Javidi, Soroush; Mandic, Danilo P.; Took, Clive Cheong; Cichocki, Andrzej
2011-01-01
A new class of complex domain blind source extraction algorithms suitable for the extraction of both circular and non-circular complex signals is proposed. This is achieved through sequential extraction based on the degree of kurtosis and in the presence of non-circular measurement noise. The existence and uniqueness analysis of the solution is followed by a study of fast converging variants of the algorithm. The performance is first assessed through simulations on well understood benchmark signals, followed by a case study on real-time artifact removal from EEG signals, verified using both qualitative and quantitative metrics. The results illustrate the power of the proposed approach in real-time blind extraction of general complex-valued sources. PMID:22319461
Time-frequency approach to underdetermined blind source separation.
Xie, Shengli; Yang, Liu; Yang, Jun-Mei; Zhou, Guoxu; Xiang, Yong
2012-02-01
This paper presents a new time-frequency (TF) underdetermined blind source separation approach based on Wigner-Ville distribution (WVD) and Khatri-Rao product to separate N non-stationary sources from M(M <; N) mixtures. First, an improved method is proposed for estimating the mixing matrix, where the negative value of the auto WVD of the sources is fully considered. Then after extracting all the auto-term TF points, the auto WVD value of the sources at every auto-term TF point can be found out exactly with the proposed approach no matter how many active sources there are as long as N ≤ 2M-1. Further discussion about the extraction of auto-term TF points is made and finally the numerical simulation results are presented to show the superiority of the proposed algorithm by comparing it with the existing ones.
Joint Blind Source Separation by Multi-set Canonical Correlation Analysis
Li, Yi-Ou; Adalı, Tülay; Wang, Wei; Calhoun, Vince D
2009-01-01
In this work, we introduce a simple and effective scheme to achieve joint blind source separation (BSS) of multiple datasets using multi-set canonical correlation analysis (M-CCA) [1]. We first propose a generative model of joint BSS based on the correlation of latent sources within and between datasets. We specify source separability conditions, and show that, when the conditions are satisfied, the group of corresponding sources from each dataset can be jointly extracted by M-CCA through maximization of correlation among the extracted sources. We compare source separation performance of the M-CCA scheme with other joint BSS methods and demonstrate the superior performance of the M-CCA scheme in achieving joint BSS for a large number of datasets, group of corresponding sources with heterogeneous correlation values, and complex-valued sources with circular and non-circular distributions. We apply M-CCA to analysis of functional magnetic resonance imaging (fMRI) data from multiple subjects and show its utility in estimating meaningful brain activations from a visuomotor task. PMID:20221319
Cultured Cortical Neurons Can Perform Blind Source Separation According to the Free-Energy Principle
Isomura, Takuya; Kotani, Kiyoshi; Jimbo, Yasuhiko
2015-01-01
Blind source separation is the computation underlying the cocktail party effect––a partygoer can distinguish a particular talker’s voice from the ambient noise. Early studies indicated that the brain might use blind source separation as a signal processing strategy for sensory perception and numerous mathematical models have been proposed; however, it remains unclear how the neural networks extract particular sources from a complex mixture of inputs. We discovered that neurons in cultures of dissociated rat cortical cells could learn to represent particular sources while filtering out other signals. Specifically, the distinct classes of neurons in the culture learned to respond to the distinct sources after repeating training stimulation. Moreover, the neural network structures changed to reduce free energy, as predicted by the free-energy principle, a candidate unified theory of learning and memory, and by Jaynes’ principle of maximum entropy. This implicit learning can only be explained by some form of Hebbian plasticity. These results are the first in vitro (as opposed to in silico) demonstration of neural networks performing blind source separation, and the first formal demonstration of neuronal self-organization under the free energy principle. PMID:26690814
NASA Astrophysics Data System (ADS)
Zhou, Kenneth J.; Chen, Jun
2014-03-01
The fluorophores of malignant human breast cells change their compositions that may be exposed in the fluorescence spectroscopy and blind source separation method. The content of the fluorophores mixture media such as tryptophan, collagen, elastin, NADH, and flavin were varied according to the cancer development. The native fluorescence spectra of these key fluorophores mixture media excited by the selective excitation wavelengths of 300 nm and 340 nm were analyzed using a blind source separation method: Nonnegative Matrix Factorization (NMF). The results show that the contribution from tryptophan, NADH and flavin to the fluorescence spectra of the mixture media is proportional to the content of each fluorophore. These data present a possibility that native fluorescence spectra decomposed by NMF can be used as potential native biomarkers for cancer detection evaluation of the cancer.
Blind source separation by sparse decomposition
NASA Astrophysics Data System (ADS)
Zibulevsky, Michael; Pearlmutter, Barak A.
2000-04-01
The blind source separation problem is to extract the underlying source signals from a set of their linear mixtures, where the mixing matrix is unknown. This situation is common, eg in acoustics, radio, and medical signal processing. We exploit the property of the sources to have a sparse representation in a corresponding signal dictionary. Such a dictionary may consist of wavelets, wavelet packets, etc., or be obtained by learning from a given family of signals. Starting from the maximum a posteriori framework, which is applicable to the case of more sources than mixtures, we derive a few other categories of objective functions, which provide faster and more robust computations, when there are an equal number of sources and mixtures. Our experiments with artificial signals and with musical sounds demonstrate significantly better separation than other known techniques.
[Evoked Potential Blind Extraction Based on Fractional Lower Order Spatial Time-Frequency Matrix].
Long, Junbo; Wang, Haibin; Zha, Daifeng
2015-04-01
The impulsive electroencephalograph (EEG) noises in evoked potential (EP) signals is very strong, usually with a heavy tail and infinite variance characteristics like the acceleration noise impact, hypoxia and etc., as shown in other special tests. The noises can be described by a stable distribution model. In this paper, Wigner-Ville distribution (WVD) and pseudo Wigner-Ville distribution (PWVD) time-frequency distribution based on the fractional lower order moment are presented to be improved. We got fractional lower order WVD (FLO-WVD) and fractional lower order PWVD (FLO-PWVD) time-frequency distribution which could be suitable for a stable distribution process. We also proposed the fractional lower order spatial time-frequency distribution matrix (FLO-STFM) concept. Therefore, combining with time-frequency underdetermined blind source separation (TF-UBSS), we proposed a new fractional lower order spatial time-frequency underdetermined blind source separation (FLO-TF-UBSS) which can work in a stable distribution environment. We used the FLO-TF-UBSS algorithm to extract EPs. Simulations showed that the proposed method could effectively extract EPs in EEG noises, and the separated EPs and EEG signals based on FLO-TF-UBSS were almost the same as the original signal, but blind separation based on TF-UBSS had certain deviation. The correlation coefficient of the FLO-TF-UBSS algorithm was higher than the TF-UBSS algorithm when generalized signal-to-noise ratio (GSNR) changed from 10 dB to 30 dB and a varied from 1. 06 to 1. 94, and was approximately e- qual to 1. Hence, the proposed FLO-TF-UBSS method might be better than the TF-UBSS algorithm based on second order for extracting EP signal under an EEG noise environment.
Source Pulse Estimation of Mine Shock by Blind Deconvolution
NASA Astrophysics Data System (ADS)
Makowski, R.
The objective of seismic signal deconvolution is to extract from the signal information concerning the rockmass or the signal in the source of the shock. In the case of blind deconvolution, we have to extract information regarding both quantities. Many methods of deconvolution made use of in prospective seismology were found to be of minor utility when applied to shock-induced signals recorded in the mines of the Lubin Copper District. The lack of effectiveness should be attributed to the inadequacy of the model on which the methods are based, with respect to the propagation conditions for that type of signal. Each of the blind deconvolution methods involves a number of assumptions; hence, only if these assumptions are fulfilled, we may expect reliable results.Consequently, we had to formulate a different model for the signals recorded in the copper mines of the Lubin District. The model is based on the following assumptions: (1) The signal emitted by the sh ock source is a short-term signal. (2) The signal transmitting system (rockmass) constitutes a parallel connection of elementary systems. (3) The elementary systems are of resonant type. Such a model seems to be justified by the geological structure as well as by the positions of the shock foci and seismometers. The results of time-frequency transformation also support the dominance of resonant-type propagation.Making use of the model, a new method for the blind deconvolution of seismic signals has been proposed. The adequacy of the new model, as well as the efficiency of the proposed method, has been confirmed by the results of blind deconvolution. The slight approximation errors obtained with a small number of approximating elements additionally corroborate the adequacy of the model.
NASA Astrophysics Data System (ADS)
Delvecchio, S.; Antoni, J.
2012-02-01
This paper addresses the use of a cyclostationary blind source separation algorithm (namely RRCR) to extract angle deterministic signals from mechanical rotating machines in presence of stationary speed fluctuations. This means that only phase fluctuations while machine is running in steady-state conditions are considered while run-up or run-down speed variations are not taken into account. The machine is also supposed to run in idle conditions so non-stationary phenomena due to the load are not considered. It is theoretically assessed that in such operating conditions the deterministic (periodic) signal in the angle domain becomes cyclostationary at first and second orders in the time domain. This fact justifies the use of the RRCR algorithm, which is able to directly extract the angle deterministic signal from the time domain without performing any kind of interpolation. This is particularly valuable when angular resampling fails because of uncontrolled speed fluctuations. The capability of the proposed approach is verified by means of simulated and actual vibration signals captured on a pneumatic screwdriver handle. In this particular case not only the extraction of the angle deterministic part can be performed but also the separation of the main sources of excitation (i.e. motor shaft imbalance, epyciloidal gear meshing and air pressure forces) affecting the user hand during operations.
NASA Astrophysics Data System (ADS)
Laassiri, M.; Hamzaoui, E.-M.; Cherkaoui El Moursli, R.
2018-02-01
Inside nuclear reactors, gamma-rays emitted from nuclei together with the neutrons introduce unwanted backgrounds in neutron spectra. For this reason, powerful extraction methods are needed to extract useful neutron signal from recorded mixture and thus to obtain clearer neutron flux spectrum. Actually, several techniques have been developed to discriminate between neutrons and gamma-rays in a mixed radiation field. Most of these techniques, tackle using analogue discrimination methods. Others propose to use some organic scintillators to achieve the discrimination task. Recently, systems based on digital signal processors are commercially available to replace the analog systems. As alternative to these systems, we aim in this work to verify the feasibility of using a Nonnegative Tensor Factorization (NTF) to blind extract neutron component from mixture signals recorded at the output of fission chamber (WL-7657). This last have been simulated through the Geant4 linked to Garfield++ using a 252Cf neutron source. To achieve our objective of obtaining the best possible neutron-gamma discrimination, we have applied the two different NTF algorithms, which have been found to be the best methods that allow us to analyse this kind of nuclear data.
BLIND EXTRACTION OF AN EXOPLANETARY SPECTRUM THROUGH INDEPENDENT COMPONENT ANALYSIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waldmann, I. P.; Tinetti, G.; Hollis, M. D. J.
2013-03-20
Blind-source separation techniques are used to extract the transmission spectrum of the hot-Jupiter HD189733b recorded by the Hubble/NICMOS instrument. Such a 'blind' analysis of the data is based on the concept of independent component analysis. The detrending of Hubble/NICMOS data using the sole assumption that nongaussian systematic noise is statistically independent from the desired light-curve signals is presented. By not assuming any prior or auxiliary information but the data themselves, it is shown that spectroscopic errors only about 10%-30% larger than parametric methods can be obtained for 11 spectral bins with bin sizes of {approx}0.09 {mu}m. This represents a reasonablemore » trade-off between a higher degree of objectivity for the non-parametric methods and smaller standard errors for the parametric de-trending. Results are discussed in light of previous analyses published in the literature. The fact that three very different analysis techniques yield comparable spectra is a strong indication of the stability of these results.« less
Single-trial event-related potential extraction through one-unit ICA-with-reference
NASA Astrophysics Data System (ADS)
Lih Lee, Wee; Tan, Tele; Falkmer, Torbjörn; Leung, Yee Hong
2016-12-01
Objective. In recent years, ICA has been one of the more popular methods for extracting event-related potential (ERP) at the single-trial level. It is a blind source separation technique that allows the extraction of an ERP without making strong assumptions on the temporal and spatial characteristics of an ERP. However, the problem with traditional ICA is that the extraction is not direct and is time-consuming due to the need for source selection processing. In this paper, the application of an one-unit ICA-with-Reference (ICA-R), a constrained ICA method, is proposed. Approach. In cases where the time-region of the desired ERP is known a priori, this time information is utilized to generate a reference signal, which is then used for guiding the one-unit ICA-R to extract the source signal of the desired ERP directly. Main results. Our results showed that, as compared to traditional ICA, ICA-R is a more effective method for analysing ERP because it avoids manual source selection and it requires less computation thus resulting in faster ERP extraction. Significance. In addition to that, since the method is automated, it reduces the risks of any subjective bias in the ERP analysis. It is also a potential tool for extracting the ERP in online application.
Single-trial event-related potential extraction through one-unit ICA-with-reference.
Lee, Wee Lih; Tan, Tele; Falkmer, Torbjörn; Leung, Yee Hong
2016-12-01
In recent years, ICA has been one of the more popular methods for extracting event-related potential (ERP) at the single-trial level. It is a blind source separation technique that allows the extraction of an ERP without making strong assumptions on the temporal and spatial characteristics of an ERP. However, the problem with traditional ICA is that the extraction is not direct and is time-consuming due to the need for source selection processing. In this paper, the application of an one-unit ICA-with-Reference (ICA-R), a constrained ICA method, is proposed. In cases where the time-region of the desired ERP is known a priori, this time information is utilized to generate a reference signal, which is then used for guiding the one-unit ICA-R to extract the source signal of the desired ERP directly. Our results showed that, as compared to traditional ICA, ICA-R is a more effective method for analysing ERP because it avoids manual source selection and it requires less computation thus resulting in faster ERP extraction. In addition to that, since the method is automated, it reduces the risks of any subjective bias in the ERP analysis. It is also a potential tool for extracting the ERP in online application.
Morton, Kayce; Knight, Katelin; Kalman, Douglas; Hewlings, Susan
2018-04-16
Coffee is a primary dietary source of the chlorogenic acids (CGAs) of phenolic compounds. Coffee contains caffeine and other phytonutrients, including CGAs. Caffeine on its own has been well characterized and descried pharmacokinetically in the literature, less so for CGAs. The purpose of this double-blind crossover study was to determine the comparative pharmacokinetics of CGAs with caffeine (natural extract) with synthetic caffeine (US Pharmacopeia [USP] standard). Sixteen healthy male subjects were randomly assigned to take 1 dose of product 1, 60 mg of botanically sourced caffeine from 480 mg of green coffee bean extract, or product 2, 60 mg of synthetic USP caffeine, with 5 days between. Blood analysis was done to determine the levels of CGA compounds, more specifically 3-, 4-, and 5-caffeoylquinic acid (CQA), and serum caffeine. The natural caffeine extract exhibited mean peak concentrations (C max ) of 3-CQA (11.4 ng/mL), 4-CQA (6.84 ng/mL), and 5-CQA (7.20 ng/mL). The mean systemic 4-hour exposure (AUC 0-4 h ) was 3-CQA (27.3 ng·h/mL), 4-CQA (16.1 ng·h/mL), and 5-CQA (15.7 ng·h/mL). The median t max was 3-CQA (1.00 hour), 4-CQA (1.00 hour), and 5-CQA (1.50 hours). The t max of caffeine was 0.75 hours (natural extract) and 0.63 hours (synthetic caffeine). C max and AUC 0-4 h of serum caffeine were statistically equivalent between products. The geometric least-squares mean ratios (GMRs) of C max and AUC 0-4 h of caffeine were 97.77% (natural extract) and 98.33% (synthetic caffeine). It would appear that CGA compounds from the natural caffeine extract are bioavailable, and 3-CGA may be the compound most absorbed. In addition, caffeine sourced from natural extract versus synthetic were statistically similar for pharmacokinetic parameters. There were no adverse events or safety concerns. © 2018 The Authors. Clinical Pharmacology in Drug Development Published by Wiley Periodicals, Inc. on behalf of The American College of Clinical Pharmacology.
Blind source separation of ex-vivo aorta tissue multispectral images
Galeano, July; Perez, Sandra; Montoya, Yonatan; Botina, Deivid; Garzón, Johnson
2015-01-01
Blind Source Separation methods (BSS) aim for the decomposition of a given signal in its main components or source signals. Those techniques have been widely used in the literature for the analysis of biomedical images, in order to extract the main components of an organ or tissue under study. The analysis of skin images for the extraction of melanin and hemoglobin is an example of the use of BSS. This paper presents a proof of concept of the use of source separation of ex-vivo aorta tissue multispectral Images. The images are acquired with an interference filter-based imaging system. The images are processed by means of two algorithms: Independent Components analysis and Non-negative Matrix Factorization. In both cases, it is possible to obtain maps that quantify the concentration of the main chromophores present in aortic tissue. Also, the algorithms allow for spectral absorbance of the main tissue components. Those spectral signatures were compared against the theoretical ones by using correlation coefficients. Those coefficients report values close to 0.9, which is a good estimator of the method’s performance. Also, correlation coefficients lead to the identification of the concentration maps according to the evaluated chromophore. The results suggest that Multi/hyper-spectral systems together with image processing techniques is a potential tool for the analysis of cardiovascular tissue. PMID:26137366
Escudero, Javier; Hornero, Roberto; Abásolo, Daniel; Fernández, Alberto; Poza, Jesús
2007-01-01
The aim of this study was to improve the diagnosis of Alzheimer's disease (AD) patients applying a blind source separation (BSS) and component selection procedure to their magnetoencephalogram (MEG) recordings. MEGs from 18 AD patients and 18 control subjects were decomposed with the algorithm for multiple unknown signals extraction. MEG channels and components were characterized by their mean frequency, spectral entropy, approximate entropy, and Lempel-Ziv complexity. Using Student's t-test, the components which accounted for the most significant differences between groups were selected. Then, these relevant components were used to partially reconstruct the MEG channels. By means of a linear discriminant analysis, we found that the BSS-preprocessed MEGs classified the subjects with an accuracy of 80.6%, whereas 72.2% accuracy was obtained without the BSS and component selection procedure.
Developing a system for blind acoustic source localization and separation
NASA Astrophysics Data System (ADS)
Kulkarni, Raghavendra
This dissertation presents innovate methodologies for locating, extracting, and separating multiple incoherent sound sources in three-dimensional (3D) space; and applications of the time reversal (TR) algorithm to pinpoint the hyper active neural activities inside the brain auditory structure that are correlated to the tinnitus pathology. Specifically, an acoustic modeling based method is developed for locating arbitrary and incoherent sound sources in 3D space in real time by using a minimal number of microphones, and the Point Source Separation (PSS) method is developed for extracting target signals from directly measured mixed signals. Combining these two approaches leads to a novel technology known as Blind Sources Localization and Separation (BSLS) that enables one to locate multiple incoherent sound signals in 3D space and separate original individual sources simultaneously, based on the directly measured mixed signals. These technologies have been validated through numerical simulations and experiments conducted in various non-ideal environments where there are non-negligible, unspecified sound reflections and reverberation as well as interferences from random background noise. Another innovation presented in this dissertation is concerned with applications of the TR algorithm to pinpoint the exact locations of hyper-active neurons in the brain auditory structure that are directly correlated to the tinnitus perception. Benchmark tests conducted on normal rats have confirmed the localization results provided by the TR algorithm. Results demonstrate that the spatial resolution of this source localization can be as high as the micrometer level. This high precision localization may lead to a paradigm shift in tinnitus diagnosis, which may in turn produce a more cost-effective treatment for tinnitus than any of the existing ones.
Blind column selection protocol for two-dimensional high performance liquid chromatography.
Burns, Niki K; Andrighetto, Luke M; Conlan, Xavier A; Purcell, Stuart D; Barnett, Neil W; Denning, Jacquie; Francis, Paul S; Stevenson, Paul G
2016-07-01
The selection of two orthogonal columns for two-dimensional high performance liquid chromatography (LC×LC) separation of natural product extracts can be a labour intensive and time consuming process and in many cases is an entirely trial-and-error approach. This paper introduces a blind optimisation method for column selection of a black box of constituent components. A data processing pipeline, created in the open source application OpenMS®, was developed to map the components within the mixture of equal mass across a library of HPLC columns; LC×LC separation space utilisation was compared by measuring the fractional surface coverage, fcoverage. It was found that for a test mixture from an opium poppy (Papaver somniferum) extract, the combination of diphenyl and C18 stationary phases provided a predicted fcoverage of 0.48 and was matched with an actual usage of 0.43. OpenMS®, in conjunction with algorithms designed in house, have allowed for a significantly quicker selection of two orthogonal columns, which have been optimised for a LC×LC separation of crude extractions of plant material. Copyright © 2016 Elsevier B.V. All rights reserved.
Fetal source extraction from magnetocardiographic recordings by dependent component analysis
NASA Astrophysics Data System (ADS)
de Araujo, Draulio B.; Kardec Barros, Allan; Estombelo-Montesco, Carlos; Zhao, Hui; Roque da Silva Filho, A. C.; Baffa, Oswaldo; Wakai, Ronald; Ohnishi, Noboru
2005-10-01
Fetal magnetocardiography (fMCG) has been extensively reported in the literature as a non-invasive, prenatal technique that can be used to monitor various functions of the fetal heart. However, fMCG signals often have low signal-to-noise ratio (SNR) and are contaminated by strong interference from the mother's magnetocardiogram signal. A promising, efficient tool for extracting signals, even under low SNR conditions, is blind source separation (BSS), or independent component analysis (ICA). Herein we propose an algorithm based on a variation of ICA, where the signal of interest is extracted using a time delay obtained from an autocorrelation analysis. We model the system using autoregression, and identify the signal component of interest from the poles of the autocorrelation function. We show that the method is effective in removing the maternal signal, and is computationally efficient. We also compare our results to more established ICA methods, such as FastICA.
Krieger, D R; Kalman, D S; Feldman, S; Arnillas, L; Goldberg, D; Gisbert, O; Nader, S
2016-06-20
This double-blind crossover clinical trial randomized 12 adult males to receive 200 mg of caffeine from a green coffee extract, a guayusa leaf extract, and a synthetic control to compare their safety, absorption, and effect on neurotransmitters. The results showed no statistically significant changes in blood pressure or heart rate from baseline to 120 min postdose of each natural source compared with changes from baseline in the control (0.094 < = P < = 0.910). The ratios of C max , AUC 0-4 , and AUC 0-∞ of each natural source to the control were bioequivalent by US Food and Drug Administration standards (90% CI within 80-125%). The guayusa leaf extract stimulated a significantly lower increase in epinephrine compared with the control (+0.5 vs. +2.78 μg/gCr, P = 0.04), while the green coffee extract provoked an increase in epinephrine similar to the control (+3.21 vs. +2.78 μg/gCr, P = 0.569). Implications for future clinical research are discussed. © 2016 The Authors. Clinical and Translational Science published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.
NASA Astrophysics Data System (ADS)
Lee, Dong-Sup; Cho, Dae-Seung; Kim, Kookhyun; Jeon, Jae-Jin; Jung, Woo-Jin; Kang, Myeng-Hwan; Kim, Jae-Ho
2015-01-01
Independent Component Analysis (ICA), one of the blind source separation methods, can be applied for extracting unknown source signals only from received signals. This is accomplished by finding statistical independence of signal mixtures and has been successfully applied to myriad fields such as medical science, image processing, and numerous others. Nevertheless, there are inherent problems that have been reported when using this technique: instability and invalid ordering of separated signals, particularly when using a conventional ICA technique in vibratory source signal identification of complex structures. In this study, a simple iterative algorithm of the conventional ICA has been proposed to mitigate these problems. The proposed method to extract more stable source signals having valid order includes an iterative and reordering process of extracted mixing matrix to reconstruct finally converged source signals, referring to the magnitudes of correlation coefficients between the intermediately separated signals and the signals measured on or nearby sources. In order to review the problems of the conventional ICA technique and to validate the proposed method, numerical analyses have been carried out for a virtual response model and a 30 m class submarine model. Moreover, in order to investigate applicability of the proposed method to real problem of complex structure, an experiment has been carried out for a scaled submarine mockup. The results show that the proposed method could resolve the inherent problems of a conventional ICA technique.
Iridology: A systematic review.
Ernst, E
1999-02-01
Iridologists claim to be able to diagnose medical conditions through abnormalities of pigmentation in the iris. This technique is popular in many countries. Therefore it is relevant to ask whether it is valid. To systematically review all interpretable tests of the validity of iridology as a diagnostic tool. DATA SOURCE AND EXTRACTION: Three independent literature searches were performed to identify all blinded tests. Data were extracted in a predefined, standardized fashion. Four case control studies were found. The majority of these investigations suggests that iridology is not a valid diagnostic method. The validity of iridology as a diagnostic tool is not supported by scientific evaluations. Patients and therapists should be discouraged from using this method.
Real-time Adaptive EEG Source Separation using Online Recursive Independent Component Analysis
Hsu, Sheng-Hsiou; Mullen, Tim; Jung, Tzyy-Ping; Cauwenberghs, Gert
2016-01-01
Independent Component Analysis (ICA) has been widely applied to electroencephalographic (EEG) biosignal processing and brain-computer interfaces. The practical use of ICA, however, is limited by its computational complexity, data requirements for convergence, and assumption of data stationarity, especially for high-density data. Here we study and validate an optimized online recursive ICA algorithm (ORICA) with online recursive least squares (RLS) whitening for blind source separation of high-density EEG data, which offers instantaneous incremental convergence upon presentation of new data. Empirical results of this study demonstrate the algorithm's: (a) suitability for accurate and efficient source identification in high-density (64-channel) realistically-simulated EEG data; (b) capability to detect and adapt to non-stationarity in 64-ch simulated EEG data; and (c) utility for rapidly extracting principal brain and artifact sources in real 61-channel EEG data recorded by a dry and wearable EEG system in a cognitive experiment. ORICA was implemented as functions in BCILAB and EEGLAB and was integrated in an open-source Real-time EEG Source-mapping Toolbox (REST), supporting applications in ICA-based online artifact rejection, feature extraction for real-time biosignal monitoring in clinical environments, and adaptable classifications in brain-computer interfaces. PMID:26685257
Tecchio, Franca; Porcaro, Camillo; Barbati, Giulia; Zappasodi, Filippo
2007-01-01
A brain–computer interface (BCI) can be defined as any system that can track the person's intent which is embedded in his/her brain activity and, from it alone, translate the intention into commands of a computer. Among the brain signal monitoring systems best suited for this challenging task, electroencephalography (EEG) and magnetoencephalography (MEG) are the most realistic, since both are non-invasive, EEG is portable and MEG could provide more specific information that could be later exploited also through EEG signals. The first two BCI steps require set up of the appropriate experimental protocol while recording the brain signal and then to extract interesting features from the recorded cerebral activity. To provide information useful in these BCI stages, our aim is to provide an overview of a new procedure we recently developed, named functional source separation (FSS). As it comes from the blind source separation algorithms, it exploits the most valuable information provided by the electrophysiological techniques, i.e. the waveform signal properties, remaining blind to the biophysical nature of the signal sources. FSS returns the single trial source activity, estimates the time course of a neuronal pool along different experimental states on the basis of a specific functional requirement in a specific time period, and uses the simulated annealing as the optimization procedure allowing the exploit of functional constraints non-differentiable. Moreover, a minor section is included, devoted to information acquired by MEG in stroke patients, to guide BCI applications aiming at sustaining motor behaviour in these patients. Relevant BCI features – spatial and time-frequency properties – are in fact altered by a stroke in the regions devoted to hand control. Moreover, a method to investigate the relationship between sensory and motor hand cortical network activities is described, providing information useful to develop BCI feedback control systems. This review provides a description of the FSS technique, a promising tool for the BCI community for online electrophysiological feature extraction, and offers interesting information to develop BCI applications to sustain hand control in stroke patients. PMID:17331989
Non-contact cardiac pulse rate estimation based on web-camera
NASA Astrophysics Data System (ADS)
Wang, Yingzhi; Han, Tailin
2015-12-01
In this paper, we introduce a new methodology of non-contact cardiac pulse rate estimation based on the imaging Photoplethysmography (iPPG) and blind source separation. This novel's approach can be applied to color video recordings of the human face and is based on automatic face tracking along with blind source separation of the color channels into RGB three-channel component. First of all, we should do some pre-processings of the data which can be got from color video such as normalization and sphering. We can use spectrum analysis to estimate the cardiac pulse rate by Independent Component Analysis (ICA) and JADE algorithm. With Bland-Altman and correlation analysis, we compared the cardiac pulse rate extracted from videos recorded by a basic webcam to a Commercial pulse oximetry sensors and achieved high accuracy and correlation. Root mean square error for the estimated results is 2.06bpm, which indicates that the algorithm can realize the non-contact measurements of cardiac pulse rate.
Blind source separation in retinal videos
NASA Astrophysics Data System (ADS)
Barriga, Eduardo S.; Truitt, Paul W.; Pattichis, Marios S.; Tüso, Dan; Kwon, Young H.; Kardon, Randy H.; Soliz, Peter
2003-05-01
An optical imaging device of retina function (OID-RF) has been developed to measure changes in blood oxygen saturation due to neural activity resulting from visual stimulation of the photoreceptors in the human retina. The video data that are collected represent a mixture of the functional signal in response to the retinal activation and other signals from undetermined physiological activity. Measured changes in reflectance in response to the visual stimulus are on the order of 0.1% to 1.0% of the total reflected intensity level which makes the functional signal difficult to detect by standard methods since it is masked by the other signals that are present. In this paper, we apply principal component analysis (PCA), blind source separation (BSS), using Extended Spatial Decorrelation (ESD) and independent component analysis (ICA) using the Fast-ICA algorithm to extract the functional signal from the retinal videos. The results revealed that the functional signal in a stimulated retina can be detected through the application of some of these techniques.
NASA Astrophysics Data System (ADS)
Dong, Shaojiang; Sun, Dihua; Xu, Xiangyang; Tang, Baoping
2017-06-01
Aiming at the problem that it is difficult to extract the feature information from the space bearing vibration signal because of different noise, for example the running trend information, high-frequency noise and especially the existence of lot of power line interference (50Hz) and its octave ingredients of the running space simulated equipment in the ground. This article proposed a combination method to eliminate them. Firstly, the EMD is used to remove the running trend item information of the signal, the running trend that affect the signal processing accuracy is eliminated. Then the morphological filter is used to eliminate high-frequency noise. Finally, the components and characteristics of the power line interference are researched, based on the characteristics of the interference, the revised blind source separation model is used to remove the power line interferences. Through analysis of simulation and practical application, results suggest that the proposed method can effectively eliminate those noise.
An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms.
Andreotti, Fernando; Behar, Joachim; Zaunseder, Sebastian; Oster, Julien; Clifford, Gari D
2016-05-01
Over the past decades, many studies have been published on the extraction of non-invasive foetal electrocardiogram (NI-FECG) from abdominal recordings. Most of these contributions claim to obtain excellent results in detecting foetal QRS (FQRS) complexes in terms of location. A small subset of authors have investigated the extraction of morphological features from the NI-FECG. However, due to the shortage of available public databases, the large variety of performance measures employed and the lack of open-source reference algorithms, most contributions cannot be meaningfully assessed. This article attempts to address these issues by presenting a standardised methodology for stress testing NI-FECG algorithms, including absolute data, as well as extraction and evaluation routines. To that end, a large database of realistic artificial signals was created, totaling 145.8 h of multichannel data and over one million FQRS complexes. An important characteristic of this dataset is the inclusion of several non-stationary events (e.g. foetal movements, uterine contractions and heart rate fluctuations) that are critical for evaluating extraction routines. To demonstrate our testing methodology, three classes of NI-FECG extraction algorithms were evaluated: blind source separation (BSS), template subtraction (TS) and adaptive methods (AM). Experiments were conducted to benchmark the performance of eight NI-FECG extraction algorithms on the artificial database focusing on: FQRS detection and morphological analysis (foetal QT and T/QRS ratio). The overall median FQRS detection accuracies (i.e. considering all non-stationary events) for the best performing methods in each group were 99.9% for BSS, 97.9% for AM and 96.0% for TS. Both FQRS detections and morphological parameters were shown to heavily depend on the extraction techniques and signal-to-noise ratio. Particularly, it is shown that their evaluation in the source domain, obtained after using a BSS technique, should be avoided. Data, extraction algorithms and evaluation routines were released as part of the fecgsyn toolbox on Physionet under an GNU GPL open-source license. This contribution provides a standard framework for benchmarking and regulatory testing of NI-FECG extraction algorithms.
Detector-device-independent quantum secret sharing with source flaws.
Yang, Xiuqing; Wei, Kejin; Ma, Haiqiang; Liu, Hongwei; Yin, Zhenqiang; Cao, Zhu; Wu, Lingan
2018-04-10
Measurement-device-independent entanglement witness (MDI-EW) plays an important role for detecting entanglement with untrusted measurement device. We present a double blinding-attack on a quantum secret sharing (QSS) protocol based on GHZ state. Using the MDI-EW method, we propose a QSS protocol against all detector side-channels. We allow source flaws in practical QSS system, so that Charlie can securely distribute a key between the two agents Alice and Bob over long distances. Our protocol provides condition on the extracted key rate for the secret against both external eavesdropper and arbitrary dishonest participants. A tight bound for collective attacks can provide good bounds on the practical QSS with source flaws. Then we show through numerical simulations that using single-photon source a secure QSS over 136 km can be achieved.
SLO blind data set inversion and classification using physically complete models
NASA Astrophysics Data System (ADS)
Shamatava, I.; Shubitidze, F.; Fernández, J. P.; Barrowes, B. E.; O'Neill, K.; Grzegorczyk, T. M.; Bijamov, A.
2010-04-01
Discrimination studies carried out on TEMTADS and Metal Mapper blind data sets collected at the San Luis Obispo UXO site are presented. The data sets included four types of targets of interest: 2.36" rockets, 60-mm mortar shells, 81-mm projectiles, and 4.2" mortar items. The total parameterized normalized magnetic source (NSMS) amplitudes were used to discriminate TOI from metallic clutter and among the different hazardous UXO. First, in object's frame coordinate, the total NSMS were determined for each TOI along three orthogonal axes from the training data provided by the Strategic Environmental Research and Development Program (SERDP) along with the referred blind data sets. Then the inverted total NSMS were used to extract the time-decay classification features. Once our inversion and classification algorithms were tested on the calibration data sets then we applied the same procedure to all blind data sets. The combined NSMS and differential evolution algorithm is utilized for determine the NSMS strengths for each cell. The obtained total NSMS time-decay curves were used to extract the discrimination features and perform classification using the training data as reference. In addition, for cross validation, the inverted locations and orientations from NSMS-DE algorithm were compared against the inverted data that obtained via the magnetic field, vector and scalar potentials (HAP) method and the combined dipole and Gauss-Newton approach technique. We examined the entire time decay history of the total NSMS case-by-case for classification purposes. Also, we use different multi-class statistical classification algorithms for separating the dangerous objects from non hazardous items. The inverted targets were ranked by target ID and submitted to SERDP for independent scoring. The independent scoring results are presented.
Underwater Acoustic Source Localisation Among Blind and Sighted Scuba Divers: Comparative study.
Cambi, Jacopo; Livi, Ludovica; Livi, Walter
2017-05-01
Many blind individuals demonstrate enhanced auditory spatial discrimination or localisation of sound sources in comparison to sighted subjects. However, this hypothesis has not yet been confirmed with regards to underwater spatial localisation. This study therefore aimed to investigate underwater acoustic source localisation among blind and sighted scuba divers. This study took place between February and June 2015 in Elba, Italy, and involved two experimental groups of divers with either acquired (n = 20) or congenital (n = 10) blindness and a control group of 30 sighted divers. Each subject took part in five attempts at an under-water acoustic source localisation task, in which the divers were requested to swim to the source of a sound originating from one of 24 potential locations. The control group had their sight obscured during the task. The congenitally blind divers demonstrated significantly better underwater sound localisation compared to the control group or those with acquired blindness ( P = 0.0007). In addition, there was a significant correlation between years of blindness and underwater sound localisation ( P <0.0001). Congenital blindness was found to positively affect the ability of a diver to recognise the source of a sound in an underwater environment. As the correct localisation of sounds underwater may help individuals to avoid imminent danger, divers should perform sound localisation tests during training sessions.
VizieR Online Data Catalog: Herschel Multi-tiered Extragalactic Survey (Oliver+, 2012)
NASA Astrophysics Data System (ADS)
Oliver, S. J.; Bock, J.; Altieri, B.; Amblard, A.; Arumugam, V.; Aussel, H.; Babbedge, T.; Beelen, A.; Bethermin, M.; Blain, A.; Boselli, A.; Bridge, C.; Brisbin, D.; Buat, V.; Burgarella, D.; Castro-Rodriguez, N.; Cava, A.; Chanial, P.; Cirasuolo, M.; Clements, D. L.; Conley, A.; Conversi, L.; Cooray, A.; Dowell, C. D.; Dubois, E. N.; Dwek, E.; Dye, S.; Eales, S.; Elbaz, D.; Farrah, D.; Feltre, A.; Ferrero, P.; Fiolet, N.; Fox, M.; Franceschini, A.; Gear, W.; Giovannoli, E.; Glenn, J.; Gong, Y.; Gonzalez Solares, E. A.; Griffin, M.; Halpern, M.; Harwit, M.; Hatziminaoglou, E.; Heinis, S.; Hurley, P.; Hwang, H. S.; Hyde, A.; Ibar, E.; Ilbert, O.; Isaak, K.; Ivison, R. J.; Lagache, G.; Le Floc'h, E.; Levenson, L.; Faro, B. L.; Lu, N.; Madden, S.; Maffei, B.; Magdis, G.; Mainetti, G.; Marchetti, L.; Marsden, G.; Marshall, J.; Mortier, A. M. J.; Nguyen, H. T.; O'Halloran, B.; Omont, A.; Page, M. J.; Panuzzo, P.; Papageorgiou, A.; Patel, H.; Pearson, C. P.; Perez-Fournon, I.; Pohlen, M.; Rawlings, J. I.; Raymond, G.; Rigopoulou, D.; Riguccini, L.; Rizzo, D.; Rodighier!, O. G.; Ros Eboom, I. G.; Rowan-Robinson, M.; Sanchez Portal, M.; Schulz, B.; Scott, D.; Seymour, N.; Shupe, D. L.; Smith, A. J.; Stevens, J. A.; Symeonidis, M.; Trichas, M.; Tugwell, K. E.; Vaccari, M.; Valtchanov, I.; Vieira, J. D.; Viero, M.; Vigroux, L.; Wang, L.; Ward, R.; Wardlow, J.; Wright, G.; Xu, C. K.; Zemcov, M.
2017-03-01
SPIRE maps (250, 350 and 500 microns) and PACS maps (100 and 160 microns) covering an area of more than 385 square degrees in the sky resulting from observations taken as part of HerMES (KPGTsoliver1), a Herschel Key Project whose main objective was to chart the formation and evolution of infrared galaxies throughout cosmic history, measuring the bolometric emission of infrared galaxies and their clustering properties. The associated catalogues extracted from these maps include over 1,200,000 entries representing over 340,000 galaxies. They consist of 'blind extraction' catalogues containing photometric information derived directly from these maps, 'band merged' catalogues extracted at SPIRE 250 micron positions plus 'cross-identification' catalogues based on prior Spitzer MIPS 24 micron source positions. The latest data releases contain also information derived from the complementary Herschel programmes HeLMS (GT2mviero1) and HeRS (OT2mviero2). (4 data files).
Underwater Acoustic Source Localisation Among Blind and Sighted Scuba Divers
Cambi, Jacopo; Livi, Ludovica; Livi, Walter
2017-01-01
Objectives Many blind individuals demonstrate enhanced auditory spatial discrimination or localisation of sound sources in comparison to sighted subjects. However, this hypothesis has not yet been confirmed with regards to underwater spatial localisation. This study therefore aimed to investigate underwater acoustic source localisation among blind and sighted scuba divers. Methods This study took place between February and June 2015 in Elba, Italy, and involved two experimental groups of divers with either acquired (n = 20) or congenital (n = 10) blindness and a control group of 30 sighted divers. Each subject took part in five attempts at an under-water acoustic source localisation task, in which the divers were requested to swim to the source of a sound originating from one of 24 potential locations. The control group had their sight obscured during the task. Results The congenitally blind divers demonstrated significantly better underwater sound localisation compared to the control group or those with acquired blindness (P = 0.0007). In addition, there was a significant correlation between years of blindness and underwater sound localisation (P <0.0001). Conclusion Congenital blindness was found to positively affect the ability of a diver to recognise the source of a sound in an underwater environment. As the correct localisation of sounds underwater may help individuals to avoid imminent danger, divers should perform sound localisation tests during training sessions. PMID:28690888
A novel blinding digital watermark algorithm based on lab color space
NASA Astrophysics Data System (ADS)
Dong, Bing-feng; Qiu, Yun-jie; Lu, Hong-tao
2010-02-01
It is necessary for blinding digital image watermark algorithm to extract watermark information without any extra information except the watermarked image itself. But most of the current blinding watermark algorithms have the same disadvantage: besides the watermarked image, they also need the size and other information about the original image when extracting the watermark. This paper presents an innovative blinding color image watermark algorithm based on Lab color space, which does not have the disadvantages mentioned above. This algorithm first marks the watermark region size and position through embedding some regular blocks called anchor points in image spatial domain, and then embeds the watermark into the image. In doing so, the watermark information can be easily extracted after doing cropping and scale change to the image. Experimental results show that the algorithm is particularly robust against the color adjusting and geometry transformation. This algorithm has already been used in a copyright protecting project and works very well.
Powerline noise elimination in biomedical signals via blind source separation and wavelet analysis.
Akwei-Sekyere, Samuel
2015-01-01
The distortion of biomedical signals by powerline noise from recording biomedical devices has the potential to reduce the quality and convolute the interpretations of the data. Usually, powerline noise in biomedical recordings are extinguished via band-stop filters. However, due to the instability of biomedical signals, the distribution of signals filtered out may not be centered at 50/60 Hz. As a result, self-correction methods are needed to optimize the performance of these filters. Since powerline noise is additive in nature, it is intuitive to model powerline noise in a raw recording and subtract it from the raw data in order to obtain a relatively clean signal. This paper proposes a method that utilizes this approach by decomposing the recorded signal and extracting powerline noise via blind source separation and wavelet analysis. The performance of this algorithm was compared with that of a 4th order band-stop Butterworth filter, empirical mode decomposition, independent component analysis and, a combination of empirical mode decomposition with independent component analysis. The proposed method was able to expel sinusoidal signals within powerline noise frequency range with higher fidelity in comparison with the mentioned techniques, especially at low signal-to-noise ratio.
Blind estimation of reverberation time
NASA Astrophysics Data System (ADS)
Ratnam, Rama; Jones, Douglas L.; Wheeler, Bruce C.; O'Brien, William D.; Lansing, Charissa R.; Feng, Albert S.
2003-11-01
The reverberation time (RT) is an important parameter for characterizing the quality of an auditory space. Sounds in reverberant environments are subject to coloration. This affects speech intelligibility and sound localization. Many state-of-the-art audio signal processing algorithms, for example in hearing-aids and telephony, are expected to have the ability to characterize the listening environment, and turn on an appropriate processing strategy accordingly. Thus, a method for characterization of room RT based on passively received microphone signals represents an important enabling technology. Current RT estimators, such as Schroeder's method, depend on a controlled sound source, and thus cannot produce an online, blind RT estimate. Here, a method for estimating RT without prior knowledge of sound sources or room geometry is presented. The diffusive tail of reverberation was modeled as an exponentially damped Gaussian white noise process. The time-constant of the decay, which provided a measure of the RT, was estimated using a maximum-likelihood procedure. The estimates were obtained continuously, and an order-statistics filter was used to extract the most likely RT from the accumulated estimates. The procedure was illustrated for connected speech. Results obtained for simulated and real room data are in good agreement with the real RT values.
NASA Astrophysics Data System (ADS)
Neuer, Marcus J.
2013-11-01
A technique for the spectral identification of strontium-90 is shown, utilising a Maximum-Likelihood deconvolution. Different deconvolution approaches are discussed and summarised. Based on the intensity distribution of the beta emission and Geant4 simulations, a combined response matrix is derived, tailored to the β- detection process in sodium iodide detectors. It includes scattering effects and attenuation by applying a base material decomposition extracted from Geant4 simulations with a CAD model for a realistic detector system. Inversion results of measurements show the agreement between deconvolution and reconstruction. A detailed investigation with additional masking sources like 40K, 226Ra and 131I shows that a contamination of strontium can be found in the presence of these nuisance sources. Identification algorithms for strontium are presented based on the derived technique. For the implementation of blind identification, an exemplary masking ratio is calculated.
Auditory spatial representations of the world are compressed in blind humans.
Kolarik, Andrew J; Pardhan, Shahina; Cirstea, Silvia; Moore, Brian C J
2017-02-01
Compared to sighted listeners, blind listeners often display enhanced auditory spatial abilities such as localization in azimuth. However, less is known about whether blind humans can accurately judge distance in extrapersonal space using auditory cues alone. Using virtualization techniques, we show that auditory spatial representations of the world beyond the peripersonal space of blind listeners are compressed compared to those for normally sighted controls. Blind participants overestimated the distance to nearby sources and underestimated the distance to remote sound sources, in both reverberant and anechoic environments, and for speech, music, and noise signals. Functions relating judged and actual virtual distance were well fitted by compressive power functions, indicating that the absence of visual information regarding the distance of sound sources may prevent accurate calibration of the distance information provided by auditory signals.
Kurtosis Approach for Nonlinear Blind Source Separation
NASA Technical Reports Server (NTRS)
Duong, Vu A.; Stubbemd, Allen R.
2005-01-01
In this paper, we introduce a new algorithm for blind source signal separation for post-nonlinear mixtures. The mixtures are assumed to be linearly mixed from unknown sources first and then distorted by memoryless nonlinear functions. The nonlinear functions are assumed to be smooth and can be approximated by polynomials. Both the coefficients of the unknown mixing matrix and the coefficients of the approximated polynomials are estimated by the gradient descent method conditional on the higher order statistical requirements. The results of simulation experiments presented in this paper demonstrate the validity and usefulness of our approach for nonlinear blind source signal separation.
Oosugi, Naoya; Kitajo, Keiichi; Hasegawa, Naomi; Nagasaka, Yasuo; Okanoya, Kazuo; Fujii, Naotaka
2017-09-01
Blind source separation (BSS) algorithms extract neural signals from electroencephalography (EEG) data. However, it is difficult to quantify source separation performance because there is no criterion to dissociate neural signals and noise in EEG signals. This study develops a method for evaluating BSS performance. The idea is neural signals in EEG can be estimated by comparison with simultaneously measured electrocorticography (ECoG). Because the ECoG electrodes cover the majority of the lateral cortical surface and should capture most of the original neural sources in the EEG signals. We measured real EEG and ECoG data and developed an algorithm for evaluating BSS performance. First, EEG signals are separated into EEG components using the BSS algorithm. Second, the EEG components are ranked using the correlation coefficients of the ECoG regression and the components are grouped into subsets based on their ranks. Third, canonical correlation analysis estimates how much information is shared between the subsets of the EEG components and the ECoG signals. We used our algorithm to compare the performance of BSS algorithms (PCA, AMUSE, SOBI, JADE, fastICA) via the EEG and ECoG data of anesthetized nonhuman primates. The results (Best case >JADE = fastICA >AMUSE = SOBI ≥ PCA >random separation) were common to the two subjects. To encourage the further development of better BSS algorithms, our EEG and ECoG data are available on our Web site (http://neurotycho.org/) as a common testing platform. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Araújo, Iván Gómez; Sánchez, Jesús Antonio García; Andersen, Palle
2018-05-01
Transmissibility-based operational modal analysis is a recent and alternative approach used to identify the modal parameters of structures under operational conditions. This approach is advantageous compared with traditional operational modal analysis because it does not make any assumptions about the excitation spectrum (i.e., white noise with a flat spectrum). However, common methodologies do not include a procedure to extract closely spaced modes with low signal-to-noise ratios. This issue is relevant when considering that engineering structures generally have closely spaced modes and that their measured responses present high levels of noise. Therefore, to overcome these problems, a new combined method for modal parameter identification is proposed in this work. The proposed method combines blind source separation (BSS) techniques and transmissibility-based methods. Here, BSS techniques were used to recover source signals, and transmissibility-based methods were applied to estimate modal information from the recovered source signals. To achieve this combination, a new method to define a transmissibility function was proposed. The suggested transmissibility function is based on the relationship between the power spectral density (PSD) of mixed signals and the PSD of signals from a single source. The numerical responses of a truss structure with high levels of added noise and very closely spaced modes were processed using the proposed combined method to evaluate its ability to identify modal parameters in these conditions. Colored and white noise excitations were used for the numerical example. The proposed combined method was also used to evaluate the modal parameters of an experimental test on a structure containing closely spaced modes. The results showed that the proposed combined method is capable of identifying very closely spaced modes in the presence of noise and, thus, may be potentially applied to improve the identification of damping ratios.
A Markov model for blind image separation by a mean-field EM algorithm.
Tonazzini, Anna; Bedini, Luigi; Salerno, Emanuele
2006-02-01
This paper deals with blind separation of images from noisy linear mixtures with unknown coefficients, formulated as a Bayesian estimation problem. This is a flexible framework, where any kind of prior knowledge about the source images and the mixing matrix can be accounted for. In particular, we describe local correlation within the individual images through the use of Markov random field (MRF) image models. These are naturally suited to express the joint pdf of the sources in a factorized form, so that the statistical independence requirements of most independent component analysis approaches to blind source separation are retained. Our model also includes edge variables to preserve intensity discontinuities. MRF models have been proved to be very efficient in many visual reconstruction problems, such as blind image restoration, and allow separation and edge detection to be performed simultaneously. We propose an expectation-maximization algorithm with the mean field approximation to derive a procedure for estimating the mixing matrix, the sources, and their edge maps. We tested this procedure on both synthetic and real images, in the fully blind case (i.e., no prior information on mixing is exploited) and found that a source model accounting for local autocorrelation is able to increase robustness against noise, even space variant. Furthermore, when the model closely fits the source characteristics, independence is no longer a strict requirement, and cross-correlated sources can be separated, as well.
