc. All rights reserved.
Fad diets and obesity--Part I: Measuring weight in a clinical setting.
Moyad, Mark A
2004-04-01
Obesity is a recognized epidemic in many regions around the world and billions of dollars are spent each year in attempting to combat this problem. However, before a discussion of the different conventional and alternative treatments for obesity can be initiated, it is first critical to determine whether or not a certain individual is actually overweight, obese, or has an excess of adipose tissue. Therefore, a review of the various popular and unpopular measurements of obesity is needed. A variety of measurements exist such as bioelectrical impedance, body mass index (BMI), crude weight, densitometry, dual energy x-ray absorptiometry (DEXA), lean body mass (LBM), skinfold thickness, and waist-to-hip ratio (WHR). All of these measurements contain inherent advantages and disadvantages, but many of these can still be used in a clinical setting. Health professionals should acquaint themselves with these different measurements in order to take the first step in bringing attention to and potentially treating a condition that affects virtually every medical discipline.
Bioelectricity-AQA, one of the first MOOC courses in engineering.
Barr, Roger C
2014-01-01
Bioelectricity-AQA was one of the first massively open online courses in engineering, having been given the first time via Coursera starting in September, 2012. This report provides some detail on its background, presentation, enrollment, and lessons learned.
NASA Astrophysics Data System (ADS)
Tang, Li-Ming; Chang, Ben-Kang; Liu, Tie-Bing; Wu, Min; Ling, Gang
2002-12-01
To design a new type of circuit for measuring frequency & duty cycle of stimulated bioelectrical signal for the project of 'the map of neuron-threshold in human brain and its clinical application'. This circuit was designed according to the character of stimulated bioelectrical signals. It was tested and improved and then used in the neuron -threshold stimulator. The circuit was found to be very accurate for measuring frequency and the error for measuring duty cycle was below 0.2%. This circuit is well-designed, simple, easy to use, and can be applied in many systems.
Słupska, Lucyna
2013-01-01
Objectives. The main objective was to determine how the depth of probe placement affects functional and resting bioelectrical activity of the PFM and whether the recorded signal might be dependent on the direction in which the probe is rotated. Participants. The study comprised of healthy, nulliparous women between the ages of 21 and 25. Outcome Measures. Bioelectric activity of the PFM was recorded from four locations of the vagina by surface EMG and vaginal probe. Results. There were no statistically significant differences between the results during functional sEMG activity. During resting sEMG activity, the highest bioelectrical activity of the PFM was observed in the L1 and the lowest in the L4 and a statistically significant difference between the highest and the lowest results of resting sEMG activity was observed (P = 0.0043). Conclusion. Different electrodes placement during functional contraction of PFM does not affect the obtained results in sEMG evaluation. In order to diagnose the highest resting activity of PFM the recording plates should be placed toward the anterior vaginal wall and distally from the introitus. However, all of the PFM have similar bioelectrical activity and it seems that these muscles could be treated as a single muscle. PMID:24392449
Nutritional and metabolic status of breast cancer women.
Bering, Tatiana; Maurício, Sílvia Fernandes; Silva, Jacqueline Braga da; Correia, Maria Isabel Toulson Davisson
2014-09-28
The nutritional and metabolic status have been related to cancer risk factors as well as to cancer treatment morbimortality. Thus, its assessment is important for developing strategies for the promotion, maintenance and / or recovery of nutritional status and cancer outcome. Several different methods for nutritional assessment in breast cancer patients undergoing adjuvant therapy were used, including subjective global assessment (SGA), body mass index (BMI), triceps skinfold (TSF), mid-arm circumference (MAC), adductor pollicis muscle thickness (APMT), hand grip strength (HGS) and bioelectrical impedance analysis (BIA). The presence of metabolic syndrome (MetS) was also evaluated. The occurrence of complications during cancer treatment versus the nutritional status was assessed. We followed 78 women with a mean age of 53.2 } 11.6 years. Most patients were considered well nourished (80.8%). Excessive body fat mass by BIA and MetS were found in 80,8 % and 41.9% of the patients respectively. There were significant differences in BMI, TSF, WC (waist circumference) and % fat mass between patients with and without MetS. Most patients experienced complications during cancer treatment, but there was no association with nutritional or metabolic status. In breast cancer women undergoing adjuvant therapy, the prevalence of metabolic syndrome was high and, on the contrary, undernutrition was low. There were no short-term effects of metabolic syndrome or undernutrition on clinical outcomes. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
NASA Astrophysics Data System (ADS)
Gonzalez-Correa, C. H.; Caicedo-Eraso, J. C.; Varon-Serna, D. R.
2013-04-01
The mechanical function and size of a muscle may be closely linked. Handgrip strength (HGS) has been used as a predictor of functional performing. Anthropometric measurements have been made to estimate arm muscle area (AMA) and physical muscle mass volume of upper limb (ULMMV). Electrical volume estimation is possible by segmental BIA measurements of fat free mass (SBIA-FFM), mainly muscle-mass. Relationship among these variables is not well established. We aimed to determine if physical and electrical muscle mass estimations relate to each other and to what extent HGS is to be related to its size measured by both methods in normal or overweight young males. Regression analysis was used to determine association between these variables. Subjects showed a decreased HGS (65.5%), FFM, (85.5%) and AMA (74.5%). It was found an acceptable association between SBIA-FFM and AMA (r2 = 0.60) and poorer between physical and electrical volume (r2 = 0.55). However, a paired Student t-test and Bland and Altman plot showed that physical and electrical models were not interchangeable (pt<0.0001). HGS showed a very weak association with anthropometric (r2 = 0.07) and electrical (r2 = 0.192) ULMMV showing that muscle mass quantity does not mean muscle strength. Other factors influencing HGS like physical training or nutrition require more research.
Weight and Body Composition Changes During Oral Contraceptive Use in Obese and Normal Weight Women
Torgal, Anupama H.; Westhoff, Carolyn L.
2014-01-01
Abstract Background: Oral contraceptive (OC) use seems to have little effect on weight change in normal weight women. Most previous studies have excluded obese women, so the effect of OC use on weight change in obese women is unknown. Methods: This analysis evaluates weight and body composition change with OC use among obese (body mass index [BMI] 30.0–39.9) and normal weight (BMI 19.0–24.9) women who were randomly assigned to two OC doses: 20 μg ethinyl estradiol (EE) and 100 μg levonorgestrel (LNG) OCs or 30 μg EE and 150 μg LNG OCs. Follow-up occurred after three to four OC cycles. Weight and body composition were measured at baseline and at follow-up using a bioelectrical impedance analyzer. Results: Among 150 women (54 obese and 96 normal weight) who used OCs for 3 to 4 months, there were no clinically or statistically significant weight or body composition changes in the overall group or by BMI or OC formulation group. Conclusions: These findings add to evidence that EE/LNG OCs are not associated with short term weight or body composition change for normal weight women and suggest that OCs are also are not associated with short term weight or body composition change in obese women. PMID:24156617
UCP1 and UCP3 Expression Is Associated with Lipid and Carbohydrate Oxidation and Body Composition
Oliveira, Bruno A. P.; Pinhel, Marcela A. S.; Nicoletti, Carolina F.; Oliveira, Cristiana C.; Quinhoneiro, Driele C. G.; Noronha, Natália Y.; Marchini, Júlio S.; Marchry, Ana J.; Junior, Wilson S.; Nonino, Carla B.
2016-01-01
Background/Objective Uncoupling proteins (UCPs) are located in the inner membrane of mitochondria. These proteins participate in thermogenesis and energy expenditure. This study aimed to evaluate how UCP1 and UCP3 expression influences substrate oxidation and elicits possible changes in body composition in patients submitted to bariatric surgery. Subjects/Methods This is a longitudinal study comprising 13 women with obesity grade III that underwent bariatric surgery and 10 healthy weight individuals (control group). Body composition was assessed by bioelectrical impedance. Carbohydrate and fat oxidation was determined by indirect calorimetry. Subcutaneous adipose tissue was collected for gene expression analysis. QPCR was used to evaluate UCP1 and UCP3 expression. Results Obese patients and the control group differed significantly in terms of lipid and carbohydrate oxidation. Six months after bariatric surgery, the differences disappeared. Lipid oxidation correlated with the percentage of fat mass in the postoperative period. Multiple linear regression analysis showed that the UCP1 and UCP3 genes contributed to lipid and carbohydrate oxidation. Additionally, UCP3 expression was associated with BMI, percentage of lean body mass, and percentage of mass in the postoperative period. Conclusions UCP1 and UCP3 expression is associated with lipid and carbohydrate oxidation in patients submitted to bariatric surgery. In addition, UCP3 participates in body composition modulation six months postoperatively. PMID:26959981
Body composition: A predictive factor of cycle fecundity
Kayatas, Semra; Api, Murat; Kurt, Didar; Eroglu, Mustafa; Arınkan, Sevcan Arzu
2014-01-01
Objective To study the effect of body composition on reproduction in women with unexplained infertility treated with a controlled ovarian hyperstimulation and intrauterine insemination programme. Methods This prospective observational study was conducted on 308 unexplained infertile women who were scheduled for a controlled ovarian hyperstimulation and intrauterine insemination programme and were grouped as pregnant and non-pregnant. Anthropometric measurements were performed using TANITA-420MA before the treatment cycle. Body composition was determined using a bioelectrical impedance analysis system. Results Body fat mass was significantly lower in pregnant women than in non-pregnant women (15.61±3.65 vs.18.78±5.97, respectively) (p=0.01). In a multiple regression analysis, body fat mass proved to have a stronger association with fecundity than the percentage of body fat, body mass index, or the waist/hip ratio (standardized regression coefficient≥0.277, t-value≥2.537; p<0.05). The cut-off value of fat mass, which was evaluated using the receiver operating characteristics curve, was 16.65 with a sensitivity of 61.8% and a specificity of 70.2%. Below this cut-off value, the odds of the pregnancy occurrence was found to be 2.5 times more likely. Conclusion Body fat mass can be predictive for pregnancy in patients with unexplained infertility scheduled for a controlled ovarian hyperstimulation and intrauterine insemination programme. PMID:25045631
de Oliveira, Fernanda Cristina Esteves; Alves, Raquel Duarte Moreira; Zuconi, Carolina Pereira; Ribeiro, Andréia Queiroz; Bressan, Josefina
2012-09-01
Predictive equations and methods tend to overestimate or underestimate resting energy expenditure (REE) compared with indirect calorimetry (IC). This cross-sectional study aimed to evaluate the agreement between methods and equations for REE estimation of overweight and obese Brazilian men. Data from 48 healthy volunteers, ages 20 to 43 years and with body mass index ranging from 26.4 to 35.2, were collected between October 2008 and October 2009. REE was measured by IC, using Deltatrac (IC1) and KORR-MetaCheck (IC2) devices. It was estimated by bioelectrical impedance analysis (BIA) using tetrapolar (BIA1) and bipolar (BIA2) devices, and by the equations of Mifflin, World Health Organization/Food and Agriculture Organization/United Nations University, Fleisch, Horie-Waitzberg and Gonzalez, and Ireton-Jones. The association and agreement among the methods and equations were assessed by the interclass correlation coefficient, Bland-Altman analysis, and by the percentage of the difference between values obtained from the standard method and alternative methods and equations. Most methods showed high agreement with IC1. The highest agreements were found for Mifflin (-2.14%), Fleisch (-3.05%), Horie-Waitzberg and Gonzalez (4.41%), and BIA2 (5.25%). Similar results were shown by the Bland-Altman analyses. BIA2, followed by BIA1, Ireton-Jones, Mifflin, and Fleisch, showed the highest association with IC1. Thus, the Mifflin, Fleisch, Horie-Waitzberg and Gonzalez equations, and BIA2, were the most accurate methods for REE estimation in this study. However, because those equations have shown considerable variability, they should be used cautiously. In addition, the IC2 was not found to be an accurate method for REE estimation in overweight and obese men included in this study. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Bioelectricity-AQA, one of the first MOOC courses in Engineering
Barr, Roger C.
2014-01-01
Bioelectricity-AQA was one of the first massively open online courses in engineering, having been given the first time via Coursera starting in September, 2012. This report provides some detail on its background, presentation, enrollment, and lessons learned. PMID:25570327
Liu, Ye; Zhang, Baogang; Tian, Caixing; Feng, Chuanping; Wang, Zhijun; Cheng, Ming; Hu, Weiwu
2016-01-01
Factors influencing the performance of a continual-flow bioelectrical reactor (BER) intensified by microbial fuel cells for groundwater nitrate removal, including nitrate load, carbon source and hydraulic retention time (HRT), were investigated and optimized by response surface methodology (RSM). With the target of maximum nitrate removal and minimum intermediates accumulation, nitrate load (for nitrogen) of 60.70 mg/L, chemical oxygen demand (COD) of 849.55 mg/L and HRT of 3.92 h for the BER were performed. COD was the dominant factor influencing performance of the system. Experimental results indicated the undistorted simulation and reliable optimized values. These demonstrate that RSM is an effective method to evaluate and optimize the nitrate-reducing performance of the present system and can guide mathematical models development to further promote its practical applications.
NASA Astrophysics Data System (ADS)
Hao, Liting; Zhang, Baogang; Tian, Caixing; Liu, Ye; Shi, Chunhong; Cheng, Ming; Feng, Chuanping
2015-08-01
Bioelectricity generated from the microbial fuel cell (MFC) is applied to the bioelectrical reactor (BER) directly to enhance microbial reduction of vanadium (V) (V(V)) in groundwater. With the maximum power density of 543.4 mW m-2 from the MFC, V(V) removal is accelerated with efficiency of 93.6% during 12 h operation. Higher applied voltage can facilitate this process. V(V) removals decrease with the increase of initial V(V) concentration, while extra addition of chemical oxygen demand (COD) has little effect on performance improvement. Microbial V(V) reduction is enhanced and then suppressed with the increase of conductivity. High-throughput 16S rRNA gene pyrosequencing analysis implies the accumulated Enterobacter and Lactococcus reduce V(V) with products from fermentative microorganisms such as Macellibacteroides. The presentation of electrochemically active bacteria as Enterobacter promotes electron transfers. This study indicates that application of bioelectricity from MFCs is a promising strategy to improve the efficiency of in-situ bioremediation of V(V) polluted groundwater.
Koda, M; Ando, F; Niino, N; Tsuzuku, S; Shimokata, H
2000-04-01
Air displacement plethysmography (ADP) is a method for the determining percent body fat (%BF) using the two-compartment model, in which the body is partitioned into body-fat mass and fat-free mass (FFM). Although this model assumes a constant density of FFM as 1.10 g/ml, its density may depend upon the bone mineral content (BMC) and total body water (TBW) which vary with age, gender, and race/ethnicity. This study compared %BF determined from ADP (ADP%BF) with %BF obtained by dual-energy x-ray absorptiometry (DXA%BF), and also investigated the effects of BMC, TBW, and other factors on its value. The subjects were 721 female and male Japanese aged 40 to 79 years. Body density was measured by ADP and %BF was calculated using Brozek et al's equation. BMC and body-fat volume were measured using DXA, and TBW was measured by multifrequency bioelectrical impedance. A series of anthropometric measurements was taken. Although ADP%BF was highly correlated with DXA%BF (female: r = 0.89, male: r = 0.90) (p < 0.001), ADP%BF differed significantly from DXA%BF (female: -1.30 +/- 0.14% (mean +/- s.e.m.), male: 1.22 +/- 0.13%) (p < 0.001). The difference in %BF (ADP%BF-DXA%BF) was negatively associated with BMC/FFM but not with TBW/FFM in both genders. The difference in %BF was also positively correlated with waist circumference. Considering previous studies, this result may be explained by the underestimation of DXA%BF, rather than by the overestimation of ADP%BF. In conclusion, ADP may be a useful method to measure %BF. However, BMC should be taken into consideration. Furthermore, DXA%BF may be underestimated in people with large waists.
More physically active and leaner adolescents have higher energy intake.
Cuenca-García, Magdalena; Ortega, Francisco B; Ruiz, Jonatan R; Labayen, Idoia; Moreno, Luis A; Patterson, Emma; Vicente-Rodríguez, Germán; González-Gross, Marcela; Marcos, Ascensión; Polito, Angela; Manios, Yannis; Beghin, Laurent; Huybrechts, Inge; Wästlund, Acki; Hurtig-Wennlöf, Anita; Hagströmer, Maria; Molnár, Dénes; Widhalm, Kurt; Kafatos, Anthony; De Henauw, Stefaan; Castillo, Manuel J; Gutin, Bernard; Sjöström, Michael
2014-01-01
To test whether youths who engage in vigorous physical activity are more likely to have lean bodies while ingesting relatively large amounts of energy. For this purpose, we studied the associations of both physical activity and adiposity with energy intake in adolescents. The study subjects were adolescents who participated in 1 of 2 cross-sectional studies, the Healthy Lifestyle in Europe by Nutrition in Adolescence (HELENA) study (n = 1450; mean age, 14.6 years) or the European Youth Heart Study (EYHS; n = 321; mean age, 15.6 years). Physical activity was measured by accelerometry, and energy intake was measured by 24-hour recall. In the HELENA study, body composition was assessed by 2 or more of the following methods: skinfold thickness, bioelectrical impedance analysis, plus dual-energy X-ray absorptiometry or air-displacement plethysmography in a subsample. In the EYHS, body composition was assessed by skinfold thickness. Fat mass was inversely associated with energy intake in both studies and using 4 different measurement methods (P ≤ .006). Overall, fat-free mass was positively associated with energy intake in both studies, yet the results were not consistent across measurement methods in the HELENA study. Vigorous physical activity in the HELENA study (P < .05) and moderate physical activity in the EYHS (P < .01) were positively associated with energy intake. Overall, results remained unchanged after adjustment for potential confounding factors, after mutual adjustment among the main exposures (physical activity and fat mass), and after the elimination of obese subjects, who might tend to underreport energy intake, from the analyses. Our data are consistent with the hypothesis that more physically active and leaner adolescents have higher energy intake than less active adolescents with larger amounts of fat mass. Copyright © 2014 Mosby, Inc. All rights reserved.
CUTOFF POINT OF THE PHASE ANGLE IN PRE-RADIOTHERAPY CANCER PATIENTS.
Souza Thompson Motta, Rachel; Alves Castanho, Ivany; Guillermo Coca Velarde, Luis
2015-11-01
malnutrition is a common complication for cancer patients. The phase angle (PA), direct measurement of bioelectrical impedance analysis (BIA), has been considered a predictor of body cell mass and prognostic indicator. Cutoff points for phase angle (PA) associated with nutritional risk in cancer patients have not been determined yet. assess the possibility of determining the cutoff point for PA to identify nutritional risk in pre-radiotherapy cancer patients. sample group: Patients from both genders diagnosed with cancer and sent for ambulatory radiotherapy. body mass index (BMI), percentage of weight loss (% WL), mid-arm circumference (MAC), triceps skinfold thickness (TST), mid-arm muscle circumference (MAMC), mid-arm muscle area (MAMA), score and categorical assessment obtained using the Patient-Generated Subjective Global Assessment (PG-SGA) form, PA and standardized phase angle (SPA). Kappa coefficient was used to test the degree of agreement between the diagnoses of nutritional risk obtained from several different methods of nutritional assessment. Cutoff points for the PA through anthropometric indicators and PG-SGA were determined by using Receiver Operating Characteristic (ROC) curves, and patient survival was analyzed with the Cox regression method. the cutoff points with the greatest discriminatory power were those obtained from BMI (5.2) and the categorical assessment of PG-SGA (5.4). The diagnosis obtained using these cutoff points showed a significant association with risk of death for the patients in the sample group. we recommend using the cutoff point 5.2 for the PA as a criterion for identifying nutritional risk in pre-radiotherapy cancer patients. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Bioelectrical coupling in multicellular domains regulated by gap junctions: A conceptual approach.
Cervera, Javier; Pietak, Alexis; Levin, Michael; Mafe, Salvador
2018-04-21
We review the basic concepts involved in bioelectrically-coupled multicellular domains, focusing on the role of membrane potentials (V mem ). In the first model, single-cell V mem is modulated by two generic polarizing and depolarizing ion channels, while intercellular coupling is implemented via voltage-gated gap junctions. Biochemical and bioelectrical signals are integrated via a feedback loop between V mem and the transcription and translation of a protein forming an ion channel. The effective rate constants depend on the single-cell V mem because these potentials modulate the local concentrations of signaling molecules and ions. This electrochemically-based idealization of the complex biophysical problem suggests that the spatio-temporal map of single-cell potentials can influence downstream patterning processes by means of the voltage-gated gap junction interconnectivity, much as in the case of electronic devices where the control of electric potentials and currents allows the local modulation of the circuitry to achieve full functionality. An alternative theoretical approach, the BioElectrical Tissue Simulation Engine (BETSE), is also presented. The BETSE modeling environment utilizes finite volume techniques to simulate bioelectric states from the perspective of ion concentrations and fluxes. This model has been successfully applied to make predictions and explain experimental observations in a variety of embryonic, regenerative, and oncogenic contexts. Copyright © 2018 Elsevier B.V. All rights reserved.
[Detection of constitutional types of EEG using the orthogonal decomposition method].
Kuznetsova, S M; Kudritskaia, O V
1987-01-01
The authors present an algorithm of investigation into the processes of brain bioelectrical activity with the help of an orthogonal decomposition device intended for the identification of constitutional types of EEGs. The method has helped to effectively solve the task of the diagnosis of constitutional types of EEGs, which are determined by a variable degree of hereditary predisposition for longevity or cerebral stroke.
Modified coaxial wire method for measurement of transfer impedance of beam position monitors
NASA Astrophysics Data System (ADS)
Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.
2018-05-01
The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.
NASA Astrophysics Data System (ADS)
Li, J.; Rutkove, S. B.
2013-04-01
Electrical impedance myography (EIM) is a bioelectrical impedance technique focused on the assessment of neuromuscular diseases using tetrapolar surface arrays. Recently, we have shown that reproducible and sensitive EIM measurements can be made on the gastrocnemius muscle of the mouse hind limb and that these are sensitive to disease alterations. A dedicated array would help speed data acquisition and provide additional sensitivity to disease-induced alterations. A flexible electrode array was developed with electrode sizes of 1mm × 1mm by Parlex, Inc. Tetrapolar electrode sets were arranged both parallel to (longitudinal) and orthogonally to (transverse) the major muscle fiber direction of the gastrocnemius muscle. Measurements were made with a dedicated EIM system. A total of 11 healthy animals and 7 animals with spinal muscular atrophy (a form of motor neuron disease) were evaluated after the fur was completely removed with a depilatory agent from the hind limb. Standard electrophysiologic testing (compound motor action potential amplitude and motor unit number estimation) was also performed. The flexible electrode array demonstrated high repeatability in both the longitudinal and transverse directions in the healthy and diseased animals (with intraclass correlation coefficients of 0.94 and 0.89, respectively, for phase angle measured transversely). In addition, differences between healthy and diseased animals were identifiable. For example, the 50 kHz transverse phase angle was higher in the healthy as compared to the SMA animals (16.8° ± 0.5 vs. 14.3° ± 0.7, respectively) at 21 weeks of age (p = 0.01). Differences in anisotropy were also identifiable. Correlations to several standard neurophysiologic parameters also appeared promising. This novel flexible tetrapolar electrode array can be used on the mouse hind limb and provides multidirectional data that can be used to assess muscle health. This technique has the potential of finding widespread use in the evaluation of drug therapies in neuromuscular animal disease models.
