Sample records for biometry

  1. Biometry | Division of Cancer Prevention

    Cancer.gov

    [[{"fid":"66","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Biometry Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Biometry Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Biometry Research Group Homepage Logo","title":"Biometry Research Group Homepage

  2. Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

    PubMed

    Kolega, Marija Škara; Kovačević, Suzana; Čanović, Samir; Pavičić, Ana Didović; Bašić, Jadranka Katušić

    2015-03-01

    Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included in this prospective randomized trial. Twenty eyes underwent IOL master and 20 eyes had aplanation ultrasound biometry. There were included only eyes with age-related cataract and postoperative natural visual acuity (VA) 0.7. Visual acuity was performed 6 weeks after cataract surgery. After 6 weeks best natural visual acuity were 0.9 (± 0.1) in IOL-Master group and 0.85 (± 0.15) in ultrasound biometry. The postoperative mean absolute refractive error was 0.75 (± 0.5) D for ultrasound biometry and 0.50 (± 0.50) D for IOL-Master. Optical biometry with the IOL-Master proved to be slightly more accurate than ultrasound biometry for IOL power calculation.

  3. Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry.

    PubMed

    Kunert, Kathleen S; Peter, Monika; Blum, Marcus; Haigis, Wolfgang; Sekundo, Walter; Schütze, Juliane; Büehren, Tobias

    2016-01-01

    To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Würzburg, and Philipps University, Marburg, Germany. Prospective comparative multicenter clinical study. Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept-source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept-source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 μm ± 25 (SD), 17 ± 122 μm, and -0.001 ± 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 ± 122 μm and 0.15 ± 4.51 μm, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 μm, 9.8 μm, 2.3 μm, 19.5 μm, and 0.1 D, respectively. Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes. Drs. Blum and Sekundo are members of the Scientific Advisory Board of Carl Zeiss Meditec AG. Drs. Peter and Bühren are employees of Carl Zeiss Meditec AG. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Fetal Biometry Studies of Malaysian Pregnant Women and Comparison with International Charts

    NASA Astrophysics Data System (ADS)

    Adam, N.; Ramli, R. M.; Jaafar, M. S.

    2010-07-01

    Fetal biometry is a measurement done on fetus anatomy to relate the fetus growth with gestational age (GA). In this study [1], fetal biometry that was studied consists of biparietal diameter (BPD), abdominal circumference (AC) and femur length (FL). Studies were carried out at Maternity Unit, Hospital Pulau Penang. From the finding, it is understood that fetal biometry distinguish the normal from abnormal fetal structures and it vary among different populations, depending upon their racial [2,3] and nutrition [4,5,6]. True findings are valuable in estimating the gestational age of the fetus, abnormalities in fetus and the consideration of maternal health specific to the Malaysian population.

  5. Comparison of postoperative refractive outcomes: IOLMaster® versus immersion ultrasound.

    PubMed

    Whang, Woong-Joo; Jung, Byung-Ju; Oh, Tae-Hoon; Byun, Yong-Soo; Joo, Choun-Ki

    2012-01-01

    To compare the postoperative refractive outcomes between IOLMaster biometry (Carl Zeiss Meditec, Inc., Dublin, CA) and immersion ultrasound biometry for axial length measurements. Refractive outcomes in 354 eyes were compared using the IOLMaster and the immersion ultrasound biometry. Predicted refraction was determined using manual keratometry and the SRK-T formula with personalized A-constant. The axial lengths measured using the IOLMaster and immersion ultrasound were 24.49 ± 2.11 and 24.46 ± 2.11 mm, respectively, and the difference was significant (P < .05). The mean errors were 0.000 ± 0.578 D with the IOLMaster, and 0.000 ± 0.599 D with the immersion ultrasound, but the difference was not significant. The mean absolute error was smaller with the IOLMaster than with immersion ultrasound (0.463 ± 0.341 vs 0.479 ± 0.359 D), but the difference was not significant. IOLMaster biometry yields highly accurate results in cataract surgery. However, if the IOLMaster is unavailable, immersion ultrasound biometry with personalized intraocular lens constants is an acceptable alternative. Copyright 2012, SLACK Incorporated.

  6. Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study.

    PubMed

    Pongsachareonnont, Pear; Tangjanyatam, Sagol

    2018-01-01

    We compared the accuracy of axial length (AL) measurement obtained by optical biometry with that obtained by acoustic biometry in eyes with rhegmatogenous retinal detachment (RRD). This prospective descriptive analytic study measured the AL of eyes with RRD preoperatively and 3 months postoperatively using optical biometry (intraocular lens [IOL] master group) and acoustic biometry (immersion A-scan group). Preoperative and postoperative measurements were compared by paired t -test. The agreement between preoperative and postoperative measurements was analyzed using a Bland-Altman plot. Subgroup analysis of macular involvement status was performed. Twenty-seven eyes were analyzed in this study. The mean AL in the IOL master group was 23.58±0.97 mm preoperatively and 24.17±1.16 mm postoperatively; the mean difference was -0.59±0.90 mm ( P = 0.007). The mean AL in the immersion A-scan group was 24.29±1.59 mm preoperatively and 24.27±1.69 mm postoperatively; the mean difference was 0.02±0.48 mm ( P = 0.827). Bland-Altman analysis revealed disagreement between preoperative and postoperative AL measurements in both techniques. In subgroup analysis of macula with RRD, there were significant differences between preoperative and postoperative AL measurements in the IOL master group ( P = 0.014). Significant underestimation of AL measurement was observed when using the IOL master in eyes with RRD with macular involvement, which could affect IOL power selection.

  7. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes

    PubMed Central

    Mao, Xinjie; Banta, James T.; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    Purpose To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Methods Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Results Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. Conclusions The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye. PMID:27010674

  8. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    PubMed

    Mao, Xinjie; Banta, James T; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  9. Whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography

    PubMed Central

    Zhong, Jianguang; Tao, Aizhu; Xu, Zhe; Jiang, Hong; Shao, Yilei; Zhang, Huicheng; Liu, Che; Wang, Jianhua

    2014-01-01

    PURPOSE To investigate changes of whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography (UL-OCT). DESIGN Prospective, observational case series. METHODS Twenty-one adult subjects were enrolled. Using UL-OCT, the left eye of each subject was imaged with relaxed (0 D) and accommodative stimuli (+6 D). Full eye biometry included central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness, vitreous length and axial length (AL). RESULTS During accommodation (+6 D), the axial biometry of the whole eye changed significantly. Compared to the rest state, ACD at the accommodative state decreased significantly from 3.128 ± 0.305 mm to 2.961 ± 0.298 mm (paired t-test, P < 0.001). The lens thickness increased significantly from 3.723 ± 0.237 mm to 3.963 ± 0.234 mm (P < 0.001). The vitreous length decreased significantly from 17.129 ± 0.864 mm to 17.057± 0.848 mm (P < 0.001). AL was 24.519 ± 0.917 mm at the rest state and increased to 24.545±0.915 mm with +6 D accommodation stimulus. The elongated AL of 26.1 ± 13.4 μm between the rest and accommodative states was significant (P < 0.001). CONCLUSIONS During accommodation, whole eye axial biometry changed, including a decrease in ACD and vitreous length, and an increase in lens thickness and AL. UL-OCT provides an alternative method that is suitable for full eye biometry during accommodation. PMID:24487051

  10. Comparison of intraocular lens power prediction using immersion ultrasound and optical biometry with and without formula optimization.

    PubMed

    Nemeth, Gabor; Nagy, Attila; Berta, Andras; Modis, Laszlo

    2012-09-01

    Comparison of postoperative refraction results using ultrasound biometry with closed immersion shell and optical biometry. Three hundred and sixty-four eyes of 306 patients (age: 70.6 ± 12.8 years) underwent cataract surgery where intraocular lenses calculated by SRK/T formula were implanted. In 159 cases immersion ultrasonic biometry, in 205 eyes optical biometry was used. Differences between predicted and actual postoperative refractions were calculated both prior to and after optimization with the SRK/T formula, after which we analysed the similar data in the case of Holladay, Haigis, and Hoffer-Q formulas. Mean absolute error (MAE) and the percentage rate of patients within ±0.5 and ±1.0 D difference in the predicted error were calculated with these four formulas. MAE was 0.5-0.7 D in cases of both methods with SRK/T, Holladay, and Hoffer-Q formula, but higher with Haigis formula. With no optimization, 60-65 % of the patients were under 0.5 D error in the immersion group (except for Haigis formula). Using the optical method, this value was slightly higher (62-67 %), however, in this case, Haigis formula also did not perform so well (45 %). Refraction results significantly improved with Holladay, Hoffer-Q, and Haigis formulas in both groups. The rate of patients under 0.5 D error increased to 65 % by the immersion technique, and up to 80 % by the optical one. According to our results, optical biometry offers only slightly better outcomes compared to those of immersion shell with no optimized formulas. However, in case of new generation formulas with both methods, the optimization of IOL-constants give significantly better results.

  11. The effect of the timing of the cessation of contact lens use on the results of biometry.

    PubMed

    Goudie, Colin; Tatham, Andrew; Davies, Rhys; Sifton, Alison; Wright, Mark

    2018-06-01

    Current guidelines vary regarding when to remove contact lenses prior to performing biometry, and there is no clear evidence behind these guidelines. This study aimed to determine the effect of soft contact lens wear on biometric measurements by examining the change in predicted lens power for emmetropia at several time points following removal of soft contact lenses. A prospective, controlled study of healthy soft contact lens wearers. Biometry was performed immediately after removing contact lenses and then after 2, 4 and 7 days of no contact lens use. Healthy non-contact lens wearers were used as controls. All measurements were taken with the Zeiss IOLMaster. In all, 14 subjects and 13 controls were recruited. There was no significant difference in age or gender between groups. Eight of the fourteen subjects wore daily disposable CLs, two wore 2-weekly and four wore monthly soft CLs. Measurements from controls and contact lens-wearing subjects showed similar degrees of variation over time. The within-subject SD in predicted intraocular lens (IOL) power for emmetropia for contact lens wearers was 0.20 D (95% CI 0.16-0.25 D) compared to 0.18 D (95% CI 0.12-0.26 D) for controls. There is a significant variation in UK practice regarding advice on the timing of cessation of contact lens wear prior to having biometry performed. Our study suggests that it is likely that soft contact lens wearers are currently being advised to remove their contact lenses for an unnecessarily long period of time prior to having biometry performed.

  12. Impact of replacing Chinese ethnicity-specific fetal biometry charts with the INTERGROWTH-21(st) standard.

    PubMed

    Cheng, Yky; Leung, T Y; Lao, Tth; Chan, Y M; Sahota, D S

    2016-09-01

    To assess the impact of adopting the INTERGROWTH-21(st) biometry standards in a Chinese population. Retrospective cohort study. A teaching hospital in Hong Kong. A total of 10 527 Chinese women with a singleton pregnancy having a second- or third-trimester fetal anomaly or growth scan between January 2009 and June 2014. Z-scores were derived for fetal abdominal circumference (AC), head circumference (HC), and femur length (FL) using the INTERGROWTH-21(st) and Chinese biometry standards. Pregnancies with aneuploidy, structural or skeletal abnormalities, or that developed pre-eclampsia were excluded. Z-scores were stratified as <2.5th, <5th, <10th, >90th, >95th, or >97.5th percentile. Birthweight centile, adjusted for gestation and gender, was categorised as ≤3rd, 3rd to ≤5th, 5th to ≤10th, and >10th. Pairwise comparison and the McNemar test were performed to assess biometry Z-score differences and concordance between the INTERGROWTH-21(st) and Chinese standards. The sensitivity of both the local and INTERGROWTH-21(st) AC standards to identify pregnancies that were small-for-gestational-age (SGA) was assessed. INTERGROWTH-21(st) AC, HC, and FL Z-scores were significantly lower than those obtained using our local reference for AC, HC, and FL (P < 0.0001 for all). The proportion of fetuses with biometry in the <2.5th, <5th, <10th, >90th, >95th, or >97.5th percentiles was statistically significant (P < 0.01 for all). A total of 1224 (15.5%) of the scans at 18-22 weeks of gestation had AC, HC, or FL below the 3rd percentile of the INTERGROWTH-21(st) standard. Adopting the INTERGROWTH-21(st) standard would lead to a significant number of fetuses being at risk of misdiagnosis for small fetal size, particularly when using HC and FL measures. INTERGROWTH-21(st) biometry assessment in Chinese leads to fetuses being at risk of misdiagnosis of small fetal size. © 2016 Royal College of Obstetricians and Gynaecologists.

  13. Correlation between pre-pregnancy body mass index and maternal visceral adiposity with fetal biometry during the second trimester.

    PubMed

    Lopes, Karina R M; Souza, Alex Sandro R; Figueiroa, José N; Alves, João Guilherme B

    2017-08-01

    To determine the correlation between pre-pregnancy body mass index (BMI) and maternal visceral adiposity with fetal biometry during the second trimester. A cross-sectional observational study was conducted among pregnant women who received prenatal care at a center in Recife, Brazil, between October 3, 2011, and September 27, 2013. Pre-pregnancy BMI was determined at the first prenatal care visit. Maternal visceral adiposity and fetal biometry were measured at the same ultrasonography session. The associations between maternal and fetal variables were evaluated using the Pearson correlation coefficient (R). The Student t test was used to test the null hypothesis of adjusted correlation coefficients. Overall, 740 women were included. No correlation was found between pre-pregnancy BMI and any of the fetal biometric variables assessed. By contrast, maternal visceral adiposity positively correlated with fetal abdominal circumference (R=0.529), estimated fetal weight (R=0.524), head circumference (R=0.521), femur length (R=0.521), and biparietal diameter (R=0.524; P<0.001 for all fetal variables). These findings remained statistically significant after controlling for pregnancy length. Maternal visceral adiposity, but not pre-pregnancy BMI, positively correlated with fetal biometry during the second trimester. © 2017 International Federation of Gynecology and Obstetrics.

  14. Evaluation of the validity and reliability of A-scan ultrasound biometry with a single use disposable cover.

    PubMed

    Cass, K; Thompson, C M; Tromans, C; Wood, I C J

    2002-03-01

    The UK Medical Devices Agency has suggested that ophthalmic practitioners should, where practicable and not compromising clinical outcome, restrict corneal contact devices to single patient use to minimise a remote theoretical risk of transmission of new variant Creutzfeldt-Jakob disease (vCJD). This study reports on a modified technique of ultrasound A-scan biometry that complies with the MDA recommendations. The right eyes of 37 consecutive hospital patients had a series of biometry readings taken with a Humphrey 820 A-scan instrument with a plane wave transducer use d conventionally and with the addition of a disposable latex cover. Intrasessional repeatability of axial length measurements was similar for conventional readings--mean difference 0.027 mm, 95% confidence intervals (CI) +/- 0.44 mm and those taken with a disposable cover (0.028 mm, CI +/- 0.38). Intersessional repeatability was equivalent with (0.002 mm, CI +.- 0.51) and without a cover (0.03 mm, CI +/- 0.51). Readings with a cover were not significantly different from those without (paired t test; p >0.05), but tended to be greater (mean difference 0.085 mm, CI +/- 0.60). These findings suggest that corneal contact biometry with a disposable cover is a viable and theoretically safer alternative to the conventional technique.

  15. Ultrasonographic biometry of the normal eye of the Persian cat.

    PubMed

    Mirshahi, A; Shafigh, S H; Azizzadeh, M

    2014-07-01

    To describe the normal ultrasonographic biometry of the Persian cat's eyes using B-mode ultrasonography. In a cross-sectional study, 20 healthy Persian cats with no history of previous ophthalmic disease were examined. Ocular biometry of the left and right eyes was measured using B-mode ultrasonography. Comparison of the average measurements between left and right eyes and between vertical and horizontal planes was performed using paired-sample t test. Correlation of ocular parameters with sex, age, head circumference and eye colour was evaluated. Mean ± standard deviation (SD) measurements of the ocular structures of anterior chamber, lens thickness, vitreous chamber and anterior to posterior dimension of the globe in 40 eyes were 4.1 ± 0.7, 7.7 ± 0.5, 8.2 ± 0.4 and 20.7 ± 1.0 mm, respectively. No significant difference was found between the ocular biometry of the left and right eyes or the horizontal and vertical planes. Of the ocular parameters, the following had a significant positive correlation with head circumference: axial globe length, anterior chamber and lens thickness. The vitreous body had a positive correlation with age. Regarding the breed predisposition of Persian cats to ocular problems, the present study provides baseline information for further clinical investigations of ocular abnormalities using B-mode ultrasonography. © 2014 Australian Veterinary Association.

  16. Laser optical method of visualizing cutaneous blood vessels and its applications in biometry and photomedicine

    NASA Astrophysics Data System (ADS)

    Asimov, M. M.; Asimov, R. M.; Rubinov, A. N.

    2011-05-01

    We propose and examine a new approach to visualizing a local network of cutaneous blood vessels using laser optical methods for applications in biometry and photomedicine. Various optical schemes of the formation of biometrical information on the architecture of blood vessels of skin tissue are analyzed. We developed an optical model of the interaction of the laser radiation with the biological tissue and a mathematical algorithm of processing of measurement results. We show that, in medicine, the visualization of blood vessels makes it possible to calculate and determine regions of disturbance of blood microcirculation and to control tissue hypoxia, as well as to maintain the local concentration of oxygen at a level necessary for the normal cellular metabolism. We propose noninvasive optical methods for modern photomedicine and biometry for diagnostics and elimination of tissue hypoxia and for personality identification and verification via the pattern of cutaneous blood vessels.

  17. Testosterone serum profile, semen characteristics and testicular biometry of Mangalarga Marchador stallions in a tropical environment.

    PubMed

    Waddington, B; Penitente-Filho, J M; Neves, Jgs; Pinho, R O; Chaya, A Y; Maitan, P P; Silveira, C O; Neves, M G; Guimarães, Sef; de Carvalho, G R; Guimarães, J D

    2017-04-01

    This study was conducted to characterize the daily profile of testosterone secretion and its mean concentrations in the four seasons as well as to evaluate the semen characteristics and testicular biometry of Mangalarga Marchador stallions throughout the year in a tropical region. Three stallions were submitted to semen collections and evaluation of testicular biometry every 14 days along a year. Blood samples were collected once at the middle of each season, in a 20-min interval during 24 hr in order to evaluate the testosterone secretion profiles among seasons. Testosterone concentrations along the day were higher at the beginning of the afternoon (from 12:00 to 15:00 hr), but a circadian secretion was not clearly observed. Mean testosterone concentrations did not differ among seasons (p > .05), but a pattern of secretion along the day showed variations with higher concentrations in the afternoon during the winter. Ejaculate volume was higher during summer; however, sperm motility decreased in summer and spring. Total sperm in ejaculate, sperm morphology and testicular biometry kept constant along the year showing no differences among the seasons. The results demonstrated that in a tropical region, reproductive aspects of stallions did not show a clearly defined seasonal variation, and months of autumn and winter were not unsuitable for reproduction of the males. © 2017 Blackwell Verlag GmbH.

  18. Evaluation of the validity and reliability of A-scan ultrasound biometry with a single use disposable cover

    PubMed Central

    Cass, K; Thompson, C M; Tromans, C; Wood, I C J

    2002-01-01

    Background: The UK Medical Devices Agency has suggested that ophthalmic practitioners should, where practicable and not compromising clinical outcome, restrict corneal contact devices to single patient use to minimise a remote theoretical risk of transmission of new variant Creutzfeldt-Jakob disease (vCJD). This study reports on a modified technique of ultrasound A-scan biometry that complies with the MDA recommendations. Methods: The right eyes of 37 consecutive hospital patients had a series of biometry readings taken with a Humphrey 820 A-scan instrument with a plane wave transducer use d conventionally and with the addition of a disposable latex cover. Results: Intrasessional repeatability of axial length measurements was similar for conventional readings—mean difference 0.027 mm, 95% confidence intervals (CI) ± 0.44 mm and those taken with a disposable cover (0.028 mm, CI ± 0.38). Intersessional repeatability was equivalent with (0.002 mm, CI ± 0.51) and without a cover (0.03 mm, CI ± 0.51). Readings with a cover were not significantly different from those without (paired t test; p >0.05), but tended to be greater (mean difference 0.085 mm, CI ± 0.60). Conclusions: These findings suggest that corneal contact biometry with a disposable cover is a viable and theoretically safer alternative to the conventional technique. PMID:11864896

  19. The Relationship Between High-Order Aberration and Anterior Ocular Biometry During Accommodation in Young Healthy Adults

    PubMed Central

    Ke, Bilian; Mao, Xinjie; Jiang, Hong; He, Jichang; Liu, Che; Li, Min; Yuan, Ying

    2017-01-01

    Purpose This study investigated the anterior ocular anatomic origin of high-order aberration (HOA) components using optical coherence tomography and a Shack-Hartmann wavefront sensor. Methods A customized system was built to simultaneously capture images of ocular wavefront aberrations and anterior ocular biometry. Relaxed, 2-diopter (D) and 4-D accommodative states were repeatedly measured in 30 young subjects. Custom software was used to correct optical distortions and measure biometric parameters from the images. Results The anterior ocular biometry changed during 2-D accommodation, in which central lens thickness, ciliary muscle thicknesses at 1 mm posterior to the scleral spur (CMT1), and the maximum value of ciliary muscle thickness increased significantly, whereas anterior chamber depth, CMT3, radius of anterior lens surface curvature (RAL), and radius of posterior lens surface curvature (RPL) decreased significantly. The changes in the anterior ocular parameters during 4-D accommodation were similar to those for the 2-D accommodation. \\begin{document}\

  20. Assessment of femur length for fetal biometry in Malaysian pregnant women

    NASA Astrophysics Data System (ADS)

    Ramli, Ramzun Maizan; Adam, Noraina; Jaafar, Mohamad Suhaimi; Rahman, Azhar Abdul; Mustafa, Iskandar Shahrim; Radzi, Yasmin; Nordin, Suriani; Kamarudin, Izyani

    2013-05-01

    The fetal biometry assessment of femur length (FL) was developed in most countries to evaluate the foetus growth. In this study, the FL values for Malaysia population were determined. A prospective study was conducted and a number of 6501 pregnant women were involved with 12372 FL data were collected, performed at antenatal care clinic of Hospital Pulau Pinang, Malaysia. The SPSS software version 17 (regression analysis and paired sample t-test) were used for analysis. The FL values of this study were constructed and rapid FL growth rate in second trimester (2.59 mm/week) than third trimester (1.43 mm/week) was observed. By ethnicity, no significant difference (p ≥ 0.05) was found between the FL values for fetuses of Malay and Indian ethnic's mother (t = -2.042), however these two groups shows significantly (p < 0.05) higher values than those of Chinese ethnic's mother (t = 4.019, 4.083; accordingly). The FL values of Malaysian resulted as significant difference with the common reference FL values from USA and UK, and also with selected Asian populations (India, China, Korea and Japan). As conclusion, it is strong suggested that medical practitioner in Malaysia should avoid in using biometry references based on other population to avoid under- or over-estimation and for accurate assessment of the fetus growth. As this study involved local Malaysian fetuses, therefore the medical practitioner can use the FL values of this study as reference value for fetus biometry assessment in Malaysia.

  1. Diagnostic Accuracy and Clinical Implications of Translabial Ultrasound for the Assessment of Levator Ani Defects and Levator Ani Biometry in Women With Pelvic Organ Prolapse: A Systematic Review.

    PubMed

    Notten, Kim J B; Vergeldt, Tineke F M; van Kuijk, Sander M J; Weemhoff, Mirjam; Roovers, Jan-Paul W R

    The aim of this study was to assess the diagnostic accuracy and clinical implications of translabial 3-dimensional (3D) ultrasound for the assessment of levator ani defects and biometry in women with pelvic organ prolapse (POP). We performed a systematic literature search through computerized databases including MEDLINE (via PubMed), EMBASE (via OvidSP), and the Cochrane Library using both medical subject headings and text terms from January 1, 2003, to December 25, 2015.We included articles that reported on POP status and diagnostic accuracy measurements with translabial 3D ultrasound or transperineal ultrasound for the detection of levator ani defects or for measuring pelvic floor biometry, that is, levator ani hiatus, or reported on the clinical relevance of using translabial 3D ultrasound for levator ani defects or measuring pelvic floor biometry in women with POP. Thirty-one articles were selected in accordance with parts of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines that can be applied to studies of diagnostic accuracy. Twenty-two articles (71%) are coauthored by 1 expert in this field. Detecting levator ani defects with translabial 3D ultrasound compared with magnetic resonance imaging showed a moderate to good agreement, whereas measuring hiatal biometry on translabial 3D ultrasound compared with magnetic resonance imaging showed a moderate to very good agreement.The interobserver agreement for diagnosing levator ani defects and measuring the levator hiatal area showed a moderate to very good agreement. Furthermore, levator ani defects increase the risk of cystocele and uterine prolapse, and levator ani defects are associated with recurrent POP.Finally, a larger hiatus was associated with POP and recurrent POP. Translabial 3D ultrasound is reproducible for diagnosing levator ani defects and ballooning hiatus. Both levator ani defects and a larger hiatal area are, in a selected population of patients with pelvic floor dysfunction, associated with POP and recurrent POP. More research is needed concerning external validation because most data in this article are coauthored by 1 expert in this field.

  2. Biometric Changes After Trabeculectomy with Contact and Non-contact Biometry.

    PubMed

    Alvani, Azam; Pakravan, Mohammad; Esfandiari, Hamed; Yaseri, Mehdi; Yazdani, Shahin; Ghahari, Elham

    2016-02-01

    To compare biometric changes measured with contact and noncontact methods after mitomycin-C-augmented trabeculectomy. In this prospective study, 31 eyes from 31 glaucoma patients scheduled for primary trabeculectomy were enrolled. Biometric parameters including axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) were measured using contact ultrasound biometry (UD-6000 Ultrasonic A/B scanner biometer; Tomey Corporation, Nagoya, Japan) and a noncontact optical biometry device (Lenstar; Haag-Streit AG, Koeniz, Switzerland). Measurements were taken the day before trabeculectomy and then compared with measurements obtained 3 and 6 months after surgery. The AL and ACD were significantly decreased at 3 and 6 months compared with baseline values taken with each biometry method. There was a significant increase in LT measured by the Lenstar device at the 3- and 6-month follow-up. At both the 3- and 6-month follow-up, the mean AL measurement reduction with the Lenstar device was significantly lower than that of the A-scan ultrasound measurements. The mean ACD changes between the two devices were not significantly different. There is a small but significant decrease in the AL and ACD after trabeculectomy as measured with both the contact and noncontact methods. The amount of AL reduction measured is significantly smaller using the noncontact method, making it the preferable method for intraocular lens power calculation for patients who need cataract surgery combined with or after trabeculectomy. The LT measured by the Lenstar device increased significantly after the operation, which can be an early sign of the progression of cataractous changes after trabeculectomy.

  3. Does the use of automated fetal biometry improve clinical work flow efficiency?

    PubMed

    Espinoza, Jimmy; Good, Sara; Russell, Evie; Lee, Wesley

    2013-05-01

    This study was designed to compare the work flow efficiency of manual measurements of 5 fetal parameters with a novel technique that automatically measures these parameters from 2-dimensional sonograms. This prospective study included 200 singleton pregnancies between 15 and 40 weeks' gestation. Patients were randomly allocated to either manual (n = 100) or automatic (n = 100) fetal biometry. The automatic measurement was performed using a commercially available software application. A digital video recorder captured all on-screen activity associated with the sonographic examination. The examination time and number of steps required to obtain fetal measurements were compared between manual and automatic methods. The mean time required to obtain the biometric measurements was significantly shorter using the automated technique than the manual approach (P < .001 for all comparisons). Similarly, the mean number of steps required to perform these measurements was significantly fewer with automatic measurements compared to the manual technique (P < .001). In summary, automated biometry reduced the examination time required for standard fetal measurements. This approach may improve work flow efficiency in busy obstetric sonography practices.

  4. Normative biometry of the fetal brain using magnetic resonance imaging.

    PubMed

    Kyriakopoulou, Vanessa; Vatansever, Deniz; Davidson, Alice; Patkee, Prachi; Elkommos, Samia; Chew, Andrew; Martinez-Biarge, Miriam; Hagberg, Bibbi; Damodaram, Mellisa; Allsop, Joanna; Fox, Matt; Hajnal, Joseph V; Rutherford, Mary A

    2017-07-01

    The fetal brain shows accelerated growth in the latter half of gestation, and these changes can be captured by 2D and 3D biometry measurements. The aim of this study was to quantify brain growth in normal fetuses using Magnetic Resonance Imaging (MRI) and to produce reference biometry data and a freely available centile calculator ( https://www.developingbrain.co.uk/fetalcentiles/ ). A total of 127 MRI examinations (1.5 T) of fetuses with a normal brain appearance (21-38 gestational weeks) were included in this study. 2D and 3D biometric parameters were measured from slice-to-volume reconstructed images, including 3D measurements of supratentorial brain tissue, lateral ventricles, cortex, cerebellum and extra-cerebral CSF and 2D measurements of brain biparietal diameter and fronto-occipital length, skull biparietal diameter and occipitofrontal diameter, head circumference, transverse cerebellar diameter, extra-cerebral CSF, ventricular atrial diameter, and vermis height, width, and area. Centiles were constructed for each measurement. All participants were invited for developmental follow-up. All 2D and 3D measurements, except for atrial diameter, showed a significant positive correlation with gestational age. There was a sex effect on left and total lateral ventricular volumes and the degree of ventricular asymmetry. The 5th, 50th, and 95th centiles and a centile calculator were produced. Developmental follow-up was available for 73.1% of cases [mean chronological age 27.4 (±10.2) months]. We present normative reference charts for fetal brain MRI biometry at 21-38 gestational weeks. Developing growth trajectories will aid in the better understanding of normal fetal brain growth and subsequently of deviations from typical development in high-risk pregnancies or following premature delivery.

  5. Comparison of translabial three-dimensional ultrasound with magnetic resonance imaging for measurement of levator hiatal biometry at rest.

    PubMed

    Vergeldt, T F M; Notten, K J B; Stoker, J; Fütterer, J J; Beets-Tan, R G; Vliegen, R F A; Schweitzer, K J; Mulder, F E M; van Kuijk, S M J; Roovers, J P W R; Kluivers, K B; Weemhoff, M

    2016-05-01

    To compare translabial three-dimensional (3D) ultrasound with magnetic resonance imaging (MRI) for the measurement of levator hiatal biometry at rest in women with pelvic organ prolapse, and to determine the interobserver reliability between two independent observers for ultrasound and MRI measurements. Data were derived from a multicenter prospective cohort study in which women scheduled for conventional anterior colporrhaphy underwent translabial 3D ultrasound and MRI prior to surgery. Intraclass correlation coefficients (ICCs) were calculated to estimate interobserver reliability between two independent observers and determine the agreement between ultrasound and MRI measurements. Bland-Altman plots were created to assess the agreement between ultrasound and MRI measurements. Data from 139 women from nine hospitals were included in the study. The interobserver reliability of ultrasound assessment at rest, during Valsalva maneuver and during contraction and of MRI assessment at rest were moderate or good. The agreement between ultrasound and MRI for the measurement of levator hiatal biometry at rest was moderate, with ICCs of 0.52 (95%CI, 0.32-0.66) for levator hiatal area, 0.44 (95%CI, 0.21-0.60) for anteroposterior diameter and 0.44 (95%CI, 0.22-0.60) for transverse diameter. Levator hiatal biometry measurements were statistically significantly larger on MRI than on translabial 3D ultrasound. The agreement between translabial 3D ultrasound and MRI for measurement of the levator hiatus at rest in women with pelvic organ prolapse was only moderate. The results of translabial 3D ultrasound and MRI should therefore not be used interchangeably in daily practice or in clinical research. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  6. Biometric measurements in highly myopic eyes.

    PubMed

    Shen, Peiyang; Zheng, Yingfeng; Ding, Xiaohu; Liu, Bin; Congdon, Nathan; Morgan, Ian; He, Mingguang

    2013-02-01

    To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Comparative evaluation of diagnostic technology. Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥ 27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Fetal Biometry of Head Circumference for Malaysian Pregnant Women

    NASA Astrophysics Data System (ADS)

    Ramli, Remsen Maizan; Jaafar, M. S.; Ismail, N. E.; Saltani, Hend A. A.; Ahmad, A. L.; Bermakai, M. Yahaya

    2010-07-01

    The purpose of this research is to study the fetal head circumference (HC) biometry for local population. Retrospective study was selected, done at Hospital Pulau Pinang and 5551 files of pregnant women were collected. The HC mean values of this study (HCmean) was compared with other published studies to see whether there was any difference between the various populations in the world. Comparison of means, regression analysis and paired sample t-test in SPSS software version 11.5 were used in the analysis. A total of 9874 HC data (mm) were recorded for gestational age (GA) of 12 to 41 weeks. The HC growth rate in second trimester (11.32 mm/week) has decreased to nearly half than in third trimester (5.53 mm/week). The HCmean was found to be highly significant difference (SD) than other 9 studies and only lower than HC values of USA, UK and Zimbabwe populations. The HC values of German show close similarity with HCmean. From 45 comparisons done, more than three-quarter of the comparisons resulted as SD (37) compared to insignificant differences (8). Consequently, each country should have their own standard HC of fetus biometry of the various gestations for their own population.

  8. THE LAWS OF ENERGY CONSUMPTION IN NUTRITION,

    DTIC Science & Technology

    NUTRITION , THERMAL ANALYSIS), HEAT, BIOMETRY, BODY TEMPERATURE, ENERGY, LABORATORY ANIMALS, HUMANS, FOOD, CALORIMETRY, BIOCHEMISTRY, PROTEINS...DIET, METABOLISM, LOW TEMPERATURE, AGING(PHYSIOLOGY), STARVATION, MIXTURES, CLOTHING , COOLING.

  9. Comparison of immersion ultrasound, partial coherence interferometry, and low coherence reflectometry for ocular biometry in cataract patients.

    PubMed

    Montés-Micó, Robert; Carones, Francesco; Buttacchio, Antonietta; Ferrer-Blasco, Teresa; Madrid-Costa, David

    2011-09-01

    To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and anterior chamber depth between techniques. No statistically significant differences were noted for the study cohort or within each cataract degree among the three techniques for axial length and anterior chamber depth (P>.05, ANOVA test). Measurements between techniques were highly correlated for axial length (R=0.99) and anterior chamber depth (R=0.90 to 0.96) for all methods. Keratometry, flattest axis, and white-to-white measurements were comparable (paired t test, P>.1) and correlated well between partial coherence interferometry and low coherence reflectometry (K1 [R=0.95), K2 [R=0.97], flattest axis [R=0.95], and white-to-white [R=0.92]). Immersion ultrasound, partial coherence interferometry, and low coherence reflectometry provided comparable ocular biometry measurements in cataractous eyes. Copyright 2011, SLACK Incorporated.

  10. Approaches to Teaching Biometry and Epidemiology at Two Veterinary Schools in Germany.

    PubMed

    Zeimet, Ramona; Kreienbrock, Lothar; Doherr, Marcus G

    In a thematically broad and highly condensed curriculum like veterinary medicine, it is essential to pay close attention to the didactic and methodical approaches used to deliver that content. The course topics ideally should be selected for their relevance but also for the target audience and their previous knowledge. The overall objective is to improve the long-term availability of what has been learned. For this reason, an evaluation among lecturers of German-speaking veterinary schools was carried out in 2012 to consider which topics in biometry and epidemiology they found relevant to other subject areas. Based on this survey, two veterinary schools (Berlin and Hannover) developed a structured approach for the introductory course in biometry and epidemiology. By means of an appropriate choice of topics and the use of adequate teaching methods, the quality of the lecture course could be significantly increased. Appropriately communicated learning objectives as well as a high rate of student activity resulted in increased student satisfaction. A certain degree of standardization of teaching approaches and material resulted in a comparison between the study sites and reduced variability in the content delivered at different schools. Part of this was confirmed by the high consistency in the multiple-choice examination results between the study sites. The results highlight the extent to which didactic and methodical restructuring of teaching affects the learning success and satisfaction of students. It can be of interest for other courses in veterinary medicine, human medicine, and biology.

  11. Normal fetal posterior fossa in MR imaging: new biometric data and possible clinical significance.

    PubMed

    Ber, R; Bar-Yosef, O; Hoffmann, C; Shashar, D; Achiron, R; Katorza, E

    2015-04-01

    Posterior fossa malformations are a common finding in prenatal diagnosis. The objectives of this study are to re-evaluate existing normal MR imaging biometric data of the fetal posterior fossa, suggest and evaluate new parameters, and demonstrate the possible clinical applications of these data. This was a retrospective review of 215 fetal MR imaging examinations with normal findings and 5 examinations of fetuses with a suspected pathologic posterior fossa. Six previously reported parameters and 8 new parameters were measured. Three new parameter ratios were calculated. Interobserver agreement was calculated by using the intraclass correlation coefficient. For measuring each structure, 151-211 MR imaging examinations were selected, resulting in a normal biometry curve according to gestational age for each parameter. Analysis of the ratio parameters showed that vermian lobe ratio and cerebellar hemisphere ratio remain constant with gestational age and that the vermis-to-cisterna magna ratio varies with gestational age. Measurements of the 5 pathologic fetuses are presented on the normal curves. Interobserver agreement was excellent, with the intraclass correlation coefficients of most parameters above 0.9 and only 2 parameters below 0.8. The biometry curves derived from new and existing biometric data and presented in this study may expand and deepen the biometry we use today, while keeping it simple and repeatable. By applying these extensive biometric data on suspected abnormal cases, diagnoses may be confirmed, better classified, or completely altered. © 2015 by American Journal of Neuroradiology.

  12. Maternal hemodynamics, fetal biometry and Dopplers in pregnancies followed up for suspected fetal growth restriction.

    PubMed

    Roberts, Llinos A; Ling, Hua Zen; Poon, Liona; Nicolaides, Kypros H; Kametas, Nikos A

    2018-04-01

    To assess whether in a cohort of patients with small for gestational age (SGA) foetuses with estimated fetal weight ≤10 th percentile, maternal hemodynamics, fetal biometry and Dopplers at presentation, can predict the subsequent development of abnormal fetal Dopplers or delivery with birthweight <3 rd percentile. The study population comprised of 86 singleton pregnancies with SGA fetuses presenting at a median gestational age of 32 (range 26-35) weeks. We measured maternal cardiac function with a non-invasive transthoracic bioreactance monitor (NICOM, Cheetah), mean arterial pressure, fetal biometry, umbilical artery (UA), middle cerebral artery (MCA) and uterine artery (UT) pulsatility index (PI) and the deepest vertical pool (DVP) of amniotic fluid. Z-scores of these variables were calculated based on reported reference ranges and the values were compared between those with evidence of abnormal fetal Dopplers at presentation (group 1), those that developed abnormal Dopplers in subsequent visits (group 2) and those who did not develop abnormal Dopplers throughout pregnancy (group 3). Abnormal fetal Dopplers were defined as UAPI >95 th percentile, or MCA PI <5 th percentile. Differences in measured variables at presentation were also compared between pregnancies delivering a baby with birthweight <3 rd and ≥3 rd percentile. Multivariate logistic regression analysis was used to determine significant predictors of birthweight <3 rd percentile and evolution from normal fetal Dopplers to abnormal fetal Dopplers in groups 2 and 3. In the study population 14 (16%) cases were in group 1, 19 (22%) in group 2 and 53 (62%) in group 3. The birthweight was <3 rd percentile in 39 (45%) cases and ≥3 rd percentile in 47 (55%). In the study groups, compared to normal populations, there was decreased cardiac output and stroke volume and increased peripheral vascular resistance and mean arterial pressure (MAP) and the deviations from normal were most marked in group 1. Pregnancies with a birthweight <3 rd , compared to those ≥3 rd percentile, had higher deviations from normal in fetal biometry, maternal cardiac output, stroke volume, heart rate and peripheral vascular resistance and UT-PI. Multivariate logistic regression analysis demonstrated that in the prediction of birth weight ≤3 rd percentile, maternal hemodynamics provided significant improvement to the prediction provided by maternal demographics, fetal biometry and UT-PI, UA-PI and MCA-PI (difference between AUCs 0.18, 95% CI 0.06-0.29, p=0.002). In contrast, there was no significant independent contribution from maternal hemodynamics in the prediction of subsequent abnormal fetal Dopplers. In pregnancies with SGA fetuses there is decreased maternal cardiac output and stroke volume and increased peripheral vascular resistance and MAP and the deviations from normal are most marked in cases of redistribution in the fetal circulation and reduced amniotic fluid volume. This article is protected by copyright. All rights reserved.

  13. Discrepancy in fetal head biometry between ultrasound and MRI in suspected microcephalic fetuses.

    PubMed

    Yaniv, Gal; Katorza, Eldad; Tsehmaister Abitbol, Vered; Eisenkraft, Arik; Bercovitz, Ronen; Bader, Salim; Hoffmann, Chen

    2017-12-01

    Background Microcephaly is one of the most common fetal structural abnormalities, and prenatal microcephaly is considered a group I malformation of cortical development diagnosed according to ultrasound (US) skull measurements. Purpose To evaluate the agreement between fetal head US and magnetic resonance imaging (MRI) biometric measurements of suspected microcephalic fetuses. Material and Methods This institutional review board-approved retrospective study with waived informed consent included 180 pregnant women and was conducted at our medical center from March 2011 to April 2013. Biparietal diameter (BPD) and occipitofrontal diameter (OFD) results of fetal head US normograms were compared to normograms for MRI. We used Pearson and Spearman rho non-parametric correlation coefficients to assess the association between two quantitative variables, paired t-test for paired quantitative variables, and McNemar test for paired qualitative variables. Results The average BPD but not the average OFD percentiles in fetal head US differed significantly from the MRI results ( P < 0.0001). When looking at the accepted microcephaly threshold, both BPD and OFD percentiles differed significantly from MRI ( P < 0.0001 and P < 0.004, respectively). There was no correlation between US-measured skull biometry and MRI-measured brain biometry. Estimated cerebrospinal fluid volumes were significantly lower in the study group compared to 120 fetuses with normal findings in prenatal head US and MRI. Also, we have created a MRI-based normogram of fetal head circumference and gestational age. Conclusion The diagnosis of microcephaly by US alone may be insufficient and ideally should be validated by MRI before a final diagnosis is established.

  14. Sex Determination by Biometry of Anterior Features of Human Hip Bones in South Indian Population.

    PubMed

    Rajasekhar, Sssn; Vasudha, T K; Aravindhan, K

    2017-06-01

    Sex determination is the first step in establishing the identity of skeletal remains. Many studies included biometry of posterior features of hip bone. Very few studies are reported involving the biometry of anterior features of the hip bone. Anterior features of hip bone are important especially, if there is damage to the posterior features of hip bone in cases involving deliberate disfigurement of the body to resist identification of the crime in medicolegal cases. The present study was done to evaluate the effectiveness of anterior border parameters of the hip bone for prediction of sex using discriminant function analysis in South Indian population. A total of 206 dry bones were used (121 male and 85 female) and parameters like the distance between pubic tubercle and anterior rim of acetabulum, vertical acetabular diameter, transverse acetabular diameter, and the distance between pubic tubercle to highest point on the iliopubic eminence were measured using Vernier calipers. Normally distributed variables were compared using Students t-test to analyse the significance. There was significant difference between the male and female hip bones of the observed variables with p-value less than 0.05. In parameters like the distance between pubic tubercle to anterior rim of acetabulum and distance between the highest points on iliopubic eminence to pubic tubercle; the values were more in female when compared to males. In parameters like vertical and transverse acetabular diameters; the values in males were more when compared to females. These parameters of hip bone can be utilised for sex determination in South Indian population.

  15. Ocular biometry by computed tomography in different dog breeds.

    PubMed

    Chiwitt, Carolin L H; Baines, Stephen J; Mahoney, Paul; Tanner, Andrew; Heinrich, Christine L; Rhodes, Michael; Featherstone, Heidi J

    2017-09-01

    To (i) correlate B-mode ocular ultrasound (US) and computed tomography (CT) (prospective pilot study), (ii) establish a reliable method to measure the normal canine eye using CT, (iii) establish a reference guide for some dog breeds, (iv) compare eye size between different breeds and breed groups, and (v) investigate the correlation between eye dimensions and body weight, gender, and skull type (retrospective study). B-mode US and CT were performed on ten sheep cadaveric eyes. CT biometry involved 100 adult pure-bred dogs with nonocular and nonorbital disease, representing eleven breeds. Eye length, width, and height were each measured in two of three planes (horizontal, sagittal, and equatorial). B-mode US and CT measurements of sheep cadaveric eyes correlated well (0.70-0.71). The shape of the canine eye was found to be akin to an oblate spheroid (a flattened sphere). A reference guide was established for eleven breeds. Eyes of large breed dogs were significantly larger than those of medium and small breed dogs (P < 0.01), and eyes of medium breed dogs were significantly larger than those of small breed dogs (P < 0.01). Eye size correlated with body weight (0.74-0.82) but not gender or skull type. Computed tomography is a suitable method for biometry of the canine eye, and a reference guide was established for eleven breeds. Eye size correlated with breed size and body weight. Because correlation between B-mode US and CT was shown, the obtained values can be applied in the clinical setting, for example, for the diagnosis of microphthalmos and buphthalmos. © 2016 American College of Veterinary Ophthalmologists.

  16. Innovative virtual reality measurements for embryonic growth and development.

    PubMed

    Verwoerd-Dikkeboom, C M; Koning, A H J; Hop, W C; van der Spek, P J; Exalto, N; Steegers, E A P

    2010-06-01

    Innovative imaging techniques, using up-to-date ultrasonic equipment, necessitate specific biometry. The aim of our study was to test the possibility of detailed human embryonic biometry using a virtual reality (VR) technique. In a longitudinal study, three-dimensional (3D) measurements were performed from 6 to 14 weeks gestational age in 32 pregnancies (n = 16 spontaneous conception, n = 16 IVF/ICSI). A total of 125 3D volumes were analysed in the I-Space VR system, which allows binocular depth perception, providing a realistic 3D illusion. Crown-rump length (CRL), biparietal diameter (BPD), occipito-frontal diameter (OFD), head circumference (HC) and abdominal circumference (AC) were measured as well as arm length, shoulder width, elbow width, hip width and knee width. CRL, BPD, OFD and HC could be measured in more than 96% of patients, and AC in 78%. Shoulder width, elbow width, hip width and knee width could be measured in more than 95% of cases, and arm length in 82% of cases. Growth curves were constructed for all variables. Ear and foot measurements were only possible beyond 9 weeks gestation. This study provides a detailed, longitudinal description of normal human embryonic growth, facilitated by a VR system. Growth curves were created for embryonic biometry of the CRL, BPD, HC and AC early in pregnancy and also of several 'new' biometric measurements. Applying virtual embryoscopy will enable us to diagnose growth and/or developmental delay earlier and more accurately. This is especially important for pregnancies at risk of severe complications, such as recurrent late miscarriage and early growth restriction.

  17. Prevalence and risk factors for refractive errors and ocular biometry parameters in an elderly Asian population: the Singapore Longitudinal Aging Study (SLAS).

    PubMed

    Tan, C S H; Chan, Y H; Wong, T Y; Gazzard, G; Niti, M; Ng, T-P; Saw, S M

    2011-10-01

    To determine the prevalence rates of refractive errors and pattern of ocular biometry in a multi-ethnic elderly Asian population. A population-based study of 1835 residents aged 55-85 years, evaluating the refractive error and ocular biometry parameters, including axial length (AL) and anterior chamber depth. The age-standardized prevalence of myopia, hyperopia, astigmatism, and anisometropia were 30.0% (95% confidence interval (CI): 29.6, 30.4), 41.5% (95% CI: 41.1, 41.9), 43.5% (95% CI: 43.1, 44.0), and 22.1% (95% CI: 21.7, 22.4), respectively. Male gender (P=0.02), age ≥ 75 years (P=0.033), and higher educational level (P<0.001) were significantly associated with higher rates of myopia in multivariate analyses. The prevalence of astigmatism was higher in persons with diabetes (odds ratio (OR) 1.4, 95% CI: 1.03, 1.90, P=0.031). AL was longer in Chinese than other ethnic groups (23.7 vs 23.4 mm, P=0.018), and in men compared with women (24.2 vs 23.4 mm, P<0.001). AL was associated with increasing height (AL increased by 0.3 mm for every 10 cm increase in height, P<0.001). There is a high prevalence of myopia in elderly Singaporeans, consistent with trends seen in younger populations in Asia. Male gender and higher education were independent risk factors for myopia. These data suggest that higher rates of myopia in East Asians compared with Caucasians may not be a recent phenomenon.

  18. Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes

    PubMed Central

    Çınar, Yasin; Cingü, Abdullah Kürşat; Şahin, Muhammed; Yüksel, Harun; Türkcü, Fatih Mehmet; Çınar, Tuba; Çaça, İhsan

    2013-01-01

    Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were obtained using the Lenstar and US biometer to determine the reproducibility of the measurements between the two devices in keratoconic eyes. The Bland-Altman method was used to describe the agreement between the two devices. Results. The Lenstar could not measure at least one of the biometric properties in one eye and did not automatically give the corrected ACD in 2/3 of our study population. The Lenstar measured CCT (average difference 5.4 ± 19.6 µm; ICC = 0.90; P < 0.001), LT (average difference 0.13 ± 0.17 mm; ICC = 0.67; P < 0.001), and AL (average difference 0.10 ± 0.76 mm; ICC = 0.75; P < 0.001) thinner than US biometer, whereas it measured ACD (average difference 0.18 ± 0.17 mm; ICC = 0.85; P < 0.001) deeper than US biometer in keratoconic eyes. Conclusion. Although the difference between the measurements obtained using the two devices might be clinically acceptable, US biometry and Lenstar should not be used interchangeably for biometric measurements in KC patients. PMID:23986865

  19. Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes.

    PubMed

    Cınar, Yasin; Cingü, Abdullah Kürşat; Sahin, Muhammed; Sahin, Alparslan; Yüksel, Harun; Türkcü, Fatih Mehmet; Cınar, Tuba; Caça, Ihsan

    2013-01-01

    Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were obtained using the Lenstar and US biometer to determine the reproducibility of the measurements between the two devices in keratoconic eyes. The Bland-Altman method was used to describe the agreement between the two devices. Results. The Lenstar could not measure at least one of the biometric properties in one eye and did not automatically give the corrected ACD in 2/3 of our study population. The Lenstar measured CCT (average difference 5.4 ± 19.6 µm; ICC = 0.90; P < 0.001), LT (average difference 0.13 ± 0.17 mm; ICC = 0.67; P < 0.001), and AL (average difference 0.10 ± 0.76 mm; ICC = 0.75; P < 0.001) thinner than US biometer, whereas it measured ACD (average difference 0.18 ± 0.17 mm; ICC = 0.85; P < 0.001) deeper than US biometer in keratoconic eyes. Conclusion. Although the difference between the measurements obtained using the two devices might be clinically acceptable, US biometry and Lenstar should not be used interchangeably for biometric measurements in KC patients.

  20. Prediction of accommodative optical response in prepresbyopic patients using ultrasound biomicroscopy

    PubMed Central

    Ramasubramanian, Viswanathan; Glasser, Adrian

    2015-01-01

    PURPOSE To determine whether relatively low-resolution ultrasound biomicroscopy (UBM) can predict the accommodative optical response in prepresbyopic eyes as well as in a previous study of young phakic subjects, despite lower accommodative amplitudes. SETTING College of Optometry, University of Houston, Houston, USA. DESIGN Observational cross-sectional study. METHODS Static accommodative optical response was measured with infrared photorefraction and an autorefractor (WR-5100K) in subjects aged 36 to 46 years. A 35 MHz UBM device (Vumax, Sonomed Escalon) was used to image the left eye, while the right eye viewed accommodative stimuli. Custom-developed Matlab image-analysis software was used to perform automated analysis of UBM images to measure the ocular biometry parameters. The accommodative optical response was predicted from biometry parameters using linear regression, 95% confidence intervals (CIs), and 95% prediction intervals. RESULTS The study evaluated 25 subjects. Per-diopter (D) accommodative changes in anterior chamber depth (ACD), lens thickness, anterior and posterior lens radii of curvature, and anterior segment length were similar to previous values from young subjects. The standard deviations (SDs) of accommodative optical response predicted from linear regressions for UBM-measured biometry parameters were ACD, 0.15 D; lens thickness, 0.25 D; anterior lens radii of curvature, 0.09 D; posterior lens radii of curvature, 0.37 D; and anterior segment length, 0.42 D. CONCLUSIONS Ultrasound biomicroscopy parameters can, on average, predict accommodative optical response with SDs of less than 0.55 D using linear regressions and 95% CIs. Ultrasound biomicroscopy can be used to visualize and quantify accommodative biometric changes and predict accommodative optical response in prepresbyopic eyes. PMID:26049831

  1. Proceedings of the Second Biennial Southern Silvicultural Research Station Conference, Atlanta, Georgia, November 4-5, 1982

    Treesearch

    Earle P. Jones; [Editor

    1983-01-01

    86 papers are presented in 13 cateqories: Site Preparation, Prescribed Fire, Pine Regeneration, Hardwood Reqeneration, Thinning, Harvesting, Growth and Yield, Biometry, Pest Manaqement, Nursery Practices, Tree Improvement, Water, and Wildlife.

  2. Costs of cloud computing for a biometry department. A case study.

    PubMed

    Knaus, J; Hieke, S; Binder, H; Schwarzer, G

    2013-01-01

    "Cloud" computing providers, such as the Amazon Web Services (AWS), offer stable and scalable computational resources based on hardware virtualization, with short, usually hourly, billing periods. The idea of pay-as-you-use seems appealing for biometry research units which have only limited access to university or corporate data center resources or grids. This case study compares the costs of an existing heterogeneous on-site hardware pool in a Medical Biometry and Statistics department to a comparable AWS offer. The "total cost of ownership", including all direct costs, is determined for the on-site hardware, and hourly prices are derived, based on actual system utilization during the year 2011. Indirect costs, which are difficult to quantify are not included in this comparison, but nevertheless some rough guidance from our experience is given. To indicate the scale of costs for a methodological research project, a simulation study of a permutation-based statistical approach is performed using AWS and on-site hardware. In the presented case, with a system utilization of 25-30 percent and 3-5-year amortization, on-site hardware can result in smaller costs, compared to hourly rental in the cloud dependent on the instance chosen. Renting cloud instances with sufficient main memory is a deciding factor in this comparison. Costs for on-site hardware may vary, depending on the specific infrastructure at a research unit, but have only moderate impact on the overall comparison and subsequent decision for obtaining affordable scientific computing resources. Overall utilization has a much stronger impact as it determines the actual computing hours needed per year. Taking this into ac count, cloud computing might still be a viable option for projects with limited maturity, or as a supplement for short peaks in demand.

  3. Intraoperative aberrometry-based aphakia refraction in patients with cataract: status and options.

    PubMed

    Huelle, Jan O; Druchkiv, Vasyl; Habib, Nabil E; Richard, Gisbert; Katz, Toam; Linke, Stephan J

    2017-02-01

    To explore the application of intraoperative wavefront aberrometry (IWA) for aphakia-based biometry using three existing formulae derived from autorefractive retinoscopy and introducing new improved formulae. In 74 patients undergoing cataract surgery, three repeated measurements of aphakic spherical equivalent (SE) were taken. All measurements were objectively graded for their quality and evaluated with the 'limits of agreement' approach. ORs were calculated and analysis of variance was applied. The intraocular lens (IOL) power that would have given the target refraction was back-calculated from manifest refraction at 3 months postoperatively. Regression analysis was performed to generate two aphakic SE-based formulae for predicting this IOL. The accuracy of the formulae was determined by comparing them to conventional biometry and published aphakia formulae. In 32 eyes, three consecutive aphakic measurements were successful. Objective parameters of IWA map quality significantly impacted measurement variability (p<0.05). The limits of agreement of repeated aphakic SE readings were +0.66 dioptre (D) and -0.69 D. Intraoperative biometry by our formula resulted in 25% and 53% of all cases ±0.50D and ±1.00 D within SE target, respectively. A second formula that took axial length (AL) into account resulted in improved ratios of 41% and 70%, respectively. A reliable application of IWA to calculate IOL power during routine cataract surgery may not be feasible given the high rate of measurement failures and the large variations of the readings. To enable reliable IOL calculation from IWA, measurement precision must be improved and aphakic IOL formulae need to be fine-tuned. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Usability of virtual-reality simulation training in obstetric ultrasonography: a prospective cohort study.

    PubMed

    Burden, C; Preshaw, J; White, P; Draycott, T J; Grant, S; Fox, R

    2013-08-01

    To assess the usability of virtual-reality (VR) simulation for obstetric ultrasound trainees. Twenty-six participants were recruited: 18 obstetric ultrasound trainees (with little formal ultrasonography training) and eight certified experts. All performed five sequential VR-simulated crown-rump length (CRL) scans in a single session and three repetitions of biparietal diameter (BPD), occipitofrontal diameter (OFD) and femur length (FL) measurements. Outcome measures included mean percentage deviation from target for all measurements. Time taken to perform each type of scan was recorded. The mean percentage difference for the first scan was significantly greater for the trainee group than for the expert group for BPD (P = 0.035), OFD (P = 0.010) and FL (P = 0.008) and for time taken for the first CRL (P < 0.001) and fetal biometry (including BPD, OFD and FL measurements) scan (P < 0.001), demonstrating that trainees were initially significantly less accurate and less efficient. Over subsequent scans, the trainees became more accurate for all measurements with a significant improvement shown for OFD and FL (P < 0.05). The time taken for trainees to complete CRL and fetal biometry scans decreased significantly (all P < 0.05) with repetition, to near-expert efficiency. All participants were able to use the simulator and produce clinically meaningful biometry results. With repetition, beginners quickly approached near-expert levels of accuracy and speed. These data demonstrate that obstetricians with minimal experience can improve their ultrasonographic skills with short-phase VR-simulation training. The speed of improvement suggests that VR simulation might be useful as a warm-up exercise before clinical training sessions in order to reduce their impact on clinical service. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  5. Changes in ocular biometry and anterior chamber parameters after pharmacologic mydriasis and peripheral iridotomy in primary angle closure suspects.

    PubMed

    Razeghinejad, Mohammad Reza; Lashkarizadeh, Hamid; Nowroozzadeh, Mohammad Hossein; Yazdanmehr, Mohammad

    2016-01-01

    The aim of this study was to evaluate the effects of pharmacologic mydriasis and Peripheral Iridotomy (PI) on ocular biometry and anterior chamber parameters in primary angle closure suspects. In this prospective interventional case series, 21 primary angle closure suspects were enrolled. Intraocular pressure, refraction, ocular biometry (Lenstar, LS900), and anterior chamber parameters (Pentacam HR) were measured at four occasions: before PI (before and after mydriasis with phenylephrine) and two weeks after PI (before and after mydriasis). The study was conducted on both eyes and only one eye per patient, in random, was included in the analysis. The mean age of the participants was 60±7 years and 17 (81%) were female. There were no significant differences in intraocular pressure, refraction, keratometry, biometric and anterior chamber parameters between groups, except for anterior chamber volume, which showed increments with PI and mydriasis. The corresponding values for anterior chamber volume were as follows: 88.2±13.7mm(3) before PI, undilated; 106.3±18.8 before PI, dilated; 99.0±14.6 after PI, undilated, and 107.4±16.5 after PI, dilated (P<0.001). This study showed no change in the ocular biometric and anterior chamber parameters including iridocorneal angle after PI and/or pharmacologic mydriasis except for increments in anterior chamber volume. This factor has the potential to be used as a numerical proxy for iris position in evaluating and monitoring patients with primary angle closure suspects after PI. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  6. Prevalence and risk factors for refractive errors and ocular biometry parameters in an elderly Asian population: the Singapore Longitudinal Aging Study (SLAS)

    PubMed Central

    Tan, C S H; Chan, Y H; Wong, T Y; Gazzard, G; Niti, M; Ng, T-P; Saw, S M

    2011-01-01

    Purpose To determine the prevalence rates of refractive errors and pattern of ocular biometry in a multi-ethnic elderly Asian population. Methods A population-based study of 1835 residents aged 55–85 years, evaluating the refractive error and ocular biometry parameters, including axial length (AL) and anterior chamber depth. Results The age-standardized prevalence of myopia, hyperopia, astigmatism, and anisometropia were 30.0% (95% confidence interval (CI): 29.6, 30.4), 41.5% (95% CI: 41.1, 41.9), 43.5% (95% CI: 43.1, 44.0), and 22.1% (95% CI: 21.7, 22.4), respectively. Male gender (P=0.02), age ≥75 years (P=0.033), and higher educational level (P<0.001) were significantly associated with higher rates of myopia in multivariate analyses. The prevalence of astigmatism was higher in persons with diabetes (odds ratio (OR) 1.4, 95% CI: 1.03, 1.90, P=0.031). AL was longer in Chinese than other ethnic groups (23.7 vs23.4 mm, P=0.018), and in men compared with women (24.2 vs23.4 mm, P<0.001). AL was associated with increasing height (AL increased by 0.3 mm for every 10 cm increase in height, P<0.001). Conclusion There is a high prevalence of myopia in elderly Singaporeans, consistent with trends seen in younger populations in Asia. Male gender and higher education were independent risk factors for myopia. These data suggest that higher rates of myopia in East Asians compared with Caucasians may not be a recent phenomenon. PMID:21720418

  7. Effect of supplementary implantation of a sulcus-fixated intraocular lens in patients with negative dysphotopsia.

    PubMed

    Makhotkina, Natalia Y; Dugrain, Vincent; Purchase, Daniel; Berendschot, Tos T J M; Nuijts, Rudy M M A

    2018-02-01

    To evaluate whether the outcome of negative dysphotopsia treatment by implantation of a Sulcoflex intraocular lens (IOL) can be understood using individual biometry and optical modeling data. University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands. Retrospective case series. Patients with negative dysphotopsia were treated with supplementary implantation of a sulcus-fixated IOL. Preoperative and postoperative ray-tracing optical models of eyes with negative dysphotopsia were constructed in the Zemax Optic Studio program using individual biometric data. The relationship between biometric parameters, ray-tracing data, and the course of negative dysphotopsia was evaluated. The study comprised 8 patients (10 eyes). After surgery, negative dysphotopsia resolved completely in 6 eyes, partially in 2 eyes, and persisted in 2 eyes. There was no relationship between the course of negative dysphotopsia and age, IOL power, or individual biometry results other than a larger angle κ that was observed in 2 patients with persistent negative dysphotopsia after surgery. Preoperative ray-tracing models showed a decrease in light irradiance at the periphery relative to the center of visual field. After sulcus-fixated IOL implantation, this decrease partially resolved, in particular, for a small pupil aperture (P < .05), and it was more prominent in patients in whom negative dysphotopsia resolved completely than in those with partial or persistent negative dysphotopsia (P = .065 at 1.5 mm aperture). Of all individual biometry results, only angle κ showed a relationship with the course of negative dysphotopsia. In patient-specific optical modeling of sulcus-fixated IOL implantation, the increase in simulated light irradiance at the periphery was related to the course of negative dysphotopsia. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

    PubMed

    Kaswin, Godefroy; Rousseau, Antoine; Mgarrech, Mohamed; Barreau, Emmanuel; Labetoulle, Marc

    2014-04-01

    To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Paris, France. Evaluation of a diagnostic device. One eye of consecutive patients scheduled for cataract surgery was measured. Biometry was performed with the new biometer and the reference biometer. Comparisons were performed for AL, average K at 2.4 mm, ACD, IOL power calculations with the Haigis and SRK/T formulas, and postoperative predictability of the devices. A P value less than 0.05 was statistically significant. The study enrolled 50 patients (mean age 72.6 years±4.2 SEM). There was a good correlation between biometers for AL, K, and ACD measurements (r=0.999, r=0.933, and r=0.701, respectively) and between IOL power calculation with the Haigis formula (r=0.972) and the SRK/T formula (r=0.981). The mean absolute error (MAE) in IOL power prediction was 0.42±0.08 diopter (D) with the new biometer and 0.44±0.08 D with the reference biometer. The MAE was 0.20 D with the Haigis formula and 0.19 with the SRK/T formula (P=.36). The new PCI biometer provided valid measurements compared with the current gold standard, indicating that the new device can be used for IOL power calculations for routine cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Biometry and spectral domain optical coherence tomography parameters in children with large cupping.

    PubMed

    Jung, Jong Jin; Baek, Seung-Hee; Kim, Ungsoo Samuel

    2013-09-01

    The purpose of this study is to investigate optic nerve head using spectral domain optical coherence tomography (SD-OCT) in children with large cupping. 111 eyes (4-10 years) were divided into three groups according to the cup to disc ratio: group 1, ≤0.3; group 2, 0.4-0.6; and group 3, ≥0.7. The rim area, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume were investigated using SD-OCT (Cirrus HD-OCT, Carl Zeiss, Jena, Germany), and the axial length and anterior chamber depth (ACD) were measured by IOL master (IOL master 500, Carl Zeiss, Jena, Germany). Next, we compared ocular biometry and SD-OCT between the three groups. The mean age of group 1 was 6.48 ± 1.42 years, 7.00 ± 1.75 years in group 2, and 6.63 ± 1.82 years in group 3 (p = 0.370). A significant difference was seen in the spherical equivalent between the groups (p = 0.001). Group 2 had the most myopic refractive errors. As the cup to disc ratio increases, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume increase significantly. When the results of ocular biometry and SD-OCT are adjusted for axial length, only disc area showed a significant correlation with cup to disc ratio (ACD: p = 0.473, rim area: p = 0.639, disc area: p = 0.005, and cup volume: p = 0.325). Axial length is the key factor determining disc size, which in turn is important for determining cup to disc ratio. Normal children with large cupping should be examined for axial length, myopic refractive errors, and disc size.

  10. Iris concavity, corneal biomechanics, and their correlations with ocular biometry in a cohort of 10- to 12-year-old UK school boys: baseline data.

    PubMed

    Shah, Ameet; Low, Sancy; Garway-Heath, David F; Foster, Paul J; Barton, Keith

    2014-04-17

    Pigment dispersion syndrome is associated with iris concavity. This study investigated the prevalence of iris concavity, defined as a measurement of ≤-0.1 mm, in a cohort of 10- to 12-year-old boys, and explored the relationship between iris curvature and anterior segment biometry. Associations with corneal biomechanical parameters also were explored. A cohort of school boys (n = 96) was recruited from a local school. Anterior segment optical coherence tomography (AS-OCT) was performed under accommodative and nonaccommodative conditions, and iris curvature quantified. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured with the ocular response analyzer (ORA). Noncontact axial biometry was performed using laser interferometry. The prevalence of iris concavity was 24% on distance fixation, increasing to 65% on accommodation. Variables significantly associated with nonaccommodating iris curvature were lens vault (P = 0.02) and mean keratometry (P = 0.02). For both variables acting jointly, R(2) = 0.30. Variables associated significantly with accommodating iris curvature were anterior chamber depth (P = 0.009), lens vault (P = 0.049), and mean scleral spur angle (P < 0.0001). For these three variables acting jointly, R(2) = 0.33. Significant association was found between CH and spur-to-spur distance (R(2) = 0.07, P = 0.025). Iris concavity was a common finding in this cohort and related to anterior segment biometric parameters. Further work is required to clarify whether anatomical differences exist between iris concavity seen in the adolescent eye and that found in adults with pigment dispersion syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  11. The relationship between human placental morphometry and ultrasonic measurements of utero-placental blood flow and fetal growth.

    PubMed

    Salavati, N; Sovio, U; Mayo, R Plitman; Charnock-Jones, D S; Smith, G C S

    2016-02-01

    Ultrasonic fetal biometry and arterial Doppler flow velocimetry are widely used to assess the risk of pregnancy complications. There is an extensive literature on the relationship between pregnancy outcomes and the size and shape of the placenta. However, ultrasonic fetal biometry and arterial Doppler flow velocimetry have not previously been studied in relation to postnatal placental morphometry in detail. We conducted a prospective cohort study of nulliparous women in The Rosie Hospital, Cambridge (UK). We studied a group of 2120 women who had complete data on uterine and umbilical Doppler velocimetry and fetal biometry at 20, 28 and 36 weeks' gestational age, digital images of the placenta available, and delivered a liveborn infant at term. Associations were expressed as the difference in the standard deviation (SD) score of the gestational age adjusted ultrasound measurement (z-score) comparing the lowest and highest decile of the given placental morphometric measurement. The lowest decile of placental surface area was associated with 0.87 SD higher uterine artery Doppler mean pulsatility index (PI) at 20 weeks (95% CI: 0.68 to 1.07, P < 0.001). The lowest decile of placental weight was associated with 0.73 SD higher umbilical artery Doppler PI at 36 weeks (95% CI: 0.54 to 0.93, P < 0.001). The lowest decile of both placental weight and placental area were associated with reduced growth velocity of the fetal abdominal circumference between 20 and 36 weeks (both P < 0.001). Placental area and weight are associated with uterine and umbilical blood flow, respectively, and both are associated with fetal growth rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Modeling In-Vehicle Reaches Perturbed by Ride Motion

    DTIC Science & Technology

    2004-03-14

    Human Factors and Ergonomics Society, Denver, CO. 13. Schmidt, R.A. (1987) Motor control and learning: A behavioral emphasis, 2nd ed. Human ... Kinetics : Champaign, IL. 14. Sokal, R.R., Rohlf, F.J. (1981) Biometry, Freeman: San Francisco, CA. CONTACT Please use the following contact regarding

  13. Scientific Research in British Universities and Colleges 1969-70, Volume I, Physical Sciences.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    This annual publication (1969-1970) contains brief statements about current research in the physical sciences being conducted at British universities and colleges. Areas included are chemistry, physics, engineering, biochemistry, biometry, biophysics, physical geography, mathematics, computing science, and history and philosophy of science. (CP)

  14. The Wireless Ubiquitous Surveillance Testbed

    DTIC Science & Technology

    2003-03-01

    c. Eye Patterns.............................................................................17 d. Facial Recognition ..................................................................19...27). ...........................................98 Table F.4. Facial Recognition Products. (After: Polemi, p. 25 and BiometriTech, 15 May 2002...it applies to homeland security. C. RESEARCH TASKS The main goals of this thesis are to: • Set up the biometric sensors and facial recognition surveillance

  15. Biometry Staff | Division of Cancer Prevention

    Cancer.gov

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  16. 78 FR 17219 - National Institute of Environmental Health Sciences; Notice of Closed Meeting Pursuant to section...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... Health Sciences Special Emphasis Panel, Assessment of Adverse Genetic Effects From Exposure to Compounds... Program Nos. 93.115, Biometry and Risk Estimation--Health Risks from Environmental Exposures; 93.142... Research and Testing, National Institutes of Health, HHS) Dated: March 14, 2013. Carolyn Baum, Program...

  17. Biometry Meetings and Events | Division of Cancer Prevention

    Cancer.gov

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  18. Biometric identification of capillariid eggs from archaeological sites in Patagonia.

    PubMed

    Taglioretti, V; Fugassa, M H; Beltrame, M O; Sardella, N H

    2014-06-01

    Numerous eggs of capillariid nematodes have been found in coprolites from a wide range of hosts and in raptor pellets in archaeological samples from Patagonia. The structure and sculpture of the eggshell of these nematodes and their biometry are commonly used for identification. The aim of this study was to determine whether eggs of the genus Calodium with similar morphology, found in different archaeological samples from Patagonia, belong to the same species. For this purpose, capillariid eggs (N= 843) with thick walls and radial striations were studied by permutational multivariate analysis of variance (PERMANOVA). Eggs exhibiting similar shape and structure also showed similar biometry, regardless of the zoological origin of coprolites (P= 0.84), host diet (P= 0.19), character of the archaeological sites (P= 0.67) and chronology (P= 0.66). Thus, they were attributed to the same species. We suggest that an unidentified zoonotic species of the genus Calodium occurred in the digestive tract of a wide range of hosts in Patagonia during the Holocene and that both human and animal populations were exposed to this parasite during the Holocene in the study area.

  19. François Pourfour du Petit (1664-1741): pioneer in ocular biometry.

    PubMed

    Charman, W Neil

    2016-07-01

    To outline the important contributions of the French physician Petit to the development of ocular biometry. After a brief review of Petit's life and his studies in neurology, anatomy, and cataract surgery, the methodology and results of his work in measuring many of the biometric parameters of the human eye are discussed. Among other techniques, he made use of frozen sections of eyes to explore their dimensions and employed an immersion technique to avoid the effect of corneal refraction on the appearance of the iris. His pioneering biometric results have been largely confirmed by modern studies. Those on the changes in the crystalline lens with age are particularly striking and suggest that these ocular aging effects have changed little over the last 300 years. Although largely forgotten today, his biometric work exercised a considerable influence on his more immediate successors, including Porterfield and Thomas Young. François Pourfour du Petit deserves to be remembered as an important contributor to our understanding of the structure and dimensions of the human eye. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  20. Evidence of second-trimester changes in head biometry and brain perfusion in fetuses with congenital heart disease.

    PubMed

    Masoller, N; Martínez, J M; Gómez, O; Bennasar, M; Crispi, F; Sanz-Cortés, M; Egaña-Ugrinovic, G; Bartrons, J; Puerto, B; Gratacós, E

    2014-08-01

    To evaluate the associations between congenital heart disease (CHD) and head biometry and cerebrovascular blood flow dynamics at the time of diagnosis of CHD in the second trimester of pregnancy. This was a study of 95 consecutive fetuses diagnosed with CHD. At the time of diagnosis, fetal biometry was performed and brain perfusion was assessed by middle cerebral artery pulsatility index (MCA-PI), cerebroplacental ratio (CPR) and fractional moving blood volume (FMBV). The results were compared with those of 95 normal fetuses matched for gestational age. Median gestational age at diagnosis was 22 + 3 (range, 20 + 0 to 23 + 5) weeks. Fetuses with CHD showed significantly lower MCA-PI and CPR Z-scores (-0.23 vs 0.34 and -0.37 vs 0.30, respectively; both P < 0.001) and higher FMBV Z-scores (2.35 vs 0.15; P < 0.001). FMBV > 95(th) percentile was observed in 81.1% of cases as compared with 10.5% in controls (P < 0.001). Moreover, cases showed significantly smaller biparietal diameter (BPD) and head circumference (HC) Z-scores (-1.61 vs -0.43 and -0.89 vs 0.09, respectively; both P < 0.001), with a higher proportion of BPD and HC measurements below the 5(th) percentile compared with controls (51.6% vs 13.7% and 26.3% vs 4.2%, respectively; both P < 0.001). These findings were more pronounced in those cases with types of CHD associated with compromised oxygenated blood delivery to the brain, such as left outflow tract obstruction and transposition of the great arteries. A high proportion of fetuses with CHD have a smaller head and increased brain perfusion already in the second trimester, suggesting an early onset of the mechanisms leading to poorer neurodevelopment later in life. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  1. Mid-gestation brain Doppler and head biometry in fetuses with congenital heart disease predict abnormal brain development at birth.

    PubMed

    Masoller, N; Sanz-CortéS, M; Crispi, F; Gómez, O; Bennasar, M; Egaña-Ugrinovic, G; Bargalló, N; Martínez, J M; Gratacós, E

    2016-01-01

    Fetuses with congenital heart disease (CHD) show evidence of abnormal brain development before birth, which is thought to contribute to adverse neurodevelopment during childhood. Our aim was to evaluate whether brain development in late pregnancy can be predicted by fetal brain Doppler, head biometry and the clinical form of CHD at the time of diagnosis. This was a prospective cohort study including 58 fetuses with CHD, diagnosed at 20-24 weeks' gestation, and 58 normal control fetuses. At the time of diagnosis, we recorded fetal head circumference (HC), biparietal diameter, middle cerebral artery pulsatility index (MCA-PI), cerebroplacental ratio (CPR) and brain perfusion by fractional moving blood volume. We classified cases into one of two clinical types defined by the expected levels (high or low) of placental (well-oxygenated) blood perfusion, according to the anatomical defect. All fetuses underwent subsequent 3T-magnetic resonance imaging (MRI) at 36-38 weeks' gestation. Abnormal prenatal brain development was defined by a composite score including any of the following findings on MRI: total brain volume <  10(th) centile, parietoccipital or cingulate fissure depth <  10(th) centile or abnormal metabolic profile in the frontal lobe. Logistic regression analysis demonstrated that MCA-PI (odds ratio (OR), 12.7; P = 0.01), CPR (OR, 8.7; P = 0.02) and HC (OR, 6.2; P = 0.02) were independent predictors of abnormal neurodevelopment; however, the clinical type of CHD was not. Fetal brain Doppler and head biometry at the time of CHD diagnosis are independent predictors of abnormal brain development at birth, and could be used in future algorithms to improve counseling and targeted interventions. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  2. Comparison of anterior chamber depth measurements by 3-dimensional optical coherence tomography, partial coherence interferometry biometry, Scheimpflug rotating camera imaging, and ultrasound biomicroscopy.

    PubMed

    Nakakura, Shunsuke; Mori, Etsuko; Nagatomi, Nozomi; Tabuchi, Hitoshi; Kiuchi, Yoshiaki

    2012-07-01

    To evaluate the congruity of anterior chamber depth (ACD) measurements using 4 devices. Saneikai Tsukazaki Hospital, Himeji City, Japan. Comparative case series. In 1 eye of 42 healthy participants, the ACD was measured by 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT), partial coherence interferometry (PCI), Scheimpflug imaging, and ultrasound biomicroscopy (UBM). The differences between the measurements were evaluated by 2-way analysis of variance and post hoc analysis. Agreement between the measurements was evaluated using Bland-Altman analysis. To evaluate the true ACD using PCI, the automatically calculated ACD minus the central corneal thickness measured by CAS-OCT was defined as PCI true. Two ACD measurements were also taken with CAS-OCT. The mean ACD was 3.72 mm ± 0.23 (SD) (PCI), 3.18 ± 0.23 mm (PCI true), 3.24 ± 0.25 mm (Scheimpflug), 3.03 ± 0.25 mm (UBM), 3.14 ± 0.24 mm (CAS-OCT auto), and 3.12 ± 0.24 mm (CAS-OCT manual). A significant difference was observed between PCI biometry, Scheimpflug imaging, and UBM measurements and the other methods. Post hoc analysis showed no significant differences between PCI true and CAS-OCT auto or between CAS-OCT auto and CAS-OCT manual. Strong correlations were observed between all measurements; however, Bland-Altman analysis showed good agreement only between PCI true and Scheimpflug imaging and between CAS-OCT auto and CAS OCT manual. The ACD measurements obtained from PCI biometry, Scheimpflug imaging, CAS-OCT, and UBM were significantly different and not interchangeable except for PCI true and CAS-OCT auto and CAS-OCT auto and CAS-OCT manual. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. [Can the scattering of differences from the target refraction be avoided?].

    PubMed

    Janknecht, P

    2008-10-01

    We wanted to check how the stochastic error is affected by two lens formulae. The power of the intraocular lens was calculated using the SRK-II formula and the Haigis formula after eye length measurement with ultrasound and the IOL Master. Both lens formulae were partially derived and Gauss error analysis was used for examination of the propagated error. 61 patients with a mean age of 73.8 years were analysed. The postoperative refraction differed from the calculated refraction after ultrasound biometry using the SRK-II formula by 0.05 D (-1.56 to + 1.31, S. D.: 0.59 D; 92 % within +/- 1.0 D), after IOL Master biometry using the SRK-II formula by -0.15 D (-1.18 to + 1.25, S. D.: 0.52 D; 97 % within +/- 1.0 D), and after IOL Master biometry using the Haigis formula by -0.11 D (-1.14 to + 1.14, S. D.: 0.48 D; 95 % within +/- 1.0 D). The results did not differ from one another. The propagated error of the Haigis formula can be calculated according to DeltaP = square root (deltaL x (-4.206))(2) + (deltaVK x 0.9496)(2) + (DeltaDC x (-1.4950))(2). (DeltaL: error measuring axial length, DeltaVK error measuring anterior chamber depth, DeltaDC error measuring corneal power), the propagated error of the SRK-II formula according to DeltaP = square root (DeltaL x (-2.5))(2) + (DeltaDC x (-0.9))(2). The propagated error of the Haigis formula is always larger than the propagated error of the SRK-II formula. Scattering of the postoperative difference from the expected refraction cannot be avoided completely. It is possible to limit the systematic error by developing complicated formulae like the Haigis formula. However, increasing the number of parameters which need to be measured increases the dispersion of the calculated postoperative refraction. A compromise has to be found, and therefore the SRK-II formula is not outdated.

  4. Development of the Fetal Vermis: New Biometry Reference Data and Comparison of 3 Diagnostic Modalities-3D Ultrasound, 2D Ultrasound, and MR Imaging.

    PubMed

    Katorza, E; Bertucci, E; Perlman, S; Taschini, S; Ber, R; Gilboa, Y; Mazza, V; Achiron, R

    2016-07-01

    Normal biometry of the fetal posterior fossa rules out most major anomalies of the cerebellum and vermis. Our aim was to provide new reference data of the fetal vermis in 4 biometric parameters by using 3 imaging modalities, 2D ultrasound, 3D ultrasound, and MR imaging, and to assess the relation among these modalities. A retrospective study was conducted between June 2011 and June 2013. Three different imaging modalities were used to measure vermis biometry: 2D ultrasound, 3D ultrasound, and MR imaging. The vermian parameters evaluated were the maximum superoinferior diameter, maximum anteroposterior diameter, the perimeter, and the surface area. Statistical analysis was performed to calculate centiles for gestational age and to assess the agreement among the 3 imaging modalities. The number of fetuses in the study group was 193, 172, and 151 for 2D ultrasound, 3D ultrasound, and MR imaging, respectively. The mean and median gestational ages were 29.1 weeks, 29.5 weeks (range, 21-35 weeks); 28.2 weeks, 29.05 weeks (range, 21-35 weeks); and 32.1 weeks, 32.6 weeks (range, 27-35 weeks) for 2D ultrasound, 3D ultrasound, and MR imaging, respectively. In all 3 modalities, the biometric measurements of the vermis have shown a linear growth with gestational age. For all 4 biometric parameters, the lowest results were those measured by MR imaging, while the highest results were measured by 3D ultrasound. The inter- and intraobserver agreement was excellent for all measures and all imaging modalities. Limits of agreement were considered acceptable for clinical purposes for all parameters, with excellent or substantial agreement defined by the intraclass correlation coefficient. Imaging technique-specific reference data should be used for the assessment of the fetal vermis in pregnancy. © 2016 by American Journal of Neuroradiology.

  5. Production of Doctorates in the Biosciences, 1975-1980: An Experimental Forecast. Higher Education Panel Reports, No. 34.

    ERIC Educational Resources Information Center

    Atelsek, Frank J.; Gomberg, Irene L.

    A survey was undertaken in 1976 to obtain short-term estimates of doctorate production directly from the heads of the science departments involved. These biosciences departments were surveyed in the 235 member institutions of the Higher Education Panel that grant doctorates: anatomy, biochemistry, biology, biometry/biostatistics/biomathematics,…

  6. Calculation of crystalline lens power in chickens with a customized version of Bennett's equation.

    PubMed

    Iribarren, Rafael; Rozema, Jos J; Schaeffel, Frank; Morgan, Ian G

    2014-03-01

    This paper customizes Bennett's equation for calculating lens power in chicken eyes from refraction, keratometry and biometry. Previously published data on refraction, corneal power, anterior chamber depth, lens thickness, lens radii of curvature, axial length and eye power in chickens aged 10-90 days were used to estimate Gullstrand's lens power and Bennett's lens power for chicken eyes, and to calculate the lens equivalent refractive index. Bennett's A and B constants for the front and back surface powers of the lens were calculated for data measured from day 10 to 90 at 10 day intervals, and mean customized constants were calculated. The mean customized constants for Bennett's equation for chicks were A=0.574±0.023 and B=0.379±0.021. As found previously, lens power decreases with age in chicks, while corneal power decreases and axial length increases. The lens equivalent refractive index decreases with age from 10 to 90 days after hatching. Bennett's equation can be used to calculate lens power in chicken eyes for studies on animal myopia, using standard biometry. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. The Correlation between Angle Kappa and Ocular Biometry in Koreans

    PubMed Central

    Choi, Se Rang

    2013-01-01

    Purpose To investigate normative angle kappa data and to examine whether correlations exist between angle kappa and ocular biometric measurements (e.g., refractive error, axial length) and demographic features in Koreans. Methods Data from 436 eyes (213 males and 223 females) were analyzed in this study. The angle kappa was measured using Orbscan II. We used ocular biometric measurements, including refractive spherical equivalent, interpupillary distance and axial length, to investigate the correlations between angle kappa and ocular biometry. The IOL Master ver. 5.02 was used to obtain axial length. Results The mean patient age was 57.5 ± 12.0 years in males and 59.4 ± 12.4 years in females (p = 0.11). Angle kappa averaged 4.70 ± 2.70 degrees in men and 4.89 ± 2.14 degrees in women (p = 0.48). Axial length and spherical equivalent were correlated with angle kappa (r = -0.342 and r = 0.197, respectively). The correlation between axial length and spherical equivalent had a negative correlation (r = -0.540, p < 0.001). Conclusions Angle kappa increased with spherical equivalent and age. Thus, careful manipulation should be considered in older and hyperopic patients when planning refractive or strabismus surgery. PMID:24311927

  8. The relation between fetal nasal bone length and biparietal diameter in the Korean population.

    PubMed

    Shin, Joong Sik; Yang, Jae Hyug; Chung, Jin Hoon; Kim, Moon Young; Ryu, Hyun Mee; Han, Jung Yeol; Choi, June Seek

    2006-04-01

    To evaluate the relation between fetal nasal bone length (NBL) and biparietal diameter (BPD) at 15-19.9 (20) weeks of gestation by ultrasonography in the Korean population. The study population included 1268 Korean women (aged between 19 and 45 years) with a singleton pregnancy who registered at the Maternal Fetal Medicine Unit of Samsung Cheil Hospital between September 2003 and February 2005. Ultrasound measurements of NBL were performed using a strict sagittal plan of the fetal head. Other fetal biometry profiles were conducted before amniocentesis for fetal karyotyping. NBL and fetal biometry profiles were measured successfully in 77.9% (988/1268) of the fetuses. NBL was found to increase linearly as a function of BPD (P < 0.001) with a median NBL of 4.4 mm (range 1.9-7.9). NBL increases through 15-19.9 (20) weeks of gestation were given by the equation NBL (mm) = 0.0836 x BPD (mm) + 1.368 (R2 = 0.1, P < 0.001). Fetal NBL and BPD are linearly related in the second trimester. Fetal NBL in the Korean population is likely to be shorter than that reported for Caucasians and African-Americans. Copyright 2006 John Wiley & Sons, Ltd.

  9. How close are we? An audit of biometry of a tertiary care hospital in Karachi.

    PubMed

    Siddiqui, Abdul Hameed; Khan, Maria; Hussain, Marium

    2018-01-01

    To evaluate the accuracy of biometry in the post-op phase of cataract surgery. This study was conducted at Liaquat National Hospital, Karachi, from June 2015 to July 2016, and comprised the audit of patients who underwent cataract surgery during the period. Keratometry was done on Haag-Strait manual keratometer and A-scan was done by applanation contact method on SonoMed machine. Theoretic-T formula was used to calculate desired intraocular lens power for all kinds of axial lengths. A single surgeon operated upon the same Alcon Constellation phacoemulsification machine. Postoperative follow-up was done by monitoring auto refraction and visual acuity on days 1, 7, 30 and 90. SPSS 21 was used for data analysis.. Of 244 patients, 121(49.60%) were males and 123(50.40%) were females. There were 123(50.40%) right eyes and 121(49.60%) left eyes. Overall, 132(54.10%) achieved postoperative refraction within ±0.5 D of target and 193(79.10%) within ±1 D of target. Age, gender and laterality had no significant effect on outcomes (p>0.05 each). Postoperative refraction corresponded quite closely with global recommendations.