Kurtosis Approach Nonlinear Blind Source Separation
NASA Technical Reports Server (NTRS)
Duong, Vu A.; Stubbemd, Allen R.
2005-01-01
In this paper, we introduce a new algorithm for blind source signal separation for post-nonlinear mixtures. The mixtures are assumed to be linearly mixed from unknown sources first and then distorted by memoryless nonlinear functions. The nonlinear functions are assumed to be smooth and can be approximated by polynomials. Both the coefficients of the unknown mixing matrix and the coefficients of the approximated polynomials are estimated by the gradient descent method conditional on the higher order statistical requirements. The results of simulation experiments presented in this paper demonstrate the validity and usefulness of our approach for nonlinear blind source signal separation Keywords: Independent Component Analysis, Kurtosis, Higher order statistics.
Egger, S F; Huber-Spitzy, V; Alzner, E; Scholda, C; Vecsei, V P
1999-01-01
A prospective randomized double-blind clinical study was performed to investigate corneal wound healing after treatment either with an eye gel containing calf blood extract or an eye ointment containing vitamin A and dexpanthenol. A total of 54 outpatients were included in this study, all treated for corneal foreign body injury. The size of the corneal lesions was measured by planimetry on days 0, 1, and on the following days until complete epithelial healing occurred. Results showed the calf blood extract eye gel to be statistically more effective in promoting corneal wound healing, especially in patients with wound areas larger than 6 mm(2).
Constrained Null Space Component Analysis for Semiblind Source Separation Problem.
Hwang, Wen-Liang; Lu, Keng-Shih; Ho, Jinn
2018-02-01
The blind source separation (BSS) problem extracts unknown sources from observations of their unknown mixtures. A current trend in BSS is the semiblind approach, which incorporates prior information on sources or how the sources are mixed. The constrained independent component analysis (ICA) approach has been studied to impose constraints on the famous ICA framework. We introduced an alternative approach based on the null space component (NCA) framework and referred to the approach as the c-NCA approach. We also presented the c-NCA algorithm that uses signal-dependent semidefinite operators, which is a bilinear mapping, as signatures for operator design in the c-NCA approach. Theoretically, we showed that the source estimation of the c-NCA algorithm converges with a convergence rate dependent on the decay of the sequence, obtained by applying the estimated operators on corresponding sources. The c-NCA can be formulated as a deterministic constrained optimization method, and thus, it can take advantage of solvers developed in optimization society for solving the BSS problem. As examples, we demonstrated electroencephalogram interference rejection problems can be solved by the c-NCA with proximal splitting algorithms by incorporating a sparsity-enforcing separation model and considering the case when reference signals are available.
Silva, Rogers F.; Plis, Sergey M.; Sui, Jing; Pattichis, Marios S.; Adalı, Tülay; Calhoun, Vince D.
2016-01-01
In the past decade, numerous advances in the study of the human brain were fostered by successful applications of blind source separation (BSS) methods to a wide range of imaging modalities. The main focus has been on extracting “networks” represented as the underlying latent sources. While the broad success in learning latent representations from multiple datasets has promoted the wide presence of BSS in modern neuroscience, it also introduced a wide variety of objective functions, underlying graphical structures, and parameter constraints for each method. Such diversity, combined with a host of datatype-specific know-how, can cause a sense of disorder and confusion, hampering a practitioner’s judgment and impeding further development. We organize the diverse landscape of BSS models by exposing its key features and combining them to establish a novel unifying view of the area. In the process, we unveil important connections among models according to their properties and subspace structures. Consequently, a high-level descriptive structure is exposed, ultimately helping practitioners select the right model for their applications. Equipped with that knowledge, we review the current state of BSS applications to neuroimaging. The gained insight into model connections elicits a broader sense of generalization, highlighting several directions for model development. In light of that, we discuss emerging multi-dataset multidimensional (MDM) models and summarize their benefits for the study of the healthy brain and disease-related changes. PMID:28461840
Lopatkin, N; Sivkov, A; Walther, C; Schläfke, S; Medvedev, A; Avdeichuk, J; Golubev, G; Melnik, K; Elenberger, N; Engelmann, U
2005-06-01
The efficacy and tolerability of a fixed combination of 160 mg sabal fruit extract WS 1473 and 120 mg urtica root extract WS 1031 per capsule (PRO 160/120) was investigated in elderly, male patients suffering from lower urinary tract symptoms (LUTS) caused by benign prostatic hyperplasia in a prospective multicenter trial. A total of 257 patients (129 and 128, respectively) were randomized to treatment with PRO 160/120 or placebo (127 and 126 were evaluable for efficacy). Following a single-blind placebo run-in phase of 2 weeks, the patients received 2 x 1 capsule/day of the study medication under double-blind conditions over a period of 24 weeks. Double-blind treatment was followed by an open control period of 24 weeks during which all patients were administered PRO 160/120. Outcome measures for treatment efficacy included the assessment of the patients' LUTS by means of the I-PSS self-rating questionnaire and a quality of life index as well as uroflow and sonographic parameters. Using the International Prostate Symptom Score (I-PSS), patients treated with PRO 160/120 exhibited a substantially higher total score reduction after 24 weeks of double-blind treatment than patients of the placebo group (6 points vs 4 points; P=0.003, one tailed) with a tendency in the same direction after 16 weeks. This applied to obstructive as well as to irritative symptoms, and to patients with moderate or severe symptoms at baseline. Patients randomized to placebo showed a marked improvement in LUTS (as measured by the I-PSS) after being switched to PRO 160/120 during the control period (P=0.01, one tailed, in comparison to those who had been treated with PRO 160/120 in the double-blind phase). The tolerability of PRO 160/120 was comparable to the placebo. In conclusion, PRO 160/120 was clearly superior to the placebo for the amelioration of LUTS as measured by the I-PSS. PRO 160/120 is advantageous in obstructive and irritative urinary symptoms and in patients with moderate and severe symptoms. The tolerability of the herbal extract was excellent.
Audio signal analysis for tool wear monitoring in sheet metal stamping
NASA Astrophysics Data System (ADS)
Ubhayaratne, Indivarie; Pereira, Michael P.; Xiang, Yong; Rolfe, Bernard F.
2017-02-01
Stamping tool wear can significantly degrade product quality, and hence, online tool condition monitoring is a timely need in many manufacturing industries. Even though a large amount of research has been conducted employing different sensor signals, there is still an unmet demand for a low-cost easy to set up condition monitoring system. Audio signal analysis is a simple method that has the potential to meet this demand, but has not been previously used for stamping process monitoring. Hence, this paper studies the existence and the significance of the correlation between emitted sound signals and the wear state of sheet metal stamping tools. The corrupting sources generated by the tooling of the stamping press and surrounding machinery have higher amplitudes compared to that of the sound emitted by the stamping operation itself. Therefore, a newly developed semi-blind signal extraction technique was employed as a pre-processing technique to mitigate the contribution of these corrupting sources. The spectral analysis results of the raw and extracted signals demonstrate a significant qualitative relationship between wear progression and the emitted sound signature. This study lays the basis for employing low-cost audio signal analysis in the development of a real-time industrial tool condition monitoring system.
NASA Astrophysics Data System (ADS)
Chiarucci, Simone; Wijnholds, Stefan J.
2018-02-01
Blind calibration, i.e. calibration without a priori knowledge of the source model, is robust to the presence of unknown sources such as transient phenomena or (low-power) broad-band radio frequency interference that escaped detection. In this paper, we present a novel method for blind calibration of a radio interferometric array assuming that the observed field only contains a small number of discrete point sources. We show the huge computational advantage over previous blind calibration methods and we assess its statistical efficiency and robustness to noise and the quality of the initial estimate. We demonstrate the method on actual data from a Low-Frequency Array low-band antenna station showing that our blind calibration is able to recover the same gain solutions as the regular calibration approach, as expected from theory and simulations. We also discuss the implications of our findings for the robustness of regular self-calibration to poor starting models.
SENSITIVITY OF BLIND PULSAR SEARCHES WITH THE FERMI LARGE AREA TELESCOPE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dormody, M.; Johnson, R. P.; Atwood, W. B.
2011-12-01
We quantitatively establish the sensitivity to the detection of young to middle-aged, isolated, gamma-ray pulsars through blind searches of Fermi Large Area Telescope (LAT) data using a Monte Carlo simulation. We detail a sensitivity study of the time-differencing blind search code used to discover gamma-ray pulsars in the first year of observations. We simulate 10,000 pulsars across a broad parameter space and distribute them across the sky. We replicate the analysis in the Fermi LAT First Source Catalog to localize the sources, and the blind search analysis to find the pulsars. We analyze the results and discuss the effect ofmore » positional error and spin frequency on gamma-ray pulsar detections. Finally, we construct a formula to determine the sensitivity of the blind search and present a sensitivity map assuming a standard set of pulsar parameters. The results of this study can be applied to population studies and are useful in characterizing unidentified LAT sources.« less
Single-channel mixed signal blind source separation algorithm based on multiple ICA processing
NASA Astrophysics Data System (ADS)
Cheng, Xiefeng; Li, Ji
2017-01-01
Take separating the fetal heart sound signal from the mixed signal that get from the electronic stethoscope as the research background, the paper puts forward a single-channel mixed signal blind source separation algorithm based on multiple ICA processing. Firstly, according to the empirical mode decomposition (EMD), the single-channel mixed signal get multiple orthogonal signal components which are processed by ICA. The multiple independent signal components are called independent sub component of the mixed signal. Then by combining with the multiple independent sub component into single-channel mixed signal, the single-channel signal is expanded to multipath signals, which turns the under-determined blind source separation problem into a well-posed blind source separation problem. Further, the estimate signal of source signal is get by doing the ICA processing. Finally, if the separation effect is not very ideal, combined with the last time's separation effect to the single-channel mixed signal, and keep doing the ICA processing for more times until the desired estimated signal of source signal is get. The simulation results show that the algorithm has good separation effect for the single-channel mixed physiological signals.
Howell, Amy; Souza, Dan; Roller, Marc; Fromentin, Emilie
2015-07-01
Research suggests that cranberry (Vaccinium macrocarpon) helps maintain urinary tract health. Bacterial adhesion to the uroepithelium is the initial step in the progression to development of a urinary tract infection. The bacterial anti-adhesion activity of cranberry proanthocyanidins (PACs) has been demonstrated in vitro. Three different cranberry extracts were developed containing a standardized level of 36 mg of PACs. This randomized, double-blind, placebo controlled, ex vivo, acute study was designed to compare the anti-adhesion activity exhibited by human urine following consumption of three different cranberry extracts on uropathogenic P-fimbriated Escherichia coli in healthy men and women. All three cranberry extracts significantly increased anti-adhesion activity in urine. from 6 to 12 hours after intake of a single dose standardized to deliver 36 mg of PACs (as measured by the BL-DMAC method), versus placebo.
ERIC Educational Resources Information Center
Schwab, Lois O.
The proceedings are composed of nine papers that discuss different aspects of the rehabilitation teacher of the blind in his effort to teach the newly blinded homemaker. The introductory paper explains briefly the way in which different sources work together toward rehabilitating the blind homemaker. The following three papers then discuss, in…
A Charrelation Matrix-Based Blind Adaptive Detector for DS-CDMA Systems
Luo, Zhongqiang; Zhu, Lidong
2015-01-01
In this paper, a blind adaptive detector is proposed for blind separation of user signals and blind estimation of spreading sequences in DS-CDMA systems. The blind separation scheme exploits a charrelation matrix for simple computation and effective extraction of information from observation signal samples. The system model of DS-CDMA signals is modeled as a blind separation framework. The unknown user information and spreading sequence of DS-CDMA systems can be estimated only from the sampled observation signals. Theoretical analysis and simulation results show that the improved performance of the proposed algorithm in comparison with the existing conventional algorithms used in DS-CDMA systems. Especially, the proposed scheme is suitable for when the number of observation samples is less and the signal to noise ratio (SNR) is low. PMID:26287209
A Charrelation Matrix-Based Blind Adaptive Detector for DS-CDMA Systems.
Luo, Zhongqiang; Zhu, Lidong
2015-08-14
In this paper, a blind adaptive detector is proposed for blind separation of user signals and blind estimation of spreading sequences in DS-CDMA systems. The blind separation scheme exploits a charrelation matrix for simple computation and effective extraction of information from observation signal samples. The system model of DS-CDMA signals is modeled as a blind separation framework. The unknown user information and spreading sequence of DS-CDMA systems can be estimated only from the sampled observation signals. Theoretical analysis and simulation results show that the improved performance of the proposed algorithm in comparison with the existing conventional algorithms used in DS-CDMA systems. Especially, the proposed scheme is suitable for when the number of observation samples is less and the signal to noise ratio (SNR) is low.
Tian, Yingli; Yang, Xiaodong; Yi, Chucai; Arditi, Aries
2013-04-01
Independent travel is a well known challenge for blind and visually impaired persons. In this paper, we propose a proof-of-concept computer vision-based wayfinding aid for blind people to independently access unfamiliar indoor environments. In order to find different rooms (e.g. an office, a lab, or a bathroom) and other building amenities (e.g. an exit or an elevator), we incorporate object detection with text recognition. First we develop a robust and efficient algorithm to detect doors, elevators, and cabinets based on their general geometric shape, by combining edges and corners. The algorithm is general enough to handle large intra-class variations of objects with different appearances among different indoor environments, as well as small inter-class differences between different objects such as doors and door-like cabinets. Next, in order to distinguish intra-class objects (e.g. an office door from a bathroom door), we extract and recognize text information associated with the detected objects. For text recognition, we first extract text regions from signs with multiple colors and possibly complex backgrounds, and then apply character localization and topological analysis to filter out background interference. The extracted text is recognized using off-the-shelf optical character recognition (OCR) software products. The object type, orientation, location, and text information are presented to the blind traveler as speech.
Tian, YingLi; Yang, Xiaodong; Yi, Chucai; Arditi, Aries
2012-01-01
Independent travel is a well known challenge for blind and visually impaired persons. In this paper, we propose a proof-of-concept computer vision-based wayfinding aid for blind people to independently access unfamiliar indoor environments. In order to find different rooms (e.g. an office, a lab, or a bathroom) and other building amenities (e.g. an exit or an elevator), we incorporate object detection with text recognition. First we develop a robust and efficient algorithm to detect doors, elevators, and cabinets based on their general geometric shape, by combining edges and corners. The algorithm is general enough to handle large intra-class variations of objects with different appearances among different indoor environments, as well as small inter-class differences between different objects such as doors and door-like cabinets. Next, in order to distinguish intra-class objects (e.g. an office door from a bathroom door), we extract and recognize text information associated with the detected objects. For text recognition, we first extract text regions from signs with multiple colors and possibly complex backgrounds, and then apply character localization and topological analysis to filter out background interference. The extracted text is recognized using off-the-shelf optical character recognition (OCR) software products. The object type, orientation, location, and text information are presented to the blind traveler as speech. PMID:23630409
Nilsson, Mats E; Schenkman, Bo N
2016-02-01
Blind people use auditory information to locate sound sources and sound-reflecting objects (echolocation). Sound source localization benefits from the hearing system's ability to suppress distracting sound reflections, whereas echolocation would benefit from "unsuppressing" these reflections. To clarify how these potentially conflicting aspects of spatial hearing interact in blind versus sighted listeners, we measured discrimination thresholds for two binaural location cues: inter-aural level differences (ILDs) and inter-aural time differences (ITDs). The ILDs or ITDs were present in single clicks, in the leading component of click pairs, or in the lagging component of click pairs, exploiting processes related to both sound source localization and echolocation. We tested 23 blind (mean age = 54 y), 23 sighted-age-matched (mean age = 54 y), and 42 sighted-young (mean age = 26 y) listeners. The results suggested greater ILD sensitivity for blind than for sighted listeners. The blind group's superiority was particularly evident for ILD-lag-click discrimination, suggesting not only enhanced ILD sensitivity in general but also increased ability to unsuppress lagging clicks. This may be related to the blind person's experience of localizing reflected sounds, for which ILDs may be more efficient than ITDs. On the ITD-discrimination tasks, the blind listeners performed better than the sighted age-matched listeners, but not better than the sighted young listeners. ITD sensitivity declines with age, and the equal performance of the blind listeners compared to a group of substantially younger listeners is consistent with the notion that blind people's experience may offset age-related decline in ITD sensitivity. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
20 CFR 416.919h - Your treating source.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Your treating source. 416.919h Section 416.919h Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED, BLIND, AND DISABLED Determining Disability and Blindness Standards for the Type of Referral and for...
Differential cataract blindness by sex in India: Evidence from two large national surveys.
Pant, Hira B; Bandyopadhyay, Souvik; John, Neena; Chandran, Anil; Gudlavalleti, Murthy Venkata S
2017-02-01
Women suffer disproportionately more from cataract blindness compared to males in low- and middle-income countries. Two large population-based surveys have been undertaken in India at an interval of 7 years and data from these surveys provided an opportunity to assess the trends in gender differentials in cataract blindness. Data were extracted from the surveys to discern sex differences in cataract blindness. Multivariate analysis was performed to adjust for confounders and their impact on gender differences in cataract blindness. Blindness was defined as presenting vision <20/400 in the better eye, and a cataract blind person was defined as a blind person where the principal cause of loss of vision was cataract. Prevalence of cataract blindness was higher in females compared to males in both surveys. The odds of cataract blindness for females did not change over time as observed in the surveys (1999-2001 and 2006-2007). Adjusted odds ratio from logistic regression analysis revealed that females continued to be at a higher risk of cataract blindness. Sex differences continued in India in relation to cataract blindness despite the gains made by the national program.
NASA Astrophysics Data System (ADS)
Yao, Jiachi; Xiang, Yang; Qian, Sichong; Li, Shengyang; Wu, Shaowei
2017-11-01
In order to separate and identify the combustion noise and the piston slap noise of a diesel engine, a noise source separation and identification method that combines a binaural sound localization method and blind source separation method is proposed. During a diesel engine noise and vibration test, because a diesel engine has many complex noise sources, a lead covering method was carried out on a diesel engine to isolate other interference noise from the No. 1-5 cylinders. Only the No. 6 cylinder parts were left bare. Two microphones that simulated the human ears were utilized to measure the radiated noise signals 1 m away from the diesel engine. First, a binaural sound localization method was adopted to separate the noise sources that are in different places. Then, for noise sources that are in the same place, a blind source separation method is utilized to further separate and identify the noise sources. Finally, a coherence function method, continuous wavelet time-frequency analysis method, and prior knowledge of the diesel engine are combined to further identify the separation results. The results show that the proposed method can effectively separate and identify the combustion noise and the piston slap noise of a diesel engine. The frequency of the combustion noise and the piston slap noise are respectively concentrated at 4350 Hz and 1988 Hz. Compared with the blind source separation method, the proposed method has superior separation and identification effects, and the separation results have fewer interference components from other noise.
Stough, Con; Downey, Luke A; Lloyd, Jenny; Silber, Beata; Redman, Stephanie; Hutchison, Chris; Wesnes, Keith; Nathan, Pradeep J
2008-12-01
While Ayurvedic medicine has touted the cognitive enhancing effects of Bacopa monniera for centuries, there is a need for double-blind placebo-controlled investigations. One hundred and seven healthy participants were recruited for this double-blind placebo-controlled independent group design investigation. Sixty-two participants completed the study with 80% treatment compliance. Neuropsychological testing using the Cognitive Drug Research cognitive assessment system was conducted at baseline and after 90 days of treatment with a special extract of Bacopa monniera (2 x 150 mg KeenMind) or placebo. The Bacopa monniera product significantly improved performance on the 'Working Memory' factor, more specifically spatial working memory accuracy. The number of false-positives recorded in the Rapid visual information processing task was also reduced for the Bacopa monniera group following the treatment period. The current study provides support for the two other published studies reporting cognitive enhancing effects in healthy humans after a 90 day administration of the Bacopa monniera extract. Further studies are required to ascertain the effective dosage range, the time required to attain therapeutic levels and the effects over a longer term of administration. (c) 2008 John Wiley & Sons, Ltd.
Tolkach, Yuri; Eminaga, Okyaz; Wötzel, Fabian; Huss, Sebastian; Bettendorf, Olaf; Eltze, Elke; Abbas, Mahmoud; Imkamp, Florian; Semjonow, Axel
2017-03-01
Fresh tissue is mandatory to perform high-quality translation studies. Several models for tissue extraction from prostatectomy specimens without guidance by frozen sections are already introduced. However, little is known about the sampling efficacy of these models, which should provide representative tissue in adequate volumes, account for multifocality and heterogeneity of tumor, not violate the routine final pathological examination, and perform quickly without frozen section-based histological control. The aim of the study was to evaluate the sampling efficacy of the existing tissue extraction models without guidance by frozen sections ("blind") and to develop an optimized model for tissue extraction. Five hundred thirty-three electronic maps of the tumor distribution in prostates from a single-center cohort of the patients subjected to radical prostatectomy were used for analysis. Six available models were evaluated in silico for their sampling efficacy. Additionally, a novel model achieving the best sampling efficacy was developed. The available models showed high efficacies for sampling "any part" from the tumor (up to 100%), but were uniformly low in efficacy to sample all tumor foci from the specimens (with the best technique sampling only 51.6% of the all tumor foci). The novel 4-level extraction model achieved a sampling efficacy of 93.1% for all tumor foci. The existing "blind" tissue extraction models from prostatectomy specimens without frozen sections control are suitable to target tumor tissues but these tissues do not represent the whole tumor. The novel 4-level model provides the highest sampling efficacy and a promising potential for integration into routine. Prostate 77: 396-405, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Antihypertensive effect of Iranian Crataegus curvisepala Lind.: a randomized, double-blind study.
Asgary, S; Naderi, G H; Sadeghi, M; Kelishadi, R; Amiri, M
2004-01-01
The aim of the present study was to investigate the potential antihypertensive effects of extracts of the flavonoid-rich Iranian flower, Crataegus curvisepala Lind., a member of the Rosaceae family. The hydroalcoholic extract of the leaves and flowers were studied in a double-blind, placebo-controlled clinical trial to determine its effects. A total of 92 men and women with primary mild hypertension, aged 40-60 years, were selected and divided randomly into two groups, receiving either hydroalcoholic extract of C. curvisepala Lind. or placebo three times daily for more than 4 months. Blood pressure (BP) was measured each month. Statistical analysis was carried out using Student's t-test. The results obtained showed a significant decrease in both systolic and diastolic BP after 3 months (p < 0.05). C. curvisepala has a time-dependent antihypertensive effect.
NASA Astrophysics Data System (ADS)
Kusyk, Janusz; Eskicioglu, Ahmet M.
2005-10-01
Digital watermarking is considered to be a major technology for the protection of multimedia data. Some of the important applications are broadcast monitoring, copyright protection, and access control. In this paper, we present a semi-blind watermarking scheme for embedding a logo in color images using the DFT domain. After computing the DFT of the luminance layer of the cover image, the magnitudes of DFT coefficients are compared, and modified. A given watermark is embedded in three frequency bands: Low, middle, and high. Our experiments show that the watermarks extracted from the lower frequencies have the best visual quality for low pass filtering, adding Gaussian noise, JPEG compression, resizing, rotation, and scaling, and the watermarks extracted from the higher frequencies have the best visual quality for cropping, intensity adjustment, histogram equalization, and gamma correction. Extractions from the fragmented and translated image are identical to extractions from the unattacked watermarked image. The collusion and rewatermarking attacks do not provide the hacker with useful tools.
Blind separation of incoherent and spatially disjoint sound sources
NASA Astrophysics Data System (ADS)
Dong, Bin; Antoni, Jérôme; Pereira, Antonio; Kellermann, Walter
2016-11-01
Blind separation of sound sources aims at reconstructing the individual sources which contribute to the overall radiation of an acoustical field. The challenge is to reach this goal using distant measurements when all sources are operating concurrently. The working assumption is usually that the sources of interest are incoherent - i.e. statistically orthogonal - so that their separation can be approached by decorrelating a set of simultaneous measurements, which amounts to diagonalizing the cross-spectral matrix. Principal Component Analysis (PCA) is traditionally used to this end. This paper reports two new findings in this context. First, a sufficient condition is established under which "virtual" sources returned by PCA coincide with true sources; it stipulates that the sources of interest should be not only incoherent but also spatially orthogonal. A particular case of this instance is met by spatially disjoint sources - i.e. with non-overlapping support sets. Second, based on this finding, a criterion that enforces both statistical and spatial orthogonality is proposed to blindly separate incoherent sound sources which radiate from disjoint domains. This criterion can be easily incorporated into acoustic imaging algorithms such as beamforming or acoustical holography to identify sound sources of different origins. The proposed methodology is validated on laboratory experiments. In particular, the separation of aeroacoustic sources is demonstrated in a wind tunnel.
Huang, Chih-Sheng; Yang, Wen-Yu; Chuang, Chun-Hsiang; Wang, Yu-Kai
2018-01-01
Electroencephalogram (EEG) signals are usually contaminated with various artifacts, such as signal associated with muscle activity, eye movement, and body motion, which have a noncerebral origin. The amplitude of such artifacts is larger than that of the electrical activity of the brain, so they mask the cortical signals of interest, resulting in biased analysis and interpretation. Several blind source separation methods have been developed to remove artifacts from the EEG recordings. However, the iterative process for measuring separation within multichannel recordings is computationally intractable. Moreover, manually excluding the artifact components requires a time-consuming offline process. This work proposes a real-time artifact removal algorithm that is based on canonical correlation analysis (CCA), feature extraction, and the Gaussian mixture model (GMM) to improve the quality of EEG signals. The CCA was used to decompose EEG signals into components followed by feature extraction to extract representative features and GMM to cluster these features into groups to recognize and remove artifacts. The feasibility of the proposed algorithm was demonstrated by effectively removing artifacts caused by blinks, head/body movement, and chewing from EEG recordings while preserving the temporal and spectral characteristics of the signals that are important to cognitive research. PMID:29599950
Ginkgo biloba Extract for Patients with Early Diabetic Nephropathy: A Systematic Review
Zhang, Lei; Mao, Wei; Guo, Xinfeng; Wu, Yifan; Li, Chuang; Lu, Zhaoyu; Su, Guobin; Li, Xiaoyan; Liu, Zhuangzhu; Guo, Rong; Jie, Xina; Wen, Zehuai; Liu, Xusheng
2013-01-01
Objectives. To evaluate the effectiveness and safety of a Ginkgo biloba extract for patients with early diabetic nephropathy. Methods. Randomised controlled trials (RCTs) conducted on adults with early diabetic nephropathy which used Gingko biloba extract were included. The major databases were searched, and manufacturers of Gingko biloba products were contacted for information on any published or unpublished studies. Two authors independently extracted the data from the included studies. Data analysis was conducted using Review Manager 5.0 software. Results. Sixteen RCTs were included. Ginkgo biloba extract decreased the urinary albumin excretion rate (UAER), fasting blood glucose (FBG), serum creatinine (SCR), and blood urea nitrogen (BUN). The extract also improved hemorheology. The methodological quality in the included studies was low. The explicit generation of the allocation sequence was described in only 6 trials. None of the included trials were confirmed to use blinding. Three studies had observed adverse events. One study using angiotensin-converting enzyme inhibitor (ACEi) reported mild cough in both groups. No serious adverse effects were reported. Conclusions. Gingko biloba extract is a valuable drug which has prospect in treating early diabetic nephropathy, especially with high UAER baseline level. The safety for early diabetic nephropathy is uncertain. Long-term, double-blinded RCTs with large sample sizes are still needed to provide stronger evidence. PMID:23533513
A Virtual Blind Cane Using a Line Laser-Based Vision System and an Inertial Measurement Unit
Dang, Quoc Khanh; Chee, Youngjoon; Pham, Duy Duong; Suh, Young Soo
2016-01-01
A virtual blind cane system for indoor application, including a camera, a line laser and an inertial measurement unit (IMU), is proposed in this paper. Working as a blind cane, the proposed system helps a blind person find the type of obstacle and the distance to it. The distance from the user to the obstacle is estimated by extracting the laser coordinate points on the obstacle, as well as tracking the system pointing angle. The paper provides a simple method to classify the obstacle’s type by analyzing the laser intersection histogram. Real experimental results are presented to show the validity and accuracy of the proposed system. PMID:26771618
Distant touch hydrodynamic imaging with an artificial lateral line.
Yang, Yingchen; Chen, Jack; Engel, Jonathan; Pandya, Saunvit; Chen, Nannan; Tucker, Craig; Coombs, Sheryl; Jones, Douglas L; Liu, Chang
2006-12-12
Nearly all underwater vehicles and surface ships today use sonar and vision for imaging and navigation. However, sonar and vision systems face various limitations, e.g., sonar blind zones, dark or murky environments, etc. Evolved over millions of years, fish use the lateral line, a distributed linear array of flow sensing organs, for underwater hydrodynamic imaging and information extraction. We demonstrate here a proof-of-concept artificial lateral line system. It enables a distant touch hydrodynamic imaging capability to critically augment sonar and vision systems. We show that the artificial lateral line can successfully perform dipole source localization and hydrodynamic wake detection. The development of the artificial lateral line is aimed at fundamentally enhancing human ability to detect, navigate, and survive in the underwater environment.
Blind Source Separation of Seismic Events with Independent Component Analysis: CTBT related exercise
NASA Astrophysics Data System (ADS)
Rozhkov, Mikhail; Kitov, Ivan
2015-04-01
Blind Source Separation (BSS) methods used in signal recovery applications are attractive for they use minimal a priori information about the signals they are dealing with. Homomorphic deconvolution and cepstrum estimation are probably the only methods used in certain extent in CTBT applications that can be attributed to the given branch of technology. However Expert Technical Analysis (ETA) conducted in CTBTO to improve the estimated values for the standard signal and event parameters according to the Protocol to the CTBT may face problems which cannot be resolved with certified CTBTO applications and may demand specific techniques not presently used. The problem to be considered within the ETA framework is the unambiguous separation of signals with close arrival times. Here, we examine two scenarios of interest: (1) separation of two almost co-located explosions conducted within fractions of seconds, and (2) extraction of explosion signals merged with wavetrains from strong earthquake. The importance of resolving the problem related to case 1 is connected with the correct explosion yield estimation. Case 2 is a well-known scenario of conducting clandestine nuclear tests. While the first case can be approached somehow with the means of cepstral methods, the second case can hardly be resolved with the conventional methods implemented at the International Data Centre, especially if the signals have close slowness and azimuth. Independent Component Analysis (in its FastICA implementation) implying non-Gaussianity of the underlying processes signal's mixture is a blind source separation method that we apply to resolve the mentioned above problems. We have tested this technique with synthetic waveforms, seismic data from DPRK explosions and mining blasts conducted within East-European platform as well as with signals from strong teleseismic events (Sumatra, April 2012 Mw=8.6, and Tohoku, March 2011 Mw=9.0 earthquakes). The data was recorded by seismic arrays of the International Monitoring System of CTBTO and by small-aperture seismic array Mikhnevo (MHVAR) operated by the Institute of Geosphere Dynamics, Russian Academy of Sciences. Our approach demonstrated a good ability of separation of seismic sources with very close origin times and locations (hundreds of meters), and/or having close arrival times (fractions of seconds), and recovering their waveforms from the mixture. Perspectives and limitations of the method are discussed.
USDA-ARS?s Scientific Manuscript database
We assessed whether a wheat bran extract containing arabino-xylan-oligosaccharide (AXOS) elicited a prebiotic effect and influenced other physiologic parameters when consumed in ready-to-eat cereal at two dose levels. This double-blind, randomized, controlled, crossover trial evaluated the effects o...
NASA Astrophysics Data System (ADS)
Sadhu, A.; Narasimhan, S.; Antoni, J.
2017-09-01
Output-only modal identification has seen significant activity in recent years, especially in large-scale structures where controlled input force generation is often difficult to achieve. This has led to the development of new system identification methods which do not require controlled input. They often work satisfactorily if they satisfy some general assumptions - not overly restrictive - regarding the stochasticity of the input. Hundreds of papers covering a wide range of applications appear every year related to the extraction of modal properties from output measurement data in more than two dozen mechanical, aerospace and civil engineering journals. In little more than a decade, concepts of blind source separation (BSS) from the field of acoustic signal processing have been adopted by several researchers and shown that they can be attractive tools to undertake output-only modal identification. Originally intended to separate distinct audio sources from a mixture of recordings, mathematical equivalence to problems in linear structural dynamics have since been firmly established. This has enabled many of the developments in the field of BSS to be modified and applied to output-only modal identification problems. This paper reviews over hundred articles related to the application of BSS and their variants to output-only modal identification. The main contribution of the paper is to present a literature review of the papers which have appeared on the subject. While a brief treatment of the basic ideas are presented where relevant, a comprehensive and critical explanation of their contents is not attempted. Specific issues related to output-only modal identification and the relative advantages and limitations of BSS methods both from theoretical and application standpoints are discussed. Gap areas requiring additional work are also summarized and the paper concludes with possible future trends in this area.
Iterative algorithm for joint zero diagonalization with application in blind source separation.
Zhang, Wei-Tao; Lou, Shun-Tian
2011-07-01
A new iterative algorithm for the nonunitary joint zero diagonalization of a set of matrices is proposed for blind source separation applications. On one hand, since the zero diagonalizer of the proposed algorithm is constructed iteratively by successive multiplications of an invertible matrix, the singular solutions that occur in the existing nonunitary iterative algorithms are naturally avoided. On the other hand, compared to the algebraic method for joint zero diagonalization, the proposed algorithm requires fewer matrices to be zero diagonalized to yield even better performance. The extension of the algorithm to the complex and nonsquare mixing cases is also addressed. Numerical simulations on both synthetic data and blind source separation using time-frequency distributions illustrate the performance of the algorithm and provide a comparison to the leading joint zero diagonalization schemes.
Zargaran, Arman; Borhani-Haghighi, Afshin; Salehi-Marzijarani, Mohammad; Faridi, Pouya; Daneshamouz, Saeid; Azadi, Amir; Sadeghpour, Hossein; Sakhteman, Amirhossein; Mohagheghzadeh, Abdolali
2018-05-28
Phytotherapy is a source of finding new remedies for migraine. Traditional chamomile oil (chamomile extraction in sesame oil) is a formulation in Persian medicine (PM) for pain relief in migraine. An oleogel preparation of reformulated traditional chamomile oil was prepared and then standardized based on chamazulene (as a marker in essential oil) and apigenin via gas chromatography (GC) and high-performance liquid chromatography (HPLC) methods, respectively. A crossover double-blind clinical trial was performed with 100 patients. Each patient took two tubes of drug and two tubes of placebo during the study. Visual analog scale (VAS) questionnaires were filled in by the patients and scores were given, ranging from 0 to 10 (based on the severity of pain) during 24 h. Other complications like nausea, vomiting, photophobia, and phonophobia were also monitored. There was 4.48 ± 0.01 μl/ml of chamazulene and 0.233 mg/g of apigenin in the preparation (by correcting the amount with extraction ratio). Thirty-eight patients in the drug-placebo and 34 patients in the placebo-drug groups (a total number of 72 patients as per protocol) completed the process in the randomized controlled trial (RCT). Adapted results from the questionnaires showed that pain, nausea, vomiting, photophobia, and phonophobia significantly (p < 0.001) decreased by using chamomile oleogel on the patients after 30 min. Results supported the efficacy of chamomile oleogel as a pain relief in migraine without aura.
Pakseresht, Siroos; Boostani, Hatam; Sayyah, Mehdi
2011-10-11
Obsessive-Compulsive Disorder (OCD) is a common neuropsychiatric condition. Many herbs with psychotropic effects exist which can have fewer side effects compared to more conventional medications. Valeriana Officinalis L. is a well-known medicinal plant with a long history of usage in the world with an effect on GABA. This plant is reported to be safe on humans. Our objective in this study was to compare the efficacy of the extract of Valeriana Officinalis L. with placebo in the treatment of OCD. The study was an 8-week pilot double-blind randomized trial. Thirty-one adult outpatients who met the DSM-IV-TR criteria for OCD based on the structured clinical interview participated in the trial. In this double-blind and randomized trial, patients were randomly assigned to receive either capsule of the extract (765 mg/day) or placebo (30 mg/day) for 8 weeks. The results showed significant difference between the extract and placebo in the end of treatment (P=0.000). Somnolence was the only significant difference between the two groups in terms of observed side effects (P=0.02). The results suggest that Valeriana Officinalis L. has some antiobsessive and compulsive effects. However, further studies are needed to confirm these findings. Psychiatrists often find that many patients cannot tolerate the side effects of psychiatry medicine Valeriana Officinalis L. is a well-known medicinal plant with a long history of usage in world with effect on GABA.The results showed significant difference between the extract and placebo in the treatment of OCD. There was also no significant difference between the two groups in terms of observed side effects.
Color-Blindness Study: Color Discrimination on the TICCIT System.
ERIC Educational Resources Information Center
Asay, Calvin S.; Schneider, Edward W.
The question studied whether the specific seven TICCIT system colors used within color coding schemes can be a source of confusion, or not seen at all, by the color-blind segment of target populations. Subjects were 11 color-blind and three normally sighted students at Brigham Young University. After a preliminary training exercise to acquaint the…
Literature on the Deaf-Blind -- An Annotated Bibliography.
ERIC Educational Resources Information Center
Blea, William A., Comp.; Hobron, Robert, Comp.
The annotated bibliography of literature on the deaf-blind covers both a wide variety of sources and a lengthy period of time. Entries are listed by category: selected books; articles from American Annals of the Deaf, 1848-1970; articles from New Beacon, 1922-1970; articles from New Outlook for the Blind, 1907-1970; articles from Volta Review,…
Koster-Hale, Jorie; Bedny, Marina; Saxe, Rebecca
2014-01-01
Blind people's inferences about how other people see provide a window into fundamental questions about the human capacity to think about one another's thoughts. By working with blind individuals, we can ask both what kinds of representations people form about others’ minds, and how much these representations depend on the observer having had similar mental states themselves. Thinking about others’ mental states depends on a specific group of brain regions, including the right temporo-parietal junction (RTPJ). We investigated the representations of others’ mental states in these brain regions, using multivoxel pattern analyses (MVPA). We found that, first, in the RTPJ of sighted adults, the pattern of neural response distinguished the source of the mental state (did the protagonist see or hear something?) but not the valence (did the protagonist feel good or bad?). Second, these neural representations were preserved in congenitally blind adults. These results suggest that the temporo-parietal junction contains explicit, abstract representations of features of others’ mental states, including the perceptual source. The persistence of these representations in congenitally blind adults, who have no first-person experience with sight, provides evidence that these representations emerge even in the absence of first-person perceptual experiences. PMID:24960530
Koster-Hale, Jorie; Bedny, Marina; Saxe, Rebecca
2014-10-01
Blind people's inferences about how other people see provide a window into fundamental questions about the human capacity to think about one another's thoughts. By working with blind individuals, we can ask both what kinds of representations people form about others' minds, and how much these representations depend on the observer having had similar mental states themselves. Thinking about others' mental states depends on a specific group of brain regions, including the right temporo-parietal junction (RTPJ). We investigated the representations of others' mental states in these brain regions, using multivoxel pattern analyses (MVPA). We found that, first, in the RTPJ of sighted adults, the pattern of neural response distinguished the source of the mental state (did the protagonist see or hear something?) but not the valence (did the protagonist feel good or bad?). Second, these neural representations were preserved in congenitally blind adults. These results suggest that the temporo-parietal junction contains explicit, abstract representations of features of others' mental states, including the perceptual source. The persistence of these representations in congenitally blind adults, who have no first-person experience with sight, provides evidence that these representations emerge even in the absence of relevant first-person perceptual experiences. Copyright © 2014 Elsevier B.V. All rights reserved.
Abboud, Sami; Hanassy, Shlomi; Levy-Tzedek, Shelly; Maidenbaum, Shachar; Amedi, Amir
2014-01-01
Sensory-substitution devices (SSDs) provide auditory or tactile representations of visual information. These devices often generate unpleasant sensations and mostly lack color information. We present here a novel SSD aimed at addressing these issues. We developed the EyeMusic, a novel visual-to-auditory SSD for the blind, providing both shape and color information. Our design uses musical notes on a pentatonic scale generated by natural instruments to convey the visual information in a pleasant manner. A short behavioral protocol was utilized to train the blind to extract shape and color information, and test their acquired abilities. Finally, we conducted a survey and a comparison task to assess the pleasantness of the generated auditory stimuli. We show that basic shape and color information can be decoded from the generated auditory stimuli. High performance levels were achieved by all participants following as little as 2-3 hours of training. Furthermore, we show that users indeed found the stimuli pleasant and potentially tolerable for prolonged use. The novel EyeMusic algorithm provides an intuitive and relatively pleasant way for the blind to extract shape and color information. We suggest that this might help facilitating visual rehabilitation because of the added functionality and enhanced pleasantness.
Removal of EOG Artifacts from EEG Recordings Using Stationary Subspace Analysis
Zeng, Hong; Song, Aiguo
2014-01-01
An effective approach is proposed in this paper to remove ocular artifacts from the raw EEG recording. The proposed approach first conducts the blind source separation on the raw EEG recording by the stationary subspace analysis (SSA) algorithm. Unlike the classic blind source separation algorithms, SSA is explicitly tailored to the understanding of distribution changes, where both the mean and the covariance matrix are taken into account. In addition, neither independency nor uncorrelation is required among the sources by SSA. Thereby, it can concentrate artifacts in fewer components than the representative blind source separation methods. Next, the components that are determined to be related to the ocular artifacts are projected back to be subtracted from EEG signals, producing the clean EEG data eventually. The experimental results on both the artificially contaminated EEG data and real EEG data have demonstrated the effectiveness of the proposed method, in particular for the cases where limited number of electrodes are used for the recording, as well as when the artifact contaminated signal is highly nonstationary and the underlying sources cannot be assumed to be independent or uncorrelated. PMID:24550696
SCoT: a Python toolbox for EEG source connectivity.
Billinger, Martin; Brunner, Clemens; Müller-Putz, Gernot R
2014-01-01
Analysis of brain connectivity has become an important research tool in neuroscience. Connectivity can be estimated between cortical sources reconstructed from the electroencephalogram (EEG). Such analysis often relies on trial averaging to obtain reliable results. However, some applications such as brain-computer interfaces (BCIs) require single-trial estimation methods. In this paper, we present SCoT-a source connectivity toolbox for Python. This toolbox implements routines for blind source decomposition and connectivity estimation with the MVARICA approach. Additionally, a novel extension called CSPVARICA is available for labeled data. SCoT estimates connectivity from various spectral measures relying on vector autoregressive (VAR) models. Optionally, these VAR models can be regularized to facilitate ill posed applications such as single-trial fitting. We demonstrate basic usage of SCoT on motor imagery (MI) data. Furthermore, we show simulation results of utilizing SCoT for feature extraction in a BCI application. These results indicate that CSPVARICA and correct regularization can significantly improve MI classification. While SCoT was mainly designed for application in BCIs, it contains useful tools for other areas of neuroscience. SCoT is a software package that (1) brings combined source decomposition and connectivtiy estimation to the open Python platform, and (2) offers tools for single-trial connectivity estimation. The source code is released under the MIT license and is available online at github.com/SCoT-dev/SCoT.
SCoT: a Python toolbox for EEG source connectivity
Billinger, Martin; Brunner, Clemens; Müller-Putz, Gernot R.
2014-01-01
Analysis of brain connectivity has become an important research tool in neuroscience. Connectivity can be estimated between cortical sources reconstructed from the electroencephalogram (EEG). Such analysis often relies on trial averaging to obtain reliable results. However, some applications such as brain-computer interfaces (BCIs) require single-trial estimation methods. In this paper, we present SCoT—a source connectivity toolbox for Python. This toolbox implements routines for blind source decomposition and connectivity estimation with the MVARICA approach. Additionally, a novel extension called CSPVARICA is available for labeled data. SCoT estimates connectivity from various spectral measures relying on vector autoregressive (VAR) models. Optionally, these VAR models can be regularized to facilitate ill posed applications such as single-trial fitting. We demonstrate basic usage of SCoT on motor imagery (MI) data. Furthermore, we show simulation results of utilizing SCoT for feature extraction in a BCI application. These results indicate that CSPVARICA and correct regularization can significantly improve MI classification. While SCoT was mainly designed for application in BCIs, it contains useful tools for other areas of neuroscience. SCoT is a software package that (1) brings combined source decomposition and connectivtiy estimation to the open Python platform, and (2) offers tools for single-trial connectivity estimation. The source code is released under the MIT license and is available online at github.com/SCoT-dev/SCoT. PMID:24653694
Kolarik, Andrew J; Cirstea, Silvia; Pardhan, Shahina
2013-02-01
Totally blind listeners often demonstrate better than normal capabilities when performing spatial hearing tasks. Accurate representation of three-dimensional auditory space requires the processing of available distance information between the listener and the sound source; however, auditory distance cues vary greatly depending upon the acoustic properties of the environment, and it is not known which distance cues are important to totally blind listeners. Our data show that totally blind listeners display better performance compared to sighted age-matched controls for distance discrimination tasks in anechoic and reverberant virtual rooms simulated using a room-image procedure. Totally blind listeners use two major auditory distance cues to stationary sound sources, level and direct-to-reverberant ratio, more effectively than sighted controls for many of the virtual distances tested. These results show that significant compensation among totally blind listeners for virtual auditory spatial distance leads to benefits across a range of simulated acoustic environments. No significant differences in performance were observed between listeners with partial non-correctable visual losses and sighted controls, suggesting that sensory compensation for virtual distance does not occur for listeners with partial vision loss.
FISSA: A neuropil decontamination toolbox for calcium imaging signals.
Keemink, Sander W; Lowe, Scott C; Pakan, Janelle M P; Dylda, Evelyn; van Rossum, Mark C W; Rochefort, Nathalie L
2018-02-22
In vivo calcium imaging has become a method of choice to image neuronal population activity throughout the nervous system. These experiments generate large sequences of images. Their analysis is computationally intensive and typically involves motion correction, image segmentation into regions of interest (ROIs), and extraction of fluorescence traces from each ROI. Out of focus fluorescence from surrounding neuropil and other cells can strongly contaminate the signal assigned to a given ROI. In this study, we introduce the FISSA toolbox (Fast Image Signal Separation Analysis) for neuropil decontamination. Given pre-defined ROIs, the FISSA toolbox automatically extracts the surrounding local neuropil and performs blind-source separation with non-negative matrix factorization. Using both simulated and in vivo data, we show that this toolbox performs similarly or better than existing published methods. FISSA requires only little RAM, and allows for fast processing of large datasets even on a standard laptop. The FISSA toolbox is available in Python, with an option for MATLAB format outputs, and can easily be integrated into existing workflows. It is available from Github and the standard Python repositories.
The Comparison Between Nmf and Ica in Pigment Mixture Identification of Ancient Chinese Paintings
NASA Astrophysics Data System (ADS)
Liu, Y.; Lyu, S.; Hou, M.; Yin, Q.
2018-04-01
Since the colour in painting cultural relics observed by our naked eyes or hyperspectral cameras is usually a mixture of several kinds of pigments, the mixed pigments analysis will be an important subject in the field of ancient painting conservation and restoration. This paper aims to find a more effective method to confirm the types of every pure pigment from mixture on the surface of paintings. Firstly, we adopted two kinds of blind source separation algorithms, which are independent component analysis and non-negative matrix factorization, to extract the pure pigment component from mixed spectrum respectively. Moreover, we matched the separated pure spectrum with the pigments spectra library built by our team to determine the pigment type. Furthermore, three kinds of data including simulation data, mixed pigments spectral data measured in laboratory, and the spectral data of an ancient painting were chosen to evaluate the performance of the different algorithms. And the accuracy was compared between the two algorithms. Finally, the experimental results show that non-negative matrix factorization method is more suitable for endmember extraction in the field of ancient painting conservation and restoration.
Amsterdam, Jay D; Li, Yimei; Soeller, Irene; Rockwell, Kenneth; Mao, Jun James; Shults, Justine
2009-08-01
We conducted a randomized, double-blind, placebo-controlled efficacy and tolerability trial of Matricaria recutita (chamomile) extract therapy in patients with mild to moderate generalized anxiety disorder (GAD). We hypothesized that chamomile would be superior to placebo in reducing GAD symptoms with a comparable tolerability profile. Sixty-one outpatients with mild to moderate GAD were enrolled, and 57 were randomized to either double-blind chamomile extract (n = 28) or placebo therapy (n = 29) for 8 weeks. The study was powered to detect a statistically significant and clinically meaningful group difference in change over time in total Hamilton Anxiety Rating (HAM-A) scores. Secondary outcomes included change in the Beck Anxiety Inventory, Psychological Well Being, and Clinical Global Impression Severity scores and the proportion of patients with 50% reduction or more in baseline HAM-A score. We observed a significantly greater reduction in mean total HAM-A score during chamomile versus placebo therapy (P = 0.047). Although the study was not powered to identify small to moderate differences in secondary outcomes, we observed a positive change in all secondary outcomes in the same direction as the primary outcome measure. One patient in each treatment group discontinued therapy for adverse events. The proportion of patients experiencing 0, 1, 2, or 3 adverse events or more was not significantly different between groups (P = 0.417). This is the first controlled clinical trial of chamomile extract for GAD. The results suggest that chamomile may have modest anxiolytic activity in patients with mild to moderate GAD. Future studies are needed to replicate these observations.