Low-noise two-wired buffer electrodes for bioelectric amplifiers.
Degen, Thomas; Torrent, Simon; Jäckel, Heinz
2007-07-01
Active buffer electrodes are known to improve the immunity of bioelectric recordings against power line interferences. A survey of published work reveals that buffer electrodes are almost exclusively designed using operational amplifiers (opamps). In this paper, we discuss the advantage of utilizing a single transistor instead. This allows for a simple electrode, which is small and requires only two wires. In addition, a single transistor adds considerably less noise when compared to an opamp with the same power consumption. We then discuss output resistance and gain as well as their respective effect on the common mode rejection ratio (CMRR). Finally, we demonstrate the use of two-wired buffer electrodes for a bioelectric amplifier.
Cellular water distribution, transport, and its investigation methods for plant-based food material.
Khan, Md Imran H; Karim, M A
2017-09-01
Heterogeneous and hygroscopic characteristics of plant-based food material make it complex in structure, and therefore water distribution in its different cellular environments is very complex. There are three different cellular environments, namely the intercellular environment, the intracellular environment, and the cell wall environment inside the food structure. According to the bonding strength, intracellular water is defined as loosely bound water, cell wall water is categorized as strongly bound water, and intercellular water is known as free water (FW). During food drying, optimization of the heat and mass transfer process is crucial for the energy efficiency of the process and the quality of the product. For optimizing heat and mass transfer during food processing, understanding these three types of waters (strongly bound, loosely bound, and free water) in plant-based food material is essential. However, there are few studies that investigate cellular level water distribution and transport. As there is no direct method for determining the cellular level water distributions, various indirect methods have been applied to investigate the cellular level water distribution, and there is, as yet, no consensus on the appropriate method for measuring cellular level water in plant-based food material. Therefore, the main aim of this paper is to present a comprehensive review on the available methods to investigate the cellular level water, the characteristics of water at different cellular levels and its transport mechanism during drying. The effect of bound water transport on quality of food product is also discussed. This review article presents a comparative study of different methods that can be applied to investigate cellular water such as nuclear magnetic resonance (NMR), bioelectric impedance analysis (BIA), differential scanning calorimetry (DSC), and dilatometry. The article closes with a discussion of current challenges to investigating cellular water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Imaging electric field dynamics with graphene optoelectronics.
Horng, Jason; Balch, Halleh B; McGuire, Allister F; Tsai, Hsin-Zon; Forrester, Patrick R; Crommie, Michael F; Cui, Bianxiao; Wang, Feng
2016-12-16
The use of electric fields for signalling and control in liquids is widespread, spanning bioelectric activity in cells to electrical manipulation of microstructures in lab-on-a-chip devices. However, an appropriate tool to resolve the spatio-temporal distribution of electric fields over a large dynamic range has yet to be developed. Here we present a label-free method to image local electric fields in real time and under ambient conditions. Our technique combines the unique gate-variable optical transitions of graphene with a critically coupled planar waveguide platform that enables highly sensitive detection of local electric fields with a voltage sensitivity of a few microvolts, a spatial resolution of tens of micrometres and a frequency response over tens of kilohertz. Our imaging platform enables parallel detection of electric fields over a large field of view and can be tailored to broad applications spanning lab-on-a-chip device engineering to analysis of bioelectric phenomena.
Ptaszkowski, Kuba; Paprocka-Borowicz, Małgorzata; Słupska, Lucyna; Bartnicki, Janusz; Dymarek, Robert; Rosińczuk, Joanna; Heimrath, Jerzy; Dembowski, Janusz; Zdrojowy, Romuald
2015-01-01
Objective Muscles such as adductor magnus (AM), gluteus maximus (GM), rectus abdominis (RA), and abdominal external and internal oblique muscles are considered to play an important role in the treatment of stress urinary incontinence (SUI), and the relationship between contraction of these muscles and pelvic floor muscles (PFM) has been established in previous studies. Synergistic muscle activation intensifies a woman’s ability to contract the PFM. In some cases, even for continent women, it is not possible to fully contract their PFM without involving the synergistic muscles. The primary aim of this study was to assess the surface electromyographic activity of synergistic muscles to PFM (SPFM) during resting and functional PFM activation in postmenopausal women with and without SUI. Materials and methods This study was a preliminary, prospective, cross-sectional observational study and included volunteers and patients who visited the Department and Clinic of Urology, University Hospital in Wroclaw, Poland. Forty-two patients participated in the study and were screened for eligibility criteria. Thirty participants satisfied the criteria and were categorized into two groups: women with SUI (n=16) and continent women (n=14). The bioelectrical activity of PFM and SPFM (AM, RA, GM) was recorded with a surface electromyographic instrument in a standing position during resting and functional PFM activity. Results Bioelectrical activity of RA was significantly higher in the incontinent group than in the continent group. These results concern the RA activity during resting and functional PFM activity. The results for other muscles showed no significant difference in bioelectrical activity between groups. Conclusion In women with SUI, during the isolated activation of PFM, an increased synergistic activity of RA muscle was observed; however, this activity was not observed in asymptomatic women. This may indicate the important accessory contribution of these muscles in the mechanism of continence. PMID:26445533
ERIC Educational Resources Information Center
Rodriguez-Falces, Javier
2013-01-01
In electrophysiology studies, it is becoming increasingly common to explain experimental observations using both descriptive methods and quantitative approaches. However, some electrophysiological phenomena, such as the generation of extracellular potentials that results from the propagation of the excitation source along the muscle fiber, are…
Determining blood and plasma volumes using bioelectrical response spectroscopy
NASA Technical Reports Server (NTRS)
Siconolfi, S. F.; Nusynowitz, M. L.; Suire, S. S.; Moore, A. D. Jr; Leig, J.
1996-01-01
We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.
NASA Astrophysics Data System (ADS)
Shibata, Shin-Ichi; Satou, Fumitake; Kimura, Haruhiko; Oyabu, Takashi
Recently, there is a problem of the steady supply of food therefore plant factory has been establishing and takes off in world wide countries. In the plant factory, the growing environment can be controlled and the crop can also be controlled. The products are growing in an enclosed environment, therefore agricultural chemicals has no use. Secure and safe food producing system can be constructed. However, efficient production formula for the plant (for example vegetable) is not defined well. It is an effective way to control the growing environmental factors using physiology information which are directly obtained from the vegetable. The chlorophyll fluorescence is used as evaluation of plant condition. It is necessary to clarify the bioelectric potential in the growth condition of the plant. In this study, we examined the relationship between the chlorophyll fluorescence and the plant bioelectric potential in bad condition. The plant in spraying chemical herbicides was assumed as the condition. In future, plant physiological function and environmental response can be understood by directly monitoring the bioelectric potential.
Bioelectric Control of a 757 Class High Fidelity Aircraft Simulation
NASA Technical Reports Server (NTRS)
Jorgensen, Charles; Wheeler, Kevin; Stepniewski, Slawomir; Norvig, Peter (Technical Monitor)
2000-01-01
This paper presents results of a recent experiment in fine grain Electromyographic (EMG) signal recognition, We demonstrate bioelectric flight control of 757 class simulation aircraft landing at San Francisco International Airport. The physical instrumentality of a pilot control stick is not used. A pilot closes a fist in empty air and performs control movements which are captured by a dry electrode array on the arm, analyzed and routed through a flight director permitting full pilot outer loop control of the simulation. A Vision Dome immersive display is used to create a VR world for the aircraft body mechanics and flight changes to pilot movements. Inner loop surfaces and differential aircraft thrust is controlled using a hybrid neural network architecture that combines a damage adaptive controller (Jorgensen 1998, Totah 1998) with a propulsion only based control system (Bull & Kaneshige 1997). Thus the 757 aircraft is not only being flown bioelectrically at the pilot level but also demonstrates damage adaptive neural network control permitting adaptation to severe changes in the physical flight characteristics of the aircraft at the inner loop level. To compensate for accident scenarios, the aircraft uses remaining control surface authority and differential thrust from the engines. To the best of our knowledge this is the first time real time bioelectric fine-grained control, differential thrust based control, and neural network damage adaptive control have been integrated into a single flight demonstration. The paper describes the EMG pattern recognition system and the bioelectric pattern recognition methodology.
Carbon fiber enhanced bioelectricity generation in soil microbial fuel cells.
Li, Xiaojing; Wang, Xin; Zhao, Qian; Wan, Lili; Li, Yongtao; Zhou, Qixing
2016-11-15
The soil microbial fuel cell (MFC) is a promising biotechnology for the bioelectricity recovery as well as the remediation of organics contaminated soil. However, the electricity production and the remediation efficiency of soil MFC are seriously limited by the tremendous internal resistance of soil. Conductive carbon fiber was mixed with petroleum hydrocarbons contaminated soil and significantly enhanced the performance of soil MFC. The maximum current density, the maximum power density and the accumulated charge output of MFC mixed carbon fiber (MC) were 10, 22 and 16 times as high as those of closed circuit control due to the carbon fiber productively assisted the anode to collect the electron. The internal resistance of MC reduced by 58%, 83% of which owed to the charge transfer resistance, resulting in a high efficiency of electron transfer from soil to anode. The degradation rates of total petroleum hydrocarbons enhanced by 100% and 329% compared to closed and opened circuit controls without the carbon fiber respectively. The effective range of remediation and the bioelectricity recovery was extended from 6 to 20cm with the same area of air-cathode. The mixed carbon fiber apparently enhanced the bioelectricity generation and the remediation efficiency of soil MFC by means of promoting the electron transfer rate from soil to anode. The use of conductively functional materials (e.g. carbon fiber) is very meaningful for the remediation and bioelectricity recovery in the bioelectrochemical remediation. Copyright © 2016 Elsevier B.V. All rights reserved.
Saz, Çağdaş; Türe, Cengiz; Türker, Onur Can; Yakar, Anıl
2018-03-01
An operation of microcosm-constructed wetland modules combined with microbial fuel cell device (CW-MFC) was assessed for wastewater treatment and bioelectric generation. One of the crucial aims of the present experiment is also to determine effect of vegetation on wastewater treatment process and bioelectric production in wetland matrix with microbial fuel cell. Accordingly, CW-MFC modules with vegetation had higher treatment efficiency compared to unplanted wetland module, and average COD, NH 4 + , and TP removal efficiency in vegetated wetland modules were ranged from 85 to 88%, 95 to 97%, and 95 to 97%, respectively. However, the highest NO 3 - removal (63%) was achieved by unplanted control module during the experiment period. The maximum average output voltage, power density, and Coulombic efficiency were obtained in wetland module vegetated with Typha angustifolia for 1.01 ± 0.14 V, 7.47 ± 13.7 mWatt/m 2 , and 8.28 ± 10.4%, respectively. The results suggest that the presence of Typha angustifolia vegetation in the CW-MFC matrix provides the benefits for treatment efficiency and bioelectric production; thus, it increases microbial activities which are responsible for biodegradation of organic compounds and catalyzed to electron flow from anode to cathode. Consequently, we suggest that engineers can use vegetated wetland matrix with Typha angustifolia in CW-MFC module in order to maximize treatment efficiency and bioelectric production.
Rodriguez-Falces, Javier
2013-12-01
In electrophysiology studies, it is becoming increasingly common to explain experimental observations using both descriptive methods and quantitative approaches. However, some electrophysiological phenomena, such as the generation of extracellular potentials that results from the propagation of the excitation source along the muscle fiber, are difficult to describe and conceptualize. In addition, most traditional approaches aimed at describing extracellular potentials consist of complex mathematical machinery that gives no chance for physical interpretation. The aim of the present study is to present a new method to teach the formation of extracellular potentials around a muscle fiber from both a descriptive and quantitative perspective. The implementation of this method was tested through a written exam and a satisfaction survey. The new method enhanced the ability of students to visualize the generation of bioelectrical potentials. In addition, the new approach improved students' understanding of how changes in the fiber-to-electrode distance and in the shape of the excitation source are translated into changes in the extracellular potential. The survey results show that combining general principles of electrical fields with accurate graphic imagery gives students an intuitive, yet quantitative, feel for electrophysiological signals and enhances their motivation to continue their studies in the biomedical engineering field.
Effects of Liner Length and Attenuation on NASA Langley Impedance Eduction
NASA Technical Reports Server (NTRS)
Jones, M. G.; Watson, W. R.
2016-01-01
This study explores the effects of liner length and attenuation on the CHE (convected Helmholtz equation) impedance eduction method, in which the surface impedance of an acoustic liner is inferred through an iterative process based on repeated solutions to the convected Helmholtz equation. Wire mesh-over-honeycomb and perforate-over-honeycomb acoustic liners are tested in the NASA Langley Grazing Flow Impedance Tube, and the resultant data are processed using two impedance eduction methods. The first is the CHE method, and the second is a direct method (labeled the KT method) that uses the Kumaresan and Tufts algorithm to compute the impedance directly. The CHE method has been extensively used for acoustic liner evaluation, but experiences anomalous behavior under some test conditions. It is postulated that the anomalies are related to the liner length and/or attenuation. Since the KT method only employs data measured over the length of the liner, it is expected to be unaffected by liner length. A comparison of results achieved with the two impedance eduction methods is used to explore the interactive effects of liner length and attenuation on the CHE impedance eduction method.
Bioelectric memory: modeling resting potential bistability in amphibian embryos and mammalian cells.
Law, Robert; Levin, Michael
2015-10-15
Bioelectric gradients among all cells, not just within excitable nerve and muscle, play instructive roles in developmental and regenerative pattern formation. Plasma membrane resting potential gradients regulate cell behaviors by regulating downstream transcriptional and epigenetic events. Unlike neurons, which fire rapidly and typically return to the same polarized state, developmental bioelectric signaling involves many cell types stably maintaining various levels of resting potential during morphogenetic events. It is important to begin to quantitatively model the stability of bioelectric states in cells, to understand computation and pattern maintenance during regeneration and remodeling. To facilitate the analysis of endogenous bioelectric signaling and the exploitation of voltage-based cellular controls in synthetic bioengineering applications, we sought to understand the conditions under which somatic cells can stably maintain distinct resting potential values (a type of state memory). Using the Channelpedia ion channel database, we generated an array of amphibian oocyte and mammalian membrane models for voltage evolution. These models were analyzed and searched, by simulation, for a simple dynamical property, multistability, which forms a type of voltage memory. We find that typical mammalian models and amphibian oocyte models exhibit bistability when expressing different ion channel subsets, with either persistent sodium or inward-rectifying potassium, respectively, playing a facilitative role in bistable memory formation. We illustrate this difference using fast sodium channel dynamics for which a comprehensive theory exists, where the same model exhibits bistability under mammalian conditions but not amphibian conditions. In amphibians, potassium channels from the Kv1.x and Kv2.x families tend to disrupt this bistable memory formation. We also identify some common principles under which physiological memory emerges, which suggest specific strategies for implementing memories in bioengineering contexts. Our results reveal conditions under which cells can stably maintain one of several resting voltage potential values. These models suggest testable predictions for experiments in developmental bioelectricity, and illustrate how cells can be used as versatile physiological memory elements in synthetic biology, and unconventional computation contexts.
Greater transportation energy and GHG offsets from bioelectricity than ethanol.
Campbell, J E; Lobell, D B; Field, C B
2009-05-22
The quantity of land available to grow biofuel crops without affecting food prices or greenhouse gas (GHG) emissions from land conversion is limited. Therefore, bioenergy should maximize land-use efficiency when addressing transportation and climate change goals. Biomass could power either internal combustion or electric vehicles, but the relative land-use efficiency of these two energy pathways is not well quantified. Here, we show that bioelectricity outperforms ethanol across a range of feedstocks, conversion technologies, and vehicle classes. Bioelectricity produces an average of 81% more transportation kilometers and 108% more emissions offsets per unit area of cropland than does cellulosic ethanol. These results suggest that alternative bioenergy pathways have large differences in how efficiently they use the available land to achieve transportation and climate goals.
Bioelectric effect and bacterial biofilms. A systematic review
DEL POZO, J. L.; ROUSE, M. S.; PATEL, R.
2014-01-01
Bacteria growing in biofilms cause a wide range of human infections. Biofilm bacteria are resistant to antimicrobics at levels 500 to 5,000 times higher than those needed to kill non-biofilm bacteria. In vitro experiments have shown that electric current can enhance the activity of some antimicrobial agents against certain bacteria in biofilms; this has been termed the “bioelectric effect”. Direct electrical current has already been safely used in humans for fracture healing. Application of direct electric current with antimicrobial chemotherapy in humans could theoretically abrogate the need to remove the device in device-related infections, a procedure associated with substantial morbidity and cost. In this article, we review what has been described in the literature with regards to the bioelectric effect. PMID:18924090
Lee, Shoo Thien; Wong, Jyh Eiin; Shanita, Safii Nik; Ismail, Mohd Noor; Deurenberg, Paul; Poh, Bee Koon
2014-12-23
Childhood obesity is related to low physical activity level and a sedentary lifestyle. The aim of this study was to assess the physical activity level and sedentary behaviour of Malaysian children aged 7 to 12 years and to examine their association with body mass index (BMI), BMI-for-age Z-score (BAZ), body fatness (%BF) and waist circumference (WC). A total of 1736 children, representing all ethnic groups were recruited from six regions of Malaysia. Anthropometric measurements included body weight, height and waist circumference. Body fat percentage (%BF) was assessed using bioelectrical impedance. Physical activity was assessed by a physical activity questionnaire (PAQ) in all children and by pedometers in a subsample (n = 514). PAQ score and pedometer step counts were negatively associated with BMI, BAZ, %BF and WC after adjusting for covariates. Screen time was positively associated with BAZ and WC. However, other sedentary activities were not significantly related with any anthropometric indicators. Strategies to promote active living among children in Malaysia should focus not only on increasing physical activity but also emphasise reduction in sedentary behaviours.
García-Contreras, Andrea A; Vásquez-Garibay, Edgar M; Romero-Velarde, Enrique; Ibarra-Gutiérrez, Ana Isabel; Troyo-Sanromán, Rogelio; Sandoval-Montes, Imelda E
2014-04-01
To demonstrate that a nutritional support intervention, via naso-enteral tube-feeding or gastrostomy, has a significant impact on the nutritional status and body composition in severely malnourished children with cerebral palsy spastic quadriplegia. Thirteen patients with moderate/severe malnutrition and cerebral palsy spastic quadriplegia who were fed via naso-enteral tube-feeding or gastrostomy were included in a cohort study. Anthropometric measurements and estimated body composition by bioelectric impedance analysis were obtained. ANOVA and Wilcoxon tests were used. During the four weeks of nutritional recovery, an average weight increase of 2700 g was achieved. There were significant increases in anthropometric indicators, including BMI and weight/length (p < 0.01). The increase in arm fat area was significantly higher than the increase in arm muscle area (104.5 vs 17.5%). Intensive nutritional support for four weeks had a significant effect on the nutritional status and body composition of severe and moderately malnourished children with cerebral palsy spastic quadriplegia. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Adult obesity: panel study from native Amazonians.
Zeng, Wu; Eisenberg, Dan T A; Jovel, Karla Rubio; Undurraga, Eduardo A; Nyberg, Colleen; Tanner, Susan; Reyes-García, Victoria; Leonard, William R; Castaño, Juliana; Huanca, Tomás; McDade, Thomas W; Godoy, Ricardo
2013-03-01
This paper examines three morphological indicators measuring obesity among a native Amazonian population of foragers-farmers in Bolivia (Tsimane') and estimates the associations between them and standard covariates of obesity (e.g., socioeconomic status [SES]). We collected annual data from 350 non-pregnant women and 385 men ≥20 years of age from all 311 households in 13 villages during five consecutive years (2002-2006). We used three indicators to measure obesity: body-mass index (BMI), waist circumference (WC), and body fat using bioelectrical impedance analysis (BF-BIA). We ran separate individual random-effect panel multiple regressions for women and men with wealth, acculturation, health, and household food availability as key covariates, and controlled for village and year fixed effects and village×year interaction effects. Although BMI increases by a statistically significant annual growth rate of 0.64% among women and 0.37% among men over the five years, the increase does not yield significant biological meanings. Neither do we find consistent and biologically meaningful covariates associated with adult obesity. Copyright © 2012 Elsevier B.V. All rights reserved.
Lee, Shoo Thien; Wong, Jyh Eiin; Nik Shanita, Safii; Ismail, Mohd Noor; Deurenberg, Paul; Poh, Bee Koon
2014-01-01
Childhood obesity is related to low physical activity level and a sedentary lifestyle. The aim of this study was to assess the physical activity level and sedentary behaviour of Malaysian children aged 7 to 12 years and to examine their association with body mass index (BMI), BMI-for-age Z-score (BAZ), body fatness (%BF) and waist circumference (WC). A total of 1736 children, representing all ethnic groups were recruited from six regions of Malaysia. Anthropometric measurements included body weight, height and waist circumference. Body fat percentage (%BF) was assessed using bioelectrical impedance. Physical activity was assessed by a physical activity questionnaire (PAQ) in all children and by pedometers in a subsample (n = 514). PAQ score and pedometer step counts were negatively associated with BMI, BAZ, %BF and WC after adjusting for covariates. Screen time was positively associated with BAZ and WC. However, other sedentary activities were not significantly related with any anthropometric indicators. Strategies to promote active living among children in Malaysia should focus not only on increasing physical activity but also emphasise reduction in sedentary behaviours. PMID:25546277
Aerobic power and anthropometric characteristics of elite basketball referees.
Leicht, A S
2007-03-01
The current study aimed to document the aerobic power and body composition of elite basketball referees. Prior to the 2000/2001 Men's National Basketball League season, 25 male elite referees completed the Multistage Shuttle run test followed by body composition (body fat%) determination via bioelectrical impedance (BI) (Adult and Athlete modes) and a restricted anthropometric profile. Significant correlations between BI and anthropometric measures were examined via Pearson product correlation coefficients. Referees demonstrated a mean (SD) aerobic power of 50.8 (3.2) mL . kg-1 . min(-1) and body fat% of 23.8% (8.4%). Body fat% was similar for BI (Adult) and several anthropometric equations. Significant correlations were obtained between BI (Adult) and body fat%, and BI (Adult) and sum of skinfolds. Similar correlations were obtained for BI (Athlete) mode despite a significantly lower body fat%. Regression equations for the prediction of body fat% and sum of skinfolds from BI (Adult) were determined. Elite basketball referees demonstrated significantly greater aerobic power and similar body composition to the general community. In the euhydrated state, BI (Adult) provided a valid measurement of body fat% in elite basketball referees.
Effect of HIV infection on body composition and fat distribution in Rwandan women.
Mutimura, Eugene; Anastos, Kathryn; Zheng Lin; Cohen, Mardge; Binagwaho, Agnes; Kotler, Donald P
2010-01-01
To assess the association of HIV infection with body weight and composition in Rwandan women. Body weight and composition, the latter determined by bioelectrical impedance analysis (BIA) and by anthropometry, were compared in 620 HIV-positive and 211 HIV-negative participants. Associations of HIV with body composition were assessed, and t tests compared the groups. HIV-positive women were younger (-7.0 years, P < .001) and shorter (-2.1 cm, P < .001). Mean body weight, body mass index (BMI), total body fat, and waist-to-hip ratio (WHR) were similar. Mean fat-free mass was 2.5% greater in HIV-negative participants, and 19% of HIV-positive group had BMI <18.5 kg/m(2) versus 26% of the HIV-negative group (P < .05). CD4 counts and body composition were not associated. Malnutrition was common in this cohort of Rwandan women. However, HIV infection was not associated with nutritional status. Factors other than malnutrition may influence quality-of-life outcomes in HIV-infected Rwandan women. Initiatives to improve nutritional status should be population-wide and not restricted to the HIV-infected population.
