Sample records for bioenterics intragastric balloon

  1. Does the intragastric balloon have a predictive role in subsequent LAP-BAND(®) surgery? Italian multicenter study results at 5-year follow-up.

    PubMed

    Genco, Alfredo; Lorenzo, Michele; Baglio, Giovanni; Furbetta, Francesco; Rossi, Angelo; Lucchese, Marcello; Zappa, Marco A; Giardiello, Cristiano; Micheletto, Giancarlo; Bottari, Giorgio; Puglisi, Francesco; Montanari, Luca; Simona, Civitelli; Forestieri, Pietro

    2014-01-01

    The intragastric balloon has been reported to be a safe and effective tool for temporary weight loss. The aim of this study is the evaluation of the possible predictive role of intragastric balloon when used before laparoscopic adjustable gastric banding. A longitudinal multicenter study was conducted in patients with body mass index (BMI)>35 kg/m(2) who underwent gastric banding with the BioEnterics Intragastric Balloon (BIB). After balloon removal (6 mo), patients were allocated into 2 group according to their percentage of excess weight loss (%EWL): group>25 (%EWL>25%) and group<25 (%EWL<25%). Patients from both group underwent laparoscopic adjustable gastric banding (LAGB) 1-3 months after BIB removal. The LAP-BAND AP band was placed in all patients via pars flaccida. Weight loss parameters were considered in both groups. From January 2005 to December 2009, 1357 patients were enrolled in this study. Mean BMI at time of BIB positioning was 44.9±8.4 (range 29-82.5). After 6 months, at time of removal, mean BMI was 39.4±7.3. According to the cutoff, patients were allocated into group A (n = 699) and group B (n = 658). At this time the mean BMI was 36.4±6.4 and 42.7±6.9 (P = .001) in groups A and B, respectively. At 1-year follow-up from LAGB, mean BMI was 35.8±6.5 and 40.0±7.4 (P<.001) in groups A and B, respectively. This significant difference was confirmed at 3- and 5-year follow-ups. A similar pattern was observed with the %EWL. Satisfactory results with BIB are predictive of a positive outcome of LASB at 1, 3, and 5 years after the procedure, and poor results do not inevitably indicate a negative outcome for gastric banding. Copyright © 2014 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  2. [Benefit from bio-enteric Intra-gastric balloon (BIB) to modify lifestyle and eating habits in severely obese patients eligible for bariatric surgery].

    PubMed

    Zago, S; Kornmuller, A M; Agagliati, D; Saber, B; Ferrari, D; Maffeis, P; Labate, M; Bauducco, E; Manghisi, L; Martignone, L; Spanu, M; Rovera, G M

    2006-02-01

    The therapeutic model for severe obesity includes bariatric surgery, representing the safest way to keep weight down and to prevent relapses. The selection of patients for the most suitable type of surgery implies multidisciplinary approach (nutritionist, dietist, clinical psychologist and surgeon). The intragastric balloon may represent a relatively invasive method to help the medical team to select and prepare severely obese patients for restrictive bariatric surgery. In our study we considered 48 severely obese patients: initial weight 111+/-14.8 kg, BMI 43+/-5.02, excess weight 77.47+/-16.14%. These patients have been treated with intragastric balloon (BIB) filled to a volume of 500 cc for 6 months. We considered variations induced by BIB treatment on a number of parameters--clinical, anthropometric, food intake, partition of nourishing elements and psychological and psychometric data. At the end of the treatment the patients showed significant reductions of excess weight (67.35+/-20.19%), of weight (103.4+/-16.72 kg) and food intake, without modification of the items in the EDI2 test, but with important motivational support for a change in life style between the beginning and the end of the treatment, clearly resulting from the medical, dietist and clinical-psychological follow-up. BIB is a relatively invasive means capable of modifying eating habits in the short term; it induces weight loss, may help to reduce the anaesthesiological risk and to foster a change in the patient's behaviour. In our experience treatment with BIB is useful from the educational point of view and can be used to select patients for bariatric surgery only within a multidisciplinary team. Further clinical studies are necessary.

  3. Gastric emptying and intragastric balloon in obese patients.

    PubMed

    Bonazzi, P; Petrelli, M D; Lorenzini, I; Peruzzi, E; Nicolai, A; Galeazzi, R

    2005-01-01

    Intragastric balloons have been proposed to induce weight loss in obese subjects. The consequences of the balloon on gastric physiology remain poorly studied. We studied the influence of an intragastric balloon on gastric emptying in obese patients. 12 patients were included in the study, with BMI (mean +/- SD) of 38.51 +/- 4.32 kg/m2. The balloon was inserted under light anaesthesia and endoscopic control, inflated with 700 ml saline, and removed 6 months later. Body weight and gastric emptying (T1/2 and T lag) using 13C-octanoic acid breath test were monitored before balloon placement, during its permanence and 2 months after removal. Mean weight loss was: 6.2 +/- 2.3 kg after one month; 12.4 +/- 5.8 kg after 3 months; 14.4 +/- 6.6 kg after 6 months and 10.1 +/- 4.3 kg two months after BIB removal. Gastric emptying rates were significantly decreased in the first periods with balloon in place, and returned to pre-implantation values after balloon removal. T1/2 was: 87 +/- 32 min before BIB positioning, 181 +/- 91 min after 1 month, 145 +/- 99 min after 3 months, 104 +/- 50 min after 6 months and 90 +/- 43 min 2 months after removal. T lag was 36 +/- 18 min before BIB positioning, 102 +/- 82 min after 1 month, 77 +/- 53 min after 3 months, 59 +/- 28 min after 6 months and 40 +/- 21 min. 2 months after removal. BIB in obese patients seems to be a good help in following the hypo caloric diet, especially during the first three months when the gastric emptying is slower and the sense of repletion is higher. After this period gastric emptying starts to return to normal and the stomach adapts to BIB loosing efficacy in weight loss.

  4. Gastric Ulcer Hemorrhage - a Potential Life-Threatening Complication of Intragastric Balloon Treatment of Obesity.

    PubMed

    Mojkowska, Aleksandra; Gazdzinski, Stefan; Fraczek, Mariusz; Wyleżoł, Mariusz

    2017-01-01

    Some morbidly obese patients do not qualify for bariatric surgery due to general health contraindications. Intragastric balloon treatment might be a therapeutic option in the above-mentioned cases. It can prime super-obese patients with end-stage disease for bariatric surgery. As a neoadjuvant therapy before surgery, it leads to a downstage of the disease by preliminary weight reduction, to an improvement in general health and, in summary, to a reduction of the perioperative risk. It is generally considered to be a safe method. However, due to the wide range of possible complications and unusual symptoms after intragastric balloon treatment, an interdisciplinary, instead of only a surgical or endoscopic, treatment and follow-up might be recommended in these patients. We here describe a potential life-threatening complication in the form of gastric bleeding as a consequence of intragastric balloon treatment and simultaneous aspirin taking and Helicobacter pylori infection. There have been reports of some complications of intragastric balloon treatment. However, to the best of our knowledge there were no reports concerning life-threatening hemorrhage from gastric ulcer. © 2017 The Author(s) Published by S. Karger GmbH, Freiburg.

  5. Gastric Ulceration and Bleeding with Hemodynamic Instability Caused by an Intragastric Balloon for Weight Loss.

    PubMed

    Reed, Larrite; Edriss, Hawa; Nugent, Kenneth

    2018-06-01

    Obesity in the United States is a medical crisis with many people attempting to lose weight with caloric restriction. Some patients choose minimally invasive weight loss solutions, such as intragastric balloon systems. These balloon systems were approved by the Federal Drug Administration (FDA) in 2015-2016 and have been considered safe, with minimal side effects. We report a patient with a two-day history of melena, abdominal pain, hypotension, and syncope which developed five months after placement of an intragastric balloon. Esophagogastroduodenoscopy with balloon removal revealed a small 8-mm gastric ulcer in the incisura. This gastric ulcer probably developed secondary to mechanical compression of the stomach mucosa by the gastric balloon which contained 900 mL of saline. The FDA is now investigating five deaths since 2016 associated with these second-generation balloons. Clinicians should be aware of these complications when evaluating patients with gastrointestinal complications, such as bleeding.

  6. [Adherence and fidelity in patients treated with intragastric balloon].

    PubMed

    Mazure, R A; Cancer, E; Martínez Olmos, M A; De Castro, M L; Abilés, V; Abilés, J; Bretón, I; Álvarez, V; Peláez, N; Culebras, J M

    2014-01-01

    A correct treatment of obesity needs a program of habits modification regardless of the selected technique, especially if it is minimally invasive as the intragastric balloon (BIG). The adherence of the obese patients with regard to recommended drugs measures to medium- and long-term is less than 50%. Given that the results obtained using the technique of gastric balloon must be seen influenced by adherence to the modification of habits program and its fulfillment, we reviewed series published in attention to the program proposed with the BIG. The series published to date provide few details about the used Therapeutic Programs as well as the adherence of patients to them, and even less concerning the Monitoring Plan and the loyalty of the patient can be seen. We conclude the convenience to agree on a follow-up strategy, at least the 6 months during which the BIG remain in the stomach.

  7. Efficacy, tolerance and safety of new intragastric air-filled balloon (Heliosphere BAG) for obesity: the experience of 17 cases.

    PubMed

    Trande, Paolo; Mussetto, Alessandro; Mirante, Vincenzo G; De Martinis, Elvira; Olivetti, Giampiero; Conigliaro, Rita L; De Micheli, Enrico A

    2010-09-01

    Overweight and obesity lead to serious health consequences, so that many strategies were recommended for preventing or curing this emerging problem. Treatments are various: diet, physical activity, psychotherapy, drugs, and bariatric surgery. Moreover, during these years, the use of intragastric balloon (BIB) to treat obesity increased rapidly, aimed to (1) reduce bariatric surgical risks; (2) reduce general surgical risks; (3) lead to a significant reduction in the prevalence of cardiovascular diseases, diabetes, musculoskeletal disorders and some cancers. Recently, a new device inflated with air to reduce weight has been developed since 2004 (Heliosphere BAG). Between March 2006 and September 2006, in our unit, intragastric air-filled balloon insertion was performed under general anesthesia and endoscopic control. The balloons were removed after 6 months. We evaluated efficacy, tolerance, and safety of this technique. Seventeen patients (eight men, nine women), with a mean age of 43 +/- 10 years (range 18-65), mean basal BMI of 46 +/- 8 (range 35-58) were included, after providing informed consent. Weight and BMI loss were evaluated in all patients. BMI decreased 4 +/- 3 (range +0.33/-11), weight loss was 11 +/- 9 kg (range +1/-29.5; 8.5%). 14/17 patients maintain a BMI > 35 at the time of balloon removal. The difference between initial weight and BMI was statistically significant (p = 0.02 for weight and p < 0.01 for BMI, T Student test). Tolerance was very good, limited only to some dyspeptic symptoms during the first 3 days after insertion. One asymptomatic gastric ulcer was seen at the removal of balloon. Only one severe adverse effect was registered at the time of insertion (acute coronary syndrome in patient with chronic coronary disease). No serious technical problems were noted at balloon insertion. Balloon removal was more difficult and successful in 15/17 cases (one distal migration and one patient led to surgery because of balloon fragmentation

  8. The Obalon swallowable intragastric balloon in pediatric and adolescent morbid obesity

    PubMed Central

    De Peppo, Francesco; Caccamo, Romina; Adorisio, Ottavio; Ceriati, Emanuela; Marchetti, Paola; Contursi, Antonio; Alterio, Arianna; Della Corte, Claudia; Manco, Malnia; Nobili, Valerio

    2017-01-01

    Background and study aims Incidence of morbid obesity has grown dramatically in the last half century and this phenomenon affects with particular severity the pediatric population. Dietary restrictions and careful programs to improve lifestyle are often ineffective to manage this particular group of patients, due to poor compliance typical of the adolescence. The aim of this study was to evaluate the effectiveness of a new intragastric balloon for treatment of morbidly obese children. Patients and methods A new swallowable intragastric balloon (Obalon) has been used for the first time in 17 obese children in order to assess its safety and effectiveness in terms of reduction in excess weight. In 9 of 17 children a second balloon was placed 30 to 40 days after the first insertion. All devices were endoscopically removed after a mean time of 18 weeks. Results In the group of 16 patients who completed the study (1 patient still under treatment) mean weight decreased from 95.8 ± 18.4 Kg to 83.6 ± 27.1 (P < 0.05). Mean body mass index (BMI) decreased from 35.27± 5.89 (range 30.4 – 48) to 32.25 ± 7.1 (range 23.5 – 45.7) (P > 0.05); mean excess weight, calculated according to Cole’s curves for pediatric populations, decreased from 36.2 ± 15.9 to 29.4 ± 18.3 Kg (P = 0.14), with an %EWL of 20.1 ± 9.8 (range 2.3 – 35.1). Waist circumference decreased from 109 ± 12.3 cm to 99 ± 10.5 cm (P < 0.05). Conclusions Obalon can be administered easily without complications, inducing an appreciable weight loss with a statistically significant reduction in BMI and an improvement in associated comorbidities. PMID:28180149

  9. Fasting and meal-induced CCK and PP secretion following intragastric balloon treatment for obesity.

    PubMed

    Mathus-Vliegen, Elisabeth M H; de Groot, Gerrit H

    2013-05-01

    Satiety is centrally and peripherally mediated by gastrointestinal peptides and the vagal nerve. We aimed to investigate whether intragastric balloon treatment affects satiety through effects on fasting and meal-stimulated cholecystokinin (CCK) and pancreatic polypeptide (PP) secretion. Patients referred for obesity treatment were randomised to 13 weeks of sham treatment followed by 13 weeks of balloon treatment (group 1; sham/balloon) or to twice a 13-week period of balloon treatment (group 2; balloon/balloon). Blood samples were taken for fasting and meal-stimulated CCK and PP levels at the start (T0) and after 13 (T1) and 26 (T2) weeks. Patients filled out visual analogue scales (VAS) to assess satiety. Forty-two patients (35 females, body weight 125.1 kg, BMI 43.3 kg/m(2)) participated. In group 1, basal CCK levels decreased but meal-stimulated response remained unchanged after 13 weeks of sham treatment. In group 2, basal and meal-stimulated CCK levels decreased after 13 weeks of balloon treatment. At the end of the second 13-week period, when group 1 had their first balloon treatment, they duplicated the initial 13-week results of group 2, whereas group 2 continued their balloon treatment and reduced meal-stimulated CCK release. Both groups showed reduced meal-stimulated PP secretions at T1 and T2 compared to T0. Changes in diet composition and VAS scores were similar. Improvements in glucose homeostasis partly explained the PP results. The reduced CCK and PP secretion after balloon positioning was unexpected and may reflect delayed gastric emptying induced by the balloon. Improved glucose metabolism partly explained the reduced PP secretion. Satiety and weight loss were not adversely influenced by these hormonal changes.

  10. Intragastric Balloon Treatment for Obesity: Review of Recent Studies.

    PubMed

    Tate, Chinara M; Geliebter, Allan

    2017-08-01

    The FDA recently approved three intragastric balloon (IGB) devices, ReShape, ORBERA™, and Obalon for treatment of obesity. Given the high cost, complication risk, and invasiveness of bariatric surgery, IGB treatment may present a safer and lower cost option for weight reduction. IGBs are generally placed in the stomach endoscopically for up to 6 months to reduce gastric capacity, enhance feelings of fullness, and induce weight loss. The mechanism of action likely involves stimulation of gastric mechanoreceptors triggering short-acting vagal signals to brain regions implicated in satiety. Balloon efficacy may be influenced by balloon volume, patient gastric capacity, and treatment duration. This review focused on eight recent (2006-present) randomized controlled trials (RCTs) comparing percentage total body weight loss (%TBWL) between IGB and control groups including three reviewed by the FDA. %TBWL based on the reviewed studies was also compared with bariatric surgery and pharmacotherapy. Of the eight IGB studies, five had balloon treatment duration of 6 months. Efficacy at 6 months, based on a pooled weighted-mean %TBWL, was 9.7%, and the control-subtracted %TBWL was 5.6%. When one study without SDs was removed, the weighted mean %TBWL was 9.3 ± 5.7% SD, and control-subtracted %TBWL was 5.5 ± 7.8%, which was statistically greater than controls. IGB showed lower efficacy than bariatric surgery (median weight loss of 27% for Rouen-Y gastric bypass (RYGB). The control-subtracted %TBWL over 6 months of 5.5-5.6% is less than the most efficacious FDA-approved weight loss drug, Qsymia. At the recommended dose, Qsymia has a placebo-subtracted %TBWL at 6 months of approximately 6.6%. The weighted mean reported incidence of serious adverse events (SAEs) in the IGB group across all eight studies was 10.5%. Only six of the eight reviewed studies reported adverse events (AEs) in the IGB group, with a pooled reported incidence of 28.2%. Recently, the FDA reported new

  11. Gastric wall changes after intragastric balloon placement: a preliminary experience.

    PubMed

    Périssé, Luís Gustavo Santos; Ecbc-Rj, Paulo Cézar Marques Périssé; Ribeiro, Kelson Ferreira

    2016-01-01

    : to evaluate the thickness of the gastric wall at the time of intra gastric balloon (IGB) placement, at the time of its withdrawal and one month after withdrawal. : fifteen morbidly obese patients underwent the introduction of IGB under general anesthesia. In all patients, there was infusion of 500ml of distilled water in the balloon for the test. Measurements of the thickness of the gastric wall were made in the antrum, body and proximal body, using a radial echoendoscope with a frequency of 12MHz and maximum zoom, and its own balloon inflated with 5ml of distilled water. : the presence of IGB led to increased wall thickness of the gastric body by expanding the muscle layer. These changes were apparently transient, since 30 days after the balloon withdrawal there was a tendency to return of the wall thickness values ​​observed before the balloon insertion. : the use of intragastric balloon for the treatment of obesity determines transient increase in the wall thickness of the gastric body caused by expanded muscle layer. avaliar a espessura da parede gástrica no momento do posicionamento do balão intragástrico (BIG), no momento de sua retirada e um mês após a retirada. quinze pacientes obesos mórbidos foram submetidos à introdução de BIG sob anestesia geral. Em todos os pacientes foi feita infusão de 500 ml de água destilada e o balão foi insuflado com 5ml de água destilada. As medidas da espessura da parede gástrica foram feitas no antro, corpo e corpo alto utilizando-se um ecoendoscópio radial com frequência de 12MHz e zoom máximo. a presença do BIG levou ao aumento da espessura da parede do corpo gástrico pelo aumento de espessura da sua camada muscular. Estas alterações são aparentemente transitórias já que após 30 dias da retirada do balão existiu uma tendência de retorno da espessura da parede aos valores observados antes do seu posicionamento. a utilização do balão intragástrico para tratamento da obesidade determina

  12. Single Fluid-Filled Intragastric Balloon Safe and Effective for Inducing Weight Loss in a Real-World Population.

    PubMed

    Vargas, Eric J; Pesta, Carl M; Bali, Ahmad; Ibegbu, Eric; Bazerbachi, Fateh; Moore, Rachel L; Kumbhari, Vivek; Sharaiha, Reem Z; Curry, Trace W; DosSantos, Gina; Schmitz, Ramsey; Agnihotri, Abhishek; Novikov, Aleksey A; Pitt, Tracy; Dunlap, Margo K; Herr, Andrea; Aronne, Louis; Ledonne, Erin; Kadouh, Hoda C; Cheskin, Lawrence J; Mundi, Manpreet S; Acosta, Andres; Gostout, Christopher J; Abu Dayyeh, Barham K

    2018-07-01

    The Orbera intragastric balloon (OIB) is a single fluid-filled intragastric balloon approved for the induction of weight loss and treatment of obesity. However, little is known about the effectiveness and safety of the OIB outside clinical trials, and since approval, the Food and Drug Administration has issued warnings to health care providers about risk of balloon hyperinflation requiring early removal, pancreatitis, and death. We analyzed data on patients who have received the OIB since its approval to determine its safety, effectiveness, and tolerance in real-world clinical settings. We performed a postregulatory approval study of the safety and efficacy of the OIB, and factors associated with intolerance and response. We collected data from the Mayo Clinic's database of patient demographics, outcomes of OIB placement (weight loss, weight-related comorbidities), technical aspects of insertion and removal, and adverse events associated with the device and/or procedure, from 8 centers (3 academic, 5 private, 4 surgeons, and 4 gastroenterologists). Our final analysis comprised 321 patients (mean age, 48.1 ± 11.9 y; 80% female; baseline body mass index, 37.6 ± 6.9). Exploratory multivariable linear and logistic regression analyses were performed to identify predictors of success and early balloon removal. Primary effectiveness outcomes were percentage of total body weight lost at 3, 6, and 9 months. Primary and secondary safety outcomes were rates of early balloon removal, periprocedural complications, dehydration episodes requiring intravenous infusion, balloon migration, balloon deflation or hyperinflation, pancreatitis, or other complications. Four patients had contraindications for placement at the time of endoscopy. The balloon was safely removed in all instances with an early removal rate (before 6 months) in 16.7% of patients, at a median of 8 weeks after placement (range, 1-6 mo). Use of selective serotonin or serotonin-norepinephrine re-uptake inhibitors

  13. The role of endoscopic therapy in obesity management: intragastric balloons and aspiration therapy

    PubMed Central

    Kumar, Nitin; Sullivan, Shelby; Thompson, Christopher C

    2017-01-01

    Weight management is increasingly incorporating endoscopic bariatric therapy (EBT). As the global burden of obesity and its comorbidities has increased, it is evident that novel therapeutic approaches will be necessary to address the obesity epidemic. EBTs offer greater efficacy than diet and lifestyle modification and lower invasiveness than bariatric surgery. The US Food and Drug Administration has approved two intragastric balloons and aspiration therapy for the treatment of obesity: Apollo Orbera is indicated for the treatment of Class I and Class II obesity, Re Shape Integrated Dual Balloon system is indicated for the same range with a comorbidity, and Aspire Bariatrics AspireAssist is approved for patients with a body mass index of 35–55 kg/m2. These devices have proven safe and effective in clinical trials and are gaining commercial acceptance in the USA; the Orbera has been used extensively outside the USA for over 20 years. These devices will need to be delivered in the context of a multidisciplinary weight loss program, integrating comprehensive care of obesity. Patient selection is important, and ensuring appropriate patient expectations and understanding of alternatives such as pharmacologic therapy and surgery is essential. With several EBTs on the horizon, patients with obesity will have an even broader array of safe and effective options for weight management in the future. PMID:28740414

  14. The role of endoscopic therapy in obesity management: intragastric balloons and aspiration therapy.

    PubMed

    Kumar, Nitin; Sullivan, Shelby; Thompson, Christopher C

    2017-01-01

    Weight management is increasingly incorporating endoscopic bariatric therapy (EBT). As the global burden of obesity and its comorbidities has increased, it is evident that novel therapeutic approaches will be necessary to address the obesity epidemic. EBTs offer greater efficacy than diet and lifestyle modification and lower invasiveness than bariatric surgery. The US Food and Drug Administration has approved two intragastric balloons and aspiration therapy for the treatment of obesity: Apollo Orbera is indicated for the treatment of Class I and Class II obesity, Re Shape Integrated Dual Balloon system is indicated for the same range with a comorbidity, and Aspire Bariatrics AspireAssist is approved for patients with a body mass index of 35-55 kg/m 2 . These devices have proven safe and effective in clinical trials and are gaining commercial acceptance in the USA; the Orbera has been used extensively outside the USA for over 20 years. These devices will need to be delivered in the context of a multidisciplinary weight loss program, integrating comprehensive care of obesity. Patient selection is important, and ensuring appropriate patient expectations and understanding of alternatives such as pharmacologic therapy and surgery is essential. With several EBTs on the horizon, patients with obesity will have an even broader array of safe and effective options for weight management in the future.

  15. Endoscopic therapy for weight loss: Gastroplasty, duodenal sleeves, intragastric balloons, and aspiration

    PubMed Central

    Kumar, Nitin

    2015-01-01

    A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery. PMID:26240686

  16. Endoscopic therapy for weight loss: Gastroplasty, duodenal sleeves, intragastric balloons, and aspiration.

    PubMed

    Kumar, Nitin

    2015-07-25

    A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery.

  17. The Influence of the Orbera Intragastric Balloon Filling Volumes on Weight Loss, Tolerability, and Adverse Events: a Systematic Review and Meta-Analysis.

    PubMed

    Kumar, Nitin; Bazerbachi, Fateh; Rustagi, Tarun; McCarty, Thomas R; Thompson, Christopher C; Galvao Neto, Manoel P; Zundel, Natan; Wilson, Erik B; Gostout, Christopher J; Abu Dayyeh, Barham K

    2017-09-01

    The Orbera intragastric balloon (IGB) has been approved by the US Food and Drug Administration for use in patients with a body mass index (BMI) between 30 and 40 kg/m 2 and is in wide use worldwide as a primary and bridge obesity management tool. The balloon filling volume (BFV) ranges between 400 and 700 mL of saline. Our objective was to determine whether there is an association between BFV and clinically relevant endpoints, namely weight loss outcomes, balloon tolerability, and adverse events. A systematic review of studies investigating the use of the Orbera IGB system for obesity treatment was performed. Data was examined using random effects modelling and meta-regression analyses. Forty-four studies (n = 5549 patients) reported BFV and % total body weight loss (TBWL) at 6 months. Pooled %TBWL at 6 months was 13.2% [95% CI 12.3-14.0]. A funnel plot demonstrated a low risk of publication bias. Meta-regression showed no statistically significant association between filling volume and %TBWL at 6 months (p = 0.268). Higher BFV was associated with lower rates of esophagitis (slope = -0.008, p < 0.001) and prosthesis migration (slope = -0.015, p < 0.001). There was no association between BFV and early removal (p = 0.1), gastroesophageal reflux symptom (p = 0.64), or ulcer rates (p = 0.09). No association was observed between Orbera IGB filling volume and weight loss outcomes. Higher volumes appear to be associated with lower migration and esophagitis rates; thus, a balloon filling volume of 600-650 mL is recommended.

  18. Circulating SIRT1 Increases After Intragastric Balloon Fat Loss in Obese Patients.

    PubMed

    Mariani, Stefania; Fiore, Daniela; Persichetti, Agnese; Basciani, Sabrina; Lubrano, Carla; Poggiogalle, Eleonora; Genco, Alfredo; Donini, Lorenzo Maria; Gnessi, Lucio

    2016-06-01

    Sirtuins (SIRTs), ubiquitous deacetylases, are main regulators of energy homeostasis and metabolism. SIRT1 has a positive impact on obesity, diabetes mellitus, liver steatosis, and other metabolic disorders. Lean subjects have higher expression of SIRT1 in the adipose tissue compared to obese. However, it is not known whether weight loss associates with changes in blood SIRT1. We evaluated the effect of weight loss on circulating SIRT1, metabolic parameters, and body composition. Thirty-two obese subjects were studied before and 6 months after BioEnterics® Intragastric Balloon (BIB®) [22 patients, BMI 41.82 ± 6.28 kg/m(2)] or hypocaloric diet [10 patients, BMI 38.95 ± 6.90 kg/m(2)]. Plasma SIRT1, body composition, measures of metabolic syndrome (waist circumference, fasting plasma glucose, blood pressure, HDL cholesterol, triglycerides), and inflammation markers (ESR, CRP, fibrinogen) were recorded. SIRT1 levels showed a significant increase, together with a significant reduction of BMI, excess body weight, and total fat mass either after BIB or diet intervention. The percent excess body weight loss was 33.73 ± 19.06 and 22.08 ± 11.62 % after BIB and diet, respectively, a trend toward a metabolic and inflammatory amelioration was observed with both treatments. Negative correlation between SIRT1 and % fat mass (BIB, ρ = -0.537, p = 0.017; diet, ρ = -0.638, p = 0.047) was also seen. The reduction of fat mass associates with increased plasma SIRT1 indicating that, besides tissue levels, circulating SIRT1 is stimulated by a negative caloric balance. The rise of plasma SIRT1 may represent a parameter associating with fat loss rather than weight lowering regardless of the weight reduction system method used.

  19. Efficacy of intragastric balloon in obese Egyptian patients and the value of extended liquid diet period in mounting the weight loss.

    PubMed

    Abdel-Salam, Wael Nabil; Bekheit, Mohamed; Katri, Khaled; Ezzat, Tarek; El Kayal, El Said

    2013-03-01

    Abstract Background: The surgical management of morbid obesity is faced by several challenges. Alternative therapeutic strategies could have an important role in the perioperative risk reduction. The BioEnterics(®) intragastric balloon (BIB) (Inamed Health, Santa Barbara, CA) has been described as being effective in weight reduction and is used as a bridge before bariatric surgery. This study examined the efficacy of BIB in obese Egyptian patients and the value of the extended low caloric liquid diet program in weight loss. A retrospective review of a prospectively maintained bariatric database was conducted. Weight changes and complications data were analyzed. Indications for BIB placement were discussed. Records of 55 patients (11 males and 44 females) were retrieved. The mean initial body mass index (BMI) was 45.3±11 kg/m(2). The mean of excess body weight percentage was 111.96±53.2%. Nausea was reported in 30 patients (54.5%). Epigastric discomfort was reported in 23 patients (41.8 %), and vomiting was reported in 27 patients (49.1%). Six patients (10.9%) had an early removal of the balloon, whereas 4 (7.2%) had delayed removal (more than 6 months). The mean excess weight loss percentage (EWL%) was 17.2%. There was significant reduction in patients' BMI from 45.3 to 38.3 kg/m(2) (P<.001). There was no significant correlation between the EWL% and the gender, age, or initial BMI. Two patients had second balloon insertions without complications. There was no significant difference in the EWL% between the 1-week liquid diet group and the extended (4-week) low caloric diet group. The BIB is effective and safe in weight reduction in obese Egyptian patients. The impact of extended liquid dieting period is not significant.

  20. Impact of Weight Loss With Intragastric Balloon on Bone Density and Microstructure in Obese Adults.

    PubMed

    Madeira, Eduardo; Madeira, Miguel; Guedes, Erika Paniago; Mafort, Thiago Thomaz; Moreira, Rodrigo Oliveira; de Mendonça, Laura Maria Carvalho; Lima, Inayá Correa Barbosa; Neto, Leonardo Vieira; de Pinho, Paulo Roberto Alves; Lopes, Agnaldo José; Farias, Maria Lucia Fleiuss

    2018-03-21

    The historical concept that obesity protects against bone fractures has been questioned. Weight loss appears to reduce bone mineral density (BMD); however, the results in young adults are inconsistent, and data on the effects of weight loss on bone microstructure are limited. This study aimed to evaluate the impact of weight loss using an intragastric balloon (IGB) on bone density and microstructure. Forty obese patients with metabolic syndrome (mean age 35.1 ± 7.3 yr) used an IGB continuously for 6 mo. Laboratory tests, areal BMD, and body composition measurements via dual-energy X-ray absorptiometry, and volumetric BMD and bone microstructure measurements via high-resolution peripheral quantitative computed tomography were conducted before IGB placement and after IGB removal. The mean weight loss was 11.5%. After 6 mo, there were significant increases in vitamin D and carboxyterminal telopeptide of type 1 collagen levels. After IGB use, areal BMD increased in the spine but decreased in the total femur and the 33% radius. Cortical BMD increased in the distal radius but tended to decrease in the distal tibia. The observed trabecular bone loss in the distal tibia contributed to the decline in the total volumetric BMD at this site. There was a negative correlation between the changes in leptin levels and the measures of trabecular quality in the tibia on high-resolution peripheral quantitative computed tomography. Weight loss may negatively impact bone microstructure in young patients, especially for weight-bearing bones, in which obesity has a more prominent effect. Copyright © 2018 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  1. Advances in endoscopic balloon therapy for weight loss and its limitations

    PubMed Central

    Vyas, Dinesh; Deshpande, Kaivalya; Pandya, Yagnik

    2017-01-01

    The field of medical and surgical weight loss is undergoing an explosion of new techniques and devices. A lot of these are geared towards endoscopic approaches rather than the conventional and more invasive laparoscopic or open approach. One such recent advance is the introduction of intrgastric balloons. In this article, we discuss the recently Food and Drug Administration approved following balloons for weight loss: the Orbera™ Intragastric Balloon System (Apollo Endosurgery Inc, Austin, TX, United States), the ReShape® Integrated Dual Balloon System (ReShape Medical, Inc., San Clemente, CA, United States), and the Obalon (Obalon® Therapeutics, Inc.). The individual features of each of these balloons, the method of introduction and removal, and the expected weight loss and possible complications are discussed. This review of the various balloons highlights the innovation in the field of weight loss. PMID:29209122

  2. Acute complications following endoscopic intragastric balloon insertion for treatment of morbid obesity in elderly patients. A single center experience.

    PubMed

    Velotti, Nunzio; Bianco, Paolo; Bocchetti, Alessio; Milone, Marco; Manzolillo, Domenico; Maietta, Paola; Amato, Maurizio; Buonomo, Oreste; Petrella, Giuseppe; Musella, Mario

    2018-04-13

    Obesity is a serious disease, with an increasing incidence also among subjects over 60 years old; surgical management has proven to be the most effective in the production of significant and durable weight loss. Intragastric balloon (IGB) treatment, promotes a reduction of five to nine body mass index (BMI) units in 6 months with an impressive improvement of obesity-associated comorbidities. Two hundred and twenty five patients, 106 men (47.1%) and 119 women (52.9%), were evaluated at our institution to be submitted to a IGB positioning. Of these, 12 patients (8 women and 4 men) were more than 60 years old. For all patients BMI, co-morbidities, weight loss and complications were recorded. Chi-square test was used to evaluate differences in complications rate between elderly and other patients. For the 12 elderly patients, we recorded a mean excess weight loss rate (EWL%) of 31.4. About complications, we recorded 2 severe esophagitis requiring IGB removal and 1 late gastric perforation. A higher complications rate was found in elderly population and the comparison with other patients revealed a significant difference (p<0.001). Our results underline that IGB treatment in elderly patients is safe and effective in terms of weight loss and improvement in comorbidities. IGB can cause complications which, sometimes, can be severe such as esophageal damage and gastric perforation. For the management of complications, we highly recommend a close follow-up in all patients and a deepened instrumental study in every suspect case.

  3. Efficacy of First-Time Intragastric Balloon in Weight Loss: a Systematic Review and Meta-analysis of Randomized Controlled Trials.

    PubMed

    Saber, Alan A; Shoar, Saeed; Almadani, Mahmoud W; Zundel, Natan; Alkuwari, Mohammed J; Bashah, Moataz M; Rosenthal, Raul J

    2017-02-01

    The intragastric balloon (IGB) is an adjunctive treatment for obesity. This meta-analysis aimed to evaluate the efficacy and safety of IGB treatment by reviewing randomized controlled trials (RCTs). A total of 20 RCTs involving 1195 patients were identified. Weight loss results before and after 3 months were analyzed separately. The weight loss results of patients with and without IGB treatment were compared. Our meta-analysis calculated the following significant effect sizes: 1.59 and 1.34 kg/m 2 for overall and 3-month BMI loss, respectively; 14.25 and 11.16 % for overall and >3-month percentage of excess weight loss, respectively; 4.6 and 4.77 kg for overall and 3-month weight loss, respectively; and 2.81, 1.62, and 4.09 % for overall, 3-month, and >3-month percent of weight loss, respectively. A significant effect size was calculated that favored fluid-filled IGBs over air-filled IGBs. Flatulence (8.75 vs. 3.89 %, p = 0.0006), abdominal fullness (6.32 vs. 0.55 %, p = 0.001), abdominal pain (13.86 vs. 7.2 %, p = 0.0001), abdominal discomfort (4.37 vs. 0.55 %, p = 0.006), and gastric ulcer (12.5 vs. 1.2 %, p < 0.0001) were significantly more prevalent among IGB patients than among non-IGB control patients. No mortality was reported from IGB treatment. IGB treatment, in addition to lifestyle modification, is an effective short-term modality for weight loss. However, there is not sufficient evidence confirming its safety or long-term efficacy.

  4. Intra-gastric pressures in neonates receiving bubble CPAP.

    PubMed

    Tyagi, Prashant; Gupta, Neeraj; Jain, Akanksha; Upadhyay, Pramod; Puliyel, Jacob

    2015-02-01

    To study intra-gastric pressures in neonates receiving bubble continuous positive airway pressure (BCPAP) by nasopharyngeal prong. Twenty seven neonates were recruited for the study. BCPAP pressure of 6 cm water was used in all the neonates. A pressure sensor attached to orogastric tube, measured the intra-gastric pressure prior to starting BCPAP and again between 30 and 90 min of BCPAP. The clinical variables like Downe's score, oxygen saturation, venous blood gas pH, pCO(2) and abdominal girth were recorded alongside with pressure readings. BCPAP resulted in improvement (p < 0.05) in parameters of respiratory distress such as Downe's score (DS), oxygen saturation (SpO(2)) and venous blood gas parameters (pH, pCO(2)). There was no statistical significant increase in intra-gastric pressures (p = 0.834). There were no gastrointestinal complications; abdominal distention, necrotising enterocolitis or gastric perforation during the study. Nasopharyngeal BCPAP at 6 cm of water pressure is an effective modality of treating babies with respiratory distress and the present study shows that it is not associated with a significant rise in intra-gastric pressures.

  5. Safety and effectiveness of gastric balloons associated with hypocaloric diet for the treatment of obesity.

    PubMed

    de Castro, Maria Luisa; Morales, Maria Jose; Martínez-Olmos, Miguel A; Pineda, Juan R; Cid, Lucia; Estévez, Pamela; del-Campo, Victor; Rodríguez-Prada, J Ignacio

    2013-10-01

    intragastric balloons provide early satiety and thereby induce short-term weight loss. The aim of this study was to evaluate safety and short and medium-term effectiveness of gastric balloons associated to hypocaloric diet in obesity. from May 2004 to June 2011 91 obese patients, body mass index (BMI) 45.2 +/- 7.2 kg/m2 were prospectively followed after endoscopic implantation of a gastric balloon associated to restricted diet. Successful therapy was defined as percent loss of total weight (%LTW) > or = 5 % at six months after balloon placement and 6 and 12 months after their withdrawal. All analyses followed intention-to treat principles considering significant p-values < 0.05. we placed 73 fluid-filled balloons (80.2 %) and 18 air-filled ones (19.8 %). Compared to baseline values, at 6-month 73.7 % subjects succeeded, showing significant reductions in weight (13.3 +/- 8.8 kg), BMI (5 +/- 3.4 kg/m2) (p < 0.0001), with % LTW 11 +/- 7 %. Six and twelve months after retrieval 45.1 % and 28.6 % patients reached % LTW > or = 5 %. Short-term and medium-term effectiveness was negatively associated to obesity in first-grade relatives (p = 0.003 and p = 0.04). Higher weight loss 6 months after balloon placement independently predicted medium-term effectiveness (p = 0.0001). Mortality was absent but there were two spontaneous deflations of air-filled balloons and severe withdrawal difficulties in 8 patients, leading to surgery in one case. Retrieval complications associated to air-filled balloons (p = 0.0005). in obesity, effectiveness of gastric balloons associated to hypocaloric diet decreases over time.Complications occurred mainly in the retrieval endoscopic procedure and related to air-filled balloons.

  6. Impact of 6 months of treatment with intragastric balloon on body fat and quality of life in obese individuals with metabolic syndrome.

    PubMed

    Guedes, Erika Paniago; Madeira, Eduardo; Mafort, Thiago Thomaz; Madeira, Miguel; Moreira, Rodrigo Oliveira; de Mendonça, Laura Maria Carvalho; de Godoy-Matos, Amélio Fernando; Lopes, Agnaldo José; Farias, Maria Lucia Fleiuss

    2017-10-24

    Obesity is a worldwide public health issue with a negative impact on quality of life. Different weight loss interventions have demonstrated improvements in quality of life. The aim of this study was to investigate the effect of 6 months of treatment with an intragastric balloon (IGB) on health-related quality of life (HRQOL) and its relation to changes in body fat in obese individuals with metabolic syndrome (MS). Fifty obese patients with MS aged 18-50 were selected for treatment with IGB for 6 months. Body fat was assessed with anthropometric measures and dual-energy X-ray absorptiometry (DXA) at baseline and after removal of the IGB. HRQOL was evaluated with the short form of the World Health Organization Quality of Life (WHOQOL-BREF) at baseline and soon after removal of the IGB. Thirty-nine patients completed the study. After 6 months, there was a significant improvement in quality of life (p = 0.0009) and health (p < 0.0001) perceptions, and in the Physical (p = 0.001), Psychological (p = 0.031), and Environmental domains (p = 0.0071). Anthropometric measures and total fat determined by DXA were directly and significantly related to an improvement in general aspects of quality of life. The decrease in the percentage of total fat was the parameter that better correlated with improvements in quality of life perception after regression (p = 0.032). In obese individuals with MS, weight loss parameters were associated with short-term improvements in HRQOL after 6 months of treatment with IGB. However, only total fat was independently related to HRQOL perception. ClinicalTrials.gov NCT01598233 .

  7. Intragastric nitrites, nitrosamines, and bacterial overgrowth during cimetidine treatment.

    PubMed Central

    Stockbrugger, R W; Cotton, P B; Eugenides, N; Bartholomew, B A; Hill, M J; Walters, C L

    1982-01-01

    A six week course of cimetidine (1 g/day) healed peptic ulcers in 20 of 23 patients (14 with duodenal ulcer, nine with gastric ulcer). Reduction of basal acid output by 73% and peak acid output by 36% led to a rise in concentrations of intragastric aerobic bacteria and nitrate-reducing bacteria. While the mean intragastric concentration of nitrate was unchanged by treatment, there were statistically significant rises in nitrite and N-nitrosamine concentrations. The conversion from nitrates to nitrites was closely related to the occurrence of nitrate-reducing bacteria. In three patients the intragastric milieu had returned to normal two months after cimetidine treatment had been discontinued. Mean nitrite and N-nitrosamine concentrations did not return to pre-treatment levels in the group of eight patients who remained on maintenance cimetidine (0.4 g at night-time) for three months after the full dose treatment. This study shows that cimetidine treatment can create an intragastric milieu resembling that of atrophic gastritis. Large scale and long-term studies are necessary to establish whether these findings have any clinical significance. PMID:7173716

  8. Estimation of intragastric solubility of drugs: in what medium?

    PubMed

    Vertzoni, Maria; Pastelli, Eleni; Psachoulias, Dimitris; Kalantzi, Lida; Reppas, Christos

    2007-05-01

    To measure the solubility of four drugs in human gastric aspirates, canine gastric aspirates (CGF) and simulated gastric fluids in order to propose a medium for estimating intragastric drug solubility relevant to a bioavailability study in the fasted state. Intragastric environment after administration of water to healthy fasted adults and to healthy fasted dogs (this study) was initially characterized. Solubilities were then measured with the shake-flask method in gastric fluid aspirated after the administration of water to healthy fasted adults and to healthy fasted dogs, in various simulated gastric fluids, i.e. SGF(SLS), SGF(Triton), FaSSGF, FaSSGF(NaCl), and in various HCl solutions with pH values ranging from 1.2 to 2.9. In all cases, FaSSGF performed better than canine aspirates, SGF(SLS), SGF(Triton), or FaSSGF(NaCl) in predicting solubility in HGF. However, its superiority over HCl pH 1.6 was not clear. For ketoconazole, dipyridamole, miconazole, and felodipine deviations of solubility data in FaSSGF from solubility data in HGF were non-significant, 34, -39 and 252%, respectively, whereas the corresponding deviations of data in HCl pH 1.6 from data in HGF were non-significant, 24, 70, and 130%, respectively. Combining data in FaSSGF and HCl pH 1.6 is comparatively the most efficient way to get an estimate of drug solubility in the fasting gastric contents during a bioavailability study. However, accurate estimation of intragastric solubility is limited by the changing environment during intragastric residence of solid particles and the degree of simulation of intragastric composition.

  9. [Efficiency of endoscopic treatment with intra gastric balloon in severe to morbid obesity].

    PubMed

    Houissa, Fatma; Trabelsi, Senda; Hadj Brahim, Kamel; Mouelhi, Leila; Bouzaidi, Slim; Salem, Mohamed; Mekki, Haiffa; El Jery, Kaouther; Said, Yosra; Kheder, Sana; Debbech, Radhouane; Najjar, Taoufik

    2014-12-01

    Obesity raises such a healthcare matter throughout the world. Its management is not only complex but also most often multidisciplinary. The medico-dietary treatment is of inconstant efficiency and the surgical treatment, though more efficient, presents a considerable morbidity-death rate. The endoscopic treatment through intra-gastric balloon avails a seducing alternative namely accounting for surgery preparation. To assess the efficiency of the endoscopic treatment through gastric balloon, both in the short and long term, and this is accounting for weight loss as well as tolerance. We have carried out a retrospective study including the patients suffering from severe to morbid obesity and who had a gastric balloon implemented in our Endoscopy Unit between November 2005 and December 2007. Twenty one patients were included. The average age was 32,19 ± 12,65 years with extremes of 16 and 52 years. Fifteen patients suffered from morbid obesity. The patients' average weight was 134, 52 ± 26,46 kg (extremes 88 and 194 kg). Some co-morbidity was found out with 15 patients. Te balloon implementation (Héliosphère®) was carried out with no incidents in all patients. Six months after the balloon implementation, the average weight loss was 17,5% and the average loss of over weigh was 37%. In biological level, we noted a normalisation of fasting glycaemia in 28,6 % of cases, of the cholesterolemia in 100 %, of the triglyceridemia in 33,33%, of the uraemia in 42,8% and hepatic tests in 50 % of the cases. The metabolic syndrome disappeared in 28,57 % of cases. The assessment after a 5-year-period was marked by the need to surgical treatment in 4 patients and this is due to the loss of efficiency of endoscopic treatment. A bad tolerance of gastric balloon was observed in 34 % of the cases, dominated by sicknesses. Only one patient presented incoercible sicknesses with ionic troubles as well as deshydrating requiring the precocious extraction of the balloon after 48 hours of

  10. Equivalence of litmus paper and intragastric pH probes for intragastric pH monitoring in the intensive care unit.

    PubMed

    Levine, R L; Fromm, R E; Mojtahedzadeh, M; Baghaie, A A; Opekun, A R

    1994-06-01

    To compare the accuracy of litmus paper-determined gastric pH to a nasogastric graphite antimony pH probe. A prospective clinical trial of gastric pH determination in patients enrolled in a study of histamine-2-receptor (H2) antagonists. The medical intensive care unit (ICU) of a 450-bed county hospital. Critically ill ICU patients requiring stress ulcer prophylaxis. Using a crossover design, the patients were randomized to initially receive an H2 antagonist by continuous infusion or intravenous bolus, and subsequently were crossed over to the other limb of the study. Gastric pH was determined using pH-sensitive litmus paper at the initiation of each limb of the study and at 1, 2, 4, and 8 hrs after the initiation of H2 receptor antagonist therapy. In addition, gastric pH was continuously determined over the same time period utilizing a graphite antimony pH probe. Gastric pH measurements determined with litmus paper and intragastric pH probes demonstrated an excellent correlation (r2 = .93, p < .001). McNemar's test of correlated proportions could not demonstrate a significant difference between the two monitoring methods (chi-square = 0.5, p > .47), and the kappa statistic (0.95, p < .001) demonstrated excellent concordance. Bias measurement was 0.01 (95% confidence interval = -0.155 to 0.176). Measurement of intragastric pH, using pH-sensitive litmus paper, is both sensitive and specific when utilizing a graphite antimony nasogastric pH probe as a reference standard. Litmus paper-determined gastric pH testing is both easy to perform and inexpensive. Therefore, based on the current data, we believe this technique (i.e., litmus paper determined gastric pH testing) to be the method of choice for determination of intragastric pH in patients at risk for stress gastric ulcers in the medical ICU.

  11. Repeated Famotidine Administration Results in a Diminished Effect on Intragastric pH in Dogs.

    PubMed

    Tolbert, M K; Graham, A; Odunayo, A; Price, J; Steiner, J M; Newkirk, K; Hecht, S

    2017-01-01

    Famotidine is an acid suppressant commonly administered to dogs. Prolonged famotidine use in people results in decreased efficacy, but the effect in dogs is unknown. To compare the effect of repeated oral administration of famotidine or placebo on intragastric pH and serum gastrin in dogs. We hypothesized that famotidine would have a diminished effect on intragastric pH on day 13 compared to day 1. Six healthy adult colony Beagles. Randomized, 2-factor repeated-measures crossover design. All dogs received oral placebo or 1.0 mg/kg famotidine q12h for 14 consecutive days. Intragastric pH monitoring was used to continuously record intragastric pH on treatment days 1-2 and 12-13. Mean pH as well as mean percentage time (MPT) that intragastric pH was ≥3 or ≥4 were compared between and within groups by analysis of variance. Serum gastrin was measured on days 0, 3, and 12 for each treatment. Continued administration of famotidine resulted in a significant decrease in mean pH, MPT ≥3, and MPT ≥4 (P < .0001) on day 12 and 13. This resulted in a mean decrease in pH by 1.63 on days 12 and 13 compared to days 1 and 2. Furthermore, a mean decrease of MPT ≥3 and MPT ≥4 by 33 and 45% was observed for the same time period, respectively. Continued administration of famotidine results in a diminished effect on intragastric pH in dogs. Caution is advised when recommending long-term, daily oral administration of famotidine to dogs. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  12. Ballooning Then...and Ballooning Now.

    ERIC Educational Resources Information Center

    Journal of Aerospace Education, 1978

    1978-01-01

    Describes the history of hot-air balloon travel, starting with its French origins and continuing through to the 1978 national championship. An address for Balloon Federation of America membership is included. (MA)

  13. Use of a modified N-nitrosoproline test to show intragastric nitrosation in patients at risk of gastric cancer.

    PubMed Central

    Houghton, P. W.; Leach, S.; Owen, R. W.; McC Mortensen, N. J.; Hill, M. J.; Williamson, R. C.

    1989-01-01

    Intragastric nitrosation has been implicated in the pathogenesis of gastric cancer and in precancerous conditions such as pernicious anaemia and the post-gastrectomy state. Intragastric nitrosation was assessed in at-risk patients by N-nitrosoproline (NPRO) excretion using both a conventional and a modified test. Twenty-four hour urinary excretion of NPRO was measured after oral administration of sodium nitrate (300 mg) and L-proline (500 mg) as an indirect indicator of intragastric nitrosation. In the conventional test no differences in intragastric nitrosation were found between at-risk patients and controls. In the modified test the loading dose of sodium nitrate was omitted and urinary NPRO levels were found to be significantly increased in Polya partial gastrectomy patients (P = 0.003) and post-vagotomy patients (P = 0.03) compared to controls. In pernicious anaemia patients NPRO levels were also higher than in controls but just failed to reach statistical significance. This study has confirmed that hypochlorhydria results in increased intragastric nitrosation, thus facilitating the formation of potentially carcinogenic N-nitroso compounds. PMID:2765371

  14. Serum metabolic changes in rats after intragastric administration of dextromethorphan.

    PubMed

    Bao, Shihui; Zhang, Jing; Lin, Zixia; Su, Ke; Mo, Jingjing; Hong, Lin; Qian, Shuyi; Chen, Lianguo; Sun, Fa; Wen, Congcong; Wu, Qing; Hu, Lufeng; Lin, Guanyang; Wang, Xianqin

    2017-03-01

    Dextromethorphan is recognized as a substance of abuse around the world. An estimated 3.1 million people between the ages of 12 and 25 years (5.3%) misused over-the-counter cough and cold medications in 2006. In this study, we developed a serum metabolomic method by gas chromatography-mass spectrometry (GC-MS) to evaluate the effect of abuse of dextromethorphan on rats. The dextromethorphan-treated rats were given 12, 24 and 48 mg/kg (low, medium, high) of dextromethorphan by intragastric administration each day for 3 days. Partial least squares-discriminate analysis revealed that intragastric administration of dextromethorphan induced metabolic perturbations. Compared with the control (healthy) group, the levels of propanoic acid, urea, heptafluorobutanoic acid, 2-hexyldecanoic acid and butanedioic acid of the low group decreased; levels of propanoic acid and heptafluorobutanoic acid of the medium group decreased, while that of benzoic acid increased; and levels of 2-hexyldecanoic acid, glycerol and butanedioic acid of the high group increased. These biomarkers are involved in the citric acid cycle, urea cycle, glycerolipid metabolism and tricarboxylic acid cycle. The results indicate that the metabolomic method by GC-MS may be useful to elucidate abuse of dextromethorphan. According to the pathological changes in the liver at different dosages, dextromethorphan is not hepatotoxic after intragastric administration of 12, 24 and 48 mg/kg for 3 days. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Intragastric infusion of denatonium benzoate attenuates interdigestive gastric motility and hunger scores in healthy female volunteers.

    PubMed

    Deloose, Eveline; Janssen, Pieter; Corsetti, Maura; Biesiekierski, Jessica; Masuy, Imke; Rotondo, Alessandra; Van Oudenhove, Lukas; Depoortere, Inge; Tack, Jan

    2017-03-01

    Background: Denatonium benzoate (DB) has been shown to influence ongoing ingestive behavior and gut peptide secretion. Objective: We studied how the intragastric administration of DB affects interdigestive motility, motilin and ghrelin plasma concentrations, hunger and satiety ratings, and food intake in healthy volunteers. Design: Lingual bitter taste sensitivity was tested with the use of 6 concentrations of DB in 65 subjects. A placebo or 1 μmol DB/kg was given intragastrically to assess its effect on fasting gastrointestinal motility and hunger ratings, motilin and ghrelin plasma concentrations, satiety, and caloric intake. Results: Women ( n = 39) were more sensitive toward a lingual bitter stimulus ( P = 0.005) than men ( n = 26). In women ( n = 10), intragastric DB switched the origin of phase III contractions from the stomach to the duodenum ( P = 0.001) and decreased hunger ratings ( P = 0.04). These effects were not observed in men ( n = 10). In women ( n = 12), motilin ( P = 0.04) plasma concentrations decreased after intragastric DB administration, whereas total and octanoylated ghrelin were not affected. The intragastric administration of DB decreased hunger ( P = 0.008) and increased satiety ratings ( P = 0.01) after a meal (500 kcal) in 13 women without affecting gastric emptying in 6 women. Caloric intake tended to decrease after DB administration compared with the placebo (mean ± SEM: 720 ± 58 compared with 796 ± 45 kcal; P = 0.08) in 20 women. Conclusions: Intragastric DB administration decreases both antral motility and hunger ratings during the fasting state, possibly because of a decrease in motilin release. Moreover, DB decreases hunger and increases satiety ratings after a meal and shows potential for decreasing caloric intake. This trial was registered at clinicaltrials.gov as NCT02759926. © 2017 American Society for Nutrition.

  16. Telomere length elongation after weight loss intervention in obese adults.

    PubMed

    Carulli, L; Anzivino, C; Baldelli, E; Zenobii, M F; Rocchi, M B L; Bertolotti, M

    2016-06-01

    Telomeres may be considered markers of biological aging, shorter telomere length is associated with some age-related diseases; in several studies short telomere length has also been associated to obesity in adults and adolescents. However the relationship between telomere complex functions and obesity is still not clear. Aim of the study was to assess telomere length (TL) in adults' obese subjects before and after weight loss obtained by placement of bioenteric intragastric balloon (BIB) for 6months. We enrolled 42 obese subjects before and after BIB placement as weight loss intervention. Blood samples were collected in order to obtain DNA from leukocyte to measure TL by quantitative PCR. Data were analyzed only in 37 subjects with complete data; all presented important body weight loss (124.06±26.7 vs 105.40±23.14, p<0.001) and more interesting they presented a significant increase in TL (3.58±0.83 vs 5.61±3.29, p<0.001). Moreover we observed a significant positive correlation between TL elongation and weight loss (r=0.44, p=0.007) as well as an inverse correlation between TL at baseline and TL elongation (r=-0.35, p=0.03).The predictors of TL elongation were once again weight loss and short TL at baseline (respectively p=0.007 and p=0.003). Our study shows that weight loss is associated to telomere lengthening in a positive correlation: the greater weight loss the greater telomere lengthening; moreover telomere lengthening is more significant in those subjects with shortest telomeres at baseline. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Effect of esomeprazole and rabeprazole on intragastric pH in healthy Chinese: an open, randomized crossover trial.