  10. Rabbits' eye globe sonographic biometry.

    PubMed

    Toni, Maria Carolina; Meirelles, Adriana Érica Wilkes Burton; Gava, Fábio Nelson; Camacho, Aparecido Antônio; Laus, José Luiz; Canola, Júlio Carlos

    2010-11-01

    To measure intraocular structures in New Zealand White breed rabbits (Oryctolagus cuniculus Linnaeus, 1758) using A-mode and B-mode ultrasound with a 20 MHz transducer. In this study, the eyes of 15 rabbits were evaluated for determination of intraocular measurements using an ophthalmic ultrasound unit able to operate in both A and B-modes. The distances from the cornea to the anterior capsule of the lens (D1), from the anterior capsule of the lens to the posterior capsule of the lens (D2), from the posterior capsule of the lens to the retina (D3) and the complete length of the eye, which corresponds to the distance from the cornea to the retina (D4) were taken. The mean values obtained were 2.70 mm (± 0.22 mm) for D1, 7.32 mm (± 0.40 mm) for D2, 7.10 mm (± 0.45 mm) for D3 and 17.12 mm (± 0.41 mm) for D4. Statistical analyses using the Student's t-test showed that there were no differences between the eyes. The study was feasible without the need of pharmacological restraint and yielded normal mean values for ocular sonographic biometry in rabbits. © 2010 American College of Veterinary Ophthalmologists.

  11. Optical coherence tomography of dental structures

    NASA Astrophysics Data System (ADS)

    Baumgartner, Angela; Hitzenberger, Christoph K.; Dichtl, Sabine; Sattmann, Harald; Moritz, Andreas; Sperr, Wolfgang; Fercher, Adolf F.

    1998-04-01

    In the past ten years Partial Coherence Interferometry (PCI) and Optical Coherence Tomography (OCT) have been successfully developed for high precision biometry and tomography of biological tissues. OCT employs the partial coherence properties of a superluminescent diode and the Doppler principle yielding resolution and precision figures of the order of a few microns. Presently, the main application fields of this technique are biometry and imaging of ocular structures in vivo, as well as its clinical use in dermatology and endoscopic applications. This well established length measuring and imaging technique has now been applied to dentistry. First in vitro OCT images of the cemento (dentine) enamel junction of extracted sound and decayed human teeth have been recorded. These images distinguish dentine and enamel structures that are important for assessing enamel thickness and diagnosing caries. Individual optical A-Scans show that the penetration depth into enamel is considerably larger than into dentine. First polarization sensitive OCT recordings show localized changes of the polarization state of the light backscattered by dental material. Two-dimensional maps of the magnitude of the interference intensity and of the total phase difference between two orthogonal polarization states as a function of depth can reveal important structural information.

  12. Simultaneous refraction measurement and OCT axial biometry of the eye during accommodation (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    De Freitas, Carolina; Hernandez, Victor M.; Ruggeri, Marco; Durkee, Heather A.; Williams, Siobhan; Gregori, Giovanni; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie

    2016-03-01

    The purpose of this project is to design and evaluate a system that will enable objective assessment of the optical accommodative response in real-time while acquiring axial biometric information. The system combines three sub-systems which were integrated and mounted on a joystick x-y-z adjustable modified slit-lamp base to facilitate alignment and data acquisition: (1) a Shack-Hartmann wavefront sensor for dynamic refraction measurement, provided software calculates sphere, cylinder and axis values, (2) an extended-depth Optical Coherence Tomography (OCT) system using an optical switch records high-resolution cross-sectional images across the length of the eye, from which, dynamic axial biometry (corneal thickness, anterior chamber depth, crystalline lens thickness and vitreous depth) can be extracted, and (3) a modified dual-channel accommodation stimulus unit based on the Badal optometer for providing a step change in accommodative stimulus. The prototypal system is capable of taking simultaneous measurements of both the optical and the mechanical response of lens accommodation. These measurements can provide insight into correlating changes in lens shape with changes in lens power and ocular refraction and ultimately provide a more comprehensive understanding of accommodation, presbyopia and an objective assessment of presbyopia correction techniques.

  13. Accuracy of a new partial coherence interferometry analyser for biometric measurements.

    PubMed

    Holzer, M P; Mamusa, M; Auffarth, G U

    2009-06-01

    Precise biometry is an essential preoperative measurement for refractive surgery as well as cataract surgery. A new device based on partial coherence interferometry technology was tested and evaluated for accuracy of measurements. In a prospective study 200 eyes of 100 healthy phakic volunteers were examined with a functional prototype of the new ALLEGRO BioGraph (Wavelight AG)/LENSTAR LS 900 (Haag Streit AG) biometer and with the IOLMaster V.5 (Carl Zeiss Meditec AG). As recommended by the manufacturers, repeated measurements were performed with both devices and the results compared using Spearman correlation calculations (WinSTAT). Spearman correlation showed high correlations for axial length and keratometry measurements between the two devices tested. Anterior chamber depth, however, had a lower correlation between the two biometry devices. In addition, the mean values of the anterior chamber depth differed (IOLMaster 3.48 (SD 0.42) mm versus BioGraph/LENSTAR 3.64 (SD 0.26) mm); however, this difference was not statistically different (p>0.05, t test). The new biometer provided results that correlated very well with those of the IOLMaster. The ALLEGRO BioGraph/LENSTAR LS 900 is a precise device containing additional features that will be helpful tools for any cataract or refractive surgeon.

  14. Differences in the Biometry of the Levator Hiatus at Rest, During Contraction, and During Valsalva Maneuver Between Women With and Without Provoked Vestibulodynia Assessed by Transperineal Ultrasound Imaging.

    PubMed

    Thibault-Gagnon, Stéphanie; McLean, Linda; Goldfinger, Corrie; Pukall, Caroline; Chamberlain, Susan

    2016-02-01

    Pelvic floor muscle (PFM) involvement is suspected in the pathophysiology of provoked vestibulodynia (PVD); however, the underlying mechanisms are unclear. PFM morphology can be inferred from the biometry of the levator hiatus determined through dynamic ultrasound imaging. The aim of this study was to determine the nature of PFM involvement in women with PVD via an evaluation of the biometry of the levator hiatus at rest, upon maximal voluntary contraction (MVC) of the PFMs, and upon maximal Valsalva maneuver (MVM). Thirty-eight women with PVD and 39 asymptomatic controls were imaged using 3D transperineal ultrasound. Levator hiatal dimensions (area; left-right [LR] and anteroposterior [AP] diameters) were measured at rest, on MVC, and on MVM. Differences in hiatal dimensions and in relative changes in dimensions from rest to MVC and from rest to MVM were compared between groups using separate 1-way analyses of variance for each measure and task. Analysis of covariance models were used to investigate the impact of levator hiatal dimensions at rest on the relative changes in the levator hiatal dimensions during MVC and MVM. Levator hiatal area, LR, and AP diameters, at rest, on MVC, and on MVM were the main outcome measures. Relative changes in hiatal dimensions were assessed as the percent change in hiatal area, LR diameter, and AP diameter. In comparison with controls, women with PVD had smaller hiatal areas at rest, on MVC, and on MVM, concurrent with smaller LR diameters on MVM. Women with PVD had a significantly smaller change in hiatal area on MVM than controls, but no differences were evident on MVC. In both groups, smaller levator hiatal dimensions at rest were associated with smaller relative decreases in dimensions on MVC and larger relative increases in dimensions on MVM. In comparison to controls, women with PVD appear to have narrower levator hiatus' and less capacity to distend their hiatus on Valsalva. The state of the PFMs at rest appears to significantly influence biometric changes in the PFMs during contraction and Valsalva. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  15. Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

    PubMed

    Çağlar, Çağatay; Kocamış, Sücattin İlker; Demir, Emre; Durmuş, Mustafa

    2017-06-01

    To investigate the accuracy of the measurements of Nidek AL-Scan by comparing with Sirius (CSO, Florence, Italy), a corneal tomography which also employs the Scheimpflug principle, and a commonly used device, ultrasound biometry (UB) (Aviso A/B, Quantel Medical, MT, USA). Right eyes of 85 healthy volunteers (58 women 27 men) with a mean age of 39.24 ± 14.37 years (range 15-68) were enrolled into this comparative prospective study. Average K 2.4, average K 3.3, CCT (central corneal thickness), WTW (white to white distance), ACD (anterior chamber depth) and AL (axial length) were obtained from the AL-Scan and compared with average SimK, CCT, WTW (horizontal anterior chamber diameter) and ACD obtained from Sirius and also compared with ACD and AL obtained from UB. The statistically significant difference was found between all of the measurements (p < 0.001) except the average keratometry values (K2.4, K3.3, SimK) (p = 0.083). There was a perfect correlation between keratometry, CCT and AL measurements of the devices (ICC = 0.977, 0.954, 0.923, respectively) and there was a strong correlation between the WTW measurements of AL-Scan and Sirius (ICC = 0.865). While ACD parameter of AL-Scan and UB showed a perfect correlation (ICC = 0.977), there was a moderate correlation between AL-Scan and Sirius and also between UB and Sirius (ICC = 0.608 and 0.664, respectively). There was a high correlation between the all measurements, besides ACD, of AL-Scan and Sirius and they can be used interchangeably for average keratometry and WTW confidently. However, ACD and CCT have a broader 95 % LoA (-0.039 to 0.744 and -24.985 to 3.691, respectively). In addition, AL-Scan and UB were in good agreement regarding ACD, while differences in AL measurements of UB and AL-Scan were clinically important (95 % LoA = -0.091 to 0.703). Furthermore, UB and Sirius have a moderate agreement regarding ACD (95 % LoA = -0.047 to 0.680).

  16. An Analysis of Federal Airport and Air Carrier Employee Access Control, Screening. and Training Regulations

    DTIC Science & Technology

    1998-03-01

    traveling public, air carriers, and persons employed by or conducting business at public airports. 14. SUBJECT TERMS Airport Security , Federal...26 4. Sterile Area 28 5. Exclusive Area 28 E. SECURITY ALERT LEVELS 29 F. AIRPORT SECURITY TOOLS 30 1. Electronic Detection System 31 a... Security Coordinator ASP Airport Security Program BIS Biometrie Identification System CCTV Closed Circuit Television CJIS Criminal Justice Information

  17. VIIP Bedrest Analog Roadmap

    NASA Technical Reports Server (NTRS)

    Villarreal, Jennifer D.

    2014-01-01

    The objective is to define successive bed rest campaigns leading to a potential VIIP (Vision Impairment and Intracranial Pressure) countermeasure. To determine if the analog is successful, changes need to occur in the following outcome measures (dependent variables): Intracranial pressure; Retinal nerve fiber layer; Choroidal engorgement; Globe flattening; Axial biometry; Optic nerve sheath diameter distention; Cycloplegic refraction; Visual acuity. Study parameters (independent variables) to include: CO2; Sodium; Exercise (resistive & aerobic); Strict tilt angle.

  18. LBA-ECO TG-07 Ground-based Biometry Data at km 83 Site, TapajosNational Forest: 1997

    Treesearch

    M.M. Keller; M.W. Palace

    2009-01-01

    A field inventory of trees was conducted in March of 1997 in a logging concession at the Tapajos National Forest, south of Santarem, Para, Brazil. The inventory was conducted by the foresters and technicians of the Tropical Forest Foundation (FFT) and included all trees with diameter at breast height greater than or equal to 35 cm. Four blocks of approximately 100 ha...

  19. Relationship between lenticular power and refractive error in children with hyperopia.

    PubMed

    Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro

    2013-01-01

    To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia.

  20. Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography.

    PubMed

    Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won

    2017-01-01

    To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.

  1. Secure Fingerprint Identification of High Accuracy

    DTIC Science & Technology

    2014-01-01

    secure ) solution of complexity O(n3) based on Gaussian elimination. When it is applied to biometrics X and Y with mX and mY minutiae, respectively...collections of biometric data in use today include, for example, fingerprint, face, and iris images collected by the US Department of Homeland Security ...work we focus on fingerprint data due to popularity and good accuracy of this type of biometry. We formulate the problem of private, or secure , finger

  2. A new A-scan ultrasonoscope.

    PubMed

    Bronson, N R

    1984-05-01

    A new A-mode biometry system for determining axial length measurements of the eye has been developed that incorporates a soft-membrane transducer. The soft transducer decreases the risk of indenting the cornea with the probe resulting in inaccurate measurements. A microprocessor evaluates echo patterns and determines whether or not axial alignment has been obtained, eliminating possible user error. The new A-scan requires minimal user skill and can be used successfully by both physician and technician.

  3. Factors controlling CO2 exchange on timescales from hourly to decadal at Harvard Forest

    Treesearch

    Shawn Urbanski; C. Barford; S. Wofsy; C. Kucharik; E. Pyle; J. Budney; K. McKain; D. Fitzjarrald; M. Czikowsky; J. W. Munger

    2007-01-01

    We analyzed 13 years (1992-2004) of CO2 flux data, biometry, and meteorology from a mixed deciduous forest in central Massachusetts. Annual net uptake of CO2 ranged from 1.0 to 4.7 Mg-C ha-1yr-1, with an average of 2.5 Mg-C ha-1yr-1. Uptake rates increased systematically, nearly doubling over the period despite forest age of 75–110 years; there were...

  4. Relationship between lenticular power and refractive error in children with hyperopia

    PubMed Central

    Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro

    2013-01-01

    Objectives To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. Methods There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. Results There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Conclusion Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia. PMID:23576859

  5. Refraction and Ocular Biometry of Preschool Children in Shanghai, China

    PubMed Central

    He, Xiangui; You, Xiaofang; Wang, Bingjie; Tan, Hui; Zhu, Jianfeng

    2018-01-01

    Purpose To investigate the refraction and ocular biometry characteristics and to examine the prevalence of refractive errors in preschool children aged 3 to 6 years in Shanghai, China. Methods A school-based cross-sectional study was conducted in Jiading and Xuhui District, Shanghai, in 2013. We randomly selected 7 kindergartens in Jiading District and 10 kindergartens in Xuhui District, with a probability proportionate to size. The children underwent comprehensive eye examinations, including cycloplegic refraction and biometric measurements. Myopia, hyperopia, astigmatism were defined as spherical equivalent (SE) ≤ −0.50 D, SE ≥ +2.00 D, and cylindrical diopters ≤ −1.00 D. Results The mean SE for 3- to 6-year-old children was +1.20 D (standard deviation [SD] 1.05), and the mean axial length (AL) was 22.29 mm (SD 0.73). The overall prevalence of myopia and astigmatism was 3.7% and 18.3%, respectively. No difference in prevalence of astigmatism was found across age groups. There was a statistically significant association between lower cylindrical diopters and higher spherical diopters (Spearman's correlation: −0.21, P < 0.001). Conclusion Chinese children aged 3 to 6 years in the Shanghai area were mostly mildly hyperopic, with a low prevalence of myopia. Refractive astigmatism for children may be relatively stable throughout the preschool stage. Astigmatism was significantly associated with refractive error. PMID:29692930

  6. Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.

    PubMed

    Helaly, Hany A; El-Hifnawy, Mohammad A M; Shaheen, Mohamed Shafik; Abou El-Kheir, Amr F

    2016-01-01

    To evaluate the accuracy of corneal power measurements for intraocular lens (IOL) power calculation after myopic laser in situ keratomileusis (LASIK). The study evaluated 45 eyes with a history of myopic LASIK. Corneal power was measured using manual keratometry, automated keratometry, optical biometry, and Scheimflug tomography. Different hypothetical IOL power calculation formulas were performed for each case. The steepest mean K value was measured with manual keratometry (37.48 ± 2.86 D) followed by automated keratometry (37.31 ± 2.83 D) then optical biometry (37.06 ± 2.98 D) followed by Scheimflug tomography (36.55 ± 3.08). None of the K values generated by Scheimflug tomography were steeper than the measurements from the other 3 instruments. Using equivalent K reading (EKR) 4 mm with the Double-K SRK/T formula, the refractive outcome generated 97.8% of cases within ± 2 D, 80.0% of cases within ± 1 D, and 42.2% of cases within ± 0.5 D. The best combination of formulas was "Shammas-PL + Double-K SRK/T formula using EKR 4 mm." Scheimflug tomography imaging using the Holladay EKR 4 mm improved the accuracy of IOL power calculation in post-LASIK eyes. The best option is a combination of formulas. We recommended the use the combined "Shammas-PL ± Double-K SRK/T formula using EKR 4 mm"h for optical outcomes.

  7. Screening for fetal growth restriction with universal third trimester ultrasonography in nulliparous women in the Pregnancy Outcome Prediction (POP) study: a prospective cohort study.

    PubMed

    Sovio, Ulla; White, Ian R; Dacey, Alison; Pasupathy, Dharmintra; Smith, Gordon C S

    2015-11-21

    Fetal growth restriction is a major determinant of adverse perinatal outcome. Screening procedures for fetal growth restriction need to identify small babies and then differentiate between those that are healthy and those that are pathologically small. We sought to determine the diagnostic effectiveness of universal ultrasonic fetal biometry in the third trimester as a screening test for small-for-gestational-age (SGA) infants, and whether the risk of morbidity associated with being small differed in the presence or absence of ultrasonic markers of fetal growth restriction. The Pregnancy Outcome Prediction (POP) study was a prospective cohort study of nulliparous women with a viable singleton pregnancy at the time of the dating ultrasound scan. Women participating had clinically indicated ultrasonography in the third trimester as per routine clinical care and these results were reported as usual (selective ultrasonography). Additionally, all participants had research ultrasonography, including fetal biometry at 28 and 36 weeks' gestational age. These results were not made available to participants or treating clinicians (universal ultrasonography). We regarded SGA as a birthweight of less than the 10th percentile for gestational age and screen positive for SGA an ultrasonographic estimated fetal weight of less than the 10th percentile for gestational age. Markers of fetal growth restriction included biometric ratios, utero-placental Doppler, and fetal growth velocity. We assessed outcomes for consenting participants who attended research scans and had a livebirth at the Rosie Hospital (Cambridge, UK) after the 28 weeks' research scan. Between Jan 14, 2008, and July 31, 2012, 4512 women provided written informed consent of whom 3977 (88%) were eligible for analysis. Sensitivity for detection of SGA infants was 20% (95% CI 15-24; 69 of 352 fetuses) for selective ultrasonography and 57% (51-62; 199 of 352 fetuses) for universal ultrasonography (relative sensitivity 2·9, 95% CI 2·4-3·5, p<0·0001). Of the 3977 fetuses, 562 (14·1%) were identified by universal ultrasonography with an estimated fetal weight of less than the 10th percentile and were at an increased risk of neonatal morbidity (relative risk [RR] 1·60, 95% CI 1·22-2·09, p=0·0012). However, estimated fetal weight of less than the 10th percentile was only associated with the risk of neonatal morbidity (pinteraction=0·005) if the fetal abdominal circumference growth velocity was in the lowest decile (RR 3·9, 95% CI 1·9-8·1, p=0·0001). 172 (4%) of 3977 pregnancies had both an estimated fetal weight of less than the 10th percentile and abdominal circumference growth velocity in the lowest decile, and had a relative risk of delivering an SGA infant with neonatal morbidity of 17·6 (9·2-34·0, p<0·0001). Screening of nulliparous women with universal third trimester fetal biometry roughly tripled detection of SGA infants. Combined analysis of fetal biometry and fetal growth velocity identified a subset of SGA fetuses that were at increased risk of neonatal morbidity. National Institute for Health Research, Medical Research Council, Sands, and GE Healthcare. Copyright © 2015 Sovio et al. Open Access article distributed under the terms of CC BY. Published by Elsevier Ltd.. All rights reserved.

  8. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study.

    PubMed

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40-36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%-49.74%), 22.82% (95% CI: 21.77%-23.88%), and 4.57% (95% CI: 4.05-5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years.

  9. Comparison of Accuracy in Intraocular Lens Power Calculation by Measuring Axial Length with Immersion Ultrasound Biometry and Partial Coherence Interferometry.

    PubMed

    Ruangsetakit, Varee

    2015-11-01

    To re-examine relative accuracy of intraocular lens (IOL) power calculation of immersion ultrasound biometry (IUB) and partial coherence interferometry (PCI) based on a new approach that limits its interest on the cases in which the IUB's IOL and PCI's IOL assignments disagree. Prospective observational study of 108 eyes that underwent cataract surgeries at Taksin Hospital. Two halves ofthe randomly chosen sample eyes were implanted with the IUB- and PCI-assigned lens. Postoperative refractive errors were measured in the fifth week. More accurate calculation was based on significantly smaller mean absolute errors (MAEs) and root mean squared errors (RMSEs) away from emmetropia. The distributions of the errors were examined to ensure that the higher accuracy was significant clinically as well. The (MAEs, RMSEs) were smaller for PCI of (0.5106 diopter (D), 0.6037D) than for IUB of (0.7000D, 0.8062D). The higher accuracy was principally contributedfrom negative errors, i.e., myopia. The MAEs and RMSEs for (IUB, PCI)'s negative errors were (0.7955D, 0.5185D) and (0.8562D, 0.5853D). Their differences were significant. The 72.34% of PCI errors fell within a clinically accepted range of ± 0.50D, whereas 50% of IUB errors did. PCI's higher accuracy was significant statistically and clinically, meaning that lens implantation based on PCI's assignments could improve postoperative outcomes over those based on IUB's assignments.

  10. The relationship of birth weight, gestational age, and postmenstrual age with ocular biometry parameters in premature infants.

    PubMed

    Ozdemir, Ozdemir; Tunay, Zuhal Ozen; Acar, Damla Erginturk; Erol, Muhammet Kazım; Sener, Ender; Acar, Ugur

    2015-01-01

    To analyze ocular biometry parameters and evaluate their relationship with gestational age, birth weight, and postmenstrual age in prematurely born infants. The right eyes of 361 premature infants born before the 36th gestational week were evaluated. Birth weight, gestational week, and gender were recorded. An A-scan Biometer was used for obtaining axial measurements, including anterior chamber depth, lens thickness, vitreous length, and total axial length. Gestational age and birth weight values ranged from 23 to 36 weeks and from 560 to 2,670 g, respectively. The mean gestational age and birth weight were 30.8 ± 2.8 weeks and 1,497.9 ± 483.6 g, respectively. During the first examination (4-5 weeks of postnatal age), birth weight and gestational age of the infants correlated significantly and positively with lens thickness, vitreous length, and axial length (r>0.5, p<0.001), but not with anterior chamber depth (r<0.5). Increased vitreous and axial lengths correlated significantly with increasing postmenstrual age of the infants (r=0.669, p<0.001; r=0.845, p<0.001, respectively). Lens thickness, vitreous length, and axial length, but not anterior chamber depth, were significantly correlated with birth weight and gestational age. All four parameters increased with increasing postmenstrual age, with higher correlations for vitreous and axial lengths than for anterior chamber depth and lens thickness. It was concluded that axial elongation resulted primarily from increasing posterior chamber length.

  11. The relationship between refractive and biometric changes during Edinger–Westphal stimulated accommodation in rhesus monkeys

    PubMed Central

    Vilupuru, Abhiram S.; Glasser, Adrian

    2010-01-01

    Experiments were undertaken to understand the relationship between dynamic accommodative refractive and biometric (lens thickness (LT), anterior chamber depth (ACD) and anterior segment length (ASL=ACD+LT)) changes during Edinger–Westphal stimulated accommodation in rhesus monkeys. Experiments were conducted on three rhesus monkeys (aged 11·5, 4·75 and 4·75 years) which had undergone prior, bilateral, complete iridectomies and implantation of a stimulating electrode in the Edinger–Westphal (EW) nucleus. Accommodative refractive responses were first measured dynamically with video-based infrared photorefraction and then ocular biometric responses were measured dynamically with continuous ultrasound biometry (CUB) during EW stimulation. The same stimulus amplitudes were used for the refractive and biometric measurements to allow them to be compared. Main sequence relationships (ratio of peak velocity to amplitude) were calculated. Dynamic accommodative refractive changes are linearly correlated with the biometric changes and accommodative biometric changes in ACD, ASL and LT show systematic linear correlations with increasing accommodative amplitudes. The relationships are relatively similar for the eyes of the different monkeys. Dynamic analysis showed that main sequence relationships for both biometry and refraction are linear. Although accommodative refractive changes in the eye occur primarily due to changes in lens surface curvature, the refractive changes are well correlated with A-scan measured accommodative biometric changes. Accommodative changes in ACD, LT and ASL are all well correlated over the full extent of the accommodative response. PMID:15721617

  12. An observational study on changes in biometry and generation time of Odontophora villoti (Nematoda, Axonolaimidae) related to petroleum pollution in Bizerte bay, Tunisia.

    PubMed

    Boufahja, Fehmi; Hedfi, Amor; Essid, Naceur; Aïssa, Patricia; Mahmoudi, Ezzeddine; Beyrem, Hamouda

    2012-03-01

    We conducted a yearly polluted-reference sampling to assess the effects of petroleum pollution on life cycle characteristics of the meiobenthic nematode Odontophora villoti. Samples were taken every 15 days between 26 November 2004 and 25 November 2005 from two beaches of Bizerte bay (Tunisia), Rimel and Tunisian Refining Industries Company (TRIC). The latter site is located in front of the "Tunisian Refining Industries Company" runoff. When compared to the reference site, the mean body dimensions of O. villoti from the impacted site were significantly lower. The small size of affected nematodes was represented both by the length and width as a function of the life stage. It was also established that changes in lengths of body parts during molts were different between the two study sites. The low availability of oxygen from April to August seems to prevent the formation of embryos of O. villoti. Thus, two annual reproductive cycles with different durations were observed in Rimel and TRIC. Under stress, juvenile phase and egg production were generally shorter. Globally, the impact of petroleum pollution on O. villoti was expressed by a short egg-to-egg development time. Our study assessed the usefulness of life cycle characteristics (biometry and life stage durations) of O. villoti in biomonitoring, and the results are generally consistent suggesting that this species may be considered as an efficient bioindicator.

  13. Screening for fetal growth restriction using fetal biometry combined with maternal biomarkers.

    PubMed

    Gaccioli, Francesca; Aye, Irving L M H; Sovio, Ulla; Charnock-Jones, D Stephen; Smith, Gordon C S

    2018-02-01

    Fetal growth restriction is a major determinant of perinatal morbidity and mortality. Screening for fetal growth restriction is a key element of prenatal care but it is recognized to be problematic. Screening using clinical risk assessment and targeting ultrasound to high-risk women is the standard of care in the United States and United Kingdom, but the approach is known to have low sensitivity. Systematic reviews of randomized controlled trials do not demonstrate any benefit from universal ultrasound screening for fetal growth restriction in the third trimester, but the evidence base is not strong. Implementation of universal ultrasound screening in low-risk women in France failed to reduce the risk of complications among small-for-gestational-age infants but did appear to cause iatrogenic harm to false positives. One strategy to making progress is to improve screening by developing more sensitive and specific tests with the key goal of differentiating between healthy small fetuses and those that are small through fetal growth restriction. As abnormal placentation is thought to be the major cause of fetal growth restriction, one approach is to combine fetal biometry with an indicator of placental dysfunction. In the past, these indicators were generally ultrasonic measurements, such as Doppler flow velocimetry of the uteroplacental circulation. However, another promising approach is to combine ultrasonic suspicion of small-for-gestational-age infant with a blood test indicating placental dysfunction. Thus far, much of the research on maternal serum biomarkers for fetal growth restriction has involved the secondary analysis of tests performed for other indications, such as fetal aneuploidies. An exemplar of this is pregnancy-associated plasma protein A. This blood test is performed primarily to assess the risk of Down syndrome, but women with low first-trimester levels are now serially scanned in later pregnancy due to associations with placental causes of stillbirth, including fetal growth restriction. The development of "omic" technologies presents a huge opportunity to identify novel biomarkers for fetal growth restriction. The hope is that when such markers are measured alongside ultrasonic fetal biometry, the combination would have strong predictive power for fetal growth restriction and its related complications. However, a series of important methodological considerations in assessing the diagnostic effectiveness of new tests will have to be addressed. The challenge thereafter will be to identify novel disease-modifying interventions, which are the essential partner to an effective screening test to achieve clinically effective population-based screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Biometry, biometrics, biostatistics, bioinformatics,..., bio-X.

    PubMed

    Molenberghs, Geert

    2005-03-01

    Recent scientific evolutions force us to rethink our profession's position on the scientific map, in relation to our neighboring professions, the ones with which we traditionally have strong collaborative links as well as the newly emerging fields, but also within our own, diverse professional group. We will show that great inspiration can be drawn from our own history, in fact from the early days of the Society. A recent inspiring example has been set by the late Rob Kempton, who died suddenly just months before he was to become President of the International Biometric Society.

  15. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study

    PubMed Central

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    Purpose To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Methods Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. Results We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40–36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%–49.74%), 22.82% (95% CI: 21.77%–23.88%), and 4.57% (95% CI: 4.05–5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Conclusion Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years. PMID:28114313

  16. Progressive myopia or hyperopia can be induced in chicks and reversed by manipulation of the chromaticity of ambient light.

    PubMed

    Foulds, Wallace S; Barathi, Veluchamy A; Luu, Chi D

    2013-12-09

    To determine whether progressive ametropia can be induced in chicks and reversed by manipulation of the chromaticity of ambient light. One-day-old chicks were raised in red light (90% red, 10% yellow-green) or in blue light (85% blue, 15% green) with a 12 hour on/off cycle for 14 to 42 days. Refraction was determined by streak retinoscopy, and by automated infrared photoretinoscopy and ocular biometry by A-scan ultrasonography. Red light induced progressive myopia (mean refraction ± SD at 28 days, -2.83 ± 0.25 diopters [D]). Progressive hyperopia was induced by blue light (mean refraction at 28 days, +4.55 ± 0.21 D). The difference in refraction between the groups was highly significant at P < 0.001. Induced myopia or hyperopia was axial as confirmed by ultrasound biometry. Myopia induced by 21 days of red light (-2.21 ± 0.21 D) was reversed to hyperopia (+2.50 ± 0.29 D) by subsequent 21 days of blue light. Hyperopia induced by 21 days of blue light (+4.21 ± 0.19 D) was reversed to myopia (-1.23 ± 0.12 D) by 21 days of red light. Rearing chicks in red light caused progressive myopia, while rearing in blue light caused progressive hyperopia. Light-induced myopia or hyperopia in chicks can be reversed to hyperopia or myopia, respectively, by an alteration in the chromaticity of ambient light. Manipulation of chromaticity may be applicable to the management of human childhood myopia.

  17. Ray-tracing analysis of intraocular lens power in situ.

    PubMed

    Olsen, Thomas; Funding, Mikkel

    2012-04-01

    To describe a method for back-solving the power of an intraocular lens (IOL) in situ based on laser biometry and ray-tracing analysis of the pseudophakic eye. University Eye Clinic, Aarhus Hospital, Aarhus, Denmark. Evaluation of diagnostic test or technology. This study comprised pseudophakic eyes with an IOL power ranging from -2.00 to +36.00 diopters (D). Preoperatively, the corneal radius was measured with conventional autokeratometry and the axial length (AL) with optical biometry. After surgery, the position of the IOL was recorded using laser interferometry. Based on the postoperative refraction and the biometric measurements, a ray-tracing analysis was performed back-solving for the power of the IOL in situ. The analysis was performed assuming pupil diameters from 0.0 to 8.0 mm with and without correction for the Stiles-Crawford effect. The study evaluated 767 pseudophakic eyes (583 patients). Assuming a 3.0 mm pupil, the mean prediction error between the labeled and the calculated IOL power (± 1 standard deviation [SD]) was -0.26 D ± 0.65 (SD) (range -2.4 to +1.8 D). The prediction error showed no bias with IOL power or with AL. The calculated IOL power depended on the assumed pupil size and the Stiles-Crawford effect. However, the latter had a modulatory effect on the prediction error for large pupil diameters (>5.0 mm) only. The optics of the pseudophakic eye can be accurately described using exact ray tracing and modern biometric techniques. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Ophthalmic Phenotypes and the Representativeness of Twin Data for the General Population

    PubMed Central

    Sanfilippo, Paul G.; Medland, Sarah E.; Hewitt, Alex W.; Kearns, Lisa S.; Ruddle, Jonathan B.; Sun, Cong; Hammond, Christopher J.; Young, Terri L.; Martin, Nicholas G.

    2011-01-01

    Purpose. To compare the distributional parameters for a series of ocular biometric traits between twins and their singleton siblings, to evaluate the generalizability of twin data, as used in heritability analyses to the general population. Methods. A series of birth, anthropometric, and 13 ocular biometric traits were selected for analysis: interpupillary distance (IPD), visual acuity (logMAR), spherical equivalent refractive error, corneal curvature, axial length, anterior chamber depth (ACD), central corneal thickness (CCT), intraocular pressure (IOP), optic disc, cup and rim areas, and measures of retinal vessel caliber; central retinal arteriolar equivalent (CRAE), and central retinal venular equivalent (CRVE). Structural equation modeling was used to test the assumption that the means and variances for each trait did not differ between twins and their siblings. Results. Significant differences in log-likelihood for birth weight and gestational age were observed between twins and siblings, with the latter being both heavier and closer to full-term at birth. Siblings were also found to have larger IPD and axial length, and better visual acuity compared with their twin counterparts. Refractive error, corneal curvature, ACD, CCT, optic disc parameters, and retinal vascular calibers did not differ significantly between the two groups. Conclusions. Twins are representative of the general population for some but not all measures of ocular biometry. Consequently, care should be taken when extrapolating twin data for these traits in heritability and other genetic studies. Birth weight differences between twins and siblings do not appear to account for the differences in ocular biometry observed in this study. PMID:21498610

  19. Can the accuracy of multifocal intraocular lens power calculation be improved to make patients spectacle free?

    PubMed

    Ramji, Hasnain; Moore, Johnny; Moore, C B Tara; Shah, Sunil

    2016-04-01

    To optimise intraocular lens (IOL) power calculation techniques for a segmental multifocal IOL, LENTIS™ MPlus(®) (Oculentis GmbH, Berlin, Germany) and assess outcomes. A retrospective consecutive non-randomised case series of patients receiving the MPlus(®) IOL following cataract surgery or clear lens extraction was performed at a privately owned ophthalmic hospital, Midland Eye, Solihull, UK. Analysis was undertaken of 116 eyes, with uncomplicated lens replacement surgery using the LENTIS™ MPlus(®) lenses. Pre-operative biometry data were stratified into short (<22.00 mm) and long axial lengths (ALs) (≥22.00 mm). IOL power predictions were calculated with SRK/T, Holladay I, Hoffer Q, Holladay II and Haigis formulae and compared to the final manifest refraction. These were compared with the OKULIX ray tracing method and the stratification technique suggested by the Royal College of Ophthalmologists (RCOphth). Using SRK/T for long eyes and Hoffer Q for short eyes, 64% achieved postoperative subjective refractions of ≤±0.25 D, 83%≤±0.50 D and 93%≤±0.75 D, with a maximum predictive error of 1.25D. No specific calculation method performed best across all ALs; however for ALs under 22 mm Hoffer Q and Holliday I methods performed best. Excellent but equivalent overall refractive results were found between all biometry methods used in this multifocal IOL study. For eyes with ALs under 22 mm Hoffer Q and Holliday I performed best. Current techniques mean that patients are still likely to need top up glasses for certain situations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography.

    PubMed

    Sampson, Danuta M; Gong, Peijun; An, Di; Menghini, Moreno; Hansen, Alex; Mackey, David A; Sampson, David D; Chen, Fred K

    2017-06-01

    To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA). Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae. Relative changes between corrected and uncorrected SRVD and FAZA were calculated. Forty subjects were enrolled and the median (range) age of the participants was 30 (18-74) years. The mean (range) spherical equivalent refractive error was -1.65 (-8.00 to +4.88) diopters and mean (range) axial length was 24.42 mm (21.27-28.85). Images from 13 eyes were excluded due to poor image quality leaving 67 for analysis. Relative changes in foveal and parafoveal SRVD and FAZA after correction ranged from -20% to +10%, -3% to +2%, and -20% to +51%, respectively. Image size correction in measurements of foveal SRVD and FAZA was greater than 5% in 51% and 74% of eyes, respectively. In contrast, 100% of eyes had less than 5% correction in measurements of parafoveal SRVD. Ocular biometry should be performed with OCTA to correct image magnification error induced by axial length variation. We advise caution when interpreting interocular and interindividual comparisons of SRVD and FAZA derived from OCTA without image size correction.

  1. Ethnic variations in myopia and ocular biometry among adults in a rural community in China: the Yunnan minority eye studies.

    PubMed

    Pan, Chen-Wei; Chen, Qin; Sheng, Xun; Li, Jun; Niu, Zhiqiang; Zhou, Hua; Wei, Tao; Yuan, Yuansheng; Zhong, Hua

    2015-05-01

    To determine the prevalence of myopia and ocular biometry in population-based samples of ethnic Yi and Han people living in an inland rural community in China. A random cluster sampling strategy was used to select ethnic Han and Yi adults aged 50 years or older living in Yunnan. Refractive error was determined by subjective refraction and ocular biometric parameters, including axial length (AL), anterior chamber depth (ACD), vitreous chamber depth (VCD), and lens thickness (LT), which were measured using an Echoscan. Adults of Yi ethnicity had lower prevalence of myopia (10.3% vs. 8.1%; P = 0.02) and high myopia (2.3% vs. 1.6%; P = 0.10) than their counterparts of Han ethnicity. The prevalence of myopia increased with age (P for trend < 0.05), whereas the mean AL did not differ significantly among age groups in both ethnic groups (both P for trend > 0.05). In multivariate analysis, time spent outdoors was associated with myopia (P = 0.003) and AL (P < 0.001) but not high myopia (P = 0.33). No interaction effect was detected between ethnicity and other risk factors on myopia (all P > 0.05). Adjustment for lens nuclear opacity score reduced the excess prevalence of myopia in Han ethnicity by 37.5%. There was little evidence showing that ethnic disparities existed in the prevalence and risk factors between the major and minor ethnic groups living in the same communities in rural China. The "cohort effect" on myopia observed in many other populations was not seen in this study.

  2. OPHTHALMIC REFERENCE VALUES AND LESIONS IN TWO CAPTIVE POPULATIONS OF NORTHERN OWLS: GREAT GREY OWLS (STRIX NEBULOSA) AND SNOWY OWLS (BUBO SCANDIACUS).

    PubMed

    Wills, Sarah; Pinard, Chantale; Nykamp, Stephanie; Beaufrère, Hugues

    2016-03-01

    This study established ophthalmic reference values and characterized ocular lesions in two captive populations of boreal owls, including 46 eyes of 23 great grey owls (Strix nebulosa) and 38 eyes from 19 snowy owls (Bubo scandiacus). A complete ophthalmologic exam was conducted, including neuro-ophthalmic reflexes, Schirmer tear test I (STT-I), intraocular pressure (IOP) using rebound tonometry, fluorescein staining, horizontal corneal measurements using Jameson calipers, direct and indirect ophthalmoscopy, and ocular ultrasound biometry. Eyes with an STT of <5 mm/min, outliers, and eyes with severe diseases were excluded from reference value analysis. No statistically significant differences were found between right or left eyes in either species or among individuals in different age groups and sexes. Mean intraocular pressures and Schirmer tear tests were also not statistically significantly different between great grey owls and snowy owls (IOP: 9.6 ± 2.6 mm Hg and 9.1 ± 1.9 mm Hg, respectively, and STT-I: 9.8 ± 2.8 mm/min and 9.8 ± 2.4 mm/min, respectively). However, snowy owls overall had a significantly larger eye than did great grey owls, reflected in corneal diameters (23.4 ± 1 vs. 20.0 ± 0.8 mm, respectively) and sonographic biometry. In both species, the most common ocular lesions included keratitis, cataracts, chorioretinal lesions, and abnormal pecten. Establishment of reference ocular parameters will help wildlife veterinarians and rehabilitators determine an appropriate treatment plan and will aid in correctly identifying the presence of ocular disease.

  3. Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry.

    PubMed

    Huang, Jinhai; McAlinden, Colm; Huang, Yingying; Wen, Daizong; Savini, Giacomo; Tu, Ruixue; Wang, Qinmei

    2017-02-24

    A meta-analysis to compare ocular biometry measured by optical low-coherence reflectometry (Lenstar LS900; Haag Streit) and partial coherence interferometry (the IOLMaster optical biometer; Carl Zeiss Meditec). A systematic literature search was conducted for articles published up to August 6th 2015 in the Cochrane Library, PubMed, Medline, Embase, China Knowledge Resource Integrated Database and Wanfang Data. A total of 18 studies involving 1921 eyes were included. There were no statistically significant differences in axial length (mean difference [MD] 0 mm; 95% confidence interval (CI) -0.08 to 0.08 mm; p = 0.92), anterior chamber depth (MD 0.02 mm; 95% CI -0.07 to 0.10 mm; p = 0.67), flat keratometry (MD -0.05 D; 95% CI -0.16 to 0.06 D; p = 0.39), steep keratometry (MD -0.09 D; 95% CI -0.20 to 0.03 D; p = 0.13), and mean keratometry (MD -0.15 D; 95% CI -0.30 to 0.00 D; p = 0.05). The white to white distance showed a statistically significant difference (MD -0.14 mm; 95% CI -0.25 to -0.02 mm; p = 0.02). In conclusion, there was no difference in the comparison of AL, ACD and keratometry readings between the Lenstar and IOLMaster. However the WTW distance indicated a statistically significant difference between the two devices. Apart from the WTW distance, measurements for AL, ACD and keratometry readings may be used interchangeability with both devices.

  4. Correlation Between Transperineal 3-Dimensional Ultrasound Measurements of Levator Hiatus and Female Sexual Function.

    PubMed

    Aydin, Serdar; Bakar, Rabia Zehra; Arioğlu Aydin, Çağri; Ateş, Seda

    The aim of this study is to investigate the association of sexual functions with levator hiatus biometry measurements and levator ani muscle defect. In 62 heterosexual, sexually active premenopausal women without pelvic floor disorders or urinary incontinence, 3-dimensional transperineal ultrasound imaging was used. Two 3-dimensional volumes were recorded, one at rest and one on Valsalva maneuver. Levator biometry measurements and levator defect were evaluated in an axial plane. Sexual function was assessed by a validated questionnaire, Female Sexual Function Index (FSFI). The primary outcome measure was correlation of sexual functions with the levator hiatus area, transverse and anteroposterior diameters, levator ani muscle thickness, vaginal length, and changes in measurements with Valsalva and levator defect. Forty-two women (67.7%) had low total FSFI scores (<26.55). Levator defect rates were similar in female sexual dysfunction (7/42, 16.7%) and women without female sexual dysfunction (5/20, 25%). The FSFI was negatively and weakly correlated with Δhiatal anteroposterior diameter (r = -0.33, P < 0.009) in the study population. There was a weak and inverse correlation between Δhiatal anteroposterior diameter and arousal (r = -0.35, P < 0.002), desire (r = -0.38, P < 0.001), and orgasm (r = -0.33, P < 0.007). Pain and lubrication did not correlate with any measurement. Hiatal area and diameters at rest are not related to sexual functions. Changes in anteroposterior diameter of the levator hiatus during Valsalva, which may be a sign of pelvic floor laxity or levator muscle weakness, are weakly associated with sexual functions, particularly desire, arousal, and orgasm domains.

  5. Pelvic floor muscle biometry and pelvic organ mobility in East Asian and Caucasian nulliparae.

    PubMed

    Cheung, R Y K; Shek, K L; Chan, S S C; Chung, T K H; Dietz, H P

    2015-05-01

    To compare the differences in levator ani muscle biometry and hiatal dimensions between pregnant nulliparous Caucasian and East Asian women. Offline analysis of three/four-dimensional ultrasound volume data obtained from two groups of pregnant nulliparous women, Caucasian and East Asian, was performed. Volume acquisition was performed in the late third trimester using the same method in both groups, in the context of two prospective observational studies with identical entry criteria. Pelvic organ descent and levator hiatal dimensions were assessed using the volumes acquired on Valsalva maneuver, and pubovisceral muscle thickness was measured from the volumes obtained on pelvic floor muscle contraction (PFMC). Datasets of 200 East Asian and 168 Caucasian women were analyzed. Compared with Caucasian women, East Asian women had a significantly lower body mass index. All indices of pelvic organ descent were significantly higher in the Caucasian group than in the East Asian group. The difference, expressed as a percentage, in levator hiatal area on both Valsalva maneuver and PFMC was markedly greater in Caucasian (32% vs. 19%; P < 0.001) than in East Asian (24% vs. 20%; P = 0.01) women. After controlling for potential confounders using multivariate regression analysis, racial origin remained the only significant factor associated with differences in pelvic organ descent and hiatal dimensions. The thickness and area of pubovisceral muscle were significantly higher in the East Asian group. Pregnant women of East Asian racial origin have a thicker pubovisceral muscle, smaller hiatus and less mobility of pelvic organs than do pregnant Caucasian women. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  6. Automated feature extraction for retinal vascular biometry in zebrafish using OCT angiography

    NASA Astrophysics Data System (ADS)

    Bozic, Ivan; Rao, Gopikrishna M.; Desai, Vineet; Tao, Yuankai K.

    2017-02-01

    Zebrafish have been identified as an ideal model for angiogenesis because of anatomical and functional similarities with other vertebrates. The scale and complexity of zebrafish assays are limited by the need to manually treat and serially screen animals, and recent technological advances have focused on automation and improving throughput. Here, we use optical coherence tomography (OCT) and OCT angiography (OCT-A) to perform noninvasive, in vivo imaging of retinal vasculature in zebrafish. OCT-A summed voxel projections were low pass filtered and skeletonized to create an en face vascular map prior to connectivity analysis. Vascular segmentation was referenced to the optic nerve head (ONH), which was identified by automatically segmenting the retinal pigment epithelium boundary on the OCT structural volume. The first vessel branch generation was identified as skeleton segments with branch points closest to the ONH, and subsequent generations were found iteratively by expanding the search space outwards from the ONH. Biometric parameters, including length, curvature, and branch angle of each vessel segment were calculated and grouped by branch generation. Despite manual handling and alignment of each animal over multiple time points, we observe distinct qualitative patterns that enable unique identification of each eye from individual animals. We believe this OCT-based retinal biometry method can be applied for automated animal identification and handling in high-throughput organism-level pharmacological assays and genetic screens. In addition, these extracted features may enable high-resolution quantification of longitudinal vascular changes as a method for studying zebrafish models of retinal neovascularization and vascular remodeling.

  7. Paediatric secondary intraocular lens estimation from the aphakic refraction alone: comparison with a standard biometric technique.

    PubMed

    Khan, A O; AlGaeed, A

    2006-12-01

    To compare the following two methods of paediatric secondary posterior chamber intraocular lens (PCIOL) determination with the Holladay formula: (1) estimation from the aphakic refraction alone (using assumed keratometry (K) of 44 diopters); and (2) calculation based on preoperative measured biometry. (1) Retrospective medical record review in a referral eye hospital of children with aphakia aged < or =12 years who underwent secondary PCIOL implantation with an Alcon MA60BM lens; (2) PCIOL determination for a plano refraction by the above two methods (estimation and calculation); and (3) prediction of pseudophakic refraction for the PCIOL actually implanted by the above two methods compared with the actual pseudophakic refraction. 50 eyes of 30 children with aphakia were studied. The estimated (mean, 95% confidence interval (CI)) secondary PCIOL values (25.81, +/-1.65 D) and the calculated secondary PCIOL values (26.35, +/-1.50 D) were not significantly different (mean absolute value of the difference 1.86 D, 95% CI +/-0.41 D) by the two-tailed paired t test at alpha = 0.05 (p = 0.11). For each eye, the pseudophakic refractions predicted by the two methods for the PCIOL that was actually implanted differed, both from each other and from the actual pseudophakic refraction (repeated-measures analysis of variance, p<0.001; Tukey test, p<0.01). The method of PCIOL estimation from the aphakic refraction alone provides values similar to those obtained by a standard technique and can be useful if biometry is unavailable. Targeting a pseudophakic refraction in paediatric aphakia is prone to error.

  8. [Report from the CFEF seminar on fetal biometry (June 2017)].

    PubMed

    Collège Français d'échographie Fœtale Cfef

    2017-10-01

    This article reports the conclusions and recommendations resulting from the seminar organized in Paris on June 15, 2017 by the scientific committee of the French College of Fetal Ultrasound (CFEF). The purpose of this meeting was to audit the practices in screening for SGA and IUGR fetuses in France and to discuss ways to improve ultrasound screening. A review of charts, references, standards and common practices was performed. The potential new biometric tools applicable in France were reviewed and analyzed. Eventually, options and recommendations for improvement are proposed. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. Keratometry obtained by corneal mapping versus the IOLMaster in the prediction of postoperative refraction in routine cataract surgery.

    PubMed

    Dulku, Simon; Smith, Henry B; Antcliff, Richard J

    2013-01-01

    To establish whether simulated keratometry values obtained by corneal mapping (videokeratography) would provide a superior refractive outcome to those obtained by Zeiss IOLMaster (partial coherence interferometry) in routine cataract surgery. Prospective, non-randomized, single-surgeon study set at the The Royal United Hospital, Bath, UK, District General Hospital. Thirty-three patients undergoing routine cataract surgery in the absence of significant ocular comorbidity. Conventional biometry was recorded using the Zeiss IOLMaster. Postoperative refraction was calculated using the SRK/T formula and the most appropriate power of lens implanted. Preoperative keratometry values were also obtained using Humphrey Instruments Atlas Version A6 corneal mapping. Achieved refraction was compared with predicted refraction for the two methods of keratometry after the A-constants were optimized to obtain a mean arithmetic error of zero dioptres for each device. The mean absolute prediction error was 0.39 dioptres (standard deviation 0.29) for IOLMaster and 0.48 dioptres (standard deviation 0.31) for corneal mapping (P = 0.0015). Keratometry readings between the devices were highly correlated by Spearman correlation (0.97). The Bland-Altman plot demonstrated close agreement between keratometers, with a bias of 0.0079 dioptres and 95% limits of agreement of -0.48-0.49 dioptres. The IOLMaster was superior to Humphrey Atlas A6 corneal mapping in the prediction of postoperative refraction. This difference could not have been predicted from the keratometry readings alone. When comparing biometry devices, close agreement between readings should not be considered a substitute for actual postoperative refraction data. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  10. B-mode ultrasonography biometry of the Amazon Parrot (Amazona aestiva) eye.

    PubMed

    Lehmkuhl, Ricardo C; Almeida, Mariana F; Mamprim, Maria J; Vulcano, Luiz C

    2010-09-01

    Ultrasonographic evaluation of the eye is a relatively recent addition to routine ophthalmic diagnostics in small animal ophthalmology. Some parameters for ophthalmic biometry have been established. There are few studies in clinical avian ophthalmology that describe ultrasound images of eye in some nocturnal avian species and in other birds that do not belong to the Brazilian fauna, but the psittacine family is not represented. The purpose of this study was to describe the following measurements: the distances between cornea and anterior lens capsule (D1) between the anterior and posterior lens capsule (D2), between posterior lens capsule and optic papilla (D3) and the axial length. Sixty four transpalpebral ocular ultrasound examinations were performed on 32 Blue fronted Amazon parrots (Amazona aestiva) with no history of previous ophthalmic disease. The measurements were taken in sagital planes using a 10 MHz linear probe without a standoff pad. The mean values for the left eye were; D1 0.17 ± 0.03 cm, D2 0.35 ± 0.02 cm, D3 0.73 ± 0.04 cm and the axial length 1.26 ± 0.06 cm. In the right eye D1 0.17 ± 0.02 cm, D2 0.34 ± 0.02 cm, D3 0.74 ± 0.03 cm and the axial length 1.25 ± 0.05 cm. No significant statistical difference was observed among the birds or between the left and right eye. The description of these parameters will allow the veterinary practitioner to evaluate the structural changes that specific diseases may cause in these animals.

  11. A model for predicting sulcus-to-sulcus diameter in posterior chamber phakic intraocular lens candidates: correlation between ocular biometric parameters.

    PubMed

    Ghoreishi, Mohammad; Abdi-Shahshahani, Mehdi; Peyman, Alireza; Pourazizi, Mohsen

    2018-02-21

    The aim of this study was to determine the correlation between ocular biometric parameters and sulcus-to-sulcus (STS) diameter. This was a cross-sectional study of preoperative ocular biometry data of patients who were candidates for phakic intraocular lens (IOL) surgery. Subjects underwent ocular biometry analysis, including refraction error evaluation using an autorefractor and Orbscan topography for white-to-white (WTW) corneal diameter and measurement. Pentacam was used to perform WTW corneal diameter and measurements of minimum and maximum keratometry (K). Measurements of STS and angle-to-angle (ATA) were obtained using a 50-MHz B-mode ultrasound device. Anterior optical coherence tomography was performed for anterior chamber depth measurement. Pearson's correlation test and stepwise linear regression analysis were used to find a model to predict STS. Fifty-eight eyes of 58 patients were enrolled. Mean age ± standard deviation of sample was 28.95 ± 6.04 years. The Pearson's correlation coefficient between STS with WTW, ATA, mean K was 0.383, 0.492, and - 0.353, respectively, which was statistically significant (all P < 0.001). Using stepwise linear regression analysis, there is a statistically significant association between STS with WTW (P = 0.011) and mean K (P = 0.025). The standardized coefficient was 0.323 and - 0.284 for WTW and mean K, respectively. The stepwise linear regression analysis equation was: (STS = 9.549 + 0.518 WTW - 0.083 mean K). Based on our result, given the correlation of STS with WTW and mean K and potential of direct and essay measurement of WTW and mean K, it seems that current IOL sizing protocols could be estimating with WTW and mean K.

  12. Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometer.

    PubMed

    Huang, Jinhai; Savini, Giacomo; Wu, Fan; Yu, Xinxin; Yang, Jing; Yu, Ayong; Yu, Ye; Wang, Qinmei

    2015-10-01

    To assess the precision of ocular biometry with a new noncontact optical low-coherence interferometer (Aladdin) in healthy subjects and patients with cataracts. Eye Hospital of Wenzhou Medical University, Wenzhou, China. Observational cross-sectional study. Eyes from healthy subjects and eyes from patients with cataracts were examined with the new interferometer. Axial length (AL), anterior chamber depth (ACD), keratometry (K), and white-to-white (WTW) values were measured by 2 operators. The test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability. Different-operator comparison was analyzed with paired t tests and Bland-Altman plots to assess interoperator reproducibility. Ninety-eight people were enrolled for this study, of which 52 eyes were from healthy subjects and 46 eyes were from patients with cataracts. The AL was the most repeatable and reproducible parameter. The ACD, K values, and WTW measurements were highly repeatable in healthy subjects with CoV less than 0.89% and ICC more than 0.94. However, in patients with cataracts, high repeatability could only be observed for AL, ACD, and K values, whereas WTW measurement had test-retest repeatability of 0.80 mm and an ICC of 0.795. Bland-Altman analysis also showed good agreement between the 2 operators for ocular component measurements, except that the WTW in patients with cataracts had wider 95% limits of agreement (range -0.88 to 0.95 mm). The new biometer showed excellent intraoperator repeatability and interoperator reproducibility for AL, ACD, and K values measurements in both groups. The precision of WTW measurements was lower in patients with cataracts. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Association of prenatal lipid-based nutritional supplementation with fetal growth in rural Gambia.

    PubMed

    Johnson, William; Darboe, Momodou K; Sosseh, Fatou; Nshe, Patrick; Prentice, Andrew M; Moore, Sophie E

    2017-04-01

    Prenatal supplementation with protein-energy (PE) and/or multiple-micronutrients (MMNs) may improve fetal growth, but trials of lipid-based nutritional supplements (LNSs) have reported inconsistent results. We conducted a post-hoc analysis of non-primary outcomes in a trial in Gambia, with the aim to test the associations of LNS with fetal growth and explore how efficacy varies depending on nutritional status. The sample comprised 620 pregnant women in an individually randomized, partially blinded trial with four arms: (a) iron and folic acid (FeFol) tablet (usual care, referent group), (b) MMN tablet, (c) PE LNS, and (d) PE + MMN LNS. Analysis of variance examined unadjusted differences in fetal biometry z-scores at 20 and 30 weeks and neonatal anthropometry z-scores, while regression tested for modification of intervention-outcome associations by season and maternal height, body mass index, and weight gain. Despite evidence of between-arm differences in some fetal biometry, z-scores at birth were not greater in the intervention arms than the FeFol arm (e.g., birth weight z-scores: FeFol -0.71, MMN -0.63, PE -0.64, PE + MMN -0.62; group-wise p = .796). In regression analyses, intervention associations with birth weight and head circumference were modified by maternal weight gain between booking and 30 weeks gestation (e.g., PE + MMN associations with birth weight were +0.462 z-scores (95% CI [0.097, 0.826]) in the highest quartile of weight gain but -0.099 z-scores (-0.459, 0.260) in the lowest). In conclusion, we found no strong evidence that a prenatal LNS intervention was associated with better fetal growth in the whole sample. © 2016 The Authors. Maternal & Child Nutrition published by John Wiley & Sons Ltd.

  14. Evidence Based Medicine in Space Flight: Evaluation of Inflight Vision Data for Operational Decision-Making

    NASA Technical Reports Server (NTRS)

    Van Baalen, Mary; Mason, Sara; Foy, Millennia; Wear, Mary; Taiym, Wafa; Moynihan, Shannan; Alexander, David; Hart, Steve; Tarver, William

    2015-01-01

    Due to recently identified vision changes associated with space flight, JSC Space and Clinical Operations (SCO) implemented broad mission-related vision testing starting in 2009. Optical Coherence Tomography (OCT), 3 Tesla Brain and Orbit MRIs, Optical Biometry were implemented terrestrially for clinical monitoring. While no inflight vision testing was in place, already available onorbit technology was leveraged to facilitate in-flight clinical monitoring, including visual acuity, Amsler grid, tonometry, and ultrasonography. In 2013, on-orbit testing capabilities were expanded to include contrast sensitivity testing and OCT. As these additional testing capabilities have been added, resource prioritization, particularly crew time, is under evaluation.

  15. BOREAS TE-6 Allometry Data

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Papagno, Andrea (Editor); Gower, Stith T.; Vogel, Jason G.

    2000-01-01

    The BOREAS TE-6 team collected several data sets in support of its efforts to characterize and interpret information on the plant biomass, allometry, biometry, sapwood, leaf area index, net primary production, soil temperature, leaf water potential, soil CO2 flux, and multivegetation imagery of boreal vegetation. This data set includes tree measurements conducted on the above-ground biomass of trees in the BOREAS NSA and SSA during the growing seasons of 1994 and 1995 and the derived allometric relationships/equations. The data are stored in ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distrobuted Activity Archive Center (DAAC).

  16. BOREAS TE-6 Biomass and Foliage Area Data

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Papagno, Andrea (Editor); Gower, Stith T.; Vogel, Jason G.

    2000-01-01

    The BOREAS TE-6 team collected several data sets in support of its efforts to characterize and interpret information on the plant biomass, allometry, biometry, sapwood, leaf area index, net primary production, soil temperature, leaf water potential, soil CO, flux, and multivegetation imagery of boreal vegetation. This data set contains measurements of estimates of the standing biomass and leaf area index for the plant species at the TF, CEV, and AUX sites in the SSA and NSA during the growing seasons of 1994 and 1995. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).

  17. 3-D Human body models in C.A.D. : Anthropometric Aspects

    NASA Astrophysics Data System (ADS)

    Renaud, C.; Steck, R.; Pineau, J. C.

    1986-07-01

    Modeling and simulation methods of man-machine systems are developed at the laboratory by interactive infography and C.A.D. technics. In order to better apprehend the morphological variability of populations we have enriched the 3-D model with a parametric function using classical anthropometric dimensions. We have selected reference, associate and complementary dimensions : lengths, breadths, circumferences and depths, which depend on operator's tasks and characteristics of workplaces. All anthropometric values come from the International Data Bank of Human Biometry of ERGODATA System. The utilization of the parametric function brings a quick and accurate description of morphology for theoretic subjects and can be used in C.A.D. analysis.

  18. Pros and cons of immediately sequential bilateral cataract surgery (ISBCS).

    PubMed

    Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Claoué, Charles

    2016-01-01

    Immediately sequential bilateral cataract surgery (ISBCS) is currently a "hot topic" in ophthalmology. There are well-documented advantages in terms of quicker visual rehabilitation and reduced costs. The risk of bilateral simultaneous endophthalmitis and bilateral blindness is now recognized to be minuscule with the advent of intracameral antibiotics and modern management of endophthalmitis. Refractive surprises are rare for normal eyes and with the use of optical biometry. Where a general anesthetic is indicated for cataract surgery, the risk of death from a second anesthetic is much higher than the risk of blindness. A widely recognized protocol from the International Society of Bilateral Cataract Surgeons needs to be adhered to if surgeons wish to start practicing ISBCS.

  19. Biometric identity management for standard mobile medical networks.

    PubMed

    Egner, Alexandru; Soceanu, Alexandru; Moldoveanu, Florica

    2012-01-01

    The explosion of healthcare costs over the last decade has prompted the ICT industry to respond with solutions for reducing costs while improving healthcare quality. The ISO/IEEE 11073 family of standards recently released is the first step towards interoperability of mobile medical devices used in patient environments. The standards do not, however, tackle security problems, such as identity management, or the secure exchange of medical data. This paper proposes an enhancement of the ISO/IEEE 11073-20601 protocol with an identity management system based on biometry. The paper describes a novel biometric-based authentication process, together with the biometric key generation algorithm. The proposed extension of the ISO/IEEE 11073-20601 is also presented.

  20. Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch

    PubMed Central

    Ruggeri, Marco; Uhlhorn, Stephen R.; De Freitas, Carolina; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie

    2012-01-01

    Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time. PMID:22808424

  1. Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch.

    PubMed

    Ruggeri, Marco; Uhlhorn, Stephen R; De Freitas, Carolina; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie

    2012-07-01

    An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time.

  2. Detection of a de novo Y278C mutation in FGFR3 in a pregnancy with severe fetal hypochondroplasia: prenatal diagnosis and literature review.

    PubMed

    Chen, Chih-Ping; Su, Yi-Ning; Lin, Tzu-Hung; Chang, Tung-Yao; Su, Jun-Wei; Wang, Wayseen

    2013-12-01

    We describe a prenatal molecular diagnosis of hypochondroplasia (HCH) in a pregnancy not at risk of HCH and review the literature on prenatal diagnosis of HCH. A 28-year-old primigravid woman was referred for genetic counseling at 30 weeks of gestation because of short-limbed dwarfism in the fetus. The woman had a body height of 152 cm. Her husband had a body height of 180 cm. Level II ultrasound showed a normal amount of amniotic fluid and a singleton fetus with fetal biometry equivalent to 30 weeks except for short limbs. Fetal biometry measurements were as follows: biparietal diameter = 7.38 cm (30 weeks); head circumference = 28.14 cm (30 weeks); abdominal circumference (AC) = 24.64 cm (30 weeks); femur length (FL) = 3.97 cm (<5th centile); FL/AC ratio = 0.161 (normal > 0.18); humerus = 3.64 cm (<5th centile); radius = 3.49 cm (30 weeks); ulna = 3.76 cm (<5(th) centile); tibia = 3.67 cm (<5th centile); and fibula = 3.72 cm (<5th centile). The digits and craniofacial appearance were normal. A tentative diagnosis of achondroplasia (ACH) was made. DNA testing for the FGFR3 gene and whole-genome array comparative genomic hybridization (aCGH) analysis were performed using cord blood DNA obtained by cordocentesis. FGFR3 mutation analysis revealed a de novo heterozygous c.833A > G, TAC > TGC transversion in exon 7 leading to a p.Tyr278Cys (Y278C) mutation in the FGFR3 protein. aCGH analysis revealed no genomic imbalance in cord blood. After delivery, the fetus had short limbs, a narrow thorax, brachydactyly, and relative macrocephaly. Cytogenetic analysis of cultured placental cells revealed a karyotype of 46,XX. Prenatal diagnosis of abnormal ultrasound findings suspicious of ACH should include a differential diagnosis of HCH by molecular analysis of FGFR3. Copyright © 2013. Published by Elsevier B.V.

  3. Augmented uterine artery blood flow and oxygen delivery protect Andeans from altitude-associated reductions in fetal growth

    PubMed Central

    Julian, Colleen Glyde; Wilson, Megan J.; Lopez, Miriam; Yamashiro, Henry; Tellez, Wilma; Rodriguez, Armando; Bigham, Abigail W.; Shriver, Mark D.; Rodriguez, Carmelo; Vargas, Enrique; Moore, Lorna G.

    2009-01-01

    The effect of high altitude on reducing birth weight is markedly less in populations of high- (e.g., Andeans) relative to low-altitude origin (e.g., Europeans). Uterine artery (UA) blood flow is greater during pregnancy in Andeans than Europeans at high altitude; however, it is not clear whether such blood flow differences play a causal role in ancestry-associated variations in fetal growth. We tested the hypothesis that greater UA blood flow contributes to the protection of fetal growth afforded by Andean ancestry by comparing UA blood flow and fetal growth throughout pregnancy in 137 Andean or European residents of low (400 m; European n = 28, Andean n = 23) or high (3,100–4,100 m; European n = 51, Andean n = 35) altitude in Bolivia. Blood flow and fetal biometry were assessed by Doppler ultrasound, and maternal ancestry was confirmed, using a panel of 100 ancestry-informative genetic markers (AIMs). At low altitude, there were no ancestry-related differences in the pregnancy-associated rise in UA blood flow, fetal biometry, or birth weight. At high altitude, Andean infants weighed 253 g more than European infants after controlling for gestational age and other known influences. UA blood flow and O2 delivery were twofold greater at 20 wk in Andean than European women at high altitude, and were paralleled by greater fetal size. Moreover, variation in the proportion of Indigenous American ancestry among individual women was positively associated with UA diameter, blood flow, O2 delivery, and fetal head circumference. We concluded that greater UA blood flow protects against hypoxia-associated reductions in fetal growth, consistent with the hypothesis that genetic factors enabled Andeans to achieve a greater pregnancy-associated rise in UA blood flow and O2 delivery than European women at high altitude. PMID:19244584

  4. Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser: One-month results.

    PubMed

    Woodcock, Michael G; Lehmann, Robert; Cionni, Robert J; Breen, Michael; Scott, Maria C

    2016-06-01

    To compare astigmatic outcomes in patients with bilateral cataracts having toric intraocular lens (IOL) implantation with intraoperative aberrometry measurements in 1 eye and standard power calculation and a toric IOL calculator with inked axis marking in the contralateral eye. Twelve sites in the United States. Prospective cohort study. The eye with the more visually significant cataract was randomized to intraoperative aberrometry measurements (Ocular Response Analyzer with Verifeye) or standard preoperative biometry and use of a toric calculator with the contralateral eye automatically assigned to the other group. The primary effectiveness outcome was the proportion of eyes with a postoperative refractive astigmatism of 0.50 diopter (D) or less at 1 month. Of the 130 patients (260 eyes) enrolled, 124 (248 eyes) were randomized; 121 (242 eyes) completed the trial. The percentage of eyes with astigmatism of 0.50 D or less at 1 month was higher in the intraoperative aberrometry group than in the standard group (89.2% versus 76.6%) (P = .006). The mean postoperative refractive astigmatism was lower in the intraoperative aberrometry group (0.29 D ± 0.28 [SD] versus 0.36 ± 0.35 D) (P = .041). Secondary effectiveness endpoints, including manifest refraction spherical equivalent prediction error, uncorrected distance visual acuity, and corrected distance visual acuity, were similar. Compared with standard methods, the use of the intraoperative aberrometry system increased the proportion of eyes with postoperative refractive astigmatism of 0.50 D or less and reduced the mean postoperative refractive astigmatism at 1 month. Other efficacy outcomes were similar. Drs. Woodcock, Lehmann, and Cionni are consultants to Alcon Laboratories, Inc. Dr. Breen is an employee of Alcon Laboratories, Inc. Dr. Scott has no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

    PubMed

    Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin

    2017-08-01

    The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.

  6. Predicting Accommodative Response Using Paraxial Schematic Eye Models

    PubMed Central

    Ramasubramanian, Viswanathan; Glasser, Adrian

    2016-01-01

    Purpose Prior ultrasound biomicroscopy (UBM) studies showed that accommodative optical response (AOR) can be predicted from accommodative biometric changes in a young and a pre-presbyopic population from linear relationships between accommodative optical and biometric changes, with a standard deviation of less than 0.55D. Here, paraxial schematic eyes (SE) were constructed from measured accommodative ocular biometry parameters to see if predictions are improved. Methods Measured ocular biometry (OCT, A-scan and UBM) parameters from 24 young and 24 pre-presbyopic subjects were used to construct paraxial SEs for each individual subject (individual SEs) for three different lens equivalent refractive index methods. Refraction and AOR calculated from the individual SEs were compared with Grand Seiko (GS) autorefractor measured refraction and AOR. Refraction and AOR were also calculated from individual SEs constructed using the average population accommodative change in UBM measured parameters (average SEs). Results Schematic eye calculated and GS measured AOR were linearly related (young subjects: slope = 0.77; r2 = 0.86; pre-presbyopic subjects: slope = 0.64; r2 = 0.55). The mean difference in AOR (GS - individual SEs) for the young subjects was −0.27D and for the pre-presbyopic subjects was 0.33D. For individual SEs, the mean ± SD of the absolute differences in AOR between the GS and SEs was 0.50 ± 0.39D for the young subjects and 0.50 ± 0.37D for the pre-presbyopic subjects. For average SEs, the mean ± SD of the absolute differences in AOR between the GS and the SEs was 0.77 ± 0.88D for the young subjects and 0.51 ± 0.49D for the pre-presbyopic subjects. Conclusions Individual paraxial SEs predict AOR, on average, with a standard deviation of 0.50D in young and pre-presbyopic subject populations. Although this prediction is only marginally better than from individual linear regressions, it does consider all the ocular biometric parameters. PMID:27092928

  7. Longitudinal changes in fetal biometry and cerebroplacental hemodynamics in fetuses with congenital heart disease.

    PubMed

    Ruiz, A; Cruz-Lemini, M; Masoller, N; Sanz-Cortés, M; Ferrer, Q; Ribera, I; Martínez, J M; Crispi, F; Arévalo, S; Gómez, O; Pérez-Hoyos, S; Carreras, E; Gratacós, E; Llurba, E

    2017-03-01

    To determine the longitudinal behavior of fetal biometric measures and cerebroplacental hemodynamics throughout gestation in fetuses with congenital heart disease (CHD). Fetal biometry and Doppler hemodynamics (uterine artery (UtA), umbilical artery (UA) and fetal middle cerebral artery (MCA)) were measured serially in a cohort of consecutive fetuses diagnosed with CHD. Evaluations were made at various time points, from diagnosis (20-25 weeks) to delivery, with at least two measurements per fetus that were at least 2 weeks apart. Fetuses were classified into three groups according to the pattern of blood supply to the brain (placental vs systemic) that would be expected on the basis of the type of CHD. All parameters were transformed into Z-scores. A linear mixed model to analyze repeated measurements was constructed for each parameter to assess its behavior throughout gestation. Four hundred and forty-four ultrasound examinations were performed in 119 CHD fetuses, with a median of two measurements per fetus. The fetuses presented a small head at diagnosis (biparietal diameter (BPD) Z-score, -1.32 ± 0.99; head circumference (HC) Z-score, -0.79 ± 1.02), which remained small throughout gestation. UtA and UA pulsatility indices (PI) showed a significant increase towards the end of pregnancy, whereas no significant changes were observed in MCA-PI or cerebroplacental ratio (CPR) with gestational age. Both MCA and CPR presented significant differences in longitudinal behavior between CHD groups, while BPD and HC did not. CHD fetuses have a relatively small head from the second trimester of pregnancy, regardless of the type of CHD anomaly, and increasing resistance in the UtA and UA as pregnancy progresses, suggestive of increasing degree of placental impairment. Our findings indicate the early onset of mechanisms that could lead to poorer neurodevelopment later in life. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  8. Preterm or not--an evaluation of estimates of gestational age in a cohort of women from Rural Papua New Guinea.

    PubMed

    Karl, Stephan; Li Wai Suen, Connie S N; Unger, Holger W; Ome-Kaius, Maria; Mola, Glen; White, Lisa; Wangnapi, Regina A; Rogerson, Stephen J; Mueller, Ivo

    2015-01-01

    Knowledge of accurate gestational age is required for comprehensive pregnancy care and is an essential component of research evaluating causes of preterm birth. In industrialised countries gestational age is determined with the help of fetal biometry in early pregnancy. Lack of ultrasound and late presentation to antenatal clinic limits this practice in low-resource settings. Instead, clinical estimators of gestational age are used, but their accuracy remains a matter of debate. In a cohort of 688 singleton pregnancies from rural Papua New Guinea, delivery gestational age was calculated from Ballard score, last menstrual period, symphysis-pubis fundal height at first visit and quickening as well as mid- and late pregnancy fetal biometry. Published models using sequential fundal height measurements and corrected last menstrual period to estimate gestational age were also tested. Novel linear models that combined clinical measurements for gestational age estimation were developed. Predictions were compared with the reference early pregnancy ultrasound (<25 gestational weeks) using correlation, regression and Bland-Altman analyses and ranked for their capability to predict preterm birth using the harmonic mean of recall and precision (F-measure). Average bias between reference ultrasound and clinical methods ranged from 0-11 days (95% confidence levels: 14-42 days). Preterm birth was best predicted by mid-pregnancy ultrasound (F-measure: 0.72), and neuromuscular Ballard score provided the least reliable preterm birth prediction (F-measure: 0.17). The best clinical methods to predict gestational age and preterm birth were last menstrual period and fundal height (F-measures 0.35). A linear model combining both measures improved prediction of preterm birth (F-measure: 0.58). Estimation of gestational age without ultrasound is prone to significant error. In the absence of ultrasound facilities, last menstrual period and fundal height are among the more reliable clinical measures. This study underlines the importance of strengthening ultrasound facilities and developing novel ways to estimate gestational age.

  9. Clinical and biometric determinants of actual lens position after cataract surgery.

    PubMed

    Plat, Julien; Hoa, Didier; Mura, Frederic; Busetto, Timothe; Schneider, Christelle; Payerols, Arnaud; Villain, Max; Daien, Vincent

    2017-02-01

    To evaluate the preoperative clinical and biometric determinants associated with the actual lens position after cataract surgery. Department of Ophthalmology, University Hospital of Montpellier, France. Prospective longitudinal cohort study. The data collected included clinical factors (age, sex, history of vitrectomy) and biometry factors (axial length [AL], anterior chamber depth [ACD], lens thickness, white-to-white [WTW] distance) that might affect actual lens position. Each patient had optical low-coherence reflectometry biometry (Lenstar) preoperatively and 1 month postoperatively. The actual lens position was measured as the postoperative position of the center of the intraocular lens (IOL). Patients were stratified into 3 groups by type of IOL: Acrysof SN60WF or SN6AT (Group 1), Tecnis ZCB00 or ZCT (Group 2), and Asphina 409 MV (Group 3). The study comprised 168 eyes (mean age 73.3 years ± 9.8 [SD]). The mean actual lens position was 4.88 ± 0.29 mm, 5.01 ± 0.29 mm, and 5.05 ± 0.32 mm in Group 1 (n = 67 eyes), Group 2 (n = 52 eyes), and Group 3 (n = 49 eyes), respectively. In the overall population, AL, ACD, anterior segment depth, and WTW distance were correlated with actual lens position (r = 0.48, P < .0001; r = 0.64, P < .001; r = 0.58, P < .0001; r = 0.39, P < .001, respectively). The AL, ACD, anterior segment depth, and WTW distance correlated with actual lens position after cataract surgery. The integration of these data in IOL formulas could help improve refractive outcomes after the surgery. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. B-mode and Doppler sonography of the mammary glands in dairy goats for mastitis diagnosis.

    PubMed

    Santos, Vjc; Simplício, K; Sanchez, D; Coutinho, L; Teixeira, P; Barros, F; Almeida, V; Rodrigues, L; Bartlewski, P; Oliveira, M; Feliciano, M; Vicente, W

    2015-04-01

    This study aimed to evaluate the sonographic characteristics of the udder and teats and to determine the Doppler indexes of mammary artery in healthy and undergoing subclinical and clinical mastitis goats. Thirty animals among Saanen and Alpine Brown goats were arranged in three groups, healthy goats (HG), goats with subclinical mastitis (SMG) and goats with clinical mastitis (CMG). Using the B-mode, the sonographic characteristics (echotexture and echogenicity) and biometry (diameter and area of the udder cistern, diameter and area of the teat cistern and thickness of the teat wall) were evaluated. Using Doppler ultrasonography, the vascular indexes of the mammary artery were obtained. It was observed hyperechogenicity with solid component in the gland cistern when comparing animals with clinical mastitis and healthy mammary tissue. Regarding the echotexture of the breast tissue, there was heterogeneity in the mammary parenchyma on the three groups, for the milk, it was observed homogeneity for animals on HG and SMG and heterogeneity for animals on CMG. Grey-scale quantitative assessment revealed increase in echogenicity (mean value) for all the structures when comparing the three groups. Biometry did not reveal statistical difference between groups, for none of the evaluated structures. Doppler examination of the mammary artery showed the decrease of end diastolic velocity and raise of pulsatility index between groups. The association of B-mode and Doppler ultrasonography is useful for the evaluation of the udder of dairy goats with mastitis. It is a sensitive and specific method for the study of this disease. Doppler mode was unable to establish reliable criteria for diagnosis of subclinical mastitis. Moreover, the quantification of echogenicity is a useful technique for the evaluation of the milk in animals with mastitis; therefore, it is suggested that it can be used as complementary technique for the diagnosis of mastitis in goats. © 2015 Blackwell Verlag GmbH.

  11. Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

    PubMed

    Özcura, Fatih; Aktaş, Serdar; Sağdık, Hacı Murat; Tetikoğlu, Mehmet

    2016-10-01

    The purpose of the study was to compare the accuracy of various biometric formulas for predicting postoperative refraction determined using applanation A-scan ultrasound. This retrospective comparative study included 485 eyes that underwent uneventful phacoemulsification with intraocular lens (IOL) implantation. Applanation A-scan ultrasound biometry and postoperative manifest refraction were obtained in all eyes. Biometric data were entered into each of the five IOL power calculation formulas: SRK-II, SRK/T, Holladay I, Hoffer Q, and Binkhorst II. All eyes were divided into three groups according to axial length: short (≤22.0 mm), average (22.0-25.0 mm), and long (≥25.0 mm) eyes. The postoperative spherical equivalent was calculated and compared with the predicted refractive error using each biometric formula. The results showed that all formulas had significantly lower mean absolute error (MAE) in comparison with Binkhorst II formula (P < 0.01). The lowest MAE was obtained with the SRK-II for average (0.49 ± 0.40 D) and short (0.67 ± 0.54 D) eyes and the SRK/T for long (0.61 ± 0.50 D) eyes. The highest postoperative hyperopic shift was seen with the SRK-II for average (46.8 %), short (28.1 %), and long (48.4 %) eyes. The highest postoperative myopic shift was seen with the Holladay I for average (66.4 %) and long (71.0 %) eyes and the SRK/T for short eyes (80.6 %). In conclusion, the SRK-II formula produced the lowest MAE in average and short eyes and the SRK/T formula produced the lowest MAE in long eyes. The SRK-II has the highest postoperative hyperopic shift in all eyes. The highest postoperative myopic shift is with the Holladay I for average and long eyes and SRK/T for short eyes.

  12. Memorandum "Open Metadata". Open Access to Documentation Forms and Item Catalogs in Healthcare.

    PubMed

    Dugas, M; Jöckel, K-H; Friede, T; Gefeller, O; Kieser, M; Marschollek, M; Ammenwerth, E; Röhrig, R; Knaup-Gregori, P; Prokosch, H-U

    2015-01-01

    At present, most documentation forms and item catalogs in healthcare are not accessible to the public. This applies to assessment forms of routine patient care as well as case report forms (CRFs) of clinical and epidemiological studies. On behalf of the German chairs for Medical Informatics, Biometry and Epidemiology six recommendations to developers and users of documentation forms in healthcare were developed. Open access to medical documentation forms could substantially improve information systems in healthcare and medical research networks. Therefore these forms should be made available to the scientific community, their use should not be unduly restricted, they should be published in a sustainable way using international standards and sources of documentation forms should be referenced in scientific publications.

  13. Growth oscillation in larger foraminifera.

    PubMed

    Briguglio, Antonino; Hohenegger, Johann

    2014-01-01

    This work shows the potential for applying three-dimensional biometry to studying cell growth in larger benthic foraminifera. The volume of each test chamber was measured from the three-dimensional model obtained by means of computed tomography. Analyses of cell growth based on the sequence of chamber volumes revealed constant and significant oscillations for all investigated specimens, characterized by periods of approximately 15, 30, 90, and 360 days. Possible explanations for these periods are connected to tides, lunar cycles, and seasonality. The potential to record environmental oscillations or fluctuations during the lifetime of larger foraminifera is pivotal for reconstructing short-term paleoenvironmental variations or for gaining insight into the influence of tides or tidal current on the shallow-water benthic fauna in both recent and fossil environments.

  14. Clinical study of the Erlanger silver catheter--data management and biometry.

    PubMed

    Martus, P; Geis, C; Lugauer, S; Böswald, M; Guggenbichler, J P

    1999-01-01

    The clinical evaluation of venous catheters for catheter-induced infections must conform to a strict biometric methodology. The statistical planning of the study (target population, design, degree of blinding), data management (database design, definition of variables, coding), quality assurance (data inspection at several levels) and the biometric evaluation of the Erlanger silver catheter project are described. The three-step data flow included: 1) primary data from the hospital, 2) relational database, 3) files accessible for statistical evaluation. Two different statistical models were compared: analyzing the first catheter only of a patient in the analysis (independent data) and analyzing several catheters from the same patient (dependent data) by means of the generalized estimating equations (GEE) method. The main result of the study was based on the comparison of both statistical models.

  15. Relationship between axial length of the emmetropic eye and the age, body height, and body weight of schoolchildren.

    PubMed

    Selović, Alen; Juresa, Vesna; Ivankovic, Davor; Malcic, Davor; Selović Bobonj, Gordana

    2005-01-01

    This report assesses the relationship of axial length of emmetropic (without refractive error) eyes to age, height, and weight in 1,600 Croatian schoolchildren. Axial eye lengths were determined by an ultrasonic eye biometry (A scan). Axial length of both eyes increases with age, height, and weight but shows a closer correlation to height and weight than to age. Boys have a significantly longer axial eye length than girls (P < 0.01). Boys or girls of similar or nearing body height and body weight and with emmetropic eyes have close linear measures of anatomic eye structures within their sex, regardless their age. Body height demonstrates the closest correlation to the growth and development of the emmetropic eye. Copyright 2005 Wiley-Liss, Inc.

  16. Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths.

    PubMed

    Karabela, Yunus; Eliacik, Mustafa; Kaya, Faruk

    2016-07-08

    The SRK/T formula is one of the third generation IOL calculation formulas. The purpose of this study was to evaluate the performance of the SRK/T formula in predicting a target refraction ±1.0D in short and long eyes using ultrasound biometry after phacoemulsification. The present study was a retrospective analysis, which included 38 eyes with an AL < 22.0 mm (short AL), and 62 eyes ≥24.6 mm (long AL) that underwent uncomplicated phacoemulsification. Preoperative AL was measured by ultrasound biometry and SRK/T formula was used for IOL calculation. Three different IOLs were implanted in the capsular bag. The prediction error was defined as the difference between the achieved postoperative refraction, and attempted predicted target refraction. Statistical analysis was performed with SPSS V21. In short ALs, the mean age was 65.13 ± 9.49 year, the mean AL was 21.55 ± 0.45 mm, the mean K1 and K2 were 45.76 ± 1.77D and 46.09 ± 1.61D, the mean IOL power was 23.96 ± 1.92D, the mean attempted (predicted) value was 0.07 ± 0.26D, the mean achieved value was 0.07 ± 0.63 D, the mean PE was 0.01 ± 0.60D, and the MAE was 0.51 ± 0.31D. A significant positive relationship with AL and K1, K2, IOL power and a strong negative relationship with PE and achieved postoperative was found. In long ALs, the mean age was 64.05 ± 7.31 year, the mean AL was 25.77 ± 1.64 mm, the mean K1 and K2 were 42.20 ± 1.57D and 42.17 ± 1.68D, the mean IOL power was 15.79 ± 5.17D, the mean attempted value was -0.434 ± 0.315D, the mean achieved value was -0.42 ± 0.96D, the mean PE was -0.004 ± 0.93D, the MAE was 0.68 ± 0.62D. A significant positive relationship with AL and K1, K2 and a significant positive relationship with PE and achieved value, otherwise a negative relationship with AL and IOL power was found. There was a little tendency towards hyperopic for short ALs and myopic for long ALs. The majority of eyes (94.74 %) for short ALs and (70.97 %) for long ALs were within ±1 D of the predicted refractive error. No significant relationship with PE and IOL types, AL, K1, K2, IOL power, and attempted value, besides with MAE and AL, K1, K2, age, attempted, achieved value were found in both groups. The SRK/T formula performs well and shows good predictability in eyes with short and long axial lengths.

  17. Performance of third-trimester ultrasound for prediction of small-for-gestational-age neonates and evaluation of contingency screening policies.