Age- and sex-related differences in body composition in healthy subjects aged 18 to 82 years.
He, Xue; Li, Zishuai; Tang, Xunhui; Zhang, Lijun; Wang, Li; He, Yongjun; Jin, Tianbo; Yuan, Dongya
2018-06-01
Significant changes in body composition are known to occur with aging. The aim of the present study was to provide a normative reference of body composition and to investigate age and sex-related differences in healthy subjects by multifrequency bioelectrical impedance analyzer (BIA).A cross-sectional study was conducted on a sample of 3451 healthy Chinese adults, 1611 males and 1840 females. The volunteers were enrolled in 5 different age bands (18-30, 31-40, 41-50, 51-60, 60+). All subjects were measured for weight and height and submitted to BIA, to determine body composition. Body composition measures accounted for differences between men and women.A decrease in fat-free mass and increase in percent body fat was observed with aging, although the phenomenon was proved to be attenuated in women. The central and visceral redistribution of fat mass was also shown along lifetime.This study is a report on body composition of healthy subjects, to be used as an important data for future investigations and differences between nationalities and countries.
Wada, Roy; Tekin, Erdal
2010-07-01
This paper examines the relationship between body composition and wages in the United States. We develop measures of body composition--body fat (BF) and fat-free mass (FFM)--using data on bioelectrical impedance analysis (BIA) that are available in the National Health and Nutrition Examination Survey III and estimate wage models for respondents in the National Longitudinal Survey of Youth 1979. Previous research uses body size or BMI as measures of obesity despite a growing concern that they do not distinguish between body fat and fat-free body mass or adequately control for non-homogeneity inside the human body. Therefore, measures presented in this paper represent a useful alternative to BMI-based proxies of obesity. Our results indicate that BF is associated with decreased wages for both males and females among whites and blacks. We also present evidence suggesting that FFM is associated with increased wages. We show that these results are not the artifacts of unobserved heterogeneity. Finally, our findings are robust to numerous specification checks and to a large number of alternative BIA prediction equations from which the body composition measures are derived. 2010 Elsevier B.V. All rights reserved.
Yuki, Atsumu; Ando, Fujiko; Shimokata, Hiroshi
2014-10-01
Sarcopenia is a syndrome characterized by loss of skeletal muscle mass and function (strength and physical performance) with a risk of adverse outcomes. Asian criteria have been decided recently by the Asia Working Group for Sarcopenia (AWGS) . AWGS defined sarcopenia as low skeletal muscle mass plus low muscle strength and/or low physical performance based on the previous reports. AWGS recommend cutoff values for muscle mass (7.0 kg/m(2) for men and 5.4 kg/m(2) for women by using dual X-ray absorptiometry, and 7.0 kg/m(2) for men and 5.7 kg/m(2) for women by using bioelectrical impedance analysis) , handgrip strength (<26 kg for men and <18 kg for women) , and usual gait speed (<0.8 m/s) . The prevalence of sarcopenia in Japanese elderly men and women diagnosed using Asian criteria was 9.6% and 7.7%, respectively. The estimated number of prevalent cases of sarcopenia in Japanese elderly men and women was approximately 1.3 million and 1.4 million, respectively.
[Physical fitness and motor ability in obese boys 12 through 14 years of age].
Kim, H K; Matsuura, Y; Tanaka, K; Inagaki, A
1993-01-01
Excess body fat has generally been considered to be an influential factor to physical fitness and motor ability in obese boys. However, little information is available on the physical fitness and motor ability in obese boys. The purpose of this study was to clarify characteristics of physical fitness and motor ability in obese boys. The subjects were three hundreds and five boys aged 12-14 years. Nineteen physical fitness and motor ability items were tested and skinfold thickness was measured at six sites. Bioelectrical impedance was measured using a tetrapolar impedance plethysmograph (Selco SIF-891). Body density was calculated from the formula of Kim et al. The results of comparison clearly indicated that the obese group was significantly poorer in 1,500-m run, 5-min run, 50-m run, running long jump and many other variables, but was superior only in back strength. To analyze the factorial structure in boys, principal factor analysis was applied to the correlation matrix which was calculated with 19 variables, and then five factors were extracted. The obese group was significantly poorer in total body endurance and muscular endurance than the non-obese group. From these results, it was confirmed that the excess body fat could be one of the most important factors that affects the state of many physical fitness and motor ability elements in obese boys. However, the relationships between physical fitness, motor ability and the degree of fatness seem to be rather complicated. A great deal of data should be accumulated for more detailed analysis on the influence of the excess body fat in obese boys.
Atherton, Rachel R.; Williams, Jane E.; Wells, Jonathan C. K.; Fewtrell, Mary S.
2013-01-01
Background Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. Objectives (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. Design FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height2/Z)) in 927 subjects aged 3.8–22.0 y (211 healthy, 716 patients). Results DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (±0.62); FFM SDS −0.04 (±0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤−2 or ≥2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. Conclusions DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome. PMID:23690932
Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S
2013-01-01
Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.
Bilgir, Oktay; Gökçen, Belma; Bilgir, Ferda; Guler, Aslı; Calan, Mehmet; Yuksel, Arif; Aslanıpour, Behnaz; Akşit, Murat; Bozkaya, Giray
2018-01-01
Growing evidence suggest that macrophage migration inhibitory factor (MIF) plays a vital role in glucose metabolism. We aimed to ascertain whether MIF levels are altered in subjects with prediabetes and also to determine the relationship between MIF and metabolic parameters as well as visceral fat mass. This cross-sectional study included 40 subjects with prediabetes and 40 age-, body mass index (BMI)- and sex-matched subjects with normal glucose tolerance. Circulating MIF levels were measured using enzyme-linked immunosorbent assay. Metabolic parameters of recruited subjects were evaluated. Visceral fat mass was measured using bioelectrical impedance method. Circulating MIF levels were found to be elevated in subjects with prediabetes compared to controls (26.46 ± 16.98 versus 17.44 ± 11.80 ng/mL, P = 0.007). MIF positively correlated with BMI, visceral fat mass and indirect indices of homeostasis model assessment of insulin resistance. In linear regression model, an independent association was found between MIF levels and metabolic parameters, including BMI, visceral fat mass and homeostasis model assessment of insulin resistance. Multivariate logistic regression analyses revealed that the odds ratio for prediabetes was higher in subjects in the highest quartile of MIF compared to those in the lowest quartile, after adjusting for potential confounders. Increased MIF levels are associated with the elevation of prediabetic risk. Copyright © 2018 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Wong, William W.; Strizich, Garrett; Heo, Moonseong; Heymsfield, Steven B.; Himes, John H.; Rock, Cheryl L.; Gellman, Marc D.; Siega-Riz, Anna Maria; Sotres-Alvarez, Daniela; Davis, Sonia M.; Arredondo, Elva M.; Van Horn, Linda; Wylie-Rosett, Judith; Sanchez-Johnsen, Lisa; Kaplan, Robert; Mossavar-Rahmani, Yasmin
2016-01-01
Objective To evaluate the percentage of body fat (%BF)-BMI relationship, identify %BF levels corresponding to adult BMI cut-points, and examine %BF-BMI agreement in a diverse Hispanic/Latino population. Methods %BF by bioelectrical impedance analysis (BIA) was corrected against %BF by 18O dilution in 476 participants of the ancillary Hispanic Community Health/Latinos Studies. Corrected %BF were regressed against 1/BMI in the parent study (n=15,261), fitting models for each age group, by sex and Hispanic/Latino background; predicted %BF was then computed for each BMI cut-point. Results BIA underestimated %BF by 8.7 ± 0.3% in women and 4.6 ± 0.3% in men (P < 0.0001). The %BF-BMI relationshp was non-linear and linear for 1/BMI. Sex- and age-specific regression parameters between %BF and 1/BMI were consistent across Hispanic/Latino backgrounds (P > 0.05). The precision of the %BF-1/BMI association weakened with increasing age in men but not women. The proportion of participants classified as non-obese by BMI but obese by %BF was generally higher among women and older adults (16.4% in women vs. 12.0% in men aged 50-74 y). Conclusions %BF was linearly related to 1/BMI with consistent relationship across Hispanic/Lation backgrounds. BMI cut-points consistently underestimated the proportion of Hispanics/Latinos with excess adiposity. PMID:27184359
Psychological and physiological correlates of childhood obesity in Taiwan
Chung, Kuo-Hsuan; Chiou, Hung-Yi; Chen, Yi-Hua
2015-01-01
Evidence of associations between psychopathology and obesity in childhood remains inconsistent, and most studies have been conducted in Western countries. This study investigated psychological and physiological correlates of obesity in a community sample of children in Taiwan. In total, 302 children (157 overweight/obese and 145 healthy-weight children) were selected from first- and fourth-grade schoolchildren in eight elementary schools in 2009. These children participated in a comprehensive health examination, including a physical examination, blood sample analysis, and questionnaire administration. We found that regarding physiological characteristics, compared with the healthy-weight children, the overweight/obese children had significantly higher values for body fat estimated using the bioelectrical impedance method (p < 0.001), systolic blood pressure (p < 0.001), and diastolic blood pressure (p = 0.001); lower values for high-density lipoprotein (p < 0.001); and worse values for glutamic-pyruvic transaminase (p < 0.001), triglycerides (p < 0.001), and fasting blood glucose (p = 0.049). In logistic models adjusted for parental and child traits and physiological characteristics, children’s overweight/obesity was significantly associated with lower self-concept (odds ratio [OR] = 0.96, 95% confidence interval [CI] = 0.93–0.99) and less disruptive behavior (OR = 0.96, 95% CI = 0.92–0.99). Less disruptive behavior and the lack of a higher prevalence of anxiety and depression in childhood obesity appear to be a unique pattern in Taiwan that warrants further investigation. PMID:26612264
Psychological and physiological correlates of childhood obesity in Taiwan.
Chung, Kuo-Hsuan; Chiou, Hung-Yi; Chen, Yi-Hua
2015-11-27
Evidence of associations between psychopathology and obesity in childhood remains inconsistent, and most studies have been conducted in Western countries. This study investigated psychological and physiological correlates of obesity in a community sample of children in Taiwan. In total, 302 children (157 overweight/obese and 145 healthy-weight children) were selected from first- and fourth-grade schoolchildren in eight elementary schools in 2009. These children participated in a comprehensive health examination, including a physical examination, blood sample analysis, and questionnaire administration. We found that regarding physiological characteristics, compared with the healthy-weight children, the overweight/obese children had significantly higher values for body fat estimated using the bioelectrical impedance method (p < 0.001), systolic blood pressure (p < 0.001), and diastolic blood pressure (p = 0.001); lower values for high-density lipoprotein (p < 0.001); and worse values for glutamic-pyruvic transaminase (p < 0.001), triglycerides (p < 0.001), and fasting blood glucose (p = 0.049). In logistic models adjusted for parental and child traits and physiological characteristics, children's overweight/obesity was significantly associated with lower self-concept (odds ratio [OR] = 0.96, 95% confidence interval [CI] = 0.93-0.99) and less disruptive behavior (OR = 0.96, 95% CI = 0.92-0.99). Less disruptive behavior and the lack of a higher prevalence of anxiety and depression in childhood obesity appear to be a unique pattern in Taiwan that warrants further investigation.
Cardiovascular program to improve physical fitness in those over 60 years old – pilot study
Castillo-Rodríguez, Alfonso; Chinchilla-Minguet, José Luis
2014-01-01
Background In Spain, more than 50% of 60-year-olds are obese. Obesity is a disease with serious cardiovascular risks. The mortality rate for cardiovascular disease in Spain is 31.1%. Objectives To improve aerobic fitness, strength, flexibility and balance, and body composition (BC) in persons over 60 years old. Materials and methods A clinical intervention study of 24 participants was carried out over a period of 3 months. Aerobic fitness was assessed using the Rockport 1-Mile Walk Test. Upper-body strength was evaluated with an ad hoc test. Flexibility and balance were evaluated using the Sit and Reach Test and the Stork Balance Stand Test, respectively. Anthropometric measurements were taken by bioelectrical impedance. Results After 3 months of training, aerobic fitness was improved, as demonstrated by improved test times (pretest 13.04 minutes, posttest 12.13 minutes; P<0.05). Body composition was also improved, but the results were not statistically significant (fat mass pretest 31.58%±5.65%, posttest 30.65%±6.31%; skeletal muscle mass pretest 43.99±9.53 kg, posttest 46.63±10.90 kg). Conclusion Our data show that in subjects over 60 years old, aerobic fitness was improved due to program intervention. However, these results should be treated with caution, because of the limited sample size and the brief time period of this pilot study. A more rigorous study would include a sample of at least 100 participants. PMID:25143714
Erdogan Iyigun, Zeynep; Selamoglu, Derya; Alco, Gul; Pilancı, Kezban Nur; Ordu, Cetin; Agacayak, Filiz; Elbüken, Filiz; Bozdogan, Atilla; Ilgun, Serkan; Guler Uysal, Fusun; Ozmen, Vahit
2015-03-01
The aim of this study was to evaluate the efficacy of bioimpedance spectroscopy for the follow-up of patients with lymphedema in Turkey and its benefits in the diagnosis of stage 0, 1, and 2 lymphedema in patients who are under treatment for breast cancer. Thirty-seven female patients with breast cancer who underwent surgical procedures in our Breast Health Centre were followed up for lymphedema using bioimpedance, and clinical measurements were taken for a minimum period of 1 year at 3-month intervals. Patients who had been monitored regularly between November, 2011, and September, 2013, were enrolled to the study. In total, 8 patients developed lymphedema with an overall rate of 21.6%. Among the 8 patients who developed lymphedema, 4 had Stage 2, 1 had Stage 1, and 3 had Stage 0 lymphedema. Stage 0 lymphedema could not be detected with clinical measurements. During the patients' 1-year follow-up period using measurements of bioimpedance, a statistically significant relationship was observed between the occurrence of lymphedema and the disease characteristics. including the number of the extracted and remaining lymph nodes and the region of radiotherapy (p=0.042, p=0.024, p=0.040). Bioimpedance analysis seems to be a practical and reliable method for the early diagnosis of lymphedema. It is believed that regular monitoring of patients in the high-risk group using bioimpedance analyses increases the ability to treat lymphedema.
Sarcopenia is associated with an increased risk of advanced colorectal neoplasia.
Park, Youn Su; Kim, Ji Won; Kim, Byeong Gwan; Lee, Kook Lae; Lee, Jae Kyung; Kim, Joo Sung; Koh, Seong-Joon
2017-04-01
Although sarcopenia is associated with an increased risk for mortality after the curative resection of colorectal cancer, its influence on the development of advanced colonic neoplasia remains unclear. This study included 1270 subjects aged 40 years or older evaluated with first-time screening colonoscopy at Seoul National University Boramae Health Care Center from January 2010 to February 2015. Skeletal muscle mass was measured with a body composition analyzer (direct segmental multifrequency bioelectrical impedance analysis method). Multiple logistic regression analysis was performed to determine whether sarcopenia is associated with advanced colorectal neoplasia. Of 1270 subjects, 139 (10.9%) were categorized into the sarcopenia group and 1131 (89.1%) into the non-sarcopenia group. In the non-sarcopenia group, 55 subjects (4.9%) had advanced colorectal neoplasia. However, in the sarcopenia group, 19 subjects (13.7%) had advanced colorectal neoplasia, including 1 subject with invasive colorectal cancer (0.7%). In addition, subjects with sarcopenia had a higher prevalence of advanced adenoma (P < 0.001) than those without sarcopenia. According to the multiple logistic regression analysis adjusted for variable confounders, age (odds ratio 1.062, 95% confidence interval 1.032-1.093; P < 0.001), male sex (odds ratio 1.749, 95% confidence interval 1.008-3.036; P = 0.047), and sarcopenia (odds ratio 2.347, 95% confidence interval 1.311-4.202; P = 0.004) were associated with an advanced colorectal neoplasia. Sarcopenia is associated with an increased risk of advanced colorectal neoplasia.
Dolfing, Jacoba G; Stassen, Chrit M; van Haard, Paul M M; Wolffenbuttel, Bruce H R; Schweitzer, Dave H
2011-06-01
BACKGROUND Polycystic ovary syndrome (PCOS) is a heterogeneous disorder. However, PCOS has a strong resemblance to the metabolic syndrome, including preponderance of visceral fat deposition. The aim of this study is to compare fat distribution between lean women with PCOS and controls matched for body composition but with regular menstrual cycles and proven fertility. METHODS In this prospective cross-sectional study in a fertility outpatient clinic, 10 Caucasian women with PCOS and 10 controls, all with a BMI between 19 and 25 kg/m(2), were included. Fasting glucose, insulin and C-peptide concentrations, homeostasis model assessment (HOMA), hormonal levels and bioelectrical impedance analysis (BIA) variables were assessed and fat content and ovarian volume determinations were obtained with magnetic resonance imaging (MRI). Multiple axial cross-sections were calculated. RESULTS The age of the PCOS and control groups were [mean (SD)] 28.2 years (2.6) versus 33.7 years (2.3) P < 0.0001, respectively, and both groups were matched for BMI: 21.6 kg/m(2) (1.1) versus 21.8 kg/m(2) (2.1) (ns), fasting glucose, insulin, C-peptide, HOMA-insulin resistance (IR) levels and BIA parameters. PCOS cases had higher ovarian volumes and less visceral fat compared with controls. CONCLUSIONS Lean women with PCOS have higher MRI-determined ovarian volumes and less visceral fat content when compared with control women.
Tracking of electrochemical impedance of batteries
NASA Astrophysics Data System (ADS)
Piret, H.; Granjon, P.; Guillet, N.; Cattin, V.
2016-04-01
This paper presents an evolutionary battery impedance estimation method, which can be easily embedded in vehicles or nomad devices. The proposed method not only allows an accurate frequency impedance estimation, but also a tracking of its temporal evolution contrary to classical electrochemical impedance spectroscopy methods. Taking into account constraints of cost and complexity, we propose to use the existing electronics of current control to perform a frequency evolutionary estimation of the electrochemical impedance. The developed method uses a simple wideband input signal, and relies on a recursive local average of Fourier transforms. The averaging is controlled by a single parameter, managing a trade-off between tracking and estimation performance. This normalized parameter allows to correctly adapt the behavior of the proposed estimator to the variations of the impedance. The advantage of the proposed method is twofold: the method is easy to embed into a simple electronic circuit, and the battery impedance estimator is evolutionary. The ability of the method to monitor the impedance over time is demonstrated on a simulator, and on a real Lithium ion battery, on which a repeatability study is carried out. The experiments reveal good tracking results, and estimation performance as accurate as the usual laboratory approaches.
NASA Technical Reports Server (NTRS)
White, C. W.
1981-01-01
The computational efficiency of the impedance type loads prediction method was studied. Three goals were addressed: devise a method to make the impedance method operate more efficiently in the computer; assess the accuracy and convenience of the method for determining the effect of design changes; and investigate the use of the method to identify design changes for reduction of payload loads. The method is suitable for calculation of dynamic response in either the frequency or time domain. It is concluded that: the choice of an orthogonal coordinate system will allow the impedance method to operate more efficiently in the computer; the approximate mode impedance technique is adequate for determining the effect of design changes, and is applicable for both statically determinate and statically indeterminate payload attachments; and beneficial design changes to reduce payload loads can be identified by the combined application of impedance techniques and energy distribution review techniques.
Sarma, Pranab Jyoti; Mohanty, Kaustubha
2018-04-13
In this study, two different unexploited indoor plants, Epipremnum aureum and Dracaena braunii were used to produce clean and sustainable bio-electricity in a plant microbial fuel cell (PMFC). Acid modified carbon fiber brush electrodes as well as bare electrodes were used in both the PMFCs. A bentonite based clay membrane was successfully integrated in the PMFCs. Maximum performance of E. aureum was 620 mV which was 188 mV higher potential than D. braunii. The bio-electricity generation using modified electrode was 154 mV higher than the bare carbon fiber, probably due to the effective bacterial attachment to the carbon fiber owing to hydrogen bonding. Maximum power output of 15.38 mW/m 2 was obtained by E. aureum with an internal resistance of 200 Ω. Higher biomass yield was also obtained in case of E. aureum during 60 days of experiment, which may correlate with the higher bio-electricity generation than D. braunii. Copyright © 2018 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Effect of electrical energy on the efficacy of biofilm treatment using the bioelectric effect
Kim, Young Wook; Subramanian, Sowmya; Gerasopoulos, Konstantinos; Ben-Yoav, Hadar; Wu, Hsuan-Chen; Quan, David; Carter, Karen; Meyer, Mariana T; Bentley, William E; Ghodssi, Reza
2015-01-01
Background/Objectives: The use of electric fields in combination with small doses of antibiotics for enhanced treatment of biofilms is termed the ‘bioelectric effect’ (BE). Different mechanisms of action for the AC and DC fields have been reported in the literature over the last two decades. In this work, we conduct the first study on the correlation between the electrical energy and the treatment efficacy of the bioelectric effect on Escherichia coli K-12 W3110 biofilms. Methods: A thorough study was performed through the application of alternating (AC), direct (DC) and superimposed (SP) potentials of different amplitudes on mature E. coli biofilms. The electric fields were applied in combination with the antibiotic gentamicin (10 μg/ml) over a course of 24 h, after the biofilms had matured for 24 h. The biofilms were analysed using the crystal violet assay, the colony-forming unit method and fluorescence microscopy. Results: Results show that there is no statistical difference in treatment efficacy between the DC-, AC- and SP-based BE treatment of equivalent energies (analysis of variance (ANOVA) P>0.05) for voltages <1 V. We also demonstrate that the efficacy of the BE treatment as measured by the crystal violet staining method and colony-forming unit assay is proportional to the electrical energy applied (ANOVA P<0.05). We further verify that the treatment efficacy varies linearly with the energy of the BE treatment (r2 =0.984). Our results thus suggest that the energy of the electrical signal is the primary factor in determining the efficacy of the BE treatment, at potentials less than the media electrolysis voltage. Conclusions: Our results demonstrate that the energy of the electrical signal, and not the type of electrical signal (AC or DC or SP), is the key to determine the efficacy of the BE treatment. We anticipate that this observation will pave the way for further understanding of the mechanism of action of the BE treatment method and may open new doors to the use of electric fields in the treatment of bacterial biofilms. PMID:28721233
Valencia, M E; Alemán-Mateo, H; Salazar, G; Hernández Triana, M
2003-07-01
In Latin American and Caribbean countries such as Chile, Mexico and Cuba, the population over 60 y has increased steadily. In this age group, there is scarce information about body composition, particularly for those living in rural areas. The purpose of this study was to determine body composition in free-living and healthy elderly subjects >60 y from rural areas of Chile, Cuba and Mexico using deuterium oxide dilution and bioelectrical impedance (BIA) and to develop and cross-validate a predictive equation for this group of subjects by BIA for future use as a field technique. The study included 133 healthy subjects (73 males and 60 females) >60 y from rural regions of Cuba, Chile and Mexico. Total body water, body weight, height and other anthropometric and BIA variables (resistance and reactance) were measured. Total body water was determined by deuterium oxide dilution, and fat-free mass (FFM)/fat mass were derived from this measurement. The total sample was used in a split-sample internal cross-validation. BIA and other anthropometric variables were integrated to multiple regression model to design the best predictive equation, which was validated in the other sample. ANOVA, multiple regression and Bland and Altman's procedure were used to analyze the data. Body weight, percentage of fat and fat-free mass were lower in the Cuban men and women compared with Chilean and Mexican men and women. The best predictive equation of the FFM was: FFM kg=(-7.71+(H(2)/R x 0.49)+(country or ethnicity x 1.12)+(body weight x 0.27)+(sex x 3.49)+(Xc x 0.13)), where H(2) is height(2) (cm); R is resistance (Omega); country: Chile=1, Mexico=2 and Cuba=3; sex: women=0 and men=1; body weight (kg) and Xc is reactance (Omega). R(2) was 0.944 and the root mean square error (RMSE) was 2.08 kg. The mean+/-s.d. of FFM prediction was 44.2+/-9.2 vs 44.6+/-10.1. The results of cross-validation showed no significant difference with the line of identity, showing that the predicted equation was accurate. The intercept (=-0.32) was not significantly different from zero (P=0.89) and the slope (=1.02) not significantly different from 1.0 (P>0.9). The R(2) was 0.86, RMSE=3.86 kg of FFM and the pure error was 3.83. The new BIA equation is accurate, precise and showed good agreement. The use of this equation could improve the estimates of body composition for the elderly population for these regions, as well as enhancing the opportunity to conduct studies in the elderly population from Latin America.