    PubMed

    Li, Zhao-Shen; Zhan, Xian-Bao; Xu, Guo-Ming; Cheng, Neng-Neng; Liao, Zhuan

    2007-06-01

    Esomeprazole is the S-isomer of omeprazole, with a stronger acid suppressive effect than omeprazole. This open, randomized crossover study was designed to evaluate the effect of esomeprazole and another proton-pump inhibitor, rabeprazole, on intragastric pH in healthy Chinese. Thirty-six healthy volunteers (26 men and 10 women, aged between 20 and 31 years) were enrolled. Subjects were given either esomeprazole 40 mg (n = 18) or rabeprazole 10 mg (n = 18) orally once daily for 5 days during the first dosing period, then the other medicine at the set dosage for the second dosing period. The two periods were separated by a 14-day washout phase. The doses were chosen according to the State Food and Drug Administration of China for the treatment of acid-related diseases. Intragastric pH was continuously monitored for 24 h on days 1 and 5 of each dosing period. CYP2C19 genotypes were analyzed to identify the extensive metabolizers (EM) and poor metabolizers (PM). The percentage of time with intragastric pH >4 was significantly higher (P < 0.001) in subjects receiving esomeprazole than in those receiving rabeprazole in the first 4 h after administration of the first dose (70.65% vs 44.87%), at 24 h on day 1 (73.7% vs 54.8%) and at 24 h on day 5 (84.2% vs 76.2%). The median intragastric pH was also higher in subjects receiving esomeprazole than in those receiving rabeprazole in the first 6 h, day 1 and day 5 (P intragastric pH >4 for at least 16 h on day 1 (63.9% vs 33.3%) and on day 5 (88.9% vs 61.1%) was higher after administration of esomeprazole than after rabeprazole (both P < 0.05). On genotype analysis, 28 of the subjects were EM and eight were PM. Those who were PM tended to have a higher, albeit not statistically significant, percentage of time with intragastric pH >4 and the median 24-h intragastric pH than those who were EM. Both drugs were well tolerated. Esomeprazole 40 mg orally once daily is more effective and

  18. Japanese Balloon Program

    NASA Astrophysics Data System (ADS)

    Yoshida, Tetsuya; Fuke, Hideyuki; Shoji, Yasuhiro; Iijima, Issei; Izutsu, Naoki; Kato, Yoichi; Matsuzaka, Yukihiko; Mizuta, Eiichi; Sato, Takatoshi; Tamura, Keisuke; Saito, Yoshitaka; Kakehashi, Yuya

    2012-07-01

    Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency conducts domestic balloon campaigns at Taiki Aerospace Research Field (TARF) in Hokkaido since 2008. The ballooning at TARF becomes stable after four year operation. Because the field faces to the Pacific Ocean, heavy balloons and payloads can be launched safely using a very unique sliding launcher. Recoveries at the inshore along the Tokachi coast can be done very quickly and smoothly. Unfortunately, flight opportunities are recently limited due to unfriendly weather condition. Unstable Jet stream also prevents us to have so-called `boomerang flight' to achieve long flight duration more than several hours. Six balloon-borne experiments were carried out in 2010 and 2011. Three of them were demonstrations of challenges of space engineering, two were in-situ atmospheric observation, and one was the technical flight of new high-resolution γ-ray telescope. In addition to these flights, we carried out two launches for next generation balloons: one for Tawara-shaped superpressure balloon and the other for ultra-thin high-altitude balloon. In this paper, recent activities of the Japanese scientific balloon program will be introduced. On-going development of the balloon system will also be presented.

  19. Balloons and Science Kit.

    ERIC Educational Resources Information Center

    Balloon Council, Washington, DC.

    This document provides background information on balloons including: (1) the history of balloons; (2) balloon manufacturing; (3) biodegradability; (4) the fate of latex balloons; and (5) the effect of balloons on the rainforest and sea mammals. Also included as part of this instructional kit are four fun experiments that allow students to…

  20. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    NASA Astrophysics Data System (ADS)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  1. GHOST balloons around Antarctica

    NASA Technical Reports Server (NTRS)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  2. Technical innovation: Intragastric Single Port Sleeve Gastrectomy (IGSG). A feasibility survival study on porcine model.

    PubMed

    Estupinam, Oscar; Oliveira, André Lacerda de Abreu; Antunes, Fernanda; Galvão, Manoel; Phillips, Henrique; Scheffer, Jussara Peters; Rios, Marcelo; Zorron, Ricardo

    2018-01-01

    To perform technically the laparoscopic sleeve gastrectomy (LSG) using a unique Intragastric Single Port (IGSG) in animal swine model, evidencing an effective and safe procedure, optimizing the conventional technique. IGSG was performed in 4 minipigs, using a percutaneous intragastric single port located in the pre-pyloric region. The gastric stapling of the greater curvature started from the pre-pyloric region towards the angle of His by Endo GIA™ system and the specimen was removed through the single port. In the postoperative day 30, the animals were sacrificed and submitted to autopsy. All procedures were performed without conversion, and all survived 30 days. The mean operative time was 42 min. During the perioperative period no complications were observed during invagination and stapling. No postoperative complications occurred. Post-mortem examination showed no leaks or infectious complications. Intragastric Single Port is a feasible procedure that may be a suitable alternative technique of sleeve gastrectomy for the treatment of morbid obesity.

  3. Comparison of p.o. or i.v. proton pump inhibitors on 72-h intragastric pH in bleeding peptic ulcer.

    PubMed

    Javid, Gul; Zargar, Showkat Ali; U-Saif, Riyaz-; Khan, Bashir Ahmad; Yatoo, Ghulam Nabi; Shah, Altaf Hussain; Gulzar, Ghulam Mohammad; Sodhi, Jaswinder Singh; Khan, Mushtaq Ahmad

    2009-07-01

    After successful endoscopic hemostasis in bleeding peptic ulcer, addition of proton pump inhibitors reduce the rate of recurrent bleeding by maintaining intragastric pH at neutral level. The aim of the present study was to evaluate the effect of various proton pump inhibitors given through different routes on intragastric pH over 72 h after endoscopic hemostasis in bleeding peptic ulcer. Ninety consecutive patients who had successful endoscopic therapy of bleeding peptic ulcer underwent 72-h continuous ambulatory intragastric pH study, were randomly assigned to receive p.o. omeprazole 80 mg bolus followed by 40 mg every 12 h for 72 h or i.v. 80 mg omeprazole followed by infusion 8 mg/h for 72 h. Oral pantoprazole 80 mg bolus followed by 80 mg every 12 h for 72 h or i.v. 80 mg pantoprazole followed by infusion of 8 mg/h for 72 h. Oral rabeprazole 80 mg bolus followed by 40 mg every 12 h for 72 h or i.v. 80 mg rabeprazole followed by infusion 8 mg/h for 72 h. Five patients received no treatment after successful endoscopic therapy and underwent 72-h pH study. Mean 72-h intragastric pH for p.o. omeprazole was 6.56 versus 6.93 for omeprazole infusion (P = 0.48). Mean 72-h intragastric pH for p.o. pantoprazole was 6.34 versus 6.32 for pantoprazole infusion (P = 0.62). Mean 72-h intragastric pH for rabeprazole p.o. was 6.11 versus 6.18 rabeprazole i.v. (P = 0.55). Mean 72-h pH for the no proton pump inhibitor group was 2.04. There was no significant difference among various proton pump inhibitors given through different routes on raising intragastric pH above 6 for 72 h after successful endoscopic hemostasis in bleeding peptic ulcer.

  4. Ballooning Comes of Age: Make Your Own Balloon.

    ERIC Educational Resources Information Center

    Eckford, Jim

    1983-01-01

    Provides instructions for building a working model of a hot-air balloon, offering suggestions for a successful flight. Indicates that children can be involved in the projects, for example, by filling in colors in the panels of a balloon drawing. (JN)

  5. Energy from solar balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grena, Roberto

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  6. Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis.

    PubMed

    Jing, Zehao; Dong, Jianli; Li, Zhengwei; Nan, Feng

    2018-06-19

    Kyphoplasty has been widely used to treat vertebral compression fractures (VCFs). In standard procedure of kyphoplasty, two balloons were inserted into the vertebral body through bipedicular and inflated simultaneously, while using a single balloon two times is also a common method in clinic to lessen the financial burden of patients. However, the effect and safety of single balloon versus double balloon bipedicular kyphoplasty are still controversy. In this systematic review and meta-analysis, eligible studies were identified through a comprehensive literature search of PubMed, Cochrane library EMBASE, Web of Science, Wanfang, CNKI, VIP and CBM until January 1, 2018. Results from individual studies were pooled using a random or fixed effects model. Seven articles were included in the systematic review and five studies were consisted in meta-analysis. We observed no significant difference between single balloon and double balloon bipedicular kyphoplasty in visual analog scale (VAS), angle (kyphotic angle and Cobb angle), consumption (operation time, cement volume and volume of bleeding), vertebral height (anterior height, medium height and posterior height) and complications (cement leakage and new VCFs), while the cost of single balloon bipedicular kyphoplasty is lower than that of double balloon bipedicular kyphoplasty. The results of our meta-analysis also demonstrated that single balloon can significantly improve the VAS, angle and vertebral height of patients suffering from VCFs. This systematic review and meta-analysis collectively concludes that single balloon bipedicular kyphoplasty is as effective as double balloon bipedicular kyphoplasty in improving clinical symptoms, deformity and complications of VCFs but not so expensive. These slides can be retrieved under Electronic Supplementary Material.

  7. Bioavailability and pharmacokinetics of oral and injectable formulations of methadone after intravenous, oral, and intragastric administration in horses.

    PubMed

    Linardi, Renata L; Stokes, Ashley M; Keowen, Michael L; Barker, Steven A; Hosgood, Giselle L; Short, Charles R

    2012-02-01

    To characterize the bioavailability and pharmacokinetics of oral and injectable formulations of methadone after IV, oral, and intragastric administration in horses. 6 healthy adult horses. Horses received single doses (each 0.15 mg/kg) of an oral formulation of methadone hydrochloride orally or intragastrically or an injectable formulation of the drug orally, intragastrically, or IV (5 experimental treatments/horse; 2-week washout period between each experimental treatment). A blood sample was collected from each horse before and at predetermined time points over a 360-minute period after each administration of the drug to determine serum drug concentration by use of gas chromatography-mass spectrometry analysis and to estimate pharmacokinetic parameters by use of a noncompartmental model. Horses were monitored for adverse effects. In treated horses, serum methadone concentrations were equivalent to or higher than the effective concentration range reported for humans, without induction of adverse effects. Oral pharmacokinetics in horses included a short half-life (approx 1 hour), high total body clearance corrected for bioavailability (5 to 8 mL/min/kg), and small apparent volume of distribution corrected for bioavailability (0.6 to 0.9 L/kg). The bioavailability of methadone administered orally was approximately 3 times that associated with intragastric administration. Absorption of methadone in the small intestine in horses appeared to be limited owing to the low bioavailability after intragastric administration. Better understanding of drug disposition, including absorption, could lead to a more appropriate choice of administration route that would enhance analgesia and minimize adverse effects in horses.

  8. Initial Weight Loss after Restrictive Bariatric Procedures May Predict Mid-Term Weight Maintenance: Results From a 12-Month Pilot Trial.

    PubMed

    Nikolić, Marko; Kruljac, Ivan; Kirigin, Lora; Mirošević, Gorana; Ljubičić, Neven; Nikolić, Borka Pezo; Bekavac-Bešlin, Miroslav; Budimir, Ivan; Vrkljan, Milan

    2015-06-01

    Background: Bariatric procedures are effective options for weight loss (WL) in the morbidly obese. However, some patients fail to lose any weight after bariatric surgery, and mid-term weight maintenance is variable. The aim of this study was to investigate whether initial WL could predict mid-term weight maintenance. Methods: Eighty patients were enrolled, of whom 44 were treated with the BioEnterics Intragastric Balloon (BIB), 21 with laparoscopic adjustable gastric lap-banding (LAGB), and 15 with laparoscopic sleeve gastrectomy (LSG). Percentage of body WL and percentage of excess weight loss (EWL) were calculated at baseline and after 1, 3, 6, and 12 months. Successful WL was defined as EWL >20% for patients treated with BIB and >50% for patients treated with LAGB and SG. Results: Success in the 6th and 12th month was achieved in 80% and 58% of patients in the BIB group, 33% and 40% in the LAGB group, and 60% and 73% in the LSG group. In the BIB group, WL in the 1st month correlated positively with WL at the 6th and 12th month, and an initial WL >6.5% best predicted success (sensitivity 50%, specificity 80%). A similar association was observed in the LAGB group at the 6th and 12th month and an initial WL >9.4% best predicted success (sensitivity 90.0%, specificity 81.2%). In patients treated with LSG, WL in the 3rd month correlated positively with EWL at the 6th and 12th month, with a cutoff value of 17% (sensitivity 66.7%, specificity 100%). Conclusions: WL in the 1st month in patients treated with BIB and LAGB and WL in the 3rd month in patients treated with LSG could be used as a prognostic factor to predict mid-term weight maintenance.

  9. Balloon Design Software

    NASA Technical Reports Server (NTRS)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  10. Continuous versus bolus intragastric tube feeding for preterm and low birth weight infants with gastro-oesophageal reflux disease.

    PubMed

    Richards, Robyn; Foster, Jann P; Psaila, Kim

    2014-07-17

    Gastro-oesophageal reflux disease is a particularly common condition in preterm and low birth weight infants. These infants are also more likely to have excessive regurgitation, as they do not have a fully developed antireflux mechanism. Preterm and low birth weight infants who are unable to suck oral feeds are required to be fed via an intragastric tube for varying lengths of time. Intragastric tube feeding can be delivered by the intermittent bolus or continuous feeding method. Use of continuous or intermittent bolus intragastric feeding may have a positive or negative effect on the incidence or severity of gastro-oesophageal reflux disease. To determine whether continuous or intermittent bolus intragastric tube feeding reduces the number of episodes and the duration of gastro-oesophageal reflux disease (GORD) in preterm and low birth weight infants.We intended to perform subgroup analyses for gestational age; birth weight; age in days from birth at full enteral feeding via intragastric tube (breast vs bottle); frequency of intermittent bolus feed; and type of medication for treatment of GORD (only if medication prescribed and given similarly to both intervention groups). We used the standard search strategy of the Cochrane Neonatal Group as described in The Cochrane Library (www.thecochranelibrary.com) to search for randomised controlled trials (RCTs) in the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 9), MEDLINE (1966 to September 2013), EMBASE (1980 to September 2013) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to September 2013). We also searched previous reviews, including cross-references, abstracts and conference and symposia proceedings of the Perinatal Society of Australia and New Zealand and the Pediatric Academic Societies (American Pediatric Society/Society for Pediatric Research and European Society for Paediatric Research) from 1990 to 2012. Published and unpublished RCTs and quasi

  11. Balloon dilatation of benign and malignant esophageal strictures. Blind retrograde balloon dilatation.

    PubMed

    Graham, D Y; Smith, J L

    1985-06-01

    Balloon esophageal dilatation offers many theoretical advantages (safety, speed, and patient comfort) over dilatation with mercury-filled bougies or with the Eder-Puestow system. The authors used balloon dilators in 22 patients with dysphagia secondary to benign or malignant strictures. Dilatation was performed with fluoroscopic guidance, blindly, or by a combination of these techniques. For "blind" stricture dilatation, an Eder-Puestow spring-tipped guide wire is placed into the stomach using a fiberoptic endoscope. The distance from the incisor teeth to the stricture is measured, and the balloon shaft is marked to indicate when the middle of the balloon is within the stricture. Dilatation is then performed using the antegrade or, the preferred, retrograde technique. Finally, the dilated stricture is calibrated by pulling an inflated balloon through the previously strictured area without difficulty. An attempt was made to achieve an esophageal diameter of 15 mm at the initial dilatation episode, and patient discomfort was used as a guide as to the final diameter. The balloon dilatation technique was highly successful, and a stricture diameter of 15 mm (45-47 French) was achieved at the initial dilatation in most instances. Malignant strictures were easily dilated. Balloon dilatation is convenient, effective, quick, and potentially safer than the previous Eder-Puestow or mercury-filled bougie techniques.

  12. Scientific Balloons for Venus Exploration

    NASA Astrophysics Data System (ADS)

    Cutts, James; Yavrouian, Andre; Nott, Julian; Baines, Kevin; Limaye, Sanjay; Wilson, Colin; Kerzhanovich, Viktor; Voss, Paul; Hall, Jeffery

    Almost 30 years ago, two balloons were successfully deployed into the atmosphere of Venus as an element of the VeGa - Venus Halley mission conducted by the Soviet Union. As interest in further Venus exploration grows among the established planetary exploration agencies - in Europe, Japan, Russia and the United States, use of balloons is emerging as an essential part of that investigative program. Venus balloons have been proposed in NASA’s Discovery program and ESA’s cosmic vision program and are a key element in NASA’s strategic plan for Venus exploration. At JPL, the focus for the last decade has been on the development of a 7m diameter superpressure pressure(twice that of VeGa) capable of carrying a 100 kg payload (14 times that of VeGA balloons), operating for more than 30 days (15 times the 2 day flight duration of the VeGa balloons) and transmitting up to 20 Mbit of data (300 times that of VeGa balloons). This new generation of balloons must tolerate day night transitions on Venus as well as extended exposure to the sulfuric acid environment. These constant altitude balloons operating at an altitude of about 55 km on Venus where temperatures are benign can also deploy sondes to sound the atmosphere beneath the probe and deliver deep sondes equipped to survive and operate down to the surface. The technology for these balloons is now maturing rapidly and we are now looking forward to the prospects for altitude control balloons that can cycle repeatedly through the Venus cloud region. One concept, which has been used for tropospheric profiling in Antarctica, is the pumped-helium balloon, with heritage to the anchor balloon, and would be best adapted for flight above the 55 km level. Phase change balloons, which use the atmosphere as a heat engine, can be used to investigate the lower cloud region down to 30 km. Progress in components for high temperature operation may also enable investigation of the deep atmosphere of Venus with metal-based balloons.

  13. Scientific Ballooning Activities and Recent Developments in Technology and Instrumentation of the TIFR Balloon Facility, Hyderabad

    NASA Astrophysics Data System (ADS)

    Buduru, Suneel Kumar

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.

  14. Telescope Systems for Balloon-Borne Research

    NASA Technical Reports Server (NTRS)

    Swift, C. (Editor); Witteborn, F. C. (Editor); Shipley, A. (Editor)

    1974-01-01

    The proceedings of a conference on the use of balloons for scientific research are presented. The subjects discussed include the following: (1) astronomical observations with balloon-borne telescopes, (2) orientable, stabilized balloon-borne gondola for around-the-world flights, (3) ultraviolet stellar spectrophotometry from a balloon platform, (4) infrared telescope for balloon-borne infrared astronomy, and (5) stabilization, pointing, and command control of balloon-borne telescopes.

  15. Status of the NASA Balloon Program

    NASA Astrophysics Data System (ADS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  16. The National Scientific Balloon Facility. [balloon launching capabilities of ground facility

    NASA Technical Reports Server (NTRS)

    Kubara, R. S.

    1974-01-01

    The establishment and operation of the National Scientific Balloon Facility are discussed. The balloon launching capabilities are described. The ground support systems, communication facilities, and meteorological services are analyzed.

  17. Investigation of hot air balloon fatalities.

    PubMed

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  18. A comparative study of internally and externally capped balloons using small scale test balloons

    NASA Technical Reports Server (NTRS)

    Bell, Douglas P.

    1994-01-01

    Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.

  19. Balloons Revisited

    ERIC Educational Resources Information Center

    Jeskova, Z.; Featonby, D.; Fekova, V.

    2012-01-01

    Whilst everyone is familiar with the process of blowing up a balloon, few of us have gone further to quantify the actual pressures involved at different stages in the inflation process. This paper seeks to describe experiments to fill some of those gaps and examine some of the apparently anomalous behaviour of connected balloons. (Contains 12…

  20. Unmanned powered balloons

    NASA Technical Reports Server (NTRS)

    Korn, A. O.

    1975-01-01

    In the late 1960's several governmental agencies sponsored efforts to develop unmanned, powered balloon systems for scientific experimentation and military operations. Some of the programs resulted in hardware and limited flight tests; others, to date, have not progressed beyond the paper study stage. Balloon system designs, materials, propulsion units and capabilities are briefly described, and critical problem areas are pointed out which require further study in order to achieve operational powered balloon systems capable of long duration flight at high altitudes.

  1. Scientific Ballooning in India - Recent Developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  2. Percutaneous balloon pulmonary valvuloplasty (PBPV) of extreme pulmonary valve stenosis by the use of Accura balloon.

    PubMed

    Sinha, Santosh Kumar; Mishra, Vikas; Razi, Mahmadula; Jha, Mukesh Jitendra

    2017-10-04

    Transcatheter therapy of valvular pulmonary stenosis is one of first catheter interventions facilitating its application in field of structural heart disease and now treatment of choice for significant pulmonary stenosis. Myriads of balloon catheter have been used for this purpose starting from Diamond (Boston Scientific,Natick, MA USA), Marshal (Medi-Tech,Watertown MAUSA), Innoue balloon, Tyshak I and currently Tyshak II. Diameter and length of balloon depend on size of annulus and age group, respectively. Problem with shorter balloon is difficulty in keeping it across the annulus while inflation as it tends to slip distally whereas with longer balloon, potential of tricuspid leak or conduction block as it may impinge on adjacent structures. Potential advantage of Accura balloon over Tyshak balloon lies in its peculiar shape while inflation and variable diameter, making stepwise dilatation possible. Here, we report a case of successful balloon pulmonary valvuloplasty using Accura balloon (Vascular Concept, UK) with little modification of conventional technique. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Intra-gastric triacetin alters upper gastrointestinal motility in conscious dogs.

    PubMed

    Oosaka, Kazumasa; Tokuda, Masaaki; Furukawa, Naohiro

    2014-01-28

    To examine the effect of intra-gastric triacetin on both upper gastrointestinal motility and proximal gastric tone in conscious dogs. Three beagle dogs under sedation were surgically implanted with gastrocutaneous fistula in the gastric body and force transducers in the gastric antrum and duodenum. Beginning at week-2 after insertion, the animals were either fasted for 24 h or fed a liquid meal 2-3 h before the experiment. With the animals fully conscious, a polyethylene bag was inserted into the proximal stomach through the gastrocutaneous fistula, followed by 15 min of air inflation (minimal distending pressure of +2 mmHg) and then 20 mL of a low-, mid- or high-concentration triacetin solution (0.5%, 1.0% and 2.0%) or warm water (vehicle control). The proximal stomach receptive volume and gastric antral and duodenal contractions were measured over 10 min. The experiment was repeated twice per week over several months, with each animal receiving at least one infusion of the various triacetin solutions and the vehicle at different times. Intergroup differences were assessed by ANOVA and Bonferroni-Dunn post-hoc testing. Intra-gastric infusion of mid- and high-concentration triacetin induced an increase in the proximal stomach receptive volume, and the average increase induced by the high-concentration at 0-4 min after infusion was significantly greater than that induced by the vehicle control (62.4 ± 9.8 vs 18.4 ± 4.7, P < 0.01). The mid- and high-concentration triacetin also produced a temporary inhibition of the gastric antral contractions at 2 min after infusions; however, only the fasted group showed triacetin-induced antral contractile inhibition that was significantly greater than that in the vehicle control group (P < 0.05). In addition, only the fasted group showed a high-concentration triacetin-induced increase in duodenal contractions at 9-10 min that was significantly different from that in the vehicle control group (P < 0.05). Intra-gastric infusion

  4. Intra-gastric triacetin alters upper gastrointestinal motility in conscious dogs

    PubMed Central

    Oosaka, Kazumasa; Tokuda, Masaaki; Furukawa, Naohiro

    2014-01-01

    AIM: To examine the effect of intra-gastric triacetin on both upper gastrointestinal motility and proximal gastric tone in conscious dogs. METHODS: Three beagle dogs under sedation were surgically implanted with gastrocutaneous fistula in the gastric body and force transducers in the gastric antrum and duodenum. Beginning at week-2 after insertion, the animals were either fasted for 24 h or fed a liquid meal 2-3 h before the experiment. With the animals fully conscious, a polyethylene bag was inserted into the proximal stomach through the gastrocutaneous fistula, followed by 15 min of air inflation (minimal distending pressure of +2 mmHg) and then 20 mL of a low-, mid- or high-concentration triacetin solution (0.5%, 1.0% and 2.0%) or warm water (vehicle control). The proximal stomach receptive volume and gastric antral and duodenal contractions were measured over 10 min. The experiment was repeated twice per week over several months, with each animal receiving at least one infusion of the various triacetin solutions and the vehicle at different times. Intergroup differences were assessed by ANOVA and Bonferroni-Dunn post-hoc testing. RESULTS: Intra-gastric infusion of mid- and high-concentration triacetin induced an increase in the proximal stomach receptive volume, and the average increase induced by the high-concentration at 0-4 min after infusion was significantly greater than that induced by the vehicle control (62.4 ± 9.8 vs 18.4 ± 4.7, P < 0.01). The mid- and high-concentration triacetin also produced a temporary inhibition of the gastric antral contractions at 2 min after infusions; however, only the fasted group showed triacetin-induced antral contractile inhibition that was significantly greater than that in the vehicle control group (P < 0.05). In addition, only the fasted group showed a high-concentration triacetin-induced increase in duodenal contractions at 9-10 min that was significantly different from that in the vehicle control group (P < 0

  5. Hot-Air Ballooning in Physics Teaching.

    ERIC Educational Resources Information Center

    Haugland, Ole Anton

    1991-01-01

    Describes the modern hot-air balloon and the physics of ballooning. Proposes that students construct their own hot-air balloon and presents an experiment calculating the time needed for a balloon to rise to the ceiling of a gymnasium. (MDH)

  6. Optimum designs for superpressure balloons

    NASA Astrophysics Data System (ADS)

    Smith, M. S.; Rainwater, E. L.

    2004-01-01

    The elastica shape is now well known to be the best basic shape for superpressure balloon design. This shape, also known as the pumpkin, or natural shape for balloons, has been well understood since the early 1900s when it was applied to the determination of the shape of descending parachutes. The elastica shape was also investigated in the 1950s when high strength films were used to produce superpressure cylinder balloons. The need for uniform stress distribution in shells of early superpressure balloons led to a long period of the development of spherical superpressure balloons. Not until the late 1970s was the elastica shape revisited for the purpose of the producing superpressure balloons. This paper will review various development efforts in the field of superpressure design and will elaborate on the current state-of-the-art with suggestions for future developments.

  7. Flow Past a Descending Balloon

    NASA Technical Reports Server (NTRS)

    Baginski, Frank

    2001-01-01

    In this report, we present our findings related to aerodynamic loading of partially inflated balloon shapes. This report will consider aerodynamic loading of partially inflated inextensible natural shape balloons and some relevant problems in potential flow. For the axisymmetric modeling, we modified our Balloon Design Shape Program (BDSP) to handle axisymmetric inextensible ascent shapes with aerodynamic loading. For a few simple examples of two dimensional potential flows, we used the Matlab PDE Toolbox. In addition, we propose a model for aerodynamic loading of strained energy minimizing balloon shapes with lobes. Numerical solutions are presented for partially inflated strained balloon shapes with lobes and no aerodynamic loading.

  8. Status of the NASA Balloon Program

    NASA Technical Reports Server (NTRS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-01-01

    The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.

  9. Scientific ballooning in India Recent developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  10. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    NASA Technical Reports Server (NTRS)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  11. Intra-gastric pH following single oral administrations of rabeprazole and esomeprazole: double-blind cross-over comparison.

    PubMed

    Furuta, Kenji; Kohata, Yukie; Fujiwara, Yasuhiro; Sugimoto, Mitsushige; Uotani, Takahiro; Yamade, Mihoko; Sahara, Shu; Ichikawa, Hitomi; Furuta, Takahisa; Nio, Kenta; Iwakiri, Ryuichi; Inamori, Masahiko; Kawamura, Osamu; Kusano, Motoyasu; Kato, Mototsugu; Kawami, Noriyuki; Iwakiri, Katsuhiko; Takeuchi, Toshihisa; Higuchi, Kazuhide; Aimi, Masahito; Naora, Kohji; Fujimoto, Kazuma; Arakawa, Tetsuo; Kinoshita, Yoshikazu

    2014-11-01

    Comparisons between the acid inhibitory effects of rabeprazole and esomeprazole after single oral administration with standard doses have not been previously presented. We examined intra-gastric pH after oral administrations of these two proton pump inhibitors using 24-h pH monitoring. Fifty-four normal volunteers not infected by Helicobacter pylori were investigated. Using a cross-over design, we administered 10 mg of rabeprazole or 20 mg of esomeprazole in 27 at 30 min after supper and in the remaining 27 subjects at 15 min before supper, and performed 24-h pH monitoring. Intra-gastric pH data were nearly identical when the proton pump inhibitors were taken after meals. Even if the data were compared in different CYP2C19 genotypes, rabeprazole and esomeprazole did not show the difference. In poor metabolizer, both of the drugs showed stronger acid inhibition. When taken before meals, intra-gastric pH after esomeprazole administration was slightly but not significantly higher than that observed after rabeprazole administration not only in daytime but also in nighttime period. In conclusion, rabeprazole and esomeprazole were similarly effective when administered after a meal.

  12. A stress index model for ascending balloons

    NASA Technical Reports Server (NTRS)

    Smith, I. S.

    1986-01-01

    Attention is given to the development on the part of NASA of a simplified stress 'index' model to establish the relative stress magnitudes along a balloon's gore position as a function of altitude. Application of this model to several hundred balloon flights showed a good correlation between balloon failure rate and stress 'index' level. This model can be used during the balloon design process to lower the levels of stress in the balloon. By increasing the wall thickness of the balloon, adding caps, lengthening caps, or using external caps, lower stress can be accomplished. As a result, in January 1985, the NASA Balloon Program established a stress index specification to limit the design and flight stresses for NASA balloons.

  13. Mechanisms of intragastric pH sensing.

    PubMed

    Goo, Tyralee; Akiba, Yasutada; Kaunitz, Jonathan D

    2010-12-01

    Luminal amino acids and lack of luminal acidity as a result of acid neutralization by intragastric foodstuffs are powerful signals for acid secretion. Although the hormonal and neural pathways underlying this regulatory mechanism are well understood, the nature of the gastric luminal pH sensor has been enigmatic. In clinical studies, high pH, tryptic peptides, and luminal divalent metals (Ca(2+) and Mg(2+)) increase gastrin release and acid production. The calcium-sensing receptor (CaSR), first described in the parathyroid gland but expressed on gastric G cells, is a logical candidate for the gastric acid sensor. Because CaSR ligands include amino acids and divalent metals, and because extracellular pH affects ligand binding in the pH range of the gastric content, its pH, metal, and nutrient-sensing functions are consistent with physiologic observations. The CaSR is thus an attractive candidate for the gastric luminal sensor that is part of the neuroendocrine negative regulatory loop for acid secretion.

  14. Launching Garbage-Bag Balloons.

    ERIC Educational Resources Information Center

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  15. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    NASA Astrophysics Data System (ADS)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  16. Percutaneous Mitral Valve Dilatation: Single Balloon versus Double Balloon - A Finite Element Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schievano, Silvia; Kunzelman, Karyn; Nicosia, Mark

    2009-01-01

    Background: Percutaneous mitral valve (MV) dilatation is performed with either a single balloon (SB) or double balloon (DB) technique. The aim of this study was to compare the two balloon system results using the finite element (FE) method. Methods and Results: An established FE model of the MV was modified by fusing the MV leaflet edges at commissure level to simulate a stenotic valve (orifice area=180mm2). A FE model of a 30mm SB (low-pressure, elastomeric balloon) and an 18mm DB system (high-pressure, non-elastic balloon) was created. Both SB and DB simulations resulted in splitting of the commissures and subsequent stenosismore » dilatation (final MV area=610mm2 and 560mm2 respectively). Stresses induced by the two balloon systems varied across the valve. At the end of inflation, SB showed higher stresses in the central part of the leaflets and at the commissures compared to DB simulation, which demonstrated a more uniform stress distribution. The higher stresses in the SB analysis were due to the mismatch of the round balloon shape with the oval mitral orifice. The commissural split was not easily accomplished with the SB due to its high compliance. The high pressure applied to the DB guaranteed the commissural split even when high forces were required to break the commissure welds. Conclusions: The FE model demonstrated that MV dilatation can be accomplished by both SB and DB techniques. However, the DB method resulted in higher probability of splitting of the fused commissures and less damage caused to the MV leaflets by overstretching.« less

  17. Technologies developed by CNES balloon team

    NASA Astrophysics Data System (ADS)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  18. Retrieval of impacted broken balloon by balloon inflation in guiding catheter.

    PubMed

    Mehta, Vimal; Pandit, Bhagya Narayan; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay; Tyagi, Sanjay

    2014-07-01

    Broken catheter fragment in a coronary artery during percutaneous coronary angioplasty is a rare complication. It can result in serious problems as a result of thrombus formation and embolization of broken fragment. We report an unusual complication of a broken balloon catheter during angioplasty, which was successfully retrieved by balloon inflation in guiding catheter technique.

  19. Air Force Cambridge Research Laboratories balloon operations

    NASA Technical Reports Server (NTRS)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  20. Morphological characterization of selected balloon films and its effects on balloon performances

    NASA Technical Reports Server (NTRS)

    Said, Magdi A.

    1994-01-01

    Morphological characterization of several polyethylene balloon films have been studied using various techniques. The objective is to determine, if any, differentiating structural or morphological features that can be related to the performance of these balloon film materials. The results of the study indicate that the films are composed of either linear low denstiy polyethylene (LLDPE) or low density polyethylene (LDPE). A selective examination of these data imply that films limited degree of branching and larger crystallites size (same % crystallinity) showed good mechanical properties that appear to correlate with their high level of success in balloon flights.

  1. The EUSO-Balloon pathfinder

    NASA Astrophysics Data System (ADS)

    Adams, J. H.; Ahmad, S.; Albert, J.-N.; Allard, D.; Anchordoqui, L.; Andreev, V.; Anzalone, A.; Arai, Y.; Asano, K.; Ave Pernas, M.; Baragatti, P.; Barrillon, P.; Batsch, T.; Bayer, J.; Bechini, R.; Belenguer, T.; Bellotti, R.; Belov, K.; Berlind, A. A.; Bertaina, M.; Biermann, P. L.; Biktemerova, S.; Blaksley, C.; Blanc, N.; Błȩcki, J.; Blin-Bondil, S.; Blümer, J.; Bobik, P.; Bogomilov, M.; Bonamente, M.; Briggs, M. S.; Briz, S.; Bruno, A.; Cafagna, F.; Campana, D.; Capdevielle, J.-N.; Caruso, R.; Casolino, M.; Cassardo, C.; Castellinic, G.; Catalano, C.; Catalano, G.; Cellino, A.; Chikawa, M.; Christl, M. J.; Cline, D.; Connaughton, V.; Conti, L.; Cordero, G.; Crawford, H. J.; Cremonini, R.; Csorna, S.; Dagoret-Campagne, S.; de Castro, A. J.; De Donato, C.; de la Taille, C.; De Santis, C.; del Peral, L.; Dell'Oro, A.; De Simone, N.; Di Martino, M.; Distratis, G.; Dulucq, F.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Engel, R.; Falk, S.; Fang, K.; Fenu, F.; Fernández-Gómez, I.; Ferrarese, S.; Finco, D.; Flamini, M.; Fornaro, C.; Franceschi, A.; Fujimoto, J.; Fukushima, M.; Galeotti, P.; Garipov, G.; Geary, J.; Gelmini, G.; Giraudo, G.; Gonchar, M.; González Alvarado, C.; Gorodetzky, P.; Guarino, F.; Guzmán, A.; Hachisu, Y.; Harlov, B.; Haungs, A.; Hernández Carretero, J.; Higashide, K.; Ikeda, D.; Ikeda, H.; Inoue, N.; Inoue, S.; Insolia, A.; Isgrò, F.; Itow, Y.; Joven, E.; Judd, E. G.; Jung, A.; Kajino, F.; Kajino, T.; Kaneko, I.; Karadzhov, Y.; Karczmarczyk, J.; Karus, M.; Katahira, K.; Kawai, K.; Kawasaki, Y.; Keilhauer, B.; Khrenov, B. A.; Kim, J.-S.; Kim, S.-W.; Kim, S.-W.; Kleifges, M.; Klimov, P. A.; Kolev, D.; Kreykenbohm, I.; Kudela, K.; Kurihara, Y.; Kusenko, A.; Kuznetsov, E.; Lacombe, M.; Lachaud, C.; Lee, J.; Licandro, J.; Lim, H.; López, F.; Maccarone, M. C.; Mannheim, K.; Maravilla, D.; Marcelli, L.; Marini, A.; Martinez, O.; Masciantonio, G.; Mase, K.; Matev, R.; Medina-Tanco, G.; Mernik, T.; Miyamoto, H.; Miyazaki, Y.; Mizumoto, Y.; Modestino, G.; Monaco, A.; Monnier-Ragaigne, D.; Morales de los Ríos, J. A.; Moretto, C.; Morozenko, V. S.; Mot, B.; Murakami, T.; Murakami, M. Nagano; Nagata, M.; Nagataki, S.; Nakamura, T.; Napolitano, T.; Naumov, D.; Nava, R.; Neronov, A.; Nomoto, K.; Nonaka, T.; Ogawa, T.; Ogio, S.; Ohmori, H.; Olinto, A. V.; Orleański, P.; Osteria, G.; Panasyuk, M. I.; Parizot, E.; Park, I. H.; Park, H. W.; Pastircak, B.; Patzak, T.; Paul, T.; Pennypacker, C.; Perez Cano, S.; Peter, T.; Picozza, P.; Pierog, T.; Piotrowski, L. W.; Piraino, S.; Plebaniak, Z.; Pollini, A.; Prat, P.; Prévôt, G.; Prieto, H.; Putis, M.; Reardon, P.; Reyes, M.; Ricci, M.; Rodríguez, I.; Rodríguez Frías, M. D.; Ronga, F.; Roth, M.; Rothkaehl, H.; Roudil, G.; Rusinov, I.; Rybczyński, M.; Sabau, M. D.; Sáez-Cano, G.; Sagawa, H.; Saito, A.; Sakaki, N.; Sakata, M.; Salazar, H.; Sánchez, S.; Santangelo, A.; Santiago Crúz, L.; Sanz Palomino, M.; Saprykin, O.; Sarazin, F.; Sato, H.; Sato, M.; Schanz, T.; Schieler, H.; Scotti, V.; Segreto, A.; Selmane, S.; Semikoz, D.; Serra, M.; Sharakin, S.; Shibata, T.; Shimizu, H. M.; Shinozaki, K.; Shirahama, T.; Siemieniec-Oziȩbło, G.; Silva López, H. H.; Sledd, J.; Słomińska, K.; Sobey, A.; Sugiyama, T.; Supanitsky, D.; Suzuki, M.; Szabelska, B.; Szabelski, J.; Tajima, F.; Tajima, N.; Tajima, T.; Takahashi, Y.; Takami, H.; Takeda, M.; Takizawa, Y.; Tenzer, C.; Tibolla, O.; Tkachev, L.; Tokuno, H.; Tomida, T.; Tone, N.; Toscano, S.; Trillaud, F.; Tsenov, R.; Tsunesada, Y.; Tsuno, K.; Tymieniecka, T.; Uchihori, Y.; Unger, M.; Vaduvescu, O.; Valdés-Galicia, J. F.; Vallania, P.; Valore, L.; Vankova, G.; Vigorito, C.; Villaseñor, L.; von Ballmoos, P.; Wada, S.; Watanabe, J.; Watanabe, S.; Watts, J.; Weber, M.; Weiler, T. J.; Wibig, T.; Wiencke, L.; Wille, M.; Wilms, J.; Włodarczyk, Z.; Yamamoto, T.; Yamamoto, Y.; Yang, J.; Yano, H.; Yashin, I. V.; Yonetoku, D.; Yoshida, K.; Yoshida, S.; Young, R.; Zotov, M. Yu.; Zuccaro Marchi, A.

    2015-11-01

    EUSO-Balloon is a pathfinder for JEM-EUSO, the Extreme Universe Space Observatory which is to be hosted on-board the International Space Station. As JEM-EUSO is designed to observe Ultra-High Energy Cosmic Rays (UHECR)-induced Extensive Air Showers (EAS) by detecting their ultraviolet light tracks "from above", EUSO-Balloon is a nadir-pointing UV telescope too. With its Fresnel Optics and Photo-Detector Module, the instrument monitors a 50 km2 ground surface area in a wavelength band of 290-430 nm, collecting series of images at a rate of 400,000 frames/sec. The objectives of the balloon demonstrator are threefold: a) perform a full end-to-end test of a JEM-EUSO prototype consisting of all the main subsystems of the space experiment, b) measure the effective terrestrial UV background, with a spatial and temporal resolution relevant for JEM-EUSO. c) detect tracks of ultraviolet light from near space for the first time. The latter is a milestone in the development of UHECR science, paving the way for any future space-based UHECR observatory. On August 25, 2014, EUSO-Balloon was launched from Timmins Stratospheric Balloon Base (Ontario, Canada) by the balloon division of the French Space Agency CNES. From a float altitude of 38 km, the instrument operated during the entire astronomical night, observing UV-light from a variety of ground-covers and from hundreds of simulated EASs, produced by flashers and a laser during a two-hour helicopter under-flight.

  2. Analysis of the meal-dependent intragastric performance of a gastric-retentive tablet assessed by magnetic resonance imaging.

    PubMed

    Steingoetter, A; Kunz, P; Weishaupt, D; Mäder, K; Lengsfeld, H; Thumshirn, M; Boesiger, P; Fried, M; Schwizer, W

    2003-10-01

    Modern medical imaging modalities can trace labelled oral drug dosage forms in the gastrointestinal tract, and thus represent important tools for the evaluation of their in vivo performance. The application of gastric-retentive drug delivery systems to improve bioavailability and to avoid unwanted plasma peak concentrations of orally administered drugs is of special interest in clinical and pharmaceutical research. To determine the influence of meal composition and timing of tablet administration on the intragastric performance of a gastric-retentive floating tablet using magnetic resonance imaging in the sitting position. A tablet formulation was labelled with iron oxide particles as negative magnetic resonance contrast marker to allow the monitoring of the tablet position in the food-filled human stomach. Labelled tablet was administered, together with three different solid meals, to volunteers seated in a 0.5-T open-configuration magnetic resonance system. Volunteers were followed over a 4-h period. Labelled tablet was detectable in all subjects throughout the entire study. The tablet showed persistent good intragastric floating performance independent of meal composition. Unfavourable timing of tablet administration had a minor effect on the intragastric tablet residence time and floating performance. Magnetic resonance imaging can reliably monitor and analyse the in vivo performance of labelled gastric-retentive tablets in the human stomach.

  3. Two Tethered Balloon Systems

    NASA Technical Reports Server (NTRS)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  4. Mobile, high-wind, balloon-launching apparatus

    NASA Technical Reports Server (NTRS)

    Rust, W. David; Marshall, Thomas C.

    1989-01-01

    In order to place instruments for measuring meteorological and electrical parameters into thunderstorms, an inexpensive apparatus has been developed which makes it possible to inflate, transport, and launch balloons in high winds. The launching apparatus is a cylinder of bubble plastic that is made by joining the sides of the cylinder together with a velcro rip strip. A balloon is launched by pulling the rip strip rapidly. This allows the balloon to pop upward into the ambient low-level wind and carry its instrumentation aloft. Different-sized launch tubes are constructed to accommodate particular sizes of balloons. Balloons have been launched in winds of about 20 m/s.

  5. Universal stratospheric balloon gradiometer

    NASA Astrophysics Data System (ADS)

    Tsvetkov, Yury; Filippov, Sergey; Brekhov, Oleg; Nikolaev, Nikolay

    The study of the interior structure of the Earth and laws of its evolution is one of the most difficult problems of natural science. Among the geophysical fields the anomaly magnetic field is one of the most informational in questions of the Earth’s crust structure. Many important parameters of an environment are expedient for measuring at lower altitudes, than satellite ones. So, one of the alternatives is stratospheric balloon survey. The balloon flight altitudes cover the range from 20 to 50 km. At such altitudes there are steady zone air flows due to which the balloon flight trajectories can be of any direction, including round-the-world (round-the-pole). For investigation of Earth's magnetic field one of the examples of such sounding system have been designed, developed and maintained at IZMIRAN and MAI during already about 25 years. This system consists of three instrumental containers uniformly placed along a vertical 6 km line. Up today this set has been used only for geomagnetic purposes. So we describe this system on example of the measuring of the geomagnetic field gradient. System allows measuring a module and vertical gradient of the geomagnetic field along the whole flight trajectory and so one’s name is - stratospheric balloon magnetic gradiometer (SMBG). The GPS-receivers, located in each instrumental container, fix the flight coordinates to within several tens meters. Process of SBMG deployment, feature of the exit of rope from the magazine at the moment of balloon launching has been studied. Used magazine is cellular type. The hodograph of the measuring base of SBMG and the technique of correction of the deviations of the measuring base from the vertical line (introduction of the amendments for the deviation) during the flight have been investigated. It is shown that estimation of the normal level of values of the vertical gradient of the geomagnetic field is determined by the accuracy of determining the length of the measuring base SBMG

  6. The effect of orally administered ranitidine and once-daily or twice-daily orally administered omeprazole on intragastric pH in cats.

    PubMed

    Šutalo, S; Ruetten, M; Hartnack, S; Reusch, C E; Kook, P H

    2015-01-01

    Gastric acid suppressants frequently are used in cats with acid-related gastric disorders. However, it is not known if these drugs effectively increase intragastric pH in cats. To examine the effects of PO administered ranitidine and omeprazole on intragastric pH in cats and to compare the efficacy of once-daily versus twice-daily dosage regimens for omeprazole. Eight domestic shorthair cats. Using a randomized 4-way cross-over design, cats were given enteric-coated omeprazole granules (1.1-1.3 mg/kg q24h and q12h), ranitidine (1.5-2.3 mg/kg q12h), and placebo. Intragastric pH was monitored continuously for 96 hours using the Bravo(™) system, starting on day 4 of treatment, followed by a median washout period of 12 days. Mean percentage of time pH was ≥3 and ≥4 was compared among groups using repeated measures ANOVA. Mean ± SD percentage of time intragastric pH was ≥3 and ≥4 was 67.0 ± 24.0% and 54.6 ± 26.4% for twice-daily omeprazole, 24.4 ± 22.8% and 16.8 ± 19.3% for once-daily omeprazole, 16.5 ± 9.0% and 9.6 ± 5.9% for ranitidine, and 9.4 ± 8.0% and 7.0 ± 6.6% for placebo administration. Twice-daily omeprazole treatment significantly increased intragastric pH, whereas pH after once-daily omeprazole and ranitidine treatments did not differ from that of placebo-treated cats. Only twice-daily PO administered omeprazole significantly suppressed gastric acidity in healthy cats, whereas once-daily omeprazole and standard dosages of ranitidine were not effective acid suppressants in cats. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.

  7. The Great Balloon Controversy.

    ERIC Educational Resources Information Center

    Chase, Valerie

    1989-01-01

    Discusses the harmful effects of balloon launches and the dumping of plastic debris into oceans. Cites several examples of plastic materials being discovered inside the bodies of sick and/or dead marine animals. Offers alternative activities to releasing balloons into the atmosphere. (RT)

  8. Current trends of balloon laryngoplasty in Thailand.

    PubMed

    Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave

    2017-06-01

    To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.

  9. Esomeprazole 40 mg provides improved intragastric acid control as compared with lansoprazole 30 mg and rabeprazole 20 mg in healthy volunteers.

    PubMed

    Wilder-Smith, Clive H; Röhss, Kerstin; Nilsson-Pieschl, Catharina; Junghard, Ola; Nyman, Lars

    2003-01-01

    To compare the effects of standard-dose esomeprazole with those of standard doses of lansoprazole and rabeprazole on intragastric pH during repeated daily oral dosing in healthy volunteers. In two standardized, randomized crossover studies, Helicobacter pylori negative healthy volunteers (study A: 19 males, 5 females; study B: 13 males, 10 females) received esomeprazole 40 mg and either lansoprazole 30 mg (study A) or rabeprazole 20 mg (study B) orally once daily in the morning for 5 days. Continuous 24-hour intragastric pH recording was performed on day 5. The intragastric pH was maintained >4 for 65% (95% CI 59.5-71.3) of the 24-hour period with esomeprazole and for 53% of the time (95% CI 47.0-58.9) with lansoprazole in study A (p < 0.001). In study B, the proportion of time with pH >4 was 61% (95% CI 53.6-68.3) with esomeprazole versus 45% (95% CI 37.7-52.5) with rabeprazole (p = 0.005). The 24-hour median pH and the proportion of volunteers with intragastric pH >4 for > or =12 h and > or =16 h were significantly higher with esomeprazole than with either lansoprazole or rabeprazole. Esomeprazole 40 mg provides significantly more effective and more sustained gastric acid control than lansoprazole 30 mg or rabeprazole 20 mg in healthy volunteers. Copyright 2003 S. Karger AG, Basel

  10. Reference level winds from balloon platforms

    NASA Technical Reports Server (NTRS)

    Lally, Vincent E.

    1985-01-01

    The superpressure balloon was developed to provide a method of obtaining global winds at all altitudes from 5 to 30 km. If a balloon could be made to fly for several weeks at a constant altitude, and if it could be tracked accurately on its global circuits, the balloon would provide a tag for the air parcel in which it was embedded. The Lagrangian data on the atmospheric circulation would provide a superior data input to the numerical model. The Global Atmospheric Research Program (GARP) was initiated in large part based on the promise of this technique coupled with free-floating ocean buoys and satellite radiometers. The initial name proposed by Charney for GARP was SABABURA 'SAtellite BAlloon BUoy RAdiometric system' (Charney, 1966). However, although the superpressure balloon exceeded its designers' expectations for flight duration in the stratosphere (longest flight duration of 744 days), flight duration below 10 km was limited by icing in super-cooled clouds to a few days. The balloon was relegated to a secondary role during the GARP Special Observing Periods. The several major superpressure balloon programs for global wind measurement are described as well as those new developments which make the balloon once again an attractive vehicle for measurement of global winds as a reference and bench-mark system for future satellite systems.

  11. Modelling Hot Air Balloons.

    ERIC Educational Resources Information Center

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  12. Intragastric Gelation of Heated Soy Protein Isolate-Alginate Mixtures and Its Effect on Sucrose Release.

    PubMed

    Huang, Zhaozhi; Gruen, Ingolf; Vardhanabhuti, Bongkosh

    2018-06-15

    The goal of our study was to investigate the effect of alginate on in vitro gastric digestion and sucrose release of soy protein isolate (SPI) in model beverages. Model beverages containing 5% w/w SPI, 0% to 0.20% w/w alginate, and 10% w/w sucrose were prepared by heating the mixtures at 85 °C for 30 min at pH 6.0 or 7.0. Characterizations of beverages included determination of zeta potential, particle size and rheological properties. Digestion patterns and sucrose release profiles were determined during 2 hr in vitro gastric digestion using SDS-PAGE and HPLC analysis, respectively. Increasing alginate concentration led to increased negative surface charge, particle size, as well as viscosity and pseudoplastic behavior; however, no phase separation was observed. SPI beverages formed intragastric gel during in vitro gastric digestion when the formulations contained alginate or at pH 6.0 without alginate. Formation of the intragastric gel led to delayed protein digestion and release of sucrose. Higher resistance to digestion and a slower sucrose release rate were exhibited at increased alginate concentration, and to a lesser extent, at pH 6.0. This suggests that electrostatic interaction between SPI and alginate that occurred when the beverages were under gastric condition could be responsible for the intragastric gelation. These results could potentially lead to the formulation of SPI beverages with functionality to lower postprandial glycemic response. The results could be used to design beverages or semi solid food products with altered digestion properties and lowered or slower glucose release. © 2018 Institute of Food Technologists®.

  13. Balloon-augmented Onyx embolization of cerebral arteriovenous malformations using a dual-lumen balloon: a multicenter experience.

    PubMed

    Spiotta, Alejandro M; James, Robert F; Lowe, Stephen R; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Bhalla, Tarun; Janjua, Rashid M; Delaney, John J; Quintero-Wolfe, Stacey; Turner, Raymond D

    2015-10-01

    Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate 'proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges. Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen. Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.3±1.6 cm). Mean fluoroscopy time for each procedure was 48±26 min (28 min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment. This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Solar research with stratospheric balloons

    NASA Astrophysics Data System (ADS)

    Vázquez, Manuel; Wittmann, Axel D.

    Balloons, driven by hot air or some gas lighter than air, were the first artificial machines able to lift payloads (including humans) from the ground. After some pioneering flights the study of the physical properties of the terrestrial atmosphere constituted the first scientific target. A bit later astronomers realized that the turbulence of the atmospheric layers above their ground-based telescopes deteriorated the image quality, and that balloons were an appropriate means to overcome, total or partially, this problem. Some of the most highly-resolved photographs and spectrograms of the sun during the 20th century were actually obtained by balloon-borne telescopes from the stratosphere. Some more recent projects of solar balloon astronomy will also be described.

  15. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  16. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  17. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  18. Calculating Payload for a Tethered Balloon System

    Treesearch

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  19. Flight Qualification of the NASA's Super Pressure Balloon

    NASA Astrophysics Data System (ADS)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  20. Hypotensive and neurometabolic effects of intragastric Reishi (Ganoderma lucidum) administration in hypertensive ISIAH rat strain.

    PubMed

    Shevelev, Oleg B; Seryapina, Alisa A; Zavjalov, Evgenii L; Gerlinskaya, Lyudmila A; Goryachkovskaya, Tatiana N; Slynko, Nikolay M; Kuibida, Leonid V; Peltek, Sergey E; Markel, Arcady L; Moshkin, Mikhail P

    2018-03-01

    As the standard clinically used hypotensive medicines have many undesirable side effects, there is a need for new therapeutic agents, especially ones of a natural origin. One possible candidate is extract from the mushroom Reishi (Ganoderma lucidum), which is used in the treatment and prevention of many chronic diseases. To study the effectiveness of Reishi, which grows in the Altai Mountains, as an antihypertensive agent, we intragastrically administered Reishi water extract to adult male hypertensive ISIAH (inherited stress-induced arterial hypertension) rats. After seven weeks, Reishi therapy reduced blood pressure in experimental animals at a level comparable to that of losartan. Unlike losartan, intragastric Reishi introduction significantly increases cerebral blood flow and affects cerebral cortex metabolic patterns, shifting the balance of inhibitory and excitatory neurotransmitters toward excitation. Changes in cerebral blood flow and ratios of neurometabolites suggests Reishi has a potential nootropic effect. Copyright © 2018 Elsevier GmbH. All rights reserved.

  1. Early Cosmic Ray Research with Balloons

    NASA Astrophysics Data System (ADS)

    Walter, Michael

    2013-06-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  2. History and perspectives of scientific ballooning

    NASA Astrophysics Data System (ADS)

    Lefevre, Frank

    2001-08-01

    Prehistory: Robertson, Biot and Gay-Lussac; Glaisher and the first studies of the atmosphere; Flammarion. The rebirth of scientific ballooning: polyethylene and mylar vehicles at Minneapolis. Super-pressurized balloons. The CNES and the Nasa programs; meteorology, aeronomy and astronomy, The Eole program. The Venus and Mars balloons in the French-Soviet space program. The future.

  3. Effects of rabeprazole, 20 mg, or esomeprazole, 20 mg, on 24-h intragastric pH and serum gastrin in healthy subjects.

    PubMed

    Warrington, S; Baisley, K; Boyce, M; Tejura, B; Morocutti, A; Miller, N

    2002-07-01

    To compare the antisecretory effects of rabeprazole and esomeprazole in an open, randomized, two-way crossover, clinical pharmacology study. Twenty-four healthy subjects (14 men, 10 women; mean age 26.8 years) received rabeprazole 20 mg or esomeprazole 20 mg daily on days 1-5, with a 14-day 'wash-out'. Intragastric pH was recorded continuously, and serum gastrin measured, on days 0, 1 and 5. On day 0, mean intragastric pH AUC was significantly higher before the esomeprazole than before the rabeprazole treatment in four of the five time intervals analysed. On days 1 and 5, mean intragastric pH AUC was higher after rabeprazole than esomeprazole during 5-11, 14-24 and 0-24 h after dosing. Mean pH AUC in the first 5 h after dosing on day 5 was higher after esomeprazole than rabeprazole (P=0.012). On day 1, mean per cent times pH > 3 and > 4 were significantly greater after rabeprazole than esomeprazole during 0-14, 14-24 and 0-24 h. On day 5, mean serum gastrin AUC0-4 was higher (P = 0.017) after rabeprazole than esomeprazole (335 vs. 316 pg/mL.h). In this clinical pharmacology study, rabeprazole 20 mg daily was more effective than esomeprazole 20 mg daily in increasing intragastric pH and maintaining pH > 3 and > 4. On day 5, mean pH AUC was higher after esomeprazole than rabeprazole.

  4. Histopathology of balloon-dilation Eustachian tuboplasty.

    PubMed

    Kivekäs, Ilkka; Chao, Wei-Chieh; Faquin, William; Hollowell, Monica; Silvola, Juha; Rasooly, Tali; Poe, Dennis

    2015-02-01

    Surgical intervention of the Eustachian tube (ET) has become increasingly common in the past decade, and balloon dilation has shown promising results in recent studies. It is unclear how balloon dilation enhances ET function. Our aim was to evaluate histological changes in the ET's mucosal lumen comparing before balloon dilation, immediately after, and postoperatively. Case series. Thirteen patients with bilateral ET dysfunction were enrolled. Biopsies of the ET mucosa were obtained just before balloon dilation; immediately after; and in three cases, 5 to 12 weeks postoperatively. Specimens were retrospectively examined under light microscopy by two pathologists blinded to the clinical information and whether specimens were pre- or postballoon dilation. Preoperative biopsies were characterized by inflammatory changes within the epithelium and submucosal layer. Immediate response to balloon dilation was thinning of the mucosa, shearing of epithelium and crush injury to the submucosa, especially to lymphocytic infiltrates. Postoperative biopsies demonstrated healthy pseudocolumnar epithelium and replacement of lymphocytic infiltrate with a thinner layer of fibrous tissue. Reduction of inflammatory epithelial changes and submucosal inflammatory infiltrate appeared to be the principal result of balloon dilation. The balloon may shear or crush portions of inflamed epithelium but usually spared the basal layer, allowing for rapid healing. Additionally, it appeared to effectively crush lymphocytes and lymphocytic follicles that may become replaced with thinner fibrous scar. Histopathology of the ET undergoing balloon dilation demonstrated effects that could reduce the overall inflammatory burden and may contribute to clinical improvement in ET function. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    PubMed

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  6. NASA balloon design and flight - Philosophy and criteria

    NASA Technical Reports Server (NTRS)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  7. Long-Duration Altitude-Controlled Balloons for Venus: A Feasibility Study Informed by Balloon Flights in Remote Environments on Earth

    NASA Astrophysics Data System (ADS)

    Voss, P. B.; Nott, J.; Cutts, J. A.; Hall, J. L.; Beauchamp, P. M.; Limaye, S. S.; Baines, K. H.; Hole, L. R.