Ramke, Jacqueline; Kuper, Hannah; Limburg, Hans; Kinloch, Jennifer; Zhu, Wenhui; Lansingh, Van C; Congdon, Nathan; Foster, Allen; Gilbert, Clare E
2018-02-01
Sources of avoidable waste in ophthalmic epidemiology include duplication of effort, and survey reports remaining unpublished, gaining publication after a long delay, or being incomplete or of poor quality. The aim of this review was to assess these sources of avoidable waste by examining blindness prevalence surveys undertaken in low and middle income countries (LMICs) between 2000 and 2014. On December 1, 2016 we searched MEDLINE, EMBASE and Web of Science databases for cross-sectional blindness prevalence surveys undertaken in LMICs between 2000 and 2014. All surveys listed on the Rapid Assessment of Avoidable Blindness (RAAB) Repository website ("the Repository") were also considered. For each survey we assessed (1) availability of scientific publication, survey report, summary results tables and/or datasets; (2) time to publication from year of survey completion and journal attributes; (3) extent of blindness information reported; and (4) rigour when information was available from two sources (i.e. whether it matched). Of the 279 included surveys (from 68 countries) 186 (67%) used RAAB methodology; 146 (52%) were published in a scientific journal, 57 (20%) were published in a journal and on the Repository, and 76 (27%) were on the Repository only (8% had tables; 19% had no information available beyond registration). Datasets were available for 50 RAABs (18% of included surveys). Time to publication ranged from <1 to 11 years (mean, standard deviation 2.8 ± 1.8 years). The extent of blindness information reported within studies varied (e.g. presenting and best-corrected, unilateral and bilateral); those with both a published report and Repository tables were most complete. For surveys published and with RAAB tables available, discrepancies were found in reporting of participant numbers (14% of studies) and blindness prevalence (15%). Strategies are needed to improve the availability, consistency, and quality of information reported from blindness prevalence surveys, and hence reduce avoidable waste.
Velliquette, Rodney A; Grann, Kerry; Missler, Stephen R; Patterson, Jennifer; Hu, Chun; Gellenbeck, Kevin W; Scholten, Jeffrey D; Randolph, R Keith
2015-01-01
Diacylglyceride acyltransferase 1 (DGAT1) is the enzyme that adds the final fatty acid on to a diacylglyceride during triglyceride (TG) synthesis. DGAT1 plays a key role in the repackaging of dietary TG into circulating TG rich chylomicrons. A growing amount of research has indicated that an exaggerated postprandial circulating TG level is a risk indicator for cardiovascular and metabolic disorders. The aim of this research was to identify a botanical extract that inhibits intestinal DGAT1 activity and attenuates postprandial hypertriglyceridemia in overweight and obese humans. Twenty individual phytochemicals and an internal proprietary botanical extract library were screened with a primary cell-free DGAT1 enzyme assay that contained dioleoyl glycerol and palmitoleoyl Coenzyme A as substrates plus human intestinal microsomes as the DGAT1 enzyme source. Botanical extracts with IC50 values < 100 μg/mL were evaluated in a cellular DGAT1 assay. The cellular DGAT1 assay comprised the analysis of (14)C labeled TG synthesis in cells incubated with (14)C-glycerol and 0.3 mM oleic acid. Lead botanical extracts were then evaluated in a parallel, double-blind, placebo-controlled clinical trial. Ninety healthy, overweight and obese participants were randomized to receive 2 g daily of placebo or individual botanical extracts (the investigational product) for seven days. Serum TG levels were measured before and after consuming a high fat meal (HFM) challenge (0.354 L drink/shake; 77 g fat, 25 g carbohydrate and 9 g protein) as a marker of intestinal DGAT1 enzyme activity. Phenolic acids (i.e., gallic acid) and polyphenols (i.e., cyanidin) abundantly found in nature appeared to inhibit DGAT1 enzyme activity in vitro. Four polyphenolic rich botanical extracts were identified from in vitro evaluation in both cell-free and cellular model systems: apple peel extract (APE), grape extract (GE), red raspberry leaf extract (RLE) and apricot/nectarine extract (ANE) (IC50 = 1.4, 5.6, and 10.4 and 3.4 μg/mL, respectively). In the seven day clinical trial, compared to placebo, only GE significantly reduced the baseline subtracted change in serum TG AUC following consumption of the HFM (AUC = 281 ± 37 vs. 181 ± 30 mg/dL*h, respectively; P = 0.021). Chromatographic characterization of the GE revealed a large number of closely eluting components containing proanthocyanidins, catechins, anthocyanins and their secondary metabolites that corresponded with the observed DGAT1 enzyme inhibition in the cell-free model. These data suggest that a dietary GE has the potential to attenuate postprandial hypertriglyceridemia in part by the inhibition of intestinal DGAT1 enzyme activity without intolerable side effects. This trial was registered with ClinicalTrials.gov NCT02333461.
Voss, Patrice; Gougoux, Frederic; Zatorre, Robert J; Lassonde, Maryse; Lepore, Franco
2008-04-01
Blind individuals do not necessarily receive more auditory stimulation than sighted individuals. However, to interact effectively with their environment, they have to rely on non-visual cues (in particular auditory) to a greater extent. Often benefiting from cerebral reorganization, they not only learn to rely more on such cues but also may process them better and, as a result, demonstrate exceptional abilities in auditory spatial tasks. Here we examine the effects of blindness on brain activity, using positron emission tomography (PET), during a sound-source discrimination task (SSDT) in both early- and late-onset blind individuals. This should not only provide an answer to the question of whether the blind manifest changes in brain activity but also allow a direct comparison of the two subgroups performing an auditory spatial task. The task was presented under two listening conditions: one binaural and one monaural. The binaural task did not show any significant behavioural differences between groups, but it demonstrated striate and extrastriate activation in the early-blind groups. A subgroup of early-blind individuals, on the other hand, performed significantly better than all the other groups during the monaural task, and these enhanced skills were correlated with elevated activity within the left dorsal extrastriate cortex. Surprisingly, activation of the right ventral visual pathway, which was significantly activated in the late-blind individuals during the monaural task, was negatively correlated with performance. This suggests the possibility that not all cross-modal plasticity is beneficial. Overall, our results not only support previous findings showing that occipital cortex of early-blind individuals is functionally engaged in spatial auditory processing but also shed light on the impact the age of onset of blindness can have on the ensuing cross-modal plasticity.
NASA Astrophysics Data System (ADS)
Jany, B. R.; Janas, A.; Krok, F.
2017-11-01
The quantitative composition of metal alloy nanowires on InSb(001) semiconductor surface and gold nanostructures on germanium surface is determined by blind source separation (BSS) machine learning (ML) method using non negative matrix factorization (NMF) from energy dispersive X-ray spectroscopy (EDX) spectrum image maps measured in a scanning electron microscope (SEM). The BSS method blindly decomposes the collected EDX spectrum image into three source components, which correspond directly to the X-ray signals coming from the supported metal nanostructures, bulk semiconductor signal and carbon background. The recovered quantitative composition is validated by detailed Monte Carlo simulations and is confirmed by separate cross-sectional TEM EDX measurements of the nanostructures. This shows that SEM EDX measurements together with machine learning blind source separation processing could be successfully used for the nanostructures quantitative chemical composition determination.
Classical-processing and quantum-processing signal separation methods for qubit uncoupling
NASA Astrophysics Data System (ADS)
Deville, Yannick; Deville, Alain
2012-12-01
The Blind Source Separation problem consists in estimating a set of unknown source signals from their measured combinations. It was only investigated in a non-quantum framework up to now. We propose its first quantum extensions. We thus introduce the Quantum Source Separation field, investigating both its blind and non-blind configurations. More precisely, we show how to retrieve individual quantum bits (qubits) only from the global state resulting from their undesired coupling. We consider cylindrical-symmetry Heisenberg coupling, which e.g. occurs when two electron spins interact through exchange. We first propose several qubit uncoupling methods which typically measure repeatedly the coupled quantum states resulting from individual qubits preparations, and which then statistically process the classical data provided by these measurements. Numerical tests prove the effectiveness of these methods. We then derive a combination of quantum gates for performing qubit uncoupling, thus avoiding repeated qubit preparations and irreversible measurements.
Morris, J; Burke, V; Mori, T A; Vandongen, R; Beilin, L J
1995-01-01
1. Studies of the effects of garlic on platelet aggregation have produced inconsistent results possibly related to variations in study design and in the garlic preparations used. 2. The present study examined the effects on platelet aggregation and serum thromboxane and lyso-platelet activating factor, of feeding garlic extract to healthy men using a placebo-controlled, double-blind design. The effects of the same garlic preparation on platelet aggregation in vitro were also investigated. 3. There were no significant differences in platelet aggregation with adenosine diphosphate, platelet activating factor (PAF) or collagen according to treatment group. Serum thromboxane and lysoPAF also showed no change related to garlic supplements. 4. In vitro aggregation with collagen decreased linearly with increasing amounts of garlic extract, but concentrations were higher than those attainable in vivo. Gastrointestinal side effects prevented the use of higher doses of garlic which must be considered to be pharmacological as they exceed changes achievable by dietary modification.
Selective Listening Point Audio Based on Blind Signal Separation and Stereophonic Technology
NASA Astrophysics Data System (ADS)
Niwa, Kenta; Nishino, Takanori; Takeda, Kazuya
A sound field reproduction method is proposed that uses blind source separation and a head-related transfer function. In the proposed system, multichannel acoustic signals captured at distant microphones are decomposed to a set of location/signal pairs of virtual sound sources based on frequency-domain independent component analysis. After estimating the locations and the signals of the virtual sources by convolving the controlled acoustic transfer functions with each signal, the spatial sound is constructed at the selected point. In experiments, a sound field made by six sound sources is captured using 48 distant microphones and decomposed into sets of virtual sound sources. Since subjective evaluation shows no significant difference between natural and reconstructed sound when six virtual sources and are used, the effectiveness of the decomposing algorithm as well as the virtual source representation are confirmed.
Siepmann, Martin; Kirch, Wilhelm; Krause, Stephanie; Joraschky, Peter; Mueck-Weymann, Michael
2004-02-01
St. John's wort extract is widely used and advertised as a "natural antidepressant" lacking autonomic side effects. This randomized, double-blind, placebo-controlled study compared the effects of St. John's wort extract on autonomic responses of blood vessels and sweat glands with those of amitriptyline and placebo. A randomized, double-blind, crossover study was performed in healthy male volunteers aged 22 to 31 years (25 +/- 3 years; mean +/- SD) years. Subjects orally received capsules with 255 to 285 mg St. John's wort extract (900 microg hypericin content), 25 mg amitriptyline, and placebo 3 times daily for periods of 14 days each with at least 14 days between. Vasoconstrictory response of cutaneous blood flow (VR) and skin conductance response (SR) following a single deep inspiration were employed as parameters of autonomic function. St. John's wort extract had no effect on VR and SR. In contrast, SR was diminished and the dilation phase of VR was prolonged following multiple dosing with amitriptyline (P < 0.05). Decreased electrodermal reactivity observed with amitriptyline reflects inhibition of acetylcholine at peripheral m3-cholinoreceptors, whereas prolongation of VR induced by the tricyclic drug may be due to sustained activation of central and/or peripheral sympathetic neurons.
Werner, Natalie S; Duschek, Stefan; Schandry, Rainer
2009-12-01
The present study investigated whether the D-camphor-crataegus berry extract combination Korodin elevates blood pressure and enhances cognitive performance in the elderly population. Eighty women aged between 50 and 80 years were examined based on a randomized, placebo controlled double blind design. Blood pressure was measured sphygmomanometrically and through continuous noninvasive recording. Cognitive performance was assessed by means of two tests measuring general information processing capacity and visuomotor speed. The administration of the drug led to a short term increase in blood pressure as well as in cognitive performance as compared to placebo. Potential physiological mechanisms of action mediating this effect, including hemodynamic alterations, sympathetic stimulation as well as improvement of cerebral metabolism are discussed.
Lifetime risk of blindness in open-angle glaucoma.
Peters, Dorothea; Bengtsson, Boel; Heijl, Anders
2013-10-01
To determine the lifetime risk and duration of blindness in patients with manifest open-angle glaucoma (OAG). Retrospective chart review. We studied glaucoma patients who died between January 2006 and June 2010. Most glaucoma patients living in the catchment area (city of Malmö; n = 305 000) are managed at the Department of Ophthalmology at Skåne University Hospital in Malmö. From the patient records we extracted visual field status, visual acuity, and low vision or blindness as defined by the World Health Organization (WHO) criteria and caused by glaucoma at the time of diagnosis and during follow-up. We also noted age at diagnosis and death and when low vision or blindness occurred. Five hundred and ninety-two patients were included. At the time of the last visit 250 patients (42.2%) had at least 1 blind eye because of glaucoma, while 97 patients (16.4%) were bilaterally blind, and 12 patients (0.5%) had low vision. Median time with a glaucoma diagnosis was 12 years (<1-29), median age when developing bilateral blindness was 86 years, and median duration of bilateral blindness was 2 years (<1-13). The cumulative incidences of blindness in at least 1 eye and bilateral blindness from glaucoma were 26.5% and 5.5%, respectively, after 10 years, and 38.1% and 13.5% at 20 years. Approximately 1 out of 6 glaucoma patients was bilaterally blind from glaucoma at the last visit. Median duration of bilateral blindness was 2 years. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Cho-Ngwa, Fidelis; Monya, Elvis; Azantsa, Boris K; Manfo, Faustin Pascal T; Babiaka, Smith B; Mbah, James A; Samje, Moses
2016-08-30
Onchocerciasis is the world's second leading infectious cause of blindness. Its control is currently hampered by the lack of a macrofilaricidal drug and by severe adverse events observed when the lone recommended microfilaricide, ivermectin is administered to individuals co-infected with Loa loa. Therefore, there is the need for a safe and effective macrofilaricidal drug that will be able to cure the infection and break transmission cycles, or at least, an alternative microfilaricide that does not kill L. loa microfilariae (mf). Fourteen extracts from two medicinal plants, Tragia benthami and Piper umbellatum were screened in vitro against Onchocerca ochengi parasite and L. loa mf. Activities of extracts on male worms and microfilariae were assessed by motility reduction, while MTT/Formazan assay was used to assess biochemically the death of female worms. Cytotoxicity and acute toxicity of active extracts were tested on monkey kidney cells and Balb/c mice, respectively. At 500 μg/mL, all extracts showed 100 % activity on Onchocerca ochengi males and microfilariae, while 9 showed 100 % activity on female worms. The methylene chloride extract of Piper umbellatum leaves was the most active on adult male and female worms (IC50s: 16.63 μg/mL and 35.65 μg/mL, respectively). The three most active extracts on Onchocerca ochengi females were also highly active on Loa loa microfilariae, with IC50s of 35.12 - 13.9 μg/mL. Active extracts were generally more toxic to the worms than to cells and showed no acute toxicity to Balb/c mice. Phytochemical screening revealed the presence of saponins, steroids, tannins and flavanoids in the promising extracts. These results unfold potential sources of novel anti-Onchocerca lead compounds and validate the traditional use of the plants in onchocerciasis treatment.
A review of multivariate methods in brain imaging data fusion
NASA Astrophysics Data System (ADS)
Sui, Jing; Adali, Tülay; Li, Yi-Ou; Yang, Honghui; Calhoun, Vince D.
2010-03-01
On joint analysis of multi-task brain imaging data sets, a variety of multivariate methods have shown their strengths and been applied to achieve different purposes based on their respective assumptions. In this paper, we provide a comprehensive review on optimization assumptions of six data fusion models, including 1) four blind methods: joint independent component analysis (jICA), multimodal canonical correlation analysis (mCCA), CCA on blind source separation (sCCA) and partial least squares (PLS); 2) two semi-blind methods: parallel ICA and coefficient-constrained ICA (CC-ICA). We also propose a novel model for joint blind source separation (BSS) of two datasets using a combination of sCCA and jICA, i.e., 'CCA+ICA', which, compared with other joint BSS methods, can achieve higher decomposition accuracy as well as the correct automatic source link. Applications of the proposed model to real multitask fMRI data are compared to joint ICA and mCCA; CCA+ICA further shows its advantages in capturing both shared and distinct information, differentiating groups, and interpreting duration of illness in schizophrenia patients, hence promising applicability to a wide variety of medical imaging problems.
NASA Astrophysics Data System (ADS)
Capuano, P.; De Lauro, E.; De Martino, S.; Falanga, M.
2016-04-01
This work is devoted to the analysis of seismic signals continuously recorded at Campi Flegrei Caldera (Italy) during the entire year 2006. The radiation pattern associated with the Long-Period energy release is investigated. We adopt an innovative Independent Component Analysis algorithm for convolutive seismic series adapted and improved to give automatic procedures for detecting seismic events often buried in the high-level ambient noise. The extracted waveforms characterized by an improved signal-to-noise ratio allows the recognition of Long-Period precursors, evidencing that the seismic activity accompanying the mini-uplift crisis (in 2006), which climaxed in the three days from 26-28 October, had already started at the beginning of the month of October and lasted until mid of November. Hence, a more complete seismic catalog is then provided which can be used to properly quantify the seismic energy release. To better ground our results, we first check the robustness of the method by comparing it with other blind source separation methods based on higher order statistics; secondly, we reconstruct the radiation patterns of the extracted Long-Period events in order to link the individuated signals directly to the sources. We take advantage from Convolutive Independent Component Analysis that provides basic signals along the three directions of motion so that a direct polarization analysis can be performed with no other filtering procedures. We show that the extracted signals are mainly composed of P waves with radial polarization pointing to the seismic source of the main LP swarm, i.e. a small area in the Solfatara, also in the case of the small-events, that both precede and follow the main activity. From a dynamical point of view, they can be described by two degrees of freedom, indicating a low-level of complexity associated with the vibrations from a superficial hydrothermal system. Our results allow us to move towards a full description of the complexity of the source, which can be used, by means of the small-intensity precursors, for hazard-model development and forecast-model testing, showing an illustrative example of the applicability of the CICA method to regions with low seismicity in high ambient noise.
Code of Federal Regulations, 2011 CFR
2011-10-01
... REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition From Nonprofit Agencies Employing People Who Are... designated to represent people who are blind; or NISH, which has been designated to represent AbilityOne participating nonprofit agencies serving people with severe disabilities other than blindness. Committee, means...
Rao, Amanda; Steels, Elizabeth; Inder, Warrick J; Abraham, Suzanne; Vitetta, Luis
2016-06-01
This study examined the effect of Testofen, a specialised Trigonella foenum-graecum seed extract on the symptoms of possible androgen deficiency, sexual function and serum androgen concentrations in healthy aging males. This was a double-blind, randomised, placebo-controlled trial involving 120 healthy men aged between 43 and 70 years of age. The active treatment was standardised Trigonella foenum-graecum seed extract at a dose of 600 mg/day for 12 weeks. The primary outcome measure was the change in the Aging Male Symptom questionnaire (AMS), a measure of possible androgen deficiency symptoms; secondary outcome measures were sexual function and serum testosterone. There was a significant decrease in AMS score over time and between the active and placebo groups. Sexual function improved, including number of morning erections and frequency of sexual activity. Both total serum testosterone and free testosterone increased compared to placebo after 12 weeks of active treatment. Trigonella foenum-graecum seed extract is a safe and effective treatment for reducing symptoms of possible androgen deficiency, improves sexual function and increases serum testosterone in healthy middle-aged and older men.
Independent component analysis algorithm FPGA design to perform real-time blind source separation
NASA Astrophysics Data System (ADS)
Meyer-Baese, Uwe; Odom, Crispin; Botella, Guillermo; Meyer-Baese, Anke
2015-05-01
The conditions that arise in the Cocktail Party Problem prevail across many fields creating a need for of Blind Source Separation. The need for BSS has become prevalent in several fields of work. These fields include array processing, communications, medical signal processing, and speech processing, wireless communication, audio, acoustics and biomedical engineering. The concept of the cocktail party problem and BSS led to the development of Independent Component Analysis (ICA) algorithms. ICA proves useful for applications needing real time signal processing. The goal of this research was to perform an extensive study on ability and efficiency of Independent Component Analysis algorithms to perform blind source separation on mixed signals in software and implementation in hardware with a Field Programmable Gate Array (FPGA). The Algebraic ICA (A-ICA), Fast ICA, and Equivariant Adaptive Separation via Independence (EASI) ICA were examined and compared. The best algorithm required the least complexity and fewest resources while effectively separating mixed sources. The best algorithm was the EASI algorithm. The EASI ICA was implemented on hardware with Field Programmable Gate Arrays (FPGA) to perform and analyze its performance in real time.
Amsterdam, Jay D.; Li, Yimei; Soeller, Irene; Rockwell, Kenneth; Mao, Jun James; Shults, Justine
2013-01-01
Objective We conducted a randomized, double-blind, placebo-controlled efficacy and tolerability trial of Matricaria recutita (chamomile) extract therapy in patients with mild to moderate Generalized Anxiety Disorder (GAD). We hypothesized that chamomile would be superior to placebo in reducing GAD symptoms with a comparable tolerability profile. Materials & Methods 61 outpatients with mild to moderate GAD were enrolled and 57 were randomized to either double blind chamomile extract (n=28) or placebo (n=29) therapy for 8 weeks. The study was powered to detect a statistically significant and clinically meaningful group difference in change over time in total Hamilton Anxiety Rating (HAM-A) scores. Secondary outcomes included change in the Beck Anxiety Inventory score, Psychological Well Being score, Clinical Global Impression Severity score, and the proportion of patients with ≥50% reduction in baseline HAM-A score. Results We observed a significantly greater reduction in mean total HAM-A score during chamomile versus placebo therapy (p=0.047). Although the study was not powered to identify small to moderate differences in secondary outcomes, we observed a positive change in all secondary outcomes in the same direction as the primary outcome measure. One patient in each treatment group discontinued therapy for adverse events. The proportion of patients experiencing 0, 1, 2, or ≥3 adverse events was not significantly different between groups (p=0.417). Conclusion This is the first, controlled clinical trial of chamomile extract for GAD. The results suggest that chamomile may have modest anxiolytic activity in patients with mild to moderate GAD. Future studies are needed to replicate these observations. PMID:19593179
Reading Machines for Blind People.
ERIC Educational Resources Information Center
Fender, Derek H.
1983-01-01
Ten stages of developing reading machines for blind people are analyzed: handling of text material; optics; electro-optics; pattern recognition; character recognition; storage; speech synthesizers; browsing and place finding; computer indexing; and other sources of input. Cost considerations of the final product are emphasized. (CL)
Santaguida, Pasqualina; Oremus, Mark; Walker, Kathryn; Wishart, Laurie R; Siegel, Karen Lohmann; Raina, Parminder
2012-04-01
A "review of reviews" was undertaken to assess methodological issues in studies evaluating nondrug rehabilitation interventions in stroke patients. MEDLINE, CINAHL, PsycINFO, and the Cochrane Database of Systematic Reviews were searched from January 2000 to January 2008 within the stroke rehabilitation setting. Electronic searches were supplemented by reviews of reference lists and citations identified by experts. Eligible studies were systematic reviews; excluded citations were narrative reviews or reviews of reviews. Review characteristics and criteria for assessing methodological quality of primary studies within them were extracted. The search yielded 949 English-language citations. We included a final set of 38 systematic reviews. Cochrane reviews, which have a standardized methodology, were generally of higher methodological quality than non-Cochrane reviews. Most systematic reviews used standardized quality assessment criteria for primary studies, but not all were comprehensive. Reviews showed that primary studies had problems with randomization, allocation concealment, and blinding. Baseline comparability, adverse events, and co-intervention or contamination were not consistently assessed. Blinding of patients and providers was often not feasible and was not evaluated as a source of bias. The eligible systematic reviews identified important methodological flaws in the evaluated primary studies, suggesting the need for improvement of research methods and reporting. Copyright © 2012 Elsevier Inc. All rights reserved.
Elayavilli, Ravikumar Komandur; Liu, Hongfang
2016-01-01
Computational modeling of biological cascades is of great interest to quantitative biologists. Biomedical text has been a rich source for quantitative information. Gathering quantitative parameters and values from biomedical text is one significant challenge in the early steps of computational modeling as it involves huge manual effort. While automatically extracting such quantitative information from bio-medical text may offer some relief, lack of ontological representation for a subdomain serves as impedance in normalizing textual extractions to a standard representation. This may render textual extractions less meaningful to the domain experts. In this work, we propose a rule-based approach to automatically extract relations involving quantitative data from biomedical text describing ion channel electrophysiology. We further translated the quantitative assertions extracted through text mining to a formal representation that may help in constructing ontology for ion channel events using a rule based approach. We have developed Ion Channel ElectroPhysiology Ontology (ICEPO) by integrating the information represented in closely related ontologies such as, Cell Physiology Ontology (CPO), and Cardiac Electro Physiology Ontology (CPEO) and the knowledge provided by domain experts. The rule-based system achieved an overall F-measure of 68.93% in extracting the quantitative data assertions system on an independently annotated blind data set. We further made an initial attempt in formalizing the quantitative data assertions extracted from the biomedical text into a formal representation that offers potential to facilitate the integration of text mining into ontological workflow, a novel aspect of this study. This work is a case study where we created a platform that provides formal interaction between ontology development and text mining. We have achieved partial success in extracting quantitative assertions from the biomedical text and formalizing them in ontological framework. The ICEPO ontology is available for download at http://openbionlp.org/mutd/supplementarydata/ICEPO/ICEPO.owl.
The Arecibo Galaxy Environment Survey - VII. A dense filament with extremely long H I streams
NASA Astrophysics Data System (ADS)
Taylor, R.; Minchin, R. F.; Herbst, H.; Davies, J. I.; Rodriguez, R.; Vazquez, C.
2014-09-01
We present completed observations of the NGC 7448 galaxy group and background volume as part of the blind neutral hydrogen Arecibo Galaxy Environment Survey. Our observations cover a region spanning 5°× 4°, over a redshift range of approximately -2000
Independent component analysis applied to long bunch beams in the Los Alamos Proton Storage Ring
NASA Astrophysics Data System (ADS)
Kolski, Jeffrey S.; Macek, Robert J.; McCrady, Rodney C.; Pang, Xiaoying
2012-11-01
Independent component analysis (ICA) is a powerful blind source separation (BSS) method. Compared to the typical BSS method, principal component analysis, ICA is more robust to noise, coupling, and nonlinearity. The conventional ICA application to turn-by-turn position data from multiple beam position monitors (BPMs) yields information about cross-BPM correlations. With this scheme, multi-BPM ICA has been used to measure the transverse betatron phase and amplitude functions, dispersion function, linear coupling, sextupole strength, and nonlinear beam dynamics. We apply ICA in a new way to slices along the bunch revealing correlations of particle motion within the beam bunch. We digitize beam signals of the long bunch at the Los Alamos Proton Storage Ring with a single device (BPM or fast current monitor) for an entire injection-extraction cycle. ICA of the digitized beam signals results in source signals, which we identify to describe varying betatron motion along the bunch, locations of transverse resonances along the bunch, measurement noise, characteristic frequencies of the digitizing oscilloscopes, and longitudinal beam structure.
Artificial retina model for the retinally blind based on wavelet transform
NASA Astrophysics Data System (ADS)
Zeng, Yan-an; Song, Xin-qiang; Jiang, Fa-gang; Chang, Da-ding
2007-01-01
Artificial retina is aimed for the stimulation of remained retinal neurons in the patients with degenerated photoreceptors. Microelectrode arrays have been developed for this as a part of stimulator. Design such microelectrode arrays first requires a suitable mathematical method for human retinal information processing. In this paper, a flexible and adjustable human visual information extracting model is presented, which is based on the wavelet transform. With the flexible of wavelet transform to image information processing and the consistent to human visual information extracting, wavelet transform theory is applied to the artificial retina model for the retinally blind. The response of the model to synthetic image is shown. The simulated experiment demonstrates that the model behaves in a manner qualitatively similar to biological retinas and thus may serve as a basis for the development of an artificial retina.
Halaska, M; Raus, K; Bĕles, P; Martan, A; Paithner, K G
1998-10-01
The aim of study presented here was to gather the data about the tolerability and efficacy of Vitex agnus castus (VACS) extract. The study was designed as double-blind, placebo controlled in two parallel groups (each 50 patients). Treatment phase lasted 3 consequent menstrual cycles (2 x 30 drops/day = 1.8 ml of VASC) or placebo. Mastalgia during at least 5 days of the cycle before the treatment was the strict inclusion condition. For assessment of the efficacy visual analogue scale was used. Altogether 97 patients were included into the statistical analysis (VACS: n = 48, placebo: n = 49). Intensity of breast pain diminished quicker with VACS group. The tolerability was satisfactory. We found VACS to be useful in the treatment of cyclical breast pain in women.
Soy germ extract alleviates menopausal hot flushes: placebo-controlled double-blind trial.
Imhof, Martin; Gocan, Anca; Imhof, Marianne; Schmidt, Mathias
2018-05-30
A double-blind, placebo-controlled study was performed to assess the potency of a soy germ preparation for the alleviation of menopausal hot flushes. Caucasian women with at least seven hot flushes daily were treated with soy germ extract (100 mg isoflavone glycosides) daily or with placebo for 12 weeks, followed by 12 weeks of open treatment with soy. Outcome parameters were the number of hot flushes and the evaluation of the Greene Climacteric Scale. A total of 192 women were included. As the hot flush diaries from one study centre were lost, the assessment of hot flushes was based on 136 participants (soy: 54 women; placebo: 82 women). After 12 weeks, 180 women were available for the analysis of Greene Scale and safety (soy and placebo: each 90 women). Hot flushes were reduced by 43.3% (-3.5 hot flushes) with soy and by 30.8% with placebo (-2.6; p < 0.001). After the open treatment phase with soy, both original groups showed a reduction of 68% of hot flushes. A subgroup analysis showed better effects for soy when symptoms were classified as "severe" at baseline. After 12 weeks of double-blind treatment, there was an improvement from baseline values of 71 and 78% with soy with the items "hot flushes" and "sweating", compared with 24% for both items with placebo. Hormonal safety parameters remained uninfluenced. Soy germ extract with 100 mg of isoflavone glycosides was shown to modestly, but significantly reduce menopausal hot flushes.
Quality Scalability Aware Watermarking for Visual Content.
Bhowmik, Deepayan; Abhayaratne, Charith
2016-11-01
Scalable coding-based content adaptation poses serious challenges to traditional watermarking algorithms, which do not consider the scalable coding structure and hence cannot guarantee correct watermark extraction in media consumption chain. In this paper, we propose a novel concept of scalable blind watermarking that ensures more robust watermark extraction at various compression ratios while not effecting the visual quality of host media. The proposed algorithm generates scalable and robust watermarked image code-stream that allows the user to constrain embedding distortion for target content adaptations. The watermarked image code-stream consists of hierarchically nested joint distortion-robustness coding atoms. The code-stream is generated by proposing a new wavelet domain blind watermarking algorithm guided by a quantization based binary tree. The code-stream can be truncated at any distortion-robustness atom to generate the watermarked image with the desired distortion-robustness requirements. A blind extractor is capable of extracting watermark data from the watermarked images. The algorithm is further extended to incorporate a bit-plane discarding-based quantization model used in scalable coding-based content adaptation, e.g., JPEG2000. This improves the robustness against quality scalability of JPEG2000 compression. The simulation results verify the feasibility of the proposed concept, its applications, and its improved robustness against quality scalable content adaptation. Our proposed algorithm also outperforms existing methods showing 35% improvement. In terms of robustness to quality scalable video content adaptation using Motion JPEG2000 and wavelet-based scalable video coding, the proposed method shows major improvement for video watermarking.
Weir, Iona; Shu, Quan; Wei, Nengding; Wei, Chengkai; Zhu, Yi
2018-01-01
Zyactinase® is an extract of green kiwifruit, formulated into the consumer healthcare products marketed as Phloe® and Kivia, used to assist in the relief of the symptoms associated with a range of digestive system dysfunction, including constipation and Irritable Bowel Syndrome (IBS). A randomised, double-blind, placebo-controlled clinical trial was undertaken to determine the ef-fects of the kiwifruit extract on bowel movement, stool formation and IBS associated symptoms amongst a sub-ject group of generally healthy individuals experiencing a period of moderate constipation. Fifty-eight partici-pants were randomized to the kiwifruit extract (28) or placebo (30). Selection criterion was decreased number of bowel movements (<3/week), with increased faecal hardness and IBS associated symptoms. The study ran for three weeks, with participants first undergoing a seven-day wash out period, followed by a seven-day dosing pe-riod, and then a seven-day follow up period. There was a significant increase in the defecation frequency (p<0.001), with a significant improvement in faecal score (p<0.01). There was a significant difference in pain-ful defecation and abdominal pain between the two groups (p<0.01). No side effects, including diarrhoea, urgen-cy or abdominal pain, were observed during the trial. The green kiwifruit extract significantly in-duced normal bowel movements with no adverse effects. The kiwifruit extract relieved constipation and the symptoms of IBS such as bloating, flatulence and abdominal pain.
Maruki-Uchida, Hiroko; Morita, Minoru; Yonei, Yoshikazu; Sai, Masahiko
2018-01-01
Piceatannol has been reported to have a wide variety of effects on the skin, including promoting collagen production, inhibiting melanin synthesis, inducing the antioxidant glutathione, and eliminating reactive oxygen species. In this study, a randomized, placebo-controlled, double-blind trial was conducted to clinically evaluate the effects of piceatannol-rich passion fruit seed extract on the skin of healthy Japanese women (age, 35-54 y). Thirty-two women with dry skin received either passion fruit seed extract (5 mg piceatannol) or a placebo (dextrin) for 8 wk. Skin hydration and other parameters on the face were assessed at 0, 4, and 8 wk by using specialized equipment. Furthermore, questionnaire interviews were conducted regarding the physical condition of subjects at 0, 4, and 8 wk. The results showed that consumption of passion fruit seed extract led to significant increases in the moisture content of human skin after 4 and 8 wk compared with that before the trial. The amount of transepidermal water loss decreased over time, although the differences were not significant. Moreover, a stratified analysis of subjects with moisture values of ≤200 μS revealed increased moisture content in the passion fruit seed extract group as compared with the placebo group. Furthermore, the results of questionnaires showed significant reductions in "perspiration" and "fatigue" in the passion fruit seed extract group as compared with the placebo group. These results indicate that oral intake of passion fruit seed extract that is rich in piceatannol could improve the moisture of dry skin and reduce fatigue.
Sugihara, Yoshihiko; Ikushima, Shigehito; Miyake, Mika; Kirisako, Takayoshi; Yada, Yukihiro; Fujiwara, Daisuke
2018-01-01
The present study examined the effect of ingestion of Koji extract containing 14-dehydroergosterol (14-DHE), prepared from Aspergillus kawachii NBRC4308, on improvement of skin conditions among healthy volunteers. In a randomized, double-blind, placebo-controlled, parallel-group study, 70 healthy adult women who felt that their skin was dry ingested either a placebo dietary supplement or Koji extract (200 mg/day) supplement containing 0.1% 14-DHE for 12 weeks. Throughout the treatment period and for 4 weeks afterward, objective indicators - including moisture content of the stratum corneum, trans-epidermal water loss (TEWL), and skin wrinkles - were evaluated; in addition, the subjects answered a questionnaire on their skin conditions with ratings on a visual analog scale. Statistical analysis was conducted on the basis of differences from baseline scores. Compared with the placebo group, the Koji extract group showed significantly increased forearm moisture at 4, 8, and 16 weeks ( p < 0.05 on unpaired t -test). The questionnaire survey showed a marked improvement in skin conditions, particularly crow's feet, in the Koji extract group versus the placebo group at 8 weeks ( p < 0.05 by unpaired t -test). Furthermore, the Koji extract group showed a trend ( p < 0.10) toward improvement in skin moisture (at 4 weeks), dryness around the eyes/mouth (at 4 weeks), and overall skin condition (at 8 weeks) versus the placebo group. Ingestion of Koji extract containing 14-DHE was demonstrated to have positive effects toward improving skin conditions - in particular, on increasing skin moisture in the stratum corneum.
Blind Channel Equalization with Colored Source Based on Constrained Optimization Methods
NASA Astrophysics Data System (ADS)
Wang, Yunhua; DeBrunner, Linda; DeBrunner, Victor; Zhou, Dayong
2008-12-01
Tsatsanis and Xu have applied the constrained minimum output variance (CMOV) principle to directly blind equalize a linear channel—a technique that has proven effective with white inputs. It is generally assumed in the literature that their CMOV method can also effectively equalize a linear channel with a colored source. In this paper, we prove that colored inputs will cause the equalizer to incorrectly converge due to inadequate constraints. We also introduce a new blind channel equalizer algorithm that is based on the CMOV principle, but with a different constraint that will correctly handle colored sources. Our proposed algorithm works for channels with either white or colored inputs and performs equivalently to the trained minimum mean-square error (MMSE) equalizer under high SNR. Thus, our proposed algorithm may be regarded as an extension of the CMOV algorithm proposed by Tsatsanis and Xu. We also introduce several methods to improve the performance of our introduced algorithm in the low SNR condition. Simulation results show the superior performance of our proposed methods.
Zhou, Guoxu; Yang, Zuyuan; Xie, Shengli; Yang, Jun-Mei
2011-04-01
Online blind source separation (BSS) is proposed to overcome the high computational cost problem, which limits the practical applications of traditional batch BSS algorithms. However, the existing online BSS methods are mainly used to separate independent or uncorrelated sources. Recently, nonnegative matrix factorization (NMF) shows great potential to separate the correlative sources, where some constraints are often imposed to overcome the non-uniqueness of the factorization. In this paper, an incremental NMF with volume constraint is derived and utilized for solving online BSS. The volume constraint to the mixing matrix enhances the identifiability of the sources, while the incremental learning mode reduces the computational cost. The proposed method takes advantage of the natural gradient based multiplication updating rule, and it performs especially well in the recovery of dependent sources. Simulations in BSS for dual-energy X-ray images, online encrypted speech signals, and high correlative face images show the validity of the proposed method.
ClinicalTrials.gov and Drugs@FDA: A comparison of results reporting for new drug approval trials
Schwartz, Lisa M.; Woloshin, Steven; Zheng, Eugene; Tse, Tony; Zarin, Deborah A.
2016-01-01
Background Pharmaceutical companies and other trial sponsors must submit certain trial results to ClinicalTrials.gov. The validity of these results is unclear. Purpose To validate results posted on ClinicalTrials.gov against publicly-available FDA reviews on Drugs@FDA. Data sources ClinicalTrials.gov (registry and results database) and Drugs@FDA (medical/statistical reviews). Study selection 100 parallel-group, randomized trials for new drug approvals (1/2013 – 7/2014) with results posted on ClinicalTrials.gov (3/15/2015). Data extraction Two assessors systematically extracted, and another verified, trial design, primary/secondary outcomes, adverse events, and deaths. Results The 100 trials were mostly phase 3 (90%) double-blind (92%), placebo-controlled (73%), representing 32 drugs from 24 companies. Of 137 primary outcomes from ClinicalTrials.gov, 134 (98%) had corresponding data in Drugs@FDA, 130 (95%) had concordant definitions, and 107 (78%) had concordant results; most differences were nominal (i.e. relative difference < 10%). Of 100 trials, primary outcome results in 14 could not be validated . Of 1,927 secondary outcomes from ClinicalTrials.gov, 1,061 (55%) definitions could be validated and 367 (19%) had results. Of 96 trials with ≥ 1 serious adverse event in either source, 14 could be compared and 7 were discordant. Of 62 trials with ≥ 1 death in either source, 25 could be compared and 17 were discordant. Limitations Unknown generalizability to uncontrolled or crossover trial results. Conclusion Primary outcome definitions and results were largely concordant between ClinicalTrials.gov and Drugs@FDA. Half of secondary outcomes could not be validated because Drugs@FDA only includes “key outcomes” for regulatory decision-making; nor could serious adverse events and deaths because Drugs@FDA frequently only includes results aggregated across multiple trials. PMID:27294570
Gallego, M T; Iraola, V; Himly, M; Robinson, D S; Badiola, C; García-Robaina, J C; Briza, P; Carnés, J
2010-01-01
Polymerised allergenic extracts (allergoids) are commonly used in allergen immunotherapy. Clinical efficacy and safety of these extracts have been demonstrated. Recently, allergen sequences have been identified by mass spectrometry in depigmented and polymerised (Dpg-Pol) extracts. The objectives of this study were to investigate the presence of allergens in Dpg-Pol extracts of house dust mite and to analyze the immunological changes induced by these extracts in asthmatic patients enrolled in a double-blind, placebo-controlled study. Dpg-Pol extracts were manufactured and vaccines with a composition of 50% Dermatophagoides pteronyssinus and 50% D. farinae (100 HEPL/ml) were prepared. Allergen composition was analyzed by mass spectrometry. Patients with asthma and rhinoconjunctivitis were treated in a 1-year, double-blind, placebo-controlled, parallel-group study with 6 up-dosing and monthly maintenance injections. Specific IgE and IgG4 titres to D. pteronyssinus, Der p 1 and Der p 2 were measured in patients' sera using the CAP system and direct ELISA experiments. Sequences from the major allergens Der p 1 and Der p 2 and from other allergens were identified in native and Dpg-Pol extracts. There was a statistically significant increase in specific IgG4, a decrease in the ratio of IgE/IgG4 to D. pteronyssinus and a significant increase in specific IgG4 to Der p 1 and Der p 2 in the patients allotted to active treatment. The detection of allergen sequences suggests preservation of major and minor allergens in Dpg-Pol allergoids from house dust mites. Efficacy in asthma treatment and the increase in specific IgG4 seem to be associated with the presence of major allergens in Dpg-Pol allergen extracts. Copyright (c) 2010 S. Karger AG, Basel.
Park, Dae-Myung; Kim, Seok-Hwan; Park, Yang-Chun; Kang, Wee-Chang; Lee, Sang-Ryong; Jung, In-Chul
2014-12-02
Gamisoyo-San (GSS) is a well-known Traditional Korean Medicine shown to be effective on mood disorders. The purpose of this research is to examine the effect of Gamisoyo-San on generalized anxiety disorder by its differently manufactured preparations. Multicenter, randomized, double-blinded, placebo-controlled study was set for 147 patients with generalized anxiety disorder recruited from November 1st 2009 to December 16th 2010. They were given Gamisoyo-San individual extract mixture (extraction done for each crude materia medica separately) or Gamisoyo-San multi-compound extract (extraction done for whole materia medica at once) or controlled medication. Hamilton Rating Scale for Anxiety (HAM-A), Korean State-Trait Anxiety Inventory (K-STAI), Penn State Worry Questionnaire (PSWQ), Korean Beck Depression Inventroy (K-BDI), Symptom Checklist-90-Revised (SCL-90-R), and Korean WHO Quality of Life Scale Abbreviated Version (WHOQOL-BREF) were evaluated. We also applied Pattern Identification tool for 'JingJi and ZhengChong (, Traditional Korean Medicine term which correlates with generalized anxiety disorder)' to patients to evaluate different responses among 9 patterns. HAM-A scores of Gamisoyo-San multi-compound extract group showed greater decrease compared to Gamisoyo-San individual extract mixture group and placebo group, but the difference was insignificant. WHOQOL-BREF scores of Gamisoyo-San multi-compound extract group showed significant increase compared to Gamisoyo-San individual extract mixture group and placebo group. In Heart blood deficiency pattern, the Gamisoyo-San multi-compound extract group showed significant decrease in K-BDI compared to the Gamisoyo-San individual extract mixture group. Gamisoyo-San did not improve anxiety level of GAD patients. However, it can be useful to improve quality of life, and reduce depressive, obsessive-compulsive, somatic symptoms of generalized anxiety disorder. Gamisoyo-San multi-compound seemed more effective than Gamisoyo-San individual extract mixture, especially in Heart blood deficiency pattern. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Kuriyan, Rebecca; Kumar, Divya R; R, Rajendran; Kurpad, Anura V
2010-06-17
Hibiscus sabdariffa is used regularly in folk medicine to treat various conditions. The study was a double blind, placebo controlled, randomized trial. Sixty subjects with serum LDL values in the range of 130-190 mg/dl and with no history of coronary heart disease were randomized into experimental and placebo groups. The experimental group received 1 gm of the extract for 90 days while the placebo received a similar amount of maltodextrin in addition to dietary and physical activity advice for the control of their blood lipids. Anthropometry, blood biochemistry, dietary and physical activity were assessed at baseline, day 45 and day 90. While body weight, serum LDL cholesterol and triglyceride levels decreased in both groups, there were no significant differences between the experimental and placebo group. It is likely that the observed effects were as a result of the patients following the standard dietary and physical activity advice. At a dose of 1 gm/day, hibiscus sabdariffa leaf extract did not appear to have a blood lipid lowering effect. REFCTRI2009000472.
Funding Sources for Visually Impaired Students in Higher Education.
ERIC Educational Resources Information Center
Traber, M.
1987-01-01
Financial aid sources available to visually handicapped students for postsecondary educational, vocational, or technical programs are outlined. Sources include national and state blindness agencies, colleges and universities, state vocational rehabilitation agencies, and the federal government. (Author/JDD)
Underdetermined blind separation of three-way fluorescence spectra of PAHs in water
NASA Astrophysics Data System (ADS)
Yang, Ruifang; Zhao, Nanjing; Xiao, Xue; Zhu, Wei; Chen, Yunan; Yin, Gaofang; Liu, Jianguo; Liu, Wenqing
2018-06-01
In this work, underdetermined blind decomposition method is developed to recognize individual components from the three-way fluorescent spectra of their mixtures by using sparse component analysis (SCA). The mixing matrix is estimated from the mixtures using fuzzy data clustering algorithm together with the scatters corresponding to local energy maximum value in the time-frequency domain, and the spectra of object components are recovered by pseudo inverse technique. As an example, using this method three and four pure components spectra can be blindly extracted from two samples of their mixture, with similarities between resolved and reference spectra all above 0.80. This work opens a new and effective path to realize monitoring PAHs in water by three-way fluorescence spectroscopy technique.
A Joint Optimization Criterion for Blind DS-CDMA Detection
NASA Astrophysics Data System (ADS)
Durán-Díaz, Iván; Cruces-Alvarez, Sergio A.
2006-12-01
This paper addresses the problem of the blind detection of a desired user in an asynchronous DS-CDMA communications system with multipath propagation channels. Starting from the inverse filter criterion introduced by Tugnait and Li in 2001, we propose to tackle the problem in the context of the blind signal extraction methods for ICA. In order to improve the performance of the detector, we present a criterion based on the joint optimization of several higher-order statistics of the outputs. An algorithm that optimizes the proposed criterion is described, and its improved performance and robustness with respect to the near-far problem are corroborated through simulations. Additionally, a simulation using measurements on a real software-radio platform at 5 GHz has also been performed.
Additions to Bibliography: Education of Deaf-Blind, Fall 1972-June 1974.
ERIC Educational Resources Information Center
Perkins School for the Blind, Watertown, MA.
The bibliography lists 134 sources of information on education of the deaf-blind including journal articles, books, workshop and conference proceedings, bibliographies, films, and tapes. Entries are grouped under general topics such as parents, family and community; medical neurological management and concerns; educational evaluation and testing;…
Selected Annotated Bibliography of Deaf-Blind Prevocational Training Literature.
ERIC Educational Resources Information Center
Stoddard, Denis W.; Glazer, Jamie
Presented is an annotated bibliography of 47 documents relating to prevocational training of deaf-blind children. Entries include books, journal articles, conference proceedings, and regional center reports and usually provide information on author, title, source, publication date, and a review (including a brief description of the type and…
Trends in the Prevalence Rates and Numbers of Blind and Visually Impaired Schoolchildren.
ERIC Educational Resources Information Center
Kirchner, C.
1990-01-01
This paper draws on primary and secondary data sources to document an increasing number of visually handicapped children. The paper discusses socioeconomic trends, increased rates of handicapping conditions in general, increased number of legally blind schoolchildren, and evidence of an increase in retinopathy of prematurity. (JDD)
Deaf-Blindness: National Organizations and Resources. Reference Circular No. 93-1.
ERIC Educational Resources Information Center
Library of Congress, Washington, DC. National Library Service for the Blind and Physically Handicapped.
This circular lists national organizations and print and audiovisual resources on areas of service to persons with deaf blindness, including rehabilitation, education, information and referral, recreation, and sources for adaptive devices and products. Section I is an alphabetical list of 40 national organizations and resources, including…
Data fusion for improved camera-based detection of respiration in neonates
NASA Astrophysics Data System (ADS)
Jorge, João.; Villarroel, Mauricio; Chaichulee, Sitthichok; McCormick, Kenny; Tarassenko, Lionel
2018-02-01
Monitoring respiration during neonatal sleep is notoriously difficult due to the nonstationary nature of the signals and the presence of spurious noise. Current approaches rely on the use of adhesive sensors, which can damage the fragile skin of premature infants. Recently, non-contact methods using low-cost RGB cameras have been proposed to acquire this vital sign from (a) motion or (b) photoplethysmographic signals extracted from the video recordings. Recent developments in deep learning have yielded robust methods for subject detection in video data. In the analysis described here, we present a novel technique for combining respiratory information from high-level visual descriptors provided by a multi-task convolutional neural network. Using blind source separation, we find the combination of signals which best suppresses pulse and motion distortions and subsequently use this to extract a respiratory signal. Evaluation results were obtained from recordings on 5 neonatal patients nursed in the Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital, Oxford, UK. We compared respiratory rates derived from this fused breathing signal against those measured using the gold standard provided by the attending clinical staff. We show that respiratory rate (RR) be accurately estimated over the entire range of respiratory frequencies.
Forbes, C. D.; Barr, R. D.; Reid, G.; Thomson, C.; Prentice, C. R. M.; Nicol, G. P. Mc; Douglas, A. S.