Method to tune electrical impedance of LSMO/PMN-PT by nanocontact
NASA Astrophysics Data System (ADS)
Zhou, Hao; Pei, Yongmao; Wang, Yaobing; Lei, Hongshuai
2018-01-01
Electromagnetic composites have wide application in the functional devices. For the best performance of devices, the regulation of the electrical impedance has been being desired for the impedance matching in service. However, the keeping of impedance matching in service is quite challenging. In the present work, a mechanical method for tuning the electrical impedance of La0.7Sr0.3MnO3/0.72Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 (LSMO/PMN-PT) based on the nanocontact technique is proposed. It is found that the electrical impedance reduces with the increase of the nanocontact load. A linear relationship is found between the square of impedance magnitude and the inverse of nanocontact depth. Furthermore, a method for predicting the contact-depth-dependent impedance magnitude of LSMO/PMN-PT is proposed.
Barkar, A A; Markina, L D
2014-01-01
In the article there is considered the relationship between adaptation state of the organism and features of bioelectric activity of the brain in right-handers and left-handers. Practically healthy persons of both genders, 23-45 years of age, with the chronic stress disorder were examined. Adaptation status was evaluated with a computer software "Anti-stress", features of bioelectric brain activity were detected by means of spectral and coherent EEG analysis, also the character of motor and sensory asymmetries was determined. The obtained data showed that the response of the organism to excitators of varying strength is a system one and manifested at different levels; adaptation status and bioelectrical activity in right-handers and left-handers have features.
Bioelectric Signal Measuring System
NASA Astrophysics Data System (ADS)
Guadarrama-Santana, A.; Pólo-Parada, L.; García-Valenzuela, A.
2015-01-01
We describe a low noise measuring system based on interdigitated electrodes for sensing bioelectrical signals. The system registers differential voltage measurements in order of microvolts. The base noise during measurements was in nanovolts and thus, the sensing signals presented a very good signal to noise ratio. An excitation voltage of 1Vrms with 10 KHz frequency was applied to an interdigitated capacitive sensor without a material under test and to a mirror device simultaneously. The output signals of both devices was then subtracted in order to obtain an initial reference value near cero volts and reduce parasitic capacitances due to the electronics, wiring and system hardware as well. The response of the measuring system was characterized by monitoring temporal bioelectrical signals in real time of biological materials such as embryo chicken heart cells and bovine suprarenal gland cells.
Son, Jeong-Hyun; Park, Gi Duck; Park, Hoo Sung
2014-06-01
[Purpose] The present study aimed to determine the effect of an 8-week program of joint mobilization on changes in pelvic obliquity and pain level in seventeen female university students aged in their 20's with sacroiliac joint dysfunction by dividing them into two groups: a joint mobilization group (MWM) and a control group. [Subjects] Seventeen subjects were selected from female university students aged in their 20's attending N University in Cheon-An City, Korea, The subjects had sacroiliac joint syndrome, but experienced no problems with daily living and had no previous experience of joint mobilization exercise. The subjects were randomly assigned to a joint mobilization group of eight and a control group of nine who performed joint mobilization exercise. [Methods] Body fat and lean body mass were measured using InBody 7.0 (Biospace, Korea). The Direct Segmental Multi-frequency Bioelectrical Impedance Analysis Method (DSM-BIA) was used for body composition measurement. A pressure footstool (Pedoscan, DIERS, Germany) and a trunk measurement system (Formetric 4D, DIERS, Germany), a 3D image processing apparatus with high resolution for vertebrae, were used to measure 3D trunk images of the vertebrae and pelvis obliquity, as well as static balance ability. [Result] The MWM group showed a significantly better Balance than the control group. In addition, the results of the left/right and the front/rear balance abilities were significantly better than those of the control group. [Conclusion] This study proved that a combination of mobilization with movement and functional training was effective in reducing pelvis malposition and pain, and improving static stability control.
Kerr, Ava; Slater, Gary J; Byrne, Nuala
2017-02-01
Two, three and four compartment (2C, 3C and 4C) models of body composition are popular methods to measure fat mass (FM) and fat-free mass (FFM) in athletes. However, the impact of food and fluid intake on measurement error has not been established. The purpose of this study was to evaluate standardised (overnight fasted, rested and hydrated) v. non-standardised (afternoon and non-fasted) presentation on technical and biological error on surface anthropometry (SA), 2C, 3C and 4C models. In thirty-two athletic males, measures of SA, dual-energy X-ray absorptiometry (DXA), bioelectrical impedance spectroscopy (BIS) and air displacement plethysmography (BOD POD) were taken to establish 2C, 3C and 4C models. Tests were conducted after an overnight fast (duplicate), about 7 h later after ad libitum food and fluid intake, and repeated 24 h later before and after ingestion of a specified meal. Magnitudes of changes in the mean and typical errors of measurement were determined. Mean change scores for non-standardised presentation and post meal tests for FM were substantially large in BIS, SA, 3C and 4C models. For FFM, mean change scores for non-standardised conditions produced large changes for BIS, 3C and 4C models, small for DXA, trivial for BOD POD and SA. Models that included a total body water (TBW) value from BIS (3C and 4C) were more sensitive to TBW changes in non-standardised conditions than 2C models. Biological error is minimised in all models with standardised presentation but DXA and BOD POD are acceptable if acute food and fluid intake remains below 500 g.
Clinical anthropometrics and body composition from 3D whole-body surface scans.
Ng, B K; Hinton, B J; Fan, B; Kanaya, A M; Shepherd, J A
2016-11-01
Obesity is a significant worldwide epidemic that necessitates accessible tools for robust body composition analysis. We investigated whether widely available 3D body surface scanners can provide clinically relevant direct anthropometrics (circumferences, areas and volumes) and body composition estimates (regional fat/lean masses). Thirty-nine healthy adults stratified by age, sex and body mass index (BMI) underwent whole-body 3D scans, dual energy X-ray absorptiometry (DXA), air displacement plethysmography and tape measurements. Linear regressions were performed to assess agreement between 3D measurements and criterion methods. Linear models were derived to predict DXA body composition from 3D scan measurements. Thirty-seven external fitness center users underwent 3D scans and bioelectrical impedance analysis for model validation. 3D body scan measurements correlated strongly to criterion methods: waist circumference R 2 =0.95, hip circumference R 2 =0.92, surface area R 2 =0.97 and volume R 2 =0.99. However, systematic differences were observed for each measure due to discrepancies in landmark positioning. Predictive body composition equations showed strong agreement for whole body (fat mass R 2 =0.95, root mean square error (RMSE)=2.4 kg; fat-free mass R 2 =0.96, RMSE=2.2 kg) and arms, legs and trunk (R 2 =0.79-0.94, RMSE=0.5-1.7 kg). Visceral fat prediction showed moderate agreement (R 2 =0.75, RMSE=0.11 kg). 3D surface scanners offer precise and stable automated measurements of body shape and composition. Software updates may be needed to resolve measurement biases resulting from landmark positioning discrepancies. Further studies are justified to elucidate relationships between body shape, composition and metabolic health across sex, age, BMI and ethnicity groups, as well as in those with metabolic disorders.
Gieβsing, Jùrgen; Fisher, James; Steele, James; Rothe, Frank; Raubold, Kristin; Eichmann, Björn
2016-03-01
This study examined low-volume resistance training (RT) in trained participants with and without advanced training methods. Trained participants (RT experience 4±3 years) were randomised to groups performing single-set RT: ssRM (N.=21) performing repetitions to self-determined repetition maximum (RM), ssMMF (N.=30) performing repetitions to momentary muscular failure (MMF), and ssRP (N.=28) performing repetitions to self-determined RM using a rest pause (RP) method. Each performed supervised RT twice/week for 10 weeks. Outcomes included maximal isometric strength and body composition using bioelectrical impedance analysis. The ssRM group did not significantly improve in any outcome. The ssMMF and ssRP groups both significantly improved strength (p < 0.05). Magnitude of changes using effect size (ES) was examined between groups. Strength ES's were considered large for ssMMF (0.91 to 1.57) and ranging small to large for ssRP (0.42 to 1.06). Body composition data revealed significant improvements (P<0.05) in muscle and fat mass and percentages for whole body, upper limbs and trunk for ssMMF, but only upper limbs for ssRP. Body composition ES's ranged moderate to large for ssMMF (0.56 to 1.27) and ranged small to moderate for ssRP (0.28 to 0.52). ssMMF also significantly improved (P<0.05) total abdominal fat and increased intracellular water with moderate ES's (-0.62 and 0.56, respectively). Training to self-determined RM is not efficacious for trained participants. Training to MMF produces greatest improvements in strength and body composition, however, RP style training does offer some benefit.
Moon, J R
2013-01-01
The purpose of the current review was to evaluate how body composition can be utilised in athletes, paying particular attention to the bioelectrical impedance analysis (BIA) technique. Various body composition methods are discussed, as well as the unique characteristics of athletes that can lead to large errors when predicting fat mass (FM) and fat-free mass (FFM). Basic principles of BIA are discussed, and past uses of the BIA technique in athletes are explored. Single-prediction validation studies and studies tracking changes in FM and FFM are discussed with applications for athletes. Although extensive research in the area of BIA and athletes has been conducted, there remains a large gap in the literature pertaining to a single generalised athlete equation developed using a multiple-compartment model that includes total body water (TBW). Until a generalised athlete-specific BIA equation developed from a multiple-compartment is published, it is recommended that generalised equations such as those published by Lukaski and Bolonchuk and Lohman be used in athletes. However, BIA equations developed for specific athletes may also produce acceptable values and are still acceptable for use until more research is conducted. The use of a valid BIA equation/device should produce values similar to those of hydrostatic weighing and dual-energy X-ray absorptiometry. However, researchers and practitioners need to understand the individual variability associated with BIA estimations for both single assessments and repeated measurements. Although the BIA method shows promise for estimating body composition in athletes, future research should focus on the development of general athlete-specific equations using a TBW-based three- or four-compartment model.
New diagnostic index for sarcopenia in patients with cardiovascular diseases
Kai, Hisashi; Shibata, Rei; Niiyama, Hiroshi; Nishiyama, Yasuhiro; Murohara, Toyoaki; Yoshida, Noriko; Katoh, Atsushi; Ikeda, Hisao
2017-01-01
Background Sarcopenia is an aging and disease-related syndrome characterized by progressive and generalized loss of skeletal muscle mass and strength, with the risk of frailty and poor quality of life. Sarcopenia is diagnosed by a decrease in skeletal muscle index (SMI) and reduction of either handgrip strength or gait speed. However, measurement of SMI is difficult for general physicians because it requires special equipment for bioelectrical impedance assay or dual-energy X-ray absorptiometry. The purpose of this study was, therefore, to explore a novel, simple diagnostic method of sarcopenia evaluation in patients with cardiovascular diseases (CVD). Methods We retrospectively investigated 132 inpatients with CVD (age: 72±12 years, age range: 27–93 years, males: 61%) Binomial logistic regression and correlation analyses were used to assess the associations of sarcopenia with simple physical data and biomarkers, including muscle-related inflammation makers and nutritional markers. Results Sarcopenia was present in 29.5% of the study population. Serum concentrations of adiponectin and sialic acid were significantly higher in sarcopenic than non-sarcopenic CVD patients. Stepwise multivariate binomial logistic regression analysis revealed that adiponectin, sialic acid, sex, age, and body mass index were independent factors for sarcopenia detection. Sarcopenia index, obtained from the diagnostic regression formula for sarcopenia detection including the five independent factors, indicated a high accuracy in ROC curve analysis (sensitivity 94.9%, specificity 69.9%) and the cutoff value for sarcopenia detection was -1.6134. Sarcopenia index had a significant correlation with the conventional diagnostic parameters of sarcopenia. Conclusions Our new sarcopenia index using simple parameters would be useful for diagnosing sarcopenia in CVD patients. PMID:28542531
A Numerical Theory for Impedance Education in Three-Dimensional Normal Incidence Tubes
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.
2016-01-01
A method for educing the locally-reacting acoustic impedance of a test sample mounted in a 3-D normal incidence impedance tube is presented and validated. The unique feature of the method is that the excitation frequency (or duct geometry) may be such that high-order duct modes may exist. The method educes the impedance, iteratively, by minimizing an objective function consisting of the difference between the measured and numerically computed acoustic pressure at preselected measurement points in the duct. The method is validated on planar and high-order mode sources with data synthesized from exact mode theory. These data are then subjected to random jitter to simulate the effects of measurement uncertainties on the educed impedance spectrum. The primary conclusions of the study are 1) Without random jitter the method is in excellent agreement with that for known impedance samples, and 2) Random jitter that is compatible to that found in a typical experiment has minimal impact on the accuracy of the educed impedance.
Implementation and Validation of an Impedance Eduction Technique
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.; Gerhold, Carl H.
2011-01-01
Implementation of a pressure gradient method of impedance eduction in two NASA Langley flow ducts is described. The Grazing Flow Impedance Tube only supports plane-wave sources, while the Curved Duct Test Rig supports sources that contain higher-order modes. Multiple exercises are used to validate this new impedance eduction method. First, synthesized data for a hard wall insert and a conventional liner mounted in the Grazing Flow Impedance Tube are used as input to the two impedance eduction methods, the pressure gradient method and a previously validated wall pressure method. Comparisons between the two results are excellent. Next, data measured in the Grazing Flow Impedance Tube are used as input to both methods. Results from the two methods compare quite favorably for sufficiently low Mach numbers but this comparison degrades at Mach 0.5, especially when the hard wall insert is used. Finally, data measured with a hard wall insert mounted in the Curved Duct Test Rig are used as input to the pressure gradient method. Significant deviation from the known solution is observed, which is believed to be largely due to 3-D effects in this flow duct. Potential solutions to this issue are currently being explored.
Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Tordecilla-Sanders, Alejandra; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline; González-Jiménez, Emilio
2017-09-21
The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson's correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample t -test, Lin's concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was r = 0.885, p < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin's concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (-5.6 (95%CI -6.4 to -4.8); p < 0.001). In the women, these differences were (-3.6 (95%CI -4.7 to -2.5); p < 0.001). Overall, the bias of the BAI-BF% was -4.8 ± 3.2 BF%; p < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups.
González-Ruíz, Katherine; Schmidt-RioValle, Jacqueline
2017-01-01
The aim of this study is to investigate the accuracy of body adiposity index (BAI) as a convenient tool for assessing body fat percentage (BF%) in a sample of adults with overweight/obesity using bioelectrical impedance analysis (BIA). The study population was composed of 96 volunteers (60% female, mean age 40.6 ± 7.5 years old). Anthropometric characteristics (body mass index, height, waist-to-height ratio, hip and waist circumference), socioeconomic status, and diet were assessed, and BF% was measured by BIA-BF% and by BAI-BF%. Pearson’s correlation coefficient was used to evaluate the correlation between BAI-BF% and BF% assessed by BIA-BF%, while controlling for potential confounders. The concordance between the BF% measured by both methods was obtained with a paired sample t-test, Lin’s concordance correlation coefficient, and Bland-Altman plot analysis. Overall, the correlation between BF% obtained by BIA-BF% and estimated by BAI-BF% was r = 0.885, p < 0.001, after adjusting for potential confounders (age, socioeconomic status, and diet). Lin’s concordance correlation coefficient was moderate in both sexes. In the men, the paired t-test showed a significant mean difference in BF% between the methods (−5.6 (95% CI −6.4 to −4.8); p < 0.001). In the women, these differences were (−3.6 (95% CI −4.7 to −2.5); p < 0.001). Overall, the bias of the BAI-BF% was −4.8 ± 3.2 BF%; p < 0.001), indicating that the BAI-BF% method significantly underestimated the BF% in comparison with the reference method. In adults with overweight/obesity, the BAI presents low agreement with BF% measured by BIA-BF%; therefore, we conclude that BIA-BF% is not accurate in either sex when body fat percentage levels are low or high. Further studies are necessary to confirm our findings in different ethnic groups. PMID:28934175
Personnel Detection Technology Assessment Final Report
2003-04-16
3.1.2.1 Bioelectric Activity Nerve impulses generate very weak bioelectric signals that can be detected by external probes at short ranges. The...covert detection /tracking scenarios. It was concluded that, in general , distributed sensor networks will be required to meet the scenario...personnel detection was recognized by the US Army Research Office (ARO). The Ohio State University was tasked to assess the status of sensors and signal
NASA Astrophysics Data System (ADS)
Yu, Zhang; Xiaohui, Song; Jianfang, Li; Fei, Gao
2017-05-01
Cable overheating will lead to the cable insulation level reducing, speed up the cable insulation aging, even easy to cause short circuit faults. Cable overheating risk identification and warning is nessesary for distribution network operators. Cable overheating risk warning method based on impedance parameter estimation is proposed in the paper to improve the safty and reliability operation of distribution network. Firstly, cable impedance estimation model is established by using least square method based on the data from distribiton SCADA system to improve the impedance parameter estimation accuracy. Secondly, calculate the threshold value of cable impedance based on the historical data and the forecast value of cable impedance based on the forecasting data in future from distribiton SCADA system. Thirdly, establish risks warning rules library of cable overheating, calculate the cable impedance forecast value and analysis the change rate of impedance, and then warn the overheating risk of cable line based on the overheating risk warning rules library according to the variation relationship between impedance and line temperature rise. Overheating risk warning method is simulated in the paper. The simulation results shows that the method can identify the imedance and forecast the temperature rise of cable line in distribution network accurately. The result of overheating risk warning can provide decision basis for operation maintenance and repair.
A Fast Framework for Abrupt Change Detection Based on Binary Search Trees and Kolmogorov Statistic
Qi, Jin-Peng; Qi, Jie; Zhang, Qing
2016-01-01
Change-Point (CP) detection has attracted considerable attention in the fields of data mining and statistics; it is very meaningful to discuss how to quickly and efficiently detect abrupt change from large-scale bioelectric signals. Currently, most of the existing methods, like Kolmogorov-Smirnov (KS) statistic and so forth, are time-consuming, especially for large-scale datasets. In this paper, we propose a fast framework for abrupt change detection based on binary search trees (BSTs) and a modified KS statistic, named BSTKS (binary search trees and Kolmogorov statistic). In this method, first, two binary search trees, termed as BSTcA and BSTcD, are constructed by multilevel Haar Wavelet Transform (HWT); second, three search criteria are introduced in terms of the statistic and variance fluctuations in the diagnosed time series; last, an optimal search path is detected from the root to leaf nodes of two BSTs. The studies on both the synthetic time series samples and the real electroencephalograph (EEG) recordings indicate that the proposed BSTKS can detect abrupt change more quickly and efficiently than KS, t-statistic (t), and Singular-Spectrum Analyses (SSA) methods, with the shortest computation time, the highest hit rate, the smallest error, and the highest accuracy out of four methods. This study suggests that the proposed BSTKS is very helpful for useful information inspection on all kinds of bioelectric time series signals. PMID:27413364
A Fast Framework for Abrupt Change Detection Based on Binary Search Trees and Kolmogorov Statistic.
Qi, Jin-Peng; Qi, Jie; Zhang, Qing
2016-01-01
Change-Point (CP) detection has attracted considerable attention in the fields of data mining and statistics; it is very meaningful to discuss how to quickly and efficiently detect abrupt change from large-scale bioelectric signals. Currently, most of the existing methods, like Kolmogorov-Smirnov (KS) statistic and so forth, are time-consuming, especially for large-scale datasets. In this paper, we propose a fast framework for abrupt change detection based on binary search trees (BSTs) and a modified KS statistic, named BSTKS (binary search trees and Kolmogorov statistic). In this method, first, two binary search trees, termed as BSTcA and BSTcD, are constructed by multilevel Haar Wavelet Transform (HWT); second, three search criteria are introduced in terms of the statistic and variance fluctuations in the diagnosed time series; last, an optimal search path is detected from the root to leaf nodes of two BSTs. The studies on both the synthetic time series samples and the real electroencephalograph (EEG) recordings indicate that the proposed BSTKS can detect abrupt change more quickly and efficiently than KS, t-statistic (t), and Singular-Spectrum Analyses (SSA) methods, with the shortest computation time, the highest hit rate, the smallest error, and the highest accuracy out of four methods. This study suggests that the proposed BSTKS is very helpful for useful information inspection on all kinds of bioelectric time series signals.
Andrade, N J; Bridgeman, T A; Zottola, E A
1998-07-01
Enterococcus faecium attached to stainless steel chips (100 mm2) was treated with the following sanitizers: sodium hypochlorite, peracetic acid (PA), peracetic acid plus an organic acid (PAS), quaternary ammonium, organic acid, and anionic acid. The effectiveness of sanitizer solutions on planktonic cells (not attached) was evaluated by the Association of Official Analytical Chemists (AOAC) suspension test. The number of attached cells was determined by impedance measurement and plate count method after vortexing. The decimal reduction (DR) in numbers of the E. faecium population was determined for the three methods and was analyzed by analysis of variance (P < 0.05) using Statview software. The adhered cells were more resistant (P < 0.05) than nonadherent cells. The DR averages for all of the sanitizers for 30 s of exposure were 6.4, 2.2, and 2.5 for the AOAC suspension test, plate count method after vortexing, and impedance measurement, respectively. Plate count and impedance methods showed a difference (P < 0.05) after 30 s of sanitizer exposure but not after 2 min. The impedance measurement was the best method to measure adherent cells. Impedance measurement required the development of a quadratic regression. The equation developed from 82 samples is as follows: log CFU/chip = 0.2385T2-0.96T + 9.35, r2 = 0.92, P < 0.05, T = impedance detection time in hours. This method showed that the sanitizers PAS and PA were more effective against E. faecium than the other sanitizers. At 30 s, the impedance method recovered about 25 times more cells than the plate count method after vortexing. These data suggest that impedance measurement is the method of choice when evaluating the number of bacterial cells adhered to a surface.
Comparison of Two Acoustic Waveguide Methods for Determining Liner Impedance
NASA Technical Reports Server (NTRS)
Jones, Michael G.; Watson, Willie R.; Tracy, Maureen B.; Parrott, Tony L.