    2013-12-01

    In situ exploration of the upper atmosphere of Venus, approximately 65-77 km altitude, could answer many important questions (Limaye 2013, Crisp 2013). This region contains a time-variable UV absorber of unknown composition that controls many aspects of the heat balance on Venus. Understanding the composition and dynamics of this unknown absorber is an important science goal; in situ optical and chemical measurements are needed. However, conventional approaches do not provide access to this altitude range, repeated traverses, and a mission lifetime of several months needed to effectively carry out the science. This paper examines concepts for altitude-controlled balloons not previously flown on planetary missions that could potentially provide the desired measurements. The concepts take advantage of the fact that at 60 km altitude, for example, the atmospheric density on Venus is about 40% of the sea-level density on earth and the temperature is a moderate 230 K. The solar flux is approximately double that on earth, creating some thermal challenges, but making photovoltaic power highly effective. Using a steady-state thermodynamic model and flight data from Earth, we evaluate the suitability of two types of altitude-controlled balloons for a potential mission on Venus. Such balloons could repeatedly measure profiles, avoid diurnal temperature extremes, and navigate using wind shear. The first balloon design uses air ballast (AB) whereby ambient air can be compressed into or released from a constant-volume balloon, causing it to descend or ascend accordingly. The second design uses lift-gas compression (LGC) to change the volume of a zero-pressure balloon, thereby changing its effective density and altitude. For an altitude range of 60-75 km on Venus, we find that the superpressure volume for a LGC balloon is about 5% of that needed for an AB balloon while the maximum pressurization is the same for both systems. The compressor work per km descent of the LGC balloon

  8. Septotomy and Balloon Dilation to Treat Chronic Leak After Sleeve Gastrectomy: Technical Principles.

    PubMed

    Campos, Josemberg Marins; Ferreira, Flávio Coelho; Teixeira, André F; Lima, Jones Silva; Moon, Rena C; D'Assunção, Marco Aurélio; Neto, Manoel Galvão

    2016-08-01

    Scientific, MA, USA) insertion. The balloon catheter must be firmly held during gradual inflation (maximum 10 psi) to avoid slippage and laceration. This allows increasing the gastric lumen. (6) Septotomy by electrocautery with a needle knife (Boston Scientific, MA, USA) can be made when an intensive fibrotic septum is present; bleeding is rare in this case. In this case, the endoclip previously used was removed from the septum with forceps to avoid heat transmission. Small staples visualized in the fistula orifice were not completely removed due to technical difficulties and friable tissue. Two sessions were performed in 15 days, resulting in leak closure. The patient was submitted to radiological control 1 week after the second session, which revealed fistula healing, without gastric stenosis. The nasoduodenal feeding tube remained for 7 days, when the patient started oral diet. This patient was followed for 18 months without recurrence. Septotomy and balloon dilation were initially performed on a difficult-to-treat chronic fistula after gastric bypass and named before as stricturotomy (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007). This procedure allows internal drainage of the fistula and deviates oral intake to the pouch. In addition, achalasia balloon dilation treats strictures and axis deviation of the gastric chamber, promoting reduction of the intragastric pressure. Septotomy and balloon dilation are technically feasible and might be useful in selected cases for closure of chronic leaks after LSG.

  9. Power supplies for long duration balloon flights

    NASA Astrophysics Data System (ADS)

    Lichfield, Ernest W.

    Long duration balloon flights require more electrical power than can be carried in primary batteries. This paper provides design information for selecting rechargeable batteries and charging systems. Solar panels for recharging batteries are discussed, with particular emphasis on cells mounting suitable for balloon flights and panel orientation for maximum power collection. Since efficient utilization of power is so important, modern DC to DC power conversion techniques are presented. On short flights of 1 day or less, system designers have not been greatly concerned with battery weight. But, with the advent of long duration balloon flights using superpressure balloons, anchor balloon systems, and RACOON balloon techniques, power supplies and their weight become of prime importance. The criteria for evaluating power systems for long duration balloon flights is performance per unit weight. Instrumented balloon systems have flown 44 days. For these very long duration flights, batteries recharged from solar cells are the only solution. For intermediate flight duration, say less than 10 days, the system designer should seriously consider using primary cells. The National Center for Atmospheric Research is sponsored by the National Science Foundation. Any opinions, findings and conclusions or recommendations expressed in this publication are those of the authors and do not necessarily reflect the views of the National Science Foundation.

  10. Gondola development for CNES stratospheric balloons

    NASA Astrophysics Data System (ADS)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  11. Effects of Intragastric and Intravenous Sodium Bicarbonate on Rate of Recovery from Post-asphyxial Acidosis in the Neonate

    PubMed Central

    Evans, R. S.; Olver, R. E.; Appleyard, W. J.; Newman, C. G. H.

    1970-01-01

    A trial was carried out on acidotic infants recovering from neonatal asphyxia, on the relative effects of intragastric and intravenous sodium bicarbonate on acid/base balance. Intragastric bicarbonate caused an increased rate of correction of metabolic acidosis within 30 minutes of administration. However, the Pco2 remained higher in these patients than in the controls, so that the effect of the bicarbonate on rate of pH correction was negligible. The rise in Pco2 occurred despite apparently normal respiratory function. A similar limitation of pH rise by a sustained rise in Pco2 was evident in the intravenously treated patients. Treatment of metabolic acidosis in neonates with sodium bicarbonate may not produce the desired correction of pH. PMID:5427844

  12. Behavioral Effects and Pharmacokinetics of (±)-3,4-Methylenedioxymethamphetamine (MDMA, Ecstasy) after Intragastric Administration to Baboons

    PubMed Central

    Goodwin, Amy K.; Mueller, Melanie; Shell, Courtney D.; Ricaurte, George A.

    2013-01-01

    (±)-3,4-Methylenedioxymethamphetamine (MDMA, “Ecstasy”) is a popular drug of abuse. We aimed to characterize the behavioral effects of intragastric MDMA in a species closely related to humans and to relate behavioral effects to plasma MDMA and metabolite concentrations. Single doses of MDMA (0.32–7.8 mg/kg) were administered via an intragastric catheter to adult male baboons (N = 4). Effects of MDMA on food-maintained responding were assessed over a 20-hour period, whereas untrained behaviors and fine-motor coordination were characterized every 30 minutes until 3 hours postadministration. Levels of MDMA and metabolites in plasma were measured in the same animals (n = 3) after dosing on a separate occasion. MDMA decreased food-maintained responding over the 20-hour period, and systematic behavioral observations revealed increased frequency of bruxism as the dose of MDMA was increased. Drug blood level determinations showed no MDMA after the lower doses of MDMA tested (0.32–1.0 mg/kg) and modest levels after higher MDMA doses (3.2–7.8 mg/kg). High levels of 3,4-dihydroxymethamphetamine (HHMA) were detected after all doses of MDMA, suggesting extensive first-pass metabolism of MDMA in the baboon. The present results demonstrate that MDMA administered via an intragastric catheter produced behavioral effects that have also been reported in humans. Similar to humans, blood levels of MDMA after oral administration may not be predictive of the behavioral effects of MDMA. Metabolites, particularly HHMA, may play a significant role in the behavioral effects of MDMA. PMID:23516331

  13. Behavioral effects and pharmacokinetics of (±)-3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) after intragastric administration to baboons.

    PubMed

    Goodwin, Amy K; Mueller, Melanie; Shell, Courtney D; Ricaurte, George A; Ator, Nancy A

    2013-06-01

    (±)-3,4-Methylenedioxymethamphetamine (MDMA, "Ecstasy") is a popular drug of abuse. We aimed to characterize the behavioral effects of intragastric MDMA in a species closely related to humans and to relate behavioral effects to plasma MDMA and metabolite concentrations. Single doses of MDMA (0.32-7.8 mg/kg) were administered via an intragastric catheter to adult male baboons (N = 4). Effects of MDMA on food-maintained responding were assessed over a 20-hour period, whereas untrained behaviors and fine-motor coordination were characterized every 30 minutes until 3 hours postadministration. Levels of MDMA and metabolites in plasma were measured in the same animals (n = 3) after dosing on a separate occasion. MDMA decreased food-maintained responding over the 20-hour period, and systematic behavioral observations revealed increased frequency of bruxism as the dose of MDMA was increased. Drug blood level determinations showed no MDMA after the lower doses of MDMA tested (0.32-1.0 mg/kg) and modest levels after higher MDMA doses (3.2-7.8 mg/kg). High levels of 3,4-dihydroxymethamphetamine (HHMA) were detected after all doses of MDMA, suggesting extensive first-pass metabolism of MDMA in the baboon. The present results demonstrate that MDMA administered via an intragastric catheter produced behavioral effects that have also been reported in humans. Similar to humans, blood levels of MDMA after oral administration may not be predictive of the behavioral effects of MDMA. Metabolites, particularly HHMA, may play a significant role in the behavioral effects of MDMA.

  14. Endovascular balloon-assisted embolization of intracranial and cervical arteriovenous malformations using dual-lumen coaxial balloon microcatheters and Onyx: initial experience.

    PubMed

    Jagadeesan, Bharathi D; Grigoryan, Mikayel; Hassan, Ameer E; Grande, Andrew W; Tummala, Ramachandra P

    2013-12-01

    Ethylene vinyl alcohol copolymer (Onyx) is widely used for the embolization of arteriovenous malformations (AVMs) of the brain, head, and neck. Balloon-assisted Onyx embolization may provide additional unique advantages in the treatment of AVMs in comparison with traditional catheter-based techniques. To report our initial experience in performing balloon-assisted AVM embolization for brain and neck AVMs with the use of the new Scepter-C and Scepter-XC coaxial dual-lumen balloon microcatheters. Balloon-assisted transarterial embolization was performed in a series of 7 patients with AVMs (4 with brain AVMs, 1 with a dural arteriovenous fistula, and 2 with neck AVMs) by using Onyx delivered through the lumen of Scepter-C or Scepter XC coaxial balloon microcatheters. Following the initial balloon-catheter navigation into a feeding artery and the subsequent inflation of the balloon, the embolization was performed by using Onyx 18, Onyx 34, or both. A total of 12 embolization sessions were performed via 17 arterial feeders in these 7 patients. In 1 patient, there was an arterial perforation from the inflation of the balloon; in all others, the embolization goals were successfully achieved with no adverse events. The balloon microcatheters showed excellent navigability, and there were no problems with retrieval or with the repeated inflation and deflation of the balloons. A proximal Onyx plug, which is crucial in many AVM embolizations, was not necessary with this technique. Additionally, fluoroscopy and procedural times seemed lower with this technique compared with conventional embolization methods.

  15. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    PubMed

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  16. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  17. Study of the allergenic potential of Bacillus thuringiensis Cry1Ac toxin following intra-gastric administration in a murine model of food-allergy.

    PubMed

    Santos-Vigil, Karla I; Ilhuicatzi-Alvarado, Damaris; García-Hernández, Ana L; Herrera-García, Juan S; Moreno-Fierros, Leticia

    2018-06-07

    Cry1Ac toxin, from Bacillus thuringiensis, is widely used as a biopesticide and expressed in genetically modified (GM) plants used for human and animal consumption. Since Cry1Ac is also immunogenic and able to activate macrophages, it is crucial to thoroughly evaluate the immunological effects elicited after intra-gastric administration. The allergenic potential of purified Cry1Ac was assessed and compared with that induced in a murine model of food-allergy to ovalbumin (OVA), in which animals are sensitized with the adjuvant Cholera toxin (CT). Mice were weekly intragastrically administered with: i) vehicle phosphate-buffered saline (PBS), ii) OVA, iii) OVA plus CT iv) Cry1Ac or v) OVA plus Cry1Ac. Seven weeks after, mice were intragastrically challenged and allergic reactions along with diverse allergy related immunological parameters were evaluated at systemic and intestinal level. The groups immunized with, Cry1Ac, OVA/Cry1Ac or OVA/CT developed moderate allergic reactions, induced significant IgE response and increased frequencies of intestinal granulocytes, IgE+ eosinophils and IgE+ lymphocytes. These same groups also showed colonic lymphoid hyperplasia, notably in humans, this has been associated with food allergy and intestinal inflammation. Although the adjuvant and allergenic potential of CT were higher than the effects of Cry1Ac, the results show that applied intra-gastrically at 50 μg doses, Cry1Ac is immunogenic, moderately allergenic and able to provoke intestinal lymphoid hyperplasia. Moreover, Cry1Ac is also able to induce anaphylaxis, since when mice were intragastrically sensitized with increasing doses of Cry1Ac, with every dose tested, a significant drop in rectal temperature was recorded after intravenous challenge. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Balloon Ascent: 3-D Simulation Tool for the Ascent and Float of High-Altitude Balloons

    NASA Technical Reports Server (NTRS)

    Farley, Rodger E.

    2005-01-01

    The BalloonAscent balloon flight simulation code represents a from-scratch development using Visual Basic 5 as the software platform. The simulation code is a transient analysis of balloon flight, predicting the skin and gas temperatures along with the 3-D position and velocity in a time and spatially varying environment. There are manual and automated controls for gas valving and the dropping of ballast. Also, there are many handy calculators, such as appropriate free lift, and steady-state thermal solutions with temperature gradients. The strength of this simulation model over others in the past is that the infrared environment is deterministic rather than guessed at. The ground temperature is specified along with the emissivity, which creates a ground level IR environment that is then partially absorbed as it travels upward through the atmosphere to the altitude of the balloon.

  19. Efficacy of primed infusions with high dose ranitidine and omeprazole to maintain high intragastric pH in patients with peptic ulcer bleeding: a prospective randomised controlled study.

    PubMed Central

    Labenz, J; Peitz, U; Leusing, C; Tillenburg, B; Blum, A L; Börsch, G

    1997-01-01

    BACKGROUND: In healthy subjects, continuous infusions of high dose ranitidine and omeprazole produce high intragastric pH values. AIM: To test the hypothesis that both drugs also maintain high intragastric pH values in patients with bleeding ulcers. PATIENTS AND METHODS: In two parallel studies, 20 patients with bleeding duodenal ulcers and 20 patients with bleeding gastric ulcers were randomly assigned to receive either ranitidine (0.25 mg/kg/hour after a bolus of 50 mg) or omeprazole (8 mg/hour after a bolus of 80 mg) for 24 hours. Intragastric pH was continuously recorded with a glass electrode placed 5 cm below the cardia. RESULTS: Both drugs rapidly raised the intragastric pH above 6. During the second 12 hour period, however, the percentage of time spent below a pH of 6 was 0.15% with omeprazole and 20.1% with ranitidine (p = 0.0015) in patients with duodenal ulcer; in patients with gastric ulcer it was 0.1% with omeprazole and 46.1% with ranitidine (p = 0.002). CONCLUSIONS: Primed infusions of omeprazole after a bolus produced consistently high intragastric pH values in patients with bleeding peptic ulcers, whereas primed infusions with ranitidine were less effective during the second half of a 24 hour treatment course. This loss of effectiveness may be due to tolerance. PMID:9155573

  20. Meeting the Challenge to Balloon Science

    NASA Astrophysics Data System (ADS)

    Jones, W. Vernon

    The promise of superpressure ballooning is helping the balloon program evolve toward a cost-effective means for frequent access to near-space. Superpressure balloons fabricated from strong, light-weight composite materials have the potential for increasing flight times of ton-class payloads to 100 days or more at altitudes above 5 mbars at essentially any geographic latitude. Although this new capability is still in an embryonic stage, its potential has already had an impact. Specifically, a new NASA Office of Space Science policy for University-class Explorer missions allows balloon investigations to compete on an equal basis with other low-cost missions requiring expendable launch vehicles. The new challenge for the science community is to design winning payloads that can be built within the cost cap of $13 M, including launch costs, and be developed within two to three years from selection to launch. Defining the international trajectories and getting the overflight agreements for balloon flights that make several circumnavigations of Earth will also be a challenge

  1. The French balloon and sounding rocket space program

    NASA Astrophysics Data System (ADS)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  2. TMBM: Tethered Micro-Balloons on Mars

    NASA Technical Reports Server (NTRS)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  3. Advances in Scientific Balloon Thermal Modeling

    NASA Technical Reports Server (NTRS)

    Bohaboj, T.; Cathey, H. M., Jr.

    2004-01-01

    The National Aeronautics and Space Administration's Balloon Program office has long acknowledged that the accurate modeling of balloon performance and flight prediction is dependant on how well the balloon is thermally modeled. This ongoing effort is focused on developing accurate balloon thermal models that can be used to quickly predict balloon temperatures and balloon performance. The ability to model parametric changes is also a driver for this effort. This paper will present the most recent advances made in this area. This research effort continues to utilize the "Thrmal Desktop" addition to AUTO CAD for the modeling. Recent advances have been made by using this analytical tool. A number of analyses have been completed to test the applicability of this tool to the problem with very positive results. Progressively detailed models have been developed to explore the capabilities of the tool as well as to provide guidance in model formulation. A number of parametric studies have been completed. These studies have varied the shape of the structure, material properties, environmental inputs, and model geometry. These studies have concentrated on spherical "proxy models" for the initial development stages and then to transition to the natural shaped zero pressure and super pressure balloons. An assessment of required model resolution has also been determined. Model solutions have been cross checked with known solutions via hand calculations. The comparison of these cases will also be presented. One goal is to develop analysis guidelines and an approach for modeling balloons for both simple first order estimates and detailed full models. This papa presents the step by step advances made as part of this effort, capabilities, limitations, and the lessons learned. Also presented are the plans for further thermal modeling work.

  4. Thermal performance modeling of NASA s scientific balloons

    NASA Astrophysics Data System (ADS)

    Franco, H.; Cathey, H.

    The flight performance of a scientific balloon is highly dependant on the interaction between the balloon and its environment. The balloon is a thermal vehicle. Modeling a scientific balloon's thermal performance has proven to be a difficult analytical task. Most previous thermal models have attempted these analyses by using either a bulk thermal model approach, or by simplified representations of the balloon. These approaches to date have provided reasonable, but not very accurate results. Improvements have been made in recent years using thermal analysis tools developed for the thermal modeling of spacecraft and other sophisticated heat transfer problems. These tools, which now allow for accurate modeling of highly transmissive materials, have been applied to the thermal analysis of NASA's scientific balloons. A research effort has been started that utilizes the "Thermal Desktop" addition to AUTO CAD. This paper will discuss the development of thermal models for both conventional and Ultra Long Duration super-pressure balloons. This research effort has focused on incremental analysis stages of development to assess the accuracy of the tool and the required model resolution to produce usable data. The first stage balloon thermal analyses started with simple spherical balloon models with a limited number of nodes, and expanded the number of nodes to determine required model resolution. These models were then modified to include additional details such as load tapes. The second stage analyses looked at natural shaped Zero Pressure balloons. Load tapes were then added to these shapes, again with the goal of determining the required modeling accuracy by varying the number of gores. The third stage, following the same steps as the Zero Pressure balloon efforts, was directed at modeling super-pressure pumpkin shaped balloons. The results were then used to develop analysis guidelines and an approach for modeling balloons for both simple first order estimates and detailed

  5. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    NASA Astrophysics Data System (ADS)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  6. Immediate Outcome of Balloon Mitral Valvuloplasty with JOMIVA Balloon during Pregnancy

    PubMed Central

    Ramasamy, Ramona; Kaliappan, Tamilarasu; Gopalan, Rajendiran; Palanimuthu, Ramasmy; Anandhan, Premkrishna

    2017-01-01

    Introduction Rheumatic mitral stenosis is the most common Valvular Heart Disease encountered during pregnancy. Balloon Mitral Valvuloplasty (BMV) is one of the treatment option available if the symptoms are refractory to the medical management and the valve anatomy is suitable for balloon dilatation. BMV with Inoue balloon is the most common technique being followed worldwide. Over the wire BMV is a modified technique using Joseph Mitral Valvuloplasty (JOMIVA) balloon catheter which is being followed in certain centres. Aim To assess the immediate post procedure outcome of over the wire BMV with JOMIVA balloon. Materials and Methods Clinical and echocardiographic parameters of pregnant women with significant mitral stenosis who underwent elective BMV with JOMIVA balloon in our institute from 2005 to 2015 were analysed retrospectively. Severity of breathlessness (New York Heart Association Functional Class), and duration of pregnancy was included in the analysis. Pre procedural echocardiographic parameters which included severity of mitral stenosis and Wilkin’s scoring were analysed. Clinical, haemodynamic and echocardiographic outcomes immediately after the procedure were analysed. Results Among the patients who underwent BMV in our Institute 38 were pregnant women. Twenty four patients (63%) were in New York Heart Association (NYHA) Class III. All of them were in sinus rhythm except two (5%) who had atrial fibrillation. Thirty four patients (89.5%) were in second trimester of pregnancy at the time of presentation and four (10.5%) were in third trimester. Echocardiographic analysis of the mitral valve showed that the mean Wilkin’s score was 7.3. Mean mitral valve area pre procedure was 0.8 cm2. Mean gradient across the valve was 18 mmHg. Ten patients (26.5%) had mild mitral regurgitation and none had more than mild mitral regurgitation. Thirty six patients had pulmonary hypertension as assessed by tricuspid regurgitation jet velocity. All of them underwent BMV

  7. A Methane Balloon Inflation Chamber

    ERIC Educational Resources Information Center

    Czerwinski, Curtis J.; Cordes, Tanya J.; Franek, Joe

    2005-01-01

    The various equipments, procedure and hazards in constructing the device for inflating a methane balloon using a standard methane outlet in a laboratory are described. This device is fast, safe, inexpensive, and easy to use as compared to a hydrogen gas cylinder for inflating balloons.

  8. Balloon pulmonary valvotomy--not just a simple balloon dilatation.

    PubMed

    Mohanty, Subhendu; Pandit, Bhagya Narayan; Tyagi, Sanjay

    2014-01-01

    Balloon pulmonary valvotomy is the preferred mode of treatment in patients with isolated pulmonary valvar stenosis and has shown good long term results. It is generally considered a safe procedure with few complications. There have been however, case reports of potentially fatal acute severe pulmonary edema occurring after the procedure in some patients. The cause of this complication and its pathophysiology is still not clear. Its occurrence is also infrequent with less than 5 cases reported till now. We report a case of pulmonary valvar stenosis which developed acute severe refractory pulmonary edema immediately after balloon pulmonary valvotomy. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  9. 14 CFR 61.115 - Balloon rating: Limitations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... takes a practical test in a balloon with an airborne heater: (1) The pilot certificate will contain a limitation restricting the exercise of the privileges of that certificate to a balloon with an airborne... removed when the person obtains the required aeronautical experience in a balloon with an airborne heater...

  10. Gradient magnetometer system balloons

    NASA Astrophysics Data System (ADS)

    Korepanov, Valery; Tsvetkov, Yury

    2005-08-01

    Earth's magnetic field study still remains one of the leading edges of experimental geophysics. Thus study is executed on the Earth surface, including ocean bottom, and on satellite heights using component, mostly flux-gate magnetometers. But balloon experiments with component magnetometers are very seldom, first of all because of great complexity of data interpretation. This niche still waits for new experimental ideology, which will allow to get the measurements results with high accuracy, especially in gradient mode. The great importance of precise balloon-borne component magnetic field gradient study is obvious. Its technical realization is based both on the available at the marked high-precision non-magnetic tiltmeters and on recent achievements of flux-gate magnetometry. The scientific goals of balloon-borne magnetic gradiometric experiment are discussed and its practical realization is proposed.

  11. Laser welding of balloon catheters

    NASA Astrophysics Data System (ADS)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  12. NASA Langley Research Center tethered balloon systems

    NASA Technical Reports Server (NTRS)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  13. Heat Transfer Model for Hot Air Balloons

    NASA Astrophysics Data System (ADS)

    Llado-Gambin, Adriana

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.

  14. Balloon Borne Ultraviolet Spectrometer.

    DTIC Science & Technology

    1978-12-28

    n.c.aaary ond lden lfy by block numb.r) ultraviolet ground support equipment (GSE) spectrometers flight electronics instrumentation balloons \\ solar ...Assembly 4 Fig. 3 Solar Balloon Experiment Ass ’y 7 Fig. 4 Mechanical Interface , UV Spectrometer 8 Fig . 5 Spectrometer Body Assemb ly 10 Fig. 6...Diagram, GSE )bnitor 48 Selector and Battery Charger Fig. 25 Schematic Diagram, GSE Serial to 49 Parallel Data Converter Fig. 26 Schematic Diagram

  15. Determination of balloon drag

    NASA Technical Reports Server (NTRS)

    Conrad, George R.; Robbins, Edward J.

    1991-01-01

    The evolution of an empirical drag relationship that has stimulated rethinking regarding the physics of balloon drag phenomena is discussed. Combined parasitic drag from all sources in the balloon system are estimated to constitute less than 10 percent of the total system drag. It is shown that the difference between flight-determined drag coefficients and those based on the spherical assumption should be related to the square of the Froude number.

  16. Yellow Balloon in a Briar Patch.

    ERIC Educational Resources Information Center

    Cooper, Frank; Fitzmaurice, Robert W.

    1978-01-01

    As part of a meteorology unit, sixth grade science students launched helium balloons with attached return postcards. This article describes Weather Service monitoring of the balloons and postcard return results. (MA)

  17. 21 CFR 874.4100 - Epistaxis balloon.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...

  18. Auditory Risk of Exploding Hydrogen-Oxygen Balloons

    ERIC Educational Resources Information Center

    Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.

    2010-01-01

    Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…

  19. Balloon cell nevus of the iris.

    PubMed

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  20. The French Balloon Program 2013 - 2017

    NASA Astrophysics Data System (ADS)

    Dubourg, Vincent; Vargas, André; Raizonville, Philippe

    2016-07-01

    With over 50 years' experience in the field, the French Centre National d'Etudes Spatiales (CNES) goes on supporting - as designer and operator - a significant scientific ballooning program. In particular so because balloons still give a unique and valuable access to near space science. From 2008 to 2013, an important renovation effort was achieved, beginning by Zero Pressure Balloons (ZPB) systems, to comply with more stringent Safety constraints and to the growing reliability and performance requirements from scientific missions. The paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2015 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for ZPB, qualified in flight in 2013. In particular, the PILOT telescope successfully flew during the 2015 campaign, key figures about the flight and mission will be given. An outlook of the new stratospheric long duration flight systems currently in process of developement at CNES will be given, as well as the presentation of the Stratéole 2 project, dedicated to the survey of the low stratosphere and upper troposphere in equatorial regions, with a fleet of small suprer pressure balloons (SPB). As far as tropospheric balloons are concerned, the Aeroclipper initiative will be presented, aiming at qualifying a quasi-tethered balloon, pushed by the winds close to the sea surface, for the study of cyclones. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.

  1. Effects of single doses of rabeprazole 20 mg and esomeprazole 40 mg on 24-h intragastric pH in healthy subjects.

    PubMed

    Warrington, Steve; Baisley, Kathy; Dunn, Kate; Boyce, Malcolm; Morocutti, Anna

    2006-09-01

    To compare antisecretory effects of single doses of rabeprazole and esomeprazole. Open, randomised, 2-way crossover, clinical pharmacology study. 24 healthy subjects (10 men; mean age 26.2 y) received a single dose of rabeprazole 20 mg or esomeprazole 40 mg, with a 14-day 'washout'. Intragastric pH was recorded continuously from 24 h before to 24 h after dosing. Mean intragastric pH was higher after esomeprazole than rabeprazole during 0-5 h after dosing (P=0.0001); the reverse was true from 14-24 h (P=0.0002). Mean % time pH>3 and >4 was greater after esomeprazole than rabeprazole during 0-14 h (P=0.041 and 0.044), but the reverse was true during 14-24 h (P=0.0005 and 0.001). In the 0-24 h interval as a whole, there was no difference between treatments in mean pH or % time pH>3 or >4. Single-dose rabeprazole 20 mg was as effective as esomeprazole 40 mg in increasing intragastric pH and maintaining pH>3 and >4, despite the 2-fold difference in dose.

  2. Vertical sounding balloons for stratospheric photochemistry

    NASA Astrophysics Data System (ADS)

    Pommereau, J. P.

    The use of vertical sounding balloons for stratospheric photochemistry studies is illustrated by the use of a vertical piloted gas balloon for the search of NO2 diurnal variations. It is shown that the use of montgolfieres (hot air balloons) can enhance the vertical sounding technique. Particular attention is given to a sun-heated montgolfiere and to the more sophisticated infrared montgolfiere that is able to perform three to four vertical excursions per day and to remain aloft for weeks or months.

  3. Balloon mania: news in the air.

    PubMed

    Kim, Mi Gyung

    2004-12-01

    The hot-air balloon, invented by the Montgolfier brothers in 1783, enabled the French King to project his glory, the nobility to exhibit their valor, the literary public to transmit the ideal of the Enlightenment and the plebian public to rejoice in a scientific spectacle. The ensuing balloon mania helped create an integrated public that, because of its size and composition, can only be described as 'democratic' just a few years before the French Revolution. The monumental impact of the balloon was well represented in a flood of poetry, pamphlets, books, journal reports, academic papers and consumer items. Sifting through these artifacts and considering the crowd that witnessed the ascent of the balloon will bring us to the historical moment when things, spectacles, and events (rather than words) shaped public and popular opinion.

  4. Effect of charge density of polysaccharides on self-assembled intragastric gelation of whey protein/polysaccharide under simulated gastric conditions.

    PubMed

    Zhang, Sha; Zhang, Zhong; Vardhanabhuti, Bongkosh

    2014-08-01

    This study focuses on the behavior of mixed protein and polysaccharides with different charge densities under simulated gastric conditions. Three types of polysaccharides, namely, guar gum, xanthan gum and carrageenan (neutral, medium negatively, and highly negatively charged, respectively) were selected for heating together with whey protein isolate (WPI) at a biopolymer ratio ranging from 0.01 to 0.1. Upon mixing with simulated gastric fluid (SGF), all WPI-guar gum samples remained soluble, whereas WPI-xanthan gum and WPI-carrageenan at biopolymer ratio higher than 0.01 led to self-assembled intragastric gelation immediately after mixing with SGF. The mechanism behind the intragastric gelation is believed to be the cross-linking between oppositely charged protein and polysaccharides when pH was reduced to below the pI of the protein. Higher biopolymer ratio led to a higher degree of intermolecular interaction, which tends to form stronger gel. More negatively charged carrageenan also formed a stronger gel than xanthan gum. SDS-PAGE results show that the digestibility of protein was not affected by the presence of guar gum as well as xanthan gum and carrageenan at biopolymer ratio lower than 0.02. However, intragastric gel formed by WPI-xanthan gum and WPI-carrageenan at biopolymer ratio higher than 0.02 significantly slows down the digestion rate of protein, which could potentially be used to delay gastric emptying and promote satiety.

  5. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    PubMed

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  6. Use of monorail PTCA balloon catheter for local drug delivery.

    PubMed

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  7. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    PubMed

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p < 0.01), and the proportion of restenosis occurrence that required further treatment was decreased at 6 months (46.9 vs. 81.8%), especially for the web-like stenosis patients, as most of their stenoses dilated with no obvious restenosis and achieved clinical cure. Electrocautery needle knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  8. Global electrodynamics from superpressure balloons

    NASA Technical Reports Server (NTRS)

    Holzworth, R. H.; Hu, H.

    1995-01-01

    Electric field and conductivity measurements in the stratosphere between November 1992 and March 1993 have been made using superpressure balloons in the southern hemisphere. Over 400 payload-days of data have been made during a record setting experiment called ELBBO (Extended Life Balloon Borne Observatories). This experiment resulted in 4 flights aloft simultaneously for over 2 months including one flight which lasted over 4 months. Electrodynamical coupling between the atmosphere and ionosphere is studied using the measured electric fields, and a simple empirical model of the stratospheric conductivity. Altitude profiles of conductivity have been obtained from several superpressure balloon flights using the large end-of-flight altitude swings on the last few days of each flight (as the balloon begins to loose superpressure). Coupling between the fields and atmospheric inertial waves has been observed. Effects and dynamics of the global circuit suggest that standard models are missing significant phenomena. Large scale ionospheric convection activity has been studied from the polar cap to the middle latitudes. Cusp latitude fields have been continuously measured for many days in a row.

  9. NASA Scientific Balloon in Antarctica

    NASA Image and Video Library

    2017-12-08

    NASA image captured December 25, 2011 A NASA scientific balloon awaits launch in McMurdo, Antarctica. The balloon, carrying Indiana University's Cosmic Ray Electron Synchrotron Telescope (CREST), was launched on December 25. After a circum-navigational flight around the South Pole, the payload landed on January 5. The CREST payload is one of two scheduled as part of this seasons' annual NASA Antarctic balloon Campaign which is conducted in cooperation with the National Science Foundation's Office of Polar Programs. The campaign's second payload is the University of Arizona's Stratospheric Terahertz Observatory (STO). You can follow the flights at the Columbia Scientific Balloon Facility's web site at www.csbf.nasa.gov/antarctica/ice.htm Credit: NASA NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  10. Development of a Super-Pressure Balloon with an Improved Design

    NASA Astrophysics Data System (ADS)

    Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya

    A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.

  11. Evolution of scientific ballooning and its impact on astrophysics research

    NASA Astrophysics Data System (ADS)

    Jones, William Vernon

    2014-05-01

    As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.

  12. Absorption spectrometer balloon flight and iodine investigations

    NASA Technical Reports Server (NTRS)

    1970-01-01

    A high altitude balloon flight experiment to determine the technical feasibility of employing absorption spectroscopy to measure SO2 and NO2 gases in the earth's atmosphere from above the atmospheric ozone layer is discussed. In addition to the balloon experiment the contract includes a ground-based survey of natural I emissions from geological sources and studies of the feasibility of mapping I2 from spacecraft. This report is divided into three major sections as follows: (1) the planning engineering and execution of the balloon experiment, (2) data reduction and analysis of the balloon data, and (3) the results of the I2 phase of the contract.

  13. Aerodynamics of a Party Balloon

    ERIC Educational Resources Information Center

    Cross, Rod

    2007-01-01

    It is well-known that a party balloon can be made to fly erratically across a room, but it can also be used for quantitative measurements of other aspects of aerodynamics. Since a balloon is light and has a large surface area, even relatively weak aerodynamic forces can be readily demonstrated or measured in the classroom. Accurate measurements…

  14. [Changes in gastric function in rats after intragastric introduction of corvitin at high doses].

    PubMed

    Vovkun, T V; Ianchuk, P I; Shtanova, L Ia; Vesel'skyĭ, S P; Baranovs'kyĭ, V A

    2014-01-01

    Intragastric administration of corvitin at doses of 10, 20 and 40 mg/kg dose-dependently increased the volume of gastric juice and the total production of hydrochloric acid (HA). Amplification of hexosamines and cysteine production was observed only when the study drug was administered at a dose of 10 mg/kg. When corvitin was used at 20 and 40 mg/kg, these parameters were at the level of control values. Protein production increased in response to 10 and 20 mg/kg corvitin, but fell below the control values after administration of 40 mg/kg of the drug. The level of blood flow in the gastric mucosa increased following administration of 10 mg/kg corvitin, was not different from the baseline after 20 mg/kg of the drug and significantly decreased in response to 40 mg/kg of flavonoid. Our results indicate that a single intragastric application of corvitin at dose of 10 mg/kg activates gastric defense mechanisms. At 20 and 40 mg/kg, corvitin does not affect them but gradually reduces blood flow in gastric mucosa, causes a disturbance of protein synthesis and hypersecretion of HA into the cavity of the stomach, which can lead to disruption of the digestive process and the integrity of gastric mucosa.

  15. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    PubMed

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Concepts for autonomous flight control for a balloon on Mars

    NASA Technical Reports Server (NTRS)

    Heinsheimer, Thomas F.; Friend, Robyn C.; Siegel, Neil G.

    1988-01-01

    Balloons operating as airborne rovers have been suggested as ideal candidates for early exploration of the Martian surface. An international study team composed of scientists from the U.S.S.R., France, and the U.S.A. is planning the launching in 1994 of a balloon system to fly on Mars. The current likely design is a dual thermal/gas balloon that consists of a gas balloon suspended above a solar-heated thermal balloon. At night, the thermal balloon provides no lift, and the balloon system drifts just above the Martian surface; the lift of the gas balloon is just sufficient to prevent the science payload from hitting the ground. During the day, the balloon system flies at an altitude of 4 to 5 kilometers, rising due to the added lift provided by the thermal balloon. Over the course of a single Martian day, there may be winds in several directions, and in fact it can be expected that there will be winds simultaneously in different directions at different altitudes. Therefore, a balloon system capable of controlling its own altitude, via an autonomous flight control system, can take advantage of these different winds to control its direction, thereby greatly increasing both its mission utility and its longevity.

  17. Stratospheric Balloons for Planetary Science and the Balloon Observation Platform for Planetary Science (BOPPS) Mission Summary

    NASA Technical Reports Server (NTRS)

    Kremic, Tibor; Cheng, Andrew F.; Hibbitts, Karl; Young, Eliot F.; Ansari, Rafat R.; Dolloff, Matthew D.; Landis, Rob R.

    2015-01-01

    NASA and the planetary science community have been exploring the potential contributions approximately 200 questions raised in the Decadal Survey have identified about 45 topics that are potentially suitable for addressing by stratospheric balloon platforms. A stratospheric balloon mission was flown in the fall of 2014 called BOPPS, Balloon Observation Platform for Planetary Science. This mission observed a number of planetary targets including two Oort cloud comets. The optical system and instrumentation payload was able to provide unique measurements of the intended targets and increase our understanding of these primitive bodies and their implications for us here on Earth. This paper will discuss the mission, instrumentation and initial results and how these may contribute to the broader planetary science objectives of NASA and the scientific community. This paper will also identify how the instrument platform on BOPPS may be able to contribute to future balloon-based science. Finally the paper will address potential future enhancements and the expected science impacts should those enhancements be implemented.

  18. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    PubMed

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Fat Emulsion Intragastric Stability and Droplet Size Modulate Gastrointestinal Responses and Subsequent Food Intake in Young Adults1234

    PubMed Central

    Hussein, Mahamoud O; Hoad, Caroline L; Wright, Jeff; Singh, Gulzar; Stephenson, Mary C; Cox, Eleanor F; Placidi, Elisa; Pritchard, Susan E; Costigan, Carolyn; Ribeiro, Henelyta; Ciampi, Elisabetta; Nandi, Asish; Hedges, Nick; Sanderson, Paul; Peters, Harry PF; Rayment, Pip; Spiller, Robin C; Gowland, Penny A

    2015-01-01

    Background: Intragastric creaming and droplet size of fat emulsions may affect intragastric behavior and gastrointestinal and satiety responses. Objectives: We tested the hypotheses that gastrointestinal physiologic responses and satiety will be increased by an increase in intragastric stability and by a decrease in fat droplet size of a fat emulsion. Methods: This was a double-blind, randomized crossover study in 11 healthy persons [8 men and 3 women, aged 24 ± 1 y; body mass index (in kg/m2): 24.4 ± 0.9] who consumed meals containing 300-g 20% oil and water emulsion (2220 kJ) with 1) larger, 6-μm mean droplet size (Coarse treatment) expected to cream in the stomach; 2) larger, 6-μm mean droplet size with 0.5% locust bean gum (LBG; Coarse+LBG treatment) to prevent creaming; or 3) smaller, 0.4-μm mean droplet size with LBG (Fine+LBG treatment). The participants were imaged hourly by using MRI and food intake was assessed by using a meal that participants consumed ad libitum. Results: The Coarse+LBG treatment (preventing creaming in the stomach) slowed gastric emptying, resulting in 12% higher gastric volume over time (P < 0.001), increased small bowel water content (SBWC) by 11% (P < 0.01), slowed appearance of the 13C label in the breath by 17% (P < 0.01), and reduced food intake by 9% (P < 0.05) compared with the Coarse treatment. The Fine+LBG treatment (smaller droplet size) slowed gastric emptying, resulting in 18% higher gastric volume (P < 0.001), increased SBWC content by 15% (P < 0.01), and significantly reduced food intake by 11% (P < 0.05, equivalent to an average of 411 kJ less energy consumed) compared with the Coarse+LBG treatment. These high-fat meals stimulated substantial increases in SBWC, which increased to a peak at 4 h at 568 mL (range: 150–854 mL; P < 0.01) for the Fine+LBG treatment. Conclusion: Manipulating intragastric stability and fat emulsion droplet size can influence human gastrointestinal physiology and food intake. PMID

  20. Fracture, inflation and floatation embolisation of PTCA balloon.

    PubMed

    O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick

    2015-01-09

    This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in 'inflation' of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing 'floatation' embolisation into the coronary artery. 2015 BMJ Publishing Group Ltd.

  1. Fracture, inflation and floatation embolisation of PTCA balloon

    PubMed Central

    O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick

    2015-01-01

    This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in ‘inflation’ of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing ‘floatation’ embolisation into the coronary artery. PMID:25576524

  2. Effect of intragastric acid stability of fat emulsions on gastric emptying, plasma lipid profile and postprandial satiety.

    PubMed

    Marciani, Luca; Faulks, Richard; Wickham, Martin S J; Bush, Debbie; Pick, Barbara; Wright, Jeff; Cox, Eleanor F; Fillery-Travis, Annette; Gowland, Penny A; Spiller, Robin C

    2009-03-01

    Fat is often included in common foods as an emulsion of dispersed oil droplets to enhance the organoleptic quality and stability. The intragastric acid stability of emulsified fat may impact on gastric emptying, satiety and plasma lipid absorption. The aim of the present study was to investigate whether, compared with an acid-unstable emulsion, an acid-stable fat emulsion would empty from the stomach more slowly, cause more rapid plasma lipid absorption and cause greater satiety. Eleven healthy male volunteers received on two separate occasions 500 ml of 15 % (w/w) [13C]palmitate-enriched olive oil-in-water emulsion meals which were either stable or unstable in the acid gastric environment. MRI was used to measure gastric emptying and the intragastric oil fraction of the meals. Blood sampling was used to measure plasma lipids and visual analogue scales were used to assess satiety. The acid-unstable fat emulsion broke and rapidly layered in the stomach. Gastric emptying of meal volume was slower for the acid-stable fat emulsion (P < 0.0001; two-way ANOVA). The rate of energy delivery of fat from the stomach to the duodenum was not different up to t = 110 min. The acid-stable emulsion induced increased fullness (P < 0.05), decreased hunger (P < 0.0002), decreased appetite (P < 0.0001) and increased the concentration of palmitic acid tracer in the chylomicron fraction (P < 0.04). This shows that it is possible to delay gastric emptying and increase satiety by stabilising the intragastric distribution of fat emulsions against the gastric acid environment. This could have implications for the design of novel foods.

  3. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    A BARREL balloon floats into the sky as it is partially filled. When fully inflated, each balloon is 90 feet in diameter and carries an instrument suite that weighs 50 pounds. This is small for an Antarctica balloon launch, which can have balloons Typical balloons l the size of a football field with payloads of some 3,000 pounds. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in

  4. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  5. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  6. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  7. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  8. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  9. Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons

    ERIC Educational Resources Information Center

    Jadrich, James; Bruxvoort, Crystal

    2010-01-01

    Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…

  10. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.

    2011-07-15

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less

  11. Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons

    PubMed Central

    Antony, Kathleen M.; Racusin, Diana A.; Belfort, Michael A.; Dildy, Gary A.

    2017-01-01

    Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling. PMID:28497006

  12. Overview of the Scientific Balloon Activity in Sweden

    NASA Astrophysics Data System (ADS)

    Abrahamsson, Mattias; Kemi, Stig; Lockowandt, Christian; Andersson, Kent

    SSC, formerly known as Swedish Space Corporation, is a Swedish state-owned company working in several different space related fields, including scientific stratospheric balloon launches. Esrange Space Centre (Esrange in short) located in the north of Sweden is the launch facility of SSC, where both sounding rocket launches and stratospheric balloon launches are conducted. At Esrange there are also facilities for satellite communication, including one of the largest civilian satellite data reception stations in the world. Stratospheric balloons have been launched from Esrange since 1974, when the first flights were performed together with the French space agency CNES. These balloon flights have normally flown eastward either only over Sweden or into Finland. Some flights have also had permission to fly into Russia, as far as the Ural Mountains. Normal flight times are from 4 to 12 hours. These eastward flights are conducted during the winter months (September to May). Long duration flights have been flown from ESC since 2005, when NASA flew the BLAST payload from Sweden to north Canada. The prevailing westerly wind pattern is very advantageous for trans-Atlantic flights during summer (late May to late July). The long flight times are very beneficial for astronomical payloads, such as telescopes that need long observation times. In 2013 two such payloads were flown, the first called SUNRISE was a German/US solar telescope, and the other called PoGOLite with a Swedish gamma-ray telescope. In 14 days PoGOLite, which had permission to fly over Russia, made an almost complete circumpolar flight. Typical scientific balloon payload fields include atmospheric research, including research on ozone depletion, astronomical and cosmological research, and research in technical fields such as aerodynamics. University students from all over Europe are involved in flights from Esrange under a Swedish/German programme called BEXUS. Two stratospheric balloons are flown with student

  13. Induction of Fos expression in the rat forebrain after intragastric administration of monosodium L-glutamate, glucose and NaCl.

    PubMed

    Otsubo, H; Kondoh, T; Shibata, M; Torii, K; Ueta, Y

    2011-11-24

    l-glutamate, an umami taste substance, is a key molecule coupled to a food intake signaling pathway. Furthermore, recent studies have unveiled new roles for dietary glutamate on gut-brain axis communication via activation of gut glutamate receptors and subsequent vagus nerve. In the present study, we mapped activation sites of the rat forebrain after intragastric load of 60 mM monosodium l-glutamate (MSG) by measurement of Fos protein, a functional marker of neuronal activation. The same concentration of d-glucose (sweet) and NaCl (salty) was used as controls. MSG administration exclusively produced enhanced Fos expression in four hypothalamic regions (the medial preoptic area, lateral hypothalamic area, dorsomedial nucleus, and arcuate nucleus). On the other hand, glucose administration exclusively enhanced Fos induction in the nucleus accumbens. Both MSG and glucose enhanced Fos induction in three brain regions (the habenular nucleus, paraventricular nucleus, and central nucleus of the amygdala). However, MSG induced Fos inductions were more potent than those of glucose in the habenular nucleus and paraventricular nucleus. Importantly, the present study identified for the first time two brain areas (the paraventricular and arcuate hypothalamic nuclei) that are more potently activated by intragastric MSG loads compared with glucose and NaCl. Overall, our results suggest significant activation of a neural network comprising the habenular nucleus, amygdala, and the hypothalamic subnuclei following intragastric load with glutamate. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

  14. Simulating clefts in pumpkin balloons

    NASA Astrophysics Data System (ADS)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  15. Retained intraaortic balloon. Case report and review of the literature.

    PubMed

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  16. Incorporation of Scientific Ballooning into Science Education

    NASA Astrophysics Data System (ADS)

    Chanover, N.; Stochaj, S.; Petty, C.

    1999-12-01

    We are augmenting the science curriculum of the Roswell Independent School District in Roswell, NM, to take advantage of the proximity of a NASA scientific balloon base. The basic science related to balloon experimentation is being incorporated into the K-12 science curriculum via the discussion of topics such as atmospheric properties, weather, phases of matter, plotting skills, and communications in the context of a high-altitude balloon flight. These efforts will culminate in the construction of balloon-borne instruments by high school students, which will be launched during the spring of 2000. A demonstration flight, launched in the spring of 1999, was used to build student enthusiasm and community support for this program, which is funded by the NASA/IDEAS program.

  17. Nimbus 4/IRLS Balloon Interrogation Package (BIP)

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The balloon interrogation package (BIP), an integral part of the overall interrogation, recording, and location subsystems (IRLS) for the Nimbus 4 program, is described. The BIP is a self-contained, integrated transponder designed to be carried aloft by a constant altitude, superpressure balloon to an altitude of 67,000 or 78,000 feet. After launch the BIP senses high-altitude balloon overpressure and temperature, and upon receipt of an interrogated command from the IRLS aboard the Nimbus 4 satellite, the BIP enodes the data on a real-time basis into a pulse-code modulation (PCM) format and transmits this data to the satellite. A summary of the program activity to produce 30 BIP systems and to support balloon launches from Ascension Island is presented.

  18. Scientific balloons: historical remarks.

    NASA Astrophysics Data System (ADS)

    Ubertini, P.

    The paper is an overview of the Human attempt to fly, from the myth of Daedalus and his son Icarus to the first "aerostatic" experiment by Joseph-Michel and Jaques-Etienne Montgolfier. Then, via a jump of about 200 years, we arrive to the era of the modern stratospheric ballooning that, from the beginning of the last century, have provided a unique flight opportunity for aerospace experiments. In particular, the Italian scientific community has employed stratospheric balloons since the '50s for cosmic rays and high energy astrophysical experiments with initial launches performed from Cagliari Helmas Airport (Sardinia). More recently an almost ideal location was found in the area of Trapani-Milo (Sicily, Italy), were an old abandoned airport was refurbished to be used as a new launch site that became operative at the beginning of the '70s. Finally, we suggest a short reminiscence of the first transatlantic experiment carried out on August 1975 in collaboration between SAS-CNR (Italy) and NSBF-NASA (USA). The reason why the Long Duration Balloon has been recently re-oriented in a different direction is analysed and future perspectives discussed. Finally, the spirit of the balloon launch performed by the Groups lead by Edoardo Amaldi, Livio Scarsi and other Italian pioneers, with payloads looking like "refrigerators" weighting a few tens of kg is intact and the wide participation to the present Workshop is the clear demonstration.

  19. Balloon augmented Onyx embolization utilizing a dual lumen balloon catheter: utility in the treatment of a variety of head and neck lesions.

    PubMed

    Spiotta, Alejandro M; Miranpuri, Amrendra S; Vargas, Jan; Magarick, Jordan; Turner, Raymond D; Turk, Aquilla S; Chaudry, M Imran

    2014-09-01

    Endovascular embolization for tumors and vascular malformations has emerged as an important preoperative adjunct prior to resection. We describe the advantages of utilizing a recently released dual lumen balloon catheter for ethylene vinyl alcohol copolymer, also known as Onyx (ev3, Irvine, California, USA), embolization for a variety of head and neck pathologies. A retrospective review of all cases utilizing the Scepter C balloon catheter (MicroVention Inc, Tustin, California, USA) for use in balloon augmented embolization was performed over a 4 month period from October 2012 to February 2013 at the Medical University of South Carolina, Charleston, South Carolina, USA. Charts and angiographic images were reviewed. Representative cases involving diverse pathologies are summarized and illustrate the observed advantages of balloon augmented Onyx embolization with a dual lumen balloon catheter. Balloon augmented Onyx embolization utilizing a novel dual lumen balloon catheter was employed to treat both ruptured and unruptured arteriovenous malformations, intracranial dural arteriovenous fistulae, intracranial neoplasms, carotid body tumors, a thyroid mass, and an extracranial arteriovenous fistula. The dual lumen balloon catheter has several advantages for use with Onyx embolization over older devices, including more efficient proximal plug formation and enhanced navigability for placement deep within the pedicles. The balloon augmented Onyx embolization technique represents a valuable tool to add to the armamentarium of the neurointerventionalist to address a variety of head and neck lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Balloon Exoplanet Nulling Interferometer (BENI)

    NASA Technical Reports Server (NTRS)

    Lyon, Richard G.; Clampin, Mark; Woodruff, Robert A.; Vasudevan, Gopal; Ford, Holland; Petro, Larry; Herman, Jay; Rinehart, Stephen; Carpenter, Kenneth; Marzouk, Joe

    2009-01-01

    We evaluate the feasibility of using a balloon-borne nulling interferometer to detect and characterize exosolar planets and debris disks. The existing instrument consists of a 3-telescope Fizeau imaging interferometer with 3 fast steering mirrors and 3 delay lines operating at 800 Hz for closed-loop control of wavefront errors and fine pointing. A compact visible nulling interferometer is under development which when coupled to the imaging interferometer would in-principle allow deep suppression of starlight. We have conducted atmospheric simulations of the environment above 100,000 feet and believe balloons are a feasible path forward towards detection and characterization of a limited set of exoplanets and their debris disks. Herein we will discuss the BENI instrument, the balloon environment and the feasibility of such as mission.

  1. Retained intraaortic balloon. Case report and review of the literature.

    PubMed Central

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home. Images PMID:8605436

  2. [A case of intragastric wall abscess formation during bevacizumab combined chemotherapy].

    PubMed

    Mori, Ayano; Kogawa, Takahiro; Arihara, Youhei; Abe, Masakazu; Tamura, Fumito; Abe, Seiichirou; Kukitsu, Takehiro; Ihara, Hideyuki; Sumiyoshi, Tetsuya; Yoshizaki, Naoto; Kondou, Hitoshi; Tsuji, Yasushi

    2013-05-01

    A 38-year-old man was given a diagnosis of as sigmoid colon cancer and underwent sigmoid colectomy. Post-operative pathological staging was stage IIIb. He then underwent adjuvant chemotherapy. One year and 4 months after the surgery, CT scans revealed multiple liver and lung metastases. He was given mFOLFOX6+bevacizumab, which was changed later to FOLFIRI+bevacizumab. After these chemotherapies, he was admitted to the hospital due to sudden abdominal pain and high grade fever. Obstructive jaundice was initially diagnosed, but detailed study of initial CT revealed intragastric wall abscess. After the drainage of the abscess, his conditions improved. We speculated that the abscess formation was caused by mucosal damage due to bevacizumab.

  3. Low-Altitude Exploration of the Venus Atmosphere by Balloon

    NASA Technical Reports Server (NTRS)

    Landis, Geoffrey A.

    2010-01-01

    The planet Venus represents an exciting target for future exploration by spacecraft. One target of scientific interest is the lower atmosphere, which represents an environment of high temperature and moderate to high atmospheric pressure. This represents a considerable challenge to the technical art of ballooning, but one which may be amenable to solution. Several possible designs for low-altitude balloons are discussed. Conceptual design for three mission examples are analyzed: a conventional balloon operating below the cloud level at an altitude of 25 kilometers, a large rigid-envelope balloon operating near the surface at an altitude of 5 kilometers, and a small, technology demonstrator rigid-envelope balloon operating at 5 kilometers.

  4. The radiation controlled balloon (RACOON)

    NASA Astrophysics Data System (ADS)

    Lally, Vincent E.

    The RACOON concept permits the flight of large, low-cost polyethylene balloons for several weeks at stratospheric altitudes without ballast. The theory of operations is described. The RACOON balloon ascends each morning and descends at night. This movement of 15 to 20 km in altitude provides an ideal platform for vertical soundings and sampling measurements in the stratosphere. Results of a number of globe-circling flights are presented.

  5. Investigations of immunogenic, allergenic and adjuvant properties of Cry1Ab protein after intragastric exposure in a food allergy model in mice.

    PubMed

    Andreassen, Monica; Bøhn, Thomas; Wikmark, Odd-Gunnar; Bodin, Johanna; Traavik, Terje; Løvik, Martinus; Nygaard, Unni Cecilie

    2016-05-04

    In genetically modified (GM) crops there is a risk that the inserted genes may introduce new allergens and/or adjuvants into the food and feed chain. The MON810 maize, expressing the insecticidal Cry1Ab toxin, is grown in many countries worldwide. In animal models, intranasal and intraperitoneal immunisations with the purified Cry1Ab proteins have induced immune responses, and feeding trials with Cry1Ab-containing feed have revealed some altered immune responses. Previous investigations have primarily measured antibody responses to the protein, while investigations of clinical food allergy symptoms, or allergy promotion (adjuvant effect) associated with the Cry1Ab protein are largely missing. We aimed to investigate immunogenic, allergenic and adjuvant properties of purified Cry1Ab toxin (trypCry1Ab, i.e., trypsin activated Cry1Ab) in a mouse model of food allergy. Female C3H/HeJ mice were immunized by intragastric gavage of 10 μg purified, trypsin activated Cry1Ab toxin (trypCry1Ab) alone or together with the food allergen lupin. Cholera toxin was added as a positive control for adjuvant effect to break oral tolerance. Clinical symptoms (anaphylaxis) as well as humoral and cellular responses were assessed. In contrast to results from previous airway investigations, we observed no indication of immunogenic properties of trypCry1Ab protein after repeated intragastric exposures to one dose, with or without CT as adjuvant. Moreover, the results indicated that trypCry1Ab given by the intragastric route was not able to promote allergic responses or anaphylactic reactions against the co-administered allergen lupin at the given dose. The study suggests no immunogenic, allergenic or adjuvant capacity of the given dose of trypCry1Ab protein after intragastric exposure of prime aged mice.

  6. The NASA super pressure balloon - A path to flight

    NASA Astrophysics Data System (ADS)

    Cathey, H. M.