1972-01-01
In a double-blind trial tranexamic acid (AMCA, Cyclokapron), 1 g three times a day for five days, significantly reduced blood loss and transfusion requirements after dental extraction in patients with haemophilia and Christmas disease. No side effects were seen in either group of patients. Screening tests showed no toxic action of tranexamic acid on the liver, kidney, or heart. PMID:4553818
Choi, Sun Young; Hong, Ji Yeon; Ko, Eun Jung; Kim, Beom Joon; Hong, Sung-Woon; Lim, Mi Hyoung; Yeon, Sung Hum; Son, Rak Ho
2018-02-01
Oxidative stress and photodamage resulting from ultraviolet radiation exposure play key roles in skin aging. Fermented Cyclopia intermedia, which is used to brew honeybush tea, exerts antioxidant and anti-wrinkle effects by inhibiting reactive oxygen species production and downregulating matrix metalloproteinase activity. This randomized, double-blinded, placebo-controlled study aimed to evaluate the efficacy and safety of fermented honeybush (Cyclopia intermedia) extract (HU-018) for skin rejuvenation. 120 Korean subjects with crow's feet wrinkles were randomized to receive either low-dose extract (400 mg/day), high-dose extract (800 mg/day), or placebo (negative control, only dextran) for 12 weeks. Wrinkles were evaluated using JANUS ® and PRIMO pico ® . Skin elasticity, hydration and transepidermal water loss were measured. Global skin wrinkle grade was significantly improved in both low-dose and high-dose groups compared to placebo group, as well as for skin hydration and elasticity. Both the low- and high-dose groups showed significantly decreased TEWL compared to the placebo group. There were no adverse effects during the entire study period. Our data indicate that HU-018 is effective for improving skin wrinkles, elasticity, and hydration. Therefore, daily supplementation with fermented honeybush could be helpful for protecting against skin aging.
de la Barrera-Núñez, María C.; Yáñez-Vico, Rosa M.; Batista-Cruzado, Antonio; Heurtebise-Saavedra, Jean M.; Castillo-de Oyagüe, Raquel
2014-01-01
Objectives: To evaluate the anti-inflammatory and analgesic effect of Bromelain (pineapple extract) administered orally in the postoperative after extraction of impacted lower molars. Study Design: This is a prospective, placebo-controlled, unicentric, double-blind study; the sample size was 34 patients. The pre and postoperative outcomes, evaluated on the third (D3) and eighth day (D8), included inflamtion, pain and oral aperture, as well as the need for analgesics. One group received bromelain 150mg per day for three days and 100mg on days 4 to 7. The other group received placebo in the same dosage. All outcomes werrecorded quantitatively and analyzed with the Mann-Whitney U test for independent samples. Results: Although there were no statistically significant differences between the treatment groups, a trend towards less inflammation and improved oral aperture was observed in the group that received bromelain, compared to the group that received placebo. This trend can be attributed completely to random reasons, since there is no statistical difference in the results. Conclusions: Further studies are necessary to analyze different administration patterns and doses of bromelain for the use in the postoperative of impacted third molars. Key words:Tooth extraction, third molar, postoperative period, bromeline, clinical study. PMID:24316697
NASA Astrophysics Data System (ADS)
Pudjonarko, Dwi; Retnaningsih; Abidin, Zainal
2018-02-01
Background: Levels of arginine associated with clinical outcome in acute ischemic stroke (AIS). Arginine is a protein needed to synthesis nitric oxide (NO), a potential vasodilator and antioxidant. Snakehead fish is a source of protein which has antioxidant activity. Snakehead fish contains mineral, vitamin, and amino acids. One of the amino acids that were found quite high in snakehead fish extract is arginine. The aim of this study was done to determine the effect of snakehead fish extracts (SFE) on serum arginin levels and clinical outcome of AIS patients. Methods: It was double-blind randomized pretest-posttest control group design, with. AIS patients were divided into two groups i.e. snakehead fish extracts (SFE) and control. SFE group were administered 15 grams SFE for 7 days . Arginine serum levels and clinical outcome (measured by National Institute of Health Stroke Scale = NIHSS) were measured before and after treatment, other related factors were also analyzed in Logistic regression. Results: A total of 42 subjects who were performed random allocation as SFE or control group. There was no differences in subject characteristics between the two groups. There was a differences Δ arginine serum levels between SFE and control (33.6±19.95 μmol/L 0.3±2.51 μmol/L p<0.001). Change in NIHSS score in SFE improved significantly compared to the control group (4.14 ± 2.03; 2.52 ± 1.81;p=0.009 ). Logistic regression analysis showed only female gender factor that affected on improvement of NIHSS (OR=7; p=0,01). Conclusion: There is Clinical outcome improvement and enhancement of arginine serum levels in AIS patient with snakehead fish extract supplementation.
Sastre, J; Lluch-Bernal, M; Quirce, S; Arrieta, I; Lahoz, C; Del Amo, A; Fernández-Caldas, E; Marañón, F
2000-06-01
The third-stage larvae of Anisakis simplex may be a hidden source of allergens in fish. The objective was to determine whether the ingestion of lyophilized A. simplex larvae, or antigen, induces clinical symptoms in a group of A. simplex-sensitized patients. Double-blind, placebo-controlled oral challenges were conducted in 11 individuals who had experienced allergic reactions after eating fish. Another patient had chronic urticaria unrelated to the ingestion of fish. All patients had positive skin tests and specific IgE determinations for A. simplex and negative skin tests to a battery of fish species. Conjunctival tests with A. simplex extracts were conducted in all patients and in five controls. The 12 patients received capsules containing either lactose or one, five, or 25 lyophilized larvae of A. simplex at 2-h intervals in a double-blind fashion. The highest single dose was 100 larvae. ECP and tryptase levels in serum were measured before and after the last oral challenge. Lyophilized antigen was also given to five patients. None of the 12 patients experienced a positive reaction after the ingestion of the placebo, the lyophilized larvae, or the antigen. Tryptase and ECP levels before and after challenges did not change significantly. Conjunctival provocation tests were positive in 11 out of the 12 patients and in none of the controls. The ingestion of 100 lyophilized A. simplex larvae, or its equivalent in antigen, does not induce clinical symptoms in individuals with a clinical history and laboratory findings of hypersensitivity to A. simplex. The data suggest that only the ingestion of live larvae may be capable of inducing allergic manifestations.
NASA Astrophysics Data System (ADS)
Aasi, J.; Abadie, J.; Abbott, B. P.; Abbott, R.; Abbott, T. D.; Abernathy, M.; Accadia, T.; Acernese, F.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Ajith, P.; Allen, B.; Allocca, A.; Amador Ceron, E.; Amariutei, D.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Ast, S.; Aston, S. M.; Astone, P.; Atkinson, D.; Aufmuth, P.; Aulbert, C.; Aylott, B. E.; Babak, S.; Baker, P.; Ballardin, G.; Ballmer, S.; Bao, Y.; Barayoga, J. C. B.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barton, M. A.; Bartos, I.; Bassiri, R.; Bastarrika, M.; Basti, A.; Batch, J.; Bauchrowitz, J.; Bauer, Th. S.; Bebronne, M.; Beck, D.; Behnke, B.; Bejger, M.; Beker, M. G.; Bell, A. S.; Bell, C.; Belopolski, I.; Benacquista, M.; Berliner, J. M.; Bertolini, A.; Betzwieser, J.; Beveridge, N.; Beyersdorf, P. T.; Bhadbade, T.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Biswas, R.; Bitossi, M.; Bizouard, M. A.; Black, E.; Blackburn, J. K.; Blackburn, L.; Blair, D.; Bland, B.; Blom, M.; Bock, O.; Bodiya, T. P.; Bogan, C.; Bond, C.; Bondarescu, R.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Boschi, V.; Bose, S.; Bosi, L.; Bouhou, B.; Braccini, S.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Breyer, J.; Briant, T.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Britzger, M.; Brooks, A. F.; Brown, D. A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Burguet–Castell, J.; Buskulic, D.; Buy, C.; Byer, R. L.; Cadonati, L.; Cagnoli, G.; Calloni, E.; Camp, J. B.; Campsie, P.; Cannon, K.; Canuel, B.; Cao, J.; Capano, C. D.; Carbognani, F.; Carbone, L.; Caride, S.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C.; Cesarini, E.; Chalermsongsak, T.; Charlton, P.; Chassande-Mottin, E.; Chen, W.; Chen, X.; Chen, Y.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Chow, J.; Christensen, N.; Chua, S. S. Y.; Chung, C. T. Y.; Chung, S.; Ciani, G.; Clara, F.; Clark, D. E.; Clark, J. A.; Clayton, J. H.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colacino, C. N.; Colla, A.; Colombini, M.; Conte, A.; Conte, R.; Cook, D.; Corbitt, T. R.; Cordier, M.; Cornish, N.; Corsi, A.; Costa, C. A.; Coughlin, M.; Coulon, J.-P.; Couvares, P.; Coward, D. M.; Cowart, M.; Coyne, D. C.; Creighton, J. D. E.; Creighton, T. D.; Cruise, A. M.; Cumming, A.; Cunningham, L.; Cuoco, E.; Cutler, R. M.; Dahl, K.; Damjanic, M.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dattilo, V.; Daudert, B.; Daveloza, H.; Davier, M.; Daw, E. J.; Dayanga, T.; De Rosa, R.; DeBra, D.; Debreczeni, G.; Degallaix, J.; Del Pozzo, W.; Dent, T.; Dergachev, V.; DeRosa, R.; Dhurandhar, S.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Di Paolo Emilio, M.; Di Virgilio, A.; Díaz, M.; Dietz, A.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dorsher, S.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Du, Z.; Dumas, J.-C.; Dwyer, S.; Eberle, T.; Edgar, M.; Edwards, M.; Effler, A.; Ehrens, P.; Endrőczi, G.; Engel, R.; Etzel, T.; Evans, K.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Farr, B. F.; Farr, W. M.; Favata, M.; Fazi, D.; Fehrmann, H.; Feldbaum, D.; Feroz, F.; Ferrante, I.; Ferrini, F.; Fidecaro, F.; Finn, L. S.; Fiori, I.; Fisher, R. P.; Flaminio, R.; Foley, S.; Forsi, E.; Forte, L. A.; Fotopoulos, N.; Fournier, J.-D.; Franc, J.; Franco, S.; Frasca, S.; Frasconi, F.; Frede, M.; Frei, M. A.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Friedrich, D.; Fritschel, P.; Frolov, V. V.; Fujimoto, M.-K.; Fulda, P. J.; Fyffe, M.; Gair, J.; Galimberti, M.; Gammaitoni, L.; Garcia, J.; Garufi, F.; Gáspár, M. E.; Gelencser, G.; Gemme, G.; Genin, E.; Gennai, A.; Gergely, L. Á.; Ghosh, S.; Giaime, J. A.; Giampanis, S.; Giardina, K. D.; Giazotto, A.; Gil-Casanova, S.; Gill, C.; Gleason, J.; Goetz, E.; González, G.; Gorodetsky, M. L.; Goßler, S.; Gouaty, R.; Graef, C.; Graff, P. B.; Granata, M.; Grant, A.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Griffo, C.; Grote, H.; Grover, K.; Grunewald, S.; Guidi, G. M.; Guido, C.; Gupta, R.; Gustafson, E. K.; Gustafson, R.; Hallam, J. M.; Hammer, D.; Hammond, G.; Hanks, J.; Hanna, C.; Hanson, J.; Harms, J.; Harry, G. M.; Harry, I. W.; Harstad, E. D.; Hartman, M. T.; Haster, C.-J.; Haughian, K.; Hayama, K.; Hayau, J.-F.; Heefner, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M. A.; Heng, I. S.; Heptonstall, A. W.; Herrera, V.; Heurs, M.; Hewitson, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Holt, K.; Holtrop, M.; Hong, T.; Hooper, S.; Hough, J.; Howell, E. J.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Ingram, D. R.; Inta, R.; Isogai, T.; Ivanov, A.; Izumi, K.; Jacobson, M.; James, E.; Jang, Y. J.; Jaranowski, P.; Jesse, E.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Kalmus, P.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kasprzack, M.; Kasturi, R.; Katsavounidis, E.; Katzman, W.; Kaufer, H.; Kaufman, K.; Kawabe, K.; Kawamura, S.; Kawazoe, F.; Keitel, D.; Kelley, D.; Kells, W.; Keppel, D. G.; Keresztes, Z.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, B. K.; Kim, C.; Kim, H.; Kim, K.; Kim, N.; Kim, Y. M.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kline, J.; Kokeyama, K.; Kondrashov, V.; Koranda, S.; Korth, W. Z.; Kowalska, I.; Kozak, D.; Kringel, V.; Krishnan, B.; Królak, A.; Kuehn, G.; Kumar, P.; Kumar, R.; Kurdyumov, R.; Kwee, P.; Lam, P. K.; Landry, M.; Langley, A.; Lantz, B.; Lastzka, N.; Lawrie, C.; Lazzarini, A.; Le Roux, A.; Leaci, P.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Leong, J. R.; Leonor, I.; Leroy, N.; Letendre, N.; Lhuillier, V.; Li, J.; Li, T. G. F.; Lindquist, P. E.; Litvine, V.; Liu, Y.; Liu, Z.; Lockerbie, N. A.; Lodhia, D.; Logue, J.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J.; Lubinski, M.; Lück, H.; Lundgren, A. P.; Macarthur, J.; Macdonald, E.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Mageswaran, M.; Mailand, K.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandel, I.; Mandic, V.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A.; Maros, E.; Marque, J.; Martelli, F.; Martin, I. W.; Martin, R. M.; Marx, J. N.; Mason, K.; Masserot, A.; Matichard, F.; Matone, L.; Matzner, R. A.; Mavalvala, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McGuire, S. C.; McIntyre, G.; McIver, J.; Meadors, G. D.; Mehmet, M.; Meier, T.; Melatos, A.; Melissinos, A. C.; Mendell, G.; Menéndez, D. F.; Mercer, R. A.; Meshkov, S.; Messenger, C.; Meyer, M. S.; Miao, H.; Michel, C.; Milano, L.; Miller, J.; Minenkov, Y.; Mingarelli, C. M. F.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Mohan, M.; Mohapatra, S. R. P.; Moraru, D.; Moreno, G.; Morgado, N.; Morgia, A.; Mori, T.; Morriss, S. R.; Mosca, S.; Mossavi, K.; Mours, B.; Mow–Lowry, C. M.; Mueller, C. L.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Müller-Ebhardt, H.; Munch, J.; Murphy, D.; Murray, P. G.; Mytidis, A.; Nash, T.; Naticchioni, L.; Necula, V.; Nelson, J.; Neri, I.; Newton, G.; Nguyen, T.; Nishizawa, A.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E.; Nuttall, L.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Oldenberg, R. G.; O'Reilly, B.; O'Shaughnessy, R.; Osthelder, C.; Ott, C. D.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Page, A.; Palladino, L.; Palomba, C.; Pan, Y.; Pankow, C.; Paoletti, F.; Paoletti, R.; Papa, M. A.; Parisi, M.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Pedraza, M.; Penn, S.; Perreca, A.; Persichetti, G.; Phelps, M.; Pichot, M.; Pickenpack, M.; Piergiovanni, F.; Pierro, V.; Pihlaja, M.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Pletsch, H. J.; Plissi, M. V.; Poggiani, R.; Pöld, J.; Postiglione, F.; Poux, C.; Prato, M.; Predoi, V.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Quetschke, V.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Rakhmanov, M.; Ramet, C.; Rankins, B.; Rapagnani, P.; Raymond, V.; Re, V.; Reed, C. M.; Reed, T.; Regimbau, T.; Reid, S.; Reitze, D. H.; Ricci, F.; Riesen, R.; Riles, K.; Roberts, M.; Robertson, N. A.; Robinet, F.; Robinson, C.; Robinson, E. L.; Rocchi, A.; Roddy, S.; Rodriguez, C.; Rodruck, M.; Rolland, L.; Rollins, J. G.; Romano, R.; Romie, J. H.; Rosińska, D.; Röver, C.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Salemi, F.; Sammut, L.; Sandberg, V.; Sankar, S.; Sannibale, V.; Santamaría, L.; Santiago-Prieto, I.; Santostasi, G.; Saracco, E.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Savage, R. L.; Schilling, R.; Schnabel, R.; Schofield, R. M. S.; Schulz, B.; Schutz, B. F.; Schwinberg, P.; Scott, J.; Scott, S. M.; Seifert, F.; Sellers, D.; Sentenac, D.; Sergeev, A.; Shaddock, D. A.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sidery, T. L.; Siemens, X.; Sigg, D.; Simakov, D.; Singer, A.; Singer, L.; Sintes, A. M.; Skelton, G. R.; Slagmolen, B. J. J.; Slutsky, J.; Smith, J. R.; Smith, M. R.; Smith, R. J. E.; Smith-Lefebvre, N. D.; Somiya, K.; Sorazu, B.; Speirits, F. C.; Sperandio, L.; Stefszky, M.; Steinert, E.; Steinlechner, J.; Steinlechner, S.; Steplewski, S.; Stochino, A.; Stone, R.; Strain, K. A.; Strigin, S. E.; Stroeer, A. S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sung, M.; Susmithan, S.; Sutton, P. J.; Swinkels, B.; Szeifert, G.; Tacca, M.; Taffarello, L.; Talukder, D.; Tanner, D. B.; Tarabrin, S. P.; Taylor, R.; ter Braack, A. P. M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Thüring, A.; Titsler, C.; Tokmakov, K. V.; Tomlinson, C.; Toncelli, A.; Tonelli, M.; Torre, O.; Torres, C. V.; Torrie, C. I.; Tournefier, E.; Travasso, F.; Traylor, G.; Tse, M.; Ugolini, D.; Vahlbruch, H.; Vajente, G.; van den Brand, J. F. J.; Van Den Broeck, C.; van der Putten, S.; van Veggel, A. A.; Vass, S.; Vasuth, M.; Vaulin, R.; Vavoulidis, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Vetrano, F.; Viceré, A.; Villar, A. E.; Vinet, J.-Y.; Vitale, S.; Vocca, H.; Vorvick, C.; Vyatchanin, S. P.; Wade, A.; Wade, L.; Wade, M.; Waldman, S. J.; Wallace, L.; Wan, Y.; Wang, M.; Wang, X.; Wanner, A.; Ward, R. L.; Was, M.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.; Wessels, P.; West, M.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D. J.; Whiting, B. F.; Wiesner, K.; Wilkinson, C.; Willems, P. A.; Williams, L.; Williams, R.; Willke, B.; Wimmer, M.; Winkelmann, L.; Winkler, W.; Wipf, C. C.; Wiseman, A. G.; Wittel, H.; Woan, G.; Wooley, R.; Worden, J.; Yablon, J.; Yakushin, I.; Yamamoto, H.; Yamamoto, K.; Yancey, C. C.; Yang, H.; Yeaton-Massey, D.; Yoshida, S.; Yvert, M.; Zadrożny, A.; Zanolin, M.; Zendri, J.-P.; Zhang, F.; Zhang, L.; Zhao, C.; Zotov, N.; Zucker, M. E.; Zweizig, J.
2013-09-01
Compact binary systems with neutron stars or black holes are one of the most promising sources for ground-based gravitational-wave detectors. Gravitational radiation encodes rich information about source physics; thus parameter estimation and model selection are crucial analysis steps for any detection candidate events. Detailed models of the anticipated waveforms enable inference on several parameters, such as component masses, spins, sky location and distance, that are essential for new astrophysical studies of these sources. However, accurate measurements of these parameters and discrimination of models describing the underlying physics are complicated by artifacts in the data, uncertainties in the waveform models and in the calibration of the detectors. Here we report such measurements on a selection of simulated signals added either in hardware or software to the data collected by the two LIGO instruments and the Virgo detector during their most recent joint science run, including a “blind injection” where the signal was not initially revealed to the collaboration. We exemplify the ability to extract information about the source physics on signals that cover the neutron-star and black-hole binary parameter space over the component mass range 1M⊙-25M⊙ and the full range of spin parameters. The cases reported in this study provide a snapshot of the status of parameter estimation in preparation for the operation of advanced detectors.
Disturbance Source Separation in Shear Flows Using Blind Source Separation Methods
NASA Astrophysics Data System (ADS)
Gluzman, Igal; Cohen, Jacob; Oshman, Yaakov
2017-11-01
A novel approach is presented for identifying disturbance sources in wall-bounded shear flows. The method can prove useful for active control of boundary layer transition from laminar to turbulent flow. The underlying idea is to consider the flow state, as measured in sensors, to be a mixture of sources, and to use Blind Source Separation (BSS) techniques to recover the separate sources and their unknown mixing process. We present a BSS method based on the Degenerate Unmixing Estimation Technique. This method can be used to identify any (a priori unknown) number of sources by using the data acquired by only two sensors. The power of the new method is demonstrated via numerical and experimental proofs of concept. Wind tunnel experiments involving boundary layer flow over a flat plate were carried out, in which two hot-wire anemometers were used to separate disturbances generated by disturbance generators such as a single dielectric barrier discharge plasma actuator and a loudspeaker.
Jasmine rice panicle: A safe and efficient natural ingredient for skin aging treatments.
Kanlayavattanakul, Mayuree; Lourith, Nattaya; Chaikul, Puxvadee
2016-12-04
While rice is one of the most important global staple food sources its extracts have found many uses as the bases of herbal remedies. Rice extracts contain high levels of phenolic compounds which are known to be bioactive, some of which show cutaneous benefits and activity towards skin disorders. This study highlights an assessment of the cellular activity and clinical efficacy of rice panicle extract, providing necessary information relevant to the development of new cosmetic products. Jasmine rice panicle extract was standardized, and the level of phenolics present was determined. In vitro anti-aging, and extract activity towards melanogenesis was conducted in B16F10 melanoma cells, and antioxidant activity was assessed in human skin fibroblast cell cultures. Topical product creams containing the extract were developed, and skin irritation testing using a single application closed patch test method was done using 20 Thai volunteers. Randomized double-blind, placebo-controlled efficacy evaluation was undertaken in 24 volunteers over an 84d period, with the results monitored by Corneometer ® CM 825, Cutometer ® MPA 580, Mexameter ® MX 18 and Visioscan ® VC 98. Jasmine rice panicle extract was shown to have a high content of p-coumaric, ferulic and caffeic acids, and was not cytotoxic to the cell lines used in this study. Cells treated with extract suppressed melanogenesis via tyrosinase and TRP-2 inhibitory effects, which protect the cell from oxidative stress at doses of 0.1mg/ml or lower. The jasmine rice panicle preparations (0.1-0.2%) were safe (MII=0), and significantly (p<0.05) increased skin hydration levels relative to baseline. Skin lightening, and anti-wrinkle effects related to skin firmness and smoothness were observed, in addition to a reduction in skin wrinkling. Improvements in skin biophysics of both 0.1% and 0.2% extracts were showed to be comparable (p>0.05). Jasmine rice panicle extract having high levels of phenolics shows cutaneous benefits as the basis for skin aging treatments, as indicated through in vitro cytotoxicity assessments and skin testing in human subjects. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Hintze, A; Paessler, L
2006-06-01
A randomised double-blind study investigated 155 patients with tooth extractions in the mandibular and maxillary jaws for a loss of anaesthetic potency when reducing the concentration of the active in articaine solutions. Tests were performed on the preparations of articaine 4% with a 1:200,000 addition of epinephrine (Ultracain D-S) and articaine 2% with a 1:200,000 addition of epinephrine (Ultracain 2%-Suprarenin). Local infiltration anaesthesia was the chosen method of anaesthesia. The most noticeable difference observed between the two injection solutions concerned the duration of anaesthesia, which was significantly shortened under the low-dose solution. The 4% articaine solution did not prove superior in local anaesthetic effect. Articaine 2% with epinephrine 1:200,000, therefore, can be considered a suitable local anaesthetic for tooth extractions.
Leuchtgens, H
1993-07-20
In 30 patients with stage NYHA II cardiac insufficiency, a placebo-controlled randomized double-blind study was carried out to determine the efficacy of the Crataegus special extract WS 1442. Treatment duration was 8 weeks, and the substance was administered at a dose of 1 capsule taken twice a day. The main target parameters were alteration in the pressure-x-rate product (PRP) under standardised loading on a bicycle ergometer, and a score of subjective improvement of complaints elicited by a questionnaire. Secondary parameters were exercise tolerance and the change in heart rate and arterial blood pressure. The active substance group showed a statistically significant advantage over placebo in terms of changes in PRP (at a load of 50 W) and the score, but also in the secondary parameter heart rate. In both groups, systolic and diastolic blood pressure was mildly reduced. No adverse reactions occurred.
López-Pacheco, María G; Sánchez-Fernández, Luis P; Molina-Lozano, Herón
2014-01-15
Noise levels of common sources such as vehicles, whistles, sirens, car horns and crowd sounds are mixed in urban soundscapes. Nowadays, environmental acoustic analysis is performed based on mixture signals recorded by monitoring systems. These mixed signals make it difficult for individual analysis which is useful in taking actions to reduce and control environmental noise. This paper aims at separating, individually, the noise source from recorded mixtures in order to evaluate the noise level of each estimated source. A method based on blind deconvolution and blind source separation in the wavelet domain is proposed. This approach provides a basis to improve results obtained in monitoring and analysis of common noise sources in urban areas. The method validation is through experiments based on knowledge of the predominant noise sources in urban soundscapes. Actual recordings of common noise sources are used to acquire mixture signals using a microphone array in semi-controlled environments. The developed method has demonstrated great performance improvements in identification, analysis and evaluation of common urban sources. © 2013 Elsevier B.V. All rights reserved.
Four different ways of philanthropic aid to the blind in medieval eastern Christendom.
Diamandopoulou-Drummond, A H; Diamandopoulos, A A; Marketos, S G
1995-11-01
The care of the blind, either as medical treatment or as divine therapy, has probably been the most ancient form of help for ill people. However, it was during the Byzantine Empire (325-1453 AD) that the state organized a 'blindness relief' plan as part of a widespread public health system. Our sources for the subject include medical writings, state decrees, Saint's 'vitae' and representations of relevant works of art. Based on the above data we classify the health care for the blind in Byzantium as: (a) support of ophthalmological education as evidenced by an abundance of medical writings on the subject; (b) establishment of charitable institutions exclusively or partially for the blind, where there was not only medical care but also provision for a wide range of social aid - the most advanced being specially trained escorts for each blind person; and (c) support by the state of an extended chain of religious institutions where miraculous help for the blind was promised. We conclude that the public health policy in Byzantium made adequate and very early provision for the blind.
Spontaneous facial expressions of emotion of congenitally and noncongenitally blind individuals.
Matsumoto, David; Willingham, Bob
2009-01-01
The study of the spontaneous expressions of blind individuals offers a unique opportunity to understand basic processes concerning the emergence and source of facial expressions of emotion. In this study, the authors compared the expressions of congenitally and noncongenitally blind athletes in the 2004 Paralympic Games with each other and with those produced by sighted athletes in the 2004 Olympic Games. The authors also examined how expressions change from 1 context to another. There were no differences between congenitally blind, noncongenitally blind, and sighted athletes, either on the level of individual facial actions or in facial emotion configurations. Blind athletes did produce more overall facial activity, but these were isolated to head and eye movements. The blind athletes' expressions differentiated whether they had won or lost a medal match at 3 different points in time, and there were no cultural differences in expression. These findings provide compelling evidence that the production of spontaneous facial expressions of emotion is not dependent on observational learning but simultaneously demonstrates a learned component to the social management of expressions, even among blind individuals.
A blind search for a common signal in gravitational wave detectors
NASA Astrophysics Data System (ADS)
Liu, Hao; Creswell, James; von Hausegger, Sebastian; Jackson, Andrew D.; Naselsky, Pavel
2018-02-01
We propose a blind, template-free method for the extraction of a common signal between the Hanford and Livingston detectors and apply it especially to the GW150914 event. We construct a log-likelihood method that maximizes the cross-correlation between each detector and the common signal and minimizes the cross-correlation between the residuals. The reliability of this method is tested using simulations with an injected common signal. Finally, our method is used to assess the quality of theoretical gravitational wave templates for GW150914.
Secure detection in quantum key distribution by real-time calibration of receiver
NASA Astrophysics Data System (ADS)
Marøy, Øystein; Makarov, Vadim; Skaar, Johannes
2017-12-01
The single-photon detectionefficiency of the detector unit is crucial for the security of common quantum key distribution protocols like Bennett-Brassard 1984 (BB84). A low value for the efficiency indicates a possible eavesdropping attack that exploits the photon receiver’s imperfections. We present a method for estimating the detection efficiency, and calculate the corresponding secure key generation rate. The estimation is done by testing gated detectors using a randomly activated photon source inside the receiver unit. This estimate gives a secure rate for any detector with non-unity single-photon detection efficiency, both inherit or due to blinding. By adding extra optical components to the receiver, we make sure that the key is extracted from photon states for which our estimate is valid. The result is a quantum key distribution scheme that is secure against any attack that exploits detector imperfections.
Custom FPGA processing for real-time fetal ECG extraction and identification.
Torti, E; Koliopoulos, D; Matraxia, M; Danese, G; Leporati, F
2017-01-01
Monitoring the fetal cardiac activity during pregnancy is of crucial importance for evaluating fetus health. However, there is a lack of automatic and reliable methods for Fetal ECG (FECG) monitoring that can perform this elaboration in real-time. In this paper, we present a hardware architecture, implemented on the Altera Stratix V FPGA, capable of separating the FECG from the maternal ECG and to correctly identify it. We evaluated our system using both synthetic and real tracks acquired from patients beyond the 20th pregnancy week. This work is part of a project aiming at developing a portable system for FECG continuous real-time monitoring. Its characteristics of reduced power consumption, real-time processing capability and reduced size make it suitable to be embedded in the overall system, that is the first proposed exploiting Blind Source Separation with this technology, to the best of our knowledge. Copyright © 2016 Elsevier Ltd. All rights reserved.
Sugihara, Yoshihiko; Ikushima, Shigehito; Miyake, Mika; Kirisako, Takayoshi; Yada, Yukihiro; Fujiwara, Daisuke
2018-01-01
Purpose The present study examined the effect of ingestion of Koji extract containing 14-dehydroergosterol (14-DHE), prepared from Aspergillus kawachii NBRC4308, on improvement of skin conditions among healthy volunteers. Subjects and methods In a randomized, double-blind, placebo-controlled, parallel-group study, 70 healthy adult women who felt that their skin was dry ingested either a placebo dietary supplement or Koji extract (200 mg/day) supplement containing 0.1% 14-DHE for 12 weeks. Throughout the treatment period and for 4 weeks afterward, objective indicators – including moisture content of the stratum corneum, trans-epidermal water loss (TEWL), and skin wrinkles – were evaluated; in addition, the subjects answered a questionnaire on their skin conditions with ratings on a visual analog scale. Statistical analysis was conducted on the basis of differences from baseline scores. Results Compared with the placebo group, the Koji extract group showed significantly increased forearm moisture at 4, 8, and 16 weeks (p < 0.05 on unpaired t-test). The questionnaire survey showed a marked improvement in skin conditions, particularly crow’s feet, in the Koji extract group versus the placebo group at 8 weeks (p < 0.05 by unpaired t-test). Furthermore, the Koji extract group showed a trend (p < 0.10) toward improvement in skin moisture (at 4 weeks), dryness around the eyes/mouth (at 4 weeks), and overall skin condition (at 8 weeks) versus the placebo group. Conclusion Ingestion of Koji extract containing 14-DHE was demonstrated to have positive effects toward improving skin conditions – in particular, on increasing skin moisture in the stratum corneum. PMID:29563825
Teaching Oral-Aural Communication Skills in a Rehabilitation Center for the Blind
ERIC Educational Resources Information Center
Leavitt, Glenn
1973-01-01
Oral-aural communication skills, which are sequentially taught in 1-hour classes to three or four students at the Michigan Rehabilitation Center for the Blind, include audition, conversation, use of playback-recording devices, techniques of aural reading, and techniques for learning sources of recorded reading materials. (Author/MC)
Variability in Stepping Direction Explains the Veering Behavior of Blind Walkers
ERIC Educational Resources Information Center
Kallie, Christopher S.; Schrater, Paul R.; Legge, Gordon E.
2007-01-01
Walking without vision results in veering, an inability to maintain a straight path that has important consequences for blind pedestrians. In this study, the authors addressed whether the source of veering in the absence of visual and auditory feedback is better attributed to errors in perceptual encoding or undetected motor error. Three…
Zhong, Yisheng; Xiang, Minhong; Ye, Wen; Cheng, Yu; Jiang, Youqin
2010-01-01
To evaluate the visual field protective effect of Erigeron breviscapus (vant.) Hand. Mazz. (EBHM) extract on glaucoma with controlled intraocular pressure (IOP). Forty patients (40 eyes) with primary open-angle glaucoma, visual field defects and a postsurgical IOP of <18 mmHg were enrolled. The EBHM and placebo tablets were given orally according to the randomized and double-blind principle. Two tablets (of either EBHM or placebo) were taken three times a day for a period of 6 months. Patients were examined every 2 months after treatment commenced. At the end of the study, the results were given to the drug manufacturer. All patients completed the prospective, randomized, double-blind, clinical trial. No obvious adverse effects were found in patients during the treatment period. In the placebo group, no significant difference was found in mean defect (MD) or mean sensitivity (MS) between the values at pre-treatment and after 2, 4, and 6 months of treatment. After 6 months of EBHM treatment, the MD was significantly decreased and the MS was significantly increased compared with pre-treatment (p < 0.05). In the patients with moderate and late glaucoma, the MD was significantly decreased and the MS was significantly increased after 2, 4, and 6 months of EBHM treatment compared with pre-treatment. EBHM extract may have a partial protective effect on the visual field of glaucoma patients with controlled IOP. Further studies are needed to determine the safety and effectiveness of long-term EBHM treatment.
Fluoxetine versus Vitex agnus castus extract in the treatment of premenstrual dysphoric disorder.
Atmaca, Murad; Kumru, Selahattin; Tezcan, Ertan
2003-04-01
Clinical trials have demonstrated that serotonin reuptake inhibitors (SRIs) and the extract of Vitex agnus castus are effective for the treatment of premenstrual dysphoric disorder (PMDD). However, to the best of our knowledge, there has been no study comparing the efficacy of the SRIs with Vitex agnus castus (AC) extract. Therefore, the aim of the present study was to compare the efficacy of fluoxetine, a selective serotonin reuptake inhibitor (SSRI), with that of the AC extract, a natural choice. After a period of 2 screening months to screen the patients for suitability, 41 patients with PMDD according to DSM-IV were recruited into the study. The patients were randomized to fluoxetine or AC for 2 months of single-blind, rater- blinded and prospective treatment period. The outcome measures included the Penn daily symptom report (DSR), the Hamilton depression rating scale (HAM-D), and the clinical global impression-severity of illness (CGI-SI) and -improvement (CGI-I) scales. At endpoint, using the clinical criterion for improvement, a similar percentage of patients responded to fluoxetine (68.4%, n = 13) and AC (57.9%, n = 11). There was no statistically significant difference between the groups with respect to the rate of responders. This preliminary study suggests that patients with PMDD respond well to treatment with both fluoxetine and AC. However, fluoxetine was more effective for psychological symptoms while the extract diminished the physical symptoms. Copyright 2002 John Wiley & Sons, Ltd.
The effect of cannabis on tremor in patients with multiple sclerosis.
Fox, P; Bain, P G; Glickman, S; Carroll, C; Zajicek, J
2004-04-13
Disabling tremor is common in patients with multiple sclerosis (MS). Data from animal model experiments and subjective and small objective studies involving patients suggest that cannabis may be an effective treatment for tremor associated with MS. To our knowledge, there are no published double-blind randomized controlled trials of cannabis as a treatment for tremor in MS patients. The authors conducted a randomized double-blind placebo-controlled crossover trial to examine the effect of oral cannador (cannabis extract) on 14 patients with MS with upper limb tremors. There were eight women and six men, with a mean age of 45 years and mean Expanded Disability Status Scale score of 6.25. Patients were randomly assigned to receive each treatment and the doses escalated over a 2-week period before each assessment. The primary outcome was change on a tremor index, measured using a validated tremor rating scale. The study was powered to detect a functionally significant 50% improvement in the tremor index. Secondary outcomes included accelerometry, an ataxia scale, spiral drawing, finger tapping, and nine-hole pegboard test performance. Analysis of the data showed no significant improvement in any of the objective measures of upper limb tremor with cannabis extract compared to placebo. Finger tapping was faster on placebo compared to cannabis extract (p < 0.02). However, there was a nonsignificant trend for patients to experience more subjective relief from their tremors while on cannabis extract compared to placebo. Cannabis extract does not produce a functionally significant improvement in MS-associated tremor.
Al-Shayyab, Mohammad H
2017-01-01
The aim of this study was to evaluate the efficacy of, and patients' subjective responses to, periodontal ligament (PDL) anesthetic injection compared to traditional local-anesthetic infiltration injection for the nonsurgical extraction of one posterior maxillary permanent tooth. All patients scheduled for nonsurgical symmetrical maxillary posterior permanent tooth extraction in the Department of Oral and Maxillofacial Surgery at the University of Jordan Hospital, Amman, Jordan over a 7-month period were invited to participate in this prospective randomized double-blinded split-mouth study. Every patient received the recommended volume of 2% lidocaine with 1:100,000 epinephrine for PDL injection on the experimental side and for local infiltration on the control side. A visual analog scale (VAS) and verbal rating scale (VRS) were used to describe pain felt during injection and extraction, respectively. Statistical significance was based on probability values <0.05 and measured using χ 2 and Student t -tests and nonparametric Mann-Whitney and Kruskal-Wallis tests. Of the 73 patients eligible for this study, 55 met the inclusion criteria: 32 males and 23 females, with a mean age of 34.87±14.93 years. Differences in VAS scores and VRS data between the two techniques were statistically significant ( P <0.001) and in favor of the infiltration injection. The PDL injection may not be the alternative anesthetic technique of choice to routine local infiltration for the nonsurgical extraction of one posterior maxillary permanent tooth.
Underdetermined blind separation of three-way fluorescence spectra of PAHs in water.
Yang, Ruifang; Zhao, Nanjing; Xiao, Xue; Zhu, Wei; Chen, Yunan; Yin, Gaofang; Liu, Jianguo; Liu, Wenqing
2018-06-15
In this work, underdetermined blind decomposition method is developed to recognize individual components from the three-way fluorescent spectra of their mixtures by using sparse component analysis (SCA). The mixing matrix is estimated from the mixtures using fuzzy data clustering algorithm together with the scatters corresponding to local energy maximum value in the time-frequency domain, and the spectra of object components are recovered by pseudo inverse technique. As an example, using this method three and four pure components spectra can be blindly extracted from two samples of their mixture, with similarities between resolved and reference spectra all above 0.80. This work opens a new and effective path to realize monitoring PAHs in water by three-way fluorescence spectroscopy technique. Copyright © 2018 Elsevier B.V. All rights reserved.
The Postural Responses to a Moving Environment of Adults Who Are Blind
ERIC Educational Resources Information Center
Stoffregen, Thomas A.; Ito, Kiyohide; Hove, Philip; Yank, Jane Redfield; Bardy, Benoit G.
2010-01-01
Adults who are blind stood in a room that could be moved around them. A sound source moved with the room, simulating the acoustic consequences of body sway. Body sway was greater when the room moved than when it was stationary, suggesting that sound may have been used to control stance. (Contains 1 figure.)
A Regularization Approach to Blind Deblurring and Denoising of QR Barcodes.
van Gennip, Yves; Athavale, Prashant; Gilles, Jérôme; Choksi, Rustum
2015-09-01
QR bar codes are prototypical images for which part of the image is a priori known (required patterns). Open source bar code readers, such as ZBar, are readily available. We exploit both these facts to provide and assess purely regularization-based methods for blind deblurring of QR bar codes in the presence of noise.
ERIC Educational Resources Information Center
International Federation of Library Associations, The Hague (Netherlands).
Papers on library services and developments in reading materials for the blind and disabled presented at the 1984 IFLA general conference include: (1) "The Establishment of a Library Service to Visually Handicapped People in African Developing Countries" (Paulli Thomsen, Denmark); (2) "Sources of Assistance for Establishing Braille…
Code of Federal Regulations, 2014 CFR
2014-10-01
... matter may be necessary to submit a proposal or perform the contract does not, in itself, justify use of... section 8(a) of the Small Business Act (but see 5.205(f)), or from a specific source such as a workshop for the blind under the rules of the Committee for Purchase from People Who Are Blind or Severely...
ERIC Educational Resources Information Center
Cylke, Frank Kurt, Ed.
The booklet provides resources for blind and visually handicapped individuals interested in birding as a hobby. It describes a midwestern group of visually impaired birders and discusses the importance and variety of bird sounds. Listed are a selection of recorded and braille books available on birding, sources of commercial recordings of bird…
Blind source separation and localization using microphone arrays
NASA Astrophysics Data System (ADS)
Sun, Longji
The blind source separation and localization problem for audio signals is studied using microphone arrays. Pure delay mixtures of source signals typically encountered in outdoor environments are considered. Our proposed approach utilizes the subspace methods, including multiple signal classification (MUSIC) and estimation of signal parameters via rotational invariance techniques (ESPRIT) algorithms, to estimate the directions of arrival (DOAs) of the sources from the collected mixtures. Since audio signals are generally considered broadband, the DOA estimates at frequencies with the large sum of squared amplitude values are combined to obtain the final DOA estimates. Using the estimated DOAs, the corresponding mixing and demixing matrices are computed, and the source signals are recovered using the inverse short time Fourier transform. Subspace methods take advantage of the spatial covariance matrix of the collected mixtures to achieve robustness to noise. While the subspace methods have been studied for localizing radio frequency signals, audio signals have their special properties. For instance, they are nonstationary, naturally broadband and analog. All of these make the separation and localization for the audio signals more challenging. Moreover, our algorithm is essentially equivalent to the beamforming technique, which suppresses the signals in unwanted directions and only recovers the signals in the estimated DOAs. Several crucial issues related to our algorithm and their solutions have been discussed, including source number estimation, spatial aliasing, artifact filtering, different ways of mixture generation, and source coordinate estimation using multiple arrays. Additionally, comprehensive simulations and experiments have been conducted to examine various aspects of the algorithm. Unlike the existing blind source separation and localization methods, which are generally time consuming, our algorithm needs signal mixtures of only a short duration and therefore supports real-time implementation.
de la Barrera-Núñez, M-C; Yáñez-Vico, R-M; Batista-Cruzado, A; Heurtebise-Saavedra, J-M; Castillo-de Oyagüe, R; Torres-Lagares, D
2014-03-01
To evaluate the anti-inflammatory and analgesic effect of Bromelain (pineapple extract) administered orally in the postoperative after extraction of impacted lower molars. This is a prospective, placebo-controlled, unicentric, double-blind study; the sample size was 34 patients. The pre and postoperative outcomes, evaluated on the third (D3) and eighth day (D8), included inflamtion, pain and oral aperture, as well as the need for analgesics. One group received Bromelain 150mg per day for three days and 100mg on days 4 to 7. The other group received placebo in the same dosage. All outcomes werrecorded quantitatively and analyzed with the Mann-Whitney U test for independent samples. Although there were no statistically significant differences between the treatment groups, a trend towards less inflammation and improved oral aperture was observed in the group that received Bromelain, compared to the group that received placebo. This trend can be attributed completely to random reasons, since there is no statistical difference in the results. Further studies are necessary to analyze different administration patterns and doses of Bromelain for the use in the postoperative of impacted third molars.
2010-01-01
Background Hibiscus sabdariffa is used regularly in folk medicine to treat various conditions. Methods The study was a double blind, placebo controlled, randomized trial. Sixty subjects with serum LDL values in the range of 130-190 mg/dl and with no history of coronary heart disease were randomized into experimental and placebo groups. The experimental group received 1 gm of the extract for 90 days while the placebo received a similar amount of maltodextrin in addition to dietary and physical activity advice for the control of their blood lipids. Anthropometry, blood biochemistry, dietary and physical activity were assessed at baseline, day 45 and day 90. Results While body weight, serum LDL cholesterol and triglyceride levels decreased in both groups, there were no significant differences between the experimental and placebo group. Conclusions It is likely that the observed effects were as a result of the patients following the standard dietary and physical activity advice. At a dose of 1 gm/day, hibiscus sabdariffa leaf extract did not appear to have a blood lipid lowering effect. Trial Registration REFCTRI2009000472 PMID:20553629
Kim, Judy S; Kanjlia, Shipra; Merabet, Lotfi B; Bedny, Marina
2017-11-22
Learning to read causes the development of a letter- and word-selective region known as the visual word form area (VWFA) within the human ventral visual object stream. Why does a reading-selective region develop at this anatomical location? According to one hypothesis, the VWFA develops at the nexus of visual inputs from retinotopic cortices and linguistic input from the frontotemporal language network because reading involves extracting linguistic information from visual symbols. Surprisingly, the anatomical location of the VWFA is also active when blind individuals read Braille by touch, suggesting that vision is not required for the development of the VWFA. In this study, we tested the alternative prediction that VWFA development is in fact influenced by visual experience. We predicted that in the absence of vision, the "VWFA" is incorporated into the frontotemporal language network and participates in high-level language processing. Congenitally blind ( n = 10, 9 female, 1 male) and sighted control ( n = 15, 9 female, 6 male), male and female participants each took part in two functional magnetic resonance imaging experiments: (1) word reading (Braille for blind and print for sighted participants), and (2) listening to spoken sentences of different grammatical complexity (both groups). We find that in blind, but not sighted participants, the anatomical location of the VWFA responds both to written words and to the grammatical complexity of spoken sentences. This suggests that in blindness, this region takes on high-level linguistic functions, becoming less selective for reading. More generally, the current findings suggest that experience during development has a major effect on functional specialization in the human cortex. SIGNIFICANCE STATEMENT The visual word form area (VWFA) is a region in the human cortex that becomes specialized for the recognition of written letters and words. Why does this particular brain region become specialized for reading? We tested the hypothesis that the VWFA develops within the ventral visual stream because reading involves extracting linguistic information from visual symbols. Consistent with this hypothesis, we find that in congenitally blind Braille readers, but not sighted readers of print, the VWFA region is active during grammatical processing of spoken sentences. These results suggest that visual experience contributes to VWFA specialization, and that different neural implementations of reading are possible. Copyright © 2017 the authors 0270-6474/17/3711495-10$15.00/0.
Kanjlia, Shipra; Merabet, Lotfi B.
2017-01-01
Learning to read causes the development of a letter- and word-selective region known as the visual word form area (VWFA) within the human ventral visual object stream. Why does a reading-selective region develop at this anatomical location? According to one hypothesis, the VWFA develops at the nexus of visual inputs from retinotopic cortices and linguistic input from the frontotemporal language network because reading involves extracting linguistic information from visual symbols. Surprisingly, the anatomical location of the VWFA is also active when blind individuals read Braille by touch, suggesting that vision is not required for the development of the VWFA. In this study, we tested the alternative prediction that VWFA development is in fact influenced by visual experience. We predicted that in the absence of vision, the “VWFA” is incorporated into the frontotemporal language network and participates in high-level language processing. Congenitally blind (n = 10, 9 female, 1 male) and sighted control (n = 15, 9 female, 6 male), male and female participants each took part in two functional magnetic resonance imaging experiments: (1) word reading (Braille for blind and print for sighted participants), and (2) listening to spoken sentences of different grammatical complexity (both groups). We find that in blind, but not sighted participants, the anatomical location of the VWFA responds both to written words and to the grammatical complexity of spoken sentences. This suggests that in blindness, this region takes on high-level linguistic functions, becoming less selective for reading. More generally, the current findings suggest that experience during development has a major effect on functional specialization in the human cortex. SIGNIFICANCE STATEMENT The visual word form area (VWFA) is a region in the human cortex that becomes specialized for the recognition of written letters and words. Why does this particular brain region become specialized for reading? We tested the hypothesis that the VWFA develops within the ventral visual stream because reading involves extracting linguistic information from visual symbols. Consistent with this hypothesis, we find that in congenitally blind Braille readers, but not sighted readers of print, the VWFA region is active during grammatical processing of spoken sentences. These results suggest that visual experience contributes to VWFA specialization, and that different neural implementations of reading are possible. PMID:29061700
Determination of the optimal number of components in independent components analysis.
Kassouf, Amine; Jouan-Rimbaud Bouveresse, Delphine; Rutledge, Douglas N
2018-03-01
Independent components analysis (ICA) may be considered as one of the most established blind source separation techniques for the treatment of complex data sets in analytical chemistry. Like other similar methods, the determination of the optimal number of latent variables, in this case, independent components (ICs), is a crucial step before any modeling. Therefore, validation methods are required in order to decide about the optimal number of ICs to be used in the computation of the final model. In this paper, three new validation methods are formally presented. The first one, called Random_ICA, is a generalization of the ICA_by_blocks method. Its specificity resides in the random way of splitting the initial data matrix into two blocks, and then repeating this procedure several times, giving a broader perspective for the selection of the optimal number of ICs. The second method, called KMO_ICA_Residuals is based on the computation of the Kaiser-Meyer-Olkin (KMO) index of the transposed residual matrices obtained after progressive extraction of ICs. The third method, called ICA_corr_y, helps to select the optimal number of ICs by computing the correlations between calculated proportions and known physico-chemical information about samples, generally concentrations, or between a source signal known to be present in the mixture and the signals extracted by ICA. These three methods were tested using varied simulated and experimental data sets and compared, when necessary, to ICA_by_blocks. Results were relevant and in line with expected ones, proving the reliability of the three proposed methods. Copyright © 2017 Elsevier B.V. All rights reserved.
48 CFR 52.208-9 - Contractor Use of Mandatory Sources of Supply or Services.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by the Committee for Purchase From People Who Are Blind or Severely Disabled (the Committee) under... mandatory source is unsatisfactory. The Contractor shall not purchase the supplies or services from other... central nonprofit agency has authorized purchase from other sources. (c) Price and delivery information...