2001-01-01
Acoustic measurements taken in a flow impedance tube are used to assess the relative accuracy of two waveguide methods for impedance eduction in the presence of grazing flow. The aeroacoustic environment is assumed to contain forward and backward-traveling acoustic waves, consisting of multiple modes, and uniform mean flow. Both methods require a measurement of the complex acoustic pressure profile over the length of the test liner. The Single Mode Method assumes that the sound pressure level and phase decay-rates of a single progressive mode can be extracted from this measured complex acoustic pressure profile. No a priori assumptions are made in the Finite Element. Method regarding the modal or reflection content in the measured acoustic pressure profile. The integrity of each method is initially demonstrated by how well their no-flow impedances match those acquired in a normal incidence impedance tube. These tests were conducted using ceramic tubular and conventional perforate liners. Ceramic tubular liners were included because of their impedance insensitivity to mean flow effects. Conversely, the conventional perforate liner was included because its impedance is known to be sensitive to mean flow velocity effects. Excellent comparisons between impedance values educed with the two waveguide methods in the absence of mean flow and the corresponding values educed with the normal incident impedance tube were observed. The two methods are then compared for mean flow Mach numbers up to 0.5, and are shown to give consistent results for both types of test liners. The quality of the results indicates that the Single Mode Method should be used when the measured acoustic pressure profile is clearly dominated by a single progressive mode, and the Finite Element Method should be used for all other cases.
Comparison of multiple methods to measure maternal fat mass in late gestation12
Marshall, Nicole E; Murphy, Elizabeth J; King, Janet C; Haas, E Kate; Lim, Jeong Y; Wiedrick, Jack; Thornburg, Kent L; Purnell, Jonathan Q
2016-01-01
Background: Measurements of maternal fat mass (FM) are important for studies of maternal and fetal health. Common methods of estimating FM have not been previously compared in pregnancy with measurements using more complete body composition models. Objectives: The goal of this pilot study was to compare multiple methods that estimate FM, including 2-, 3- and 4-compartment models in pregnant women at term, and to determine how these measures compare with FM by dual-energy X-ray absorptiometry (DXA) 2 wk postpartum. Design: Forty-one healthy pregnant women with prepregnancy body mass index (in kg/m2) 19 to 46 underwent skinfold thickness (SFT), bioelectrical impedance analysis (BIA), body density (Db) via air displacement plethysmography (ADP), and deuterium dilution of total body water (TBW) with and without adjustments for gestational age using van Raaij (VRJ) equations at 37–38 wk of gestation and 2 wk postpartum to derive 8 estimates of maternal FM. Deming regression analysis and Bland-Altman plots were used to compare methods of FM assessment. Results: Systematic differences in FM estimates were found. Methods for FM estimates from lowest to highest were 4-compartment, DXA, TBW(VRJ), 3-compartment, Db(VRJ), BIA, air displacement plethysmography body density, and SFT ranging from a mean ± SD of 29.5 ± 13.2 kg via 4-compartment to 39.1 ± 11.7 kg via SFT. Compared with postpartum DXA values, Deming regressions revealed no substantial departures from trend lines in maternal FM in late pregnancy for any of the methods. The 4-compartment method showed substantial negative (underestimating) constant bias, and the air displacement plethysmography body density and SFT methods showed positive (overestimating) constant bias. ADP via Db(VRJ) and 3-compartment methods had the highest precision; BIA had the lowest. Conclusions: ADP that uses gestational age-specific equations may provide a reasonable and practical measurement of maternal FM across a spectrum of body weights in late pregnancy. SFT would be acceptable for use in larger studies. This trial was registered at clinicaltrials.gov as NCT02586714. PMID:26888714
Glenn, David F.; Matthern, Gretchen E.; Propp, W. Alan; Glenn, Anne W.; Shaw, Peter G.
2006-08-08
A method and apparatus for determining spatial locations of defects in a material are described. The method includes providing a plurality of electrodes in contact with a material, applying a sinusoidal voltage to a select number of the electrodes at a predetermined frequency, determining gain and phase angle measurements at other of the electrodes in response to applying the sinusoidal voltage to the select number of electrodes, determining impedance values from the gain and phase angle measurements, computing an impedance spectrum for an area of the material from the determined impedance values, and comparing the computed impedance spectrum with a known impedance spectrum to identify spatial locations of defects in the material.
Impedance measurement using a two-microphone, random-excitation method
NASA Technical Reports Server (NTRS)
Seybert, A. F.; Parrott, T. L.
1978-01-01
The feasibility of using a two-microphone, random-excitation technique for the measurement of acoustic impedance was studied. Equations were developed, including the effect of mean flow, which show that acoustic impedance is related to the pressure ratio and phase difference between two points in a duct carrying plane waves only. The impedances of a honeycomb ceramic specimen and a Helmholtz resonator were measured and compared with impedances obtained using the conventional standing-wave method. Agreement between the two methods was generally good. A sensitivity analysis was performed to pinpoint possible error sources and recommendations were made for future study. The two-microphone approach evaluated in this study appears to have some advantages over other impedance measuring techniques.
Imaging electric field dynamics with graphene optoelectronics
Horng, Jason; Balch, Halleh B.; McGuire, Allister F.; ...
2016-12-16
The use of electric fields for signalling and control in liquids is widespread, spanning bioelectric activity in cells to electrical manipulation of microstructures in lab-on-a-chip devices. However, an appropriate tool to resolve the spatio-temporal distribution of electric fields over a large dynamic range has yet to be developed. Here we present a label-free method to image local electric fields in real time and under ambient conditions. Our technique combines the unique gate-variable optical transitions of graphene with a critically coupled planar waveguide platform that enables highly sensitive detection of local electric fields with a voltage sensitivity of a few microvolts,more » a spatial resolution of tens of micrometres and a frequency response over tens of kilohertz. Our imaging platform enables parallel detection of electric fields over a large field of view and can be tailored to broad applications spanning lab-on-a-chip device engineering to analysis of bioelectric phenomena.« less
Imaging electric field dynamics with graphene optoelectronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horng, Jason; Balch, Halleh B.; McGuire, Allister F.
The use of electric fields for signalling and control in liquids is widespread, spanning bioelectric activity in cells to electrical manipulation of microstructures in lab-on-a-chip devices. However, an appropriate tool to resolve the spatio-temporal distribution of electric fields over a large dynamic range has yet to be developed. Here we present a label-free method to image local electric fields in real time and under ambient conditions. Our technique combines the unique gate-variable optical transitions of graphene with a critically coupled planar waveguide platform that enables highly sensitive detection of local electric fields with a voltage sensitivity of a few microvolts,more » a spatial resolution of tens of micrometres and a frequency response over tens of kilohertz. Our imaging platform enables parallel detection of electric fields over a large field of view and can be tailored to broad applications spanning lab-on-a-chip device engineering to analysis of bioelectric phenomena.« less
Treating a pressure ulcer with bio-electric stimulation therapy.
Hampton, Sylvie; Collins, Fiona
Mr Jones lived independently until he developed necrotic pressure ulcers over his heels and could no longer mobilize to care for himself. He was transferred to a nursing home where he lived for 18 months and where the nurses could care for his wounds. The wound had been on his right heel without changing over the 18 months and, although attempts to hydrate the eschar had been somewhat successful, the necrotic tissue proved stubborn creating large quantity of fibrous slough. Mr Jones was initially assessed by the tissue viability consultant on 14 March 2005 and agreed to the application of bio-electric stimulation therapy (POSiFEC). The wound change was immediate and was fully healed by 16 June 2005, 12 weeks after his initial assessment. This article outlines his care and the background to bio-electrical stimulation in wounds.
Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation.
Cao, Hong; Tungjitkusolmun, Supan; Choy, Young Bin; Tsai, Jang-Zern; Vorperian, Vicken R; Webster, John G
2002-03-01
During radio-frequency (RF) cardiac catheter ablation, there is little information to estimate the contact between the catheter tip electrode and endocardium because only the metal electrode shows up under fluoroscopy. We present a method that utilizes the electrical impedance between the catheter electrode and the dispersive electrode to predict the catheter tip electrode insertion depth into the endocardium. Since the resistivity of blood differs from the resistivity of the endocardium, the impedance increases as the catheter tip lodges deeper in the endocardium. In vitro measurements yielded the impedance-depth relations at 1, 10, 100, and 500 kHz. We predict the depth by spline curve interpolation using the obtained calibration curve. This impedance method gives reasonably accurate predicted depth. We also evaluated alternative methods, such as impedance difference and impedance ratio.
An equivalent body surface charge model representing three-dimensional bioelectrical activity
NASA Technical Reports Server (NTRS)
He, B.; Chernyak, Y. B.; Cohen, R. J.
1995-01-01
A new surface-source model has been developed to account for the bioelectrical potential on the body surface. A single-layer surface-charge model on the body surface has been developed to equivalently represent bioelectrical sources inside the body. The boundary conditions on the body surface are discussed in relation to the surface-charge in a half-space conductive medium. The equivalent body surface-charge is shown to be proportional to the normal component of the electric field on the body surface just outside the body. The spatial resolution of the equivalent surface-charge distribution appears intermediate between those of the body surface potential distribution and the body surface Laplacian distribution. An analytic relationship between the equivalent surface-charge and the surface Laplacian of the potential was found for a half-space conductive medium. The effects of finite spatial sampling and noise on the reconstruction of the equivalent surface-charge were evaluated by computer simulations. It was found through computer simulations that the reconstruction of the equivalent body surface-charge from the body surface Laplacian distribution is very stable against noise and finite spatial sampling. The present results suggest that the equivalent body surface-charge model may provide an additional insight to our understanding of bioelectric phenomena.
NASA Astrophysics Data System (ADS)
Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.
2015-01-01
The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.
Ezeh, Uche; Pall, Marita; Mathur, Ruchi; Azziz, Ricardo
2014-01-01
STUDY QUESTION Are differences in metabolic dysfunction between polycystic ovary syndrome (PCOS) and control women related to differences in their fat to lean mass (F/L) ratio? SUMMARY ANSWER Compared with controls of similar body mass index (BMI), women with PCOS demonstrate adverse body composition characterized by increased whole body fat relative to lean mass (i.e. a higher F/L ratio), which is associated with differences in metabolic dysfunction between the two groups. WHAT IS KNOWN ALREADY Previous studies examining body composition and insulin resistance (IR) in PCOS have yielded conflicting results. Excess total fat mass (i.e. fat mass index [fat BMI]) correlates with IR, whereas increased total lean mass (i.e. lean BMI) has been associated with higher insulin sensitivity. However, the role of the F/L ratio, which integrates the antagonistic effects of both fat and lean mass depots, on IR in PCOS, has not been investigated. STUDY DESIGN, SIZE, DURATION We conducted a prospective cross-sectional study of 120 women between the ages of 22–44 years to study the relation of the F/L ratio with measures of insulin action and secretion in both steady and dynamic states. PARTICIPANTS/MATERIALS, SETTING, METHODS Sixty PCOS (by NIH, 1990 criteria) and 60 control (age, race and BMI-matched) women were prospectively studied for body composition (by bioelectrical impedance analysis [BIA]) and basal IR and insulin secretion by the homeostasis model assessment (HOMA-IR and HOMA-%β-cell function, respectively) in a tertiary care academic referral center. A subset of 12 PCOS and 12 matched control women also underwent a modified frequently sampled intravenous glucose tolerance test (FSIVGTT) to determine glucose uptake and insulin secretion in dynamic state. MAIN RESULTS AND THE ROLE OF CHANCE Our results indicate that women with PCOS demonstrated greater degrees of hyperandrogenism, and higher waist-to-hip ratio (WHR), %body fat, fat BMI, F/L, fasting insulin levels, and HOMA-IR and HOMA-%β-cell values, than controls. In models adjusted for WHR and free testosterone and diagnostic groups, fasting insulin levels, HOMA-IR, and HOMA-%beta cell function were positively related to the F/L ratio. A positive relationship was also found in both study groups between F/L and the FSIVGTT measures insulin sensitivity (Si) and acute insulin response to glucose (AIRg). The F/L tended to negatively correlate with glucose effectiveness or non-insulin-mediated glucose transport (Sg) only in PCOS women. LIMITATIONS, REASONS FOR CAUTION Regional tissue sub-compartments, which have been shown to have potential independent associations with metabolic variables, cannot be determined by bioelectrical impedance analysis (BIA). WIDER IMPLICATIONS OF THE FINDINGS The current results suggest that BIA could be used to assess F/L in place of dual energy X-ray absorptiometry (DXA) in research protocols, and that F/L could possibly be used as an alternative to WHR as a surrogate marker of metabolic dysfunction in clinical practice. STUDY FUNDING/COMPETING INTEREST(S) This work was supported by grants R01-DK073632 and R01-HD29364 from the NIH and an endowment of the Helping Hand of Los Angeles, Inc. (to R.A.). The authors have no competing interests to declare. TRIAL REGISTRATION NUMBER Not applicable. PMID:24813197
Steihaug, O M; Gjesdal, C G; Bogen, B; Ranhoff, A H
2016-01-01
Older hip fracture patients often have reduced muscle mass, which is associated with adverse outcomes. Dual energy X-ray absorptiometry (DXA) can determine muscle mass, but is not practical in the acute phase. We investigated bioelectrical impedance analysis (BIA) and anthropometry compared against DXA for detecting low muscle mass in hip fracture patients. This was a cross-sectional validation study at two Norwegian hospitals on 162 hip fracture patients aged ≥ 65 years. Appendicular lean mass (ALM) was determined by DXA, BIA and anthropometry 3 months after hip fracture. ALM by BIA was calculated by the Kyle, Janssen, Tengvall and Sergi equations, and ALM by anthropometry by the Heymsfield and Villani equations. The area under the receiver operating characteristic curve (AUC) was used to compare BIA and anthropometry for determining low ALM (≤5.67 kg/m2 for women and ≤7.25kg/m2 for men). Mean age was 79 years (SD 7.9), 74% were female. Mean ALM by DXA was 14.8 kg (SD 2.3) for women and 20.8 kg (SD 4.2) for men and 45% of women and 60% of men had low ALM. BIA (Kyle) in women (AUC 0.81, 95% confidence interval 0.72-0.89) and BIA (Sergi) in men (AUC 0.89, 95% CI 0.80-0.98) were best able to discriminate between low and normal ALM. Anthropometry (Heymsfield) was less accurate than BIA in women (AUC 0.64, 95% CI 0.54-0.75), and equal to BIA in men (AUC 0.72, 95% CI 0.72 0.56-0.87). BIA (Sergi, Kyle and Tengvall) and anthropometry (Heymsfield) can identify low muscle mass in hip fracture patients.
The role of IGF-1 and the distribution of body fat in decreasing the number of prostate rebiopsies.
Morán, E; Martínez, M; Budía, A; Broseta, E; Cámara, R; Boronat, F
2017-03-01
To assess the usefulness of IGF-1 and internal organ fat measured by bioelectrical impedance audiometry to avoid rebiopsies in patients with persistently high prostate-specific antigen (PSA) levels. A prospective study was conducted with 92 patients who underwent prostate rebiopsy due to high PSA levels with negative results in the rectal examination and a lack of preneoplastic lesions. The patients previously had their IGF-1 levels measured and had undergone an impedance audiometry test using the abdominal Fat Analyser AB-140 TANITA system. We calculated the receiver operating characteristic (ROC) curves for the PSA levels, %PSA, internal organ fat and IGF-1 and PSA density. Twenty-five patients were diagnosed with prostate cancer. These patients had significantly higher PSA, PSAd and IGF-1 values and a tendency towards higher internal organ fat levels and lower %PSA readings (p=.001, p=.003, p=.001, p=.24 and P=0.28, respectively). The ROC curve showed an area under the curve for IGF-1 and PSA of .82 and .81, respectively. Using the cutoff points for 95% sensitivity and using the 3 criteria as an indication of rebiopsy, 74% of the biopsies would have been spared, leaving undiagnosed only 1 patient with clinically significant cancer -Gleason score>7 (4+3)-. The positive and negative predictive values for the set of variables were higher than for each one separately (PPV: 66/NPV: 63). The cost of both determinations was 82 euros. Our results suggest that measuring IGF-1 could significantly decrease the number of unnecessary rebiopsies in an inexpensive and safe manner. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Technical Reports Server (NTRS)
Kuzmina, G. I.
1980-01-01
The effects of caloric and electric stimulation of the vestibular receptors on the EMG activity of limb muslces in anesthetized cats during cold induced shivering involved flexor muscles alone. Both types of stimulation suppressed bioelectrical activity more effectively in the ipsilateral muscles. The suppression of shivering activity seems to be due to the increased inhibitory effect of descending labyrinth pathways on the function of flexor motoneurons.
2010-01-01
Bioelectrics, Old Dominion University, Norfolk, VA 8. PERFORMING ORGANIZATION REPORT NUMBER 3 General Dynamics Inf. Tech Brooks City-Base, San... 16 . SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON a. REPORT U b. ABSTRACT...Sta tes of America, 2 Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, Virginia, United States of America, 3 General
NASA Astrophysics Data System (ADS)
Qiu, Rui; Zhang, Baogang; Li, Jiaxin; Lv, Qing; Wang, Song; Gu, Qian
2017-08-01
Microbial fuel cells (MFCs) represent a promising approach for remediation of toxic vanadium (V) contaminated environment. Herein, enhanced V(V) reduction and bioelectricity generation are realized in MFCs with biocathode. Synergistically electrochemical and microbial reductions result in the nearly complete removals of V(V) within 7 d operation with initial concentration of 200 mg L-1. Maximum power density of 529 ± 12 mW m-2 is obtained. Electrochemical tests reveal that biocathode promotes electron transfers and reduces charge transfer resistance. XPS analysis confirms that V(IV) is the main reduction product, which precipitates naturally under neutral conditions. High-throughput 16S rRNA gene sequencing analysis indicates that the newly appeared Dysgonomonas is responsible for V(V) reduction and Klebsiella contributes mainly to bioelectricity generation in MFCs with biocathode. This study further improves the performance of remediating V(V) contaminated environment based on MFC technology.
NASA Technical Reports Server (NTRS)
Bishop, Phillip A.
1989-01-01
Previous research has established that bioelectrical characteristics of the human body reflect fluid status to some extent. It has been previously assumed that changes in electrical resistance (R) and reactance (X) are associated with changes in total body water (TBW). The purpose of the present pilot investigation was to assess the correspondence between body R and X and changes in estimated TBW and plasma volume during a period of bedrest (simulated weightlessness). R and X were measured pre-, during, and post- a 13 day bedrest status. Although a clear relationship was not elucidated, evidence was found suggesting that R and X reflect plasma volume rather than TBW. Indirect evidence provided by previous studies which investigated other aspects of the electrical/fluid relationship, also suggests the independence of TBW and electrical properties. With further research, a bioelectrical technique for noninvasively tracking fluid changes consequent to space flight may be developed.
Conversion of Wastes to Bioelectricity, Bioethanol, and Fertilizer.
Khan, Abdul Majeed; Hussain, Muhammad Shoukat
2017-08-01
This research article presents production of bioelectricity, bioethanol, and fertilizer from different industrial wastewaters supplemented with waste fruit and vegetables. Bioelectricity was generated from wastewater through the development of different microbial fuel cells (MFCs). It was observed that the voltage was increased in series combination, whereas current was increased in parallel combinations. The series combination of four units of single-chamber and eight units of double-chamber MFCs produced the power output of 5.43 mW and 4.08 mW, respectively, which is sufficient to light up the light emitting diode (LED). Power output was increased by the addition of waste fruit and vegetables. The leftover filtrates of MFCs were used for the production of bioethanol using Saccharomyces cerevisiae, while residues were used as fertilizer to check the growth of okra plant. The result showed that minor amount of bioethanol is produced from different samples, which was confirmed by the preparation of ethylbenzoate derivative.
Heterogeneous silicon mesostructures for lipid-supported bioelectric interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Yuanwen; Carvalho-de-Souza, João L.; Wong, Raymond C. S.
Silicon-based materials have widespread application as biophysical tools and biomedical devices. Here we introduce a biocompatible and degradable mesostructured form of silicon with multi-scale structural and chemical heterogeneities. The material was synthesized using mesoporous silica as a template through a chemical vapour deposition process. It has an amorphous atomic structure, an ordered nanowire-based framework and random submicrometre voids, and shows an average Young’s modulus that is 2–3 orders of magnitude smaller than that of single-crystalline silicon. In addition, we used the heterogeneous silicon mesostructures to design a lipid-bilayer-supported bioelectric interface that is remotely controlled and temporally transient, and that permitsmore » non-genetic and subcellular optical modulation of the electrophysiology dynamics in single dorsal root ganglia neurons. Our findings suggest that the biomimetic expansion of silicon into heterogeneous and deformable forms can open up opportunities in extracellular biomaterial or bioelectric systems.« less
Heterogeneous silicon mesostructures for lipid-supported bioelectric interfaces
Jiang, Yuanwen; Carvalho-de-Souza, João L.; Wong, Raymond C. S.; Luo, Zhiqiang; Isheim, Dieter; Zuo, Xiaobing; Nicholls, Alan W.; Jung, Il Woong; Yue, Jiping; Liu, Di-Jia; Wang, Yucai; De Andrade, Vincent; Xiao, Xianghui; Navrazhnykh, Luizetta; Weiss, Dara E.; Wu, Xiaoyang; Seidman, David N.; Bezanilla, Francisco; Tian, Bozhi
2017-01-01
Silicon-based materials have widespread application as biophysical tools and biomedical devices. Here we introduce a biocompatible and degradable mesostructured form of silicon with multiscale structural and chemical heterogeneities. The material was synthesized using mesoporous silica as a template through a chemical-vapor-deposition process. It has an amorphous atomic structure, an ordered nanowire-based framework, and random submicrometre voids, and shows an average Young’s modulus that is 2–3 orders of magnitude smaller than that of single crystalline silicon. In addition, we used the heterogeneous silicon mesostructures to design a lipid-bilayer-supported bioelectric interface that is remotely controlled and temporally transient, and that permits non-genetic and subcellular optical modulation of the electrophysiology dynamics in single dorsal root ganglia neurons. Our findings suggest that the biomimetic expansion of silicon into heterogeneous and deformable forms can open up opportunities in extracellular biomaterial or bioelectric systems. PMID:27348576
Skin-electrode impedance measurement during ECG acquisition: method’s validation
NASA Astrophysics Data System (ADS)
Casal, Leonardo; La Mura, Guillermo
2016-04-01
Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.
Comparative Study of Impedance Eduction Methods, Part 2: NASA Tests and Methodology
NASA Technical Reports Server (NTRS)
Jones, Michael G.; Watson, Willie R.; Howerton, Brian M.; Busse-Gerstengarbe, Stefan
2013-01-01
A number of methods have been developed at NASA Langley Research Center for eduction of the acoustic impedance of sound-absorbing liners mounted in the wall of a flow duct. This investigation uses methods based on the Pridmore-Brown and convected Helmholtz equations to study the acoustic behavior of a single-layer, conventional liner fabricated by the German Aerospace Center and tested in the NASA Langley Grazing Flow Impedance Tube. Two key assumptions are explored in this portion of the investigation. First, a comparison of results achieved with uniform-flow and shear-flow impedance eduction methods is considered. Also, an approach based on the Prony method is used to extend these methods from single-mode to multi-mode implementations. Finally, a detailed investigation into the effects of harmonic distortion on the educed impedance is performed, and the results are used to develop guidelines regarding acceptable levels of harmonic distortion
NASA Astrophysics Data System (ADS)
Yoshizawa, Masasumi; Nakamura, Yuuta; Ishiguro, Masataka; Moriya, Tadashi
2007-07-01
In this paper, we describe a method of compensating the attenuation of the ultrasound caused by soft tissue in the transducer vibration method for the measurement of the acoustic impedance of in vivo bone. In the in vivo measurement, the acoustic impedance of bone is measured through soft tissue; therefore, the amplitude of the ultrasound reflected from the bone is attenuated. This attenuation causes an error of the order of -20 to -30% when the acoustic impedance is determined from the measured signals. To compensate the attenuation, the attenuation coefficient and length of the soft tissue are measured by the transducer vibration method. In the experiment using a phantom, this method allows the measurement of the acoustic impedance typically with an error as small as -8 to 10%.