    PubMed

    Souka, A P; Papastefanou, I; Pilalis, A; Michalitsi, V; Kassanos, D

    2012-05-01

    To assess the performance of third-trimester fetal biometry and fetal Doppler studies for the prediction of small-for-gestational-age (SGA) neonates, and to explore contingency strategies using a first-trimester prediction model based on maternal and fetal parameters and third-trimester ultrasound. This was an observational cross-sectional study of uncomplicated singleton pregnancies. Risk assessment for chromosomal abnormality was carried out in 4702 pregnancies using a combination of ultrasound markers (fetal nuchal translucency thickness (NT) and nasal bone assessment) and biochemistry (free beta-human chorionic gonadotropin (β-hCG) and pregnancy-associated plasma protein-A (PAPP-A)) at 11 to 13 + 6 weeks. Maternal demographic characteristics and method of conception were recorded. Third-trimester (30-34 weeks) fetal biometry (biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL)) and umbilical artery (UA) and middle cerebral artery Doppler studies were performed routinely in a subgroup (n = 2310). Reference ranges for birth weight were constructed using the cohort of 4702 women, and neonates were classified as small (SGA, ≤ 5th centile) or appropriate (AGA) for gestational age. First-trimester, third-trimester and integrated first- and third-trimester prediction models for SGA were constructed using regression analysis and three different contingency strategies of rescanning in the third trimester were investigated. According to the areas under the receiver-operating characteristics curves (AUCs), AC (AUC = 0.85) and ultrasound-estimated fetal weight (EFW, AUC = 0.87) were equally good predictors of SGA. The model was marginally improved by the addition of UA Doppler, smoking status and first-trimester indices (free β-hCG and PAPP-A multiples of the median) (combined model, AUC = 0.88), but the difference was not statistically significant. A contingency strategy of rescanning 50% of the population in the third trimester according to the risk estimated by a first-trimester prediction model yielded a detection rate of 79% for a 25% screen-positive rate. Third-trimester ultrasound is effective in screening for SGA in uncomplicated pregnancies. The use of a contingency screening policy can reduce the need for unnecessary examinations. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  18. Digital holography applications in ophthalmology, biometry, and optical trapping characterization

    NASA Astrophysics Data System (ADS)

    Potcoava, Mariana Camelia

    This dissertation combines various holographic techniques with application on the two- and three-dimensional imaging of ophthalmic tissue, fingerprints, and microsphere samples with micrometer resolution. Digital interference holography (DIH) uses scanned wavelengths to synthesize short-coherence interference tomographic images. We used DIH for in vitro imaging of human optic nerve head and retina. Tomographic images were produced by superposition of holograms. Holograms were obtained with a signal-to-noise ratio of approximately 50 dB. Optic nerve head characteristics (shape, diameter, cup depth, and cup width) were quantified with a few micron resolution (4.06--4.8mum). Multiple layers were distinguishable in cross-sectional images of the macula. To our knowledge, this is the first report of DIH use to image human macular and optic nerve tissue. Holographic phase microscopy is used to produce images of thin film patterns left by latent fingerprints. Two or more holographic phase images with different wavelengths are combined for optical phase unwrapping of images of patent prints. We demonstrated digital interference holography images of a plastic print, and latent prints. These demonstrations point to significant contributions to biometry by using digital interference holography to identify and quantify Level 1 (pattern), Level 2 (minutia points), and Level 3 (pores and ridge contours). Quantitative studies of physical and biological processes and precise non-contact manipulation of nanometer/micrometer trapped objects can be effectuated with nanometer accuracy due to the development of optical tweezers. A three-dimensional gradient trap is produced at the focus position of a high NA microscope objective. Particles are trapped axially and laterally due to the gradient force. The particle is confined in a potential well and the trap acts as a harmonic spring. The elastic constant or the stiffness along any axis is determined from the particle displacements in time along each specific axis. Thus, we report the sensing of small particles using optical trapping in combination with the digital Gabor holography to calibrate the optical force and the position and of the copolymer microsphere in the x, y, z direction with nm precision.

  19. Potential adverse effects of antenatal melatonin as a treatment for intrauterine growth restriction: findings in pregnant sheep.

    PubMed

    González-Candia, Alejandro; Veliz, Marcelino; Araya, Claudio; Quezada, Sebastian; Ebensperger, Germán; Serón-Ferré, María; Reyes, Roberto V; Llanos, Aníbal J; Herrera, Emilio A

    2016-08-01

    Intrauterine growth restriction is a condition in which the fetus has a birthweight and/or length <10th percentile for the gestational age. Intrauterine growth restriction can be associated with various causes, among which is low uteroplacental perfusion and chronic hypoxia during gestation. Often, intrauterine growth-restricted fetuses have increased oxidative stress; therefore, agents that decrease oxidative stress and increase utero, placental, and umbilical perfusion have been proposed as a beneficial therapeutic strategy. In this scenario, melatonin acts as an umbilical vasodilator and a potent antioxidant that has not been evaluated in pregnancies under chronic hypoxia that induce fetal growth restriction. However, this neurohormone has been proposed as a pharmacologic therapy for complicated pregnancies. The aim of this study was to determine the effects of prenatal administration of melatonin during the last trimester of pregnancy on the biometry of the growth-restricted lambs because of developmental hypoxia. Further, we aimed to determine melatonin and cortisol levels and oxidative stress markers in plasma of pregnant ewes during the treatment. High-altitude pregnant sheep received either vehicle (n = 5; 5 mL 1.4% ethanol) or melatonin (n = 7; 10 mg/kg(-1)day(-1) in 5 mL 1.4% ethanol) daily during the last one-third of gestation. Maternal plasma levels of melatonin, cortisol, antioxidant capacity, and oxidative stress were determined along treatment. At birth, neonates were examined, weighed, and measured (biparietal diameter, abdominal diameter, and crown-rump length). Antenatal treatment with melatonin markedly decreased neonatal biometry and weight at birth. Additionally, melatonin treatment increased the length of gestation by 7.5% and shifted the time of delivery. Furthermore, the prenatal treatment doubled plasma levels of melatonin and cortisol and significantly improved the antioxidant capacity of the pregnant ewes. Our findings indicate that antenatal melatonin induces further intrauterine growth restriction but improves the maternal plasma antioxidant capacity. Additional studies should address the efficiency and safety of antenatal melatonin before clinical attempts on humans. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Six-year changes in refraction and related ocular biometric factors in an adult Chinese population.

    PubMed

    Han, Xiaotong; Guo, Xinxing; Lee, Pei Ying; Morgan, Ian G; He, Mingguang

    2017-01-01

    To investigate longitudinal changes in refraction and biometry in Chinese adults. Population-based prospective cohort study. 1817 subjects aged ≥ 35 years were randomly recruited from Yuexiu district, Guangzhou, China in 2008. Of which 1595 (87.8%) were reexamined in 2010 and 1427 (78.5%) were reexamined in 2014. Non-cycloplegic automated refraction and visual acuity test were performed at baseline and the 6-year follow-up examination for all participants. In addition, 50% of the participants were randomly selected for axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) measurements using non-contact partial coherence laser interferometry. Lens power (LP) was calculated with the Bennett's equation. A total of 1300 participants were included in current analysis (2008 mean [SD] age, 51.4 [10.6] years; 54.5% women). Mean change in spherical equivalence (SE) was +0.24 (95% confidence interval [CI], +0.19 to +0.30), +0.51 (95% CI, +0.46 to +0.57), +0.26 (95% CI, +0.15 to +0.38) and -0.05 (95% CI, -0.21 to +0.10) diopters (D) for individuals in the age groups of 35 to 44, 45 to 54, 55 to 64 and 65+ years at baseline, respectively. Corneal power, AL and LT increased while ACD and LP decreased during the follow-up. Baseline SE and changes in biometric factors could explain 97.2% of the variance in longitudinal SE change while LP solely could explain 65.2%. Six-year mean change in cylinder power was -0.16 (95% CI, -0.19 to -0.13) D, the axis of astigmatism changed from "with-the-rule" to "against-the-rule" in 16.4% of the participants and to "oblique" in 0.9%. This study confirms a hyperopic shift in the elderly before 65 years old and a myopic shift thereafter. Longitudinal refraction change could be well explained by corresponding biometry changes, especially LP. There is also a shift to "against-the-rule" astigmatism for the adult population.

  1. The biometric study in different stages of primary angle-closure glaucoma

    PubMed Central

    Chen, Y-Y; Chen, Y-Y; Sheu, S-J; Chou, P

    2013-01-01

    Purpose This study compared the general and ocular biometric characteristics of normal, primary angle closure (PAC), and primary angle-closure glaucoma (PACG) patients to better understand the possible relationship between differences in ocular parameters that might predict risk for PACG in PAC patients. Methods One hundred normal, 90 PAC, and 90 PACG eyes were retrospectively reviewed. General characteristics such as age, gender, body height, body weight, blood pressure, pulse, systemic diseases, and education level were recorded. Ocular findings included visual acuity, intraocular pressure, refraction, cup to disc ratio, and ocular biometry. Ocular biometry was obtained by A-scan ultrasonography (Digital A/B scan 5500; Sonomed Inc., Lake Success, NY, USA). The parameters recorded were anterior chamber depth (ACD), lens thickness (LT), axial length (AXL), lens/axial length factor (LAF), and relative lens position (RLP). Results Although the controls, PAC group, and PACG group were found to be significantly different in age (62.7±9.8; 65.3±7.5; and 66.0±7.4, respectively), there were no gender differences. With regard to ocular parameters, the ACD tended to decrease and the LT and LAF tended to increase from normal to PAC to PACG. The eyes of the PACG group had significantly shallower ACD (P<0.001) and thicker lens (P<0.001) than those of the PAC group. While PAC had similar lens position to the control group, PACG had more anteriorly positioned lens than the PAC group (P<0.001). Logistic regression analysis found a significant association between a decrease in ACD and increased risk of PACG (odds ratio (OR)=3.59 for 0.2 mm decrease in ACD) as well as a significant association between an increase in LT and increased risk of PACG (OR=1.30). Conclusions In addition to LT, a shallower ACD owing to a change in RLP may have a role in the progression from PAC to PACG. Owing to the differences of certain biometric characteristics between PAC and PACG, A-scan ultrasonography might potentially be used for the early detection of PACG in PAC eyes. PMID:23788204

  2. Ethnic differences in lens parameters measured by ocular biometry in a cataract surgery population.

    PubMed

    Wang, Dajiang; Amoozgar, Behzad; Porco, Travis; Wang, Zhen; Lin, Shan C

    2017-01-01

    To investigate whether differences exist in lens position and other lens parameters among major ethnic groups with cataractous eyes, which may help explain racial differences in angle closure risk. This retrospective, cross-sectional study included 807 adult patients who had cataract surgery between years 2014 and 2016 at the University of California, San Francisco (UCSF). Adult patients of white, Asian, Hispanic and African-American ethnicity were included. Lens position (LP), defined as anterior chamber depth (ACD) + 1/2 lens thickness (LT), was assessed using measurements from optical biometry. Other assessed biometric parameters included axial length (AL), relative lens position (RLP) (defined as LP/AL), and anterior chamber depth (ACD). A total of 807 patients and 1361 eyes were included in this study from a database of patients having cataract surgery. Mean age was 69.2 years (age range from 18 to 101 years old), and 60.3% of patients were women. The mean LP measurements were 5.54±0.32 mm for white, 5.38±0.32 mm for Asian, 5.32±0.30 mm for Hispanic, and 5.40±0.28 mm for African-American participants. After adjusting for age, sex, and AL, significant differences were found when comparing LP in paired comparisons among White cohort with Asians (P<0.001), Hispanics (P<0.001) and African-Americans (P = 0.003). Additionally, when comparing RLP, similar significant results were found when comparing Whites with Asians (P<0.001), Hispanics (P<0.001) and African-Americans (P = 0.002). Lastly, pair-wise comparison of LT between ethnic groups showed significant differences while comparing Asians with Whites (P = 0.001) and Asians with African-Americans (P<0.001). The results of this study suggest that the LP of Hispanic, Asian, and African-American patients are significantly smaller than that of White patients, and among all ethnic groups, Hispanics and after Asians have the smallest LP (P<0.001) and RLP (P<0.001). These findings may have implications for the relative risk of angle closure and the potential IOP response after cataract surgery among different ethnic groups.

  3. Six-year changes in refraction and related ocular biometric factors in an adult Chinese population

    PubMed Central

    Han, Xiaotong; Guo, Xinxing; Lee, Pei Ying; Morgan, Ian G.; He, Mingguang

    2017-01-01

    Purpose To investigate longitudinal changes in refraction and biometry in Chinese adults. Design Population-based prospective cohort study. Methods 1817 subjects aged ≥ 35 years were randomly recruited from Yuexiu district, Guangzhou, China in 2008. Of which 1595 (87.8%) were reexamined in 2010 and 1427 (78.5%) were reexamined in 2014. Non-cycloplegic automated refraction and visual acuity test were performed at baseline and the 6-year follow-up examination for all participants. In addition, 50% of the participants were randomly selected for axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) measurements using non-contact partial coherence laser interferometry. Lens power (LP) was calculated with the Bennett’s equation. Results A total of 1300 participants were included in current analysis (2008 mean [SD] age, 51.4 [10.6] years; 54.5% women). Mean change in spherical equivalence (SE) was +0.24 (95% confidence interval [CI], +0.19 to +0.30), +0.51 (95% CI, +0.46 to +0.57), +0.26 (95% CI, +0.15 to +0.38) and -0.05 (95% CI, -0.21 to +0.10) diopters (D) for individuals in the age groups of 35 to 44, 45 to 54, 55 to 64 and 65+ years at baseline, respectively. Corneal power, AL and LT increased while ACD and LP decreased during the follow-up. Baseline SE and changes in biometric factors could explain 97.2% of the variance in longitudinal SE change while LP solely could explain 65.2%. Six-year mean change in cylinder power was -0.16 (95% CI, -0.19 to -0.13) D, the axis of astigmatism changed from “with-the-rule” to “against-the-rule” in 16.4% of the participants and to “oblique” in 0.9%. Conclusions This study confirms a hyperopic shift in the elderly before 65 years old and a myopic shift thereafter. Longitudinal refraction change could be well explained by corresponding biometry changes, especially LP. There is also a shift to “against-the-rule” astigmatism for the adult population. PMID:28854269

  4. In vivo measurement of the average refractive index of the human crystalline lens using optical coherence tomography.

    PubMed

    de Freitas, Carolina; Ruggeri, Marco; Manns, Fabrice; Ho, Arthur; Parel, Jean-Marie

    2013-01-15

    We present a method for measuring the average group refractive index of the human crystalline lens in vivo using an optical coherence tomography (OCT) system which, allows full-length biometry of the eye. A series of OCT images of the eye including the anterior segment and retina were recorded during accommodation. Optical lengths of the anterior chamber, lens, and vitreous were measured dynamically along the central axis on the OCT images. The group refractive index of the crystalline lens along the central axis was determined using linear regression analysis of the intraocular optical length measurements. Measurements were acquired on three subjects of age 21, 24, and 35 years. The average group refractive index for the three subjects was, respectively, n=1.41, 1.43, and 1.39 at 835 nm.

  5. Using complex networks towards information retrieval and diagnostics in multidimensional imaging

    NASA Astrophysics Data System (ADS)

    Banerjee, Soumya Jyoti; Azharuddin, Mohammad; Sen, Debanjan; Savale, Smruti; Datta, Himadri; Dasgupta, Anjan Kr; Roy, Soumen

    2015-12-01

    We present a fresh and broad yet simple approach towards information retrieval in general and diagnostics in particular by applying the theory of complex networks on multidimensional, dynamic images. We demonstrate a successful use of our method with the time series generated from high content thermal imaging videos of patients suffering from the aqueous deficient dry eye (ADDE) disease. Remarkably, network analyses of thermal imaging time series of contact lens users and patients upon whom Laser-Assisted in situ Keratomileusis (Lasik) surgery has been conducted, exhibit pronounced similarity with results obtained from ADDE patients. We also propose a general framework for the transformation of multidimensional images to networks for futuristic biometry. Our approach is general and scalable to other fluctuation-based devices where network parameters derived from fluctuations, act as effective discriminators and diagnostic markers.

  6. Using complex networks towards information retrieval and diagnostics in multidimensional imaging.

    PubMed

    Banerjee, Soumya Jyoti; Azharuddin, Mohammad; Sen, Debanjan; Savale, Smruti; Datta, Himadri; Dasgupta, Anjan Kr; Roy, Soumen

    2015-12-02

    We present a fresh and broad yet simple approach towards information retrieval in general and diagnostics in particular by applying the theory of complex networks on multidimensional, dynamic images. We demonstrate a successful use of our method with the time series generated from high content thermal imaging videos of patients suffering from the aqueous deficient dry eye (ADDE) disease. Remarkably, network analyses of thermal imaging time series of contact lens users and patients upon whom Laser-Assisted in situ Keratomileusis (Lasik) surgery has been conducted, exhibit pronounced similarity with results obtained from ADDE patients. We also propose a general framework for the transformation of multidimensional images to networks for futuristic biometry. Our approach is general and scalable to other fluctuation-based devices where network parameters derived from fluctuations, act as effective discriminators and diagnostic markers.

  7. Using complex networks towards information retrieval and diagnostics in multidimensional imaging

    PubMed Central

    Banerjee, Soumya Jyoti; Azharuddin, Mohammad; Sen, Debanjan; Savale, Smruti; Datta, Himadri; Dasgupta, Anjan Kr; Roy, Soumen

    2015-01-01

    We present a fresh and broad yet simple approach towards information retrieval in general and diagnostics in particular by applying the theory of complex networks on multidimensional, dynamic images. We demonstrate a successful use of our method with the time series generated from high content thermal imaging videos of patients suffering from the aqueous deficient dry eye (ADDE) disease. Remarkably, network analyses of thermal imaging time series of contact lens users and patients upon whom Laser-Assisted in situ Keratomileusis (Lasik) surgery has been conducted, exhibit pronounced similarity with results obtained from ADDE patients. We also propose a general framework for the transformation of multidimensional images to networks for futuristic biometry. Our approach is general and scalable to other fluctuation-based devices where network parameters derived from fluctuations, act as effective discriminators and diagnostic markers. PMID:26626047

  8. Unobtrusive Biometric System Based on Electroencephalogram Analysis

    NASA Astrophysics Data System (ADS)

    Riera, A.; Soria-Frisch, A.; Caparrini, M.; Grau, C.; Ruffini, G.

    2007-12-01

    Features extracted from electroencephalogram (EEG) recordings have proved to be unique enough between subjects for biometric applications. We show here that biometry based on these recordings offers a novel way to robustly authenticate or identify subjects. In this paper, we present a rapid and unobtrusive authentication method that only uses 2 frontal electrodes referenced to another one placed at the ear lobe. Moreover, the system makes use of a multistage fusion architecture, which demonstrates to improve the system performance. The performance analysis of the system presented in this paper stems from an experiment with 51 subjects and 36 intruders, where an equal error rate (EER) of 3.4% is obtained, that is, true acceptance rate (TAR) of 96.6% and a false acceptance rate (FAR) of 3.4%. The obtained performance measures improve the results of similar systems presented in earlier work.

  9. Robert Heath Lock and His Textbook of Genetics, 1906

    PubMed Central

    Edwards, A. W. F.

    2013-01-01

    Robert Heath Lock (1879–1915), a Cambridge botanist associated with William Bateson and R. C. Punnett, published his book Recent Progress in the Study of Variation, Heredity, and Evolution in 1906. This was a remarkable textbook of genetics for one appearing so early in the Mendelian era. It covered not only Mendelism but evolution, natural selection, biometry, mutation, and cytology. It ran to five editions but was, despite its success, largely forgotten following Lock’s early death in 1915. Nevertheless it was the book that inspired H. J. Muller to do genetics and was remembered by A. H. Sturtevant as the source of the earliest suggestion that linkage might be related to the exchange of parts between homologous chromosomes. Here we also put forward evidence that it had a major influence on the statistician and geneticist R. A. Fisher at the time he was a mathematics student at Cambridge. PMID:23824968

  10. Ultrasound evaluation of cortical brain development in fetuses with intrauterine growth restriction.

    PubMed

    Businelli, Caterina; de Wit, Charlotte; Visser, Gerard H A; Pistorius, Lourens R

    2014-09-10

    Abstract Objective: We evaluated the ultrasound appearance of brain volume and cortical development in fetuses with early growth restriction and placental insufficiency. Methods: We examined a cohort of 20 fetuses with severe intrauterine growth restriction (IUGR) and evidence of placental insufficiency by three-dimensional (3D) ultrasound between 24 and 34 weeks. We graded cortical development and measured the supratentorial intracranial volume. The cortical grading and volume were compared to data obtained from a reference population of 28 adequate for gestational age (AGA) fetuses. Results: Ultrasound examinations were performed in 20 fetuses with IUGR. The biometry and brain volume were significantly reduced in IUGR fetuses. There was evidence of accelerated cortical development in IUGR fetuses. Conclusion: This study confirms that the smaller brain volume in IUGR fetuses, with normal or accelerated cortical maturation as previously depicted with postnatal MRI examination, can be demonstrated by prenatal 3D ultrasound.

  11. Biometry and clinical characteristics of congenital cataracts and microphthalmia in the Miniature Schnauzer.

    PubMed

    Gelatt, K N; Samuelson, D A; Barrie, K P; Das, N D; Wolf, E D; Bauer, J E; Andresen, T L

    1983-07-01

    Forty-two Miniature Schnauzer pups and adults with congenital cataracts and microphthalmia were evaluated by serial ophthalmic examinations, slit lamp biomicroscopic photography, and A-scan ultrasonography. The cataracts were evident when the eyelids opened at 2 weeks, affecting predominantly the lens nucleus and posterior cortex. Lenticonus was evident in 19% of the cataractous lenses. Progression of the cataracts was variable and related to involvement of the equatorial and posterior cortices. Lens-induced uveitis developed in some adult dogs with advanced hypermature cataracts. The globe and lens were smaller than normal in the cataractous eyes, as ascertained by A-scan ultrasonography. Age-matched comparisons of clear lens carrier Miniature Schnauzers and normal Beagles with the cataractous Miniature Schnauzers indicated affected globes and cataractous lenses were reduced 10% to 20% in their anteroposterior lengths. The microphthalmia appeared related to the congenital microphakic cataract.

  12. Description of the process used to create 1992 Hanford Morality Study database

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, E.S.; Buchanan, J.A.; Holter, N.A.

    1992-12-01

    An updated and expanded database for the Hanford Mortality Study has been developed by PNL`s Epidemiology and Biometry Department. The purpose of this report is to document this process. The primary sources of data were the Occupational Health History (OHH) files maintained by the Hanford Environmental Health Foundation (HEHF) and including demographic data and job histories; the Hanford Mortality (HMO) files also maintained by HEHF and including information of deaths of Hanford workers; the Occupational Radiation Exposure (ORE) files maintained by PNL`s Health Physics Department and containing data on external dosimetry; and a file of workers with confirmed internal depositionsmore » of radionuclides also maintained by PNL`s Health Physics Department. This report describes each of these files in detail, and also describes the many edits that were performed to address the consistency and accuracy of data within and between these files.« less

  13. Description of the process used to create 1992 Hanford Morality Study database

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, E. S.; Buchanan, J. A.; Holter, N. A.

    1992-12-01

    An updated and expanded database for the Hanford Mortality Study has been developed by PNL's Epidemiology and Biometry Department. The purpose of this report is to document this process. The primary sources of data were the Occupational Health History (OHH) files maintained by the Hanford Environmental Health Foundation (HEHF) and including demographic data and job histories; the Hanford Mortality (HMO) files also maintained by HEHF and including information of deaths of Hanford workers; the Occupational Radiation Exposure (ORE) files maintained by PNL's Health Physics Department and containing data on external dosimetry; and a file of workers with confirmed internal depositionsmore » of radionuclides also maintained by PNL's Health Physics Department. This report describes each of these files in detail, and also describes the many edits that were performed to address the consistency and accuracy of data within and between these files.« less

  14. [Eyeball shape in children with emmetropia and myopia].

    PubMed

    Dolzhich, G I; Shurygina, I P; Shapovalova, V M

    1991-01-01

    In order to determine the eyeball shape, the authors have carried out ultrasonic biometry of its three major parameters, the anteroposterior axis (APA), horizontal diameter (HD), and vertical diameter (VD), and estimated the ratios of these values (APA/HD and APA/VD) in children with emmetropia (234 eyes) and those with slight and medium-grave myopia (660 eyes), aged 7 to 14. The findings evidence a compressed ellipsoidal shape of the eyeball, presenting as a vertical oval, in all subjects with emmetropic refraction, whatever their age. In myopia the eyeball shape transforms, and all the eyeball sizes are increased, but the APA size is growing more rapidly than the rest sizes, and the eyeball acquires the ball shape with a trend to an elongated ellipsoidal shape. The mean APA length in 7-14-year-old children with emmetropia was up to 23 +/- 0.15 mm, whereas in those with the ball shape of the eyeball it was distended.

  15. Postoperative Refractive Errors Following Pediatric Cataract Extraction with Intraocular Lens Implantation.

    PubMed

    Indaram, Maanasa; VanderVeen, Deborah K

    2018-01-01

    Advances in surgical techniques allow implantation of intraocular lenses (IOL) with cataract extraction, even in young children. However, there are several challenges unique to the pediatric population that result in greater degrees of postoperative refractive error compared to adults. Literature review of the techniques and outcomes of pediatric cataract surgery with IOL implantation. Pediatric cataract surgery is associated with several sources of postoperative refractive error. These include planned refractive error based on age or fellow eye status, loss of accommodation, and unexpected refractive errors due to inaccuracies in biometry technique, use of IOL power formulas based on adult normative values, and late refractive changes due to unpredictable eye growth. Several factors can preclude the achievement of optimal refractive status following pediatric cataract extraction with IOL implantation. There is a need for new technology to reduce postoperative refractive surprises and address refractive adjustment in a growing eye.

  16. Validation of a partial coherence interferometry method for estimating retinal shape

    PubMed Central

    Verkicharla, Pavan K.; Suheimat, Marwan; Pope, James M.; Sepehrband, Farshid; Mathur, Ankit; Schmid, Katrina L.; Atchison, David A.

    2015-01-01

    To validate a simple partial coherence interferometry (PCI) based retinal shape method, estimates of retinal shape were determined in 60 young adults using off-axis PCI, with three stages of modeling using variants of the Le Grand model eye, and magnetic resonance imaging (MRI). Stage 1 and 2 involved a basic model eye without and with surface ray deviation, respectively and Stage 3 used model with individual ocular biometry and ray deviation at surfaces. Considering the theoretical uncertainty of MRI (12-14%), the results of the study indicate good agreement between MRI and all three stages of PCI modeling with <4% and <7% differences in retinal shapes along horizontal and vertical meridians, respectively. Stage 2 and Stage 3 gave slightly different retinal co-ordinates than Stage 1 and we recommend the intermediate Stage 2 as providing a simple and valid method of determining retinal shape from PCI data. PMID:26417496

  17. Validation of a partial coherence interferometry method for estimating retinal shape.

    PubMed

    Verkicharla, Pavan K; Suheimat, Marwan; Pope, James M; Sepehrband, Farshid; Mathur, Ankit; Schmid, Katrina L; Atchison, David A

    2015-09-01

    To validate a simple partial coherence interferometry (PCI) based retinal shape method, estimates of retinal shape were determined in 60 young adults using off-axis PCI, with three stages of modeling using variants of the Le Grand model eye, and magnetic resonance imaging (MRI). Stage 1 and 2 involved a basic model eye without and with surface ray deviation, respectively and Stage 3 used model with individual ocular biometry and ray deviation at surfaces. Considering the theoretical uncertainty of MRI (12-14%), the results of the study indicate good agreement between MRI and all three stages of PCI modeling with <4% and <7% differences in retinal shapes along horizontal and vertical meridians, respectively. Stage 2 and Stage 3 gave slightly different retinal co-ordinates than Stage 1 and we recommend the intermediate Stage 2 as providing a simple and valid method of determining retinal shape from PCI data.

  18. Full ocular biometry through dual-depth whole-eye optical coherence tomography

    PubMed Central

    Kim, Hyung-Jin; Kim, Minji; Hyeon, Min Gyu; Choi, Youngwoon; Kim, Beop-Min

    2018-01-01

    We propose a new method of determining the optical axis (OA), pupillary axis (PA), and visual axis (VA) of the human eye by using dual-depth whole-eye optical coherence tomography (OCT). These axes, as well as the angles “α” between the OA and VA and “κ” between PA and VA, are important in many ophthalmologic applications, especially in refractive surgery. Whole-eye images are reconstructed based on simultaneously acquired images of the anterior segment and retina. The light from a light source is split into two orthogonal polarization components for imaging the anterior segment and retina, respectively. The OA and PA are identified based on their geometric definitions by using the anterior segment image only, while the VA is detected through accurate correlation between the two images. The feasibility of our approach was tested using a model eye and human subjects. PMID:29552378

  19. [Analysis of productivity, quality and cost of first grade laboratories: blood biometry].

    PubMed

    Avila, L; Hernández, P; Cruz, A; Zurita, B; Terres, A M; Cruz, C

    1999-04-01

    Assessment of productivity, quality and production costs and determination of the efficiency of top grade clinical laboratories in Mexico. Ten laboratories were selected from among the total number (52) existing in Mexico City, and the Donabedian model of structure, process and results were applied. Blood count was selected as a tracer. The principal problems found were: inadequate distribution of trained human resources, poor glass material, inadequate analytic process and low productivity. These factors are reflected in the unit costs, which exceed reference laboratory costs by 200%. Only 50% of the laboratories analyzed generate reliable results. Only 20% of the laboratories studied operate efficiently. To solve the problems identified requires integral strategies at different levels. A specific recomendation for the improvement of quality and productivity is an assessment of the cost/benefit of creating a central laboratory and using the remaining sites exclusively for the collection of samples.

  20. Robert Heath Lock and his textbook of genetics, 1906.

    PubMed

    Edwards, A W F

    2013-07-01

    Robert Heath Lock (1879-1915), a Cambridge botanist associated with William Bateson and R. C. Punnett, published his book Recent Progress in the Study of Variation, Heredity, and Evolution in 1906. This was a remarkable textbook of genetics for one appearing so early in the Mendelian era. It covered not only Mendelism but evolution, natural selection, biometry, mutation, and cytology. It ran to five editions but was, despite its success, largely forgotten following Lock's early death in 1915. Nevertheless it was the book that inspired H. J. Muller to do genetics and was remembered by A. H. Sturtevant as the source of the earliest suggestion that linkage might be related to the exchange of parts between homologous chromosomes. Here we also put forward evidence that it had a major influence on the statistician and geneticist R. A. Fisher at the time he was a mathematics student at Cambridge.

  1. Real-Time Detection and Measurement of Eye Features from Color Images

    PubMed Central

    Borza, Diana; Darabant, Adrian Sergiu; Danescu, Radu

    2016-01-01

    The accurate extraction and measurement of eye features is crucial to a variety of domains, including human-computer interaction, biometry, and medical research. This paper presents a fast and accurate method for extracting multiple features around the eyes: the center of the pupil, the iris radius, and the external shape of the eye. These features are extracted using a multistage algorithm. On the first stage the pupil center is localized using a fast circular symmetry detector and the iris radius is computed using radial gradient projections, and on the second stage the external shape of the eye (of the eyelids) is determined through a Monte Carlo sampling framework based on both color and shape information. Extensive experiments performed on a different dataset demonstrate the effectiveness of our approach. In addition, this work provides eye annotation data for a publicly-available database. PMID:27438838

  2. Consumer Health Informatics in the Context of Engaged Citizens and eHealth Services - A New CHI Meta Model.

    PubMed

    Wiesner, Martin; Griebel, Lena; Becker, Kurt; Pobiruchin, Monika

    2016-01-01

    Consumer Health Informatics (CHI) is a relatively new and interdisciplinary field in Medical Informatics. It focuses on consumer- rather than professional-centered services. However, the definitions and understanding of a) what is a "consumer"? or b) what is health technology in the context of CHI? and c) what factors and actors influence the usage of eHealth services? vary widely. The CHI special interest group (SIG) - associated with the German Association for Medical Informatics, Biometry and Epidemiology - conducted two workshops in 2015 to improve the common understanding on these topics. The workshop outcomes, the derived CHI-specific meta model and examples how to apply this model are presented in this paper. The model supports the definition of multi-actor contexts, as it not solely reflects the conventional patient-physician relationship but also allows for the description of second health market providers.

  3. Prenatal Exposure to NO2 and Ultrasound Measures of Fetal Growth in the Spanish INMA Cohort

    PubMed Central

    Iñiguez, Carmen; Esplugues, Ana; Sunyer, Jordi; Basterrechea, Mikel; Fernández-Somoano, Ana; Costa, Olga; Estarlich, Marisa; Aguilera, Inmaculada; Lertxundi, Aitana; Tardón, Adonina; Guxens, Mònica; Murcia, Mario; Lopez-Espinosa, Maria-Jose; Ballester, Ferran

    2015-01-01

    Background Air pollution exposure during pregnancy has been associated with impaired fetal growth. However, few studies have measured fetal biometry longitudinally, remaining unclear as to whether there are windows of special vulnerability. Objective The aim was to investigate the impact of nitrogen dioxide (NO2) exposure on fetal and neonatal biometry in the Spanish INMA study. Methods Biparietal diameter (BPD), femur length (FL), abdominal circumference (AC), and estimated fetal weight (EFW) were evaluated for up to 2,478 fetuses in each trimester of pregnancy. Size at 12, 20, and 34 weeks of gestation and growth between these points, as well as anthropometry at birth, were assessed by SD scores derived using cohort-specific growth curves. Temporally adjusted land-use regression was used to estimate exposure to NO2 at home addresses for up to 2,415 fetuses. Associations were investigated by linear regression in each cohort and subsequent meta-analysis. Results A 10-μg/m3 increase in average exposure to NO2 during weeks 0–12 was associated with reduced growth at weeks 0–12 in AC (–2.1%; 95% CI: –3.7, –0.6) and EFW (–1.6%; 95% CI: –3.0, –0.3). The same exposure was inversely associated with reduced growth at weeks 20–34 in BPD (–2.6%; 95% CI: –3.9, –1.2), AC (–1.8%; 95% CI: –3.3, –0.2), and EFW (–2.1%; 95% CI: –3.7, –0.2). A less consistent pattern of association was observed for FL. The negative association of this exposure with BPD and EFW was significantly stronger in smoking versus nonsmoking mothers. Conclusions Maternal exposure to NO2 in early pregnancy was associated with reduced fetal growth based on ultrasound measures of growth during pregnancy and measures of size at birth. Citation Iñiguez C, Esplugues A, Sunyer J, Basterrechea M, Fernández-Somoano A, Costa O, Estarlich M, Aguilera I, Lertxundi A, Tardón A, Guxens M, Murcia M, Lopez-Espinosa MJ, Ballester F, on behalf of the INMA Project. 2016. Prenatal exposure to NO2 and ultrasound measures of fetal growth in the Spanish INMA Cohort. Environ Health Perspect 124:235–242; http://dx.doi.org/10.1289/ehp.1409423 PMID:26115483

  4. Ocular refractive and biometric characteristics in patients with thalassaemia major.

    PubMed

    Nowroozzadeh, Mohammad Hosein; Kalantari, Zahra; Namvar, Khadije; Meshkibaf, Mohammad Hassan

    2011-07-01

    Thalassaemia major is associated with characteristic findings in craniofacial bony structures and thereby may render abnormal bony orbit and subsequently distinctive ocular biometry. The purpose of the present study was to evaluate the ocular refractive and biometric characteristics in patients with thalassaemia major. This case-controlled study comprised 94 eyes of 47 patients with thalassaemia major and 88 eyes of 44 age- and sex-matched healthy control subjects. All participants had a complete ocular examination including slitlamp biomicroscopy, fundoscopy, ocular biometry, keratometry, refraction and analysis using Fourier transformation. There were no significant differences in spherical equivalent (p = 0.66) and total astigmatism (p = 0.83) between groups. Mean uncorrected vision and visual acuities (logMar) were similar (p = 0.32 and p = 0.71, respectively). Compared with controls, thalassaemic patients had a shorter axial length (23.01 ± 0.12 [SEM] mm versus 23.46 ± 0.12 mm, p = 0.035), thicker crystalline lens (4.01 ± 0.11 mm versus 3.87 ± 0.1 mm, p = 0.046) and steeper average keratometry (44.02 ± 0.24 D versus 43.44 ± 0.24, p = 0.03). Fifty-seven per cent of thalassaemic patients had against-the-rule astigmatism (total), while 64.6 per cent of controls showed a with-the-rule pattern (p < 0.05). These patterns were also found for corneal astigmatism. The magnitudes of total, corneal and lenticular astigmatism were similar among groups. Regression analysis showed significant correlation between corneal (J0 and J45) and total (J0 and J45) astigmatism. The correlations were less prominent between lenticular and total J0 and J45. The mean intraocular pressure was 14.68 ± 0.27 mmHg and 13.3 ± 0.26 mmHg in the thalassaemia and control groups, respectively (p < 0.001). Six eyes (12.8 per cent) of four patients in the thalassaemia group had posterior subcapsular cataract, while the condition had not been observed in controls (p = 0.049). Shorter axial length, thicker lens, steeper corneal curvature and more against-the-rule pattern were characteristic findings in patients with thalassaemia major. © 2011 The Authors. Clinical and Experimental Optometry © 2011 Optometrists Association Australia.

  5. Significant Axial Elongation with Minimal Change in Refraction in 3- to 6-Year-Old Chinese Preschoolers: The Shenzhen Kindergarten Eye Study.

    PubMed

    Guo, Xinxing; Fu, Min; Ding, Xiaohu; Morgan, Ian G; Zeng, Yangfa; He, Mingguang

    2017-12-01

    To document the distribution of ocular biometry and to evaluate its associations with refraction in a group of Chinese preschoolers. Population-based cross-sectional study. A total of 1133 preschoolers 3 to 6 years of age from 8 representative kindergartens. Biometric measurements including axial length (AL), anterior chamber depth (ACD), and corneal radius of curvature (CR) were obtained from partial-coherence laser interferometry (IOL Master; Carl Zeiss Meditec, Oberkochen, Germany) before cycloplegia. Lens power (LP) and AL-to-CR ratio were calculated. Cycloplegic refraction (3 drops of 1% cyclopentolate) was measured using an autorefractor (KR8800; Topcon Corp., Tokyo, Japan), and spherical equivalent refraction (SER) was calculated. Biometric and refractive parameters were assessed as a function of age and gender. Multiple regression analysis was performed to explore the associations between refraction and ocular biometry. Ocular biometric distributions and their relationships to refraction. Among the 1127 children (99.5%) with successful cycloplegic refraction, mean SER was 1.37±0.63 diopters (D). Prevalence of myopia increased from 0% at 3 years of age to 3.7% (95% confidence interval, 1.0%-6.5%) at 6 years of age. Biometric parameters followed Gaussian distributions with means of 22.39±0.68 mm for AL, 7.79±0.25 mm for CR, and 24.61±1.42 D for calculated LP; and non-Gaussian distributions with means of 3.34±0.24 mm for ACD and 2.88±0.06 for AL-to-CR ratio. Axial length, ACD, and AL-to-CR ratio increased from 3 to 6 years of age, CR remained stable, whereas LP declined. Overall, SER declined slightly. For the SER variance, AL explained 18.6% and AL-to-CR ratio explained 39.8%, whereas AL, CR, and LP accounted for 80.0% after adjusting for age and gender. Young Chinese children are predominantly mildly hyperopic, with a low prevalence of myopia by the age of 6 years. An increase of 1 mm in AL was associated with only 0.45 D of myopic change. Decreases in LP reduce the myopic shifts that normally would be associated with increases in AL, and thus play a key role in refractive development in this age group. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Multivariable analysis of tests for the diagnosis of intrauterine growth restriction.

    PubMed

    Bachmann, L M; Khan, K S; Ogah, J; Owen, P

    2003-04-01

    To describe how data from antenatal fetal ultrasound biometry, amniotic fluid index and umbilical artery Doppler can be appropriately combined using multivariable models and to investigate how the addition of these ultrasound parameters influences the ability to predict intrauterine growth restriction (IUGR). This was a prospective cohort study involving 274 low-risk pregnancies undergoing serial ultrasound examination at predetermined intervals. Standard deviation (Z) scores of the last values for fetal abdominal area (FAA), growth velocity of the FAA, amniotic fluid index (AFI) and umbilical artery Doppler pulsatility index prior to delivery were calculated for 260 fetuses. Customized estimated fetal weight (cEFW) centiles were also calculated using the last EFW before delivery after adjustment for fetal gender, gestational age, birth order and maternal weight, height and ethnic origin. Following delivery the neonatal ponderal index was calculated and centile position obtained. A neonatal ponderal index <25(th) centile served as the main outcome measure for diagnosis of IUGR. Logistic regression analysis was used to delineate the predictive value of the three fetal growth tests FAA, FAA growth velocity and cEFW and the additional values of AFI and pulsatility index of the umbilical artery. The areas under the receiver-operating characteristics (ROC) curves (95% confidence interval) for FAA, FAA growth velocity and cEFW alone were 0.819 (0.748-0.891), 0.784 (0.699-0.869) and 0.74 (0.643-0.837), respectively, in the prediction of a neonatal ponderal index <25(th) centile. The addition of both the AFI and pulsatility index to FAA, FAA growth velocity and cEFW generated small increases in the areas, to 0.831 (0.758-0.904), 0.817 (0.735-0.899) and 0.766 (0.672-0.859), respectively. These improvements in diagnostic prediction were not statistically significant. The addition of AFI and umbilical artery pulsatility index to the fetal biometry parameters did not significantly increase the ROC areas in the study population. The approach applied in this study is useful in the context of hypothesis generation. Further studies using larger data sets and other predictors should be carried out using the analytical techniques outlined in this paper to determine the contribution of various antenatal tests in the prediction of IUGR. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

  7. Impact on obstetric outcome of third-trimester screening for small-for-gestational-age fetuses.

    PubMed

    Callec, R; Lamy, C; Perdriolle-Galet, E; Patte, C; Heude, B; Morel, O

    2015-08-01

    To evaluate the performance of screening for small-for-gestational-age (SGA) fetuses by ultrasound biometry at 30-35 weeks' gestation, and to determine the impact of screening on obstetric and neonatal outcomes. For this prospective cohort study, pregnant women were recruited from two French university maternity centers between 2003 and 2006. Performance measures of third-trimester biometry for the prediction of SGA, defined as estimated fetal weight < 10(th) centile, were analyzed. Obstetric outcomes and neonatal health status were compared, first, between SGA neonates diagnosed correctly at ultrasound examination (true positive (TP); n = 45) and SGA neonates that went undiagnosed (false negative (FN); n = 110) and, second, between non-SGA neonates identified as normal at ultrasound examination (true negative (TN); n = 1641) and non-SGA neonates diagnosed incorrectly as SGA (false positive (FP); n = 101). In the prediction of SGA, third-trimester ultrasound had a sensitivity of 29.0% (95% CI, 22.5-36.6%) and specificity of 94.2% (95% CI, 93.0-95.2%). Positive and negative predictive values were 30.8% (95% CI, 23.9-38.7%) and 93.7% (95% CI, 92.5-94.8%), respectively. One hundred and ten SGA neonates went undiagnosed at ultrasound. Compared to the TN neonates considered as of normal weight at ultrasound, planned preterm delivery (before 37 weeks) and elective Cesarean section for a fetal growth indication were 2.4 (P = 0.01) and 2.85 (P = 0.003) times more likely to occur, respectively, in the FP group of non-SGA neonates, diagnosed incorrectly as SGA during the antenatal period. There was no statistically significant difference in 5-min Apgar score < 7, cord blood pH at birth < 7.15 and need for neonatal resuscitation between the two subgroups (TN vs FP and TP vs FN). The performance of third-trimester ultrasound screening for SGA seems poor, as it misses the diagnosis of a large number of SGA neonates. The consequences of routine screening for SGA in a low-risk population may lead to unnecessary planned preterm deliveries and elective Cesarean sections in FP pregnancies, without improved neonatal outcome in the FN pregnancies. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  8. The occurrence of Clithon retropictus (v. Martens, 1879) (Gastropoda: Neritidae) in an unusual habitat, northern Jeju Island, Republic of Korea

    NASA Astrophysics Data System (ADS)

    Noseworthy, Ronald G.; Lee, Hee-Jung; Choi, Kwang-Sik

    2013-09-01

    Clithon retropictus is a neritid gastropod inhabiting mainly brackish water. Currently this species has been listed as a second grade endangered species of wildlife in Korea by the Ministry of Environment, due to the decrease in its population size. C. retropictus has previously been identified from estuaries on the south coast of Korea. In Jeju Island, this species has been reported only from the south coast. However, a population has recently been discovered on the north coast of the island in an apparently new type of habitat, under rocks adjacent to a dry riverbed on a muddy substrate. C. retropictus was found to be aggregated under some of the larger rocks, and the habitat was located near the high tide line. The present study reports some possible reasons for the occurrence of the population in this unusual habitat, and provides useful information on the biometry and population size which can be used in the management of this endangered species.

  9. Impact of nuclear cataract density on postoperative refractive outcome: IOL Master versus ultrasound.

    PubMed

    Ueda, Tetsuo; Taketani, Futoshi; Ota, Takeo; Hara, Yoshiaki

    2007-01-01

    To evaluate the effect of cataract density on the postoperative refractive outcome. For 59 nuclear cataract eyes, the axial length was preoperatively measured by the IOL Master (Zeiss, Germany) and ultrasound (US; UD-6000, Tomey, Japan) and the cataract density by EAS-1000 (Nidek, Japan). The prediction error was used as evaluation of the accuracy of ocular biometry. There were significant differences between IOL Master and US in the mean error (0.24 +/- 0.63 vs. 0.69 +/- 0.64 dpt, p < 0.001) and the mean absolute error (0.57 +/- 0.36 vs. 0.79 +/- 0.53 dpt, p < 0.001). The cataract density was significantly correlated with the prediction error with IOL Master (r = 0.24, p = 0.03) and US (r = 0.29, p = 0.01). Measurements with the IOL Master are slightly affected by the cataract density due to the refractive index change, but its accuracy is less affected than US. (c) 2007 S. Karger AG, Basel.

  10. Before hierarchy: the rise and fall of Stephen Jay Gould's first macroevolutionary synthesis.

    PubMed

    Dresow, Max W

    2017-06-01

    Few of Stephen Jay Gould's accomplishments in evolutionary biology have received more attention than his hierarchical theory of evolution, which postulates a causal discontinuity between micro- and macroevolutionary events. But Gould's hierarchical theory was his second attempt to supply a theoretical framework for macroevolutionary studies-and one he did not inaugurate until the mid-1970s. In this paper, I examine Gould's first attempt: a proposed fusion of theoretical morphology, multivariate biometry and the experimental study of adaptation in fossils. This early "macroevolutionary synthesis" was predicated on the notion that parallelism and convergence dominate the history of higher taxa, and moreover, that they can be explained in terms of adaptation leading to mechanical improvement. In this paper, I explore the origins and contents of Gould's first macroevolutionary synthesis, as well as the reasons for its downfall. In addition, I consider how various developments during the mid-1970s led Gould to identify hierarchy and constraint as the leading themes of macroevolutionary studies-and adaptation as a macroevolutionary red herring.

  11. [Apple-Macintosh compatible software for documentation, management and evaluation of ultrasound findings in obstetrics].

    PubMed

    Kurmanavicius, J; Huch, R; Huch, A

    1993-02-01

    The advantage of using a computer to automate routine calculations and print out charts of the obstetrical ultrasound examination is obvious. This report describes a software designed to simplify the documentation and analysis of ultrasound data in obstetrics. The system is easy to use, even for persons with little computer knowledge. The programme was written in FoxBase+/Mac (Fox Software, Inc., USA). FoxBase+/Mac takes full advantage of the easy-to-learn, easy-to-use Macintosh interface and is also very fast. Another advantage of this software is that it can be used in teaching. Non-experienced examinators can double-check the correctness of their scanning planes by observing the ultrasound pictures with the markers indicating the right measurement sites and the lists of standard values of biometrical parameters for the corresponding gestational age on the screen. In routine obstetrical ultrasound examinations it takes less than 5 min to enter the foetal biometry data and print out reports. These reports are informative and easy to interpret.

  12. Twins Eye Study in Tasmania (TEST): Rationale and Methodology to Recruit and Examine Twins

    PubMed Central

    Mackey, David A; MacKinnon, Jane R; Brown, Shayne A; Kearns, Lisa S; Ruddle, Jonathan B; Sanfilippo, Paul G; Sun, Cong; Hammond, Christopher J; Young, Terri L; Martin, Nicholas G; Hewitt, Alex W

    2013-01-01

    Visual impairment is a leading cause for morbidity and poor quality of life in our community. Unravelling the mechanisms underpinning important blinding diseases could allow for preventative or curative steps to be implemented. Twin siblings provide a unique opportunity in biology to discover genes associated with numerous eye diseases and ocular biometry. Twins are particularly useful for quantitative trait analysis through genome-wide association and linkage studies. Although many studies involving twins rely on twin registries, we present our approach to the Twins Eye Study in Tasmania to provide insight into possible recruitment strategies, expected participation rates and potential examination strategies that can be considered by other researchers for similar studies. Five separate avenues for cohort recruitment were adopted: 1) piggy-backing existing studies where twins had been recruited; 2); utilising the national twin registry; 3) word of mouth and local media publicity; 4) directly approaching schools; and finally 5) collaborating with other research groups studying twins. PMID:19803772

  13. Nonimaging applications for microbolometer arrays

    NASA Astrophysics Data System (ADS)

    Picard, Francis; Jerominek, Hubert; Pope, Timothy D.; Zhang, Rose; Ngo, Linh P.; Tremblay, Bruno; Tasker, Nick; Grenier, Carol; Bilodeau, Ghislain; Cayer, Felix; Lehoux, Mario; Alain, Christine; Larouche, Carl; Savard, Simon

    2001-10-01

    In an effort to leverage uncooled microbolometer technology, testing of bolometer performance in various nonimaging applications has been performed. One of these applications makes use of an uncooled microbolometer array as the sensing element for a laser beam analyzer. Results of the characterization of cw CO2 laser beams with this analyzer are given. A comparison with the results obtained with a commercial laser beam analyzer is made. Various advantages specific to microbolometer arrays for this application are identified. A second application makes use of microbolometers for absolute temperature measurements. The experimental method and results are described. The technique's limitations and possible implementations are discussed. Finally, the third application evaluated is related to the rapidly expanding field of biometry. It consists of using a modified microbolometer array for fingerprint sensing. The basic approach allowing the use of microbolometers for such an application is discussed. The results of a proof-of-principle experiment are described. Globally, the described work illustrates the fact that microbolometer array fabrication technology can be exploited for many important applications other than IR imaging.

  14. Anterior Eye Imaging with Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  15. [Influence of trigeminal nerve lesion on facial growth: study of two cases of Goldenhar syndrome].

    PubMed

    Darris, Pierre; Treil, Jacques; Marchal-Sixou, Christine; Baron, Pascal

    2015-06-01

    This cases report confirms the hypothesis that embryonic and maxillofacial growth are influenced by the peripheral nervous system, including the trigeminal nerve (V). So, it's interesting to use the stigma of the trigeminal nerve as landmarks to analyze the maxillofacial volume and understand its growth. The aim of this study is to evaluate the validity of the three-dimensional cephalometric analysis of Treil based on trigeminal landmarks. The first case is a caucasian female child with Goldenhar syndrome. The second case is a caucasian male adult affected by the same syndrome. In both cases, brain MRI showed an unilateral trigeminal nerve lesion, ipsilateral to the facial dysmorphia. The results of this radiological study tend to prove the primary role of the trigeminal nerve in craniofacial growth. These cases demonstrate the validity of the theory of Moss. They are one of anatomo-functional justifications of the three-dimensional cephalometric biometry of Treil based on trigeminal nerve landmarks. © EDP Sciences, SFODF, 2015.

  16. Laser speckle decorrelation for fingerprint acquisition

    NASA Astrophysics Data System (ADS)

    Schirripa Spagnolo, Giuseppe; Cozzella, Lorenzo

    2012-09-01

    Biometry is gaining popularity as a physical security approach in situations where a high level of security is necessary. Currently, biometric solutions are embedded in a very large and heterogeneous group of applications. One of the most sensible is for airport security access to boarding gates. More airports are introducing biometric solutions based on face, fingerprint or iris recognition for passenger identification. In particular, fingerprints are the most widely used biometric, and they are mandatorily included in electronic identification documents. One important issue, which is difficult to address in traditional fingerprint acquisition systems, is preventing contact between subsequent users; sebum, which can be a potential vector for contagious diseases. Currently, non-contact devices are used to overcome this problem. In this paper, a new contact device based on laser speckle decorrelation is presented. Our system has the advantage of being compact and low-cost compared with an actual contactless system, allowing enhancement of the sebum pattern imaging contrast in a simple and low-cost way. Furthermore, it avoids the spreading of contagious diseases.

  17. Haldane's The causes of evolution and the Modern Synthesis in evolutionary biology.

    PubMed

    Sarkar, Sahotra

    2017-11-01

    This paper argues that Haldane's The causes of evolution was the most important founding document in the emergence of the received view of evolutionary theory which is typically referred to as the Modern Synthesis. Whether or not this historical development is characterized as a synthesis (which remains controversial), this paper argues the most important component of the emergence of the received view consisted of showing how the formal rules of Mendelian inheritance are based on (or emerge from) the material basis of heredity established by classical genetics primarily through the experimental work on Drosophila genetics of the Morgan school in the 1910s and 1920s. This is one of the most important achievements of Haldane's book. Thus this paper rejects both (i) the view that the synthesis was a unification of biometry and Mendelism and (ii) the claim that it arose from work primarily done in the late 1930s and 1940s by naturalists rather than theoretical population and classical experimental geneticists.

  18. In vivo biometry in the mouse eye with low coherence interferometry.

    PubMed

    Schmucker, Christine; Schaeffel, Frank

    2004-01-01

    A major drawback of the mouse model of myopia is that the ocular dimensions cannot be measured in vivo, and that histological techniques post-mortem suffer from limited resolution. We have tested the potential of a newly developed technique, optical low coherence interferometry (OLCI), adapted for short measurement distances by Meditec, Carl Zeiss, Jena, Germany (the "ACMaster"). Using this technique, ocular biometry was performed in mice with normal vision and after deprivation of form vision. Axial eye length, corneal thickness and anterior chamber depth were measured in 23 mice, aged 25-53 days, and standard deviations from repeated measurements in the same eyes, as well as intra-individual and inter-individual variability were determined in different age groups. The data were compared to those from a preceding study in which biometrical data were obtained from frozen sections [Vision Res. 44 (2004) 1857]. Refractions were measured by automated infrared photorefraction. Mice had either normal visual exposure or were monocularly deprived of form vision for 14 days. Using OLCI, axial length could be determined with an average standard deviation of 8.0 +/- 2.9 microm, corneal thickness with 3.5 +/- 2.1 microm, and anterior chamber depth with 10.6 +/- 12.3 microm. Neither axial length, nor corneal thickness, nor anterior chamber depth were significantly different in left and right eyes of individual mice that had normal visual experience (mean absolute difference between axial lengths: 17 +/- 18 microm, between corneal thickness 5.1 +/- 4.8 microm, and between anterior chamber depths 16.7 +/- 14.8 microm). Compared to the variability that was previously found in frozen sections, the variability of axial length measurements with OLCI was 2.7 times less. After two weeks of form deprivation, OLCI revealed a significant axial elongation in the occluded eyes, compared to the contralateral fellow eyes (+38 +/- 36 microm or 1.16%, p = 0.045, n = 7, paired t-test). In this sample, no accompanying myopic shift was observed in the occluded eyes but this observation is not unexpected given the inherently variable responses of mouse eye growth to visual deprivation. OLCI had sufficient resolution in living mice to detect axial length changes in vivo that were equivalent to a dioptric change of 2 D. Using this technique, it was confirmed that mouse eyes respond to form deprivation by axial elongation, similar to the eyes of other animal models. The lack of a myopic shift in this sample, despite the axial elongation, demonstrates that biometric data are particularly important when the mouse eye is used as a model to study myopia.

  19. Biometry of the hypospadic penis after hormone therapy (testosterone and estrogen): A randomized, double-blind controlled trial.

    PubMed

    Paiva, Kelly Christina de Castro; Bastos, André Netto; Miana, Laura Pimenta; Barros, Eveline de Souza; Ramos, Plínio Santos; Miranda, Lara Meneguelli; Faria, Natália Maia; Avarese de Figueiredo, André; de Bessa, José; Netto, José Murillo B

    2016-08-01

    The use of preoperative hormonal stimulation before hypospadias surgery aims to increase penile size and achieve better surgical results; however, the rules are not clear in the literature. We evaluated the effects of topical testosterone and estrogen in the hypospadic penis regarding biometric measures, side effects, and serum hormonal levels. To our knowledge, this is the first study using estradiol prior to hypospadias surgery. Sixty-nine children with hypospadias were randomly divided into three study groups: a control group (CG) of 17 children given placebo cream; a testosterone group (TG) of 28 children who used 1% testosterone propionate; and an estradiol group (EG) of 24 children using 0.01% estradiol. All subjects applied the topical ointment on the entire penis, twice daily for 30 days before surgical correction. Biometric evaluation of the penis included penile length and diameter, glans diameter, distance from the urethral meatus to the tip, and the width of the urethral plate. These measurements as well as serum hormone level, and side effects were evaluated prior to hormone use, and 30 and 90 days after. After 30 days an increase in penile diameter and length and diameter of the glans were observed in TG (p < 0.05). The width of the urethral plate and distance from meatus to the tip increased in TG, although not significantly. The most frequent side effects were appearance of pubic hair and darkening of the genital skin, mainly in TG, but these were transient and disappeared after 90 days of treatment. No significant variations were seen in serum hormonal levels (Table). As in previous studies, an increase in penile length and diameter, and glans diameter was observed with the use of testosterone. Proximal urethral plate width and distance from the meatus to the tip of the penis had a tendency to increase also in TG. Estradiol did not change biometric measure of the penis. Few side effects occurred after both hormones, and any that did improved after 90 days follow-up and did not change hormone serum levels. Preoperative use of topical testosterone increases penile size, diameter of the penis and glans. The use of estradiol does not change penile biometry. Side effects occur mainly with the use of testosterone and are transient. No significant and persistent hormonal changes were observed. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  20. Progress in computer vision.

    NASA Astrophysics Data System (ADS)

    Jain, A. K.; Dorai, C.

    Computer vision has emerged as a challenging and important area of research, both as an engineering and a scientific discipline. The growing importance of computer vision is evident from the fact that it was identified as one of the "Grand Challenges" and also from its prominent role in the National Information Infrastructure. While the design of a general-purpose vision system continues to be elusive machine vision systems are being used successfully in specific application elusive, machine vision systems are being used successfully in specific application domains. Building a practical vision system requires a careful selection of appropriate sensors, extraction and integration of information from available cues in the sensed data, and evaluation of system robustness and performance. The authors discuss and demonstrate advantages of (1) multi-sensor fusion, (2) combination of features and classifiers, (3) integration of visual modules, and (IV) admissibility and goal-directed evaluation of vision algorithms. The requirements of several prominent real world applications such as biometry, document image analysis, image and video database retrieval, and automatic object model construction offer exciting problems and new opportunities to design and evaluate vision algorithms.

  1. Intraocular Pressure, Tear Production, and Ocular Echobiometry in Guinea Pigs (Cavia porcellus)

    PubMed Central

    Rajaei, Seyed Mehdi; Mood, Maneli Ansari; Sadjadi, Reza; Azizi, Farzaneh

    2016-01-01

    The purpose of this study was to evaluate intraocular pressure (IOP) by means of rebound tonometry, to assess tear production by using the endodontic absorbent paper point tear test (EAPTT) and phenol red thread test (PRTT), and to determine the effects of time of day on IOP and tear production in guinea pigs. The study population comprised 24 healthy adult guinea pigs (12 male, 12 female; 48 eyes) of different breeds and ranging in age from 12 to 15 mo. IOP and tear production were measured at 3 time points (0700, 1500, and 2300) during a 24-h period. Overall values (mean ± 1 SD) were: IOP, 6.81 ± 1.41 mm Hg (range, 4.83 to 8.50); PRTT, 14.33 ± 1.35 mm (range, 12.50 to 16.83); and EAPTT, 8.54 ± 1.08 mm (range, 7.17 to 10.0 mm). In addition, ultrasound biometry was performed by using a B-mode system with linear 8-MHz transducer. This study reports reference values for IOP and tear production in guinea pigs. PMID:27423156

  2. Normative biometrics for fetal ocular growth using volumetric MRI reconstruction.

    PubMed

    Velasco-Annis, Clemente; Gholipour, Ali; Afacan, Onur; Prabhu, Sanjay P; Estroff, Judy A; Warfield, Simon K

    2015-04-01

    To determine normative ranges for fetal ocular biometrics between 19 and 38 weeks gestational age (GA) using volumetric MRI reconstruction. The 3D images of 114 healthy fetuses between 19 and 38 weeks GA were created using super-resolution volume reconstructions from MRI slice acquisitions. These 3D images were semi-automatically segmented to measure fetal orbit volume, binocular distance (BOD), interocular distance (IOD), and ocular diameter (OD). All biometry correlated with GA (Volume, Pearson's correlation coefficient (CC) = 0.9680; BOD, CC = 0.9552; OD, CC = 0.9445; and IOD, CC = 0.8429), and growth curves were plotted against linear and quadratic growth models. Regression analysis showed quadratic models to best fit BOD, IOD, and OD and a linear model to best fit volume. Orbital volume had the greatest correlation with GA, although BOD and OD also showed strong correlation. The normative data found in this study may be helpful for the detection of congenital fetal anomalies with more consistent measurements than are currently available. © 2015 John Wiley & Sons, Ltd. © 2015 John Wiley & Sons, Ltd.

  3. Use of External Cephalic Version and Amnioreduction in the Delivery of a Fetal Demise with Macrocephaly Secondary to Massive Intracranial Teratoma.

    PubMed

    Blitz, Matthew J; Greeley, Elizabeth; Tam, Hima Tam; Rochelson, Burton

    2015-04-01

    Introduction Congenital intracranial tumors are rare and often incidentally diagnosed on routine ultrasound. We report a case of a fetal demise with a massive intracranial teratoma at 25 weeks of gestation and the management of her delivery in the setting of macrocephaly, breech presentation, and polyhydramnios. Case A 31-year-old G3P1011 woman at 25 weeks' gestation presented with a recent fetal demise and a fetal intracranial tumor first identified at 16 weeks' gestational age. The patient had declined termination of pregnancy. Biometry was consistent with 24 weeks' gestation, except for a head circumference of 394.4 mm consistent with 39 weeks' gestation. The fetus was in a breech presentation. An external cephalic version (ECV) was successfully performed under epidural anesthesia and an amnioreduction was then performed to stabilize the fetal position. Immediate induction of labor and vaginal delivery followed. Discussion ECV and amnioreduction may help facilitate delivery in cases of fetal demise complicated by macrocephaly, malpresentation, and polyhydramnios.

  4. Monola oil versus canola oil as a fish oil replacer in rainbow trout feeds: effects on growth, fatty acid metabolism and final eating quality.

    PubMed

    Turchini, G M; Moretti, V M; Hermon, K; Caprino, F; Busetto, M L; Bellagamba, F; Rankin, T; Keast, R S J; Francis, D S

    2013-11-15

    Monola oil, a high oleic acid canola cultivar, and canola oil were evaluated as replacers of fish oil at three levels of inclusion (60%, 75% and 90%) in rainbow trout diets. After a 27-week grow-out cycle, the diet-induced effects on growth, fatty acid metabolism and final eating quality were assessed. Overall, no effects were noted for growth, feed utilisation or fish biometry, and the fatty acid composition of fish fillets mirrored that of the diets. Dietary treatments affected fillet lipid oxidation (free malondialdehyde), pigmentation and flavour volatile compounds, but only minor effects on sensorial attributes were detected. Ultimately, both oils were demonstrated to possess, to differing extents, suitable qualities to adequately replace fish oil from the perspective of fish performance and final product quality. However, further research is required to alleviate on-going issues associated with the loss of health promoting attributes (n-3 long chain polyunsaturated fatty acids) of final farmed products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Cenozoic Icehouse Forcing Mechanisms on Coccolithophorid Evolution

    NASA Astrophysics Data System (ADS)

    Henderiks, J.

    2007-12-01

    An overall macroevolutionary size decrease in marine unicellular calcifying algae, the coccolithophores, is punctuated by distinct size responses that correlate to major climatic and paleoceanographic events during the Cenozoic. Notably, major size decreases in the ancestors of the modern blooming species Emiliania huxleyi and Gephyrocapsa oceanica are recorded at the Eocene-Oligocene transition (34 Ma) and in the late Miocene (9 Ma). Coccolithophorid cell size (as reconstructed from individual coccolith biometry) is likely influenced by a variety of passive and active evolutionary selection pressures, with specific factors, such as resource availability and climatic change, determining trends in specific intervals of time. This study presents biometric data of the Noelaerhabdacaea, Calcidiscaceae and Coccolithaceae families, which together represent the bulk of coccolith-carbonate buried in Cenozoic deep-sea sediments, from multiple Deep Sea Drilling Project and Ocean Drilling Project sites covering temperate to tropical regions in the Atlantic, Indian and Pacific oceans. Despite distinct regional ecologic responses at each site, striking correspondences within the global data set call for global forcing mechanisms on the size evolution and ecological success of coccolithophores in an 'icehouse' world.

  6. Prediction of small-for-gestational-age neonates: screening by uterine artery Doppler and mean arterial pressure at 19-24 weeks.

    PubMed

    Lesmes, C; Gallo, D M; Saiid, Y; Poon, L C; Nicolaides, K H

    2015-09-01

    To investigate the potential value of uterine artery (UtA) pulsatility index (PI) and mean arterial pressure (MAP) at 19-24 weeks' gestation, in combination with maternal characteristics and medical history and fetal biometry in the prediction of delivery of small-for-gestational-age (SGA) neonates in the absence of pre-eclampsia (PE) and to examine the potential value of such assessment in deciding whether the third-trimester scan should be performed at 32 and/or 36 weeks' gestation. This was a screening study in 63 975 singleton pregnancies, including 3702 (5.8%) that delivered SGA neonates with birth weight < 5(th) percentile (SGA < 5(th) ) in the absence of PE. Multivariable logistic regression analysis was used to determine if screening by a combination of maternal factors, fetal head circumference (HC), abdominal circumference (AC), femur length (FL), UtA-PI and MAP had significant contribution in predicting SGA neonates. A model was developed to select gestational age for the third-trimester assessment, at 32 and/or 36 weeks, based on the results of screening at 19-24 weeks. The detection rates (DRs) of combined screening by maternal factors, fetal biometry and UtA-PI at 19-24 weeks were 90%, 68% and 44% for SGA < 5(th) delivering < 32, 32-36 and ≥ 37 weeks' gestation, respectively, at a false-positive rate (FPR) of 10%. The performance of screening was not improved by the addition of MAP. The DR of SGA < 5(th) delivering at 32-36 weeks improved from 68% to 90% with screening at 32 rather than at 19-24 weeks. Similarly, the DR of SGA < 5(th) delivering ≥ 37 weeks improved from 44% with screening at 19-24 weeks to 59% and 76% when screening at 32 and 36 weeks, respectively. In a hypothetical model, it was estimated that if the desired objective of prenatal screening is to predict about 80% of the cases of SGA < 5(th) , it would be necessary to select 17% of the population at the 19-24-week assessment to be reassessed at 32 weeks and 38% to be reassessed at 36 weeks; 62% would not require a third-trimester scan. Prenatal prediction of a high proportion of SGA neonates necessitates the undertaking of screening in the third trimester of pregnancy in addition to assessment in the second trimester, and the timing of such screening, at 32 and/or 36 weeks, should be contingent on the results of the assessment at 19-24 weeks. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  7. Manipulation of intraocular pressure for studying the effects on accommodation.

    PubMed

    He, Lin; Wendt, Mark; Glasser, Adrian

    2012-09-01

    A reliable experimental system in which IOP can be manipulated or a rapid IOP change can be induced while simultaneously and continuously measuring IOP and the ocular accommodative changes would be useful for understanding the physiological effect of intraocular pressure (IOP) on the accommodative mechanism. In this study, an IOP perfusion and recording system was developed and tested using 13 enucleated pig eyes. The vitreous chamber of the pig eyes was cannulated with a needle connected to two fluid reservoirs at different heights. One reservoir was set to achieve one of three baseline pressures of 5.5 mmHg, 13.0 mmHg and 20.5 mmHg. The other reservoir was moved to achieve pressures of 1.5 mmHg, 3.0 mmHg, 4.5 mmHg and 6.0 mmHg higher than the baseline pressure. The height differential between the reservoirs determined the amplitude of IOP changes. Rapid IOP changes were induced by switching the reservoirs with a solenoid pinch-valve. Two needles, one each attached to a pressure transducer were inserted into the anterior chamber and vitreous chamber respectively. Custom developed software was used to measure the anterior chamber pressure and vitreous chamber pressure at 80 Hz. A high-resolution continuous A-scan ultrasound biometer (CUB) was used to dynamically measure changes in ocular biometry including anterior chamber depth (ACD), lens thickness (LT) and vitreous chamber depth (VCD) while the vitreous chamber pressure was manipulated. The changes in ACD, LT and VCD were analyzed as a function of the pressure change. Perfusion-induced axial biometric changes were quantified by the slopes of linear regression relationships. Both anterior chamber pressure and vitreous chamber pressure changed relatively systematically with the induced vitreous chamber pressure changes (anterior chamber: y = 0.863x + 0.030, r(2) = 0.983; vitreous chamber: y = 0.883x + 0.009, r(2) = 0.981). At perfusion pressures of 5.5, 13.0 and 20.5 mmHg, the slopes for ACD were -5.72, -2.75 and -2.36 μm/mmHg, for LT were -3.31, -1.59 and -1.03 μm/mmHg and for VCD were 19.05, 8.63 and 5.18 μm/mmHg. The system was able to manipulate and monitor IOP while axial biometry changes were recorded. This system will allow the relationship between IOP and accommodation to be studied in non-human primate eyes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Effect of dietary aloe vera on growth and lipid peroxidation indices in rainbow trout (Oncorhynchus mykiss)

    PubMed Central

    Golestan, Ghazale; Salati, Amir Parviz; Keyvanshokooh, Saeed; Zakeri, Mohammad; Moradian, Hossein

    2015-01-01

    Aloe vera has been used worldwide in pharmaceutical, food and cosmetic industries due to the plethora of biological activities of its constituents. This study was done to evaluate the effects of dietary aloe vera on growth and lipid peroxidation in rainbow trout (Oncorhynchus mykiss). A total number of 480 O. mykiss (mean weight 9.50 ± 0.85 g) were randomized into four experimental groups including one control and three experimental groups that aloe vera was incorporated in their diet at 0.5, 1.0 and 2.0 g kg-1. Trial was done for eight weeks. Then biometry and blood sampling were done. Plasma malondialdehyde, ferric reducing ability of plasma and growth index were estimated at the end of study. The results showed that aloe vera extract did not affect growth indices. Malondialdehyde was increased in the experimental group compared to the control group but ferric reducing ability of plasma showed a decrease in experimental groups (p < 0.05) compared to the control group. Our findings showed that dietary aloe vera have adverse effects on antioxidant defense system in O. mykiss. PMID:25992253

  9. Prenatal diagnosis of a de novo 9p terminal chromosomal deletion in a fetus with major congenital anomalies.

    PubMed

    Hou, Wen-Chien; Chen, Chih-Ping; Hwang, Kwei-Shuai; Chen, Ying-Chieh; Lai, Yu-Ju; Tien, Chau-Yang; Su, Her-Young

    2014-12-01

    We describe a prenatal ultrasonography diagnosis of omphalocele and symbrachydactyly in a fetus and review the literature on prenatal diagnosis of 9p terminal chromosomal deletions. A 31-year-old woman (gravida 3, para 1) was referred for genetic counseling because a fetal omphalocele had been detected. Prenatal ultrasonography at 17+ weeks of gestational age revealed a singleton female fetus with biometry equivalent to 18 weeks with an omphalocele. In addition, symbrachydactyly was also noted in the right arm; the wrist bones as well as the metacarpals were missing. A chromosomal study was arranged for a congenital anomaly involving omphalocele. We obtained Giemsa-banded chromosomes from fetal tissue cells, and an abnormal male karyotype with a terminal deletion of the short arm of chromosome 9 at band 9p13 was noted. After delivery, the fetus showed omphalocele, symbrachydactyly, trigonocephaly, sex reversal, a long philtrum, low-set ears, telecanthus, and a frontal prominence. Prenatal diagnosis of abnormal ultrasound findings with omphalocele and symbrachydactyly should include the differential diagnosis of a chromosome 9p deletion. Copyright © 2014. Published by Elsevier B.V.

  10. Birth weight and neonatal adiposity prediction using fractional limb volume obtained with 3D ultrasound.

    PubMed

    O'Connor, Clare; O'Higgins, Amy; Doolan, Anne; Segurado, Ricardo; Stuart, Bernard; Turner, Michael J; Kennelly, Máireád M

    2014-01-01

    The objective of this investigation was to study fetal thigh volume throughout gestation and explore its correlation with birth weight and neonatal body composition. This novel technique may improve birth weight prediction and lead to improved detection rates for fetal growth restriction. Fractional thigh volume (TVol) using 3D ultrasound, fetal biometry and soft tissue thickness were studied longitudinally in 42 mother-infant pairs. The percentages of neonatal body fat, fat mass and fat-free mass were determined using air displacement plethysmography. Correlation and linear regression analyses were performed. Linear regression analysis showed an association between TVol and birth weight. TVol at 33 weeks was also associated with neonatal fat-free mass. There was no correlation between TVol and neonatal fat mass. Abdominal circumference, estimated fetal weight (EFW) and EFW centile showed consistent correlations with birth weight. Thigh volume demonstrated an additional independent contribution to birth weight prediction when added to the EFW centile from the 38-week scan (p = 0.03). Fractional TVol performed at 33 weeks gestation is correlated with birth weight and neonatal lean body mass. This screening test may highlight those at risk of fetal growth restriction or macrosomia.

  11. Five-grass pollen immunotherapy tablet: an update on the latest findings from clinical trials: an interview with Olivier de Beaumont.

    PubMed

    de Beaumont, Olivier; Wilkinson, Jonathan

    2014-01-01

    Interview by Jonathan Wilkinson (Managing Commissioning Editor, Future Science Group). Olivier de Beaumont became Doctor of Medicine at the University of Paris Descartes in 1993. In the same year, he also took a Master of Health Economics degree at Paris Dauphine University. He is also a Master of Business Administration, ESCP Paris, 1999. At Stallergenes, he has been serving as Vice President/Head of Corporate Clinical Development since 2005, responsible for the clinical development plan, clinical operations, biometry and pharmacovigilance. In 2011, he took the responsibility of Senior Vice President Global Medical Affairs responsible for medical information and education, medical communication and nonregistration clinical studies. In 2014 he became Senior Vice President Global Scientific and Medical Affairs. From 2002 to 2005 he led the European business development of the world's leading clinical research organization Quintiles, developing Phase I-IV clinical trial programs for pharmaceutical companies. Previous roles included: Chief Scientific Officer and cofounder of Direct Medica (2000-2002), product champion and lifecycle management at Aventis (1998-2000), medical affairs manager in oncology and respiratory diseases at corporate Rhone-Poulenc Rorer (1993-1998).

  12. Person authentication using brainwaves (EEG) and maximum a posteriori model adaptation.

    PubMed

    Marcel, Sébastien; Millán, José Del R

    2007-04-01

    In this paper, we investigate the use of brain activity for person authentication. It has been shown in previous studies that the brain-wave pattern of every individual is unique and that the electroencephalogram (EEG) can be used for biometric identification. EEG-based biometry is an emerging research topic and we believe that it may open new research directions and applications in the future. However, very little work has been done in this area and was focusing mainly on person identification but not on person authentication. Person authentication aims to accept or to reject a person claiming an identity, i.e., comparing a biometric data to one template, while the goal of person identification is to match the biometric data against all the records in a database. We propose the use of a statistical framework based on Gaussian Mixture Models and Maximum A Posteriori model adaptation, successfully applied to speaker and face authentication, which can deal with only one training session. We perform intensive experimental simulations using several strict train/test protocols to show the potential of our method. We also show that there are some mental tasks that are more appropriate for person authentication than others.

  13. Prenatal Brain MR Imaging: Reference Linear Biometric Centiles between 20 and 24 Gestational Weeks.

    PubMed

    Conte, G; Milani, S; Palumbo, G; Talenti, G; Boito, S; Rustico, M; Triulzi, F; Righini, A; Izzo, G; Doneda, C; Zolin, A; Parazzini, C

    2018-05-01

    Evaluation of biometry is a fundamental step in prenatal brain MR imaging. While different studies have reported reference centiles for MR imaging biometric data of fetuses in the late second and third trimesters of gestation, no one has reported them in fetuses in the early second trimester. We report centiles of normal MR imaging linear biometric data of a large cohort of fetal brains within 24 weeks of gestation. From the data bases of 2 referral centers of fetal medicine, accounting for 3850 examinations, we retrospectively collected 169 prenatal brain MR imaging examinations of singleton pregnancies, between 20 and 24 weeks of gestational age, with normal brain anatomy at MR imaging and normal postnatal neurologic development. To trace the reference centiles, we used the CG-LMS method. Reference biometric centiles for the developing structures of the cerebrum, cerebellum, brain stem, and theca were obtained. The overall interassessor agreement was adequate for all measurements. Reference biometric centiles of the brain structures in fetuses between 20 and 24 weeks of gestational age may be a reliable tool in assessing fetal brain development. © 2018 by American Journal of Neuroradiology.

  14. Fetal growth velocity and body proportion in the assessment of growth.

    PubMed

    Hiersch, Liran; Melamed, Nir

    2018-02-01

    Fetal growth restriction implies failure of a fetus to meet its growth potential and is associated with increased perinatal mortality and morbidity. Therefore, antenatal detection of fetal growth restriction is of major importance in an attempt to deliver improved clinical outcomes. The most commonly used approach towards screening for fetal growth restriction is by means of sonographic fetal weight estimation, to detect fetuses small for gestational age, defined by an estimated fetal weight <10th percentile for gestational age. However, the predictive accuracy of this approach is limited both by suboptimal detection rate (as it may overlook non-small-for-gestational-age growth-restricted fetuses) and by a high false-positive rate (as most small-for-gestational-age fetuses are not growth restricted). Here, we review 2 strategies that may improve the diagnostic accuracy of sonographic fetal biometry for fetal growth restriction. The first strategy involves serial ultrasound evaluations of fetal biometry. The information obtained through these serial assessments can be interpreted using several different approaches including fetal growth velocity, conditional percentiles, projection-based methods, and individualized growth assessment that can be viewed as mathematical techniques to quantify any decrease in estimated fetal weight percentile, a phenomenon that many care providers assess and monitor routinely in a qualitative manner. This strategy appears promising in high-risk pregnancies where it seems to improve the detection of growth-restricted fetuses at increased risk of adverse perinatal outcomes and, at the same time, decrease the risk of falsely diagnosing healthy constitutionally small-for-gestational-age fetuses as growth restricted. Further studies are needed to determine the utility of this strategy in low-risk pregnancies as well as to optimize its performance by determining the optimal timing and interval between exams. The second strategy refers to the use of fetal body proportions to classify fetuses as either symmetric or asymmetric using 1 of several ratios; these include the head circumference to abdominal circumference ratio, transverse cerebellar diameter to abdominal circumference ratio, and femur length to abdominal circumference ratio. Although these ratios are associated with small for gestational age at birth and with adverse perinatal outcomes, their predictive accuracy is too low for clinical practice. Furthermore, these associations become questionable when other, potentially more specific measures such as umbilical artery Doppler are being used. Furthermore, these ratios are of limited use in determining the etiology underlying fetal smallness. It is possible that the use of the 2 gestational-age-independent ratios (transverse cerebellar diameter to abdominal circumference and femur length to abdominal circumference) may have a role in the detection of mild-moderate fetal growth restriction in pregnancies without adequate dating. In addition, despite their limited predictive accuracy, these ratios may become abnormal early in the course of fetal growth restriction and may therefore identify pregnancies that may benefit from closer monitoring of fetal growth. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Effect of primary iris and ciliary body cyst on anterior chamber angle in patients with shallow anterior chamber*

    PubMed Central

    Wang, Bing-hong; Yao, Yu-feng

    2012-01-01

    Objective: To evaluate the prevalence of primary iris and/or ciliary body cysts in eyes with shallow anterior chamber and their effect on the narrowing of the anterior chamber angle. Methods: Among the general physical check-up population, subjects with shallow anterior chambers, as judged by van Herick technique, were recruited for further investigation. Ultrasound biomicroscope (UBM) was used to detect and measure the cysts located in the iris and/or ciliary body, the anterior chamber depth (ACD), the angle opening distance at 500 μm (AOD500), and the trabecular-iris angle (TIA). A-scan ultrasonography was used to measure the ocular biometry, including lens thickness, axial length, lens/axial length factor (LAF), and relative lens position (RLP). The effect of the cyst on narrowing the corresponding anterior chamber angle and the entire angle was evaluated by the UBM images, ocular biometry, and gonioscopic grading. The eye with unilateral cyst was compared with the eye without the cyst for further analysis. Results: Among the 727 subjects with shallow anterior chamber, primary iris and ciliary body cysts were detected in 250 (34.4%) patients; among them 96 (38.4%) patients showed unilateral single cyst, 21 (8.4%) patients had unilateral double cysts, and 42 (16.8%) patients manifested unilateral multiple and multi-quadrants cysts. Plateau iris configuration was found in 140 of 361 (38.8%) eyes with cysts. The mean size of total cysts was (0.6547±0.2319) mm. In evaluation of the effect of the cyst size and location on narrowing the corresponding angle to their position, the proportion of the cysts causing corresponding angle narrowing or closure among the cysts larger than 0.8 mm (113/121, 93.4%) was found to be significantly higher than that of the cysts smaller than 0.8 mm (373/801, 46.6%), and a significant higher proportion was also found in the cysts located at iridociliary sulcus (354/437, 81.0%) than in that at the pars plicata (131/484, 27.1%). In evaluating the effect of the cyst on the entire anterior chamber angle, the eyes with multiple and multi-quadrants cysts manifested significant narrowing of the entire anterior chamber angle as compared with the eyes without cysts, based on the data analysis in comparison of TIA, AOD500, and gonioscopic grading evaluation. The unilateral single or double cysts in the eyes had no significant effect on narrowing of anterior chamber angle as compared with eyes without cysts. The iris and/or ciliary body cysts did not seem to affect the axial length, ACD, lens thickness, RLP, LAF. Conclusions: The prevalence of primary iris and ciliary body cyst was 34.4% in the subjects with shallow anterior chamber. The cysts larger than 0.8 mm, locating at iridociliary sulcus, or multiple and extensive cysts were inclined to cause the angle narrowing or closure. PMID:22949363

  16. Second-trimester amniotic fluid corticotropin-releasing hormone and urocortin in relation to maternal stress and fetal growth in human pregnancy.

    PubMed

    La Marca-Ghaemmaghami, Pearl; Dainese, Sara M; Stalla, Günter; Haller, Marina; Zimmermann, Roland; Ehlert, Ulrike

    2017-05-01

    This study explored the association between the acute psychobiological stress response, chronic social overload and amniotic fluid corticotropin-releasing hormone (CRH) and urocortin (UCN) in 34 healthy, second-trimester pregnant women undergoing amniocentesis. The study further examined the predictive value of second-trimester amniotic fluid CRH and UCN for fetal growth and neonatal birth outcome. The amniocentesis served as a naturalistic stressor, during which maternal state anxiety and salivary cortisol was measured repeatedly and an aliquot of amniotic fluid was collected. The pregnant women additionally completed a questionnaire on chronic social overload. Fetal growth parameters were obtained at amniocentesis using fetal ultrasound biometry and at birth from medical records. The statistical analyzes revealed that the acute maternal psychobiological stress response was unassociated with the amniotic fluid peptides, but that maternal chronic overload and amniotic CRH were positively correlated. Moreover, amniotic CRH was negatively associated with fetal size at amniocentesis and positively with growth in size from amniocentesis to birth. Hardly any studies have previously explored whether acute maternal psychological stress influences fetoplacental CRH or UCN levels significantly. Our findings suggest that (i) chronic, but not acute maternal stress may affect fetoplacental CRH secretion and that (ii) CRH is complexly involved in fetal growth processes as previously shown in animals.

  17. Ocular refractive and biometric characteristics in patients with tilted disc syndrome.

    PubMed

    Dehghani, Cirous; Nowroozzadeh, Mohammad Hosein; Shankar, Sunita; Razeghinejad, Mohammad Reza

    2010-12-01

    Tilted disc syndrome (TDS) is associated with characteristic ocular findings. The purpose of this study was to evaluate the ocular, refractive, and biometric characteristics in patients with TDS. This case-control study included 41 eyes of 25 patients who had established TDS and 40 eyes of 20 healthy control subjects. All participants underwent a complete ocular examination, including refraction and analysis using Fourier transformation, slit lamp biomicroscopy, pachymetry, keratometry, and ocular biometry. Corneal topography examinations were performed in the syndrome group only. There were no significant differences in spherical equivalent (P = 0.13) and total astigmatism (P = 0.37) between groups. However, mean best spectacle-corrected visual acuity (Log Mar) was significantly worse in TDS patients (P = 0.003). The lenticular astigmatism was greater in the syndrome group, whereas the corneal component was greater in controls (P = 0.059 and P = 0.028, respectively). The measured biometric features were the same in both groups, except for the lens thickness and lens-axial length factor, which were greater in the TDS group (P = 0.007 and P = 0.055, respectively). Clinically significant lenticular astigmatism, more oblique corneal astigmatism, and thicker lenses were characteristic findings in patients with TDS. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.

  18. Pediatric cataract: challenges and future directions

    PubMed Central

    Medsinge, Anagha; Nischal, Ken K

    2015-01-01

    Cataract is a significant cause of visual disability in the pediatric population worldwide and can significantly impact the neurobiological development of a child. Early diagnosis and prompt surgical intervention is critical to prevent irreversible amblyopia. Thorough ocular evaluation, including the onset, duration, and morphology of a cataract, is essential to determine the timing for surgical intervention. Detailed assessment of the general health of the child, preferably in conjunction with a pediatrician, is helpful to rule out any associated systemic condition. Although pediatric cataracts have a diverse etiology, with the majority being idiopathic, genetic counseling and molecular testing should be undertaken with the help of a genetic counselor and/or geneticist in cases of hereditary cataracts. Advancement in surgical techniques and methods of optical rehabilitation has substantially improved the functional and anatomic outcomes of pediatric cataract surgeries in recent years. However, the phenomenon of refractive growth and the process of emmetropization have continued to puzzle pediatric ophthalmologists and highlight the need for future prospective studies. Posterior capsule opacification and secondary glaucoma are still the major postoperative complications necessitating long-term surveillance in children undergoing cataract surgery early in life. Successful management of pediatric cataracts depends on individualized care and experienced teamwork. We reviewed the etiology, preoperative evaluation including biometry, choice of intraocular lens, surgical techniques, and recent developments in the field of childhood cataract. PMID:25609909

  19. Morphologic, biometric, and isoenzyme characterization of Trichuris suis.

    PubMed

    Oliveros, R; Cutillas, C; Arias, P; Guevara, D

    1998-06-01

    Trichuris suis isolates were collected from the cecum of Sus scrofa domestica (pig) and S. s. scrofa (wild boar). Morphology and biometry studies were carried out. Morphology studies showed the existence of typical caudal papillae in males of T. suis from wild boars, but no other difference was observed in the biometric parameters (total length, esophageal length, posterior-portion body length, and spicular length) of T. suis isolated from either host. Individual extracts were subjected to malate dehydrogenase (MDH), malic enzyme (ME), glucose 6-phosphate dehydrogenase (G6PD), lactate dehydrogenase (LDH), and superoxide dismutase (SOD) isoenzyme analysis following starch-gel electrophoresis, and the isoenzyme patterns were compared with those obtained from other species of trichurids. MDH, ME, G6PD, LDH, and SOD isoenzyme patterns were identical for T. suis from both hosts. MDH isoenzyme patterns were characterized by the presence of one cathodic isoenzyme. ME, G6PD, and LDH isoenzyme patterns indicated the presence of three phenotypes, whereas the SOD isoenzyme pattern showed only one phenotype characterized by the existence of two (anodic and cathodic) bands. Different LDH and SOD isoenzyme patterns observed for T. suis, T. ovis, and T. skrjabini confirm once more that isoenzyme patterns have potential as a diagnostic tool for differentiation of different species of Trichuris.