    2009-07-01

    The National Aeronautics and Space Administration's Balloon Program Office has invested significant time and effort in extensive ground testing of model super pressure balloons. The testing path has been developed as an outgrowth of the results of the super pressure balloon test flight in 2006. Summary results of the June 2006 super pressure test flight from Kiruna, Sweden are presented including the balloon performance and "lessons learned". This balloons flight performance exceeded expectations, but did not fully deploy. The flight was safely terminated by command. The results of this test flight refocused the project's efforts toward additional ground testing and analysis; a path to flight. A series of small 4 m diameter models were made and tested to further explore the deployment and structural capabilities of the balloons and materials. A series of ˜27 m model balloons were successfully tested indoors. These balloons successfully replicated the cleft seen in the Sweden flight, explored the deployment trade space to help characterize better design approaches, and demonstrated an acceptable fix to the deployment issue. Photogrammetry was employed during these ˜27 m model tests to help characterize both the balloon and gore shape evolution under pressurization. A ˜8.5 m ground model was used to explore the design and materials performance. Results of these tests will be presented. A general overview of some of the other project advancements made related to demonstrating the strain arresting nature of the proposed design, materials and analysis work will also be presented. All of this work has prepared a clear path toward a renewed round of test flights. This paper will give an overview of the development approach pursued for this super pressure balloon development. A description of the balloon design, including the modifications made as a result of the lessons learned, is presented. A short deployment test flight of the National Aeronautics and Space

  7. Experiments with Helium-Filled Balloons

    NASA Astrophysics Data System (ADS)

    Zable, Anthony C.

    2010-12-01

    The concepts of Newtonian mechanics, fluids, and ideal gas law physics are often treated as separate and isolated topics in the typical introductory college-level physics course, especially in the laboratory setting. To bridge these subjects, a simple experiment was developed that utilizes computer-based data acquisition sensors and a digital gram scale to estimate the molar mass of the gas in an inflated balloon. In this experiment, the comparable density of an inflated balloon to that of atmospheric air introduces a significant role for buoyancy that must be accounted for. The ideal gas law approximation is assumed for both the isolated gas mixture within the balloon and the surrounding air, which defines the relationship between the gas pressure, volume, temperature, and molar quantity. Analysis of the forces associated with the inflated balloon with the incorporation of Archimedes' principle and the ideal gas law into Newton's second law results in an experimental method for the measurement of the molar mass and mole fraction of a gas that is easy to implement yet academically challenging for students. The following narrative describes the basic setup of this experiment, along with a sample set of data as acquired and analyzed by a typical physics student from one of my classes.

  8. Balloon concepts for scientific investigation of Mars and Jupiter

    NASA Technical Reports Server (NTRS)

    Ash, R. L.

    1979-01-01

    Opportunities for scientific investigation of the atmospheric planets using buoyant balloons have been explored. Mars and Jupiter were considered in this study because design requirements at those planets bracket nominally the requirements at Venus, and plans are already underway for a joint Russian-French balloon system at Venus. Viking data has provided quantitative information for definition of specific balloon systems at Mars. Free flying balloons appear capable of providing valuable scientific support for more sophisticated Martian surface probes, but tethered and powered aerostats are not attractive. The Jovian environment is so extreme, hot atmosphere balloons may be the only scientific platforms capable of extended operations there. However, the estimated system mass and thermal energy required are very large.

  9. Analysis of Flight of Near-Space Balloon

    NASA Astrophysics Data System (ADS)

    Miller, Zech; Evans, Austin; Seyfert, James; Leadlove, Kyle; Gumina, Kaitlyn; Martell, Eric

    2015-04-01

    In December 2014, the Electronics class at Millikin University launched a balloon designed to travel into the near-space region of the atmosphere. The balloon was equipped with an instrumentation package including a camera, accelerometer, barometric pressure sensor, temperature probes, as well as a system for tracking using an Automatic Packet Reporting System (APRS). The balloon was launched from Decatur, IL, and landed in Marysville, OH, nearly 320 miles away. The students then analyzed the data from the flight and compared results to expectations.

  10. Accurate Determination of the Volume of an Irregular Helium Balloon

    ERIC Educational Resources Information Center

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  11. Cosmic Balloons

    ERIC Educational Resources Information Center

    El Abed, Mohamed

    2014-01-01

    A team of French high-school students sent a weather balloon into the upper atmosphere to recreate Viktor Hess's historical experiment that demonstrated the existence of ionizing radiation from the sky--later called cosmic radiation. This discovery earned him the Nobel Prize for Physics in 1936.

  12. A Survey of Titan Balloon Concepts and Technology Status

    NASA Technical Reports Server (NTRS)

    Hall, Jeffery L.

    2011-01-01

    This paper surveys the options for, and technology status of, balloon vehicles to explore Saturn's moon Titan. A significant amount of Titan balloon concept thinking and technology development has been performed in recent years, particularly following the spectacular results from the descent and landing of the Huygens probe and remote sensing observations by the Cassini spacecraft. There is widespread recognition that a balloon vehicle on the next Titan mission could provide an outstanding and unmatched capability for in situ exploration on a global scale. The rich variety of revealed science targets has combined with a highly favorable Titan flight environment to yield a wide diversity of proposed balloon concepts. The paper presents a conceptual framework for thinking about balloon vehicle design choices and uses it to analyze various Titan options. The result is a list of recommended Titan balloon vehicle concepts that could perform a variety of science missions, along with their projected performance metrics. Recent technology developments for these balloon concepts are discussed to provide context for an assessment of outstanding risk areas and technological maturity. The paper concludes with suggestions for technology investments needed to achieve flight readiness.

  13. Cryo-balloon catheter localization in fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  14. Introduction (Special Issue on Scientific Balloon Capabilities and Instrumentation)

    NASA Technical Reports Server (NTRS)

    Gaskin, Jessica A.; Smith, I. S.; Jones, W. V.

    2014-01-01

    In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3,000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science.) Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.

  15. Taking the Hot Air Out of Balloons.

    ERIC Educational Resources Information Center

    Brinks, Virgil L.; Brinks, Robyn L.

    1994-01-01

    Describes how a teacher can give their students the challenge of designing and building model balloons or blimps. The project helps students learn the basics of balloon flight and what it really means to be "lighter than air." (PR)

  16. Endovascular balloon-assisted embolization of high-flow peripheral vascular lesions using dual-lumen coaxial balloon microcatheter and Onyx: initial experience.

    PubMed

    Jagadeesan, Bharathi D; Mortazavi, Shabnam; Hunter, David W; Duran-Castro, Olga L; Snyder, Gregory B; Siedel, Glen F; Golzarian, Jafar

    2014-04-01

    Balloon-assisted embolization performed by delivering Onyx ethylene vinyl alcohol copolymer through a dual-lumen coaxial balloon microcatheter is a new technique for the management of peripheral vascular lesions. This technique does not require an initial reflux of Onyx to form around the tip of the microcatheter before antegrade flow of Onyx can commence. In a series of four patients who were treated with the use of this technique, the absence of significant reflux of Onyx was noted, as were excellent navigability and easy retrieval of the balloon microcatheter. However, in one patient, there was inadvertent adverse embolization of a digital artery, which was not caused by reflux of Onyx but could still be related to balloon inflation. © 2013 SIR Published by SIR All rights reserved.

  17. Hurricane Balloon Observations in the Hurricane Inflow Layer

    NASA Astrophysics Data System (ADS)

    Businger, S.; Johnson, R.; Ellis, R.; Talbot, R.

    2005-12-01

    Four autonomous NOAA smart balloons have been prepared at NOAA's Air Resources Lab Field Research Division. The balloons will be released from the northwest corner of Puerto Rico during August and September 2005 into the inflow of tropical cyclones passing just to the north or south of the island. Ballast control allows the balloons to be positioned low in the atmosphere in the inflow of the storms. Observations will include aspirated temperature and humidity, barometric pressure, GPS position, rain rate, ozone, downward IR temperature, and solar radiation. The observations will be transmitted in real time via satellite cellular telephone and posted to the web. Preliminary results of the analysis of the balloon data sets will be presented, including energy content of the inflow air, estimates of surface fluxes, and evidence of organized eddies. Solar cells will help prolong battery life. If a balloon survives an eye-wall penetration, data on the energy content and ozone concentrations of the boundary layer air in the eye will be presented.

  18. Balloons on Ice: NASA Launches Antarctica Scientific Balloon Campaign

    NASA Image and Video Library

    2017-12-08

    Cosmic rays and the chemicals and atoms that make up the interstellar space between stars are the focus of this year’s NASA Antarctica Long Duration Balloon Flight Campaign, which kicked into high gear with the launch of the Boron And Carbon Cosmic rays in the Upper Stratosphere (BACCUS) payload Nov. 28. The University of Maryland’s BACCUS mission is the first of three payloads taking flight from a balloon launch site on Antarctica’s Ross Ice Shelf near McMurdo Station with support from the National Science Foundation’s United States Antarctic Program. Read more: go.nasa.gov/2gCMtyP NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  19. Controlled weather balloon ascents and descents for atmospheric research and climate monitoring

    PubMed Central

    Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.

    2017-01-01

    In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth’s surface to about 35 km (3–5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent. PMID:29263765

  20. Controlled weather balloon ascents and descents for atmospheric research and climate monitoring.

    PubMed

    Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F; Hall, Emrys G; Jordan, Allen F

    2016-01-01

    In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.

  1. Stratospheric Balloon Platforms for Near Space Access

    NASA Astrophysics Data System (ADS)

    Dewey, R. G.

    2012-12-01

    For over five decades, high altitude aerospace balloon platforms have provided a unique vantage point for space and geophysical research by exposing scientific instrument packages and experiments to space-like conditions above 99% of Earth's atmosphere. Reaching altitudes in excess of 30 km for durations ranging from hours to weeks, high altitude balloons offer longer flight durations than both traditional sounding rockets and emerging suborbital reusable launch vehicles. For instruments and experiments requiring access to high altitudes, engineered balloon systems provide a timely, responsive, flexible, and cost-effective vehicle for reaching near space conditions. Moreover, high altitude balloon platforms serve as an early means of testing and validating hardware bound for suborbital or orbital space without imposing space vehicle qualifications and certification requirements on hardware in development. From float altitudes above 30 km visible obscuration of the sky is greatly reduced and telescopes and other sensors function in an orbit-like environment, but in 1g. Down-facing sensors can take long-exposure atmospheric measurements and images of Earth's surface from oblique and nadir perspectives. Payload support subsystems such as telemetry equipment and command, control, and communication (C3) interfaces can also be tested and operationally verified in this space-analog environment. For scientific payloads requiring over-flight of specific areas of interests, such as an active volcano or forest region, advanced mission planning software allows flight trajectories to be accurately modeled. Using both line-of-sight and satellite-based communication systems, payloads can be tracked and controlled throughout the entire mission duration. Under NASA's Flight Opportunities Program, NSC can provide a range of high altitude flight options to support space and geophysical research: High Altitude Shuttle System (HASS) - A balloon-borne semi-autonomous glider carries

  2. New concepts for interplanetary balloons and blimps, particularly for Titan

    NASA Astrophysics Data System (ADS)

    Nott, J.

    This paper proposes novel approaches for balloons for planets Titan BALLUTE A balloon or blimp arriving at a planet or moon with an atmosphere might inflate falling under a parachute or after landing Neither is ideal In both cases the envelope must include qualities needed for inflation as well as those for flight A ballute BALLoon parachUTE could be used thus a ballute is like a hot air balloon with a large mouth Initially it fills by ram pressure descending through an atmosphere As proposed it would then be heated by solid propellant It would stop descending and float level with hot air lift It is now a perfect location for inflation without wind or movement through the atmosphere and away from the uncertainties of the surface A ballute could be used over several bodies in the solar system BALLOONS FOR LOW TEMPERATURES Flight in very low temperatures is also discussed Conditions are so different that it is useful to examine basic factors These apply for any planet with low temperature and weather calm enough for balloons or blimps First for terrestrial hot air balloons thermal radiation is usually the dominant way heat is lost But radiation rises with the 4th power of absolute temperature At Titan radiation will be one or two orders of magnitude smaller Also the dense atmosphere allows small balloons small temperature differences So convection is small It appears a hot air balloon can easily be heated by a radioactive source likely carried to make electricity Pinholes are not important in such a balloon

  3. Reduction of prostate intrafraction motion using gas-release rectal balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su Zhong; Zhao Tianyu; Li Zuofeng

    2012-10-15

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated withmore » the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.« less

  4. Discriminative stimulus properties of intragastrically administered d-amphetamine and pentobarbital in rhesus monkeys.

    PubMed

    de la Garza, R; Johanson, C E

    1987-12-01

    Rhesus monkeys were trained to discriminate intragastrically administered d-amphetamine (AMPH) or pentobarbital (PENTO) from saline using a signaled shock-avoidance trail procedure. All monkeys maintained criterion levels (greater than 90% drug-appropriate responding) throughout the duration of the study during training sessions. In the AMPH experiment, the anorectics diethylpropion, mazindol, phendimetrazine, phenmetrazine and phentermine completely substituted for the training dose of AMPH. The atypical antidepressant bupropion and the psychomotor stimulant methylphenidate also completely substituted for AMPH. Other anorectics including benzphetamine, clortermine, fenetylline, mefenorex and the psychomotor stimulant pemoline that share some pharmacological properties with AMPH substituted for AMPH in some, but not all, of the monkeys tested. The anorectics fenfluramine and chlorphentermine failed to substitute for AMPH. Drugs from other pharmacological classes such as morphine, diazepam, nortripyline and PENTO also failed to substitute for AMPH, indicating pharmacological specificity. In the PENTO experiment, the benzodiazepines alprazolam, bromazepam, diazepam, flurazepam, halazepam, lorazepam, midazolam, oxazepam, temazepam and triazolam and the sedatives methaqualone and phenobarbital completely substituted for the training dose of PENTO. The nonbenzodiazepine anxiolytic CL 218,872 only partially substituted for PENTO. In addition, morphine and AMPH failed to substitute for PENTO, indicating pharmacological specificity. In summary, drugs delivered intragastrically functioned as discriminative stimuli in a drug-class specific manner. The ability to use drugs delivered by this route as discriminative stimuli provides a way to compare anorectic drugs to AMPH or sedative drugs to PENTO under conditions that resemble the mode of human consumption to determine whether these drugs are likely to be associated with AMPH-like or PENTO-like drug dependence.

  5. Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.

    PubMed

    Ro, Andrew J; Davé, Vipul

    2013-03-01

    Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Static and quasi-static analysis of lobed-pumpkin balloon

    NASA Astrophysics Data System (ADS)

    Nakashino, Kyoichi; Sasaki, Makoto; Hashimoto, Satoshi; Saito, Yoshitaka; Izutsu, Naoki

    The present study is motivated by the need to improve design methodology for super pressure balloon with 3D gore design concept, currently being developed at the Scientific Balloon Center of ISAS/JAXA. The distinctive feature of the 3-D gore design is that the balloon film has excess materials not only in the circumferential direction but also in the meridional direction; the meridional excess is gained by attaching the film boundaries to the corresponding tendons of a shorter length with a controlled shortening rate. The resulting balloon shape is a pumpkin-like shape with large bulges formed between adjacent tendons. The balloon film, when fully inflated, develops wrinkles in the circumferential direction over its entire region, so that the stresses in the film are limited to a small amount of uniaxial tension in the circumferential direction while the high meridional loads are carried by re-enforced tendons. Naturally, the amount of wrinkling in the film is dominated by the shortening rate between the film boundaries and the tendon curve. In the 3-D gore design, as a consequence, the shortening rate becomes a fundamental design parameter along with the geometric parameters of the gore. In view of this, we have carried out a series of numerical study of the lobed-pumpkin balloon with varying gore geometry as well as with varying shortening rate. The numerical simula-tions were carried out with a nonlinear finite element code incorporating the wrinkling effect. Numerical results show that there is a threshold value for the shortening rate beyond which the stresses in the balloon film increases disproportionately. We have also carried out quasi-static simulations of the inflation process of the lobed-pumpkin balloon, and have obtained asymmetric deformations when the balloon films are in uniaxial tension state.

  7. 14 CFR 101.39 - Balloon position reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Balloon position reports. 101.39 Section 101.39 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE...

  8. 14 CFR 101.39 - Balloon position reports.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Balloon position reports. 101.39 Section 101.39 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE...

  9. 14 CFR 101.39 - Balloon position reports.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Balloon position reports. 101.39 Section 101.39 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE...

  10. 14 CFR 101.39 - Balloon position reports.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Balloon position reports. 101.39 Section 101.39 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE...

  11. 14 CFR 101.39 - Balloon position reports.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Balloon position reports. 101.39 Section 101.39 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE...

  12. The balloon and the airship technological heritage

    NASA Technical Reports Server (NTRS)

    Mayer, N. J.

    1981-01-01

    The balloon and the airship are discussed with emphasis on the identification of commonalities and distinctions. The aerostat technology behind the shape and structure of the vehicles is reviewed, including a discussion of structural weight, internal pressure, buckling, and the development of a stable tethered balloon system. Proper materials for the envelope are considered, taking elongation and stress into account, and flight operation and future developments are reviewed. Airships and tethered balloons which are designed to carry high operating pressure with low gas loss characteristics are found to share similar problems in low speed flight operations, while possessing interchangeable technologies.

  13. Development of a super-pressure balloon with a diamond-shaped net

    NASA Astrophysics Data System (ADS)

    Saito, Y.; Iijima, I.; Matsuzaka, Y.; Matsushima, K.; Tanaka, S.; Kajiwara, K.; Shimadu, S.

    2014-10-01

    The essential reason of the lobed-pumpkin shaped super-pressure balloon to withstand against the high pressure is that the local curvature of the balloon film is kept small. Recently, it has been found that the small local curvature can also be obtained if the balloon is covered by a diamond-shaped net with a vertically elongated shape. The development of the super-pressure balloon using this method was started from a 3-m balloon with a polyethylene film covered by a net using Kevlar ropes. The ground inflation test showed the expected high burst pressure. Then, a 6-m and a 12-m balloon using a polyethylene film and a net using the Vectran were developed and stable deployment was checked through the ground inflation tests. The flight test of a 3000 m3 balloon was performed in 2013 and shown to resist a pressure of at least 400 Pa. In the future, after testing a new design to relax a possible stress concentration around the polar area, test flights of scaled balloons will be performed gradually enlarging their size. The goal is to launch a 300,000 m3 super-pressure balloon.

  14. Progression of Parkinson's Disease Pathology Is Reproduced by Intragastric Administration of Rotenone in Mice

    PubMed Central

    Pan-Montojo, Francisco; Anichtchik, Oleg; Dening, Yanina; Knels, Lilla; Pursche, Stefan; Jung, Roland; Jackson, Sandra; Gille, Gabriele; Spillantini, Maria Grazia; Reichmann, Heinz; Funk, Richard H. W.

    2010-01-01

    In patients with Parkinson's disease (PD), the associated pathology follows a characteristic pattern involving inter alia the enteric nervous system (ENS), the dorsal motor nucleus of the vagus (DMV), the intermediolateral nucleus of the spinal cord and the substantia nigra, providing the basis for the neuropathological staging of the disease. Here we report that intragastrically administered rotenone, a commonly used pesticide that inhibits Complex I of the mitochondrial respiratory chain, is able to reproduce PD pathological staging as found in patients. Our results show that low doses of chronically and intragastrically administered rotenone induce alpha-synuclein accumulation in all the above-mentioned nervous system structures of wild-type mice. Moreover, we also observed inflammation and alpha-synuclein phosphorylation in the ENS and DMV. HPLC analysis showed no rotenone levels in the systemic blood or the central nervous system (detection limit [rotenone]<20 nM) and mitochondrial Complex I measurements showed no systemic Complex I inhibition after 1.5 months of treatment. These alterations are sequential, appearing only in synaptically connected nervous structures, treatment time-dependent and accompanied by inflammatory signs and motor dysfunctions. These results strongly suggest that the local effect of pesticides on the ENS might be sufficient to induce PD-like progression and to reproduce the neuroanatomical and neurochemical features of PD staging. It provides new insight into how environmental factors could trigger PD and suggests a transsynaptic mechanism by which PD might spread throughout the central nervous system. PMID:20098733

  15. Balloon-Inflated Catheters for Enteral Feeding: a Word of Caution.

    PubMed

    Dash, Nihar Ranjan; Singh, Anand Narayan; Kilambi, Ragini

    2018-02-01

    Catheters with inflatable balloons such as a Foley catheter may be used for feeding gastrostomy/jejunostomy. The incorrect or improper use of these catheters can have serious consequences. We report 13 cases of feeding jejunostomy with balloon-inflated catheter's malfunction, some referred to our centre and others operated here over a period of 8 years. The most dramatic consequence of such improper use led to rupture of the small intestine due to inadvertent over-inflation (over 100 ml) of the balloon of the catheter during a contrast study. The patient required a laparotomy with resection and anastomosis of the bowel. Three other patients had similar over-inflation of the balloon leading to severe pain and discomfort. In all three patients, timely deflation of the balloon was sufficient to relieve the symptoms. One patient had intussusception with the inflated balloon acting as a lead point. The patient underwent resection of the small bowel with end jejunostomy and distal mucous fistula. All other patients presented with abdominal pain and distension and intestinal obstruction and were managed non-operatively with deflation of balloon either by aspiration, cutting the balloon port or ultrasound-guided puncture of balloon. Healthcare personnel dealing with patients with indwelling catheters must be educated to suspect, detect and manage such problems. The best measure for such unusual complications of otherwise safe devices would be prevention by training and generation of awareness.

  16. Development of a Compact Captive Balloon and Its Level Supporting

    NASA Astrophysics Data System (ADS)

    Nakao, Tatsuya; Fujiwara, Kazuhito; Furukawa, Motoyasu; Hiroe, Tetsuyuki

    Many kinds of observation techniques have been developed to obtain the properties of atmospheric conditions. The advanced observation techniques of the flow in relatively large scale are remote sensing by satellite facilities, long range observations by radar or Doppler Sodar, etc., while data from conventional climometers set at fixed places are merely limited information about local scale flow. Captive balloons are also available and feasible for the observation of local flows if their standing mechanics are robust against the strong wind and the motion of balloon are stable for all wind direction and the change of wind direction. In this paper, a compact captive balloon (about 2m diam.) for flow measurement is proposed and the preservation of balloon height level and the stabilization of its motion are challenged by using a kite. The relation between force balances acted on the balloon and the balloon height or position was estimated and confirmed in experiments. Although the lift force of single kite worked successfully, it is found that the performance of plural kites is less in the traction of balloon since the interaction of their tensions. The compact balloon supported by the kite enabled the over 300m floating by virtue of the small size causing only low air resistance.

  17. False coronary dissection with the new Monorail angioplasty balloon catheter.

    PubMed

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  18. Sounding rocket and balloon flight safety philosophy and methodologies

    NASA Technical Reports Server (NTRS)

    Beyma, R. J.

    1986-01-01

    NASA's sounding rocket and balloon goal is to successfully and safely perform scientific research. This is reflected in the design, planning, and conduct of sounding rocket and balloon operations. The purpose of this paper is to acquaint the sounding rocket and balloon scientific community with flight safety philosophy and methodologies, and how range safety affects their programs. This paper presents the flight safety philosophy for protecting the public against the risk created by the conduct of sounding rocket and balloon operations. The flight safety criteria used to implement this philosophy are defined and the methodologies used to calculate mission risk are described.

  19. Intragastric administration of leucine or isoleucine lowers the blood glucose response to a mixed-nutrient drink by different mechanisms in healthy, lean volunteers.

    PubMed

    Ullrich, Sina S; Fitzgerald, Penelope Ce; Schober, Gudrun; Steinert, Robert E; Horowitz, Michael; Feinle-Bisset, Christine

    2016-11-01

    The branched-chain amino acids leucine and isoleucine lower blood glucose after oral glucose ingestion, and the intraduodenal infusion of leucine decreases energy intake in healthy, lean men. We investigated the effects of the intragastric administration of leucine and isoleucine on the gastric emptying of, and blood glucose responses to, a physiologic mixed-macronutrient drink and subsequent energy intake. In 2 separate studies, 12 healthy, lean subjects received on 3 separate occasions an intragastric infusion of 5 g leucine (leucine-5g) or an intragastric infusion of 10 g leucine (leucine-10g), an intragastric infusion of 5 g isoleucine (isoleucine-5g) or an intragastric infusion of 10 g isoleucine (isoleucine-10g), or a control. Fifteen minutes later, subjects consumed a mixed-nutrient drink (400 kcal, 56 g carbohydrates, 15 g protein, and 12 g fat), and gastric emptying ( 13 C-acetate breath test) and blood glucose, plasma insulin, C-peptide, glucagon, glucagon-like peptide-1 (GLP-1), glucose-dependent insulinotropic polypeptide (GIP), and cholecystokinin (leucine study only) were measured for 60 min. Immediately afterward, energy intake from a cold, buffet-style meal was assessed. Compared with the control, leucine-10g decreased the blood glucose area under the curve (AUC) (P < 0.05) and tended to reduce peak blood glucose (P = 0.07), whereas effects of leucine-5g were NS. Leucine-10g, but not leucine-5g, increased plasma insulin and C-peptide AUCs (P < 0.01 for both), but neither dose affected glucagon, GLP-1, GIP, cholecystokinin, gastric emptying, or energy intake. Compared with the control, isoleucine-10g reduced the blood glucose AUC and peak blood glucose (P < 0.01), whereas effects of isoleucine-5g were NS. Neither load affected insulin, C-peptide, glucagon, GLP-1, or GIP. Isoleucine-10g, but not isoleucine-5g, slowed gastric emptying (P < 0.05), but gastric emptying was not correlated with the blood glucose AUC. Isoleucine did not affect energy intake

  20. Gastric emptying and intragastric distribution of lipids in man. A new scintigraphic method of study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jian, R.; Vigneron, N.; Najean, Y.

    1982-08-01

    We measured gastric emptying of fat and water from a solid-liquid meal in healthy volunteers using a tubeless scintigraphic method. /sup 75/Se glycerol triether, incorporated in butter, was the lipid-phase marker, and /sup 99m/Tcm, ingested with 250 ml water, the non-lipid phase marker. In seven of these subjects we also measured the gastric emptying of solids and liquids with /sup 99m/Tc bound to cooked egg whites as the solid-phase marker and /sup 111/In ingested with 250 ml water as the marker of the solid and aqueous phases. Emptying and intragastric repartition of each marker were measured by detection of radioactivitymore » changes over the abdominal area using a gamma-camera. The stability and the specificity of the labeling was checked for each marker. Mean gastric emptying rate (expressed as percentage ingested marker emptied per hr) of lipids (17.4 +/- 2.4) was much lower than that of the rest of the meal (34.2 +/- 1.8) and slightly, but significantly, lower than that of solids (22.8 +/- 1.8). An intragastric layering of fat above nonlipids was observed only after the first postprandial hour and remained moderate. Thus, lipids are emptied more slowly than any other component of an ordinary meal, and this is not due only to layering of fat above water.« less

  1. Balloon Sculpture

    ERIC Educational Resources Information Center

    Warwick, James F.

    1976-01-01

    For the adventurous teacher and student there is an alternative to the often messy mixing, pouring, casting, cutting, scoring and sanding of plaster of Paris for casting or sculptural projects. Balloon sculpture, devised, designed and shown here by a sculptor/teacher, is an eye appealing sculptural form and holds a strong interest for students.…

  2. Drug-eluting balloon angioplasty versus uncoated balloon angioplasty for peripheral arterial disease of the lower limbs.

    PubMed

    Kayssi, Ahmed; Al-Atassi, Talal; Oreopoulos, George; Roche-Nagle, Graham; Tan, Kong Teng; Rajan, Dheeraj K

    2016-08-04

    Atherosclerotic peripheral arterial disease (PAD) can lead to disabling ischemia and limb loss. Treatment modalities have included risk factor optimization through life-style modifications and medications, or operative approaches using both open and minimally invasive techniques, such as balloon angioplasty. Drug-eluting balloon (DEB) angioplasty has emerged as a promising alternative to uncoated balloon angioplasty for the treatment of this difficult disease process. By ballooning and coating the inside of atherosclerotic vessels with cytotoxic agents, such as paclitaxel, cellular mechanisms responsible for atherosclerosis and neointimal hyperplasia are inhibited and its devastating complications are prevented or postponed. DEBs are considerably more expensive than uncoated balloons, and their efficacy in improving patient outcomes is unclear. To assess the efficacy of drug-eluting balloons (DEBs) compared with uncoated, nonstenting balloon angioplasty in people with symptomatic lower-limb peripheral arterial disease (PAD). The Cochrane Vascular Trials Search Co-ordinator (TSC) searched the Specialised Register (last searched December 2015) and Cochrane Register of Studies (CRS) (2015, Issue 11). The TSC searched trial databases for details of ongoing and unpublished studies. We included all randomized controlled trials that compared DEBs with uncoated, nonstenting balloon angioplasty for intermittent claudication (IC) or critical limb ischemia (CLI). Two review authors (AK, TA) independently selected the appropriate trials and performed data extraction, assessment of trial quality, and data analysis. The senior review author (DKR) adjudicated any disagreements. Eleven trials that randomized 1838 participants met the study inclusion criteria. Seven of the trials included femoropopliteal arterial lesions, three included tibial arterial lesions, and one included both. The trials were carried out in Europe and in the USA and all used the taxane drug paclitaxel in the

  3. Solar energy collector including a weightless balloon with sun tracking means

    DOEpatents

    Hall, Frederick F.

    1978-01-01

    A solar energy collector having a weightless balloon, the balloon including a transparent polyvinylfluoride hemisphere reinforced with a mesh of ropes secured to its outside surface, and a laminated reflector hemisphere, the inner layer being clear and aluminized on its outside surface and the outer layer being opaque, the balloon being inflated with lighter-than-air gas. A heat collection probe extends into the balloon along the focus of reflection of the reflective hemisphere for conducting coolant into and out of the balloon. The probe is mounted on apparatus for keeping the probe aligned with the sun's path, the apparatus being founded in the earth for withstanding wind pressure on the balloon. The balloon is lashed to the probe by ropes adhered to the outer surface of the balloon for withstanding wind pressures of 100 miles per hour. Preferably, the coolant is liquid sodium-potassium eutectic alloy which will not normally freeze at night in the temperate zones, and when heated to 4,000.degree. R exerts a pressure of only a few atmospheres.

  4. Strengths of balloon films with flaws and repairs

    NASA Technical Reports Server (NTRS)

    Portanova, M. A.

    1989-01-01

    The effects of manufacture flaws and repairs in high altitude scientific balloons was examined. A right circular cylinder was used to induce a biaxial tension-tension stress field in the polyethlene film used to manufacture these balloons. A preliminary investigation of the effect that cylinder geometry has on stress rate as a function of inflation rate was conducted. The ultimate goal was to rank, by order of degrading effects, the flaws and repairs commonly found in current high altitude balloons.

  5. Innovations in Balloon Catheter Technology in Rhinology.

    PubMed

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    Some of the BARREL balloon launches took place at the South African National Antarctic Expedition Research base, called SANAE IV, the others at Halley Research Station. This balloon is taking flight at SANAE IV. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA

  7. Fluorescence Lyman-Alpha Stratospheric Hygrometer (FLASH): application on meteorological balloons, long duration balloons and unmanned aerial vehicles.

    NASA Astrophysics Data System (ADS)

    Lykov, Alexey; Khaykin, Sergey; Yushkov, Vladimir; Efremov, Denis; Formanyuk, Ivan; Astakhov, Valeriy

    The FLASH instrument is based on the fluorescent method, which uses H2O molecules photodissociation at a wavelength lambda=121.6 nm (Lalpha - hydrogen emission) followed by the measurement of the fluorescence of excited OH radicals. The source of Lyman-alpha radiation is a hydrogen discharge lamp while the detector of OH fluorescence at 308 -316 nm is a photomultiplier run in photon counting mode. The intensity of the fluorescent light as well as the instrument readings is directly proportional to the water vapor mixing ratio under stratospheric conditions with negligible oxygen absorption. Initially designed for rocket-borne application, FLASH has evolved into a light-weight balloon sonde (FLASH-B) for measurements in the upper troposphere and stratosphere on board meteorological and small plastic balloons. This configuration has been used in over 100 soundings at numerous tropical mid-latitude and polar locations within various international field campaigns. An airborne version of FLASH instrument is successfully utilized onboard stratospheric M55-Geophysica aircraft and tropospheric airborne laboratory YAK42-Roshydromet. The hygrometer was modified for application onboard stratospheric long-duration balloons (FLASH-LDB version). This version was successfully used onboard CNES super-pressure balloon launched from SSC Esrange in March 2007 and flown during 10 days. Special design for polar long duration balloon PoGOLite was created for testing work during polar day in June 2013. Installation and measurement peculiarities as well as observational results are presented. Observations of water vapour using FLASH-B instrument, being of high quality are rather costly as the payload recovery is often complicated and most of the time impossible. Following the goal to find a cost-efficient solution, FLASH was adapted for use onboard Unmanned Aerial Vehicles (UAV). This solution was only possible thanks to compactness and light-weight (0.5 kg) of FLASH instrument. The

  8. The Latest Developments in NASA's Long Duration Balloon Systems

    NASA Astrophysics Data System (ADS)

    Stilwell, Bryan D.

    The Latest Developments in NASA’s Long Duration Balloon Systems Bryan D. Stilwell, bryan.stilwell@csbf.nasa.gov Columbia Scientific Balloon Facility, Palestine, Texas, USA The Columbia Scientific Balloon Facility, located in Palestine, Texas offers the scientific community a high altitude balloon based communications platform. Scientific payload mass can exceed 2722 kg with balloon float altitudes on average of 40000 km and flight duration of up to 100 days. Many developments in electrical systems have occurred over the more than 25 years of long duration flights. This paper will discuss the latest developments in electronic systems related to long duration flights. Over the years, the long duration flights have increased in durations exceeding 56 days. In order to support these longer flights, the systems have had to increase in complexity and reliability. Several different systems that have been upgraded and/or enhanced will be discussed.

  9. Balloon Program Wraps up in Antarctica, Heading to New Zealand

    NASA Image and Video Library

    2015-02-02

    Caption: A NASA Super Pressure Balloon with the COSI payload is ready for launch from McMurdo, Antarctica. Credit: NASA More info: NASA’s globetrotting Balloon Program Office is wrapping up its 2014-2015 Antarctic campaign while prepping for an around-the-world flight launching out of Wanaka, New Zealand, in March. After 16 days, 12 hours, and 56 minutes of flight, operators successfully conducted a planned flight termination of the Suborbital Polarimeter for Inflation Dust and the Epoch of Reionization (SPIDER) mission Saturday, Jan. 18, the final mission of the campaign. Other flights in the 2014-2015 Antarctic campaign included the Antarctic Impulsive Transient Antenna (ANITA-III) mission as well as the Compton Spectrometer and Imager (COSI) payload flown on the developmental Super Pressure Balloon (SPB). ANITA-III successfully wrapped up Jan. 9 after 22 days, 9 hours, and 14 minutes of flight. Flight controllers terminated the COSI flight 43 hours into the mission after detecting a small gas leak in the balloon. Crews are now working to recover all three instruments from different locations across the continent. The 6,480-pound SPIDER payload is stationary at a position about 290 miles from the United Kingdom’s Sky Blu Logistics Facility in Antarctica. The 4,601 pound ANITA-III payload, located about 100 miles from Australia’s Davis Station, and the 2,866 pound COSI payload, located about 340 miles from the United States McMurdo Station both had numerous key components recovered in the past few days. Beginning in late January, the Balloon Program Office will deploy a team to Wanaka, New Zealand, to begin preparations for an SPB flight, scheduled to launch in March. The Program Office seeks to fly the SPB more than 100 days, which would shatter the current flight duration record of 55 days, 1 hour, and 34 minutes for a large scientific balloon. “We’re looking forward to the New Zealand campaign and hopefully a history-making flight with the Super

  10. Evaluation of balloon withdrawal forces with bare-metal stents, compared with Taxus and Cypher drug-eluting coronary stents: balloon, stent and polymer interactions.

    PubMed

    Turk, Marvee; Gupta, Vishal; Fischell, Tim A

    2010-03-01

    There have been reports of serious complications related to difficulty removing the deflated Taxus stent delivery balloon after stent deployment. The purpose of this study was to determine whether the Taxus SIBS polymer was "sticky" and associated with an increase in the force required to remove the stent delivery balloon after stent deployment, using a quantitative, ex-vivo model. Balloon-polymer-stent interactions during balloon withdrawal were measured with the Taxus Liberté, Liberté bare-metal stent (BMS; no polymer = control), the Cordis Cypher drug-eluting stent (DES; PEVA/PBMA polymer) and the BX Velocity (no polymer). We quantitatively measured the force required to remove the deflated stent delivery balloon from each of these stents in simulated vessels at 37 degrees C in a water bath. Balloon withdrawal forces were measured in straight (0 degree curve), mildly curved (20 degree curve) and moderately curved (40 degree curve) simulated vessel segments. The average peak force required to remove the deflated balloon catheter from the Taxus Liberté DES, the Liberté BMS, the Cypher DES, and the Bx Velocity BMS were similar in straight segments, but were much greater for the Taxus Liberté in the moderately curved segments (1.4 lbs vs. 0.11 lbs, 0.11 lbs and 0.12 lbs, respectively; p < 0.0001). The SIBS polymer of the Taxus Liberté DES appears to be "sticky" and is associated with high forces required to withdraw the deflated balloon from the deployed stent in curved segments. This withdrawal issue may help to explain the clinical complications that have been reported with this device.

  11. Inquiry-Based Early Undergraduate Research Using High-Altitude Ballooning

    NASA Astrophysics Data System (ADS)

    Sibbernsen, K.; Sibbernsen, M.

    2012-12-01

    One common objective for undergraduate science classes is to have students learn how to do scientific inquiry. However, often in science laboratory classes, students learn to take data, analyze the data, and come to conclusions, but they are told what to study and do not have the opportunity to ask their own research questions, a crucial part of scientific inquiry. A special topics class in high-altitude ballooning (HAB) was offered at Metropolitan Community College, a large metropolitan two-year college in Omaha, Nebraska to focus on scientific inquiry for the participants through support of NASA Nebraska Space Grant. A weather balloon with payloads attached (balloonSAT) was launched to near space where the balloon burst and fell back to the ground with a parachute. Students worked in small groups to ask their research questions, they designed their payloads, participated in the launch and retrieval of equipment, analyzed data, and presented the results of their research. This type of experience has potential uses in physics, physical science, engineering, electronics, computer programming, meteorology, astronomy, and chemistry classes. The balloonSAT experience can act as a stepping-stone to designing sounding rocket payloads and it can allow students the opportunity to participate in regional competitions and present at HAB conferences. Results from the workshop are shared, as well as student responses to the experience and suggestions for administering a high-altitude ballooning program for undergraduates or extending inquiry-based ballooning experiences into high-school or middle-school.

  12. Hybrid Global Communication Architecture with Balloons and Satellites

    NASA Astrophysics Data System (ADS)

    Pignolet, G.; Celeste, A.; Erb, B.

    2002-01-01

    Global space communication systems have been developed now for more than three decades, based mainly on geostationary satellites or almost equivalent systems such as the Molnya orbit concepts. The last decade of the twentieth century has seen the emergence of satellite constellations in low or medium Earth orbit, in order to improve accessibility in terms of visibility at higher latitudes and limited size or power requirement for ground equipment. However such systems are complex to operate, there are still many situations where connection may remain difficult to achieve, and commercial benefits are still to be proven. A new concept, using a network combination of geostationary relay satellites and high altitude stratospheric platforms may well overcome the inconveniences of both geostationary systems and satellite constellations to improve greatly global communication in the future. The emergence of enabling technologies developed in Japan and in several other countries will soon make it possible to fly helium balloons in the upper layers of the atmosphere, at altitudes of 20 km or more. At such an altitude, well above the meteorological disturbances and the jet-streams, the stratosphere enjoys a regular wind at moderate speeds ranging between 10 m/s and 30 m/s, depending on latitude and also on season. It is possible for balloons powered by electric engines to fly non- stop upstream of the wind in order to remain stationary above a particular location. Large balloons, with sizes up to 300 m in length, would be able to carry sub-satellite communication payloads, as well as observation apparatus and scientific equipment. The range of visibility for easy both-way communication between the balloon and operators or customers on the ground could be as large as 200 km in radius. Most current studies consider a combination of solar cells and storage batteries to power the balloons, but microwave beam wireless power transportation from the ground could be a very

  13. Crash in Australian outback ends NASA ballooning season

    NASA Astrophysics Data System (ADS)

    Harris, Margaret

    2010-06-01

    NASA has temporarily suspended all its scientific balloon launches after the balloon-borne Nuclear Compton Tele scope (NCT) crashed during take-off, scattering a trail of debris across the remote launch site and overturning a nearby parked car.

  14. Advances in the Remote Monitoring of Balloon Flights

    NASA Astrophysics Data System (ADS)

    Breeding, S.

    At the National Scientific Balloon Facility (NSBF), we must staff the Long Duration Balloon (LDB) control center 24 hours a day during LDB flights. This requires three daily shifts of two operators (balloon control and tdrss scheduling). In addition to this we also have one engineer on-call as LDB Lead to resolve technical issues and one manager on-call for flight management. These on-call periods are typically 48 to 72 hours in length. In the past the on-call staff had to travel to the LDB control center in order to monitor the status of a flight in any detail. This becomes problematic as flight durations push out beyond 20 to 30 day lengths, as these staff members are not available for business travel during these periods. This paper describes recent advances which allow for the remote monitoring of scientific balloon flight ground station computer displays. This allows balloon flight managers and lead engineers to check flight status and performance from any location with a network or telephone connection. This capability frees key personnel from the NSBF base during flights. It also allows other interested parties to check on the flight status at their convenience.

  15. Wind-Driven Montgolfiere Balloons for Mars

    NASA Technical Reports Server (NTRS)

    Jones, Jack A.; Fairbrother, Debora; Lemieux, Aimee; Lachenmeier, Tim; Zubrin, Robert

    2005-01-01

    Solar Montgolfiere balloons, or solar-heated hot air balloons have been evaluated by use on Mars for about 5 years. In the past, JPL has developed thermal models that have been confirmed, as well as developed altitude control systems to allow the balloons to float over the landscape or carry ground sampling instrumentation. Pioneer Astronautics has developed and tested a landing system for Montgolfieres. JPL, together with GSSL. have successfully deployed small Montgolfieres (<15-m diameter) in the earth's stratosphere, where conditions are similar to a Mars deployment. Two larger Montgolfieres failed, however, and a series of larger scale Montgolfieres is now planned using stronger, more uniform polyethylene bilaminate, combined with stress-reducing ripstitch and reduced parachute deceleration velocities. This program, which is presently under way, is a joint effort between JPL, WFF, and GSSL, and is planned for completion in three years.

  16. Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.

    PubMed

    Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik

    2016-05-01

    Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.

  17. Aerial Deployment and Inflation System for Mars Helium Balloons

    NASA Technical Reports Server (NTRS)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  18. Flavor preferences conditioned by intragastric monosodium glutamate in mice.

    PubMed

    Ackroff, Karen; Sclafani, Anthony

    2013-11-01

    The consumption of monosodium glutamate (MSG) solutions has been shown to reinforce preferences for MSG and for MSG-paired flavors in mice. These effects appear to have a strong postoral component, such that MSG detected in the gut is associated with concurrently consumed flavors. Two experiments investigated postoral MSG reward by infusing 400mM MSG intragastrically (IG) to C57BL/6 mice as they consumed a conditioned stimulus (CS+) flavor. An alternate CS- flavor was paired with IG water. In Experiment 1, the grape and cherry CS flavors were unsweetened, and intakes and preferences for the CS+ flavor were modest. Experiment 2 attempted to generate stronger preferences by adding 0.05% saccharin to the CS flavors. Sweet taste did enhance intakes during training and testing but did not significantly increase percent CS+ intake or persistence of the preference. However, only conditioning with the sweet CS+ resulted in the mice expressing a preference for oral MSG in an initial choice test with water. These findings extend recent studies demonstrating postoral MSG conditioning in rats.

  19. 21 CFR 870.3535 - Intra-aortic balloon and control system

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intra-aortic balloon and control system 870.3535... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3535 Intra-aortic balloon and control system (a) Identification. A intra-aortic balloon and control system is a device that...

  20. 21 CFR 870.3535 - Intra-aortic balloon and control system

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intra-aortic balloon and control system 870.3535... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3535 Intra-aortic balloon and control system (a) Identification. A intra-aortic balloon and control system is a device that...

  1. 21 CFR 870.3535 - Intra-aortic balloon and control system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... syndrome, cardiac and non-cardiac surgery, or complications of heart failure. The special controls for this... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intra-aortic balloon and control system. 870.3535... balloon and control system. (a) Identification. An intra-aortic balloon and control system is a...

  2. Prospects for infrasound bolide detections from balloon-borne platforms

    NASA Astrophysics Data System (ADS)

    Young, Eliot; Bowman, Daniel; Arrowsmith, Stephen; Boslough, Marc; Klein, Viliam; Ballard, Courtney; Lees, Jonathan

    2017-04-01

    We report on an experiment to assess whether balloon-borne instruments can improve sensitivities to bolides exploding in the Earth's atmosphere (essentially using the atmosphere as a witness plate to characterize the small end of the NEO (Near Earth Object) population). The CTBTO's infrasound network regularly detects infrasound disturbances caused by bolides, including the 15-FEB-2013 Chelybinsk impact. Balloon-borne infrasound sensors should have two important advantages over ground-based infrasound stations: there should be virtually no wind noise on a free-floating platform, and a sensor in the stratosphere should benefit from its location within the stratospheric duct. Balloon-borne sensors also have the disadvantage that the amplitude of infrasound waves will decrease as they ascend with altitude. To test the performance of balloon-borne sensors, we conducted an experiment on a NASA high altitude (35 km) balloon launched from Ft Sumner, NM on 28-SEP-2016. We were able to put two independent infrasound payloads on this flight. We arranged for three 3000-lb ANFO explosions to be detonated from Socorro, NM at 12:00, 14:00 and 16:29:59 MST. The first two explosions were detected from the NASA balloon, with the first explosion showing three separate waveforms arriving within a 25-s span. The peak-to-peak amplitude of the waveforms was about 0.06 Pa, and the cleanest microphone channel detected this waveform with an SNR greater than 20. A second balloon at 15 km altitude also detected the second explosion. We have signals from a dozen ground stations at various positions from Socorro to Ft Sumner. We will report on wave propagation models and how they compare with observations from the two balloons and the various ground-stations.

  3. Balloon valvuloplasty of congenital mitral stenosis.

    PubMed

    Arndt, Jason W; Oyama, Mark A

    2013-06-01

    Radiographic, echocardiographic, fluoroscopic, and angiographic images from 2 dogs with severe congenital mitral valve stenosis that underwent cardiac catheterization and balloon valvuloplasty are presented. Both dogs displayed systolic doming of the mitral valve leaflets, increased diastolic pressure gradient across the left atrium and ventricle, and decreased mitral inflow E to F slope. Balloon valvuloplasty was performed on both dogs using atrial transeptal puncture. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. A balloon-borne experiment to investigate the Martian magnetic field

    NASA Astrophysics Data System (ADS)

    Schwingenschuh, K.; Feldhofer, H.; Koren, W.; Jernej, I.; Stachel, M.; Riedler, W.; Slamanig, H.; Auster, H.-U.; Rustenbach, J.; Fornacon, H. K.; Schenk, H. J.; Hillenmaier, O.; Haerendel, G.; Yeroshenko, Ye.; Styashkin, V.; Zaroutzky, A.; Best, A.; Scholz, G.; Russell, C. T.; Means, J.; Pierce, D.; Luhmann, J. G.

    1996-03-01

    The Space Research Institute of the Austrian Academy, of Sciences (Graz, Austria) in cooperation with MPE (Berlin, Germany), GFZ Potsdam (Obs. Niemegk, Germany) IZMIRAN/IOFAN (Moscow, Russian) and IGPP/UCLA (Los Angeles, USA) is designing the magnetic field experiment MAGIBAL (MAGnetic field experiment aboard a martian BALloon) to investigate the magnetic field on the surface of Mars. The dual sensor fluxgate magnetometer is part of the MARS-98/MARS-TOGETHER balloon payload. During a ten days period the balloon will float over a distance of about 2000 km at altitudes between 0 and 4 km. Due to the limited power and telemetry allocation the magnetometer can transmit only one vector per ten seconds and spectral information in the frequency range from 2 - 25 Hz. The dynamic range is +/- 2000 nT. The main scientific objectives of the experiment are: • Determination of the magnetism of the Martian rocks • Investigation of the leakage of the solar wind induced magnetosphere using the correlation between orbiter and balloon observations • Measurement of the magnetic field profile between the orbiter and the surface of Mars during the descent phase of the balloon. Terrestrial test flights with a hot air balloon were performed in order to test the original MAGIBAL equipment under balloon flight conditions.

  5. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    BARREL team members run under the payload as the balloon first takes flight at the SANAE IV research station in Antarctica. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four

  6. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    Pumping helium into the first BARREL balloon to launch from Halley Research Satation. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science

  7. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    A crane lowers two BARREL balloon payloads onto the platform at Halley Research Station in Antarctica. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors

  8. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    Liftoff! A balloon begins to rise over the brand new Halley VI Research Station, which had its grand opening in February 2013. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through

  9. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    Watching a BARREL balloon – and the instruments dangling below – float up over the SANAE IV research base in Antarctica. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four

  10. Development Overview of the Revised NASA Ultra Long Duration Balloon

    NASA Technical Reports Server (NTRS)

    Cathey, H. M.; Gregory, D; Young, L.; Pierce, D.

    2006-01-01

    The development of the National Aeronautics and Space Administration s (NASA) Ultra Long Duration Balloon (ULDB) has made significant strides in addressing the deployment issues experienced in the scaling up of the balloon structure. This paper concentrates on the super-pressure balloon developments that have been, and are currently being planned by the NASA Balloon Program Office at Goddard Space Flight Center s Wallops Flight Facility. The goal of the NASA ULDB development project is to attempt to extend the potential flight durations for large scientific balloon payloads. A summary of the February 2005 test flight from Ft. Sumner, New Mexico will be presented. This test flight spurred a number of investigations and advancements for this project. The development path has pursued some new approaches in the design, analysis, and testing of the balloons. New issues have been ideEti6ed throu& both analysis md testing. These have been addressed in the design stage before the next balloon construction was begun. This paper will give an overview of the recent history for this effort and the development approach pursued for ULDB. A description of the balloon design, including the modifications made as a result of the lessons learned, will be presented. Areas to be presented include the design approach, deployment issues that have been encountered and the proposed solutions, ground testing, photogrammetry, and an analysis overview. Test flight planning and considerations will be presented including test flight safety. An extended duration test flight of the National Aeronautics and Space Administration s Ultra Long Duration Balloon is planned for the May/June 2006 time frame. This flight is expected to fly from Sweden to either Canada or Alaska. Preliminary results of this flight will be presented as available. Future plans for both ground testing and additional test flights will also be presented. Goals of the future test flights, which are staged in increments of

  11. Fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children.

    PubMed

    Hu, Hong-Tao; Shin, Ji Hoon; Kim, Jin-Hyoung; Jang, Jong Keon; Park, Jung-Hoon; Kim, Tae-Hyung; Nam, Deok Ho; Song, Ho-Young

    2015-07-01

    We aimed to evaluate the safety and clinical effectiveness of fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children. Our study included seven children (mean age 4.0 years) who underwent a total of ten balloon dilatation sessions. The initial balloon diameters were 10-15 mm. The technical success, clinical success (improved food intake and reduced dysphagia within 1 month following the first balloon dilatation), dysphagia recurrence, and complications were retrospectively evaluated. Technical and clinical success rates were 100 %. During the mean 38-month follow-up period after the first balloon dilatation, 3 (43 %) patients underwent only one additional balloon dilatation 4-5 months after the first balloon dilatation for dysphagia recurrence. Two of them showed improvement without further recurrence, while the remaining one underwent partial esophagectomy. Well-contained transmural esophageal rupture (type 2) occurred in two (29 %, 2/7) patients and during two (20 %, 2/10) balloon dilatation sessions. All ruptures were successfully treated conservatively. Our study showed that fluoroscopically guided large balloon dilatation seems to be a simple and effective primary treatment technique for congenital esophageal stenosis in children. Esophageal ruptures were not uncommon although they were not fatal.

  12. Esomeprazole 40 mg provides more effective intragastric acid control than lansoprazole 30 mg, omeprazole 20 mg, pantoprazole 40 mg and rabeprazole 20 mg in patients with gastro-oesophageal reflux symptoms.

    PubMed

    Röhss, Kerstin; Lind, Tore; Wilder-Smith, Clive

    2004-10-01

    To compare the effect of esomeprazole 40 mg with lansoprazole 30 mg, omeprazole 20 mg, pantoprazole 40 mg and rabeprazole 20 mg on intragastric pH during single and repeated dosing in four separate studies in patients with symptoms of gastro-oesophageal reflux disorder (GERD). In four randomised crossover studies, patients with symptoms of GERD received once-daily treatment with esomeprazole 40 mg or lansoprazole 30 mg (study A), omeprazole 20 mg (study B), pantoprazole 40 mg (study C) and rabeprazole 20 mg (study D) for 5 days. Continuous 24-h intragastric pH recording was performed on days 1 (except study B) and 5. Percentage of time over 24 h with intragastric pH greater than 4, 24-h median pH and the proportion of patients with pH greater than 4 for greater than or equal to 12 h and 16 h during the 24-h recording periods were investigated. In all four studies, esomeprazole 40 mg OD maintained intragastric pH greater than 4 for a significantly higher mean percentage of the 24-h period compared with all other proton pump inhibitors (PPIs) on days 1 (esomeprazole 40.6% versus lansoprazole 33.4%, P=0.0182; esomeprazole 50.3% versus pantoprazole 29.1%, P<0.001; esomeprazole 41.0% versus rabeprazole 29.4%, P=0.002) and 5 (esomeprazole 57.7% versus lansoprazole 44.5%, P<0.0001; esomeprazole 69.8% versus omeprazole 43.7%, P<0.0001; esomeprazole 67.0% versus pantoprazole 44.8%, P<0.001; esomeprazole 59.4% versus rabeprazole 44.5%, P<0.0001). Higher 24-h median pH and a higher proportion of patients with intragastric pH greater than 4 for greater than or equal to 12 h and 16 h were reported with esomeprazole 40 mg OD than with all the other PPIs in each study. Esomeprazole 40 mg provides greater acid control in more patients and maintains intragastric pH greater than 4 for a longer period than lansoprazole 30 mg, omeprazole 20 mg, pantoprazole 40 mg and rabeprazole 20 mg in patients with symptoms of GERD.

  13. Comparison of the effect of the antacid Rennie versus low-dose H2-receptor antagonists (ranitidine, famotidine) on intragastric acidity.

    PubMed

    Netzer, P; Brabetz-Höfliger, A; Bründler, R; Flogerzi, B; Hüsler, J; Halter, F

    1998-04-01

    Symptoms of functional dyspepsia are common and patients often self-medicate with antacids, or with low-dose H2-antagonists which are available as over-the-counter medications. To date, there has been limited information available comparing the effects on intragastric acidity of these two types of over-the-counter medication. Therefore we studied the effect of the antacid Rennie and two H2-antagonists on the intragastric pH of fasting volunteers. Sixteen healthy, fasting volunteers were randomized into a double-blind, placebo-controlled, four-way crossover study comparing Rennie (calcium-magnesium carbonate) 1360 mg, ranitidine 75 mg, famotidine 10 mg and placebo. Their effect on gastric pH was monitored by a 4-h gastric pH-metry. The primary efficacy parameter was the time lag before an intragastric pH > 3.0 was reached after drug administration. The median time lag before pH > 3.0 was reached after drug administration was 5.8 min for Rennie, 64.9 min for ranitidine, 70.1 min for famotidine and 240.0 min for placebo. The percentage of time with values of pH > 3.0 was 10.4% for Rennie, 61.4% for ranitidine, 56.6% for famotidine and 1.4% for placebo. The onset of action in fasting volunteers was significantly faster with the antacid than with the two H2-antagonists. The duration of action was significantly longer with an H2-antagonist than with the antacid. This suggests that the two products should be used for different indications: antacids are superior for rapid pain relief, whereas H2-antagonists might be better for symptom prophylaxis--for example for nocturnal dyspepsia.

  14. AIAA Educator Academy: The Space Weather Balloon Module

    NASA Astrophysics Data System (ADS)

    Longmier, B.; Henriquez, E.; Bering, E. A.; Slagle, E.

    2013-12-01

    Educator Academy is a K-12 STEM curriculum developed by the STEM K-12 Outreach Committee of the American Institute of Aeronautics and Astronautics (AIAA). Consisting of three independent curriculum modules, K-12 students participate in inquiry-based science and engineering challenges to improve critical thinking skills and enhance problem solving skills. The Space Weather Balloon Curriculum Module is designed for students in grades 9-12. Throughout this module, students learn and refine physics concepts as well as experimental research skills. Students participate in project-based learning that is experimental in nature. Students are engaged with the world around them as they collaborate to launch a high altitude balloon equipped with HD cameras.The program leaders launch high altitude weather balloons in collaboration with schools and students to teach physics concepts, experimental research skills, and to make space exploration accessible to students. A weather balloon lifts a specially designed payload package that is composed of HD cameras, GPS tracking devices, and other science equipment. The payload is constructed and attached to the balloon by the students with low-cost materials. The balloon and payload are launched with FAA clearance from a site chosen based on wind patterns and predicted landing locations. The balloon ascends over 2 hours to a maximum altitude of 100,000 feet where it bursts and allows the payload to slowly descend using a built-in parachute. The payload is located using the GPS device. In April 2012, the Space Weather Balloon team conducted a prototype field campaign near Fairbanks Alaska, sending several student-built experiments to an altitude of 30km, underneath several strong auroral displays. To better assist teachers in implementing one or more of these Curriculum Modules, teacher workshops are held to give teachers a hands-on look at how this curriculum is used in the classroom. And, to provide further support, teachers are each

  15. JACEE long duration balloon flights. [Japanese-American Cooperative Emulsion Experiment

    NASA Technical Reports Server (NTRS)

    Burnett, T.; Iwai, J.; Dake, S.; Derrickson, J.; Fountain, W.; Fuki, M.; Gregory, J.; Hayashi, T.; Holynski, R.; Jones, W. V.