Sarcopenia is related to increased risk for low bone mineral density.
Wu, Chia-Hung; Yang, Kun-Cheh; Chang, Hao-Hsiang; Yen, Jo-Fang; Tsai, Ko-Sung; Huang, Kuo-Chin
2013-01-01
Lean body mass is positively correlated with bone mineral density (BMD). The association between sarcopenia and BMD is less studied. The aim of the study is to investigate the association between sarcopenia and abnormal BMD. A total of 600 community residents aged 40-85 years (mean=63.63 ± 10.12) from Taipei, Taiwan were included. Abnormal and normal BMD groups were categorized by T-score of femoral neck and lumbar spine (L2-L4) measured by dual-energy X-ray absorptiometry. Skeletal muscle mass (SM) index (SMI) was obtained from SM divided by height squared using bioelectrical impedance analysis (BIA) method. Sarcopenia was defined as SMI less than 8.87 kg/m² in men and 6.42 kg/m² in women according to previous Taiwanese sarcopenia study. The association between BMD groups and sarcopenia was examined using binary logistic regression analyses after controlling potential confounders. Subjects with sarcopenia were at higher risk for low BMD (odds ratio (OR) = 1.59, 95% confidence interval (CI)=1.06-2.39 for femoral neck BMD and OR=1.72, 95% CI=1.09-2.72 for lumbar BMD) compared with the nonsarcopenia group. Even in different gender groups with age categorized, sarcopenia was still an important independent factor in female group. The least square (LS) means of BMD of femoral neck and lumbar spine were significantly lower in sarcopenia group. The risk of low BMD increased significantly with sarcopenia. Copyright © 2013 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Toward Body Composition Reference Data for Infants, Children, and Adolescents123
Wells, Jonathan C. K.
2014-01-01
Growth charts for weight and height have provided the basis for assessment of children’s nutritional status for over half a century, with charts for body mass index (BMI) introduced in the 1990s. However, BMI does not provide information on the proportions of fat and lean mass; and within the past decade, growth charts for children’s body composition have been produced by using techniques such as skinfold thicknesses, body circumferences, bioelectrical impedance analysis (BIA), and dual-energy X-ray absorptiometry (DXA). For public health research, BIA and skinfold thicknesses show negligible average bias but have wider limits of agreement than specialized techniques. For patients, DXA is the best individual method, but multicomponent models remain ideal because they address perturbations in lean mass composition. Data can be expressed in age- and sex-specific SD scores, in some cases adjusting for height. Most such reference data derive from high-income countries, but techniques such as air-displacement plethysmography allow infant body composition growth charts to be developed in low- and middle-income settings, where the data may improve understanding of the effects of low birth weight, wasting, and stunting on body composition. Recent studies suggest that between-population variability in body composition may derive in part from genetic factors, suggesting a universal human body composition reference may not be viable. Body composition growth charts may be extended into adult life to evaluate changes in fat and lean mass through the entire life course. These reference data will improve the understanding of the association between growth, body composition, health, and disease. PMID:24829484
Toward body composition reference data for infants, children, and adolescents.
Wells, Jonathan C K
2014-05-01
Growth charts for weight and height have provided the basis for assessment of children's nutritional status for over half a century, with charts for body mass index (BMI) introduced in the 1990s. However, BMI does not provide information on the proportions of fat and lean mass; and within the past decade, growth charts for children's body composition have been produced by using techniques such as skinfold thicknesses, body circumferences, bioelectrical impedance analysis (BIA), and dual-energy X-ray absorptiometry (DXA). For public health research, BIA and skinfold thicknesses show negligible average bias but have wider limits of agreement than specialized techniques. For patients, DXA is the best individual method, but multicomponent models remain ideal because they address perturbations in lean mass composition. Data can be expressed in age- and sex-specific SD scores, in some cases adjusting for height. Most such reference data derive from high-income countries, but techniques such as air-displacement plethysmography allow infant body composition growth charts to be developed in low- and middle-income settings, where the data may improve understanding of the effects of low birth weight, wasting, and stunting on body composition. Recent studies suggest that between-population variability in body composition may derive in part from genetic factors, suggesting a universal human body composition reference may not be viable. Body composition growth charts may be extended into adult life to evaluate changes in fat and lean mass through the entire life course. These reference data will improve the understanding of the association between growth, body composition, health, and disease. © 2014 American Society for Nutrition.
Increased Urine Production Due to Leg Fluid Displacement Reduces Hours of Undisturbed Sleep.
Kiba, Keisuke; Hirayama, Akihide; Yoshikawa, Motokiyo; Yamamoto, Yutaka; Torimoto, Kazumasa; Shimizu, Nobutaka; Tanaka, Nobumichi; Fujimoto, Kiyohide; Uemura, Hirotsugu
2017-07-03
To investigate whether or not the leg fluid displacement observed when moving from the standing to recumbent position at bedtime reduces the hours of undisturbed sleep (HUS). Men aged 50 years or older who were hospitalized for urological diseases were investigated. Body water evaluation was performed three times with a bioelectric impedance method: (i) 17:00, (ii) 30 min after (short-term), and (iii) waking up (long-term). A frequency volume chart was used to evaluate the status of nocturnal urine production, and the factors affecting HUS were investigated. A total of 50 patients (mean age: 68 years) were enrolled. Short-term changes in extracellular fluid (ECF in the legs showed a significant positive correlation with urine production per unit of time at the first nocturnal voiding (UFN/HUS) (r = 0.45, P = 0.01). In the comparison between patients who had <3 HUS vs. those who had ≥3 HUS, the <3 HUS group showed significantly greater short-term changes in leg fluid volume, night-time water intake (17:00-06:00), and UFN/HUS. Multivariate analysis to assess the risk factors for <3 HUS indicated UFN/HUS as a risk factor in the overall model, and short-term changes in leg ECF and night-time water intake as risk factors in the model that only considered factors before sleep. Nocturnal leg fluid displacement may increase urine production leading up to first voiding after going to bed, and consequently, induce early awakening after falling asleep. © 2017 John Wiley & Sons Australia, Ltd.
Phase angle as a nutritional evaluation tool in all stages of chronic liver disease.
Peres, W A F; Lento, D F; Baluz, K; Ramalho, A
2012-01-01
Malnutrition is commonly and frequently under-diagnosed in clinical settings in patients with chronic liver disease (CLD) due to the limitations of nutritional evaluation methods in this population. We hypothesized that the bioelectrical impedance analysis derived phase angle (BIA-derived PhA) might be considered as a nutritional indicator in CLD since it represents either cell death or malnutrition characterized by changes in cellular membrane integrity. The aim of this study was to evaluate the BIA-derived PhA as a nutritional evaluation tool in all stages of CLD, including chronic hepatitis, liver cirrhosis and hepatocellular carcinoma (HCC). Liver-related death and survival were evaluated. A total of 66 patients were enrolled in a cross-sectional study. For the nutritional diagnosis, mid-arm circumference (MAC), triceps skinfold thickness (TST), mid-arm muscle circumference (MAMC) and Subject Global Assessment (SGA) were evaluated. Biochemical and clinical evaluations were performed. Our results showed that PhA was higher in well-nourished patients, according to SGA and in the patients without hepatic encephalopathy. PhA correlated significantly with MAMC, MAC and albumin and was inversely correlated with age. No correlation was found between PhA values and the Child-Pugh score and ascites. PhA was strongly associated with survival and PhA ≤ 5.18º with relative risk increase of 2.5 for death. We conclude that the BIA-derived PhA is a relevant nutritional evaluation tool in chronic hepatitis, liver cirrhosis and HCC and the role of PhA in the prediction of survival in CLD should be examined further in a controlled study.
Sarcopenia and post-hospital outcomes in older adults: A longitudinal study.
Pérez-Zepeda, Mario Ulises; Sgaravatti, Aldo; Dent, Elsa
Sarcopenia poses a significant problem for older adults, yet very little is known about this medical condition in the hospital setting. The aims of this hospital-based study were to determine: (i) the prevalence of sarcopenia; (ii) factors associated with sarcopenia; and (iii) the association of sarcopenia with adverse clinical outcomes post-hospitalisation. This is a longitudinal analysis of consecutive patients aged ≥70 years admitted to a Geriatric Management and Evaluation Unit (GEMU) ward. Sarcopenia was classified using the European Working Group on Sarcopenia in Older People (EWGSOP) algorithm, which included: handgrip strength, gait speed, and muscle mass using Bioelectrical Impedance Analysis (BIA). Outcomes were assessed at 12-months post-hospital discharge, and included both mortality and admission to a hospital Emergency Department (ED). Kaplan-Meier methods were used to estimate survival, with Cox proportion hazard models then applied. All regression analyses controlled for age, sex, and co-morbidity. 172 patients (72% female) with a mean (SD) age of 85.2 (6.4) years were included. Sarcopenia was present in 69 (40.1%) of patients. Patients with sarcopenia were twice as likely to die in the 12-months post-hospitalisation (HR, 95% CI=2.23, 1.15-4.34), but did not have an increased likelihood of ED admission. Sarcopenia showed an independent association with 12-month post-hospital mortality in older adults. With the new recognition of sarcopenia as a medical condition with its own unique ICD-10-CM code, awareness and diagnosis of sarcopenia in clinical settings is paramount. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Okada, Yoko; Ochi, Masayuki; Ohara, Maya; Nagai, Tokihisa; Tabara, Yasuharu; Igase, Michiya
2017-01-01
Abstract Background There is a close association between frailty and cognitive impairment. However, the underlying contribution of sarcopenia to the development of cognitive impairment is unclear. We investigated the possible association between muscle mass decline and cognitive impairment in a cross‐sectional study of 1518 subjects aged 55 years or above. We also evaluated arterial stiffness and white matter hyperintensities (WMHs) as possible underlying mechanisms for this association. Methods Two sarcopenic indices were measured: thigh muscle cross‐sectional area (CSA; calculated by computed tomography) and skeletal muscle mass (bioelectric impedance). Muscle mass decline was defined as either the bottom 10% or 20% of participants for each sex. Cognitive function was assessed using the Touch Panel‐type Dementia Assessment Scale, and brachial–ankle pulse wave velocity was measured as an index of arterial stiffness. Results Both sarcopenic indices were modestly but significantly associated with brachial–ankle pulse wave velocity in male and female subjects. The presence of WMHs was significantly associated with low thigh muscle CSA in men and with low skeletal muscle mass in women. The Touch Panel‐type Dementia Assessment Scale score was modestly but significantly and positively associated with thigh muscle CSA in men and skeletal muscle mass in women. Muscle mass decline in the bottom 10% of participants on both sarcopenic indices was significantly and independently related to cognitive impairment in women. Conclusions Lower sarcopenic indices are significantly related to lower cognitive scores. Arterial stiffness and WMHs could account, at least in part, for this association. PMID:28371474
An increase in visceral fat is associated with a decrease in the taste and olfactory capacity
Fernandez-Garcia, Jose Carlos; Alcaide, Juan; Santiago-Fernandez, Concepcion; Roca-Rodriguez, MM.; Aguera, Zaida; Baños, Rosa; Botella, Cristina; de la Torre, Rafael; Fernandez-Real, Jose M.; Fruhbeck, Gema; Gomez-Ambrosi, Javier; Jimenez-Murcia, Susana; Menchon, Jose M.; Casanueva, Felipe F.; Fernandez-Aranda, Fernando; Tinahones, Francisco J.; Garrido-Sanchez, Lourdes
2017-01-01
Introduction Sensory factors may play an important role in the determination of appetite and food choices. Also, some adipokines may alter or predict the perception and pleasantness of specific odors. We aimed to analyze differences in smell–taste capacity between females with different weights and relate them with fat and fat-free mass, visceral fat, and several adipokines. Materials and methods 179 females with different weights (from low weight to morbid obesity) were studied. We analyzed the relation between fat, fat-free mass, visceral fat (indirectly estimated by bioelectrical impedance analysis with visceral fat rating (VFR)), leptin, adiponectin and visfatin. The smell and taste assessments were performed through the "Sniffin’ Sticks" and "Taste Strips" respectively. Results We found a lower score in the measurement of smell (TDI-score (Threshold, Discrimination and Identification)) in obese subjects. All the olfactory functions measured, such as threshold, discrimination, identification and the TDI-score, correlated negatively with age, body mass index (BMI), leptin, fat mass, fat-free mass and VFR. In a multiple linear regression model, VFR mainly predicted the TDI-score. With regard to the taste function measurements, the normal weight subjects showed a higher score of taste functions. However a tendency to decrease was observed in the groups with greater or lesser BMI. In a multiple linear regression model VFR and age mainly predicted the total taste scores. Discussion We show for the first time that a reverse relationship exists between visceral fat and sensory signals, such as smell and taste, across a population with different body weight conditions. PMID:28158237
Neves, Felipe Silva; Leandro, Danielle Aparecida Barbosa; Silva, Fabiana Almeida da; Netto, Michele Pereira; Oliveira, Renata Maria Souza; Cândido, Ana Paula Carlos
2015-01-01
To analyze the predictive capacity of the vertical segmental tetrapolar bioimpedance apparatus in the detection of excess weight in adolescents, using tetrapolar bioelectrical impedance as a reference. This was a cross-sectional study conducted with 411 students aged between 10 and 14 years, of both genders, enrolled in public and private schools, selected by a simple and stratified random sampling process according to the gender, age, and proportion in each institution. The sample was evaluated by the anthropometric method and underwent a body composition analysis using vertical bipolar, horizontal tetrapolar, and vertical segmental tetrapolar assessment. The ROC curve was constructed based on calculations of sensitivity and specificity for each point of the different possible measurements of body fat. The statistical analysis used Student's t-test, Pearson's correlation coefficient, and McNemar's chi-squared test. Subsequently, the variables were interpreted using SPSS software, version 17.0. Of the total sample, 53.7% were girls and 46.3%, boys. Of the total, 20% and 12.5% had overweight and obesity, respectively. The body segment measurement charts showed high values of sensitivity and specificity and high areas under the ROC curve, ranging from 0.83 to 0.95 for girls and 0.92 to 0.98 for boys, suggesting a slightly higher performance for the male gender. Body fat percentage was the most efficient criterion to detect overweight, while the trunk segmental fat was the least accurate indicator. The apparatus demonstrated good performance to predict excess weight. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Ramírez, E; Valencia, M E; Bourges, H; Espinosa, T; Moya-Camarena, S Y; Salazar, G; Alemán-Mateo, H
2012-10-01
Obesity and undernutrition co-exist in many regions of Mexico. However, accurate assessments are difficult because epidemiological data on body composition are not available. The aim of this study was to facilitate assessments of body composition in Mexican school children of different geographical regions and ethnicity by developing equations for bioelectrical impedance and anthropometry based on deuterium oxide dilution. We evaluated 336 subjects (143 belonged to six major indigenous groups) from Northern, Central and Southern Mexico. We measured height (Ht), weight (Wt), tricipital skinfold (Tricp-SKF) and resistance (R) based on a bioimpedance analysis (BIA). Fat-free mass (FFM) and fat mass (FM) were estimated from measurements of total body water with the deuterium dilution technique. The final BIA equation was FFM (kg)=0.661 × Ht²/R+0.200 × Wt-0.320. The R² was 0.96; the square root of the mean square error (SRMSE) was 1.39 kg. The final anthropometric equation was FM (kg)=-1.067 × sex+0.458 × Tricp-SKF+0.263 × Wt-5.407. The R² was 0.91; SRMSE was 1.60 kg. The BIA equation had a bias of 0.095 kg and precision of 1.43 kg. The anthropometric equation had a bias of 0.047 kg and precision of 1.58 kg. We validated two equations for evaluating body composition in Mexican indigenous and non-indigenous children and youth from three main regions of the country. These equations provided reliable estimates and will promote a better understanding of both obesity and undernutrition.
Socioeconomic status indicators, physical activity, and overweight/obesity in Brazilian children
Matsudo, Victor Keihan Rodrigues; Ferrari, Gerson Luis de Moraes; Araújo, Timóteo Leandro; Oliveira, Luis Carlos; Mire, Emily; Barreira, Tiago V; Tudor-Locke, Catrine; Katzmarzyk, Peter
2016-01-01
Abstract Objective: To analyze the associations between socioeconomic status (SES) indicators and physical activity and overweight/obesity in children. Methods: 485 children wore accelerometers for 7 days. Variables included time in sedentary behavior and moderate-to-vigorous physical activity (MVPA), and steps/day. Children were further categorized as meeting or not meeting guidelines of ≥60min/day MVPA and ≥12,000 steps/day. Body mass index (BMI) and body fat percentage (BF%) were measured using bioelectrical impedance. Overweight/obesity was defined as BMI >+1 SD and BF% ≥85th percentile. Parents answered questionnaires that questioned total annual household income, parental education level, parental employment status and automobile ownership. Results: Children averaged 59.5min/day in MVPA (44.1% met MVPA guidelines), and 9639 steps/day (18.4% met steps/day guidelines). 45.4% and 33% were overweight/obese classified by BMI and BF% respectively. Higher relative total annual household income level (Odds Ratio 0.31; 95% confidence interval=0.15-0.65), and relatively higher maternal (OR=0.38; 95%CI=0.20-0.72) and paternal (OR=0.36; 95%CI=0.17-0.75) education levels were associated with lower odds of children meeting MVPA guidelines. Household automobile ownership was associated with lower odds of children meeting MVPA (OR=0.48; 95%CI=0.31-0.75) and steps/day guidelines (OR=0.44; 95%CI=0.26-0.74). Conclusions: SES indicators were not associated with overweight/obesity, but higher SES was associated with lower odds of children meeting MVPA guidelines. PMID:26975562
Comparison of body composition methods during weight loss in obese women using herbal formula.
Kim, Ho-Jun; Gallagher, Dympna; Song, Mi-Yeon
2005-01-01
Bioelectrical impedance analysis (BIA), a device that analyzes the current conduction differences between the fat and water components is widely used for reasons that include convenience of use, non-invasiveness, safety, and low cost. Dual energy X-ray absorptiometry (DXA) allows for the assessment of total body and regional lean and fat tissues and bone mineral content (BMC). The objective of this study was to compare body composition assessments by BIA and DXA before and after a 6-week herbal diet intervention program in 50 pre-menopausal women [mean +/- SD: age 30.58 +/- 6.15, body mass index (BMI) 31.72 +/- 3.78]. Waist-to-hip ratio (WHR) was measured by BIA and anthropometry. Lean body mass (LBM), body fat (BF), BMC and percent body fat (%BF) were measured by BIA and DXA. Highly significant correlations were observed between BIA and DXA measurements for LBM, BF, BMC and %BF (r = 0.73, 0.93, 0.53, 0.79, respectively) before the intervention. Differences between BIA and DXA measurements were observed in LBM, BF, %BF and BMC before intervention (p < 0.01) where WHR by BIA was significantly higher compared to anthropometry before (p < 0.01) and after the intervention (p < 0.01). BIA underestimated LBM by 1.85 kg and overestimated BF by 2.54 kg compared to DXA before the intervention. Although BIA and DXA showed highly significant correlations for LBM, BF, BMC and %BF before the intervention, they did not produce statistically comparable results in pre-menopausal Korean women and therefore should not be used interchangeably when measuring body composition.
[Sarcopenic obesity and physical fitness in octogenarians: the multi-center EXERNET Project].
Muñoz-Arribas, Alberto; Mata, Esmeralda; Pedrero-Chamizo, Raquel; Espino, Luis; Gusi, Narcis; Villa, Gerardo; Gonzalez-Gross, Marcela; Casajús, José Antonio; Ara, Ignacio; Gómez-Cabello, Alba
2013-11-01
The aim of this study was to analyze the usefulness of different fitness test to detect the risk of sarcopenic obesity (SO) in octogenarian people. 306 subjects (76 men, 230 women) with a mean age of 82.5 ± 2.3 years from the Multi-center EXERNET Project sample fulfilled the inclusion criteria. Body composition was assessed in all subjects by bioelectrical impedance. Four groups were created based on the percentage of fat mass and muscle mass: 1) normal, 2) high fat mass, 3) low muscle mass and 4) SO. Physical fitness was assessed using 8 different tests modified from the batteries “Senior Fitness Test” and Eurofit (EXERNET battery). The risk of suffering SO depending on the fitness level was studied by logistic regression. Among the studied physical fitness tests, those that better predicted the risk of SO were leg strength, arm strength, agility, walking speed and balance in men; 95% CI [(0.606-0.957) (0.496-0.882), (0.020-2.014), (0.17-1.39), (0.913-1.002), all p < 0.05, except balance test (p = 0.07)] and balance test and agility in women; (95% CI [(0.928-1.002) (0.983-1.408), (both p = 0.07)]. Adequate levels of physical fitness are associated with a lower risk of SO. Some easy fitness tests seem to be useful for the detection of SO in those cases where the body-composition required methods for diagnosis are not available. Copyright AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.
Selective neural activation in a histologically derived model of peripheral nerve
NASA Astrophysics Data System (ADS)
Butson, Christopher R.; Miller, Ian O.; Normann, Richard A.; Clark, Gregory A.
2011-06-01
Functional electrical stimulation (FES) is a general term for therapeutic methods that use electrical stimulation to aid or replace lost ability. For FES systems that communicate with the nervous system, one critical component is the electrode interface through which the machine-body information transfer must occur. In this paper, we examine the influence of inhomogeneous tissue conductivities and positions of nodes of Ranvier on activation of myelinated axons for neuromuscular control as a function of electrode configuration. To evaluate these effects, we developed a high-resolution bioelectric model of a fascicle from a stained cross-section of cat sciatic nerve. The model was constructed by digitizing a fixed specimen of peripheral nerve, extruding the image along the axis of the nerve, and assigning each anatomical component to one of several different tissue types. Electrodes were represented by current sources in monopolar, transverse bipolar, and longitudinal bipolar configurations; neural activation was determined using coupled field-neuron simulations with myelinated axon cable models. We found that the use of an isotropic tissue medium overestimated neural activation thresholds compared with the use of physiologically based, inhomogeneous tissue medium, even after controlling for mean impedance levels. Additionally, the positions of the cathodic sources relative to the nodes of Ranvier had substantial effects on activation, and these effects were modulated by the electrode configuration. Our results indicate that physiologically based tissue properties cause considerable variability in the neural response, and the inclusion of these properties is an important component in accurately predicting activation. The results are used to suggest new electrode designs to enable selective stimulation of small diameter fibers.