  20. Nonhuman Primate Ocular Biometry

    PubMed Central

    Augusteyn, Robert C.; Maceo Heilman, Bianca; Ho, Arthur; Parel, Jean-Marie

    2016-01-01

    Purpose To examine ocular growth in nonhuman primates (NHPs) from measurements on ex vivo eyes. Methods We obtained NHP eyes from animals that had been killed as part of other studies or because of health-related issues. Digital calipers were used to measure the horizontal, vertical, and anteroposterior globe diameters as well as corneal horizontal and vertical diameters of excised globes from 98 hamadryas baboons, 551 cynomolgus monkeys, and 112 rhesus monkeys, at ages ranging from 23 to 360 months. Isolated lens sagittal thickness and equatorial diameter were measured by shadowphotogrammetry. Wet and fixed dry weights were obtained for lenses. Results Nonhuman primate globe growth continues throughout life, slowing toward an asymptotic maximum. The final globe size scales with negative allometry to adult body size. Corneal growth ceases at around 20 months. Lens diameter increases but thickness decreases with increasing age. Nonhuman primate lens wet and dry weight accumulation is monophasic, continuing throughout life toward asymptotic maxima. The dry/wet weight ratio reaches a maximum of 0.33. Conclusions Nonhuman primate ocular globe and lens growth differ in several respects from those in humans. Although age-related losses of lens power and accommodative amplitude are similar, lens growth and properties are different indicating care should be taken in extrapolating NHP observations to the study of human accommodation. PMID:26780314

  1. Prenatal brain MRI of fetuses with Zika virus infection.

    PubMed

    Guillemette-Artur, Prisca; Besnard, Marianne; Eyrolle-Guignot, Dominique; Jouannic, Jean-Marie; Garel, Catherine

    2016-06-01

    An outbreak of Zika virus was observed in French Polynesia in 2013-2014. Maternal Zika virus infection has been associated with fetal microcephaly and severe cerebral damage. To analyze the MRI cerebral findings in fetuses with intrauterine Zika virus infection. We retrospectively analyzed prospectively collected data. Inclusion criteria comprised cases with (1) estimated conception date between June 2013 and May 2014, (2) available US and MRI scans revealing severe fetal brain lesions and (3) positive polymerase chain reaction for Zika virus in the amniotic fluid. We recorded pregnancy history of Zika virus infection and analyzed US and MRI scans. Three out of 12 cases of severe cerebral lesions fulfilled all inclusion criteria. History of maternal Zika virus infection had been documented in two cases. Calcifications and ventriculomegaly were present at US in all cases. MRI showed micrencephaly (n = 3), low cerebellar biometry (n = 2), occipital subependymal pseudocysts (n = 2), polymicrogyria with laminar necrosis and opercular dysplasia (n = 3), absent (n = 1) or hypoplastic (n = 1) corpus callosum and hypoplastic brainstem (n = 1). Severe cerebral damage was observed in our series, with indirect findings suggesting that the germinal matrix is the principal target for Zika virus. The lesions are very similar to severe forms of congenital cytomegalovirus and lymphocytic choriomeningitis virus infections.

  2. 3D digitization methods based on laser excitation and active triangulation: a comparison

    NASA Astrophysics Data System (ADS)

    Aubreton, Olivier; Mériaudeau, Fabrice; Truchetet, Frédéric

    2016-04-01

    3D reconstruction of surfaces is an important topic in computer vision and corresponds to a large field of applications: industrial inspection, reverse engineering, object recognition, biometry, archeology… Because of the large varieties of applications, one can find in the literature a lot of approaches which can be classified into two families: passive and active [1]. Certainly because of their reliability, active approaches, using imaging system with an additional controlled light source, seem to be the most commonly used in the industrial field. In this domain, the 3D digitization approach based on active 3D triangulation has had important developments during the last ten years [2] and seems to be mature today if considering the important number of systems proposed by manufacturers. Unfortunately, the performances of active 3D scanners depend on the optical properties of the surface to digitize. As an example, on Fig 1.a, a 3D shape with a diffuse surface has been digitized with Comet V scanner (Steinbichler). The 3D reconstruction is presented on Fig 1.b. The same experiment was carried out on a similar object (same shape) but presenting a specular surface (Fig 1.c and Fig 1.d) ; it can clearly be observed, that the specularity influences of the performance of the digitization.

  3. [Intra-uterine growth restriction impact on maternal serum concentration of PlGF (placental growth factor): A case control study].

    PubMed

    Margossian, A; Boisson-Gaudin, C; Subtil, F; Rudigoz, R-C; Dubernard, G; Allias, F; Huissoud, C

    2016-01-01

    Placental growth factor (PlGF) is a pro-angiogenic factor mainly assessed in preeclampsia in which its blood concentration is decreased. The aim of this study was to dose the blood concentration of PlGF in women with fetal intra-uterine growth restriction (IUGR) without associated preeclampsia at the time of diagnosis. Case/control study: IUGR was defined by a fetal biometry with abnormal uterine and/or umbilical doppler (n=23). This group was compared to a control group of fetuses (n=25) matched for gestational age at blood sampling for the dosage of maternal seric PlGF. Women with preeclampsia were not included. The plasma PlGF concentration was 11pg/mL (IQR [11-42,8]) in the IUGR group vs 287pg/mL [135-439] in the control group (P<0.001) and this difference was available after adjustment for gestational age at the time of blood sampling (P<0.001). PlGF sensitivity and specificity for discrimination were respectively 87% (CI 95% [66-97]) and 88% (CI 95% [69-97]). Maternal serum PlGF concentrations were very low in IUGR group compared with those of the control group. Copyright © 2015. Published by Elsevier SAS.

  4. "Describing our whole experience": the statistical philosophies of W. F. R. Weldon and Karl Pearson.

    PubMed

    Pence, Charles H

    2011-12-01

    There are two motivations commonly ascribed to historical actors for taking up statistics: to reduce complicated data to a mean value (e.g., Quetelet), and to take account of diversity (e.g., Galton). Different motivations will, it is assumed, lead to different methodological decisions in the practice of the statistical sciences. Karl Pearson and W. F. R. Weldon are generally seen as following directly in Galton's footsteps. I argue for two related theses in light of this standard interpretation, based on a reading of several sources in which Weldon, independently of Pearson, reflects on his own motivations. First, while Pearson does approach statistics from this "Galtonian" perspective, he is, consistent with his positivist philosophy of science, utilizing statistics to simplify the highly variable data of biology. Weldon, on the other hand, is brought to statistics by a rich empiricism and a desire to preserve the diversity of biological data. Secondly, we have here a counterexample to the claim that divergence in motivation will lead to a corresponding separation in methodology. Pearson and Weldon, despite embracing biometry for different reasons, settled on precisely the same set of statistical tools for the investigation of evolution. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Effectiveness and consistency of a suite of descriptors for assessing the ecological status of seagrass meadows (Posidonia oceanica L. Delile)

    NASA Astrophysics Data System (ADS)

    Rotini, Alice; Belmonte, Alessandro; Barrote, Isabel; Micheli, Carla; Peirano, Andrea; Santos, Rui O.; Silva, João; Migliore, Luciana

    2013-09-01

    The increasing rate of human-induced environmental changes on coastal marine ecosystems has created a demand for effective descriptors, in particular for those suitable for monitoring the status of seagrass meadows. Growing evidence has supported the useful application of biochemical and genetic descriptors such as secondary metabolite synthesis, photosynthetic activity and genetic diversity. In the present study, we have investigated the effectiveness of different descriptors (traditional, biochemical and genetic) in monitoring seagrass meadow conservation status. The Posidonia oceanica meadow of Monterosso al Mare (Ligurian sea, NW Mediterranean) was subjected to the measurement of bed density, leaf biometry, total phenols, soluble protein and photosynthetic pigment content as well as to RAPD marker analysis. This suite of descriptors provided evidence of their effectiveness and convenient application as markers of the conservation status of P. oceanica and/or other seagrasses. Biochemical/genetic descriptors and those obtained by traditional methods depicted a well conserved meadow with seasonal variability and, particularly in summer, indicated a healthier condition in a portion of the bed (station C), which was in agreement with the physical and sedimentological features of the station. Our results support the usefulness of introducing biochemical and genetic approaches to seagrass monitoring programs since they are effective indicators of plant physiological stress and environmental disturbance.

  6. Metabolic alterations in broiler chickens experimentally infected with sporulated oocysts of Eimeria maxima.

    PubMed

    Freitas, Fagner Luiz da Costa

    2014-01-01

    Metabolic and morphometric alterations of the duodenal villi caused by parasitism of chickens by Eimeria maxima were evaluated, using 100 male Cobb birds, randomly distributed into two groups (control and infected). The infected group was inoculated with 0.5 ml of a solution containing 5 × 10³ sporulated oocysts of Eimeria maxima. Ten birds per sample were sacrificed on the 6th, 11th, 22nd and 41st days post-infection (dpi). In order to evaluate the alterations, samples of duodenum, jejunum and ileum fragments were collected after necropsy for histological analysis. Villus biometry was determined by means of a slide graduated in microns that was attached to a binocular microscope. To evaluate the biochemical data, 5 ml of blood were sampled from the birds before sacrifice. The statistical analyses were performed using the GraphPad 5 statistical software for Windows. Tukey's multiple comparison test (p <0.05) was performed for the different dpi's and the unpaired t test for the difference between the groups. Infection by E. maxima causes both qualitative and quantitative alterations to the structure of the intestinal villi, thereby interfering with the absorption of nutrients such as calcium, phosphorus, magnesium, protein and lipids, with consequent reductions in the birds' weights.

  7. Hylemetry versus Biometry: a new method to certificate the lithography authenticity

    NASA Astrophysics Data System (ADS)

    Schirripa Spagnolo, Giuseppe; Cozzella, Lorenzo; Simonetti, Carla

    2011-06-01

    When we buy an artwork object a certificate of authenticity contain specific details about the artwork. Unfortunately, these certificates are often exchanged between similar artworks: the same document is supplied by the seller to certificate the originality. In this way the buyer will have a copy of an original certificate to attest that the "not original artwork" is an original one. A solution for this problem would be to insert a system that links together the certificate and a specific artwork. To do this it is necessary, for a single artwork, to find unique, unrepeatable, and unchangeable characteristics. In this paper we propose a new lithography certification based on the color spots distribution, which compose the lithography itself. Due to the high resolution acquisition media available today, it is possible using analysis method typical of speckle metrology. In particular, in verification phase it is only necessary acquiring the same portion of lithography, extracting the verification information, using the private key to obtain the same information from the certificate and confronting the two information using a comparison threshold. Due to the possible rotation and translation it is applied image correlation solutions, used in speckle metrology, to determine translation and rotation error and correct allow to verifying extracted and acquired images in the best situation, for granting correct originality verification.

  8. Development of a human eye model incorporated with intraocular scattering for visual performance assessment

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng

    2012-07-01

    A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.

  9. Gill parasites of fish from two estuaries in northeastern Brazil: new hosts and geographical records.

    PubMed

    Golzio, Jéssica E S A; Falkenberg, Júlia M; Praxedes, Rayssa C G; Coutinho, Anderson S; Laurindo, Mylena K; Pessanha, André; Madi, Rubens R; Patrício, Joana; Vendel, Ana L; Souza, Geza T R; Melo, Cláudia M; Lacerda, Ana Carolina F

    2017-01-01

    Parasites are important components of communities and constitute great part of the biological diversity found in ecosystems, providing valuable information about their hosts and the environment in which they live. However, despite its importance, parasitic diversity is still not well known in some regions of Brazil, especially with respect to fish parasites in the Northeast Region. The present study aims to perform the survey of gill parasites of fish from two tropical estuaries located in northeastern Brazil: Paraíba and Mamanguape rivers. Two collections were made in each estuary, one during the dry period (November / 2013) and the other during the rainy season (July / 2014). The fish were caught using a beach seine net, dragged along the main channel margin. After the identification, biometry and necropsy of the fish, their parasites were collected, stored and identified. For each species of parasite, the values ​​of prevalence, mean intensity and mean abundance were calculated. Of the 882 examined fish, belonging to four species, 145 were parasitized by at least one species of parasite. In total, 18 taxa of parasites of the groups Monogenea, Digenea, Nematoda, Copepoda and Isopoda were recorded, being the copepod Acusicola brasiliensis the most abundant species of parasite.

  10. Birch Stands Growth Increase in Western Siberia

    NASA Technical Reports Server (NTRS)

    Kharuk, Viacheslav I.; Kuzmichev, Valeriy V.; Im, Sergey T.; Ranson, Kenneth J.

    2014-01-01

    Birch (Betula pendula Roth) growth within the Western Siberia forest-steppe was analyzed based on long-term (1897-2006) inventory data (height, diameter at breast height [dbh], and stand volume). Analysis of biometry parameters showed increased growth at the beginning of twenty-first century compared to similar stands (stands age = 40-60 years) at the end of nineteenth century. Mean height, dbh, and stem volume increased from 14 to 20 m, from 16 to 22 cm, and from approx. 63 to approx. 220 cu m/ha, respectively. Significant correlations were found between the stands mean height, dbh, and volume on the one hand, and vegetation period length (r(sub s) = 0.71 to 0.74), atmospheric CO2 concentration (r(sub s) = 0.71 to 0.76), and drought index (Standardized Precipitation-Evapotranspiration Index, r(sub s) = -0.33 to -0.51) on the other hand. The results obtained have revealed apparent climate-induced impacts (e.g. increase of vegetation period length and birch habitat drying due to drought increase) on the stands growth. Along with this, a high correlation of birch biometric parameters and [CO2] in ambient air indicated an effect of CO2 fertilization. Meanwhile, further drought increase may switch birch stand growth into decline and greater mortality as has already been observed within the Trans-Baikal forest-steppe ecotone.

  11. Imaging of dental material by polarization-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Dichtl, Sabine; Baumgartner, Angela; Hitzenberger, Christoph K.; Moritz, Andreas; Wernisch, Johann; Robl, Barbara; Sattmann, Harald; Leitgeb, Rainer; Sperr, Wolfgang; Fercher, Adolf F.

    1999-05-01

    Partial coherence interferometry (PCI) and optical coherence tomography (OCT) are noninvasive and noncontact techniques for high precision biometry and for obtaining cross- sectional images of biologic structures. OCT was initially introduced to depict the transparent tissue of the eye. It is based on interferometry employing the partial coherence properties of a light source with high spatial coherence ut short coherence length to image structures with a resolution of the order of a few microns. Recently this technique has been modified for cross section al imaging of dental and periodontal tissues. In vitro and in vivo OCT images have been recorded, which distinguish enamel, cemento and dentin structures and provide detailed structural information on clinical abnormalities. In contrast to convention OCT, where the magnitude of backscattered light as a function of depth is imaged, polarization sensitive OCT uses backscattered light to image the magnitude of the birefringence in the sample as a function of depth. First polarization sensitive OCT recordings show, that changes in the mineralization status of enamel or dentin caused by caries or non-caries lesions can result in changes of the polarization state of the light backscattered by dental material. Therefore polarization sensitive OCT might provide a new diagnostic imaging modality in clinical and research dentistry.

  12. Ultrafast High-Resolution Mass Spectrometric Finger Pore Imaging in Latent Finger Prints

    NASA Astrophysics Data System (ADS)

    Elsner, Christian; Abel, Bernd

    2014-11-01

    Latent finger prints (LFPs) are deposits of sweat components in ridge and groove patterns, left after human fingers contact with a surface. Being important targets in biometry and forensic investigations they contain more information than topological patterns. With laser desorption mass spectrometry imaging (LD-MSI) we record `three-dimensional' finger prints with additional chemical information as the third dimension. Here we show the potential of fast finger pore imaging (FPI) in latent finger prints employing LD-MSI without a classical matrix in a high- spatial resolution mode. Thin films of gold rapidly sputtered on top of the sample are used for desorption. FPI employing an optical image for rapid spatial orientation and guiding of the desorption laser enables the rapid analysis of individual finger pores, and the chemical composition of their excretions. With this approach we rapidly detect metabolites, drugs, and characteristic excretions from the inside of the human organism by a minimally-invasive strategy, and distinguish them from chemicals in contact with fingers without any labeling. The fast finger pore imaging, analysis, and screening approach opens the door for a vast number of novel applications in such different fields as forensics, doping and medication control, therapy, as well as rapid profiling of individuals.

  13. Ocular biometric characteristics of cataract patients in western China.

    PubMed

    Huang, Qing; Huang, Yongzhi; Luo, Qu; Fan, Wei

    2018-04-17

    We aimed to measure ocular biometric characteristics in older cataract patients from western China. Ocular biometry records were retrospectively analyzed for 6933 patients with cataracts (6933 eyes) at least 50 years old who were treated at West China Hospital of Sichuan University. Partial coherence laser interferometry gave the following population averages: axial length (AL), 24.32 ± 2.42 mm; anterior chamber depth (ACD), 3.08 ± 0.47 mm; keratometric power (K), 44.23 ± 1.66 diopters; and corneal astigmatism (CA), 1.00 ± 0.92 diopters. The percentage of individuals with AL > 26.5 mm was 13.66%, while the percentage with CA > 1.0 diopters was 35.54%. Mean AL and ACD showed a trend of decrease with increasing age (P < 0.001). AL correlated positively with ACD (Spearman coefficient, 0.542) and CA (0.111), but negatively with K (- 0.411) (all P < 0.01). K also correlated negatively with ACD (- 0.078, P < 0.01). These results show, for the first time, that older cataract patients from western China have similar ocular biometric characteristics as other populations. The high prevalence of severe axial myopia warrants further investigation.

  14. Combined laser-ray tracing and OCT system for biometry of the crystalline lens (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ruggeri, Marco; Maceo Heilman, Bianca M.; Yao, Yue; Chang, Yu-Cherng; Gonzalez, Alex; Rowaan, Cornelis; Mohamed, Ashik; Williams, Siobhan; Durkee, Heather A.; Silgado, Juan; Bernal, Andres; Arrieta-Quintero, Esdras; Ho, Arthur; Parel, Jean-Marie A.; Manns, Fabrice

    2017-02-01

    Age-related changes in the crystalline lens shape and refractive index gradient produce changes in dioptric power and high-order aberrations that influence the optics of the whole eye and contribute to a decrease in overall visual quality. Despite their key role, the changes in lens shape and refractive index gradient with age and accommodation and their effects on high-order aberrations are still not well understood. The goal of this project was to develop a combined laser ray tracing (LRT) and optical coherence tomography (OCT) system to measure high-order aberrations, shape and refractive index gradient in non-human primate and human lenses. A miniature motorized lens stretching system was built to enable imaging and aberrometry of the lens during simulated accommodation. A positioning system was also built to enable on- and off-axis OCT imaging and aberrometry for characterization of the peripheral defocus of the lens. We demonstrated the capability of the LRT-OCT system to produce OCT images and aberration measurements of crystalline lens with age and accommodation in vitro. In future work, the information acquired with the LRT-OCT system will be used to develop an accurate age-dependent lens model to predict the role of the lens in the development of refractive error and aberrations of the whole eye.

  15. Photonics and web engineering in Poland, WILGA 2009

    NASA Astrophysics Data System (ADS)

    Romaniuk, Ryszard S.

    2009-06-01

    The paper is a digest of work presented during a cyclic Ph.D. student symposium on Photonics and Web Engineering WILGA 2009. Symposium is organized by ISE PW in cooperation with professional organizations IEEE, SPIE, PSP and KEiT PAN. There are presented mainly Ph.D. and M.Sc. theses as well as achievements of young researchers. These papers, presented in such a big number, more than 250 in some years, are in certain sense a good digest of the condition of academic research capabilities in this branch of science and technology. The undertaken research subjects for Ph.D. theses in electronics is determined by the interest and research capacity (financial, laboratory and intellectual) of the young researchers and their tutors. Basically, the condition of academic electronics research depends on financing coming from applications areas. During Wilga 2009 there were organized, and thus the paper debates, the following topical sessions concerning applications of advanced electronics and photonics systems: merging of electronic systems and photonics, Internet engineering, distributed measurement systems, security in information technology, astronomy and cosmic technology, HEP experiments, environment protection, image processing and biometry. The paper contains also more general remarks concerning the workshops organized by and for the Ph.D. students in advanced photonics and electronics systems.

  16. Effect of zearalenone on circulating testosterone concentration, testicular and epididymal morphology and epididymal sperm characteristics in wild boars.

    PubMed

    Bielas, W; Niżański, W; Nicpoń, J; Nicpoń, J E; Partyka, A; Mordak, R; Nowak, M; Ciaputa, R

    2017-10-15

    This study investigated the effect of exposure to zearalenone (ZEN) and its metabolites on the characteristics of epididymal spermatozoa, testicular and epididymal biometry and histology, and the concentration of testosterone in blood plasma in male wild boars. The study was performed during more than one year on 18 clinically healthy male wild boars with initial and final body weight, of 39 ± 4 kg and 59 ± 3 kg, respectively. The animals were divided into two experimental groups (group I and group II) and one control group (group C) comprising 6 boars per group. Group I animals were administered per os pure zearalenone (ZEN) at 150 μg/kg BW for 7 consecutive days every two months, while group II animals received a dose of 50 μg/kg BW/day via feed that was naturally contaminated with ZEN. These male wild boars were exposed to ZEN over a period of 1 year. Control animals were fed a placebo. Testicles with epididymides of the boars were collected on the last day of the experiment within 3 min after slaughter. Blood samples were collected from each of the male wild boars. Testes and epididymides were measured and sampled for histological examination. Epididymides were dissected and epididymal spermatozoa were harvested. The spermatozoa were diluted with swine-specific BTS extender and stored at 17°C for 144 h. Sperm motility was analyzed with CASA, and other parameters including viability, acrosome integrity, DNA fragmentation index, lipid peroxidation and apoptosis were assessed with flow cytometry. In these wild boars, per os exposure to natural sources of ZEN or a combination of ZEN and its metabolites changed the testicular interstitium and led to modification of some epididymal sperm parameters. The interstitial glands in testes of experimental group I were markedly reduced and hyperemic with evident blood stasis in small capillaries. Also in group I were single degenerating seminiferous tubules. In both groups I and II, immediately after dilution of spermatozoa with BTS remarkable decreases in motility rate as well as in progressive motility and the subpopulation of cells with rapid movement were noted compared with the control group (P < 0.05). But unexpectedly, after 24 h incubation of boar semen in the BTS diluent, these sperm properties improved and were not significantly different from the control group. Thus, exposure to ZEN has no lasting but only a temporary, reversible effect on wild boar sperm motility. There was no influence of exposure to ZEN and its metabolites on the integrity of membranes, intensity of lipid peroxidation and apoptosis or on sperm chromatin structure. This study is the first using these direct measures of sperm motility and integrity to show a redundant adverse effect of ZEN exposure on wild boar sperm characteristics. There were no effects of exposure to ZEN and its metabolites on body weight, testicular and epididymal biometry, gonadosomatic index and the concentration of testosterone in blood plasma in the male wild boars. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Early indicators of cervical insufficiency assessed using magnetic resonance imaging of the cervix during pregnancy.

    PubMed

    Habib, Viviane Vieira Francisco; Araujo Júnior, Edward; Sun, Sue Yasaki; Júnior, Dirceu Faggion; Mattar, Rosiane; Szejnfeld, Jacob; Ajzen, Sergio Aron

    2015-04-01

    To establish the main characteristics of the cervix in pregnant women with cervical insufficiency, by means of magnetic resonance imaging (MRI). A prospective observational case-control study was conducted among 59 pregnant women with cervical insufficiency and 10 normal pregnant women, between their 10th and 28th weeks. The parameters analyzed in the MRI examinations were: precise identification of the cervix; presence of hyposignal at the internal orifice of the cervix; loss of definition of the periendocervical stromal zone (PESZ); presence of hyposignal content inside the amniotic sac (sludge sign) and anatomical and functional biometry of the cervix. Peripheral hyposignal was found in 41 (85.4%) and loss of definition of the PESZ was observed in 36 pregnant women (73.5%) with cervical insufficiency. Sludge was observed in 46 pregnant women with cervical insufficiency, and this was seen on MRI in 27 cases (58.7%). The mean anatomical and functional lengths of the cervix on MRI in the pregnant women with cervical insufficiency were 3.5 ± 0.8 cm (0.8-4.9 cm) and 28.7 ± 6.3 mm (9-41 mm). None of the normal pregnant women presented hyposignal loss of the PESZ and the sludge sign. MRI may be useful for evaluating the cervix and for early identification of signs of cervical insufficiency during pregnancy.

  18. Childhood myopia and parental smoking.

    PubMed

    Saw, S-M; Chia, K-S; Lindstrom, J M; Tan, D T H; Stone, R A

    2004-07-01

    To examine the relation between exposure to passive parental smoke and myopia in Chinese children in Singapore. 1334 Chinese children from three schools in Singapore were recruited, all of whom were participants in the Singapore Cohort study Of the Risk factors for Myopia (SCORM). Information on whether the father or mother smoked, number of years smoked, and the number of cigarettes smoked per day during the child's lifetime were derived. These data were correlated with contemporaneously obtained data available in SCORM. The children's cycloplegic autorefraction, corneal curvature radius, and biometry measures were compared with reported parental smoking history. There were 434 fathers (33.3%) and 23 mothers (1.7%) who smoked during their child's lifetime. There were no significant trends observed between paternal smoking and refractive error or axial length. After controlling for age, sex, school, mother's education, and mother's myopia, children with mothers who had ever smoked during their lifetime had more "positive" refractions (adjusted mean -0.28 D v -1.38 D) compared with children whose mother did not smoke (p = 0.012). The study found no consistent evidence of association between parental smoking and refractive error. There was a suggestion that children whose mothers smoked cigarettes had more hyperopic refractions, but the absence of a relation with paternal smoking and the small number of mothers who smoked in this sample preclude definite conclusions about a link between passive smoking exposure and myopia.

  19. Myo-inositol metabolism in appropriately grown and growth-restricted fetuses: a proton magnetic resonance spectroscopy study.

    PubMed

    Story, Lisa; Damodaram, Mellisa S; Supramaniam, Veena; Allsop, Joanna M; Mcguinness, Amy; Patel, Abhilasha; Wylezinska, Marzena; Kumar, Sailesh; Rutherford, Mary A

    2013-09-01

    Myo-inositol (Myo-ins) is a marker of neuroglial cells, being present in the astrocytes of brain tissue, but also functions as an osmolyte. Numbers of astrocytes are known to increase following injury to the brain. Growth-restricted fetuses are at increased risk of later neurodevelopmental impairments even in the absence of overt lesions and despite preserved/increased cerebral blood flow. This study aims to investigate brain Myo-ins metabolism in fetuses with intrauterine growth restriction (IUGR) and evidence of cerebral redistribution using magnetic resonance spectroscopy (MRS) at a short echo time. Biometry and Doppler assessment of blood flow was assessed using ultrasound in 28 fetuses with IUGR and 47 appropriately grown control subjects. MRI was used to exclude overt brain injury. Proton magnetic resonance spectroscopy of the fetal brain was then performed at an echo time of 42 ms to examine the Myo-ins:Choline (Cho), Myo-ins:Creatine (Cr) and Cho:Cr ratios. No alterations in brain Myo-ins:Cho, Myo-ins:Cr or Cho:Cr ratios were detected between appropriately grown and growth restricted fetuses. IUGR is not associated with a measureable difference in brain myo-inositol ratios. This may be due to the protective effects of preserved cerebral blood flow in growth restriction and comparable astrocyte numbers when compared to controls. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Methods in year 50: preserving the past and preparing for the future.

    PubMed

    Haux, R; Aronsky, D; Leong, T Y; McCray, A T

    2011-01-01

    Founded in 1962 and, therefore, the oldest international journal in medical informatics, Methods of Information in Medicine will publish its 50th volume in 2011. At the start of the journal's sixth decade, a discussion on the journal's profile seems appropriate. To report on the new opportunities for online access to Methods publications as well as on the recent strategic decisions regarding the journal's aims and editorial policies. Describing and analyzing the journal's aims and scope. Reflecting on recent publications and on the journal's development during the last decade. From 2011 forward all articles of Methods from 1962 until the present can be accessed online. Methods of Information in Medicine stresses the basic methodology and scientific fundamentals of processing data, information and knowledge in medicine and health care. Although the journal's major focus is on publications in medical informatics, it has never been restricted to publications only in this discipline. For example, articles in medical biometry, in or close to biomedical engineering, and, later, articles in bioinformatics continue to be a part of this journal. There is a continuous and, as it seems, ever growing overlap in the research methodology and application areas of the mentioned disciplines. As there is a continuing and even growing need for such a publication forum, Methods of Information in Medicine will keep its broad scope. As an organizational consequence, the journal's number of associate editors has increased accordingly.

  1. Advances of optical coherence tomography in myopia and pathologic myopia

    PubMed Central

    Ng, D S C; Cheung, C Y L; Luk, F O; Mohamed, S; Brelen, M E; Yam, J C S; Tsang, C W; Lai, T Y Y

    2016-01-01

    The natural course of high-axial myopia is variable and the development of pathologic myopia is not fully understood. Advancements in optical coherence tomography (OCT) technology have revealed peculiar intraocular structures in highly myopic eyes and unprecedented pathologies that cause visual impairment. New OCT findings include posterior precortical vitreous pocket and precursor stages of posterior vitreous detachment; peripapillary intrachoroidal cavitation; morphological patterns of scleral inner curvature and dome-shaped macula. Swept source OCT is capable of imaging deeper layers in the posterior pole for investigation of optic nerve pits, stretched and thinned lamina cribrosa, elongated dural attachment at posterior scleral canal, and enlargement of retrobulbar subarachnoid spaces. This has therefore enabled further evaluation of various visual field defects in high myopia and the pathogenesis of glaucomatous optic neuropathy. OCT has many potential clinical uses in managing visual impairing conditions in pathologic myopia. Understanding how retinal nerve fibers are redistributed in axial elongation will allow the development of auto-segmentation software for diagnosis and monitoring progression of glaucoma. OCT is indispensable in the diagnosis of various conditions associated with myopic traction maculopathy and monitoring of post-surgical outcomes. In addition, OCT is commonly used in the multimodal imaging assessment of myopic choroidal neovascularization. Biometry and topography of the retinal layers and choroid will soon be validated for the classification of myopic maculopathy for utilization in epidemiological studies as well as clinical trials. PMID:27055674

  2. The health burden of pollution: the impact of prenatal exposure to air pollutants

    PubMed Central

    Vieira, Sandra E

    2015-01-01

    Exposure to atmospheric pollutants in both open and closed environments is a major cause of morbidity and mortality that may be both controlled and minimized. Despite growing evidence, several controversies and disagreements exist among the studies that have analyzed the effects of prenatal pollutant exposure. This review article aims to analyze primary scientific evidence of the effects of air pollution during pregnancy and the impact of these effects on the fetus, infant health, and in particular, the respiratory system. We performed a review of articles from the PubMed and Web of Science databases that were published in English within the past 5 years, particularly those related to birth cohorts that began in pregnancy with follow-up until the first years of life. The largest reported effects are associated with prenatal exposure to particulate matter, nitrogen dioxide, and tobacco smoke. The primary effects affect birth weight and other parameters of fetal biometry. There is strong evidence regarding the impact of pollutants on morbidity secondary to respiratory problems. Growing evidence links maternal smoking to childhood asthma and wheezing. The role of passive maternal smoking is less clear. Great heterogeneity exists among studies. There is a need for additional studies on birth cohorts to monitor the relationship between the exposure of pregnant women to pollutants and their children’s progress during the first years of life. PMID:26089661

  3. Comparison of AL-Scan and IOLMaster 500 Partial Coherence Interferometry Optical Biometers.

    PubMed

    Hoffer, Kenneth J; Savini, Giacomo

    2016-10-01

    To investigate agreement between the ocular biometry measurements provided by a newer optical biometer, the AL-Scan (Nidek Co, Ltd., Gamagori, Japan) and those provided by the IOLMaster 500 (Carl Zeiss Meditec, Jena Germany), which are both based on partial coherence interferometry. Axial length, corneal power, and anterior chamber depth (corneal epithelium to lens) were measured in 86 eyes of 86 patients scheduled for cataract surgery using both biometers. All values were analyzed using a paired t test, the Pearson product moment correlation coefficient (r), and Bland-Altman plots. The mean axial length values of both instruments were exactly the same (23.46 ± 0.99 mm) for both) and showed excellent agreement and correlation. On the contrary, the AL-Scan measured a steeper mean corneal power by 0.08 diopters (D) at the 2.4-mm zone but by only 0.03 D at the 3.3-mm zone, only the former being statistically significant. The AL-Scan measured a deeper anterior chamber depth by 0.13 mm, which was statistically significant (P < .001). Agreement between the two units was good. However, the small but statistically significant difference in corneal power (at the IOLMaster-comparable 2.4-mm zone) and in the anterior chamber depth measurement make lens constant optimization necessary when calculating the intraocular lens power by means of theoretical formulas. [J Refract Surg. 2016;32(10):694-698.]. Copyright 2016, SLACK Incorporated.

  4. Phase-sensitive multiple reference optical coherence tomography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dsouza, Roshan I.; Subhash, Hrebesh; Neuhaus, Kai; Hogan, Josh; Wilson, Carol; Leahy, Martin

    2016-03-01

    Multiple reference OCT (MR-OCT) is a recently developed novel time-domain OCT platform based on a miniature reference arm optical delay, which utilizes a single miniature actuator and a partial mirror to generate recirculating optical delay for extended axial-scan range. MR-OCT technology promises to fit into a robust and cost-effective design, compatible with integration into consumer-level devices for addressing wide applications in mobile healthcare and biometry applications. Using conventional intensity based OCT processing techniques, the high-resolution structural imaging capability of MR-OCT has been recently demonstrated for various applications including in vivo human samples. In this study, we demonstrate the feasibility of implementing phase based processing with MR-OCT for various functional applications such as Doppler imaging and sensing of blood vessels, and for tissue vibrography applications. The MR-OCT system operates at 1310nm with a spatial resolution of ~26 µm and an axial scan rate of 600Hz. Initial studies show a displacement-sensitivity of ~20 nm to ~120 nm for the first 1 to 9 orders of reflections, respectively with a mirror as test-sample. The corresponding minimum resolvable velocity for these orders are ~2.3 µm/sec and ~15 µm/sec respectively. Data from a chick chorioallantoic membrane (CAM) model will be shown to demonstrate the feasibility of MR-OCT for imaging in-vivo blood flow.

  5. [Outdoor activity and myopia among 681 primary students in urban and rural regions of Beijing].

    PubMed

    Guo, Yin; Liu, Lijuan; Xu, Liang; Lü, Yanyun; Tang, Ping; Feng, Yi

    2014-01-21

    To explore the association between outdoor activity and myopia among 681 primary students from Beijing. School-based, cross-sectional investigation. Eye examination includes the visual acuity test, auto-refractor, slit lamp, ocular biometry and non-mydriatic fundus camera. Questionnaire includes regular items, near work, outdoor activity and social-economic status. The mean time spent outdoors was 1.6 ± 0.8 hours daily. Time spent on outdoor sports and outdoor leisure were 0.7 ± 0.1 hours daily, 1.0 ± 0.8 hours daily, respectively. Mean time of outdoor activity in urban was 1.1 ± 0.4 hours daily, compared with 2.2 ± 0.8 hours daily in rural (P = 0.000). In grade-1, total time spent outdoors is significantly different between myopia and non-myopia (1.4 ± 0.6 vs 1.8 ± 0.8 hours daily, P = 0.000), similar to outdoor leisure (0.8 ± 0.6 vs 1.1 ± 0.9 hours daily, P = 0.000). The same trend was also found in grade-4. The mean time spent outdoors was 1.6 ± 0.8 hours daily. Myopia spent a lower outdoor activity compared with non-myopia. More outdoor activity, e.g., in schools, may potentially be helpful to reduce the high prevalence of myopia in the young generation.

  6. Virtual reality imaging techniques in the study of embryonic and early placental health.

    PubMed

    Rousian, Melek; Koster, Maria P H; Mulders, Annemarie G M G J; Koning, Anton H J; Steegers-Theunissen, Régine P M; Steegers, Eric A P

    2018-04-01

    Embryonic and placental growth and development in the first trimester of pregnancy have impact on the health of the fetus, newborn, child and even the adult. This emphasizes the importance of this often neglected period in life. The development of three-dimensional transvaginal ultrasonography in combination with virtual reality (VR) opens the possibility of accurate and reliable visualization of embryonic and placental structures with real depth perception. These techniques enable new biometry and volumetry measurements that contribute to the knowledge of the (patho)physiology of embryonic and early placental health. Examples of such measurements are the length of complex structures like the umbilical cord, vitelline duct, limbs and cerebellum or the volume of the whole embryo and brain cavities. Moreover, for the first time, embryos can now be staged in vivo (Carnegie stages) and vasculature volumes of both the embryo and the early placenta can be measured when VR is combined with power Doppler signals. These innovative developments have already been used to study associations between periconceptional maternal factors, such as age, smoking, alcohol use, diet and vitamin status, and embryonic and early placental growth and development. Future studies will also focus on the identification of abnormal embryonic and early placental development already in the earliest weeks of pregnancy, which provides opportunities for early prevention of pregnancy complications. Copyright © 2018 IFPA, Elsevier Ltd. Published by Elsevier Ltd.. All rights reserved.

  7. Complete Placenta Previa: Ultrasound Biometry and Surgical Outcomes

    PubMed Central

    Wortman, Alison C.; Schaefer, Stephanie L.; McIntire, Donald D.; Sheffield, Jeanne S.; Twickler, Diane M.

    2018-01-01

    Objective  To evaluate the relationship between surgical outcomes and ultrasound measurement of placental extension beyond the cervical os in women with placenta previa. Study Design  This is a retrospective cohort study of singleton pregnancies with placenta previa undergoing third-trimester ultrasound and delivering at our institution from 2002 through 2011. For study purposes, an investigator measured placental extension, defined as the placental distance from the internal os across the placenta continuing out to the lowest placental edge. If morbidly adherent placentation was suspected, women were excluded. Receiver operating characteristic (ROC) curves were developed for pertinent surgical outcomes, and multivariate analysis was performed to determine the placental extension with the best predictive discriminatory zone. Results  In total, 157 women had placenta previa, ultrasound, and delivery data: 86 (55%) had a placental extension of <40 mm, and 71 (45%) had a placental extension of ≥40 mm. Women with placental extension of ≥40 mm had increased surgical time, blood loss > 2,000 mL, blood transfusion, and rate of peripartum hysterectomy. After multivariate analysis, only peripartum hysterectomy and surgical time > 90 minutes remained significant, p ≤ 0.05 and p ≤ 0.01, respectively. Conclusion  In women with placenta previa, the placental extension ultrasound measurement of ≥40 mm is a predictor of adverse surgical outcomes. PMID:29686936

  8. Complete Placenta Previa: Ultrasound Biometry and Surgical Outcomes.

    PubMed

    Wortman, Alison C; Schaefer, Stephanie L; McIntire, Donald D; Sheffield, Jeanne S; Twickler, Diane M

    2018-04-01

    Objective  To evaluate the relationship between surgical outcomes and ultrasound measurement of placental extension beyond the cervical os in women with placenta previa. Study Design  This is a retrospective cohort study of singleton pregnancies with placenta previa undergoing third-trimester ultrasound and delivering at our institution from 2002 through 2011. For study purposes, an investigator measured placental extension, defined as the placental distance from the internal os across the placenta continuing out to the lowest placental edge. If morbidly adherent placentation was suspected, women were excluded. Receiver operating characteristic (ROC) curves were developed for pertinent surgical outcomes, and multivariate analysis was performed to determine the placental extension with the best predictive discriminatory zone. Results  In total, 157 women had placenta previa, ultrasound, and delivery data: 86 (55%) had a placental extension of <40 mm, and 71 (45%) had a placental extension of ≥40 mm. Women with placental extension of ≥40 mm had increased surgical time, blood loss > 2,000 mL, blood transfusion, and rate of peripartum hysterectomy. After multivariate analysis, only peripartum hysterectomy and surgical time > 90 minutes remained significant, p ≤ 0.05 and p ≤ 0.01, respectively. Conclusion  In women with placenta previa, the placental extension ultrasound measurement of ≥40 mm is a predictor of adverse surgical outcomes.

  9. Fetal growth curves for an ethnically diverse military population: the American Institute of Ultrasound in Medicine-accredited platform experience.

    PubMed

    Elliott, Dawn; Patience, Troy; Boyd, Emily; Hume, Roderick F; Calhoun, Byron C; Napolitano, Peter G; Apodaca, Christina C

    2006-06-01

    To determine which fetal growth curve provided the best estimates of fetal weight for a cohort of ethnically diverse patients at sea level. The study consisted of a population of 1,729 fetuses examined at sea level between January 1, 1997, and June 30, 2000, at 18 weeks, 28 weeks, and term. Gestational age (GA) based on menstrual dates was confirmed or adjusted by crown-rump length or early second-trimester biometry. Fetal weight was estimated by using biparietal diameter, head circumference, abdominal circumference, and femur length. Our fetal growth curves were analyzed with fourth-order polynomial regression analysis, applying four previously defined formulae for fetal growth. Fetal growth curves for estimated fetal weight demonstrated the expected parabolic shape, which varied according to the formulae used. Our curve best fit the following equation: estimated fetal weight = 4.522 - 0.22 x GA age + 0.25 x GA(2) - 0.001 x GA(3) + 5.248 x 10(-6) x GA(4) (R2 = 0.976). SD increased in concordance with GA. Madigan Army Medical Center serves a racially mixed, culturally diverse, military community with unrestricted access to prenatal care. Determination of the optimal population-appropriate growth curve at the correct GA assists clinicians in identifying fetuses at risk for growth restriction or macrosomia and therefore at risk for increased perinatal morbidity and death.

  10. Correlations between different tonometries and ocular biometric parameters in patients with primary congenital glaucoma.

    PubMed

    Mendes, Marcio Henrique; Betinjane, Alberto Jorge; Quiroga, Veronica Andrea

    2013-01-01

    To identify the correlation between the difference of intraocular pressure measurements (IOP) obtained using the Goldmann applanation tonometer (GAT) and three others tonometers (Handheld applanation tonometer - HAT, Dynamic contour tonometer - DCT and Tono-Pen®) with biometric characteristics (corneal diameter, pachymetry, keratometry and axial length) in patients with congenital glaucoma. A cross-sectional study was performed on 46 eyes from 46 patients with congenital glaucoma. IOP measurements were obtained in all patients using GAT, HAT, DCT and Tono-Pen®. Keratometry, pachymetry, biometry and corneal diameter measurements were performed after the IOP measurement. The order of the tonometries was randomized. The correlations between the differences of IOP values of GAT and the other tonometers (Delta-IOP), and the different biometric parameters were studied. Tono-Pen® Delta IOP revealed moderate positive correlation to keratometry (r=0.41, p=0.004). The other Delta-IOPs showed no correlation with any of the biometric characteristics evaluated. IOP differences between GAT (gold standard) and GAT, HAT, DCT or Tono-Pen tonometers seem not to correlate with majority of ocular biometric characteristics. The only exception was the keratometry, which correlated in a positive and moderate way with Tono-Pen® Delta-IOP. This result suggests that the differences of IOP values of Tono-Pen® and GAT increase with the steepness of the cornea.

  11. Calculation of Ophthalmic Viscoelastic Device–Induced Focus Shift During Femtosecond Laser–Assisted Cataract Surgery

    PubMed Central

    de Freitas, Carolina P.; Cabot, Florence; Manns, Fabrice; Culbertson, William; Yoo, Sonia H.; Parel, Jean-Marie

    2015-01-01

    Purpose. To assess if a change in refractive index of the anterior chamber during femtosecond laser-assisted cataract surgery can affect the laser beam focus position. Methods. The index of refraction and chromatic dispersion of six ophthalmic viscoelastic devices (OVDs) was measured with an Abbe refractometer. Using the Gullstrand eye model, the index values were used to predict the error in the depth of a femtosecond laser cut when the anterior chamber is filled with OVD. Two sources of error produced by the change in refractive index were evaluated: the error in anterior capsule position measured with optical coherence tomography biometry and the shift in femtosecond laser beam focus depth. Results. The refractive indices of the OVDs measured ranged from 1.335 to 1.341 in the visible light (at 587 nm). The error in depth measurement of the refilled anterior chamber ranged from −5 to +7 μm. The OVD produced a shift of the femtosecond laser focus ranging from −1 to +6 μm. Replacement of the aqueous humor with OVDs with the densest compound produced a predicted error in cut depth of 13 μm anterior to the expected cut. Conclusions. Our calculations show that the change in refractive index due to anterior chamber refilling does not sufficiently shift the laser beam focus position to cause the incomplete capsulotomies reported during femtosecond laser–assisted cataract surgery. PMID:25626971

  12. The use of three-dimensional ultrasound does not improve training in fetal biometric measurements.

    PubMed

    Chan, Lin W; Ting, Yuen H; Lao, Terence T; Chau, Macy M C; Fung, Tak Y; Leung, Tak Y; Sahota, Daljit S; Lau, Tze K

    2011-09-01

    To investigate whether three-dimensional (3D) technology offers any advantage over two-dimensional (2D) ultrasound in fetal biometric measurement training. Ten midwives with no hands-on experience in ultrasound were randomized to receive training on 2D or 3D ultrasound fetal biometry assessment. Midwives were taught how to obtain fetal biometric measurements (biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL)) by a trainer. Subsequently, each midwife measured the parameters on another 10 fetuses. The same set of measurements was repeated by the trainer. The percentage deviation between the midwives' and the trainer's measurements was determined and compared between training groups. Time required for completion was recorded. Frozen images were reviewed by another sonographer to assess the image quality using a standardized scoring system. The median time for the complete set of measurements was significantly shorter in the 2D than in 3D group (13.4 min versus 17.8 min, P = 0.03). The mean percentage deviations did not reach statistical significance between the two groups except for FL (3.83% in 2D group versus 2.23% in 3D group (P = 0.046)). There were no significant differences in the quality scores. This study showed that the only demonstrable advantage of 3D ultrasound was a slightly more accurate measurement of FL, at the expense of a significantly longer time required.

  13. International estimated fetal weight standards of the INTERGROWTH-21st Project.

    PubMed

    Stirnemann, J; Villar, J; Salomon, L J; Ohuma, E; Ruyan, P; Altman, D G; Nosten, F; Craik, R; Munim, S; Cheikh Ismail, L; Barros, F C; Lambert, A; Norris, S; Carvalho, M; Jaffer, Y A; Noble, J A; Bertino, E; Gravett, M G; Purwar, M; Victora, C G; Uauy, R; Bhutta, Z; Kennedy, S; Papageorghiou, A T

    2017-04-01

    Estimated fetal weight (EFW) and fetal biometry are complementary measures used to screen for fetal growth disturbances. Our aim was to provide international EFW standards to complement the INTERGROWTH-21 st Fetal Growth Standards that are available for use worldwide. Women with an accurate gestational-age assessment, who were enrolled in the prospective, international, multicenter, population-based Fetal Growth Longitudinal Study (FGLS) and INTERBIO-21 st Fetal Study (FS), two components of the INTERGROWTH-21 st Project, had ultrasound scans every 5 weeks from 9-14 weeks' until 40 weeks' gestation. At each visit, measurements of fetal head circumference (HC), biparietal diameter, occipitofrontal diameter, abdominal circumference (AC) and femur length (FL) were obtained blindly by dedicated research sonographers using standardized methods and identical ultrasound machines. Birth weight was measured within 12 h of delivery by dedicated research anthropometrists using standardized methods and identical electronic scales. Live babies without any congenital abnormality, who were born within 14 days of the last ultrasound scan, were selected for inclusion. As most births occurred at around 40 weeks' gestation, we constructed a bootstrap model selection and estimation procedure based on resampling of the complete dataset under an approximately uniform distribution of birth weight, thus enriching the sample size at extremes of fetal sizes, to achieve consistent estimates across the full range of fetal weight. We constructed reference centiles using second-degree fractional polynomial models. Of the overall population, 2404 babies were born within 14 days of the last ultrasound scan. Mean time between the last scan and birth was 7.7 (range, 0-14) days and was uniformly distributed. Birth weight was best estimated as a function of AC and HC (without FL) as log(EFW) = 5.084820 - 54.06633 × (AC/100) 3  - 95.80076 × (AC/100) 3  × log(AC/100) + 3.136370 × (HC/100), where EFW is in g and AC and HC are in cm. All other measures, gestational age, symphysis-fundus height, amniotic fluid indices and interactions between biometric measures and gestational age, were not retained in the selection process because they did not improve the prediction of EFW. Applying the formula to FGLS biometric data (n = 4231) enabled gestational age-specific EFW tables to be constructed. At term, the EFW centiles matched those of the INTERGROWTH-21 st Newborn Size Standards but, at < 37 weeks' gestation, the EFW centiles were, as expected, higher than those of babies born preterm. Comparing EFW cross-sectional values with the INTERGROWTH-21 st Preterm Postnatal Growth Standards confirmed that preterm postnatal growth is a different biological process from intrauterine growth. We provide an assessment of EFW, as an adjunct to routine ultrasound biometry, from 22 to 40 weeks' gestation. However, we strongly encourage clinicians to evaluate fetal growth using separate biometric measures such as HC and AC, as well as EFW, to avoid the minimalist approach of focusing on a single value. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology. © 2016 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

  14. Seed and Germination Characteristics of 20 Amazonian Liana Species

    PubMed Central

    Roeder, Mareike; Ferraz, Isolde D. K.; Hölscher, Dirk

    2013-01-01

    Lianas are an important component of tropical forests, and may reach their highest densities in disturbed areas. However, information on seed and germination characteristics is scarce. Twenty Amazon liana species were screened for their germination characteristics, including light dependence, tolerance of desiccation and of alternating temperatures; these characteristics are considered important for the germination success in areas with relatively open canopies. Between 31–1,420 seeds per species were available, as 15 species seeds came from one mother plant. We studied seed biometry and conducted germination trials with fresh seeds (12 h light daily, or dark) and desiccated seeds at 25 °C. Germination at alternating temperatures (20/30 °C, 15/35 °C) was analyzed for nine species. Of the 20 species, eight species with the largest seeds had desiccation sensitive seeds; this is the first record for species of four genera and one family, where only desiccation tolerant seeds are otherwise recorded. Light-dependent germination was found in three species (0.01–0.015 g) and is the first record for two; however, results were based on seeds from one plant per species. Alternating temperatures of 15/35 °C decreased final germination of four out of nine species, and response to 20/30 °C cycles varied compared to constant 25 °C. Seed and germination characteristics of the species ranged from pioneer to climax traits indicating that establishment of lianas from seeds may be confined to species specific niches. PMID:27137363

  15. Estimation of prenatal aorta intima-media thickness in ultrasound examination

    NASA Astrophysics Data System (ADS)

    Veronese, Elisa; Poletti, Enea; Cosmi, Erich; Grisan, Enrico

    2012-03-01

    Prenatal events such as intrauterine growth restriction have been shown to be associated with an increased thickness of abdominal aorta in the fetus. Therefore the measurement of abdominal aortic intima-media thickness (aIMT) has been recently considered a sensitive marker of artherosclerosis risk. To date measure of aortic diameter and of aIMT has been performed manually on US fetal images, thus being susceptible to intra- and inter- operator variability. This work introduces an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from videos recorded during routine third trimester ultrasonographic fetal biometry. Firstly, in each frame, the algorithm locates and segments the region corresponding to aorta by means of an active contour driven by two different external forces: a static vector field convolution force and a dynamic pressure force. Then, in each frame, the mean diameter of the vessel is computed, to reconstruct the cardiac cycle: in fact, we expect the diameter to have a sinusoidal trend, according to the heart rate. From the obtained sinusoid, we identify the frames corresponding to the end diastole and to the end systole. Finally, in these frames we assess the aIMT. According to its definition, we consider as aIMT the distance between the leading edge of the blood-intima interface, and the leading edge of the media-adventitia interface on the far wall of the vessel. The correlation between end-diastole and end-systole aIMT automatic and manual measures is 0.90 and 0.84 respectively.

  16. Standardisation of crown-rump length measurement.

    PubMed

    Ioannou, C; Sarris, I; Hoch, L; Salomon, L J; Papageorghiou, A T

    2013-09-01

    Correct estimation of gestational age is essential for any study of ultrasound biometry and for everyday clinical practice. However, inconsistency in pregnancy dating may occur through differences in measurement methods or errors during measurement. In the INTERGROWTH-21(st) Project, pregnancies are dated by the last menstrual period, provided that it is certain and associated with a regular menstrual cycle, and the gestational age by dates concurs with a first-trimester ultrasound crown-rump length (CRL) estimation. Hence, there was a need to standardise CRL measurement methodology across the study sites in this international, multicentre project to avoid systematic differences in dating. To achieve uniformity we undertook the following steps: the ultrasound technique was standardised by disseminating an illustrated, operating manual describing CRL plane landmarks and calliper application, and posters describing the correct acquisition technique were disseminated for quick reference. To ensure that all ultrasonographers understood the methodology, they forwarded a log-book to the INTERGROWTH-21(st) Ultrasound Coordinating Unit, containing the answers to a written test on the manual material and five images of a correctly acquired CRL. Interpretation of CRL was also standardised by ensuring that the same CRL regression formula was used across all study sites. These methods should minimise potential systematic errors in dating associated with pooling data from different health institutions, and represent a model for standardising CRL measurement in future studies. © 2013 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2013 RCOG.

  17. Prediction of fetal compromise in labor.

    PubMed

    Prior, Tomas; Mullins, Edward; Bennett, Phillip; Kumar, Sailesh

    2014-06-01

    The majority of intrapartum fetal hypoxia occurs in uncomplicated pregnancies. Current intrapartum monitoring techniques have not resulted in a reduction in the incidence of cerebral palsy in term neonates. We report the development of a composite risk score to allow risk stratification of normal pregnancies before labor. Six hundred one women were recruited to this prospective observational study. All women underwent an ultrasound examination before active labor, during which fetal biometry and fetal Doppler flow resistance indices were measured. A composite risk score, amalgamating data from the umbilical artery, middle cerebral artery, and umbilical vein, was then developed and correlated with intrapartum outcomes. In cases with the highest composite risk scores, the incidence of fetal compromise (the primary outcome) was 80.0% compared with just 15.3% in cases with the lowest risk scores (relative risk 5.2, 95% confidence interval 2.7-10.1). These cases were also at increased risk of cesarean delivery (53.3% compared with 3.4%, P<.001) and of developing a fetal heart rate pattern considered pathologic by National Institute for Health and Clinical Excellence criteria (P=.003). No significant variation in Apgar scores or umbilical artery pH was observed. Intrapartum fetal compromise remains a significant global health issue. The composite risk score reported here can identify fetuses at both high risk and low risk of a subsequent diagnosis of intrapartum fetal compromise. This may enable more judicious use of current intrapartum fetal monitoring techniques, which are hampered by low specificity. II.

  18. Distribution of the Crystalline Lens Power In Vivo as a Function of Age.

    PubMed

    Jongenelen, Sien; Rozema, Jos J; Tassignon, Marie-José

    2015-11-01

    To observe the age-related changes in crystalline lens power in vivo in a noncataractous European population. Data were obtained though Project Gullstrand, a multicenter population study with data from healthy phakic subjects between 20 and 85 years old. One randomly selected eye per subject was used. Lens power was calculated using the modified Bennett-Rabbetts method, using biometry data from an autorefractometer, Oculus Pentacam, and Haag-Streit Lenstar. The study included 1069 Caucasian subjects (490 men, 579 women) with a mean age of 44.2 ± 14.2 years and mean lens power of 24.96 ± 2.18 diopters (D). The average lens power showed a statistically significant decrease as a function of age, with a steeper rate of decrease after the age of 55. The highest crystalline lens power was found in emmetropic eyes and eyes with a short axial length. The correlation of lens power with different refractive components was statistically significant for axial length (r = -0.523, P < 0.01) and anterior chamber depth (r = -0.161, P < 0.01), but not for spherical equivalent and corneal power (P > 0.05). This in vivo study showed a monotonous decrease in crystalline lens power with age, with a steeper decline after 55 years. While this finding fundamentally concurs with previous in vivo studies, it is at odds with studies performed on donor eyes that reported lens power increases after the age of 55.

  19. Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China.

    PubMed

    Yu, Ji-Guo; Zhong, Jie; Mei, Zhong-Ming; Zhao, Fang; Tao, Na; Xiang, Yi

    2017-04-26

    To evaluate the distribution of biometric parameters and corneal astigmatism using the IOLMaster device before phacoemulsification in cataract patients in Central China. Consecutive cataract patients were recruited at the Central Hospital of Wuhan between January 2015 and June 2016. Ocular axial length (AL), keratometry values, anterior chamber depth (ACD) and horizontal corneal diameter (white to white [WTW]) of each cataract-affected eye were measured with the IOLMaster device. The study evaluated 3209 eyes of 2821 cataract patients. The mean AL, ACD, and WTW were 24.38 ± 2.47 mm, 3.15 ± 0.48 mm, and 11.63 ± 0.43 mm, respectively. Corneal astigmatism of 0.51-1.00 diopters (D) was the most common range of values (34.96%). A total of 10.56% patients exhibited a corneal astigmatism greater than 2.0 D. The flat and steep keratometry values gradually increased with age. The mean ACD and WTW showed increasing trends as the AL increased (P < 0.001). When the AL was shorter than 26.0 mm, the keratometry decreased as AL increased. The against-the-rule (ATR) astigmatism proportion increased with age and the with-the-rule (WTR) astigmatism proportion decreased with age. The profile of ocular biometric data and corneal astigmatism may help ophthalmologists improve their surgical procedures and make an appropriate IOL choice to gain a high quality of postoperative vision.

  20. Some directions in ecological theory.

    PubMed

    Kendall, Bruce E

    2015-12-01

    The role of theory within ecology has changed dramatically in recent decades. Once primarily a source of qualitative conceptual framing, ecological theories and models are now often used to develop quantitative explanations of empirical patterns and to project future dynamics of specific ecological systems. In this essay, I recount my own experience of this transformation, in which accelerating computing power and the widespread incorporation of stochastic processes into ecological theory combined to create some novel integration of mathematical and statistical models. This stronger integration drives theory towards incorporating more biological realism, and I explore ways in which we can grapple with that realism to generate new general theoretical insights. This enhanced realism, in turn, may lead to frameworks for projecting ecological responses to anthropogenic change, which is, arguably, the central challenge for 21st-century ecology. In an era of big data and synthesis, ecologists are increasingly seeking to infer causality from observational data; but conventional biometry provides few tools for this project. This is a realm where theorists can and should play an important role, and I close by pointing towards some analytical and philosophical approaches developed in our sister discipline of economics that address this very problem. While I make no grand prognostications about the likely discoveries of ecological theory over the coming century, you will find in this essay a scattering of more or less far-fetched ideas that I, at least, think are interesting and (possibly) fruitful directions for our field.

  1. Glaucoma and clinical characteristics in Vietnamese Americans.

    PubMed

    Peng, Pai-Huei; Manivanh, Richard; Nguyen, Ngoc; Weinreb, Robert N; Lin, Shan C

    2011-08-01

    To assess the proportions of glaucoma types and clinical characteristics in Vietnamese Americans in a single-center, retrospective study. Medical charts of Vietnamese-American patients who visited a single private practice in Northern California from 1998-2007 were reviewed. The main outcome measures included the distribution and characteristics of glaucoma types, and clinical parameters associated with the presence of various glaucomas. Data from 2247 patients aged 18-98 years were reviewed. Glaucoma was determined for 305 patients (13.6%). Among this group, 54.8% had primary open-angle glaucoma (POAG), 26.9% had primary angle-closure glaucoma (PACG), 13.4% had mixed mechanism glaucoma (MMG), and 4.9% had secondary glaucoma. In the MMG group (41 patients), 27 patients who initially had open angles developed narrow angles and underwent laser peripheral iridotomy (LPI) with a mean follow up of 6.4 years from the time of iridotomy. The other 13 patients had glaucoma progression with open angles after LPI. One POAG patient had neovascular glaucoma due to retinal vein occlusion several years later. Compared to the PACG group, the MMG group had significantly lower baseline intraocular pressure (25.0 vs. 20.2 mmHg, p = 0.007) but with no difference in biometry. POAG is the major type of glaucoma in this clinic-based Vietnamese population. However, Vietnamese appear to have a relatively higher proportion of PACG than Caucasians and those of African descent. It is recommended that gonioscopy be part of the regular eye check-up for adult Vietnamese patients.

  2. Ultrasonography and optical low-coherence interferometry compared in the chicken eye.

    PubMed

    Penha, Alexandra Marcha; Burkhardt, Eva; Schaeffel, Frank; Feldkaemper, Marita P

    2012-06-01

    To compare ocular biometry [anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD), and axial length (AL)] using A-scan ultrasonography and optical low-coherence interferometry (OLCI) in the chicken eye. Two-week-old chicks (n = 42) were measured. Bland-Altman plots and repeatability and correlation analyses were calculated for both methods. There was a high correlation between both methods for ACD (r = 0.6144, p < 0.0001), VCD (r = 0.9595, p < 0.0001), and AL (r = 0.9290, p < 0.0001) but not for LT (r = 0.1604, p = 0.144). Measurements by OLCI were more consistent (smaller coefficients of variation and higher intraclass correlation). Bland-Altman plots showed that ultrasound provided larger values for LT, VCD, and AL but not for ACD [differences between ultrasound and OLCI (mean ± SD): ACD = -0.11 ± 0.12 mm; LT = 0.10 ± 0.09 mm; VCD = 0.25 ± 0.08 mm; AL = 0.50 ± 0.16 mm]. A high correlation between both techniques was found for three of the four parameters (ACD, VCD, and AL). However, as the absolute values were different, both techniques cannot replace each other mainly because (1) one is non-contact and the other contact and can induce a minor indentation of the cornea and (2) each device uses different types of waves that cross the ocular interfaces differently. While consistency and repeatability were better by OLCI, a disadvantage is that, different from humans, it can only be used in anesthetized chicks.

  3. Association between Refractive Errors and Ocular Biometry in Iranian Adults

    PubMed Central

    Hashemi, Hassan; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Shariati, Mohammad; Miraftab, Mohammad; Yekta, Abbasali; Ostadimoghaddam, Hadi; Fotouhi, Akbar

    2015-01-01

    Purpose: To investigate the association between ocular biometrics such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and corneal power (CP) with different refractive errors. Methods: In a cross-sectional study on the 40 to 64-year-old population of Shahroud, random cluster sampling was performed. Ocular biometrics were measured using the Allegro Biograph (WaveLight AG, Erlangen, Germany) for all participants. Refractive errors were determined using cycloplegic refraction. Results: In the first model, the strongest correlations were found between spherical equivalent with axial length and corneal power. Spherical equivalent was strongly correlated with axial length in high myopic and high hyperopic cases, and with corneal power in high hyperopic cases; 69.5% of variability in spherical equivalent was attributed to changes in these variables. In the second model, the correlations between vitreous chamber depth and corneal power with spherical equivalent were stronger in myopes than hyperopes, while the correlations between lens thickness and anterior chamber depth with spherical equivalent were stronger in hyperopic cases than myopic ones. In the third model, anterior chamber depth + lens thickness correlated with spherical equivalent only in moderate and severe cases of hyperopia, and this index was not correlated with spherical equivalent in moderate to severe myopia. Conclusion: In individuals aged 40-64 years, corneal power and axial length make the greatest contribution to spherical equivalent in high hyperopia and high myopia. Anterior segment biometric components have a more important role in hyperopia than myopia. PMID:26730304

  4. Fetal subcutaneous tissue measurements in pregnancy as a predictor of neonatal total body composition.

    PubMed

    O'Connor, Clare; Doolan, Anne; O'Higgins, Amy; Segurado, Ricardo; Sheridan-Pereiraet, Margaret; Turner, Michael J; Stuart, Bernard; Kennelly, Máireád M

    2014-10-01

    The purpose of this study was to examine the relationship between prenatal measures of subcutaneous tissue as surrogate markers of fetal nutritional status and correlate them with neonatal total body composition. This prospective longitudinal study of 62 singleton pregnancies obtained serial biometry and subcutaneous tissue measurements at 28, 33 and 38 weeks gestation. These measurements were then correlated with neonatal body composition, which was analysed using the PEAPOD™ Infant Body Composition System (Cosmed USA, Concord, CA, USA). At 38 weeks gestation, fetal abdominal subcutaneous tissue (FAST) in millimetres was significantly associated with infant fat mass at delivery (+64 g per mm of FAST, p < 0.001). Thigh fat (TF) at 28 weeks gestation was associated with infant fat mass at delivery (+79 g/mm TF, p = 0.023). TF at 38 weeks gestation was associated with infant fat mass (+63/mm TF, p = 0.004). TF and FAST at 38 weeks were also predictive of both birth weight and increased abdominal circumference (AC) (p = 0.001) with FAST measurement predicting an additional 5.7 mm in AC per millimetre of FAST (p = 0.002) and TF predicting an additional 6.9 mm per mm of TF (p = 0.002). We believe that this study further validates the use of prenatal measures of subcutaneous tissue and may help to highlight fetuses at risk of newborn adiposity and metabolic syndrome. © 2014 John Wiley & Sons, Ltd.

  5. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    PubMed

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p < 0.00001). The number of predictions within +/- 0.5 D, +/- 1.0 D and +/- 2.0 D of the expected outcome was 62.5%, 92.4% and 99.9% with PCI, compared with 45.5%, 77.3% and 98.4% with ultrasound, respectively (p < 0.00001). The 2-variable ACD method resulted in an average error in PCI predictions of 0.46 D, which was significantly higher than the error in the 5-variable method (p < 0.001). The accuracy of IOL power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  6. Race- and Sex-Related Differences in Retinal Thickness and Foveal Pit Morphology

    PubMed Central

    Wagner-Schuman, Melissa; Dubis, Adam M.; Nordgren, Rick N.; Lei, Yuming; Odell, Daniel; Chiao, Hellen; Weh, Eric; Fischer, William; Sulai, Yusufu; Dubra, Alfredo

    2011-01-01

    Purpose. To examine sex- and race-associated differences in macular thickness and foveal pit morphology by using spectral-domain optical coherence tomography (SD-OCT). Methods. One hundred eighty eyes of 90 healthy patients (43 women, 47 men) underwent retinal imaging with spectral-domain OCT. The lateral scale of each macular volume scan was corrected for individual differences in axial length by ocular biometry. From these corrected volumes, Early Treatment Diabetic Retinopathy Study (ETDRS) grids of retinal thickness were generated and compared between the groups. Foveal morphology was measured with previously described algorithms. Results. Compared with the Caucasians, the Africans and African Americans had reduced central subfield thickness. Central subfield thickness was also reduced in the women compared with the men, although the women also showed significant thinning in parafoveal regions. There was no difference between the sexes in foveal pit morphology; however, the Africans/African Americans had significantly deeper and broader foveal pits than the Caucasians. Conclusions. Previous studies have reported race- and sex-associated differences in macular thickness, and the inference has been that these differences represent similar anatomic features. However, the data on pit morphology collected in the present study reveal an important and significant variation. Between the sexes, the differences are due to global variability in retinal thickness, whereas the variation in thickness observed between the races appears to be driven by differences in foveal pit morphology. These differences have important implications for the use of SD-OCT in detecting and diagnosing retinal disease. PMID:20861480

  7. Creating a blended learning module in an online master study programme in oncology.

    PubMed

    Mayer, Benjamin; Ring, Christina; Muche, Rainer; Rothenbacher, Dietrich; Schmidt-Strassburger, Uta

    2015-01-01

    The medical faculty of Ulm University has launched the postgraduate master online study programme Advanced Oncology (AO) in 2010. We describe the challenges in developing an e-learning module using the example of a medical biometry course, focusing the implementation of the course material and our single-loop learning experience after the first students have finished and evaluated the lecture. Programme participants are qualified medical doctors and researchers in biomedical areas related to the field of oncology. The study programme provides the majority of lectures online via didactic videos accompanied by one-week attendance seminars. Supplementary learning materials include review articles, supportive reading material, multiple choice questions, and exercises for each unit. Lecture evaluations based on specific questions concerning learning environment and information learned, each measured on a five-point Likert scale. Lecture videos were implemented following the classical triad of the didactic process, using oncological examples from practice to teach. The online tutorial support offered to students was hardly used, thus we enhanced faculty presence during the face-to-face seminars. Lecture evaluations improved after revising the learning material on the basis of the first AO student cohort's comments. Developing and implementing an online study programme is challenging with respect of maximizing the information students learn due to limited opportunities for personal contact between lecturers and students. A more direct interaction of lecturers and students in a blended learning setting outperforms a mere web-based contact in terms of learning advantage and students' satisfaction, especially for complex methodological content.

  8. Fetal Growth Restriction Is Associated With Malaria in Pregnancy: A Prospective Longitudinal Study in Benin.

    PubMed

    Briand, Valérie; Saal, Jessica; Ghafari, Caline; Huynh, Bich-Tram; Fievet, Nadine; Schmiegelow, Christentze; Massougbodji, Achille; Deloron, Philippe; Zeitlin, Jennifer; Cot, Michel

    2016-08-01

    Few studies have evaluated the effect of malaria on intrauterine growth restriction on the basis of the fetal growth rate, rather than just the small-for-gestational age z score. Here, we assessed the impact of malaria on IUGR, using data from a longitudinal, ultrasonography-based follow-up study of Beninese women. A total of 1016 women were followed up from gestational week 17 to delivery. Malaria was detected every month. Women underwent ultrasonography 4 times for gestational age determination and fetal biometry. We assessed the effect of malaria on birth weight-for-gestational age z score (n = 735 women) and fetal growth velocity (n = 664), defined as a change in fetal weight z score over time. Malaria was detected in 43% of women. Fetal growth velocity was negative overall, decreasing further at the end of the third trimester. Women with ≥2 malarial parasite infections tended to have lower z scores than uninfected women. Malaria both in early and late pregnancy was associated with a reduction in fetal growth velocity, which occurred either immediately or with a delay after infection. We confirmed the deleterious effect of malaria during both early and late pregnancy on fetal growth. This stresses the importance of starting preventive measures against malaria as early as possible during pregnancy. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  9. A comparison of interocular differences in patients with pigment dispersion syndrome.

    PubMed

    Yip, Leonard W; Sothornwit, Nisa; Berkowitz, Jonathan; Mikelberg, Frederick S

    2009-01-01

    Pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG) are characterized by loss of iris pigment because of reverse pupillary block. The loss of iris pigment is manifested as transillumination defects. Differences in ocular anatomy have been found between subjects with PDS and controls. Our study aims to see if differences in interocular anatomic features are also related to differences in the quantity of transillumination defects between eyes. This is an observational case series of 30 eyes of 15 subjects with PDS/PG in at least 1 eye. Patients underwent refraction, exophthalmometry, corneal and anterior chamber analysis by Pentacam, biometry, A-scan, ultrasound biomicroscopy, and anterior segment digital photography. The Pentacam mean central radii of the posterior corneal surface (cornea back Rm), vertical central radius of curvature of the posterior corneal surface (cornea back Rv), and keratometric power deviation (influence of the posterior surface of the cornea on refractive power) were statistically different between eyes with greater pigment loss and eyes with lesser pigment loss. Eyes with greater pigment loss had a larger back radius of corneal curvature and a correspondingly numerically smaller keratometric power deviation. Other measurements of ocular anatomy were not statistically significant. A flatter curvature of the posterior corneal surface of the eye is associated with increased pigment loss in PDS and PG. The authors postulate that this could result in a difference in the biomechanical properties of the cornea, increased deformation with blinking, and a pumping action resulting in the reverse pupil block of PDS.

  10. Comparison of anterior segment parameters and axial length measurements performed on a Scheimpflug device with biometry function and a reference optical biometer.

    PubMed

    Muzyka-Woźniak, Maria; Oleszko, Adam

    2018-04-26

    To compare measurements of axial length (AL), corneal curvature (K), anterior chamber depth (ACD) and white-to-white (WTW) distance on a new device combining Scheimpflug camera and partial coherence interferometry (Pentacam AXL) with a reference optical biometer (IOL Master 500). To evaluate differences between IOL power calculations based on the two biometers. Ninety-seven eyes of 97 consecutive cataract or refractive lens exchange patients were examined preoperatively on IOL Master 500 and Pentacam AXL units. Comparisons between two devices were performed for AL, K, ACD and WTW. Intraocular lens (IOL) power targeting emmetropia was calculated with SRK/T and Haigis formulas on both devices and compared. There were statistically significant differences between two devices for all measured parameters (P < 0.05), except ACD (P = 0.36). Corneal curvature measured with Pentacam AXL was significantly flatter then with IOL Master. The mean difference in AL was clinically insignificant (0.01 mm; 95% LoA 0.16 mm). Pentacam AXL yielded higher IOL power in 75% of eyes for Haigis formula and in 62% of eyes for SRK/T formula, with a mean difference within ± 0.5 D for 72 and 86% of eyes, respectively. There were statistically significant differences between AL, K and WTW measurements obtained with the compared biometers. Flatter corneal curvature measurements on Pentacam AXL necessitate formulas optimisation for Pentacam AXL.

  11. The relationship of newborn adiposity to fetal growth outcome based on birth weight or the modified neonatal growth assessment score

    PubMed Central

    Lee, W; Riggs, T; Koo, W; Deter, RL; Yeo, L; Romero, R

    2013-01-01

    Objectives (1) Develop reference ranges of neonatal adiposity using air displacement plethysmography. (2) Use new reference ranges for neonatal adiposity to compare two different methods of evaluating neonatal nutritional status. Methods Three hundred and twenty-four normal neonates (35–41 weeks post-menstrual age) had body fat (%BF) and total fat mass (FM, g) measured using air displacement plethysmography shortly after delivery. Results were stratified for 92 of these neonates with corresponding fetal biometry using two methods for classifying nutritional status: (1) population-based weight percentiles; and (2) a modified neonatal growth assessment score (m3NGAS51). Results At the 50th percentile, &BF varied from 7.7% (35 weeks) to 11.8% (41 weeks), while the corresponding 50th percentiles for total FM were 186–436g. Among the subset of 92 neonates, no significant differences in adiposity were found between small for gestational age (SGA), appropriate for gestational age (AGA), and large for gestational age (LGA) groups using population-based weight standards. Classification of the same neonates using m3NGAS51 showed significant differences in mean %BF between corresponding groups. Conclusions Population-based weight criteria for neonatal nutritional status can lead to misclassification on the basis of adiposity. A neonatal growth assessment score, that considers the growth potential of several anatomic parameters, appears to more effectively classify under-and over-nourished newborns. PMID:22494346

  12. Biometric characteristics of eyes with central serous chorioretinopathy.

    PubMed

    Oh, Jong-Hyun; Oh, Jaeryung; Togloom, Ariunaa; Kim, Seong-Woo; Huh, Kuhl

    2014-03-13

    To investigate the biometric characteristics of eyes with idiopathic central serous chorioretinopathy (CSC). Medical records of 52 consecutive patients with unilateral CSC were reviewed. Central serous chorioretinopathy was diagnosed using spectral-domain optical coherence tomography (SD-OCT) and fluorescein angiography. Data collected for comparison with fellow eyes were refractive error, biometric measurements using partial coherence interferometry, and SD-OCT parameters. Mean time from subjective symptom onset to initial visit was 8.3 ± 12.29 weeks. Mean axial length (AL) was shorter in CSC eyes than in fellow eyes by 0.24 ± 0.379 mm (P < 0.001), and mean anterior chamber depth (ACD) was shallower in CSC eyes than in fellow eyes by 0.03 ± 0.088 mm (P = 0.021). Central serous chorioretinopathy eyes also had thicker subfoveal choroidal thickness (CT) than fellow eyes by 34.0 ± 45.93 μm (P < 0.001). Differences in spherical equivalents between CSC and fellow eyes correlated with AL differences (r = -0.690, P < 0.001) and CT differences (r = 0.473, P = 0.001). On multiple linear regression analysis, the differences in ACD between CSC and fellow eyes were significantly correlated with AL differences (P = 0.032) and symptom duration (P = 0.019). Biometric characteristics such as AL and ACD were different between eyes with CSC and fellow eyes. Variations in biometry, which correlated with CT differences, might be related to differences in refractive errors between eyes.

  13. A Prospective Study of Pterygium Excision and Conjunctival Autograft With Human Fibrin Tissue Adhesive: Effects on Vision, Refraction, and Corneal Topography.

    PubMed

    Misra, Stuti; Craig, Jennifer P; McGhee, Charles N J; Patel, Dipika V

    2014-01-01

    This study aimed to investigate changes in visual acuity, corneal parameters, and topographic parameters after pterygium surgery. A prospective observational study was conducted. Twenty eyes of 20 participants undergoing pterygium excision with conjunctival autograft secured using human fibrin tissue adhesive were included in the study. All the participants were assessed preoperatively and 1 and 3 months postoperatively. The parameters included subjective refraction, visual acuity, and pterygium size (pterygium horizontal corneal length [PHCL]) and corneal tomography by Pentacam rotating Scheimpflug tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany). The astigmatic changes were calculated using vector analysis. The mean age of participants was 49.3 ± 12.1 years. Mean PHCL was 2.68 ± 0.30 mm. The mean best corrected visual acuity preoperatively was 6/7.5, improving significantly to 6/6 at 1 month (P = 0.001) with this improvement remaining stable at 3 months postoperatively (P = 0.34). There was no significant change in subjective astigmatism, however, mean topographic astigmatism decreased significantly at 1 month (4.36 diopter, P < 0.01) and remained unchanged at 3 months (P < 0.01). Greater PHCL was associated with greater changes in corneal astigmatism. Significant improvements and early stabilization of visual acuity and topographic astigmatism confirm the optical benefits of pterygium excision. These data also suggest a significant advantage of performing pterygium before rather than simultaneously with or after cataract surgery by enabling the most accurate biometry.

  14. Height, weight, body mass index and ocular biometry in patients with sickle cell disease.

    PubMed

    Osuobeni, Ebi Peter; Okpala, Iheanyi; Williamson, Tom H; Thomas, Peter

    2009-03-01

    To investigate the effects of physical size on refractive error and the dimensions of optical components in sickle cell disease (SCD). The design was cross sectional. Height and weight of adult patients suffering from SCD were measured, and body mass index (BMI) was calculated. Anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and axial length (AL) were measured using A-scan ultrasonography. Corneal radius of curvature (CR) was measured using a keratometer. Non-cycloplegic refractive error was determined subjectively. Subjects with SC genotype were significantly taller than those with SS genotype. In the unadjusted data, height was correlated with VCD [p = 0.02, 0.44 mm deeper per 10 cm increase in height, 95% CI (0.65, 8.25)] and AL [p = 0.03, 0.42 mm longer for every 10 cm increase in height, 95%CI (0.49, 7.99)]. The relationship between height, VCD and AL was absent after adjustment for age, gender, genotype and weight. BMI (kg m(-2)) was correlated with AL/CR ratio in both unadjusted (p = 0.04, -0.10 decrease per 1 kg m(-2), 95% CI (-0.018, -0.001) and adjusted data (p = 0.05, -0.10 decrease per 10 kg m(-2), 95% CI (-0.0189, 0.0001). Refractive error was not related to height, weight or BMI. Physical size does not affect refractive error or optical components in adult patients with SCD.

  15. Assessment of intraocular measurements in neonatal foals and association with gender, laterality, and body weight: a clinical study.

    PubMed

    Valentini, Simona; Castagnetti, Carolina; Musella, Vincenzo; Spinella, Giuseppe

    2014-01-01

    Objective of this study was to describe intraocular measurements in newly born foals (1-7 days of age) and assess the association between globe measurements and gender, laterality, and body weight. B-scan ultrasonographic biometry was performed on both eyes of 22 healthy foals (44 eyes) ages 1-7 days using a 10-MHz transducer. Intraocular measurements (anterior chamber depth, central lens thickness, vitreous chamber depth, axial globe length, longitudinal globe length, lens poles distance) were carried out using the ultrasound internal calipers. The influence of gender (male or female), laterality (right or left eye), and body weight ("light" <48 kg; "heavy" ≥48 kg) on ocular measurements was analysed by the Student t test. Values of P<0.05 were accepted as significant for all analyses. Mean anterior chamber depth was 2.2±0.5 mm (Standard Deviation); central lens thickness was 9.9±0.8 mm; vitreous chamber depth was 15.5±1.1 mm; axial globe length was 27.6±1.6 mm; longitudinal globe length was 35.8±1.2 mm, and lens poles distance was 16.4±1.0 mm. Intraocular measurements were not influenced by gender, laterality nor body weight. This study provides reference values for intraocular measurements in neonatal foals and may be useful in the diagnosis and treatment of congenital and acquired pathologies involving the globe.

  16. Assessment of Intraocular Measurements in Neonatal Foals and Association with Gender, Laterality, and Body Weight: A Clinical Study

    PubMed Central

    Valentini, Simona; Castagnetti, Carolina; Musella, Vincenzo; Spinella, Giuseppe

    2014-01-01

    Objective of this study was to describe intraocular measurements in newly born foals (1–7 days of age) and assess the association between globe measurements and gender, laterality, and body weight. B-scan ultrasonographic biometry was performed on both eyes of 22 healthy foals (44 eyes) ages 1–7 days using a 10-MHz transducer. Intraocular measurements (anterior chamber depth, central lens thickness, vitreous chamber depth, axial globe length, longitudinal globe length, lens poles distance) were carried out using the ultrasound internal calipers. The influence of gender (male or female), laterality (right or left eye), and body weight (“light” <48 kg; “heavy” ≥48 kg) on ocular measurements was analysed by the Student t test. Values of P<0.05 were accepted as significant for all analyses. Mean anterior chamber depth was 2.2±0.5 mm (Standard Deviation); central lens thickness was 9.9±0.8 mm; vitreous chamber depth was 15.5±1.1 mm; axial globe length was 27.6±1.6 mm; longitudinal globe length was 35.8±1.2 mm, and lens poles distance was 16.4±1.0 mm. Intraocular measurements were not influenced by gender, laterality nor body weight. This study provides reference values for intraocular measurements in neonatal foals and may be useful in the diagnosis and treatment of congenital and acquired pathologies involving the globe. PMID:25296286

  17. Comparison of parametric methods for modeling corneal surfaces

    NASA Astrophysics Data System (ADS)

    Bouazizi, Hala; Brunette, Isabelle; Meunier, Jean

    2017-02-01

    Corneal topography is a medical imaging technique to get the 3D shape of the cornea as a set of 3D points of its anterior and posterior surfaces. From these data, topographic maps can be derived to assist the ophthalmologist in the diagnosis of disorders. In this paper, we compare three different mathematical parametric representations of the corneal surfaces leastsquares fitted to the data provided by corneal topography. The parameters obtained from these models reduce the dimensionality of the data from several thousand 3D points to only a few parameters and could eventually be useful for diagnosis, biometry, implant design etc. The first representation is based on Zernike polynomials that are commonly used in optics. A variant of these polynomials, named Bhatia-Wolf will also be investigated. These two sets of polynomials are defined over a circular domain which is convenient to model the elevation (height) of the corneal surface. The third representation uses Spherical Harmonics that are particularly well suited for nearly-spherical object modeling, which is the case for cornea. We compared the three methods using the following three criteria: the root-mean-square error (RMSE), the number of parameters and the visual accuracy of the reconstructed topographic maps. A large dataset of more than 2000 corneal topographies was used. Our results showed that Spherical Harmonics were superior with a RMSE mean lower than 2.5 microns with 36 coefficients (order 5) for normal corneas and lower than 5 microns for two diseases affecting the corneal shapes: keratoconus and Fuchs' dystrophy.

  18. In situ effects of metal contamination from former uranium mining sites on the health of the three-spined stickleback (Gasterosteus aculeatus, L.).

    PubMed

    Le Guernic, Antoine; Sanchez, Wilfried; Bado-Nilles, Anne; Palluel, Olivier; Turies, Cyril; Chadili, Edith; Cavalié, Isabelle; Delahaut, Laurence; Adam-Guillermin, Christelle; Porcher, Jean-Marc; Geffard, Alain; Betoulle, Stéphane; Gagnaire, Béatrice

    2016-08-01

    Human activities have led to increased levels of various pollutants including metals in aquatic ecosystems. Increase of metallic concentrations in aquatic environments represents a potential risk to exposed organisms, including fish. The aim of this study was to characterize the environmental risk to fish health linked to a polymetallic contamination from former uranium mines in France. This contamination is characterized by metals naturally present in the areas (manganese and iron), uranium, and metals (aluminum and barium) added to precipitate uranium and its decay products. Effects from mine releases in two contaminated ponds (Pontabrier for Haute-Vienne Department and Saint-Pierre for Cantal Department) were compared to those assessed at four other ponds outside the influence of mine tailings (two reference ponds/department). In this way, 360 adult three-spined sticklebacks (Gasterosteus aculeatus) were caged for 28 days in these six ponds before biomarker analyses (immune system, antioxidant system, biometry, histology, DNA integrity, etc.). Ponds receiving uranium mine tailings presented higher concentrations of uranium, manganese and aluminum, especially for the Haute-Vienne Department. This uranium contamination could explain the higher bioaccumulation of this metal in fish caged in Pontabrier and Saint-Pierre Ponds. In the same way, many fish biomarkers (antioxidant and immune systems, acetylcholinesterase activity and biometric parameters) were impacted by this environmental exposure to mine tailings. This study shows the interest of caging and the use of a multi-biomarker approach in the study of a complex metallic contamination.

  19. Marine diatoms sustain growth of bivalves in a Mediterranean lagoon

    NASA Astrophysics Data System (ADS)

    Pernet, Fabrice; Malet, Nathalie; Pastoureaud, Annie; Vaquer, André; Quéré, Claudie; Dubroca, Laurent

    2012-02-01

    Carbon stable isotopes and fatty acids were measured in the suspended particulate organic matter (POM) of the Thau lagoon to study its qualitative temporal changes in relation to environmental factors and to identify the food sources of bivalves over a one-yr-cycle in relation to their growth. Reciprocally, the impact of shellfish farming on POM was also studied. Oysters and mussels were sampled and measured for biometry, stable isotopes and fatty acid composition. Water samples were collected at two sites, both inside and outside of the shellfish farming area, to determine concentrations in POM, chlorophyll a (Chl a) and stable isotopes. Carbon isotopes and fatty acids in bivalves reflected seasonal changes in food sources, which varied consistently with the environment. Seasonal changes in δ13C and fatty acids in the bivalves suggested that dietary phytoplankton contribution varied according to season. Terrestrial organic matter and bacteria can contribute to the diet of bivalves during non-bloom periods. Mussels seemed to rely more on diatoms and less on terrestrial organic matter and bacteria than oysters did, particularly when phytoplankton biomass was low during the summer. Although one- and two-yr-old oysters showed similar δ13C, their fatty acid dynamics differed slightly. Periods of high growth rate in bivalves were mainly fuelled by diatoms, thus highlighting the importance of seasonal blooms of microphytoplankton during the critical period of bivalve growth and gamete production. Although there was no significant effect of shellfish farms on Chl a and POM δ13C, consistent differences indicate that stable isotopes could be used successfully to investigate the effects of bivalve aquaculture.