    1989-01-01

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1 to 100A TeV. Experiments with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed.

  16. Status report on the activities of National Balloon Facility at Hyderabad

    NASA Astrophysics Data System (ADS)

    Shankarnarayan, Sreenivasan; S, Sreenivasan; Shankarnarayan, Sreenivasan; Manchanda, R. K.; Subba Rao Jonnalagadda, Venkata; Buduru, Suneelkumar

    National balloon facility at Hyderabad has been mandated to provide launch support for Indian and International scientific balloon experiments and also perform the necessary research and development in the design and fabrication of plastic balloons. In the last 4 years, since our last report, NBF has launched many successful balloon flights for the astronomy payloads and a large number of high altitude GPS Sonde flights at different places in the country. We have also continued our efforts on qualification of raw materials for zero-failure performance of our balloons and major focus on upgrading of various facilities and load-line instrumentation for launching from remote sites. We foresee a surge of balloon based experimental activity for in-situ measurements in atmospheric sciences and concept validation payloads for future space based instruments. A new centre for research in Environmental Sciences and Payload Engineering (ESPE) has also been set up at the National Balloon Facility campus to develop and conduct research in various aspects of Environmental sciences in collaboration with other groups, with a specific goal to identify, development of advanced technologies leading to an improved understanding of the earth system. The Payload Engineering facility is geared to the Design and Fabrication of Micro and Nano Satellites and will act as Inter -University Centre for payload fabrication. In this paper we present an overview of the present and planned activities in scientific ballooning at National Balloon Facility Hyderabad.

  17. Localization of acyl ghrelin- and des-acyl ghrelin-immunoreactive cells in the rat stomach and their responses to intragastric pH.

    PubMed

    Mizutani, Makoto; Atsuchi, Kaori; Asakawa, Akihiro; Matsuda, Norifumi; Fujimura, Masaki; Inui, Akio; Kato, Ikuo; Fujimiya, Mineko

    2009-11-01

    Acyl ghrelin has a 28-amino acid sequence with O-n-octanoyl acid modification at the serine 3 position, whereas des-acyl ghrelin has no octanoyl acid modification. Although these peptides exert different physiological functions, no previous studies have shown the different localization of acyl ghrelin and des-acyl ghrelin in the stomach. Here we have developed an antibody specific for des-acyl ghrelin that does not crossreact with acyl ghrelin. Both acyl ghrelin- and des-acyl ghrelin-immunoreactive cells were distributed in the oxyntic and antral mucosa of the rat stomach, with higher density in the antral mucosa than oxyntic mucosa. Immunofluorescence double staining showed that acyl ghrelin- and des-acyl ghrelin-positive reactions overlapped in closed-type round cells, whereas des-acyl ghrelin-positive reaction was found in open-type cells in which acyl ghrelin was negative. Acyl ghrelin-/des-acyl ghrelin-positive closed-type cells contain obestatin; on the other hand, des-acyl ghrelin-positive open-type cells contain somatostatin. We measured the release of acyl ghrelin and des-acyl ghrelin in vascularly perfused rat stomach by ELISA, and the effects of different intragastric pH levels on the release of each peptide were examined. The release of des-acyl ghrelin from the perfused stomach was greater at pH 2 than at pH 4; however, the release of acyl ghrelin was not affected by intragastric pH. The present study demonstrated the differential localization of acyl ghrelin and des-acyl ghrelin in the rat stomach and their different responses to the intragastric pH.

  18. Proposed techniques for launching instrumented balloons into tornadoes

    NASA Technical Reports Server (NTRS)

    Grant, F. C.

    1971-01-01

    A method is proposed to introduce instrumented balloons into tornadoes by means of the radial pressure gradient, which supplies a buoyancy force driving to the center. Presented are analytical expressions, verified by computer calculations, which show the possibility of introducing instrumented balloons into tornadoes at or below the cloud base. The times required to reach the center are small enough that a large fraction of tornadoes are suitable for the technique. An experimental procedure is outlined in which a research airplane puts an instrumented, self-inflating balloon on the track ahead of the tornado. The uninflated balloon waits until the tornado closes to, typically, 750 meters; then it quickly inflates and spirals up and into the core, taking roughly 3 minutes. Since the drive to the center is automatically produced by the radial pressure gradient, a proper launch radius is the only guidance requirement.

  19. Ozone profiles from tethered balloon measurements in an urban plume experiment

    NASA Technical Reports Server (NTRS)

    Youngbluth, O., Jr.; Storey, R. W.; Clendenin, C. G.; Jones, S.; Leighty, B.

    1981-01-01

    NASA Langley Research Center used two tethered balloon systems to measure ozone in the general area of Norfolk, Va. The large balloon system which has an altitude range of 1,500 meters was located at Wallops Island, Va., and the smaller balloon which has an altitude range of 900 meters was located at Chesapeake, Va. Each balloon system measured ozone, temperature, humidity, wind speed, and wind direction from ground to its maximum altitude. From these measurements and from the location of the balloon sites, areas of ozone generation and ozone transport may be inferred. The measurements which were taken during August 1979 are discussed as well as the measurement techniques.

  20. Balloon-Borne Infrasound Detection of Energetic Bolide Events

    NASA Astrophysics Data System (ADS)

    Young, Eliot F.; Ballard, Courtney; Klein, Viliam; Bowman, Daniel; Boslough, Mark

    2016-10-01

    Infrasound is usually defined as sound waves below 20 Hz, the nominal limit of human hearing. Infrasound waves propagate over vast distances through the Earth's atmosphere: the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization) has 48 installed infrasound-sensing stations around the world to detect nuclear detonations and other disturbances. In February 2013, several CTBTO infrasound stations detected infrasound signals from a large bolide that exploded over Chelyabinsk, Russia. Some stations recorded signals that had circumnavigated the Earth, over a day after the original event. The goal of this project is to improve upon the sensitivity of the CTBTO network by putting microphones on small, long-duration super-pressure balloons, with the overarching goal of studying the small end of the NEO population by using the Earth's atmosphere as a witness plate.A balloon-borne infrasound sensor is expected to have two advantages over ground-based stations: a lack of wind noise and a concentration of infrasound energy in the "stratospheric duct" between roughly 5 - 50 km altitude. To test these advantages, we have built a small balloon payload with five calibrated microphones. We plan to fly this payload on a NASA high-altitude balloon from Ft Sumner, NM in August 2016. We have arranged for three large explosions to take place in Socorro, NM while the balloon is aloft to assess the sensitivity of balloon-borne vs. ground-based infrasound sensors. We will report on the results from this test flight and the prospects for detecting/characterizing small bolides in the stratosphere.

  1. An Overview of the NASA Sounding Rocket and Balloon Programs

    NASA Technical Reports Server (NTRS)

    Eberspeaker, Philip J.; Smith, Ira S.

    2003-01-01

    The U.S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a total of 50 to 60 missions per year in support of the NASA scientific community. These missions support investigations sponsored by NASA's Offices of Space Science, Life and Microgravity Sciences & Applications, and Earth Science. The Goddard Space Flight Center has management and implementation responsibility for these programs. The NASA Sounding Rockets Program provides the science community with payload development support, environmental testing, launch vehicles, and launch operations from fixed and mobile launch ranges. Sounding rockets continue to provide a cost-effective way to make in situ observations from 50 to 1500 km in the near-earth environment and to uniquely cover the altitude regime between 50 km and 130 km above the Earth's surface. New technology efforts include GPS payload event triggering, tailored trajectories, new vehicle configuration development to expand current capabilities, and the feasibility assessment of an ultra high altitude sounding rocket vehicle. The NASA Balloon Program continues to make advancements and developments in its capabilities for support of the scientific ballooning community. The Long Duration Balloon (LDB) is capable of providing flight durations in excess of two weeks and has had many successful flights since its development. The NASA Balloon Program is currently engaged in the development of the Ultra Long Duration Balloon (ULDB), which will be capable of providing flight times up to 100-days. Additional development efforts are focusing on ultra high altitude balloons, station keeping techniques and planetary balloon technologies.

  2. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    NASA Astrophysics Data System (ADS)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  3. Montgolfiere balloon missions from Mars and Titan

    NASA Technical Reports Server (NTRS)

    Jones, Jack A.

    2005-01-01

    Montgolfieres, which are balloons that are filled with heated ambient atmospheric gas, appear promising for the exploration of Mars as well as of Saturn's moon, Titan. On Earth, Montgolfieres are also known as 'hot air balloons'. Commercial versions are typically heated by burning propane, although a number of radiant and solar-heated Montgolfieres have been flown on earth by CNES.

  4. An analysis of the deployment of a pumpkin balloon on mars

    NASA Astrophysics Data System (ADS)

    Rand, J.; Phillips, M.

    The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, which produces stress resultants determined by the volume of the system, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. The application of this technology to very large systems is currently being demonstrated by NASA's Ultra Long Duration Balloon (ULDB) Program. However, this type of balloon has certain features that may be exploited to produce a system far more robust than a comparable sphere during deployment, inflation, and operation for long periods of time. When this concept is applied to a system designed to carry two kilograms in the atmosphere of Mars, the resulting balloon is small enough to alter the construction techniques and produce an envelope which is free of tucks and folds which may cause uncontrolled stress concentrations. A technique has been demonstrated where high strength tendons may be pretensioned prior to installation along the centerline of each gore. Since this position is the shortest distance between the apex and nadir of the balloon, the tendons will automatically resist the forces caused by deployment and inflation and thereby protect the thin film gas barrier from damage. A suitable balloon has been designed for this type of mission using five-micron Mylar Type C film for the gas barrier and P O braided cables for the meridionalB load carrying members. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a ten-kilogram system suspended at the nadir of the balloon. As the

  5. Location and data collection for long stratospheric balloon flights

    NASA Astrophysics Data System (ADS)

    Malaterre, P.

    Stratospheric balloons capable of taking a 30 kg scientific payload to an altitude of 22 to 30 km for 1 month or more were developed. In-flight experiments were used to qualify the designs of a pumpkin shaped superpressure balloon and an infrared hot air balloon. Tracking of the flights (location and transmission of the parameters measured on board) was achieved using a telemetry gondola including an ARGOS beacon adapted for operation in the low temperatures encountered.

  6. On the response of superpressure balloons to displacements from equilibrium density level

    NASA Technical Reports Server (NTRS)

    Levanon, N.; Kushnir, Y.

    1976-01-01

    The response of a superpressure balloon to an initial displacement from its constant-density floating level is examined. An approximate solution is obtained to the governing vertical equation of motion for constant-density superpressure balloons. This solution is used to filter out neutrally buoyant oscillations in balloon records despite the nonlinear behavior of the balloon. The graph depicting the pressure data after deconvolution between the raw pressure data and the normalized balloon wavelet shows clearly the strong filtering-out of the neutral buoyancy oscillations.

  7. 78 FR 9785 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-12

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female ACME threaded hose connectors...., Washington, DC 20590. For service information identified in this AD, contact Lindstrand Hot Air Balloons Ltd...

  8. 77 FR 64763 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-23

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... propose to adopt a new airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female... identified in this proposed AD, contact Lindstrand Hot Air Balloons Ltd., Maesbury Road, Oswestry, Shropshire...

  9. 78 FR 18533 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-27

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... Hot Air Balloons Ltd female ACME threaded hose connectors, part numbers HS6139 and HS6144, installed... follows: * * * * * (c) Applicability This AD applies to Lindstrand Hot Air Balloons Ltd female ACME...

  10. Intrarectal pressures and balloon expulsion related to evacuation proctography.

    PubMed Central

    Halligan, S; Thomas, J; Bartram, C

    1995-01-01

    Seventy four patients with constipation were examined by standard evacuation proctography and then attempted to expel a small, non-deformable rectal balloon, connected to a pressure transducer to measure intrarectal pressure. Simultaneous imaging related the intrarectal position of the balloon to rectal deformity. Inability to expel the balloon was associated proctographically with prolonged evacuation, incomplete evacuation, reduced anal canal diameter, and acute anorectal angulation during evacuation. The presence and size of rectocoele or intussusception was unrelated to voiding of paste or balloon. An independent linear combination of pelvic floor descent and evacuation time on proctography correctly predicted maximum intrarectal pressure in 74% of cases. No patient with both prolonged evacuation and reduced pelvic floor descent on proctography could void the balloon, as maximum intrarectal pressure was reduced in this group. A prolonged evacuation time on proctography, in combination with reduced pelvic floor descent, suggests defecatory disorder may be caused by inability to raise intrarectal pressure. A diagnosis of anismus should not be made on proctography solely on the basis of incomplete/prolonged evacuation, as this may simply reflect inadequate straining. PMID:7672656

  11. Embolization of direct carotid cavernous fistulas with the novel double-balloon technique

    PubMed Central

    Niu, Yin; Li, Lin; Tang, Jun; Zhu, Gang

    2015-01-01

    Multiple endovascular management of direct carotid cavernous fistula (CCF) has been widely accepted as a treatment option. Embolization of the fistula with detachable balloons or thrombogenic coil-based occlusion has been the main choice to treat direct CCF, with good safety and efficacy. This study investigated the safety and efficacy of embolization of direct CCF with the novel double-balloon technique. A retrospective review of a prospective database on cerebral vascular disease was performed. We identified a total of five patients presenting with high-flow direct CCF. All patients were managed with transarterial embolization with the novel double-balloon technique. Three of the five patients were treated with two detachable balloons, and a completely occluded fistula with preservation of the internal carotid artery was achieved. Of the remaining two patients treated with more detachable balloons, one patient achieved a perfect outcome and the other one suffered from recurrent fistula due to balloon migration 3 weeks after embolization. During a follow-up period of 12–18 months, no symptoms reoccurred in any patient. Thus, the double-balloon treatment may be a promising method for CCF complete occlusion. This novel technique may bring more benefits in the following two cases: 1). A single inflated detachable balloon fails to completely occlude the CCF, which causing the next balloon can not pass into the fistula. 2). A giant CCF needs more balloons for fistula embolization. PMID:26586136

  12. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolizationmore » without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.« less

  13. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  14. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  15. An Overview of the NASA Sounding Rockets and Balloon Programs

    NASA Technical Reports Server (NTRS)

    Flowers, Bobby J.; Needleman, Harvey C.

    1999-01-01

    The U.S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a combined total of approximately fifty to sixty missions per year in support of the NASA scientific community. These missions are provided in support of investigations sponsored by NASA'S Offices of Space Science, Life and Microgravity Sciences & Applications, and Earth Science. The Goddard Space Flight Center has management and implementation responsibility for these programs. The NASA Sounding Rockets Program has continued to su,pport the science community by integrating their experiments into the sounding rocket payload and providing the rocket vehicle and launch operations necessary to provide the altitude/time required obtain the science objectives. The sounding rockets continue to provide a cost-effective way to make in situ observations from 50 to 1500 km in the near-earth environment and to uniquely cover the altitude regime between 50 km and 130 km above the Earth's surface, which is physically inaccessible to either balloons or satellites. A new architecture for providing this support has been introduced this year with the establishment of the NASA Sounding Rockets Contract. The Program has continued to introduce improvements into their operations and ground and flight systems. An overview of the NASA Sounding Rockets Program with special emphasis on the new support contract will be presented. The NASA Balloon Program continues to make advancements and developments in its capabilities for support of the scientific ballooning community. Long duration balloon (LDB) is a prominent aspect of the program with two campaigns scheduled for this calendar year. Two flights are scheduled in the Northern Hemisphere from Fairbanks, Alaska, in June and two flights are scheduled from McMurdo, Antarctica, in the Southern Hemisphere in December. The comprehensive balloon research and development (R&D) effort has continued with advances being made across the

  16. Overview of the TILDAE High-Altitude Balloon Mission

    NASA Astrophysics Data System (ADS)

    Godbole, N. H.; Maruca, B.; Marino, R.; Sundkvist, D. J.; Constantin, S.; Zimmerman, H.; Carbone, V.

    2016-12-01

    Though the presence of intermittent turbulence in the stratosphere has been well established, much remains unknown about it. In situ observations of this phenomenon, which have provided the greatest detail of it, have typically been achieved via sounding balloons (i.e., small balloons which burst at peak altitude) carrying constant-temperature "hot wire" anemometers (CTAs). The Turbulence and Intermittency Long-Duration Atmospheric Experiment (TILDAE) was developed to test a new paradigm for stratospheric observations. Rather than flying on a sounding balloon, TILDAE was incorporated as an "add-on" experiment to the payload of a NASA long-duration balloon mission that launched in January, 2016 from McMurdo Station, Antarctica. Furthermore, TILDAE's key instrument was a sonic anemometer, which (relative to a CTA) provides better-calibrated measurements of wind velocity and more-robust separation of velocity components. This presentation focuses on the technical details of TILDAE's instrumentation and the performance thereof during its flight. Potential design improvements for future flights are also discussed.

  17. Balloon-based interferometric techniques

    NASA Technical Reports Server (NTRS)

    Rees, David

    1985-01-01

    A balloon-borne triple-etalon Fabry-Perot Interferometer, observing the Doppler shifts of absorption lines caused by molecular oxygen and water vapor in the far red/near infrared spectrum of backscattered sunlight, has been used to evaluate a passive spaceborne remote sensing technique for measuring winds in the troposphere and stratosphere. There have been two successful high altitude balloon flights of the prototype UCL instrument from the National Scientific Balloon Facility at Palestine, TE (May 80, Oct. 83). The results from these flights have demonstrated that an interferometer with adequate resolution, stability and sensitivity can be built. The wind data are of comparable quality to those obtained from operational techniques (balloon and rocket sonde, cloud-top drift analysis, and from the gradient wind analysis of satellite radiance measurements). However, the interferometric data can provide a regular global grid, over a height range from 5 to 50 km in regions of clear air. Between the middle troposphere (5 km) and the upper stratosphere (40 to 50 km), an optimized instrument can make wind measurements over the daylit hemisphere with an accuracy of about 3 to 5 m/sec (2 sigma). It is possible to obtain full height profiles between altitudes of 5 and 50 km, with 4 km height resolution, and a spatial resolution of about 200 km, along the orbit track. Below an altitude of about 10 km, Fraunhofer lines of solar origin are possible targets of the Doppler wind analysis. Above an altitude of 50 km, the weakness of the backscattered solar spectrum (decreasing air density) is coupled with the low absorption crosssection of all atmospheric species in the spectral region up to 800 nm (where imaging photon detectors can be used), causing the along-the-track resolution (or error) to increase beyond values useful for operational purposes. Within the region of optimum performance (5 to 50 km), however, the technique is a valuable potential complement to existing wind

  18. Effect of repeated injection and continuous infusion of omeprazole and ranitidine on intragastric pH over 72 hours.

    PubMed

    Netzer, P; Gaia, C; Sandoz, M; Huluk, T; Gut, A; Halter, F; Hüsler, J; Inauen, W

    1999-02-01

    In healthy subjects and patients with bleeding peptic ulcers, ranitidine and omeprazole, given parenterally, achieve high intragastric pH values on the first day of therapy. However, data on the antisecretory effect beyond the first 24 h is scanty. In addition, the superiority of either infusion or injection of omeprazole remains unproven. Thus, we have compared the antisecretory effect of high dose omeprazole and ranitidine infusion and injection over the critical first 72 h. A total of 34 healthy volunteers were randomized into a double-blind crossover 72 h intragastric pH-metry study (data compared: median pH, percentage of time with pH >4 and pH >6). Omeprazole-infusion: initial bolus of 80 mg + 8 mg/h; omeprazole-injection: initial bolus of 80 mg + 40 mg/6 h; Ranitidine-infusion: initial bolus of 50 mg + 0.25 mg/kg/h; ranitidine-injection: 100 mg/6 h. Omeprazole-infusion versus ranitidine-infusion: on day 1: median pH 6.1 vs 5.1 (p = 0.01) and 95% vs 70% was pH >4 (p < 0.01); on day 2: median pH 6.2 vs 3.2 (p < 0.01); and 100% vs 38% was pH >4 (p < 0.01); on day 3: median pH 6.3 vs 2.7 (p < 0.01); 100% vs 26% was pH >4 (p < 0.01). Injections of both drugs were significantly less effective than the infusions on day 1. Thereafter, omeprazole injection was almost as effective as omeprazole infusion, whereas ranitidine injection and infusion were equally effective. Our study shows, for the first time, that omeprazole infusion was significantly superior to all other regimens by having a high median pH >6 on each day. The tolerance effect of ranitidine, however, led to a rapid loss of antisecretory activity on days 2 and 3, rendering it inappropriate for situations in which high intragastric pH-levels appear to be essential.

  19. Evaluation of balloon trajectory forecast routines for GAINS

    NASA Astrophysics Data System (ADS)

    Collander, R.; Girz, C.

    The Global Air-ocean IN-situ System (GAINS) is a global observing system designed to augment current environmental observing and monitoring networks. GAINS is a network of long-duration, stratospheric platforms that carry onboard sensors and hundreds of dropsondes to acquire meteorological, air chemistry, and climate data over oceans and in remote land regions of the globe. Although GAINS platforms will include balloons and Remotely Operated Aircraft (ROA), the scope of this paper is limited to balloon-based platforms. A primary goal of GAINS balloon test flights is post-flight recovery of the balloon shell and payload, which requires information on the expected flight path and landing site prior to launch. Software has been developed for the prediction of the balloon trajectory and landing site, with separate versions written to generate predictions based upon rawinsonde data and model output. Balloon positions are calculated in 1-min increments based on wind data from the closest rawinsonde site or model grid point, given a known launch point, ascent and descent rate and flight duration. For short flights (< 6h), rawinsonde winds interpolated to 10-mb levels are used for trajectory calculations. Predictions for flight durations of 6 to 48h are based upon the initialization and 3 h forecast wind fields from NOAA's global aviation- (AVN) and Rapid Update Cycle (RUC) models. Given a limited number of actual balloon launches, trajectories computed from a chronological series of hourly RUC initializations are used as the baseline for comparison purposes. These baseline trajectories are compared to trajectory predictions from the rawinsonde and model-based versions on a monthly and seasonal basis over a 1-year period (January 1 - December 31, 2001) for flight durations of 3h, 6h and 48h. Predicted trajectories diverge from the baseline path, with the divergence increasing with increasing time. We examine the zonal, meridional and net magnitudes of these deviations, and

  20. Near Space Lab-Rat Experimentation using Stratospheric Balloon

    NASA Astrophysics Data System (ADS)

    Buduru, Suneel Kumar; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Trivedi, Dharmesh; Devarajan, Anand; Pandit Manikrao Kulkarni, MR..; Ojha, Devendra; Korra, Sakram; Neerudu, Nagendra; Seng, Lim; Godi, Stalin Peter

    2016-07-01

    First ever balloon borne lab-rat experiment up to near space stratospheric altitude levels carried out at TIFR Balloon Facility, Hydeabad using zero pressure balloons for the purpose of validating the life support system. A series of two balloon experiments conducted under joint collaboration with IN.Genius, Singapore in the year 2015. In these experiments, three lab-rats sent to stratosphere in a pressurized capsule designed to reach an altitude of 30 km by keeping constant pressure, temperature and maintained at a precise rate of oxygen supply inside the capsule. The first experiment conducted on 1 ^{st} February, 2015 with a total suspended weight of 225 kg. During the balloon ascent stage at 18 km altitude, sensors inside the capsule reported drastic drop in internal pressure while oxygen and temperatures maintained at correct levels resulted in premature fligt termination at 20.1 km. All the three lab-rats recovered without life due to the collapse of their lungs caused by the depressurization inside the capsule. The second experiment conducted on 14th March, 2015 using a newly developed capsule with rectification of depressurization fault by using improved sealing gaskets and hermitically sealed connectors for sending lab-rats again to stratosphere comprising a total suspended load of 122.3 kg. The balloon flight was terminated after reaching 29.5 km in 110 minutes and succesfully recovered all the three lab-rats alive. This paper focuses on lessons learnt of the development of the life support system as an integral pressurized vessel, flight control instrumentation, flight simulation tests using thermo-vaccum chamber with pre-flight operations.

  1. Ballooning Interest in Science.

    ERIC Educational Resources Information Center

    Kim, Hy

    1992-01-01

    Presents an activity in which students construct model hot air balloons to introduce the concepts of convection current, the principles of Charles' gas law, and three-dimensional geometric shapes. Provides construction and launching instructions. (MDH)

  2. Modelling hot air balloons

    NASA Astrophysics Data System (ADS)

    Brimicombe, N. W.

    1991-07-01

    Hot air balloons can be modelled in a number of different ways. The most satisfactory, but least useful model is at a microscopic level. Macroscopic models are easier to use but can be very misleading.

  3. The Descending Helium Balloon

    ERIC Educational Resources Information Center

    Helseth, Lars Egil

    2014-01-01

    I describe a simple and fascinating experiment wherein helium leaks out of a rubber balloon, thereby causing it to descend. An estimate of the volumetric leakage rate is made by measuring its rate of descent.

  4. Ignition of Hydrogen Balloons by Model-Rocket-Engine Igniters.

    ERIC Educational Resources Information Center

    Hartman, Nicholas T.

    2003-01-01

    Describes an alternative method for exploding hydrogen balloons as a classroom demonstration. Uses the method of igniting the balloons via an electronic match. Includes necessary materials to conduct the demonstration and discusses potential hazards. (SOE)

  5. Balloon platform for extended-life astronomy research

    NASA Technical Reports Server (NTRS)

    Ostwald, L. T.

    1974-01-01

    A configuration has been developed for a long-life balloon platform to carry pointing telescopes weighing as much as 80 pounds (36 kg) to point at selected celestial targets. A platform of this configuration weighs about 375 pounds (170 kg) gross and can be suspended from a high altitude super pressure balloon for a lifetime of several months. The balloon platform contains a solar array and storage batteries for electrical power, up and down link communications equipment, and navigational and attitude control systems for orienting the scientific instrument. A biaxial controller maintains the telescope attitude in response to look-angle data stored in an on-board computer memory which is updated periodically by ground command. Gimbal angles are computed by using location data derived by an on-board navigational receiver.

  6. Hot-air balloon tours: crash epidemiology in the United States, 2000-2011.

    PubMed

    Ballard, Sarah-Blythe; Beaty, Leland P; Baker, Susan P

    2013-11-01

    Hot-air balloon tours are FAR Part 91-governed balloon rides conducted for compensation or hire. Part 91, General Aviation, in general involves the least strict federal regulations and accounts for the majority of aviation crashes and fatalities. National Transportation Safety Board reports of hot-air balloon tour crashes in the United States from 2000 through 2011 were read and analyzed. During the 12-yr period, 78 hot-air balloon tours crashed, involving 518 occupants. There were 91 serious injuries and 5 fatalities; 83% of crashes resulted in one or more serious or fatal outcomes. Of the serious injuries characterized, 56% were lower extremity fractures. Most crashes (81%) occurred during landing; 65% involved hard landings. Fixed object collisions contributed to 50% of serious injuries and all 5 fatalities. During landing sequences, gondola dragging, tipping, bouncing, and occupant ejection were associated with poor outcomes. Of the crashes resulting in serious or fatal outcomes, 20% of balloons were significantly damaged or destroyed. The incidence of morbidity and mortality is high among hot-air balloon tour crashes, and the proportion of balloon crashes attributed to paid rides appears to have increased over time. In addition to examining the role of restraint systems, personal protective equipment, and power line emergency procedures in ballooning, injury prevention efforts should target factors such hard landings, object strikes, gondola instability, and occupant ejections, which are associated with balloon injuries and deaths. Crash outcomes may also improve with vehicle engineering that enables balloons themselves to absorb impact forces.

  7. Hot-Air Balloon Tours: Crash Epidemiology in the United States, 2000-2011

    PubMed Central

    Ballard, Sarah-Blythe; Beaty, Leland P.; Baker, Susan P.

    2016-01-01

    Introduction Hot-air balloon tours are FAR Part 91-governed balloon rides conducted for compensation or hire. Part 91, General Aviation, in general involves the least strict federal regulations and accounts for the majority of aviation crashes and fatalities. Methods National Transportation Safety Board reports of hot-air balloon tour crashes in the United States from 2000 through 2011 were read and analyzed. Results During the 12-yr period, 78 hot-air balloon tours crashed, involving 518 occupants. There were 91 serious injuries and 5 fatalities; 83% of crashes resulted in one or more serious or fatal outcomes. Of the serious injuries characterized, 56% were lower extremity fractures. Most crashes (81%) occurred during landing; 65% involved hard landings. Fixed object collisions contributed to 50% of serious injuries and all 5 fatalities. During landing sequences, gondola dragging, tipping, bouncing, and occupant ejection were associated with poor outcomes. Of the crashes resulting in serious or fatal outcomes, 20% of balloons were significantly damaged or destroyed. Discussion The incidence of morbidity and mortality is high among hot-air balloon tour crashes, and the proportion of balloon crashes attributed to paid rides appears to have increased over time. In addition to examining the role of restraint systems, personal protective equipment, and power line emergency procedures in ballooning, injury prevention efforts should target factors such hard landings, object strikes, gondola instability, and occupant ejections, which are associated with balloon injuries and deaths. Crash outcomes may also improve with vehicle engineering that enables balloons themselves to absorb impact forces. PMID:24279231

  8. Indwelling esophageal balloon catheter for benign esophageal stenosis in infants and children.

    PubMed

    van der Zee, David; Hulsker, Caroline

    2014-04-01

    Balloon dilatation of benign esophageal strictures is an established mode of therapy in adults and children. There remains a group of patients with refractory stenosis despite dilatation at regular intervals. An indwelling balloon catheter may offer an alternative. This is a retrospective study of 19 children who underwent esophagoscopy between 2004 and 2012 with placement of an indwelling balloon catheter for refractory esophageal stenosis. Total number of endoscopies, number of endoscopies with indwelling balloon catheter, as well as complications, reoperations, and mortality due to use of the balloon catheter were studied. Patient age ranged from 4 weeks to 15 years. The indwelling balloon catheter was used to treat refractory stenosis after corrective surgery of long gap esophageal atresia (n = 5), esophageal atresia with distal fistula (n = 2), refractory esophageal stenosis due to caustic esophageal burns (n = 7), reflux (n = 2), and stenosis of unknown cause (n = 3). With the indwelling balloon catheter in place, the mean number of endoscopies equalled four. Complications were restenosis after a symptom-free period for which a new indwelling balloon catheter was necessary (n = 3). Two others needed two to five additional dilations: balloon leakage requiring replacement (n = 7 in 5 patients), sputum retention (n = 1), and dislodgement (n = 5 in 4 patients). More importantly, there was no mortality or the need for any patient to undergo a surgical resection. The indwelling balloon catheter is safe to use and can be used by parents at home. More importantly it obviates the need for rethoracotomy/-scopy or esophageal replacement.

  9. Combined analysis of three crossover clinical pharmacology studies of effects of rabeprazole and esomeprazole on 24-h intragastric pH in healthy volunteers.

    PubMed

    Norris, V; Baisley, K; Dunn, K; Warrington, S; Morocutti, A

    2007-02-15

    To compare antisecretory effects of rabeprazole and esomeprazole after single and repeat dosing in Helicobacter pylori-negative healthy volunteers. Results were pooled from three smaller, open, crossover, randomized studies to obtain data from 80 subjects. The studies compared: (a) 5 days' dosing of 20 mg rabeprazole and esomeprazole (n = 24); (b) single doses of rabeprazole 20 mg and esomeprazole 40 mg (n = 27) and (c) 5 days' dosing of rabeprazole 10 mg and esomeprazole 20 mg (n = 29). Washout periods were > or =14 days. Intragastric pH was recorded continuously for 24 h on days 0, 1 and 5. Single doses of rabeprazole 20 mg maintained 24-h intragastric pH >4 for longer than esomeprazole 20 mg (45% vs. 32%; P < 0.001); rabeprazole 20 mg and esomeprazole 40 mg were equivalent in their effects. After 5 days' dosing, rabeprazole 20 mg maintained pH >4 for longer than esomeprazole 20 mg (62% vs. 56%; P = 0.046); the reverse was true for esomeprazole 20 mg vs. rabeprazole 10 mg (56% vs. 48%; P = 0.035). In general, intragastric pH AUC during 0-5 h after dosing was higher after esomeprazole than rabeprazole, whereas the reverse was true during the night. The order of effects on 24-h pH was: rabeprazole 10 mg < or = esomeprazole 20 mg < rabeprazole 20 mg = esomeprazole 40 mg. Esomeprazole acts faster, whereas rabeprazole's effect lasts longer.

  10. Cutting balloon and high-pressure balloon dilation for palliative treatment of congenital double-chambered right ventricle and primary infundibular stenosis in a Golden retriever dog.

    PubMed

    Schober, Karsten E; Rhinehart, Jaylyn; Kohnken, Rebecca; Bonagura, John D

    2017-12-01

    Combined cutting balloon and high-pressure balloon dilation was performed in a dog with a double-chambered right ventricle and severe infundibular stenosis of the right ventricular outflow tract. The peak systolic pressure gradient across the stenosis decreased by 65% after dilation (from 187 mmHg before to 66 mmHg after) affirming the intervention as successful. However, early re-stenosis occurred within 3 months leading to exercise intolerance, exercise-induced syncope, and right-sided congestive heart failure. Cutting balloon followed by high-pressure balloon dilation provided temporary but not long-term relief of right ventricular obstruction in this dog. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Iridium: Global OTH data communications for high altitude scientific ballooning

    NASA Astrophysics Data System (ADS)

    Denney, A.

    While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several

  12. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    PubMed

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  13. Multicenter comparison of double-balloon enteroscopy and spiral enteroscopy.

    PubMed

    Rahmi, Gabriel; Samaha, Elia; Vahedi, Kouroche; Ponchon, Thierry; Fumex, Fabien; Filoche, Bernard; Gay, Gerard; Delvaux, Michel; Lorenceau-Savale, Camille; Malamut, Georgia; Canard, Jean-Marc; Chatellier, Gilles; Cellier, Christophe

    2013-06-01

    Spiral enteroscopy is a novel technique for small bowel exploration. The aim of this study is to compare double-balloon and spiral enteroscopy in patients with suspected small bowel lesions. Patients with suspected small bowel lesion diagnosed by capsule endoscopy were prospectively included between September 2009 and December 2010 in five tertiary-care academic medical centers. After capsule endoscopy, 191 double-balloon enteroscopy and 50 spiral enteroscopies were performed. Indications were obscure gastrointestinal bleeding in 194 (80%) of cases. Lesions detected by capsule endoscopy were mainly angioectasia. Double-balloon and spiral enteroscopy resulted in finding one or more lesions in 70% and 75% of cases, respectively. The mean diagnosis procedure time and the average small bowel explored length during double-balloon and spiral enteroscopy were, respectively, 60 min (45-80) and 55 min (45-80) (P=0.74), and 200 cm (150-300) and 220 cm (200-300) (P=0.13). Treatment during double-balloon and spiral enteroscopy was possible in 66% and 70% of cases, respectively. There was no significant major procedure-related complication. Spiral enteroscopy appears as safe as double-balloon enteroscopy for small bowel exploration with a similar diagnostic and therapeutic yield. Comparison between the two procedures in terms of duration and length of small bowel explored is slightly in favor of spiral enteroscopy but not significantly. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  14. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    A view looking over the payload – the instruments that fly under a balloon – while the BARREL balloon inflates. The orange parachute lies on the ground in front of the payload, while most of the balloon length can be seen stretched along the ground toward the part being inflated. Credit: NASA/Goddard/BARREL Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy.NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission.Follow us on TwitterLike us on FacebookFind us on Instagram

  15. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2017-12-08

    BARREL researchers get ready to release the top part of the balloon, called the bubble, as it fills with enough helium to support itself. Only the top part of the balloon is inflated before launch since the helium expands as the balloon ascends. Credit: NASA/Goddard/BARREL/Nicky Knox Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  16. Usefulness of cutting balloon angioplasty for the treatment of congenital heart defects.

    PubMed

    Kusa, Jacek; Mazurak, Magdalena; Skierska, Agnieszka; Szydlowski, Leslaw; Czesniewicz, Pawel; Manka, Lukasz

    2018-01-01

    Patients with complex congenital heart defects may have different hemodynamic prob-lems which require a variety of interventional procedures including angioplasty which involves using high-pressure balloons. After failure of conventional balloon angioplasty, cutting balloon angioplasty is the next treatment option available. The purpose of this study was to evaluate the safety and efficacy of cutting balloon angioplasty in children with different types of congenital heart defects. Cutting balloon angioplasty was performed in 28 children with different congenital heart defects. The indication for cutting balloon angioplasty was: pulmonary artery stenosis in 17 patients, creating or dilatation of interatrial communication in 10 patients, and stenosis of left subclavian artery in 1 patient. In the pulmonary arteries group there was a significant decrease in systolic blood pressure (SBP) in the proximal part of the artery from the average 74.33 ± 20.4 mm Hg to 55 ± 16.7 mm Hg (p < 0.001). Distal to the stenosis there was an increase in SBP from 19.8 ± 3.82 mm Hg to 30.3 ± ± 13.3 mm Hg (p = 0.04). This result remained constant in the follow-up. In atrial septal defect/fenestra-tion group, cutting balloon angioplasty was performed after an unsuccessful classic Rashkind procedure. After cutting balloon angioplasty there was a significant widening of the interatrial communication. Cutting balloon angioplasty is a feasible and effective treatment option in different con-genital heart defects.

  17. Blood pressure normalization post-jugular venous balloon angioplasty.

    PubMed

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  18. A buoyant tornado-probe concept incorporating an inverted lifting device. [and balloon combination

    NASA Technical Reports Server (NTRS)

    Grant, F. C.

    1973-01-01

    Addition of an inverted lifting device to a simple balloon probe is shown to make possible low-altitude entry to tornado cores with easier launch conditions than for the simple balloon probe. Balloon-lifter combinations are particularly suitable for penetration of tornadoes with average to strong circulation, but tornadoes of less than average circulation which are inaccessible to simple balloon probes become accessible. The increased launch radius which is needed for access to tornadoes over a wide range of circulation results in entry times of about 3 minutes. For a simple balloon probe the uninflated balloon must be first dropped on, or near, the track of the tornado from a safe distance. The increase in typical launch radius from about 0.75 kilometer to slightly over 1.0 kilometer with a balloon-lifter combination suggests that a direct air launch may be feasible.

  19. Space and Earth Observations from Stratospheric Balloons

    NASA Astrophysics Data System (ADS)

    Peterzen, Steven; Ubertini, Pietro; Masi, Silvia; Ibba, Roberto; Ivano, Musso; Cardillo, Andrea; Romeo, Giovanni; Dragøy, Petter; Spoto, Domenico

    Stratospheric balloons are rapidly becoming the vehicle of choice for near space investigations and earth observations by a variety of science disciplines. With the ever increasing research into climatic change, instruments suspended from stratospheric balloons offer the science team a unique, stable and reusable platform that can circle the Earth in the polar region or equatorial zone for thirty days or more. The Italian Space Agency (ASI) in collaboration with Andoya Rocket Range (Andenes, Norway) has opened access in the far northern latitudes above 78o N from Longyearbyen, Svalbard. In 2006 the first Italian UltraLite Long Duration Balloon was launched from Baia Terra Nova, Mario Zuchelli station in Antarctica and now ASI is setting up for the their first equatorial stratospheric launch from their satellite receiving station and rocket launch site in Malindi, Kenya. For the equatorial missions we have analysed the statistical properties of trajectories considering the biennal oscillation and the seasonal effects of the stratospheric winds. Maintaining these launch sites offer the science community 3 point world coverage for heavy lift balloons as well as the rapidly deployed Ultralight payloads and TM system ASI developed to use for test platforms, micro experiments, as well as a comprehensive student pilot program

  20. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    PubMed

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  1. High Altitude Ozone Research Balloon

    NASA Technical Reports Server (NTRS)

    Cauthen, Timothy A.; Daniel, Leslie A.; Herrick, Sally C.; Rock, Stacey G.; Varias, Michael A.

    1990-01-01

    In order to create a mission model of the high altitude ozone research balloon (HAORB) several options for flight preparation, altitude control, flight termination, and payload recovery were considered. After the optimal launch date and location for two separate HAORB flights were calculated, a method for reducing the heat transfer from solar and infrared radiation was designed and analytically tested. This provided the most important advantage of the HAORB over conventional balloons, i.e., its improved flight duration. Comparisons of different parachute configurations were made, and a design best suited for the HAORB's needs was determined to provide for payload recovery after flight termination. In an effort to avoid possible payload damage, a landing system was also developed.

  2. Some special sub-systems for stratospheric balloon flights in India

    NASA Astrophysics Data System (ADS)

    Damle, S. V.; Gokhale, G. S.; Kundapurkar, R. U.

    During last few years several new sub-systems for balloon were developed and are being regularly used in the balloon flights. Some of these sub-systems are i) positive monitor for magnetic ballast release using an opto-electronic device ii) one-way pressure switch to terminate flight for runaway balloon iii) in-flight payload reel down system for atmospheric science experiment. The design, usage and performance of these and other sub-systems will be presented.

  3. Hot air balloons fill gap in atmospheric and sensing platforms

    NASA Astrophysics Data System (ADS)

    Watson, Steven M.; Price, Russ

    Eric Edgerton was having a problem he could not solve: how to noninvasively collect in situ incinerator plume data. So he called in the Air Force and learned about its Atmospheric and Sensor Test Platform program; its platform is a manned hot air balloon. Many investigators are discovering the advantages of hot air balloons as stable, inexpensive platforms for performing in situ atmospheric measurements. Some are also using remote sensing capabilities on the balloon platforms.

  4. Launching a Tethered Balloon in the Artic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2017-08-14

    Sandia atmospheric scientist Dari Dexheimer regularly flies tethered balloons out of Sandia’s dedicated Arctic airspace on Oliktok Point, the northernmost point of Alaska’s Prudhoe Bay. These 13-foot-tall balloons carry distributed temperature sensors to collect Arctic atmospheric temperature profiles, or the temperature of the air at different heights above the ground, among other atmospheric sensors. The data Sandia collects is critical for understanding Arctic clouds to inform global climate models.

  5. Catching Comet's Particles in the Earth's Atmosphere by Using Balloons

    NASA Astrophysics Data System (ADS)

    Potashko, Oleksandr; Viso, Michel

    The project is intended to catch cometary particles in the atmosphere by using balloons. The investigation is based upon knowledge that the Earth crosses the comet’s tails during the year. One can catch these particles at different altitudes in the atmosphere. So, we will be able to gradually advance in the ability to launch balloons from low to high altitudes and try to catch particles from different comet tails. The maximum altitude that we have to reach is 40 km. Both methods - distance observation and cometary samples from mission Stardust testify to the presence of organic components in comet’s particles. It would be useful to know more details about this organic matter for astrobiology; besides, the factor poses danger to the Earth. Moreover, it is important to prove that it is possible to get fundamental scientific results at low cost. In the last 5 years launching balloons has become popular and this movement looks like hackers’ one - as most of them occur without launch permission to airspace. The popularity of ballooning is connected with low cost of balloon, GPS unit, video recording unit. If you use iPhone, you have a light solution with GPS, video, picture and control function in one unit. The price of balloon itself begins from $50; it depends on maximum altitude, payload weight and material. Many university teams realized balloon launching and reached even stratosphere at an altitude of 33 km. But most of them take only video and picture. Meanwhile, it is possible to carry out scientific experiments by ballooning, for example to collect comet particles. There is rich experience at the moment of the use of mineral, chemical and isotopic analysis techniques and data of the comet’s dust after successful landing of StarDust capsule with samples in 2006. Besides, we may use absolutely perfect material to catch particles in the atmosphere, which was used by cosmic missions such as Stardust and Japanese Hayabusa. As to balloon launches, we could use

  6. European Venus Explorer: An in-situ mission to Venus using a balloon platform

    NASA Astrophysics Data System (ADS)

    Chassefière, E.; Korablev, O.; Imamura, T.; Baines, K. H.; Wilson, C. F.; Titov, D. V.; Aplin, K. L.; Balint, T.; Blamont, J. E.; Cochrane, C. G.; Ferencz, Cs.; Ferri, F.; Gerasimov, M.; Leitner, J. J.; Lopez-Moreno, J.; Marty, B.; Martynov, M.; Pogrebenko, S. V.; Rodin, A.; Whiteway, J. A.; Zasova, L. V.; the EVE Team

    2009-07-01

    Planetary balloons have a long history already. A small super-pressure balloon was flown in the atmosphere of Venus in the eighties by the Russian-French VEGA mission. For this mission, CNES developed and fully tested a 9 m diameter super-pressure balloon, but finally replaced it by a smaller one due to mass constraints (when it was decided to send Vega to Halley's Comet). Furthermore, several kinds of balloons have been proposed for planetary exploration [Blamont, J., in: Maran, S.P. (Ed.), The Astronomy and Astrophysics Encyclopedia. Cambridge University Press, p. 494, 1991]. A Mars balloon has been studied for the Mars-94 Russian-French mission, which was finally cancelled. Mars and Venus balloons have also been studied and ground tested at JPL, and a low atmosphere Venus balloon is presently under development at JAXA (the Japanese Space Agency). Balloons have been identified as a key element in an ongoing Flagship class mission study at NASA, with an assumed launch date between 2020 and 2025. Recently, it was proposed by a group of scientists, under European leadership, to use a balloon to characterize - by in-situ measurements - the evolution, composition and dynamics of the Venus atmosphere. This balloon is part of a mission called EVE (European Venus Explorer), which has been proposed in response to the ESA AO for the first slice of the Cosmic Vision program by a wide international consortium including Europe, Russia, Japan and USA. The EVE architecture consists of one balloon platform floating at an altitude of 50-60 km, one short lived probe provided by Russia, and an orbiter with a polar orbit to relay data from the balloon and probe, and to perform remote sensing science observations. The balloon type preferred for scientific goals is one, which would oscillate in altitude through the cloud deck. To achieve this flight profile, the balloon envelope would contain a phase change fluid. While this proposal was not selected for the first slice of Cosmic

  7. Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors

    NASA Astrophysics Data System (ADS)

    Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.; Cutts, James A.; Garcia, Raphael F.; Mimoun, David; Cadu, Alexandre; Sournac, Anthony; Jackson, Jennifer M.; Lai, Voon Hui; Bowman, Daniel C.

    2018-04-01

    We conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hot air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.

  8. Measurement of gastric emptying by intragastric gamma scintigraphy.

    PubMed

    Malbert, C H; Mathis, C; Bobillier, E; Laplace, J P; Horowitz, M

    1997-09-01

    Gastric emptying is usually measured in animals and humans by dilution/sampling or external scintigraphy. These methods are either time consuming or require expensive equipment. The capacity of a miniature gamma counter positioned in the stomach to measure emptying of liquid and solid meals was evaluated. In eight conscious pigs fitted with gastric and duodenal cannulae, gastric emptying of saline (500 mL), dextrose (20%, 500 mL), porridge (300 g) and scrambled eggs (300 g), all labelled with 3.5 MBq 99mTC, was evaluated. When positioned in the antrum the probe was unable to quantify gastric emptying. In contrast, measurements of the fractional emptying of saline over 4-min periods by the probe positioned in the corpus and quantification of radioactivity in the duodenal effluent correlated closely (r = 0.88, P < 0.05). Gastric emptying (50% emptying time) of saline and both solid meals measured by the probe was not significantly different from quantification of the duodenal effluent volume. No difference was observed also for the dextrose meal but only while gastric acid secretion was suppressed by omeprazole. We conclude that an intragastric gamma counter permits measurement of gastric emptying of homogeneous meals provided meal stimulation of gastric secretion was not extensive. This was possible probably by monitoring emptying from the proximal stomach.

  9. Evolution of NASA Scientific Ballooning and Particle Astrophysics Research

    NASA Astrophysics Data System (ADS)

    Jones, William Vernon

    2017-01-01

    Particle astrophysics research has a history in ballooning that spans over 100 years, ever since Victor Hess discovered cosmic rays on a manned balloon in 1912. The NASA Particle Astrophysics Program currently covers the origin, acceleration and transport of Galactic cosmic rays, plus the Nature of Dark Matter and Ultrahigh Energy Neutrinos. Progress in each of these topics has come from sophisticated instrumentation flown on Long Duration Balloon (LDB) flights around Antarctica for more than two decades. Super Pressure Balloons (SPB) and International Space Station (ISS) platforms are emerging opportunities that promise major steps forward for these and other objectives. NASA has continued development and qualification flights leading to SPB flights capable of supporting 1000 kg science instruments to 33 km for upwards of hundred day missions, with plans for increasing the altitude to 38 km. This goal is even more important now, in view of the Astro2010 Decadal Study recommendation that NASA should support Ultra-Long Duration Balloon (ULDB) flight development for studies of particle astrophysics, cosmology and indirect detection of dark matter. The mid-latitude test flight of an 18.8 MCF SPB launched from Wanaka, NZ in 2015 achieved 32 days of nearly constant altitude exposure, and an identical SPB launched from Wanaka in 2016 with a science payload flew for 46 days. Scientific ballooning as a vital infrastructure component for cosmic ray and general astrophysics investigations, including training for young scientists, graduate and undergraduate students, leading up to the 2020 Decadal Study and beyond, will be presented and discussed.

  10. Transarterial Balloon-assisted Onyx Embolization of Intracranial Arteriovenous Malformations Using a Dual-lumen Balloon Microcatheter: Two Case Reports.

    PubMed

    Kim, Sang Heum; Kim, Tae Gon; Kong, Min Ho

    2017-09-01

    The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge.

  11. Transarterial Balloon-assisted Onyx Embolization of Intracranial Arteriovenous Malformations Using a Dual-lumen Balloon Microcatheter: Two Case Reports

    PubMed Central

    Kim, Sang Heum; Kong, Min Ho

    2017-01-01

    The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge. PMID:29159158

  12. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    The BARREL cargo on its four-hour journey from the supply ship to the research station. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science

  13. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    The BARREL team at the SANAE IV research station celebrates their final launch in the Antarctica sun. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors

  14. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    An emperor penguin waddles away on Christmas morning in Antarctica. On Christmas day, the BARREL team visited a penguin colony. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through

  15. Intragastric inulin as a measure of mucosal damage caused by aspirin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wittmers, L.E. Jr.; Anderson, L.A.; Fall, M.M.

    In an attempt to find a method of gastric mucosal damage assessment that yields consistent results, the experiments presented here employed the measurement of the movement of inulin out of the gastric contents into the stomach wall and vascular compartment as an estimate of mucosal damage. Anesthetized male Sprague-Dawley rats were functionally nephrectomized and were administered a control or test solution containing 3H-inulin. The test solutions contained one of three doses of aspirin. Blood samples were taken at 15-min intervals over a 90-min exposure period. The stomach was removed from the animal and full-thickness tissue samples taken for measurement ofmore » 3H-inulin content. When the gastric mucosa was exposed to the test agents, there was a significantly greater accumulation of inulin in the body and antrum as well as in the plasma when compared to controls. We conclude that intragastric inulin can be employed to estimate gastric mucosal damage.« less

  16. Trace gas measurements from tethered balloon platforms

    NASA Technical Reports Server (NTRS)

    Bandy, Alan R.; Bandy, Terese L.; Youngbluth, Otto; Owens, Thomas L.

    1987-01-01

    Instrumentation and chemical sampling and analysis procedures are described for making measurements of atmospheric carbon disulfide in the concentration range 1-1000 pptv from tethered balloon platforms. Results of a study on the CS2 composition of air downward of a saltwater marsh are reported. A method for obtaining the necessary data for solving the budget equations for surface fluxes, chemical formation rates and chemical destruction rates using data acquired from tethered balloon platforms is presented.

  17. Recent results in the NASA research balloon program

    NASA Technical Reports Server (NTRS)

    Jones, W. Vernon

    1989-01-01

    The NASA Balloon Program has progressed from a total hiatus in the fall of 1985 to an unprecedented flight success rate in the fall of 1988. Using heavy-lift balloons being regularly supplied by two manufacturers, the program has provided a timely response for investigations of Supernova 1987A from Australia, low energy cosmic ray investigations from Canada during periods of near-solar-minimum, and routine domestic turnaround flights for a variety of investigations. Recent re-evaluation of balloon flight-safety have resulted in severe constraints on flights launched from the Palestine, Texas facility. The future program must rely heavily on the use of remote launch sites to meet the growing requirements for more frequent and longer duration flights being planned for the next 3 - 5 years.

  18. Effects of Intragastric Administration of Tryptophan on the Blood Glucose Response to a Nutrient Drink and Energy Intake, in Lean and Obese Men.

    PubMed

    Ullrich, Sina S; Fitzgerald, Penelope C E; Giesbertz, Pieter; Steinert, Robert E; Horowitz, Michael; Feinle-Bisset, Christine

    2018-04-08

    Tryptophan stimulates plasma cholecystokinin and pyloric pressures, both of which slow gastric emptying. Gastric emptying regulates postprandial blood glucose. Tryptophan has been reported to decrease energy intake. We investigated the effects of intragastric tryptophan on the glycaemic response to, and gastric emptying of, a mixed-nutrient drink, and subsequent energy intake. Lean and obese participants ( n = 16 each) received intragastric infusions of 1.5 g ("Trp-1.5g") or 3.0 g ("Trp-3.0g") tryptophan, or control, and 15 min later consumed a mixed-nutrient drink (56 g carbohydrates). Gastric emptying ( 13 C-acetate breath-test), blood glucose, plasma C-peptide, glucagon, cholecystokinin and tryptophan concentrations were measured ( t = 0-60 min). Energy intake was assessed between t = 60-90 min. In lean individuals, Trp-3.0g, but not Trp-1.5g, slowed gastric emptying, reduced C-peptide AUC and increased glucagon AUC (all P < 0.05), but did not significantly decrease the blood glucose response to the drink, stimulate cholecystokinin or reduce mean energy intake, compared with control. In obese individuals, Trp-3.0g, but not Trp-1.5g, tended to slow gastric emptying ( P = 0.091), did not affect C-peptide AUC , increased glucagon AUC ( P < 0.001) and lowered blood glucose at t = 30 min ( P < 0.05), and did not affect cholecystokinin or mean energy intake. In obese individuals, intragastrically administered tryptophan may reduce postprandial blood glucose by slowing gastric emptying; the lack of effect on mean energy intake requires further investigation.

  19. Effects of Intragastric Administration of Tryptophan on the Blood Glucose Response to a Nutrient Drink and Energy Intake, in Lean and Obese Men

    PubMed Central

    Ullrich, Sina S.; Fitzgerald, Penelope C. E.; Giesbertz, Pieter; Steinert, Robert E.; Horowitz, Michael; Feinle-Bisset, Christine

    2018-01-01

    Tryptophan stimulates plasma cholecystokinin and pyloric pressures, both of which slow gastric emptying. Gastric emptying regulates postprandial blood glucose. Tryptophan has been reported to decrease energy intake. We investigated the effects of intragastric tryptophan on the glycaemic response to, and gastric emptying of, a mixed-nutrient drink, and subsequent energy intake. Lean and obese participants (n = 16 each) received intragastric infusions of 1.5 g (“Trp-1.5g”) or 3.0 g (“Trp-3.0g”) tryptophan, or control, and 15 min later consumed a mixed-nutrient drink (56 g carbohydrates). Gastric emptying (13C-acetate breath-test), blood glucose, plasma C-peptide, glucagon, cholecystokinin and tryptophan concentrations were measured (t = 0–60 min). Energy intake was assessed between t = 60–90 min. In lean individuals, Trp-3.0g, but not Trp-1.5g, slowed gastric emptying, reduced C-peptideAUC and increased glucagonAUC (all P < 0.05), but did not significantly decrease the blood glucose response to the drink, stimulate cholecystokinin or reduce mean energy intake, compared with control. In obese individuals, Trp-3.0g, but not Trp-1.5g, tended to slow gastric emptying (P = 0.091), did not affect C-peptideAUC, increased glucagonAUC (P < 0.001) and lowered blood glucose at t = 30 min (P < 0.05), and did not affect cholecystokinin or mean energy intake. In obese individuals, intragastrically administered tryptophan may reduce postprandial blood glucose by slowing gastric emptying; the lack of effect on mean energy intake requires further investigation. PMID:29642492

  20. The development of a pseudo-chamber after balloon pulmonary angioplasty: long-term complications of balloon pulmonary angioplasty.