OLED lighting devices having multi element light extraction and luminescence conversion layer
Krummacher, Benjamin Claus; Antoniadis, Homer
2010-11-16
An apparatus such as a light source has a multi element light extraction and luminescence conversion layer disposed over a transparent layer of the light source and on the exterior of said light source. The multi-element light extraction and luminescence conversion layer includes a plurality of light extraction elements and a plurality of luminescence conversion elements. The light extraction elements diffuses the light from the light source while luminescence conversion elements absorbs a first spectrum of light from said light source and emits a second spectrum of light.
Online estimation of room reverberation time
NASA Astrophysics Data System (ADS)
Ratnam, Rama; Jones, Douglas L.; Wheeler, Bruce C.; Feng, Albert S.
2003-04-01
The reverberation time (RT) is an important parameter for characterizing the quality of an auditory space. Sounds in reverberant environments are subject to coloration. This affects speech intelligibility and sound localization. State-of-the-art signal processing algorithms for hearing aids are expected to have the ability to evaluate the characteristics of the listening environment and turn on an appropriate processing strategy accordingly. Thus, a method for the characterization of room RT based on passively received microphone signals represents an important enabling technology. Current RT estimators, such as Schroeder's method or regression, depend on a controlled sound source, and thus cannot produce an online, blind RT estimate. Here, we describe a method for estimating RT without prior knowledge of sound sources or room geometry. The diffusive tail of reverberation was modeled as an exponentially damped Gaussian white noise process. The time constant of the decay, which provided a measure of the RT, was estimated using a maximum-likelihood procedure. The estimates were obtained continuously, and an order-statistics filter was used to extract the most likely RT from the accumulated estimates. The procedure was illustrated for connected speech. Results obtained for simulated and real room data are in good agreement with the real RT values.
Nelson, Erika D.; Ramberg, Jane E.; Best, Talitha; Sinnott, Robert A.
2012-01-01
Objectives Current research efforts are centered on delineating the novel health benefits of naturally derived saccharides, including growing interest in their abilities to influence neurologic health. We performed a comprehensive review of the literature to consolidate all controlled studies assessing various roles of exogenous saccharide compounds and polysaccharide-rich extracts from plants, fungi, and other natural sources on brain function, with a significant focus on benefits derived from oral intake. Methods Studies were identified by conducting electronic searches on PubMed and Google Scholar. Reference lists of articles were also reviewed for additional relevant studies. Only articles published in English were included in this review. Results Six randomized, double-blind, placebo-controlled clinical studies were identified in which consumption of a blend of plant-derived polysaccharides showed positive effects on cognitive function and mood in healthy adults. A separate controlled clinical study observed improvements in well-being with ingestion of a yeast beta-glucan. Numerous animal and in vitro studies have demonstrated the ability of individual saccharide compounds and polysaccharide-rich extracts to modify behavior, enhance synaptic plasticity, and provide neuroprotective effects. Discussion Although the mechanisms by which exogenous saccharides can influence brain function are not well understood at this time, the literature suggests that certain naturally occurring compounds and polysaccharide-rich extracts show promise, when taken orally, in supporting neurologic health and function. Additional well-controlled clinical studies on larger populations are necessary, however, before specific recommendations can be made. PMID:22417773
Crawford, Paul; Thai, Chuong; Obholz, Joshua; Schievenin, Jeffrey; True, Mark; Shah, Sachin A; Hallgren, John; Clark, Jill; Sharon, Danny
2016-01-05
The World Health Organization predicts that by 2030 diabetes will be the seventh leading cause of death in the world. Multiple studies have tried to determine if cinnamon is an effective treatment for diabetes. Cinnamon extract is an insulin sensitizer, protects mesangial cells, decreases inflammatory markers, and lowers glucose, lipids, and blood pressure in patients with type 2 diabetes, so we developed a protocol to study whether ingestion of water-soluble cinnamon extract prevents progression from pre-diabetes to diabetes. This is a randomized, double-blind, placebo-controlled trial comparing cinnamon extract versus placebo in subjects with pre-diabetes who have committed to participate in a lifestyle change program. The trial will be conducted at five sites and will include 428 subjects who take cinnamon extract or placebo for 1 year. Follow-up for these subjects will be for a total of 2 years (nine study visits). The primary outcomes to be assessed are 1) conversion of patients from pre-diabetes to diabetes and 2) impact of water-soluble cinnamon extract on hepatic transaminases, renal function, and QT interval on electrocardiogram. Secondary outcomes include changes in HbA1c, lipids, waist circumference, weight, blood pressure, and fasting plasma glucose. The trial protocol has been approved by the Institutional Review Board of the US Air Force 59th Medical Wing, Wilford Hall Ambulatory Surgical Center (Protocol FWH20110035H). Investigator-sponsored Investigational New Drug status (114078) was granted by the US Food and Drug Administration. This study will provide high-quality evidence of the efficacy of water-soluble cinnamon extract in conjunction with lifestyle intervention for preventing patients with pre-diabetes from converting to diabetes. Additionally, it will provide important safety information about water-soluble cinnamon extract. ClinicalTrials.gov Identifier: NCT01301521 , 18 February 2011.
Jahanbakhsh, Seyedeh Pardis; Manteghi, Ali Akhondpour; Emami, Seyed Ahmad; Mahyari, Saman; Gholampour, Beheshteh; Mohammadpour, Amir Hooshang; Sahebkar, Amirhossein
2016-08-01
Obsessive-compulsive disorder (OCD) is a chronic psychiatric disorder that is causally linked to dysregulation of the serotonergic system. The aim of this study is to investigate the efficacy of Withania somnifera (W. somnifera) root extract as an adjunct therapy to standard OCD treatment. Thirty patients with a confirmed diagnosis of OCD according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) criteria participated in this randomized double-blind placebo-controlled trial and were randomly assigned to the treatment group (W. somnifera extract, 120mg/day; n=15) or the placebo group (n=15). All patients were under treatment with Selective Serotonin Re-uptake Inhibitors (SSRIs), and were instructed to take 4 capsules of the extract or placebo per day, preferably after meals, for a period of six weeks. The Yale-Brown Obsessive-Compulsive Scale (Y-BOCS) was used in order to assess the severity of OCD symptoms at baseline and at the end of the trial. Statistical analyses were performed using SPSS software and Y-BOCS values were presented as median and range (Min-Max). Comparison of the change in Y-BOCS score during the course of the trial revealed a significantly greater effect of W. somnifera (26 (14-40) [pre-treatment] versus 14 (4-40) [post-treatment]; change: -8 (-23 to 0)) versus placebo (18 (11-33) [pre-treatment] versus 16 (10-31) [post-treatment]; change: -2 (-4 to 0)) (P<0.001). The extract was safe and no adverse event was reported during the trial. W. somnifera extract may be beneficial as a safe and effective adjunct to SSRIs in the treatment of OCD. Copyright © 2016. Published by Elsevier Ltd.
Armijo-Olivo, Susan; Cummings, Greta G.; Amin, Maryam; Flores-Mir, Carlos
2017-01-01
Objectives To examine the risks of bias, risks of random errors, reporting quality, and methodological quality of randomized clinical trials of oral health interventions and the development of these aspects over time. Methods We included 540 randomized clinical trials from 64 selected systematic reviews. We extracted, in duplicate, details from each of the selected randomized clinical trials with respect to publication and trial characteristics, reporting and methodologic characteristics, and Cochrane risk of bias domains. We analyzed data using logistic regression and Chi-square statistics. Results Sequence generation was assessed to be inadequate (at unclear or high risk of bias) in 68% (n = 367) of the trials, while allocation concealment was inadequate in the majority of trials (n = 464; 85.9%). Blinding of participants and blinding of the outcome assessment were judged to be inadequate in 28.5% (n = 154) and 40.5% (n = 219) of the trials, respectively. A sample size calculation before the initiation of the study was not performed/reported in 79.1% (n = 427) of the trials, while the sample size was assessed as adequate in only 17.6% (n = 95) of the trials. Two thirds of the trials were not described as double blinded (n = 358; 66.3%), while the method of blinding was appropriate in 53% (n = 286) of the trials. We identified a significant decrease over time (1955–2013) in the proportion of trials assessed as having inadequately addressed methodological quality items (P < 0.05) in 30 out of the 40 quality criteria, or as being inadequate (at high or unclear risk of bias) in five domains of the Cochrane risk of bias tool: sequence generation, allocation concealment, incomplete outcome data, other sources of bias, and overall risk of bias. Conclusions The risks of bias, risks of random errors, reporting quality, and methodological quality of randomized clinical trials of oral health interventions have improved over time; however, further efforts that contribute to the development of more stringent methodology and detailed reporting of trials are still needed. PMID:29272315
Saltaji, Humam; Armijo-Olivo, Susan; Cummings, Greta G; Amin, Maryam; Flores-Mir, Carlos
2017-01-01
To examine the risks of bias, risks of random errors, reporting quality, and methodological quality of randomized clinical trials of oral health interventions and the development of these aspects over time. We included 540 randomized clinical trials from 64 selected systematic reviews. We extracted, in duplicate, details from each of the selected randomized clinical trials with respect to publication and trial characteristics, reporting and methodologic characteristics, and Cochrane risk of bias domains. We analyzed data using logistic regression and Chi-square statistics. Sequence generation was assessed to be inadequate (at unclear or high risk of bias) in 68% (n = 367) of the trials, while allocation concealment was inadequate in the majority of trials (n = 464; 85.9%). Blinding of participants and blinding of the outcome assessment were judged to be inadequate in 28.5% (n = 154) and 40.5% (n = 219) of the trials, respectively. A sample size calculation before the initiation of the study was not performed/reported in 79.1% (n = 427) of the trials, while the sample size was assessed as adequate in only 17.6% (n = 95) of the trials. Two thirds of the trials were not described as double blinded (n = 358; 66.3%), while the method of blinding was appropriate in 53% (n = 286) of the trials. We identified a significant decrease over time (1955-2013) in the proportion of trials assessed as having inadequately addressed methodological quality items (P < 0.05) in 30 out of the 40 quality criteria, or as being inadequate (at high or unclear risk of bias) in five domains of the Cochrane risk of bias tool: sequence generation, allocation concealment, incomplete outcome data, other sources of bias, and overall risk of bias. The risks of bias, risks of random errors, reporting quality, and methodological quality of randomized clinical trials of oral health interventions have improved over time; however, further efforts that contribute to the development of more stringent methodology and detailed reporting of trials are still needed.
Mao, Jun J; Li, Qing S; Soeller, Irene; Rockwell, Kenneth; Xie, Sharon X; Amsterdam, Jay D
2014-11-01
Anxiety symptoms are among the most common reasons for consumers to use Complementary and Alternative Medicine (CAM) therapy. Although many botanicals have been proposed as putative remedies for anxiety symptoms, there has been a paucity of controlled trials of these remedies. A preliminary study of the anxiolytic effect of Chamomile ( Matricaria recutita ) in humans suggests that chamomile may have anxiolytic and antidepressant activity. We now seek to conduct a 5-year randomized, double-blind, placebo-substitution study to examine the short and long-term safety and efficacy of chamomile extract in Generalized Anxiety Disorder (GAD). 180 subjects with moderate to severe GAD will receive initial open-label pharmaceutical-grade chamomile extract 500-1,500 mg daily for 8 weeks. Responders to treatment who remain well for an additional 4 weeks of consolidation therapy, will be randomized to double-blind continuation therapy with either chamomile extract 500-1,500 mg daily or placebo for an additional 26 weeks. The primary outcome will be the time to relapse during study continuation therapy in each treatment condition. Secondary outcomes will include the proportion of subjects in each treatment condition who relapse, as well as the proportion of subjects with treatment-emergent adverse events. Quality of life ratings will also be compared between treatment conditions during short and long-term therapy. Many individuals with mental disorders decline conventional therapy and seek CAM therapies for their symptoms. Thus, the identification of effective CAM therapy is of relevance to reducing the burden of mental illness. This study builds upon our prior findings of significant superiority of chamomile versus placebo in reducing GAD symptoms. We now extend these preliminary findings by conducting a randomized long-term safety and efficacy study of chamomile in GAD.
Library Aids and Services Available to the Blind and Visually Handicapped. First Edition.
ERIC Educational Resources Information Center
Delta Gamma Foundation, Columbus, OH.
The information contained in this publication will be helpful in carrying out projects to aid blind and visually handicapped children and adults of all ages. Special materials available from the Library of Congress such as: talking books, books in braille, large print books, and books in moon type are described. Other sources of reading materials…
Project Word-Back: Exploratory Follow-Up Study on Deaf-Blind (Rubella) Children in California.
ERIC Educational Resources Information Center
Scheffelin, Edward J.
Project Word-Back, an exploratory followup study of 21 young deaf-blind (Rubella) children (6 to 9 years old), was conducted to establish a tentative reference source of information, obtain teacher estimates on selected aspects of the current functioning level of a sample of children, and provide basic data from which hypotheses may be formulated…
A blind source separation approach for humpback whale song separation.
Zhang, Zhenbin; White, Paul R
2017-04-01
Many marine mammal species are highly social and are frequently encountered in groups or aggregations. When conducting passive acoustic monitoring in such circumstances, recordings commonly contain vocalizations of multiple individuals which overlap in time and frequency. This paper considers the use of blind source separation as a method for processing these recordings to separate the calls of individuals. The example problem considered here is that of the songs of humpback whales. The high levels of noise and long impulse responses can make source separation in underwater contexts a challenging proposition. The approach present here is based on time-frequency masking, allied to a noise reduction process. The technique is assessed using simulated and measured data sets, and the results demonstrate the effectiveness of the method for separating humpback whale songs.
Narayan, Sanjiv M.; Baykaner, Tina; Clopton, Paul; Schricker, Amir; Lalani, Gautam; Krummen, David E.; Shivkumar, Kalyanam; Miller, John M.
2014-01-01
Objectives To determine if ablation that targets patient-specific AF-sustaining substrates (rotors or focal sources) is more durable than trigger ablation alone at preventing late AF recurrences. Background Late recurrence substantially limits the efficacy of pulmonary vein (PV) isolation for AF, and is associated with PV reconnection and the emergence of new triggers. Methods We performed 3 year follow-up of the CONFIRM trial, in which 92 consecutive AF patients (70.7% persistent) underwent novel computational mapping to reveal a median of 2 (IQR 1–2) rotors or focal sources in 97.7% of patients during AF. Ablation comprised source (Focal Impulse and Rotor Modulation, FIRM) then conventional ablation in n=27 (FIRM-guided), and conventional ablation alone in n=65 (FIRM-blinded). Patients were followed with implanted ECG monitors when possible (85.2% FIRM guided, 23.1% FIRM-blinded). Results On 890 days follow-up (median; IQR 224–1563) compared FIRM-blinded therapy, patients receiving FIRM-guided ablation maintained higher freedom from AF after 1.2±0.4 procedures (median 1, IQR 1–1) (77.8% vs 38.5%; p=0.001) and a single procedure (p>0.001), and higher freedom from all atrial arrhythmias (p=0.003). Freedom from AF was higher when ablation directly or coincidentally passed through sources than when it missed sources (p>0.001). CONCLUSIONS FIRM-guided ablation is more durable than conventional trigger-based ablation at preventing 3 year AF recurrence. Future studies should investigate how ablation of patient-specific AF-sustaining rotors and focal sources alters the natural history of arrhythmia recurrence. PMID:24632280
Ultra-short ion and neutron pulse production
Leung, Ka-Ngo; Barletta, William A.; Kwan, Joe W.
2006-01-10
An ion source has an extraction system configured to produce ultra-short ion pulses, i.e. pulses with pulse width of about 1 .mu.s or less, and a neutron source based on the ion source produces correspondingly ultra-short neutron pulses. To form a neutron source, a neutron generating target is positioned to receive an accelerated extracted ion beam from the ion source. To produce the ultra-short ion or neutron pulses, the apertures in the extraction system of the ion source are suitably sized to prevent ion leakage, the electrodes are suitably spaced, and the extraction voltage is controlled. The ion beam current leaving the source is regulated by applying ultra-short voltage pulses of a suitable voltage on the extraction electrode.
Bravo-Pérez, Manuel; Sánchez-López, José D.; Muñoz-Soto, Esther; Romero-Olid, María N.; Baca-García, Pilar
2013-01-01
Purpose: Alveolar osteitis (AO) is the most common postoperative complication of dental extractions. The purpose of this study was to compare the effectiveness of 1% versus 0.2% chlorhexidine (CHX) gel in reducing postoperative AO after surgical extraction of mandibular third molars, and assess the impact of treatment on the Oral HealthRelated Quality of Life (OHRQoL). Material and Methods: This clinical study was a randomized, double-blind clinical trial. Eighty eight patients underwent surgical extraction of one retained mandibular third molar with the intra-alveolar application of 0.2% CHX gel. Afterwards, they were assigned to one of two groups: 1% CHX gel (n=42) or 0.2% CHX gel (n=46). The patients applied the gel twice a day to the wound for one week. All patients were evaluated for AO. Results: In the 0.2% CHX gel group, 13% of AO incidence was found, while in the 1% CHX gel group, AO incidence was 7%, a difference that was not statistically significant. Variables such as sensation of pain and inflammation at baseline and during one week, as well as OHRQoL of the patients at 24 hours and 7 days post-extraction, gave no statistically significant differences. Conclusions: There are no significant differences in AO after surgical extraction of mandibular third molars, when comparing applying 1% CHX gel twice a day for 7 days with 0.2% CHX gel. Key words:Alveolar osteitis, chlorhexidine gel, third molar. PMID:23722126
Al-Shayyab, Mohammad H
2017-01-01
Aim The aim of this study was to evaluate the efficacy of, and patients’ subjective responses to, periodontal ligament (PDL) anesthetic injection compared to traditional local-anesthetic infiltration injection for the nonsurgical extraction of one posterior maxillary permanent tooth. Materials and methods All patients scheduled for nonsurgical symmetrical maxillary posterior permanent tooth extraction in the Department of Oral and Maxillofacial Surgery at the University of Jordan Hospital, Amman, Jordan over a 7-month period were invited to participate in this prospective randomized double-blinded split-mouth study. Every patient received the recommended volume of 2% lidocaine with 1:100,000 epinephrine for PDL injection on the experimental side and for local infiltration on the control side. A visual analog scale (VAS) and verbal rating scale (VRS) were used to describe pain felt during injection and extraction, respectively. Statistical significance was based on probability values <0.05 and measured using χ2 and Student t-tests and nonparametric Mann–Whitney and Kruskal–Wallis tests. Results Of the 73 patients eligible for this study, 55 met the inclusion criteria: 32 males and 23 females, with a mean age of 34.87±14.93 years. Differences in VAS scores and VRS data between the two techniques were statistically significant (P<0.001) and in favor of the infiltration injection. Conclusion The PDL injection may not be the alternative anesthetic technique of choice to routine local infiltration for the nonsurgical extraction of one posterior maxillary permanent tooth. PMID:29070950
Antoniadis,; Homer, Krummacher [Mountain View, CA; Claus, Benjamin [Regensburg, DE
2008-01-22
An apparatus such as a light source has a multi-element light extraction and luminescence conversion layer disposed over a transparent layer of the light source and on the exterior of said light source. The multi-element light extraction and luminescence conversion layer includes a plurality of light extraction elements and a plurality of luminescence conversion elements. The light extraction elements diffuses the light from the light source while luminescence conversion elements absorbs a first spectrum of light from said light source and emits a second spectrum of light.
The modification at CSNS ion source
NASA Astrophysics Data System (ADS)
Liu, S.; Ouyang, H.; Huang, T.; Xiao, Y.; Cao, X.; Lv, Y.; Xue, K.; Chen, W.
2017-08-01
The commissioning of CSNS front end has been finished. Above 15 mA beam intensity is obtained at the end of RFQ. For CSNS ion source, it is a type of penning surface plasma ion source, similar to ISIS ion source. To improve the operation stability and reduce spark rate, some modifications have been performed, including Penning field, extraction optics and post acceleration. PBGUNS is applied to optimize beam extraction. The co-extraction electrons are considered at PBGUNS simulation and various extracted structure are simulated aiming to make the beam through the extracted electrode without loss. The stability of ion source is improved further.
[Which treatments for infantile colics?].
Bruyas-Bertholon, Virginie; Lachaux, Alain; Dubois, Jean-Pierre; Fourneret, Pierre; Letrilliart, Laurent
2012-07-01
Infantile colics or excessive crying represent a source of stress for parents and a frequent reason for encounter in primary care. To assess the effectiveness of treatments of this syndrome from a systematic review. Medline, Cochrane and Embase databases. We used the following inclusion criteria: therapeutic assessment of infant colics or excessive crying, randomized controlled trials or meta-analyses, published in English or French language. Thirty-one randomized controlled trials and one meta-analysis have been included. Allopathic drugs have not proved effectiveness (simethicone, lactase) and some of them can cause potentially serious adverse reactions (dicyclomine). Protein hydrolysate or soy formulas seem to be effective, but soy milk can induce allergies. Sucrose solutions provide some benefit in studies with low level of evidence. Effectiveness is likely for a probiotics (Lactobacillus reuteri) and for herbal mixtures containing fennel extracts. Evidence is lacking for manual (osteopathy, acupuncture) and behavioural therapies (decreased stimulations, reassurance of parents). The definition of infantile colics and the methods used for crying measurement changed across trials. The included trials were of variable quality, especially with no double-blind procedure in 17 trials. The most validated treatments for infantile colics are the substitution of cows' milk by a hydrolysed formula, the use of L. reuteri and of fennel extracts. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
A Comparative Survey of Methods for Remote Heart Rate Detection From Frontal Face Videos
Wang, Chen; Pun, Thierry; Chanel, Guillaume
2018-01-01
Remotely measuring physiological activity can provide substantial benefits for both the medical and the affective computing applications. Recent research has proposed different methodologies for the unobtrusive detection of heart rate (HR) using human face recordings. These methods are based on subtle color changes or motions of the face due to cardiovascular activities, which are invisible to human eyes but can be captured by digital cameras. Several approaches have been proposed such as signal processing and machine learning. However, these methods are compared with different datasets, and there is consequently no consensus on method performance. In this article, we describe and evaluate several methods defined in literature, from 2008 until present day, for the remote detection of HR using human face recordings. The general HR processing pipeline is divided into three stages: face video processing, face blood volume pulse (BVP) signal extraction, and HR computation. Approaches presented in the paper are classified and grouped according to each stage. At each stage, algorithms are analyzed and compared based on their performance using the public database MAHNOB-HCI. Results found in this article are limited on MAHNOB-HCI dataset. Results show that extracted face skin area contains more BVP information. Blind source separation and peak detection methods are more robust with head motions for estimating HR. PMID:29765940
Hariharan, Samyuktha; Narayanan, Vinod; Soh, Chen Loong
2014-12-01
We compared outcome variables (operative complications, inflammatory complications, and operating time) in patients being treated by orthodontic extraction of upper premolars with the Physics forceps or the universal extraction forceps. We organised a single blind, split-mouth clinical trial to compare the outcomes of the 2 groups (n=54 premolars). The Physics forceps group had lower mean (SD) visual analogue scores (VAS) for pain (0.59 (0.57)) on the first postoperative day than the other group (1.04 (0.85)) (p=0.03). There were no other significant differences between the 2 groups in any other variable studied. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Moore, D F; Harwood, V J; Ferguson, D M; Lukasik, J; Hannah, P; Getrich, M; Brownell, M
2005-01-01
The accuracy of ribotyping and antibiotic resistance analysis (ARA) for prediction of sources of faecal bacterial pollution in an urban southern California watershed was determined using blinded proficiency samples. Antibiotic resistance patterns and HindIII ribotypes of Escherichia coli (n = 997), and antibiotic resistance patterns of Enterococcus spp. (n = 3657) were used to construct libraries from sewage samples and from faeces of seagulls, dogs, cats, horses and humans within the watershed. The three libraries were analysed to determine the accuracy of host source prediction. The internal accuracy of the libraries (average rate of correct classification, ARCC) with six source categories was 44% for E. coli ARA, 69% for E. coli ribotyping and 48% for Enterococcus ARA. Each library's predictive ability towards isolates that were not part of the library was determined using a blinded proficiency panel of 97 E. coli and 99 Enterococcus isolates. Twenty-eight per cent (by ARA) and 27% (by ribotyping) of the E. coli proficiency isolates were assigned to the correct source category. Sixteen per cent were assigned to the same source category by both methods, and 6% were assigned to the correct category. Addition of 2480 E. coli isolates to the ARA library did not improve the ARCC or proficiency accuracy. In contrast, 45% of Enterococcus proficiency isolates were correctly identified by ARA. None of the methods performed well enough on the proficiency panel to be judged ready for application to environmental samples. Most microbial source tracking (MST) studies published have demonstrated library accuracy solely by the internal ARCC measurement. Low rates of correct classification for E. coli proficiency isolates compared with the ARCCs of the libraries indicate that testing of bacteria from samples that are not represented in the library, such as blinded proficiency samples, is necessary to accurately measure predictive ability. The library-based MST methods used in this study may not be suited for determination of the source(s) of faecal pollution in large, urban watersheds.
Yu, Chia-Chia; Nandrot, Emeline F.; Dun, Ying; Finnemann, Silvia C.
2011-01-01
In the aging human eye, oxidative damage and accumulation of pro-oxidant lysosomal lipofuscin cause functional decline of the retinal pigment epithelium (RPE), which contributes to age-related macular degeneration. In mice with an RPE-specific phagocytosis defect due to lack of αvβ5 integrin receptors, RPE accumulation of lipofuscin suggests that the age-related blindness we previously described in this model may also result from oxidative stress. Cellular and molecular targets of oxidative stress in the eye remain poorly understood. Here we identify actin among 4-hydroxynonenal (HNE) adducts formed specifically in β5−/− RPE but not neural retina with age. HNE modification directly correlated with loss of resistance of actin to detergent extraction, suggesting cytoskeletal damage in aging RPE. Dietary enrichment with natural antioxidants grapes or marigold extract containing macular pigments lutein/zeaxanthin was sufficient to prevent HNE-adduct formation, actin solubility, lipofuscin accumulation, and age-related cone and rod photoreceptor dysfunction in β5−/− mice. Acute generation of HNE-adducts directly destabilized actin but not tubulin cytoskeletal elements of RPE cells. These findings identify destabilization of the actin cytoskeleton as a consequence of physiological, sublethal oxidative burden of RPE cells in vivo that is associated with age-related blindness and that can be prevented by consuming an antioxidant-rich diet. PMID:22178979
Liu, M L; Wang, Y X
2017-05-11
Objective: To evaluate the rate of blindness caused by primary angle closure glaucoma (PACG) in Chinese population of more than 40 years old, and to explore the effectiveness of a prevention and treatment system on PACG. Methods: We searched the databases of Pubmed, ScienceDirect, Springer Link, CNKI and Wanfang Data and collected all the original studies of the prevalence and blindness of angle closure glaucoma in China. The population was limited to over 40 years old. The research site was limited to the community-based, while the published time was not limited. Two researchers completed the literature search, data extraction and methodological quality assessment independently, with same criteria. Meta analysis was performed using R software. Results: Five papers were included in this study finally. A total of 26 437 cases of natural population over the age of 40 were observed, and 306 cases of angle closure glaucoma were found, of which 113 cases had binocular or monocular blindness caused by PACG. The random effect model meta-analysis results showed that the overall blindness rate was 38.3% [95% CI (28.1%, 49.6%)]. In Beijing, where the prevention and treatment system was well established, the blindness rate was far lower than that in the areas where the system was poorly established. Compared with the past, the blindness rate caused by PACG in Beijing decreased sharply. Conclusions: The rate of blindness caused by PACG is still high in the mainland of China. The prevention and treatment system is effective and worth promoting. (Chin J Ophthalmol, 2017, 53: 373 - 377) .
Active Spread-Spectrum Steganalysis for Hidden Data Extraction
2011-09-01
steganalysis. In particular, we aim to recover blindly se- cret data hidden in image hosts via (multi-signature) direct- sequence SS embedding [18]-[25...access (CDMA) communica- tion systems. Under the assumption that the embedded se- cret messages are independent identically distributed (i.i.d.) random
Tactile spatial resolution in blind braille readers.
Van Boven, R W; Hamilton, R H; Kauffman, T; Keenan, J P; Pascual-Leone, A
2000-06-27
To determine if blind people have heightened tactile spatial acuity. Recently, studies using magnetic source imaging and somatosensory evoked potentials have shown that the cortical representation of the reading fingers of blind Braille readers is expanded compared to that of fingers of sighted subjects. Furthermore, the visual cortex is activated during certain tactile tasks in blind subjects but not sighted subjects. The authors hypothesized that the expanded cortical representation of fingers used in Braille reading may reflect an enhanced fidelity in the neural transmission of spatial details of a stimulus. If so, the quantitative limit of spatial acuity would be superior in blind people. The authors employed a grating orientation discrimination task in which threshold performance is accounted for by the spatial resolution limits of the neural image evoked by a stimulus. The authors quantified the psychophysical limits of spatial acuity at the middle and index fingers of 15 blind Braille readers and 15 sighted control subjects. The mean grating orientation threshold was significantly (p = 0.03) lower in the blind group (1.04 mm) compared to the sighted group (1.46 mm). The self-reported dominant reading finger in blind subjects had a mean grating orientation threshold of 0.80 mm, which was significantly better than other fingers tested. Thresholds at non-Braille reading fingers in blind subjects averaged 1.12 mm, which were also superior to sighted subjects' performances. Superior tactile spatial acuity in blind Braille readers may represent an adaptive, behavioral correlate of cortical plasticity.
Audible sonar images generated with proprioception for target analysis.
Kuc, Roman B
2017-05-01
Some blind humans have demonstrated the ability to detect and classify objects with echolocation using palatal clicks. An audible-sonar robot mimics human click emissions, binaural hearing, and head movements to extract interaural time and level differences from target echoes. Targets of various complexity are examined by transverse displacements of the sonar and by target pose rotations that model movements performed by the blind. Controlled sonar movements executed by the robot provide data that model proprioception information available to blind humans for examining targets from various aspects. The audible sonar uses this sonar location and orientation information to form two-dimensional target images that are similar to medical diagnostic ultrasound tomograms. Simple targets, such as single round and square posts, produce distinguishable and recognizable images. More complex targets configured with several simple objects generate diffraction effects and multiple reflections that produce image artifacts. The presentation illustrates the capabilities and limitations of target classification from audible sonar images.
An Improved Image Ringing Evaluation Method with Weighted Sum of Gray Extreme Value
NASA Astrophysics Data System (ADS)
Yang, Ling; Meng, Yanhua; Wang, Bo; Bai, Xu
2018-03-01
Blind image restoration algorithm usually produces ringing more obvious at the edges. Ringing phenomenon is mainly affected by noise, species of restoration algorithm, and the impact of the blur kernel estimation during restoration. Based on the physical mechanism of ringing, a method of evaluating the ringing on blind restoration images is proposed. The method extracts the ringing image overshooting and ripple region to make the weighted statistics for the regional gradient value. According to the weights set by multiple experiments, the edge information is used to characterize the details of the edge to determine the weight, quantify the seriousness of the ring effect, and propose the evaluation method of the ringing caused by blind restoration. The experimental results show that the method can effectively evaluate the ring effect in the restoration images under different restoration algorithms and different restoration parameters. The evaluation results are consistent with the visual evaluation results.
NASA Technical Reports Server (NTRS)
1982-01-01
A project to develop an effective mobility aid for blind pedestrians which acquires consecutive images of the scenes before a moving pedestrian, which locates and identifies the pedestrian's path and potential obstacles in the path, which presents path and obstacle information to the pedestrian, and which operates in real-time is discussed. The mobility aid has three principal components: an image acquisition system, an image interpretation system, and an information presentation system. The image acquisition system consists of a miniature, solid-state TV camera which transforms the scene before the blind pedestrian into an image which can be received by the image interpretation system. The image interpretation system is implemented on a microprocessor which has been programmed to execute real-time feature extraction and scene analysis algorithms for locating and identifying the pedestrian's path and potential obstacles. Identity and location information is presented to the pedestrian by means of tactile coding and machine-generated speech.
Detecting Signage and Doors for Blind Navigation and Wayfinding
Wang, Shuihua; Yang, Xiaodong; Tian, Yingli
2013-01-01
Signage plays a very important role to find destinations in applications of navigation and wayfinding. In this paper, we propose a novel framework to detect doors and signage to help blind people accessing unfamiliar indoor environments. In order to eliminate the interference information and improve the accuracy of signage detection, we first extract the attended areas by using a saliency map. Then the signage is detected in the attended areas by using a bipartite graph matching. The proposed method can handle multiple signage detection. Furthermore, in order to provide more information for blind users to access the area associated with the detected signage, we develop a robust method to detect doors based on a geometric door frame model which is independent to door appearances. Experimental results on our collected datasets of indoor signage and doors demonstrate the effectiveness and efficiency of our proposed method. PMID:23914345
Detecting Signage and Doors for Blind Navigation and Wayfinding.
Wang, Shuihua; Yang, Xiaodong; Tian, Yingli
2013-07-01
Signage plays a very important role to find destinations in applications of navigation and wayfinding. In this paper, we propose a novel framework to detect doors and signage to help blind people accessing unfamiliar indoor environments. In order to eliminate the interference information and improve the accuracy of signage detection, we first extract the attended areas by using a saliency map. Then the signage is detected in the attended areas by using a bipartite graph matching. The proposed method can handle multiple signage detection. Furthermore, in order to provide more information for blind users to access the area associated with the detected signage, we develop a robust method to detect doors based on a geometric door frame model which is independent to door appearances. Experimental results on our collected datasets of indoor signage and doors demonstrate the effectiveness and efficiency of our proposed method.
Dechartres, Agnes; Trinquart, Ludovic; Atal, Ignacio; Moher, David; Dickersin, Kay; Boutron, Isabelle; Perrodeau, Elodie; Altman, Douglas G; Ravaud, Philippe
2017-06-08
Objective To examine how poor reporting and inadequate methods for key methodological features in randomised controlled trials (RCTs) have changed over the past three decades. Design Mapping of trials included in Cochrane reviews. Data sources Data from RCTs included in all Cochrane reviews published between March 2011 and September 2014 reporting an evaluation of the Cochrane risk of bias items: sequence generation, allocation concealment, blinding, and incomplete outcome data. Data extraction For each RCT, we extracted consensus on risk of bias made by the review authors and identified the primary reference to extract publication year and journal. We matched journal names with Journal Citation Reports to get 2014 impact factors. Main outcomes measures We considered the proportions of trials rated by review authors at unclear and high risk of bias as surrogates for poor reporting and inadequate methods, respectively. Results We analysed 20 920 RCTs (from 2001 reviews) published in 3136 journals. The proportion of trials with unclear risk of bias was 48.7% for sequence generation and 57.5% for allocation concealment; the proportion of those with high risk of bias was 4.0% and 7.2%, respectively. For blinding and incomplete outcome data, 30.6% and 24.7% of trials were at unclear risk and 33.1% and 17.1% were at high risk, respectively. Higher journal impact factor was associated with a lower proportion of trials at unclear or high risk of bias. The proportion of trials at unclear risk of bias decreased over time, especially for sequence generation, which fell from 69.1% in 1986-1990 to 31.2% in 2011-14 and for allocation concealment (70.1% to 44.6%). After excluding trials at unclear risk of bias, use of inadequate methods also decreased over time: from 14.8% to 4.6% for sequence generation and from 32.7% to 11.6% for allocation concealment. Conclusions Poor reporting and inadequate methods have decreased over time, especially for sequence generation and allocation concealment. But more could be done, especially in lower impact factor journals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Beretta, Alberto; Accinni, Roberto; Dellanoce, Cinzia; Tonini, Annamaria; Cardot, Jean-Michel; Bussière, Anthony
2016-06-01
The antioxidant, anti-inflammatory and hepatoprotective effects of Prunus mume (PM) have previously been demonstrated. This double-blind, placebo-controlled study was designed to evaluate the influence of two doses of a food supplement, made of 150 mg of a standardized PM extract on liver transaminases, lipid profile, glycemia, neopterin and reduced and oxidized thiols in plasma and erythrocytes, during a 3-month treatment period, in healthy subjects with transaminases levels between 20 and 40 UI/L. Forty-five subjects (56.0 ± 11.6 years) were enrolled. The results showed a beneficial and statistically significant effect versus placebo of PM extract on liver function, with a decrease versus baseline in alanine aminotransferase (47%), aspartate aminotransferase (7%), gamma-glutamyl transpeptidase (15%) and glycemia (11%). The lipid profile modification was also positive with an increase versus baseline in HDL cholesterol (13%), and a decrease in LDL/HDL ratio (12%) and triglycerides (8%). The antioxidant action of PM translated into a decrease in oxidized glutathione, reduced/oxidized cysteine-glycine, oxidized cysteine (intracellular pro-oxidant) and neopterin (inflammation biomarker), was associated with an increase in reduced glutathione. These results are in favor of the use of a standardized extract of P. mume for the support of liver health and prevention of common metabolic and inflammation-based diseases. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Tanaka, Aiko; Nishimura, Mie; Sato, Yuji; Sato, Hiroki; Nishihira, Jun
2016-10-01
Pleurotus cornucopiae (Oyster mushroom, Tamogitake) has long been eaten as a functional food for enhancement of the immune system, but its effectiveness has not been well confirmed in humans. To this end, we set up a double-blind placebo-controlled human clinical trial to investigate the potential of Oyster mushrooms with respect to the up-regulation of the immune system. The subjects ingested Oyster mushroom extract for 8 weeks. We measured the serum cytokine levels involved in regulation of the immune system, including interferon (IFN)-γ, interleukin (IL)-4, IL-5, IL-10, IL-12, IL-13, and tumor-necrosis factor (TNF)-α. We found that intake of Oyster mushroom extract elevated IFN-γ ( P = 0.013) and IL-12, whereas serum levels of IL-10 and IL-13 and other cytokines were minimally changed. We also measured natural killer (NK) cell activity, the levels of which tended to increase, but not significantly. Taken together, these facts suggest that Oyster mushrooms have the potential to enhance the immune system, through Th1 phenotype potentiation as the macrophage-IL-12 - IFN-γ pathway. This results in activation of the cell-mediated immune system as exemplified by up-regulation of NK cell activity. Oyster mushroom extract may be beneficial for the prevention of various diseases, including infectious diseases and cancer, due to its stimulation of the immune system.
Rondanelli, Mariangela; Opizzi, Annalisa; Faliva, Milena; Sala, Patrizio; Perna, Simone; Riva, Antonella; Morazzoni, Paolo; Bombardelli, Ezio; Giacosa, Attilio
2014-01-01
The aim of this study is to evaluate the efficacy of a dietary supplementation with an extract from Cynara scolymus (Cs) on the glucose pattern in a group of patients with naïve impaired fasting glycaemia (IFG). A randomized, double-blind, placebo-controlled trial has been performed in 55 overweight subjects with IFG (fasting blood glucose [FBG]: 6.11 ± 0.56 mmol/l). These subjects were randomly assigned to supplement their diet with either an extract from Cs (600 mg/d) (26 subjects) or placebo (29 matched subjects) for 8 weeks. The decrease of FBG was the primary endpoint. The assessment of Homeostatic Metabolic Assessment (HOMA), glycosylated haemoglobin, A1c-Derived Average Glucose (ADAG), lipidic pattern and anthropometric parameters were the secondary endpoints. The within groups and percent changes from baseline were analyzed by the signed rank test. The comparison between groups was performed by Wilcoxon's two sample test. The supplemented group had significant decreases of: FBG (-9.6%), HOMA (-11.7%), glycosylated haemoglobin (-2.3%), ADAG (-3.1%) and lipidic pattern. The placebo group did not show any significant difference. Compared with the placebo, the supplemented group showed a significant difference in FBG, HOMA and lipidic pattern. These data demonstrate the efficacy of Cs extract on the reduction of glycometabolic parameters in overweight subjects with IFG. Copyright © 2013 John Wiley & Sons, Ltd.
Romero-Cerecero, Ofelia; Zamilpa, Alejandro; Jiménez-Ferrer, Enrique; Tortoriello, Jaime
2012-06-01
Interdigital tinea pedis is the most frequent presentation, as well as the most severe clinical form of tinea pedis, constituting a therapeutic challenge. The aim of the study was to evaluate the effectiveness and tolerability of two concentrations of Ageratina pichinchensis extract (encecalin content, 0.76 and 1.52%, respectively) on patients with clinical and mycological diagnosis of chronic interdigital tinea pedis. By means of a randomized, double-blind clinical trial, three groups of patients were treated topically for 4 weeks with a cream containing the following: Group I-the lower concentration of A. pichinchensis extract, group II-the higher concentration, group III-2% ketoconazole. One hundred and sixty (160) ambulatory patients of either sex between the ages of 18 and 65 years were enrolled. The primary outcome variables were: clinical effectiveness, mycological effectiveness, therapeutic cure, tolerability, and treatment compliance. The secondary outcome variable was therapeutic success. At the end of treatment, therapeutic cure was achieved by 34.1, 41.8, and 39.53% of Groups I, II, and III, respectively. No statistical difference between the groups was observed. Both treatments were effective for the treatment of interdigital-type tinea pedis, while better results were observed on patients that received the higher concentration of the extract.
Radzi, Che Wan Jasimah Bt wan Mohamed; Hajifaraji, Majid; Haerian, Batoul Sadat; Mosaddegh, Mohammad Hossein; Cordell, Geoffrey A.
2013-01-01
Caraway (Carum carvi L.), a potent medicinal plant, is traditionally used for treating obesity. This study investigates the weight-lowering effects of caraway extract (CE) on physically active, overweight and obese women through a randomized, triple-blind, placebo-controlled clinical trial. Seventy overweight and obese, healthy, aerobic-trained, adult females were randomly assigned to two groups (n = 35 per group). Participants received either 30 mL/day of CE or placebo without changing their diet or physical activity. Subjects were examined at baseline and after 90 days for changes in body composition, anthropometric indices, and clinical and paraclinical variables. The treatment group, compared with placebo, showed a significant reduction of weight, body mass index, body fat percentage, and waist-to-hip ratio. No changes were observed in lipid profile, urine-specific gravity, and blood pressure of subjects. The results suggest that a dietary CE with no restriction in food intake, when combined with exercise, is of value in the management of obesity in women wishing to lower their weight, BMI, body fat percentage, and body size, with no clinical side effects. In conclusion, results of this study suggest a possible phytotherapeutic approach for caraway extract in the management of obesity. This trial is registered with NCT01833377. PMID:24319489
van Odijk, J; Ahlstedt, S; Bengtsson, U; Borres, M P; Hulthén, L
2005-05-01
A firm diagnosis of double-blind placebo-controlled food challenge (DBPCFC) would facilitate the diagnosis in patients with uncertain history of reaction. Guidelines are lacking for an upper provoking dose and how to hide high concentrations of peanuts. To develop and evaluate a double-blind recipe with minimum 10% of peanut. To compare the recipe with published recipes regarding blindness, taste, texture and immunoglobulin (Ig)E antibody binding to peanut. A recipe (I) with 10% of peanut was developed evaluated and used in DBPCFC. The challenges were followed by development of a concentrated recipe (II) (15% peanut, 25% fat). Recipe II was compared with the only published recipe (III) (11% peanut, 7% fat) regarding taste, texture and availability of peanut. Recipe IV (12% peanut, 10% fat) was developed using the same methods. The binding of IgE in the recipes was measured using an inhibition method. During challenges, one patient reacted after 4 g, emphasizing the need for blinding recipes containing high doses of peanut. Evaluation between recipes II and III, only recipe II was regarded as blind by the taste panels. A tenfold lower availability of peanut protein in the recipe II was found at 50% of inhibition. Recipe IV had a better IgE binding that did not differ from the original peanut extract. The peanut taste and texture can be hidden in a challenge medium. The fat content was important for the availability of the allergenic protein in challenges. The availability of allergens must be taken into consideration when used for DBPCFC.
Feature study of hysterical blindness EEG based on FastICA with combined-channel information.
Qin, Xuying; Wang, Wei; Hu, Lintao; Wang, Xu; Yuan, Xiaojie
2015-01-01
An appropriate feature study of hysteria electroencephalograms (EEG) would provide new insights into neural mechanisms of the disease, and also make improvements in patient diagnosis and management. The objective of this paper is to provide an explanation for what causes a particular visual loss, by associating the features of hysterical blindness EEG with brain function. An idea for the novel feature extraction for hysterical blindness EEG, utilizing combined-channel information, was applied in this paper. After channels had been combined, the sliding-window-FastICA was applied to process the combined normal EEG and hysteria EEG, respectively. Kurtosis features were calculated from the processed signals. As the comparison feature, the power spectral density of normal and hysteria EEG were computed. According to the feature analysis results, a region of brain dysfunction was located at the occipital lobe, O1 and O2. Furthermore, new abnormality was found at the parietal lobe, C3, C4, P3, and P4, that provided us with a new perspective for understanding hysterical blindness. Indicated by the kurtosis results which were consistent with brain function and the clinical diagnosis, our method was found to be a useful tool to capture features in hysterical blindness EEG.
Quadratic Blind Linear Unmixing: A Graphical User Interface for Tissue Characterization
Gutierrez-Navarro, O.; Campos-Delgado, D.U.; Arce-Santana, E. R.; Jo, Javier A.
2016-01-01
Spectral unmixing is the process of breaking down data from a sample into its basic components and their abundances. Previous work has been focused on blind unmixing of multi-spectral fluorescence lifetime imaging microscopy (m-FLIM) datasets under a linear mixture model and quadratic approximations. This method provides a fast linear decomposition and can work without a limitation in the maximum number of components or end-members. Hence this work presents an interactive software which implements our blind end-member and abundance extraction (BEAE) and quadratic blind linear unmixing (QBLU) algorithms in Matlab. The options and capabilities of our proposed software are described in detail. When the number of components is known, our software can estimate the constitutive end-members and their abundances. When no prior knowledge is available, the software can provide a completely blind solution to estimate the number of components, the end-members and their abundances. The characterization of three case studies validates the performance of the new software: ex-vivo human coronary arteries, human breast cancer cell samples, and in-vivo hamster oral mucosa. The software is freely available in a hosted webpage by one of the developing institutions, and allows the user a quick, easy-to-use and efficient tool for multi/hyper-spectral data decomposition. PMID:26589467
Quadratic blind linear unmixing: A graphical user interface for tissue characterization.
Gutierrez-Navarro, O; Campos-Delgado, D U; Arce-Santana, E R; Jo, Javier A
2016-02-01
Spectral unmixing is the process of breaking down data from a sample into its basic components and their abundances. Previous work has been focused on blind unmixing of multi-spectral fluorescence lifetime imaging microscopy (m-FLIM) datasets under a linear mixture model and quadratic approximations. This method provides a fast linear decomposition and can work without a limitation in the maximum number of components or end-members. Hence this work presents an interactive software which implements our blind end-member and abundance extraction (BEAE) and quadratic blind linear unmixing (QBLU) algorithms in Matlab. The options and capabilities of our proposed software are described in detail. When the number of components is known, our software can estimate the constitutive end-members and their abundances. When no prior knowledge is available, the software can provide a completely blind solution to estimate the number of components, the end-members and their abundances. The characterization of three case studies validates the performance of the new software: ex-vivo human coronary arteries, human breast cancer cell samples, and in-vivo hamster oral mucosa. The software is freely available in a hosted webpage by one of the developing institutions, and allows the user a quick, easy-to-use and efficient tool for multi/hyper-spectral data decomposition. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Antibiotics to prevent complications following tooth extractions.
Lodi, Giovanni; Figini, Lara; Sardella, Andrea; Carrassi, Antonio; Del Fabbro, Massimo; Furness, Susan
2012-11-14
The most frequent indications for tooth extractions are dental caries and periodontal infections, and these extractions are generally done by general dental practitioners. Antibiotics may be prescribed to patients undergoing extractions to prevent complications due to infection. To determine the effect of antibiotic prophylaxis on the development of infectious complications following tooth extractions. The following electronic databases were searched: the Cochrane Oral Health Group's Trials Register (to 25 January 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 1), MEDLINE via OVID (1948 to 25 January 2012), EMBASE via OVID (1980 to 25 January 2012) and LILACS via BIREME (1982 to 25 January 2012). There were no restrictions regarding language or date of publication. We included randomised double-blind placebo-controlled trials of antibiotic prophylaxis in patients undergoing tooth extraction(s) for any indication. Two review authors independently assessed risk of bias for the included studies and extracted data. We contacted trial authors for further details where these were unclear. For dichotomous outcomes we calculated risk ratios (RR) and 95% confidence intervals (CI) using random-effects models. For continuous outcomes we used mean differences (MD) with 95% CI using random-effects models. We examined potential sources of heterogeneity. The quality of the body of evidence has been assessed using the GRADE tool. This review included 18 double-blind placebo-controlled trials with a total of 2456 participants. Five trials were assessed at unclear risk of bias, thirteen at high risk, and none at low risk of bias. Compared to placebo, antibiotics probably reduce the risk of infection in patients undergoing third molar extraction(s) by approximately 70% (RR 0.29 (95% CI 0.16 to 0.50) P < 0.0001, 1523 participants, moderate quality evidence) which means that 12 people (range 10-17) need to be treated with antibiotics to prevent one infection following extraction of impacted wisdom teeth. There is evidence that antibiotics may reduce the risk of dry socket by 38% (RR 0.62 (95% CI 0.41 to 0.95) P = 0.03, 1429 participants, moderate quality evidence) which means that 38 people (range 24-250) need to take antibiotics to prevent one case of dry socket following extraction of impacted wisdom teeth. There is also some evidence that patients who have prophylactic antibiotics may have less pain (MD -8.17 (95% CI -11.90 to -4.45) P < 0.0001, 372 participants, moderate quality evidence ) overall 7 days after the extraction compared to those receiving placebo, which may be a direct result of the lower risk of infection. There is no evidence of a difference between antibiotics and placebo in the outcomes of fever (RR 0.34, 95% CI 0.06 to 1.99), swelling (RR 0.92, 95% CI 0.65 to 1.30) or trismus (RR 0.84, 95% CI 0.42 to 1.71) 7 days after tooth extraction.Antibiotics are associated with an increase in generally mild and transient adverse effects compared to placebo (RR 1.98 (95% CI 1.10 to 3.59) P = 0.02) which means that for every 21 people (range 8-200) who receive antibiotics, an adverse effect is likely. Although general dentists perform dental extractions because of severe dental caries or periodontal infection, there were no trials identified which evaluated the role of antibiotic prophylaxis in this group of patients in this setting. All of the trials included in this review included healthy patients undergoing extraction of impacted third molars, often performed by oral surgeons. There is evidence that prophylactic antibiotics reduce the risk of infection, dry socket and pain following third molar extraction and result in an increase in mild and transient adverse effects. It is unclear whether the evidence in this review is generalisable to those with concomitant illnesses or immunodeficiency, or those undergoing the extraction of teeth due to severe caries or periodontitis. However, patients at a higher risk of infection are more likely to benefit from prophylactic antibiotics, because infections in this group are likely to be more frequent, associated with complications and be more difficult to treat. Due to the increasing prevalence of bacteria which are resistant to treatment by currently available antibiotics, clinicians should consider carefully whether treating 12 healthy patients with antibiotics to prevent one infection is likely to do more harm than good.