  20. What factors are associated with myopia in young adults? A survey study in Taiwan Military Conscripts.

    PubMed

    Lee, Yin-Yang; Lo, Chung-Ting; Sheu, Shwu-Jiuan; Lin, Julia L

    2013-02-05

    We investigated the independent impact of potential risk factors on myopia in young adults. A survey study was conducted with male military conscripts aged 18 to 24 years between February 2010 and March 2011 in Taiwan. The participants were examined using non-cycloplegic autorefraction and biometry. The participants provided data about potential risk factors, including age, parental myopia, education, near work, outdoor activity, and urbanization. Myopia was defined as the mean spherical equivalent of the right eye of ≤ 0.5 diopters (D). Among 5145 eligible participants, 5048 (98.11%) had refraction and questionnaire data available; 2316 (45.88%) of these received axial length examination. The prevalence of myopia was 86.1% with a mean refractive error of -3.66 D (SD = 2.73) and an axial length of 25.40 mm (SD = 1.38). Older age, having myopic parents, higher education level, more time spent reading, nearer reading distance, less outdoor activity, and higher urbanization level were associated with myopia and longer axial length. More computer use was related to longer axial length. All risk factors associated with myopia also were predictors of high myopia (≤ -6.0 D), with the exception of outdoor activity. Finally, an interaction analysis showed shorter axial length was associated with more time spent outdoors only at high urbanization level. Older age, parental myopia, higher education level, more near work, less outdoor activity, and higher urbanization level were independent predictors of myopia. These data provided evidence to the multifactorial nature of myopia in young men in Taiwan.

  1. Non-invasive measurements of the dynamic changes in the ciliary muscle, crystalline lens morphology, and anterior chamber during accommodation with a high-resolution OCT.

    PubMed

    Esteve-Taboada, José J; Domínguez-Vicent, Alberto; Monsálvez-Romín, Daniel; Del Águila-Carrasco, Antonio J; Montés-Micó, Robert

    2017-07-01

    The purpose of the study was to assess non-invasively the changes in the anterior chamber eye, crystalline lens morphology, and ciliary muscle during accommodation by means of an anterior chamber optical coherence tomographer (OCT), and correlate them with vergence. Twenty-five eyes of twenty-five healthy subjects, whose mean age was 29.9±7.1 years, were included and measured with an anterior chamber OCT. The central corneal thickness (CCT), anterior chamber depth (ACD), anterior crystalline lens radius of curvature (ALRC), crystalline lens thickness (CLT), and ciliary muscle area (CMA) were measured for each participant at 0, -1, -2, and -3 D of target vergence. A linear model was used to assess the correlation of each eye parameter with the vergence demand. The mean CCT showed no change for all the accommodative stimuli. The mean ACD and ALRC decreased with the vergence, about 4.5 and 30 % at -3 D, respectively. On the contrary, the CLT and CMA showed an opposite tendency, where the mean CLT was increased by 4.0 % and the mean CMA was done by 26% at -3 D. Statistical significant differences (p < 0.001) were obtained among all vergences for each eye metric, except for the CCT (p = 0.76). The ACD and ALRC decreased about 2 and 10 % per dioptre of accommodation, respectively; whereas the CLT and CMA increased about 2 and 9 %, respectively. These results add knowledge regarding the understanding of accommodation and give new perspectives for biomechanics and biometry.

  2. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity.

    PubMed

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-09-01

    Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Cross sectional study. Children (<16 years) enrolled from January 2014 to December 2014 with a history of laser treatment for ROP and examined for refractive and biometric status. Thirty-six children presenting to us at the mean age of 7.37 ± 3.07 years (6-15 years) were included. Mean spherical equivalent (SE) was -4.05 D ± 5.10. 75% were myopic, with high astigmatism in 31%. Higher lens thickness (P = 0.03) and higher SE (P = 0.002) at 1 year postnatal age were predictors of larger SE. 79.4% achieved a favorable functional outcome (visual acuity ≥20/40). 5.88% achieved unsatisfactory outcome (<20/200) despite having a favorable structural outcome. There are a substantial number of children who develop myopia and high astigmatism while undergoing laser treatment for ROP. We found myopia in our cohort to be lenticular and greater axial length contributing to the development of high myopia. An initial large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low.

  3. Nearwork in early-onset myopia.

    PubMed

    Saw, Seang-Mei; Chua, Wei-Han; Hong, Ching-Ye; Wu, Hui-Min; Chan, Wai-Ying; Chia, Kee-Seng; Stone, Richard A; Tan, Donald

    2002-02-01

    To determine the relationship of nearwork and myopia in young elementary school-age children in Singapore. A cross-sectional study of 1005 school children aged 7 to 9 years was conducted in two schools in Singapore. Cycloplegic autorefraction, keratometry, and biometry measurements were performed. In addition, the parents completed a detailed questionnaire on nearwork activity (books read per week, reading in hours per day and diopter hours [addition of three times reading, two times computer use, and two times video games use in hours per day]). Other risk factors, such as parental myopia, socioeconomic status, and light exposure history, were assessed. In addition to socioeconomic factors, several nearwork indices were associated with myopia in these young children. The multivariate adjusted odds ratio of higher myopia (at least -3.0 D) for children who read more than two books per week was 3.05 (95% confidence interval [CI], 1.80-5.18). However, the odds ratios of higher myopia for children who read more than 2 hours per day or with more than 8 diopter hours (1.50; 95% CI, 0.87-2.55 and 1.04; 95% CI, 0.61-1.78, respectively) were not significant, after controlling for several factors. Children aged 7 to 9 years with a greater current reading exposure were more likely to be myopic. This association of reading and myopia in a young age cohort was greater than the strength of the reading association generally found in older myopic subjects. Whether these results identify an association of early-onset myopia with nearwork activity or other potentially confounding factors is discussed.

  4. Facial biometry of Amazon indigenous people of the Xingu River - Perspectives on genetic and environmental contributions to variation in human facial morphology.

    PubMed

    Barbosa, M; Vieira, E P; Quintão, C C A; Normando, D

    2016-08-01

    To evaluate facial morphology of non-mixed indigenous people living in the Xingu region. Studies on these populations report that the total genetic diversity is as high as that observed for other continental populations. On the other hand, eating habits are different between indigenous and urban population, as indigenous people still have traditional habits. The sample consisted of 106 indigenous subjects, in permanent dentition stage, belonging to four groups: Arara-Laranjal (n = 35), Arara-Iriri (n = 20), Xikrin-Kaiapó (n = 24), and Assurini (n = 27). Standardized facial photographs were obtained, and fourteen measurements were analyzed. Intra- and intergroup homogeneities were examined by discriminant analysis, followed by anova and Kruskal-Wallis tests. Sexual dimorphism to each village was analyzed by Student's t-test or Mann-Whitney test, at p < 0.05. Significant facial differences were found between male and female, indicating that sex data should not be grouped for intergroup comparison. Discriminant analysis showed a large intergroup heterogeneity, while an intragroup homogeneity was found, especially for females. It was also observed that some morphological features of the face are specific to some villages, regardless of ethnicity. Facial morphological characteristics were strongly different among groups, even comparing villages from the same ethnicity. Furthermore, a low diversity within groups was observed. Our findings, supported by previous reports on genetics and eating habits in these populations, reinforce the role of the genetic determination on craniofacial morphology. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Eye growth in the second decade of life: implications for the implantation of a multifocal intraocular lens.

    PubMed

    Wilson, M Edward; Trivedi, Rupal H; Burger, Berdine M

    2009-12-01

    There is a growing interest in multifocal intraocular lens (IOL) implantation in children because they lose accommodation when a cataract is removed. Many have assumed that very little, if any, eye growth occurs in the second decade of life. Multifocal IOL implantation requires precise biometry to arrive at the correct IOL power for spectacle independence. If the eye grows and the refraction becomes myopic, spectacle dependence may return. Therefore, knowing when the eye has completed its growth is critical to the decision of when to implant a multifocal IOL. Ninety-eight eyes were analyzed retrospectively. Each had at least two axial length (AL) measurements using immersion A-scan ultrasound in the second decade of life. Globe AL was 23.36 +/- 1.52 mm at initial measurement and 23.89 +/- 1.64 mm at last measurement. Measurement data show variable growth throughout the second decade of life. Based on our data, a theoretical patient was constructed with an AL at age 10 of 23.11 mm, who would need an IOL power of 21.5 for emmetropia. That same patient would have an AL of 23.76 mm (IOL power of 19.5) at age 15 and 24.41 mm (IOL power of 17.5) at age 20. That is a 4-diopter change in the IOL power need. Axial eye growth continues throughout the second decade of life, at least to age 20. These data have important implications for the use of multifocal IOLs in the preteen and teenage years.

  6. Pharmacologically and Edinger-Westphal stimulated accommodation in rhesus monkeys does not rely on changes in anterior chamber pressure.

    PubMed

    He, Lin; Wendt, Mark; Glasser, Adrian

    2014-08-01

    This study was undertaken to understand the role of anterior chamber pressure (ACP) during pharmacological and Edinger-Westphal (EW) stimulated accommodation in anesthetized monkeys. Experiments were performed on one iridectomized eye each of 7 anesthetized adolescent rhesus monkeys. Accommodation was induced by EW stimulation (n = 2) and intravenous administration of 0.25-4.0 mg/kg pilocarpine (n = 6). Accommodative refractive and biometric changes were measured with continuous 60 Hz infrared photorefraction (n = 6) and 100 Hz A-scan ultrasound biometry (n = 1). An ocular perfusion system was used to measure and manipulate ACP. Pressure was recorded via a 27-gauge needle in the anterior chamber connected to a pressure transducer (n = 7). The needle was also connected to a fluid reservoir to allow ACP to be manipulated and clamped (n = 4) by raising or lowering the fluid reservoir. In all six pharmacologically stimulated monkeys ACP increased during accommodation, from 0.70 to 2.38 mmHg, four of which showed pressure decreases preceding the pressure increases. Two eyes also showed increases in ACP during EW-stimulated accommodation of 2.8 and 7.2 mmHg. ACP increased with increasing EW stimulus amplitudes (n = 2). Clamping or externally manipulating ACP had no effect on resting refraction or on EW and pharmacologically stimulated accommodation in four eyes. The results show that EW stimulated and pharmacologically stimulated accommodation do not rely on ACP in rhesus monkeys. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Precise measurement of scleral radius using anterior eye profilometry.

    PubMed

    Jesus, Danilo A; Kedzia, Renata; Iskander, D Robert

    2017-02-01

    To develop a new and precise methodology to measure the scleral radius based on anterior eye surface. Eye Surface Profiler (ESP, Eaglet-Eye, Netherlands) was used to acquire the anterior eye surface of 23 emmetropic subjects aged 28.1±6.6years (mean±standard deviation) ranging from 20 to 45. Scleral radius was obtained based on the approximation of the topographical scleral data to a sphere using least squares fitting and considering the axial length as a reference point. To better understand the role of scleral radius in ocular biometry, measurements of corneal radius, central corneal thickness, anterior chamber depth and white-to-white corneal diameter were acquired with IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany). The estimated scleral radius (11.2±0.3mm) was shown to be highly precise with a coefficient of variation of 0.4%. A statistically significant correlation between axial length and scleral radius (R 2 =0.957, p<0.001) was observed. Moreover, corneal radius (R 2 =0.420, p<0.001), anterior chamber depth (R 2 =0.141, p=0.039) and white-to-white corneal diameter (R 2 =0.146, p=0.036) have also shown statistically significant correlations with the scleral radius. Lastly, no correlation was observed comparing scleral radius to the central corneal thickness (R 2 =0.047, p=0.161). Three-dimensional topography of anterior eye acquired with Eye Surface Profiler together with a given estimate of the axial length, can be used to calculate the scleral radius with high precision. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  8. Errors Associated with IOLMaster Biometry as a Function of Internal Ocular Dimensions

    PubMed Central

    Faria-Ribeiro, Miguel; Lopes-Ferreira, Daniela; López-Gil, Norberto; Jorge, Jorge; González-Méijome, José Manuel

    2014-01-01

    Purpose To evaluate the error in the estimation of axial length (AL) with the IOLMaster partial coherence interferometry (PCI) biometer and obtain a correction factor that varies as a function of AL and crystalline lens thickness (LT). Methods Optical simulations were produced for theoretical eyes using Zemax-EE software. Thirty-three combinations including eleven different AL (from 20 mm to 30 mm in 1 mm steps) and three different LT (3.6 mm, 4.2 mm and 4.8 mm) were used. Errors were obtained comparing the AL measured for a constant equivalent refractive index of 1.3549 and for the actual combinations of indices and intra-ocular dimensions of LT and AL in each model eye. Results In the range from 20 mm to 30 mm AL and 3.6–4.8 mm LT, the instrument measurements yielded an error between −0.043 mm and +0.089 mm. Regression analyses for the three LT condition were combined in order to derive a correction factor as a function of the instrument measured AL for each combination of AL and LT in the theoretical eye. Conclusions The assumption of a single “average” refractive index in the estimation of AL by the IOLMaster PCI biometer only induces very small errors in a wide range of combinations of ocular dimensions. Even so, the accurate estimation of those errors may help to improve accuracy of intra-ocular lens calculations through exact ray tracing, particularly in longer eyes and eyes with thicker or thinner crystalline lenses. PMID:24766863

  9. Unilateral Congenital Cataract: Clinical Profile and Presentation.

    PubMed

    Khokhar, Sudarshan; Jose, Cijin P; Sihota, Ramanjit; Midha, Neha

    2018-03-01

    To study the clinical profile and presentation of children with unilateral cataract. In this hospital-based, observational, cross-sectional study, patients 15 years of age or younger who presented with unilateral cataract were recruited. Cases of cataract secondary to causes such as trauma or uveitis were excluded. Age at detection and presentation, distance from the treatment center, presenting complaints, cataract morphology, and biometry were noted for each case. A total of 76 patients were recruited. Most patients presented with complaints of leukocoria. Persistent fetal vasculature accounted for 27.6% of cases and was the most common identifiable cause of cataract in this study. Subsequently, patients were divided into two groups: no persistent fetal vasculature (control) and persistent fetal vasculature. A male predominance was noted in both groups. The mean age at detection was 27.58 ± 37.02 and 6.17 ± 8.42 months and the mean age at presentation was 55.613 ± 45.21 and 14.83 ± 17.75 months in the control and persistent fetal vasculature groups, respectively. In the persistent fetal vasculature group, a significant difference was noted in the axial length, keratometry, and corneal diameter between the affected and normal eyes (P = .027, .00176, and .0114, respectively). In the control group, this difference was observed only in keratometry readings (P = .0464). The mean distance traveled by patients to reach the treatment center was 211 km. Persistent fetal vasculature is an important and less identified cause of unilateral cataract. A significant delay is noted in the detection and presentation of unilateral cataract. [J Pediatr Ophthalmol Strabismus. 2018;55(2):107-112.]. Copyright 2017, SLACK Incorporated.

  10. Comparison of biometric measurements obtained by the Verion Image-Guided System versus the auto-refracto-keratometer.

    PubMed

    Velasco-Barona, Cecilio; Cervantes-Coste, Guadalupe; Mendoza-Schuster, Erick; Corredor-Ortega, Claudia; Casillas-Chavarín, Nadia L; Silva-Moreno, Alejandro; Garza-León, Manuel; Gonzalez-Salinas, Roberto

    2018-06-01

    To compare the biometric measurements obtained from the Verion Image-Guided System to those obtained by auto-refracto-keratometer in normal eyes. This is a prospective, observational, comparative study conducted at the Asociación para Evitar la Ceguera en México I.A.P., Mexico. Three sets of keratometry measurements were obtained using the image-guided system to assess the coefficient of variation, the within-subject standard deviation and intraclass correlation coefficient (ICC). A paired Student t test was used to assess statistical significance between the Verion and the auto-refracto-keratometer. A Pearson's correlation coefficient (r) was obtained for all measurements, and the level of agreement was verified using Bland-Altman plots. The right eyes of 73 patients were evaluated by each platform. The Verion coefficient of variation was 0.3% for the flat and steep keratometry, with the ICC being greater than 0.9 for all parameters measured. Paired t test showed statistically significant differences between groups (P = 0.0001). A good correlation was evidenced for keratometry values between platforms (r = 0.903, P = 0.0001 for K1, and r = 0.890, P = 0.0001). Bland-Altman plots showed a wide data spread for all variables. The image-guided system provided highly repeatable corneal power and keratometry measurements. However, significant differences were evidenced between the two platforms, and although values were highly correlated, they showed a wide data spread for all analysed variables; therefore, their interchangeable use for biometry assessment is not advisable.

  11. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500).

    PubMed

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je

    2017-03-01

    To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.

  12. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500)

    PubMed Central

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun

    2017-01-01

    Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576

  13. Refractive errors in the adult pakistani population: the national blindness and visual impairment survey.

    PubMed

    Shah, Shaheen P; Jadoon, Mohammad Z; Dineen, Brendan; Bourne, Rupert R A; Johnson, Gordon J; Gilbert, Clare E; Khan, Mohammad D

    2008-01-01

    To determine the prevalence of refractive error (RE) and spectacle wear and to explore the need for spectacle correction in adults (30 years or older) in Pakistan. Multi-stage, cluster random sampling national survey. Each subject had their medical history taken, visual acuity measured, and underwent autorefraction, biometry and fundus examination. Those that presented with visual acuity of less than 6/12 in either eye underwent more detailed examination, including corrected distance visual acuity measurement (autorefraction results placed in a trial lens frame). Myopia was defined as a spherical equivalent of worse than -0.5D, hypermetropia as greater than +0.5D, and astigmatism as greater than 0.75D. Spectacle need (i.e., those that improved from unaided VA with spectacle correction) was determined along with the spectacle coverage, defined as the proportion of need that was met (by the participant's own spectacles). The crude prevalence of myopia, hypermetropia and astigmatism was 36.5%, 27.1%, and 37%, respectively. The prevalence of spectacle wear in phakic participants was 4.0%, significantly lower than for those who were pseudo/aphakic (41.7%). Just over a quarter (25.8%) of spectacle wearers presenting with visual impairment (< 6/12) were able to improve their vision when retested with their autorefraction prescription. The overall spectacle coverage (6/12 cutoff) was 15.1%. This survey provides the first reliable national estimates. RE services are not covering the majority of the population in need and the provision of spectacle correction, as a highly cost effective treatment for visual impairment, needs addressing within the country's national eye care program.

  14. Morphology, biometry, and taxonomy of freshwater and marine interstitial cyphoderia (cercozoa: euglyphida).

    PubMed

    Todorov, Milcho; Golemansky, Vassil; Mitchell, Edward A D; Heger, Thierry J

    2009-01-01

    Good taxonomy is essential for ecological, biogeographical, and evolutionary studies of any group of organisms. Therefore, we performed detailed light- and scanning electron microscopy investigations on the shell ultrastructure and biometric analyses of the morphometric variability of five freshwater and marine interstitial testate amoebae of the genus Cyphoderia (C. trochus var. amphoralis, C. ampulla, C. margaritacea var. major, C. compressa, and C. littoralis), isolated from different populations in Bulgaria and Switzerland. Our aims were (1) to clarify the morphological characteristics of these taxa, and (2) to compare the morphology of a given taxon (C. ampulla) among different locations in Bulgaria and Switzerland as a first step towards an assessment of the geographical variation within a supposedly cosmopolitan taxon. Four of the studied taxa are characterized by a well-expressed main-size class and by a small size range of all the characters and can be defined as size-monomorphic species. Based on these results, the following systematic changes are proposed: C. major (Penard, 1891) n. comb. (Syn.: C. margaritacea var. major (Penard, 1891) and C. amphoralis (Wailes & Penard, 1911) n. comb. (Syn.: C. trochus var. amphoralis (Wailes & Penard, 1911)). However, we also show significant morphological variability between the Swiss and Bulgarian populations of C. ampulla, suggesting the possible existence of more than one taxon within this species. Further studies are required to assess (1) if these two morphologically different taxa represent individual species, (2) if so, if more species exist, and if this diversity is due to limited distribution ranges (endemism) or if several closely related taxa occur together in different geographical areas.

  15. Anterior segment biometry with 2 imaging technologies: very-high-frequency ultrasound scanning versus optical coherence tomography.

    PubMed

    Piñero, David P; Plaza, Ana Belén; Alió, Jorge L

    2008-01-01

    To determine the interchangeability of 2 anterior segment imaging systems: a very-high-frequency (VHF) ultrasound scanning system (Artemis 2, Ultralink LLC) and an optical coherence tomography (OCT) system (Visante, Zeiss). Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. This study comprised 20 eyes without pathology or previous surgery. The anterior chamber depth (ACD), central corneal thickness (CCT), angle-to-angle distance (ATA), and the iridocorneal angle size (IAS) at the 0-degree and 180-degree positions were measured with 2 imaging techniques: VHF ultrasound scanning and OCT. Analysis of agreement and interchangeability was performed by the Bland and Altman method. In addition, each measurement was performed 3 times consecutively to determine intrasession repeatability by means of the coefficient of variation (CV) and the intraclass correlation coefficient (ICC). No statistically significant differences were found between imaging techniques in ACD, CCT, or ATA (P>.40). The ranges of agreement were 0.20 mm, 16.11 mum, and 0.80 mm for ACD, CCT, and ATA, respectively. Regarding IAS, no statistically significant differences were found in the nasal (P = .78) or temporal (P = .63) measurements between devices. However, the range of agreement for nasal (14.3 degrees) and temporal (14.90 degrees) values was relevant, indicating the 2 techniques cannot be used interchangeably for IAS measurement. Excellent intrasession repeatability scores were obtained (CV and ICC). The Artemis 2 and the Visante OCT systems provide equivalent and repeatable measurements of the ACD, CCT, and ATA and can be used interchangeably for these purposes.

  16. Errors associated with IOLMaster biometry as a function of internal ocular dimensions.

    PubMed

    Faria-Ribeiro, Miguel; Lopes-Ferreira, Daniela; López-Gil, Norberto; Jorge, Jorge; González-Méijome, José Manuel

    2014-01-01

    To evaluate the error in the estimation of axial length (AL) with the IOLMaster partial coherence interferometry (PCI) biometer and obtain a correction factor that varies as a function of AL and crystalline lens thickness (LT). Optical simulations were produced for theoretical eyes using Zemax-EE software. Thirty-three combinations including eleven different AL (from 20mm to 30mm in 1mm steps) and three different LT (3.6mm, 4.2mm and 4.8mm) were used. Errors were obtained comparing the AL measured for a constant equivalent refractive index of 1.3549 and for the actual combinations of indices and intra-ocular dimensions of LT and AL in each model eye. In the range from 20mm to 30mm AL and 3.6-4.8mm LT, the instrument measurements yielded an error between -0.043mm and +0.089mm. Regression analyses for the three LT condition were combined in order to derive a correction factor as a function of the instrument measured AL for each combination of AL and LT in the theoretical eye. The assumption of a single "average" refractive index in the estimation of AL by the IOLMaster PCI biometer only induces very small errors in a wide range of combinations of ocular dimensions. Even so, the accurate estimation of those errors may help to improve accuracy of intra-ocular lens calculations through exact ray tracing, particularly in longer eyes and eyes with thicker or thinner crystalline lenses. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Objective measurement of accommodative biometric changes using ultrasound biomicroscopy

    PubMed Central

    Ramasubramanian, Viswanathan; Glasser, Adrian

    2015-01-01

    PURPOSE To demonstrate that ultrasound biomicroscopy (UBM) can be used for objective quantitative measurements of anterior segment accommodative changes. SETTING College of Optometry, University of Houston, Houston, Texas, USA. DESIGN Prospective cross-sectional study. METHODS Anterior segment biometric changes in response to 0 to 6.0 diopters (D) of accommodative stimuli in 1.0 D steps were measured in eyes of human subjects aged 21 to 36 years. Imaging was performed in the left eye using a 35 MHz UBM (Vumax) and an A-scan ultrasound (A-5500) while the right eye viewed the accommodative stimuli. An automated Matlab image-analysis program was developed to measure the biometry parameters from the UBM images. RESULTS The UBM-measured accommodative changes in anterior chamber depth (ACD), lens thickness, anterior lens radius of curvature, posterior lens radius of curvature, and anterior segment length were statistically significantly (P < .0001) linearly correlated with accommodative stimulus amplitudes. Standard deviations of the UBM-measured parameters were independent of the accommodative stimulus demands (ACD 0.0176 mm, lens thickness 0.0294 mm, anterior lens radius of curvature 0.3350 mm, posterior lens radius of curvature 0.1580 mm, and anterior segment length 0.0340 mm). The mean difference between the A-scan and UBM measurements was −0.070 mm for ACD and 0.166 mm for lens thickness. CONCLUSIONS Accommodating phakic eyes imaged using UBM allowed visualization of the accommodative response, and automated image analysis of the UBM images allowed reliable, objective, quantitative measurements of the accommodative intraocular biometric changes. PMID:25804579

  18. Multi-image encryption based on synchronization of chaotic lasers and iris authentication

    NASA Astrophysics Data System (ADS)

    Banerjee, Santo; Mukhopadhyay, Sumona; Rondoni, Lamberto

    2012-07-01

    A new technique of transmitting encrypted combinations of gray scaled and chromatic images using chaotic lasers derived from Maxwell-Bloch's equations has been proposed. This novel scheme utilizes the general method of solution of a set of linear equations to transmit similar sized heterogeneous images which are a combination of monochrome and chromatic images. The chaos encrypted gray scaled images are concatenated along the three color planes resulting in color images. These are then transmitted over a secure channel along with a cover image which is an iris scan. The entire cryptology is augmented with an iris-based authentication scheme. The secret messages are retrieved once the authentication is successful. The objective of our work is briefly outlined as (a) the biometric information is the iris which is encrypted before transmission, (b) the iris is used for personal identification and verifying for message integrity, (c) the information is transmitted securely which are colored images resulting from a combination of gray images, (d) each of the images transmitted are encrypted through chaos based cryptography, (e) these encrypted multiple images are then coupled with the iris through linear combination of images before being communicated over the network. The several layers of encryption together with the ergodicity and randomness of chaos render enough confusion and diffusion properties which guarantee a fool-proof approach in achieving secure communication as demonstrated by exhaustive statistical methods. The result is vital from the perspective of opening a fundamental new dimension in multiplexing and simultaneous transmission of several monochromatic and chromatic images along with biometry based authentication and cryptography.

  19. Central corneal thickness and related factors in an elderly American Chinese population.

    PubMed

    Wang, Dandan; Singh, Kuldev; Weinreb, Robert; Kempen, John; He, Mingguang; Lin, Shan

    2011-07-01

    To assess central corneal thickness and related factors in an elderly American Chinese population residing in San Francisco. Cross-sectional community based study. American Chinese aged 40 years and older were enrolled using random cluster sampling and volunteer screening in the Chinatown district of San Francisco. The following data were obtained: central corneal thickness by ultrasound pachymetry, intraocular pressure by Goldmann applanation tonometry, axial length by A-scan biometry, refractive status and corneal curvature by autorefractor. History of systemic and ocular diseases was collected via standard questionnaire. Central corneal thickness. Of 311 eligible subjects, 274 consented to study participation, and 228 phakic eyes were analyzed. Mean corneal thickness was 524.1 ± 31.1 µm, 545.5 ± 30.9 µm and 538.9 ± 31.8 µm in the sampling cluster, volunteer group and all subjects, respectively. A multiple linear regression model showed corneal thickness to be negatively associated with age (standardized regression coefficient [SRC] = -0.21; P = 0.016) and corneal curvature (SRC = -0.19; P = 0.018) but positively correlated with intraocular pressure (SRC = 0.20; P = 0.023). The distribution of central corneal thickness among this American Chinese population is similar to that reported in studies from East Asia. The independent factors associated with thinner corneas included older age, lower intraocular pressure and greater corneal curvature. While descendents of Chinese immigrants in America have, on average, thicker corneas than their ancestors, this phenomenon is potentially impacted by the level of intraocular pressure. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  20. Methodology of the Singapore Indian Chinese Cohort (SICC) eye study: quantifying ethnic variations in the epidemiology of eye diseases in Asians.

    PubMed

    Lavanya, Raghavan; Jeganathan, V Swetha E; Zheng, Yingfeng; Raju, Prema; Cheung, Ning; Tai, E Shyong; Wang, Jie Jin; Lamoureux, Ecosse; Mitchell, Paul; Young, Terri L; Cajucom-Uy, Howard; Foster, Paul J; Aung, Tin; Saw, Seang Mei; Wong, Tien Y

    2009-01-01

    Current knowledge of ethnic variability in the epidemiology of major eye diseases in Asia is limited. This report summarizes the rationale and study design of the Singapore Indian Chinese Cohort (SICC) Eye Study, a population-based study of ethnic South Asian (Indians) and East Asian (Chinese) older adults in Singapore. The SICC examined a population-based cross-sectional sample of 3,300 ethnic Indians and 3,300 ethnic Chinese aged 40-80+ years residing in the South-Western part of Singapore. From two lists of 12,000 names of each ethnic group provided by the Ministry of Home Affairs, age-stratified random sampling was used to select 6,350 names in each group, with a target sample size of 3,300. Invitations were sent to attend a central clinic using letters, telephone calls and home visits. Examination procedures included interviews, measurement of blood pressure, anthropometry, presenting and best-corrected visual acuity, subjective refraction, ocular biometry, Goldmann applanation tonometry, slit-lamp biomicroscopy, optic disc imaging and digital photography of the lens and retina, using a standardized protocol. Selected participants underwent gonioscopic examination, visual field testing, and anterior and posterior segment optical coherence tomography. Blood, tear, and urine samples were collected for biochemical analyses, and stored for genetic and proteomic studies. In conjunction with the Singapore Malay Eye Study, the SICC study will permit an in-depth evaluation of the prevalence, risk factors, and impact of major eye diseases in Chinese, Indians and Malays, three distinct Asian ethnic groups, whose combined numbers represent half the world's population.

  1. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity

    PubMed Central

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-01-01

    Purpose: Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Methods: Cross sectional study. Children (<16 years) enrolled from January 2014 to December 2014 with a history of laser treatment for ROP and examined for refractive and biometric status. Results: Thirty-six children presenting to us at the mean age of 7.37 ± 3.07 years (6–15 years) were included. Mean spherical equivalent (SE) was −4.05 D ± 5.10. 75% were myopic, with high astigmatism in 31%. Higher lens thickness (P = 0.03) and higher SE (P = 0.002) at 1 year postnatal age were predictors of larger SE. 79.4% achieved a favorable functional outcome (visual acuity ≥20/40). 5.88% achieved unsatisfactory outcome (<20/200) despite having a favorable structural outcome. Conclusion: There are a substantial number of children who develop myopia and high astigmatism while undergoing laser treatment for ROP. We found myopia in our cohort to be lenticular and greater axial length contributing to the development of high myopia. An initial large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low. PMID:28905827

  2. Resolution enhancement of partial coherence interferometry by dispersion compensation

    NASA Astrophysics Data System (ADS)

    Baumgartner, Angela; Hitzenberger, Christoph K.; Drexler, Wolfgang; Fercher, Adolf F.

    1997-12-01

    In the past ten years partial coherence interferometry and optical coherence tomography have been developed for high precision biometry and tomography of the human eye in vivo. The longitudinal resolution of the optical coherence tomography technique depends on the spectral bandwidth of the light source used and on the dispersion of the media to be measured. In nondispersive media the resolution is approximately equal to the coherence length of the light used, which is inversely proportional to the width of the emission spectrum. Hence, a broad emission spectrum yields a short coherence length and consequently a good resolution. However, if the tissue under investigation is dispersive, the coherence envelope of the signal broadens leading to a decrease in resolution and interference fringe contrast. This effect becomes predominant if measurements through the dispersive media of the eye to the retina are performed with source bandwidths larger than approximately 25 nm. In order to achieve optimum resolution of OCT by applying a light source with a broad emission spectrum, the dispersion of the object to be measured, i.e. in this case of the ocular media, has to be compensated. Within the scope of this work we demonstrate the resolution improvement that is obtained by compensating the dispersive effects of the ocular media and using broadband light sources. Furthermore, we present the first optical coherence tomogram recorded with this technique in the retina of a human eye in vivo with an axial geometrical resolution of approximately 6 micrometers which is a two-fold improvement compared to presently used technology.

  3. Relation of anthropometric measurements to ocular biometric changes and refractive error in children with thalassemia.

    PubMed

    Elkitkat, Rania S; El-Shazly, Amany A; Ebeid, Weam M; Deghedy, Marwa R

    2018-03-01

    To evaluate and correlate anthropometric, biometric, and refractive error changes in thalassemia major (TM). One hundred children with TM and another hundred healthy controls were recruited. Height, weight, body mass index (BMI), and occipitofrontal circumference (OFC) were the anthropometric parameters recorded. Full ophthalmologic examination was performed, including best-corrected visual acuity, cycloplegic refraction, slit-lamp examination, Goldmann applanation tonometry, indirect ophthalmoscopy, keratometry (K readings), and ocular biometry. Compared to controls, children with TM were shorter and lighter, with a smaller BMI (p<0.001); however, no significant difference existed in OFC. Regarding ocular biometric data, patients with thalassemia had steeper mean K readings (p = 0.03), shorter axial length (AXL) (p = 0.005), shorter vitreous chamber depth (p<0.001), and thicker crystalline lens (p<0.001) than controls. Patients with thalassemia had a significant myopic shift (p = 0.003). Multiple regression analyses only showed a significant correlation between corneal astigmatism and both weight and height (β = -0.05 and p = 0.03 and β = 0.06 and p = 0.04, respectively). Spherical equivalent was significantly correlated to K readings, lens thickness, and anterior chamber depth (p<0.0001 for all parameters). Compared to controls, children with TM have significant retardation in general and ocular growth (smaller BMI and shorter AXL). Ocular growth changes probably resulted in compensatory biometric changes (steeper corneas and thicker lenses) to reach emmetropization, with an exaggerated response and subsequent myopic shift. However, growth retardation is not directly related to ocular growth changes, myopic shift, or variations in biometric parameters.

  4. Failure Modes and Effects Analysis of bilateral same-day cataract surgery

    PubMed Central

    Shorstein, Neal H.; Lucido, Carol; Carolan, James; Liu, Liyan; Slean, Geraldine; Herrinton, Lisa J.

    2017-01-01

    PURPOSE To systematically analyze potential process failures related to bilateral same-day cataract surgery toward the goal of improving patient safety. SETTING Twenty-one Kaiser Permanente surgery centers, Northern California, USA. DESIGN Retrospective cohort study. METHODS Quality experts performed a Failure Modes and Effects Analysis (FMEA) that included an evaluation of sterile processing, pharmaceuticals, perioperative clinic and surgical center visits, and biometry. Potential failures in human factors and communication (modes) were identified. Rates of endophthalmitis, toxic anterior segment syndrome (TASS), and unintended intraocular lens (IOL) implantation were assessed in eyes having bilateral same-day surgery from 2010 through 2014. RESULTS The study comprised 4754 eyes. The analysis identified 15 significant potential failure modes. These included lapses in instrument processing and compounding error of intracameral antibiotic that could lead to endophthalmitis or TASS and ambiguous documentation of IOL selection by surgeons, which could lead to unintended IOL implantation. Of the study sample, 1 eye developed endophthalmitis, 1 eye had unintended IOL implantation (rates, 2 per 10 000; 95% confidence intervals [CI] 0.1–12.0 per 10 000), and no eyes developed TASS (upper 95% CI, 8 per 10 000). Recommendations included improving oversight of cleaning and sterilization practices, separating lots of compounded drugs for each eye, and enhancing IOL verification procedures. CONCLUSIONS Potential failure modes and recommended actions in bilateral same-day cataract surgery were determined using a FMEA. These findings might help improve the reliability and safety of bilateral same-day cataract surgery based on current evidence and standards. PMID:28410711

  5. Academic achievement, close up work parameters, and myopia in Singapore military conscripts

    PubMed Central

    Saw, S.; Wu, H.; Seet, B.; Wong, T.; Yap, E.; Chia, K.; Stone, R.; Lee, L.

    2001-01-01

    AIM—To determine the relation of refractive error to environmental factors, including close up work, in Singapore military conscripts.
METHODS—A cross sectional study was conducted on 429 Singapore military conscripts. Non-cycloplegic refraction and A-scan biometry were performed in both eyes. A detailed questionnaire was administered by in-person interview to obtain information about current and past near work activity, extra tuition lessons, educational experiences, and family demographics.
RESULTS—Myopia associated with the conscript having been educated in the (gifted, special, or express) educational streams (adjusted odds ratio (OR) = 3.8, 95% confidence interval CI 2.0-7.3), and having completed pre-university education (OR=4.1, 95% CI 1.9-8.8). The reported close up work activity at age 7 years did correlate with age of onset of myopia (p<0.001). In parallel, supplemental tuition lessons in primary school has (OR=2.6, 95% CI 1.4-4.9) associated with conscript myopia. Parental myopia was positively associated with myopia (p<0.001), but this relation disappeared when adjusted for environmental factors. Current (p=0.83) and past close up work activity at age 7 years (p=0.13) did not correlate with myopia.
CONCLUSION—Educational level and educational stream positively related to myopia. A relation was observed with reported close up work activity in early childhood and with tuition classes during elementary school, but not with current close up work activity. These results underscore the strong influence of environment in myopia pathogenesis but a role for close up work activity remains indeterminate.

 PMID:11423462

  6. [Evaluation of YAG-laser vitreolysis effectiveness based on quantitative characterization of vitreous floaters].

    PubMed

    Shaimova, V A; Shaimov, T B; Shaimov, R B; Galin, A Yu; Goloshchapova, Zh A; Ryzhkov, P K; Fomin, A V

    2018-01-01

    To develop methods for evaluating effectiveness of YAG-laser vitreolysis of vitreous floaters. The study included 144 patients (173 eyes) who had underwent YAG-laser vitreolysis and were under observation from 01.09.16 to 31.01.18. The patients were 34 to 86 years old (mean age 62.7±10.2 years), 28 (19.4%) patients were male, 116 (80.6%) - female. All patients underwent standard and additional examination: ultrasonography (Accutome B-scan plus, U.S.A.), optic biometry (Lenstar 900, Haag-Streit, Switzerland), spectral optical coherence tomography using RTVue XR Avanti scanner (Optovue, U.S.A.) in modes Enhanced HD Line, 3D Retina, 3D Widefield MCT, Cross Line, Angio Retina, and scanning laser ophthalmoscopy (SLO) using Navilas 577s system. Laser vitreolysis was performed using the Ultra Q Reflex laser (Ellex, Australia). This paper presents methods of objective quantitative and qualitative assessment of artifactual shadows of vitreous floaters with spectral optical coherence tomographic scanner RTVue xR Avanti employing an algorithm of automatic detection of non-perfusion zones in modes Angio Retina, HD Angio Retina, as well as foveal avascular zone (FAZ) measurement with Angio Analytics® software. SLO performed with Navilas 577s was used as method of visualizing floaters and artifactual shadows in retinal surface layers prior to surgical treatment and after YAG-laser vitreolysis. Suggested methods of quantitative and qualitative assessment of artifactual shadows of the floaters in retinal layers are promising and may prove to be highly relevant for clinical monitoring of patients, optimization of treatment indications and evaluating effectiveness of YAG-laser vitreolysis. Further research of laser vitreolysis effectiveness in patients with vitreous floaters is necessary.

  7. Implications of nutritional stress as nestling or fledgling on subsequent attractiveness and fecundity in zebra finches (Taeniopygia guttata).

    PubMed

    Honarmand, Mariam; Krause, E Tobias; Naguib, Marc

    2017-01-01

    The conditions an organism experiences during early development can have profound and long lasting effects on its subsequent behavior, attractiveness, and life history decisions. Most previous studies have exposed individuals to different conditions throughout development until nutritional independence. Yet under natural conditions, individuals may experience limitations for much shorter periods due to transient environmental fluctuations. Here, we used zebra finches ( Taeniopygia guttata ) in captivity to determine if conditions experienced during distinctly different early developmental phases contribute differently to male and female attractiveness and subsequent reproduction. We conducted a breeding experiment in which offspring were exposed to food regimes with (a) low quality food provided only during the nestling period, (b) low quality food provided only during the fledgling period, or (c) high quality food throughout early development. We show that despite short-term effects on biometry and physiology, there were no effects on either male or female attractiveness, as tested in two-way mate choice free-flight aviary experiments. In a subsequent breeding experiment, the offspring from the initial experiment were allowed to breed themselves. The next generation offspring from mothers raised under lower quality nutrition as either nestling or fledging were lighter at hatching compared to offspring from mothers raised under higher quality nutrition whereas paternal early nutrition had no such effects. The lack of early developmental limitations on attractiveness suggests that attractiveness traits were not affected or that birds compensated for any such effects. Furthermore, maternal trans-generational effects of dietary restrictions emphasize the importance of role of limited periods of early developmental stress in the expression of environmentally determined fitness components.

  8. Changes in Doppler flow velocity waveforms and fetal size at 20 weeks gestation among cigarette smokers.

    PubMed

    Kho, E M; North, R A; Chan, E; Stone, P R; Dekker, G A; McCowan, L M E

    2009-09-01

    To compare umbilical and uterine artery Doppler waveforms and fetal size at 20 weeks between smokers and nonsmokers. Prospective cohort study. Auckland, New Zealand and Adelaide, Australia. Nulliparous participants in the Screening for Pregnancy Endpoints (SCOPE) study. Self-reported smoking status was determined at 15 +/- 1 weeks' gestation. At the 20 +/- 1 week anatomy scan, uterine and umbilical Doppler resistance indices (RI) and fetal measurements were compared between smokers and nonsmokers. Umbilical and mean uterine artery Doppler RI values, abnormal umbilical and uterine Doppler (RI > 90th centile) and fetal biometry. Among the 2459 women, 248 (10%) were smokers. Smokers had higher umbilical RI [0.75 (SD 0.06) versus 0.73 (0.06), P < 0.0001] and mean uterine RI [0.59 (0.09) versus 0.56 (0.10), P < 0.0001]. They were twice as likely to have an abnormal umbilical Doppler at 20 weeks compared with nonsmokers [n = 35 (14.6%) versus n = 156 (7.2%), OR 2.21, 95% CI 1.49-3.27]. This effect remained significant after adjusting for age, ethnicity, marital status, employment and BMI (adjusted OR 1.62, 95% CI 1.03-2.54). Smokers were more likely to have an abnormal mean uterine RI [n = 33 (13.7%) versus n = 198 (9.2%), OR 1.57, 95% CI 1.06-2.33], but this association was not significant after adjusting for confounders. Fetuses of women who smoked had a small reduction in femur length and estimated weight compared with nonsmokers. At 20 weeks' gestation, women who smoke have higher umbilical artery RI, a surrogate measure for an abnormal placental villous vascular tree. This may contribute to later fetal growth restriction among smokers. Further research is needed to explore the clinical significance of these findings.

  9. Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens design.

    PubMed

    Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando

    2018-01-01

    To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP ® ) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof ® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820 ® ). YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 ( p =0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm ( p =0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm ( p =0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups ( p >0.05). YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant.

  10. The Royal College of Ophthalmologists' National Ophthalmology Database Study of cataract surgery: report 2, relationships of axial length with ocular copathology, preoperative visual acuity, and posterior capsule rupture

    PubMed Central

    Day, A C; Donachie, P H J; Sparrow, J M; Johnston, R L

    2015-01-01

    Purpose To describe the relationships of axial length with ocular copathology, preoperative visual acuity, and posterior capsule rupture rates in patients undergoing cataract surgery. Design The Royal College of Ophthalmologists' National Ophthalmology Database (NOD) study. Methods Anonymised data on 180 114 eyes from 127 685 patients undergoing cataract surgery between August 2006 and November 2010 were collected prospectively from 28 sites. Data parameters included: demographics, biometry, ocular copathology, visual acuity measurements, and surgical complications including posterior capsule rupture, or vitreous loss or both (PCR). Results Consultant surgeons performed a higher proportion of operations on eyes whose axial length were at the extremes. Glaucoma and age related macular degeneration were more common in eyes with shorter axial lengths, whilst previous vitrectomy was associated with longer axial lengths. Eyes with brunescent or white cataracts or amblyopia were more common at both axial length extremes. Preoperative visual acuities were similar for eyes with axial length measurements up to approximately 28 mm and worse for eyes with longer axial length measurements. PCR rates showed little change with axial length (overall mean 1.95%, 95% CI: 1.89 to 2.01%), except for a borderline increase in eyes with axial length <20.0 mm where rates were 3.6% (95% CI: 2.0 to 6.3%). The likelihood of PCR in eyes with axial length <20.0 mm was 1.88 times higher than those of ≥20.0 mm (P=0.0373). Conclusion Rates of ocular comorbidities vary by axial length. PCR rates in eyes with very short or long axial lengths were lower than expected. PMID:26493034

  11. Changes in corneal biometry and the associated histology in rhesus monkeys wearing orthokeratology contact lenses.

    PubMed

    Ding, Hui; Pu, Aijun; He, Hong; Xie, Ruo Zhong; Yang, Jun; Liao, Aiping; Gao, Shaohui; Zhong, Xingwu

    2012-08-01

    This study compared the effect of orthokeratology (OK) lens wear on corneal topography and microstructure between the 1-night and 30-night wearers to predict any adverse responses of the eyes to long-term OK lens wear. Nine rhesus monkeys with one eye wearing an OK lens and the fellow eye wearing a rigid gas permeable (RGP) lens were used in this study. The lenses were worn for 11 hours, with the measurement of corneal curvature and thickness and axial components of the eye at 0 night (n = 9), 1 night (n = 9), and 30 nights (n = 6). Histology was performed at 1 and 30 nights of lens wear. Corneal surface power in the 3-mm central region was reduced in the OK eye when compared with the RGP eye (P < 0.05). Central corneal thickness was only reduced in 30 nights of OK lens wear (P < 0.05). Under light microscopy, the 1-night OK or RGP eyes showed normal morphology in all layers of the cornea. The 30-night OK eyes showed a thinned central corneal epithelium and a thickened but less stratified paracentral corneal epithelium when compared with the 30-night RGP eyes. Under electron microscopy, intercellular junctions of corneal epithelium in the 30-night OK eyes were much looser than those in the 1-night OK eyes. However, the density and morphology of hemidesmosomes were similar between the OK and RGP eyes at 30 nights of lens wear. Overnight OK can change the corneal curvature through anterior corneal remodeling, resulting in an effective correction of myopia. However, a decrease in intercellular junctions during long-term wear may compromise the functions of the corneal epithelium as a border mechanical barrier.

  12. New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism.

    PubMed

    Canovas, Carmen; Alarcon, Aixa; Rosén, Robert; Kasthurirangan, Sanjeev; Ma, Joseph J K; Koch, Douglas D; Piers, Patricia

    2018-02-01

    To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Abbott Medical Optics, Inc., Groningen, the Netherlands. Retrospective case report. In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon-estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism (P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against-the-rule, with-the-rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups (P < .001). The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism.

    PubMed

    Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina

    2017-10-01

    To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 20/32 with +8.00/-4.50×30° for the right eye (RE) and 20/25 with +7.75/-2.25×120° for the left eye (LE). After CScL fitting, visual acuity was improved to 20/20 and 20/16 for the RE and LE, respectively. The patient wore these contact lenses an average of 13h a day. The total high order aberrations decreased by approximately 79% in the RE (2.37-0.50μm) and 47% in the LE (1.04-0.55μm) after CScL fitting. Visual quality and wearing time were maintained after 1year wearing CScL. In addition, no adverse ocular effects were found during this period. The present case report describes how the patient had CScL fitted successfully for management of keratoconus with high hyperopia and astigmatism. They provided optimal visual quality, along with prolonged use times and no adverse effects to the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Growth perturbations in a phenotype with rapid fetal growth preceding preterm labor and term birth.

    PubMed

    Lampl, Michelle; Kusanovic, Juan Pedro; Erez, Offer; Gotsch, Francesca; Espinoza, Jimmy; Goncalves, Luis; Lee, Wesley; Gomez, Ricardo; Nien, Jyh Kae; Frongillo, Edward A; Romero, Roberto

    2009-01-01

    The variability in fetal growth rates and gestation duration in humans is not well understood. Of interest are women presenting with an episode of preterm labor and subsequently delivering a term neonate, who is small relative to peers of similar gestational age. To further understand these relationships, fetal growth patterns predating an episode of preterm labor were investigated. Retrospective analysis of fetal biometry assessed by serial ultrasound in a prospectively studied sample of pregnancies in Santiago, Chile, tested the hypothesis that fetal growth patterns among uncomplicated pregnancies (n = 3,706) and those with an episode of preterm labor followed by term delivery (n = 184) were identical across the time intervals 16-22 weeks, 22-28 weeks, and 28-34 weeks in a multilevel mixed-effects regression. The hypothesis was not supported. Fetal weight growth rate was faster from 16 weeks among pregnancies with an episode of preterm labor (P < 0.05), declined across midgestation (22-28 weeks, P < 0.05), and rebounded between 28 and 34 weeks (P = 0.06). This was associated with perturbations in abdominal circumference growth and proportionately larger biparietal diameter from 22 gestational weeks (P = 0.03), greater femur (P = 0.01), biparietal diameter (P = 0.001) and head circumference (P = 0.02) dimensions relative to abdominal circumference across midgestation (22-28 weeks), followed by proportionately smaller femur diaphyseal length (P = 0.02) and biparietal diameter (P = 0.03) subsequently. A distinctive rapid growth phenotype characterized fetal growth preceding an episode of preterm labor among this sample of term-delivered neonates. Perturbations in abdominal circumference growth and patterns of proportionality suggest an altered growth strategy pre-dating the preterm labor episode.

  15. Food and Drug Administration study update. One-year results from 671 patients with the 3M multifocal intraocular lens.

    PubMed

    Lindstrom, R L

    1993-01-01

    The clinical evaluation of the Food and Drug Administration study of the 3M diffractive multifocal intraocular lens (IOL) is presented here to demonstrate the results of 1-year postoperative data accumulated for 671 patients, the first of whom received the implant in 1987. Patients were selected for study if they had absence of preoperative pathology, were at least 60 years of age, and had a reasonable postoperative prognosis. Extensive evaluations took place at 4 to 6 months and 12 to 14 months after surgery, including five different visual acuity measurements and contrast sensitivity. All testing was completed on both eyes. Data from the fellow eye served as a control when implanted with a monofocal IOL. Overall uncorrected distance visual acuity at 1 year after surgery shows 57% patients with 20/40 or better acuity. In this same group, 78% achieved J3 or better near vision, which improved to 82% in the best case group. Uncorrected visual acuity of 20/40 or better and J3 or better was achieved by 50% of best case multifocal IOL patients, compared with 26% of the monofocal best case comparison group. Measurements of contrast sensitivity consistently document a small loss, which is considered clinically insignificant. Statistical analysis of satisfaction ratings shows that predictors of satisfaction include uncorrected distance acuity, final near acuity, and fellow eye spherical equivalent. This multifocal lens appears to work very well for most patients, with more than half having functional uncorrected distance and near vision. The study showed several considerations that are important for optimizing clinical performance and patient satisfaction: patient selection, realistic expectations, accurate biometry, and adequate control of surgical procedures.

  16. Reduced Scleral TIMP-2 Expression Is Associated With Myopia Development: TIMP-2 Supplementation Stabilizes Scleral Biomarkers of Myopia and Limits Myopia Development.

    PubMed

    Liu, Hsin-Hua; Kenning, Megan S; Jobling, Andrew I; McBrien, Neville A; Gentle, Alex

    2017-04-01

    The purpose of this study was to determine the endogenous regulation pattern of tissue inhibitor of metalloproteinase-2 (TIMP-2) in the tree shrew sclera during myopia development and investigate the capacity of exogenous TIMP-2 to inhibit matrix metalloproteinase-2 (MMP-2) in vitro and both scleral collagen degradation and myopia development in vivo. TIMP-2 expression in the sclera during myopia development was assessed using polymerase chain reaction. In vitro TIMP-2 inhibition of MMP-2 was investigated using a gelatinase activity plate assay and zymography. Tree shrews were injected with a collagen precursor before undergoing monocular form deprivation and concurrent daily subconjunctival injections of either TIMP-2 or vehicle to the form-deprived eye. In vivo ocular biometry changes were monitored, and scleral tissue was collected after 12 days and assayed for collagen degradation. The development of myopia was associated with a mean reduction in TIMP-2 mRNA expression after 5 days of form deprivation (P < 0.01). Both activation and activity of MMP-2 were inhibited by TIMP-2 with an IC50 of 10 to 20 and 2 nM, respectively. In vivo exogenous addition of TIMP-2 significantly reduced myopia development (P < 0.01), due to reduced vitreous chamber elongation (P < 0.01). In vivo TIMP-2 treatment also significantly inhibited posterior scleral collagen degradation relative to vehicle-treated eyes (P < 0.01), with levels similar to those in control eyes. Myopia development in mammals is associated with reduced expression of TIMP-2, which contributes to increased degradative activity in the sclera. It follows that replenishment of this TIMP-2 significantly reduced the rate of both scleral collagen degradation and myopia development.

  17. Zika virus detected in amniotic fluid and umbilical cord blood in an in vitro fertilization-conceived pregnancy in Venezuela.

    PubMed

    Benjamin, Isaac; Fernández, Gissel; Figueira, José Valentin; Parpacén, Leticia; Urbina, María Teresa; Medina, Randolfo

    2017-06-01

    To describe the consequences of Zika virus infection at 10 weeks of gestation in an IVF-conceived pregnancy in Venezuela. A case report. Private assisted reproduction unit. A 36-year-old patient who conceived her first pregnancy through IVF and became infected with Zika virus at 10 weeks' gestation in Venezuela. In vitro fertilization with fresh ET. Clinical, laboratory, and imaging Zika diagnostic methods. Zika virus detection by real-time polymerase chain reaction (PCR) in maternal plasma, PCR in amniotic fluid and umbilical cord blood. Ultrasonography findings of anatomic abnormalities. Zika infection was confirmed at 10 weeks' gestation by real-time PCR; ultrasound results appeared normal. At 19 weeks' gestation, an ultrasound revealed biometry on three SDs below the means for all parameters but with no apparent anatomic abnormality. Zika virus was positive in maternal urine and amniotic fluid by PCR at 19 weeks' gestation. Ultrasound at 21 weeks + 4 days of gestation showed fetal cerebellar hypoplasia with ventricular dysmorphia, particularly marked on the left, consistent with microcephaly and ventriculomegaly. Because of the poor prognosis, pregnancy was interrupted at 24 weeks' gestation, in France. The PCR in umbilical cord blood taken in this procedure was positive for Zika virus. Initial ultrasound findings in pregnancy may not be informative. Only at 21 weeks + 4 days of gestation did an ultrasound reveal fetal microcephaly and ventriculomegaly. Combined clinical, laboratory, and imaging findings provided a complete picture of the severe damage caused by Zika infection. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    PubMed

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  19. Antenatal risk factors associated with neonatal morbidity in large for gestational age infants: an international prospective cohort study.

    PubMed

    Vieira, Matias C; McCowan, Lesley Me; North, Robyn A; Myers, Jenny E; Walker, James J; Baker, Philip N; Dekker, Gustaaf A; Kenny, Louise C; Poston, Lucilla; Pasupathy, Dharmintra

    2018-05-12

    Large for gestational age (LGA) infants are associated with increased risk of neonatal morbidity and mortality, however most of them will not have adverse outcomes. Our aim was to identify antenatal clinical factors associated with neonatal morbidity in LGA infants. Nulliparous women from the Screening for Pregnancy Endpoints (SCOPE) study were included. We compared maternal and fetal factors between LGA infants (birthweight >90 th customized centile) with and without neonatal morbidity, defined as admission to neonatal intensive care unit or severe neonatal morbidity. Factors were selected based on a-priori hypotheses of association and included maternal demography, anthropometric measures and self-reported physical activity (15 and 20 weeks), fetal biometry (20 weeks), and clinical information. Multivariable logistic regression was used to identify risk factors. Stratified analyses were performed by maternal obesity and physical activity. Amongst term pregnancies, prevalence of LGA infants was 9.3% (491/5,255), with 11.8% (58/491) prevalence of neonatal morbidity. Random glucose at 20 weeks (OR 1.52; 95% CI1.17 to 1.97, per 1mmol/L increase) and no regular physical activity at 20 weeks (3.93; 1.75 to 8.83) were associated with increased risk of neonatal morbidity after adjustment for birthweight, gestational age at delivery and gestational diabetes. The increased risk associated with higher glucose levels was not evident in women with regular physical activity or without obesity. Regular physical activity in mid-pregnancy is associated with lower risk for neonatal morbidity in LGA infants and seems to offer protection against the increased risk associated with higher maternal glucose levels. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Light Exposure and Eye Growth in Childhood.

    PubMed

    Read, Scott A; Collins, Michael J; Vincent, Stephen J

    2015-10-01

    The purpose of this study was to examine the relationship between objectively measured ambient light exposure and longitudinal changes in axial eye growth in childhood. A total of 101 children (41 myopes and 60 nonmyopes), 10 to 15 years of age participated in this prospective longitudinal observational study. Axial eye growth was determined from measurements of ocular optical biometry collected at four study visits over an 18-month period. Each child's mean daily light exposure was derived from two periods (each 14 days long) of objective light exposure measurements from a wrist-worn light sensor. Over the 18-month study period, a modest but statistically significant association between greater average daily light exposure and slower axial eye growth was observed (P = 0.047). Other significant predictors of axial eye growth in this population included children's refractive error group (P < 0.001), sex (P < 0.01), and age (P < 0.001). Categorized according to their objectively measured average daily light exposure and adjusting for potential confounders (age, sex, baseline axial length, parental myopia, nearwork, and physical activity), children experiencing low average daily light exposure (mean daily light exposure: 459 ± 117 lux, annual eye growth: 0.13 mm/y) exhibited significantly greater eye growth than children experiencing moderate (842 ± 109 lux, 0.060 mm/y), and high (1455 ± 317 lux, 0.065 mm/y) average daily light exposure levels (P = 0.01). In this population of children, greater daily light exposure was associated with less axial eye growth over an 18-month period. These findings support the role of light exposure in the documented association between time spent outdoors and childhood myopia.

  1. Digitization of the human body in the present-day economy

    NASA Astrophysics Data System (ADS)

    D'Apuzzo, Nicola

    2004-12-01

    In this paper we report on the historic development of human body digitization and on the actual state of commercially available technology. Complete systems for the digitization of the human body exist since more than ten years. One of the main users of this technology was the entertainment industry. Every new movie excited with attractive visual effects, but only few people knew that the most thrilling cuts were realized by using virtual persons. The faces and bodies of actors were digitized and the "virtual twin" replaced the actor in the movie. Nowadays, the state of the human body digitization is so high that it is not possible any more to distinguish the real actor from the virtual one. Indeed, for the rush technical development has to be thanked the movie industry, which was one of the strong economic motors for this technology. Today, with the possibility of a massive cost reduction given by new technologies, methods for digitization of the human body are used also in other fields of application, such as ergonomics, medical applications, computer games, biometry and anthropometrics. With the time, this technology becomes interesting also for sport, fitness, fashion and beauty. A large expansion of human body digitization is expected in the near future. To date, different technologies are used commercially for the measurement of the human body. They can be divided into three distinguished groups: laser-scanning, projection of light patterns, combination modeling and image processing. The different solutions have strengths and weaknesses that profile their suitability for specific applications. This paper gives an overview of their differences and characteristics and expresses clues for the selection of the adequate method. Practical examples of commercial exploitation of human body digitization are also presented and new interesting perspectives are introduced.

  2. Five-year change in refraction and its ocular components in the 40- to 64-year-old population of the Shahroud eye cohort study.

    PubMed

    Hashemi, Hassan; Khabazkhoob, Mehdi; Iribarren, Rafael; Emamian, Mohammad Hassan; Fotouhi, Akbar

    2016-11-01

    To assess 5-year refractive changes and their related factors in the 40- to 64-year-old population of Shahroud, Iran. Prospective cohort study. Of the 5190 participants of Phase I, 4737 participated in Phase II (response rate = 91.3%). Participants were tested by refraction, visual acuity, slit-lamp biomicroscopy, ophthalmoscopy and biometry. Myopia was defined as a spherical equivalent more negative than -0.5 dioptre (D) and hyperopia as a spherical equivalent more positive than +0.5 D. Mean 5-year change in spherical equivalent refraction. The mean 5-year change in spherical equivalent refraction was +0.24 D (95% CI: +0.22 to +0.25). After 5 years, 4.77% (95% CI: 4.08 to 5.46) of subjects developed at least 0.5 D of myopia and 22.27% (95% CI: 20.97 to 23.57) developed at least 0.5 D of hyperopia. Five-year changes in refraction included a hyperopic shift in all age groups. The greatest hyperopic shift was seen in middle-aged women. The greatest loss of lens power was observed in hyperopic women and the least in myopic men. Nuclear cataract was associated with a myopic shift in refraction. The axial length and the corneal power had very small changes during this period. Myopes showed the greatest increase in axial length. Corneal power increased by a very small amount in all refractive groups. The most important biometric index related to hyperopic shifts, which were greater in magnitude in women, was loss of lens power, whereas nuclear cataract was associated with myopic shifts. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  3. Embryonic and fetal morphology in the lowland paca (Cuniculus paca): A precocial hystricomorph rodent.

    PubMed

    El Bizri, Hani Rocha; Monteiro, Frederico Ozanan Barros; de Andrade, Rafael Dos Santos; Valsecchi, João; Guimarães, Diva Anelie de Araújo; Mayor, Pedro

    2017-12-01

    In mammals, the embryonic and fetal development of a species has evolved to maximize neonatal survival. In this study, we use a sample of 132 embryos/fetuses of wild lowland paca (Cuniculus paca), obtained over a period of 15 years through collaborative methods with local hunters in the Amazon to describe the intrauterine development of external and internal morphology of this Neotropical rodent. We also compare the newborn survival strategy in this species with other rodents. The crown-rump length (CRL) ranged between 0.6 and 24.6 cm. External features appeared in the following chronological order: limbs, eyelid buds, fusioned eyelids, genitalia, outer ear, tactile pelage, claws, skin, skin spots, covering pelage, teeth and open eyelids. Fetuses with CRL >19.5 cm presented all external features fully developed. The growth formula of fetal age was calculated as ∛W = 0.082 (t - 37.25), and age was accurately associated with CRL. We described the relationship between CRL and external and internal biometry. The liver declined in proportion within the internal cavity, while the relative volume of tubular gastrointestinal organs increased significantly along the embryo/fetal development. All organs, except the heart and the thymus, had similar relative volumes in advanced fetuses and adults. Our comparison of the intrauterine development in several rodent species indicates that the paca's reproductive strategy is comparable to species that are subject to low natural predation. Given that C. paca is perhaps the most hunted animal in Latin America, sustainable hunting throughout its range must take into account its relative reproductive performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Ultrasonographic Fetal Weight Estimation: Should Macrosomia-Specific Formulas Be Utilized?

    PubMed

    Porter, Blake; Neely, Cherry; Szychowski, Jeff; Owen, John

    2015-08-01

    This study aims to derive an estimated fetal weight (EFW) formula in macrosomic fetuses, compare its accuracy to the 1986 Hadlock IV formula, and assess whether including maternal diabetes (MDM) improves estimation. Retrospective review of nonanomalous live-born singletons with birth weight (BWT) ≥ 4 kg and biometry within 14 days of birth. Formula accuracy included: (1) mean error (ME = EFW - BWT), (2) absolute mean error (AME = absolute value of [1]), and (3) mean percent error (MPE, [1]/BWT × 100%). Using loge BWT as the dependent variable, multivariable linear regression produced a macrosomic-specific formula in a "training" dataset which was verified by "validation" data. Formulas specific for MDM were also developed. Out of the 403 pregnancies, birth gestational age was 39.5 ± 1.4 weeks, and median BWT was 4,240 g. The macrosomic formula from the training data (n = 201) had associated ME = 54 ± 284 g, AME = 234 ± 167 g, and MPE = 1.6 ± 6.2%; evaluation in the validation dataset (n = 202) showed similar errors. The Hadlock formula had associated ME = -369 ± 422 g, AME = 451 ± 332 g, MPE = -8.3 ± 9.3% (all p < 0.0001). Diabetes-specific formula errors were similar to the macrosomic formula errors (all p = NS). With BWT ≥ 4 kg, the macrosomic formula was significantly more accurate than Hadlock IV, which systematically underestimates fetal/BWT. Diabetes-specific formulas did not improve accuracy. A specific formula should be considered when macrosomia is suspected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Effects of maternal dexamethasone treatment on pancreatic β cell function in the pregnant mare and post natal foal.

    PubMed

    Valenzuela, O A; Jellyman, J K; Allen, V L; Holdstock, N B; Fowden, A L

    2017-01-01

    Synthetic glucocorticoids are used to treat inflammatory conditions in horses. In other pregnant animals, glucocorticoids are given to stimulate fetal maturation with long-term metabolic consequences for the offspring if given preterm. However, their metabolic effects during equine pregnancy remain unknown. Thus, this study investigated the metabolic effects of dexamethasone administration on pregnant pony mares and their foals after birth. Experimental study. A total of 3 doses of dexamethasone (200 μg/kg bwt i.m.) were given to 6 pony mares at 48 h intervals beginning at ≈270 days of pregnancy. Control saline injections were given to 5 mares using the same protocol. After fasting overnight, pancreatic β cell responses to exogenous glucose were measured in the mares before, during and after treatment. After birth, pancreatic β cell responses to exogenous glucose and arginine were measured in the foals at 2 and 12 weeks. In mares during treatment, dexamethasone but not saline increased basal insulin concentrations and prolonged the insulin response to exogenous glucose. Basal insulin and glucose concentrations still differed significantly between the 2 groups 72 h post treatment. Dexamethasone treatment significantly reduced placental area but had little effect on foal biometry at birth or subsequently. Foal β cell function at 2 weeks was unaffected by maternal treatment. However, by 12 weeks, pancreatic β cell sensitivity to arginine, but not glucose, was less in foals delivered by dexamethasone- than saline-treated mares. Dexamethasone administration induced changes in maternal insulin-glucose dynamics, indicative of insulin resistance and had subtle longer term effects on post natal β cell function of the foals. The programming effects of dexamethasone in horses may be mediated partially by altered maternal metabolism and placental growth. © 2016 EVJ Ltd.

  6. Intraocular lens power selection and positioning with and without intraoperative aberrometry.

    PubMed

    Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H

    2015-04-01

    To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.

  7. Postnatal Anthropometric and Body Composition Profiles in Infants with Intrauterine Growth Restriction Identified by Prenatal Doppler

    PubMed Central

    Mazarico, E.; Martinez-Cumplido, R.; Díaz, M.; Sebastiani, G.; Ibáñez, L.; Gómez-Roig, M. D.

    2016-01-01

    Introduction Infant anthropometry and body composition have been previously assessed to gauge the impact of intrauterine growth restriction (IUGR) at birth, but the interplay between prenatal Doppler measurements and postnatal development has not been studied in this setting. The present investigation was performed to assess the significance of prenatal Doppler findings relative to postnatal anthropometrics and body composition in IUGR newborns over the first 12 months of life. Patients and Methods Consecutive cases of singleton pregnancies with suspected IUGR were prospectively enrolled over 12 months. Fetal biometry and prenatal Doppler ultrasound examinations were performed. Body composition was assessed by absorptiometry at ages 10 days, and at 4 and12 months. Results A total of 48 pregnancies qualifying as IUGR were studied. Doppler parameters were normal in 26 pregnancies. The remaining 22 deviated from normal, marked by an Umbilical Artery Pulsatility Index (UA-PI) >95th centil or Cerebro-placental ratio (CPR) <5th centile. No significant differences emerged when comparing anthropometry and body composition at each time point, in relation to Doppler findings. Specifically, those IUGR newborns with and without abnormal Doppler findings had similar weight, length, body mass index, lean and fat mass, and bone mineral content throughout the first 12 months of life. In a separate analysis, when comparing IUGR newborns by Doppler (abnormal UA-PI vs. abnormal CPR), anthropometry and body composition did not differ significantly. Conclusions Infants with IUGR maintain a pattern of body composition during the first year of life that is independent of prenatal Doppler findings. Future studies with larger sample sizes and correlating with hormonal status are warranted to further extend the phenotypic characterization of the various conditions now classified under the common label of IUGR. PMID:26938993

  8. Variant myopia: A new presentation?

    PubMed Central

    Hussaindeen, Jameel Rizwana; Anand, Mithra; Sivaraman, Viswanathan; Ramani, Krishna Kumar; Allen, Peter M

    2018-01-01

    Purpose: Variant myopia (VM) presents as a discrepancy of >1 diopter (D) between subjective and objective refraction, without the presence of any accommodative dysfunction. The purpose of this study is to create a clinical profile of VM. Methods: Fourteen eyes of 12 VM patients who had a discrepancy of >1D between retinoscopy and subjective acceptance under both cycloplegic and noncycloplegic conditions were included in the study. Fourteen eyes of 14 age- and refractive error-matched participants served as controls. Potential participants underwent a comprehensive orthoptic examination followed by retinoscopy (Ret), closed-field autorefractor (CA), subjective acceptance (SA), choroidal and retinal thickness, ocular biometry, and higher order spherical aberrations measurements. Results: In the VM eyes, a statistically and clinically significant difference was noted between the Ret and CA and Ret and SA under both cycloplegic and noncycloplegic conditions (multivariate repeated measures analysis of variance, P < 0.0001). A statistically significant difference was observed between the VM eyes, non-VM eyes, and controls for choroidal thickness in all the quadrants (Univariate ANOVA P < 0.05). The VM eyes had thinner choroids (197.21 ± 13.04 μ) compared to the non-VM eyes (249.25 ± 53.70 μ) and refractive error-matched controls (264.62 ± 12.53 μ). No statistically significant differences between groups in root mean square of total higher order aberrations and spherical aberration were observed. Conclusion: Accommodative etiology does not play a role in the refractive discrepancy seen in individuals with the variant myopic presentation. These individuals have thinner choroids in the eye with variant myopic presentation compared to the fellow eyes and controls. Hypotheses and clinical implications of variant myopia are discussed. PMID:29785987

  9. Reference Charts for Fetal Cerebellar Vermis Height: A Prospective Cross-Sectional Study of 10605 Fetuses

    PubMed Central

    Cignini, Pietro; Giorlandino, Maurizio; Brutti, Pierpaolo; Mangiafico, Lucia; Aloisi, Alessia; Giorlandino, Claudio

    2016-01-01

    Objective To establish reference charts for fetal cerebellar vermis height in an unselected population. Methods A prospective cross-sectional study between September 2009 and December 2014 was carried out at ALTAMEDICA Fetal–Maternal Medical Centre, Rome, Italy. Of 25203 fetal biometric measurements, 12167 (48%) measurements of the cerebellar vermis were available. After excluding 1562 (12.8%) measurements, a total of 10605 (87.2%) fetuses were considered and analyzed once only. Parametric and nonparametric quantile regression models were used for the statistical analysis. In order to evaluate the robustness of the proposed reference charts regarding various distributional assumptions on the ultrasound measurements at hand, we compared the gestational age-specific reference curves we produced through the statistical methods used. Normal mean height based on parametric and nonparametric methods were defined for each week of gestation and the regression equation expressing the height of the cerebellar vermis as a function of gestational age was calculated. Finally the correlation between dimension/gestation was measured. Results The mean height of the cerebellar vermis was 12.7mm (SD, 1.6mm; 95% confidence interval, 12.7–12.8mm). The regression equation expressing the height of the CV as a function of the gestational age was: height (mm) = -4.85+0.78 x gestational age. The correlation between dimension/gestation was expressed by the coefficient r = 0.87. Conclusion This is the first prospective cross-sectional study on fetal cerebellar vermis biometry with such a large sample size reported in literature. It is a detailed statistical survey and contains new centile-based reference charts for fetal height of cerebellar vermis measurements. PMID:26812238

  10. When do myopia genes have their effect? Comparison of genetic risks between children and adults.

    PubMed

    Tideman, J Willem L; Fan, Qiao; Polling, Jan Roelof; Guo, Xiaobo; Yazar, Seyhan; Khawaja, Anthony; Höhn, René; Lu, Yi; Jaddoe, Vincent W V; Yamashiro, Kenji; Yoshikawa, Munemitsu; Gerhold-Ay, Aslihan; Nickels, Stefan; Zeller, Tanja; He, Mingguang; Boutin, Thibaud; Bencic, Goran; Vitart, Veronique; Mackey, David A; Foster, Paul J; MacGregor, Stuart; Williams, Cathy; Saw, Seang Mei; Guggenheim, Jeremy A; Klaver, Caroline C W

    2016-12-01

    Previous studies have identified many genetic loci for refractive error and myopia. We aimed to investigate the effect of these loci on ocular biometry as a function of age in children, adolescents, and adults. The study population consisted of three age groups identified from the international CREAM consortium: 5,490 individuals aged <10 years; 5,000 aged 10-25 years; and 16,274 aged >25 years. All participants had undergone standard ophthalmic examination including measurements of axial length (AL) and corneal radius (CR). We examined the lead SNP at all 39 currently known genetic loci for refractive error identified from genome-wide association studies (GWAS), as well as a combined genetic risk score (GRS). The beta coefficient for association between SNP genotype or GRS versus AL/CR was compared across the three age groups, adjusting for age, sex, and principal components. Analyses were Bonferroni-corrected. In the age group <10 years, three loci (GJD2, CHRNG, ZIC2) were associated with AL/CR. In the age group 10-25 years, four loci (BMP2, KCNQ5, A2BP1, CACNA1D) were associated; and in adults 20 loci were associated. Association with GRS increased with age; β = 0.0016 per risk allele (P = 2 × 10 -8 ) in <10 years, 0.0033 (P = 5 × 10 -15 ) in 10- to 25-year-olds, and 0.0048 (P = 1 × 10 -72 ) in adults. Genes with strongest effects (LAMA2, GJD2) had an early effect that increased with age. Our results provide insights on the age span during which myopia genes exert their effect. These insights form the basis for understanding the mechanisms underlying high and pathological myopia. © 2016 WILEY PERIODICALS, INC.

  11. Evidence of biphonation and source-filter interactions in the bugles of male North American wapiti (Cervus canadensis).

    PubMed

    Reby, D; Wyman, M T; Frey, R; Passilongo, D; Gilbert, J; Locatelli, Y; Charlton, B D

    2016-04-15

    With an average male body mass of 320 kg, the wapiti, ITALIC! Cervus canadensis, is the largest extant species of Old World deer (Cervinae). Despite this large body size, male wapiti produce whistle-like sexual calls called bugles characterised by an extremely high fundamental frequency. Investigations of the biometry and physiology of the male wapiti's relatively large larynx have so far failed to account for the production of such a high fundamental frequency. Our examination of spectrograms of male bugles suggested that the complex harmonic structure is best explained by a dual-source model (biphonation), with one source oscillating at a mean of 145 Hz (F0) and the other oscillating independently at an average of 1426 Hz (G0). A combination of anatomical investigations and acoustical modelling indicated that the F0 of male bugles is consistent with the vocal fold dimensions reported in this species, whereas the secondary, much higher source at G0 is more consistent with an aerodynamic whistle produced as air flows rapidly through a narrow supraglottic constriction. We also report a possible interaction between the higher frequency G0 and vocal tract resonances, as G0 transiently locks onto individual formants as the vocal tract is extended. We speculate that male wapiti have evolved such a dual-source phonation to advertise body size at close range (with a relatively low-frequency F0 providing a dense spectrum to highlight size-related information contained in formants) while simultaneously advertising their presence over greater distances using the very high-amplitude G0 whistle component. © 2016. Published by The Company of Biologists Ltd.

  12. Morphometric assessment of normal human ciliary body using ultrasound biomicroscopy.

    PubMed

    Okamoto, Yoshifumi; Okamoto, Fumiki; Nakano, Shinichiro; Oshika, Tetsuro

    2017-12-01

    To quantitatively assess the biometry of the ciliary body in normal human eyes using ultrasound biomicroscopy. We evaluated 85 eyes of 85 normal subjects (35 men and 50 women), whose age ranged from 11 to 86 years (mean ± SD, 56.8 ± 20.4 years). The eyes were assessed along the 3-, 6-, 9-, and 12-o'clock meridians relative to the center of the cornea. Clinical data were collected, including age, axial length, ciliary body length (CBL), ciliary body thickness (CBT), anterior chamber depth, iris root thickness, trabecular-iris angle, and scleral-ciliary process angle. Axial length was measured using A-scan ultrasonography. CBL and CBT tended to be larger in the superior than in the inferior quadrant, but the differences among the four quadrants were not statistically significant. The average CBL showed a significant positive correlation with the average CBT (r = 0.40, P < 0.001). Average CBL and CBT were significantly correlated with axial length (r = 0.33, P = 0.031; r = 0.46, P < 0.01 respectively). In addition, the average CBL was significantly correlated with anterior chamber depth (r = 0.23, P < 0.05), trabecular-iris angle (r = 0.29, P = 0.01), and scleral-ciliary process angle (r = 0.40, P < 0.001). Ultrasound biomicroscopic imaging demonstrated that the ciliary body is similar in size in all circumferences, and eyes with longer axial length have an elongated and thicker ciliary body. The values obtained in the present study may serve as standard clinical references.

  13. Performance enhancement for audio-visual speaker identification using dynamic facial muscle model.

    PubMed

    Asadpour, Vahid; Towhidkhah, Farzad; Homayounpour, Mohammad Mehdi

    2006-10-01

    Science of human identification using physiological characteristics or biometry has been of great concern in security systems. However, robust multimodal identification systems based on audio-visual information has not been thoroughly investigated yet. Therefore, the aim of this work to propose a model-based feature extraction method which employs physiological characteristics of facial muscles producing lip movements. This approach adopts the intrinsic properties of muscles such as viscosity, elasticity, and mass which are extracted from the dynamic lip model. These parameters are exclusively dependent on the neuro-muscular properties of speaker; consequently, imitation of valid speakers could be reduced to a large extent. These parameters are applied to a hidden Markov model (HMM) audio-visual identification system. In this work, a combination of audio and video features has been employed by adopting a multistream pseudo-synchronized HMM training method. Noise robust audio features such as Mel-frequency cepstral coefficients (MFCC), spectral subtraction (SS), and relative spectra perceptual linear prediction (J-RASTA-PLP) have been used to evaluate the performance of the multimodal system once efficient audio feature extraction methods have been utilized. The superior performance of the proposed system is demonstrated on a large multispeaker database of continuously spoken digits, along with a sentence that is phonetically rich. To evaluate the robustness of algorithms, some experiments were performed on genetically identical twins. Furthermore, changes in speaker voice were simulated with drug inhalation tests. In 3 dB signal to noise ratio (SNR), the dynamic muscle model improved the identification rate of the audio-visual system from 91 to 98%. Results on identical twins revealed that there was an apparent improvement on the performance for the dynamic muscle model-based system, in which the identification rate of the audio-visual system was enhanced from 87 to 96%.

  14. Maternal iron intake at mid-pregnancy is associated with reduced fetal growth: results from Mothers and Children's Environmental Health (MOCEH) study.

    PubMed

    Hwang, Ji-Yun; Lee, Ji-Yeon; Kim, Ki-Nam; Kim, Hyesook; Ha, Eun-Hee; Park, Hyesook; Ha, Mina; Kim, Yangho; Hong, Yun-Chul; Chang, Namsoo

    2013-04-02

    Iron supplementation is a common recommendation for pregnant women to prevent iron deficiency during pregnancy. There is an increasing concern about excessive iron consumption as a general iron prophylaxis by pregnant women without any due consideration about their dietary iron intake or iron status. Our present study investigated the association between total iron intake from diet and supplements and fetal growth in 337 pregnant women at mid-pregnancy in South Korea. Iron intake from diet and supplements was examined by a 24-hour recall method. Subjects were divided into three groups based on tertiles of total iron intake levels. Fetal biometry was assessed by ultrasonography at mid-pregnancy. About 99% of the non-supplement users had iron intake below the recommended nutrient intake (RNI) for pregnant women (24 mg), whereas 64.9% of supplement users had iron intake above the upper level (UL) (45 mg). In the babies of mothers in the third tertile of iron intake (>17.04 mg), biparietal diameter, abdominal circumference, and femur length were lower by 0.41 cm (P =0.019), 0.41 cm (P = 0.027), and 0.07 cm (P = 0.051), respectively, than the babies of mothers in the second tertile of iron intake (11.49 ~ 17.04 mg). These results suggest that excessive maternal iron intake at mid-pregnancy is associated with reduced fetal growth. Iron supplementation for pregnant women should be individualized according to their iron status. Appropriate diet education is needed for pregnant women so that they can consume adequate amounts of iron from food and supplements.

  15. WHO multicentre study for the development of growth standards from fetal life to childhood: the fetal component.

    PubMed

    Merialdi, Mario; Widmer, Mariana; Gülmezoglu, Ahmet Metin; Abdel-Aleem, Hany; Bega, George; Benachi, Alexandra; Carroli, Guillermo; Cecatti, Jose Guilherme; Diemert, Anke; Gonzalez, Rogelio; Hecher, Kurt; Jensen, Lisa N; Johnsen, Synnøve L; Kiserud, Torvid; Kriplani, Alka; Lumbiganon, Pisake; Tabor, Ann; Talegawkar, Sameera A; Tshefu, Antoinette; Wojdyla, Daniel; Platt, Lawrence

    2014-05-02

    In 2006 WHO presented the infant and child growth charts suggested for universal application. However, major determinants for perinatal outcomes and postnatal growth are laid down during antenatal development. Accordingly, monitoring fetal growth in utero by ultrasonography is important both for clinical and scientific reasons. The currently used fetal growth references are derived mainly from North American and European population and may be inappropriate for international use, given possible variances in the growth rates of fetuses from different ethnic population groups. WHO has, therefore, made it a high priority to establish charts of optimal fetal growth that can be recommended worldwide. This is a multi-national study for the development of fetal growth standards for international application by assessing fetal growth in populations of different ethnic and geographic backgrounds. The study will select pregnant women of high-middle socioeconomic status with no obvious environmental constraints on growth (adequate nutritional status, non-smoking), and normal pregnancy history with no complications likely to affect fetal growth. The study will be conducted in centres from ten developing and industrialized countries: Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand. At each centre, 140 pregnant women will be recruited between 8 + 0 and 12 + 6 weeks of gestation. Subsequently, visits for fetal biometry will be scheduled at 14, 18, 24, 28, 32, 36, and 40 weeks (+/- 1 week) to be performed by trained ultrasonographers.The main outcome of the proposed study will be the development of fetal growth standards (either global or population specific) for international applications. The data from this study will be incorporated into obstetric practice and national health policies at country level in coordination with the activities presently conducted by WHO to implement the use of the Child Growth Standards.

  16. Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens design

    PubMed Central

    Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando

    2018-01-01

    Purpose To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. Methods In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP®) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820®). Results YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 (p=0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm (p=0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm (p=0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups (p>0.05). Conclusion YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant. PMID:29593378

  17. Eye size and shape in newborn children and their relation to axial length and refraction at 3 years.

    PubMed

    Lim, Laurence Shen; Chua, Sharon; Tan, Pei Ting; Cai, Shirong; Chong, Yap-Seng; Kwek, Kenneth; Gluckman, Peter D; Fortier, Marielle V; Ngo, Cheryl; Qiu, Anqi; Saw, Seang-Mei

    2015-07-01

    To determine if eye size and shape at birth are associated with eye size and refractive error 3 years later. A subset of 173 full-term newborn infants from the Growing Up in Singapore Towards healthy Outcomes (GUSTO) birth cohort underwent magnetic resonance imaging (MRI) to measure the dimensions of the internal eye. Eye shape was assessed by an oblateness index, calculated as 1 - (axial length/width) or 1 - (axial length/height). Cycloplegic autorefraction (Canon Autorefractor RK-F1) and optical biometry (IOLMaster) were performed 3 years later. Both eyes of 173 children were analysed. Eyes with longer axial length at birth had smaller increases in axial length at 3 years (p < 0.001). Eyes with larger baseline volumes and surface areas had smaller increases in axial length at 3 years (p < 0.001 for both). Eyes which were more oblate at birth had greater increases in axial length at 3 years (p < 0.001). Using width to calculate oblateness, prolate eyes had smaller increases in axial length at 3 years compared to oblate eyes (p < 0.001), and, using height, prolate and spherical eyes had smaller increases in axial length at 3 years compared to oblate eyes (p < 0.001 for both). There were no associations between eye size and shape at birth and refraction, corneal curvature or myopia at 3 years. Eyes that are larger and have prolate or spherical shapes at birth exhibit smaller increases in axial length over the first 3 years of life. Eye size and shape at birth influence subsequent eye growth but not refractive error development. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  18. Posterior Eye Shape Measurement With Retinal OCT Compared to MRI

    PubMed Central

    Kuo, Anthony N.; Verkicharla, Pavan K.; McNabb, Ryan P.; Cheung, Carol Y.; Hilal, Saima; Farsiu, Sina; Chen, Christopher; Wong, Tien Y.; Ikram, M. Kamran; Cheng, Ching Y.; Young, Terri L.; Saw, Seang M.; Izatt, Joseph A.

    2016-01-01

    Purpose Posterior eye shape assessment by magnetic resonance imaging (MRI) is used to study myopia. We tested the hypothesis that optical coherence tomography (OCT), as an alternative, could measure posterior eye shape similarly to MRI. Methods Macular spectral-domain OCT and brain MRI images previously acquired as part of the Singapore Epidemiology of Eye Diseases study were analyzed. The right eye in the MRI and OCT images was automatically segmented. Optical coherence tomography segmentations were corrected for optical and display distortions requiring biometry data. The segmentations were fitted to spheres and ellipsoids to obtain the posterior eye radius of curvature (Rc) and asphericity (Qxz). The differences in Rc and Qxz measured by MRI and OCT were tested using paired t-tests. Categorical assignments of prolateness or oblateness using Qxz were compared. Results Fifty-two subjects (67.8 ± 5.6 years old) with spherical equivalent refraction from +0.50 to −5.38 were included. The mean paired difference between MRI and original OCT posterior eye Rc was 24.03 ± 46.49 mm (P = 0.0005). For corrected OCT images, the difference in Rc decreased to −0.23 ± 2.47 mm (P = 0.51). The difference between MRI and OCT asphericity, Qxz, was −0.052 ± 0.343 (P = 0.28). However, categorical agreement was only moderate (κ = 0.50). Conclusions Distortion-corrected OCT measurements of Rc and Qxz were not statistically significantly different from MRI, although the moderate categorical agreement suggests that individual differences remained. This study provides evidence that with distortion correction, noninvasive office-based OCT could potentially be used instead of MRI for the study of posterior eye shape. PMID:27409473

  19. Computing retinal contour from optical biometry.

    PubMed

    Faria-Ribeiro, Miguel; López-Gil, Norberto; Navarro, Rafael; Lopes-Ferreira, Daniela; Jorge, Jorge; González-Méijome, Jose Manuel

    2014-04-01

    To describe a new methodology that derives horizontal posterior retinal contours from partial coherence interferometry (PCI) and ray tracing using the corneal topography. Corneal topography and PCI for seven horizontal visual field eccentricities correspondent to the central 60 degrees of the posterior pole were obtained in 55 myopic eyes. A semicustomized eye model based on the subject's corneal topography and the Navarro eye model was generated using Zemax-EE software. The model was used to compute the optical path length in the seven directions where PCI measurements were obtained. Vitreous chamber depth was computed using the PCI values obtained at each of those directions. Matlab software was developed to fit the best conic curve to the set of points previously obtained. We tested the limit in the accuracy of the methodology when the actual cornea of the subject is not used and for two different lens geometries. A standard eye model can induce an error in the retina sagitta estimation of the order of hundreds of micrometers in comparison with the semicustomized eye model. However, the use of a different lens model leads to an error of the order of tens of micrometers. The apical radius and conic constant of the average fit were -11.91 mm and -0.15, respectively. In general, a nasal-temporal asymmetry in the retina contour was found, showing mean larger values of vitreous chamber depth in the nasal side of the eye. The use of a semicustomized eye model, together with optical path length measured by PCI for different angles, can be used to predict the retinal contour within tenths of micrometers. This methodology can be useful in studies trying to understand the effect of peripheral retinal location on myopia progression as well as modeling the optics of the human eye for a wide field.