    PubMed

    Sugiyama, Hisashi; Kise, Hiroaki; Toda, Takako; Hoshiai, Minako

    2016-11-01

    We experienced a rare complication where extravasation developed a pseudo-chamber long after the balloon pulmonary angioplasty for supravalvular pulmonary stenosis. A 3-month-old girl was diagnosed with an anomalous origin of the left coronary artery from the pulmonary artery. She underwent the Takeuchi procedure at 10 months of age. During the follow-up, the supravalvular pulmonary stenosis deteriorated, and was treated by balloon pulmonary angioplasty with the double balloon technique catheter at 6 years of age. Angiography at the main pulmonary artery showed a small amount of extravasation contrast medium after the procedure. Follow-up echocardiography showed a diminished extravasation hemorrhage. Twelve years later, right ventricular enlargement due to pulmonary regurgitation had been observed on echocardiography. In addition, abnormal echo free space was detected at the left posterior of the left atrium. Enhanced computed tomography clearly demonstrated there was an orifice and extent of the pseudo-chamber. Surgical findings revealed a large tear just distal to the coronary tunnel. We speculated that extravasation blood was limited in the perivascular area early after the procedure but eventually reached the non-adhesive oblique pericardial sinus with age. Consequently, pulmonary to oblique pericardial sinus communication was established and looked like a pseudo-chamber long after the procedure. In conclusion, even if extravasation seems to be limited immediately after the balloon pulmonary angioplasty, it could expand for non-adhesive space and could develop a huge blood space like chamber. Long-term careful observation should be necessary for extravasation of pulmonary artery even with surgical adhesion.

  1. The effect of pressure anisotropy on ballooning modes in tokamak plasmas

    NASA Astrophysics Data System (ADS)

    Johnston, A.; Hole, M. J.; Qu, Z. S.; Hezaveh, H.

    2018-06-01

    Edge Localised Modes are thought to be caused by a spectrum of magnetohydrodynamic instabilities, including the ballooning mode. While ballooning modes have been studied extensively both theoretically and experimentally, the focus of the vast majority of this research has been on isotropic plasmas. The prevalence of pressure anisotropy in modern tokamaks thus motivates further study of these modes. This paper presents a numerical analysis of ballooning modes in anisotropic equilibria. The investigation was conducted using the newly-developed codes HELENA+ATF and MISHKA-A, which adds anisotropic physics to equilibria and stability analysis. We have examined the impact of anisotropy on the stability of an n = 30 ballooning mode, confirming results conform to previous calculations in the isotropic limit. Growth rates of ballooning modes in equilibria with different levels of anisotropy were then calculated using the stability code MISHKA-A. The key finding was that the level of anisotropy had a significant impact on ballooning mode growth rates. For {T}\\perp > {T}| | , typical of ICRH heating, the growth rate increases, while for {T}\\perp < {T}| | , typical of neutral beam heating, the growth rate decreases.

  2. Trial of a Paclitaxel-Coated Balloon for Femoropopliteal Artery Disease.

    PubMed

    Rosenfield, Kenneth; Jaff, Michael R; White, Christopher J; Rocha-Singh, Krishna; Mena-Hurtado, Carlos; Metzger, D Christopher; Brodmann, Marianne; Pilger, Ernst; Zeller, Thomas; Krishnan, Prakash; Gammon, Roger; Müller-Hülsbeck, Stefan; Nehler, Mark R; Benenati, James F; Scheinert, Dierk

    2015-07-09

    The treatment of peripheral artery disease with percutaneous transluminal angioplasty is limited by the occurrence of vessel recoil and restenosis. Drug-coated angioplasty balloons deliver antiproliferative agents directly to the artery, potentially improving vessel patency by reducing restenosis. In this single-blind, randomized trial conducted at 54 sites, we assigned, in a 2:1 ratio, 476 patients with symptomatic intermittent claudication or ischemic pain while at rest and angiographically significant atherosclerotic lesions to angioplasty with a paclitaxel-coated balloon or to standard angioplasty. The primary efficacy end point was primary patency of the target lesion at 12 months (defined as freedom from binary restenosis or from the need for target-lesion revascularization). The primary safety end point was a composite of freedom from perioperative death from any cause and freedom at 12 months from limb-related death (i.e., death from a medical complication related to a limb), amputation, and reintervention. The two groups were well matched at baseline; 42.9% of the patients had diabetes, and 34.7% were current smokers. At 12 months, the rate of primary patency among patients who had undergone angioplasty with the drug-coated balloon was superior to that among patients who had undergone conventional angioplasty (65.2% vs. 52.6%, P=0.02). The proportion of patients free from primary safety events was 83.9% with the drug-coated balloon and 79.0% with standard angioplasty (P=0.005 for noninferiority). There were no significant between-group differences in functional outcomes or in the rates of death, amputation, thrombosis, or reintervention. Among patients with symptomatic femoropopliteal peripheral artery disease, percutaneous transluminal angioplasty with a paclitaxel-coated balloon resulted in a rate of primary patency at 12 months that was higher than the rate with angioplasty with a standard balloon. The drug-coated balloon was noninferior to the standard

  3. A balloon-borne prototype for demonstrating the concept of JEM-EUSO

    NASA Astrophysics Data System (ADS)

    von Ballmoos, P.; Santangelo, A.; Adams, J. H.; Barrillon, P.; Bayer, J.; Bertaina, M.; Cafagna, F.; Casolino, M.; Dagoret, S.; Danto, P.; Distratis, G.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Evrard, J.; Gorodetzky, Ph.; Haungs, A.; Jung, A.; Kawasaki, Y.; Medina-Tanco, G.; Mot, B.; Osteria, G.; Parizot, E.; Park, I. H.; Picozza, P.; Prévôt, G.; Prieto, H.; Ricci, M.; Rodríguez Frías, M. D.; Roudil, G.; Scotti, V.; Szabelski, J.; Takizawa, Y.; Tusno, K.

    2014-05-01

    EUSO-BALLOON has been conceived as a pathfinder for JEM-EUSO, a mission concept for a space-borne wide-field telescope monitoring the Earth's nighttime atmosphere with the objective of recording the ultraviolet light from tracks initiated by ultra-high energy cosmic rays. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-BALLOON will serve as a test-bench for the key technologies of JEM-EUSO. EUSO-BALLOON shall perform an end-to-end test of all subsystems and components, and prove the global detection chain while improving our knowledge of the atmospheric and terrestrial ultraviolet background. The balloon-instrument also has the potential to detect for the first time UV-light generated by atmospheric air-shower from above, marking a milestone in the development of UHECR science, and paving the way for any future large scale, space-based ultra-high energy cosmic ray observatory.

  4. Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors

    DOE PAGES

    Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.; ...

    2018-04-24

    Here, we conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hotmore » air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.« less

  5. Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.

    Here, we conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hotmore » air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.« less

  6. Modified jailed balloon technique for bifurcation lesions.

    PubMed

    Saito, Shigeru; Shishido, Koki; Moriyama, Noriaki; Ochiai, Tomoki; Mizuno, Shingo; Yamanaka, Futoshi; Sugitatsu, Kazuya; Tobita, Kazuki; Matsumi, Junya; Tanaka, Yutaka; Murakami, Masato

    2017-12-04

    We propose a new systematic approach in bifurcation lesions, modified jailed balloon technique (M-JBT), and report the first clinical experience. Side branch occlusion brings with a serious complication and occurs in more than 7.0% of cases during bifurcation stenting. A jailed balloon (JB) is introduced into the side branch (SB), while a stent is placed in the main branch (MB) as crossing SB. The size of the JB is half of the MB stent size. While the proximal end of JB attaching to MB stent, both stent and JB are simultaneously inflated with same pressure. JB is removed and then guidewires are recrossed. Kissing balloon dilatation (KBD) and/or T and protrusion (TAP) stenting are applied as needed. Between February 2015 and February 2016, 233 patients (254 bifurcation lesions including 54 left main trunk disease) underwent percutaneous coronary intervention (PCI) using this technique. Procedure success was achieved in all cases. KBD was performed for 183 lesions and TAP stenting was employed for 31 lesions. Occlusion of SV was not observed in any of the patients. Bench test confirmed less deformity of MB stent in M-JBT compared with conventional-JBT. This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting. © 2017 Wiley Periodicals, Inc.

  7. Second-generation endometrial ablation technologies: the hot liquid balloons.

    PubMed

    Vilos, George A; Edris, Fawaz

    2007-12-01

    Hysteroscopic endometrial ablation (HEA) was introduced in the 1980s to treat menorrhagia. Its use required additional training, surgical expertise and specialized equipment to minimize emergent complications such as uterine perforations, thermal injuries and excessive fluid absorption. To overcome these difficulties and concerns, thermal balloon endometrial ablation (TBEA) was introduced in the 1990s. Four hot liquid balloons have been introduced into clinical practice. All systems consist of a catheter (4-10mm diameter), a silicone balloon and a control unit. Liquids used to inflate the balloons include internally heated dextrose in water (ThermaChoice, 87 degrees C), and externally heated glycine (Cavaterm, 78 degrees C), saline (Menotreat, 85 degrees ) and glycerine (Thermablate, 173 degrees C). All balloons require pressurization from 160 to 240 mmHg for treatment cycles of 2 to 10 minutes. Prior to TBEA, preoperative endometrial thinning, including suction curettage, is optional. Several RCTs and cohort studies indicate that the advantages of TBEA include portability, ease of use and short learning curve. In addition, small diameter catheters requiring minimal cervical dilatation (5-7 mm) and short duration of treatment cycles (2-8 min) allow treatment under minimal analgesia/anesthesia requirements in a clinic setting. Following TBEA serious adverse events, including thermal injuries to viscera have been experienced. To minimize such injuries some surgeons advocate the use of routine post-dilatation hysteroscopy and/or ultrasonography to confirm correct intrauterine placement of the balloon prior to initiating the treatment cycle. After 10 years of clinical practice, TBEA is thought to be the preferred first-line surgical treatment of menorrhagia in appropriately selected candidates. Economic modeling also suggested that TBEA may be more cost-effective than HEA.

  8. Scientific ballooning. Proceedings. PSB Meeting of the COSPAR Panel on Technical Problems Related to Scientific Ballooning which was held during the Thirtieth COSPAR Scientific Assembly, Hamburg (Germany), 11 - 21 Jul 1994.

    NASA Astrophysics Data System (ADS)

    Riedler, W.; Torkar, K.

    1996-05-01

    This issue is grouped into sections on materials, design, performance and analysis of balloons, reviews of major national and international balloon programmes, novel instrumentation and systems for scientific ballooning, and selected recent scientific observations.

  9. Generalised ballooning theory of two-dimensional tokamak modes

    NASA Astrophysics Data System (ADS)

    Abdoul, P. A.; Dickinson, D.; Roach, C. M.; Wilson, H. R.

    2018-02-01

    In this work, using solutions from a local gyrokinetic flux-tube code combined with higher order ballooning theory, a new analytical approach is developed to reconstruct the global linear mode structure with associated global mode frequency. In addition to the isolated mode (IM), which usually peaks on the outboard mid-plane, the higher order ballooning theory has also captured other types of less unstable global modes: (a) the weakly asymmetric ballooning theory (WABT) predicts a mixed mode (MM) that undergoes a small poloidal shift away from the outboard mid-plane, (b) a relatively more stable general mode (GM) balloons on the top (or bottom) of the tokamak plasma. In this paper, an analytic approach is developed to combine these disconnected analytical limits into a single generalised ballooning theory. This is used to investigate how an IM behaves under the effect of sheared toroidal flow. For small values of flow an IM initially converts into a MM where the results of WABT are recaptured, and eventually, as the flow increases, the mode asymptotically becomes a GM on the top (or bottom) of the plasma. This may be an ingredient in models for understanding why in some experimental scenarios, instead of large edge localised modes (ELMs), small ELMs are observed. Finally, our theory can have other important consequences, especially for calculations involving Reynolds stress driven intrinsic rotation through the radial asymmetry in the global mode structures. Understanding the intrinsic rotation is significant because external torque in a plasma the size of ITER is expected to be relatively low.

  10. High Altitude Infrasound Measurements using Balloon-Borne Arrays

    NASA Astrophysics Data System (ADS)

    Bowman, D. C.; Johnson, C. S.; Gupta, R. A.; Anderson, J.; Lees, J. M.; Drob, D. P.; Phillips, D.

    2015-12-01

    For the last fifty years, almost all infrasound sensors have been located on the Earth's surface. A few experiments consisting of microphones on poles and tethered aerostats comprise the remainder. Such surface and near-surface arrays likely do not capture the full diversity of acoustic signals in the atmosphere. Here, we describe results from a balloon mounted infrasound array that reached altitudes of up to 38 km (the middle stratosphere). The balloon drifted at the ambient wind speed, resulting in a near total reduction in wind noise. Signals consistent with tropospheric turbulence were detected. A spectral peak in the ocean microbarom range (0.12 - 0.35 Hz) was present on balloon-mounted sensors but not on static infrasound stations near the flight path. A strong 18 Hz signal, possibly related to building ventilation systems, was observed in the stratosphere. A wide variety of other narrow band acoustic signals of uncertain provenance were present throughout the flight, but were absent in simultaneous recordings from nearby ground stations. Similar phenomena were present in spectrograms from the last balloon infrasound campaign in the 1960s. Our results suggest that the infrasonic wave field in the stratosphere is very different from that which is readily detectable on surface stations. This has implications for modeling acoustic energy transfer between the lower and upper atmosphere as well as the detection of novel acoustic signals that never reach the ground. Our work provides valuable constraints on a proposed mission to detect earthquakes on Venus using balloon-borne infrasound sensors.

  11. The Liege-balloon program. [balloon-borne instruments for high-spectral resolution observations of the sun

    NASA Technical Reports Server (NTRS)

    Zander, R.

    1974-01-01

    The Liege-balloon program is intended to make high-spectral resolution observations of the sun in the near- and intermediate infrared regions not accessible from the ground. A description of the equipment, followed by a summary of the data obtained till now is presented. Except for ozone whose maximum of concentration lies near 25 Km altitude, the residual mass distribution of the other mentioned molecules decreases with altitude. This is a self-explanatory argument for carrying out spectroscopic observations from platforms transcending the densest layers of the earth's atmosphere. The Liege balloon equipment is primarily intended for very high-resolution solar observations from about 27-30 Km altitude, in all spectral regions between 1.5 and 15.0 microns, not accessible from the ground.

  12. Development of a 5,000 m(3) super-pressure balloon with a diamond-shaped net

    NASA Astrophysics Data System (ADS)

    Saito, Yoshitaka; Tanaka, Shigeki; Nakashino, Kyoichi; Matsushima, Kiyoho; Goto, Ken; Furuta, Ryosuke; Domoto, Kodai; Akita, Daisuke; Hashimoto, Hiroyuki

    A light super-pressure balloon of which weight will be comparable to the weight of the zero-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m(3) balloon. A flight test of a 3,000 m(3) balloon in the tandem balloon configuration with a 15,000 m(3) zero-pressure balloon was performed in 2012. Although a small gas leak occurred in the super-pressure balloon at the differential pressure of 400 to 500 Pa, the differential pressure reached the highest value of 814 Pa and kept positive through the level flight lasting for 25 minutes due to its slow leakage. To avoid a possible stress concentration to films at the polar area, a new design setting the meridian length of the balloon gore film equal to the length of the net was adopted. A 3-m balloon with the design was developed and its capacity to resist pressure at room temperature and at -30 (°) C was checked through the ground inflation tests. In 2013, a balloon of the same model was launched in the tandem balloon configuration with 2 kg rubber balloons. It was confirmed that the balloon could withstand the maximum differential pressure of 6,280 Pa, could withstand the differential pressure of 5,600 Pa for 2 hours, and there was a small gas leak through a hole with an area of 0.4 mm(2) which was also found in the ground leakage test. These results indicated that the improvement was adequate and there was no problem for the super-pressure balloon to fly in the environment of the stratosphere except for the problem of the small gas leak. In 2014, a flight test of a 5,000 m(3) balloon will be performed. In this paper, after reviewing the method to cover a balloon with a diamond-shaped net, the current status of the development will be reported.

  13. Robotic weather balloon launchers spread in Alaska

    NASA Astrophysics Data System (ADS)

    Rosen, Julia

    2018-04-01

    Last week, things began stirring inside the truck-size box that sat among melting piles of snow at the airport in Fairbanks, Alaska. Before long, the roof of the box yawned open and a weather balloon took off into the sunny afternoon, instruments dangling. The entire launch was triggered with the touch of a button, 5 kilometers away at an office of the National Weather Service (NWS). The flight was smooth, just one of hundreds of twice-daily balloon launches around the world that radio back crucial data for weather forecasts. But most of those balloons are launched by people; the robotic launchers, which are rolling out across Alaska, are proving to be controversial. NWS says the autolaunchers will save money and free up staff to work on more pressing matters. But representatives of the employee union question their reliability, and say they will hasten the end of Alaska's remote weather offices, where forecasting duties and hours have already been slashed.

  14. Astrobiology Exploration Strategies for the Mars Polar Regions Using Balloon Platforms

    NASA Technical Reports Server (NTRS)

    Mahaffy, P. R.; Atreya, S. A.; Fairbrother, D. A.; Farrell, W. M.; Gorevan, S.; Jones, J.; Mitrofanov, I.; Scott, J.

    2003-01-01

    Montgolfiere balloons can provide a unique near-surface platform for an extended traverse over the polar regions of Mars. During the polar summer, such solar powered balloons would remain in the constant sun of the polar summer and could remain airborne for many weeks or even months as the atmospheric circulation would drive the balloons around the polar region many times before the balloon would cross the terminator. Such a platform for scientific measurements could provide in situ sampling of the atmosphere for trace disequilibrium species that might be indicators of present geological or biological activity in this region. It could furthermore provide high resolution imaging, deep electromagnetic (EM) sounding for subsurface stratigraphy and liquid water, and high spatial resolution neutron measurements of subsurface ice. Technologies for robust balloon deployment on entry and controlled encounters with the surface and near subsurface for sample acquisition in otherwise inaccessible regions are presently being studied and developed with support from NASA.

  15. Astrobiology Exploration Strategies for the Mars Polar Regions Using Balloon Platforms

    NASA Technical Reports Server (NTRS)

    Mahaffy, P. R.; Atreya, S. A.; Fairbrother, D. A.; Farrell, W. M.; Gorevan, S.; Jones, J.; Mitrofanov, I.; Scott, J.

    2003-01-01

    Montgolfiere balloons can provide a unique near-surface platform for an extended traverse over the polar regions of Mars. During the polar summer, such solar powered balloons would remain in the constant sun of the polar summer and could remain airborne for many weeks or even months as the atmospheric circulation would drive the balloons around the polar region many times before the balloon would cross the terminator. Such a platform for scientific measurements could provide in situ sampling of the atmosphere for trace disequilibrium species that might be indicators of present geological or biological activity in this regon. It could furthermore provide high resolution imaging, deep electromagnetic (EM) sounding for subsurface stratigraphy and liquid water, and high spatial resolution neutron measurements of subsurface ice. Technologies for robust balloon deployment on entry and controlled encounters with the surface and near subsurface for sample acquisition in otherwise inaccessible regions are presently being studied and developed with support from NASA.

  16. JUBA (Joint UAS-Balloon Activities) Final Campaign Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dexheimer, Darielle; Apple, Monty; Callow, Diane Schafer

    Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, JUBA was a collaborative exercise between SNL Orgs. 6533 & 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and UAS on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the ARM AMF3 site at Oliktok Point, Alaska. The Restricted Airspace occupies a 2 nautical mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 – 08/10/17. Atmospheric measurements frommore » tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability.« less

  17. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    While large compared to a human, BARREL balloons are actually much smaller than typical science balloons, which can be as large as a football field. Credit: NASA/Goddard/BARREL/Brett Anderson Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  18. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2017-12-08

    The BARREL team at Halley Research Station in Antarctica, work to inflate a balloon. The long tube on the left is the inflation tube used to fill the top of the balloon with helium. Credit: NASA/Goddard/BARREL Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy.NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission.Follow us on TwitterLike us on FacebookFind us on Instagram

  19. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    Release of a BARREL balloon. The launch crew can be seen on the right holding the payload as the top of the balloon moves overhead where they can release it. Credit: NASA/Goddard/BARREL Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy.NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission.Follow us on TwitterLike us on FacebookFind us on Instagram

  20. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    Getting ready to lay out a BARREL balloon to prepare for inflation. The helium stillages used to fill the balloon can be seen in the background. Credit: NASA/Goddard/BARREL/Brett Anderson Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  1. 75 FR 77673 - National Environmental Policy Act: Scientific Balloon Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... implementation of the Proposed Action are summarized below. Airspace and Balloon Operations: No adverse impacts to airspace management or balloon operations are anticipated under this proposal. CSBF would continue... minimal. Air emissions would not be perceptibly [[Page 77674

  2. Catalytic Generation of Lift Gases for Balloons

    NASA Technical Reports Server (NTRS)

    Zubrin, Robert; Berggren, Mark

    2011-01-01

    A lift-gas cracker (LGC) is an apparatus that generates a low-molecular-weight gas (mostly hydrogen with smaller amounts of carbon monoxide and/or carbon dioxide) at low gauge pressure by methanol reforming. LGCs are undergoing development for use as sources of buoyant gases for filling zero-gauge-pressure meteorological and scientific balloons in remote locations where heavy, high-pressure helium cylinders are not readily available. LGCs could also be used aboard large, zero-gauge-pressure, stratospheric research balloons to extend the duration of flight.

  3. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopera, Jorge E., E-mail: Lopera@uthscsa.ed; Alvarez, Alex; Trimmer, Clayton

    2009-01-15

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm{sup 3}, respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containingmore » a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.« less

  4. Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation.

    PubMed

    Ghosh, Justin; Sepahpour, Ali; Chan, Kim H; Singarayar, Suresh; McGuire, Mark A

    2013-05-01

    Persistent phrenic nerve palsy is the most frequent complication of cryoballoon ablation for atrial fibrillation and can be disabling. To describe a technique-immediate balloon deflation (IBD)-for the prevention of persistent phrenic nerve palsy, provide data for its use, and describe in vitro simulations performed to investigate the effect of IBD on the atrium and pulmonary vein. Cryoballoon procedures for atrial fibrillation were analyzed retrospectively (n = 130). IBD was performed in patients developing phrenic nerve dysfunction (n = 22). In vitro simulations were performed by using phantoms. No adverse events occurred, and all patients recovered normal phrenic nerve function before leaving the procedure room. No patient developed persistent phrenic nerve palsy. The mean cryoablation time to onset of phrenic nerve dysfunction was 144 ± 64 seconds. Transient phrenic nerve dysfunction was seen more frequently with the 23-mm balloon than with the 28-mm balloon (11 of 39 cases vs 11 of 81 cases; P = .036). Balloon rewarming was faster following IBD. The time to return to 0 and 20° C was shorter in the IBD group (6.7 vs 8.9 seconds; P = .007 and 16.7 vs 37.6 seconds; P<.0001). In vitro simulations confirmed that IBD caused more rapid tissue warming (time to 0°C, 14.0 ± 3.4 seconds vs 46.0 ± 8.1; P = .0001) and is unlikely to damage the atrium or pulmonary vein. IBD results in more rapid tissue rewarming, causes no adverse events, and appears to prevent persistent phrenic nerve palsy. Simulations suggest that IBD is unlikely to damage the atrium or pulmonary vein. Copyright © 2013 Heart Rhythm Society. All rights reserved.

  5. First-in-human experience using the Volcano VIBE-RX vascular imaging balloon catheter system (Volcano IVUS-guided Balloon Evaluation - New Zealand: VIBE-NZ Study).

    PubMed

    Watson, Timothy; El-Jack, Seifeddin; Stewart, James T; Ormiston, John

    2013-09-01

    Intravascular ultrasound (IVUS) is a proven and safe imaging modality used to guide percutaneous coronary intervention (PCI). The Volcano VIBE™ RX Vascular Imaging Balloon Catheter is a novel rapid exchange, 0.014" wire-compatible multi-lumen conventional balloon catheter modified with the addition of an IVUS transducer proximal to the balloon, delivered via a standard 6 Fr sheath. We sought to evaluate the safety, balloon performance, and image quality of the VIBE™ RX in patients scheduled for coronary intervention. Patients aged >21 and <85 years with single or multivessel coronary disease scheduled for PCI due to coronary ischaemic symptoms were included. Those with angiographic features that precluded the safe or informative use of the device were excluded. Twenty-nine patients having angiography because of ischaemic symptoms underwent 44 VIBE RX imaging runs, with balloon dilation in 20. Successful device deployment was achieved in all but one patient. All images were adequate and reproducible. One patient had a non-ST-elevation MI felt to be due to the complexity of the procedure rather than directly related to the VIBE™ RX. The study demonstrated the safety and effectiveness of the VIBE™ RX for its intended purpose with minimal failure rate and no directly related complications.

  6. The glider balloon: a useful device for the treatment of bifurcation lesions.

    PubMed

    Briguori, Carlo; Visconti, Gabriella; Donahue, Michael; Chiariello, Giovanni Alfonso; Focaccio, Amelia

    2013-10-09

    Final kissing balloon dilatation (FKBD) is a recommended final step in case of treatment of bifurcation lesions by two stents approaches. Furthermore, dilatation of the side branch (SB) may be necessary following main vessel (MV) stenting. Occasionally, recrossing the stent struts with a balloon is hampered because the tip hits a stent strut. The Glider (TriReme Medical, Pleasanton, CA) is a dedicated balloon designed for crossing through struts of deployed stents toward a SB. From October 2010 to January 2012, FKBD was attempted in 236 consecutive bifurcation lesions treated in our Institution. FKBD was successfully performed by conventional balloon catheters in 221 (93.5%) lesions (Conventional group). In the remaining 15 (6.5%) lesions, where a conventional balloon failed to cross the stent strut, the Glider balloon was attempted (Glider group). The angle beta (between the axis of the MV after the branch point and the SB axis at the point of divergence) was wider in the Glider group (83±17° versus 65±27°; p=0.032). A trend toward an higher rate of the true bifurcation lesions was observed in the Glider group (93% versus 70.5%; p=0.07). The Glider balloon successfully crossed through MV stent struts toward a SB in 12 patients (80%), whereas failed in the remaining 3 patients. The Glider balloon represents an unique bail-out device which offers an effective rescue strategy for recrossing stent struts during complex bifurcation stenting. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach.

    PubMed

    Morey, Allen F; Cefalu, Christopher A; Hudak, Steven J

    2013-02-01

    Traditional placement of inflatable penile prosthesis (IPP) reservoirs and/or artificial urinary sphincter (AUS) balloons into the space of Retzius may be challenging following major pelvic surgery. The aim of this study is to report our 1-year experience using a novel technique for high balloon/reservoir placement beneath the rectus abdominus muscle, thus completely obviating deep pelvic dissection during prosthetic urologic surgery. A retrospective review of all patients who underwent IPP and/or AUS placement between June 2011 and June 2012 was performed. All had AUS balloons and/or IPP reservoirs placed in a submuscular location by bluntly tunneling through the external inguinal ring into a potential space between the transversalis fascia and the rectus abdominus muscle using a long, angled, lung grasping clamp. Patient demographics, perioperative outcomes, and initial follow-up patient-reported outcomes were reviewed. During the study period, 120 submuscular balloons/reservoirs were inserted in 107 consecutive patients who underwent placement of an IPP (61 patients), AUS (33 patients), or both (13 patients). Among our 48 most recent patients, 41 (85%) reported they were totally unable to feel their balloon/reservoir, and all but two patients reported no bother from the submuscular balloon/reservoir placement. Of the 120 total submuscular balloons and reservoirs, surgical time and outcomes of the prosthetic procedures appeared similar to those placed using traditional methods; two reservoirs required revision surgery for repositioning. High submuscular placement of genitourinary prosthetic balloons and reservoirs via a transscrotal approach is both safely and effective, while avoiding deep retropubic dissection. © 2012 International Society for Sexual Medicine.

  8. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    An iceberg as viewed from the bow of the RRS Ernest Shackleton a few days before the BARREL team reached Halley Research Station in Antarctica. This research vessel regularly carries scientists and supplies to Halley. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch 20 more balloons in 2014

  9. NASA’s BARREL Mission Launches 20 Balloons

    NASA Image and Video Library

    2017-12-08

    Arrival of the RRS Ernest Shackleton near Halley Research Station in Antarctica. The Shackleton is the regular resupply ship for the station and it also brought in some of the BARREL team scientists. The long tether is for the ship’s mooring. Credit: NASA --- In Antarctica in January, 2013 – the summer at the South Pole – scientists launched 20 balloons up into the air to study an enduring mystery of space weather: when the giant radiation belts surrounding Earth lose material, where do the extra particles actually go? The mission is called BARREL (Balloon Array for Radiation belt Relativistic Electron Losses) and it is led by physicist Robyn Millan of Dartmouth College in Hanover, NH. Millan provided photographs from the team’s time in Antarctica. The team launched a balloon every day or two into the circumpolar winds that circulate around the pole. Each balloon floated for anywhere from 3 to 40 days, measuring X-rays produced by fast-moving electrons high up in the atmosphere. BARREL works hand in hand with another NASA mission called the Van Allen Probes, which travels through the Van Allen radiation belts surrounding Earth. The belts wax and wane over time in response to incoming energy and material from the sun, sometimes intensifying the radiation through which satellites must travel. Scientists wish to understand this process better, and even provide forecasts of this space weather, in order to protect our spacecraft. As the Van Allen Probes were observing what was happening in the belts, BARREL tracked electrons that precipitated out of the belts and hurtled down Earth’s magnetic field lines toward the poles. By comparing data, scientists will be able to track how what’s happening in the belts correlates to the loss of particles – information that can help us understand this mysterious, dynamic region that can impact spacecraft. Having launched balloons in early 2013, the team is back at home building the next set of payloads. They will launch

  10. NASA Balloon Highlights 2015-2017

    NASA Technical Reports Server (NTRS)

    Fairbrother, Debora

    2017-01-01

    The NASA Balloon Program provides low-cost, quick response, near space access to NASAs science Community for conducting Cutting Edge Science Investigations. Serve as a technology development platform. Excellent training for NASA scientists and engineers.

  11. A local network integrated into a balloon-borne apparatus

    NASA Astrophysics Data System (ADS)

    Imori, Masatosi; Ueda, Ikuo; Shimamura, Kotaro; Maeno, Tadashi; Murata, Takahiro; Sasaki, Makoto; Matsunaga, Hiroyuki; Matsumoto, Hiroshi; Shikaze, Yoshiaki; Anraku, Kazuaki; Matsui, Nagataka; Yamagami, Takamasa

    A local network is incorporated into an apparatus for a balloon-borne experiment. A balloon-borne system implemented in the apparatus is composed of subsystems interconnected through a local network, which introduces modular architecture into the system. The network decomposes the balloon-borne system into subsystems, which are similarly structured from the point of view that the systems is kept under the control of a ground station. The subsystem is functionally self-contained and electrically independent. A computer is integrated into a subsystem, keeping the subsystem under the control. An independent group of batteries, being dedicated to a subsystem, supplies the whole electricity of the subsystem. The subsystem could be turned on and off independently of the other subsystems. So communication among the subsystems needs to be based on such a protocol that could guarantee the independence of the individual subsystems. An Omninet protocol is employed to network the subsystems. A ground station sends commands to the balloon-borne system. The command is received and executed at the system, then results of the execution are returned to the ground station. Various commands are available so that the system borne on a balloon could be controlled and monitored remotely from the ground station. A subsystem responds to a specific group of commands. A command is received by a transceiver subsystem and then transferred through the network to the subsystem to which the command is addressed. Then the subsystem executes the command and returns results to the transceiver subsystem, where the results are telemetered to the ground station. The network enhances independence of the individual subsystems, which enables programs of the individual subsystems to be coded independently. Independence facilitates development and debugging of programs, improving the quality of the system borne on a balloon.

  12. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    PubMed

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2013-03-22

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  13. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    PubMed

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2014-04-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  14. [Pressure-volume recording of PTCA catheters with balloons of lower and higher compliance].

    PubMed

    Werner, C; Bloss, P; Kiessling, D; Patzschke, H; Unverdorben, M; Vallbracht, C

    1999-11-01

    In this report, the results of complementary studies of pressure-volume (p-V) measurements on balloon catheters with balloons of low (LC) and high compliance (HC) used for percutaneous transluminal coronary angioplasty are discussed. The measurements were performed with balloons unconfined in air (free dilatation) and also confined in different shells. In the case of rigid shells, a surprisingly high self-expansion of the catheters was found. Although this self-expansion does not contribute to the radial dilatation, it cannot be neglected, but must be taken into account when the success of balloon dilatation is determined on the basis of measured p-V curves. The investigations performed using wrapped shells clearly show the different dilatation properties of LC and HC balloons. The results provide important information on the feasibility of controlled balloon dilatation on the basis of p-V measurements performed on-line during PTCA.

  15. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    PubMed

    Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young

    2015-01-01

    The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20-1200 mL) in the balloon failure group and 60 mL (5-500 mL) in the balloon success group (p<0.01). Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  16. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients

    PubMed Central

    Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young

    2015-01-01

    Purpose The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. Methods We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Results Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20–1200 mL) in the balloon failure group and 60 mL (5–500 mL) in the balloon success group (p<0.01). Conclusion Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance. PMID:26263014

  17. On the feasibility of closed-loop control of intra-aortic balloon pumping

    NASA Technical Reports Server (NTRS)

    Clark, J. W., Jr.; Bourland, H. M.; Kane, G. R.

    1973-01-01

    A closed-loop control scheme for the control of intra-aortic balloon pumping has been developed and tested in dog experiments. A performance index reflecting the general objectives of balloon-assist pumping is developed and a modified steepest ascent control algorithm is utilized for the selection of a proper operating point for the balloon during its pumping cycle. This paper attempts to indicate the feasibility of closed-loop control of balloon pumping, and particularly its flexibility in achieving both diastolic augmentation of mean aortic pressure and control of the level of end-diastolic pressure (EDP) an important factor in reducing heart work.

  18. Cryo-balloon catheter position planning using AFiT

    NASA Astrophysics Data System (ADS)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  19. Comparative evaluation of intragastric bile acids and hepatobiliary scintigraphy in the diagnosis of duodenogastric reflux.

    PubMed

    Chen, Teng-Fei; Yadav, Praveen K; Wu, Rui-Jin; Yu, Wei-Hua; Liu, Chang-Qin; Lin, Hui; Liu, Zhan-Ju

    2013-01-01

    To assess the diagnostic value of a combination of intragastric bile acids and hepatobiliary scintigraphy in the detection of duodenogastric reflux (DGR). The study contained 99 patients with DGR and 70 healthy volunteers who made up the control group. The diagnosis was based on the combination of several objective arguments: a long history of gastric symptoms (i.e., nausea, epigastric pain, and/or bilious vomiting) poorly responsive to medical treatment, gastroesophageal reflux symptoms unresponsive to proton-pump inhibitors, gastritis on upper gastrointestinal (GI) endoscopy and/or at histology, presence of a bilious gastric lake at > 1 upper GI endoscopy, pathologic 24-h intragastric bile monitoring with the Bilitec device. Gastric juice was aspirated in the GI endoscopy and total bile acid (TBA), total bilirubin (TBIL) and direct bilirubin (DBIL) were tested in the clinical laboratory. Continuous data of gastric juice were compared between each group using the independent-samples Mann-Whitney U-test and their relationship was analysed by Spearman's rank correlation test and Fisher's linear discriminant analysis. Histopathology of DGR patients and 23 patients with chronic atrophic gastritis was compared by clinical pathologists. Using the Independent-samples Mann-Whitney U-test, DGR index (DGRi) was calculated in 28 patients of DGR group and 19 persons of control group who were subjected to hepatobiliary scintigraphy. Receiver operating characteristic curve was made to determine the sensitivity and specificity of these two methods in the diagnosis of DGR. The group of patients with DGR showed a statistically higher prevalence of epigastric pain in comparison with control group. There was no significant difference between the histology of gastric mucosa with atrophic gastritis and duodenogastric reflux. The bile acid levels of DGR patients were significantly higher than the control values (Z: TBA: -8.916, DBIL: -3.914, TBIL: -6.197, all P < 0.001). Two of three

  20. Comparative evaluation of intragastric bile acids and hepatobiliary scintigraphy in the diagnosis of duodenogastric reflux

    PubMed Central

    Chen, Teng-Fei; Yadav, Praveen K; Wu, Rui-Jin; Yu, Wei-Hua; Liu, Chang-Qin; Lin, Hui; Liu, Zhan-Ju

    2013-01-01

    AIM: To assess the diagnostic value of a combination of intragastric bile acids and hepatobiliary scintigraphy in the detection of duodenogastric reflux (DGR). METHODS: The study contained 99 patients with DGR and 70 healthy volunteers who made up the control group. The diagnosis was based on the combination of several objective arguments: a long history of gastric symptoms (i.e., nausea, epigastric pain, and/or bilious vomiting) poorly responsive to medical treatment, gastroesophageal reflux symptoms unresponsive to proton-pump inhibitors, gastritis on upper gastrointestinal (GI) endoscopy and/or at histology, presence of a bilious gastric lake at > 1 upper GI endoscopy, pathologic 24-h intragastric bile monitoring with the Bilitec device. Gastric juice was aspirated in the GI endoscopy and total bile acid (TBA), total bilirubin (TBIL) and direct bilirubin (DBIL) were tested in the clinical laboratory. Continuous data of gastric juice were compared between each group using the independent-samples Mann-Whitney U-test and their relationship was analysed by Spearman’s rank correlation test and Fisher’s linear discriminant analysis. Histopathology of DGR patients and 23 patients with chronic atrophic gastritis was compared by clinical pathologists. Using the Independent-samples Mann-Whitney U-test, DGR index (DGRi) was calculated in 28 patients of DGR group and 19 persons of control group who were subjected to hepatobiliary scintigraphy. Receiver operating characteristic curve was made to determine the sensitivity and specificity of these two methods in the diagnosis of DGR. RESULTS: The group of patients with DGR showed a statistically higher prevalence of epigastric pain in comparison with control group. There was no significant difference between the histology of gastric mucosa with atrophic gastritis and duodenogastric reflux. The bile acid levels of DGR patients were significantly higher than the control values (Z: TBA: -8.916, DBIL: -3.914, TBIL: -6.197, all

  1. Nonlinear ballooning modes in tokamaks: stability and saturation

    NASA Astrophysics Data System (ADS)

    Ham, C. J.; Cowley, S. C.; Brochard, G.; Wilson, H. R.

    2018-07-01

    The nonlinear dynamics of magneto-hydrodynamic ballooning mode perturbations is conjectured to be characterised by the motion of isolated elliptical flux tubes. The theory of stability, dynamics and saturation of such tubes in tokamaks is developed using a generalised Archimedes’ principle. The equation of motion for a tube moving against a drag force in a general axisymmetric equilibrium is derived and then applied to a simplified ‘s–α’ equilibrium. The perturbed nonlinear tube equilibrium (saturated) states are investigated in an ‘s–α’ equilibrium with specific pressure and magnetic shear profiles. The energy of these nonlinear (ballooning) saturated states is calculated. In some cases, particularly at low magnetic shear, these finitely displaced states can have a lower energy than the equilibrium state even if the profile is linearly stable to ballooning modes (infinitesimal tube displacements) at all radii. Thus nonlinear ballooning modes can be metastable. The amplitude of the saturated tube displacement in such cases can be as large as the pressure gradient scale length. We conjecture that triggering a transition into these filamentary states can lead to hard instability limits. A short survey of different pressure profiles is presented to illustrate the variety of behaviour of perturbed elliptical flux tubes.

  2. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    PubMed Central

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792

  3. Balloon crash damage and injuries: an analysis of 86 accidents, 2000-2004.

    PubMed

    de Voogt, Alexander J; van Doorn, Robert R A

    2006-05-01

    General aviation accounts for the majority of aviation crashes and casualties in the United States. The role of ballooning in these statistics is not regularly studied. Since 2001, the National Transportation and Safety Board has made its accident reports more readily available, which presents opportunities for further study. This study analyzes and compares a 5-yr period of accident reports and includes an analysis of injuries and balloon damage in hot-air and gas balloon accidents. Balloon crash 2-page briefs and 5-page accident reports published by the National Transportation and Safety Board for the 5-yr time period 2000-2004 were examined. Data collected in the investigation of these crashes were analyzed and compared with the epidemiological data collected in earlier research. In 86 crashes during a 5-yr period, there were 4 fatalities and 75 people were seriously injured. Only one accident was reported involving a student pilot. Broken ankles and legs have been the most commonly recorded serious injury, but could not be linked to the severity of damage to the balloon. The absence of student pilot accidents may be explained by possible stricter supervision. Balloon basket and envelopes appear of sufficient quality to withstand crashes, but improving the protection of passengers during hard landings should help to decrease the number of serious injuries in ballooning.

  4. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon

    PubMed Central

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2013-01-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM. PMID:23524491

  5. [Imprints of coronary plaque particles in the PTCA balloon surface during the dilatation processing].

    PubMed

    Werner, D; Behrend, D; Schmitz, K P; Urbaszek, W

    1995-05-01

    Seventy-six PTCA-balloons after coronary angioplasty were studied for superficial changes using scanning electron microscopy (SEM) after fixing in glutardialdehyde. Coronary plaque particles were identified on the balloon surface in 52 cases (68%). Twelve new and unused balloons were subjected to the same chemical treatment and SEM showed no imprints. The average length of the longest imprinted plaques was 128 +/- 201 microns and the average number of plaque particles per balloon was 4.9 +/- 2.7. The maximal dilatation pressure and the number of dilatations showed no influence on the impregnation of plaque particles. However, longer plaque imprints tended to occur under low dilatation pressure. Imprints of plaque particles were significantly higher in patients with low cholesterol (p = 0.0001) and low triglycerides (p = 0.0016). No correlation was seen between imprint length and lipid levels. Similarly, the different balloon materials (polyethylene, polyolefincopolymer) showed no significant differences with regard to plaque occurrence. The PTCA-balloons, plaque particles and six coronary plaques obtained after endatherectomy were subjected to energy dispersive x-ray analysis (EDX) under SEM as EDX reveals qualitative and quantitative information about the structural elements. Highly significant differences in calcium, sodium, phosphorus and silicon contents (p = 0.0000) between plaque particles and balloon surface were observed, owing to the absence of these in balloon material. Thus EDX offers additional advantages over SEM in that it clearly differentiates deformed balloon surface, plaque particle, and retained contrast medium. Plaque particles can be recovered from balloon surfaces after PTCA. Depending upon their size, they could lead to coronary spasm or microembolic phenomenon.

  6. Stability analysis and trend study of a balloon tethered in a wind, with experimental comparisons

    NASA Technical Reports Server (NTRS)

    Redd, L. T.; Bland, S. R.; Bennett, R. M.

    1973-01-01

    A stability analysis and trend study for a balloon tethered in a steady wind are presented. The linearized, stability-derivative type analysis includes balloon aerodynamics, buoyancy, mass (including apparent mass), and static forces resulting from the tether cable. The analysis has been applied to a balloon 7.64 m in length, and the results are compared with those from tow tests of this balloon. This comparison shows that the analysis gives reasonable predictions for the damping, frequencies, modes of motion, and stability boundaries exhibited by the balloon. A trend study for the 7.64-m balloon was made to illustrate how the stability boundaries are affected by changes in individual stability parameters. The trends indicated in this study may also be applicable to many other tethered-balloon systems.

  7. Dislodgement of variceal bands after esophageal balloon tamponade for variceal bleeding.

    PubMed

    Mogrovejo, Estela; Manickam, Palaniappan; Polidori, Gregg; Cappell, Mitchell S

    2014-01-01

    A 43-year-old male with alcoholic cirrhosis underwent EGD for hematemesis which revealed bleeding, grade II, lower esophageal varices that were endoscopically ligated with 6 bands. All the bands remained attached to varices at the completion of EGD. Despite apparent initial hemostasis, balloon tamponade was performed one hour later for suspected continued bleeding. Due to suspected continuing bleeding, EGD was repeated 4 h after initial EGD, and 3 h after balloon tamponade. This EGD revealed the esophageal varices; none of the bands remaining on esophageal mucosa; multiple mucosal stigmata likely from trauma at initial site of variceal bands before dislodgement; and 3 dislodged bands in gastric body, duodenal bulb, or descending duodenum. The patient expired 17 h thereafter from hypovolemic shock. This single report may suggest an apparently novel, balloon tamponade complication: dislodgement of previously placed, endoscopic bands. The proposed pathophysiology is release of bands by stretching entrapped, esophageal mucosa during esophageal balloon tamponade. This complication, if confirmed, might render balloon tamponade a less desirable option very soon after band ligation.

  8. Time-dependent strains and stresses in a pumpkin balloon

    NASA Technical Reports Server (NTRS)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2006-01-01

    This paper presents a study of pumpkin-shaped superpressure balloons, consisting of gores made from a thin polymeric film attached to high stiffness, meridional tendons. This type of design is being used for the NASA ULDB balloons. The gore film shows considerable time-dependent stress relaxation, whereas the behaviour of the tendons is essentially time-independent. Upon inflation and pressurization, the "instantaneous", i.e. linear-elastic strain and stress distribution in the film show significantly higher values in the meridional direction. However, over time, and due to the biaxial visco-elastic stress relaxation of the the material, the hoop strains increase and the meridional stresses decrease, whereas the remaining strain and stress components remain substantially unchanged. These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission, both in terms of the material performance and the overall stability of the shape of the balloon. An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter, 48 gore pumpkin balloon is presented. The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature. The results show good correlation with a numerical study, using the ABAQUS finite-element package, that includes a widely used model of the visco-elastic response of the gore material:

  9. A hard X-ray experiment for long-duration balloon flights

    NASA Astrophysics Data System (ADS)

    Johnson, W. N.; Kurfess, J. D.; Strickman, M. S.; Saulnier, D. M.

    The Naval Research Lab has developed a balloon-borne hard X-ray experiment which is designed for 60- to 90-day flight durations soon to be available with around the world Sky Anchor or RACOON balloon flights. The experiment's scintillation detector is sensitive to the 15 - 250 keV X-ray energy range. The experiment includes three microcomputer systems which control the data acquisition and provide the orientation and navigation information required for global balloon flights. The data system supports global data communications utilizing the GOES satellite as well as high bit rate communications through L-band li line-of-site transmissions

  10. Balloon dilation of congenital supravalvular pulmonic stenosis in a dog.

    PubMed

    Treseder, Julia R; Jung, SeungWoo

    2017-03-30

    Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a case of supravalvular pulmonic stenosis diagnosed echocardiographically and angiographically in which a significant reduction in pressure gradient was achieved with balloon dilation alone is presented.

  11. [The Application of Internal Iliac Artery Balloon Occlusion in Pernicious Placenta Previa].

    PubMed

    Qi, Xiao-Rong; Liu, Xing-Hui; You, Yong; Wang, Xiao-Dong; Zhou, Rong; Xing, Ai-Yun; Zhang, Li; Ning, Gang; Zhao, Fu-Min; Li, Kai-Ming

    2016-07-01

    To evaluate the clinical application value of internal iliac artery balloon occlusion in pernicious placenta previa. We retrospectively reviewed the medical records of the patients of pernicious placenta previa in a single center from Jan, 2010 to Jan, 2015. The patients were divided into two groups, internal iliac artery balloon occlusion group and the control group without endovascular intervention. Blood loss in operation, volume of transfused blood products, caesarean hysterectomy, operating time, hospital days after operation and postoperative morbidity were compared between the two groups. The balloon occlusion group had significantly less blood loss, the volume of transfused blood products, caesarean hysterectomy, hospital day after operation than the control group had. There was no statistical difference in operating time, intensive care units (ICU), hypotension, infection, hypoxemia, bladder injury, bowel obstruction, neonatal asphyxia between the two groups. The balloon occlusion group had significantly higher rate in coagulopathy, hypoalbuminemia, electrolyte imbalance. Among the patients whose uterus were preserved, the blood loss was not significantly difference between the two groups. Among the patients with the complication of placenta accreta, caesarean hysterectomy was less in balloon group, and blood loss between the two groups was not significantly different. Among the patients without placenta accrete, the blood loss was less in balloon group, and caesarean hysterectomy between the two groups was not significantly different. The risk of hysterectomy in balloon group was related to placenta accreta, uterine arteries engorgement, placental invasive serosa, taking placenta by hand, placental invasive bladder, barrel-shaped thickening of lower uterine segment, unable to remove placenta. Internal iliac artery balloon occlusion is an effective treatment for pernicious placenta previa.

  12. Bipolar versus balloon endometrial ablation in the office: a randomized controlled trial.

    PubMed

    Penninx, Josien P M; Herman, Malou C; Kruitwagen, Roy F P M; Ter Haar, Annette J F; Mol, Ben W; Bongers, Marlies Y

    2016-01-01

    To compare the effectiveness of bipolar radiofrequency (Novasure®) ablation and balloon endometrial ablation (Thermablate®). We performed a multi-center double blind, randomized controlled trial in three hospitals in The Netherlands. Women with heavy menstrual bleeding were randomly allocated to bipolar or balloon endometrial ablation, performed in the office, using a paracervical block. The primary outcome was amenorrhea. Secondary outcome measures were pain, satisfaction, quality of life and reintervention. 104 women were randomized into the bipolar (52) and balloon (52) groups. After 12 months amenorrhea rates were 56% (29/52) in the bipolar group and 23% (12/52) in the balloon group (relative risk (RR) 0.6, 95% confidence interval (CI) 0.4-0.8). The mean visual analog pain score of the total procedure was 7.1 in the bipolar group and 7.4 in the balloon group (P<.577). 87% (45/52) of the patients in the bipolar group were satisfied with the result of the treatment versus 69% (36/52) in the balloon group (RR 0.44, 95% CI 0.2-0.97). The reintervention rates were 5/52 (10%) in the bipolar group and 6/52 (12%) in the balloon group (RR 1.02, 95% CI 0.9-1.2). Quality of life (Shaw score) improved over time (P<.001) and was significantly higher in the bipolar group at 12 months follow-up (P=.025). In the treatment of heavy menstrual bleeding, bipolar radiofrequency endometrial ablation is superior to balloon endometrial ablation as an office procedure in amenorrhea rate, patient satisfaction and quality of life. Copyright © 2015. Published by Elsevier Ireland Ltd.

  13. Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon.

    PubMed

    Parsi, Mansour A; Stevens, Tyler; Vargo, John J

    2012-08-14

    To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation.

  14. Use of mechanical devices for distal hemoperfusion during balloon catheter coronary angioplasty.

    PubMed

    Heibig, J; Angelini, P; Leachman, D R; Beall, M M; Beall, A C

    1988-01-01

    Previous attempts to protect the dependent myocardium during balloon catheter coronary angioplasty in animals and humans have had generally unsatisfactory results. This paper summarizes the authors' experience in investigating commercially available mechanical pumps for distal coronary hemoperfusion during balloon angioplasty. Both roller and piston pumps can attain adequate distal perfusion without significant side effects in the majority of patients. Our goal was to suppress angina for at least 5 min to prolong balloon inflation in awake patients. Minor T-wave changes without concomitant angina pectoris can be expected when the distal coronary bed is perfused with hypothermic blood. Side branch occlusion by the inflated balloon prevents effective protection of the corresponding part of the dependent myocardium during distal hemoperfusion, which may result in persistent angina and ST-T changes uncorrected by increasing the hemoperfusion rate. Distal coronary diffuse spasm, rare and transient, was the only immediate complication of this procedure. It is suggested that intense local wall stimulation could occur with a higher flow rate (jet effect). Improved balloon catheter pressure/flow characteristics and on-line continuous mechanical pumps should soon make distal coronary hemoperfusion through balloon catheters an accepted clinical technique.

  15. [Effect of hot-air balloon crossings on animals in the open air].

    PubMed

    Stephan, E

    1997-02-01

    Since the middle of the eighties owners of animals increasingly claimed compensation from balloon pilots. They asserted, that their animals got restless due to strange optical and acoustical stimuli caused by low altitude crossing of hot-air balloons and were damaged while trying to get out of the way or to escape. Very low altitude "Contour crossing" of hot-air balloons, mainly forming the basis of complaints, is only left possible in a limited degree in Germany since the air traffic regulations were changed to a higher minimum safety altitude (Air Traffic Act, LuftVO, version of March 21, 1995) and the violating balloon pilot may be disciplined. The paper is dealing with the principle of hot-air ballooning, with the feasibility of the pilot to avoid and restrict damages, with the possibilities to assign damages to a potential cause and with the legal basis.

  16. Antibody index and specific antibody quotient in horses after intragastric administration of Sarcocystis neurona sporocysts.

    PubMed

    Heskett, Katherine A; Mackay, Robert J

    2008-03-01

    To investigate the use of a specific antibody index (AI) that relates Sarcocystis neurona-specific IgG quotient (Q(SN)) to total IgG quotient (Q(IgG)) for the detection of the anti-S neurona antibody fraction of CNS origin in CSF samples obtained from horses after intragastric administration of S neurona sporocysts. 18 adult horses. 14 horses underwent intragastric inoculation (day 0) with S neurona sporocysts, and 4 horses remained unchallenged; blood and CSF samples were collected on days - 1 and 84. For purposes of another study, some challenged horses received intermittent administration of ponazuril (20 mg/kg, PO). Sarcocystis neurona-specific IgG concentrations in CSF (SN(CSF)) and plasma (SN(plasma)) were measured via a direct ELISA involving merozoite lysate antigen and reported as ELISA units (EUs; arbitrary units based on a nominal titer for undiluted immune plasma of 100,000 EUs/mL). Total IgG concentrations in CSF (IgG(CSF)) and plasma (IgG(plasma)) were quantified via a sandwich ELISA and a radial immunodiffusion assay, respectively; Q(SN), Q(IgG), and AI were calculated. Following sporocyst challenge, mean +/- SEM SN(CSF) and SN(plasma) increased significantly (from 8.8 +/- 1.0 EUs/mL to 270.0 +/- 112.7 EUs/mL and from 1,737 +/- 245 EUs/mL to 43,169 +/- 13,770 EUs/mL, respectively). Challenge did not affect total IgG concentration, Q(SN), Q(IgG), or AI. S neurona-specific IgG detected in CSF samples from sporocyst-challenged horses appeared to be extraneural in origin; thus, this experimental challenge may not reliably result in CNS infection. Calculation of a specific AI may have application to the diagnosis of S neurona-associated myeloencephalitis in horses.

  17. Intragastric preloads of l-tryptophan reduce ingestive behavior via oxytocinergic neural mechanisms in male mice.

    PubMed

    Gartner, Sarah N; Aidney, Fraser; Klockars, Anica; Prosser, Colin; Carpenter, Elizabeth A; Isgrove, Kiriana; Levine, Allen S; Olszewski, Pawel K

    2018-06-01

    Human and laboratory animal studies suggest that dietary supplementation of a free essential amino acid, l-tryptophan (TRP), reduces food intake. It is unclear whether an acute gastric preload of TRP decreases consumption and whether central mechanisms underlie TRP-driven hypophagia. We examined the effect of TRP administered via intragastric gavage on energy- and palatability-induced feeding in mice. We sought to identify central mechanisms through which TRP suppresses appetite. Effects of TRP on consumption of energy-dense and energy-dilute tastants were established in mice stimulated to eat by energy deprivation or palatability. A conditioned taste aversion (CTA) paradigm was used to assess whether hypophagia is unrelated to sickness. c-Fos immunohistochemistry was employed to detect TRP-induced activation of feeding-related brain sites and of oxytocin (OT) neurons, a crucial component of satiety circuits. Also, expression of OT mRNA was assessed with real-time PCR. The functional importance of OT in mediating TRP-driven hypophagia was substantiated by showing the ability of OT receptor blockade to abolish TRP-induced decrease in feeding. TRP reduced intake of energy-dense standard chow in deprived animals and energy-dense palatable chow in sated mice. Anorexigenic doses of TRP did not cause a CTA. TRP failed to affect intake of palatable yet calorie-dilute or noncaloric solutions (10% sucrose, 4.1% Intralipid or 0.1% saccharin) even for TRP doses that decreased water intake in thirsty mice. Fos analysis revealed that TRP increases activation of several key feeding-related brain areas, especially in the brain stem and hypothalamus. TRP activated hypothalamic OT neurons and increased OT mRNA levels, whereas pretreatment with an OT antagonist abolished TRP-driven hypophagia. We conclude that intragastric TRP decreases food and water intake, and TRP-induced hypophagia is partially mediated via central circuits that encompass OT. Copyright © 2018 Elsevier Ltd. All

  18. 'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.

    PubMed

    Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao

    2015-04-01

    The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.

  19. Modeling the ascent of sounding balloons: derivation of the vertical air motion

    NASA Astrophysics Data System (ADS)

    Gallice, A.; Wienhold, F. G.; Hoyle, C. R.; Immler, F.; Peter, T.

    2011-10-01

    A new model to describe the ascent of sounding balloons in the troposphere and lower stratosphere (up to ∼30-35 km altitude) is presented. Contrary to previous models, detailed account is taken of both the variation of the drag coefficient with altitude and the heat imbalance between the balloon and the atmosphere. To compensate for the lack of data on the drag coefficient of sounding balloons, a reference curve for the relationship between drag coefficient and Reynolds number is derived from a dataset of flights launched during the Lindenberg Upper Air Methods Intercomparisons (LUAMI) campaign. The transfer of heat from the surrounding air into the balloon is accounted for by solving the radial heat diffusion equation inside the balloon. In its present state, the model does not account for solar radiation, i.e. it is only able to describe the ascent of balloons during the night. It could however be adapted to also represent daytime soundings, with solar radiation modeled as a diffusive process. The potential applications of the model include the forecast of the trajectory of sounding balloons, which can be used to increase the accuracy of the match technique, and the derivation of the air vertical velocity. The latter is obtained by subtracting the ascent rate of the balloon in still air calculated by the model from the actual ascent rate. This technique is shown to provide an approximation for the vertical air motion with an uncertainty error of 0.5 m s-1 in the troposphere and 0.2 m s-1 in the stratosphere. An example of extraction of the air vertical velocity is provided in this paper. We show that the air vertical velocities derived from the balloon soundings in this paper are in general agreement with small-scale atmospheric velocity fluctuations related to gravity waves, mechanical turbulence, or other small-scale air motions measured during the SUCCESS campaign (Subsonic Aircraft: Contrail and Cloud Effects Special Study) in the orographically

  20. The effect of a hay grid feeder on feed consumption and measurement of the gastric pH using an intragastric electrode device in horses: a preliminary report.