TMS of the occipital cortex induces tactile sensations in the fingers of blind Braille readers.
Ptito, M; Fumal, A; de Noordhout, A Martens; Schoenen, J; Gjedde, A; Kupers, R
2008-01-01
Various non-visual inputs produce cross-modal responses in the visual cortex of early blind subjects. In order to determine the qualitative experience associated with these occipital activations, we systematically stimulated the entire occipital cortex using single pulse transcranial magnetic stimulation (TMS) in early blind subjects and in blindfolded seeing controls. Whereas blindfolded seeing controls reported only phosphenes following occipital cortex stimulation, some of the blind subjects reported tactile sensations in the fingers that were somatotopically organized onto the visual cortex. The number of cortical sites inducing tactile sensations appeared to be related to the number of hours of Braille reading per day, Braille reading speed and dexterity. These data, taken in conjunction with previous anatomical, behavioural and functional imaging results, suggest the presence of a polysynaptic cortical pathway between the somatosensory cortex and the visual cortex in early blind subjects. These results also add new evidence that the activity of the occipital lobe in the blind takes its qualitative expression from the character of its new input source, therefore supporting the cortical deference hypothesis.
Treatment of Atrial Fibrillation By The Ablation Of Localized Sources
Narayan, Sanjiv M.; Krummen, David E.; Shivkumar, Kalyanam; Clopton, Paul; Rappel, Wouter-Jan; Miller, John M.
2012-01-01
Objectives We hypothesized that human atrial fibrillation (AF) may be sustained by localized sources (electrical rotors and focal impulses), whose elimination (Focal Impulse and Rotor Modulation, FIRM) may improve outcome from AF ablation. Background Catheter ablation for AF is a promising therapy, whose success is limited in part by uncertainty in the mechanisms that sustain AF. We developed a computational approach to map whether AF is sustained by several meandering waves (the prevailing hypothesis) or localized sources, then prospectively tested whether targeting patient-specific mechanisms revealed by mapping would improve AF ablation outcome. Methods We recruited 92 individuals during 107 consecutive ablation procedures for paroxysmal or persistent (72%) AF. Cases were prospectively treated, in a 2-arm 1:2 design, by ablation at sources (FIRM-Guided) followed by conventional ablation (n=36), or conventional ablation alone (n=71; FIRM-Blinded). Results Localized rotors or focal impulses were detected in 98 (97%) of 101 cases with sustained AF, each exhibiting 2.1±1.0 sources. The acute endpoint (AF termination or consistent slowing) was achieved in 86% of FIRM-guided versus 20% of FIRM-Blinded cases (p<0.001). FIRM ablation alone at the primary source terminated AF in 2.5 minutes (median; IQR 1.0–3.1). Total ablation time did not differ between groups (57.8±22.8 versus 52.1±17.8 minutes, p=0.16). During 273 days (median; IQR 132–681 days) after a single procedure, FIRM-Guided cases had higher freedom from AF (82.4% versus 44.9%; p<0.001) after a single procedure than FIRM-blinded cases with rigorous, often implanted, ECG monitoring. Adverse events did not differ between groups. CONCLUSIONS Localized electrical rotors and focal impulse sources are prevalent sustaining-mechanisms for human AF. FIRM ablation at patient-specific sources acutely terminated or slowed AF, and improved outcome. These results offer a novel mechanistic framework and treatment paradigm for AF. (ClinicalTrials.gov number, NCT01008722) PMID:22818076
Blind, Deaf, and Dumb: We Must Be Prepared to Fight for Information
2017-05-25
Blind, Deaf, and Dumb: We Must Be Prepared to Fight for Information A Monograph By LTC Stephen M. Johnson United States Army... information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and...maintaining the data needed, and completing and reviewing this collection of information . Send comments regarding this burden estimate or any other aspect
Multiple-component Decomposition from Millimeter Single-channel Data
NASA Astrophysics Data System (ADS)
Rodríguez-Montoya, Iván; Sánchez-Argüelles, David; Aretxaga, Itziar; Bertone, Emanuele; Chávez-Dagostino, Miguel; Hughes, David H.; Montaña, Alfredo; Wilson, Grant W.; Zeballos, Milagros
2018-03-01
We present an implementation of a blind source separation algorithm to remove foregrounds off millimeter surveys made by single-channel instruments. In order to make possible such a decomposition over single-wavelength data, we generate levels of artificial redundancy, then perform a blind decomposition, calibrate the resulting maps, and lastly measure physical information. We simulate the reduction pipeline using mock data: atmospheric fluctuations, extended astrophysical foregrounds, and point-like sources, but we apply the same methodology to the Aztronomical Thermal Emission Camera/ASTE survey of the Great Observatories Origins Deep Survey–South (GOODS-S). In both applications, our technique robustly decomposes redundant maps into their underlying components, reducing flux bias, improving signal-to-noise ratio, and minimizing information loss. In particular, GOODS-S is decomposed into four independent physical components: one of them is the already-known map of point sources, two are atmospheric and systematic foregrounds, and the fourth component is an extended emission that can be interpreted as the confusion background of faint sources.
An EEG blind source separation algorithm based on a weak exclusion principle.
Lan Ma; Blu, Thierry; Wang, William S-Y
2016-08-01
The question of how to separate individual brain and non-brain signals, mixed by volume conduction in electroencephalographic (EEG) and other electrophysiological recordings, is a significant problem in contemporary neuroscience. This study proposes and evaluates a novel EEG Blind Source Separation (BSS) algorithm based on a weak exclusion principle (WEP). The chief point in which it differs from most previous EEG BSS algorithms is that the proposed algorithm is not based upon the hypothesis that the sources are statistically independent. Our first step was to investigate algorithm performance on simulated signals which have ground truth. The purpose of this simulation is to illustrate the proposed algorithm's efficacy. The results show that the proposed algorithm has good separation performance. Then, we used the proposed algorithm to separate real EEG signals from a memory study using a revised version of Sternberg Task. The results show that the proposed algorithm can effectively separate the non-brain and brain sources.
Blind extraction of exoplanetary spectra
NASA Astrophysics Data System (ADS)
Morello, Giuseppe; Waldmann, Ingo P.; Tinetti, Giovanna
2016-06-01
In the last decade, remote sensing spectroscopy enabled characterization of the atmospheres of extrasolar planets. Transmission and emission spectra of tens of transiting exoplanets have been measured with multiple instruments aboard Spitzer and Hubble Space Telescopes as well as ground-based facilities, revealing the presence of atomic, ionic and molecular species in their atmospheres, and constraining their temperature and pressure profiles.Early analyses were somehow heuristic both in measuring the spectra and in their interpretation, leading to some controversies in the literature.A photometric precision of 0.01% is necessary to detect the atmospheric spectral modulations. Current observatories, except Kepler, were not designed to achieve this precision. Data reduction is necessary to minimize the effect of instrument systematics in order to achieve the target precision. In the past, parametric models have extensively been used by most teams to remove correlated noise with the aid of auxiliary information of the instrument, the so-called optical state vectors (OSVs). Such OSVs can include inter- and intra-pixel position of the star or its spectrum, instrument temperatures and inclinations, and/or other parameters. In some cases, different parameterizations led to discrepant results.We recommend the use of blind non-parametric data detrending techniques to overcome those issues. In particular, we adopt Independent Component Analysis (ICA), i.e. a blind source separation (BSS) technique to disentangle the multiple instrument systematics and astrophysical signals in transit/eclipse light curves. ICA does not require a model for the systematics, and for this reason, it can be applied to any instrument with little changes, if any. ICA-based algorithms have been applied to Spitzer/IRAC and synthetic observations in photometry (Morello et al. 2014, 2015, 2016; Morello 2015) and to Hubble/NICMOS and Spitzer/IRS in spectroscopy (Waldmann 2012, 2014, Waldmann et al. 2013) with excellent results. In this conference, I will illustrate the detrending algorithms optimized to specific instruments and the results obtained over different observations, in addition the already published ones.
Jull, Andrew; Aye, Phyu Sin
2015-06-01
To establish the reporting quality of trials published in leading nursing journals and investigate associations between CONSORT Statement or trial registration endorsment and reporting of design elements. The top 15 nursing journals were searched using Medline for randomised controlled trials published in 2012. Journals were categorised as CONSORT and trial registration promoting based on requirements of submitting authors or the journal's webpage as at January 2014. Data on sequence generation, allocation concealment, follow up, blinding, baseline equivalence and sample size calculation were extracted by one author and independently verified by the second author against source data. Seven journals were CONSORT promoting and three of these journals were also trial registration promoting. 114 citations were identified and 83 were randomised controlled trials. Eighteen trials (21.7%) were registered and those published in trial registration promoting journals were more likely to be registered (RR 2.64 95%CI 1.14-6.09). We assessed 68.7% of trials to be low risk of bias for sequence generation, 20.5% for allocation concealment, 38.6% for blinding, 55.4% for completeness of follow up and 79.5% for baseline equivalence. Trials published in CONSORT promoting journals were more likely to be at low risk of bias for blinding (RR 2.33, 95%CI 1.01-5.34) and completeness of follow up (RR 1.77, 95%CI 1.02-3.10), but journal endorsement of the CONSORT Statement or trial registration otherwise had no significant effect. Trials published in CONSORT and trial registration promoting journals were more likely to have high quality sample size calculations (RR 2.91, 95%CI 1.18-7.19 and RR 1.69, 95%CI 1.08-2.64, respectively). Simple endorsement of the CONSORT Statement and trials registration is insufficient action to encourage improvement of the quality of trial reporting across the most important of trial design elements. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chaste tree (Vitex agnus-castus)--pharmacology and clinical indications.
Wuttke, W; Jarry, H; Christoffel, V; Spengler, B; Seidlová-Wuttke, D
2003-05-01
Extracts of the fruits of chaste tree (Vitex agnus castus = AC) are widely used to treat premenstrual symptoms. Double-blind placebo-controlled studies indicate that one of the most common premenstrual symptoms, i.e. premenstrual mastodynia (mastalgia) is beneficially influenced by an AC extract. In addition, numerous less rigidly controlled studies indicate that AC extracts have also beneficial effects on other psychic and somatic symptoms of the PMS. Premenstrual mastodynia is most likely due to a latent hyperprolactinemia, i.e. patients release more than physiologic amounts of prolactin in response to stressful situations and during deep sleep phases which appear to stimulate the mammary gland. Premenstrually this unphysiological prolactin release is so high that the serum prolactin levels often approach heights which are misinterpreted as prolactinomas. Since AC extracts were shown to have beneficial effects on premenstrual mastodynia serum prolactin levels in such patients were also studied in one double-blind, placebo-controlled clinical study. Serum prolactin levels were indeed reduced in the patients treated with the extract. The search for the prolactin-suppressive principle(s) yielded a number of compounds with dopaminergic properties: they bound to recombinant DA2-receptor protein and suppressed prolactin release from cultivated lactotrophs as well as in animal experiments. The search for the chemical identity of the dopaminergic compounds resulted in isolation of a number of diterpenes of which some clerodadienols were most important for the prolactin-suppressive effects. They were almost identical in their prolactin-suppressive properties than dopamine itself. Hence, it is concluded that dopaminergic compounds present in Vitex agnus castus are clinically the important compounds which improve premenstrual mastodynia and possibly also other symptoms of the premenstrual syndrome.
Bousquet, J; Hejjaoui, A; Skassa-Brociek, W; Guérin, B; Maasch, H J; Dhivert, H; Michel, F B
1987-10-01
Forty-five grass pollen-allergic patients were randomly assigned to three groups according to their skin test and RAST sensitivities and the severity of seasonal rhinitis. Eleven patients were treated with placebo (group 1), 19 patients (group 2) were treated with a six-mixed grass-pollen allergoid prepared by mild formalinization with a two-step procedure, and 15 other patients were treated with a standardized orchard grass-pollen extract (group 3). Because of a different immunotherapy schedule, only patients placed in groups 1 and 2 received the extracts in a double-blind fashion. Rush immunotherapy was performed in 3 to 6 days, and the maintenance dose was subsequently administered weekly for 4 weeks and every 2 weeks until the end of the grass-pollen season. During the season, a coseasonal treatment was administered. Systemic reactions occurred during the rush protocol in 36.8% of patients treated with allergoid and 20% of patients who received the standardized extract. Only patients treated with allergoid had systemic reactions during maintenance dose. The reactions observed with the standardized extract were more severe. Total doses of allergoid ranged from 2350 to 13,500 protein nitrogen units. Symptoms and medication scores during the peak of the season were analyzed. Patients treated with the standardized allergen had a significant reduction of the number of days of symptoms during the month of June (9.5 +/- 6.7 days; p less than 0.005) and of medication scores (1.3 +/- 1.4; p less than 0.01) compared to patients receiving placebo (19.4 +/- 8.1 days; medication score, 2.8 +/- 2.1).(ABSTRACT TRUNCATED AT 250 WORDS)
Independent Component Analysis applied to Ground-based observations
NASA Astrophysics Data System (ADS)
Martins-Filho, Walter; Griffith, Caitlin; Pearson, Kyle; Waldmann, Ingo; Alvarez-Candal, Alvaro; Zellem, Robert Thomas
2018-01-01
Transit measurements of Jovian-sized exoplanetary atmospheres allow one to study the composition of exoplanets, largely independent of the planet’s temperature profile. However, measurements of hot-Jupiter transits must archive a level of accuracy in the flux to determine the spectral modulation of the exoplanetary atmosphere. To accomplish this level of precision, we need to extract systematic errors, and, for ground-based measurements, the effects of Earth’s atmosphere, from signal due to the exoplanet, which is several orders of magnitude smaller. The effects of the terrestrial atmosphere and some of the time-dependent systematic errors of ground-based transit measurements are treated mainly by dividing the host star by a reference star at each wavelength and time step of the transit. Recently, Independent Component Analysis (ICA) have been used to remove systematics effects from the raw data of space-based observations (Waldmann, 2014, 2012; Morello et al., 2016, 2015). ICA is a statistical method born from the ideas of the blind-source separations studies, which can be used to de-trend several independent source signals of a data set (Hyvarinen and Oja, 2000). This technique requires no additional prior knowledge of the data set. In addition, this technique has the advantage of requiring no reference star. Here we apply the ICA to ground-based photometry of the exoplanet XO-2b recorded by the 61” Kuiper Telescope and compare the results of the ICA to those of a previous analysis from Zellem et al. (2015), which does not use ICA. We also simulate the effects of various conditions (concerning the systematic errors, noise and the stability of object on the detector) to determine the conditions under which an ICA can be used with high precision to extract the light curve of exoplanetary photometry measurements
Independent Component Analysis applied to Ground-based observations
NASA Astrophysics Data System (ADS)
Martins-Filho, Walter; Griffith, Caitlin Ann; Pearson, Kyle; Waldmann, Ingo; Alvarez-Candal, Alvaro; Zellem, Robert
2017-10-01
Transit measurements of Jovian-sized exoplanetary atmospheres allow one to study the composition of exoplanets, largely independent of the planet’s temperature profile. However, measurements of hot-Jupiter transits must archive a level of accuracy in the flux to determine the spectral modulations of the exoplanetary atmosphere. To accomplish this level of precision, we need to extract systematic errors, and, for ground-based measurements, the effects of Earth’s atmosphere, from signal due to the exoplanet, which is several orders of magnitudes smaller.The effects of the terrestrial atmosphere and some of the time dependent systematic errors of ground-based transit measurements are treated mainly by dividing the host star by a reference star at each wavelength and time step of the transit. Recently, Independent Component Analyses (ICA) have been used to remove systematics effects from the raw data of space-based observations (Waldmann, 2014, 2012; Morello et al., 2016, 2015). ICA is a statistical method born from the ideas of the blind-source separations studies, which can be used to de-trend several independent source signals of a data set (Hyvarinen and Oja, 2000). This technique requires no additional prior knowledge of the data set. In addition this technique has the advantage of requiring no reference star.Here we apply the ICA to ground-based photometry of the exoplanet XO-2b recorded by the 61” Kuiper Telescope and compare the results of the ICA to those of a previous analysis from Zellem et al. (2015), which does not use ICA. We also simulate the effects of various conditions (concerning the systematic errors, noise and the stability of object on the detector) to determine the conditions under which an ICA can be used with high precision to extract the light curve of exoplanetary photometry measurements.
Strategic issues in preventing cataract blindness in developing countries.
Ellwein, L. B.; Kupfer, C.
1995-01-01
Cataract blindness is a public health problem of major proportions in developing countries. Intracapsular cataract extraction with aphakic spectacles has been the standard surgical technique for restoring sight. Because of image magnification in the operated eye, however, the result in unilaterally blind patients is less than satisfactory. Fortunately, with the availability of low-cost intraocular lenses (IOL) and ophthalmologists trained in extracapsular surgery, it is now practical to intervene successfully in the unilateral case. The need for increased attention on the quality of the visual high prevalence of cataract blindness in developing countries and an increasing cataract incidence due to an aging population require substantial increases in surgical volume. The third issue relates to cost. If significant increases in surgical volume and quality of outcomes are to be realized without an increased need for external funding, service delivery must be made more efficient. The expansion of IOL surgery for unilateral blindness is a favourable trend in ensuring financial sustainability of delivery systems; patients can be operated on while still economically productive and able to pay rather than waiting for bilateral blindness and a less favourable economic and social impact. If the quality, volume, and cost issues are to be successfully addressed, operational and structural changes to eye care delivery systems are necessary. These changes can be effected through training, technology introduction, management of facilities, social marketing, organizational partnerships, and evaluation. With improved understanding of the critical factors in successful models their widespread replication will be facilitated. PMID:8846495
Direction of arrival estimation using blind separation of sources
NASA Astrophysics Data System (ADS)
Hirari, Mehrez; Hayakawa, Masashi
1999-05-01
The estimation of direction of arrival (DOA) and polarization of an incident electromagnetic (EM) wave is of great importance in many applications. In this paper we propose a new approach for the estimation of DOA for polarized EM waves using blind separation of sources. In this approach we use a vector sensor, a sensor whose output is a complete set of the EM field components of the irradiating wave, and we reconstruct the waveforms of all the original signals that is, all the EM components of the sources' fields. From the waveform of each source we calculate its amplitude and phase and consequently calculate its DOA and polarization using the field analysis method. The separation of sources is conducted iteratively using a recurrent Hopfield-like single-layer neural network. The simulation results for two sources have been investigated. We have considered coherent and incoherent sources and also the case of varying DOAs vis-ā-vis the sensor and a varying polarization. These are cases seldom treated by other approaches even though they exist in real-world applications. With the proposed method we have obtained almost on-time tracking for the DOA and polarization of any incident sources with a significant reduction of both memory and computation costs.
PHLUX: Photographic Flux Tools for Solar Glare and Flux
DOE Office of Scientific and Technical Information (OSTI.GOV)
2010-12-02
A web-based tool to a) analytically and empirically quantify glare from reflected light and determine the potential impact (e.g., temporary flash blindness, retinal burn), and b) produce flux maps for central receivers. The tool accepts RAW digital photographs of the glare source (for hazard assessment) or the receiver (for flux mapping), as well as a photograph of the sun for intensity and size scaling. For glare hazard assessment, the tool determines the retinal irradiance (W/cm2) and subtended source angle for an observer and plots the glare source on a hazard spectrum (i.e., low-potential for flash blindness impact, potential for flashmore » blindness impact, retinal burn). For flux mapping, the tool provides a colored map of the receiver scaled by incident solar flux (W/m2) and unwraps the physical dimensions of the receiver while accounting for the perspective of the photographer (e.g., for a flux map of a cylindrical receiver, the horizontal axis denotes receiver angle in degrees and the vertical axis denotes vertical position in meters; for a flat panel receiver, the horizontal axis denotes horizontal position in meters and the vertical axis denotes vertical position in meters). The flux mapping capability also allows the user to specify transects along which the program plots incident solar flux on the receiver.« less
20 CFR 404.1519h - Your treating source.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Your treating source. 404.1519h Section 404.1519h Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY INSURANCE (1950- ) Determining Disability and Blindness Standards for the Type of Referral and for Report...
Aziz, Tavga Ahmed; Hussain, Saad Abdulrahman; Mahwi, Taha Othman; Ahmed, Zheen Aorahman; Rahman, Heshu Sulaiman; Rasedee, Abdullah
2018-01-01
Background and aim Type 2 diabetes mellitus (T2DM) is one of the major diseases confronting the health care systems. In diabetes mellitus (DM), combined use of oral hypoglycemic medications has been shown to be more effective than metformin (Met) alone in glycemic control. This study determined the effects of Ginkgo biloba (GKB) extract as an adjuvant to Met in patients with uncontrolled T2DM. Subjects and methods Sixty T2DM patients were recruited in a randomized, placebo-controlled, double-blinded, and multicenter trial. The patients, currently using Met, were randomly grouped into those treated with either GKB extract (120 mg/day) or placebo (starch, 120 mg/day) for 90 days. Blood glycated hemoglobin (HbA1c), fasting serum glucose, serum insulin, body mass index (BMI), waist circumference (WC), insulin resistance, and visceral adiposity index (VAI) were determined before (baseline) and after 90 days of GKB extract treatment. Results GKB extract significantly decreased blood HbA1c (7.7%±1.2% vs baseline 8.6%±1.6%, P<0.001), fasting serum glucose (154.7±36.1 mg/dL vs baseline 194.4±66.1 mg/dL, P<0.001) and insulin (13.4±7.8 μU/mL vs baseline 18.5±8.9 μU/mL, P=0.006) levels, BMI (31.6±5.1 kg/m2 vs baseline 34.0±6.0 kg/m2, P<0.001), waist WC (102.6±10.5 cm vs baseline 106.0±10.9 cm, P<0.001), and VAI (158.9±67.2 vs baseline 192.0±86.2, P=0.007). GKB extract did not negatively impact the liver, kidney, or hematopoietic functions. Conclusion GKB extract as an adjuvant was effective in improving Met treatment outcomes in T2DM patients. Thus, it is suggested that GKB extract is an effective dietary supplement for the control of DM in humans. PMID:29670330
Obtention and characterization of phenolic extracts from different cocoa sources.
Ortega, Nàdia; Romero, Maria-Paz; Macià, Alba; Reguant, Jordi; Anglès, Neus; Morelló, José-Ramón; Motilva, Maria-Jose
2008-10-22
The aim of this study was to evaluate several cocoa sources to obtain a rich phenol extract for use as an ingredient in the food industry. Two types of phenolic extracts, complete and purified, from different cocoa sources (beans, nibs, liquor, and cocoa powder) were investigated. UPLC-MS/MS was used to identify and quantify the phenolic composition of the extracts, and the Folin-Ciocalteu and vanillin assays were used to determine the total phenolic and flavan-3-ol contents, respectively. The DPPH and ORAC assays were used to measure their antioxidant activity. The results of the analysis of the composition of the extracts revealed that the major fraction was procyanidins, followed by flavones and phenolic acids. From the obtained results, the nib could be considered the most interesting source for obtaining a rich phenolic cocoa extract because of its rich phenolic profile content and high antioxidant activity in comparison with the other cocoa sources.
Variational Bayesian Learning for Wavelet Independent Component Analysis
NASA Astrophysics Data System (ADS)
Roussos, E.; Roberts, S.; Daubechies, I.
2005-11-01
In an exploratory approach to data analysis, it is often useful to consider the observations as generated from a set of latent generators or "sources" via a generally unknown mapping. For the noisy overcomplete case, where we have more sources than observations, the problem becomes extremely ill-posed. Solutions to such inverse problems can, in many cases, be achieved by incorporating prior knowledge about the problem, captured in the form of constraints. This setting is a natural candidate for the application of the Bayesian methodology, allowing us to incorporate "soft" constraints in a natural manner. The work described in this paper is mainly driven by problems in functional magnetic resonance imaging of the brain, for the neuro-scientific goal of extracting relevant "maps" from the data. This can be stated as a `blind' source separation problem. Recent experiments in the field of neuroscience show that these maps are sparse, in some appropriate sense. The separation problem can be solved by independent component analysis (ICA), viewed as a technique for seeking sparse components, assuming appropriate distributions for the sources. We derive a hybrid wavelet-ICA model, transforming the signals into a domain where the modeling assumption of sparsity of the coefficients with respect to a dictionary is natural. We follow a graphical modeling formalism, viewing ICA as a probabilistic generative model. We use hierarchical source and mixing models and apply Bayesian inference to the problem. This allows us to perform model selection in order to infer the complexity of the representation, as well as automatic denoising. Since exact inference and learning in such a model is intractable, we follow a variational Bayesian mean-field approach in the conjugate-exponential family of distributions, for efficient unsupervised learning in multi-dimensional settings. The performance of the proposed algorithm is demonstrated on some representative experiments.
Developmental vision determines the reference frame for the multisensory control of action.
Röder, Brigitte; Kusmierek, Anna; Spence, Charles; Schicke, Tobias
2007-03-13
Both animal and human studies suggest that action goals are defined in external coordinates regardless of their sensory modality. The present study used an auditory-manual task to test whether the default use of such an external reference frame is innately determined or instead acquired during development because of the increasing dominance of vision over manual control. In Experiment I, congenitally blind, late blind, and age-matched sighted adults had to press a left or right response key depending on the bandwidth of pink noise bursts presented from either the left or right loudspeaker. Although the spatial location of the sounds was entirely task-irrelevant, all groups responded more efficiently with uncrossed hands when the sound was presented from the same side as the responding hand ("Simon effect"). This effect reversed with crossed hands only in the congenitally blind: They responded faster with the hand that was located contralateral to the sound source. In Experiment II, the instruction to the participants was changed: They now had to respond with the hand located next to the sound source. In contrast to Experiment I ("Simon-task"), this task required an explicit matching of the sound's location with the position of the responding hand. In Experiment II, the congenitally blind participants showed a significantly larger crossing deficit than both the sighted and late blind adults. This pattern of results implies that developmental vision induces the default use of an external coordinate frame for multisensory action control; this facilitates not only visual but also auditory-manual control.
Buckle, M; Lee, A; Mohamed, Q; Fletcher, E; Sallam, A; Healy, R; Stratton, I; Tufail, A; Johnston, R L
2015-03-01
This study aimed to evaluate the incidence and prevalence of blindness, sight impairment, and other visual acuity (VA) states in patients receiving ranibizumab for neovascular age-related macular degeneration (nAMD) in Gloucestershire. Serial VA and injection data for all treatment-naive patients receiving their first intravitreal injections of ranibizumab for nAMD in the Gloucestershire National Health Service Ophthalmology department between 2008 and 2010 were extracted from an electronic medical record system. The prevalence of blindness (VA in the better-seeing eye ≤25 Early Treatment Diabetic Retinopathy Study (ETDRS) letters) at the time of first intravitreal injection was 0.8%, increasing to 3.5% after 3 years. The prevalence of sight impairment (VA in the better-seeing eye 26-39 ETDRS letters) increased from 4.1% at baseline to 5.5% after 3 years. The incidence of initiating ranibizumab treatment for nAMD in people aged ≥50 years in Gloucestershire was 111 people per 100 000 population in 2009, and 97 people in 2010. The incidence of patients meeting the visual criteria for blindness and sight impairment registration from treated nAMD in people aged ≥50 years in Gloucestershire was 3.5 and 9.7 people, respectively per 100 000 population in 2010. This is the first real-world study on the incidence and prevalence of eligibility for blindness and sight impairment registration in treated nAMD in the UK based on VA data. The incidence and prevalence of eligibility for certification of blindness or sight impairment in patients treated with ranibizumab for nAMD is low in Gloucestershire, with only 3.6% of the incident population progressing to blindness in 2010.
Efficient source separation algorithms for acoustic fall detection using a microsoft kinect.
Li, Yun; Ho, K C; Popescu, Mihail
2014-03-01
Falls have become a common health problem among older adults. In previous study, we proposed an acoustic fall detection system (acoustic FADE) that employed a microphone array and beamforming to provide automatic fall detection. However, the previous acoustic FADE had difficulties in detecting the fall signal in environments where interference comes from the fall direction, the number of interferences exceeds FADE's ability to handle or a fall is occluded. To address these issues, in this paper, we propose two blind source separation (BSS) methods for extracting the fall signal out of the interferences to improve the fall classification task. We first propose the single-channel BSS by using nonnegative matrix factorization (NMF) to automatically decompose the mixture into a linear combination of several basis components. Based on the distinct patterns of the bases of falls, we identify them efficiently and then construct the interference free fall signal. Next, we extend the single-channel BSS to the multichannel case through a joint NMF over all channels followed by a delay-and-sum beamformer for additional ambient noise reduction. In our experiments, we used the Microsoft Kinect to collect the acoustic data in real-home environments. The results show that in environments with high interference and background noise levels, the fall detection performance is significantly improved using the proposed BSS approaches.
Gómez-Arbeláez, Diego; Lahera, Vicente; Oubiña, Pilar; Valero-Muñoz, Maria; de las Heras, Natalia; Rodríguez, Yudy; García, Ronald Gerardo; Camacho, Paul Anthony; López-Jaramillo, Patricio
2013-01-01
Background. Garlic (Allium sativum) has been shown to have important benefits in individuals at high cardiovascular risk. The aim of the present study was to evaluate the effects of the administration of aged garlic extract (AGE) on the risk factors that constitute the cluster of metabolic syndrome (MS). Methods and Design. Double-blind, crossover, randomized, placebo-controlled clinical trial to assess the effect of 1.2 g/day of AGE (Kyolic), for 24 weeks of treatment (12 weeks of AGE and 12 weeks of placebo), on subjects with MS. Results. The administration of AGE increased the plasma levels of adiponectin (P = 0.027). No serious side effects associated with the intervention were reported. Conclusion. The present results have shown for the first time that the administration of AGE for 12 weeks increased plasma adiponectin levels in patients with MS. This suggests that AGE might be a useful, novel, nonpharmacological therapeutic intervention to increase adiponectin and to prevent cardiovascular (CV) complications in individuals with MS. PMID:23533302
Su, Yushan; Hung, Hayley
2010-11-01
Measurements of semi-volatile organic chemicals (SVOCs) were compared among 21 laboratories from 7 countries through the analysis of standards, a blind sample, an air extract, and an atmospheric dust sample. Measurement accuracy strongly depended on analytes, laboratories, and types of standards and samples. Intra-laboratory precision was generally good with relative standard deviations (RSDs) of triplicate injections <10% and with median differences of duplicate samples between 2.1 and 22%. Inter-laboratory variability, measured by RSDs of all measurements, was in the range of 2.8-58% in analyzing standards, and 6.9-190% in analyzing blind sample and air extract. Inter-laboratory precision was poorer when samples were subject to cleanup processes, or when SVOCs were quantified at low concentrations. In general, inter-laboratory differences up to a factor of 2 can be expected to analyze atmospheric SVOCs. When comparing air measurements from different laboratories, caution should be exercised if the data variability is less than the inter-laboratory differences. 2010. Published by Elsevier Ltd. All rights reserved.
Lee, You Jin; Ahn, Youngsook; Kwon, Oran; Lee, Mee Youn; Lee, Choong Hwan; Lee, Sungyoung; Park, Taesung; Kwon, Sung Won; Kim, Ji Yeon
2017-01-18
In the present study, we evaluated the antioxidative and anti-inflammatory effects of an aqueous extract of wolfberry fruit (WBE) in mild hypercholesterolemic and overweight subjects. This study was a double-blind randomized trial of two parallel groups of free-living subjects (n = 53). The participants consumed the contents of an 80 mL pouch containing 13.5 g WBE or placebo after one meal per day over an 8-week period. Following 8 weeks of WBE supplementation, we observed a slight but significant decrease in erythrocyte superoxide dismutase activity and an increase in catalase activity. Furthermore, to assess endogenous DNA damage in lymphocytes, the alkaline comet assay was performed, showing that the percentage of DNA in the tail was significantly decreased by 8-week WBE intake. Additionally, the proportion of significantly deregulated mRNAs related to oxidative or inflammatory stress was considerably higher in the WBE intake group. The present data indicate that WBE intake has antioxidative and anti-inflammatory effects in overweight and hypercholesterolemic subjects by modulating mRNA expression.
Choi, Jae-Suk; Park, Jae Beom; Moon, Woi-Sook; Moon, Jin-Nam; Son, Sang Wook; Kim, Mi-Ryung
2015-01-01
We conducted a 16-week double-blind randomized controlled single-center trial to evaluate the safety and efficacy of dermal rice bran supercritical CO2 extract (RB-SCE) in the treatment of androgenic alopecia. Fifty alopecia patients were randomly assigned to the experimental and placebo groups. The experimental group received a dermal application of 0.5% RB-SCE (8 mL/d) to the head skin for 16 weeks while the control group received a dermal application of placebo. Changes in hair count, diameter, and density were evaluated with a Folliscope(®). Patient satisfaction was evaluated via questionnaire and clinical photographs were rated by dermatologists. The results showed that RB-SCE significantly increased hair density and hair diameter in male subjects. Patient satisfaction and the evaluation of photographs by dermatologists also confirmed the effectiveness of RB-SCE in the treatment of alopecia. No adverse reactions related to RB-SCE were reported. Therefore, RB-SCE shows promise for use in functional cosmetics and pharmaceuticals.
Predel, H G; Giannetti, B; Koll, R; Bulitta, M; Staiger, C
2005-11-01
In the treatment of minor blunt injuries several topical drugs are known to have anti-inflammatory and analgesic properties. They represent, however, two fundamentally different major pharmacological therapy approaches: the "chemical-synthetical" and the "phytotherapeutical" approach. The main objective of this trial (CODEC_2004) was to compare the efficacy and tolerability of an ointment of Comfrey extract (Extr. Rad. Symphyti) with that of a Diclofenac gel in the treatment of acute unilateral ankle sprain (distortion). In a single-blind, controlled, randomized, parallel-group, multicenter and confirmatory clinical trial outpatients with acute unilateral ankle sprains (n=164, mean age 29.0 years, 47.6% female) received either a 6 cm long ointment layer of Kytta-Salbe f (Comfrey extract) (n=82) or of Diclofenac gel containing 1.16 g of diclofenac diethylamine salt (n=82) for 7 +/- 1 days, four times a day. Primary variable was the area-under-the-curve (AUC) of the pain reaction to pressure on the injured area measured by a calibrated caliper (tonometer). Secondary variables were the circumference of the joint (swelling; figure-of-eight method), the individual spontaneous pain sensation at rest and at movement according to a Visual Analogue Scale (VAS), the judgment of impaired movements of the injured joint by the method of "neutral-zero", consumption of rescue medication (paracetamol), as well as the global efficacy evaluation and the global assessment of tolerability (both by physician and patient, 4 ranks). In this study the primary variable was also to be validated prospectively. It was confirmatorily shown that Comfrey extract is non-inferior to diclofenac. The 95% confidence interval for the AUC (Comfrey extract minus Diclofenac gel) was 19.01-103.09h*N/cm2 and was completely above the margin of non-inferiority. Moreover, the results of the primary and secondary variables indicate that Comfrey extract may be superior to Diclofenac gel.
41 CFR 51-5.2 - Mandatory source requirement.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Mandatory source requirement. 51-5.2 Section 51-5.2 Public Contracts and Property Management Other Provisions Relating to Public Contracts COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED 5-CONTRACTING...
NASA Astrophysics Data System (ADS)
Franzen, P.; Gutser, R.; Fantz, U.; Kraus, W.; Falter, H.; Fröschle, M.; Heinemann, B.; McNeely, P.; Nocentini, R.; Riedl, R.; Stäbler, A.; Wünderlich, D.
2011-07-01
The ITER neutral beam system requires a negative hydrogen ion beam of 48 A with an energy of 0.87 MeV, and a negative deuterium beam of 40 A with an energy of 1 MeV. The beam is extracted from a large ion source of dimension 1.9 × 0.9 m2 by an acceleration system consisting of seven grids with 1280 apertures each. Currently, apertures with a diameter of 14 mm in the first grid are foreseen. In 2007, the IPP RF source was chosen as the ITER reference source due to its reduced maintenance compared with arc-driven sources and the successful development at the BATMAN test facility of being equipped with the small IPP prototype RF source ( {\\sim}\\frac{1}{8} of the area of the ITER NBI source). These results, however, were obtained with an extraction system with 8 mm diameter apertures. This paper reports on the comparison of the source performance at BATMAN of an ITER-relevant extraction system equipped with chamfered apertures with a 14 mm diameter and 8 mm diameter aperture extraction system. The most important result is that there is almost no difference in the achieved current density—being consistent with ion trajectory calculations—and the amount of co-extracted electrons. Furthermore, some aspects of the beam optics of both extraction systems are discussed.
Nonlinear Blind Compensation for Array Signal Processing Application
Ma, Hong; Jin, Jiang; Zhang, Hua
2018-01-01
Recently, nonlinear blind compensation technique has attracted growing attention in array signal processing application. However, due to the nonlinear distortion stemming from array receiver which consists of multi-channel radio frequency (RF) front-ends, it is too difficult to estimate the parameters of array signal accurately. A novel nonlinear blind compensation algorithm aims at the nonlinearity mitigation of array receiver and its spurious-free dynamic range (SFDR) improvement, which will be more precise to estimate the parameters of target signals such as their two-dimensional directions of arrival (2-D DOAs). Herein, the suggested method is designed as follows: the nonlinear model parameters of any channel of RF front-end are extracted to synchronously compensate the nonlinear distortion of the entire receiver. Furthermore, a verification experiment on the array signal from a uniform circular array (UCA) is adopted to testify the validity of our approach. The real-world experimental results show that the SFDR of the receiver is enhanced, leading to a significant improvement of the 2-D DOAs estimation performance for weak target signals. And these results demonstrate that our nonlinear blind compensation algorithm is effective to estimate the parameters of weak array signal in concomitance with strong jammers. PMID:29690571
A complete passive blind image copy-move forensics scheme based on compound statistics features.
Peng, Fei; Nie, Yun-ying; Long, Min
2011-10-10
Since most sensor pattern noise based image copy-move forensics methods require a known reference sensor pattern noise, it generally results in non-blinded passive forensics, which significantly confines the application circumstances. In view of this, a novel passive-blind image copy-move forensics scheme is proposed in this paper. Firstly, a color image is transformed into a grayscale one, and wavelet transform based de-noising filter is used to extract the sensor pattern noise, then the variance of the pattern noise, the signal noise ratio between the de-noised image and the pattern noise, the information entropy and the average energy gradient of the original grayscale image are chosen as features, non-overlapping sliding window operations are done to the images to divide them into different sub-blocks. Finally, the tampered areas are detected by analyzing the correlation of the features between the sub-blocks and the whole image. Experimental results and analysis show that the proposed scheme is completely passive-blind, has a good detection rate, and is robust against JPEG compression, noise, rotation, scaling and blurring. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Holubarsch, C J; Colucci, W S; Meinertz, T; Gaus, W; Tendera, M
2000-12-01
SPICE is the first, international, randomized, placebo-controlled, double-blind study to investigate the influence of the herbal drug Crataegus Special Extract WS 1442 (hawthorn leaves with flowers) on mortality of patients suffering from congestive heart failure. In vitro and experimental animal studies have suggested the following pharmacological modes of action of standardized Crataegus extracts: (1) cAMP-independent positive inotropy; (2) peripheral and coronary vasodilation; (3) protection against ischemia-induced ventricular arrhythmias; (4) antioxidative properties; and (5) anti-inflammatory effects. In this randomized, placebo-controlled, double-blind, international trial (approximately 120 investigational centers in seven European countries), up to 2300 patients with congestive heart failure, New York Heart Association class II and III and markedly impaired left ventricular function, will be enrolled and treated over a period of 24 months. During this time patients receive either two film-coated tablets of 450 mg of the Special Extract WS 1442 standardized to 84.3 mg of oligomeric procyanidines or matched placebo per day in addition to standard therapy for congestive heart failure, such as diuretics, digoxin or digitoxin, beta-adrenoceptor blockers and angiotensin-converting-enzyme inhibitors. The primary outcome variable is the combined endpoint of cardiac death, non-lethal myocardial infarction, and hospitalization due to progression of heart failure. Secondary outcome variables are total mortality, exercise duration, echocardiographic parameters, quality of life as well as pharmacoeconomic parameters. The first patient was included in October 1998. The trial is expected to be completed at the end of 2002.
Xu, Zhengyuan; Ding, Haipeng; Sadler, Brian M; Chen, Gang
2008-08-15
Motivated by recent advances in solid-state incoherent ultraviolet sources and solar blind detectors, we study communication link performance over a range of less than 1 km with a bit error rate (BER) below 10(-3) in solar blind non-line-of-sight situation. The widely adopted yet complex single scattering channel model is significantly simplified by means of a closed-form expression for tractable analysis. Path loss is given as a function of transceiver geometry as well as atmospheric scattering and attenuation and is compared with experimental data for model validation. The BER performance of a shot-noise-limited receiver under this channel model is demonstrated.
Blind speech separation system for humanoid robot with FastICA for audio filtering and separation
NASA Astrophysics Data System (ADS)
Budiharto, Widodo; Santoso Gunawan, Alexander Agung
2016-07-01
Nowadays, there are many developments in building intelligent humanoid robot, mainly in order to handle voice and image. In this research, we propose blind speech separation system using FastICA for audio filtering and separation that can be used in education or entertainment. Our main problem is to separate the multi speech sources and also to filter irrelevant noises. After speech separation step, the results will be integrated with our previous speech and face recognition system which is based on Bioloid GP robot and Raspberry Pi 2 as controller. The experimental results show the accuracy of our blind speech separation system is about 88% in command and query recognition cases.
Disparities in access to medical care for individuals with vision impairment.
Spencer, Christine; Frick, Kevin; Gower, Emily W; Kempen, John H; Wolff, Jennifer L
2009-01-01
We investigated the relationship between blindness and vision impairment and access to medical care. Pooled data from the Medical Expenditure Panel Survey (MEPS) years 2002-2004 were used to identify non-institutionalized individuals over the age of 40 with either self-reported blindness, vision impairment, or no vision impairment (n = 40,643). Differences in access to care measures by vision status were assessed, after adjusting for the complex sampling design of the MEPS, using either two-sided z-tests or two-sided t-tests. Individuals with blindness and vision impairment report having more access problems related to cost of care, availability of insurance coverage, transportation issues, and refusal of services by providers, although they do not report lower rates of having a usual source of care compared to those without vision impairment. The results suggest that access to care for individuals with blindness and vision impairment is problematic, for reasons that are amenable to policy interventions.
Mao, Jun J; Li, Qing S.; Soeller, Irene; Rockwell, Kenneth; Xie, Sharon X; Amsterdam, Jay D.
2017-01-01
Background Anxiety symptoms are among the most common reasons for consumers to use Complementary and Alternative Medicine (CAM) therapy. Although many botanicals have been proposed as putative remedies for anxiety symptoms, there has been a paucity of controlled trials of these remedies. A preliminary study of the anxiolytic effect of Chamomile (Matricaria recutita) in humans suggests that chamomile may have anxiolytic and antidepressant activity. We now seek to conduct a 5-year randomized, double-blind, placebo-substitution study to examine the short and long-term safety and efficacy of chamomile extract in Generalized Anxiety Disorder (GAD). Methods/Design 180 subjects with moderate to severe GAD will receive initial open-label pharmaceutical-grade chamomile extract 500–1,500 mg daily for 8 weeks. Responders to treatment who remain well for an additional 4 weeks of consolidation therapy, will be randomized to double-blind continuation therapy with either chamomile extract 500–1,500 mg daily or placebo for an additional 26 weeks. The primary outcome will be the time to relapse during study continuation therapy in each treatment condition. Secondary outcomes will include the proportion of subjects in each treatment condition who relapse, as well as the proportion of subjects with treatment-emergent adverse events. Quality of life ratings will also be compared between treatment conditions during short and long-term therapy. Discussion Many individuals with mental disorders decline conventional therapy and seek CAM therapies for their symptoms. Thus, the identification of effective CAM therapy is of relevance to reducing the burden of mental illness. This study builds upon our prior findings of significant superiority of chamomile versus placebo in reducing GAD symptoms. We now extend these preliminary findings by conducting a randomized long-term safety and efficacy study of chamomile in GAD. PMID:29057164
Schapowal, Andreas
2005-06-01
Intermittent allergic rhinitis (IAR) causes patients distress and impairs their work performance and quality of life. A variety of medicines are used by sufferers whose anguish frequently leads to trying new treatments, increasingly from herbal sources. Prospective, randomized, double-blind, parallel group comparison study of Butterbur extract (Ze 339; 8 mg total petasine; one tablet thrice-daily), fexofenadine (Telfast 180, one tablet once-daily) and placebo in 330 patients. Protocol and analysis were according to the latest guidelines on new treatments for allergic rhinitis. The primary efficacy variable was a change in symptoms from baseline to endpoint during daytime. The secondary efficacy variables were: (a) as per primary variable (evening/night); (b) Physician's global assessment; (c) Responder rates. Safety was closely monitored. Both active treatments were individually significantly superior to placebo (p<0.001) in improving symptoms of IAR, while there were no differences between the two active treatments (p=0.37). Superiority to placebo was similarly shown during the evening/night (p<0.001), by physicians' own assessment and by responder rates. Both treatments were well tolerated. Butterbur Ze 339 and Fexofenadine are comparably efficacious relative to placebo. Despite being a herbal drug, Butterbur Ze 339 has now been subject to a series of well controlled trials and should be considered as an alternative treatment for IAR. Copyright (c) 2005 John Wiley & Sons, Ltd.
Obtaining lutein-rich extract from microalgal biomass at preparative scale.
Fernández-Sevilla, José M; Fernández, F Gabriel Acién; Grima, Emilio Molina
2012-01-01
Lutein extracts are in increasing demand due to their alleged role in the prevention of degenerative disorders such as age-related macular degeneration (AMD). Lutein extracts are currently obtained from plant sources, but microalgae have been demonstrated to be a competitive source likely to become an alternative. The extraction of lutein from microalgae posesses specific problems that arise from the different structure and composition of the source biomass. Here is presented a method for the recovery of lutein-rich carotenoid extracts from microalgal biomass in the kilogram scale.
Detection of Apical Root Cracks Using Spectral Domain and Swept-source Optical Coherence Tomography.
de Oliveira, Bruna Paloma; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Gomes, Anderson Stevens Leonidas; Heck, Richard John; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes
2017-07-01
This study aimed to evaluate the ability of 2 optical coherence tomographic (OCT) systems to detect apical dentinal microcracks. Twenty extracted human single-rooted mandibular incisors were selected. After root canal preparation with an R40 Reciproc file (VDW, Munich, Germany), the specimens presenting apical microcracks were identified using micro-computed tomographic (micro-CT) scanning as the gold standard. Then, the apical portions of the roots were imaged with spectral domain OCT (SD-OCT) and swept-source OCT systems, and the resulting images were blindly evaluated by 3 independent examiners to detect microcracks. The diagnostic performance of each OCT device was calculated, and statistical analysis was performed. Based on the micro-CT images, 12 (60%) roots presented dentinal microcracks in the apical region. The images generated by the OCT systems were able to show microcrack lines at the same location as the corresponding micro-CT cross sections. Although the diagnostic performance of the SD-OCT device was superior, there were no statistically significant differences between the 2 OCT devices (P > .05). Interexaminer agreement was substantial to almost perfect for the SD-OCT system and moderate to almost perfect for the swept-source OCT system, whereas intraexaminer agreement was substantial to almost perfect for both OCT devices. The detection ability verified for both OCT systems renders them promising tools for the diagnosis of apical microcracks. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Kianbakht, Saeed; Khalighi-Sigaroodi, Farahnaz; Dabaghian, Fataneh Hashem
2013-01-01
Advanced type 2 diabetes mellitus (T2DM) needing insulin therapy is common. Most conventional anti-hyperglycemic drugs have limited efficacies and significant side effects, so that better anti-hyperglycemic agents are needed. Urtica dioica L. (nettle) leaves have insulin secretagogue, PPARgamma agonistic, and alpha-glucosidase inhibitory effects. Moreover, nettle leaves are used in traditional medicine as an anti-hyperglycemic agent to treat diabetes mellitus. Thus, efficacy and safety of nettle in the treatment of patients with advanced type 2 diabetes mellitus needing insulin were studied. In this randomized double-blind placebo-controlled clinical trial, we evaluated the effects of taking nettle leaf extract (one 500 mg capsule every 8 hours for 3 months) combined with the conventional oral anti-hyperglycemic drugs on the blood levels of fasting glucose, postprandial glucose, glycosylated hemoglobin (HbA1c), creatinine and liver enzymes SGOT and SGPT, and systolic and diastolic blood pressures in 46 patients and compared with the placebo group (n = 46). At the endpoint, the extract lowered the blood levels of fasting glucose, 2 hours postprandial glucose, and HbA1c significantly (p < 0.001, p = 0.009, and p = 0.006, respectively) without any significant effects on the other parameters (p > 0.05) compared with placebo. Nettle may safely improve glycemic control in type 2 diabetic patients needing insulin therapy.