  20. PALEOBIOLOGICAL APPLICATIONS OF THREE-DIMENSIONAL BIOMETRY ON LARGER BENTHIC FORAMINIFERA: A NEW ROUTE OF DISCOVERIES

    PubMed Central

    Briguglio, Antonino; Hohenegger, Johann; Less, György

    2015-01-01

    Four specimens of larger benthic foraminifera (the Recent Palaeonummulites venosus and Operculina ammonoides, and the phylogenetically related Paleogene Nummulites fabianii and N. fichteli) were investigated by X-ray tomography. The resulting three-dimensional measurements enabled a comprehensive, quantitative study of shell morphology to interpret cell growth without specific shell preparation and/or destruction. After segmentation and extraction of all scanned lumina, the following characters were measured on all chambers of each specimen: chamber volume, septal distance, chamber height, and chamber width. The sequence of chamber lumina follows either a logistic function (Palaeonummulites, Operculina), where the deceleration in growth rate of the latest chambers could mark the onset of reproduction, or it can be modeled by a series of stepwise functions with differing constants (Nummulites). Variations around the growth model are either periodic, following external cycles, or random as expressed by abrupt deviations. Therefore, they may reflect the response of the cell to environmental changes in terms of cyclic changes (e.g., seasonality) or single events (e.g., predator attack). Correlations between chamber volume and the other chamber parameters show that septal distance always matches the sequence in chamber volume and can therefore be used as a proxy for environmental analyses in both growth models. Chamber height and width often remain constant around their function and rarely deviate drastically to accommodate the needed lumen for retaining test size and shape. Chamber width may vary according to chamber volume in involute specimens, whereas both chamber height and width correlate with volume in those tests following an Archimedean spiral. X-ray-tomography shows particular promise in determining which parameters that can be assessed routinely in two dimensions primarily reflect environmental conditions vs. parameters best used for taxonomic identification and for systematic lineage reconstruction. PMID:26166915

  1. Corneal Deformation Response and Ocular Geometry: A Noninvasive Diagnostic Strategy in Marfan Syndrome.

    PubMed

    Beene, Lauren C; Traboulsi, Elias I; Seven, Ibrahim; Ford, Matthew R; Sinha Roy, Abhijit; Butler, Robert S; Dupps, William J

    2016-01-01

    To evaluate corneal air-puff deformation responses and ocular geometry as predictors of Marfan syndrome. Prospective observational clinical study. Sixteen investigator-derived, 4 standard Ocular Response Analyzer (ORA), and geometric variables from corneal tomography and optical biometry using Oculus Pentacam and IOL Master were assessed for discriminative value in Marfan syndrome, measuring right eyes of 24 control and 13 Marfan syndrome subjects. Area under the receiver operating characteristic (AUROC) curve was assessed in univariate and multivariate analyses. Six investigator-derived ORA variables successfully discriminated Marfan syndrome. The best lone disease predictor was Concavity Min (Marfan syndrome 47.5 ± 20, control 69 ± 14, P = .003; AUROC = 0.80). Corneal hysteresis (CH) and corneal resistance factor (CRF) were decreased (Marfan syndrome CH 9.45 ± 1.62, control CH 11.24 ± 1.21, P = .01; Marfan syndrome CRF 9.77 ± 1.65, control CRF 11.03 ± 1.72, P = .01) and corneas were flatter in Marfan syndrome (Marfan syndrome Kmean 41.25 ± 2.09 diopter, control Kmean 42.70 ± 1.81 diopter, P = .046). No significant differences were observed in central corneal thickness, axial eye length, or intraocular pressure. A multivariate regression model incorporating corneal curvature and hysteresis loop area (HLA) provided the best predictive value for Marfan syndrome (AUROC = 0.85). This study describes novel biodynamic features of corneal deformation responses in Marfan syndrome, including increased deformation, decreased bending resistance, and decreased energy dissipation capacity. A predictive model incorporating HLA and corneal curvature shows greatest potential for noninvasive clinical diagnosis of Marfan syndrome. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Corneal Deformation Response and Ocular Geometry: A Non-invasive Diagnostic Strategy in Marfan Syndrome

    PubMed Central

    Beene, Lauren C.; Traboulsi, Elias I.; Seven, Ibrahim; Ford, Matthew R.; Roy, Abhijit Sinha; Butler, Robert S.; Dupps, William J.

    2015-01-01

    Purpose To evaluate corneal air-puff deformation responses and ocular geometry as predictors of Marfan syndrome. Design Prospective observational clinical study Methods Sixteen investigator-derived, 4 standard Ocular Response Analyzer (ORA), and geometric variables from corneal tomography and optical biometry using Oculus Pentacam and IOL Master were assessed for discriminative value in Marfan syndrome, measuring right eyes of 24 control and 13 Marfan syndrome subjects. Area under the receiver operating characteristic (AUROC) curve was assessed in univariate and multivariate analyses Results Six investigator-derived ORA variables successfully discriminated Marfan syndrome. The best lone disease predictor was Concavity Min (Marfan syndrome 47.5 ± 20, control 69 ± 14, p = 0.003; AUROC = 0.80). Corneal hysteresis and corneal resistance factor were decreased (Marfan syndrome CH 9.45 ± 1.62, control CH 11.24 ± 1.21, p = 0.01; Marfan syndrome CRF 9.77 ± 1.65, control CRF 11.03 ± 1.72, p = 0.01) and corneas were flatter in Marfan syndrome (Marfan syndrome Kmean 41.25 ± 2.09 D, control Kmean 42.70 ± 1.81 D, p = 0.046). No significant differences were observed in central corneal thickness, axial eye length, or intraocular pressure. A multivariate regression model incorporating corneal curvature and hysteresis loop area (HLA) provided the best predictive value for Marfan syndrome (AUROC = 0.85). Conclusions This study describes novel biodynamic features of corneal deformation responses in Marfan syndrome, including increased deformation, decreased bending resistance, and decreased energy dissipation capacity. A predictive model incorporating HLA and corneal curvature shows greatest potential for non-invasive clinical diagnosis of Marfan syndrome. PMID:26432567

  3. Present situation and prospect of medical knowledge based systems in German-speaking countries: results of an online survey.

    PubMed

    Spreckelsen, Cord; Spitzer, K; Honekamp, W

    2012-01-01

    After a decrease of interest in classical medical expert systems, the publication activity concerning the medical application of Artificial Intelligence and the interest in medical decision support have markedly increased. Nonetheless, no systematic exploratory study has yet been carried out, which directly considers the actual fields of applications, exemplary approaches, obstacles, challenges, and future prospect as seen by pioneering users and developers in a given region. This paper reports the results of an online survey designed to fill this gap with the "Knowledge Based Systems" working group of the German Society for Medical Informatics, Biometry and Epidemiology (GMDS) in 2010. The survey was based on an online questionnaire (5 single and multiple choice questions, 8 Likert-scaled items, 7 free text questions) consented to by the working group. The answers were analyzed by descriptive statistics and a qualitative analysis (bottom-up coding). All academic institutions of Medical Informatics in the German-speaking countries and contributors reporting KBS-related projects at the relevant scientific conferences and in a journal specialized in the field were invited to participate. The survey reached a response rate of 33.4%. The results show a gap between the reported obstacles of medical KBS (mainly low acceptance and rare use in clinical practice) and their future prospect as stated by the participants. Problems previously discussed in the literature like low acceptance, integration, and sustainability of KBS projects were confirmed. The current situation was characterized by naming exemplary existing systems and specifying promising fields of application. The field of KBS in medicine is more diversified and has evolved beyond expectations in the German-speaking countries.

  4. Profile of refractive errors in cerebral palsy: impact of severity of motor impairment (GMFCS) and CP subtype on refractive outcome.

    PubMed

    Saunders, Kathryn J; Little, Julie-Anne; McClelland, Julie F; Jackson, A Jonathan

    2010-06-01

    To describe refractive status in children and young adults with cerebral palsy (CP) and relate refractive error to standardized measures of type and severity of CP impairment and to ocular dimensions. A population-based sample of 118 participants aged 4 to 23 years with CP (mean 11.64 +/- 4.06) and an age-appropriate control group (n = 128; age, 4-16 years; mean, 9.33 +/- 3.52) were recruited. Motor impairment was described with the Gross Motor Function Classification Scale (GMFCS), and subtype was allocated with the Surveillance of Cerebral Palsy in Europe (SCPE). Measures of refractive error were obtained from all participants and ocular biometry from a subgroup with CP. A significantly higher prevalence and magnitude of refractive error was found in the CP group compared to the control group. Axial length and spherical refractive error were strongly related. This relation did not improve with inclusion of corneal data. There was no relation between the presence or magnitude of spherical refractive errors in CP and the level of motor impairment, intellectual impairment, or the presence of communication difficulties. Higher spherical refractive errors were significantly associated with the nonspastic CP subtype. The presence and magnitude of astigmatism were greater when intellectual impairment was more severe, and astigmatic errors were explained by corneal dimensions. Conclusions. High refractive errors are common in CP, pointing to impairment of the emmetropization process. Biometric data support this In contrast to other functional vision measures, spherical refractive error is unrelated to CP severity, but those with nonspastic CP tend to demonstrate the most extreme errors in refraction.

  5. Refractive errors and ocular biometry components in thalassemia major patients.

    PubMed

    Heydarian, Samira; Jafari, Reza; Karami, Hosein

    2016-04-01

    The aim of this study is to determine and compare biometric and refractive characteristics of thalassemia major patients and normal individuals. In this cross-sectional study, 54 thalassemia major patients were selected randomly as case group, and 54 age- and sex-matched healthy subjects were regarded as control group. Refractive errors, corneal curvature and ocular components were measured by autokeratorefractometery and A-scan ultrasonography, respectively. Mean spherical equivalent was -0.0093 ± 0.86 D in thalassemia patients and -0.22 ± 1.33 D in the normal group. The prevalence of myopia, Hyperopia, and emmetropia among thalassemia patients was 16.7, 19.4, and 63.9 %, respectively. While in the control group, 26.9 % were myopic, 25 % were hyperopic, and 48.1 % were emmetropic. The prevalence of astigmatism in case group was 22.2 %, which was not significantly different from that in control group, (27.8 %, p = 0.346). Mean axial length in thalassemia patients was 22.89 ± 0.70 which was significantly lower than that in normal group (23.37 ± 0.91, p = 0.000). The flattest meridian of the cornea (R1) was significantly steeper in thalassemia patients (7.77 ± 0.24) in comparison to normal individuals (7.85 ± 0.28). Although thalassemic patients had significantly smaller axial length and vitreous chamber depth in comparison to normal group, which could be due to their abnormal physical growth, there was no significant difference between the mean of spherical equivalent among two groups. This can be due to their steeper corneal curvature that overcomes the refractive disadvantage of their shorter axial length.

  6. Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation.

    PubMed

    Hirnschall, Nino; Norrby, Sverker; Weber, Maria; Maedel, Sophie; Amir-Asgari, Sahand; Findl, Oliver

    2015-01-01

    To include intraoperative measurements of the anterior lens capsule of the aphakic eye into the intraocular lens power calculation (IPC) process and to compare the refractive outcome with conventional IPC formulae. In this prospective study, a prototype operating microscope with an integrated continuous optical coherence tomography (OCT) device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior lens capsule position after implanting a capsular tension ring (CTR). Optical biometry (intraocular lens (IOL) Master 500) and ACMaster measurements (Carl Zeiss Meditec AG, Germany) were performed before surgery. Autorefraction and subjective refraction were performed 3 months after surgery. Conventional IPC formulae were compared with a new intraoperatively measured anterior chamber depth (ACD) (ACDIntraOP) partial least squares regression (PLSR) model for prediction of the postoperative refractive outcome. In total, 70 eyes of 70 patients were included. Mean axial eye length (AL) was 23.3 mm (range: 20.6-29.5 mm). Predictive power of the intraoperative measurements was found to be slightly better compared to conventional IOL power calculations. Refractive error dependency on AL for Holladay I, HofferQ, SRK/T, Haigis and ACDintraOP PLSR was r(2)=-0.42 (p<0.0001), r(2)=-0.5 (p<0.0001), r(2)=-0.34 (p=0.010), r(2)=-0.28 (p=0.049) and r(2)<0.001 (p=0.866), respectively, ACDIntraOP measurements help to better predict the refractive outcome and could be useful, if implemented in fourth-generation IPC formulae. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. [Fetal growth and activity at 20 to 24 weeks of gestation (preliminary study)].

    PubMed

    Conde, Ana; Figueiredo, Bárbara; Tendais, Iva; Pereira, Ana F; Afonso, Elisa; Nogueira, Raúl

    2008-01-01

    Recent researches show that psychological development begins much before birth and prenatal influences can explain a significant part of the future variability in infants' behaviour and development. The aim of this study was to characterize the fetal development between 20 and 24 weeks of gestation, related to the measures of fetal growth-- iparietal diameter, abdominal circumference, head circumference, femur length and fetal weight-- and fetal activity--fetal heart rate and fetal movements. We also tried to establish if there are any differences in these measures related to the mothers' and fetus' sociodemographic features, obstetrical conditions and exposure to drugs. The sample of this study involved 48 fetus (52.1% female and 47.9% male) with an estimated gestational age (GA) between 20-24 weeks (Mean = 21 weeks and 1 day), whose mothers had appointments at the Obstetric and Gynaecological medical consultation of Júlio Dinis Maternity Hospital (MJD, Oporto). A video tape of the fetal behaviour was made and ultrasound biometry measurements were collected from the morphological ultrasound report. A statistical analysis of fetal data, after gestational age control, showed differences in fetal growth measures related to mothers' occupational status [F(1,41) = 7.28; p = .000], marital status [F(1,41) = 2.61; p = .04], household arrangements [F(1,41) = 2.91; p = .03] and coffee consumption [F(1,40) = 2.55; p = .05]. Differences in fetal activity measures (fetal heart rate) associated to fetus gender [F(1,16) = 5.84; p = .009] were also found. We can conclude about the sensibility of fetal development to prenatal factors related to the mothers' and fetus' sociodemographic features and exposure to drugs.

  8. A possible new approach in the prediction of late gestational hypertension: The role of the fetal aortic intima-media thickness.

    PubMed

    Visentin, Silvia; Londero, Ambrogio P; Camerin, Martina; Grisan, Enrico; Cosmi, Erich

    2017-01-01

    The aim was to determine the predictive role of combined screening for late-onset gestational hypertension by fetal ultrasound measurements, third trimester uterine arteries (UtAs) Doppler imaging, and maternal history. This prospective study on singleton pregnancies was conducted at the tertiary center of Maternal and Fetal Medicine of the University of Padua during the period between January 2012 and December 2014. Ultrasound examination (fetal biometry, fetal wellbeing, maternal Doppler study, fetal abdominal aorta intima-media thickness [aIMT], and fetal kidney volumes), clinical data (mother age, prepregnancy body mass index [BMI], and parity), and pregnancy outcomes were collected. The P value <0.05 was defined significant considering a 2-sided alternative hypothesis. The distribution normality of variables were assessed using Kolmogorov-Smirnoff test. Data were presented by mean (±standard deviation), median and interquartile range, or percentage and absolute values. We considered data from 1381 ultrasound examinations at 29 to 32 weeks' gestation, and in 73 cases late gestational hypertension developed after 34 weeks' gestation. The final multivariate model found that fetal aIMT as well as fetal umbilical artery pulsatility index (PI), maternal age, maternal prepregnacy BMI, parity, and mean PI of maternal UtAs, assessed at ultrasound examination of 29 to 32 weeks' gestation, were significant and independent predictors for the development of gestational hypertension after 34 weeks' gestation. The area under the curve of the model was 81.07% (95% confidence interval, 75.83%-86.32%). A nomogram was developed starting from multivariate logistic regression coefficients. Late-gestational hypertension could be independently predicted by fetal aIMT assessment at 29 to 32 weeks' gestation, ultrasound Doppler waveforms, and maternal clinical parameters.

  9. A possible new approach in the prediction of late gestational hypertension

    PubMed Central

    Visentin, Silvia; Londero, Ambrogio P.; Camerin, Martina; Grisan, Enrico; Cosmi, Erich

    2017-01-01

    Abstract The aim was to determine the predictive role of combined screening for late-onset gestational hypertension by fetal ultrasound measurements, third trimester uterine arteries (UtAs) Doppler imaging, and maternal history. This prospective study on singleton pregnancies was conducted at the tertiary center of Maternal and Fetal Medicine of the University of Padua during the period between January 2012 and December 2014. Ultrasound examination (fetal biometry, fetal wellbeing, maternal Doppler study, fetal abdominal aorta intima-media thickness [aIMT], and fetal kidney volumes), clinical data (mother age, prepregnancy body mass index [BMI], and parity), and pregnancy outcomes were collected. The P value <0.05 was defined significant considering a 2-sided alternative hypothesis. The distribution normality of variables were assessed using Kolmogorov–Smirnoff test. Data were presented by mean (±standard deviation), median and interquartile range, or percentage and absolute values. We considered data from 1381 ultrasound examinations at 29 to 32 weeks’ gestation, and in 73 cases late gestational hypertension developed after 34 weeks’ gestation. The final multivariate model found that fetal aIMT as well as fetal umbilical artery pulsatility index (PI), maternal age, maternal prepregnacy BMI, parity, and mean PI of maternal UtAs, assessed at ultrasound examination of 29 to 32 weeks’ gestation, were significant and independent predictors for the development of gestational hypertension after 34 weeks’ gestation. The area under the curve of the model was 81.07% (95% confidence interval, 75.83%–86.32%). A nomogram was developed starting from multivariate logistic regression coefficients. Late-gestational hypertension could be independently predicted by fetal aIMT assessment at 29 to 32 weeks’ gestation, ultrasound Doppler waveforms, and maternal clinical parameters. PMID:28079791

  10. EULAR recommendations for women's health and the management of family planning, assisted reproduction, pregnancy and menopause in patients with systemic lupus erythematosus and/or antiphospholipid syndrome

    PubMed Central

    Bertsias, G K; Agmon-Levin, N; Brown, S; Cervera, R; Costedoat-Chalumeau, N; Doria, A; Fischer-Betz, R; Forger, F; Moraes-Fontes, M F; Khamashta, M; King, J; Lojacono, A; Marchiori, F; Meroni, P L; Mosca, M; Motta, M; Ostensen, M; Pamfil, C; Raio, L; Schneider, M; Svenungsson, E; Tektonidou, M; Yavuz, S; Boumpas, D; Tincani, A

    2017-01-01

    Objectives Develop recommendations for women's health issues and family planning in systemic lupus erythematosus (SLE) and/or antiphospholipid syndrome (APS). Methods Systematic review of evidence followed by modified Delphi method to compile questions, elicit expert opinions and reach consensus. Results Family planning should be discussed as early as possible after diagnosis. Most women can have successful pregnancies and measures can be taken to reduce the risks of adverse maternal or fetal outcomes. Risk stratification includes disease activity, autoantibody profile, previous vascular and pregnancy morbidity, hypertension and the use of drugs (emphasis on benefits from hydroxychloroquine and antiplatelets/anticoagulants). Hormonal contraception and menopause replacement therapy can be used in patients with stable/inactive disease and low risk of thrombosis. Fertility preservation with gonadotropin-releasing hormone analogues should be considered prior to the use of alkylating agents. Assisted reproduction techniques can be safely used in patients with stable/inactive disease; patients with positive antiphospholipid antibodies/APS should receive anticoagulation and/or low-dose aspirin. Assessment of disease activity, renal function and serological markers is important for diagnosing disease flares and monitoring for obstetrical adverse outcomes. Fetal monitoring includes Doppler ultrasonography and fetal biometry, particularly in the third trimester, to screen for placental insufficiency and small for gestational age fetuses. Screening for gynaecological malignancies is similar to the general population, with increased vigilance for cervical premalignant lesions if exposed to immunosuppressive drugs. Human papillomavirus immunisation can be used in women with stable/inactive disease. Conclusions Recommendations for women's health issues in SLE and/or APS were developed using an evidence-based approach followed by expert consensus. PMID:27457513

  11. Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

    PubMed

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-11-21

    To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.

  12. Comparison of Factors Associated With Occludable Angle Between American Caucasians and Ethnic Chinese

    PubMed Central

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-01-01

    Purpose. To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. Methods. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40–80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. Results. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Conclusions. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese. PMID:24168992

  13. Developmental toxicity of PAH mixtures in fish early life stages. Part I: adverse effects in rainbow trout.

    PubMed

    Le Bihanic, Florane; Morin, Bénédicte; Cousin, Xavier; Le Menach, Karyn; Budzinski, Hélène; Cachot, Jérôme

    2014-12-01

    A new gravel-contact assay using rainbow trout, Oncorhynchus mykiss, embryos was developed to assess the toxicity of polycyclic aromatic hydrocarbons (PAHs) and other hydrophobic compounds. Environmentally realistic exposure conditions were mimicked with a direct exposure of eyed rainbow trout embryos incubated onto chemical-spiked gravels until hatching at 10 °C. Several endpoints were recorded including survival, hatching delay, hatching success, biometry, developmental abnormalities, and DNA damage (comet and micronucleus assays). This bioassay was firstly tested with two model PAHs, fluoranthene and benzo[a]pyrene. Then, the method was applied to compare the toxicity of three PAH complex mixtures characterized by different PAH compositions: a pyrolytic extract from a PAH-contaminated sediment (Seine estuary, France) and two petrogenic extracts from Arabian Light and Erika oils, at two environmental concentrations, 3 and 10 μg g(-1) sum of PAHs. The degree and spectrum of toxicity were different according to the extract considered. Acute effects including embryo mortality and decreased hatching success were observed only for Erika oil extract. Arabian Light and pyrolytic extracts induced mainly sublethal effects including reduced larvae size and hemorrhages. Arabian Light and Erika extracts both induced repairable DNA damage as revealed by the comet assay versus the micronucleus assay. The concentration and proportion of methylphenanthrenes and methylanthracenes appeared to drive the toxicity of the three PAH fractions tested, featuring a toxic gradient as follows: pyrolytic < Arabian Light < Erika. The minimal concentration causing developmental defects was as low as 0.7 μg g(-1) sum of PAHs, indicating the high sensitivity of the assay and validating its use for toxicity assessment of particle-bound pollutants.

  14. PALEOBIOLOGICAL APPLICATIONS OF THREE-DIMENSIONAL BIOMETRY ON LARGER BENTHIC FORAMINIFERA: A NEW ROUTE OF DISCOVERIES.

    PubMed

    Briguglio, Antonino; Hohenegger, Johann; Less, György

    2013-01-01

    Four specimens of larger benthic foraminifera (the Recent Palaeonummulites venosus and Operculina ammonoides , and the phylogenetically related Paleogene Nummulites fabianii and N. fichteli ) were investigated by X-ray tomography. The resulting three-dimensional measurements enabled a comprehensive, quantitative study of shell morphology to interpret cell growth without specific shell preparation and/or destruction. After segmentation and extraction of all scanned lumina, the following characters were measured on all chambers of each specimen: chamber volume, septal distance, chamber height, and chamber width. The sequence of chamber lumina follows either a logistic function ( Palaeonummulites , Operculina ), where the deceleration in growth rate of the latest chambers could mark the onset of reproduction, or it can be modeled by a series of stepwise functions with differing constants ( Nummulites ). Variations around the growth model are either periodic, following external cycles, or random as expressed by abrupt deviations. Therefore, they may reflect the response of the cell to environmental changes in terms of cyclic changes (e.g., seasonality) or single events (e.g., predator attack). Correlations between chamber volume and the other chamber parameters show that septal distance always matches the sequence in chamber volume and can therefore be used as a proxy for environmental analyses in both growth models. Chamber height and width often remain constant around their function and rarely deviate drastically to accommodate the needed lumen for retaining test size and shape. Chamber width may vary according to chamber volume in involute specimens, whereas both chamber height and width correlate with volume in those tests following an Archimedean spiral. X-ray-tomography shows particular promise in determining which parameters that can be assessed routinely in two dimensions primarily reflect environmental conditions vs. parameters best used for taxonomic identification and for systematic lineage reconstruction.

  15. Digitization of the human body in the present-day economy

    NASA Astrophysics Data System (ADS)

    D'Apuzzo, Nicola

    2005-01-01

    In this paper we report on the historic development of human body digitization and on the actual state of commercially available technology. Complete systems for the digitization of the human body exist since more than ten years. One of the main users of this technology was the entertainment industry. Every new movie excited with attractive visual effects, but only few people knew that the most thrilling cuts were realized by using virtual persons. The faces and bodies of actors were digitized and the "virtual twin" replaced the actor in the movie. Nowadays, the state of the human body digitization is so high that it is not possible any more to distinguish the real actor from the virtual one. Indeed, for the rush technical development has to be thanked the movie industry, which was one of the strong economic motors for this technology. Today, with the possibility of a massive cost reduction given by new technologies, methods for digitization of the human body are used also in other fields of application, such as ergonomics, medical applications, computer games, biometry and anthropometrics. With the time, this technology becomes interesting also for sport, fitness, fashion and beauty. A large expansion of human body digitization is expected in the near future. To date, different technologies are used commercially for the measurement of the human body. They can be divided into three distinguished groups: laser-scanning, projection of light patterns, combination modeling and image processing. The different solutions have strengths and weaknesses that profile their suitability for specific applications. This paper gives an overview of their differences and characteristics and expresses clues for the selection of the adequate method. Practical examples of commercial exploitation of human body digitization are also presented and new interesting perspectives are introduced.

  16. Femtosecond laser-assisted cataract surgeries reported to the European Registry of Quality Outcomes for Cataract and Refractive Surgery: Baseline characteristics, surgical procedure, and outcomes.

    PubMed

    Lundström, Mats; Dickman, Mor; Henry, Ype; Manning, Sonia; Rosen, Paul; Tassignon, Marie-José; Young, David; Stenevi, Ulf

    2017-12-01

    To describe a large cohort of femtosecond laser-assisted cataract surgeries in terms of baseline characteristics and the related outcomes. Eighteen cataract surgery clinics in 9 European countries and Australia. Prospective multicenter case series. Data on consecutive eyes having femtosecond laser-assisted cataract surgery in the participating clinics were entered in the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO). A trained registry manager in each clinic was responsible for valid reporting to the EUREQUO. Demographics, preoperative corrected distance visual acuity (CDVA), risk factors, type of surgery, type of intraocular lens, visual outcomes, refractive outcomes, and complications were reported. Complete data were available for 3379 cases. The mean age was 64.4 years ± 10.9 (SD) and 57.8% (95% confidence interval [CI], 56.1-59.5) of the patients were women. A surgical complication was reported in 2.9% of all cases (95% CI, 2.4-3.5). The mean postoperative CDVA was 0.04 ± 0.15. logarithm of the minimum angle of resolution. A biometry prediction error (spherical equivalent) was within ±0.5 diopter in 71.8% (95% CI, 70.3-73.3) of all surgeries. Postoperative complications were reported in 3.3% (95% CI, 2.7-4.0). Patients with good preoperative CDVA had the best visual and refractive outcomes; patients with poor preoperative visual acuity had poorer outcomes. The visual and refractive outcomes of femtosecond laser-assisted cataract surgery were favorable compared with manual phacoemulsification. The outcomes were highly influenced by the preoperative visual acuity, but all preoperative CDVA groups had acceptable outcomes. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Efficiency and measurements agreement between swept-source OCT and low-coherence interferometry biometry systems.

    PubMed

    Calvo-Sanz, Jorge A; Portero-Benito, Alejandro; Arias-Puente, Alfonso

    2018-03-01

    To compare and evaluate the agreement between the measurements obtained with a swept-source optical coherence tomography (OCT)-based biometer, the IOLMaster® 700 (IOLM), and those obtained by an optical biometer based on optical low-coherence interferometry (OLCI), the Aladdin (ALD); To evaluate the ability to perform biometric measurements in those eyes with transparency alterations. Fifty-five eyes of 55 subjects were included in this study. Axial length (AL), corneal power (K, in diopters) and its astigmatism, anterior chamber depth (ACD), central corneal thickness (CCT), and lens thickness (LT) measures were obtained within both biometers, Zeiss IOLMaster 700 and Topcon Aladdin. Results were analyzed and compared using the Student's paired samples t-test, Bland-Altman analysis and intraclass correlation coefficient (ICC). Mean age was 73.12 ± 2.63 (62-89 years). The IOLM mean AL, K, and LT values did not show a statistically significant difference from ALD values and showed excellent agreement and correlation (ICC = 1.000, 0.970, 0.952). IOLM measured a lower mean ACD (-0.036 mm) and higher CCT measurements (9.296 μm). Those results were statistically different (p < 0.001 in both cases) but showed an excellent correlation coefficients (ICC = 0.994, 0.938). IOLM was able to obtain measures from all the eyes examined, while ALD did not measure in two cases with dense nuclear cataract. ALD showed spherical K measures in 7.27% of cases. Overall a quite good agreement between IOLM and ALD was found. ALD showed spherical keratometry measures in 7.27% of cases. IOLMaster 700 was more effective in obtaining AL measurements in eyes with dense cataracts.

  18. Biometry and diversity of Arabica coffee genotypes cultivated in a high density plant system.

    PubMed

    Rodrigues, W N; Tomaz, M A; Ferrão, M A G; Martins, L D; Colodetti, T V; Brinate, S V B; Amaral, J F T; Sobreira, F M; Apostólico, M A

    2016-02-11

    The present study was developed to respond to the need for an increase in crop yield in the mountain region of Caparaó (southern Espírito Santo State, Brazil), an area of traditional coffee production. This study aimed to analyze the diversity and characterize the crop yield of genotypes of Coffea arabica L. with potential for cultivation in high plant density systems. In addition, it also aimed to quantify the expression of agronomic traits in this cultivation system and provide information on the genotypes with the highest cultivation potential in the studied region. The experiment followed a randomized block design with 16 genotypes, four repetitions, and six plants per experimental plot. Plant spacing was 2.00 x 0.60 m, with a total of 8333 plants per hectare, representing a high-density cultivation system. Coffee plants were cultivated until the start of their reproductive phenological cycles and were evaluated along four complete reproductive cycles. Genotypes with high crop yield and beverage quality, short canopy, and rust resistance were selected. C. arabica genotypes showed variability in almost all characteristics. It was possible to identify different responses among genotypes grown in a high plant density cultivation system. Although the chlorophyll a content was similar among genotypes, the genotypes Acauã, Araponga MG1, Sacramento MG1, Tupi, and Catuaí IAC 44 showed a higher chlorophyll b content than the other genotypes. Among these, Sacramento MG1 also showed high leafiness and growth of vegetative structures, whereas Araponga MG1, Pau-Brasil MG1, and Tupi showed high fruit production. In addition, Araponga MG1 had also a higher and more stable crop yield over the years.

  19. The small eye phenotype in the EPIC-Norfolk eye study: prevalence and visual impairment in microphthalmos and nanophthalmos.

    PubMed

    Day, Alexander C; Khawaja, Anthony P; Peto, Tunde; Hayat, Shabina; Luben, Robert; Broadway, David C; Khaw, Kay-Tee; Foster, Paul J

    2013-01-01

    To describe the prevalence and phenotypic characteristics of small eyes in the European Prospective Investigation of Cancer (EPIC)-Norfolk Eye Study. Community cross-sectional study. East England population (Norwich, Norfolk and surrounding area). 8033 participants aged 48-92 years old from the EPIC-Norfolk Eye Study, Norfolk, UK with axial length measurements. Participants underwent a standardised ocular examination including visual acuity (LogMAR), ocular biometry, non-contact tonometry, autorefraction and fundal photography. A small eye phenotype was defined as a participant with one or both eyes with axial length of <21 mm. Prevalence of small eyes, proportion with visual impairment, demographic and biometric factors. Ninety-six participants (1.20%, 95% CI 0.98% to 1.46%) had an eye with axial length less than 21 mm, of which 74 (77%) were women. Prevalence values for shorter axial lengths were <20 mm: 0.27% (0.18% to 0.41%); <19 mm: 0.17% (0.11% to 0.29%); <18 mm: 0.14% (0.08% to 0.25%). Two participants (2.1%) had low vision (presenting visual acuity >0.48 LogMAR) and one participant was blind (>1.3 LogMAR). The prevalence of unilateral visual impairment was higher in participants with a small eye. Multiple logistic regression modelling showed presence of a small eye to be significantly associated with shorter height, lower body mass index, higher systolic blood pressure and lower intraocular pressure. The prevalence of people with small eyes is higher than previously thought. While small eyes were more common in women, this appears to be related to shorter height and lower body mass index. Participants with small eyes were more likely to be blind or to have unilateral visual impairment.

  20. Maternal exposure to diluted diesel engine exhaust alters placental function and induces intergenerational effects in rabbits.

    PubMed

    Valentino, Sarah A; Tarrade, Anne; Aioun, Josiane; Mourier, Eve; Richard, Christophe; Dahirel, Michèle; Rousseau-Ralliard, Delphine; Fournier, Natalie; Aubrière, Marie-Christine; Lallemand, Marie-Sylvie; Camous, Sylvaine; Guinot, Marine; Charlier, Madia; Aujean, Etienne; Al Adhami, Hala; Fokkens, Paul H; Agier, Lydiane; Boere, John A; Cassee, Flemming R; Slama, Rémy; Chavatte-Palmer, Pascale

    2016-07-26

    Airborne pollution is a rising concern in urban areas. Epidemiological studies in humans and animal experiments using rodent models indicate that gestational exposure to airborne pollution, in particular diesel engine exhaust (DE), reduces birth weight, but effects depend on exposure duration, gestational window and nanoparticle (NP) concentration. Our aim was to evaluate the effects of gestational exposure to diluted DE on feto-placental development in a rabbit model. Pregnant females were exposed to diluted (1 mg/m(3)), filtered DE (NP diameter ≈ 69 nm) or clean air (controls) for 2 h/day, 5 days/week by nose-only exposure (total exposure: 20 days in a 31-day gestation). DE exposure induced early signs of growth retardation at mid gestation with decreased head length (p = 0.04) and umbilical pulse (p = 0.018). Near term, fetal head length (p = 0.029) and plasma insulin and IGF1 concentrations (p = 0.05 and p = 0.019) were reduced. Placental function was also affected, with reduced placental efficiency (fetal/placental weight) (p = 0.049), decreased placental blood flow (p = 0.009) and fetal vessel volume (p = 0.002). Non-aggregated and "fingerprint" NP were observed at various locations, in maternal blood space, in trophoblastic cells and in the fetal blood, demonstrating transplacental transfer. Adult female offspring were bred with control males. Although fetoplacental biometry was not affected near term, second generation fetal metabolism was modified by grand-dam exposure with decreased plasma cholesterol (p = 0.008) and increased triglyceride concentrations (p = 0.015). Repeated daily gestational exposure to DE at levels close to urban pollution can affect feto-placental development in the first and second generation.

  1. Basil, tea tree and clove essential oils as analgesics and anaesthetics in Amphiprion clarkii (Bennett, 1830).

    PubMed

    Correia, A M; Pedrazzani, A S; Mendonça, R C; Massucatto, A; Ozório, R A; Tsuzuki, M Y

    2017-11-27

    In this study were evaluated the anaesthesia and analgesic effects of clove Eugenia caryophyllata, tea tree Melaleuca alternifolia and basil Ocimum basilicum essential oils (EO) during handling of yellowtail clownfish Amphiprion clarkii. Juveniles (3.70 ± 0.75 cm and 1.03 ± 0.50 g; mean ± standard deviation) were submitted to concentrations of 40, 50, 60, 70 and 80 µl L-1 of clove, 150, 200, 250, 300 and 350 µl L-1 of basil and 200, 300, 400, 500 and 600 µl L-1 of tea tree oils (n=10/concentration), previously defined in pilot tests. Individually and only once, fish from each treatment were placed in a glass recipient containing 1 L of seawater at a temperature of 25 °C, salinity of 35 g L-1 and the specific concentration of diluted EO (stock solution). Control (only seawater) and blank (seawater and ethanol at the highest concentration used to dilute the oils) treatments were also conducted. After reaching the stage of surgical anaesthesia, fish were submitted to biometry and a sensibility test. After that, they were transferred to clean seawater for anaesthesia recovery. The times of induction needed to reach each anaesthesia stage and anaesthesia recovery were recorded. Animals were observed for 72 hours after the procedures. All the EO provoked anaesthesia and analgesic effects in A. clarkii, but basil oil is not recommended because it caused involuntary muscle contractions and mortality in 100% and 12% of fish, respectively. The lower concentrations that promote suitable induction and recovery times are 50 µl L-1 of clove oil and 500 µl L-1 of tea tree oil. However, due to its complementary high analgesic efficiency, clove oil is recommended as the ideal anaesthetic for A. clarkii.

  2. Added value of cerebro-placental ratio and uterine artery Doppler at routine third trimester screening as a predictor of SGA and FGR in non-selected pregnancies.

    PubMed

    Rial-Crestelo, M; Martinez-Portilla, R J; Cancemi, A; Caradeux, J; Fernandez, L; Peguero, A; Gratacos, E; Figueras, Francesc

    2018-03-04

    The objective of this study is to determine the added value of cerebroplacental ratio (CPR) and uterine Doppler velocimetry at third trimester scan in an unselected obstetric population to predict smallness and growth restriction. We constructed a prospective cohort study of women with singleton pregnancies attended for routine third trimester screening (32 +0 -34 +6 weeks). Fetal biometry and fetal-maternal Doppler ultrasound examinations were performed by certified sonographers. The CPR was calculated as a ratio of the middle cerebral artery to the umbilical artery pulsatility indices. Both attending professionals and patients were blinded to the results, except in cases of estimated fetal weight < p10. The association between third trimester Doppler parameters and small for gestational age (SGA) (birth weight <10th centile) and fetal growth restriction (FGR) (birth weight below the third centile) was assessed by logistic regression, where the basal comparison was a model comprising maternal characteristics and estimated fetal weight (EFW). A total of 1030 pregnancies were included. The mean gestational age at scan was 33 weeks (SD 0.6). The addition of CPR and uterine Doppler to maternal characteristics plus EFW improved the explained uncertainty of the predicting models for SGA (15 versus 10%, p < .001) and FGR (12 versus 8%, p = .03). However, the addition of CPR and uterine Doppler to maternal characteristics plus EFW only marginally improved the detection rates for SGA (38 versus 34% for a 10% of false positives) and did not change the predictive performance for FGR. The added value of CPR and uterine Doppler at 33 weeks of gestation for detecting defective growth is poor.

  3. Timing of Gestational Weight Gain on Fetal Growth and Infant Size at Birth in Vietnam

    PubMed Central

    Young, Melissa F.; Hong Nguyen, Phuong; Addo, O. Yaw; Pham, Hoa; Nguyen, Son; Martorell, Reynaldo; Ramakrishnan, Usha

    2017-01-01

    Objective To examine the importance of timing of gestational weight gain during three time periods: 1: ≤ 20 weeks gestation), 2: 21–29 weeks) and 3: ≥ 30 weeks) on fetal growth and infant birth size. Methods Study uses secondary data from the PRECONCEPT randomized controlled trial in Thai Nguyen province, Vietnam (n = 1436). Prospective data were collected on women starting pre-pregnancy through delivery. Maternal conditional weight gain (CWG) was defined as window-specific weight gains, uncorrelated with pre-pregnancy body mass index and all prior body weights. Fetal biometry, was assessed by ultrasound measurements of head and abdomen circumferences, biparietal diameter, and femoral length throughout pregnancy. Birth size outcomes included weight and length, and head, abdomen and mid upper arm circumferences as well as small for gestational age (SGA). Adjusted generalized linear and logistic models were used to examine associations. Results Overall, three-quarters of women gained below the Institute of Medicine guidelines, and these women were 2.5 times more likely to give birth to a SGA infant. Maternal CWG in the first window (≤ 20 weeks), followed by 21–29 weeks, had the greatest association on all parameters of fetal growth (except abdomen circumference) and infant size at birth. For birth weight, a 1 SD increase CWG in the first 20 weeks had 3 times the influence compared to later CWG (≥ 30 weeks) (111 g vs. 39 g) and was associated with a 43% reduction in SGA risk (OR (95% CI): 0.57 (0.46–0.70). Conclusion There is a need to target women before or early in pregnancy to ensure adequate nutrition to maximize impact on fetal growth and birth size. Trial Registration ClinicalTrials.gov, NCT01665378 PMID:28114316

  4. Timing of Gestational Weight Gain on Fetal Growth and Infant Size at Birth in Vietnam.

    PubMed

    Young, Melissa F; Hong Nguyen, Phuong; Addo, O Yaw; Pham, Hoa; Nguyen, Son; Martorell, Reynaldo; Ramakrishnan, Usha

    2017-01-01

    To examine the importance of timing of gestational weight gain during three time periods: 1: ≤ 20 weeks gestation), 2: 21-29 weeks) and 3: ≥ 30 weeks) on fetal growth and infant birth size. Study uses secondary data from the PRECONCEPT randomized controlled trial in Thai Nguyen province, Vietnam (n = 1436). Prospective data were collected on women starting pre-pregnancy through delivery. Maternal conditional weight gain (CWG) was defined as window-specific weight gains, uncorrelated with pre-pregnancy body mass index and all prior body weights. Fetal biometry, was assessed by ultrasound measurements of head and abdomen circumferences, biparietal diameter, and femoral length throughout pregnancy. Birth size outcomes included weight and length, and head, abdomen and mid upper arm circumferences as well as small for gestational age (SGA). Adjusted generalized linear and logistic models were used to examine associations. Overall, three-quarters of women gained below the Institute of Medicine guidelines, and these women were 2.5 times more likely to give birth to a SGA infant. Maternal CWG in the first window (≤ 20 weeks), followed by 21-29 weeks, had the greatest association on all parameters of fetal growth (except abdomen circumference) and infant size at birth. For birth weight, a 1 SD increase CWG in the first 20 weeks had 3 times the influence compared to later CWG (≥ 30 weeks) (111 g vs. 39 g) and was associated with a 43% reduction in SGA risk (OR (95% CI): 0.57 (0.46-0.70). There is a need to target women before or early in pregnancy to ensure adequate nutrition to maximize impact on fetal growth and birth size. ClinicalTrials.gov, NCT01665378.

  5. Effect of data self-collection as an activating teaching method in a statistical software course in medical biometry - a pilot study.

    PubMed

    Mayer, Benjamin; Braisch, Ulrike; Meule, Marianne; Allgoewer, Andreas; Richter, Silvia; Muche, Rainer

    2018-01-01

    Background: Biostatistics is an integral part of the studies of human medicine. Students learn the basics of analyzing and interpreting study results. It is important to demonstrate the subject's relevance by means of appropriate measures to maximize learning success. We investigated whether an active involvement of students in the process of data collection may improve test performance and motivation among medical students. Methods: We conducted a pilot study comparing active involvement of students (n1=45) in the process of data collection and standard education (n2=26). All students of this pilot study participated in an observational study assessing their preferences regarding sweets or salty munchies, and students of the experimental group subsequently used this data set during the exercises throughout the semester. Primary and secondary endpoints were examination success and motivation respectively. Results: Superiority of the activating teaching method could not be demonstrated (intervention: 109.0 points (SD 8.8), control: 113.8 points (SD 6.5)). The course ratings were superior in the intervention group (median grade 1 vs. median grade 2 in the control group), although this was not a significant improvement (p=0.487). Conclusions: Biostatistics education should incorporate approaches contributing to a better understanding of learning contents. Possible reasons why this pilot study failed to prove superiority of the intervention were a lack of sample size as well as the good grades in the control group. The presented teaching concept has to be evaluated by means of a larger sample enabling more valid conclusions. Furthermore, the considered research question in the experimental group may be changed to a more relevant one for medical practice.

  6. Relationship between ultrasound estimated fetal gestational age and cerebellar appearance in healthy pregnant Nigerian women.

    PubMed

    Adeyekun, Ademola A; Orji, Michael O

    2015-01-01

    Fetal biometry by ultrasound provides reliable and important information about fetal growth and wellbeing. Evaluation of the fetal posterior fossa is useful in the assessment of neural tube-defects. Studies on normal ultrasound fetal cerebellar appearance and diameter across gestational age (GA) are scanty in the Nigerian medical literature. This study was carried out to study normal fetal cerebellar appearance and diameter at various GAs among healthy pregnant Nigerian Africans. This was a prospective study of 450 healthy singleton pregnant women between 13 and 42 weeks gestation. A curvilinear probe with a 3.5 MHz transducer of a SonoAce X6 (Medison Inc., Korea 2010) scanner was used to assess fetal transcerebellar diameter (TCD) and appearance. GA was also determined using fetal biometric parameters such as the biparietal diameter, femur length, and abdominal circumference. Fetal cerebellar appearance was correlated against GA. The cerebellar appearance was graded into: Grade I: 164 fetuses (36.4%), Grade II; 102 fetuses (22.7%) and Grade III: 184 fetuses (40.9%). Mean GA and TCD was 21 weeks and 21.2 mm for Grade I; 28 weeks and 32.6 mm for Grade II; and 35 weeks and 47.1 mm for Grade III. There was significance difference among the cerebellar grades at the GA groups and transverse cerebellar diameter (P < 0.000). There is a gradual and steady change in ultrasonographic appearance of the fetal cerebellar and diameter appearance with advancing gestation. The changes ranged from anechoic, "pair of eye glass" appearance at second trimester to relatively echogenic, "dumb-bell" appearance at early third trimester, and solid, "fan-shape" in late third trimester.

  7. Axial ultrasound B-scans of the entire eye with a 20-MHz linear array: correction of crystalline lens phase aberration by applying Fermat's principle.

    PubMed

    Mateo, Tony; Chang, Alexandre; Mofid, Yassine; Pisella, Pierre-Jean; Ossant, Frederic

    2014-11-01

    In ophthalmic ultrasonography the crystalline lens is known to be the main source of phase aberration, causing a significant decrease in resolution and distortion effects on axial B-scans. This paper proposes a computationally efficient method to correct the phase aberration arising from the crystalline lens, including refraction effects using a bending ray tracing approach based on Fermat's principle. This method is used as a basis to perform eye-adapted beamforming (BF), with appropriate focusing delays for a 128-element 20-MHz linear array in both emission and reception. Implementation was achieved on an in-house developed experimental ultrasound scanning device, the ECODERM. The proposed BF was tested in vitro by imaging a wire phantom through an eye phantom consisting of a synthetic gelatin lens anatomically set up in an appropriate liquid (turpentine) to approach the in vivo velocity ratio. Both extremes of accommodation shapes of the human crystalline lens were investigated. The performance of the developed BF was evaluated in relation to that in homogeneous medium and compared to a conventional delay-and-sum (DAS) BF and a second adapted BF which was simplified to ignore the lens refraction. Global expectations provided by our method with the transducer array are reviewed by an analysis quantifying both image quality and spatial fidelity, as well as the detrimental effects of a crystalline lens in conventional reconstruction. Compared to conventional array imaging, the results indicated a two-fold improvement in the lateral resolution, greater sensitivity and a considerable reduction of spatial distortions that were sufficient to envisage reliable biometry directly in B-mode, especially phakometry.

  8. Application of high intensity focused ultrasound for treatment of open-angle glaucoma in Indian patients.

    PubMed

    Deb-Joardar, Nilanjana; Reddy, Kasu Prasad

    2018-04-01

    The aim of this study is to assess the efficacy of ultrasound cycloplasty (UCP) in Indian patients with open angle glaucoma (OAG). A prospective interventional study was designed to treat 73 eyes of 73 patients with OAG with the EyeOP1 device equipped with six miniaturized cylindrical piezoelectric transducers. Two treatment protocols of ultrasound delivery depending on exposure time (8 s and 10 s of shot per transducer) were used. Complete ophthalmic examination, ocular biometry and anterior segment optical coherence tomography were performed preoperatively and patients were followed up at day 1, day 7 and months 1, 2, 3, 6, and 12. The primary outcome measure was "successful" intraocular pressure (IOP) control defined as IOP reduction ≥20% from baseline and IOP value >5 mm Hg at the last follow-up visit. Secondary outcomes were the occurrence of complications and mean IOP during the follow-up period. In all patients, the mean IOP reduced from 23.5 ± 3.0 mmHg before treatment to 15.7 ± 5.4 mmHg at 12 months (P < 0.05). Successful IOP control after a single procedure was 78.3% (79% and 78% in the 8 s and 10 s groups, respectively) at 12 months. Overall, the mean IOP reduction achieved in responding patients was 41% (standard deviation = 12%). Notwithstanding minor side effects such as transient pain, anterior chamber reaction, and refractive error changes, no major intraoperative or postoperative complications (severe hypotony or phthisis) were observed during the follow-up. Our short-term results reveal that UCP is a simple, safe, and noninvasive procedure which enables to significantly reduce the IOP in patients with OAG. The study results in Indian eyes corroborate findings in earlier studies on Caucasian eyes.

  9. Longitudinal study of iris concavity, corneal biomechanics, and correlations to ocular biometry in a cohort of 10- to 12-year-old UK schoolboys: 2-year follow-up data.

    PubMed

    Shah, Ameet; Lascaratos, Gerassimos; Garway-Heath, David F; Foster, Paul J; Barton, Keith

    2014-06-10

    To explore changes in iris curvature over a 2-year period. To investigate associations between iris curvature and ocular biometric parameters. To explore relationships between a number of nonocular measurements and ocular biometric parameters. Schoolboys enrolled 2 years previously were invited to return for anterior segment optical coherence tomography, corneal hysteresis (CH), corneal resistance factor (CRF), and axial biometric measurements. Refractive error was assessed and measures of height, weight, waist circumference, digit ratio, and percentage body fat taken. Mean spherical equivalent refraction reduced by 0.76 diopters and mean iris concavity, defined as a measurement of less than or equal to -0.1 mm, increased by 0.018 mm at distance fixation and 0.04 mm on accommodation. Compared with 2 years previously, the prevalence of iris concavity increased from 24% to 32% on distance fixation and from 65% to 84% on accommodation. Variables significantly associated with nonaccommodating iris curvature were anterior chamber depth (ACD, P = 0.029) and mean scleral spur angle (P = 0.0001). Variables significantly associated with accommodating iris curvature were ACD (P = 0.02), lens vault (P = 0.047), and scleral spur angle (P < 0.0001). Significant association was again found between CH and accommodating spur-to-spur distance (R(2) = 0.13, P = 0.007). Iris concavity was more prevalent in this cohort of schoolboys than 2 years earlier. The degree of concavity remains related to ACD and lens vault. The association between spur-to-spur distance and CH was similar at baseline and after 2 years. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  10. Cassava flour slurry as a low-cost alternative to commercially available gel for obstetrical ultrasound: a blinded non-inferiority trial comparison of image quality.

    PubMed

    Aziz, A; Dar, P; Hughes, F; Solorzano, C; Muller, M M; Salmon, C; Salmon, M; Benfield, N

    2018-01-12

    To evaluate the quality of ultrasound images obtained with cassava flour slurry (CFS) compared with conventional gel in order to determine objectively whether CFS could be a true low-cost alternative. Blinded non-inferiority trial. Obstetrical ultrasound unit in an academic medical centre. Women with a singleton pregnancy, undergoing anatomy ultrasounds. Thirty pregnant women had standard biometry measures obtained with CFS and conventional gel. Images were compared side-by-side in random order by two blinded sonologists and rated for image resolution, detail and total image quality using a 10-cm visual analogue scale. Ratings were compared using paired t-tests. Participant and sonographer experience was measured using five-point Likert scales. Image resolution, detail, and total image quality. Participant experience of gel regarding irritation, messiness, and ease of removal. We found no significant difference between perceived image quality obtained with CFS (mean = 6.2, SD = 1.2) and commercial gel (mean = 6.4, SD = 1.2) [t (28) = -1.1; P = 0.3]. Images were not rated significantly differently for either reviewer in any measure, any standardized image or any view of a specific anatomic structure. All five sonographers rated CFS as easy to obtain clear images and easy for patient and machine cleanup. Only one participant reported itching with CFS. CFS produces comparable image quality to commercial ultrasound gel. The dissemination of these results and the simple CFS recipe could significantly increase access to ultrasound for screening, monitoring and diagnostic purposes in resource-limited settings. This study was internally funded by our department. Low-cost homemade cassava flour slurry creates images equal to commercial ultrasound gel, improving access. © 2018 Royal College of Obstetricians and Gynaecologists.

  11. Effects of Birth Weight on Anterior Segment Measurements in Full-Term Children Without Low Birth Weight by Dual-Scheimpflug Analyzer.

    PubMed

    Yeter, Volkan; Aritürk, Nurşen; Bİrİncİ, Hakki; Süllü, Yüksel; Güngör, İncİ

    2015-10-01

    To evaluate the effects of birth weight on ocular anterior segment parameters in full-term children without low birth weight using the Galilei Dual-Scheimpflug Analyzer. Retrospective cohort study. The right eyes from 110 healthy children, 3-6 years of age, were scanned with the Galilei Dual-Scheimpflug Analyzer. A total of 78 eyes were measured in full-term children with birth weight of >2500 g. Central, paracentral, pericentral, and the thinnest corneal thicknesses; anterior and posterior keratometry (average, steep, flat); axial curvatures; asphericity of cornea; anterior chamber depth and volume; and iridocorneal angle values were measured. Axial length, lens thickness, and vitreous length were obtained by ultrasound biometry. The mean age of children was 55.86 ± 12.52 (mean ± SD) months. Mean birth weight and gestational age were 3426.3 ± 545 g and 39.4 ± 1.2 weeks, respectively. Although lens thickness, vitreous length, axial length, and anterior chamber volume were moderately correlated with birth weight (P < .05), there was no relationship between birth weight and anterior chamber depth. With the exception of pericentral corneal thickness, all regions of corneal thicknesses were correlated with birth weight (P < .05). Birth weight was negatively correlated with anterior curvature (P < .05) and had no relationship to posterior curvature. While central and paracentral axial curvatures correlated with birth weight (P < .05), pericentral axial curvature did not. Preschoolers who were born heavier had thicker cornea and lens, longer axial length, and flatter corneal curve. The thicknesses and axial curves of central cornea within 7 mm may be particularly associated with birth weight. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. High-hyperopia database, part I: clinical characterisation including morphometric (biometric) differentiation of posterior microphthalmos from nanophthalmos

    PubMed Central

    Relhan, N; Jalali, S; Pehre, N; Rao, H L; Manusani, U; Bodduluri, L

    2016-01-01

    Purpose To characterise and differentiate posterior microphthalmos (PM) and nanophthalmos (NO) using morphometric parameters. Patients and methods Consecutive case database of patients with hyperopia >+7.00 D sphere was analysed retrospectively for clinical and biometric characterisation. Thirty-eight consecutive high-hyperopic subjects (75 eyes) with axial lengths <20.5 mm underwent uniform comprehensive ocular evaluation. Twenty-five subjects were diagnosed as PM and 13 as NO based on the horizontal corneal diameter. Parameters analysed included visual acuity, refraction, horizontal corneal diameter, anterior chamber depth, lens thickness, axial length, fundus changes, and associated ocular pathology. Primary outcome measures: ocular biometry difference between PM and NO. Secondary outcome measures: differences in associated ocular pathologies between PM and NO. Results Hyperopia ranged from +7 to +17 D and was similar in the two groups. Lens thickness was statistically more in NO than in PM group (4.53±0.75 mm vs 3.82±0.48 mm, P <0.001), whereas anterior chamber depth was more in the PM than in NO group (3.26±0.36 mm, vs 2.59±0.37 mm, P<0.001). NO had higher association with angle-closure glaucoma (66.7% vs 0%) and pigmentary retinopathy (38.5 vs 8.0%) but lesser association with macular folds (0% vs 24%) as compared with PM. NO was associated with poorer visual acuity. Conclusion PM and NO have significant differences in lens thickness, anterior chamber depth, prevalence of glaucoma, pigmentary retinopathy, macular pathology, and visual acuity while being similar in hyperopic refraction. PMID:26493039

  13. Oligo-Miocene foraminiferal record (Miogypsinidae, Lepidocyclinidae and Nummulitidae) from the Western Taurides (SW Turkey): Biometry and implications for the regional geology

    NASA Astrophysics Data System (ADS)

    Özcan, Ercan; Less, György; Báldi-Beke, Mária; Kollányi, Katalin; Acar, Ferhat

    2009-05-01

    The marine Oligo-Miocene units of western Taurides, deposited under different tectonic regimes (in Bey Dağları platform in foreland and coeval sequences in hinterland), were studied to establish a high-resolution biostratigraphic framework. Biometric study of the full spectrum of larger foraminifera in a regional scale allowed us correlating them with the shallow benthic zonation (SBZ) system introduced by [Cahuzac, B., Poignant, A., 1997. Essai de biozonation de l'Oligo-Miocène dans les bassins européens à l'aide des grands foraminifères néritiques. Bulletin de la Société géologique de France 168, 155-169], and to determine the ages of these sites on zonal precision for the first time. In correlating these assemblages to standard shallow benthic zones, planktonic data were also used whenever possible. Taxa, classified under the genera Nummulites, Miogypsina, Miolepidocyclina, Nephrolepidina, Eulepidina, Heterostegina, Operculina and Cycloclypeus (?) and their assemblages, closely resemble to the fauna described from European basins. These groups characterize the SBZ 22B to 25 zones referring to a time interval from early Chattian to Burdigalian. However, a main gap in late Chattian (SBZ 23) and in early part of the Aquitanian (SBZ 24) is also recorded in the platform succession. In the meantime, rare Eulepidina in the Burdigalian levels suggest a clear Indo-Pacific influence. Based on the discovery of early Chattian (SBZ 22B) deposits (previously mapped under Eocene/Miocene units), the Oligo-Miocene stratigraphy of the Bey Dağları platform is also revised. A more precise chronology for regional Miocene transgression is presented based on the miogypsinid evolutionary scale.

  14. Latest Early Pleistocene remains of Lynx pardinus (Carnivora, Felidae) from the Iberian Peninsula: Taxonomy and evolutionary implications

    NASA Astrophysics Data System (ADS)

    Boscaini, Alberto; Alba, David M.; Beltrán, Juan F.; Moyà-Solà, Salvador; Madurell-Malapeira, Joan

    2016-07-01

    The Iberian lynx (Lynx pardinus) is a critically endangered felid that, during the last fifty years, has been subject to an intensive conservation program in an attempt to save it from extinction. This species is first recorded at ca. 1.7-1.6 Ma (late Villafranchian, late Early Pleistocene) in NE Iberian Peninsula, roughly coinciding with the large faunal turnover that occurred around the middle to late Villafranchian boundary. Here we describe the largest collection of L. pardinus remains available to date from the Iberian late Early Pleistocene (Epivillafranchian), including localities from the Vallparadís Section (Vallès-Penedès Basin, NE Iberian Peninsula) and Cueva Victoria (Cartagena, SE Iberian Peninsula). The morphology and biometry of the studied material attests to the widespread occurrence of L. pardinus in the Mediterranean coast of the Iberian Peninsula since the latest Early Pleistocene, i.e., about 0.5 million years earlier than it was generally accepted (i.e., at the beginning of the Middle Pleistocene). Based on the features observed in the large sample studied in this paper, we conclude that Lynx spelaeus is a junior synonym of L. pardinus and further propose to assign all the Epivillafranchian and younger fossil lynxes from SW Europe to the extant species L. pardinus. Due to the arrival of the Eurasian lynx (Lynx lynx) into Europe at the beginning of the Late Pleistocene, the attribution of specimens younger than MIS 5e to either this species or L. pardinus solely on morphological grounds has proven equivocal. Here we discuss the main diagnostic features of both species of European lynxes and further review their evolutionary history and paleobiogeography throughout the Pleistocene.

  15. A method for profiling biometric changes during disaccommodation.

    PubMed

    Alderson, Alison; Davies, Leon N; Mallen, Edward A H; Sheppard, Amy L

    2012-05-01

    To demonstrate the application of low-coherence reflectometry to the study of biometric changes during disaccommodation responses in human eyes after cessation of a near task and to evaluate the effect of contact lenses on low-coherence reflectometry biometric measurements. Ocular biometric parameters of crystalline lens thickness (LT) and anterior chamber depth (ACD) were measured with the LenStar device during and immediately after a 5 D accommodative task in 10 participants. In a separate trial, accommodation responses were recorded with a Shin-Nippon WAM-5500 optometer in a subset of two participants. Biometric data were interleaved to form a profile of post-task anterior segment changes. In a further experiment, the effect of soft contact lenses on LenStar measurements was evaluated in 15 participants. In 10 adult participants, increased LT and reduced ACD was seen during the 5 D task. Post-task, during fixation of a 0 D target, a profile of the change in LT and ACD against time was observed. In the two participants with accommodation data (one a sufferer of nearwork-induced transient myopia and other a non-sufferer), the post-task changes in refraction compared favorably with the interleaved LenStar biometry data. The insertion of soft contact lenses did not have a significant effect on LenStar measures of ACD or LT (mean change: -0.007 mm, p = 0.265 and + 0.001 mm, p = 0.875, respectively). With the addition of a relatively simple stimulus modification, the LenStar instrument can be used to produce a profile of post-task changes in LT and ACD. The spatial and temporal resolution of the system is sufficient for the investigation of nearwork-induced transient myopia from a biometric viewpoint. LenStar measurements of ACD and LT remain valid after the fitting of soft contact lenses.

  16. Inter-observer variability in fetal biometric measurements.

    PubMed

    Kilani, Rami; Aleyadeh, Wesam; Atieleh, Luay Abu; Al Suleimat, Abdul Mane; Khadra, Maysa; Hawamdeh, Hassan M

    2018-02-01

    To evaluate inter-observer variability and reproducibility of ultrasound measurements for fetal biometric parameters. A prospective cohort study was implemented in two tertiary care hospitals in Amman, Jordan; Prince Hamza Hospital and Albashir Hospital. 192 women with a singleton pregnancy at a gestational age of 18-36 weeks were the participants in the study. Transabdominal scans for fetal biometric parameter measurement were performed on study participants from the period of November 2014 to March 2015. Women who agreed to participate in the study were administered two ultrasound scans for head circumference, abdominal circumference and femur length. The correlation coefficient was calculated. Bland-Altman plots were used to analyze the degree of measurement agreement between observers. Limits of agreement ± 2 SD for the differences in fetal biometry measurements in proportions of the mean of the measurements were derived. Main outcome measures examine the reproducibility of fetal biometric measurements by different observers. High inter-observer inter-class correlation coefficient (ICC) was found for femur length (0.990) and abdominal circumference (0.996) where Bland-Altman plots showed high degrees of agreement. The highest degrees of agreement were noted in the measurement of abdominal circumference followed by head circumference. The lowest degree of agreement was found for femur length measurement. We used a paired-sample t-test and found that the mean difference between duplicate measurements was not significant (P > 0.05). Biometric fetal parameter measurements may be reproducible by different operators in the clinical setting with similar results. Fetal head circumference, abdominal circumference and femur length were highly reproducible. Large organized studies are needed to ensure accurate fetal measurements due to the important clinical implications of inaccurate measurements. Copyright © 2018. Published by Elsevier B.V.

  17. Growth pattern differences of captive born Antillean manatee (Trichechus manatus) calves and those rescued in the Brazilian northeastern coast.

    PubMed

    Borges, João Carlos Gomes; Freire, Augusto Carlos da Bôaviagem; Attademo, Fernanda Loffler Niemeyer; Serrano, Inês de Lima; Anzolin, Daiane Garcia; de Carvalho, Paulo Sérgio Martins; Vergara-Parente, Jociery Einhardt

    2012-09-01

    The aim of this work was to analyze whether there are differences between the development pattern of Antillean manatee (Trichechus manatus) calves born in captivity and those rescued and kept under rehabilitation. Biometrics data were collected from 1990 to 2010 from 38 calves, 29 of which still had the remnants of the umbilical cord and had been rescued from the Brazilian northeastern coastline (Group I), and nine individuals that were born in captivity and remained with their mothers (Group II). Among the measures obtained through biometry, the total length and weight of the animal were recorded. Given that the breastfeeding of calves occurs approximately until the age of 2 yr, data obtained until the 24th month of life of each individual were evaluated. An average increase in weight of 53.50 +/- 38.54 kg (mean +/- standard deviation [SD]) was detected in Group I and a gain of 106.87 +/- 47.21 kg (mean +/- SD) in Group II. From months 13 to 24, no significant difference in the weight increment was observed. A similar pattern occurred with regard to the increase in the overall length during the first year, where animals from Group I grew 34.81 +/- 17.94 cm (mean +/- SD) and from Group II grew 83.83 +/- 28.21 cm, a statistically significant difference. The growth was not significantly different from 13 to 24 mo. The results found in this study identified the need for a review of the nutritional diet offered to orphaned calves rescued and kept in captivity. The results also support the need for a better adequacy of facilities for these animals as a way to encourage the management strategies adopted for manatee calves maintained in captivity.

  18. Comparative Efficacy of the New Optical Biometer on Intraocular Lens Power Calculation (AL-Scan versus IOLMaster).

    PubMed

    Ha, Ahnul; Wee, Won Ryang; Kim, Mee Kum

    2018-05-15

    To evaluate the agreement in axial length (AL), keratometry, and anterior chamber depth measurements between AL-Scan and IOLMaster biometers and to compare the efficacy of the AL-Scan on intraocular lens (IOL) power calculations and refractive outcomes with those obtained by the IOLMaster. Medical records of 48 eyes from 48 patients who underwent uneventful phacoemulsification and IOL insertion were retrospectively reviewed. One of the two types of monofocal aspheric IOLs were implanted (Tecnis ZCB00 [Tecnis, n = 34] or CT Asphina 509M [Asphina, n = 14]). Two different partial coherence interferometers measured and compared AL, keratometry (2.4 mm), anterior chamber depth, and IOL power calculations with SRK/T, Hoffer Q, Holladay2, and Haigis formulas. The difference between expected and actual final refractive error was compared as refractive mean error (ME), refractive mean absolute error (MAE), and median absolute error (MedAE). AL measured by the AL-Scan was shorter than that measured by the IOLMaster (p = 0.029). The IOL power of Tecnis did not differ between the four formulas; however, the Asphina measurement calculated using Hoffer Q for the AL-Scan was lower (0.28 diopters, p = 0.015) than that calculated by the IOLMaster. There were no statistically significant differences between the calculations by MAE and MedAE for the four formulas in either IOL. In SRK/T, ME in Tecnis-inserted eyes measured by AL-Scan showed a tendency toward myopia (p = 0.032). Measurement by AL-Scan provides reliable biometry data and power calculations compared to the IOLMaster; however, refractive outcomes of Tecnis-inserted eyes by AL-Scan calculated using SRK/T can show a slight myopic tendency. © 2018 The Korean Ophthalmological Society.

  19. Coccolithophore responses to environmental variability in the South China Sea: species composition and calcite content

    NASA Astrophysics Data System (ADS)

    Jin, Xiaobo; Liu, Chuanlian; Poulton, Alex J.; Dai, Minhan; Guo, Xianghui

    2016-08-01

    Coccolithophore contributions to the global marine carbon cycle are regulated by the calcite content of their scales (coccoliths) and the relative cellular levels of photosynthesis and calcification rates. All three of these factors vary between coccolithophore species and with response to the growth environment. Here, water samples were collected in the northern basin of the South China Sea (SCS) during summer 2014 in order to examine how environmental variability influenced species composition and cellular levels of calcite content. Average coccolithophore abundance and their calcite concentration in the water column were 11.82 cells mL-1 and 1508.3 pg C mL-1, respectively, during the cruise. Water samples can be divided into three floral groups according to their distinct coccolithophore communities. The vertical structure of the coccolithophore community in the water column was controlled by the trophic conditions, which were regulated by mesoscale eddies across the SCS basin. The evaluation of coccolithophore-based calcite in the surface ocean also showed that three key species in the SCS (Emiliania huxleyi, Gephyrocapsa oceanica, Florisphaera profunda) and other larger, numerically rare species made almost equal contributions to total coccolith-based calcite in the water column. For Emiliania huxleyi biometry measurements, coccolith size positively correlated with nutrients (nitrate, phosphate), and it is suggested that coccolith length is influenced by light and nutrients through the regulation of growth rates. Larger-sized coccoliths were also linked statistically to low pH and calcite saturation states; however, it is not a simple cause and effect relationship, as carbonate chemistry was strongly co-correlated with the other key environmental factors (nutrients, light).

  20. Determination of morphological, biometric and biochemical susceptibilities in healthy Eurasier dogs with suspected inherited glaucoma.

    PubMed

    Boillot, Thomas; Rosolen, Serge G; Dulaurent, Thomas; Goulle, Frédéric; Thomas, Philippe; Isard, Pierre-François; Azoulay, Thierry; Lafarge-Beurlet, Stéphanie; Woods, Mike; Lavillegrand, Sylvie; Ivkovic, Ivana; Neveux, Nathalie; Sahel, José-Alain; Picaud, Serge; Froger, Nicolas

    2014-01-01

    In both humans and dogs, the primary risk factor for glaucoma is high intraocular pressure (IOP), which may be caused by iridocorneal angle (ICA) abnormalities. Oxidative stress has also been implicated in retinal ganglion cell damage associated with glaucoma. A suspected inherited form of glaucoma was recently identified in Eurasier dogs (EDs), a breed for which pedigrees are readily available. Because of difficulties in assessing ICA morphology in dogs with advanced glaucoma, we selected a cohort of apparently healthy dogsfor the investigation of ICA morphological status, IOP and plasma concentrations of oxidative stress biomarkers. We aimed to establish correlations between these factors, to identify predictive markers of glaucoma in this dog breed. A cohort of 28 subjects, volunteered for inclusion by their owners, was selected by veterinary surgeons. These dogs were assigned to four groups: young males, young females (1-3 years old), adult males and adult females (4-8 years old). Ocular examination included ophthalmoscopy, tonometry, gonioscopy, biometry and ultrasound biomicroscopy (UBM), and the evaluation of oxidative stress biomarkers consisting of measurements of plasma glutathione peroxidase (GP) activity and taurine and metabolic precursor (methionine and cysteine) concentrations in plasma. The prevalence of pectinate ligament abnormalities was significantly higher in adult EDs than in young dogs. Moreover, in adult females, high IOP was significantly correlated with a short axial globe length, and a particularly large distance between Schwalbe's line and the anterior lens capsule. GP activity levels were significantly lower in EDs than in a randomized control group of dogs, and plasma taurine concentrations were higher. Hence, ICA abnormalities were associated with weaker antioxidant defenses in EDs, potentially counteracted by higher plasma taurine concentrations. This study suggests that EDs may constitute an appropriate canine model for the development of glaucoma. This cohort will be used as a sentinel for longitudinal monitoring.

  1. Posterior corneal astigmatism in refractive lens exchange surgery.

    PubMed

    Rydström, Elin; Westin, Oscar; Koskela, Timo; Behndig, Anders

    2016-05-01

    To assess the anterior, posterior and total corneal spherical and astigmatic powers in patients undergoing refractive lens exchange (RLE) surgery. In 402 consecutive patients planned for RLE at Koskelas Eye Clinic, Luleå, Sweden, right eye data from pre- and postoperative subjective refraction, preoperative IOLMaster(®) biometry and Pentacam HR(®) measurements were collected. Postoperative Pentacam HR(®) data were collected for 54 of the patients. The spherical and astigmatic powers of the anterior and posterior corneal surfaces and for the total cornea were assessed and compared, and surgically, induced astigmatism was calculated using vector analysis. The spherical power of the anterior corneal surface was 48.18 ± 1.69D with an astigmatic power of 0.83 ± 0.54D. The corresponding values for the posterior surface were -6.05 ± 2,52D and 0.26 ± 0.15D, respectively. The total corneal spherical power calculated with ray tracing was 42.47 ± 2.89D with a 0.72 ± 0.48D astigmatic power, and the corresponding figures obtained by estimating the posterior corneal surface were 43.25 ± 1.51D (p < 0.001) with a 0.75 ± 0.49D astigmatic power (p = 0.003). In eyes with anterior astigmatism with-the-rule, the total corneal astigmatism is overestimated if the posterior corneal surface is estimated; in eyes, with against-the-rule astigmatism it is underestimated. Had the posterior corneal surface been measured in this material, 14.7% of the patients would have received a spheric instead of a toric IOL, or vice versa. Estimating the posterior corneal surface in RLE patients leads to systematic measurement errors that can be reduced by measuring the posterior surface. Such an approach can potentially increase the refractive outcome accuracy in RLE surgery. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  2. Light intensity modulates corneal power and refraction in the chick eye exposed to continuous light.

    PubMed

    Cohen, Yuval; Belkin, Michael; Yehezkel, Oren; Avni, Isaac; Polat, Uri

    2008-09-01

    Continuous exposure of chicks to light was shown to result in severe hyperopia, accompanied by anterior segment changes, such as severe corneal flattening. Since rearing chicks in complete darkness results only in mild hyperopia and minor changes in corneal curvature, we hypothesized that light intensity may play a role in the development of refractive changes under continuous light illumination. To test this hypothesis, we examined the effects of rearing chicks under various continuous light intensities. More specifically, we investigated the refractive parameters of the chicks' eyes, and avoided light cycling effects on ocular development. To this end, thirty-eight chicks were reared under 24-h incandescent illumination, at three different light intensities: 10,000 lux (n=13), 500 lux (n=12), and 50 lux (n=13). Their eyes underwent repeated retinoscopy, keratometry, and ultrasound biometry, as well as caliper measurements of enucleated eyes. Both refraction and corneal refractive power were found to be correlated with light intensity. On day 90 after hatching, exposure to light intensities of 10,000, 500, and 50 lux resulted in hyperopia of +11.97+/-3.7 (mean+/-SD) +7.9+/-4.08 and +0.63+/-3.61 diopters (D), respectively. Under those intensities, corneal refractive power was 46.10+/-3.62, 49.72+/-4.16, and 56.88+/-4.92D, respectively. Axial length did not differ significantly among the groups. The vitreous chamber was significantly deeper in the high than in the low-intensity groups. Thus, during the early life of chicks exposed to continuous lighting, light intensity affects the vitreous chamber depth as well as the anterior segment parameters, most notably the cornea. The higher the intensity, the more severe was the corneal flattening observed and the hyperopia that developed, whereas continuous illumination at low intensities resulted in emmetropia. Thus, light intensity is an important factor that should be taken into account when studying refractive development.

  3. Patterns of NPP, GPP, Respiration and NEP During Boreal Forest Succession

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goulden, Michael L.; McMillan, Andrew; Winston, Greg

    2010-12-15

    We deployed a mesonet of year-round eddy covariance towers in boreal forest stands that last burned in ~1850, ~1930, 1964, 1981, 1989, 1998, and 2003 to understand how CO2 exchange changes during secondary succession.The strategy of using multiple methods, including biometry and micrometeorology, worked well. In particular, the three independent measures of NEP during succession gave similar results. A stratified and tiered approach to deploying eddy covariance systems that combines many lightweight and portable towers with a few permanent ones is likely to maximize the science return for a fixed investment. The existing conceptual models did a good job ofmore » capturing the dominant patterns of NPP, GPP, Respiration and NEP during succession. The initial loss of carbon following disturbance was neither as protracted nor large as predicted. This muted response reflects both the rapid regrowth of vegetation following fire and the prevalence of standing coarse woody debris following the fire, which is thought to decay slowly. In general, the patterns of forest recovery from disturbance should be expected to vary as a function of climate, ecosystem type and disturbance type. The NPP decline at the older stands appears related to increased Rauto rather than decreased GPP. The increase in Rauto in the older stands does not appear to be caused by accelerated maintenance respiration with increased biomass, and more likely involves increased allocation to fine root turnover, root metabolism, alternative forms of respiration, mycorrhizal relationships, or root exudates, possibly associated with progressive nutrient limitation. Several studies have now described a similar pattern of NEP following boreal fire, with 10-to-15 years of modest carbon loss followed by 50-to-100 years of modest carbon gain. This trend has been sufficiently replicated and evaluated using independent techniques that it can be used to quantify the likely effects of changes in boreal fire frequency and stand age structure on regional carbon balance.« less

  4. The value of repeating studies and multiple controls: replicated 28-day growth studies of rainbow trout exposed to clofibric acid.

    PubMed

    Owen, Stewart F; Huggett, Duane B; Hutchinson, Thomas H; Hetheridge, Malcolm J; McCormack, Paul; Kinter, Lewis B; Ericson, Jon F; Constantine, Lisa A; Sumpter, John P

    2010-12-01

    Two studies to examine the effect of waterborne clofibric acid (CA) on growth-rate and condition of rainbow trout were conducted using accepted regulatory tests (Organisation for Economic Co-operation and Development [OECD] 215). The first study (in 2005) showed significant reductions after 21 d of exposure (21-d growth lowest-observed-effect concentration [LOEC] = 0.1 µg/L, 21-d condition LOEC = 0.1 µg/L) that continued to 28 d. Growth rate was reduced by approximately 50% (from 5.27 to 2.67% per day), while the condition of the fish reduced in a concentration-dependant manner. Additionally, in a concentration-dependent manner, significant changes in relative liver size were observed, such that increasing concentrations of CA resulted in smaller livers after 28-d exposure. A no-observed-effect concentration (NOEC) was not achieved in the 2005 study. An expanded second study (in 2006) that included a robust bridge to the 2005 study, with four replicate tanks of eight individual fish per concentration, did not repeat the 2005 findings. In the 2006 study, no significant effect on growth rate, condition, or liver biometry was observed after 21 or 28 d (28-d growth NOEC = 10 µg/L, 28-d condition NOEC = 10 µg/L), contrary to the 2005 findings. We do not dismiss either of these findings and suggest both are relevant and stand for comparison. However, the larger 2006 study carries more statistical power and multiple-tank replication, so probably produced the more robust findings. Despite sufficient statistical power in each study, interpretation of these and similar studies should be conducted with caution, because much significance is placed on the role of limited numbers of individual and tank replicates and the influence of control animals. Copyright © 2010 SETAC.

  5. New trends in intraocular lens imaging

    NASA Astrophysics Data System (ADS)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the eye in near vision. Finally, we present a theoretical approach that considers the modification of less conventional ocular parameters to compensate for possible refractive errors after the IOL implant.

  6. Evaluation of fetal anthropometric measures to predict the risk for shoulder dystocia.

    PubMed

    Burkhardt, T; Schmidt, M; Kurmanavicius, J; Zimmermann, R; Schäffer, L

    2014-01-01

    To evaluate the quality of anthropometric measures to improve the prediction of shoulder dystocia by combining different sonographic biometric parameters. This was a retrospective cohort study of 12,794 vaginal deliveries with complete sonographic biometry data obtained within 7 days before delivery. Receiver-operating characteristics (ROC) curves of various combinations of the biometric parameters, namely, biparietal diameter (BPD), occipitofrontal diameter (OFD), head circumference, abdominal diameter (AD), abdominal circumference (AC) and femur length were analyzed. The influences of independent risk factors were calculated and their combination used in a predictive model. The incidence of shoulder dystocia was 1.14%. Different combinations of sonographic parameters showed comparable ROC curves without advantage for a particular combination. The difference between AD and BPD (AD - BPD) (area under the curve (AUC) = 0.704) revealed a significant increase in risk (odds ratio (OR) 7.6 (95% CI 4.2-13.9), sensitivity 8.2%, specificity 98.8%) at a suggested cut-off ≥ 2.6 cm. However, the positive predictive value (PPV) was low (7.5%). The AC as a single parameter (AUC = 0.732) with a cut-off ≥ 35 cm performed worse (OR 4.6 (95% CI 3.3-6.5), PPV 2.6%). BPD/OFD (a surrogate for fetal cranial shape) was not significantly different between those with and those without shoulder dystocia. The combination of estimated fetal weight, maternal diabetes, gender and AD - BPD provided a reasonable estimate of the individual risk. Sonographic fetal anthropometric measures appear not to be a useful tool to screen for the risk of shoulder dystocia due to a low PPV. However, AD - BPD appears to be a relevant risk factor. While risk stratification including different known risk factors may aid in counseling, shoulder dystocia cannot effectively be predicted. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  7. Flight Speeds among Bird Species: Allometric and Phylogenetic Effects

    PubMed Central

    Alerstam, Thomas; Rosén, Mikael; Bäckman, Johan; Ericson, Per G. P; Hellgren, Olof

    2007-01-01

    Flight speed is expected to increase with mass and wing loading among flying animals and aircraft for fundamental aerodynamic reasons. Assuming geometrical and dynamical similarity, cruising flight speed is predicted to vary as (body mass)1/6 and (wing loading)1/2 among bird species. To test these scaling rules and the general importance of mass and wing loading for bird flight speeds, we used tracking radar to measure flapping flight speeds of individuals or flocks of migrating birds visually identified to species as well as their altitude and winds at the altitudes where the birds were flying. Equivalent airspeeds (airspeeds corrected to sea level air density, U e) of 138 species, ranging 0.01–10 kg in mass, were analysed in relation to biometry and phylogeny. Scaling exponents in relation to mass and wing loading were significantly smaller than predicted (about 0.12 and 0.32, respectively, with similar results for analyses based on species and independent phylogenetic contrasts). These low scaling exponents may be the result of evolutionary restrictions on bird flight-speed range, counteracting too slow flight speeds among species with low wing loading and too fast speeds among species with high wing loading. This compression of speed range is partly attained through geometric differences, with aspect ratio showing a positive relationship with body mass and wing loading, but additional factors are required to fully explain the small scaling exponent of U e in relation to wing loading. Furthermore, mass and wing loading accounted for only a limited proportion of the variation in U e. Phylogeny was a powerful factor, in combination with wing loading, to account for the variation in U e. These results demonstrate that functional flight adaptations and constraints associated with different evolutionary lineages have an important influence on cruising flapping flight speed that goes beyond the general aerodynamic scaling effects of mass and wing loading. PMID:17645390

  8. Effects of dietary green tea (Camellia sinensis L.) supplementation on growth performance, lipid metabolism, and antioxidant status in a sturgeon hybrid of Sterlet (Huso huso ♂ × Acipenser ruthenus ♀) fed oxidized fish oil.

    PubMed

    Hasanpour, Soleiman; Salati, Amir Parviz; Falahatkar, Bahram; Azarm, Hamid Mohammadi

    2017-10-01

    Lipid content of diet is very susceptible to oxidation, especially when stored for a long time, so for evaluating protective effects of green tea in fish received oxidized oil, this study was done. Lipid content of diet was replaced by oxidized fish oil (OFO) in 0, 50, and 100%. Green tea extract (GTE) was added to diet in three levels, 0, 5, and 100 mg/kg giving a total of nine experimental diets. Two hundred and seventy sturgeon hybrid of Sterlet (Huso huso ♀ × Acipenser ruthenus ♂) with initial weight of 212.6 ± 0.7 g after 2 weeks adaptation randomly divided in 27 fiberglass tanks with 700 L volume. Fish were fed satiated three times daily. After 6 weeks, biometry was done to evaluate growth performance and blood samples were taken for biochemical analysis. The result showed that feeding with oxidized oil had no effects on growth. However, in fish fed GTE, growth indices improved slightly. Feeding with OFO reduced serum total cholesterol, triacylglycerol, and low-density lipoprotein, while increased high density lipoprotein. Dietary GTE moderated the effects of OFO on lipid metabolism. Feeding with the OFO increased activity of serum superoxide dismutase, catalase, glutathione peroxidase, and malondialdehyde contents. In fish received both OFO and GTE, reduced activity of serum antioxidant enzymes and malondialdehyde content was recorded in compare to fish fed only OFO. According to the result of the present study, it can be argued that feeding of sturgeon hybrid of Sterlet with OFO has negative effects on lipid metabolism and antioxidant status, whereas GTE dosages used in this study have protective effects on fish from the adverse effects of oxidized oil.

  9. A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography

    PubMed Central

    Zamir, Ehud; Kong, George Y.X.; Kowalski, Tanya; Coote, Michael; Ang, Ghee Soon

    2016-01-01

    Purpose We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. Methods Two hundred sixty-six phakic eyes had lateral digital photographs taken from the temporal side, perpendicular to the visual axis, and underwent optical biometry (Nidek AL scanner). The relative anteroposterior position of the pupillary image was expressed using the ratio between: (1) lateral photographic temporal limbus to pupil distance (“E”) and (2) lateral photographic temporal limbus to cornea distance (“Z”). In the first chronological half of patients (Correlation Series), E:Z ratio (EZR) was correlated with optical biometric ACD. The correlation equation was then used to predict ACD in the second half of patients (Prediction Series) and compared to their biometric ACD for agreement analysis. Results A strong linear correlation was found between EZR and ACD, R = −0.91, R2 = 0.81. Bland-Altman analysis showed good agreement between predicted ACD using this method and the optical biometric ACD. The mean error was −0.013 mm (range −0.377 to 0.336 mm), standard deviation 0.166 mm. The 95% limits of agreement were ±0.33 mm. Conclusions Lateral digital photography and EZR calculation is a novel method to quantitatively estimate ACD, requiring minimal equipment and training. Translational Relevance EZ ratio may be employed in screening for angle closure glaucoma. It may also be helpful in outpatient medical clinic settings, where doctors need to judge the safety of topical or systemic pupil-dilating medications versus their risk of triggering acute angle closure glaucoma. Similarly, non ophthalmologists may use it to estimate the likelihood of acute angle closure glaucoma in emergency presentations. PMID:27540496

  10. Parapapillary Gamma Zone and Progression of Myopia in School Children: The Beijing Children Eye Study.

    PubMed

    Guo, Yin; Liu, Li Juan; Tang, Ping; Feng, Yi; Lv, Yan Yun; Wu, Min; Xu, Liang; Jonas, Jost B

    2018-03-01

    To assess the development and enlargement of the parapapillary gamma zone in school children. This school-based prospective longitudinal study included Chinese children attending grade 1 in 2011 and returning for yearly follow-up examinations until 2016. These examinations consisted of a comprehensive ocular examination with biometry and color fundus photographs. The parents underwent a standardized interview. The parapapillary gamma zone was defined as the area with visible sclera at the temporal optic disc margin, and the optic disc itself was measured on fundus photographs. The study included 294 children (mean age in 2016, 11.4 ± 0.5 years [range, 10-13 years]; mean axial length, 24.1 ± 1.1 mm [range, 21.13-27.29 mm]). In multivariate analysis, larger increases in the gamma zone area during the study period were correlated (coefficient of determination for bivariate analysis [r2], r2 = 0.69) with larger increases in the vertical-to-horizontal disc diameter ratios (P < 0.001; standardized regression coefficient beta [beta], 0.53; nonstandardized regression coefficient B [B], 4.05; 95% confidence intervals [CI], 3.37-4.73), larger axial elongation (P < 0.001; beta, 0.32; B, 0.37; 95% CI, 0.26-0.47), a larger vertical disc diameter at baseline (P < 0.001; beta, 0.22; B, 0.98; 95% CI, 0.62-1.33), a larger gamma zone area at baseline (P < 0.001; beta, 0.14; B, 0.41; 95% CI, 0.17-0.64), and more time spent indoors studying (P = 0.015; beta, 0.10; B, 0.09; 95% CI, 0.02-0.17). The development and enlargement of the gamma zone in the temporal parapapillary region were associated with an optic disc rotation around the vertical disc axis as indicated by an increasing vertical-to-horizontal disc diameter ratio. These morphologic findings fit with the notion of a backward pull of the temporal peripapillary sclera through the optic nerve dura mater in axially elongated eyes.