    PubMed

    Aristizabal, F; Nieto, J; Yamout, S; Snyder, J

    2014-07-01

    Obesity and gastric ulceration are highly prevalent in horses. Management modifications for preventing squamous gastric ulceration include frequent feeding and free access to pasture; however, these practices may predispose horses to obesity. To compare the percentage of hay consumed, intragastric pH and horse activity between feeding from the ground and a hay grid feeder. Crossover experimental study. A pH electrode was inserted into the stomach to record the intragastric pH for 48 h. Horses received 1% of their body weight in grass hay twice a day. Horses were assigned to be fed from the ground or a commercial hay grid feeder for 24 h and then switched to the opposite protocol for an additional 24 h. Horses were continuously video-recorded and the percentage of time spent eating or drinking, walking or standing, and lying down were calculated. Two point data were compared by paired t test and pH over time was compared by repeated measures ANOVA. Horses consumed significantly greater amounts of grass hay when fed on the ground compared with a hay grid feeder (n = 9; P<0.001). There were no significant differences between the groups for mean intragastric pH values (n = 6; P = 0.97), mean intragastric pH over time (n = 6; P = 0.45) the length of time the pH was below 4.0 (n = 6; P = 0.54), and the percentage of time horses spent eating or drinking (n = 9; P = 0.52), walking or standing (n = 9; P = 0.3), or lying down (n = 9; P = 0.4). Within each group horses spent more time eating during the day compared with the night (n = 9; hay grid feeder P = 0.003; ground feeding P = 0.007). The hay grid feeder studied may be used to reduce the amount of hay ingested by horses without reducing the time horses spend eating. © 2013 EVJ Ltd.

  1. High Altitude Balloons as a Platform for Space Radiation Belt Science

    NASA Astrophysics Data System (ADS)

    Mazzino, L.; Buttenschoen, A.; Farr, Q.; Hodgson, C.; Johnson, W.; Mann, I. R.; Rae, J.; University of Alberta High Altitude Balloons (UA-HAB)

    2011-12-01

    The goals of the University of Alberta High Altitude Balloons Program (UA-HAB) are to i) use low cost balloons to address space radiation science, and ii) to utilise the excitement of "space mission" involvement to promote and facilitate the recruitment of undergraduate and graduate students in physics, engineering, and atmospheric sciences to pursue careers in space science and engineering. The University of Alberta High Altitude Balloons (UA-HAB) is a unique opportunity for University of Alberta students (undergraduate and graduate) to engage in the hands-on design, development, build, test and flight of a payload to operate on a high altitude balloon at around 30km altitude. The program development, including formal design and acceptance tests, reports and reviews, mirror those required in the development of an orbital satellite mission. This enables the students to gain a unique insight into how space missions are flown. UA-HAB is a one and half year program that offers a gateway into a high-altitude balloon mission through hands on experience, and builds skills for students who may be attracted to participate in future space missions in their careers. This early education will provide students with the experience necessary to better assess opportunities for pursuing a career in space science. Balloons offer a low-cost alternative to other suborbital platforms which can be used to address radiation belt science goals. In particular, the participants of this program have written grant proposal to secure funds for this project, have launched several 'weather balloon missions', and have designed, built, tested, and launched their particle detector called "Maple Leaf Particle Detector". This detector was focussed on monitoring cosmic rays and space radiation using shielded Geiger tubes, and was flown as one of the payloads from the institutions participating in the High Altitude Student Platform (HASP), organized by the Louisiana State University and the Louisiana

  2. Integrating BalloonSAT and Atmospheric Dynamic Concepts into the Secondary Classroom

    NASA Astrophysics Data System (ADS)

    Fong, B. N.; Kennon, J. T.; Roberts, E.

    2016-05-01

    Arkansas BalloonSAT is an educational outreach and scientific research program that is part of Arkansas State University in Jonesboro, AR. The following is a unit of instruction to incorporate BalloonSAT measurements into secondary science classes. Students interpret graphs and identify several atmospheric trends and properties of a typical balloon flight. Students engage critical thinking skills in developing and answering their own questions relevant to the BalloonSAT program. Prerequisite concepts students should know are how to interpret graphs and unit conversions. Students should have a basic understanding of gravity, units of temperature and distance, and error in measurements. The unit is designed for one week after end-of-course exams and before the end of school. The unit may take two to five 50-minute periods, depending on how many activities are completed.

  3. Long duration balloon flights in the middle stratosphere

    NASA Astrophysics Data System (ADS)

    Malaterre, P.

    1993-02-01

    Research and development performed by the French Space Agency (CNES) over the past 10 years has given the scientific community the Infrared Montgolfiere, a balloon capable of lifting 50-kg payloads into the stratosphere for periods of several weeks. The Infrared Montgolfiere is a hot air balloon that captures infrared radiation using the earth as a heat source. Thirty flights have been launched so far, some lasting more than sixty days and circling the globe twice.

  4. Solar cell calibration facility validation of balloon flight data: A comparison of shuttle and balloon flight results

    NASA Technical Reports Server (NTRS)

    Anspaugh, B. E.; Downing, R. G.; Sidwell, L. B.

    1985-01-01

    The Solar Cell Calibration Facility (SCCF) experiment was designed and built to evaluate the effect of the Earth's upper atmosphere on the calibration of solar cell standards. During execution of the experiment, a collection of carefully selected solar cells was flown on the shuttle, and reflown on a high-altitude balloon, then their outputs were compared. After correction to standard temperature and intensity values of 28 C and an Earth-Sun distance of 1 AU, the solar cell outputs during the two flights were found to be identical. The conclusion is therefore that the high-altitude balloon flights are very good vehicles for calibrating solar cells for use as space flight reference standards.

  5. Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, Poul Erik; Kjeldsen, Anette D.

    2008-05-15

    Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available anymore, but use of these balloons for embolization of pulmonary arteriovenousmore » malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing the pulmonary arteriovenous malformation. No case of recanalization has been discovered, and these results seem to justify a reduced number of controls of these balloon-embolized malformations.« less

  6. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    BARREL team members lift up the instrument box below an inflated BARREL balloon to help with launch. Credit: NASA/Goddard/Francois Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy.NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission.Follow us on TwitterLike us on FacebookFind us on Instagram

  7. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    A team member from South African research station, SANAE IV, helps unwrap the balloon from its protective yellow plastic cover just prior to inflation. Credit: NASA/Goddard/BARREL/Nicky Knox Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  8. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2017-12-08

    The Halley station team members assisted the BARREL team with the launches. Here, one gives the thumbs up to start inflating a BARREL balloon. Credit: NASA/Goddard/BARREL/M. Krzysztofowicz Read more: www.nasa.gov/content/nasas-barrel-returns-successful-from... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  9. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    Getting fuller! A BARREL balloon is filled with helium during the 2013-2014 mission campaign in Antarctica. Credit: NASA/Goddard/BARREL Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy.NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission.Follow us on TwitterLike us on FacebookFind us on Instagram

  10. Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloon.

    PubMed

    Secco, Gioel Gabrio; Ghione, Matteo; Mattesini, Alessio; Dall'Ara, Gianni; Ghilencea, Liviu; Kilickesmez, Kadriye; De Luca, Giuseppe; Fattori, Rossella; Parisi, Rosario; Marino, Paolo Nicola; Lupi, Alessandro; Foin, Nicolas; Di Mario, Carlo

    2016-06-20

    Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.

  11. Simultaneous electric-field measurements on nearby balloons.

    NASA Technical Reports Server (NTRS)

    Mozer, F. S.

    1972-01-01

    Electric-field payloads were flown simultaneously on two balloons from Great Whale River, Canada, on September 21, 1971, to provide data at two points in the upper atmosphere that differed in altitude by more than one atmospheric density scale height and in horizontal position by 30-140 km. The altitude dependences in the two sets of data prove conclusively that the vertical electric field at balloon altitudes stems from fair-weather atmospheric electricity sources and that the horizontal fields are mapped down ionospheric fields, since the weather-associated horizontal fields were smaller than 2 mV/m.

  12. Long Duration Balloon flights development. (Italian Space Agency)

    NASA Astrophysics Data System (ADS)

    Peterzen, S.; Masi, S.; Dragoy, P.; Ibba, R.; Spoto, D.

    Stratospheric balloons are rapidly becoming the vehicle of choice for near space investigations and earth observations by a variety of science disciplines. With the ever increasing research into climatic change, earth observations, near space research and commercial component testing, instruments suspended from stratospheric balloons offer the science team a unique, stable and reusable platform that can circle the Earth in the polar region or equatorial zone for thirty days or more. The Italian Space Agency (ASI) in collaboration with Andoya Rocket Range (Andenes, Norway) has opened access in the far northern latitudes above 78º N from Longyearbyen, Svalbard. In 2006 the first Italian UltraLite Long Duration Balloon was launched from Baia Terra Nova, Mario Zuchelli station in Antarctica and now ASI is setting up for the their first equatorial stratospheric launch from their satellite receiving station and rocket launch site in Malindi, Kenya. For the equatorial missions we have analysed the statistical properties of trajectories considering the biennial oscillation and the seasonal effects of the stratospheric winds. Maintaining these launch sites offer the science community 3 point world coverage for heavy lift balloons as well as the rapidly deployed Ultra-light payloads and TM systems ASI developed to use for test platforms, micro experiments, as well as a comprehensive student pilot program. This paper discusses the development of the launch facilities and international LDB development.

  13. Modeling the ascent of sounding balloons: derivation of the vertical air motion

    NASA Astrophysics Data System (ADS)

    Gallice, A.; Wienhold, F. G.; Hoyle, C. R.; Immler, F.; Peter, T.

    2011-06-01

    A new model to describe the ascent of sounding balloons in the troposphere and lower stratosphere (up to ~30-35 km altitude) is presented. Contrary to previous models, detailed account is taken of both the variation of the drag coefficient with altitude and the heat imbalance between the balloon and the atmosphere. To compensate for the lack of data on the drag coefficient of sounding balloons, a reference curve for the relationship between drag coefficient and Reynolds number is derived from a dataset of flights launched during the Lindenberg Upper Air Methods Intercomparisons (LUAMI) campaign. The transfer of heat from the surrounding air into the balloon is accounted for by solving the radial heat diffusion equation inside the balloon. The potential applications of the model include the forecast of the trajectory of sounding balloons, which can be used to increase the accuracy of the match technique, and the derivation of the air vertical velocity. The latter is obtained by subtracting the ascent rate of the balloon in still air calculated by the model from the actual ascent rate. This technique is shown to provide an approximation for the vertical air motion with an uncertainty error of 0.5 m s-1 in the troposphere and 0.2 m s-1 in the stratosphere. An example of extraction of the air vertical velocity is provided in this paper. We show that the air vertical velocities derived from the balloon soundings in this paper are in general agreement with small-scale atmospheric velocity fluctuations related to gravity waves, mechanical turbulence, or other small-scale air motions measured during the SUCCESS campaign (Subsonic Aircraft: Contrail and Cloud Effects Special Study) in the orographically unperturbed mid-latitude middle troposphere.

  14. Onyx embolization using dual-lumen balloon catheter: initial experience and technical note.

    PubMed

    Paramasivam, Srinivasan; Niimi, Yasunari; Fifi, Johanna; Berenstein, Alejandro

    2013-10-01

    Onyx as an embolization agent for the management of vascular malformation is well established. We report our initial experience with dimethyl-sulphoxide (DMSO) compatible double lumen balloon catheters used for Onyx embolization. Between December 2011 and March 2013, we treated 22 patients aged between 1.5 to 70years with two types of DMSO compatible dual-lumen balloon catheters (Scepter C and Ascent) to treat dural arteriovenous fistulas, brain arteriovenous malformation (AVM) with dural feeders, mandibular, facial, lingual, vertebral and paravertebral AVMs. The catheter has good navigability, compliant balloon on inflation formed a "plug" that has more resistance than Onyx plug enhancing better penetration. During injection, the balloon remained stable without spontaneous deflation or rupture and withstood the pressure build-up well. The retrieval of the catheter in most cases took less than a minute (19/28) while in five, it was less than five minutes and in the remaining four, it was longer that includes a trapped catheter on prolonged attempted retrieval resulted in an epidural hematoma, requiring emergent surgical evacuation. The fluoroscopy time is reduced, as we do not form a proximal onyx plug, the injection time is shorter along with easy and instantaneous removal of the catheter after balloon deflation in most cases. Dual-lumen balloon catheter Onyx embolization is a safe and effective technique. Currently, an important tool to circumvent some of the shortcomings associated with Onyx embolization. The catheter has good navigability, the balloon has stability, tolerance, enhances penetrability. It is easy to retrieve the microcatheter. With the experience gained, and with more compliant balloon catheters available, this technique can be applied to cerebral vessels in near future. Copyright © 2013. Published by Elsevier Masson SAS.

  15. Balloon dilation of the eustachian tube for dilatory dysfunction: A randomized controlled trial.

    PubMed

    Poe, Dennis; Anand, Vijay; Dean, Marc; Roberts, William H; Stolovitzky, Jose Pablo; Hoffmann, Karen; Nachlas, Nathan E; Light, Joshua P; Widick, Mark H; Sugrue, John P; Elliott, C Layton; Rosenberg, Seth I; Guillory, Paul; Brown, Neil; Syms, Charles A; Hilton, Christopher W; McElveen, John T; Singh, Ameet; Weiss, Raymond L; Arriaga, Moises A; Leopold, John P

    2018-05-01

    To assess balloon dilation of the Eustachian tube with Eustachian tube balloon catheter in conjunction with medical management as treatment for Eustachian tube dilatory dysfunction. In this prospective, multicenter, randomized, controlled trial, we assigned, in a 2:1 ratio, patients age 22 years and older with Eustachian tube dilatory dysfunction refractory to medical therapy to undergo balloon dilation of the Eustachian tube with balloon catheter in conjunction with medical management or medical management alone. The primary endpoint was normalization of tympanogram at 6 weeks. Additional endpoints were normalization of Eustachian Tube Dysfunction Questionaire-7 symptom scores, positive Valsalva maneuver, mucosal inflammation, and safety. Primary efficacy results demonstrated superiority of balloon dilation of the Eustachian tube with balloon catheter + medical management compared to medical management alone. Tympanogram normalization at 6-week follow-up was observed in 51.8% (72/139) of investigational patients versus 13.9% (10/72) of controls (P < .0001). Tympanogram normalization in the treatment group was 62.2% after 24 weeks. Normalization of Eustachian Tube Dysfunction Questionaire-7 Symptom scores at 6-week follow-up was observed in 56.2% (77/137) of investigational patients versus 8.5% (6/71) controls (P < .001). The investigational group also demonstrated substantial improvement in both mucosal inflammation and Valsalva maneuver at 6-week follow-up compared to controls. No device- or procedure-related serious adverse events were reported for those who underwent balloon dilation of the Eustachian tube. This study demonstrated superiority of balloon dilation of the Eustachian tube with balloon catheter + medical management compared to medical management alone to treat Eustachian tube dilatory dysfunction in adults. 1b. Laryngoscope, 128:1200-1206, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Planetary Science with Balloon-Borne Telescopes

    NASA Technical Reports Server (NTRS)

    Kremic, Tibor; Cheng, Andy; Hibbitts, Karl; Young, Eliot

    2015-01-01

    The National Aeronautics and Space Administration (NASA) and the planetary science community have recently been exploring the potential contributions of stratospheric balloons to the planetary science field. A study that was recently concluded explored the roughly 200 or so science questions raised in the Planetary Decadal Survey report and found that about 45 of those questions are suited to stratospheric balloon based observations. In September of 2014, a stratospheric balloon mission called BOPPS (which stands for Balloon Observation Platform for Planetary Science) was flown out of Fort Sumner, New Mexico. The mission had two main objectives, first, to observe a number of planetary targets including one or more Oort cloud comets and second, to demonstrate the applicability and performance of the platform, instruments, and subsystems for making scientific measurements in support planetary science objectives. BOPPS carried two science instruments, BIRC and UVVis. BIRC is a cryogenic infrared multispectral imager which can image in the.6-5 m range using an HgCdTe detector. Narrow band filters were used to allow detection of water and CO2 emission features of the observed targets. The UVVis is an imager with the science range of 300 to 600 nm. A main feature of the UVVis instrument is the incorporation of a guide camera and a Fine Steering Mirror (FSM) system to reduce image jitter to less than 100 milliarcseconds. The BIRC instrument was used to image targets including Oort cloud comets Siding Spring and Jacques, and the dwarf planet 1 Ceres. BOPPS achieved the first ever earth based CO2 observation of a comet and the first images of water and CO2 of an Oort cloud comet (Jacques). It also made the first ever measurement of 1Ceres at 2.73 m to refine the shape of the infrared water absorption feature on that body. The UVVis instrument, mounted on its own optics bench, demonstrated the capability for image correction both from atmospheric disturbances as well as some

  17. Endovascular techniques in limb salvage: cutting, cryo, brachy, and drug-eluting balloons.

    PubMed

    Davies, Mark G; Anaya-Ayala, Javier E

    2013-04-01

    The complex pathophysiology response to injury of the lower-extremity arteries has prompted the development of several unique balloon technologies to overcome initial technical failures and short-term intimal hyperplasia. Cryoplasty alters the cellular and mechanical properties of the vessel wall during angioplasty. Cutting balloons incise the wall, preventing elastic recoil and allowing expansion of the lumen at a lower pressure, thus limiting barotrauma. Drug-eluting balloons actively transfer inhibitory compounds to the wall during the initial therapy, while brachytherapy balloons allow for localized delivery of radiation to inhibit the proliferative response seen after angioplasty. These platforms provide unique means to enhance immediate and short-term results and also reduce stent usage in the lower extremity.

  18. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    PubMed

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  19. Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon

    PubMed Central

    Parsi, Mansour A; Stevens, Tyler; Vargo, John J

    2012-01-01

    AIM: To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). METHODS: Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. RESULTS: Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. CONCLUSION: Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation. PMID:22912549

  20. Investigations of Balloon and Aeroplane Fabrics

    NASA Technical Reports Server (NTRS)

    Gibbons, Willis A; Smith, Omar H

    1917-01-01

    Report presents the experimental results of fabrics used for balloons and aeroplanes. Tensile properties, surface roughness, skin friction, flammability, permeability, and water absorption were tested for different combinations of materials.

  1. Ballooning Ideas for the Science Classroom.

    ERIC Educational Resources Information Center

    Park, John C.; Carter, Glenda S.

    1988-01-01

    Introduces three demonstrations using rubber balloons: rate of reaction, air pressure, and solubility of gases in liquids. Provides the materials, procedure, questions, further investigation, and discussion in each demonstration. (YP)

  2. Endoscopic minor papilla balloon dilation for the treatment of symptomatic pancreas divisum.

    PubMed

    Yamamoto, Natsuyo; Isayama, Hiroyuki; Sasahira, Naoki; Tsujino, Takeshi; Nakai, Yousuke; Miyabayashi, Koji; Mizuno, Suguru; Kogure, Hirofumi; Sasaki, Takashi; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2014-08-01

    A subpopulation of patients with pancreas divisum experience symptomatic events such as recurrent acute pancreatitis and chronic pancreatitis. Minor papilla sphincterotomy has been reported as being an effective treatment. The aim of this study was to evaluate the safety and efficacy of endoscopic balloon dilation for the minor papilla. Between 2000 and 2012, 16 patients were retrospectively included in this study. After endoscopic balloon dilation for the minor papilla was received, a pancreatic stent or a nasal pancreatic drainage catheter was placed for 1 week. If a stricture or obstruction was evident, it was treated with balloon dilation followed by long-term stent placement (1 year). When an outflow of pancreatic juice was disturbed by a pancreatic stone, endoscopic stone extraction was performed. Balloon dilation and stent placement were achieved and were successful in all the cases (16/16; 100%). Clinical improvement was achieved in 7 (84.7%) of the 9 patients with recurrent acute pancreatitis and in 6 (85.7%) of the 7 patients with chronic pancreatitis. Early complications were observed in 1 (6.3%) patient. Pancreatitis or bleeding related to balloon dilation was not observed. Endoscopic balloon dilation for the minor papilla is feasible for the management of symptomatic pancreas divisum.

  3. 78 FR 6838 - Certain Balloon Dissection Devices and Products Containing Same; Institution of Investigation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-31

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-865] Certain Balloon Dissection Devices... the United States after importation of certain dissection balloons and products containing the same by... importation of certain dissection balloons and products containing the same that infringe one or more of...

  4. Field-Line Localized Destabilization of Ballooning Modes in Three-Dimensional Tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willensdorfer, M.; Cote, T. B.; Hegna, C. C.

    2017-08-25

    Field-line localized ballooning modes have been observed at the edge of high confinement mode plasmas in ASDEX Upgrade with rotating 3D perturbations induced by an externally applied n ¼ 2 error field and during a moderate level of edge localized mode mitigation. The observed ballooning modes are localized to the field lines which experience one of the two zero crossings of the radial flux surface displacement during one rotation period. The localization of the ballooning modes agrees very well with the localization of the largest growth rates from infinite-n ideal ballooning stability calculations using a realistic 3D ideal magnetohydrodynamic equilibrium.more » This analysis predicts a lower stability with respect to the axisymmetric case. The primary mechanism for the local lower stability is the 3D distortion of the local magnetic shear.« less

  5. Severe Sunburn After a Hot Air Balloon Ride: A Case Report and Literature Review.

    PubMed

    Ozturk, Sinan; Karagoz, Huseyin

    2015-01-01

    Hot air balloon tours are very popular among travelers worldwide. Preventable burn injuries associated with hot air balloon rides have been reported during crashes into power lines, in propane burner explosions, and following contact with the propane burner tanks. We present a case of severe repeated sunburn, which poses another risk of preventable injury during hot air balloon rides, and briefly discuss the injury epidemiology of hot air balloon rides. © 2015 International Society of Travel Medicine.

  6. The Micro-Instrumentation Package: A Solution to Lightweight Ballooning

    NASA Astrophysics Data System (ADS)

    Juneau, Jill

    This paper discusses the design and testing of an over the horizon (OTH) light weight telemetry and termination system that can be used for small ballooning payloads. Currently, the Columbia Scientific Balloon Facility (CSBF) provides telemetry for the science payload by integrating one of two types of support packages. The type of support package integrated depends on whether the flight will stay in range of line of sight (LOS) or will exceed LOS requiring the use of over the horizon (OTH) telemetry. The weights of these systems range from 100 pounds to 350 pounds depending upon the use of redundant systems, equipment for high data rates, and batteries and/or solar panels for power requirements. These weight values are not as significant for larger payloads but can be crippling for smaller payloads. In addition, these support package systems are fairly expensive, placing a high importance on recovery. A lightweight and inexpensive telemetry system could be beneficial for various reasons. First, it would allow scientists to fly lightweight payloads on large balloons reaching even higher altitudes. Second, scientists could fly lightweight payloads on less expensive balloons such as meteorological balloons. Depending on the payload, these flights could be fairly inexpensive and even disposable. Third, a compact telemetry system on any balloon will free up more room for the science portion of the payload. In response, a compact telemetry/termination system called the Micro-Instrumentation Package (MIP) was developed. The MIP provides uplink and downlink communications, an interface to the science, housekeeping information including global positioning system (GPS) position, and relays. Instead of a power-hungry microprocessor, the MIP's central consists of a microcontroller. Microcontrollers are lower power, easily programmed, and can be purchased for less than ten dollars. For uplink and downlink telemetry, the MIP uses an LOS serial transceiver and an Iridium unit

  7. Radioactive 133-Xenon gas-filled balloon to prevent restenosis: dosimetry, efficacy, and safety considerations.

    PubMed

    Apple, Marc; Waksman, Ron; Chan, Rosanna C; Vodovotz, Yoram; Fournadjiev, Jana; Bass, Bill G

    2002-08-06

    Ionizing radiation administered intraluminally via catheter-based systems using solid beta and gamma sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (133Xe) radioactive gas-filled balloon catheter system. Overstretch balloon injury was performed in the coronary arteries of 33 domestic pigs. A novel 133Xe radioactive gas-filled balloon (3.5/45 mm) was positioned to overlap the injured segment with margins. After vacuum was obtained in the balloon catheter, approximately 2.5 cc of 133Xe gas was injected to fill the balloon. Doses of 0, 7.5, 15, and 30 Gy were delivered to a distance of 0.25 mm from the balloon surface. The dwell time ranged from 1.0 to 4.0 minutes, depending on the dose. Localization of 133Xe in the balloon was verified by a gamma camera. The average activity in a 3.5/45-mm balloon was measured at 67.7+/-12.1 mCi, and the total diffusion loss of the injected dose was 0.26% per minute of the injected dose. Bedside radiation exposure measured between 2 and 6 mR/h, and the shallow dose equivalent was calculated as 0.037 mrem per treatment. Histomorphometric analysis at 2 weeks showed inhibition of the intimal area (intimal area corrected for medial fracture length [IA/FL]) in the irradiated segments of 0.26+/-0.08 with 30 Gy, 0.07+/-0.24 with 15 Gy, and 0.12+/-0.89 with 7.5 Gy versus 0.76+/-0.08 with control P<0.001. 133Xe gas-filled balloon is feasible and effective in the reduction of neointima formation in the porcine model and safe for use in coronary arteries.

  8. The Vega balloons - A tool for studying atmosphere dynamics on Venus

    NASA Technical Reports Server (NTRS)

    Kremnev, R. S.; Selivanov, A. S.; Linkin, V. M.; Lipatov, A. N.; Tarnoruder, I. IA.; Puchkov, V. I.; Kustodiev, V. D.; Shurupov, A. A.; Ragent, B.; Preston, R. A.

    1986-01-01

    The Vega balloon experiment, designed to measure the dynamics of the Venus atmosphere, comprised the balloons themselves, their gondolas with on-board sensors and radio transmitters, and the radio telescope network on the earth. The structures and the physical parameters of the balloon probe are described, together with the instruments on the gondola, designed for the measurements of the atmospheric pressure, temperature, and vertical wind flows, and illumination, as well as possible flashes of lightning. Consideration is also given to the formatting of the information flow for the individual parameters measured.

  9. Management of postpartum hemorrhage with free-flow pressure controlled uterine balloon.

    PubMed

    Theron, Gerhard B

    2018-05-20

    The free-flow pressure controlled uterine balloon (Ellavi UBT; Sinapi biomedical, Stellenbosch, South Africa) allows the expulsion of water from the balloon to reduce volume and pressure control by adjusting the height of the supply bag above the patient. The balloon can be filled to a capacity of 750 mL without requiring expansion pressure. The device is affordable for use in lesser resourced countries with a sales price from the factory of approximately US $6. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Vagus nerve is involved in the changes in body temperature induced by intragastric administration of 1,8-cineole via TRPM8 in mice.

    PubMed

    Urata, Tomomi; Mori, Noriyuki; Fukuwatari, Tsutomu

    2017-05-22

    Transient Receptor Potential Melastatin 8 (TRPM8) is a cold receptor activated by mild cold temperature (<28°C). TRPM8 expressed in cutaneous sensory nerves is involved in cold sensation and thermoregulation. TRPM8 mRNA is detected in various tissues, including the gastrointestinal mucosa, and in the vagal afferent nerve. The relationship between vagal afferent nerve-specific expression of TRPM8 and thermoregulation remains unclear. In this study, we aimed to investigate whether TRPM8 expression in the vagal afferent nerve is involved in autonomic thermoregulation. We found that intragastric administration of 1,8-cineole, a TRPM8 agonist, increased intrascapular brown adipose tissue and colonic temperatures, and M8-B-treatment (TRPM8 antagonist) inhibited these responses. Intravenous administration of 1,8-cineole also showed similar effects. In vagotomized mice, the responses induced by intragastric administration of 1,8-cineole were attenuated. These results suggest that TRPM8 expressed in tissues apart from cutaneous sensory nerves are involved in autonomic thermoregulation response. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Exhaled nitric oxide in mylar balloons: influence of storage time, humidity and temperature.

    PubMed Central

    Bodini, Alessandro; Pijnenburg, Mariëlle W H; Boner, Atillio L; de Jongste, Johan C

    2003-01-01

    BACKGROUND: Mylar balloons are used to collect exhaled air for analysis of fractional nitric oxide concentration (FENO). AIM: We studied the effect of storage conditions on the stability of nitric oxide (NO) in mylar balloons. METHODS: Exhaled air samples and calibration gases were stored in mylar balloons at 4, 21 and 37 degrees C, with or without silica gel. NO was measured after 0, 6, 9, 24 and 48 h. Scheffe F-tests were used to compare NO values. RESULTS: NO remained stable in balloons for 9 h at all temperatures, without silica gel. NO increased between 9 and 48 h, but only with low initial FENO. Silica gel increased variability. CONCLUSIONS: FENO in mylar balloons is stable for at least 9 h. The storage temperature is not critical, but silica gel increases variability. PMID:12745548

  12. Experimental characterization and numerical modelling of polymeric film damage, constituting the stratospheric super pressurized balloons

    NASA Astrophysics Data System (ADS)

    Chaabane, Makram; Chaabane, Makram; Dalverny, Olivier; Deramecourt, Arnaud; Mistou, Sébastien

    The super-pressure balloons developed by CNES are a great challenge in scientific ballooning. Whatever the balloon type considered (spherical, pumpkin...), it is necessary to have good knowledge of the mechanical behavior of the envelope regarding to the flight level and the lifespan of the balloon. It appears during the working stages of the super pressure balloons that these last can exploded prematurely in the course of the first hours of flight. For this reason CNES and LGP are carrying out research programs about experimentations and modelling in order to predict a good stability of the balloons flight and guarantee a life time in adequacy with the technical requirement. This study deals with multilayered polymeric film damage which induce balloons failure. These experimental and numerical study aims, are a better understanding and predicting of the damage mechanisms bringing the premature explosion of balloons. The following damages phenomena have different origins. The firsts are simple and triple wrinkles owed during the process and the stocking stages of the balloons. The second damage phenomenon is associated to the creep of the polymeric film during the flight of the balloon. The first experimental results we present in this paper, concern the mechanical characterization of three different damage phenomena. The severe damage induced by the wrinkles of the film involves a significant loss of mechanical properties. In a second part the theoretical study, concerns the choice and the development of a non linear viscoelastic coupled damage behavior model in a finite element code.

  13. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    Recovery of a BARREL balloon payload after its flight. The recovery was carried out by helicopter. This area is known to be heavily crevassed so the base mountaineer is seen here with a safety rope. Credit: NASA/Goddard/BARREL/Brett Anderson Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  14. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    A BARREL balloon launches up into the sky, destined to float on the circumpolar winds around the South Pole for up to three weeks while measuring Earth's magnetic field and energetic particles from the radiation belts. Credit: NASA/Goddard/BARREL/Brett Anderson Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  15. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2017-12-08

    Members of the BARREL team in Antarctica jump up and down in what they call the Low Wind Dance as they hope for the low wind conditions needed to launch another balloon. Credit: NASA/Goddard/BARREL/Brett Anderson Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  16. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    The BARREL team at the South African research station, SANAE IV, poses next to the instrument box, which will float in the atmosphere beneath the balloon that can be seen being inflated in the background. Credit: NASA/Goddard/BARREL/Brett Anderson Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  17. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    The BARREL team at the South African research station, SANAE IV, lay out the 130-foot-long balloon on the ground to prepare for inflation. The entire set up and launch process takes three to four hours. Credit: NASA/Goddard/BARREL/Nicky Knox Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  18. Ballooning in the constant sun of the South Pole summer

    NASA Image and Video Library

    2014-04-24

    The BARREL instrument in Antarctica– prior to being encased in its protective box – destined to float beneath a giant balloon to study magnetic fields and energetic particles near the South Pole. Credit: NASA/Goddard/BARREL/Brett Anderson Read more: www.nasa.gov/content/goddard/nasas-barrel-returns-success... -- Three months, 20 balloons, and one very successful campaign. The team for NASA's BARREL – short for Balloon Array for Radiation belt Relativistic Electron Losses -- mission returned from Antarctica in March 2014. BARREL's job is to help unravel the mysterious Van Allen belts, two gigantic donuts of radiation that surround Earth, which can shrink and swell in response to incoming energy and particles from the sun and sometimes expose satellites to harsh radiation. While in Antarctica, the team launched 20 balloons carrying instruments that sense charged particles that are scattered into the atmosphere from the belts, spiraling down the magnetic fields near the South Pole. Each balloon traveled around the pole for up to three weeks. The team will coordinate the BARREL data with observations from NASA's two Van Allen Probes to better understand how occurrences in the belts relate to bursts of particles funneling down toward Earth. BARREL team members will be on hand at the USA Science and Engineering Festival in DC on April 26 and 27, 2014 for the exhibit Space Balloons: Exploring the Extremes of Space Weather. NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  19. QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALLOONING MODES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LAO, LL; SNYDER, PB; LEONARD, AW

    2002-07-01

    OAK A271 QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALLOONING MODES. Two of the major issues crucial for the design of the next generation tokamak burning plasma devices are the predictability of the edge pedestal height and control of the divertor heat load in H-mode configurations. Both of these are strongly impacted by edge localized modes (ELMs) and their size. A working model for ELMs is that they are intermediate toroidal mode number, n {approx} 5-30, peeling-ballooning modes driven by the large edge pedestal pressure gradient P{prime} and the associated large edge bootstrap current density J{sub BS}. the interplay betweenmore » P{prime} and J{sub BS} as a discharge evolves can excite peeling-ballooning modes over a wide spectrum of n. The pedestal current density plays a dual role by stabilizing the high n ballooning modes via opening access to second stability but providing free energy to drive the intermediate n peeling modes. This makes a systematic evaluation of this model particularly challenging. This paper describes recent quantitative tests of this model using experimental data from the DIII-D and the JT-60U tokamaks. These tests are made possible by recent improvements to the ELITE MHD stability code, which allow an efficient evaluation of the unstable peeling-ballooning modes, as well as by improvements to other diagnostic and analysis techniques. Some of the key testable features of this model are: (1) ELMs are triggered when the growth rates of intermediate n MHD modes become significantly large; (2) ELM sizes are related to the radial widths of the unstable modes; (3) the unstable modes have a strong ballooning character localized in the outboard bad curvature region; (4) at high collisionality, ELM size generally becomes smaller because J{sub BS} is reduced.« less

  20. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offermore » valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.« less

  1. TETHERED BALLOON MEASUREMENTS OF BIOGENIC VOCS IN THE ATMOSPHERIC BOUNDARY LAYER

    EPA Science Inventory

    Measurements of biogenic volatile organic compounds (BVOCs) have been made on a tethered balloon platform in eleven field deployments between 1985 and 1996. A series of balloon sampling packages have been developed for these campaigns and they have been used to describe boundary ...

  2. Basic development of a small balloon-mounted telemetry and its operation system by university students

    NASA Astrophysics Data System (ADS)

    Yamamoto, Masa-yuki; Kakinami, Yoshihiro; Kono, Hiroki

    In Japan, the high altitude balloon for scientific observation has been continuously launched by JAXA. The balloon has a possibility to reach 50 km altitude without tight environmental condition for onboard equipments, operating with a cost lower than sounding rockets, however, development of the large-scale scientific observation balloons by university laboratories is still difficult. Being coupled with recent improvement of semiconductor sensors, laboratory-basis balloon experiments using small weather balloons has been becoming easily in these years. Owing to an advantage of wide land fields in continental regions, the launch of such small balloons has become to be carried out many times especially in continental countries (e.g. Near Space Ventures, Inc., 2013). Although the balloon is very small as its diameter of 6 feet, excluding its extra buoyancy and the weight of the balloon itself, it is expected that about 2 kg loading capacity is remained for payloads to send it up to about 35 km altitude. However, operation of such balloons in Japan is not in general because precise prediction of a landing area of the payload is difficult, thus high-risk situation for balloon releases is remained. In this study, we aim to achieve practical engineering experiments of weather balloons in Japan to be used for scientific observation within university laboratory level as an educational context. Here we report an approach of developing many devices for a small tethered balloon currently in progress. We evaluated an accuracy of altitude measurement by using a laboratory developed altitude data logger system that consists of a GPS-module and a barometric altimeter. Diameter of the balloon was about 1.4 m. Being fulfilled with about 1440 L helium, it produced buoyancy of about 15.7 N. Taking into account of total weight including the mooring equipments, available payload mass becomes to be about 1100 g. Applying an advantage of a 3D printer of FDM (Fused Deposition Modeling

  3. Inoue Balloon Mitral Valvotomy in a 4-Year-Old Boy

    PubMed Central

    Kapoor, Aditya; Moorthy, Nagaraja; Kumar, Sudeep

    2012-01-01

    Mitral stenosis in children often has a fulminant and rapid course. Percutaneous transvenous mitral commissurotomy is accepted as the treatment of choice for mitral stenosis not only in adults, but also in younger patients who have pliable valves. Balloon mitral valvotomy has yielded good immediate and long-term results. Herein, we report successful Inoue balloon mitral valvotomy in a 4-year-old boy who had severe, symptomatic rheumatic mitral stenosis. To our knowledge, our patient is the youngest to have undergone this procedure. In addition to the case description, we discuss the features of juvenile rheumatic mitral stenosis and several technical aspects of performing the Inoue balloon mitral valvotomy procedure in children. PMID:22412242

  4. Guidelines and Suggestions for Balloon Gondola Design

    NASA Technical Reports Server (NTRS)

    Franco, Hugo

    2017-01-01

    This paper discusses the current gondola design requirements for the Columbia Scientific Balloon Facility (CSBF). The CSBF is responsible for launching and supporting balloon borne scientific instruments and has some current updated guidelines that will be discussed in this presentation. As the sophistication of Payload systems have increased in size and complexity new guidelines have been implemented in order to make these instruments stay within the acceptable launch risks. Additionally, there is a requirement to submit a proper stress analysis report that states the flight design requirements have been met. Suggestions are discussed in this presentation that establish the proper guidelines to submit these.

  5. The Ultimate Mountaintop: Astronomy Aboard Stratospheric Balloons

    NASA Technical Reports Server (NTRS)

    Wanjek, Christopher; White, Nicholas E. (Technical Monitor)

    2000-01-01

    As funding, for astronomy dwindles and the competition for observation time heats up, more astronomers may turn to balloons. Far above the Keck telescope on Hawaii's Mauna Kea, higher still than the hostile snowcapped peaks of Mt. Everest, there exists a 40-kilometer summit that will place their telescopes above 99% of the atmosphere. With the prospect of 100-day and even 1,000-day balloons, the climb to the summit is more and more tempting. Surely, given enough cash, most astronomers would opt for a lunar base or a platform beyond the Earth. Until then, many seem happy to settle for a stratospheric mountaintop.

  6. A New Type of Captive Balloon for Vertical Meteorological Observation in Urban Area

    NASA Astrophysics Data System (ADS)

    Nakamura, M.; Sakai, S.; Ono, K.

    2010-12-01

    Many meteorological observations in urban area have been made in recent years in order to investigate the mechanism of heat island. However, there are few data of cooling process in urban area. For this purpose, high density observations in both space and time are required. Generally vertical meteorological observations can be made by towers, radars, balloons. These methods are limited by urban area conditions. Among these methods, a captive balloon is mainly used to about a hundred meter from ground in a vertical meteorological observation. Small airships called kytoons or advertising balloons, for example. Conventional balloons are, however, influenced by the wind and difficult to keep the specified position. Moreover, it can be dangerous to conduct such observations in the highly build-up area. To overcome these difficulties, we are developing a new type of captive balloon. It has a wing form to gain lift and keep its position. It is also designed small to be kept in a carport. It is made of aluminum film and polyester cloth in order to attain lightweight solution. We have tried floating a balloon like NACA4424 for several years. It was difficult to keep a wing form floating up over 100 meters from ground because internal pressure was decreased by different temperature. The design is changed in this year. The balloon that has wing form NACA4415 is similar in composition to an airplane. It has a big gasbag with airship form and two wing form. It is able to keep form of a wing by high internal pressure. We will report a plan for the balloon and instances of some observations.

  7. Cutting Balloon Angioplasty in the Treatment of Short Infrapopliteal Bifurcation Disease.

    PubMed

    Iezzi, Roberto; Posa, Alessandro; Santoro, Marco; Nestola, Massimiliano; Contegiacomo, Andrea; Tinelli, Giovanni; Paolini, Alessandra; Flex, Andrea; Pitocco, Dario; Snider, Francesco; Bonomo, Lorenzo

    2015-08-01

    To evaluate the safety, feasibility, and effectiveness of cutting balloon angioplasty in the management of infrapopliteal bifurcation disease. Between November 2010 and March 2013, 23 patients (mean age 69.6±9.01 years, range 56-89; 16 men) suffering from critical limb ischemia were treated using cutting balloon angioplasty (single cutting balloon, T-shaped double cutting balloon, or double kissing cutting balloon technique) for 47 infrapopliteal artery bifurcation lesions (16 popliteal bifurcation and 9 tibioperoneal bifurcation) in 25 limbs. Follow-up consisted of clinical examination and duplex ultrasonography at 1 month and every 3 months thereafter. All treatments were technically successful. No 30-day death or adverse events needing treatment were registered. No flow-limiting dissection was observed, so no stent implantation was necessary. The mean postprocedure minimum lumen diameter and acute gain were 0.28±0.04 and 0.20±0.06 cm, respectively, with a residual stenosis of 0.04±0.02 cm. Primary and secondary patency rates were estimated as 89.3% and 93.5% at 6 months and 77.7% and 88.8% at 12 months, respectively; 1-year primary and secondary patency rates of the treated bifurcation were 74.2% and 87.0%, respectively. The survival rate estimated by Kaplan-Meier analysis was 82.5% at 1 year. Cutting balloon angioplasty seems to be a safe and effective tool in the routine treatment of short/ostial infrapopliteal bifurcation lesions, avoiding procedure-related complications, overcoming the limitations of conventional angioplasty, and improving the outcome of catheter-based therapy. © The Author(s) 2015.

  8. Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.

    PubMed

    Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y

    1994-09-01

    One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.

  9. Development of optical laser balloon and drainage from radiation vulcanized natural rubber latex

    NASA Astrophysics Data System (ADS)

    Shimamura, Yoshiyuki

    Rubber film made of radiation vulcanized natural rubber latex (RVNRL) has better transparency and lower toxicity compared with sulfur-vulcanized latex film. Optical laser balloon (optical endoscopical balloon) and drainage were developed by using RVNRL. An endoscope was equipped with a saline-filled latex rubber balloon at its tip to displace contaminating blood, bile, or gastric contents during operative portoscopy, biliary endoscopy, or upper gastrointestinal endoscopy. The transmission of Nd-Yag laser through the balloon is 98%, higher than the sulfur-vulcanized latex rubber (75%). High transparency of the drainage bag facilitated easy observation of discharged fluids without detaching the bag from the tube.

  10. Polymer blends for LDB applications. [Long Duration Ballooning

    NASA Technical Reports Server (NTRS)

    Lichkus, Andrew M.; Harrison, Ian R.

    1991-01-01

    A series of LCP/PE blends have been studied to determine the potential of such systems to produce a high modulus balloon film material which retains the balloon fabrication and low temperature flight advantages of the current PE films. Blown films of blends of 5 and 15 percent LCP in PE have been produced which show a 28 percent enhancement in modulus over the neat PE matrix. These results are substantially lower than anticipated and are explained in terms of the LCP reinforcement aspect ratio and fibril diameter.

  11. Microgravity experiment system utilizing a balloon

    NASA Astrophysics Data System (ADS)

    Namiki, M.; Ohta, S.; Yamagami, T.; Koma, Y.; Akiyama, H.; Hirosawa, H.; Nishimura, J.

    A system for microgravity experiments by using a stratospheric balloon has been planned and developed in ISAS since 1978. A rocket-shaped chamber mounting the experiment apparatus is released from the balloon around 30 km altitude. The microgravity duration is from the release to opening of parachute, controlled by an on-board sequential timer. Test flights were performed in 1980 and in 1981. In September 1983 the first scientific experiment, observing behaviors and brain activities of fishes in the microgravity circumstance, have been successfully carried out. The chamber is specially equipped with movie cameras and subtransmitters, and its release altitude is about 32 km. The microgravity observed inside the chamber is less than 2.9 × 10-3 G during 10 sec. Engineering aspects of the system used in the 1983 experiment are presented.

  12. Effects of supramaximal balloon dilatation pressures on adult cricoid and tracheal cartilage: A cadaveric study.

    PubMed

    Durvasula, Venkata S P B; Shalin, Sara C; Tulunay-Ugur, Ozlem E; Suen, James Y; Richter, Gresham T

    2018-06-01

    Cricoid fracture is a serious concern for balloon dilatation in airway stenosis. Furthermore, there are no studies examining tracheal rupture in balloon dilatation of stenotic segments. The aim of this study was to evaluate the effect of supramaximal pressures of balloons on the cricoid and tracheal rings. Prospective cadaveric study. Seven cadaveric laryngotracheal complexes of normal adults with intact cricothyroid membranes were acquired. Noncompliant vascular angioplasty balloons (BARD-VIDA) were used for dilatation. The subglottis and trachea were subjected to supramaximal dilatation pressures graduated to nominal burst pressure (NBP) and, if necessary, rated burst pressure (RBP). Larger-diameter balloons, starting from 18 mm size to 24 mm, were used. Dilatations were maintained for 3 minutes. The cricoid ring was disrupted by larger-diameter balloons (22 mm and 24 mm) even at lower pressures (less than NBP) in six cases. Tracheal cartilages were very distensible, and external examination after supramaximal dilatation (24 mm close to RBP) revealed no obvious cartilage fractures or trachealis tears. Histopathological examination revealed sloughing of mucosa in the areas corresponding to balloon placement, but no microfractures or disruption of the perichondrium of tracheal ring cartilages. These results indicate that the cricoid is vulnerable to injury from larger balloons even at lower dilatation pressures. The tracheal cartilages and the membranous wall of the trachea remained resilient to supramaximal dilatation and larger balloons. NA. Laryngoscope, 128:1304-1309, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Overview Of The Scientific Balloon Activity in Sweden 2014-2016

    NASA Astrophysics Data System (ADS)

    Abrahamsson, Mattias; Lockowandt, Christian; Andersson, Kent

    2016-07-01

    SSC, formerly known as Swedish Space Corporation, is a Swedish state-owned company working in several different space related fields, including scientific stratospheric balloon launches. Esrange Space Centre (Esrange in short) located in the north of Sweden is the launch facility of SSC, where both sounding rocket launches and stratospheric balloon launches are conducted. At Esrange there are also facilities for satellite communication, including one of the largest civilian satellite data reception stations in the world. Stratospheric balloons have been launched from Esrange since 1974, when the first flights were performed together with the French space agency CNES. These balloon flights have normally flown eastward either only over Sweden or into Finland. Some flights have also had permission to fly into Russia, as far as the Ural Mountains. Normal flight times are from 4 to 12 hours. These eastward flights are conducted during the winter months (September to May). Long duration flights have been flown from Esrange since 2005, when NASA flew the BLAST payload from Sweden to north Canada. The prevailing westerly wind pattern is very advantageous for trans-Atlantic flights during summer (late May to late July). The long flight times of 4-5 days are very beneficial for astronomical payloads, such as telescopes that need long observation times. Circumpolar flights of more than two weeks are possible if Russian overflight permission exists. Typical scientific balloon payload fields include atmospheric research, including research on ozone depletion, astronomical and cosmological research, and research in technical fields such as aerodynamics. Since last COSPAR a number of interesting balloon flights have been performed from Esrange. In late 2014 parachute tests for the ExoMars programme was performed by drop-test from balloons. This was followed up on in the summer of 2015 with full end-to-end dynamic stability tests of Earth re-entry capsule shapes. Several balloon

  14. Effects of intra-aortic balloon counterpulsation in a model of septic shock.

    PubMed

    Solomon, Steven B; Minneci, Peter C; Deans, Katherine J; Feng, Jing; Eichacker, Peter Q; Banks, Steven M; Danner, Robert L; Natanson, Charles; Solomon, Michael A

    2009-01-01

    Fluid refractory septic shock can develop into a hypodynamic cardiovascular state in both children and adults. Despite management of these patients with empirical inotropic therapy (with or without a vasodilator), mortality remains high. The effect of cardiovascular support using intra-aortic balloon counterpulsation was investigated in a hypodynamic, mechanically ventilated canine sepsis model in which cardiovascular and pulmonary support were titrated based on treatment protocols. Each week, three animals (n = 33, 10-12 kg) were administered intrabronchial Staphylococcus aureus challenge and then randomized to receive intra-aortic balloon counterpulsation for 68 hrs or no intra-aortic balloon counterpulsation (control). Bacterial doses were increased over the study (4-8 x 10(9) cfu/kg) to assess the effects of intra-aortic balloon counterpulsation during sepsis with increasing risk of death. Compared with lower bacterial doses (4-7 x 10(9) colony-forming units/kg), control animals challenged with the highest dose (8 x 10(9) colony-forming units/kg) had a greater risk of death (mortality rate 86% vs. 17%), with worse lung injury ([A - a]O2), and renal dysfunction (creatinine). These sicker animals required higher norepinephrine infusion rates to maintain blood pressure (and higher FIO2) and positive end-expiratory pressure levels to maintain oxygenation (p < or = 0.04 for all). In animals receiving the highest bacterial dose, intra-aortic balloon counterpulsation improved survival time (23.4 +/- 10 hrs longer; p = 0.003) and lowered norepinephrine requirements (0.43 +/- 0.17 microg/kg/min; p = 0.002) and systemic vascular resistance index (1.44 +/- 0.57 dynes/s/cm5/kg; p = 0.0001) compared with controls. Despite these beneficial effects, intra-aortic balloon counterpulsation was associated with an increase in blood urea nitrogen (p = 0.002) and creatinine (p = 0.12). In animals receiving lower doses of bacteria, intra-aortic balloon counterpulsation had no

  15. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    PubMed

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  16. Malignant Esophagogastric Junction Obstruction: Efficacy of Balloon Dilation Combined with Chemotherapy and/or Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ko, Gi-Young; Song, Ho-Young, E-mail: hysong@amc.seoul.kr; Hong, Heuk-Jin

    2003-04-15

    Purpose: To assess the efficacy of balloon dilation combined with chemotherapy and/or radiation therapy for palliation of dysphagia due to malignant esophagogastric junction strictures. Methods: Fluoroscopically guided balloon dilation was attempted in 20 patients. The causes of strictures were gastric adenocarcinoma (n = 10) and esophageal squamous cell carcinoma (n = 10). Scheduled chemotherapy and/or radiation therapy followed balloon dilation in all patients. Results: There were no technical failures or major complications. After balloon dilation, 15 (75%) patients showed improvement of dysphagia. No patient complained of reflux esophagitis during the follow-up period. Among the 15 patients, seven needed no furthermore » treatment for palliation of dysphagia until their deaths. The remaining eight patients underwent repeat balloon dilation(n = 4) or stent placement (n = 4)3-43 weeks (mean 15 weeks) after the initial balloon dilation because of recurrent dysphagia. Conclusion: Balloon dilation combined with chemotherapy and/or radiation therapy seems to be an easy and reasonably effective palliative treatment for malignant esophagogastric strictures.« less

  17. LISA: a java API for performing simulations of trajectories for all types of balloons

    NASA Astrophysics Data System (ADS)

    Conessa, Huguette

    2016-07-01

    LISA (LIbrarie de Simulation pour les Aerostats) is a java API for performing simulations of trajectories for all types of balloons (Zero Pressure Balloons, Pressurized Balloons, Infrared Montgolfier), and for all phases of flight (ascent, ceiling, descent). This library has for goals to establish a reliable repository of Balloons flight physics models, to capitalize developments and control models used in different tools. It is already used for flight physics study software in CNES, to understand and reproduce the behavior of balloons, observed during real flights. It will be used operationally for the ground segment of the STRATEOLE2 mission. It was developed with quality rules of "critical software." It is based on fundamental generic concepts, linking the simulation state variables to interchangeable calculation models. Each LISA model defines how to calculate a consistent set of state variables combining validity checks. To perform a simulation for a type of balloon and a phase of flight, it is necessary to select or create a macro-model that is to say, a consistent set of models to choose from among those offered by LISA, defining the behavior of the environment and the balloon. The purpose of this presentation is to introduce the main concepts of LISA, and the new perspectives offered by this library.

  18. Evaluation of differentially expressed immune-related genes in intestine of Pelodiscus sinensis after intragastric challenge with lipopolysaccharide based on transcriptome analysis.

    PubMed

    Xu, Jiehao; Zhao, Jing; Li, Yiqun; Zou, Yiyi; Lu, Binjie; Chen, Yuyin; Ma, Youzhi; Xu, Haisheng

    2016-09-01

    Pelodiscus sinensis is the most common turtle species that has been raised in East and Southeast Asia. However, there are still limited studies about the immune defense mechanisms in its small intestine until now. In the present research, histological analysis and transcriptome analysis was performed on the small intestine of P. sinensis after intragastric challenge with LPS to explore its mechanisms of immune responses to pathogens. The result showed the number of intraepithelial lymphocytes (IELs) and goblet cells (GCs) in its intestine increased significantly at 48 h post-challenge with LPS by intragastrical route, indicating clearly the intestinal immune response was induced. Compared with the control, a total of 748 differentially expressed genes (DEGs) were identified, including 361 up-regulated genes and 387 down-regulated genes. Based on the Gene Ontology (GO) annotation and the Kyoto Encyclopedia of Genes and Genomes (KEGG), 48 immune-related DEGs were identified, which were classified into 82 GO terms and 14 pathways. Finally, 18 DEGs, which were randomly selected, were confirmed by quantitative real-time PCR (qRT-PCR). Our results provide valuable information for further analysis of the immune defense mechanisms against pathogens in the small intestine of P. sinensis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. The NASA rocky mountain space grant high altitude research balloon project

    NASA Astrophysics Data System (ADS)

    Moore, R. G.; Espy, P.

    1994-02-01

    A group of U.S. universities, under the auspices of NASA's Space Grant College and Fellowship Program, has initiated a super-pressure balloon research project to measure ozone column density in the atmosphere above 20 kilometers, together with stratospheric circulation between 20 km and 40 km, over the continental U.S.A. Data from a balloon-borne ultraviolet spectrometer, together with time, altitude, latitude and longitude information from a Global Positioning System receiver, are recorded at ten-minute intervals during daytime hours in an on-board solid-state data logger. Coded messages are transmitted nightly from selected amateur radio ground stations to a receiver in the balloon gondola to command the transmission of packet radio bursts from the data logger to the ground stations, for relay to a central data collection and analysis facility at Utah State University. Discussions are under way with radio amateurs and members of the international scientific balloon community regarding extension of flights to cover the earth's northern hemisphere.

  20. The NASA rocky moutain space grant high altitude research balloon project

    NASA Astrophysics Data System (ADS)

    Moore, R. G.; Espy, P.

    1994-02-01

    A group of U.S. universities, under the auspices of NASA's Space Grant College and Fellowship Program, has initiated a super-pressure balloon research project to measure ozone column density in the atmosphere above 20 kilometers, together with stratospheric circulation between 20 km and 40 km, over the continental U.S.A. Data from a balloon-borne ultraviolet spectrometer, together with time, altitude, latitude and longitude information from a Global Positioning System reciever, are recorded at ten-minute intervals during daytime hours in an on-board solid-state data logger. Coded messages are transmitted nightly from selected amateur radio ground stations to a receiver in the balloon gondola to command transmission of packet radio bursts from the data logger to the ground stations, for relay to a central data collection and analysis facility at Utah State University. Discussions are under way with radio amateurs and members of the international scientific balloon community regarding extension of flights to cover the earth's northern hemisphere.

  1. Modular and Reusable Power System Design for the BRRISON Balloon Telescope

    NASA Astrophysics Data System (ADS)

    Truesdale, Nicholas A.

    High altitude balloons are emerging as low-cost alternatives to orbital satellites in the field of telescopic observation. The near-space environment of balloons allows optics to perform near their diffraction limit. In practice, this implies that a telescope similar to the Hubble Space Telescope could be flown for a cost of tens of millions as opposed to billions. While highly feasible, the design of a balloon telescope to rival Hubble is limited by funding. Until a prototype is proven and more support for balloon science is gained, projects remain limited in both hardware costs and man hours. Thus, to effectively create and support balloon payloads, engineering designs must be efficient, modular, and if possible reusable. This thesis focuses specifically on a modular power system design for the BRRISON comet-observing balloon telescope. Time- and cost-saving techniques are developed that can be used for future missions. A modular design process is achieved through the development of individual circuit elements that span a wide range of capabilities. Circuits for power conversion, switching and sensing are designed to be combined in any configuration. These include DC-DC regulators, MOSFET drivers for switching, isolated switches, current sensors and voltage sensing ADCs. Emphasis is also given to commercially available hardware. Pre-fabricated DC-DC converters and an Arduino microcontroller simplify the design process and offer proven, cost-effective performance. The design of the BRRISON power system is developed from these low-level circuits elements. A board for main power distribution supports the majority of flight electronics, and is extensible to additional hardware in future applications. An ATX computer power supply is developed, allowing the use of a commercial ATX motherboard as the flight computer. The addition of new capabilities is explored in the form of a heater control board. Finally, the power system as a whole is described, and its overall

  2. Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

    NASA Technical Reports Server (NTRS)

    Kogut, Alan; James, Bryan; Fixsen, Dale

    2013-01-01

    Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then

  3. Delineation of vagal emetic pathways: intragastric copper sulfate-induced emesis and viral tract tracing in musk shrews

    PubMed Central

    Meyers, Kelly; Lim, Audrey; Dye, Matthew; Pak, Diana; Rinaman, Linda; Yates, Bill J.