2013-01-01
Background The purpose of this study was to examine maturity-related differences in anthropometry and body composition in Japanese youth within a single year. Methods Two hundred and ten Japanese youth aged from 13 to 13.99 years participated in this study. Their maturity status was assessed using a self-assessment of stage of pubic hair development. Bioelectrical impedance analysis was used to estimate percent body fat and lean body mass (LBM). Muscle thickness of the anterior thigh, posterior lower leg and rectus abdominis muscles were measured by ultrasound. Results For boys, height, body weight, and LBM in less mature groups were lower than that in more mature groups. The maturity-related differences were still significant after adjusting for chronological age. On the other hand, muscle thickness values in the lower extremity and abdomen differed among the groups at different stages of pubic hair development, whereas there was no maturity-related difference in the relative values corrected by LBM, except for those thickness values measured at the abdomen. For girls, only the muscle thickness at the anterior thigh and muscle thickness relative to LBM1/3 at the posterior lower leg was significantly affected by maturity status, but significant maturity-related difference was not found after adjusting for chronological age. Conclusions At least for Japanese boys and girls aged 13 years, maturity status affected body size in boys, but not in girls, and the influence of maturation on the muscularity of the lower extremity and trunk muscles is less in both sexes. PMID:23497570
Lyra, Arthur; Bonfitto, Alexandre José; Barbosa, Vera Lucia P; Bezerra, Ana Cristina; Longui, Carlos Alberto; Monte, Osmar; Kochi, Cristiane
2015-01-01
To compare the body composition of overweight children and adolescents by bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA) before and after physical activity program. One hundred and eleven patients with mean age (SD) of 12 (1.9) participated in the study. We assessed the weight, height, waist circumference (WC), and body composition by DXA and BIA. Patients underwent a program of diet and physical activity (1 h 30 min/day, 3 times a week for 3 months) and were evaluated before and after this period. Mean initial zBMI were 2.3 (0.5) and waist SDS 5.9 (1.8). Significant differences were observed when we compared the measurements taken by DXA and BIA, respectively: total body fat percentage (40 and 31.5) and fat-free mass (43.1 and 50.6 kg). Regarding the trunk fat by DXA, there was a positive correlation with the WC/height ratio (r = 0.65; p < 0.01). After the intervention period, we observed a reduction in the zBMI, waist SDS, and total body fat and increase of fat-free mass by DXA. BIA only detected reduction in fat. BIA underestimates the percentage of fat and overestimates fat-free mass in relation to DXA. There is positive correlation between trunk fat and the ratio WC/height. In addition, DXA detected changes in body composition induced by a short period of physical training, unlike BIA. © 2014 S. Karger AG, Basel.
Clinical anthropometrics and body composition from 3D whole-body surface scans
Ng, BK; Hinton, BJ; Fan, B; Kanaya, AM; Shepherd, JA
2017-01-01
BACKGROUND/OBJECTIVES Obesity is a significant worldwide epidemic that necessitates accessible tools for robust body composition analysis. We investigated whether widely available 3D body surface scanners can provide clinically relevant direct anthropometrics (circumferences, areas and volumes) and body composition estimates (regional fat/lean masses). SUBJECTS/METHODS Thirty-nine healthy adults stratified by age, sex and body mass index (BMI) underwent whole-body 3D scans, dual energy X-ray absorptiometry (DXA), air displacement plethysmography and tape measurements. Linear regressions were performed to assess agreement between 3D measurements and criterion methods. Linear models were derived to predict DXA body composition from 3D scan measurements. Thirty-seven external fitness center users underwent 3D scans and bioelectrical impedance analysis for model validation. RESULTS 3D body scan measurements correlated strongly to criterion methods: waist circumference R2 = 0.95, hip circumference R2 = 0.92, surface area R2 = 0.97 and volume R2 = 0.99. However, systematic differences were observed for each measure due to discrepancies in landmark positioning. Predictive body composition equations showed strong agreement for whole body (fat mass R2 = 0.95, root mean square error (RMSE) = 2.4 kg; fat-free mass R2 = 0.96, RMSE = 2.2 kg) and arms, legs and trunk (R2 = 0.79–0.94, RMSE = 0.5–1.7 kg). Visceral fat prediction showed moderate agreement (R2 = 0.75, RMSE = 0.11 kg). CONCLUSIONS 3D surface scanners offer precise and stable automated measurements of body shape and composition. Software updates may be needed to resolve measurement biases resulting from landmark positioning discrepancies. Further studies are justified to elucidate relationships between body shape, composition and metabolic health across sex, age, BMI and ethnicity groups, as well as in those with metabolic disorders. PMID:27329614
Effect of Body Composition Methodology on Heritability Estimation of Body Fatness
Elder, Sonya J.; Roberts, Susan B.; McCrory, Megan A.; Das, Sai Krupa; Fuss, Paul J.; Pittas, Anastassios G.; Greenberg, Andrew S.; Heymsfield, Steven B.; Dawson-Hughes, Bess; Bouchard, Thomas J.; Saltzman, Edward; Neale, Michael C.
2014-01-01
Heritability estimates of human body fatness vary widely and the contribution of body composition methodology to this variability is unknown. The effect of body composition methodology on estimations of genetic and environmental contributions to body fatness variation was examined in 78 adult male and female monozygotic twin pairs reared apart or together. Body composition was assessed by six methods – body mass index (BMI), dual energy x-ray absorptiometry (DXA), underwater weighing (UWW), total body water (TBW), bioelectric impedance (BIA), and skinfold thickness. Body fatness was expressed as percent body fat, fat mass, and fat mass/height2 to assess the effect of body fatness expression on heritability estimates. Model-fitting multivariate analyses were used to assess the genetic and environmental components of variance. Mean BMI was 24.5 kg/m2 (range of 17.8–43.4 kg/m2). There was a significant effect of body composition methodology (p<0.001) on heritability estimates, with UWW giving the highest estimate (69%) and BIA giving the lowest estimate (47%) for fat mass/height2. Expression of body fatness as percent body fat resulted in significantly higher heritability estimates (on average 10.3% higher) compared to expression as fat mass/height2 (p=0.015). DXA and TBW methods expressing body fatness as fat mass/height2 gave the least biased heritability assessments, based on the small contribution of specific genetic factors to their genetic variance. A model combining DXA and TBW methods resulted in a relatively low FM/ht2 heritability estimate of 60%, and significant contributions of common and unique environmental factors (22% and 18%, respectively). The body fatness heritability estimate of 60% indicates a smaller contribution of genetic variance to total variance than many previous studies using less powerful research designs have indicated. The results also highlight the importance of environmental factors and possibly genotype by environmental interactions in the etiology of weight gain and the obesity epidemic. PMID:25067962
Development on electromagnetic impedance function modeling and its estimation
NASA Astrophysics Data System (ADS)
Sutarno, D.
2015-09-01
Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As exploration was forced into more difficult areas, the importance of MT and CSAMT, in conjunction with other techniques, has tended to grow continuously. However, there are obviously important and difficult problems remaining to be solved concerning our ability to collect process and interpret MT as well as CSAMT in complex 3D structural environments. This talk aim at reviewing and discussing the recent development on MT as well as CSAMT impedance functions modeling, and also some improvements on estimation procedures for the corresponding impedance functions. In MT impedance modeling, research efforts focus on developing numerical method for computing the impedance functions of three dimensionally (3-D) earth resistivity models. On that reason, 3-D finite elements numerical modeling for the impedances is developed based on edge element method. Whereas, in the CSAMT case, the efforts were focused to accomplish the non-plane wave problem in the corresponding impedance functions. Concerning estimation of MT and CSAMT impedance functions, researches were focused on improving quality of the estimates. On that objective, non-linear regression approach based on the robust M-estimators and the Hilbert transform operating on the causal transfer functions, were used to dealing with outliers (abnormal data) which are frequently superimposed on a normal ambient MT as well as CSAMT noise fields. As validated, the proposed MT impedance modeling method gives acceptable results for standard three dimensional resistivity models. Whilst, the full solution based modeling that accommodate the non-plane wave effect for CSAMT impedances is applied for all measurement zones, including near-, transition-as well as the far-field zones, and consequently the plane wave correction is no longer needed for the impedances. In the resulting robust impedance estimates, outlier contamination is removed and the self consistency between the real and imaginary parts of the impedance estimates is guaranteed. Using synthetic and real MT data, it is shown that the proposed robust estimation methods always yield impedance estimates which are better than the conventional least square (LS) estimation, even under condition of severe noise contamination. A recent development on the constrained robust CSAMT impedance estimation is also discussed. By using synthetic CSAMT data it is demonstrated that the proposed methods can produce usable CSAMT transfer functions for all measurement zones.
Development on electromagnetic impedance function modeling and its estimation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutarno, D., E-mail: Sutarno@fi.itb.ac.id
2015-09-30
Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As exploration was forced into more difficult areas, the importance of MT and CSAMT, in conjunction with other techniques, has tended to grow continuously. However, there are obviously important and difficult problems remaining to be solved concerning our ability to collect process and interpret MT as well as CSAMT in complex 3D structural environments. This talk aim atmore » reviewing and discussing the recent development on MT as well as CSAMT impedance functions modeling, and also some improvements on estimation procedures for the corresponding impedance functions. In MT impedance modeling, research efforts focus on developing numerical method for computing the impedance functions of three dimensionally (3-D) earth resistivity models. On that reason, 3-D finite elements numerical modeling for the impedances is developed based on edge element method. Whereas, in the CSAMT case, the efforts were focused to accomplish the non-plane wave problem in the corresponding impedance functions. Concerning estimation of MT and CSAMT impedance functions, researches were focused on improving quality of the estimates. On that objective, non-linear regression approach based on the robust M-estimators and the Hilbert transform operating on the causal transfer functions, were used to dealing with outliers (abnormal data) which are frequently superimposed on a normal ambient MT as well as CSAMT noise fields. As validated, the proposed MT impedance modeling method gives acceptable results for standard three dimensional resistivity models. Whilst, the full solution based modeling that accommodate the non-plane wave effect for CSAMT impedances is applied for all measurement zones, including near-, transition-as well as the far-field zones, and consequently the plane wave correction is no longer needed for the impedances. In the resulting robust impedance estimates, outlier contamination is removed and the self consistency between the real and imaginary parts of the impedance estimates is guaranteed. Using synthetic and real MT data, it is shown that the proposed robust estimation methods always yield impedance estimates which are better than the conventional least square (LS) estimation, even under condition of severe noise contamination. A recent development on the constrained robust CSAMT impedance estimation is also discussed. By using synthetic CSAMT data it is demonstrated that the proposed methods can produce usable CSAMT transfer functions for all measurement zones.« less
Nutritional status of children with coeliac disease.
Aurangzeb, B; Leach, S T; Lemberg, D A; Day, A S
2010-07-01
The main aim of this study was to assess the nutritional status of children with newly diagnosed Coeliac disease (CD)with comparison to matched controls. A further aim was to assess relationships between presentation patterns and nutrition in childhood CD. The nutritional status of newly diagnosed CD was assessed by anthropometry, Bioelectrical Impedance and serum leptin levels, and contrasted to age and gender matched controls. Twenty-five children with CD (mean age of 8.2 +/- 4.5 years) and 25 control children (mean age 8.1 +/- 4.4.) were enrolled. Thirteen (52%) children with CD had gastrointestinal symptoms with 14 having a family history of CD. At presentation 8.7% were wasted, 4.2% were stunted and 20.8% overweight, although none were obese. Mean height and weight for age, other nutritional parameters and serum leptin did not differ between the groups. Serum leptin correlated with BMI in both groups. Children with CD more commonly present with atypical symptoms than with classical features. Variations in nutrition (under to overnutrition) may be seen at diagnosis, without relationship to the presence of symptoms. Leptin levels were not altered specifically in the setting of CD. Nutritional assessment remains important in the assessment and management of CD in children.
Mupere, Ezekiel; Zalwango, Sarah; Chiunda, Allan; Okwera, Alphonse; Mugerwa, Roy; Whalen, Christopher
2010-03-01
We determined whether human immunodeficiency virus (HIV) infection affects body cell mass and fat mass wasting among adults with pulmonary tuberculosis (PTB). We screened 967 Ugandan adults for PTB and HIV infection in a cross-sectional study. We compared anthropometric and bioelectric impedance analysis (BIA) body composition parameters among HIV-seropositive and HIV-seronegative men and women with or without PTB by using a non-parametric test. We found that poor nutritional status associated with TB differed among men and women. Anthropometric and BIA body composition did not differ between HIV-seropositive and HIV-seronegative patients regardless of gender. Average weight group difference in men consisted of body cell mass and fat mass in equal proportions of 43%. In women, average weight group difference consisted predominantly of fat mass of 73% and body cell mass of 13%. Compared to individuals without TB, patients with TB had lower body mass index, weight, body cell mass, and fat mass regardless of gender and HIV status. Gender, but not HIV status, was associated with body composition changes in TB. TB appears to be the dominant factor driving the wasting process among co-infected patients. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Food prices and body fatness among youths.
Grossman, Michael; Tekin, Erdal; Wada, Roy
2014-01-01
We examine the effect of food prices on clinical measures of obesity, including body mass index (BMI) and percentage body fat (PBF) measures derived from bioelectrical impedance analysis (BIA) and dual energy X-ray absorptiometry (DXA), among youths ages 12 through 18 in the National Health and Nutrition Examination Survey. This is the first study to consider clinically measured levels of body composition rather than BMI to investigate the effects of food prices on obesity outcomes among youths classified by gender and race/ethnicity. Our findings suggest that increases in the real price per calorie of food for home consumption and the real price of fast-food restaurant food lead to improvements in obesity outcomes among youths. We also find that a rise in the real price of fruits and vegetables leads to increased obesity. Finally, our results indicate that measures of PBF derived from BIA and DXA are no less sensitive and in some cases more sensitive to the prices just mentioned than BMI, and serve an important role in demonstrating that rising food prices (except fruit and vegetable prices) are indeed associated with reductions in obesity rather than with reductions in body size proportions alone. Copyright © 2013 Elsevier B.V. All rights reserved.
New body fat prediction equations for severely obese patients.
Horie, Lilian Mika; Barbosa-Silva, Maria Cristina Gonzalez; Torrinhas, Raquel Susana; de Mello, Marco Túlio; Cecconello, Ivan; Waitzberg, Dan Linetzky
2008-06-01
Severe obesity imposes physical limitations to body composition assessment. Our aim was to compare body fat (BF) estimations of severely obese patients obtained by bioelectrical impedance (BIA) and air displacement plethysmography (ADP) for development of new equations for BF prediction. Severely obese subjects (83 female/36 male, mean age=41.6+/-11.6 years) had BF estimated by BIA and ADP. The agreement of the data was evaluated using Bland-Altman's graphic and concordance correlation coefficient (CCC). A multivariate regression analysis was performed to develop and validate new predictive equations. BF estimations from BIA (64.8+/-15 kg) and ADP (65.6+/-16.4 kg) did not differ (p>0.05, with good accuracy, precision, and CCC), but the Bland- Altman graphic showed a wide limit of agreement (-10.4; 8.8). The standard BIA equation overestimated BF in women (-1.3 kg) and underestimated BF in men (5.6 kg; p<0.05). Two BF new predictive equations were generated after BIA measurement, which predicted BF with higher accuracy, precision, CCC, and limits of agreement than the standard BIA equation. Standard BIA equations were inadequate for estimating BF in severely obese patients. Equations developed especially for this population provide more accurate BF assessment.
As'habi, Atefeh; Najafi, Iraj; Tabibi, Hadi; Hedayati, Mehdi
2018-01-01
Uremic sarcopenia and dynapenia are prevalent in chronic kidney disease patients, including dialysis patients. The present study was designed to determine the prevalence of sarcopenia and dynapenia and their determinants in peritoneal dialysis (PD) patients in Tehran, Iran. All eligible PD patients at the peritoneal dialysis centers of Tehran were included in this cross-sectional study. Skeletal muscle mass and muscle strength were assessed using bioelectrical impedance analysis and hand grip strength, respectively. Physical performance was determined by a 4-m walk gait speed test. The prevalence rates of dynapenia and sarcopenia were 43.0% and 11.5% in the PD patients, respectively. There were significant associations between the prevalence of dynapenia and the age of patients (P = .03), physical activity level (P = .04), and the presence of diabetes mellitus (P = .005). In addition, a significant association was found between the prevalence of sarcopenia and sex (P = .009). This study indicates that uremic sarcopenia and dynapenia are prevalent in PD patients in Tehran, Iran. These conditions may contribute to physical disability, decreased the quality of life, increased morbidity, and a high mortality rate. Therefore, prevention and treatment of uremic sarcopenia and dynapenia are necessary for Iranian PD patients.
Pollonini, Luca; Rajan, Nithin O; Xu, Shuai; Madala, Sridhar; Dacso, Clifford C
2012-04-01
Remote patient monitoring (RPM) holds great promise for reducing the burden of congestive heart failure (CHF). Improved sensor technology and effective predictive algorithms can anticipate sudden decompensation events. Enhanced telemonitoring systems would promote patient independence and facilitate communication between patients and their physicians. We report the development of a novel hand-held device, called Blue Box, capable of collecting and wirelessly transmitting key cardiac parameters derived from three integrated biosensors: 2 lead electrocardiogram (ECG), photoplethysmography and bioelectrical impedance (bioimpedance). Blue Box measurements include time intervals between consecutive ECG R-waves (RR interval), time duration of the ECG complex formed by the Q, R and S waves (QRS duration), bioimpedance, heart rate and systolic time intervals. In this study, we recruited 24 healthy subjects to collect several parameters measured by Blue Box and assess their value in correlating with cardiac output measured with Echo-Doppler. Linear correlation between the heart rate measured with Blue Box and cardiac output from Echo-Doppler had a group average correlation coefficient of 0.80. We found that systolic time intervals did not improve the model significantly. However, STIs did inversely correlate with increasing workloads.
Morgan, P J; Saunders, K L; Lubans, D R
2012-06-01
To evaluate the effect of a school-based obesity prevention programme on physical self-perception and key physical-activity related cognitions in adolescent boys from disadvantaged secondary schools. A secondary objective was to determine if any psychological changes were associated with improved weight status. Participants (n = 100, age = 14.3[0.6]) were randomized to the PALS (Physical Activity Leaders) intervention (n = 50) or a control group (n = 50) and assessed at baseline, 3- and 6-month follow up. Measures included BMI, BMI z-score and % body fat (bioelectrical impedance analysis). Students also completed the Children's Physical Self-Perception Profile and a physical activity-related cognitions questionnaire. The findings include secondary data analyses. Relative to the controls, the PALS group significantly increased their physical self worth (p = .01), perceived physical condition (p = .02), resistance training self efficacy (p < .001) and their use of physical activity behavioural strategies (p = .02). A school-based obesity prevention programme that targeted leadership skills improved psychological health in the physical domain in adolescent boys from disadvantaged schools. © 2012 The Authors. Pediatric Obesity © 2012 International Association for the Study of Obesity.
The effect of sitting and calf activity on leg fluid and snoring.
Singh, Bhajan; Yadollahi, Azadeh; Lyons, Owen; Alshaer, Hisham; Bradley, T Douglas
2017-06-01
Prolonged sitting may promote leg fluid retention that redistributes to the neck during sleep and contributes to snoring. This could be attenuated by calf activity while sitting. In 16 healthy non-obese subjects we measured leg fluid volume (LFV) below the knees using bioelectrical impedance while sitting for 4h, snoring using a portable BresoDx™ device, and Mallampati grade. Using a double cross-over study design, subjects were randomized to one of two arms and crossed-over one week later: control arm - no calf exercise while sitting; intervention arm - calf contraction against a pedal resistance while sitting. The effects of sitting±calf activity on LFV and snoring were compared. We found that LFV increased by 216±101.0ml (p<0.0001) after sitting. Calf activity while sitting attenuated LFV by 53.8ml (p<0.0001) and, in all five subjects with severe upper airway narrowing (Mallampati grade IV), reduced snoring duration (from 357±132.9 to 116.2±72.1s/h, p=0.02) suggesting reduced overnight rostral fluid shift to the neck. Copyright © 2017 Elsevier B.V. All rights reserved.
White, Erin; Slane, Jennifer D; Klump, Kelly L; Burt, S Alexandra; Pivarnik, Jim
2014-08-01
Knowing the extent to which genetic and environmental factors influence percent body fatness (%Fat) and physical activity (PA) would be beneficial, since both are tightly correlated with future health outcomes. Thus, the purpose was to evaluate sex differences in genetic and environmental influences on %Fat and physical activity behavior in male and female adolescent twins. Subjects were adolescent (age range 8.3 to 16.6 yr) twins. %Fat (n = 518 twins) was assessed by bioelectrical impedance analysis (BIA) and PA (n = 296 twins) was measured using 3-Day PA Recall. Each activity was converted to total MET-minutes. Univariate twin models were used to examine sex differences in genetic and environmental factors influencing %Fat and PA. %Fat was influenced by genetic effects in both boys and girls (88% and 90%, respectively), with slightly higher heritability estimates for girls. PA was influenced solely by environmental effects for both sexes with higher shared environmental influences in boys (66%) and higher nonshared effects in girls (67%). When developing interventions to increase PA in adolescents, it is important to consider the environment in which it takes place as it is the primary contributor to PA levels.
Pileggi, Vicky Nogueira; Scalize, Antonio Rodolpho Hakime; Camelo Junior, José Simon
2016-12-01
To compare the phase angle of patients with osteogenesis imperfecta treated at a tertiary university hospital with patients in a control group of healthy children, and to assess the nutritional status of these patients through the body mass index proposed by the World Health Organization. Cross-sectional study carried out in a university hospital that included seven patients with osteogenesis imperfecta and a control group of 17 healthy children of the same gender and age. Weight and height were measured and bioelectrical impedance was performed. Subsequently, the phase angle was calculated based on resistance and reactance values. The phase angle of the group of children with osteogenesis imperfecta was significantly lower than that of the control group (p<0.05). The body mass index criterion for age of the World Health Organization showed no difference between groups. Children with osteogenesis imperfecta have a nutritional risk detected by the phase angle, which is a useful tool for nutritional screening. The calculation result could help in the diet therapy of patients with osteogenesis imperfecta. Copyright © 2016 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Muscle performance, body fat, pain and function in the elderly with arthritis.
Dos Santos, Wagner Teixeira; Rodrigues, Erika de Carvalho; Mainenti, Míriam Raquel Meira
2014-01-01
To correlate muscule performance, body composition, pain and joint function in elderly people with gonarthrosis. 21 elderly patients were submitted to bioelectrical impedance analysis, dynamometry associated with electromyographic (EMG) evaluation of isometric knee extension, in addition to pain assessment by the Numeric Pain Intensity Scale and function assessment, by the Western Ontario and McMaster Universities (WOMAC) Osteoarthritis (OA) questionnaire. Correlations were checked by the Pearson's correlation coefficient. The sample characteristics were mean age 67.36 ± 4.21 years old, body fat percentage 40.57±6.15%, total WOMAC score 43.27 ± 16.32%, and maximum strength 19.95 ± 6.99 kgF. Pain during movement showed a statistical association with WOMAC physical activity domain (r = 0.47) and its general score (r = 0.51); pain intensity at night presented association with WOMAC stiffness domain (r = 0.55), in addition to the negative correlation with the slope values of the Medium Frequency of the EMG signal (r = - 0.57). pain intensity is correlated to functional incapacity in elderly people with knee OA and to a greater expression of fatigue in EMG signal. Levels of Evidence III, Study of non consecutive patients.
Jones, Louise R.