Bousquet, J; Maasch, H J; Hejjaoui, A; Skassa-Brociek, W; Wahl, R; Dhivert, H; Michel, F B
1989-10-01
Specific immunotherapy with unmodified formalinized allergoids is effective in grass-pollen allergy, but systemic reactions have been observed. A high-molecular-weight formalinized allergoid (HMW-GOID) was fractionated by gel filtration, retaining molecules of greater than 85,000 daltons in the expectation of improving safety without sacrificing efficacy. HMW-GOID and unfractionated allergoid (GOID) had a similar allergenic activity assessed by RAST inhibition, but the HMW-GOID preparation was 65 times less reactive when it was tested by skin prick test than the GOID preparation. A double-blind, placebo-controlled study was carried out in grass pollen-allergic patients with placebo (14 patients), GOID (15 patients), and HMW-GOID (13 patients). An additional group of 18 patients was treated by a rush schedule with a standardized orchard grass-pollen extract. A similar mean cumulative dose was administered with both allergoids. The fractionated allergoid only elicited minor systemic reactions similar to reactions elicited by placebo, whereas 20% of patients treated by GOID and 5.5% of patients receiving the standardized extract had a severe systemic reaction. For rhinitis, conjunctivitis, and asthma, the HMW-GOID and the standardized extract had a similar efficacy, significantly greater than placebo. GOID was less effective than the other two active treatments but was significantly more effective than placebo treatment for asthma and conjunctivitis.
Udani, Jay K.; George, Annie A.; Musthapa, Mufiza; Pakdaman, Michael N.; Abas, Azreena
2014-01-01
Background. Physta is a proprietary product containing a freeze-dried water extract of Eurycoma longifolia (tongkat ali), which is traditionally used as an energy enhancer and aphrodisiac. We aim to evaluate a 300 mg combination of Physta and Polygonum minus, an antioxidant, with regard to sexual performance and well-being in men. Methods. Men that aged 40–65 years were screened for this 12-week randomized, double-blind, placebo-controlled, parallel-group study. Outcome measures included validated questionnaires that aimed to evaluate erectile function, satisfaction with intervention, sexual intercourse performance, erectile hardness, mood, and overall quality of life. Results. 12 subjects in the active group and 14 in the placebo group completed the study. Significant improvements were noted in scores for the Sexual Intercourse Attempt diary, Erection Hardness Scale, Sexual Health Inventory of Men, and Aging Male Symptom scale (P < 0.05 for all). Three adverse events were reported in the active group and four in the placebo group, none of which were attributed to study product. Laboratory evaluations, including liver and kidney function testing, showed no clinically significant abnormality. Conclusion. Supplementation for twelve weeks with Polygonum minus and the proprietary Eurycoma longifolia extract, Physta, was well tolerated and more effective than placebo in enhancing sexual performance in healthy volunteers. PMID:24550993
Udani, Jay K; George, Annie A; Musthapa, Mufiza; Pakdaman, Michael N; Abas, Azreena
2014-01-01
Background. Physta is a proprietary product containing a freeze-dried water extract of Eurycoma longifolia (tongkat ali), which is traditionally used as an energy enhancer and aphrodisiac. We aim to evaluate a 300 mg combination of Physta and Polygonum minus, an antioxidant, with regard to sexual performance and well-being in men. Methods. Men that aged 40-65 years were screened for this 12-week randomized, double-blind, placebo-controlled, parallel-group study. Outcome measures included validated questionnaires that aimed to evaluate erectile function, satisfaction with intervention, sexual intercourse performance, erectile hardness, mood, and overall quality of life. Results. 12 subjects in the active group and 14 in the placebo group completed the study. Significant improvements were noted in scores for the Sexual Intercourse Attempt diary, Erection Hardness Scale, Sexual Health Inventory of Men, and Aging Male Symptom scale (P < 0.05 for all). Three adverse events were reported in the active group and four in the placebo group, none of which were attributed to study product. Laboratory evaluations, including liver and kidney function testing, showed no clinically significant abnormality. Conclusion. Supplementation for twelve weeks with Polygonum minus and the proprietary Eurycoma longifolia extract, Physta, was well tolerated and more effective than placebo in enhancing sexual performance in healthy volunteers.
Gallien, Philippe; Amarenco, Gérard; Benoit, Nicolas; Bonniaud, Véronique; Donzé, Cécile; Kerdraon, Jacques; de Seze, Marianne; Denys, Pierre; Renault, Alain; Naudet, Florian; Reymann, Jean Michel
2014-08-01
Our aim was to assess the usefulness of cranberry extract in multiple sclerosis (MS) patients suffering from urinary disorders. In total, 171 adult MS outpatients with urinary disorders presenting at eight centers were randomized (stratification according to center and use of clean intermittent self-catheterization) to cranberry versus placebo in a 1-year, prospective, double-blind study that was analyzed using a sequential method on an intent-to-treat basis. An independent monitoring board analyzed the results of the analyses each time 40 patients were assessed on the main endpoint. Cranberry extract (36 mg proanthocyanidins per day) or a matching placebo was taken by participants twice daily for 1 year. The primary endpoint was the time to first symptomatic urinary tract infection (UTI), subject to validation by a validation committee. The second sequential analyses allowed us to accept the null hypothesis (no difference between cranberry and placebo). There was no difference in time to first symptomatic UTI distribution across 1 year, with an estimated hazard ratio of 0.99, 95% CI [0.61, 1.60] (p = 0.97). Secondary endpoints and tolerance did not differ between groups. Taking cranberry extract versus placebo twice a day did not prevent UTI occurrence in MS patients with urinary disorders. Trial Registration NCT00280592. © The Author(s) 2014.
Exploring medication use by blind patients in Saudi Arabia
Kentab, Basma Y.; Al-Rowiali, Kholuod Z.; Al-Harbi, Rehab A.; Al-Shammari, Nouf H.; Balhareth, Wiam M.; Al-Yazeed, Huda F.
2014-01-01
Objective To explore the characteristics of medication use and challenges experienced by the blind patients. Methods This cross-sectional descriptive study included blind persons living in Saudi Arabia who were at least 18 years of age. Participants were recruited through a number of nongovernmental blind associations (in the central, western, eastern regions), universities, social networks, and specialized websites for the blind. A questionnaire was designed and administered via face-to-face meetings with participants and made available online through Google Docs. Results There were a total of 121 respondents of which 26 were excluded based on their ability to visually identify their medications or being <18 years old. The majority of the respondents were 18–29 years old (68%), 49% were male and 51% were female. Around 57% had a college degree while 27% had a high school degree. Diagnosis with a chronic disease was reported by 71 participants (79%, 5 missing). The most common diseases were diabetes and asthma (22%) followed by hypertension (17%). Most blind patients (75%) believed that physicians were the most reliable source of medication information. The medication information and services provided by pharmacists were viewed as inadequate by 46%. The most common challenges encountered by blind patients were linked to drug identification (75%), dose recognition (82%), and identification of expiration date (92%). A large number of patients had to rely on persons with normal vision for dispensing and administering the medications. Conclusions Pharmacists can no longer ignore the medication use problems encountered by the blind people. This study may serve as an initial step for planning improvements in pharmaceutical services provided to blind patients. The government, pharmaceutical companies and pharmacists must work in collaboration to address the special needs of the blind. PMID:25685049
Limburg, Hans; Keunen, Jan E E
2009-01-01
To estimate the magnitude and causes of blindness and low vision in The Netherlands from 2000 to 2020. Recent population-based blindness surveys in established market economies were reviewed. Age and gender specific prevalence and causes of blindness and low vision were extracted and calculated for six population subgroups in The Netherlands. A mathematical model was developed to relate the epidemiologic data with demographic data for each subgroup for each year between 2000 and 2020. In 2008 an estimated 311,000 people are visually impaired in The Netherlands: 77,000 are blind and 234,000 have low vision. With the current intervention the number may increase by 18% to 367,000 in 2020. Visual impairment is most prevalent among residents of nursing homes and care institutions for the elderly, intellectually disabled persons and people aged 50+ living independently. Of all people with visual impairment 31% is male (97,000) and 69% female (214,000). More than half of all visual impairment (56%; 174,000 persons) is avoidable. A variation of around 20% might be applied to the numbers in these estimates. The aim of VISION 2020: The Right to Sight to reduce avoidable visual impairment is also relevant for developed countries like The Netherlands. Vision screening and awareness campaigns focusing on the identified risk groups can reduce avoidable blindness considerably. Regular updates of the model will ensure that the prognoses remain valid and relevant. With appropriate demographic data, the model can also be used in other established market economies.
NASA Astrophysics Data System (ADS)
Wünderlich, D.; Mochalskyy, S.; Montellano, I. M.; Revel, A.
2018-05-01
Particle-in-cell (PIC) codes are used since the early 1960s for calculating self-consistently the motion of charged particles in plasmas, taking into account external electric and magnetic fields as well as the fields created by the particles itself. Due to the used very small time steps (in the order of the inverse plasma frequency) and mesh size, the computational requirements can be very high and they drastically increase with increasing plasma density and size of the calculation domain. Thus, usually small computational domains and/or reduced dimensionality are used. In the last years, the available central processing unit (CPU) power strongly increased. Together with a massive parallelization of the codes, it is now possible to describe in 3D the extraction of charged particles from a plasma, using calculation domains with an edge length of several centimeters, consisting of one extraction aperture, the plasma in direct vicinity of the aperture, and a part of the extraction system. Large negative hydrogen or deuterium ion sources are essential parts of the neutral beam injection (NBI) system in future fusion devices like the international fusion experiment ITER and the demonstration reactor (DEMO). For ITER NBI RF driven sources with a source area of 0.9 × 1.9 m2 and 1280 extraction apertures will be used. The extraction of negative ions is accompanied by the co-extraction of electrons which are deflected onto an electron dump. Typically, the maximum negative extracted ion current is limited by the amount and the temporal instability of the co-extracted electrons, especially for operation in deuterium. Different PIC codes are available for the extraction region of large driven negative ion sources for fusion. Additionally, some effort is ongoing in developing codes that describe in a simplified manner (coarser mesh or reduced dimensionality) the plasma of the whole ion source. The presentation first gives a brief overview of the current status of the ion source development for ITER NBI and of the PIC method. Different PIC codes for the extraction region are introduced as well as the coupling to codes describing the whole source (PIC codes or fluid codes). Presented and discussed are different physical and numerical aspects of applying PIC codes to negative hydrogen ion sources for fusion as well as selected code results. The main focus of future calculations will be the meniscus formation and identifying measures for reducing the co-extracted electrons, in particular for deuterium operation. The recent results of the 3D PIC code ONIX (calculation domain: one extraction aperture and its vicinity) for the ITER prototype source (1/8 size of the ITER NBI source) are presented.
Cortical plasticity associated with Braille learning.
Hamilton, R H; Pascual-Leone, A
1998-05-01
Blind subjects who learn to read Braille must acquire the ability to extract spatial information from subtle tactile stimuli. In order to accomplish this, neuroplastic changes appear to take place. During Braille learning, the sensorimotor cortical area devoted to the representation of the reading finger enlarges. This enlargement follows a two-step process that can be demonstrated with transcranial magnetic stimulation mapping and suggests initial unmasking of existing connections and eventual establishment of more stable structural changes. In addition, Braille learning appears to be associated with the recruitment of parts of the occipital, formerly `visual', cortex (V1 and V2) for tactile information processing. In blind, proficient Braille readers, the occipital cortex can be shown not only to be associated with tactile Braille reading but also to be critical for reading accuracy. Recent studies suggest the possibility of applying non-invasive neurophysiological techniques to guide and improve functional outcomes of these plastic changes. Such interventions might provide a means of accelerating functional adjustment to blindness.
Advanced Optimal Extraction for the Spitzer/IRS
NASA Astrophysics Data System (ADS)
Lebouteiller, V.; Bernard-Salas, J.; Sloan, G. C.; Barry, D. J.
2010-02-01
We present new advances in the spectral extraction of pointlike sources adapted to the Infrared Spectrograph (IRS) on board the Spitzer Space Telescope. For the first time, we created a supersampled point-spread function of the low-resolution modules. We describe how to use the point-spread function to perform optimal extraction of a single source and of multiple sources within the slit. We also examine the case of the optimal extraction of one or several sources with a complex background. The new algorithms are gathered in a plug-in called AdOpt which is part of the SMART data analysis software.
41 CFR 51-1.2 - Mandatory source priorities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Mandatory source priorities. 51-1.2 Section 51-1.2 Public Contracts and Property Management Other Provisions Relating to Public Contracts COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED 1-GENERAL § 51-1.2...
Code of Federal Regulations, 2010 CFR
2010-04-01
... SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY INSURANCE (1950- ) Determining Disability and Blindness Standards for the Type of Referral and for Report Content § 404.1519j Objections to the... we will consider include: The presence of a language barrier, the medical source's office location (e...
Johnson, Jeremy R; Burnell-Nugent, Mary; Lossignol, Dominique; Ganae-Motan, Elena Doina; Potts, Richard; Fallon, Marie T
2010-02-01
This study compared the efficacy of a tetrahydrocannabinol:cannabidiol (THC:CBD) extract, a nonopioid analgesic endocannabinoid system modulator, and a THC extract, with placebo, in relieving pain in patients with advanced cancer. In total, 177 patients with cancer pain, who experienced inadequate analgesia despite chronic opioid dosing, entered a two-week, multicenter, double-blind, randomized, placebo-controlled, parallel-group trial. Patients were randomized to THC:CBD extract (n = 60), THC extract (n = 58), or placebo (n = 59). The primary analysis of change from baseline in mean pain Numerical Rating Scale (NRS) score was statistically significantly in favor of THC:CBD compared with placebo (improvement of -1.37 vs. -0.69), whereas the THC group showed a nonsignificant change (-1.01 vs. -0.69). Twice as many patients taking THC:CBD showed a reduction of more than 30% from baseline pain NRS score when compared with placebo (23 [43%] vs. 12 [21%]). The associated odds ratio was statistically significant, whereas the number of THC group responders was similar to placebo (12 [23%] vs. 12 [21%]) and did not reach statistical significance. There was no change from baseline in median dose of opioid background medication or mean number of doses of breakthrough medication across treatment groups. No significant group differences were found in the NRS sleep quality or nausea scores or the pain control assessment. However, the results from the European Organisation for Research and Treatment of Cancer Quality of Life Cancer Questionnaire showed a worsening in nausea and vomiting with THC:CBD compared with placebo (P = 0.02), whereas THC had no difference (P = 1.0). Most drug-related adverse events were mild/moderate in severity. This study shows that THC:CBD extract is efficacious for relief of pain in patients with advanced cancer pain not fully relieved by strong opioids. Copyright 2010 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
Clinical governance breakdown: Australian cases of wilful blindness and whistleblowing.
Cleary, Sonja; Duke, Maxine
2017-01-01
After their attempts to have patient safety concerns addressed internally were ignored by wilfully blind managers, nurses from Bundaberg Base Hospital and Macarthur Health Service felt compelled to 'blow the whistle'. Wilful blindness is the human desire to prefer ignorance to knowledge; the responsibility to be informed is shirked. To provide an account of instances of wilful blindness identified in two high-profile cases of nurse whistleblowing in Australia. Critical case study methodology using Fay's Critical Social Theory to examine, analyse and interpret existing data generated by the Commissions of Inquiry held into Bundaberg Base Hospital and Macarthur Health Service patient safety breaches. All data was publicly available and assessed according to the requirements of unobtrusive research methods and secondary data analysis. Ethical considerations: Data collection for the case studies relied entirely on publicly available documentary sources recounting and detailing past events. Data from both cases reveal managers demonstrating wilful blindness towards patient safety concerns. Concerns were unaddressed; nurses, instead, experienced retaliatory responses leading to a 'social crisis' in the organisation and to whistleblowing. Managers tasked with clinical governance must be aware of mechanisms with the potential to blind them. The human tendency to favour positive news and avoid conflict is powerful. Understanding wilful blindness can assist managers' awareness of the competing emotions occurring in response to ethical challenges, such as whistleblowing.
USDA-ARS?s Scientific Manuscript database
During a survey of Pennsylvania fruit tree orchards in 2013-2015, some apple trees were found to exhibit abnormally small fruits, clumps of small leaves, blind wood, or premature reddening and curling of leaves. DNA was extracted from symptomatic leaves collected from three apple trees, and the DN...
McKenzie, Kirsten; Mitchell, Rebecca; Scott, Deborah Anne; Harrison, James Edward; McClure, Roderick John
2009-08-01
To examine the reliability of work-related activity coding for injury-related hospitalisations in Australia. A random sample of 4,373 injury-related hospital separations from 1 July 2002 to 30 June 2004 were obtained from a stratified random sample of 50 hospitals across four states in Australia. From this sample, cases were identified as work-related if they contained an ICD-10-AM work-related activity code (U73) allocated by either: (i) the original coder; (ii) an independent auditor, blinded to the original code; or (iii) a research assistant, blinded to both the original and auditor codes, who reviewed narrative text extracted from the medical record. The concordance of activity coding and number of cases identified as work-related using each method were compared. Of the 4,373 cases sampled, 318 cases were identified as being work-related using any of the three methods for identification. The original coder identified 217 and the auditor identified 266 work-related cases (68.2% and 83.6% of the total cases identified, respectively). Around 10% of cases were only identified through the text description review. The original coder and auditor agreed on the assignment of work-relatedness for 68.9% of cases. The best estimates of the frequency of hospital admissions for occupational injury underestimate the burden by around 32%. This is a substantial underestimate that has major implications for public policy, and highlights the need for further work on improving the quality and completeness of routine, administrative data sources for a more complete identification of work-related injuries.
A matched filter approach for blind joint detection of galaxy clusters in X-ray and SZ surveys
NASA Astrophysics Data System (ADS)
Tarrío, P.; Melin, J.-B.; Arnaud, M.
2018-06-01
The combination of X-ray and Sunyaev-Zeldovich (SZ) observations can potentially improve the cluster detection efficiency, when compared to using only one of these probes, since both probe the same medium, the hot ionized gas of the intra-cluster medium. We present a method based on matched multifrequency filters (MMF) for detecting galaxy clusters from SZ and X-ray surveys. This method builds on a previously proposed joint X-ray-SZ extraction method and allows the blind detection of clusters, that is finding new clusters without knowing their position, size, or redshift, by searching on SZ and X-ray maps simultaneously. The proposed method is tested using data from the ROSAT all-sky survey and from the Planck survey. The evaluation is done by comparison with existing cluster catalogues in the area of the sky covered by the deep SPT survey. Thanks to the addition of the X-ray information, the joint detection method is able to achieve simultaneously better purity, better detection efficiency, and better position accuracy than its predecessor Planck MMF, which is based on SZ maps alone. For a purity of 85%, the X-ray-SZ method detects 141 confirmed clusters in the SPT region; to detect the same number of confirmed clusters with Planck MMF, we would need to decrease its purity to 70%. We provide a catalogue of 225 sources selected by the proposed method in the SPT footprint, with masses ranging between 0.7 and 14.5 ×1014 M⊙ and redshifts between 0.01 and 1.2.
Community rehabilitation of disabled with a focus on blind persons: Indian perspective
Jose, R; Sachdeva, Sandeep
2010-01-01
India, the largest democratic country in the world, is marching ahead strongly on the growth and developmental front and is poised to be the leader in the market economy. This role creates and increases far greater responsibilities on us in ensuring that the benefit of the developmental cycle reaches each and every citizen of this country, including the able and the disabled ones. It has been enshrined in the Constitution of India to ensure equality, freedom, justice, and dignity of all individuals and implicitly mandates an inclusive society. With increase in consideration of quality parameters in all spheres of life including availability, access, and provision of comprehensive services to the disabled, it is pertinent to have a look on the contribution of government in keeping the aspiration and commitment towards common people. The article attempts to review the concept of rehabilitation for the disabled keeping a focus on the blind person, and list out the activities, programs/schemes, institutional structure and initiatives taken by the Government of India (GOI) for the same and the incentives/benefits extended to blind persons. The article concludes by reiterating the importance of individual need assessment and mentioning new initiatives proposed on Low Vision services in the approved 11th plan under National Programme for Control of Blindness (NPCB). The source of information has been annual reports, notification and the approved 11th five-year plan of GOI, articles published with key words like rehabilitation, disability, assistive devices, low vision aids, and/or blind person through the mode of Internet. Annexure provides a list of selected institutions in the country offering Low Vision services compiled from various sources through personal communication and an approved list of training institutes under NPCB, GOI offering Low Vision training. PMID:20195037
Community rehabilitation of disabled with a focus on blind persons: Indian perspective.
Jose, R; Sachdeva, Sandeep
2010-01-01
India, the largest democratic country in the world, is marching ahead strongly on the growth and developmental front and is poised to be the leader in the market economy. This role creates and increases far greater responsibilities on us in ensuring that the benefit of the developmental cycle reaches each and every citizen of this country, including the able and the disabled ones. It has been enshrined in the Constitution of India to ensure equality, freedom, justice, and dignity of all individuals and implicitly mandates an inclusive society. With increase in consideration of quality parameters in all spheres of life including availability, access, and provision of comprehensive services to the disabled, it is pertinent to have a look on the contribution of government in keeping the aspiration and commitment towards common people. The article attempts to review the concept of rehabilitation for the disabled keeping a focus on the blind person, and list out the activities, programs/schemes, institutional structure and initiatives taken by the Government of India (GOI) for the same and the incentives/benefits extended to blind persons. The article concludes by reiterating the importance of individual need assessment and mentioning new initiatives proposed on Low Vision services in the approved 11th plan under National Programme for Control of Blindness (NPCB). The source of information has been annual reports, notification and the approved 11th five-year plan of GOI, articles published with key words like rehabilitation, disability, assistive devices, low vision aids, and/or blind person through the mode of Internet. Annexure provides a list of selected institutions in the country offering Low Vision services compiled from various sources through personal communication and an approved list of training institutes under NPCB, GOI offering Low Vision training.
Comparison of Protein Extracts from Various Unicellular Green Sources.
Teuling, Emma; Wierenga, Peter A; Schrama, Johan W; Gruppen, Harry
2017-09-13
Photosynthetic unicellular organisms are considered as promising alternative protein sources. The aim of this study is to understand the extent to which these green sources differ with respect to their gross composition and how these differences affect the final protein isolate. Using mild isolation techniques, proteins were extracted and isolated from four different unicellular sources (Arthrospira (spirulina) maxima, Nannochloropsis gaditana, Tetraselmis impellucida, and Scenedesmus dimorphus). Despite differences in protein contents of the sources (27-62% w/w) and in protein extractability (17-74% w/w), final protein isolates were obtained that had similar protein contents (62-77% w/w) and protein yields (3-9% w/w). Protein solubility as a function of pH was different between the sources and in ionic strength dependency, especially at pH < 4.0. Overall, the characterization and extraction protocol used allows a relatively fast and well-described isolation of purified proteins from novel protein sources.
Comparison of Protein Extracts from Various Unicellular Green Sources
2017-01-01
Photosynthetic unicellular organisms are considered as promising alternative protein sources. The aim of this study is to understand the extent to which these green sources differ with respect to their gross composition and how these differences affect the final protein isolate. Using mild isolation techniques, proteins were extracted and isolated from four different unicellular sources (Arthrospira (spirulina) maxima, Nannochloropsis gaditana, Tetraselmis impellucida, and Scenedesmus dimorphus). Despite differences in protein contents of the sources (27–62% w/w) and in protein extractability (17–74% w/w), final protein isolates were obtained that had similar protein contents (62–77% w/w) and protein yields (3–9% w/w). Protein solubility as a function of pH was different between the sources and in ionic strength dependency, especially at pH < 4.0. Overall, the characterization and extraction protocol used allows a relatively fast and well-described isolation of purified proteins from novel protein sources. PMID:28701042
Current progress in multiple-image blind demixing algorithms
NASA Astrophysics Data System (ADS)
Szu, Harold H.
2000-06-01
Imagery edges occur naturally in human visual systems as a consequence of redundancy reduction towards `sparse and orthogonality feature maps,' which have been recently derived from the maximum entropy information-theoretical first principle of artificial neural networks. After a brief match review of such an Independent Component Analysis or Blind Source Separation of edge maps, we explore the de- mixing condition for more than two imagery objects recognizable by an intelligent pair of cameras with memory in a time-multiplex fashion.
Lavigne, Claire; Durand, Gérard; Roblin, Antoine
2009-04-20
In the atmosphere pointlike sources are surrounded by an aureole due to molecular and aerosol scattering. UV phase functions of haze droplets have a very important forward peak that limits signal angular spreading in relation to the clear atmosphere case where Rayleigh scattering predominates. This specific property can be exploited using solar blind UV source detection as an aircraft landing aid under foggy conditions. Two methods have been used to compute UV light propagation, based on the Monte Carlo technique and a semi-empirical approach. Results obtained after addition of three types of sensor and UV runway light models show that an important improvement in landing conditions during foggy weather could be achieved by use of a solar blind UV intensified CCD camera with two stages of microchannel plates.
Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang
2007-01-01
We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic (EOG) artifacts into individual components. An implementation of the selected BSS/ICA method with SVMs trained to classify EMG and EOG artifacts, which enables the usage of the method as a filter in measurements with online feedback, is described. This filter is evaluated on three BCI datasets as a proof-of-concept of the method. PMID:18288259
Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang
2007-01-01
We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic (EOG) artifacts into individual components. An implementation of the selected BSS/ICA method with SVMs trained to classify EMG and EOG artifacts, which enables the usage of the method as a filter in measurements with online feedback, is described. This filter is evaluated on three BCI datasets as a proof-of-concept of the method.
NASA Astrophysics Data System (ADS)
Strong, Anita A.; Stimpson, Donald I.; Bartholomew, Dwight U.; Jenkins, Thomas F.; Elkind, Jerome L.
1999-08-01
An antibody-based competition assay has been developed using a surface plasmon resonance (SPR) sensor platform for the detection of trinitrotoluene (TNT) in soil extract solutions. The objective of this work is to develop a sensor-based assay technology to use in the field for real- time detection of land mines. This immunoassay combines very simple bio-film attachment procedures and a low-cost SPR sensor design to detect TNT in soil extracts. The active bio-surface is a coating of bovine serum albumin that has been decorated with trinitrobenzene groups. A blind study on extracts from a large soil matrix was recently performed and result from this study will be presented. Potential interferant studied included 2,4-dinitrophenol, 2,4- dinitrotoluene, ammonium nitrate, and 2,4- dichlorophenoxyacetic acid. Cross-reactivity with dinitrotoluene will be discussed. Also, plans to reach sensitivity levels of 1ppb TNT in soil will be described.
An Unsupervised Approach for Extraction of Blood Vessels from Fundus Images.
Dash, Jyotiprava; Bhoi, Nilamani
2018-04-26
Pathological disorders may happen due to small changes in retinal blood vessels which may later turn into blindness. Hence, the accurate segmentation of blood vessels is becoming a challenging task for pathological analysis. This paper offers an unsupervised recursive method for extraction of blood vessels from ophthalmoscope images. First, a vessel-enhanced image is generated with the help of gamma correction and contrast-limited adaptive histogram equalization (CLAHE). Next, the vessels are extracted iteratively by applying an adaptive thresholding technique. At last, a final vessel segmented image is produced by applying a morphological cleaning operation. Evaluations are accompanied on the publicly available digital retinal images for vessel extraction (DRIVE) and Child Heart And Health Study in England (CHASE_DB1) databases using nine different measurements. The proposed method achieves average accuracies of 0.957 and 0.952 on DRIVE and CHASE_DB1 databases respectively.
Berry, Robert J.; Hao, Ling; Li, Zhu; Maneval, David; Yang, Thomas P.; Rasmussen, Sonja A.; Yang, Quanhe; Zhu, Jiang-Hui; Hu, Dale J.; Bailey, Lynn B.
2011-01-01
Folate is a source of one-carbons necessary for DNA methylation, a critical epigenetic modification necessary for genomic structure and function. The use of supplemental folic acid is widespread however; the potential influence on DNA methylation is unclear. We measured global DNA methylation using DNA extracted from samples from a population-based, double-blind randomized trial of folic acid supplementation (100, 400, 4000 µg per day) taken for 6 months; including a 3 month post-supplementation sample. We observed no changes in global DNA methylation in response to up to 4,000 µg/day for 6 months supplementation in DNA extracted from uncoagulated blood (approximates circulating blood). However, when DNA methylation was determined in coagulated samples from the same individuals at the same time, significant time, dose, and MTHFR genotype-dependent changes were observed. The baseline level of DNA methylation was the same for uncoagulated and coagulated samples; marked differences between sample types were observed only after intervention. In DNA from coagulated blood, DNA methylation decreased (−14%; P<0.001) after 1 month of supplementation and 3 months after supplement withdrawal, methylation decreased an additional 23% (P<0.001) with significant variation among individuals (max+17%; min-94%). Decreases in methylation of ≥25% (vs. <25%) after discontinuation of supplementation were strongly associated with genotype: MTHFR CC vs. TT (adjusted odds ratio [aOR] 12.9, 95%CI 6.4, 26.0). The unexpected difference in DNA methylation between DNA extracted from coagulated and uncoagulated samples in response to folic acid supplementation is an important finding for evaluating use of folic acid and investigating the potential effects of folic acid supplementation on coagulation. PMID:22163281
Comparison of auditory stream segregation in sighted and early blind individuals.
Boroujeni, Fatemeh Moghadasi; Heidari, Fatemeh; Rouzbahani, Masoumeh; Kamali, Mohammad
2017-01-18
An important characteristic of the auditory system is the capacity to analyze complex sounds and make decisions on the source of the constituent parts of these sounds. Blind individuals compensate for the lack of visual information by an increase input from other sensory modalities, including increased auditory information. The purpose of the current study was to compare the fission boundary (FB) threshold of sighted and early blind individuals through spectral aspects using a psychoacoustic auditory stream segregation (ASS) test. This study was conducted on 16 sighted and 16 early blind adult individuals. The applied stimuli were presented sequentially as the pure tones A and B and as a triplet ABA-ABA pattern at the intensity of 40dBSL. The A tone frequency was selected as the basis at values of 500, 1000, and 2000Hz. The B tone was presented with the difference of a 4-100% above the basis tone frequency. Blind individuals had significantly lower FB thresholds than sighted people. FB was independent of the frequency of the tone A when expressed as the difference in the number of equivalent rectangular bandwidths (ERBs). Early blindness may increase perceptual separation of the acoustic stimuli to form accurate representations of the world. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
[Montesquieu visually impaired, then blind (January 1689- February 1755)].
Battin, Jacques
2014-01-01
The correspondence of Montesquieu published by the Oxford Foundation informs about visual disorders of the founder of the socio-political science. The examination of his bust's face done by J.B. Lemoyne reveals a divergent squint of the left eye; the one with which he fold that he only could see big objects. This amblyopia was a premature and prolonged embarrassment. During the last ten years of his life, from 1748, date of publication of the Esprit des lois up to his death in 1755 he was blind because of the cataract of the other eye. He has not able to bust in surgery, while the French surgeon Jacques Daviel already proceeded to the extraction of the lens as we do it nowadays.
O'Shea, Deirdre M; Fieo, Robert A
2015-07-01
Previous research has shown that aging increases susceptibility to inattentional blindness (Graham and Burke, Psychol Aging 26:162, 2011) as well as individual differences in cognitive ability related to working memory and executive functions in separate studies. Therefore, the present study was conducted in an attempt to bridge a gap that involved investigating 'age-sensitive' cognitive abilities that may predict inattentional blindness in a sample of older adults. We investigated whether individual differences in general fluid intelligence and speed of processing would predict inattentional blindness in our sample of older adults. Thirty-six healthy older adults took part in the study. Using the inattentional blindness paradigm developed by Most et al. (Psychol Rev 112:217, 2005), we investigated whether rates of inattentional blindness could be predicted by participant's performance on the Raven's Advanced Progressive Matrices and a choice-reaction time task. A Mann-Whitney U test revealed that a higher score on the Raven's Advanced Progressive Matrices was significantly associated with lower incidences of inattentional blindness. However, a t test revealed that choice-reaction times were not significantly associated with inattentional blindness. Preliminary results from the present study suggest that individual differences in general fluid intelligence are predictive of inattentional blindness in older adults but not speed of processing. Moreover, our findings are consistent with previous studies that have suggested executive attention control may be the source of these individual differences. These findings also highlight the association between attention and general fluid intelligence and how it may impact environmental awareness. Future research would benefit from repeating these analyses in a larger sample and also including a younger comparison group.
Di Paolo, Carolina; Ottermanns, Richard; Keiter, Steffen; Ait-Aissa, Selim; Bluhm, Kerstin; Brack, Werner; Breitholtz, Magnus; Buchinger, Sebastian; Carere, Mario; Chalon, Carole; Cousin, Xavier; Dulio, Valeria; Escher, Beate I; Hamers, Timo; Hilscherová, Klára; Jarque, Sergio; Jonas, Adam; Maillot-Marechal, Emmanuelle; Marneffe, Yves; Nguyen, Mai Thao; Pandard, Pascal; Schifferli, Andrea; Schulze, Tobias; Seidensticker, Sven; Seiler, Thomas-Benjamin; Tang, Janet; van der Oost, Ron; Vermeirssen, Etienne; Zounková, Radka; Zwart, Nick; Hollert, Henner
2016-11-01
Bioassays are particularly useful tools to link the chemical and ecological assessments in water quality monitoring. Different methods cover a broad range of toxicity mechanisms in diverse organisms, and account for risks posed by non-target compounds and mixtures. Many tests are already applied in chemical and waste assessments, and stakeholders from the science-police interface have recommended their integration in regulatory water quality monitoring. Still, there is a need to address bioassay suitability to evaluate water samples containing emerging pollutants, which are a current priority in water quality monitoring. The presented interlaboratory study (ILS) verified whether a battery of miniaturized bioassays, conducted in 11 different laboratories following their own protocols, would produce comparable results when applied to evaluate blinded samples consisting of a pristine water extract spiked with four emerging pollutants as single chemicals or mixtures, i.e. triclosan, acridine, 17α-ethinylestradiol (EE2) and 3-nitrobenzanthrone (3-NBA). Assays evaluated effects on aquatic organisms from three different trophic levels (algae, daphnids, zebrafish embryos) and mechanism-specific effects using in vitro estrogenicity (ER-Luc, YES) and mutagenicity (Ames fluctuation) assays. The test battery presented complementary sensitivity and specificity to evaluate the different blinded water extract spikes. Aquatic organisms differed in terms of sensitivity to triclosan (algae > daphnids > fish) and acridine (fish > daphnids > algae) spikes, confirming the complementary role of the three taxa for water quality assessment. Estrogenicity and mutagenicity assays identified with high precision the respective mechanism-specific effects of spikes even when non-specific toxicity occurred in mixture. For estrogenicity, although differences were observed between assays and models, EE2 spike relative induction EC 50 values were comparable to the literature, and E2/EE2 equivalency factors reliably reflected the sample content. In the Ames, strong revertant induction occurred following 3-NBA spike incubation with the TA98 strain, which was of lower magnitude after metabolic transformation and when compared to TA100. Differences in experimental protocols, model organisms, and data analysis can be sources of variation, indicating that respective harmonized standard procedures should be followed when implementing bioassays in water monitoring. Together with other ongoing activities for the validation of a basic bioassay battery, the present study is an important step towards the implementation of bioanalytical monitoring tools in water quality assessment and monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.
van Poppel, Pleun C. M.; Breedveld, Pauline; Abbink, Evertine J.; Roelofs, Hennie; van Heerde, Waander; Smits, Paul; Lin, Wenzhi; Tan, Aaitje H.; Russel, Frans G.; Donders, Rogier; Tack, Cees J.; Rongen, Gerard A.
2015-01-01
Purpose Danshen is the dried root extract of the plant Salvia Miltiorrhiza and it is used as traditional Chinese medicinal herbal product to prevent and treat atherosclerosis. However, its efficacy has not been thoroughly investigated. This study evaluates the effect of Danshen on hyperlipidemia and hypertension, two well known risk factors for the development of atherosclerosis. Methods This was a randomized, placebo-controlled, double-blind crossover study performed at a tertiary referral center. Participants were recruited by newspaper advertisement and randomized to treatment with Danshen (water-extract of the Salvia Miltiorrhiza root) or placebo for 4 consecutive weeks. There was a wash out period of 4 weeks. Of the 20 analysed participants, 11 received placebo first. Inclusion criteria were: age 40-70 years, hyperlipidemia and hypertension. At the end of each treatment period, plasma lipids were determined (primary outcome), 24 hours ambulant blood pressure measurement (ABPM) was performed, and vasodilator endothelial function was assessed in the forearm. Results LDL cholesterol levels were 3.82±0.14 mmol/l after Danshen and 3.52±0.16 mmol/l after placebo treatment (mean±SE; p<0.05 for treatment effect corrected for baseline). Danshen treatment had no effect on blood pressure (ABPM 138/84 after Danshen and 136/87 after placebo treatment). These results were further substantiated by the observation that Danshen had neither an effect on endothelial function nor on markers of inflammation, oxidative stress, glucose metabolism, hemostasis and blood viscosity. Conclusion Four weeks of treatment with Danshen (water-extract) slightly increased LDL-cholesterol without affecting a wide variety of other risk markers. These observations do not support the use of Danshen to prevent or treat atherosclerosis. Trial Registration ClinicalTrials.gov NCT01563770 PMID:26192328
Code of Federal Regulations, 2010 CFR
2010-04-01
... Disability and Blindness Standards for the Type of Referral and for Report Content § 416.919j Objections to... we will consider include: The presence of a language barrier, the medical source's office location (e... connection with a previous disability determination or decision that was unfavorable to you. If your...
Self-delivered misinformation - Merging the choice blindness and misinformation effect paradigms.
Stille, Lotta; Norin, Emelie; Sikström, Sverker
2017-01-01
Choice blindness is the failure to detect a discrepancy between a choice and its outcome. The misinformation effect occurs when the recollection of an event changes because new, misleading information about the event is received. The purpose of this study was to merge the choice blindness and misinformation effect paradigms, and thus examine whether choice blindness can be created for individuals' recollections of a witnessed event, and whether this will affect their later recollections of the event. Thus, as a way of delivering misinformation the participants ostensibly became their own source of the misleading information. The participants watched a short film and filled out a questionnaire about events shown in the film. Some of their answers were then manipulated using reattachable stickers, which allowed alteration of their original answers. The participants gave justifications for their manipulated choices, and later their recollection of the original event was tested through another questionnaire. Choice blindness was created for a majority of the participants. A majority of the choice blind participants later changed their reported recollection of the event in line with the manipulations, whereas only a small minority of the participants in the control condition changed their recollection. This study provides new information about the misinformation effect, suggesting that this effect also can occur when misinformation is given immediately following presentation of the original stimuli, and about choice blindness and its effects on the recollections of events. The results suggest that memory blindness can be created when people inadvertently supply themselves with misleading information about an event, causing a change in their recollection.
Self-delivered misinformation - Merging the choice blindness and misinformation effect paradigms
Stille, Lotta; Norin, Emelie; Sikström, Sverker
2017-01-01
Choice blindness is the failure to detect a discrepancy between a choice and its outcome. The misinformation effect occurs when the recollection of an event changes because new, misleading information about the event is received. The purpose of this study was to merge the choice blindness and misinformation effect paradigms, and thus examine whether choice blindness can be created for individuals’ recollections of a witnessed event, and whether this will affect their later recollections of the event. Thus, as a way of delivering misinformation the participants ostensibly became their own source of the misleading information. The participants watched a short film and filled out a questionnaire about events shown in the film. Some of their answers were then manipulated using reattachable stickers, which allowed alteration of their original answers. The participants gave justifications for their manipulated choices, and later their recollection of the original event was tested through another questionnaire. Choice blindness was created for a majority of the participants. A majority of the choice blind participants later changed their reported recollection of the event in line with the manipulations, whereas only a small minority of the participants in the control condition changed their recollection. This study provides new information about the misinformation effect, suggesting that this effect also can occur when misinformation is given immediately following presentation of the original stimuli, and about choice blindness and its effects on the recollections of events. The results suggest that memory blindness can be created when people inadvertently supply themselves with misleading information about an event, causing a change in their recollection. PMID:28273151
Cuban Epidemic optic neuropathy (1991-1993) And josé saramago's novel blindness (1995).
Feibel, Robert M; Arch, Jennifer
2018-06-12
This article reviews the history of Cuban Epidemic Optic Neuropathy (1991-1993), which caused visual loss, peripheral neuralgias, and other neurological symptoms in over 50,000 persons, an incidence of almost 0.5% of the entire population. The clinical findings, etiology, and treatment are described. We then relate the Cuban epidemic to the fictional epidemic of contagious blindness depicted by Nobel Laureate José Saramago in his 1995 novel Blindness. This novel describes an unnamed modern city in which all inhabitants, except the ophthalmologist's wife, are affected with a white, not black, blindness. Historical review and literary essay. The sources for the Cuban epidemic were an extensive review of the published literature and personal communications with physicians who treated these patients. Both authors have analyzed the novel and the critical literature about Saramago's writings. Though Saramago uses the epidemic of blindness as an allegory to comment on human weakness and immorality, he may also have known of the actual Cuban epidemic. Saramago was a lifelong member of the Communist party, as well as a friend of Fidel Castro and admirer of the Cuban government. We have no proof that Blindness was influenced by the Cuban epidemic, but we find it plausible. It is valuable to examine the real and fictional epidemics side by side, not least because Saramago's novel depicts the actions of an ophthalmologist during an epidemic of blindness. Ophthalmologists may be interested in a novel that uses the language of eyes, vision, sight, and blindness extensively. Copyright © 2018 Elsevier Inc. All rights reserved.
Do saw palmetto extracts block human alpha1-adrenoceptor subtypes in vivo?
Goepel, M; Dinh, L; Mitchell, A; Schäfers, R F; Rübben, H; Michel, M C
2001-02-15
To test whether saw palmetto extracts, which act as alpha1-adrenoceptor antagonists in vitro, also do so in vivo in man. In a placebo-controlled, double-blind, four-way cross-over study 12 healthy young men were treated with three different saw palmetto extract preparations (320 mg o.d.) for 8 days each. On the last day, before and 2, 4 and 6 hr after drug intake blood pressure and heart rate were determined and blood samples obtained, which were used in an ex vivo radioreceptor assay with cloned human alpha1-adrenoceptor subtypes. Saw palmetto extract treatment did not result in alpha1-adrenoceptor subtype occupancy in the radioreceptor assay. Although the saw palmetto extracts caused minor reductions of supine blood pressure, they did not affect blood pressure during orthostatic stress testing and did not alter heart rate under either condition. Moreover, plasma catecholamines remained largely unaltered. Despite their alpha1-adrenoceptor antagonist effects in vitro, therapeutically used doses of saw palmetto extracts do not cause alpha1-adrenoceptor antagonism in man in vivo. Copyright 2001 Wiley-Liss, Inc.
Karm, Myong-Hwan; Park, Fiona Daye; Kang, Moonkyu; Kim, Hyun Jeong; Kang, Jeong Wan; Kim, Seungoh; Kim, Yong-Deok; Kim, Cheul-Hong; Seo, Kwang-Suk; Kwon, Kyung-Hwan; Kim, Chul-Hwan; Lee, Jung-Woo; Hong, Sung-Woon; Lim, Mi Hyoung; Nam, Seung Kwan; Cho, Jae Min
2017-05-01
The most commonly impacted tooth is the third molar. An impacted third molar can ultimately cause acute pain, infection, tumors, cysts, caries, periodontal disease, and loss of adjacent teeth. Local anesthesia is employed for removing the third molar. This study aimed to evaluate the efficacy and safety of 2% lidocaine with 1:80,000 or 1:200,000 epinephrine for surgical extraction of bilateral impacted mandibular third molars. Sixty-five healthy participants underwent surgical extraction of bilateral impacted mandibular third molars in 2 separate visits while under local anesthesia with 2% lidocaine with different epinephrine concentration (1:80,000 or 1:200,000) in a double-blind, randomized, crossover trial. Visual analog scale pain scores obtained immediately after surgical extraction were primarily evaluated for the 2 groups receiving different epinephrine concentrations. Visual analog scale pain scores were obtained 2, 4, and 6 hours after administering an anesthetic. Onset and duration of analgesia, onset of pain, intraoperative bleeding, operator's and participant's overall satisfaction, drug dosage, and hemodynamic parameters were evaluated for the 2 groups. There were no statistically significant differences between the 2 groups in any measurements except hemodynamic factors (P >.05). Changes in systolic blood pressure and heart rate following anesthetic administration were significantly greater in the group receiving 1:80,000 epinephrine than in that receiving 1:200,000 epinephrine (P ≤.01). The difference in epinephrine concentration between 1:80,000 and 1:200,000 in 2% lidocaine liquid does not affect the medical efficacy of the anesthetic. Furthermore, 2% lidocaine with 1:200,000 epinephrine has better safety with regard to hemodynamic parameters than 2% lidocaine with 1:80,000 epinephrine. Therefore, we suggest using 2% lidocaine with 1:200,000 epinephrine rather than 2% lidocaine with 1:80,000 epinephrine for surgical extraction of impacted mandibular third molars in hemodynamically unstable patients.
Kämmerer, P W; Schneider, D; Palarie, V; Schiegnitz, E; Daubländer, M
2017-01-01
The purpose of this clinical prospective, randomized, double-blind trial was to compare the anesthetic efficacy of 2 % articaine and 4 % articaine in inferior alveolar nerve block anesthesia for extraction of mandibular teeth. In 95 patients, 105 lower molar and premolar teeth were extracted after intraoral inferior alveolar nerve block. In 53 cases, 2 % articaine (group I) and, in 52 cases, 4 % articaine (group II) was administered. The primary objective was to analyze the differences of anesthetic effects between the two groups (complete/sufficient vs. insufficient/none). Furthermore, differences in pulpal anesthesia (onset and depth, examined with pulp vitality tester (min)), as well as in length of soft tissue anesthesia (min), were evaluated. Additionally, the need of a second injection, pain while injecting (numeric rating scale (NRS)), pain during treatment (NRS), pain after treatment (NRS), and other possible complications (excessive pain, bleeding events, prolonged deafness) were analyzed. Anesthesia was sufficient for dental extractions in both groups without significant differences (p = 0.201). The onset of anesthesia did not differ significantly (p = 0.297). A significantly shorter duration of soft tissue anesthesia was seen in group I (2.9 vs. 4 h; p < 0.001). There was no significant difference in the need for a second injection (p = 0.359), in injection pain (p = 0.386), as well as in pain during (p = 0.287) or after treatment (p = 0.121). In both groups, no complications were seen. The local anesthetic effect of the 4 % articaine solution is not significantly better when compared to 2 % articaine. For mandibular tooth extraction, articaine 2 % may be used as alternative as well.
Fedder, Maja D K; Jakobsen, Henrik B; Giversen, Ina; Christensen, Lars P; Parner, Erik T; Fedder, Jens
2014-01-01
Pomegranate fruit (Punica granatum) and galangal (Alpinia galanga) have separately been shown to stimulate spermatogenesis and to increase sperm counts and motility in rodents. Within traditional medicine, pomegranate fruit has long been used to increase fertility, however studies on the effect on spermatogenesis in humans have never been published. With this study we investigated whether oral intake of tablets containing standardised amounts of extract of pomegranate fruit and powder of greater galangal rhizome (Punalpin) would increase the total number of motile spermatozoa. The study was designed as a prospective, randomized, controlled, double-blinded trial. Enrolment was based on the mean total number of motile spermatozoa of two ejaculates. The participants delivered an ejaculate after 4-8 days of tablet intake and two ejaculates just before they stopped taking the tablets. Seventy adult men with a semen quality not meeting the standards for commercial application at Nordic Cryobank, but without azoospermia, were included in the study. Participants were randomized to take tablets containing extract of pomegranate fruit (standardised with respect to punicalagin A+B, punicalin and ellagic acid) and freeze-dried rhizome of greater galangal (standardised with respect to 1'S-1'-acetoxychavicol acetate) or placebo on a daily basis for three months. Sixty-six participants completed the intervention (active treatment: n = 34; placebo: n = 32). After the intervention the total number of motile spermatozoa was increased in participants treated with plant extracts compared with the placebo group (p = 0.026). After three months of active treatment, the average total number of motile sperm increased by 62% (from 23.4 to 37.8 millions), while for the placebo group, the number of motile sperm increased by 20%. Sperm morphology was not affected by the treatment. Our findings may help subfertile men to gain an improved amount of motile ejaculated sperm by taking tablets containing preparations of pomegranate fruit extract and rhizome of greater galangal. ClinicalTrials.gov NCT01357044.
Studies on the Extraction Region of the Type VI RF Driven H- Ion Source
NASA Astrophysics Data System (ADS)
McNeely, P.; Bandyopadhyay, M.; Franzen, P.; Heinemann, B.; Hu, C.; Kraus, W.; Riedl, R.; Speth, E.; Wilhelm, R.