    2014-01-01

    Signals from the vestibular system, area postrema, and forebrain elicit nausea and vomiting, but gastrointestinal (GI) vagal afferent input arguably plays the most prominent role in defense against food poisoning. It is difficult to determine the contribution of GI vagal afferent input on emesis because various agents (e.g., chemotherapy) often act on multiple sensory pathways. Intragastric copper sulfate (CuSO4) potentially provides a specific vagal emetic stimulus, but its actions are not well defined in musk shrews (Suncus murinus), a primary small animal model used to study emesis. The aims of the current study were 1) to investigate the effects of subdiaphragmatic vagotomy on CuSO4-induced emesis and 2) to conduct preliminary transneuronal tracing of the GI-brain pathways in musk shrews. Vagotomy failed to inhibit the number of emetic episodes produced by optimal emetic doses of CuSO4 (60 and 120 mg/kg ig), but the effects of lower doses were dependent on an intact vagus (20 and 40 mg/kg). Vagotomy also failed to affect emesis produced by motion (1 Hz, 10 min) or nicotine administration (5 mg/kg sc). Anterograde transport of the H129 strain of herpes simplex virus-1 from the ventral stomach wall identified the following brain regions as receiving inputs from vagal afferents: the nucleus of the solitary tract, area postrema, and lateral parabrachial nucleus. These data indicate that the contribution of vagal pathways to intragastric CuSO4-induced emesis is dose dependent in musk shrews. Furthermore, the current neural tracing data suggest brain stem anatomical circuits that are activated by GI signaling in the musk shrew. PMID:24430885

  4. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    PubMed

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Isothermal pumping analysis for high-altitude tethered balloons

    PubMed Central

    Kuo, Kirsty A.; Hunt, Hugh E. M.

    2015-01-01

    High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe. PMID:26543573

  6. Isothermal pumping analysis for high-altitude tethered balloons.

    PubMed

    Kuo, Kirsty A; Hunt, Hugh E M

    2015-06-01

    High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe.

  7. A Sensitivity Analysis of fMRI Balloon Model.

    PubMed

    Zayane, Chadia; Laleg-Kirati, Taous Meriem

    2015-01-01

    Functional magnetic resonance imaging (fMRI) allows the mapping of the brain activation through measurements of the Blood Oxygenation Level Dependent (BOLD) contrast. The characterization of the pathway from the input stimulus to the output BOLD signal requires the selection of an adequate hemodynamic model and the satisfaction of some specific conditions while conducting the experiment and calibrating the model. This paper, focuses on the identifiability of the Balloon hemodynamic model. By identifiability, we mean the ability to estimate accurately the model parameters given the input and the output measurement. Previous studies of the Balloon model have somehow added knowledge either by choosing prior distributions for the parameters, freezing some of them, or looking for the solution as a projection on a natural basis of some vector space. In these studies, the identification was generally assessed using event-related paradigms. This paper justifies the reasons behind the need of adding knowledge, choosing certain paradigms, and completing the few existing identifiability studies through a global sensitivity analysis of the Balloon model in the case of blocked design experiment.

  8. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation.

    PubMed

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2013-05-31

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.

  9. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation.

    PubMed

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2014-05-01

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.

  10. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation

    PubMed Central

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2013-01-01

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery. PMID:23729720

  11. OCT evaluation of directional atherectomy compared to balloon angioplasty.

    PubMed

    Marmagkiolis, Konstantinos; Lendel, Vasili; Cilingiroglu, Mehmet

    2015-09-01

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    PubMed

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  13. NASA Scientific Balloon Team Hopes to Break Flight Duration Record with New Zealand Launch

    NASA Image and Video Library

    2017-12-08

    After years of tests and development, NASA’s Balloon Program team is on the cusp of expanding the envelope in high-altitude, heavy-lift ballooning with its super pressure balloon (SPB) technology. NASA’s scientific balloon experts are in Wanaka, New Zealand, prepping for the fourth flight of an 18.8 million-cubic-foot (532,000 cubic-meter) balloon, with the ambitious goal of achieving an ultra-long-duration flight of up to 100 days at mid-latitudes. Launch of the pumpkin-shaped, football stadium-size balloon is scheduled for sometime after April 1, 2016, from Wanaka Airport, pending final checkouts and flight readiness of the balloon and supporting systems. Once launched, the SPB, which is made from 22-acres of polyethylene film – similar to a sandwich bag, but stronger and more durable – will ascend to a nearly constant float altitude of 110,000 feet (33.5 km). The balloon will travel eastward carrying a 2,260-pound (1,025 kg) payload consisting of tracking, communications and scientific instruments. NASA expects the SPB to circumnavigate the globe once every one to three weeks, depending on wind speeds in the stratosphere. Read more: go.nasa.gov/1p56xKR NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  14. [Clinical application of self-made drainage tube with balloon for iatrogenic colonic perforation].

    PubMed

    Liu, Bing-rong; Li, Hui; Zhao, Li-xia; Song, Ji-tao; Wang, Yan-jun; Chen, Jing; Liu, Wei

    2012-07-01

    To investigate the clinical efficacy of colonic bypass drainage by self-made drainage tube with balloon for iatrogenic colonic perforation. A retrospective analysis of 8 patients with iatrogenic colonic perforations from January 2009 to March 2011 was performed. Self-made drainage tubes with balloon were placed in the bowel lumen endoscopically after perforations were closed with endoclips or endoloops under endoscope. The inflatable balloon at the front-end of the tube was fixed at the mouth side of colonic perforation to achieve continuous drainage of stool and intestinal juice. Endoscopic bypass continuous drainage by using self-made drainage tube with balloon was successfully carried out in all the 8 patients. All the perforations healed and no surgical intervention required. Bypass drainage continued for 3-10 days(mean 7.6 days). One patient received colonoscopy 3 days after the procedure, and displacement of the drainage tube was noticed requiring endoscopic adjustment. All the drainage tubes were removed uneventfully, and no ulceration or perforation occurred at balloon fixed site after removal. After follow up ranging from 12 to 36 months, no chronic fistula, adhesive obstruction, or abdominal infection occurred. Colonic bypass drainage by self-made drainage tube with balloon for iatrogenic colonic perforation is simple, feasible, safe and reliable.

  15. Recent Results and Near Term Outlook for the NASA Balloon Science Program

    NASA Astrophysics Data System (ADS)

    Jones, William Vernon

    Long-duration and conventional balloon flights in the traditional Astrophysics, Solar and Heliophysics, and Earth Science disciplines have continued in both polar and non-polar regions since the 39th COSPAR Assembly in Mysore, India. One of these established a new flight record of 55 days over Antarctica during the 2012-2013 austral season. That Super-TIGER science flight broke both the 42-day record of the CREAM science flight during the 2004-2005 season and the 54-day super pressure balloon test flight in 2008-2009. With two comets approaching the sun in 2013-2014, the Planetary Science community has shown increased interest in remote observations of comets, planets, and other objects in the Solar System. All of the above science disciplines are interested in super pressure balloon (SPB) flights, which have been under development by NASA, and which were strongly supported by the Astro2010 Decadal Study. A 532,152 m3 (18.8 MCF) SPB with a major gamma ray astrophysics payload is planned for an ultra-long duration balloon (ULDB) test flight around and from Antarctica during the upcoming 2014-2015 season. Flights for SPB qualification to support 1000 kg science instruments to 33 km altitude have proceeded in parallel with planning for options to increase the altitude for less massive instruments that require less atmospheric overburden. The nearly constant SPB volume will provide stable altitude long-duration flights at non-polar latitudes, thereby supporting a much broader range of scientific investigations. Scientific ballooning continues to complement and enable space missions, while training young scientists and systems engineers for the workforce needed to conduct future missions. Highlights of results from past balloon-borne measurements and expected results from ongoing and planned balloon-borne experiments will be presented.

  16. Application of new balloon catheters in the treatment of congenital heart defects

    PubMed Central

    Fiszer, Roland; Szkutnik, Małgorzata; Smerdziński, Sebastian; Chodór, Beata; Białkowski, Jacek

    2016-01-01

    Introduction Balloon angioplasty (BAP) and aortic or pulmonary balloon valvuloplasty (BAV, BPV) are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland) launched and developed. These catheters have not been clinically evaluated yet. Material and methods We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF), 10 BAV and 27 BAP in coarctations of the aorta (CoA) – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations), 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean), BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin). No such complication occured with Valver II. Conclusions Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses. PMID:27625686

  17. Atmospheric Balloon Swarms for Persistent In-Situ Measurements in Hurricanes

    NASA Astrophysics Data System (ADS)

    Meneghello, G.; Bewley, T.

    2015-12-01

    Real-time measurements within hurricanes are essential to improve forecasts, protect property and save lives. Current methods for obtaining in-situ data, including radar and satellite imagery as well as drop-sondes deployed from repeated aircraft flights above or even within the hurricane itself, are costly, dangerous and limited in duration or resolution. We demonstrate how a swarm of inexpensive, buoyancy-controlled, sensor-laden balloons can be deployed from altitude or from sea-level within a hurricane flow field, and coordinated autonomously in an energetically-efficient fashion to persistently and continuously monitor relevant properties (pressure, humidity, temperature, windspeed) of a hurricane for days at a time. Rather than fighting the gale-force winds in the storm, the strong, predictable stratification of these winds is leveraged to disperse the balloons into a favorable, time-evolving distribution and to follow the hurricane track as it moves. Certain target orbits of interest in the hurricane can be continuously sampled by some balloons, while other balloons make continuous sweeps between the eye and the spiral rain bands. We expect the acquired data to complement current measurement methods and to be instrumental in improving the numerical models' forecast skills.

  18. Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshimatsu, Rika; Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp; Ishikawa, Masaki

    2016-06-15

    PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumormore » enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.« less

  19. Sizing of patent ductus arteriosus in adults for transcatheter closure using the balloon pull-through technique.

    PubMed

    Shafi, Nabil A; Singh, Gagan D; Smith, Thomas W; Rogers, Jason H

    2018-05-01

    To describe a novel balloon sizing technique used during adult transcatheter patent ductus arteriosus (PDA) closure. In addition, to determine the clinical and procedural outcomes in six patients who underwent PDA balloon sizing with subsequent deployment of a PDA occluder device. Transcatheter PDA closure in adults has excellent safety and procedural outcomes. However, PDA sizing in adults can be challenging due to variable defect size, high flow state, or anatomical complexity. We describe a series of six cases where the balloon- pull through technique was successfully performed for PDA sizing prior to transcatheter closure. Consecutive adult patients undergoing adult PDA closure at our institution were studied retrospectively. A partially inflated sizing balloon was pulled through the defect from the aorta into the pulmonary artery and the balloon waist diameter was measured. Procedural success and clinical outcomes were obtained. Six adult patients underwent successful balloon pull-through technique for PDA sizing during transcatheter PDA closure, since conventional angiography often gave suboptimal opacification of the defect. All PDAs were treated with closure devices based on balloon PDA sizing with complete closure and no complications. In three patients that underwent preprocedure computed tomography, the balloon size matched the CT derived measurements. The balloon pull-through technique for PDA sizing is a safe and accurate sizing modality in adults undergoing transcatheter PDA closure. © 2017 Wiley Periodicals, Inc.

  20. Complications of retrograde balloon cautery endopyelotomy.

    PubMed

    Schwartz, B F; Stoller, M L

    1999-11-01

    Adult ureteropelvic junction obstruction is increasingly managed with endoscopic techniques. Retrograde balloon cautery endopyelotomy is quick, requires minimal hospital stay and allows most patients a rapid return to work. The complication rate of retrograde balloon cautery endopyelotomy ranges from 13 to 34%, with vascular injury in 0 to 16% of patients. We report 5 uncommon complications, including 4 vascular injuries, that clinicians should be familiar with when using this technique. We reviewed 52 retrograde endoscopic endopyelotomy procedures performed during a 5-year period. There were 5 uncommon complications. Accessory lower pole renal artery injuries occurred in 3 patients, 1 of whom presented 12 days after endopyelotomy. Embolization was successfully performed in all 3 cases and none had subsequent hypertension. In 1 case a right ovarian vein laceration was not evident on preoperative or postoperative angiography. Emergency post-embolization abdominal exploration revealed a 2 mm. injury to the right ovarian vein before entering the right renal vein close to the ureteropelvic junction incision. Nephrectomy and ovarian vein ligature were curative. In 1 case the electrocautery wire broke intracorporeally after firing, resulting in a bobby pin-like configuration. Successful removal was accomplished by twisting the catheter and wrapping the wire around the tip, enabling atraumatic removal. Retrograde balloon cautery endopyelotomy is an emerging technology with potential adverse outcomes. The complications we noted are complex and potentially life threatening. Awareness of these complications may help avoid poor outcomes and expedite appropriate treatment.

  1. Sonic Thermometer for High-Altitude Balloons

    NASA Technical Reports Server (NTRS)

    Bognar, John

    2012-01-01

    The sonic thermometer is a specialized application of well-known sonic anemometer technology. Adaptations have been made to the circuit, including the addition of supporting sensors, which enable its use in the high-altitude environment and in non-air gas mixtures. There is a need to measure gas temperatures inside and outside of superpressure balloons that are flown at high altitudes. These measurements will allow the performance of the balloon to be modeled more accurately, leading to better flight performance. Small thermistors (solid-state temperature sensors) have been used for this general purpose, and for temperature measurements on radiosondes. A disadvantage to thermistors and other physical (as distinct from sonic) temperature sensors is that they are subject to solar heating errors when they are exposed to the Sun, and this leads to issues with their use in a very high-altitude environment

  2. [Characteristics of Crohn's disease under 
double balloon enteroscopy].

    PubMed

    Jia, Jia; Liu, Rui; Liu, Xiangjie; Shen, Shourong; Guo, Qin

    2018-05-28

    To observe ulcer characteristics of Crohn's disease under double balloon enteroscopy, and to evaluate the correlation between endoscopic severity and clinical manifestations.
 Methods: A prospective, observational study from July 2015 to December 2016 in the Third Xiangya Hospital, Central South University, we selected 45 patients with positive double-balloon enteroscopy (DBE) and confirmed Crohn's disease. Two digestive internal physician observed the ulcer characteristics of Crohn's disease under double balloon enteroscopy, and gave a simple endoscopic score for CD (SES-CD). We analyzed the correlation between SES-CD and Crohn's disease activity index (CDAI).
 Results: DBE indicated 24 patient ulcers (53.33%) locating at the end of the ileum, 5 (11.11%) locating at ileocolon, 16 (35.56%) locating at upper gatrointestinal tract and they did not affect the end of the ileum. Among them, 8 cases (17.78%) affected only jejunum. Thirty-two patients with longitudinal ulcers in Crohn's disease, accounting for 71.11%. There was no correlation between SES-CD score and CDAI score (r=0.237, P=0.136).
 Conclusion: The ulcerative appearance in Crohn's disease were diverse under double balloon enteroscopy. Crohn's disease could only affect the upper gastrointestinal tract or jejunum. The unwounded ileum and ileocecal valve couldn't be a sign to exclude Crohn's disease. CDAI score couldn't fully assess the prognosis of Crohn's disease.

  3. Middle Atmosphere Program. Handbook for MAP. Volume 15: Balloon techniques

    NASA Technical Reports Server (NTRS)

    Murcray, D. G. (Editor)

    1985-01-01

    Some techniques employed by investigators using balloons to obtain data on the properties of the middle atmosphere are discussed. Much effort has gone into developing instruments which could be used on small balloons to measure temperature and variable species. These efforts are discussed. Remote sensing techniques used to obtain data on atmospheric composition are described. Measurement of stratospheric ions and stratospheric aerosols are also discussed.

  4. Intragastric pressure during food intake: a physiological and minimally invasive method to assess gastric accommodation.

    PubMed

    Janssen, P; Verschueren, S; Ly, H Giao; Vos, R; Van Oudenhove, L; Tack, J

    2011-04-01

    The stomach relaxes upon food intake and thereby provides a reservoir while keeping the intragastric pressure (IGP) low. We set out to determine whether we could use IGP as a measurement for stomach accommodation during food intake. In fasted healthy volunteers (n = 7-17) a manometer and an infusion catheter were positioned in the proximal stomach. After a stabilization period a nutrient drink was intragastrically infused at 15, 30 and 60 mL min(-1). To investigate the effect of impaired accommodation the effect of N(G)-monomethyl-L-arginine (L-NMMA) was examined. The volunteers scored satiation until maximum, when the experiment ended. The IGP was presented as a change from baseline (mean ± SEM) and compared with repeated measures anova. Independent on the ingestion speed, the IGP decreased initially and gradually increased thereafter. Volunteers scored maximal satiation after 699 ± 62, 809 ± 90 and 997 ± 120 mL nutrient drink infused (15, 30 and 60 mL min(-1) respectively; P < 0.01). Maximum IGP decrease was 3.4 ± 0.5 mmHg after 205 ± 28 mL, 5.1 ± 0.7 mmHg after 212 ± 46 mL, and 5.2 ± 0.7 mmHg after 296 ± 28 mL infused volume [15, 30 and 60 mL min(-1) respectively; not significant (ns)]. Post hoc analysis showed significant correlations between IGP and satiation score increase. During L-NMMA infusion IGP was significantly increased while subjects drank significantly less (816 ± 91 vs 1032 ± 71 mL; P < 0.005). Interestingly, the correlation between IGP increase and satiation score increase did not differ after L-NMMA treatment. The IGP during nutrient drink ingestion provides a minimally invasive alternative to the barostat for the assessment of gastric accommodation. These findings furthermore indicate that IGP is a major determinant of satiation. © 2011 Blackwell Publishing Ltd.

  5. A Spreadsheet Simulation Tool for Terrestrial and Planetary Balloon Design

    NASA Technical Reports Server (NTRS)

    Raquea, Steven M.

    1999-01-01

    During the early stages of new balloon design and development, it is necessary to conduct many trade studies. These trade studies are required to determine the design space, and aid significantly in determining overall feasibility. Numerous point designs then need to be generated as details of payloads, materials, mission, and manufacturing are determined. To accomplish these numerous designs, transient models are both unnecessary and time intensive. A steady state model that uses appropriate design inputs to generate system-level descriptive parameters can be very flexible and fast. Just such a steady state model has been developed and has been used during both the MABS 2001 Mars balloon study and the Ultra Long Duration Balloon Project. Using Microsoft Excel's built-in iteration routine, a model was built. Separate sheets were used for performance, structural design, materials, and thermal analysis as well as input and output sheets. As can be seen from figure 1, the model takes basic performance requirements, weight estimates, design parameters, and environmental conditions and generates a system level balloon design. Figure 2 shows a sample output of the model. By changing the inputs and a few of the equations in the model, balloons on earth or other planets can be modeled. There are currently several variations of the model for terrestrial and Mars balloons, as well there are versions of the model that perform crude material design based on strength and weight requirements. To perform trade studies, the Visual Basic language built into Excel was used to create an automated matrix of designs. This trade study module allows a three dimensional trade surface to be generated by using a series of values for any two design variables. Once the fixed and variable inputs are defined, the model automatically steps through the input matrix and fills a spreadsheet with the resulting point designs. The proposed paper will describe the model in detail, including current

  6. Balloon-borne video cassette recorders for digital data storage

    NASA Technical Reports Server (NTRS)

    Althouse, W. E.; Cook, W. R.

    1985-01-01

    A high speed, high capacity digital data storage system was developed for a new balloon-borne gamma-ray telescope. The system incorporates economical consumer products: the portable video cassette recorder (VCR) and a relatively newer item - the digital audio processor. The in-flight recording system employs eight VCRs and will provide a continuous data storage rate of 1.4 megabits/sec throughout a 40 hour balloon flight. Data storage capacity is 25 gigabytes and power consumption is only 10 watts.

  7. Low-cost TDRSS communications for NASA's long duration balloon project

    NASA Technical Reports Server (NTRS)

    Israel, David J.

    1993-01-01

    A new transponder and RF ground support equipment for the NASA Tracking and Data Relay Satellite System (TDRSS) intended to support long duration scientific balloon flights in Antarctica are described. The new balloon class transponder features a highly integrated spread spectrum receiver design based on programmable charge coupled device (CCD) correlators and digital signal processing chips. The correlator chip is a Lincoln Labs 4ABC with four CCD channels. The balloon transponder is capable of reporting an estimate of its input bit error rate using digital signal processing. The TDRSS user RF test set is based on a set of RF ground support equipment capable of providing both the RF communications and direct control and monitoring necessary for transponder testing and a two-way RF link for preflight testing.

  8. Enlargement of basilar artery aneurysms following balloon occlusion--"water-hammer effect". Report of two cases.

    PubMed

    Kwan, E S; Heilman, C B; Shucart, W A; Klucznik, R P

    1991-12-01

    Two patients with distal basilar aneurysms were treated with intra-aneurysmal balloon occlusion. After apparently successful therapy, follow-up angiograms demonstrated aneurysm enlargement with balloon migration distally in the sac. Geometric mismatch between the base of the balloons and the aneurysm neck together with transmitted pulsation through the 2-hydroxyl-ethylmethacrylate (HEMA)-filled balloon directly contributed to aneurysm enlargement. In this report, the authors discuss the problems of progressive aneurysm enlargement due to a "water-hammer effect" and the possibility of hemorrhage following subtotal occlusion.

  9. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration

    PubMed Central

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-01-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment. PMID:27956966

  10. Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.

    PubMed

    Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt

    2012-09-13

    The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.

  11. Non-linear analysis and the design of Pumpkin Balloons: stress, stability and viscoelasticity

    NASA Astrophysics Data System (ADS)

    Rand, J. L.; Wakefield, D. S.

    Tensys have a long-established background in the shape generation and load analysis of architectural stressed membrane structures Founded upon their inTENS finite element analysis suite these activities have broadened to encompass lighter than air structures such as aerostats hybrid air-vehicles and stratospheric balloons Winzen Engineering couple many years of practical balloon design and fabrication experience with both academic and practical knowledge of the characterisation of the non-linear viscoelastic response of the polymeric films typically used for high-altitude scientific balloons Both companies have provided consulting services to the NASA Ultra Long Duration Balloon ULDB Program Early implementations of pumpkin balloons have shown problems of geometric instability characterised by improper deployment and these difficulties have been reproduced numerically using inTENS The solution lies in both the shapes of the membrane lobes and also the need to generate a biaxial stress field in order to mobilise in-plane shear stiffness Balloons undergo significant temperature and pressure variations in flight The different thermal characteristics between tendons and film can lead to significant meridional stress Fabrication tolerances can lead to significant local hoop stress concentrations particularly adjacent to the base and apex end fittings The non-linear viscoelastic response of the envelope film acts positively to help dissipate stress concentrations However creep over time may produce lobe geometry variations that may

  12. [Studies of effects of aluminum oxide nanoparticles after intragastric administration].

    PubMed

    Shumakova, A A; Tananova, O N; Arianova, E A; Mal'tsev, G Iu; Trushina, É N; Mustafina, O K; Guseva, G V; Trusov, N V; Soto, S Kh; Sharanova, N É; Selifanov, A V; Gmoshinskiĭ, I V; Khotimchenko, S A

    2012-01-01

    Growing Wistar rats received intragastrically nanoparticles (NPs) of aluminum oxide (Al2O3) daily during 28 days at doses of 1 or 100 mg per kg body mass. There were studied body mass of animals, relative mass of internals, rate of protein macromolecules absorption in the gut, oxidative damage of DNA, pool of tissue thiols, activity of hepatic enzymes of xenobiotic detoxication system, biochemical and hematological blood indices, stability of lysosome membranes, condition of antioxidant defense system, apoptosis of hepatocytes. Conducted experiments didn't reveal any marked toxic action of Al2O3 NPs on rats after 28 days of administration both in high and low dose. Among effects probably related to NPs influence on animals there were lowering of relative liver and lung masses, decrease of hepatic thiol pool, activity of CYP1A1 isoform in liver and glutathione reductase in erythrocytes, increase of diene conjugates of fatty acids in blood plasma. Said shifts were small in magnitude, didn't come out of margins of physiological norm and didn't show any distinct relation to NPs dose. However considering great importance of this nanomaterial as probable environmental contaminant the studies of it's toxicity must be continued in conditions of low doses (less than 1 mg per kg body mass) for long period of time.

  13. A Review of Balloon Concepts for Titan

    NASA Astrophysics Data System (ADS)

    Lorenz, R. D.

    Concepts for lighter-than-air exploration of Titan are reviewed. Logical vehicle designs with existing power sources (primary batteries, or 100 We-class radioisotope power supplies) are strongly bifurcated into small (few kg) vehicles with lifetimes of only a few hours/days, or larger (100 kg+) vehicles with lifetime of months to years. A wide range of the latter class of vehicle exists, including buoyant-gas and hot-air (Montgolfière) concepts, with and without altitude control or propulsion. An attractive intermediate (10s of kg, but long-lived) class of buoyant gas balloon would be enabled by small (0.5-10 We) radioisotope power supplies, not presently available in the USA. The marginal feasibility of high altitude solar-powered balloons is discussed.

  14. Wind-Based Navigation of a Hot-air Balloon on Titan: A Feasibility Study

    NASA Technical Reports Server (NTRS)

    Furfaro, Roberto; Lunine, Jonathan I.; Elfes, Alberto; Reh, Kim

    2008-01-01

    Current analysis of data streamed back to Earth by the Cassini spacecraft features Titan as one of the most exciting places in the solar system. NASA centers and universities around the US, as well as the European Space Agency, are studying the possibility of sending, as part of the next mission to this giant moon of Saturn, a hot-air balloon (Montgolfier-type) for further and more in-depth exploration. The basic idea would be to design a reliable, semi-autonomous, and yet cheap Montgolfier capable of using continuous flow of waste heat from a power source to lift the balloon and sustain its altitude in the Titan environment. In this paper we study the problem of locally navigating a hot-air balloon in the nitrogen-based Titan atmosphere. The basic idea is to define a strategy (i.e. design of a suitable guidance system) that allows autonomous and semi-autonomous navigation of the balloon using the available (and partial) knowledge of the wind structure blowing on the saturnian satellite surface. Starting from first principles we determined the appropriate thermal and dynamical models describing (a) the vertical dynamics of the balloon and (b) the dynamics of the balloon moving on a vertical plane (2-D motion). Next, various non-linear fuzzy-based control strategies have been evaluated, analyzed and implemented in MATLAB to numerically simulate the capability of the system to simultaneously maintain altitude, as well as a scientifically desirable trajectory. We also looked at the ability of the balloon to perform station keeping. The results of the simulation are encouraging and show the effectiveness of such a system to cheaply and effectively perform semiautonomous exploration of Titan.

  15. Wind-based navigation of a hot-air balloon on Titan: a feasibility study

    NASA Astrophysics Data System (ADS)

    Furfaro, Roberto; Lunine, Jonathan I.; Elfes, Alberto; Reh, Kim

    2008-04-01

    Current analysis of data streamed back to Earth by the Cassini spacecraft features Titan as one of the most exciting places in the solar system. NASA centers and universities around the US, as well as the European Space Agency, are studying the possibility of sending, as part of the next mission to this giant moon of Saturn, a hot-air balloon (Montgolfier-type) for further and more in-depth exploration. The basic idea would be to design a reliable, semi-autonomous, and yet cheap Montgolfier capable of using continuous flow of waste heat from a power source to lift the balloon and sustain its altitude in the Titan environment. In this paper we study the problem of locally navigating a hot-air balloon in the nitrogen-based Titan atmosphere. The basic idea is to define a strategy (i.e. design of a suitable guidance system) that allows autonomous and semi-autonomous navigation of the balloon using the available (and partial) knowledge of the wind structure blowing on the saturnian satellite surface. Starting from first principles we determined the appropriate thermal and dynamical models describing (a) the vertical dynamics of the balloon and (b) the dynamics of the balloon moving on a vertical plane (2-D motion). Next, various non-linear fuzzy-based control strategies have been evaluated, analyzed and implemented in MATLAB to numerically simulate the capability of the system to simultaneously maintain altitude, as well as a scientifically desirable trajectory. We also looked at the ability of the balloon to perform station keeping. The results of the simulation are encouraging and show the effectiveness of such a system to cheaply and effectively perform semi-autonomous exploration of Titan.

  16. Balloon-borne video cassette recorders for digital data storage

    NASA Technical Reports Server (NTRS)

    Althouse, W. E.; Cook, W. R.

    1985-01-01

    A high-speed, high-capacity digital data storage system has been developed for a new balloon-borne gamma-ray telescope. The system incorporates sophisticated, yet easy to use and economical consumer products: the portable video cassette recorder (VCR) and a relatively newer item - the digital audio processor. The in-flight recording system employs eight VCRs and will provide a continuous data storage rate of 1.4 megabits/sec throughout a 40 hour balloon flight. Data storage capacity is 25 gigabytes and power consumption is only 10 watts.

  17. Patient burden and patient preference: comparing magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy.

    PubMed

    Wiarda, Bart M; Stolk, Mark; Heine, Dimitri G N; Mensink, Peter; Thieme, Mai E; Kuipers, Ernst J; Stoker, Jaap

    2013-03-01

    We aimed to prospectively determine patient burden and patient preference for magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy in patients with suspected or known Crohn's disease (CD) or occult gastrointestinal bleeding (OGIB).  Consecutive consenting patients with CD or OGIB underwent magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy. Capsule endoscopy was only performed if magnetic resonance enteroclysis showed no high-grade small bowel stenosis. Patient preference and burden was evaluated by means of standardized questionnaires at five moments in time. From January 2007 until March 2009, 76 patients were included (M/F 31/45; mean age 46.9 years; range 20.0-78.4 years): 38 patients with OGIB and 38 with suspected or known CD. Seventeen patients did not undergo capsule endoscopy because of high-grade stenosis. Ninety-five percent (344/363) of the questionnaires were suitable for evaluation. Capsule endoscopy was significantly favored over magnetic resonance enteroclysis and balloon-assisted enteroscopy with respect to bowel preparation, swallowing of the capsule (compared to insertion of the tube/scope), burden of the entire examination, duration and accordance with the pre-study information. Capsule endoscopy and magnetic resonance enteroclysis were significantly preferred over balloon-assisted enteroscopy for clarity of explanation of the examination, and magnetic resonance enteroclysis was significantly preferred over balloon-assisted enteroscopy for bowel preparation, painfulness and burden of the entire examination. Balloon-assisted enteroscopy was significantly favored over magnetic resonance enteroclysis for insertion of the scope and procedure duration. Pre- and post-study the order of preference was capsule endoscopy, magnetic resonance enteroclysis and balloon-assisted enteroscopy. Capsule endoscopy was preferred to magnetic resonance enteroclysis and balloon-assisted enteroscopy

  18. Overview of and first observations from the TILDAE High-Altitude Balloon Mission

    NASA Astrophysics Data System (ADS)

    Maruca, Bennett A.; Marino, Raffaele; Sundkvist, David; Godbole, Niharika H.; Constantin, Stephane; Carbone, Vincenzo; Zimmerman, Herb

    2017-04-01

    Though the presence of intermittent turbulence in the stratosphere has been well established, much remains unknown about it. In situ observations of this phenomenon, which have provided the greatest details of it, have mostly been achieved via sounding balloons (i.e., small balloons which burst at peak altitude) carrying constant-temperature hot-wire anemometers (CTAs). The Turbulence and Intermittency Long-Duration Atmospheric Experiment (TILDAE) was developed to test a new paradigm for stratospheric observations. Rather than flying on a sounding balloon, TILDAE was incorporated as an add-on experiment to the payload of a NASA long-duration balloon mission that launched in January 2016 from McMurdo Station, Antarctica. Furthermore, TILDAE's key instrument was a sonic anemometer, which (relative to a CTA) provides better-calibrated measurements of wind velocity and a more robust separation of velocity components. During the balloon's ascent, TILDAE's sonic anemometer provided atmospheric measurements up to an altitude of about 18 km, beyond which the ambient air pressure was too low for the instrument to function properly. Efforts are currently underway to scientifically analyze these observations of small-scale fluctuations in the troposphere, tropopause, and stratosphere and to develop strategies for increasing the maximum operating altitude of the sonic anemometer.

  19. Daytime Aspect Camera for Balloon Altitudes

    NASA Technical Reports Server (NTRS)

    Dietz, Kurt L.; Ramsey, Brian D.; Alexander, Cheryl D.; Apple, Jeff A.; Ghosh, Kajal K.; Swift, Wesley R.

    2002-01-01

    We have designed, built, and flight-tested a new star camera for daytime guiding of pointed balloon-borne experiments at altitudes around 40 km. The camera and lens are commercially available, off-the-shelf components, but require a custom-built baffle to reduce stray light, especially near the sunlit limb of the balloon. This new camera, which operates in the 600- to 1000-nm region of the spectrum, successfully provides daytime aspect information of approx. 10 arcsec resolution for two distinct star fields near the galactic plane. The detected scattered-light backgrounds show good agreement with the Air Force MODTRAN models used to design the camera, but the daytime stellar magnitude limit was lower than expected due to longitudinal chromatic aberration in the lens. Replacing the commercial lens with a custom-built lens should allow the system to track stars in any arbitrary area of the sky during the daytime.

  20. Catchment-scale snow depth monitoring with balloon photogrammetry

    NASA Astrophysics Data System (ADS)

    Durand, M. T.; Li, D.; Wigmore, O.; Vanderjagt, B. J.; Molotch, N. P.; Bales, R. C.

    2016-12-01

    Field campaigns and permanent in-situ facilities provide extensive measurements of snowpack properties at catchment (or smaller) scales, and have consistently improved our understanding of snow processes and the estimation of snow water resources. However, snow depth, one of the most important snow states, has been measured almost entirely with discrete point-scale samplings in field measurements; spatiotemporally continuous snow depth measurements are nearly nonexistent, mainly due to the high cost of airborne flights and the ban of Unmanned Aerial Systems in many areas (e.g. in all the national parks). In this study, we estimate spatially continuous snow depth from photogrammetric reconstruction of aerial photos taken from a weather balloon. The study was conducted in a 0.2 km2 watershed in Wolverton, Sequoia National Park, California. We tied a point-and-shoot camera on a helium-inflated weather balloon to take aerial images; the camera was scripted to automatically capture images every 3 seconds and to record the camera position and orientation at the imaging times using a built-in GPS. With the 2D images of the snow-covered ground and the camera position and orientation data, the 3D coordinates of the snow surface were reconstructed at 10 cm resolution using photogrammetry software PhotoScan. Similar measurements were taken for the snow-free ground after snowmelt, and the snow depth was estimated from the difference between the snow-on and snow-off measurements. Comparing the photogrammetric-estimated snow depths with the 32 manually measured depths, taken at the same time as the snow-on balloon flight, we find the RMSE of the photogrammetric snow depth is 7 cm, which is 2% of the long-term peak snow depth in the study area. This study suggests that the balloon photogrammetry is a repeatable, economical, simple, and environmental-friendly method to continuously monitor snow at small-scales. Spatiotemporally continuous snow depth could be regularly measured in

  1. Electrodynamics of the stratosphere using 5000 m3 superpressure balloons

    NASA Astrophysics Data System (ADS)

    Holzworth, R. H.

    Recently the U. S. National Science Foundation and NASA have begun support of a long duration balloon-borne experiment to study electrical properties of the upper atmosphere. This research project titled EMA (Electrodynamics of the Middle Atmopshere) involves the design of a microprocessor controlled payload and the launch of up to eight small superpressure balloons during 1982 through early 1984. The primary payload instrument will measure the vector electric field from DC to 10 kHz and the payloads will include instruments to measure local ionization, electrical conductivity, magnetic field, pressure and temperature fluctuations and to record optical lightning. Measurement of these parameters in the stratosphere from a few balloons simultaneously for periods extending over a few solar rotations will enable us to study (1) electrical coupling between the atmosphere and magnetosphere, (2) global current systems, (3) global response to solar flares and magnetospheric storms and many other outstanding problems. In order to obtain long duration flights, it is necessary to fly in the southern hemisphere where the balloons are expected to circle the globe dozens of times in their lifetimes. Thus the balloons will be out of direct communication with any one ground station most of the time so the telemetry will be relayed via satellite. This severely limits the data rates resulting in the need for on-board data processing. This is accomplished through the use of dual microcomputers for data analysis and for telemetry formatting. This talk will concentrate on a description of our payload design as driven by the scientific requirements. Examples of the types of electric field signatures we expect to be able to distinguish will also be presented.

  2. A comparison of Loon balloon observations and stratospheric reanalysis products

    NASA Astrophysics Data System (ADS)

    Friedrich, Leon S.; McDonald, Adrian J.; Bodeker, Gregory E.; Cooper, Kathy E.; Lewis, Jared; Paterson, Alexander J.

    2017-01-01

    Location information from long-duration super-pressure balloons flying in the Southern Hemisphere lower stratosphere during 2014 as part of X Project Loon are used to assess the quality of a number of different reanalyses including National Centers for Environmental Prediction Climate Forecast System version 2 (NCEP-CFSv2), European Centre for Medium-Range Weather Forecasts (ERA-Interim), NASA Modern Era Retrospective-Analysis for Research and Applications (MERRA), and the recently released MERRA version 2. Balloon GPS location information is used to derive wind speeds which are then compared with values from the reanalyses interpolated to the balloon times and locations. All reanalysis data sets accurately describe the winds, with biases in zonal winds of less than 0.37 m s-1 and meridional biases of less than 0.08 m s-1. The standard deviation on the differences between Loon and reanalyses zonal winds is latitude-dependent, ranging between 2.5 and 3.5 m s-1, increasing equatorward. Comparisons between Loon trajectories and those calculated by applying a trajectory model to reanalysis wind fields show that MERRA-2 wind fields result in the most accurate simulated trajectories with a mean 5-day balloon-reanalysis trajectory separation of 621 km and median separation of 324 km showing significant improvements over MERRA version 1 and slightly outperforming ERA-Interim. The latitudinal structure of the trajectory statistics for all reanalyses displays marginally lower mean separations between 15 and 35° S than between 35 and 55° S, despite standard deviations in the wind differences increasing toward the equator. This is shown to be related to the distance travelled by the balloon playing a role in the separation statistics.

  3. Effect of routine rapid insertion of Bakri balloon tamponade on reducing hemorrhage from placenta previa during and after cesarean section.

    PubMed

    Soyama, Hiroaki; Miyamoto, Morikazu; Sasa, Hidenori; Ishibashi, Hiroki; Yoshida, Masashi; Nakatsuka, Masaya; Takano, Masashi; Furuya, Kenichi

    2017-09-01

    To evaluate the effectiveness of routine rapid insertion of a Bakri balloon during cesarean section for placenta previa based on a retrospective control study. Women with singleton pregnancies who underwent cesarean section for placenta previa at our institution between 2003 and 2016 were enrolled. Between 2015 and 2016, women who routinely underwent balloon tamponade during cesarean section were defined as the balloon group. Between 2003 and 2014, women who underwent no hemostatic procedures except balloon tamponade were defined as the non-balloon group. The clinical outcomes of the two groups were retrospectively analyzed. Of the 266 women with placenta previa, 50 were in the balloon group and 216 were in the non-balloon group. The bleeding amounts were significantly smaller in the balloon group than in the non-balloon group: intraoperative bleeding (991 vs. 1250 g, p < 0.01), postoperative bleeding (62 vs. 150 g, p < 0.01), and total bleeding (1066 vs. 1451 g, p < 0.01). Furthermore, the mean surgical duration was shorter in the balloon group than the non-balloon group (30 vs. 50 min, p < 0.01). In the balloon group, five patients suffered from increasing hemorrhage due to prolapse of the balloon from the uterus after the operation, but the hemorrhage was controlled by balloon re-insertion without additional hemostatic procedures. This study demonstrated that the routine rapid insertion of Bakri balloon tamponade during cesarean section significantly decreased intra- and postoperative hemorrhage and shortened the surgical duration in women with placenta previa.

  4. NASA Super Pressure Balloon

    NASA Technical Reports Server (NTRS)

    Fairbrother, Debbie

    2017-01-01

    NASA is in the process of qualifying the mid-size Super Pressure Balloon (SPB) to provide constant density altitude flight for science investigations at polar and mid-latitudes. The status of the development of the 18.8 million cubic foot SPB capable of carrying one-tone of science to 110,000 feet, will be given. In addition, the operating considerations such as launch sites, flight safety considerations, and recovery will be discussed.

  5. NASA Super Pressure Balloon

    NASA Technical Reports Server (NTRS)

    Fairbrother, Debbie

    2016-01-01

    NASA is in the process of qualifying the mid-size Super Pressure Balloon (SPB) to provide constant density altitude flight for science investigations at polar and mid-latitudes. The status of the development of the 18.8 million cubic foot SPB capable of carrying one-tonne of science to 110,000 feet, will be given. In addition, the operating considerations such as launch sites, flight safety considerations, and recovery will be discussed.

  6. Analysis of intra-aortic balloon pump model with ovine myocardial infarction.

    PubMed

    Abdolrazaghi, Mona; Navidbakhsh, Mahdi; Hassani, Kamran; Rabbani, Shahram; Ahmadi, Hossein

    2009-12-01

    In this study, we have tried to model the effects of intra-aortic balloon pump (IABP) on myocardial infarction (MI) using the standardized data of MI in sheep which was obtained by ligation of the left anterior descending coronary artery. Mathematical model of whole cardiovascular system was presented in accordance to the arterial tree. The lumped parameter model was primarily obtained for a rigid vessel regarding the vessel diameter. In this study, the proper lumped model of every vessel was obtained by incorporating the rigid vessel lumped model into the capacitance as a compliance of the vessel. Intra-aortic balloon pump was modeled with the hemodynamic parameters of the aorta. It was assumed that balloon pump inflates at the beginning of the diastole and deflates near the beginning of the next systole. During balloon pumping, the vessel diameter variation function counter pulsates sinusoidally with the same period of the cardiac cycle. End systolic pressure and end diastolic pressure decreases along with hemodynamic flow optimized through systemic arteries due to balloon pumping in diastole. It has been shown that the blood flow in subclavian artery increases as well. Moreover, the cardiac work keeps low, which prone to lower oxygen consumption. The results of modeling are in good agreement with IABP documentation. The presented model is a useful tool for studying of the cardiovascular system pathology and the presented modeling data are in good agreement with the experimental ones.

  7. Comparison of double-balloon and single-balloon enteroscope for therapeutic endoscopic retrograde cholangiography after Roux-en-Y small bowel surgery.

    PubMed

    De Koning, Michael; Moreels, Tom G

    2016-08-22

    Roux-en-Y reconstructive surgery excludes the biliopancreatic system from conventional endoscopic access. Balloon-assisted enteroscopy allows therapeutic endoscopic retrograde cholangiopancreatography (ERCP) in these patients, avoiding rescue surgery. The objective of the current study is to compare success and complication rate of double-balloon (DBE) and single-balloon enteroscope (SBE) to perform ERCP in Roux-en-Y patients. Seventy three Roux-en-Y patients with suspected biliary tract pathology underwent balloon-assisted enteroscopy in a tertiary-care center. Retrospective analysis of 95 consecutive therapeutic ERCP procedures was performed to define and compare success and complication rate of DBE and SBE. Male-female ratio was 28/45 with a mean age of 58 ± 2 years. 30 (32 %) procedures were performed with DBE and 65 (68 %) with SBE. Overall ERCP success rate was 73 % for DBE and 75 % for SBE (P = 0.831). Failure was due to inability to reach or cannulate the intact papilla or bilioenteric anastomosis. Success rate was significantly higher when performed at the bilioenteric anastomosis (80 % success in 56 procedures) or at the intact papilla in short-limb Roux-en-Y (80 % in 15 procedures) as compared to the intact papilla in long-limb (58 % in 24 procedures; P = 0.040). Adverse event rates were 10 % (DBE) and 8 % (SBE) (P = 0.707) and mostly dealt with conservatively. ERCP after Roux-en-Y altered small bowel anatomy is feasible and safe using both DBE and SBE. Both techniques are equally competent with high success rates and acceptable adverse events rates. ERCP at the level of the intact papilla in long limb Roux-en-Y is less successful as compared to short-limb or bilioenteric anastomosis.

  8. [Interventional catheter treatment of bypass graft stenosis: comparison of intracoronary stent implantation and balloon angioplasty].

    PubMed

    Heidland, U E; Heintzen, M P; Schoppmann, D; Michel, C J; Strauer, B E

    2000-02-25

    Balloon angioplasty of a stenosed bypass graft has a much higher risk of recurrent stenosis than dilatation of a stenosed native coronary artery. Intracoronary stent implantation has established itself as the better treatment of native coronary artery stenosis than conventional balloon angioplasty. However, there is still uncertainty whether intracoronary stent implantation in stenosed bypass vessels gives better long-term results than conventional balloon angioplasty. Results were retrospectively analyzed of unrandomized 224 primarily successful interventions--122 balloon dilatations and 102 stent implantations--performed between January 1996 and June 1998 on stenosed coronary bypass grafts, re-examined by coronary angiography an average of 6 months later. All but 11 patients were on combined aspirin and ticlopidine antiplatelet aggregation treatment. There was a significantly lower 6-month restenosis rate (30.4%) after stent implantation than after balloon dilatation (51.6%). The re-intervention rate was also significantly lower after stent implantation. These data suggest that stent implantation of stenosed coronary bypass grafts under cover of platelet-aggregation inhibition with aspirin and ticlopidine provides a lower restenosis and thus higher revascularization rate than conventional balloon dilatation.

  9. An automatic parachute release for high altitude scientific balloons

    NASA Astrophysics Data System (ADS)

    Field, Chris

    NASA's Columbia Scientific Balloon Facility launches high altitude scientific research balloons at many locations around the world. Locations like Antarctica are flat for hundreds of miles and have nothing to snag a parachute consequently causing it to be more important to separate the parachute from the payload than in an area with vegetation and fences. Scientists are now building one of a kind payloads costing millions of dollars, taking five years or more to build, and are requesting multiple flights. In addition to that, the data gathering rate of many science payloads far exceeds the data downlink rate on over-the-horizon flights therefore making a recovery of at least the data hard drives a "minimum success requirement". The older mentality in ballooning; separating the parachute and payload from the balloon and getting it on the ground is more important than separating the parachute after the payload is on the ground has changed. It is now equally as important to separate the parachute from the gondola to prevent damage from dragging. Until now, commands had to be sent to separate the parachute from the gondola at approximately 60K ft, 30K ft, and 10K ft to use the Semi Automatic Parachute Release (SAPR), which is after the sometimes violent parachute opening shock. By using the Gondola controlled Automatic Parachute Release (GAPR) all commanding is done prior to termination, making the parachute release fully autonomous.

  10. Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation

    PubMed Central

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R.

    2015-01-01

    Abstract The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. PMID:25959284

  11. Results from the Balloon Ozone Intercomparison Campaign (BOIC)

    NASA Technical Reports Server (NTRS)

    Hilsenrath, E.; Hagemeyer, R.; Mentall, J.; Torres, A.; Attmannspacher, W.; Bass, A.; Evans, W.; Barnes, R. A.; Komhyr, W.; Robbins, D.

    1986-01-01

    Data from the BOIC which consisted of three balloon missions conducted in Palestine, Texas from June 1983 to March 1984 are presented. The BOIC was to assess the ability to perform ozone measurements from balloon platforms. The accuracy and precision of the various ozone measurement systems, which were composed of a photometer, a mass spectrometer, and solar UV absorption sensors, are evaluated. The ozone observations obtained with the instruments on the three flight missions are analyzed and intercompared. The flight in situ data are also compared to the National Bureau of Standards reference photometer, satellite measurements, and under simulated stratospheric pressure and ozone concentrations.

  12. Balloon fabrics made of Goldbeater's skins

    NASA Technical Reports Server (NTRS)

    Chollet, L

    1922-01-01

    Goldbeater's skin, which is the prepared outside membrane of the large intestine of an ox, is examined as a balloon fabric and details of how goldbeater's skin is prepared for use are provided. The construction techniques employed by Germany, France, and England are all discussed.

  13. Controlled meteorological (CMET) balloon profiling of the Arctic atmospheric boundary layer

    NASA Astrophysics Data System (ADS)

    Roberts, Tjarda; Hole, Lars; Voss, Paul

    2017-04-01

    We demonstrate profiling of the atmospheric boundary layer over Arctic ice-free and sea-ice covered regions by free-floating controllable CMET balloons. The CMET observations (temperature, humidity, wind-speed, pressure) provide in-situ meteorological datasets in very remote regions for comparison to atmospheric models. Controlled Meteorological (CMET) balloons are small airborne platforms that use reversible lift-gas compression to regulate altitude. These balloons have approximately the same payload mass as standard weather balloons but can float for many days, change altitude on command, and transmit meteorological and system data in near-real time via satellite. Five Controlled Meteorological (CMET) balloons were launched from Ny-Ålesund in Svalbard (Spitsbergen) over 5-12 May 2011 and measured vertical atmospheric profiles (temperature, humidity, wind) over coastal and remote areas to both the east and west. One notable CMET flight achieved a suite of 18 continuous soundings that probed the Arctic atmospheric boundary layer (ABL) over a period of more than 10 h. Profiles from two CMET flights are compared to model output from ECMWF Era-Interim reanalysis (ERA-I) and to a high-resolution (15 km) Arctic System Reanalysis (ASR) product. To the east of Svalbard over sea-ice, the CMET observed a stable ABL profile with a temperature inversion that was reproduced by ASR but not captured by ERA-I. In a coastal ice-free region to the west of Svalbard, the CMET observed a stable ABL with strong wind-shear. The CMET profiles document increases in ABL temperature and humidity that are broadly reproduced by both ASR and ERA-I. The ASR finds a more stably stratified ABL than observed but captured the wind shear in contrast to ERA-I. Detailed analysis of the coastal CMET-automated soundings identifies small-scale temperature and humidity variations with a low-level flow and provides an estimate of local wind fields. We show that CMET balloons are a valuable approach for

  14. TLE Balloon experiment campaign carried out on 25 August 2006 in Japan

    NASA Astrophysics Data System (ADS)

    Takahashi, Y.; Chikada, S.; Yoshida, A.; Adachi, T.; Sakanoi, T.

    2006-12-01

    The balloon observation campaign for TLE and lightning study was carried out 25 August 2006 in Japan by Tohoku University, supported by JAXA. The balloon was successfully launched at 18:33 LT at Sanriku Balloon Center of JAXA located in the east coast of northern part of Japan (Iwate prefecture). Three types of scientific payloads were installed at the 1 m-cubic gondola, that is, 3-axis VLF electric filed antenna and receiver (VLFR), 4 video frame CCD cameras (CCDI) and 2-color photometer (PM). The video images were stored in 4 HD video recorders, which have 20GB memories respectively, at 30 frames/sec and VLFR and PM data were put into digital data recorder with 30 GB memory at sampling rate of 100 kHz. The balloon floated at the altitude of 13 km until about 20:30 LT, going eastward and went up to 26 km at a distance of 130 km from the coast. And it went back westward at the altitude of 26 km until midnight. The total observation period is about 5 hours. Most of the equipments worked properly except for one video recorder. Some thunderstorms existed within the direct FOV from the balloon in the range of 400-600 km and more than about 400 lightning flashes were recorded as video images. We confirmed that, at least, one sprite halo was captured by CCDI which occurred in the oceanic thunderstorm at a distance of about 500 km from balloon. This is the first TLE image obtained by a balloon-borne camera. Simultaneous measurements of VLF sferics and lightning/TLE images will clarify the role of intracloud (IC) currents in producing and/or modulating TLEs as well as cloud-to-ground discharges (CG). Especially the effect of horizontal components will be investigated in detail, which cannot be detected on the ground, to explain the unsolved properties of TLEs, such as long time delay of TLE from the timing of stroke and large horizontal displacement between CG and TLEs.

  15. Balloon-Borne, High-Energy Astrophysics: Experiences from the 1960s to the 1980s

    NASA Technical Reports Server (NTRS)

    Fishman, Gerald J.

    2008-01-01

    Observational high-energy astrophysics in the hard-x-ray and gamma-ray regions owes its development and initial successes to the balloon-borne development of detector systems, as well as pioneering observations, primarily in the timeframe from the 1960s to the 1990s. I will describe some of the first observations made by the Rice University balloon group in the 1960s, including the impetus for these observations. The appearance of SN 1987a led to several balloon-flight campaigns, sponsored by NASA, from Alice Springs, Australia in 1987 and 1988. During the 1980s, prototypes of instruments for the Compton Gamma Ray Observatory were flown on many balloon flights, which greatly enhanced the success of that mission.

  16. Determination of constant-volume balloon capabilities for aeronautical research. [specifically measurement of atmospheric phenomena

    NASA Technical Reports Server (NTRS)

    Tatom, F. B.; King, R. L.

    1977-01-01

    The proper application of constant-volume balloons (CVB) for measurement of atmospheric phenomena was determined. And with the proper interpretation of the resulting data. A literature survey covering 176 references is included. the governing equations describing the three-dimensional motion of a CVB immersed in a flow field are developed. The flowfield model is periodic, three-dimensional, and nonhomogeneous, with mean translational motion. The balloon motion and flow field equations are cast into dimensionless form for greater generality, and certain significant dimensionless groups are identified. An alternate treatment of the balloon motion, based on first-order perturbation analysis, is also presented. A description of the digital computer program, BALLOON, used for numerically integrating the governing equations is provided.

  17. An observational study of ballooning in large spiders: Nanoscale multifibers enable large spiders' soaring flight.

    PubMed

    Cho, Moonsung; Neubauer, Peter; Fahrenson, Christoph; Rechenberg, Ingo

    2018-06-01

    The physical mechanism of aerial dispersal of spiders, "ballooning behavior," is still unclear because of the lack of serious scientific observations and experiments. Therefore, as a first step in clarifying the phenomenon, we studied the ballooning behavior of relatively large spiders (heavier than 5 mg) in nature. Additional wind tunnel tests to identify ballooning silks were implemented in the laboratory. From our observation, it seems obvious that spiders actively evaluate the condition of the wind with their front leg (leg I) and wait for the preferable wind condition for their ballooning takeoff. In the wind tunnel tests, as-yet-unknown physical properties of ballooning fibers (length, thickness, and number of fibers) were identified. Large spiders, 16-20 mg Xysticus spp., spun 50-60 nanoscale fibers, with a diameter of 121-323 nm. The length of these threads was 3.22 ± 1.31 m (N = 22). These physical properties of ballooning fibers can explain the ballooning of large spiders with relatively light updrafts, 0.1-0.5 m s-1, which exist in a light breeze of 1.5-3.3 m s-1. Additionally, in line with previous research on turbulence in atmospheric boundary layers and from our wind measurements, it is hypothesized that spiders use the ascending air current for their aerial dispersal, the "ejection" regime, which is induced by hairpin vortices in the atmospheric boundary layer turbulence. This regime is highly correlated with lower wind speeds. This coincides well with the fact that spiders usually balloon when the wind speed is lower than 3 m s-1.

  18. Successful Kissing Balloon Expandable Stent Graft Treatment for a Right Common Carotid Pseudoaneurysm Caused by Tracheotomy.

    PubMed

    Agyei, Justice O; Alvarez, Cynthia; Iqbal, Azher; Fanous, Andrew A; Siddiqui, Adnan H

    2018-06-01

    A rare complication following tracheotomy is common carotid artery (CCA) pseudoaneurysm. Treatment modalities for CCA pseudoaneurysm include surgical repair and single-artery balloon-covered stent graft technique. We describe successful treatment of tracheotomy-related CCA pseudoaneurysm with the "kissing balloon" expandable stent graft technique. We successfully implemented the kissing balloon expandable stent graft technique for treatment of a large, narrow-necked, bilobed CCA pseudoaneurysm that arose owing to a tracheotomy complication. The pseudoaneurysm was detected while performing a diagnostic angiogram of the aortic arch and surrounding vessels. The stent was deployed while the 2 balloons were introduced in a kissing manner such that they faced one another to avoid occlusion of either branch of the innominate artery coming into contact; 1 balloon was inflated at the origin of the right subclavian artery, and the other was inflated at the right innominate artery simultaneously. The pseudoaneurysm was successfully contained; normal blood flow was restored in the CCA. The balloons were deflated and withdrawn. The patient remained neurologically intact after the procedure. The kissing balloon technique is a safe and effective alternative to surgical repair, as it prevents morbidities associated with the surgical procedure. Also, this technique decreases the risk of major side-branch occlusion associated with the single-artery balloon-covered stent graft technique. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer to simultaneously obtain spatial and spectral information on science targets; the long baseline provides subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

  20. Tethered balloon-based measurements of meteorological variables and aerosols

    NASA Technical Reports Server (NTRS)

    Sentell, R. J.; Storey, R. W.; Chang, J. J. C.; Jacobsen, S. J.

    1976-01-01

    Tethered balloon based measurements of the vertical distributions of temperature, humidity, wind speed, and aerosol concentrations were taken over a 4-hour period beginning at sunrise on June 29, 1976, at Wallops Island, Virginia. Twelve consecutive profiles of each variable were obtained from ground to about 500 meters. These measurements were in conjuction with a noise propagation study on remotely arrayed acoustic range (ROMAAR) at Wallops Flight Center. An organized listing of these vertical soundings is presented. The tethered balloon system configuration utilized for these measurements is described.