2015-01-01
Publications from the Avon Longitudinal Study of Parents and Children covering diet, growth, and obesity development during childhood are reviewed. Diet was assessed by food frequency questionnaires and food records. Growth data were collected by routine measurements, and in standardized clinics, body fatness was assessed by bioelectrical impedance and DXA (dual-energy X-ray absorptiometry) scans. Diets changed dramatically during the preschool period with an increase in the intake of free (added) sugars (12.3% rising to 16.4% of energy) that remained similar until adolescence. This was due to increased intake of energy-dense, nutrient-poor foods. Two periods of rapid growth were identified; infancy and mid-childhood (ages 7–11 y) and both were associated with obesity development. Diets with high energy density were associated with increasing fat mass from mid-childhood until adolescence. Genetic and dietary factors showed independent associations with increasing adiposity. At all ages studied, there were dietary inequalities related to maternal educational attainment that may influence inequalities found in obesity development. The Avon Longitudinal Study of Parents and Children has provided valuable insights into how disparities in diet and growth may affect the development of ill health in adulthood. PMID:26395342
Steinsbekk, Silje; Llewellyn, Clare H; Fildes, Alison; Wichstrøm, Lars
2017-05-30
Research suggests a role for both fat mass and muscle mass in appetite regulation, but the longitudinal relationships between them have not yet been examined in children. The present study therefore aimed to explore the prospective relationships between fat mass, muscle mass and the appetitive traits food responsiveness and satiety responsiveness in middle childhood. Food responsiveness and satiety responsiveness were measured using the parent-reported Children's Eating Behavior Questionnaire in a representative sample of Norwegian 6 year olds, followed up at 8 and 10 years of age (n = 807). Body composition was measured by bioelectrical impedance. Applying a structural equation modeling framework we found that higher fat mass predicted greater increases in food responsiveness over time, whereas greater muscle mass predicted decreases in satiety responsiveness. This pattern was consistent both from ages 6 to 8 and from ages 8 to 10 years. Our study is the first to reveal that fat mass and muscle mass predict distinct changes in different appetitive traits over time. Replication of findings in non-European populations are needed, as are studies of children in other age groups. Future studies should also aim to reveal the underlying mechanisms.
Rotor damage detection by using piezoelectric impedance
NASA Astrophysics Data System (ADS)
Qin, Y.; Tao, Y.; Mao, Y. F.
2016-04-01
Rotor is a core component of rotary machinery. Once the rotor has the damage, it may lead to a major accident. Thus the quantitative rotor damage detection method based on piezoelectric impedance is studied in this paper. With the governing equation of piezoelectric transducer (PZT) in a cylindrical coordinate, the displacement along the radius direction is derived. The charge of PZT is calculated by the electric displacement. Then, by the use of the obtained displacement and charge, an analytic piezoelectric impedance model of the rotor is built. Given the circular boundary condition of a rotor, annular elements are used as the analyzed objects and spectral element method is used to set up the damage detection model. The Electro-Mechanical (E/M) coupled impedance expression of an undamaged rotor is deduced with the application of a low-cost impedance test circuit. A Taylor expansion method is used to obtain the approximate E/M coupled impedance expression for the damaged rotor. After obtaining the difference between the undamaged and damaged rotor impedance, a rotor damage detection method is proposed. This method can directly calculate the change of bending stiffness of the structural elements, it follows that the rotor damage can be effectively detected. Finally, a preset damage configuration is used for the numerical simulation. The result shows that the quantitative damage detection algorithm based on spectral element method and piezoelectric impedance proposed in this paper can identify the location and the severity of the damaged rotor accurately.
The effect of subjection of the hypothalamus to electrocoagulation in the area of the mamillary bodies on the bioelectric activity and reactivity of...the cerebral cortex exposed to radiation was studied. Rabbits were irradiated on the 10th day after electrocoagulation . Immediately after... electrocoagulation , a decline in the excitability and functional activity of cortical neurons in the posterior section of the cortex and a decrease in the
Neĭmark, A I; Klyzhina, E A; Neĭmark, B A; Mel'nik, M A
2007-01-01
Urodynamic parameters and bioelectric brain activity were studied in 30 females aged 24-66 years with overactive bladder (OAB) before and after transcranial magnetotherapy. It was found that OAB patients have disorders of bioelectric brain activity by two types of EEG patterns (I.A. Svyatogor classification)--thalamic and stem, Patients with thalamic type EEG benefit more from magnetotherapy higher efficacy of which manifests with regress of clinical symptoms and urodynamic improvement.
Land-use and alternative bioenergy pathways for waste biomass.
Campbell, J E; Block, E
2010-11-15
Rapid escalation in biofuels consumption may lead to a trade regime that favors exports of food-based biofuels from tropical developing countries to developed countries. There is growing interest in mitigating the land-use impacts of these potential biofuels exports by converting biorefinery waste streams into cellulosic ethanol, potentially reducing the amount of land needed to meet production goals. This increased land-use efficiency for ethanol production may lower the land-use greenhouse gas emissions of ethanol but would come at the expense of converting the wastes into bioelectricity which may offset fossil fuel-based electricity and could provide a vital source of domestic electricity in developing countries. Here we compare these alternative uses of wastes with respect to environmental and energy security outcomes considering a range of electricity production efficiencies, ethanol yields, land-use scenarios, and energy offset assumptions. For a given amount of waste biomass, we found that using bioelectricity production to offset natural gas achieves 58% greater greenhouse gas reductions than using cellulosic ethanol to offset gasoline but similar emissions when cellulosic ethanol is used to offset the need for more sugar cane ethanol. If bioelectricity offsets low-carbon energy sources such as nuclear power then the liquid fuels pathway is preferred. Exports of cellulosic ethanol may have a small impact on the energy security of importing nations while bioelectricity production may have relatively large impacts on the energy security in developing countries.
Functional condition of masseters muscles of patients with class ?? subdivision.
Kuroyedova, Vera D; Makarova, Alexandra N; Chicor, Tatyana A
Main functional characteristics of masticator muscles in patients with class ?? malocclusions is activity dominance of m. temporalis in comparison with m. ?asseter. We have not found datum about functional status of the masticators in patients with class II subdivision. The purpose of our study was to investigate the functional characteristics of m. ?asseter, m. temporalis in adult patients with class II subdivision malocclusion. There have been carried out the surface electromyographic study of m. masseter, m. temporalis in 17 adult patients with class II subdivision. It was realized quantitative analysis of 271 electromyogram, it was determined the average bioelectric activity, index activity, symmetry and torsion index. It was observed predominance of the bioelectrical activity of m. temporales on m. masseter for all persons with class II subdivision. Bioelectrical activity for m. masseter was bigger on side of distal ratio and for m. temporales on side of neutral ratio. In class ?? subdivision right, the mandible was deviated to the left side and in class ?? subdivision left is deviated to the right side. Thus, rotational moment generated during compression of the jaws, causes deviation of the lower jaw to the side, with a neutral molar ratio. During voluntary chewing bioelectrical activity of m. masseter and m. temporalis was higher in the right side. In accordance with the functional condition of the masticatory muscles of class II subdivision is characterized with functional features of distal occlusion.
Time-domain representation of frequency-dependent foundation impedance functions
Safak, E.
2006-01-01
Foundation impedance functions provide a simple means to account for soil-structure interaction (SSI) when studying seismic response of structures. Impedance functions represent the dynamic stiffness of the soil media surrounding the foundation. The fact that impedance functions are frequency dependent makes it difficult to incorporate SSI in standard time-history analysis software. This paper introduces a simple method to convert frequency-dependent impedance functions into time-domain filters. The method is based on the least-squares approximation of impedance functions by ratios of two complex polynomials. Such ratios are equivalent, in the time-domain, to discrete-time recursive filters, which are simple finite-difference equations giving the relationship between foundation forces and displacements. These filters can easily be incorporated into standard time-history analysis programs. Three examples are presented to show the applications of the method.
Utilization of bone impedance for age estimation in postmortem cases.
Ishikawa, Noboru; Suganami, Hideki; Nishida, Atsushi; Miyamori, Daisuke; Kakiuchi, Yasuhiro; Yamada, Naotake; Wook-Cheol, Kim; Kubo, Toshikazu; Ikegaya, Hiroshi
2015-11-01
In the field of Forensic Medicine the number of unidentified cadavers has increased due to natural disasters and international terrorism. The age estimation is very important for identification of the victims. The degree of sagittal closure is one of such age estimation methods. However it is not widely accepted as a reliable method for age estimation. In this study, we have examined whether measuring impedance value (z-values) of the sagittal suture of the skull is related to the age in men and women and discussed the possibility to use bone impedance for age estimation. Bone impedance values increased with aging and decreased after the age of 64.5. Then we compared age estimation through the conventional visual method and the proposed bone impedance measurement technique. It is suggested that the bone impedance measuring technique may be of value to forensic science as a method of age estimation. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Impedance Eduction in Large Ducts Containing Higher-Order Modes and Grazing Flow
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.
2017-01-01
Impedance eduction test data are acquired in ducts with small and large cross-sectional areas at the NASA Langley Research Center. An improved data acquisition system in the large duct has resulted in increased control of the acoustic energy in source modes and more accurate resolution of higher-order duct modes compared to previous tests. Two impedance eduction methods that take advantage of the improved data acquisition to educe the liner impedance in grazing flow are presented. One method measures the axial propagation constant of a dominant mode in the liner test section (by implementing the Kumarsean and Tufts algorithm) and educes the impedance from an exact analytical expression. The second method solves numerically the convected Helmholtz equation and minimizes an objective function to obtain the liner impedance. The two methods are tested first on data synthesized from an exact mode solution and then on measured data. Results show that when the methods are applied to data acquired in the larger duct with a dominant higher-order mode, the same impedance spectra are educed as that obtained in the small duct where only the plane wave mode propagates. This result holds for each higher-order mode in the large duct provided that the higher-order mode is sufficiently attenuated by the liner.
Bio-isolated dc operational amplifier. [for bioelectric measurements
NASA Technical Reports Server (NTRS)
Lee, R. D. (Inventor)
1974-01-01
A bio-isolated dc operational amplifier is described for use in making bioelectrical measurements of a patient while providing isolation of the patient from electrical shocks. The circuit contains a first operational amplifier coupled to the patient with its output coupled in a forward loop through a first optic coupler to a second operational amplifier. The output of the second operational amplifier is coupled to suitable monitoring circuitry via a feedback circuit including a second optic coupler to the input of the first operational amplifier.
Wireless ultrasound-powered biotelemetry for implants.
Towe, Bruce C; Larson, Patrick J; Gulick, Daniel W
2009-01-01
A miniature piezoelectric receiver coupled to a diode is evaluated as a simple device for wireless transmission of bioelectric events to the body surface. The device converts the energy of a surface-applied ultrasound beam to a high frequency carrier current in solution. Bioelectrical currents near the implant modulate the carrier amplitude, and this signal is remotely detected and demodulated to recover the biopotential waveform. This technique achieves millivolt sensitivity in saline tank tests, and further attention to system design is expected to improve sensitivity.
Kalathil, Shafeer; Lee, Jintae; Cho, Moo Hwan
2013-02-01
Oppan quantized style: By adding a gold precursor at its cathode, a microbial fuel cell (MFC) is demonstrated to form gold nanoparticles that can be used to simultaneously produce bioelectricity and hydrogen. By exploiting the quantized capacitance charging effect, the gold nanoparticles mediate the production of hydrogen without requiring an external power supply, while the MFC produces a stable power density. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Boronoyev, A. B.
1980-01-01
The method of constructing fields on the basis of EEG data gives a quantitative characterization of bioelectrical activity. Fields of average rates of the change of potentials in healthy people have a well defined configuration, where the greatest rates are found in the occipital zones, lower in the frontal and parietal, and least in the temporal zones. In response to functional loads the form of the field remains the same because of a synchronous change in the average rates in both hemispheres of the cerebrum to the same extent. The configuration of the fields of background bioelectric activity of the cerebrum in people with Meniere's disease is not uniform. On the basis of this investigation, a clear correlation was found between the subjective sensations of patients during oxygen and carbogen therapy and the changes in the spatial characteristics of the field of potentials of the cerebrum. This correlation makes it possible to objectively identify the nature of the vascular disturbances in Meniere's disease, develop a pathogenetic treatment plan, and evaluate its effectiveness.
Zietek, Jerzy; Sikora, Jerzy; Horoba, Krzysztof; Matonia, Adam; Jezewski, Janusz; Magnucki, Jacek; Kobielska, Lucyna
2009-03-01
To record and analyse bioelectrical activity of the uterine muscle in the course of physiological pregnancy, labour and threatening premature labour; to define which parameters from the analysis of both electrohysterogram and mechanical activity signal allow us to predict threatening premature labour. Material comprised 62 pregnant women: Group I--27 patients in their first physiological pregnancy, Group II--21 patients in their first pregnancy with symptoms of threatening premature labour, and Group III--14 patients in the first labour period. The on-line analysis of the mechanical (TOCO) and electrical (EHG) contraction activity relied on determination of quantitative parameters of detected uterine contractions. The obtained statistical results demonstrated a possibility to differentiate between Group I and II through the amplitude and contraction area for EHG signal, and only the contraction amplitude for TOCO signal. Additionally, significant differentiating parameters for electrohysterogram are: contraction power and its median frequency. Analyzing Group I and III, significant differences were noted for contraction amplitude and area obtained both from EHG and TOCO signals. Similarly, the contraction power (from EHG) enables us to assign the contractions either to records from Group I or to labour type. There was no significant difference noted between Group II and III. Identification of pregnant women at risk of premature labour should lead to their inclusion in rigorous perinatal surveillance. This requires novel, more sensitive methods that are able to detect early symptoms of the uterine contraction activity increase. Electrohysterography provides complete information on principles of bioelectrical uterine activity. Quantitative parameters of EHG analysis enable the detection of records (contractions) with the symptoms of premature uterine contraction activity.
Mikisková, Hana; Mikiska, Aloš
1968-01-01
Four electrophysiological methods, two based on stimulation (measurement of spinal reflex excitability and of direct excitability of the cerebral motor cortex) and two based on bioelectric recording (electro-encephalography and electrocardiography), were used in intact guinea-pigs and rabbits for studying the action of narcotic and anaesthetic agents, especially of industrial solvents. The authors' results have been reviewed and compared with those of other investigators in an attempt to work out experimental procedures for routine toxicity testing. PMID:4296739
Martin, G; Baumann, H; Grieger, F
1976-01-01
Using the average evoked potential technique, angiotensin-II depot effects (1 mg implantate = 3--4 mg/kg body weight angiotensin-II) were studied neuroelectrophysiologically in reticular, hippocampal and neocrotical structures of albino rats. A multivariate variance and discriminance analysis program revealed differentiated changes of the bioelectrical processing data of the CNS. Evidence was obtained for a varying structural sensitivity of central-nervous substructures under depot administration of angiotensin-II. In later phases of angiotensin-II action, the hippocampus was characterized by an electrographic synchronization phenomenon with high-amplitude average evoked potentials. The reticular formation, and to a lesser extent the visual cortex, showed an angiotensin-induced diminution of bioelectrical excitation. However, the intensity of the change in functional CNS patterns did not always correlate with maximal blood pressure rises. The described changes of afference processing to standardized sensory stimuli, especially in hippocampal and reticular structures of the CNS foll owing angiotensin depot action, point to a central-nervous action mechanism of angiotensin-II.
Yang, Meng; Zhong, Yuezhi; Zhang, Baogang; Shi, Jiaxin; Huang, Xueyang; Xing, Yi; Su, Lin; Liu, Huipeng; Borthwick, Alistair G L
2018-01-31
Anode materials and structures are of critical importance for microbial fuel cells (MFCs) recovering energy from toxic substrates. Carbon-fiber-felt anodes modified by layers of vertically oriented TiO 2 and Fe 2 O 3 nanosheets were applied in the present study. Enhanced sulfide removal efficiencies (both over 90%) were obtained after a 48-h operation, with maximum power densities improved by 1.53 and 1.36 folds compared with MFCs with raw carbon-fiber-felt anode. The modified anodes provided more active sites for microbial adhesion with increasing biomass densities. High-throughput 16S rRNA gene sequencing analysis also indicated the increase in microbial diversities. Bacteroidetes responsible for bioelectricity generation with Thiobacillus and Spirochaeta dominating sulfide removal were found in the MFCs with the modified anodes, with less anaerobic fermentative bacteria as Firmicutes appeared. This indicates that the proposed materials are competitive for applications of MFCs generating bioelectricity from toxic sulfide.
Early bioelectric activities mediate redox-modulated regeneration
Ferreira, Fernando; Luxardi, Guillaume; Reid, Brian
2016-01-01
Reactive oxygen species (ROS) and electric currents modulate regeneration; however, the interplay between biochemical and biophysical signals during regeneration remains poorly understood. We investigate the interactions between redox and bioelectric activities during tail regeneration in Xenopus laevis tadpoles. We show that inhibition of NADPH oxidase-mediated production of ROS, or scavenging or blocking their diffusion into cells, impairs regeneration and consistently regulates the dynamics of membrane potential, transepithelial potential (TEP) and electric current densities (JI) during regeneration. Depletion of ROS mimics the altered TEP and JI observed in the non-regenerative refractory period. Short-term application of hydrogen peroxide (H2O2) rescues (from depleted ROS) and induces (from the refractory period) regeneration, TEP increase and JI reversal. H2O2 is therefore necessary for and sufficient to induce regeneration and to regulate TEP and JI. Epistasis assays show that voltage-gated Na+ channels act downstream of H2O2 to modulate regeneration. Altogether, these results suggest a novel mechanism for regeneration via redox-bioelectric orchestration. PMID:27827821
The climate impacts of bioenergy systems depend on market and regulatory policy contexts.
Lemoine, Derek M; Plevin, Richard J; Cohn, Avery S; Jones, Andrew D; Brandt, Adam R; Vergara, Sintana E; Kammen, Daniel M
2010-10-01
Biomass can help reduce greenhouse gas (GHG) emissions by displacing petroleum in the transportation sector, by displacing fossil-based electricity, and by sequestering atmospheric carbon. Which use mitigates the most emissions depends on market and regulatory contexts outside the scope of attributional life cycle assessments. We show that bioelectricity's advantage over liquid biofuels depends on the GHG intensity of the electricity displaced. Bioelectricity that displaces coal-fired electricity could reduce GHG emissions, but bioelectricity that displaces wind electricity could increase GHG emissions. The electricity displaced depends upon existing infrastructure and policies affecting the electric grid. These findings demonstrate how model assumptions about whether the vehicle fleet and bioenergy use are fixed or free parameters constrain the policy questions an analysis can inform. Our bioenergy life cycle assessment can inform questions about a bioenergy mandate's optimal allocation between liquid fuels and electricity generation, but questions about the optimal level of bioenergy use require analyses with different assumptions about fixed and free parameters.
A Comparative Study of Four Impedance Eduction Methodologies Using Several Test Liners
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.
2013-01-01
A comparative study of four commonly used impedance eduction methods is presented for a range of liner structures and test conditions. Two of the methods are restricted to uniform flow while the other two accommodate both uniform and boundary layer flows. Measurements on five liner structures (a rigid-wall insert, a ceramic tubular liner, a wire mesh liner, a low porosity conventional liner, and a high porosity conventional liner) are obtained using the NASA Langley Grazing Flow Impedance Tube. The educed impedance of each liner is presented for forty-two test conditions (three Mach numbers and fourteen frequencies). In addition, the effects of moving the acoustic source from upstream to downstream and the refractive effects of the mean boundary layer on the wire mesh liner are investigated. The primary conclusions of the study are that: (1) more accurate results are obtained for the upstream source, (2) the uniform flow methods produce nearly identical impedance spectra at and below Mach 0.3 but significant scatter in the educed impedance occurs at the higher Mach number, (3) there is better agreement in educed impedance among the methods for the conventional liners than for the rigid-wall insert, ceramic, or wire mesh liner, and (4) the refractive effects of the mean boundary layer on the educed impedance of the wire mesh liner are generally small except at Mach 0.5.
NASA Astrophysics Data System (ADS)
Aleksanyan, Grayr; Shcherbakov, Ivan; Kucher, Artem; Sulyz, Andrew
2018-04-01
With continuous monitoring of the lungs using multi-angle electric impedance tomography method, a large array of images of impedance changes in the patient's chest cavity is accumulated. This article proposes a method for evaluating the regional ventilation function of lungs based on the results of continuous monitoring using the multi-angle electric impedance tomography method, which allows one image of the thoracic cavity to be formed on the basis of a large array of images of the impedance change in the patient's chest cavity. In the presence of pathologies in the lungs (neoplasms, fluid, pneumothorax, etc.) in these areas, air filling will be disrupted, which will be displayed on the generated image. When conducting continuous monitoring in several sections, a three-dimensional pattern of air filling of the thoracic cavity is possible.
Levin, Michael
2013-01-01
Transformative impact in regenerative medicine requires more than the reprogramming of individual cells: advances in repair strategies for birth defects or injuries, tumor normalization, and the construction of bioengineered organs and tissues all require the ability to control large-scale anatomical shape. Much recent work has focused on the transcriptional and biochemical regulation of cell behaviour and morphogenesis. However, exciting new data reveal that bioelectrical properties of cells and their microenvironment exert a profound influence on cell differentiation, proliferation, and migration. Ion channels and pumps expressed in all cells, not just excitable nerve and muscle, establish resting potentials that vary across tissues and change with significant developmental events. Most importantly, the spatio-temporal gradients of these endogenous transmembrane voltage potentials (Vmem) serve as instructive patterning cues for large-scale anatomy, providing organ identity, positional information, and prepattern template cues for morphogenesis. New genetic and pharmacological techniques for molecular modulation of bioelectric gradients in vivo have revealed the ability to initiate complex organogenesis, change tissue identity, and trigger regeneration of whole vertebrate appendages. A large segment of the spatial information processing that orchestrates individual cells’ programs towards the anatomical needs of the host organism is electrical; this blurs the line between memory and decision-making in neural networks and morphogenesis in non-neural tissues. Advances in cracking this bioelectric code will enable the rational reprogramming of shape in whole tissues and organs, revolutionizing regenerative medicine, developmental biology, and synthetic bioengineering. PMID:23897652
Liu, Jinmeng; Wang, Xinhua; Wang, Zhiwei; Lu, Yuqin; Li, Xiufen; Ren, Yueping
2017-03-01
Microbial fuel cells (MFCs) and forward osmosis (FO) are two emerging technologies with great potential for energy-efficient wastewater treatment. In this study, anaerobic acidification and FO membrane were simultaneously integrated into an air-cathode MFC (AAFO-MFC) for enhancing bio-electricity and water recovery from low-strength wastewater. During a long-term operation of approximately 40 days, the AAFO-MFC system achieved a continuous and relatively stable power generation, and the maximum power density reached 4.38 W/m 3 . The higher bio-electricity production in the AAFO-MFC system was mainly due to the accumulation of ethanol resulted from anaerobic acidification process and the rejection of FO membrane. In addition, a proper salinity environment in the system controlled by the addition of MF membrane enhanced the electricity production. Furthermore, the AAFO-MFC system produced a high quality effluent, with the removal rates of organic matters and total phosphorus of more than 97%. However, the nitrogen removal was limited for the lower rejection of FO membrane. The combined biofouling and inorganic fouling were responsible for the lower water flux of FO membrane, and the Desulfuromonas sp. utilized the ethanol for bio-electricity production was observed in the anode. These results substantially improve the prospects for simultaneous wastewater treatment and energy recovery, and further studies are needed to optimize the system integration and operating parameters. Copyright © 2016 Elsevier Ltd. All rights reserved.