  11. WHO multicentre study for the development of growth standards from fetal life to childhood: the fetal component

    PubMed Central

    2014-01-01

    Background In 2006 WHO presented the infant and child growth charts suggested for universal application. However, major determinants for perinatal outcomes and postnatal growth are laid down during antenatal development. Accordingly, monitoring fetal growth in utero by ultrasonography is important both for clinical and scientific reasons. The currently used fetal growth references are derived mainly from North American and European population and may be inappropriate for international use, given possible variances in the growth rates of fetuses from different ethnic population groups. WHO has, therefore, made it a high priority to establish charts of optimal fetal growth that can be recommended worldwide. Methods This is a multi-national study for the development of fetal growth standards for international application by assessing fetal growth in populations of different ethnic and geographic backgrounds. The study will select pregnant women of high-middle socioeconomic status with no obvious environmental constraints on growth (adequate nutritional status, non-smoking), and normal pregnancy history with no complications likely to affect fetal growth. The study will be conducted in centres from ten developing and industrialized countries: Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand. At each centre, 140 pregnant women will be recruited between 8 + 0 and 12 + 6 weeks of gestation. Subsequently, visits for fetal biometry will be scheduled at 14, 18, 24, 28, 32, 36, and 40 weeks (+/− 1 week) to be performed by trained ultrasonographers. The main outcome of the proposed study will be the development of fetal growth standards (either global or population specific) for international applications. Discussion The data from this study will be incorporated into obstetric practice and national health policies at country level in coordination with the activities presently conducted by WHO to implement the use of the Child Growth Standards. PMID:24886101

  12. The Effects of Fetal Gender on Maternal and Fetal Insulin Resistance.

    PubMed

    Walsh, Jennifer M; Segurado, Ricardo; Mahony, Rhona M; Foley, Michael E; McAuliffe, Fionnuala M

    2015-01-01

    Gender plays a role in the development of a number of cardiovascular and metabolic diseases and it has been suggested that females may be more insulin resistant in utero. We sought to assess the relationship between infant gender and insulin resistance in a large pregnancy cohort. This is a secondary analysis of a cohort from the ROLO randomized control trial of low GI diet in pregnancy. Serum insulin, glucose and leptin were measured in early pregnancy and at 28 weeks. At delivery cord blood C-peptide and leptin were measured. A comparison of maternal factors, fetal biometry, insulin resistance and leptin was made between male and female offspring. A multivariate regression model was built to account for the possible effects of maternal BMI, birthweight and original study group assignment on findings. A total of 582 women were included in this secondary analysis, of whom 304 (52.2%) gave birth to male and 278 (47.8%) gave birth to female infants. Compared to male infants at birth, female infants were significantly lighter, (3945 ± 436 vs. 4081± 549g, p<0.001), shorter in length (52.36 ± 2.3 vs. 53.05 ± 2.4cm, p<0.001) and with smaller head circumferences (35.36 ± 1.5 vs. 36.10 ± 1.1cm, p<0.001) than males. On multiple regression analysis, women pregnant with female fetuses were less insulin resistant in early pregnancy, i.e. had lower HOMA indices (B = -0.19, p = 0.01). Additionally female fetuses had higher concentrations of both cord blood leptin and C-peptide at birth when compared to male offspring (B = 0.38, p<0.001 and B = 0.31, p = 0.03 respectively). These findings suggest gender is a risk factor for insulin resistance in-utero. Additionally, carrying a female fetus decreases the risk of insulin resistance in the mother, from as early as the first trimester.

  13. Tree growth rates in an Amazonian evergreen forest: seasonal patterns and correlations with leaf phenology

    NASA Astrophysics Data System (ADS)

    Wu, J.; Silva Campos, K.; Prohaska, N.; Ferreira, M. L.; Nelson, B. W.; Saleska, S. R.; da Silva, R.

    2014-12-01

    Metabolism and phenology of tropical forests significantly influence global dynamics of climate, carbon and water. However, there is still lack of mechanistic understanding of the controls on tropical forest metabolism, particularly at individual tree level. In this study, we are interested in investigating (1) what is the seasonal pattern of woody growth for tropical trees and (2) what is the mechanistic controls onwoody growth at individual level?To explore the above questions,we use two data sources from an evergreen tropical forest KM67 site (near Santarem, Brazil). They are: (1) image time series from a tower mounted RGB imaging system, with images recordedin10 minutes interval since October 2013.Images near local noon homogeneous diffuse lighting were selectedfor leaf phenologymonitoring; (2) ground based bi-weekly biometry survey (via dendrometry band technique) for 25 trees from random sampling since September 2013. 12 among 25 trees are within the tower mounted camera image view. Our preliminary resultsdemonstrate that 20 trees among 25 trees surveyed significantly increase woody growth (or "green up") in dry season. Our results also find thatamong those 20 trees, 12 trees reaches the maximum woody increment rate in late dry season with a mean DBH (Diameter at Breast Height) around 30 cm,while 8 trees reaching the maximum in the middle of wet season, with a mean DBH around 90 cm. This study,though limited in the sample size, mightprovide another line of evidence that Amazon rainforests "green up" in dry season. As for mechanistic controls on tropical tree woody control, we hypothesize both climate and leaf phenology control individual woody growth. We would like to link both camera based leaf phenology and climate data in the next to explorethe reason as to the pattern found in this study that bigger trees might have different seasonal growth pattern as smaller trees.

  14. Determination of Morphological, Biometric and Biochemical Susceptibilities in Healthy Eurasier Dogs with Suspected Inherited Glaucoma

    PubMed Central

    Goulle, Frédéric; Thomas, Philippe; Isard, Pierre-François; Azoulay, Thierry; Lafarge-Beurlet, Stéphanie; Woods, Mike; Lavillegrand, Sylvie; Ivkovic, Ivana; Neveux, Nathalie; Sahel, José-Alain; Picaud, Serge; Froger, Nicolas

    2014-01-01

    In both humans and dogs, the primary risk factor for glaucoma is high intraocular pressure (IOP), which may be caused by iridocorneal angle (ICA) abnormalities. Oxidative stress has also been implicated in retinal ganglion cell damage associated with glaucoma. A suspected inherited form of glaucoma was recently identified in Eurasier dogs (EDs), a breed for which pedigrees are readily available. Because of difficulties in assessing ICA morphology in dogs with advanced glaucoma, we selected a cohort of apparently healthy dogsfor the investigation of ICA morphological status, IOP and plasma concentrations of oxidative stress biomarkers. We aimed to establish correlations between these factors, to identify predictive markers of glaucoma in this dog breed. A cohort of 28 subjects, volunteered for inclusion by their owners, was selected by veterinary surgeons. These dogs were assigned to four groups: young males, young females (1–3 years old), adult males and adult females (4–8 years old). Ocular examination included ophthalmoscopy, tonometry, gonioscopy, biometry and ultrasound biomicroscopy (UBM), and the evaluation of oxidative stress biomarkers consisting of measurements of plasma glutathione peroxidase (GP) activity and taurine and metabolic precursor (methionine and cysteine) concentrations in plasma. The prevalence of pectinate ligament abnormalities was significantly higher in adult EDs than in young dogs. Moreover, in adult females, high IOP was significantly correlated with a short axial globe length, and a particularly large distance between Schwalbe's line and the anterior lens capsule. GP activity levels were significantly lower in EDs than in a randomized control group of dogs, and plasma taurine concentrations were higher. Hence, ICA abnormalities were associated with weaker antioxidant defenses in EDs, potentially counteracted by higher plasma taurine concentrations. This study suggests that EDs may constitute an appropriate canine model for the development of glaucoma. This cohort will be used as a sentinel for longitudinal monitoring. PMID:25380252

  15. Effectiveness of combined macular buckle under direct vision and vitrectomy with ILM peeling in refractory macular hole retinal detachment with extreme high axial myopia: a 24-month comparative study

    PubMed Central

    Ma, Jin; Li, Honghui; Ding, Xiaohu; Tanumiharjo, Silvia; Lu, Lin

    2017-01-01

    Purpose To evaluate the efficacy of a combined macular buckle under direct vision and 23-gauge pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling in refractory macular hole retinal detachment (MHRD) with extreme high axial myopia. Design Prospective, randomised controlled study. Participants The study included 98 eyes of 98 patients of MHRD with extreme high axial (>30 mm) myopia. Intervention Patients were randomly assigned to undergo PPV with ILM peeling (group 1, n=52) or PPV with ILM peeling combined with macular buckle under direct vision (group 2, n=46). Main outcome measures Complete ocular examination included best-corrected visual acuity (BCVA) (LogMAR), applanation tonometry, optical biometry, slit-lamp biomicroscopy, colour fundus photography, ultrasound examination and optical coherence tomography at baseline and every follow-up visit. Results Initial retinal reattachment rate was significantly higher in group 2 than in group 1 at 12-month postoperatively (χ2 test, p=0.020). Macular hole closure rate in group 2 was significantly higher than that in group 1 at 3, 12, 18 and 24 months postoperatively (Fisher's exact test, p<0.05). In initial retinal reattachment cases, the mean BCVA decreased significantly in group 2 than in group 1 at 3 months postoperatively (Wilcoxon matched pairs signed rank test, p=0.036), and had increased significantly in group 2 than in group 1 since 6 months postoperatively (Wilcoxon matched pairs signed rank test, p<0.05). Mean axial lengths in group 2 were significantly shorter than that of group 1 at each follow-up time point (Wilcoxon matched pairs signed rank test, p<0.05). Conclusions Combined macular buckle under direct vision and PPV with ILM peeling is more effective in treatment of MHRD with extreme high axial (>30 mm) myopia. PMID:28292775

  16. Finding the most accurate method to measure head circumference for fetal weight estimation.

    PubMed

    Schmidt, Ulrike; Temerinac, Dunja; Bildstein, Katharina; Tuschy, Benjamin; Mayer, Jade; Sütterlin, Marc; Siemer, Jörn; Kehl, Sven

    2014-07-01

    Accurate measurement of fetal head biometry is important for fetal weight estimation (FWE) and is therefore an important prognostic parameter for neonatal morbidity and mortality and a valuable tool for determining the further obstetric management. Measurement of the head circumference (HC) in particular is employed in many commonly used weight equations. The aim of the present study was to find the most accurate method to measure head circumference for fetal weight estimation. This prospective study included 481 term pregnancies. Inclusion criteria were a singleton pregnancy and ultrasound examination with complete fetal biometric parameters within 3 days of delivery, and an absence of structural or chromosomal malformations. Different methods were used for ultrasound measurement of the HC (ellipse-traced, ellipse-calculated, and circle-calculated). As a reference method, HC was also determined using a measuring tape immediately after birth. FWE was carried out with Hadlock formulas, including either HC or biparietal diameter (BPD), and differences were compared using percentage error (PE), absolute percentage error (APE), limits of agreement (LOA), and cumulative distribution. The ellipse-traced method showed the best results for FWE among all of the ultrasound methods assessed. It had the lowest median APE and the narrowest LOA. With regard to the cumulative distribution, it included the largest number of cases at a discrepancy level of ±10%. The accuracy of BPD was similar to that of the ellipse-traced method when it was used instead of HC for weight estimation. Differences between the three techniques for calculating HC were small but significant. For clinical use, the ellipse-traced method should be recommended. However, when BPD is used instead of HC for FWE, the accuracy is similar to that of the ellipse-traced method. The BPD might therefore be a good alternative to head measurements in estimating fetal weight. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Anterior segment optical coherence tomography parameters in phacomorphic angle closure and mature cataracts.

    PubMed

    Mansouri, Mohammadreza; Ramezani, Farshid; Moghimi, Sasan; Tabatabaie, Ali; Abdi, Fatemeh; He, Mingguang; Lin, Shan C

    2014-10-21

    To describe anterior segment optical coherence tomography (AS-OCT) parameters in phacomorphic angle closure eyes, mature cataract eyes, and their fellow eyes, and identify those parameters that could be used to differentiate phacomorphic angle closure eyes from those with mature cataract and no phacomorphic angle closure. In this cross-sectional study, a total of 33 phacomorphic angle closure subjects and 34 control patients with unilateral mature cataracts were enrolled. All patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth (ACD), anterior chamber area (ACA), iris thickness, iris curvature, lens vault (LV), and angle parameters, including angle opening distance (AOD750) and trabecular-iris space area (TISA750), were measured in qualified images using customized software and compared among eyes with phacomorphic angle closure, mature cataract eyes, and their fellow eyes. There was no significant difference in axial length among the four groups. Phacomorphic angle closure had the smallest angle (AOD750, TISA750) and anterior chamber parameters (ACD, ACA, anterior chamber width) and the greatest LV among the groups. This pattern was similar when comparing fellow eyes of mature cataract patients and fellow eyes of phacomorphic angle closure. Anterior chamber area less than 18.62 mm(2), ACD less than 2.60 mm, LV greater than 532.0 μm, and AOD750 less than 0.218 mm had the highest odds ratios (ORs) for distinguishing fellow eyes of phacomorphic angle closure versus fellow eyes of mature cataracts, with OR values of 9.90, 8.31, 7.91, and 7.91, respectively. Logistic regression showed that ACA less than 18.62 was the major parameter associated with fellow eyes of phacomorphic angle closure (OR = 10.96, P < 0.001). Anterior chamber depth, ACA, AOD750, and LV are powerful indicators in differentiating phacomorphic angle closure eyes from those with mature cataract and their fellow eyes. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  18. Biometry Characteristics in Adults and Children With Marfan Syndrome: From the Marfan Eye Consortium of Chicago.

    PubMed

    Kinori, Michael; Wehrli, Sarah; Kassem, Iris S; Azar, Nathalie F; Maumenee, Irene H; Mets, Marilyn B

    2017-05-01

    To report on the biometric findings of adults and children with Marfan syndrome (MFS) recruited from 2 annual National Marfan Foundation conferences (2012 and 2015). Cross-sectional study. Subjects diagnosed with MFS by Ghent 2 nosology were included for analysis. Subjects were divided into "adults" (≥16 years of age) and "children" (5-15 years of age). Biometric data included values for refractive error, axial length (AL), corneal curvature, anterior chamber depth, lens thickness, and central corneal thickness. Of the 117 subjects evaluated, 74 (35 adults, 32 children, and 7 children <5 years of age) had a definite diagnosis of MFS and were included in the study. The AL was longer (25.25 ± 0.32 mm vs 24.24 ± 0.33 mm, P = .03) and the lens was thicker (3.94 ± 0.09 mm vs 3.62 ± 0.10 mm, P = .03) in adults. Both groups had flat corneas (average keratometry [K med ] of 41.59 ± 0.35 diopters [D] in adults vs 40.89 ± 0.36 D in children, P = .17). A negative correlation was found between AL and K med (-0.33, P < .001). The corneas of patients with MFS with ectopia lentis (EL) were significantly flatter and with higher degree of corneal astigmatism compared to patients without EL (K med of 40.68 ± 0.31 D vs 41.75 ± 0.28 D, P < .01 and corneal astigmatism of 1.68 ± 0.16 D vs 1.13 ± 0.14 D, P = .01). Children with established MFS have flat corneas at least to the same degree as adults. Corneas of patients with MFS with EL are flatter and have a higher degree of corneal astigmatism. We strongly suggest that corneal parameters should be measured if MFS is suspected, especially in children that may not yet have developed EL. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Patterns of NPP, GPP, respiration, and NEP during boreal forest succession

    USGS Publications Warehouse

    Goulden, M.L.; Mcmillan, A.M.S.; Winston, G.C.; Rocha, A.V.; Manies, K.L.; Harden, J.W.; Bond-Lamberty, B. P.

    2011-01-01

    We combined year-round eddy covariance with biometry and biomass harvests along a chronosequence of boreal forest stands that were 1, 6, 15, 23, 40, 74, and 154 years old to understand how ecosystem production and carbon stocks change during recovery from stand-replacing crown fire. Live biomass (Clive) was low in the 1 and 6 year old stands, and increased following a logistic pattern to high levels in the 74 and 154year old stands. Carbon stocks in the forest floor (Cforest floor) and coarse woody debris (CCWD) were comparatively high in the 1year old stand, reduced in the 6 through 40year old stands, and highest in the 74 and 154year old stands. Total net primary production (TNPP) was reduced in the 1 and 6year old stands, highest in the 23 through 74year old stands and somewhat reduced in the 154year old stand. The NPP decline at the 154year old stand was related to increased autotrophic respiration rather than decreased gross primary production (GPP). Net ecosystem production (NEP), calculated by integrated eddy covariance, indicated the 1 and 6 year old stands were losing carbon, the 15year old stand was gaining a small amount of carbon, the 23 and 74year old stands were gaining considerable carbon, and the 40 and 154year old stands were gaining modest amounts of carbon. The recovery from fire was rapid; a linear fit through the NEP observations at the 6 and 15year old stands indicated the transition from carbon source to sink occurred within 11-12 years. The NEP decline at the 154year old stand appears related to increased losses from Clive by tree mortality and possibly from Cforest floor by decomposition. Our findings support the idea that NPP, carbon production efficiency (NPP/GPP), NEP, and carbon storage efficiency (NEP/TNPP) all decrease in old boreal stands. ?? 2010 Blackwell Publishing Ltd.

  20. Reference centiles for the middle cerebral artery and umbilical artery pulsatility index and cerebro-placental ratio from a low-risk population - a Generalised Additive Model for Location, Shape and Scale (GAMLSS) approach.

    PubMed

    Flatley, Christopher; Kumar, Sailesh; Greer, Ristan M

    2018-02-06

    The primary aim of this study was to create reference ranges for the fetal Middle Cerebral artery Pulsatility Index (MCA PI), Umbilical Artery Pulsatility Index (UA PI) and the Cerebro-Placental Ratio (CPR) in a clearly defined low-risk cohort using the Generalised Additive Model for Location, Shape and Scale (GAMLSS) method. Prospectively collected cross-sectional biometry and Doppler data from low-risk women attending the Mater Mother's Hospital, Maternal and Fetal Medicine Department in Brisbane, Australia between January 2010 and April 2017 were used to derive gestation specific centiles for the MCA PI, UA PI and CPR. All ultrasound scans were performed between 18 + 0 and 41 + 6 weeks gestation with recorded data for the MCA PI and/or UA PI. The GAMLSS method was used for the calculation of gestational age-adjusted centiles. Distributions and additive terms were assessed and the final model was chosen on the basis of the Global Deviance, Akaike information criterion (AIC) and Schwartz bayesian criterion (SBC), along with the results of the model and residual diagnostics as well as visual assessment of the centiles themselves. Over the study period 6013 women met the inclusion criteria. The MCA PI was recorded in 4473 fetuses, the UA PI in 6008 fetuses and the CPR was able to be calculated in 4464 cases. The centiles for the MCA PI used a fractional polynomial additive term and Box-Cox t (BCT) distribution. Centiles for the UA PI used a cubic spline additive term with BCT distribution and the CPR used a fractional polynomial additive term and a BCT distribution. We have created gestational centile reference ranges for the MCA PI, UA PI and CPR from a large low-risk cohort that supports their applicability and generalisability.

  1. Growth patterns and cerebro-placental hemodynamics in fetuses with congenital heart disease.

    PubMed

    Mebius, M J; Clur, S A B; Vink, A S; Pajkrt, E; Kalteren, W S; Kooi, E M W; Bos, A F; du Marchie Sarvaas, G J; Bilardo, C M

    2018-05-28

    Congenital heart disease (CHD) has been associated with a reduced fetal head circumference (HC). The underlying pathophysiological background remains undetermined. We aimed to define trends in fetal growth and cerebro-placental Doppler flow, and to investigate the association between head growth and cerebro-placental flow in fetuses with CHD. Fetuses with CHD and serial measurements of HC, abdominal circumference (AC), middle cerebral artery pulsatility index (MCA-PI), umbilical artery pulsatility index (UA-PI), and cerebro-placental ratio (CPR) were included. CHD was categorized into 3 groups based on expected cerebral arterial oxygen saturation: normal, mild to moderately reduced, and severely reduced. Trends over time in Z-scores were analyzed using a linear mixed-effects model. 181 fetuses fulfilled the inclusion criteria. Expected cerebral arterial oxygen saturation in CHD was classified as normal in 44, mild to moderately reduced in 84 and severely reduced in 53 cases. HC z-scores showed a tendency to decrease until 23 weeks, then to increase until 33 weeks, followed by a decrease again in the late third trimester. AC increased progressively with advancing gestation. MCA-PI and UA-PI showed significant trends throughout pregnancy, but CPR did not. There were no associations between expected cerebral arterial oxygen saturation and fetal growth. Average trends in MCA-PI were significantly different in the three subgroups (P=0.010), whereas average trends in UA-PI and CPR were similar (P=0.530 and P=0.285). Furthermore, there was no significant association between MCA-PI and HC (P=0.284). Fetal biometry and Doppler flow patterns are within normal ranges in fetuses with CHD, but show trends over time. Fetal head growth is not associated with the cerebral blood flow pattern or placental function and HC is not influenced by the cerebral arterial oxygen saturation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  2. Eopolydiexodina (Middle Permian giant fusulinids) from Afghanistan: Biometry, morphometry, paleobiogeography, and end-Guadalupian events

    NASA Astrophysics Data System (ADS)

    Colpaert, Clémentine; Monnet, Claude; Vachard, Daniel

    2015-04-01

    The most spectacular macroevolutionary trend presented by the genera of schwagerinoid fusulinids, during the Pennsylvanian -Permian, is an enormous increase in size, which culminated in the Middle Permian with Eopolydiexodina. However, this potential major biogeographic marker, during the Kubergandian-early Midian time interval, is as yet hampered by its poor taxonomic characterization. Hence, Eopolydiexodina is revised here using biometric and morphometric methods applied to large collections from Afghanistan and selected taxa in the literature. These multivariate analyses consist of classical linear test parameters, as well as new area parameters acquired by computer image analysis. The Afghan species are re-defined, and some other species, occasionally described as Cimmerian, are re-discussed. These methods, combined with classical morphological analyses, also permit to conclude that the largest Eopolydiexodina of Afghanistan are microspheric specimens (probably agamonts) of E. afghanensis and E. bithynica. Two megalospheric groups of individuals (probably gamonts and schizonts) are represented in both species, as well as in E. persica and E. darvasica. Due to this presence of gamonts, agamonts and schizonts in several species, Eopolydiexodina is probably the oldest identified trimorphic genus among the large benthic foraminifers. Biostratigraphically, Eopolydiexodina appears restricted to the late Kubergandian to early Midian. The associated Afghan fusulinids (Dunbarula, Kahlerina, Afghanella, Yangchienia, Sumatrina, and Codonofusiella) allow proposing an accurate biostratigraphy of the Eopolydiexodina species in the Murgabian-Midian boundary interval. Paleobiogeographically, Eopolydiexodina was essentially located in the Laurentian and Perigondwanan borders of the Tethys. The possible presence of Eopolydiexodina in the Cimmerian Continent and in some regions of China has never been irrefutably demonstrated. This paleobiological revision of Eopolydiexodina and the biostratigraphic revision of other large Capitanian fusulinids, permit to suggest that the end-Guadalupian event is most probably a protracted succession of last appearance data of giant genera rather than an instantaneous Lilliput effect at the Capitanian/Wuchiapingian boundary.

  3. Optic Nerve Tilt, Crescent, Ovality, and Torsion in a Multi-Ethnic Cohort of Young Adults With and Without Myopia

    PubMed Central

    Marsh-Tootle, Wendy L.; Harb, Elise; Hou, Wei; Zhang, Qinghua; Anderson, Heather A.; Weise, Katherine; Norton, Thomas T.; Gwiazda, Jane; Hyman, Leslie

    2017-01-01

    Purpose The purpose of this article is to evaluate optic nerve head (ONH) characteristics in an ethnically diverse cohort of young U.S. adults. Methods In this study, 409 myopes and 206 nonmyopes (median age 22 years) completed measures including biometry and spectral domain optical coherence tomography from enface (ovality and torsion) and cross-sectional (tilt and crescent width) scans. Associated factors were evaluated using multivariable models. Results In myopic versus nonmyopic right eyes, median tilt (6.0° vs. 2.4°; P < 0.0001) and frequency of crescents (49% vs. 10%; P < 0.0001) were higher in myopes. Right eyes with crescents had higher median tilts (8.8° [myopic], 9.0° [nonmyopic]) than those without crescent (2.5° [myopic], 2.1° [nonmyopic]), irrespective of refractive group (both P < 0.0001). Torsion was similar between groups, with a slight difference in ovality (0.89 vs. 0.91; P < 0.03). Data in the left eyes were similar, and modeling was done only for the right myopic eyes. Multivariable models showed that an increased tilt was associated with ethnicity (P < 0.001), the presence of crescent (P < 0.001), and smaller ONH diameter (P < 0.0031), with interactions between ethnicity and crescent (P = 0.002). Specifically, ONH tilt was significantly higher in Asian eyes without crescent (P < 0.0001 for all comparisons), and crescent width was associated with increased tilt in non-Asian eyes (P < 0.02). Crescent width was associated with ethnicity (greatest in Asians) and disc tilt. Interactions were observed between tilt and ethnicity, whereby tilt had a greater effect on crescent width in non-Asian eyes, and crescent width was associated with increased tilt in non-Asian eyes. Conclusions The data clarify the influence of ethnicity and myopia on ONH characteristics in young adults and may inform future studies of biomechanical properties or of retinal pathology of the myopic eye. PMID:28654981

  4. Biometry Characteristics in Adults and Children With Marfan Syndrome: From the Marfan Eye Consortium of Chicago

    PubMed Central

    KINORI, MICHAEL; WEHRLI, SARAH; KASSEM, IRIS S.; AZAR, NATHALIE F.; MAUMENEE, IRENE H.; METS, MARILYN B.

    2017-01-01

    PURPOSE To report on the biometric findings of adults and children with Marfan syndrome (MFS) recruited from 2 annual National Marfan Foundation conferences (2012 and 2015). DESIGN Cross-sectional study. METHODS Subjects diagnosed with MFS by Ghent 2 nosology were included for analysis. Subjects were divided into “adults” (≥16 years of age) and “children” (5–15 years of age). Biometric data included values for refractive error, axial length (AL), corneal curvature, anterior chamber depth, lens thickness, and central corneal thickness. RESULTS Of the 117 subjects evaluated, 74 (35 adults, 32 children, and 7 children <5 years of age) had a definite diagnosis of MFS and were included in the study. The AL was longer (25.25 ± 0.32 mm vs 24.24 ± 0.33 mm, P [ .03) and the lens was thicker (3.94 ± 0.09 mm vs 3.62 ± 0.10 mm, P [ .03) in adults. Both groups had flat corneas (average keratometry [Kmed] of 41.59 ± 0.35 diopters [D] in adults vs 40.89 ± 0.36 D in children, P [ .17). A negative correlation was found between AL and Kmed (L0.33, P < .001). The corneas of patients with MFS with ectopia lentis (EL) were significantly flatter and with higher degree of corneal astigmatism compared to patients without EL (Kmed of 40.68 ± 0.31 D vs 41.75 ± 0.28 D, P < .01 and corneal astigmatism of 1.68 ± 0.16 D vs 1.13 ± 0.14 D, P =.01). CONCLUSIONS Children with established MFS have flat corneas at least to the same degree as adults. Corneas of patients with MFS with EL are flatter and have a higher degree of corneal astigmatism. We strongly suggest that corneal parameters should be measured if MFS is suspected, especially in children that may not yet have developed EL. PMID:28257833

  5. EULAR recommendations for women's health and the management of family planning, assisted reproduction, pregnancy and menopause in patients with systemic lupus erythematosus and/or antiphospholipid syndrome.

    PubMed

    Andreoli, L; Bertsias, G K; Agmon-Levin, N; Brown, S; Cervera, R; Costedoat-Chalumeau, N; Doria, A; Fischer-Betz, R; Forger, F; Moraes-Fontes, M F; Khamashta, M; King, J; Lojacono, A; Marchiori, F; Meroni, P L; Mosca, M; Motta, M; Ostensen, M; Pamfil, C; Raio, L; Schneider, M; Svenungsson, E; Tektonidou, M; Yavuz, S; Boumpas, D; Tincani, A

    2017-03-01

    Develop recommendations for women's health issues and family planning in systemic lupus erythematosus (SLE) and/or antiphospholipid syndrome (APS). Systematic review of evidence followed by modified Delphi method to compile questions, elicit expert opinions and reach consensus. Family planning should be discussed as early as possible after diagnosis. Most women can have successful pregnancies and measures can be taken to reduce the risks of adverse maternal or fetal outcomes. Risk stratification includes disease activity, autoantibody profile, previous vascular and pregnancy morbidity, hypertension and the use of drugs (emphasis on benefits from hydroxychloroquine and antiplatelets/anticoagulants). Hormonal contraception and menopause replacement therapy can be used in patients with stable/inactive disease and low risk of thrombosis. Fertility preservation with gonadotropin-releasing hormone analogues should be considered prior to the use of alkylating agents. Assisted reproduction techniques can be safely used in patients with stable/inactive disease; patients with positive antiphospholipid antibodies/APS should receive anticoagulation and/or low-dose aspirin. Assessment of disease activity, renal function and serological markers is important for diagnosing disease flares and monitoring for obstetrical adverse outcomes. Fetal monitoring includes Doppler ultrasonography and fetal biometry, particularly in the third trimester, to screen for placental insufficiency and small for gestational age fetuses. Screening for gynaecological malignancies is similar to the general population, with increased vigilance for cervical premalignant lesions if exposed to immunosuppressive drugs. Human papillomavirus immunisation can be used in women with stable/inactive disease. Recommendations for women's health issues in SLE and/or APS were developed using an evidence-based approach followed by expert consensus. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Lens power in Iranian schoolchildren: a population-based study.

    PubMed

    Hashemi, Hassan; Pakzad, Reza; Iribarren, Rafael; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Fotouhi, Akbar

    2018-06-01

    To evaluate lens power (LP) in schoolchildren aged 6-12 years. This cross-sectional study was conducted in Shahroud, northeast Iran. The students were selected through random cluster sampling and underwent the measurements of biometry, uncorrected and corrected visual acuity, non-cycloplegic and cycloplegic refraction. The LP was calculated using the Bennett formula. Of 6624 invited children, 5620 (84.8%) participated in the study and data of 4870 children were finally analysed. The mean age of the participants was 9.7 years and 2277 participants (46.02%) were girls. The mean LPs were 22.86 dioptres (D) in total study population, 23.91 D in 6 and 22.10 D in 12-year-old children. The mean LP was higher in girls than boys (23.48 D vs 22.34 D), in rural children than urban children (23.17 D vs 22.83 D) and in children with hyperopia (23.25 D) than children with myopia or emmetropia (22.64 D and 22.86 D, respectively). In the multiple linear regression model, lens thickness (β=1.59, p<0.001), anterior chamber depth (β=2.21, p<0.001) and female sex (β=0.016, p=0.015) were associated with an increase in the LP, while axial length (AL) (β=-4.41, p<0.001), corneal power (CP) (β=-1.47, p<0.001), spherical equivalent (SE) (β=-1.50, p<0.001) and age (β=-0.005, p=0.001) were associated with a decrease in the LP. AL and sex had the highest and lowest impact on LP, respectively. LP decreased with age between 6 and 12 years and was associated with a shorter AL, deeper ACD, higher SE, thicker lens and lower CP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy

    PubMed Central

    Balakrishna, Nagalla

    2017-01-01

    Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student’s t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 pm from scleral spur (AOD 500), trabecular-ciliary process distance (TCPD), iris-ciliary process distance (ICPD), and iris-zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral-iris angle (SIA), and scleral-ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris-lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article: Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy. J Curr Glaucoma Pract 2017;11(3):86-91. PMID:29151682

  8. Influence of Land Cover Heterogeneity, Land-Use Change and Management on the Regional Carbon Cycle in the Upper Midwest USA as Evaluated by High-Density Observations and a Dynamic Ecosystem Model

    NASA Astrophysics Data System (ADS)

    Desai, A. R.; Bolstad, P. V.; Moorcroft, P. R.; Davis, K. J.

    2005-12-01

    The interplay between land use change, forest management and land cover variability complicates the ability to characterize regional scale (10-1000 km) exchange of carbon dioxide between the land surface and atmosphere in heterogeneous landscapes. An attempt was made to observe and model these factors and their influence on the regional carbon cycle across the upper Midwest USA. A high density of eddy-covariance carbon flux, micrometeorology, carbon dioxide mixing ratio, stand-scale biometry and canopy component flux observations have been occurring in this area as part of the Chequamegon Ecosystem-Atmosphere Study. Observations limited to sampling only dominant stands and coarse-resolution biogeochemical models limited to biome-scale parameterization neither accurately capture the variability of carbon fluxes measured by the network of eddy covariance towers nor match the regional-scale carbon flux inferred from very tall tower eddy covariance measurements and multi-site upscaling. Analysis of plot level biometric data, U.S. Forest Service Forest Inventory Analysis data and high-resolution land cover data around the tall tower revealed significant variations in vegetation type, stand age, canopy stocking and structure. Wetlands, clearcuts and recent natural disturbances occur in characteristic small non-uniformly distributed patches that aggregate to form more than 30% of the landscape. The Ecosystem Demography model, a dynamic ecosystem model that incorporates vegetation heterogeneity, canopy structure, stand age, disturbance, land use change and forest management, was parameterized with regional biometric data and meteorology, historical records of land management and high-resolution satellite land cover maps. The model will be used to examine the significance of past land use change, natural disturbance history and current forest management in explaining landscape structure and regional carbon fluxes observed in the region today.

  9. New mononuclear leukocyte-like populations within the granulocyte scatter gate detected by flow cytometry (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Melzer, Susanne; Löffler, Markus; Kautzner, Marlene; Tárnok, Attila

    2017-02-01

    Granulocytes are the major players in innate immunity and are prognostic markers in diseases. An in-depth phenotypic characterization of granulocyte subtypes and correlation with biometry or lifestyle is so far lacking. The reason is, that either preparation of mononuclear cells was analyzed or that cells in the neutrophil window were neglected in the analysis. Here we show for the first time lymphocyte- (LL) and monocyte-like (ML) cells within the granulocyte scatter gate as new, previously unknown cell subpopulation. Immunophenotyping of 905 healthy German adults from the LIFE study [1] was performed by 10-color flow cytometry [2]. Age of men (n=420): 56.5±14.0 years, women (n=485): 56.7±13.6 y (range of 18-81 y). Data analyzed by FlowJo v10.0.6. Values compared by Mann-Whitney-U test: men vs women, young (18-49 y) vs. elderly (50-81 y.) men, and young (19-49 y.) vs. elderly (50-81 y.) women; significance: p<0.05. Within the granulocyte gate four phenotypically distinct cell types were detected (all CD45+, SSCmid-high): LL1 CD3+,CD4+,CD8++,CD16/56+,CD38+,HLA-DR+ LL2 CD3+,CD4low,CD8+,CD38low LL3 CD3+,CD4+,CD8- ML1 CD3-,CD4low,CD14+,CD38+ LL2 counts were increased in men (p=0.042), as well as ML1 counts (p <0.001). Most of the cell counts were not dependent on age, except LL2 in women. In conclusion, new lymphocyte like cell types with the neutrophil scatter characteristics are reported. Counts correlate with age and gender. We plan to sort these new subtypes for further functional characterization and aim to establish them as cellular biomarkers for the early detection of various diseases. [1] BMC Public Health. 2015;15:691; [2] Cytometry A. 2014;85(9):781

  10. Anterior segment biometry using ultrasound biomicroscopy and the Artemis-2 very high frequency ultrasound scanner

    PubMed Central

    Al-Farhan, Haya M; AlMutairi, Reem N

    2013-01-01

    Purpose To compare the precision of anterior chamber angle (ACA) and anterior chamber depth (ACD) measurements taken with ultrasound biomicroscopy (UBM) and the Artemis-2 Very High Frequency Ultrasound Scanner (VHFUS) in normal subjects. Design Prospective study. Methods We randomly selected one eye from each of 59 normal subjects in this study. Two subjects dropped out of the study; the associated data were excluded from analysis. ACA and ACD measurements were obtained using the VHFUS and the UBM. The results were compared statistically using repeated-measures analysis of variance for the intraobserver repeatability, unpaired t-test, and limits of agreement. Results The average ACA values for the UBM and the VHFUS (±standard deviation) were 41.83° ± 5.03° and 33.36° ± 6.03°, respectively. The average ACD values were 2.96 ± 0.34 mm and 2.87 ± 0.31 mm. The intraobserver repeatability analysis of variance P-values for ACA and ACD measurements using UBM were 0.10 and 0.68, respectively; for the Artemis-2 VHFUS, the respective values were 0.68 and 0.09. The difference in ACA measurements was statistically significant (t = 8.41; P < 0.0001), while the difference in ACD values was not (t = 1.51; P < 0.13). The mean ACA difference was 8.50° ± 2.50°, and the limits of agreement were +13.30° to −3.60°. The mean ACD difference was 0.09 ± 0.27 mm, and the limits of agreement ranged from 0.61 mm to −0.43 mm. The mean difference percentage of ACD was 3.1% for both instruments. Conclusion In case of the ACD, both instruments can be used interchangeably; however, with the ACA instruments, they cannot be used interchangeably. PMID:23345968

  11. Revealed versus concealed criteria for placental insufficiency in an unselected obstetric population in late pregnancy (RATIO37): randomised controlled trial study protocol

    PubMed Central

    Figueras, Francesc; Gratacos, Eduard; Rial, Marta; Gull, Ilan; Krofta, Ladislav; Lubusky, Marek; Rogelio, Cruz-Martinez; Mónica, Cruz-Lemini; Miguel, Martinez-Rodriguez; Socias, Pamela; Aleuanlli, Cristina; Cordero, Mauro C Parra

    2017-01-01

    Introduction Fetal growth restriction (FGR) affects 5%–10% of all pregnancies, contributing to 30%–50% of stillbirths. Unfortunately, growth restriction often is not detected antenatally. The last weeks of pregnancy are critical for preventing stillbirth among babies with FGR because there is a pronounced increase in stillbirths among growth-restricted fetuses after 37 weeks of pregnancy. Here we present a protocol (V.1, 23 May 2016) for the RATIO37 trial, which evaluates an integrated strategy for accurately selecting at-risk fetuses for delivery at term. The protocol is based on the combination of fetal biometry and cerebroplacental ratio (CPR). The primary objective is to reduce stillbirth rates. The secondary aims are to detect low birth weights and adverse perinatal outcomes. Methods and analysis The study is designed as multicentre (Spain, Chile, Mexico,Czech Republic and Israel), open-label, randomised trial with parallel groups. Singleton pregnancies will be invited to participate after routine second-trimester ultrasound scan (19+0–22+6 weeks of gestation), and participants will be randomly allocated to receive revealed or concealed CPR evaluation. Then, a routine ultrasound and Doppler scan will be performed at 36+0–37+6 weeks. Sociodemographic and clinical data will be collected at enrolment. Ultrasound and Doppler variables will be recorded at 36+0–37+6 weeks of pregnancy. Perinatal outcomes will be recorded after delivery. Univariate (with estimated effect size and its 95% CI) and multivariate (mixed-effects logistic regression) comparisons between groups will be performed. Ethics and dissemination The study will be conducted in accordance with the principles of Good Clinical Practice. This study was accepted by the Clinical Research Ethics Committee of Hospital Clinic Barcelona on 23May 2016. Subsequent approval by individual ethical committees and competent authorities was granted. The study results will be published in peer-reviewed journals and disseminated at international conferences. Trial registration number NCT02907242; pre-results. PMID:28619771

  12. Influence of the effective lens position, as predicted by axial length and keratometry, on the near add power of multifocal intraocular lenses.

    PubMed

    Savini, Giacomo; Hoffer, Kenneth J; Lombardo, Marco; Serrao, Sebastiano; Schiano-Lomoriello, Domenico; Ducoli, Pietro

    2016-01-01

    To calculate the near focal distance of different multifocal intraocular lenses (IOLs) as a function of the 2 parameters that are measured before cataract surgery; that is, axial length (AL) and refractive corneal power (keratometry [K]). GB Bietti Foundation IRCCS, Rome, Italy. Noninterventional theoretical study. The IOL power for emmetropia was first calculated in an eye model with the AL ranging from 20 to 30 mm and K from 38 to 48 diopters (D). Then, the predicted myopic refraction for any given IOL add power (from +1.5 to +4.0 D) was calculated, and from this value the near focal distance was obtained. Calculations were also performed for the average eye (K = 43.81 D; AL = 23.65 mm). The near focal distance increased with increasing values of K and AL for each near power add. The near focal distance ranged between 53 cm and 72 cm (21 inches and 28 inches) for a multifocal IOL with +2.50 D, between 44 cm and 60 cm (17 inches and 24 inches) for a multifocal IOL with +3.00 D add, and between 33 cm and 44 cm (13 inches and 18 inches) for a multifocal IOL with +4.00 D add. In the average eye, the near focal distance ranges between 36 cm (near add power = 4.00 D) and 99 cm (near add power = 1.5 D). Longer eyes with steeper corneas showed the longest near focal distance and could experience more difficulties in focusing near objects after surgery. The opposite was true for short hyperopic eyes. Dr. Hoffer receives licensing fees for the commercial use of the registered trademark Hoffer from all biometry manufacturers using the Hoffer Q formula to ensure that it is programmed correctly and book royalties from Slack, Inc., for the textbook IOL Power. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Gestational age assessment in malaria pregnancy cohorts: a prospective ultrasound demonstration project in Malawi.

    PubMed

    Wylie, Blair J; Kalilani-Phiri, Linda; Madanitsa, Mwayi; Membe, Gladys; Nyirenda, Osward; Mawindo, Patricia; Kuyenda, Redson; Malenga, Albert; Masonbrink, Abbey; Makanani, Bonus; Thesing, Phillip; Laufer, Miriam K

    2013-06-04

    Malaria during pregnancy is associated with an increased risk for low birth weight (<2500 grams). Distinguishing infants that are born premature (< 37 weeks) from those that are growth-restricted (less than the 10th percentile at birth) requires accurate assessment of gestational age. Where ultrasound is accessible, sonographic confirmation of gestational age is more accurate than menstrual dating. The goal was to pilot the feasibility and utility of adding ultrasound to an observational pregnancy malaria cohort. In July 2009, research staff (three mid-level clinical providers, one nurse) from The Blantyre Malaria Project underwent an intensive one-week ultrasound training to perform foetal biometry. Following an additional four months of practice and remote image review, subjects from an ongoing cohort were recruited for ultrasound to determine gestational age. Gestational age at delivery established by ultrasound was compared with postnatal gestational age assessment (Ballard examination). One hundred and seventy-eight women were enrolled. The majority of images were of good quality (94.3%, 509/540) although a learning curve was apparent with 17.5% (24/135) images of unacceptable quality in the first 25% of scans. Ultrasound was used to date 13% of the pregnancies when menstrual dates were unknown and changed the estimated gestational age for an additional 25%. There was poor agreement between the gestational age at delivery as established by the ultrasound protocol compared to that determined by the Ballard examination (bias 0.8 weeks, limits of agreement -3.5 weeks to 5.1 weeks). The distribution of gestational ages by Ballard suggested a clustering of gestational age around the mean with 87% of the values falling between 39 and 41 weeks. The distribution of gestational age by ultrasound confirmed menstrual dates was more typical. Using ultrasound confirmed dates as the gold standard, 78.5% of preterm infants were misclassified as term and 26.8% of small-for gestational age infants misclassified as appropriately grown by Ballard. Ultrasound should be strongly considered in prospective malaria studies with obstetric endpoints to confirm gestational age and avoid misclassification of infants as premature or growth-restricted. The use of ultrasound does require a significant investment of time to maintain quality image acquisition.

  14. The combination of urinary IL - 6 and renal biometry as useful diagnostic tools to differentiate acute pyelonephritis from lower urinary tract infection.

    PubMed

    Azab, Sherif; Zakaria, Mostafa; Raafat, Mona; Seief, Hadeel

    2016-01-01

    To evaluate the role of renal ultrasound (RUS) and urinary IL-6 in the differentiation between acute pyelonephritis (APN) and lower urinary tract infection (LUTI). This prospective study was carried out at the Pediatric and urology outpatient and inpatient departments of Cairo University Children's Hospital as well as October 6 University Hospital and it included 155 children between one month and fourteen years old with positive culture UTI. Patients were categorized into APN and LUTI based on their clinical features and laboratory parameters. Thirty healthy children, age and sex matched constituted the control group. Children with positive urine cultures were treated with appropriate antibiotics. Before treatment, urinary IL-6 was measured by enzyme immunoassay technique (ELISA), and renal ultrasound (RUS) was done. CRP (C-reactive protein), IL-6 and RUS were repeated on the 14th day of antibiotic treatment to evaluate the changes in their levels in response to treatment. UIL-6 levels were more significantly higher in patients with APN than in patients with LUTI (24.3±19.3pg/mL for APN vs. 7.3±2.7pg/mL in LUTI (95% CI: 2.6-27.4; p< 0.01). Similarly, serum CRP was more significantly higher in patients with APN than in children with LUTI (19.7±9.1μg/mL vs. 5.5±2.3μg/mL (p< 0.01). IL-6 levels >20pg/mL and serum CRP >20μg/mL were highly reliable markers of APN. Mean renal volume and mean volume difference between the two kidneys in the APN group were more than that of the LUTI and control groups (P< 0.001). Renal volume between 120-130% of normal was the best for differentiating APN from LUTI. RUS and urinary IL-6 levels have a highly dependable role in the differentiation between APN and LUTI especially in places where other investigations are not available and/ or affordable. Copyright© by the International Brazilian Journal of Urology.

  15. Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent refraction following intraocular lens implantation.

    PubMed

    McNeely, Richard N; Moutari, Salissou; Pazo, Eric; Moore, Jonathan E

    2018-01-01

    To investigate the impact of the orientation of preoperative corneal astigmatism on achieving the postoperative target refraction following monofocal intraocular lens (IOL) implantation. This study enrolled 339 eyes who had uneventful cataract surgery or refractive lens exchange (RLE) with subsequent monofocal IOL implantation. Eyes were initially categorized dependent upon axial length and then on the orientation of preoperative anterior corneal astigmatism. Group 1 had against-the-rule (ATR) anterior corneal astigmatism, group 2 had with-the-rule (WTR) anterior corneal astigmatism, and group 3 had oblique (OB) anterior corneal astigmatism. The preoperative corneal astigmatism was determined by the IOLMaster (Carl Zeiss Meditec AG). Postoperative refraction was completed for all eyes, and the results were calculated and compared for the separate groups. In eyes with axial lengths greater than 22.0 mm and less than 25.0 mm there was a significant difference between the magnitude of preoperative corneal astigmatism between groups 2 and 3 with 0.827 ± 0.376 D in group 2, and 0.677 ± 0.387 D in group 3. The mean postoperative spherical equivalent (SE) prediction error was - 0.132 ± 0.475 D in group 1, 0.026 ± 0.497 D in group 2, and - 0.130 ± 0.477 D in group 3. There was a significant difference between groups 1 and 2. There was no significant difference in the magnitude of preoperative corneal astigmatism and postoperative SE prediction error between the anterior corneal astigmatism orientation groups in eyes with axial lengths of less than or equal to 22.0 mm and greater than or equal to 25.0 mm. The orientation of preoperative anterior corneal astigmatism significantly affected the postoperative biometry prediction error in eyes with astigmatism of 1.75 D or less in eyes with the axial length between 22.0 mm and 25.0 mm. However, the results were not clinically significant.

  16. [Implantation of a sulcus-fixated toric additive intraocular lens in a case of high astigmatism after a triple procedure].

    PubMed

    Linz, K; Auffarth, G U; Kretz, F T A

    2014-08-01

    Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D. A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, - 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and - 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to - 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed. Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of the IOL. Georg Thieme Verlag KG Stuttgart · New York.

  17. Ametropia and ocular biometry in a U.K. university student population.

    PubMed

    Logan, Nicola S; Davies, Leon N; Mallen, Edward A H; Gilmartin, Bernard

    2005-04-01

    The prevalence of myopia is known to vary with age, ethnicity, level of education, and socioeconomic status, with a high prevalence reported in university students and in people from East Asian countries. This study determines the prevalence of ametropia in a mixed ethnicity U.K. university student population and compares associated ocular biometric measures. Refractive error and related ocular component data were collected on 373 first-year U.K. undergraduate students (mean age = 19.55 years +/- 2.99, range = 17-30 years) at the start of the academic year at Aston University, Birmingham, and the University of Bradford, West Yorkshire. The ethnic variation of the students was as follows: white 38.9%, British Asian 58.2%, Chinese 2.1%, and black 0.8%. Noncycloplegic refractive error was measured with an infrared open-field autorefractor, the Shin-Nippon NVision-K 5001 (Shin Nippon, Ryusyo Industrial Co. Ltd, Osaka, Japan). Myopia was defined as a mean spherical equivalent (MSE) less than or equal to -0.50 D. Hyperopia was defined as an MSE greater than or equal to +0.50 D. Axial length, corneal curvature, and anterior chamber depth were measured using the Zeiss IOLMaster (Carl Zeiss, Jena, GmBH). The analysis was carried out only for white and British Asian groups. The overall distribution of refractive error exhibited leptokurtosis, and prevalence levels were similar for white and British Asian (the predominant ethnic group) students across each ametropic group: myopia (50% vs. 53.4%), hyperopia (18.8% vs. 17.3%), and emmetropia (31.2% vs. 29.3%). There were no significant differences in the distribution of ametropia and biometric components between white and British Asian samples. The absence of a significant difference in refractive error and ocular components between white and British Asian students exposed to the same educational system is of interest. However, it is clear that a further study incorporating formal epidemiologic methods of analysis is required to address adequately the recent proposal that juvenile myopia develops principally from "myopiagenic" environments and is relatively independent of ethnicity.

  18. Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.

    PubMed

    de Castro, Alberto; Rosales, Patricia; Marcos, Susana

    2007-03-01

    To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus), custom algorithms, and a custom-built Purkinje imaging apparatus. Twenty-five Scheimpflug images of the anterior segment of the eye were obtained at different meridians. Custom algorithms were used to process the images (correction of geometrical distortion, edge detection, and curve fittings). Intraocular lens tilt and decentration were estimated by fitting sinusoidal functions to the projections of the pupillary axis and IOL axis in each image. The Purkinje imaging system captures pupil images showing reflections of light from the anterior corneal surface and anterior and posterior lens surfaces. Custom algorithms were used to detect the Purkinje image locations and estimate IOL tilt and decentration based on a linear system equation and computer eye models with individual biometry. Both methods were validated with a physical model eye in which IOL tilt and decentration can be set nominally. Twenty-one eyes of 12 patients with IOLs were measured with both systems. Measurements of the physical model eye showed an absolute discrepancy between nominal and measured values of 0.279 degree (Purkinje) and 0.243 degree (Scheimpflug) for tilt and 0.094 mm (Purkinje) and 0.228 mm (Scheimpflug) for decentration. In patients, the mean tilt was less than 2.6 degrees and the mean decentration less than 0.4 mm. Both techniques showed mirror symmetry between right eyes and left eyes for tilt around the vertical axis and for decentration in the horizontal axis. Both systems showed high reproducibility. Validation experiments on physical model eyes showed slightly higher accuracy with the Purkinje method than the Scheimpflug imaging method. Horizontal measurements of patients with both techniques were highly correlated. The IOLs tended to be tilted and decentered nasally in most patients.

  19. Compensation of Corneal Oblique Astigmatism by Internal Optics: a Theoretical Analysis

    PubMed Central

    Liu, Tao; Thibos, Larry N.

    2017-01-01

    Purpose Oblique astigmatism is a prominent optical aberration of peripheral vision caused by oblique incidence of rays striking the refracting surfaces of the cornea and crystalline lens. We inquired whether oblique astigmatism from these two sources should be expected, theoretically, to have the same or opposite signs across the visual field at various states of accommodation. Methods Oblique astigmatism was computed across the central visual field for a rotationally-symmetric schematic-eye using optical design software. Accommodative state was varied by altering the apical radius of curvature and separation of the biconvex lens’s two aspheric surfaces in a manner consistent with published biometry. Oblique astigmatism was evaluated separately for the whole eye, the cornea, and the isolated lens over a wide range of surface curvatures and asphericity values associated with the accommodating lens. We also computed internal oblique astigmatism by subtracting corneal oblique astigmatism from whole-eye oblique astigmatism. Results A visual field map of oblique astigmatism for the cornea in the Navarro model follows the classic, textbook description of radially-oriented axes everywhere in the field. Despite large changes in surface properties during accommodation, intrinsic astigmatism of the isolated human lens for collimated light is also radially oriented and nearly independent of accommodation both in theory and in real eyes. However, the magnitude of ocular oblique astigmatism is smaller than that of the cornea alone, indicating partial compensation by the internal optics. This implies internal oblique astigmatism (which includes wavefront propagation from the posterior surface of the cornea to the anterior surface of the lens and intrinsic lens astigmatism) must have tangentially-oriented axes. This non-classical pattern of tangential axes for internal astigmatism was traced to the influence of corneal power on the angles of incidence of rays striking the internal lens. Conclusions Partial compensation of corneal astigmatism by internal optics is due mainly to the highly converging nature of wavefronts incident upon the lens resulting from corneal refraction. The degree of compensation is quadratically dependent on eccentricity but is expected to diminish as the eye accommodates. Neutralising the cornea by index-matching defeats internal compensation, revealing classical, radially-oriented oblique astigmatism in the isolated lens. PMID:28281302

  20. Ural Eye and Medical Study: description of study design and methodology.

    PubMed

    Bikbov, Mukharram; Fayzrakhmanov, Rinat R; Kazakbaeva, Gyulli; Jonas, Jost B

    2018-06-01

    Since there is a scarcity on population-based health information available for Russia, we conducted this project to assess the prevalence of major ocular and systemic disorders and their associated risk factors. A population-based cross-sectional study (Ural Eye and Medical Study (UEMS)) was performed in Bashkortostan 1300 km east of Moscow. The sampling frame consisted of all inhabitants aged over 40 years and living in an urban study area in the capital city Ufa and a rural region at 65 km outside of Ufa. The target sample size was 2500 individuals for the urban region and 2500 persons for the rural region. The study participants underwent a detailed interview, a detailed ophthalmologic examination including biometry and optical coherence tomography, and clinical examination including assessment of electrocardiography, hearing test, blood sampling, spirometry, and hand grip dynamometry. After a first study period, the study population included 4254 individuals with a mean age of 60.3 ± 11.1 years (range: 40-94 years), mean body weight of 74.8 ± 14.4 kg (range: 31-170 kg), body height of 163.6 ± 8.9 cm (range: 112-196), body mass index of 28.0 ± 5.1 kg/m 2 (range: 13.96-60.96 kg/m 2 ), mean systolic blood pressure of 133.7 ± 21.0 mmHg (range: 84-232 mmHg), and mean diastolic blood pressure of 81.2 ± 10.6 mmHg (range: 40-134 mmHg). Mean refractive error was -0.21 ± 1.94 D and mean intraocular pressure was 13.6 ± 3.9 mmHg. The UEMS provides population-based normative data for a Russian region on the quantitative traits such as axial length, quality of life and lifestyle including smoking and alcohol consumption, and prevalence and risk factors of ocular and systemic diseases such as diabetes mellitus, arterial hypertension, chronic obstructive pulmonary disease, and depression.

  1. Association of brain metabolism with sulcation and corpus callosum development assessed by MRI in late-onset small fetuses.

    PubMed

    Sanz-Cortes, Magdalena; Egaña-Ugrinovic, Gabriela; Simoes, Rui V; Vazquez, Lucia; Bargallo, Nuria; Gratacos, Eduard

    2015-06-01

    We sought to determine the relationship between fetal brain metabolism and microstructure expressed by brain sulcation, and corpus callosum (CC) development assessed by fetal brain magnetic resonance (MR) imaging and proton MR spectroscopy ((1)H-MRS). A total of 119 fetuses, 64 that were small for gestational age (estimated fetal weight <10th centile and normal umbilical artery Doppler) and 55 controls underwent a 3T MR imaging/(1)H-MRS exam at 37 weeks. Anatomical T2-weighted images were obtained in the 3 orthogonal planes and long echo time (TE) (1)H-MRS acquired from the frontal lobe. Head biometrics, cortical fissure depths (insula, Sylvian, parietooccipital, cingulate, and calcarine), and CC area and biometries were blindly performed by manual and semiautomated delineation using Analyze software and corrected creating ratios for biparietal diameter and frontooccipital diameter, respectively, for group comparison. Spectroscopic data were processed using LCModel software and analyzed as metabolic ratios of N-acetylaspartate (NAA) to choline (Cho), Cho to creatine (Cr), and myo-inositol (Ino) to Cho. Differences between cases and controls were assessed. To test for the association between metabolic ratios and microstructural parameters, bivariate correlation analyses were performed. Spectroscopic findings showed decreased NAA/Cho and increased Cho/Cr ratios in small fetuses. They also presented smaller head biometrics, shorter and smaller CC, and greater insular and cingulate depths. Frontal lobe NAA/Cho significantly correlated with biparietal diameter (r = 0.268; P = .021), head circumference (r = 0.259; P = .026), CC length (r = 0.265; P = .026), CC area (r = 0.317; P = .007), and the area of 6 from the 7 CC subdivisions. It did not correlate with any of the cortical sulcation parameters evaluated. None of the other metabolic ratios presented significant correlations with cortical development or CC parameters. Frontal lobe NAA/Cho levels-which are considered a surrogate marker of neuronal activity-show a strong association with CC development. These results suggest that both metabolic and callosal alterations may be part of the same process of impaired brain development associated with intrauterine growth restriction. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Simplified 4-item criteria for polycystic ovary syndrome: A bridge too far?

    PubMed

    Indran, Inthrani R; Huang, Zhongwei; Khin, Lay Wai; Chan, Jerry K Y; Viardot-Foucault, Veronique; Yong, Eu Leong

    2018-05-30

    Although the Rotterdam 2003 polycystic ovarian syndrome (PCOS) diagnostic criteria is widely used, the need to consider multiple variables makes it unwieldy in clinical practice. We propose a simplified PCOS criteria wherein diagnosis is made if two of the following three items were present: (i) oligomenorrhoea, (ii) anti-mullerian hormone (AMH) above threshold and/or (iii) hyperandrogenism defined as either testosterone above threshold and/or the presence of hirsutism. This prospective cross-sectional study consists of healthy women (n = 157) recruited at an annual hospital health screen for staff and volunteers from the university community, and a patient cohort (n = 174) comprising women referred for suspected PCOS. We used the healthy cohort to establish threshold values for serum testosterone, antral follicle counts (AFC), ovarian volume (OV) and AMH. Women from the patient cohort, classified as PCOS by simplified PCOS criteria, AMH alone and Rotterdam 2003, were compared with respect to prevalence of oligomenorrhoea, hyperandrogenism and metabolic indices. In healthy women, testosterone ≥1.89 nmol/L, AFC ≥22 follicles and OV ≥8.44 mL, best predicted oligomenorrhoea and were used as threshold values for PCOS criteria. An AMH level ≥37.0 pmol/L best predicted polycystic ovarian morphology. AMH alone as a single biomarker demonstrated poor specificity (58.9%) for PCOS compared to Rotterdam 2003. In contrast, there was a 94% overlap in women selected as PCOS by the simplified PCOS criteria and Rotterdam 2003. The population characteristics of these two groups of PCOS women showed no significant mean differences in androgenic, ovarian, AMH and metabolic (BMI, HOMA-IR) variables. Our data recommend the simplified PCOS criteria with population-specific thresholds for diagnosis of PCOS. Its ability to replace ovarian ultrasound biometry with the highly correlated variable AMH, and use of testosterone as a single marker for hyperandrogenaemia alongside the key symptoms of oligomenorrhoea and hirsutism confers significant clinical potential for the diagnosis of PCOS. © 2018 John Wiley & Sons Ltd.

  3. The how and why of a $10 optical coherence tomography system

    NASA Astrophysics Data System (ADS)

    Leahy, M. J.; Wilson, C.; Hogan, J.; O'Brien, Peter; Dsouza, R.; Neuhaus, K.; Bogue, D.; Subhash, H.; O'Riordan, Colm; McNamara, Paul M.

    2016-03-01

    Optical Coherence Tomography (OCT) is the fastest growing medical imaging modality with more than 1Bln worth of scans ordered and over 400M worth of equipment shipped in 2010, just nine years after its commercialization. It is at various stages of acceptance and approvals for eye care, coronary care and skin cancer care and is spreading rapidly to other medical specialties. Indeed, it is the leading success of translation of biophotonics science into clinical practice. Significant effort is being made to provide sufficient evidence for efficacy across a broad range of applications, but more needs to be done to radically reduce the cost of OCT so that it can spread to underserved markets and address new, fast growing opportunities in mobile health monitoring. Currently, a clinical OCT system ranges in price from 50k to 150k, typically is housed on a bedside trolley, runs off AC power, and requires skilled, extensively trained technicians to operate. The cost, size, and skill level required keep this wonderful technology beyond the reach of mainstream primary care, much less individual consumers seeking to monitor their health on a routine basis outside of typical clinical settings and major urban medical centers. Beyond the first world market, there are 6.5 billion people with similar eye and skin cancer care needs which cannot be met by the current generation of large, expensive, complex, and delicate OCT systems. This paper will describe a means to manufacture a low cost, compact, simple, and robust OCT system, using parts and a configuration similar to a CD-ROM or DVD pickup unit (see figure 1). Essentially, this system—multiple reference OCT (MR-OCT)—is based on the use of a partial mirror in the reference arm of a time domain OCT system to provide multiple references, and hence A-scans, at several depths simultaneously (see figure 2). We have already shown that a system based on this configuration can achieve an SNR of greater than 90 dB, which is sufficient for many medical imaging and biometry applications.

  4. Salinity reduction benefits European eel larvae: Insights at the morphological and molecular level.

    PubMed

    Politis, Sebastian N; Mazurais, David; Servili, Arianna; Zambonino-Infante, Jose-Luis; Miest, Joanna J; Tomkiewicz, Jonna; Butts, Ian A E

    2018-01-01

    European eel (Anguilla anguilla) is a euryhaline species, that has adapted to cope with both, hyper- and hypo-osmotic environments. This study investigates the effect of salinity, from a morphological and molecular point of view on European eel larvae reared from 0 to 12 days post hatch (dph). Offspring reared in 36 practical salinity units (psu; control), were compared with larvae reared in six scenarios, where salinity was decreased on 0 or 3 dph and in rates of 1, 2 or 4 psu/day, towards iso-osmotic conditions. Results showed that several genes relating to osmoregulation (nkcc2α, nkcc2β, aqp1dup, aqpe), stress response (hsp70, hsp90), and thyroid metabolism (thrαA, thrαB, thrβB, dio1, dio2, dio3) were differentially expressed throughout larval development, while nkcc1α, nkcc2β, aqp3, aqp1dup, aqpe, hsp90, thrαA and dio3 showed lower expression in response to the salinity reduction. Moreover, larvae were able to keep energy metabolism related gene expression (atp6, cox1) at stable levels, irrespective of the salinity reduction. As such, when reducing salinity, an energy surplus associated to reduced osmoregulation demands and stress (lower nkcc, aqp and hsp expression), likely facilitated the observed increased survival, improved biometry and enhanced growth efficiency. Additionally, the salinity reduction decreased the amount of severe deformities such as spinal curvature and emaciation but also induced an edematous state of the larval heart, resulting in the most balanced mortality/deformity ratio when salinity was decreased on 3 dph and at 2 psu/day. However, the persistency of the pericardial edema and if or how it represents an obstacle in further larval development needs to be further clarified. In conclusion, this study clearly showed that salinity reduction regimes towards iso-osmotic conditions facilitated the European eel pre-leptocephalus development and revealed the existence of highly sensitive and regulated osmoregulation processes at such early life stage of this species.

  5. [Social medicine in medical faculties: realisation of the topic in the specialty "social medicine, occupational health"].

    PubMed

    Behmann, M; Bisson, S; Walter, U

    2011-12-01

    The 9 (th) Revision of German Medical Licensing Regulations for Physicians has come into effect on October 1 (st) 2003. Social medicine was separated into the fields "occupational health, social medicine" and the various cross-sectional modules: epidemiology, biometry, medical computer science; health economics, health-care system, public health; prevention, health promotion; rehabilitation, physical medicine, naturopathic treatment. This paper studies the realisation of teaching in the field social medicine at German medical faculties. The survey was conducted in collaboration with the German Association for Social Medicine and Prevention (DGSMP). A survey was conducted at 38 institutes of 36 German medical faculties. The written questionnaire contained mostly selection items in which chances and barriers of the field were queried with supply items. Information about time scale, general conditions and resources was aked for. On the basis of the guidelines of the DGSMP, the topics to be taught were evaluated concerning their relevance and integration into education. The response rate was 68% (n=26). Social insurance, basic principles, responsibility in the Social Security Code and the different providers were judged as the most important topics. There was a strong demand for lecturing material. 82% (n=18) of the faculties wished to have specific material, for example e-learning, examples, lesson plans, curricula and also textbooks. 91% (n=19) of the faculties requested an exchange of information between the faculties concerning educational contents, motivation of students and e-learning. The realisation of teaching is different between the faculties concerning the number of hours, teaching methods and number of students per year. The motivation of the students is one of the problems, but also the lack of acceptance within the clinic. Specific resources and exchange between the faculties are necessary concerning e-learning, which is offered at only few faculties so far, but interest for a more intensive usage exists. Potentials of social medicine are the promotion of awareness among the students and the "identification of basics for medical acts in the social security system". Social medicine offers the possibility to connect the theoretical institutes with the clinic. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Implementing the INTERGROWTH-21st fetal growth standards in France: a 'flash study' of the College Français d'Echographie Foetale (CFEF).

    PubMed

    Stirnemann, J J; Fries, N; Bessis, R; Fontanges, M; Mangione, R; Salomon, L J

    2017-04-01

    To assess potential differences in fetal size between the French population and the international population from the INTERGROWTH-21 st (IG-21 st ) Project and to measure the impact of switching to the IG-21 st reference standards for fetal size. This was a nationwide cross-sectional study of fetal ultrasound biometry. Low-risk singleton pregnancies were recruited prospectively within the network of the national French College of Fetal Ultrasound, CFEF, over a 6-week period. Further selection was performed based on the criteria of the IG-21 st Project in order to obtain a comparable population. Head circumference (HC) was used as the main fat-free skeletal measure of growth for comparison of French fetal size with that of the IG-21 st population. The impact of switching to the IG-21 st fetal growth standards was quantified by comparing Z-scores calculated using the IG-21 st standards with those calculated using locally derived reference ranges for HC, abdominal circumference (AC) and femur length (FL). Following selection, 4858 cases were analyzed. The distribution of HC demonstrated clear similarity between our French population and the IG-21 st population: our observed centile curves closely matched those of IG-21 st and the Z-scores were close to 0 across gestational age. The IG-21 st standards performed as well as did locally derived charts in terms of screening for small-for-gestational age by AC, while they identified significantly fewer small FL values than were expected and than did the locally derived charts. Under strict selection criteria, fetal size in France is similar to that of the international population used in the IG-21 st Project. The discrepancies in FL are unlikely to impact on prenatal management. Therefore, switching from locally derived reference ranges to the IG-21 st standards appears to be a safe option. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  7. Modeling of mouse eye and errors in ocular parameters affecting refractive state

    NASA Astrophysics Data System (ADS)

    Bawa, Gurinder

    Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse eye and suggest that extra efforts should be directed towards increasing the linear resolution of the rodent eye biometry and obtaining more accurate data for the refractive indices of the lens and vitreous.

  8. Age, Gender, Biometry, Refractive Error, and the Anterior Chamber Angle among Alaskan Eskimos

    PubMed Central

    Wojciechowski, Robert; Congdon, Nathan; Anninger, William; Broman, Aimee Teo

    2011-01-01

    Background The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency. Methods A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161–7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects. Results Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond. Conclusions Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher prevalence of myopia and resulting wider angles among younger Eskimos and Chinese. PMID:12578783

  9. Comparison of ultrasound biomicroscopy and ultrasonographic parameters in eyes with phacomorphic glaucoma and eyes with mature cataract.

    PubMed

    Subbiah, Sujata; Thomas, Philip A; Nelson Jesudasan, C A

    2017-08-01

    To compare data on anatomical and biometric parameters, and their combination, obtained by using ultrasound biomicroscopy (UBM) and A-scan in eyes with phacomorphic glaucoma (PG) and eyes with mature cataract and to determine differences that may predispose to development of PG. Eighty patients (80 eyes) were enrolled in this cross-sectional study. Anterior chamber parameters, namely anterior chamber depth (ACD), angle-opening distance (AOD), iris-lens contact distance (ILCD), and trabecular-ciliary process distance (TCPD), among other parameters, were assessed by UBM (35 MHz), while axial length (AL) and lenticular thickness (LT) were determined by A-scan biometry. Absolute lenticular position (ALP) and relative lenticular position (RLP) were also compared. The mean AL of eyes with PG was less (P = 0.64) than the mean AL of eyes with mature cataract. The mean ILCD value in eyes with PG (1.30 ± 0.78 mm) was significantly higher (P = 0.0015) than that in eyes with mature cataract (0.86 ± 0.32 mm). The mean AOD value in eyes with PG (0.15 ± 0.10 mm) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.23 ± 0.06 mm); similarly, the mean RLP value in eyes with PG (0.20 ± 0.02) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.17 ± 0.02). TCPD showed negative correlation with LT r = -0.514; P = 0.017, r 2  = 0.264, in eyes with phacomorphic glaucoma and mature cataracts showed significant negative correlation of ILCD with AL (r = -0.575; P = 0.025, r 2  = 0.330). The results of UBM examination suggest that there are multiple mechanisms underlying the pathophysiology of PG, namely crowding of the anterior segment, increased iris-lens contact distance, and a more pronounced anterior shift of the lens. Simultaneous evaluation of anatomic and biometric parameters can improve diagnostic accuracy in predicting cases at risk for PG.

  10. Maternal Administration of Sildenafil Citrate Alters Fetal and Placental Growth and Fetal-Placental Vascular Resistance in the Growth-Restricted Ovine Fetus.

    PubMed

    Oyston, Charlotte; Stanley, Joanna L; Oliver, Mark H; Bloomfield, Frank H; Baker, Philip N

    2016-09-01

    Intrauterine growth restriction (IUGR) causes short- and long-term morbidity. Reduced placental perfusion is an important pathogenic component of IUGR; substances that enhance vasodilation in the uterine circulation, such as sildenafil citrate (sildenafil), may improve placental blood flow and fetal growth. This study aimed to examine the effects of sildenafil in the growth-restricted ovine fetus. Ewes carrying singleton pregnancies underwent insertion of vascular catheters, and then, they were randomized to receive uterine artery embolization (IUGR) or to a control group. Ewes in the IUGR group received a daily infusion of sildenafil (IUGR+SC; n=10) or vehicle (IUGR+V; n=8) for 21 days. The control group received no treatment (n=9). Umbilical artery blood flow was measured using Doppler ultrasound and the resistive index (RI) calculated. Fetal weight, biometry, and placental weight were obtained at postmortem after treatment completion. Umbilical artery RI in IUGR+V fell less than in controls; the RI of IUGR+SC was intermediate to that of the other 2 groups (mean±SEM for control versus IUGR+V versus IUGR+SC: ∆RI, 0.09±0.03 versus -0.01±0.02 versus 0.03±0.02; F(2, 22)=4.21; P=0.03). Compared with controls, lamb and placental weights were reduced in IUGR+V but not in IUGR+SC (control versus IUGR+V versus IUGR+SC: fetal weight, 4381±247 versus 3447±235 versus 3687±129 g; F(2, 24)=5.49; P=0.01 and placental weight: 559.7±35.0 versus 376.2±32.5 versus 475.2±42.5 g; F(2, 24)=4.64; P=0.01). Sildenafil may be a useful adjunct in the management of IUGR. An increase in placental weight and fall in fetal-placental resistance suggests that changes to growth are at least partly mediated by changes to placental growth rather than alterations in placental efficiency. © 2016 American Heart Association, Inc.

  11. [Labor induction with extra-amnial administration of PGE2 vaginal tablets].

    PubMed

    Roztocil, A; Koudelka, M; Jelínek, J; Miklica, J; Pilka, L

    1996-08-01

    During the period between Jan. 1 1992 and Dec. 31, 1995 at the Second Department of Gynaecology and Obstetrics in Brno labour was induced in 1159 patients by extraamnial fractionated administration of PGE2 vaginal tablets. After assessment of the indication and the baseline examination (NST, amnioscopy, US biometry and cervical score) according to the CS to the patient the first dose of PGE2 was administered into the extraamnial space beyond the inner os uteri (CS 5-8:1.0 mg PGE2, CS > 8 : 0.5 mg PGE2). After two hours the patient was examined again and if regular uterine contractions had started or the finding on the os uteri was larger than 2 cm, the amniotic sac was disrupted. If not, another dose was administered. After two hours the patient was re-examined and if the os was larger than 2 cm, and there were regular uterine contractions, the amniotic sac was disrupted. If the changes did not take place, the induction was considered a failure. there were 1007 successful inductions (95.5%), the mean period from the onset of induction to the onset of uterine contractions was < 120 mins-269 (24.6%), 120-180 mins.: 501 (45.9%) and > 180 mins.: 322 (29.5%). The mean period of the first stage of labour was 228 mins., stage II 10 mins., stage III 8 mins. Five times uterine hypertonus was recorded and a blood loss greater than 500 ml occurred in four patients. Forty-nine Caesarean sections were made (4.2%) and 51 (4.4%) forceps deliveries. The rate of epidural analgesia was 27 (2.3%). Revision of the uterine cavity was made in 39 patients (3.4%) and manual lysis of the placenta in 30 (2.6%). The Apgar score was inferior to 6 in 10 neonates (0.9%). The protocol of induction of labour described by the authors is effective and associated with a minimum of side-effects, safe for the mother and foetus, well tolerated by patients and cost-effective.

  12. Effectiveness of combined macular buckle under direct vision and vitrectomy with ILM peeling in refractory macular hole retinal detachment with extreme high axial myopia: a 24-month comparative study.

    PubMed

    Ma, Jin; Li, Honghui; Ding, Xiaohu; Tanumiharjo, Silvia; Lu, Lin

    2017-10-01

    To evaluate the efficacy of a combined macular buckle under direct vision and 23-gauge pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling in refractory macular hole retinal detachment (MHRD) with extreme high axial myopia. Prospective, randomised controlled study. The study included 98 eyes of 98 patients of MHRD with extreme high axial (>30 mm) myopia. Patients were randomly assigned to undergo PPV with ILM peeling (group 1, n=52) or PPV with ILM peeling combined with macular buckle under direct vision (group 2, n=46). Complete ocular examination included best-corrected visual acuity (BCVA) (LogMAR), applanation tonometry, optical biometry, slit-lamp biomicroscopy, colour fundus photography, ultrasound examination and optical coherence tomography at baseline and every follow-up visit. Initial retinal reattachment rate was significantly higher in group 2 than in group 1 at 12-month postoperatively (χ 2 test, p=0.020). Macular hole closure rate in group 2 was significantly higher than that in group 1 at 3, 12, 18 and 24 months postoperatively (Fisher's exact test, p<0.05). In initial retinal reattachment cases, the mean BCVA decreased significantly in group 2 than in group 1 at 3 months postoperatively (Wilcoxon matched pairs signed rank test, p=0.036), and had increased significantly in group 2 than in group 1 since 6 months postoperatively (Wilcoxon matched pairs signed rank test, p<0.05). Mean axial lengths in group 2 were significantly shorter than that of group 1 at each follow-up time point (Wilcoxon matched pairs signed rank test, p<0.05). Combined macular buckle under direct vision and PPV with ILM peeling is more effective in treatment of MHRD with extreme high axial (>30 mm) myopia. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Anterior segment biometry during accommodation imaged with ultra-long scan depth optical coherence tomography

    PubMed Central

    Du, Chixin; Shen, Meixiao; Li, Ming; Zhu, Dexi; Wang, Michael R.; Wang, Jianhua

    2012-01-01

    Purpose To measure by ultra-long scan depth optical coherence tomography (UL-OCT) dimensional changes in the anterior segment of human eyes during accommodation. Design Evaluation of diagnostic test or technology. Participants Forty-one right eyes of healthy subjects with a mean age of 34 years (range, 22–41 years) and a mean refraction of −2.5±2.6 diopters (D) were imaged in two repeated measurements at minimal and maximal accommodation. Methods A specially adapted designed UL-OCT instrument was used to image from the front surface of the cornea to the back surface of the crystalline lens. Custom software corrected the optical distortion of the images and yielded the biometric measurements. The coefficient of repeatability (COR) and the intraclass correlation coefficient (ICC) were calculated to evaluate the repeatability and reliability. Main Outcome Measures Anterior segment parameters and associated repeatability and reliability upon accommodation. The dimensional results included central corneal thickness (CCT), anterior chamber depth and width (ACD, ACW), pupil diameter (PD), lens thickness (LT), anterior segment length (ASL=ACD+LT), lens central position (LCP=ACD+1/2LT) and horizontal radii of the lens anterior and posterior surface curvatures (LAC, LPC). Results Repeated measurements of each variable within each accommodative state did not differ significantly (P>0.05). The CORs and ICCs for CCT, ACW, ACD, LT, LCP, and ASL were excellent (1.2% to 3.59% and 0.998 to 0.877, respectively). They were higher for PD (18.90% to 21.63% and 0.880 to 0.874, respectively), and moderate for LAC and LPC (34.86% to 42.72% and 0.669 to 0.251, respectively) in the two accommodative states. Compared to minimal accommodation, PD, ACD, LAC, LPC, and LCP decreased and LT and ASL increased significantly at maximal accommodation (P<0.05), while CCT and ACW did not change (P>0.05). Conclusions UL-OCT measured changes in anterior segment dimensions during accommodation with good repeatability and reliability. During accommodation, the back surface of the lens became steeper as the lens moved forward. PMID:22902211

  14. Revealed versus concealed criteria for placental insufficiency in an unselected obstetric population in late pregnancy (RATIO37): randomised controlled trial study protocol.

    PubMed

    Figueras, Francesc; Gratacos, Eduard; Rial, Marta; Gull, Ilan; Krofta, Ladislav; Lubusky, Marek; Cruz-Martinez, Rogelio; Cruz-Lemini, Mónica; Martinez-Rodriguez, Miguel; Socias, Pamela; Aleuanlli, Cristina; Cordero, Mauro C Parra

    2017-06-15

    Fetal growth restriction (FGR) affects 5%-10% of all pregnancies, contributing to 30%-50% of stillbirths. Unfortunately, growth restriction often is not detected antenatally. The last weeks of pregnancy are critical for preventing stillbirth among babies with FGR because there is a pronounced increase in stillbirths among growth-restricted fetuses after 37 weeks of pregnancy. Here we present a protocol (V.1, 23 May 2016) for the RATIO37 trial, which evaluates an integrated strategy for accurately selecting at-risk fetuses for delivery at term. The protocol is based on the combination of fetal biometry and cerebroplacental ratio (CPR). The primary objective is to reduce stillbirth rates. The secondary aims are to detect low birth weights and adverse perinatal outcomes. The study is designed as multicentre (Spain, Chile, Mexico,Czech Republic and Israel), open-label, randomised trial with parallel groups. Singleton pregnancies will be invited to participate after routine second-trimester ultrasound scan (19 +0 -22 +6 weeks of gestation), and participants will be randomly allocated to receive revealed or concealed CPR evaluation. Then, a routine ultrasound and Doppler scan will be performed at 36 +0 -37 +6 weeks. Sociodemographic and clinical data will be collected at enrolment. Ultrasound and Doppler variables will be recorded at 36 +0 -37 +6 weeks of pregnancy. Perinatal outcomes will be recorded after delivery. Univariate (with estimated effect size and its 95% CI) and multivariate (mixed-effects logistic regression) comparisons between groups will be performed. The study will be conducted in accordance with the principles of Good Clinical Practice. This study was accepted by the Clinical Research Ethics Committee of Hospital Clinic Barcelona on 23May 2016. Subsequent approval by individual ethical committees and competent authorities was granted. The study results will be published in peer-reviewed journals and disseminated at international conferences. NCT02907242; pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Risk factors for open-angle glaucoma in Nigeria: results from the Nigeria National Blindness and Visual Impairment Survey.

    PubMed

    Kyari, Fatima; Abdull, Mohammed M; Wormald, Richard; Evans, Jennifer R; Nolan, Winifred; Murthy, Gudlavelleti V S; Gilbert, Clare E

    2016-06-07

    The glaucoma-specific blindness prevalence in Nigeria (0.7 %, 95 % CI 0.6-0.9 %) among those aged ≥40 years is one of the highest ever reported. This study determined the risk factors for open-angle glaucoma (OAG) in adults examined in the Nigeria National Blindness and Visual Impairment Survey. A nationally representative sample of 13,591 people aged ≥40 years in 305 clusters in Nigeria were examined (response rate 90.4 %) between January 2005 to June 2007. Everyone had logMAR visual acuity measurement, Frequency Doubling Technology (FDT) visual field testing, autorefraction, A-scan biometry and optic disc assessment. Full ocular examination (n = 6397), included Goldmann applanation tonometry. Values for defining glaucoma using International Society of Geographical and Epidemiological Ophthalmology criteria were derived from the study population. Disc images were graded by Moorfields Eye Hospital Reading Centre. Socio-demographic factors (age, gender, ethnicity, literacy and place of residence), ocular parameters (intraocular pressure [IOP], axial length and mean ocular perfusion pressure [MOPP]) and systemic parameters (blood pressure, blood glucose and body mass index [BMI]) were assessed for association with OAG. Thirteen thousand eighty-one (96 %) of 13,591 participants had vertical cup:disc ratio measured in at least one eye. 682 eyes of 462 participants were classified as OAG, with 12,738 controls. In univariate analyses the following were associated with OAG: increasing age, male gender, Igbo and Yoruba ethnic groups, illiteracy, longer axial length, higher IOP, lower MOPP, greater severity of hypertension and low BMI (underweight). In multivariate analysis, increasing age (odds ratio [OR] 1.04, 95 % CI 1.03-1.05), higher IOP (OR 1.22, 95 % CI 1.18-1.25) and Igbo ethnicity (OR 1.73, 95 % CI 1.18-2.56) were independent risk factors for OAG. Case detection strategies for OAG should be improved for those aged ≥40 years and for ethnic groups most at risk as a public health intervention.

  16. Basic as well as detailed neurosonograms can be performed by offline analysis of three-dimensional fetal brain volumes.

    PubMed

    Bornstein, E; Monteagudo, A; Santos, R; Strock, I; Tsymbal, T; Lenchner, E; Timor-Tritsch, I E

    2010-07-01

    To evaluate the feasibility and the processing time of offline analysis of three-dimensional (3D) brain volumes to perform a basic, as well as a detailed, targeted, fetal neurosonogram. 3D fetal brain volumes were obtained in 103 consecutive healthy fetuses that underwent routine anatomical survey at 20-23 postmenstrual weeks. Transabdominal gray-scale and power Doppler volumes of the fetal brain were acquired by one of three experienced sonographers (an average of seven volumes per fetus). Acquisition was first attempted in the sagittal and coronal planes. When the fetal position did not enable easy and rapid access to these planes, axial acquisition at the level of the biparietal diameter was performed. Offline analysis of each volume was performed by two of the authors in a blinded manner. A systematic technique of 'volume manipulation' was used to identify a list of 25 brain dimensions/structures comprising a complete basic evaluation, intracranial biometry and a detailed targeted fetal neurosonogram. The feasibility and reproducibility of obtaining diagnostic-quality images of the different structures was evaluated, and processing times were recorded, by the two examiners. Diagnostic-quality visualization was feasible in all of the 25 structures, with an excellent visualization rate (85-100%) reported in 18 structures, a good visualization rate (69-97%) reported in five structures and a low visualization rate (38-54%) reported in two structures, by the two examiners. An average of 4.3 and 5.4 volumes were used to complete the examination by the two examiners, with a mean processing time of 7.2 and 8.8 minutes, respectively. The overall agreement rate for diagnostic visualization of the different brain structures between the two examiners was 89.9%, with a kappa coefficient of 0.5 (P < 0.001). In experienced hands, offline analysis of 3D brain volumes is a reproducible modality that can identify all structures necessary to complete both a basic and a detailed second-trimester fetal neurosonogram. Copyright 2010 ISUOG. Published by John Wiley & Sons, Ltd.

  17. Effect of Ramadan fasting in tropical summer months on ocular refractive and biometric characteristics.

    PubMed

    Nowroozzadeh, Mohammad Hosein; Mirhosseini, Amirhossein; Meshkibaf, Mohammad Hassan; Roshannejad, Javad

    2012-03-01

    Islamic Ramadan is the month of fasting, in which intake of food and drink is restricted from sunrise until sunset. The objective of the present study was to find out the effect of altered eating habits during Ramadan fasting on ocular refractive and biometric properties. In this prospective case series, 40 eyes of 22 healthy volunteers with a mean age of 60.55 ± 12.20 years were enrolled. Patients with any systemic disorder and eyes with pathology or previous surgery were excluded. One month before Ramadan (at 8.00 am), during Ramadan fasting (at 8.00 am and 4.00 pm) and one month later during the non-fasting period (at 8.00 am), ocular refractive and biometric characteristics were measured using an autokeratorefractometer (Auto-Kerato-Refractometer KR-8900; Topcon Co, Tokyo, Japan) and contact ultrasonic biometry (Nidek Echoscan US 800; Nidek Co, Tokyo, Japan). Anterior chamber depth was significantly increased during fasting compared with baseline measurements and returned to baseline one month after Ramadan (3.22 ± 0.07 mm and 4.33 ± 0.17 mm for non-fasting and fasting, respectively; p < 0.001). The anterior chamber depth measurements were significantly larger at 8.00 am during fasting compared with 4.00 pm (p = 0.01). Axial length was significantly decreased during fasting and returned to baseline one month after Ramadan (23.09 ± 0.14 mm and 22.65 ± 0.18 mm, for non-fasting and fasting, respectively; p < 0.001). Intraocular lens power calculations were significantly increased during fasting and returned to baseline one month after Ramadan (SRK-T formula: 21.46 ± 0.27 D and 22.92 ± 0.46 D, for non-fasting and fasting, respectively; p < 0.001). There were no significant differences in spherical equivalent, corneal astigmatism, mean keratometry and flatter and steeper corneal radii of curvature between time intervals. Ramadan fasting is associated with statistically significant alterations in anterior chamber depth and axial length that result in both statistically and clinically significant changes in intraocular lens power calculations. Therefore, relying on measurements taken during this month might lead to refractive errors after cataract surgery. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

  18. Prenatal development of the agouti (Dasyprocta prymnolopha Wagler, 1831): External features and growth curves.

    PubMed

    Fortes, Eunice Anita de Moura; Ferraz, Maíra Soares; Bezerra, Dayseanny Oliveira; Júnior, Aírton Mendes Conde; Cabral, Rosa Maria; Sousa, Francisco das Chagas Araújo; Almeida, Hatawa Melo; Pessoa, Gerson Tavares; Menezes, Danilo José Ayres de; Guerra, Sérgio Paulo Lima; Sampaio, Ivan Barbosa Machado; Assis Neto, Antônio Chaves; Carvalho, Maria Acelina Martins de

    2013-08-01

    The gestation period in agoutis can range from 104 to 120 days. Knowledge regarding the morphological characteristics of embryos and fetuses is important as a base for studies in reproduction biotechnology, such as in vitro fertilization, embryo transfer and helps in determining congenital anomalies during the development phase. Thus, given the importance and lack of information about agouti embryology, the objective of this study was to characterize the external morphology and define the biometry of embryos and fetuses, at different days of development. Nine females were submitted to daily colpocytology to identify the estrus, confirm mating and identify day zero of the gestation. When the mating was confirmed they were weighed, underwent abdominal ultrasonography and surgery was conducted on the females at the gestational ages of 25, 30, 35, 40, 45, 50, 75 and 100 days. Sixteen embryos/fetuses were weighed and measured. Agouti embryos at 25 days after mating are "C" shaped, with primitive structures, 0.4±0.01cm crown-rump and weighed 0.06±0.01g; at 30 days after mating the crown-rump was 0.95±0.07cm and weighed 0.28±0.00g; at 35 days after mating the crown-rump was 155±0.07cm and weighed 0.38±0.01g; at 40 days after mating the crown-rump was 2.25±0.21cm and weighed 1.25±0.07g; at 45 days after mating the crown-rump was 3.45±0.35cm and weighed 2.75±0.64g; at 50 days after mating the crown-rump was 5.0±0.3cm and weighed 7.01±2.6g; at 75 days after mating, the skin was dark, the crown-rump was 10.0±0.14cm and weighed 55.2±0.07g. At 100 days after mating, the crown-rump was 13.8±0.49cm and fetuses weighed 136.7±9.40g. Based on the morphological data assessed the embryo and fetus age could be assessed and the size and average weight of agouti embryos was established. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Long -term effects of optical defocus on eye growth and refractogenesis.

    PubMed

    Tarutta, Elena; Khodzhabekyan, Narine; Filinova, Oksana; Milash, Sergei; Kruzhkova, Galina

    The aim of this paper was to study the effect of binocular and alternating monocular myopic constant defocus prescribed in spectacle format on myopia onset and progression in children. 129 children aged 5–12 years were divided into 4 groups: 48 children aged 5–8 years (1st group) with emmetropia and risk factors of myopia development were prescribed the continuous wearing of plus lenses to induce myopia of 1.0 D. 46 children aged 7–11 years (2nd group) with low myopia from −0.75 to −2.25 D were prescribed 2 pairs of spectacles for alternating continuous wearing. One eye was corrected for distance to obtain residual myopia in spectacles of about 0.50 D, and the fellow eye was corrected to obtain residual or induced myopia of about 1.50 D. The children changed spectacles every day. Control data were obtained from 15 children aged 6–9 years (1st control group) with pseudomyopia with no correction administered, and 20 low myopic children aged 7–12 years (2nd control group) wearing conventional spectacle correction. Autorefractometry before and after cycloplegia and ultrasound biometry were performed. A hyperopic shift caused by thinning of the crystalline lens and deepening of the anterior chamber in all patients of the 1st group was observed after 1 month and persisted over the follow -up period. Horizontal diameter (HD) increased more than 3 times as much as the axial length (AL). No cases of myopia onset were observed during the 9 -year follow -up period. 36 (81.8%) children of the 2nd group had stable refraction over the 4 year follow up, an insignificant increase in the AL and a significant increase in the HD were revealed. A 3-year follow -up revealed an increase in cycloplegic refraction in both control groups; the AL increased significantly, while the HD showed an insignificant increase. Permanent low myopic defocus of the image in binocular spectacle format inhibits eye growth and refraction shift to myopia in children with low hyperopia, emmetropia and low myopia. The method of alternating monolateral low myopic defocus arrests the myopia progression in 81.8% of children with low myopia for 4 years and 66% for 7 years.

  20. EVERREST prospective study: a 6-year prospective study to define the clinical and biological characteristics of pregnancies affected by severe early onset fetal growth restriction.

    PubMed

    Spencer, Rebecca; Ambler, Gareth; Brodszki, Jana; Diemert, Anke; Figueras, Francesc; Gratacós, Eduard; Hansson, Stefan R; Hecher, Kurt; Huertas-Ceballos, Angela; Marlow, Neil; Marsál, Karel; Morsing, Eva; Peebles, Donald; Rossi, Carlo; Sebire, Neil J; Timms, John F; David, Anna L

    2017-01-23

    Fetal growth restriction (FGR) is a serious obstetric condition for which there is currently no treatment. The EVERREST Prospective Study has been designed to characterise the natural history of pregnancies affected by severe early onset FGR and establish a well phenotyped bio-bank. The findings will provide up-to-date information for clinicians and patients and inform the design and conduct of the EVERREST Clinical Trial: a phase I/IIa trial to assess the safety and efficacy of maternal vascular endothelial growth factor (VEGF) gene therapy in severe early onset FGR. Data and samples from the EVERREST Prospective Study will be used to identify ultrasound and/or biochemical markers of prognosis in pregnancies with an estimated fetal weight (EFW) <3rd centile between 20+0 and 26+6 weeks of gestation. This is a 6 year European multicentre prospective cohort study, recruiting women with a singleton pregnancy where the EFW is <3rd centile for gestational age and <600 g at 20+0 to 26+6 weeks of gestation. Detailed data are collected on: maternal history; antenatal, peripartum, and postnatal maternal complications; health economic impact; psychological impact; neonatal condition, progress and complications; and infant growth and neurodevelopment to 2 years of corrected age in surviving infants. Standardised longitudinal ultrasound measurements are performed, including: fetal biometry; uterine artery, umbilical artery, middle cerebral artery, and ductus venosus Doppler velocimetry; and uterine artery and umbilical vein volume blood flow. Samples of maternal blood and urine, amniotic fluid (if amniocentesis performed), placenta, umbilical cord blood, and placental bed (if caesarean delivery performed) are collected for bio-banking. An initial analysis of maternal blood samples at enrolment is planned to identify biochemical markers that are predictors for fetal or neonatal death. The findings of the EVERREST Prospective Study will support the development of a novel therapy for severe early onset FGR by describing in detail the natural history of the disease and by identifying women whose pregnancies have the poorest outcomes, in whom a therapy might be most advantageous. The findings will also enable better counselling of couples with affected pregnancies, and provide a valuable resource for future research into the causes of FGR. NCT02097667 registered 31 st October 2013.

  1. Gestational age assessment in malaria pregnancy cohorts: a prospective ultrasound demonstration project in Malawi

    PubMed Central

    2013-01-01

    Background Malaria during pregnancy is associated with an increased risk for low birth weight (<2500 grams). Distinguishing infants that are born premature (< 37 weeks) from those that are growth-restricted (less than the 10th percentile at birth) requires accurate assessment of gestational age. Where ultrasound is accessible, sonographic confirmation of gestational age is more accurate than menstrual dating. The goal was to pilot the feasibility and utility of adding ultrasound to an observational pregnancy malaria cohort. Methods In July 2009, research staff (three mid-level clinical providers, one nurse) from The Blantyre Malaria Project underwent an intensive one-week ultrasound training to perform foetal biometry. Following an additional four months of practice and remote image review, subjects from an ongoing cohort were recruited for ultrasound to determine gestational age. Gestational age at delivery established by ultrasound was compared with postnatal gestational age assessment (Ballard examination). Results One hundred and seventy-eight women were enrolled. The majority of images were of good quality (94.3%, 509/540) although a learning curve was apparent with 17.5% (24/135) images of unacceptable quality in the first 25% of scans. Ultrasound was used to date 13% of the pregnancies when menstrual dates were unknown and changed the estimated gestational age for an additional 25%. There was poor agreement between the gestational age at delivery as established by the ultrasound protocol compared to that determined by the Ballard examination (bias 0.8 weeks, limits of agreement -3.5 weeks to 5.1 weeks). The distribution of gestational ages by Ballard suggested a clustering of gestational age around the mean with 87% of the values falling between 39 and 41 weeks. The distribution of gestational age by ultrasound confirmed menstrual dates was more typical. Using ultrasound confirmed dates as the gold standard, 78.5% of preterm infants were misclassified as term and 26.8% of small-for gestational age infants misclassified as appropriately grown by Ballard. Conclusion Ultrasound should be strongly considered in prospective malaria studies with obstetric endpoints to confirm gestational age and avoid misclassification of infants as premature or growth-restricted. The use of ultrasound does require a significant investment of time to maintain quality image acquisition. PMID:23734718

  2. Visual impairment and spectacle use in schoolchildren in rural and urban regions in Beijing.

    PubMed

    Guo, Yin; Liu, Li Juan; Xu, Liang; Lv, Yan Yun; Tang, Ping; Feng, Yi; Meng, Lei; Jonas, Jost B

    2014-01-01

    To determine prevalence and associations of visual impairment and frequency of spectacle use among grade 1 and grade 4 students in Beijing. This school-based, cross-sectional study included 382 grade 1 children (age 6.3 ± 0.5 years) and 299 grade 4 children (age 9.4 ± 0.7 years) who underwent a comprehensive eye examination including visual acuity, noncycloplegic refractometry, and ocular biometry. Presenting visual acuity (mean 0.04 ± 0.17 logMAR) was associated with younger age (p = 0.002), hyperopic refractive error (p<0.001), and male sex (p = 0.03). Presenting visual impairment (presenting visual acuity ≤20/40 in the better eye) was found in 44 children (prevalence 6.64 ± 1.0% [95% confidence interval (CI) 4.74, 8.54]). Mean best-corrected visual acuity (right eyes -0.02 ± 0.04 logMAR) was associated with more hyperopic refractive error (p = 0.03) and rural region of habitation (p<0.001). The prevalence of best-corrected visual impairment (best-corrected visual acuity ≤20/40 in the better eye) was 2/652 (0.30 ± 0.21% [95% CI 0.00, 0.72]). Undercorrection of refractive error was present in 53 children (7.99 ± 1.05%) and was associated with older age (p = 0.003; B 0.53; OR 1.71 [95% CI 1.20, 2.42]), myopic refractive error (p = 0.001; B -0.72; OR 0.49 [95% CI 0.35, 0.68]), and longer axial length (p = 0.002; B 0.74; OR 2.10 [95% CI 1.32, 3.32]). Spectacle use was reported for 54 children (8.14 ± 1.06%). Mean refractive error of the worse eyes of these children was -2.09 ± 2.88 D (range -7.38 to +7.25 D). Factors associated with presenting visual impairment were older age, myopic refractive error, and higher maternal education level. Despite a prevalence of myopia of 33% in young schoolchildren in Greater Beijing, prevalence of best-corrected visual impairment (0.30% ± 0.21%), presenting visual impairment (6.64% ± 1.0%), and undercorrection of refractive error (7.99% ± 1.05%) were relatively low.

  3. Comparison of the new biometer OA-1000 with IOLMaster and Tomey AL-3000.

    PubMed

    Goebels, Susanne Christiane; Seitz, Berthold; Langenbucher, Achim

    2013-09-01

    The OA-1000 (Tomey, Japan) is a new optical biometer, which allows measurements of axial length (AL), anterior chamber depth (ACD) and corneal thickness (CT) due to partial coherence interferometry (PCI) technology. The aim of this study was to compare the OA-1000 results with those obtained with the IOLMaster and contact applanation A-scan ultrasonography. We examined 133 eyes of 75 patients with age related cataract. Mean age was 72.0 ± 9.5 years. Biometry measurements of AL and ACD were performed with the Tomey OA-1000 based on PCI, the IOLMaster based on PCI (AL) and slit projection (ACD), and the Tomey AL-3000 based on contact applanation A-scan ultrasonography. Mean AL using the IOLMaster was 23.21 ± 1.08 mm, using the AL-3000 was 22.79 ± 1.04 mm, using the OA-1000 it was 22.97 ± 1.1 mm. Mean ACD using the IOLMaster was 2.99 ± 0.41 mm, using the OA-1000 3.40 ± 0.46 mm, using the Tomey AL-3000 it was 2.93 ± 0.43 mm. Mean difference between the AL and ACD measured with the OA-1000 and the IOLMaster was 0.22 ± 0.047 mm and 0.40 ± 0.33 mm, between OA-1000 and the AL-3000 it was 0.19 ± 0.23 mm and 0.47 ± 0.33 mm, and between IOLMaster and AL-3000 it was 0.42 ± 0.23 and 0.09 ± 0.36 mm. For AL the correlation coefficient R between IOLMaster and OA-1000 was 0.999, between IOLMaster and AL-3000 it was 0.976, between AL-3000 and OA-1000 it was 0.977. For ACD R between IOLMaster and OA-1000 was 0.735, between IOLMaster and AL-3000 it was 0.822, between AL-3000 and OA-1000 it was 0.716 (all p < 0.001). Compared with other used clinical instruments the OA-1000 generates accurate results. Although differences were found, the OA-1000 provided results that correlated well with the values of IOLMaster and AL-3000.

  4. Comparison of refractive development and retinal dopamine in OFF pathway mutant and C57BL/6J wild-type mice

    PubMed Central

    Chakraborty, Ranjay; Park, Han na; Aung, Moe H.; Tan, Christopher C.; Sidhu, Curran S.; Iuvone, P. Michael

    2014-01-01

    Purpose Proper visual transmission depends on the retinal ON and OFF pathways. We used Vsx1−/− mice with a retinal OFF visual pathway defect to determine the role of OFF pathway signaling in refractive development (RD) of the eye. Methods Refractive development was measured every 2 weeks in Vsx1−/−, Vsx1+/+ (both on 129S1/Sv background), and commonly used C57BL/6J mice from 4 to 12 weeks of age. Form deprivation (FD) was induced monocularly from 4 weeks of age using head-mounted diffuser goggles. Refractive state, corneal curvature, and ocular biometry were obtained weekly using photorefraction, keratometry, and 1310 nm spectral-domain optical coherence tomography. Retinal dopamine and its metabolite, 3,4-dihydroxyphenylacetate (DOPAC), were measured using high-performance liquid chromatography (HPLC). Results During normal development, the Vsx1−/− and Vsx1+/+ mice showed similar myopic refractions at younger ages (4 weeks, Vsx1−/−: −5.28±0.75 diopter (D); WT: −4.73±0.98 D) and became significantly hyperopic by 12 weeks of age (Vsx1−/−: 3.28±0.82 D; WT: 5.33±0.81 D). However, the C57BL/6J mice were relatively hyperopic at younger ages (mean refraction at 4 weeks, 3.40±0.43 D), and developed more hyperopic refractions until about 7 weeks of age (8.07±0.55 D) before stabilizing. Eight weeks of FD did not induce a myopic shift in the 129S1/Sv animals (0.16±0.85 D), as opposed to a significant shift of −4.29±0.42 D in the C57BL/6J mice. At 4 weeks of visual development, dopamine turnover (the DOPAC/dopamine ratio) was significantly greater in the 129S1/Sv mice compared to the C57BL/6J mice. FD did not alter the levels of dopamine between the goggled and opposite eyes for any genotype or strain. Conclusions OFF pathway signaling may not be critically important for normal refractive development in mice. Elevated retinal dopamine turnover in early refractive development may prevent FD myopia in 129S1/Sv mice compared to C57BL/6J mice. PMID:25352740

  5. ASAS Centennial Paper: Animal breeding research and the Journal of Animal Science: A century of co-evolution.

    PubMed

    Hohenboken, W D

    2009-01-01

    Animal breeding reports in the Journal of Animal Science (JAS) and in its predecessor, Proceedings of the American Society of Animal Production, were counted and categorized. In 22 volumes of the Proceedings of the American Society of Animal Production, 155 articles had animal breeding content, of which 54% were research reports, 17% extension communications, and 28% syntheses or reviews. Several of the latter featured advice from the livestock industry to the scientific community. Thirty-one percent of articles concerned swine, whereas beef cattle, dairy cattle, and sheep each accounted for an additional 20%. In the 67 yr of JAS publication, 3,045 research papers were identified with animal breeding content, nearly half of them published since 1990. Growth in publication output was modest during the 1950s, robust in the 1960s through 1980s, moderate in the 1990s, and static in the 2000s. Important topics included genetic resource evaluation (a subject in 55% of all manuscripts), genetic parameter estimation, selection programs, and nonrandom mating systems. Maternal effects and genotype x environment interactions were featured in 17 and 15% of all manuscripts, respectively, whereas 6% dealt with a simply inherited trait. Only 4% of manuscripts included economic analysis of a breeding program or intervention. Interest in molecular biology and biometry has surged in the 1990s and 2000s. Approximately 50% of all papers involved cattle, a fifth of which concerned dairy cattle or beef x dairy crossbreds. A quarter of papers concerned swine, 15% concerned sheep, and 3% considered laboratory rodents, with the proportional contribution of sheep research decreasing across time. Authors from the Midwestern and Southern sections of the American Society of Animal Science had greater proportional contributions than Western and Northeastern section authors, and contributions of university and state experiment station authors outnumbered those of USDA-ARS authors. The proportional contribution of international authors increased across time, reaching 45% for the 2000s, as that of university and experiment station authors decreased and that of USDA-ARS authors remained fairly constant. Subjective analysis suggested substantial levels of creativity, innovation, and cooperation in JAS animal breeding research, a strong international perspective, but also a marked degree of imitation and repetition in subject matter content.

  6. Compensation of corneal oblique astigmatism by internal optics: a theoretical analysis.

    PubMed

    Liu, Tao; Thibos, Larry N

    2017-05-01

    Oblique astigmatism is a prominent optical aberration of peripheral vision caused by oblique incidence of rays striking the refracting surfaces of the cornea and crystalline lens. We inquired whether oblique astigmatism from these two sources should be expected, theoretically, to have the same or opposite signs across the visual field at various states of accommodation. Oblique astigmatism was computed across the central visual field for a rotationally-symmetric schematic-eye using optical design software. Accommodative state was varied by altering the apical radius of curvature and separation of the biconvex lens's two aspheric surfaces in a manner consistent with published biometry. Oblique astigmatism was evaluated separately for the whole eye, the cornea, and the isolated lens over a wide range of surface curvatures and asphericity values associated with the accommodating lens. We also computed internal oblique astigmatism by subtracting corneal oblique astigmatism from whole-eye oblique astigmatism. A visual field map of oblique astigmatism for the cornea in the Navarro model follows the classic, textbook description of radially-oriented axes everywhere in the field. Despite large changes in surface properties during accommodation, intrinsic astigmatism of the isolated human lens for collimated light is also radially oriented and nearly independent of accommodation both in theory and in real eyes. However, the magnitude of ocular oblique astigmatism is smaller than that of the cornea alone, indicating partial compensation by the internal optics. This implies internal oblique astigmatism (which includes wavefront propagation from the posterior surface of the cornea to the anterior surface of the lens and intrinsic lens astigmatism) must have tangentially-oriented axes. This non-classical pattern of tangential axes for internal astigmatism was traced to the influence of corneal power on the angles of incidence of rays striking the internal lens. Partial compensation of corneal astigmatism by internal optics is due mainly to the highly converging nature of wavefronts incident upon the lens resulting from corneal refraction. The degree of compensation is quadratically dependent on eccentricity but is expected to diminish as the eye accommodates. Neutralising the cornea by index-matching defeats internal compensation, revealing classical, radially-oriented oblique astigmatism in the isolated lens. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  7. [Clinical experiences after implantation of various lens types in silicon oil tamponade].

    PubMed

    Effert, R; Lommatzsch, A; Wessing, A

    1996-06-01

    A tamponade of the vitreous space with silicone oil will obligatory lead to cataract after 6 to 12 months. Today it is easily possible, to implant an artificial lense in silicone oil filled eyes. However the combination of an artificial lense and silicone oil will lead to a strong inflammation in the anterior segment of the eye. 22 pseudophacic patients with silicone oil tamponade were examined 2 to 6 months after the operation. In 12 patients simple artificial lenses were implanted, in 10 patients heparin modified lenses were implanted. In 10 cases the lens was implanted followed by the insufflation of silicone oil in the vitreous cavity, in 2 cases a lens was implanted in a silicone oil filled eye and the silicon oil was not removed. In 8 cases the implantation of the artificial lens has been performed some months to years before the insufflation of the silicone oil. The indication for the silicon oil tamponade was a PVR retinal detachment in all cases. The following parameters were examined: Reaction of the pupil to light, pupil round or oval in miosis, examination of the fundus peripherie possible after mydriasis, fixation of the iris with parts of the capsula or with the anterior surface of the lens? In addition in 12 cases the postoperative refraction was compared with the results of the biometry, which was performed before the operation. In the cases with a simple lens in about 50% an incomplete miosis or an oval pupil because of fixation of the iris with parts of the capsula or with the anterior surface of the lense could be observed. In the cases with heparin modified lenses these complications could be observed in 20%. In all cases a strong opacification of the capsula was seen. In 8 of 12 cases with combined procedure a small hyperopia was measured, in 4 cases a large deviation was measured. The implantation of an artificial lens in silicone oil filled eyes is an alternative to the aphacic status with an Ando Iridectomy. Obviously heparin modified lenses have advantages in these cases. Because of the strong cataract formation we suggest to remove the anterior and the posterior capsula in the first operative session and to implant the haptics of the lens into the sulcus. Because of the high rate of complications generally first a stable retina condition should be reached before the implanation of an artificial lens is performed.

  8. Associations between neural injury markers of intrauterine growth-restricted infants and neurodevelopment at 2 years of age.

    PubMed

    Mazarico, E; Llurba, E; Cabero, L; Sánchez, O; Valls, A; Martín-Ancel, A; Cardenas, D; Gómez Roig, M D

    2018-04-18

    The aim of this study was to evaluate the relationships between brain injury biomarkers in intrauterine growth-restricted (IUGR) infants (S100B and neuron-specific enolase (NSE)) and neurodevelopment at 2 years of age. This prospective case-control study was a cooperative effort among Spanish Maternal and Child Health Network (Retic SAMID) hospitals. At inclusion, biometry for estimated fetal weight and feto-placental Doppler variables were measured for each infant. Maternal venous blood and fetal umbilical arterial blood samples were collected at the time of delivery and neural injury markers S100B and NSE concentrations were measured. Neurodevelopment was evaluated at 2 years of age using the Bayley Scales of Infant and Toddler Development, third edition (Bayley-III). Fifty six pregnancies were included. Thirty-one infants were classified as IUGR and 25 as non-IUGR. Neurodevelopmental evaluation at 2 years of age indicated that there were no between-group differences for any of the tests. For all patients in both groups, we found statistically significant inverse relationships between the concentrations of NSE in the cord blood and the results of the cognitive test (r = -271, p = .042), fine motor subtest (r = -280, p = .036), and social-emotional test (r = -349, p = .015). We also found statistically significant differences between the concentrations of S100B in the cord blood and the results of the cognitive test (r = -306, p = .022) and expressive communication subtest (r = -304, p = .023). For the IUGR group, we found a significant inverse relationship between the concentrations of S100B in the maternal serum and the results of adaptive behavior test (p < .05). In the non-IUGR group, we found statistically significant inverse relationships between the concentration of NSE in the cord blood and the results of the fine motor subtest (r = -446, p = .025) and social-emotional test (r = -489, p = .021). The difference between the concentration of S100B in the cord blood and the language composite score was also statistically significant (p = .038). At 2 years of age, the concentrations of NSE and S100B were higher in the non-IUGR and IUGR groups with the worst scores for some areas of neurodevelopmental evaluation. The value of these biomarkers for prognostic neurodevelopmental use requires further investigation for both non-IUGR and IUGR infants.

  9. Visual and Refractive Outcomes in Manual versus Femtosecond Laser-Assisted Cataract Surgery: A Single-Center Retrospective Cohort Analysis of 1838 Eyes.

    PubMed

    Berk, Thomas A; Schlenker, Matthew B; Campos-Möller, Xavier; Pereira, Austin M; Ahmed, Iqbal Ike K

    2018-03-06

    Femtosecond laser-assisted cataract surgery (FLACS) has emerged as an alternative to manual cataract surgery (MCS) for corneal incision and capsulorhexis creation, as well as nuclear fragmentation. This study compares postoperative refractive and visual outcomes in eyes receiving MCS or FLACS. Single-center, comparative, retrospective cohort analysis. Consecutive eyes receiving FLACS and MCS from July 1, 2012, to July 31, 2015, at a single tertiary care center. Demographic data, ocular history, preoperative measurements and biometry, and postoperative surgical results were retrospectively obtained and statistically analyzed using a generalized linear mixed model adjusting for differences in baseline characteristics and within-patient correlation. A 2-tailed P value <0.05 was considered statistically significant throughout the study. Percentage of eyes achieving absolute error (AE) ≤0.5 diopters (D). Secondary outcomes included percentage of eyes with AE ≤0.25 D and ≤1.0 D, and percentage of distance-targeted eyes achieving uncorrected distance visual acuity (UDVA) of 20/20 or better, 20/25 or better, and 20/30 or better. A total of 883 eyes received MCS and 955 received FLACS among 1089 patients. Some 82.6% of FLACS eyes and 78.8% of MCS eyes had ≤0.5 D of AE at 3 weeks, representing an adjusted odds ratio (OR) of 1.28 (95% confidence interval [CI], 0.98-1.66) of FLACS relative to MCS being within target. Some 97.1% of FLACS and 97.2% of MCS eyes had ≤1.0 D of AE (OR, 0.96; 95% CI, 0.57-1.60) and 49.3% of FLACS and 46.3% of MCS eyes, ≤0.25 D of AE (OR, 1.13; 95% CI, 0.91-1.39). Factors predictive of a favorable refractive outcome included axial length between 22 and 24.8 mm, receiving a toric intraocular lens, less preoperative cylinder, and greater preoperative average keratometry. There was no significant difference in the percentage of patients targeted for distance who achieved UDVA of 20/20 or better (P = 0.30), 20/25 or better (P = 0.06), or 20/30 or better (P = 0.66) vision. Postoperatively, there was no statistically significant difference found between eyes undergoing FLACS and eyes undergoing MCS with respect to refractive and visual outcomes. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. N‐Acetylcysteine, a glutathione precursor, reverts vascular dysfunction and endothelial epigenetic programming in intrauterine growth restricted guinea pigs

    PubMed Central

    Herrera, Emilio A.; Cifuentes‐Zúñiga, Francisca; Figueroa, Esteban; Villanueva, Cristian; Hernández, Cherie; Alegría, René; Arroyo‐Jousse, Viviana; Peñaloza, Estefania; Farías, Marcelo; Uauy, Ricardo; Casanello, Paola

    2016-01-01

    Key points Intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial epigenetic programming of the umbilical vessels.There is no evidence that this epigenetic programming is occurring on systemic fetal arteries.In IUGR guinea pigs we studied the functional and epigenetic programming of endothelial nitric oxide synthase (eNOS) (Nos3 gene) in umbilical and systemic fetal arteries, addressing the role of oxidative stress in this process by maternal treatment with N‐acetylcysteine (NAC) during the second half of gestation.The present study suggests that IUGR endothelial cells have common molecular markers of programming in umbilical and systemic arteries. Notably, maternal treatment with NAC restores fetal growth by increasing placental efficiency and reverting the functional and epigenetic programming of eNOS in arterial endothelium in IUGR guinea pigs. Abstract In humans, intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial programming in umbilical vessels. We aimed to determine the effects of maternal antioxidant treatment with N‐acetylcysteine (NAC) on fetal endothelial function and endothelial nitric oxide synthase (eNOS) programming in IUGR guinea pigs. IUGR was induced by implanting ameroid constrictors on uterine arteries of pregnant guinea pigs at mid gestation, half of the sows receiving NAC in the drinking water (from day 34 until term). Fetal biometry and placental vascular resistance were followed by ultrasound throughout gestation. At term, umbilical arteries and fetal aortae were isolated to assess endothelial function by wire‐myography. Primary cultures of endothelial cells (ECs) from fetal aorta, femoral and umbilical arteries were used to determine eNOS mRNA levels by quantitative PCR and analyse DNA methylation in the Nos3 promoter by pyrosequencing. Doppler ultrasound measurements showed that NAC reduced placental vascular resistance in IUGR (P < 0.05) and recovered fetal weight (P < 0.05), increasing fetal‐to‐placental ratio at term (∼40%) (P < 0.001). In IUGR, NAC treatment restored eNOS‐dependent relaxation in aorta and umbilical arteries (P < 0.05), normalizing eNOS mRNA levels in EC fetal and umbilical arteries (P < 0.05). IUGR‐derived ECs had a decreased DNA methylation (∼30%) at CpG −170 (from the transcription start site) and this epigenetic signature was absent in NAC‐treated fetuses (P < 0.001). These data show that IUGR‐ECs have common molecular markers of eNOS programming in umbilical and systemic arteries and this effect is prevented by maternal treatment with antioxidants. PMID:27739590

  11. The ecology and evolutionary endocrinology of reproduction in the human female.

    PubMed

    Vitzthum, Virginia J

    2009-01-01

    Human reproductive ecology (HRE) is the study of the mechanisms that link variation in reproductive traits with variation in local habitats. Empirical and theoretical contributions from biological anthropology, physiology, and demography have established the foundation necessary for developing a comprehensive understanding, grounded in life history theory (LHT), of temporal, individual, and populational variation in women's reproductive functioning. LHT posits that natural selection leads to the evolution of mechanisms that tend to allocate resources to the competing demands of growth, reproduction, and survival such that fitness is locally maximized. (That is, among alternative allocation patterns exhibited in a population, those having the highest inclusive fitness will become more common over generational time.) Hence, strategic modulation of reproductive effort is potentially adaptive because investment in a new conception may risk one's own survival, future reproductive opportunities, and/or current offspring survival. The hypothalamic-pituitary-ovarian (HPO) axis is the principal neuroendocrine pathway by which the human female modulates reproductive functioning according to the changing conditions in her habitat. Adjustments of reproductive investment in a potential conception are manifested in temporal and individual variation in ovarian cycle length, ovulation, hormone levels, and the probability of conception. Understanding the extent and causes of adaptive and non-adaptive variation in ovarian functioning is fundamental to ascertaining the proximate and remote determinants of human reproductive patterns. In this review I consider what is known and what still needs to be learned of the ecology of women's reproductive biology, beginning with a discussion of the principal explanatory frameworks in HRE and the biometry of ovarian functioning. Turning next to empirical studies, it is evident that marked variation between cycles, women, and populations is the norm rather than an aberration. Other than woman's age, the determinants of these differences are not well characterized, although developmental conditions, dietary practices, genetic variation, and epigenetic mechanisms have all been hypothesized to play some role. It is also evident that the reproductive functioning of women born and living in arduous conditions is not analogous to that of athletes, dieters, or even the lower end of the "normal range" of HPO functioning in wealthier populations. Contrary to the presumption that humans have low fecundity and an inefficient reproductive system, both theory and present evidence suggest that we may actually have very high fecundity and a reproductive system that has evolved to be flexible, ruthlessly efficient and, most importantly, strategic. Copyright 2009 Wiley-Liss, Inc.

  12. Teaching Soil Science in Primary and Secondary Schools

    NASA Technical Reports Server (NTRS)

    Levine, Elissa R.

    1998-01-01

    Earth's thin layer of soil is a fragile resource, made up of minerals, organic materials, air, water, and billions of living organisms. Soils plays a variety of critical roles that sustain life on Earth. If we think about soil, we tend to see it first as the source of most of the food we eat and the fibers we use, such as wood and cotton. Few students realize that soils also provide the key ingredients to many of the medicines (including antibiotics), cosmetics, and dyes that we use. Fewer still understand the importance of soils in integrating, controlling, and regulating the movement of air, water, materials, and energy between the hydrosphere, lithosphere, atmosphere, and biosphere. Because soil sustains life, it offers both a context and a natural laboratory for investigating these interactions. The enclosed poster, which integrates soil profiles with typical landscapes in which soils form, can also help students explore the interrelationships of Earth systems and gain an understanding of our soil resources. The poster, produced jointly by the American Geological Institute and the Soil Science Society of America, aims to increase awareness of the importance of soil, as does the GLOBE (Global Learning and Observations To Benefit the Environment) Program. Vice President Al Gore instituted the GLOBE Program on Earth Day of 1993 to increase environmental awareness of individuals throughout the world, contribute to a better scientific understanding of the Earth, and help all students reach higher levels of achievement in science and mathematics. GLOBE functions as a partnership between scientists, students, and teachers in which scientists design protocols for specific measurements they need for their research that can be performed by K-12 students. Teachers are trained in the GLOBE protocols and teach them to their students. Students make the measurements, enter data via the Internet to a central data archive, and the data becomes available to scientists and the general community. Students benefit by having a "hands-on"experience in science, math, and technology, using their local environment as a learning laboratory, as well as contact with scientists and other students around the world. Soil investigations have become an essential component of GLOBE. The protocols that have been developed so far within the GLOBE program include GPS Location, Atmosphere/Climate, Soil Characterization, Soil Moisture and Temperature, Land Cover/Biometry, Hydrology, and Satellite Image Classification. For the GLOBE Soil Characterization Protocol, students explore the physical. chemical, and morphological properties of the soil at their study site. They are asked to dig a pit or use an auger to about 1 meter at at least 2 sites.

  13. Age-related effects on leaf area/sapwood area relationships, canopy transpiration and carbon gain of Norway spruce stands (Picea abies) in the Fichtelgebirge, Germany.

    PubMed

    Köstner, B; Falge, E; Tenhunen, J D

    2002-06-01

    Stand age is an important structural determinant of canopy transpiration (E(c)) and carbon gain. Another more functional parameter of forest structure is the leaf area/sapwood area relationship, A(L)/A(S), which changes with site conditions and has been used to estimate leaf area index of forest canopies. The interpretation of age-related changes in A(L)/A(S) and the question of how A(L)/A(S) is related to forest functions are of current interest because they may help to explain forest canopy fluxes and growth. We conducted studies in mature stands of Picea abies (L.) Karst. varying in age from 40 to 140 years, in tree density from 1680 to 320 trees ha(-1), and in tree height from 15 to 30 m. Structural parameters were measured by biomass harvests of individual trees and stand biometry. We estimated E(c) from scaled-up xylem sap flux of trees, and canopy-level fluxes were predicted by a three-dimensional microclimate and gas exchange model (STANDFLUX). In contrast to pine species, A(L)/A(S) of P. abies increased with stand age from 0.26 to 0.48 m(2) cm(-2). Agreement between E(c) derived from scaled-up sap flux and modeled canopy transpiration was obtained with the same parameterization of needle physiology independent of stand age. Reduced light interception per leaf area and, as a consequence, reductions in net canopy photosynthesis (A(c)), canopy conductance (g(c)) and E(c) were predicted by the model in the older stands. Seasonal water-use efficiency (WUE = A(c)/E(c)), derived from scaled-up sap flux and stem growth as well as from model simulation, declined with increasing A(L)/A(S) and stand age. Based on the different behavior of age-related A(L)/A(S) in Norway spruce stands compared with other tree species, we conclude that WUE rather than A(L)/A(S) could represent a common age-related property of all species. We also conclude that, in addition to hydraulic limitations reducing carbon gain in old stands, a functional change in A(L)/A(S) that is related to reduced light interception per leaf area provides another potential explanation for reduced carbon gain in old stands of P. abies, even when hydraulic constraints increase in response to changes in canopy architecture and aging.

  14. A Population-based survey of the prevalence and types of glaucoma in Nigeria: results from the Nigeria National Blindness and Visual Impairment Survey.

    PubMed

    Kyari, Fatima; Entekume, Gabriel; Rabiu, Mansur; Spry, Paul; Wormald, Richard; Nolan, Winifred; Murthy, Gudlavalleti V S; Gilbert, Clare E

    2015-12-12

    Glaucoma is the leading cause of irreversible blindness worldwide. There tends to be a lower reporting of glaucoma in Africa compared to other blinding conditions in global burden data. Research findings of glaucoma in Nigeria will significantly increase our understanding of glaucoma in Nigeria, in people of the West African diaspora and similar population groups. We determined the prevalence and types of glaucoma in Nigeria from the Nigeria National Blindness and Visual Impairment cross-sectional Survey of adults aged ≥40 years. Multistage stratified cluster random sampling with probability-proportional-to-size procedures were used to select a nationally representative sample of 15,027 persons aged ≥40 years. Participants had logMAR visual acuity measurement, FDT visual function testing, autorefraction, A-scan biometry and optic disc assessment. Participants with visual acuity of worse than 6/12 or suspicious optic discs had detailed examination including Goldmann applanation tonometry, gonioscopy and fundus photography. Disc images were graded by Moorfields Eye Hospital Reading Centre. Glaucoma was defined using International Society of Geographical and Epidemiological Ophthalmology criteria; and classified into primary open-angle or primary angle-closure or secondary glaucoma. Diagnosis of glaucoma was based on ISGEO classification. The type of glaucoma was determined by gonioscopy. A total of 13,591 participants in 305 clusters were examined (response rate 90.4 %). Optic disc grading was available for 25,289 (93 %) eyes of 13,081 (96 %) participants. There were 682 participants with glaucoma; a prevalence of 5.02 % (95 % CI 4.60-5.47). Among those with definite primary glaucoma that had gonioscopy (n = 243), open-angle glaucoma was more common (86 %) than angle-closure glaucoma (14 %). 8 % of glaucoma was secondary with the commonest causes being couching (38 %), trauma (21 %) and uveitis (19 %). Only 5.6 % (38/682) of participants with glaucoma knew they had the condition. One in every 5 persons with glaucoma (136;20 %) was blind i.e., visual acuity worse than 3/60. Nigeria has a high prevalence of glaucoma which is largely open-angle glaucoma. A high proportion of those affected are blind. Secondary glaucoma was mostly as a consequence of procedures for cataract. Public health control strategies and high quality glaucoma care service will be required to reduce morbidity and blindness from glaucoma.

  15. Diffusion-weighted magnetic resonance imaging of the fetal brain in intrauterine growth restriction.

    PubMed

    Arthurs, O J; Rega, A; Guimiot, F; Belarbi, N; Rosenblatt, J; Biran, V; Elmaleh, M; Sebag, G; Alison, M

    2017-07-01

    Diffusion-weighted magnetic resonance imaging (DWI) is a sensitive method for assessing brain maturation and detecting brain lesions, providing apparent diffusion coefficient (ADC) values as a measure of water diffusion. Abnormal ADC values are seen in ischemic brain lesions, such as those associated with acute or chronic hypoxia. The aim of this study was to assess whether ADC values in the fetal brain were different in fetuses with severe intrauterine growth restriction (IUGR) compared with normal controls. Brain magnetic resonance imaging (MRI) with single-shot axial DWI (b = 0 and b = 700 s/mm 2 ) was performed in 30 fetuses with severe IUGR (estimated fetal weight < 3 rd centile with absent or reversed umbilical artery Doppler flow) and in 24 normal controls of similar gestational age. Brain morphology and biometry were analyzed. ADC values were measured in frontal and occipital white matter, centrum semiovale, thalami, cerebellar hemisphere and pons. Frontal-occipital and frontal-cerebellar ADC ratios were calculated, and values were compared between IUGR fetuses and controls. There was no difference in gestational age at MRI between IUGR and control fetuses (IUGR, 30.2 ± 1.6 weeks vs controls, 30.7 ± 1.4 weeks). Fetal brain morphology and signals were normal in all fetuses. Brain dimensions (supratentorial ± infratentorial) were decreased (Z-score, < -2) in 20 (66.7%) IUGR fetuses. Compared with controls, IUGR fetuses had significantly lower ADC values in frontal white matter (1.97 ± 0.23 vs 2.17 ± 0.22 × 10 -3 mm 2 /s; P < 0.0001), thalami (1.04 ± 0.15 vs 1.13 ± 0.10 ×10 -3 mm 2 /s; P = 0.0002), centrum semiovale (1.86 ± 0.22 vs 1.97 ± 0.23 ×10 -3 mm 2 /s; P = 0.01) and pons (0.85 ± 0.19 vs 0.94 ± 0.12 ×10 -3 mm 2 /s; P = 0.043). IUGR fetuses had a lower frontal-occipital ADC ratio than did normal fetuses (1.00 ± 0.11 vs 1.08 ± 0.05; P = 0.003). ADC values in IUGR fetuses were significantly lower than in normal controls in the frontal white matter, thalami, centrum semiovale and pons, suggesting abnormal maturation in these regions. However, the prognostic value of these ADC changes is still unknown. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  16. Prediction of small-for-gestational-age neonate by third-trimester fetal biometry and impact of ultrasound-delivery interval.

    PubMed

    Reboul, Q; Delabaere, A; Luo, Z C; Nuyt, A-M; Wu, Y; Chauleur, C; Fraser, W; Audibert, F

    2017-03-01

    To compare third-trimester ultrasound screening methods to predict small-for-gestational age (SGA), and to evaluate the impact of the ultrasound-delivery interval on screening performance. In this prospective study, data were collected from a multicenter singleton cohort study investigating the links between various exposures during pregnancy with birth outcome and later health in children. We included women, recruited in the first trimester, who had complete outcome data and had undergone third-trimester ultrasound examination. Demographic, clinical and biological variables were also collected from both parents. We compared prediction of delivery of a SGA neonate (birth weight < 10 th percentile) by the following methods: abdominal circumference (AC) Z-score based on Hadlock curves (Hadlock AC), on INTERGROWTH-21 st Project curves (Intergrowth AC) and on Salomon curves (Salomon AC); estimated fetal weight (EFW) Z-score based on Hadlock curves (Hadlock EFW) and on customized curves from Gardosi (Gardosi EFW); and fetal growth velocity based on change in AC between second and third trimesters (FGVAC). We also assessed the following ultrasound-delivery intervals: ≤ 4 weeks, ≤ 6 weeks and ≤ 10 weeks. Third-trimester ultrasound was performed in 1805 patients with complete outcome data, of whom 158 (8.8%) delivered a SGA neonate. Ultrasound examination was at a median gestational age of 32 (interquartile range, 31-33) weeks. The ultrasound-delivery interval was ≤ 4 weeks in 17.2% of cases, ≤ 6 weeks in 48.1% of cases and ≤ 10 weeks in 97.3% of cases. Areas under the receiver-operating characteristics curve (AUC) were 0.772 for Salomon AC, 0.768 for Hadlock EFW, 0.766 for Hadlock AC, 0.765 for Intergrowth AC, 0.708 for Gardosi EFW and 0.674 for FGVAC (all P < 0.0001). The screening method with the highest AUC for an ultrasound-delivery interval ≤ 4 weeks was Salomon AC (AUC, 0.856), ≤ 6 weeks was Hadlock AC (AUC, 0.824) and ≤ 10 weeks was Salomon AC (AUC, 0.780). At a fixed 10% false-positive rate, the best detection rates were 60.0%, 54.1% and 42.1% for intervals ≤ 4, ≤ 6 and ≤ 10 weeks, respectively. Third-trimester ultrasound measurements provide poor to moderate prediction of SGA. A shorter ultrasound-delivery interval provides better prediction than does a longer interval. Further studies are needed to test the effect of including maternal or biological characteristics in SGA screening. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  17. Increasing trend of illicit drug abuse in Thai parturient at Siriraj Hospital.

    PubMed

    Inthawiwat, Suchada; Rattanachaiyanont, Manee; Leerasiri, Pichai; Manoch, Darapa; Titapant, Vitaya

    2002-10-01

    To report the magnitude of the problem and to evaluate the outcome of maternal illicit drug use in Thai parturients. Retrospective case-control study. Department of Obstetrics and Gynecology, Faculty of Medicine Siriraj Hospital, Mahidol University. The subjects were 44,640 parturients who had deliveries at Siriraj Hospital from January 1998 to December 2001 and were divided into two groups. The study group consisted of 66 parturients with a history of illicit drug use and the control group consisted of 44,574 parturients without a history of illicit drug use. Medical records of 66 parturients with a history of illicit drug use were reviewed. Obstetric statistics of the department were retrieved from the computerized database in the Division of Obstetric and Gynecologic Registry. The data were analyzed using descriptive statistics. Characteristics of parturients, pregnancy outcome, type and incidence of illicit drug. Within the study period, 66 cases of maternal illicit drug use were identifiable during the intrapartum period; 65 cases used amphetamine or derivatives and 1 case used an opioid derivative. The number had risen from 1 case in 1998 to 58 cases in 2001. Mean age of the patients was 23.30 +/- 6.04 years. Compared to the control group which included 44,574 parturients, the patients had a lower incidence of antenatal care (ANC rate = 21.21% vs 94.35%; RR = 0.23, 95% CI = 0.14-0.26), a higher incidence of HIV infection (10% vs 2%; RR = 6.09, 95% CI = 2.83-13.12), a higher incidence of birth before arrival (BBA rate = 9.09% vs 1.06%; RR = 8.59, 95% CI = 3.98-18.51), and a lower cesarean section rate (10.60% vs 26.36%; RR = 0.40, 95% CI = 0.20-0.81). There were no serious intrapartum, immediate postpartum and neonatal complication. Fetal outcome included a higher incidence of low birth weight infants (22.73% vs 10.23%; RR = 2.22, 95% CI = 1.42-3.46) and a smaller head circumference than the normal range of Thai fetal biometry (31.85 +/- 1.47 cm). There is an increasing trend of illicit drug use in Thai parturients. Although the present case series of drug abuse in Thai parturients cannot give the whole picture of maternal drug abuse in the Thai population, the dramatic increase in the identifiable cases during the past 4 years is very alarming. Currently, the outcome of pregnancy in case detected during intrapartum is not much different from that in the general population. However, there are potential risks for the patients and their babies. All medical staffs should be aware of this condition. Careful clinical data gathering and laboratory testing are suggested for prevention of complications and the potential hazards of this problem.

  18. Outdoor activity and myopia among primary students in rural and urban regions of Beijing.

    PubMed

    Guo, Yin; Liu, Li Juan; Xu, Liang; Lv, Yan Yun; Tang, Ping; Feng, Yi; Meng, Meng; Jonas, Jost B

    2013-02-01

    To assess associations among outdoor activity, ocular biometric parameters, and myopia among grade 1 and grade 4 primary students in Beijing. School-based, cross-sectional study. A total of 382 grade 1 and 299 grade 4 children participated in the study. The children underwent a comprehensive eye examination, including ocular biometry by optical low-coherence reflectometry and noncycloplegic refractometry. Parents and children participated in a detailed interview, including questions on time spent indoors and outdoors. Factors associated with myopia. The study included 681 children, with 382 (56.1%) students from grade 1 (mean age, 6.3 ± 0.5 years; range, 5-8 years) and 299 students from grade 4 (mean age, 9.4 ± 0.7 years; range, 8-13 years); 370 students (54.3%) lived in the urban region. The mean daily time spent outdoors was 1.6 ± 0.8 hours (range, 0.5-5.1 hours). In multivariate analysis, axial length was significantly associated with older age (P<0.001; standardized β coefficient, 0.28), taller body height (P = 0.001; β, 0.18), maternal myopia (P = 0.03; β, 0.09), and urban region of habitation (P<0.001; β, -0.21), or alternatively to the region of habitation, with less time spent outdoors (P = 0.001; β, -0.16) and more time spent indoors studying (P = 0.02; β, 0.10). The axial length-to-corneal curvature radius ratio was associated with older age, urban region of habitation, maternal and paternal myopia, and paternal level of education. Presence of myopia (defined as refractive error ≤-1 diopters in the right eye) was associated with older age (P<0.001; odds ratio [OR], 1.45; 95% confidence interval [CI], 1.24-1.69), maternal myopia (P<0.001; OR, 2.99; 95% CI, 1.94-5.35), and urban region of habitation (P<0.001; OR, 0.17; 95% CI, 0.11-0.26), or alternatively to the region of habitation, with less time spent outdoors (P<0.001; OR, 0.32; 95% CI, 0.21-0.48) and more time spent indoors studying (P<0.001; OR, 1.38; 95% CI, 1.09-1.75). Less outdoor activity, more indoor studying, older age, maternal myopia, and urban region of habitation were associated with longer ocular axial length and myopia in grade 1 and grade 4 primary school children in Greater Beijing. Remaining outdoors more (e.g., during school) may reduce the high prevalence of myopia in the young generation in Beijing. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Astronaut Preflight Cardiovascular Variables Associated with Vascular Compliance are Highly Correlated with Post-Flight Eye Outcome Measures in the Visual Impairment Intracranial Pressure (VIIP) Syndrome Following Long Duration Spaceflight

    NASA Technical Reports Server (NTRS)

    Otto, Christian; Ploutz-Snyder, R.

    2015-01-01

    The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti-lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post-flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio- each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical correlation between the eye outcomes and the twelve astronaut cardiovascular variables available for all 31 subjects. Results: A highly significant canonical correlation was observed among the canonical solutions (p<.00001), with an average best canonical correlation of.97. The results suggest a strong association between astronauts' measures of cardiovascular health and the seven eye outcomes of the VIIP syndrome used in this analysis. Furthermore, the "joint test" revealed a significant difference in cardiovascular profile between male and female astronauts (Prob > F = 0.00001). Overall, female astronauts demonstrated a significantly healthier cardiovascular status. Individually, the female astronauts had significantly healthier profiles on seven of twelve cardiovascular variables than the men (p values ranging from <0.0001 to <0.05). Male astronauts did not demonstrate significantly healthier values on any of the twelve cardiovascular variables measured

  20. N-Acetylcysteine, a glutathione precursor, reverts vascular dysfunction and endothelial epigenetic programming in intrauterine growth restricted guinea pigs.

    PubMed

    Herrera, Emilio A; Cifuentes-Zúñiga, Francisca; Figueroa, Esteban; Villanueva, Cristian; Hernández, Cherie; Alegría, René; Arroyo-Jousse, Viviana; Peñaloza, Estefania; Farías, Marcelo; Uauy, Ricardo; Casanello, Paola; Krause, Bernardo J

    2017-02-15

    Intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial epigenetic programming of the umbilical vessels. There is no evidence that this epigenetic programming is occurring on systemic fetal arteries. In IUGR guinea pigs we studied the functional and epigenetic programming of endothelial nitric oxide synthase (eNOS) (Nos3 gene) in umbilical and systemic fetal arteries, addressing the role of oxidative stress in this process by maternal treatment with N-acetylcysteine (NAC) during the second half of gestation. The present study suggests that IUGR endothelial cells have common molecular markers of programming in umbilical and systemic arteries. Notably, maternal treatment with NAC restores fetal growth by increasing placental efficiency and reverting the functional and epigenetic programming of eNOS in arterial endothelium in IUGR guinea pigs. In humans, intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial programming in umbilical vessels. We aimed to determine the effects of maternal antioxidant treatment with N-acetylcysteine (NAC) on fetal endothelial function and endothelial nitric oxide synthase (eNOS) programming in IUGR guinea pigs. IUGR was induced by implanting ameroid constrictors on uterine arteries of pregnant guinea pigs at mid gestation, half of the sows receiving NAC in the drinking water (from day 34 until term). Fetal biometry and placental vascular resistance were followed by ultrasound throughout gestation. At term, umbilical arteries and fetal aortae were isolated to assess endothelial function by wire-myography. Primary cultures of endothelial cells (ECs) from fetal aorta, femoral and umbilical arteries were used to determine eNOS mRNA levels by quantitative PCR and analyse DNA methylation in the Nos3 promoter by pyrosequencing. Doppler ultrasound measurements showed that NAC reduced placental vascular resistance in IUGR (P < 0.05) and recovered fetal weight (P < 0.05), increasing fetal-to-placental ratio at term (∼40%) (P < 0.001). In IUGR, NAC treatment restored eNOS-dependent relaxation in aorta and umbilical arteries (P < 0.05), normalizing eNOS mRNA levels in EC fetal and umbilical arteries (P < 0.05). IUGR-derived ECs had a decreased DNA methylation (∼30%) at CpG -170 (from the transcription start site) and this epigenetic signature was absent in NAC-treated fetuses (P < 0.001). These data show that IUGR-ECs have common molecular markers of eNOS programming in umbilical and systemic arteries and this effect is prevented by maternal treatment with antioxidants. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  1. Prediction of microcephaly at birth using three reference ranges for fetal head circumference: can we improve prenatal diagnosis?

    PubMed

    Leibovitz, Z; Daniel-Spiegel, E; Malinger, G; Haratz, K; Tamarkin, M; Gindes, L; Schreiber, L; Ben-Sira, L; Lev, D; Shapiro, I; Bakry, H; Weizman, B; Zreik, A; Egenburg, S; Arad, A; Tepper, R; Kidron, D; Lerman-Sagie, T

    2016-05-01

    To evaluate the prediction of microcephaly at birth (micB) using established and two new reference ranges for fetal head circumference (HC) and to assess whether integrating additional parameters can improve prediction. Microcephaly in utero was defined as a fetal HC 3SD below the mean for gestational age according to Jeanty et al.'s reference range. The records of cases with fetal microcephaly (Fmic) were evaluated for medical history, imaging findings, biometry and postnatal examination/autopsy findings. Microcephaly was confirmed at birth (micB) by an occipitofrontal circumference (OFC) or a brain weight at autopsy 2SD below the mean for gestational age. The new INTERGROWTH-21(st) Project and a recent Israeli reference for fetal growth were applied for evaluation of the Fmic positive predictive value (PPV) for diagnosis of micB cases. Optimal HC cut-offs were determined for each of the new references with the aim of detecting all micB cases whilst minimizing the number of false positives found to have a normal HC at birth. We also assessed the difference between the Z-scores of the prenatal HC and the corresponding OFC at birth, the frequency of small-for-gestational age (SGA), decreased HC/abdominal circumference (AC) and HC/femur length (FL) ratios, the prevalence of associated malformations and family history. Forty-two fetuses were diagnosed as having Fmic according to the Jeanty reference, but micB was confirmed in only 24 (PPV, 57.1%). The optimal INTERGROWTH and Israeli reference HC cut-offs for micB diagnosis were mean - 3SD and mean - 2.3SD, resulting in a statistically non-significant improvement in PPV to 61.5% and 66.7%, respectively. The presence of a family history of microcephaly, SGA, associated malformations and application of stricter HC cut-offs resulted in a higher PPV of micB, although not statistically significant and with a concurrent increase in the number of false-negative results. The deviation of the HC from the mean, by all references, was significantly larger compared with the actual deviation of the OFC at birth, with mean differences between the corresponding Z-scores of -1.15, -1.95 and -0.74 for the Jeanty, INTERGROWTH and Israeli references, respectively. The evaluated reference ranges all result in considerable over-diagnosis of fetal microcephaly. The use of the two new HC reference ranges did not significantly improve micB prediction compared with that of Jeanty et al., whilst use of additional characteristics and stricter HC cut-offs could improve the PPV with an increase in false negatives. The postnatal OFC deviates significantly less from the mean compared with the prenatal HC, and we propose that adjustment for this would enable better prediction of the actual OFC deviation at birth. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  2. Assessment and restoring soil functionality in degraded areas of organic vineyards. The preliminary results of the ReSolVe project in Italy

    NASA Astrophysics Data System (ADS)

    Priori, Simone; Agnelli, Alessandro; Castaldini, Maurizio; D'Avino, Lorenzo; D'Errico, Giada; Gagnarli, Elena; Giudi, Silvia; Goggioli, Donatella; Lagomarsino, Alessandra; Landi, Silvia; Leprini, Marco; Pellegrini, Sergio; Perria, Rita; Puccioni, Sergio; Simoni, Sauro; Storchi, Paolo; Valboa, Giuseppe; Zombardo, Alessandra; Costantini, Edoardo

    2016-04-01

    In both conventional and organic Italian vineyards, it is quite common to have areas characterized by problems in vine health, grape production and quality, often caused by improper land preparation before vine plantation and/or management. Causes for soil malfunctioning can include: reduced contribution of the soil fauna to the ecosystem services (i.e. nutrient cycles), poor organic matter content, imbalance of some element ratio, altered pH, water deficiency, soil compaction and/or scarce oxygenation. ReSolVe is a transnational and interdisciplinary 3-years research project aimed at testing the effects of selected organic strategies for restoring optimal soil functionality in degraded areas within vineyard. The different restoring strategies implemented in each plot will be: i) compost produced on farm by manure + pruning residue + grass, ii) faba bean and barley green manure, iii) sowing and dry mulching with Trifolium squarrosum L. During two years of such treatments, the trend of the soil features and the grapevine status will be monitored in detail, to reveal the positive and negative effects of such treatments. The project involves 8 research groups in 6 different EU countries (Italy, France, Spain, Sweden, Slovenia, and Turkey), with experts from several disciplines, including soil science, ecology, microbiology, grapevine physiology, viticulture, and biometry. The experimental vineyards are situated in Italy (Chianti hills and Maremma plain, Tuscany), France (Bordeaux and Languedoc), Spain (La Rioja) and Slovenia (Primorska) for winegrape, and in Turkey (Adana and Mersin) for table grape. Soil features before implementing restoring strategies showed lower content of soil organic matter and enzyme activities, and higher carbonates in degraded areas than in the non-degraded areas. The Biological Soil Quality values of microarthropods were always high, in comparison with data registered in similarly managed vineyards or stable ecosystems, and the data showed homogeneous patterns within the experimental plots. Nematode abundance, taxa richness and maturity (MI) and plant parasitic (PPI) indices were higher in non-degraded than degraded areas, but differences were not significant. Grapevines in degraded areas of both farms showed less vegetative vigour and significantly lower values in the SPAD colour index. The yield and the weight of the grape bunches and berries were greater in the not degraded. The grapes of degraded areas at harvest had instead a sugar content significantly higher (on average +2.5°Brix). The restoration techniques and the monitoring methodologies developed and tested during the ReSolVe project will be described in specific final guidelines. The restoration techniques will be accessible for all the European farmers and will be low cost and environmental-friendly. A protocol of analyses and measurements between the all partners will allow an effective and comparable monitoring of vineyard ecosystemic functioning in European countries. Keywords: organic, viticulture, soil functionality, biodiversity, soil management Aknowledgements: Financial support for this project is provided by funding bodies within the FP7 ERA-Net CORE Organic Plus, and cofunds from the European Commission.

  3. [Role of ST-analysis of fetal ECG in intrapartal fetus monitoring with presumed growth retardation].

    PubMed

    Hruban, L; Janků, P; Zahradnícková, J; Kurecová, B; Roztocil, A; Kachlík, P; Kucera, M; Jelenek, G

    2006-07-01

    Evaluation of the role of ST analysis of fetus ECG for early detection of developing acute hypoxia in the course of delivery of fetuses with presumed growth retardation. A comparison with present way of intrapartal fetus monitoring. Impact on the number of surgical births for indications of threatening fetus hypoxia. Influence of the method on perinatal results and postnatal adaptation of the newborns. A prospective study. Gynecology-Obstetrics Clinic, Masaryk University and Teaching Hospital Brno. Forty seven women with a growth retardation of the fetus diagnosed before delivery who gave birth in the Teaching Hospital in Brno during 2003-2005 and intrapartal ST analysis of fetus ECG was subsequently used, were enrolled into this prospective study (group A). The control group consisted of 87 deliveries taking place in the same period of time and concerning women with fetuses suffering from growth retardation and monitored by standard methods (group B). The standard methods included cardiotocography (CTG), supplemented with pulse oximetry (IFPO) if needed. The diagnosis of intrauterine fetus growth retardation was established on the basis of the results of repeated prepartal ultrasound fetus biometry with estimation of the mass, which corresponded to a group below 10 percentile for the given gestational age. The numbers of vaginal deliveries and surgically treated delivery due to threatening fetus hypoxia (Cesarean section, forceps delivery) were recorded. The authors evaluated postpartal pH from umbilical artery, independently for the group of values of pH < 7.00, the group of pH 7.00-0.10 and pH 7.10 or more. The values of Apgar score were evaluated for the first, fifth and tenth minute, respectively. The neonatologist followed the duration of stay of the newborn at the Newborn Intensive Care Unit, the Intermediate Care Unit, total duration of hospitalization, the occurrence of sepsis in the early newbotn period, the occurrence of hyperbilirubinemia, and the conclusion of neurological examination. All the results were evaluated statistically by the chi2 test, Kruskal-Wallis test or the Anova method. There was no statistically significantly difference in the number of delivery ended by surgery for threatening fetus hypoxia (p = 0.856) or the detection rate of intrapartal hypoxia according to pH values of umbilical blood divided into the three groups (p = 0.657, p = 0.958, p = 0.730, respectively). The values of Apgar score differed in favor of the group A significantly only in the first minute at the level of 5% opf significance (p = 0.018). The values of Apgar score in the fifth and tenth minute did not show any significant difference (P = 0301 and p = 0313, respectively). There was no statistically significant difference in neonatological results between the group A and B. The use of ST analysis of fetal ECG in the course of delivery of fetuses with presumed intrauterine growth retardation did not show any significant difference from the presently used methods (CTG supplemented with IFPO if needed). In using the method there was not any effect on the number of surgically treated deliveries for indications of threatening acute fetus hypoxia or perinatal results and postnatal adaptation of the newborns.

  4. Prediction of adverse pregnancy outcome in monochorionic- diamniotic twin pregnancies complicated by selective fetal growth restriction.

    PubMed

    Monaghan, Caitriona; Kalafat, Erkan; Binder, Julia; Thilaganathan, Baskaran; Khalil, Asma

    2018-04-28

    To identify key factors implicated in adverse perinatal outcome in monochorionic twin pregnancies complicated by selective fetal growth restriction. This is a retrospective cohort study conducted in a single tertiary referral centre included all monochorionic diamniotic (MCDA) twin pregnancies complicated by selective fetal growth restriction (sFGR). The presence of co-existing twin to twin transfusion syndrome (TTTS) was noted. Fetal biometry and Doppler indices, including the umbilical artery (UA) and ductus venosus (DV), were recorded at the time of diagnosis. The type of sFGR was diagnosed according to the pattern of end-diastolic flow (EDF) in the UA of the smaller twin. DV pulsatility indices were converted to z-scores and estimated fetal weight (EFW) values to centiles, to correct for gestational age (GA). Cox proportional hazards model was used to examine for independent predictors of adverse perinatal outcome. Adverse perinatal outcome was defined according to survival and included both intra-uterine fetal demise and neonatal death of the FGR twin. We analysed 104 pregnancies complicated by sFGR. Sixty-six (63.5%) were diagnosed with type I and 38 (36.5%) with type II at initial presentation. Pregnancies complicated by type II sFGR were diagnosed (median GA 19.6 weeks' vs 21.5 weeks, p=0.012) and delivered (median GA 30.4 weeks' vs 32.57 weeks; p=0.055) earlier and are associated with increased risk of adverse perinatal outcomes (intrauterine demise of the smaller twin 19.7% vs 10.6%, p=0.001), when compared to type I sFGR. Twin pregnancies complicated by sFGR, whether type I or II, resulting in intrauterine demise have a significantly earlier onset of diagnosis (p<0.001), earlier GA at delivery (p<0.05), higher DV pulsatility index (p<0.05), and lower birth weight (BW) centile of the smaller twin (p<0.01) when compared to pregnancies resulting in livebirth. Co-existing TTTS had no significant impact on the perinatal outcome of pregnancies diagnosed with either type I or type II sFGR (p>0.05 for both). Earlier GA at diagnosis (HR 0.70, 95% CI 0.56-0.88; p=0.002), type II sFGR (HR 3.53, 95% CI 1.37-9.07; p=0.008) and higher DV PI z scores (HR 1.36, 95% CI 1.12-1.65; p=0.001) were significantly associated with increased risk of adverse perinatal outcome of the smaller twin. Pregnancies complicated by type II sFGR are diagnosed significantly earlier and are associated with increased risk of adverse perinatal outcomes when compared to type I. Co-existing TTTS has no significant impact on the perinatal outcome of pregnancies diagnosed with either type I or type II sFGR. Earlier GA at diagnosis, type II sFGR and higher DV PI z scores are significantly associated with increased risk of adverse perinatal outcome for the smaller twin. This article is protected by copyright. All rights reserved.

  5. Sonographic large fetal head circumference and risk of cesarean delivery.

    PubMed

    Lipschuetz, Michal; Cohen, Sarah M; Israel, Ariel; Baron, Joel; Porat, Shay; Valsky, Dan V; Yagel, Oren; Amsalem, Hagai; Kabiri, Doron; Gilboa, Yinon; Sivan, Eyal; Unger, Ron; Schiff, Eyal; Hershkovitz, Reli; Yagel, Simcha

    2018-03-01

    Persistently high rates of cesarean deliveries are cause for concern for physicians, patients, and health systems. Prelabor assessment might be refined by identifying factors that help predict an individual patient's risk of cesarean delivery. Such factors may contribute to patient safety and satisfaction as well as health system planning and resource allocation. In an earlier study, neonatal head circumference was shown to be more strongly associated with delivery mode and other outcome measures than neonatal birthweight. In the present study we aimed to evaluate the association of sonographically measured fetal head circumference measured within 1 week of delivery with delivery mode. This was a multicenter electronic medical record-based study of birth outcomes of primiparous women with term (37-42 weeks) singleton fetuses presenting for ultrasound with fetal biometry within 1 week of delivery. Fetal head circumference and estimated fetal weight were correlated with maternal background, obstetric, and neonatal outcome parameters. Elective cesarean deliveries were excluded. Multinomial regression analysis provided adjusted odds ratios for instrumental delivery and unplanned cesarean delivery when the fetal head circumference was ≥35 cm or estimated fetal weight ≥3900 g, while controlling for possible confounders. In all, 11,500 cases were collected; 906 elective cesarean deliveries were excluded. A fetal head circumference ≥35 cm increased the risk for unplanned cesarean delivery: 174 fetuses with fetal head circumference ≥35 cm (32%) were delivered by cesarean, vs 1712 (17%) when fetal head circumference <35 cm (odds ratio, 2.49; 95% confidence interval, 2.04-3.03). A fetal head circumference ≥35 cm increased the risk of instrumental delivery (odds ratio, 1.48; 95% confidence interval, 1.16-1.88), while estimated fetal weight ≥3900 g tended to reduce it (nonsignificant). Multinomial regression analysis showed that fetal head circumference ≥35 cm increased the risk of unplanned cesarean delivery by an adjusted odds ratio of 1.75 (95% confidence interval, 1.4-2.18) controlling for gestational age, fetal gender, and epidural anesthesia. The rate of prolonged second stage of labor was significantly increased when either the fetal head circumference was ≥35 cm or the estimated fetal weight ≥3900 g, from 22.7% in the total cohort to 31.0%. A fetal head circumference ≥35 cm was associated with a higher rate of 5-minute Apgar score ≤7: 9 (1.7%) vs 63 (0.6%) of infants with fetal head circumference <35 cm (P = .01). The rate among fetuses with an estimated fetal weight ≥3900 g was not significantly increased. The rate of admission to the neonatal intensive care unit did not differ among the groups. Sonographic fetal head circumference ≥35 cm, measured within 1 week of delivery, is an independent risk factor for unplanned cesarean delivery but not instrumental delivery. Both fetal head circumference ≥35 cm and estimated fetal weight ≥3900 g significantly increased the risk of a prolonged second stage of labor. Fetal head circumference measurement in the last days before delivery may be an important adjunct to estimated fetal weight in labor management. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Sources of Wilhelm Johannsen's genotype theory.

    PubMed

    Roll-Hansen, Nils

    2009-01-01

    This paper describes the historical background and early formation of Wilhelm Johannsen's distinction between genotype and phenotype. It is argued that contrary to a widely accepted interpretation (For instance, W. Provine, 1971. The Origins of Theoretical Population Genetics. Chicago: The University of Chicago Press; Mayr, 1973; F. B. Churchill, 1974. Journal of the History of Biology 7: 5-30; E. Mayr, 1982. The Growth of Biological Thought, Cambridge: Harvard University Press; J. Sapp, 2003. Genesis. The Evolution of Biology. New York: Oxford University Press) his concepts referred primarily to properties of individual organisms and not to statistical averages. Johannsen's concept of genotype was derived from the idea of species in the tradition of biological systematics from Linnaeus to de Vries: An individual belonged to a group - species, subspecies, elementary species - by representing a certain underlying type (S. Müller-Wille and V. Orel, 2007. Annals of Science 64: 171-215). Johannsen sharpened this idea theoretically in the light of recent biological discoveries, not least those of cytology. He tested and confirmed it experimentally combining the methods of biometry, as developed by Francis Galton, with the individual selection method and pedigree analysis, as developed for instance by Louis Vilmorin. The term "genotype" was introduced in W. Johannsen's 1909 (Elemente der Exakten Erblichkeitslehre. Jena: Gustav Fischer) treatise, but the idea of a stable underlying biological "type" distinct from observable properties was the core idea of his classical bean selection experiment published 6 years earlier (W. Johannsen, 1903. Ueber Erblichkeit in Populationen und reinen Linien. Eine Beitrag zur Beleuchtung schwebender Selektionsfragen, Jena: Gustav Fischer, pp. 58-59). The individual ontological foundation of population analysis was a self-evident presupposition in Johannsen's studies of heredity in populations from their start in the early 1890s till his death in 1927. The claim that there was a "substantial but cautious modification of Johannsen's phenotype-genotype distinction" (Churchill, 1974, p. 24) from a statistical to an individual ontological perspective derives from a misreading of the 1903 and 1909 texts. The immediate purpose of this paper is to correct this reading of the 1903 monograph by showing how its problems and results grow out of Johannsen's earlier work in heredity and plant breeding. Johannsen presented his famous selection experiment as the culmination of a line of criticism of orthodox Darwinism by William Bateson, Hugo de Vries, and others (Johannsen, 1903). They had argued that evolution is based on stepwise rather than continuous change in heredity. Johannsen's paradigmatic experiment showed how stepwise variation in heredity could be operationally distinguished from the observable, continuous morphological variation. To test Galton's law of partial regression, Johannsen deliberately chose pure lines of self-fertilizing plants, a pure line being the descendants in successive generations of one single individual. Such a population could be assumed to be highly homogeneous with respect to hereditary type, and Johannsen found that selection produced no change in this type. Galton, he explained, had experimented with populations composed of a number of stable hereditary types. The partial regression which Galton found was simply an effect of selection between types, increasing the proportion of some types at the expense of others.

  7. Comparison between carbachol iontophoresis and intravenous pilocarpine stimulated accommodation in anesthetized rhesus monkeys.

    PubMed

    Wendt, Mark; He, Lin; Glasser, Adrian

    2013-10-01

    Rhesus monkeys are an animal model for human accommodation and presbyopia and consistent and repeatable methods are needed to stimulate and measure accommodation in anesthetized rhesus monkeys. Accommodation has typically been pharmacologically stimulated with topical pilocarpine or carbachol iontophoresis. Intravenous (i.v.) pilocarpine has recently been shown to produce more natural, rapid and reproducible accommodative responses compared to topical pilocarpine. Here, i.v. pilocarpine was compared to carbachol iontophoresis stimulated accommodation. Experiments were performed under anaesthesia on five previously iridectomized monkeys aged 10-16 years. In three monkeys, accommodation was stimulated with carbachol iontophoresis in five successive experiments and refraction measured with a Hartinger coincidence refractometer. In separate experiments, accommodation was stimulated using a 5 mg/kg bolus of i.v. pilocarpine given over 30 s followed by a continuous infusion of 20 mg/kg/hr for 5.5 min in three successive experiments with the same monkeys as well as in single experiments with two additional monkeys. Refraction was measured continuously using photorefraction with baseline and accommodated refraction also measured with the Hartinger. In subsequent i.v. pilocarpine experiments with each monkey, accommodative changes in lens equatorial diameter were measured in real-time with video-image analysis. Maximum accommodation of three monkeys with carbachol iontophoresis (five repeats) was (mean ± SD; range) 14.0 ± 3.5; 9.9-20.3 D and with i.v. pilocarpine stimulation (three repeats) was 11.1 ± 1.1; 9.9-13.0 D. The average of the standard deviations of maximum accommodation from each monkey was 0.8 ± 0.3 D from carbachol iontophoresis and 0.3 ± 0.2 from i.v. pilocarpine. The average latency to the start of the response after carbachol iontophoresis was 2.5 ± 3.9; 0.0-12.0 min with a time constant of 12.7 ± 9.5; 2.3-29.2 min. The average latency after i.v. pilocarpine was 0.31 ± 0.03; 0.25-0.34 min with a time constant of 0.19 ± 0.07; 0.11-0.31 s. During i.v. pilocarpine stimulated accommodation in five monkeys, lens diameters decreased by 0.54 ± 0.09; 0.42-0.64 mm with a rate of change of 0.052 ± 0.002; 0.050-0.055 mm/D. Accommodative responses with i.v. pilocarpine were more rapid, consistent and stable than those with carbachol iontophoresis. The accommodative decrease in lens diameter with i.v. pilocarpine as a function of age was consistent with previous results using constant topical pilocarpine. Intravenous pilocarpine stimulated accommodation is safe, more consistent and more rapid than carbachol iontophoresis and it requires no contact with or obstruction of the eye thus allowing continuous and uninterrupted refraction and ocular biometry measurements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. The World Health Organization fetal growth charts: concept, findings, interpretation, and application.

    PubMed

    Kiserud, Torvid; Benachi, Alexandra; Hecher, Kurt; Perez, Rogelio González; Carvalho, José; Piaggio, Gilda; Platt, Lawrence D

    2018-02-01

    Ultrasound biometry is an important clinical tool for the identification, monitoring, and management of fetal growth restriction and development of macrosomia. This is even truer in populations in which perinatal morbidity and mortality rates are high, which is a reason that much effort is put onto making the technique available everywhere, including low-income societies. Until recently, however, commonly used reference ranges were based on single populations largely from industrialized countries. Thus, the World Health Organization prioritized the establishment of fetal growth charts for international use. New fetal growth charts for common fetal measurements and estimated fetal weight were based on a longitudinal study of 1387 low-risk pregnant women from 10 countries (Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand) that provided 8203 sets of ultrasound measurements. The participants were characterized by median age 28 years, 58% nulliparous, normal body mass index, with no socioeconomic or nutritional constraints (median caloric intake, 1840 calories/day), and had the ability to attend the ultrasound sessions, thus essentially representing urban populations. Median gestational age at birth was 39 weeks, and birthweight was 3300 g, both with significant differences among countries. Quantile regression was used to establish the fetal growth charts, which also made it possible to demonstrate a number of features of fetal growth that previously were not well appreciated or unknown: (1) There was an asymmetric distribution of estimated fetal weight in the population. During early second trimester, the distribution was wider among fetuses <50th percentile compared with those above. The pattern was reversed in the third trimester, with a notably wider variation >50th percentile. (2) Although fetal sex, maternal factors (height, weight, age, and parity), and country had significant influence on fetal weight (1-4.5% each), their effect was graded across the percentiles. For example, the positive effect of maternal height on fetal weight was strongest on the lowest percentiles and smallest on the highest percentiles for estimated fetal weight. (3) When adjustment was made for maternal covariates, there was still a significant effect of country as covariate that indicated that ethnic, cultural, and geographic variation play a role. (4) Variation between populations was not restricted to fetal size because there were also differences in growth trajectories. (5) The wide physiologic ranges, as illustrated by the 5th-95th percentile for estimated fetal weight being 2205-3538 g at 37 weeks gestation, signify that human fetal growth under optimized maternal conditions is not uniform. Rather, it has a remarkable variation that largely is unexplained by commonly known factors. We suggest this variation could be part of our common biologic strategy that makes human evolution extremely successful. The World Health Organization fetal growth charts are intended to be used internationally based on low-risk pregnancies from populations in Africa, Asia, Europe, and South America. We consider it prudent to test and monitor whether the growth charts' performance meets the local needs, because refinements are possible by a change in cut-offs or customization for fetal sex, maternal factors, and populations. In the same line, the study finding of variations emphasizes the need for carefully adjusted growth charts that reflect optimal local growth when public health issues are addressed. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. A new customized fetal growth standard for African American women: the PRB/NICHD Detroit Study

    PubMed Central

    Tarca, Adi L.; Romero, Roberto; Gudicha, Dereje W.; Erez, Offer; Hernandez-Andrade, Edgar; Yeo, Lami; Bhatti, Gaurav; Pacora, Percy; Maymon, Eli; Hassan, Sonia S.

    2018-01-01

    Background The assessment of fetal growth disorders requires a standard. Current nomograms for the assessment of fetal growth in African American women have been derived either from neonatal (rather than fetal) biometry data or have not been customized for maternal ethnicity, weight, height, parity, and fetal sex. Objective We sought to 1) develop a new customized fetal growth standard for African American mothers; and 2) compare such a standard to three existing standards for the classification of fetuses as small (SGA) or large (LGA) for gestational age. Study Design A retrospective cohort study included 4,183 women (4,001 African American and 182 Caucasian) from the Detroit metropolitan area who underwent ultrasound examinations between 14 and 40 weeks of gestation (the median number of scans per pregnancy was 5, interquartile range 3-7) and for whom relevant covariate data were available. Longitudinal quantile regression was used to build models defining the “normal” estimated fetal weight (EFW) centiles for gestational age in African American women, adjusted for maternal height, weight, parity, and fetal sex, and excluding pathologic factors with a significant effect on fetal weight. The resulting Perinatology Research Branch/Eunice Kennedy Shriver National Institute of Child Health and Human Development (hereinafter, PRB/NICHD) growth standard was compared to 3 other existing standards—the customized gestation-related optimal weight (GROW) standard; the Eunice Kennedy Shriver National Institute of Child Health and Human Development (hereinafter, NICHD) African American standard; and the multinational World Health Organization (WHO) standard—utilized to screen fetuses for SGA (<10th centile) or LGA (>90th centile) based on the last available ultrasound examination for each pregnancy. Results 1) First, the mean birthweight at 40 weeks was 133g higher for neonates born to Caucasian than to African American mothers and 150g higher for male than female neonates; maternal weight, height, and parity had a positive effect on birthweight.Second, analysis of longitudinal EFW revealed the following features of fetal growth: (1) all weight centiles were about 2% higher for male than for female fetuses; (2) maternal height had a positive effect on EFW, with larger fetuses being affected more (2% increase in the 95th centile of weight for each 10-cm increase in height); and (3) maternal weight and parity had a positive effect on EFW that increased with gestation and varied among the weight centiles. Third, the screen-positive rate for SGA was 7.2% for the NICHD African American standard, 12.3% for the GROW standard, 13% for the WHO standard customized by fetal sex, and 14.4% for the PRB/NICHD customized standard. For all standards, the screen-positive rate for SGA was at least two-fold higher among fetuses delivered preterm than at term.Fourth, the screen-positive rate for LGA was 8.7% for the GROW standard, 9.2% for the PRB/NICHD customized standard, 10.8% for the WHO standard customized by fetal sex, and 12.3% for the NICHD African American standard. Finally, the highest overall agreement among standards was between the GROW and PRB/NICHD customized standards (Cohen’s inter-rater agreement, kappa=0.85). Conclusions We developed a novel customized PRB/NICHD fetal growth standard from fetal data in an African American population without assuming proportionality of the effects of covariates and also without assuming that these effects are equal on all centiles of weight; we also provide an easy-to-use centile calculator. This standard classified more fetuses as being at risk for SGA compared to existing standards, especially among fetuses delivered preterm, but classified about the same number of LGA fetuses. The comparison among the four growth standards also revealed that the most important factor determining agreement among standards is whether they account for the same factors known to affect fetal growth. PMID:29422207

  10. Femur-sparing pattern of abnormal fetal growth in pregnant women from New York City after maternal Zika virus infection.

    PubMed

    Walker, Christie L; Merriam, Audrey A; Ohuma, Eric O; Dighe, Manjiri K; Gale, Michael; Rajagopal, Lakshmi; Papageorghiou, Aris T; Gyamfi-Bannerman, Cynthia; Adams Waldorf, Kristina M

    2018-05-05

    Zika virus is a mosquito-transmitted flavivirus, which can induce fetal brain injury and growth restriction following maternal infection during pregnancy. Prenatal diagnosis of Zika virus-associated fetal injury in the absence of microcephaly is challenging due to an incomplete understanding of how maternal Zika virus infection affects fetal growth and the use of different sonographic reference standards around the world. We hypothesized that skeletal growth is unaffected by Zika virus infection and that the femur length can represent an internal standard to detect growth deceleration of the fetal head and/or abdomen by ultrasound. We sought to determine if maternal Zika virus infection is associated with a femur-sparing pattern of intrauterine growth restriction through analysis of fetal biometric measures and/or body ratios using the 2014 International Fetal and Newborn Growth Consortium for the 21st Century Project and World Health Organization Fetal Growth Chart sonographic references. Pregnant women diagnosed with a possible recent Zika virus infection at Columbia University Medical Center after traveling to an endemic area were retrospectively identified and included if a fetal ultrasound was performed. Data were collected regarding Zika virus testing, fetal biometry, pregnancy, and neonatal outcomes. The 2014 International Fetal and Newborn Growth Consortium for the 21st Century Project and World Health Organization Fetal Growth Chart sonographic standards were applied to obtain Z-scores and/or percentiles for fetal head circumference, abdominal circumference, and femur length specific for each gestational week. A novel 2014 International Fetal and Newborn Growth Consortium for the 21st Century Project standard was also developed to generate Z-scores for fetal body ratios with respect to femur length (head circumference:femur length, abdominal circumference:femur length). Data were then grouped within clinically relevant gestational age strata (<24, 24-27 6/7, 28-33 6/7, >34 weeks) to analyze time-dependent effects of Zika virus infection on fetal size. Statistical analysis was performed using Wilcoxon signed-rank test on paired data, comparing either abdominal circumference or head circumference to femur length. A total of 56 pregnant women were included in the study with laboratory evidence of a confirmed or possible recent Zika virus infection. Based on the Centers for Disease Control and Prevention definition for microcephaly after congenital Zika virus exposure, microcephaly was diagnosed in 5% (3/56) by both the 2014 International Fetal and Newborn Growth Consortium for the 21st Century Project and World Health Organization Fetal Growth Chart standards (head circumference Z-score ≤-2 or ≤2.3%). Using 2014 International Fetal and Newborn Growth Consortium for the 21st Century Project, intrauterine fetal growth restriction was diagnosed in 18% of pregnancies (10/56; abdominal circumference Z-score ≤-1.3, <10%). Analysis of fetal size using the last ultrasound scan for all subjects revealed a significantly abnormal skewing of fetal biometrics with a smaller abdominal circumference vs femur length by either 2014 International Fetal and Newborn Growth Consortium for the 21st Century Project or World Health Organization Fetal Growth Chart (P < .001 for both). A difference in distribution of fetal abdominal circumference compared to femur length was first apparent in the 24-27 6/7 week strata (2014 International Fetal and Newborn Growth Consortium for the 21st Century Project, P = .002; World Health Organization Fetal Growth Chart, P = .001). A significantly smaller head circumference compared to femur length was also observed by 2014 International Fetal and Newborn Growth Consortium for the 21st Century Project as early as the 28-33 6/7 week strata (2014 International Fetal and Newborn Growth Consortium for the 21st Century Project, P = .007). Overall, a femur-sparing pattern of growth restriction was detected in 52% of pregnancies with either head circumference:femur length or abdominal circumference:femur length fetal body ratio <10th percentile (2014 International Fetal and Newborn Growth Consortium for the 21st Century Project Z-score ≤-1.3). An unusual femur-sparing pattern of fetal growth restriction was detected in the majority of fetuses with congenital Zika virus exposure. Fetal body ratios may represent a more sensitive ultrasound biomarker to detect viral injury in nonmicrocephalic fetuses that could impart long-term risk for complications of congenital Zika virus infection. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. A new mountain lizard from Montes de León (NW Iberian Peninsula): Iberolacerta monticola astur ssp. nov. (Squamata: Lacertidae).

    PubMed

    Arribas, Oscar J; Galán, Pedro; Remón, Núria; Naveira, Horacio

    2014-05-19

    Iberolacerta populations from the Northern Montes de Leon (NML) were studied by means of external morphology (scalation and biometry), osteology and genetics (mtDNA and microsatellites), searching for their homogeneity ("intrazonalanalysis") and, once verified, comparing them with Iberolacerta monticola s. str. (from Central Cantabrian Mountains)and/. gal ani (from Southern Montes de Leon) ("extrazonal analysis") from neighboring areas.Our "intrazonal analysis" revealed discordances between the different approaches, especially the patterns of variation of nuclear microsatellites (congruent with external morphology) and mtDNA, namely a very low nuclear differentiation between relatively highly differentiated mtDNA lineages. The morphological approach was unable to discriminate any of the populations as significantly different from the others in the NML. Mitochondrial DNA revealed a haplotype lineage closely related to I. galani (MNL-II in our text) in some specimens of Sierra de Villabandfn and Suspiron, but these populations are morphologically indistinguishable from the main part of the other populations that belong to lineage NML-1,phylogenetically closer to/. monticola. After a separation from I. manti cola ca. 1.8 Mya, the populations in this geographic region must have suffered at least two different waves of gene flow from I. gal ani, the second one not much later than 0.5 Mya. Microsatellite results indicate that all the NML populations are genetically similar in terms of their nuclear genomes,independently of their mitochondrial differentiation (NML-I vs. NML-II haplotype groups). Since all the morphological and microsatellite evidences point towards the fact that, independently of the mitochondrial haplotypes that they bear (NML-1 or NML-II), there is only one taxon in the area, we describe it as: Iberolacerta monticola astur ssp. nov.Concerning the relationships of I. m. astur ssp. nov. with I. monticola s. str. and I. gal ani ("extra zonal analysis"), in the female analyses the new taxon centroid is closer to I. monticola s. str. than to I. gal ani (more similarity with I manticolas.str.), whereas in the male analyses the relationship is just the contrary (closer to I. gal ani, paralleling the direction of the hypothesized past hybridization). Moreover, in both sexes' ANOVA, I. m. astur ssp. nov. results more similar (lessP<0.05 differences) to I. galani than to I. monticola s. str. Osteologically, I. m. astur ssp. nov. is slightly more similar toI. monticola s. str. than to I. galani, especially in the squamosal bone, which is regularly arched (primitive shape). Genetically,as indicated above, the NML populations can be subdivided in two groups according to their mitochondrial DNA,namely NML-I (bearing clearly differentiated haplotypes, phylogenetically closer to I. monticola) and NML-II (whose haplotypes could have been mistaken for those of an I. gal ani population). This mitochondrial subdivision has at most a subtle nuclear correlate, however. According to the nuclear microsatellite markers, all the NML populations belong to a single group(/. m. astur ssp. nov.), which would be more similar to I. gal ani than to I monticola, with NML-II populations lying closer to I. galani than those from the NML-I group and, correspondingly, more distant from I. monticola. The discordant phylogenetic signal of mitochondrial and nuclear markers is discussed in terms of past introgression events and sex-biases in phylopatry and dispersion in these species. Iberolacerta manti cola astur ssp. nov., inhabits the Northern Montes de Leon (Sierra de Gistreo sensu latissimo ): Gistredo,Catoute, Tambaron, Nevadfn, Villabandfn (or Macizo del Alto de Ia Canada), Arcos del Agua (or Fernan Perez),Tiendas and Suspiron, mainly in quartzite and slate rock substrates. Its current distribution, cornered in the NW of theNorthern part of the Montes de Leon, suggests a possible competitive exclusion between this taxon and/. galani, as the galani haplotypes (NML-II) appear cornered in the most harsh and continental areas, speaking also about a, even in the past, very limited presence of this species in the area that probably was soon absorbed by I. m. astur ssp. nov. (with NMLI haplotypes). Variation in watershed limits (especially with l montico/a s. str. in the North) and Pleistocene climatic oscillations(with I. gal ani in the South) probably played a crucial role in isolation of the different Iberolacerta colonizationwaves in this zone. These changes in the boundaries among watersheds limited the contact between the NML and the main Cantabrian Mountains, restricting to narrow points (different along time) the contact between the two ranges, and thus,the areas for possible contact between I. m. astur ssp. nov. and I. monticola s. str. (see Fig. lB). The origin of this tax on dates back to the end of Pliocene or Lower Pleistocene (around 1.8 Mya), according to mtDNA divergence. On the other side, climatic oscillations allowed expansion and contact with the more continental harsh climate-dwelling I. gal ani.

Top