2002-11-01
IPP Garching has spent several years developing a RF driven H- ion source intended to be an alternative to the current ITER (International Thermonuclear Experimental Reactor) reference design ion source. A RF driven source offers a number of advantages to ITER in terms of reduced costs and maintenance requirements. Although the RF driven ion source has shown itself to be competitive with a standard arc filament ion source for positive ions many questions still remain on the physics behind the production of the H- ion beam extracted from the source. With the improvements that have been implemented to the BATMAN (Bavarian Test Machine for Negative Ions) facility over the last two years it is now possible to study both the extracted ion beam and the plasma in the vicinity of the extraction grid in greater detail. This paper will show the effect of changing the extraction and acceleration voltage on both the current and shape of the beam as measured on the calorimeter some 1.5 m downstream from the source. The extraction voltage required to operate in the plasma limit is 3 kV. The perveance optimum for the extraction system was determined to be 2.2 x 10-6 A/V3/2 and occurs at 2.7 kV extraction voltage. The horizontal and vertical beam half widths vary as a function of the extracted ion current and the horizontal half width is generally smaller than the vertical. The effect of reducing the co-extracted electron current via plasma grid biasing on the H- current extractable and the beam profile from the source is shown. It is possible in the case of a silver contaminated plasma to reduce the co-extracted electron current to 20% of the initial value by applying a bias of 12 V. In the case where argon is present in the plasma, biasing is observed to have minimal effect on the beam half width but in a pure hydrogen plasma the beam half width increases as the bias voltage increases. New Langmuir probe studies that have been carried out parallel to the plasma grid (in the vicinity of the peak of the external magnetic filter field) and changes to source parameters as a function of power, and argon addition are reported. The behaviour of the electron density is different when the plasma is argon seeded showing a strong increase with RF power. The plasma potential is decreased by 2 V when argon is added to the plasma. The effect of the presence of unwanted silver sputtered from the Faraday screen by Ar+ ions on both the source performance and the plasma parameters is also presented. The silver dramatically downgraded source performance in terms of current density and produced an early saturation of current with applied RF power. Recently, collaboration was begun with the Technical University of Augsburg to perform spectroscopic measurements on the Type VI ion source. The final results of this analysis are not yet ready but some interesting initial observations on the gas temperature, disassociation degree and impurity ions will be presented.
ERIC Educational Resources Information Center
Hasanzadeh, Elmira; Mohammadi, Mohammad-Reza; Ghanizadeh, Ahmad; Rezazadeh, Shams-Ali; Tabrizi, Mina; Rezaei, Farzin; Akhondzadeh, Shahin
2012-01-01
"Ginkgo biloba" has been reported to affect the neurotransmitter system and to have antioxidant properties that could impact the pathogenesis of Autism Spectrum Disorder. Based on these studies, we decided to assess the effectiveness of "Ginkgo biloba" extract (Ginko T.D., Tolidaru, Iran) as an adjunctive agent to risperidone in the treatment of…
van Veen, Leonieke N; Heron, Michiel; Batstra, Manou; van Haard, Paul M M; de Groot, Hans
2016-06-02
To date, diagnosing food allergies in children still presents a diagnostic dilemma, leading to uncertainty concerning the definite diagnosis of peanut allergy, as well as to the need for strict diets and the potential need for adrenalin auto-injectors. This uncertainty in particular is thought to contribute to a lower quality of life. In the diagnostic process double-blind food challenges are considered the gold standard, but they are time-consuming as well as potentially hazardous. Other diagnostic tests have been extensively studied and among these component-resolved diagnostics appeared to present a promising alternative: Ara h2, a peanut storage protein in previous studies showed to have a significant predictive value. Sixty-two out of 72 children, with suspected peanut allergy were analyzed using serum specific IgE and/or skin prick tests and specific IgE to several components of peanut (Ara h 1, 2, 3, 6, 8, 9). Subsequently, double-blind food challenges were performed. The correlation between the various diagnostic tests and the overall outcome of the double-blind food challenges were studied, in particular the severity of the reaction and the eliciting dose. The double-blind provocation with peanut was positive in 33 children (53 %). There was no relationship between the eliciting dose and the severity of the reaction. A statistically significant relationship was found between the skin prick test, specific IgE directed to peanut, Ara h 1, Ara h 2 or Ara h 6, and the outcome of the food challenge test, in terms of positive or negative (P < .001). However, we did not find any relationship between sensitisation to peanut extract or the different allergen components and the severity of the reaction or the eliciting dose. There was no correlation between IgE directed to Ara h 3, Ara h 8, Ara h 9 and the clinical outcome of the food challenge. This study shows that component-resolved diagnostics is not superior to specific IgE to peanut extract or to skin prick testing. At present, it cannot replace double-blind placebo-controlled food challenges for determination of the eliciting dose or the severity of the peanut allergy in our patient group.
Erfurt, L; Schandry, R; Rubenbauer, S; Braun, U
2014-09-25
The present study investigated the effects of repeated administration of Korodin(®), a combination of camphor and crataegus berry extract, on blood pressure and attentional functioning. This study was conducted based on a randomized, placebo-controlled, double-blind design. 54 persons participated (33 female, 21 male) with a mean age of 24.3 years. Blood pressure and body mass index were in the normal range. Participants received 20 drops of either Korodin(®) or a placebo for four times with interjacent time intervals of about 10 min. Blood pressure was measured sphygmomanometrically before and after each administration. Attentional performance was quantified by using two paper-and-pencil tests, the d2 Test of Attention and Digit Symbol Test. Greater increases in blood pressure occurred after the four Korodin(®) administrations in comparison to the four placebo administrations. The performance in two parameters of d2 Test of Attention was consistently superior after the intake of Korodin(®). The excellent tolerability and safety of Korodin(®), even after a total consumption of 80 drops, was confirmed. Copyright © 2014 Elsevier GmbH. All rights reserved.
Microdrilling of PCB substrate using DPSS 3rd harmonic laser
NASA Astrophysics Data System (ADS)
Kim, J. G.; Chang, Won Seok; Yoon, Kyung Ku; Jeong, Sungho; Shin, Bo Sung; Whang, Kyung Hyun
2003-02-01
Micromachining using the DPSS 3rd Harmonic Laser (355nm) has outstanding advantages as a UV source in comparison with Excimer lasers in various aspects such as maintenance cost, maskless machining, high repetition rate and so on. It also has the greater absorptivity of many materials in contrast to other IR sources. In this paper, the process for micro-drilling of through and blind hope in Cu/PI/Cu substrate with the UV DPSSL and a scanning device is investigated by both experimental and numerical methods. It is known that there is a large gap between the ablation threshold of copper and that of PI. We use the multi path for through hole with high energy density and we use Archimedes spiral path for blind hole with different energy densities to ablate different material. Furthermore, Matlab simulations considering the energy threshold of material is performed to anticipate the ablation shape according to the duplication of pulse, and FEM thermal analysis is used to predict the ablation depth of copper. This study would be widely applicable to various laser micromachining applications including through and blind hole micro-drilling of PCB, and micromachining of semiconductor components, medical parts and printer nozzles amongst others.
Downey, Luke A; Kean, James; Nemeh, Fiona; Lau, Angela; Poll, Alex; Gregory, Rebecca; Murray, Margaret; Rourke, Johanna; Patak, Brigit; Pase, Matthew P; Zangara, Andrea; Lomas, Justine; Scholey, Andrew; Stough, Con
2013-09-01
Standardized extracts of the traditional Ayurvedic medicine Bacopa monnieri (BM) (Brahmi) have been recently shown to have cognitive enhancing effects in chronic administration studies. Pre-clinical work has also identified a number of acute anxiolytic, nootropic, and cardiovascular effects of BM. There has, however, been little research on the acute effects of BM on cognitive function. The current study aimed to assess the acute effects of a specific extract of BM (KeenMind®-CDRI 08) in a double-blind, placebo-controlled study in normal healthy participants who completed a cognitively demanding series of tests. Twenty-four healthy volunteers completed six repetitions of the Cognitive Demand Battery (CDB) after consuming a placebo, 320 mg BM or 640 mg of BM in a cross-over design and provided cardiovascular and mood assessments before and after treatment. Change from baseline scores indicated that the 320 mg dose of BM improved performance at the first, second, and fourth repetition post-dosing on the CDB, and the treatments had no effect upon cardiovascular activity or in attenuating task-induced ratings of stress and fatigue. It was concluded that assessment of an earlier pharmacological window and use of less memory-specific cognitive tests together with more temporally sensitive measures of brain activity may improve our understanding of the acute neurocognitive properties of BM. Copyright © 2012 John Wiley & Sons, Ltd.
Lopatkin, Nikolai; Sivkov, Andrey; Schläfke, Sandra; Funk, Petra; Medvedev, Alexander; Engelmann, Udo
2007-01-01
In an open-label extension of a randomized, double-blind clinical trial, the long-term efficacy and tolerability of a fixed combination of 160 mg Sabal fruit extract WS 1473 and 120 mg Urtica root extract WS 1031 per capsule (PRO 160/120) were investigated in elderly men with moderate or severe lower urinary tract symptoms (LUTS) caused by benign prostatic hyperplasia (BPH). Two hundred and fifty-seven patients were randomly treated with 2 x 1 capsule/day PRO 160/120 or placebo for 24 weeks, followed by a 24-week control period and a 48-week follow-up period in which all patients received PRO 160/120. Efficacy measures included the assessment of LUTS [International Prostate Symptom Score ((I-PSS) self-rating questionnaire] and uroflow and sonographic parameters. Two hundred and nineteen subjects participated in the follow-up. Between baseline and end of observation (week 96) the I-PSS total score was reduced by 53% (P < 0.001), peak and average urinary flow increased by 19% (P < 0.001), and residual urine volume decreased by 44% (P = 0.03). The incidence of adverse events during follow-up was one in 1,181 treatment days; in only one event a causal relationship with intake of PRO 160/120 could not be excluded. Treatment with PRO 160/120 thus provides a clinically relevant benefit over a period of 96 weeks.
Schneider, T; Rübben, H
2004-03-01
Phytotherapy of BPS has a long tradition in Germany; nevertheless, data referring to single phytotherapeutic agents are rare. We therefore performed a randomized, double-blind, placebo-controlled multicenter study for 1 year with Bazoton uno (459 mg dry extract of stinging nettle roots) with 246 patients. The IPSS decreased on average from 18.7+/-0.3 to 13.0+/-0.5 with a statistically significant difference compared to placebo (18.5+/-0.3 to 13.8+/-0.5; p=0.0233). The median Q(max) increased by 3.0+/-0.4 ml/s in comparison to 2.9+/-0.4 ml/s (placebo), thus not statistically significantly different, as well as the median volume of residual urine, which changed from 35.5+/-3.4 ml before therapy to 20.0+/-2.8 ml and from 40.0+/-4.0 ml to 21.0+/-2.9 ml under placebo application. The number of adverse events (29/38) as well as urinary infections etc. (3/10 events) was smaller under Bazoton uno therapy compared to placebo. Treatment with Bazoton uno can therefore be considered a safe therapeutic option for BPS, especially for reducing irritative symptoms and BPS-associated complications due to the postulated antiphlogistic and antiproliferative effects of the stinging nettle extract. A strong increase of Q(max) or reduction of residual urine are not to be expected.
48 CFR 8.700 - Scope of subpart.
Code of Federal Regulations, 2011 CFR
2011-10-01
... REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition From Nonprofit Agencies Employing People Who Are... Purchase from People Who Are Blind or Severely Disabled (41 CFR Chapter 51) which implements the AbilityOne...
Separation of GRACE geoid time-variations using Independent Component Analysis
NASA Astrophysics Data System (ADS)
Frappart, F.; Ramillien, G.; Maisongrande, P.; Bonnet, M.
2009-12-01
Independent Component Analysis (ICA) is a blind separation method based on the simple assumptions of the independence of the sources and the non-Gaussianity of the observations. An approach based on this numerical method is used here to extract hydrological signals over land and oceans from the polluting striping noise due to orbit repetitiveness and present in the GRACE global mass anomalies. We took advantage of the availability of monthly Level-2 solutions from three official providers (i.e., CSR, JPL and GFZ) that can be considered as different observations of the same phenomenon. The efficiency of the methodology is first demonstrated on a synthetic case. Applied to one month of GRACE solutions, it allows to clearly separate the total water storage change from the meridional-oriented spurious gravity signals on the continents but not on the oceans. This technique gives results equivalent as the destriping method for continental water storage for the hydrological patterns with less smoothing. This methodology is then used to filter the complete series of the 2002-2009 GRACE solutions.
Sales, C; Cervera, M I; Gil, R; Portolés, T; Pitarch, E; Beltran, J
2017-02-01
The novel atmospheric pressure chemical ionization (APCI) source has been used in combination with gas chromatography (GC) coupled to hybrid quadrupole time-of-flight (QTOF) mass spectrometry (MS) for determination of volatile components of olive oil, enhancing its potential for classification of olive oil samples according to their quality using a metabolomics-based approach. The full-spectrum acquisition has allowed the detection of volatile organic compounds (VOCs) in olive oil samples, including Extra Virgin, Virgin and Lampante qualities. A dynamic headspace extraction with cartridge solvent elution was applied. The metabolomics strategy consisted of three different steps: a full mass spectral alignment of GC-MS data using MzMine 2.0, a multivariate analysis using Ez-Info and the creation of the statistical model with combinations of responses for molecular fragments. The model was finally validated using blind samples, obtaining an accuracy in oil classification of 70%, taking the official established method, "PANEL TEST", as reference. Copyright © 2016 Elsevier Ltd. All rights reserved.
Improving mental task classification by adding high frequency band information.
Zhang, Li; He, Wei; He, Chuanhong; Wang, Ping
2010-02-01
Features extracted from delta, theta, alpha, beta and gamma bands spanning low frequency range are commonly used to classify scalp-recorded electroencephalogram (EEG) for designing brain-computer interface (BCI) and higher frequencies are often neglected as noise. In this paper, we implemented an experimental validation to demonstrate that high frequency components could provide helpful information for improving the performance of the mental task based BCI. Electromyography (EMG) and electrooculography (EOG) artifacts were removed by using blind source separation (BSS) techniques. Frequency band powers and asymmetry ratios from the high frequency band (40-100 Hz) together with those from the lower frequency bands were used to represent EEG features. Finally, Fisher discriminant analysis (FDA) combining with Mahalanobis distance were used as the classifier. In this study, four types of classifications were performed using EEG signals recorded from four subjects during five mental tasks. We obtained significantly higher classification accuracy by adding the high frequency band features compared to using the low frequency bands alone, which demonstrated that the information in high frequency components from scalp-recorded EEG is valuable for the mental task based BCI.
White, David J.; Congedo, Marco; Ciorciari, Joseph
2014-01-01
A developing literature explores the use of neurofeedback in the treatment of a range of clinical conditions, particularly ADHD and epilepsy, whilst neurofeedback also provides an experimental tool for studying the functional significance of endogenous brain activity. A critical component of any neurofeedback method is the underlying physiological signal which forms the basis for the feedback. While the past decade has seen the emergence of fMRI-based protocols training spatially confined BOLD activity, traditional neurofeedback has utilized a small number of electrode sites on the scalp. As scalp EEG at a given electrode site reflects a linear mixture of activity from multiple brain sources and artifacts, efforts to successfully acquire some level of control over the signal may be confounded by these extraneous sources. Further, in the event of successful training, these traditional neurofeedback methods are likely influencing multiple brain regions and processes. The present work describes the use of source-based signal processing methods in EEG neurofeedback. The feasibility and potential utility of such methods were explored in an experiment training increased theta oscillatory activity in a source derived from Blind Source Separation (BSS) of EEG data obtained during completion of a complex cognitive task (spatial navigation). Learned increases in theta activity were observed in two of the four participants to complete 20 sessions of neurofeedback targeting this individually defined functional brain source. Source-based EEG neurofeedback methods using BSS may offer important advantages over traditional neurofeedback, by targeting the desired physiological signal in a more functionally and spatially specific manner. Having provided preliminary evidence of the feasibility of these methods, future work may study a range of clinically and experimentally relevant brain processes where individual brain sources may be targeted by source-based EEG neurofeedback. PMID:25374520
Relevance of Spectral Cues for Auditory Spatial Processing in the Occipital Cortex of the Blind
Voss, Patrice; Lepore, Franco; Gougoux, Frédéric; Zatorre, Robert J.
2011-01-01
We have previously shown that some blind individuals can localize sounds more accurately than their sighted counterparts when one ear is obstructed, and that this ability is strongly associated with occipital cortex activity. Given that spectral cues are important for monaurally localizing sounds when one ear is obstructed, and that blind individuals are more sensitive to small spectral differences, we hypothesized that enhanced use of spectral cues via occipital cortex mechanisms could explain the better performance of blind individuals in monaural localization. Using positron-emission tomography (PET), we scanned blind and sighted persons as they discriminated between sounds originating from a single spatial position, but with different spectral profiles that simulated different spatial positions based on head-related transfer functions. We show here that a sub-group of early blind individuals showing superior monaural sound localization abilities performed significantly better than any other group on this spectral discrimination task. For all groups, performance was best for stimuli simulating peripheral positions, consistent with the notion that spectral cues are more helpful for discriminating peripheral sources. PET results showed that all blind groups showed cerebral blood flow increases in the occipital cortex; but this was also the case in the sighted group. A voxel-wise covariation analysis showed that more occipital recruitment was associated with better performance across all blind subjects but not the sighted. An inter-regional covariation analysis showed that the occipital activity in the blind covaried with that of several frontal and parietal regions known for their role in auditory spatial processing. Overall, these results support the notion that the superior ability of a sub-group of early-blind individuals to localize sounds is mediated by their superior ability to use spectral cues, and that this ability is subserved by cortical processing in the occipital cortex. PMID:21716600
Näsholm, Erika; Rohlfing, Sarah; Sauer, James D.
2014-01-01
Closed Circuit Television (CCTV) operators are responsible for maintaining security in various applied settings. However, research has largely ignored human factors that may contribute to CCTV operator error. One important source of error is inattentional blindness – the failure to detect unexpected but clearly visible stimuli when attending to a scene. We compared inattentional blindness rates for experienced (84 infantry personnel) and naïve (87 civilians) operators in a CCTV monitoring task. The task-relevance of the unexpected stimulus and the length of the monitoring period were manipulated between participants. Inattentional blindness rates were measured using typical post-event questionnaires, and participants' real-time descriptions of the monitored event. Based on the post-event measure, 66% of the participants failed to detect salient, ongoing stimuli appearing in the spatial field of their attentional focus. The unexpected task-irrelevant stimulus was significantly more likely to go undetected (79%) than the unexpected task-relevant stimulus (55%). Prior task experience did not inoculate operators against inattentional blindness effects. Participants' real-time descriptions revealed similar patterns, ruling out inattentional amnesia accounts. PMID:24465932
Magalhães, Fernando Henrique; Kohn, André Fabio
2011-08-01
Diminished balance ability poses a serious health risk due to the increased likelihood of falling, and impaired postural stability is significantly associated with blindness and poor vision. Noise stimulation (by improving the detection of sub-threshold somatosensory information) and tactile supplementation (i.e., additional haptic information provided by an external contact surface) have been shown to improve the performance of the postural control system. Moreover, vibratory noise added to the source of tactile supplementation (e.g., applied to a surface that the fingertip touches) has been shown to enhance balance stability more effectively than tactile supplementation alone. In view of the above findings, in addition to the well established consensus that blind subjects show superior abilities in the use of tactile information, we hypothesized that blind subjects may take extra benefits from the vibratory noise added to the tactile supplementation and hence show greater improvements in postural stability than those observed for sighted subjects. If confirmed, this hypothesis may lay the foundation for the development of noise-based assistive devices (e.g., canes, walking sticks) for improving somatosensation and hence prevent falls in blind individuals. Copyright © 2011 Elsevier Ltd. All rights reserved.
20 CFR 404.1519p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4) Whether this is... management studies on the quality of consultative examinations purchased from major medical sources and the...
20 CFR 404.1519p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4) Whether this is... management studies on the quality of consultative examinations purchased from major medical sources and the...
20 CFR 404.1519p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4) Whether this is... management studies on the quality of consultative examinations purchased from major medical sources and the...
20 CFR 404.1519p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4) Whether this is... management studies on the quality of consultative examinations purchased from major medical sources and the...
20 CFR 404.1519p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4) Whether this is... management studies on the quality of consultative examinations purchased from major medical sources and the...
Cataract, ocular surgery, aphakia, and the chromatic expression of the painter Jovan Bijelić.
Nikolić, Ljubiša; Jovanović, Vesna
2016-11-01
Approaching art from the standpoint of optics and the artist’s eye pathology can sometimes explain the shift of the spectral colors in the work of some artists with cataract and aphakia. This may not be obvious in the paintings of other artists with the same eye pathology. The aim of this study was to create a timeline from the recently obtained details of the cataract surgery, his best corrected aphakic visual acuity, and the last paintings of the artist Jovan Bijelić. The research included primary and secondary source material: Bijelić’s paintings from all stages of his career, interviews with Bijelić and his eye surgeon, art criticism, sources with the description of Bijelić’s symptoms, hospital archives, discussion with art historians, comparison of his palette from different periods. Jovan Bijelić was nearly blind from cataract in 1957. He underwent an unsuccessful cataract surgery in 1956, followed by enucleation of the operated eye. In 1958, 20/25–20/20 vision was regained, after the extracapsular cataract extraction and sector iridectomy in his right eye, with the posterior lens capsule discision afterwards. Xanthopsia and cyanopsia are not present in his art, which is not a representation of visualized objects. The response of Jovan Bijelić to cataract and aphakia was predominantly a change of his style.
Retinal fundus images for glaucoma analysis: the RIGA dataset
NASA Astrophysics Data System (ADS)
Almazroa, Ahmed; Alodhayb, Sami; Osman, Essameldin; Ramadan, Eslam; Hummadi, Mohammed; Dlaim, Mohammed; Alkatee, Muhannad; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan
2018-03-01
Glaucoma neuropathy is a major cause of irreversible blindness worldwide. Current models of chronic care will not be able to close the gap of growing prevalence of glaucoma and challenges for access to healthcare services. Teleophthalmology is being developed to close this gap. In order to develop automated techniques for glaucoma detection which can be used in tele-ophthalmology we have developed a large retinal fundus dataset. A de-identified dataset of retinal fundus images for glaucoma analysis (RIGA) was derived from three sources for a total of 750 images. The optic cup and disc boundaries for each image was marked and annotated manually by six experienced ophthalmologists and included the cup to disc (CDR) estimates. Six parameters were extracted and assessed (the disc area and centroid, cup area and centroid, horizontal and vertical cup to disc ratios) among the ophthalmologists. The inter-observer annotations were compared by calculating the standard deviation (SD) for every image between the six ophthalmologists in order to determine if the outliers amongst the six and was used to filter the corresponding images. The data set will be made available to the research community in order to crowd source other analysis from other research groups in order to develop, validate and implement analysis algorithms appropriate for tele-glaucoma assessment. The RIGA dataset can be freely accessed online through University of Michigan, Deep Blue website (doi:10.7302/Z23R0R29).
PyEEG: an open source Python module for EEG/MEG feature extraction.
Bao, Forrest Sheng; Liu, Xin; Zhang, Christina
2011-01-01
Computer-aided diagnosis of neural diseases from EEG signals (or other physiological signals that can be treated as time series, e.g., MEG) is an emerging field that has gained much attention in past years. Extracting features is a key component in the analysis of EEG signals. In our previous works, we have implemented many EEG feature extraction functions in the Python programming language. As Python is gaining more ground in scientific computing, an open source Python module for extracting EEG features has the potential to save much time for computational neuroscientists. In this paper, we introduce PyEEG, an open source Python module for EEG feature extraction.
PyEEG: An Open Source Python Module for EEG/MEG Feature Extraction
Bao, Forrest Sheng; Liu, Xin; Zhang, Christina
2011-01-01
Computer-aided diagnosis of neural diseases from EEG signals (or other physiological signals that can be treated as time series, e.g., MEG) is an emerging field that has gained much attention in past years. Extracting features is a key component in the analysis of EEG signals. In our previous works, we have implemented many EEG feature extraction functions in the Python programming language. As Python is gaining more ground in scientific computing, an open source Python module for extracting EEG features has the potential to save much time for computational neuroscientists. In this paper, we introduce PyEEG, an open source Python module for EEG feature extraction. PMID:21512582
NASA Astrophysics Data System (ADS)
Mochalskyy, Serhiy; Fantz, Ursel; Wünderlich, Dirk; Minea, Tiberiu
2016-10-01
The development of negative ion (NI) sources for the ITER neutral beam injector is strongly accompanied by modelling activities. The ONIX (Orsay Negative Ion eXtraction) code simulates the formation and extraction of negative hydrogen ions and co-extracted electrons produced in caesiated sources. In this paper the 3D geometry of the BATMAN extraction system, and the source characteristics such as the extraction and bias potential, and the 3D magnetic field were integrated in the model. Calculations were performed using plasma parameters experimentally obtained on BATMAN. The comparison of the ONIX calculated extracted NI density with the experimental results suggests that predictive calculations of the extraction of NIs are possible. The results show that for an ideal status of the Cs conditioning the extracted hydrogen NI current density could reach ~30 mA cm-2 at 10 kV and ~20 mA cm-2 at 5 kV extraction potential, with an electron/NI current density ratio of about 1, as measured in the experiments under the same plasma and source conditions. The dependency of the extracted NI current on the NI density in the bulk plasma region from both the modeling and the experiment was investigated. The separate distributions composing the NI beam originating from the plasma bulk region and the PG surface are presented for different NI plasma volume densities and NI emission rates from the plasma grid (PG) wall, respectively. The extracted current from the NIs produced at the Cs covered PG surface, initially moving towards the bulk plasma and then being bent towards the extraction surfaces, is lower compared to the extracted NI current from directly extracted surface produced ions.
An, Jee Hyun; Kim, Dong-Lim; Lee, Tae-Bum; Kim, Kyeong Jin; Kim, Sun Hwa; Kim, Nam Hoon; Kim, Hee Young; Choi, Dong Seop; Kim, Sin Gon
2016-10-01
Rubus occidentalis (RO) has beneficial effects on glucose and lipid profiles in vitro. The aim of the study was to investigate RO extract effect on metabolic parameters in prediabetic patients, adopting a 12-week, randomized, double-blind, placebo-controlled trial. Forty-four patients (age 59.0 ± 8.2 years, 70.5% females, HbA1c 5.8 ± 0.4%) were divided into placebo (n = 13), low-dose RO extract (LRE; n = 14), or high-dose RO extract (HRE; n = 17) groups. Either 900 or 1800 mg per day of RO extract was administered orally. Area under the curve for glucose obtained 2 h after a 75-g oral glucose tolerance test was significantly decreased in the HRE group, compared with the placebo group (-28.1 ± 42.4 vs. +13.4 ± 52.6 mg/dL, p < 0.05). Homoeostasis model assessment-B was increased (+17.11 ± 10.69, +5.24 ± 4.10, and +0.86 ± 6.01 in HRE, LRE, and placebo, respectively, p < 0.05). Serum levels of monocyte chemoattractant protein-1 and oxidized low-density lipoprotein were significantly decreased by treatment in a dose-dependent manner (monocyte chemoattractant protein-1: -35.0 ± 21.2, +8.4 ± 18.1, and +24.2 ± 14.5; oxidized low-density lipoprotein: -19.7 ± 8.5, -13.1 ± 7.2, and -2.2 ± 11.0 in the HRE, LRE, and placebo, respectively, p < 0.05). The results support the beneficial effects of RO extract on the control of glycemia and vascular inflammation in prediabetic patients. (ClinicalTrials.gov: NCT01964703). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Parvizi, Mohammad Mahdi; Moein, Mahmoodreza; Hatam, Gholamreza; Nimrouzi, Majid; Hassanzadeh, Jafar; Hamidizadeh, Nasrin; Khorrami, Hamid Reza; Zarshenas, Mohammad Mehdi
2017-01-01
Background Cutaneous leishmaniasis is one of the highly prevalent endemic diseases in the Middle East and North Africa. Many treatment modalities have been recommended for this condition but success rates remain limited. Herbal remedies have also been used for treatment but evidence-based clinical trials with these products are sparse. In-vitro and in-vivo studies have shown the anti-leishmanial and curative effects of extract of fruits and leaves of Juniperus excelsa (J. excelsa). The aim of this study was to determine the efficacy of topical J. excelsa M. Bieb extract as an adjuvant to cryotherapy for the treatment of human CL. Materials and methods This study was designed as a two-arm triple-blind randomized placebo-controlled clinical trial using a parallel design. Seventy-two patients with clinical diagnosis of CL confirmed by leishmania smears were allocated to receive either a topical formulation of leaf of J. excelsa extract (group A) or placebo (group B) for 3 months. Both groups received cryotherapy as baseline standard treatment. Patients were evaluated before and weekly after the intervention was initiated until complete cure. Results Overall, 82% of patients in group A, experienced complete cure and 9% of them had partial cure. On the other hand, 34% in group B reported complete cure, while 14% of them had partial cure at the end of treatment protocol with a significant difference between the two groups (P< 0.001). The mean duration to healing of the lesions in patients who received J. excelsa extract was statistically significantly shorter than the placebo group (p = 0.04). No significant side effect was seen in the J. excelsa extract group except for mild to moderate local irritation after a few weeks in a few numbers of patients. Conclusion The results of this study showed that topical J. excelsa extract can be used as an adjuvant treatment modality in addition to cryotherapy for accelerating the time to cure in addition to increasing the complete cure rate in CL. Trial registration ClinicalTrials.gov IRCT2015082523753N1 PMID:28981503
Pantuck, A J; Pettaway, C A; Dreicer, R; Corman, J; Katz, A; Ho, A; Aronson, W; Clark, W; Simmons, G; Heber, D
2015-09-01
The primary objective of this study was to compare the effects of pomegranate juice on PSA doubling times (PSADT) in subjects with rising PSA levels after primary therapy for prostate cancer. Double-blind, placebo-controlled multi-institutional study, evaluated the effects of pomegranate liquid extract on serum PSA levels. The primary end point of this study was change in serum PSADT. Additional secondary and exploratory objectives were to evaluate the safety of pomegranate juice and to determine the interaction of manganese superoxide dismutase (MnSOD) AA genotype and pomegranate treatment on PSADT. One-hundred eighty-three eligible subjects were randomly assigned to the active and placebo groups with a ratio of 2:1 (extract N=102; placebo N=64; juice N=17). The majority of adverse events were of moderate or mild grade. Median PSADT increased from 11.1 months at baseline to 15.6 months in the placebo group (P<0.001) compared with an increase from 12.9 months at baseline to 14.5 months in the extract group (P=0.13) and an increase from 12.7 at baseline to 20.3 in the juice group (P=0.004). However, none of these changes were statistically significant between the three groups (P>0.05). Placebo AA patients experienced a 1.8 month change in median PSADT from 10.9 months at baseline to 12.7 months (P=0.22), while extract patients experienced a 12 month change in median PSADT from 13.6 at baseline to 25.6 months (P=0.03). Compared with placebo, pomegranate extract did not significantly prolong PSADT in prostate cancer patients with rising PSA after primary therapy. A significant prolongation in PSADT was observed in both the treatment and placebo arms. Men with the MnSOD AA genotype may represent a group that is more sensitive to the antiproliferative effects of pomegranate on PSADT; however, this finding requires prospective hypothesis testing and validation.
Matawle, Jeevan Lal; Pervez, Shamsh; Deb, Manas Kanti; Shrivastava, Anjali; Tiwari, Suresh
2018-02-01
USEPA's UNMIX, positive matrix factorization (PMF) and effective variance-chemical mass balance (EV-CMB) receptor models were applied to chemically speciated profiles of 125 indoor PM 2.5 measurements, sampled longitudinally during 2012-2013 in low-income group households of Central India which uses solid fuels for cooking practices. Three step source apportionment studies were carried out to generate more confident source characterization. Firstly, UNMIX6.0 extracted initial number of source factors, which were used to execute PMF5.0 to extract source-factor profiles in second step. Finally, factor analog locally derived source profiles were supplemented to EV-CMB8.2 with indoor receptor PM 2.5 chemical profile to evaluate source contribution estimates (SCEs). The results of combined use of three receptor models clearly describe that UNMIX and PMF are useful tool to extract types of source categories within small receptor dataset and EV-CMB can pick those locally derived source profiles for source apportionment which are analog to PMF-extracted source categories. The source apportionment results have also shown three fold higher relative contribution of solid fuel burning emissions to indoor PM 2.5 compared to those measurements reported for normal households with LPG stoves. The previously reported influential source marker species were found to be comparatively similar to those extracted from PMF fingerprint plots. The comparison between PMF and CMB SCEs results were also found to be qualitatively similar. The performance fit measures of all three receptor models were cross-verified and validated and support each other to gain confidence in source apportionment results.
Assessment of Hydroacoustic Propagation Using Autonomous Hydrophones in the Scotia Sea
2010-09-01
Award No. DE-AI52-08NA28654 Proposal No. BAA08-36 ABSTRACT The remote area of the Atlantic Ocean near the Antarctic Peninsula and the South...hydroacoustic blind spot. To investigate the sound propagation and interferences affected by these landmasses in the vicinity of the Antarctic polar...from large icebergs (near-surface sources) were utilized as natural sound sources. Surface sound sources, e.g., ice-related events, tend to suffer less
Scollo, M; Lal, A; Hyland, A; Glantz, S
2003-01-01
Data sources: Researchers sought all studies produced before 31 August 2002. Articles published in scientific journals were located with Medline, Science Citation Index, Social Sciences Citation Index, Current Contents, PsychInfo, Econlit, and Healthstar. Unpublished studies were located from tobacco company websites and through internet searches. Study selection: 97 studies that made statements about economic impact were included. 93% of the studies located met the selection criteria as determined by consensus between multiple reviewers. Data extraction: Findings and characteristics of studies (apart from funding source) were classified independently by two researchers. A third assessor blind to both the objective of the present study and to funding source also classified each study. Data synthesis: In studies concluding a negative impact, the odds of using a subjective outcome measure was 4.0 times (95% confidence interval (CI) 1.4 to 9.6; p = 0.007) and the odds of not being peer reviewed was 20 times (95% CI 2.6 to 166.7; p = 0.004) that of studies concluding no such negative impact. All of the studies concluding a negative impact were supported by the tobacco industry. 94% of the tobacco industry supported studies concluded a negative economic impact compared to none of the non-industry supported studies. Conclusion: All of the best designed studies report no impact or a positive impact of smoke-free restaurant and bar laws on sales or employment. Policymakers can act to protect workers and patrons from the toxins in secondhand smoke confident in rejecting industry claims that there will be an adverse economic impact. PMID:12612356
NASA Astrophysics Data System (ADS)
Wu, J.; Clark, C. J.; Pletsch, H. J.; Guillemot, L.; Johnson, T. J.; Torne, P.; Champion, D. J.; Deneva, J.; Ray, P. S.; Salvetti, D.; Kramer, M.; Aulbert, C.; Beer, C.; Bhattacharyya, B.; Bock, O.; Camilo, F.; Cognard, I.; Cuéllar, A.; Eggenstein, H. B.; Fehrmann, H.; Ferrara, E. C.; Kerr, M.; Machenschalk, B.; Ransom, S. M.; Sanpa-Arsa, S.; Wood, K.
2018-02-01
We report on the analysis of 13 gamma-ray pulsars discovered in the Einstein@Home blind search survey using Fermi Large Area Telescope (LAT) Pass 8 data. The 13 new gamma-ray pulsars were discovered by searching 118 unassociated LAT sources from the third LAT source catalog (3FGL), selected using the Gaussian Mixture Model machine-learning algorithm on the basis of their gamma-ray emission properties being suggestive of pulsar magnetospheric emission. The new gamma-ray pulsars have pulse profiles and spectral properties similar to those of previously detected young gamma-ray pulsars. Follow-up radio observations have revealed faint radio pulsations from two of the newly discovered pulsars and enabled us to derive upper limits on the radio emission from the others, demonstrating that they are likely radio-quiet gamma-ray pulsars. We also present results from modeling the gamma-ray pulse profiles and radio profiles, if available, using different geometric emission models of pulsars. The high discovery rate of this survey, despite the increasing difficulty of blind pulsar searches in gamma rays, suggests that new systematic surveys such as presented in this article should be continued when new LAT source catalogs become available.
2007-12-14
contained dried residues from a collection of terrestrial plants , marine inver- tebrates, and various fungi. NCI plate numbers, sources of extracts, and... plants ), while Fig. 3B displays results from row G of the same plate. In these examples, wells B3, B5, B9, G9, and G12 were selected for further...sources of extracts Plate no. Source Extraction solvent 96110120 Terrestrial plants Water 96110125 Terrestrial plants CH3OH-CH2Cl2 12000707 Marine
Bayley, K Bruce; Belnap, Tom; Savitz, Lucy; Masica, Andrew L; Shah, Nilay; Fleming, Neil S
2013-08-01
To document the strengths and challenges of using electronic health records (EHRs) for comparative effectiveness research (CER). A replicated case study of comparative effectiveness in hypertension treatment was conducted across 4 health systems, with instructions to extract data and document problems encountered using a specified list of required data elements. Researchers at each health system documented successes and challenges, and suggested solutions for addressing challenges. Data challenges fell into 5 categories: missing data, erroneous data, uninterpretable data, inconsistencies among providers and over time, and data stored in noncoded text notes. Suggested strategies to address these issues include data validation steps, use of surrogate markers, natural language processing, and statistical techniques. A number of EHR issues can hamper the extraction of valid data for cross-health system comparative effectiveness studies. Our case example cautions against a blind reliance on EHR data as a single definitive data source. Nevertheless, EHR data are superior to administrative or claims data alone, and are cheaper and timelier than clinical trials or manual chart reviews. All 4 participating health systems are pursuing pathways to more effectively use EHR data for CER.A partnership between clinicians, researchers, and information technology specialists is encouraged as a way to capitalize on the wealth of information contained in the EHR. Future developments in both technology and care delivery hold promise for improvement in the ability to use EHR data for CER.
Nonoperative Treatment in Lumbar Spondylolysis and Spondylolisthesis
Garet, Matthew; Reiman, Michael P.; Mathers, Jessie; Sylvain, Jonathan
2013-01-01
Context: Both spondylolysis and spondylolisthesis can be diagnosed across the life span of sports-participating individuals. Determining which treatments are effective for these conditions is imperative to the rehabilitation professional. Data Sources: A computer-assisted literature search was completed in MEDLINE, CINAHL, and EMBASE databases (1966-April 2012) utilizing keywords related to nonoperative treatment of spondylolysis and/or spondylolisthesis. Reference lists were also searched to find all relevant articles that fit our inclusion criteria: English language, human, lumbar pain with diagnosed spondylolysis and/or spondylolisthesis, inclusion of at least 1 nonoperative treatment method, and use of a comparative study design. Data Extraction: Data were independently extracted from the selected studies by 2 authors and cross-referenced. Any disagreement on relevant data was discussed and resolved by a third author. Results: Ten studies meeting the criteria were rated for quality using the GRADE scale. Four studies found surgical intervention more successful than nonoperative treatment for treating pain and functional limitation. One study found no difference between surgery and nonoperative treatment with regard to future low back pain. Improvement was found in bracing, bracing and exercises emphasizing lumbar extension, range of motion and strengthening exercises focusing on lumbar flexion, and strengthening specific abdominal and lumbar muscles. Conclusion: No consensus can be reached on the role of nonoperative versus surgical care because of limited investigation and heterogeneity of studies reported. Studies of nonoperative care options suffered from lack of blinding assessors and control groups and decreased patient compliance with exercise programs. PMID:24427393
NASA Astrophysics Data System (ADS)
Dong, Chun; He, Gen; Mai, Kangsen; Zhou, Huihui; Xu, Wei
2016-06-01
Poor palatability is a limiting factor for replacing fishmeal with other protein sources in aquaculture. The water-soluble molecules with low molecular weights are the major determinants of the palatability of diets. The present study was conducted to investigate the palatability of water-soluble extracts from single protein source (single extract pellets) and the mixture of these extracts with different proportions (blended extract pellets) in juvenile turbot ( Scophthalmus maximus). Then according to the palatability of blended extract pellets, an optimal mixture proportion was selected, and a new protein source made from raw protein materials with the selected proportion was formulated to replace fishmeal. Summarily, the palatability of single extract pellets for turbot was descendent from fishmeal to pet-food grade poultry by-product meal, wheat gluten meal, soybean meal, peanut meal, meat and bone meal, and corn gluten meal. Subsequently, according to the palatability of single extract pellets, 52 kinds of blended extract pellets were designed to test their palatability. The results showed that the pellets presented remarkably different palatability, and the optimal one was diet 52 (wheat gluten meal: pet-food grade poultry by-product meal: meat and bone meal: corn gluten meal = 1:6:1:2). The highest ingestion ratio (the number of pellets ingested/the number of pellets fed) was 0.73 ± 0.03, which was observed in Diet 52. Then five isonitrogenous (52% crude protein) and isocaloric (20 kJ g-1 gross energy) diets were formulated by replacing 0 (control), 35%, 50%, 65% and 80% of fishmeal with No.52 blending proportion. After a 10-weeks feeding trial, a consistent feed intake was found among all replacement treatments. Replacement level of fishmeal up to 35% did not significantly influence final body weight, specific growth rate, feed efficiency ratio, and protein efficiency ratio of turbot. Therefore, the water-soluble extracts of protein sources play an important role in improving the palatability of non-fishmeal protein sources in aquafeed.
Hawthorn extract for treating chronic heart failure.
Pittler, M H; Guo, R; Ernst, E
2008-01-23
Hawthorn extract is advocated as an oral treatment option for chronic heart failure. Also, the German Commission E approved the use of extracts of hawthorn leaf with flower in patients suffering from heart failure graded stage II according to the New York Heart Association. To assess the benefits and harms as reported in double-blind randomised clinical trials of hawthorn extract compared with placebo for treating patients with chronic heart failure. We searched CENTRAL on The Cochrane Library (issue 2, 2006), MEDLINE (1951 to June 2006), EMBASE (1974 to June 2006), CINAHL (1982 to June 2006) and AMED (1985 to June 2006). Experts and manufacturers were contacted. Language restrictions were not imposed. To be included, studies were required to state that they were randomised, double-blind, and placebo controlled, and used hawthorn leaf and flower extract monopreparations. Two reviewers independently performed the selection of studies, data extraction, and assessment of methodological quality. Data were entered into RevMan 4.2 software. Results from continuous data were reported as weighted mean difference (WMD) with 95% confidence interval (CI). Where data were suitable for combining, pooled results were calculated. Fourteen trials met all inclusion criteria and were included in this review. In most of the studies, hawthorn was used as an adjunct to conventional treatment. Ten trials including 855 patients with chronic heart failure (New York Heart Association classes I to III) provided data that were suitable for meta-analysis. For the physiologic outcome of maximal workload, treatment with hawthorn extract was more beneficial than placebo (WMD (Watt) 5.35, 95% CI 0.71 to 10.00, P < 0.02, n = 380). Exercise tolerance were significantly increased by hawthorn extract (WMD (Watt x min) 122.76, 95% CI 32.74 to 212.78, n = 98). The pressure-heart rate product, an index of cardiac oxygen consumption, also showed a beneficial decrease with hawthorn treatment (WMD (mmHg/min) -19.22, 95% CI -30.46 to -7.98, n = 264). Symptoms such as shortness of breath and fatigue improved significantly with hawthorn treatment as compared with placebo (WMD -5.47, 95% CI -8.68 to -2.26, n = 239). No data on relevant mortality and morbidity such as cardiac events were reported, apart from one trial, which reported deaths (three in active, one in control) without providing further details. Reported adverse events were infrequent, mild, and transient; they included nausea, dizziness, and cardiac and gastrointestinal complaints. These results suggest that there is a significant benefit in symptom control and physiologic outcomes from hawthorn extract as an adjunctive treatment for chronic heart failure.
20 CFR 416.919p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... evidence in the file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4... major medical sources and the appropriateness of the examinations authorized. (e) We will take steps to...
20 CFR 416.919p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... evidence in the file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4... major medical sources and the appropriateness of the examinations authorized. (e) We will take steps to...
20 CFR 416.919p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... evidence in the file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4... major medical sources and the appropriateness of the examinations authorized. (e) We will take steps to...
20 CFR 416.919p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... evidence in the file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4... major medical sources and the appropriateness of the examinations authorized. (e) We will take steps to...
20 CFR 416.919p - Reviewing reports of consultative examinations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... evidence in the file (e.g., your blindness in one eye, amputations, pain, alcoholism, depression); (4... major medical sources and the appropriateness of the examinations authorized. (e) We will take steps to...
Investigation of automated feature extraction using multiple data sources
NASA Astrophysics Data System (ADS)
Harvey, Neal R.; Perkins, Simon J.; Pope, Paul A.; Theiler, James P.; David, Nancy A.; Porter, Reid B.
2003-04-01
An increasing number and variety of platforms are now capable of collecting remote sensing data over a particular scene. For many applications, the information available from any individual sensor may be incomplete, inconsistent or imprecise. However, other sources may provide complementary and/or additional data. Thus, for an application such as image feature extraction or classification, it may be that fusing the mulitple data sources can lead to more consistent and reliable results. Unfortunately, with the increased complexity of the fused data, the search space of feature-extraction or classification algorithms also greatly increases. With a single data source, the determination of a suitable algorithm may be a significant challenge for an image analyst. With the fused data, the search for suitable algorithms can go far beyond the capabilities of a human in a realistic time frame, and becomes the realm of machine learning, where the computational power of modern computers can be harnessed to the task at hand. We describe experiments in which we investigate the ability of a suite of automated feature extraction tools developed at Los Alamos National Laboratory to make use of multiple data sources for various feature extraction tasks. We compare and contrast this software's capabilities on 1) individual data sets from different data sources 2) fused data sets from multiple data sources and 3) fusion of results from multiple individual data sources.
Developing the RAL front end test stand source to deliver a 60 mA, 50 Hz, 2 ms H- beam
NASA Astrophysics Data System (ADS)
Faircloth, Dan; Lawrie, Scott; Letchford, Alan; Gabor, Christoph; Perkins, Mike; Whitehead, Mark; Wood, Trevor; Tarvainen, Olli; Komppula, Jani; Kalvas, Taneli; Dudnikov, Vadim; Pereira, Hugo; Izaola, Zunbeltz; Simkin, John
2013-02-01
All the Front End Test Stand (FETS) beam requirements have been achieved, but not simultaneously [1]. At 50 Hz repetition rates beam current droop becomes unacceptable for pulse lengths longer than 1 ms. This is fundamental limitation of the present source design. Previous researchers [2] have demonstrated that using a physically larger Penning surface plasma source should overcome these limitations. The scaled source development strategy is outlined in this paper. A study of time-varying plasma behavior has been performed using a V-UV spectrometer. Initial experiments to test scaled plasma volumes are outlined. A dedicated plasma and extraction test stand (VESPA-Vessel for Extraction and Source Plasma Analysis) is being developed to allow new source and extraction designs to be appraised. The experimental work is backed up by modeling and simulations. A detailed ANSYS thermal model has been developed. IBSimu is being used to design extraction and beam transport. A novel 3D plasma modeling code using beamlets is being developed by Cobham Vector Fields using SCALA OPERA, early source modeling results are very promising. Hardware on FETS is also being developed in preparation to run the scaled source. A new 2 ms, 50 Hz, 25 kV pulsed extraction voltage power supply has been constructed and a new discharge power supply is being designed. The design of the post acceleration electrode assembly has been improved.
Azuara-Blanco, Augusto; Burr, Jennifer M; Cochran, Claire; Ramsay, Craig; Vale, Luke; Foster, Paul; Friedman, David; Quayyum, Zahidul; Lai, Jimmy; Nolan, Winnie; Aung, Tin; Chew, Paul; McPherson, Gladys; McDonald, Alison; Norrie, John
2011-05-23
Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. ISRCTN44464607.
Lawrie, S R; Faircloth, D C; Letchford, A P; Perkins, M; Whitehead, M O; Wood, T; Gabor, C; Back, J
2014-02-01
The ISIS pulsed spallation neutron and muon facility at the Rutherford Appleton Laboratory (RAL) in the UK uses a Penning surface plasma negative hydrogen ion source. Upgrade options for the ISIS accelerator system demand a higher current, lower emittance beam with longer pulse lengths from the injector. The Front End Test Stand is being constructed at RAL to meet the upgrade requirements using a modified ISIS ion source. A new 10% duty cycle 25 kV pulsed extraction power supply has been commissioned and the first meter of 3 MeV radio frequency quadrupole has been delivered. Simultaneously, a Vessel for Extraction and Source Plasma Analyses is under construction in a new laboratory at RAL. The detailed measurements of the plasma and extracted beam characteristics will allow a radical overhaul of the transport optics, potentially yielding a simpler source configuration with greater output and lifetime.
2013-01-01
Background Pain following surgical removal of impacted molars has remained an important concern among practitioners. Various protocols have been proposed to reduce postoperative pain. However, each one has special side effects and limitations. As green tea possesses anti-inflammatory and antibacterial properties, the aim of the current study was to evaluate the effectiveness of green tea mouthwash in controlling postoperative pain. Materials and methods In a study with split-mouth and double blind design, 44 patients in need of bilateral removal of impacted third molars underwent randomized surgical extraction; following one surgery patients rinsed with a green tea mouthwash from the first to seventh postoperative day and after other extraction rinsed with placebo mouthwash in the same duration. Both patients and surgeon were blinded to the type of mouthwash. The predictor variable was type of mouthwash and primary outcome variable was postoperative pain measured by visual analogue scale (VAS) during first week after surgery. In addition, number of analgesics patients used after surgery recorded. To measure the effect of green tea mouthwash, repeated measures test with confidence interval of 95% was performed. Results Total of 43 patients with mean age of 24 years underwent total of 86 surgeries. VAS value had no statistically difference prior rinsing among groups (P-value > 0.05). However, the mean value of VAS following rinsing with green tea was statistically lower than placebo in postoperative days of 3–7 (P-value < 0.05). In addition, while rinsing with green tea, patients took significantly lower number of analgesics after surgery (P-value < 0.05). No side effects reported. Conclusion Green tea mouthwash could be an appropriate and safe choice to control postoperative pain after third molar surgery. PMID:23866761
Ghahari, S. F.; Abazarsa, F.; Avci, O.; Çelebi, Mehmet; Taciroglu, E.
2016-01-01
The Robert A. Millikan Library is a reinforced concrete building with a basement level and nine stories above the ground. Located on the campus of California Institute of Technology (Caltech) in Pasadena California, it is among the most densely instrumented buildings in the U.S. From the early dates of its construction, it has been the subject of many investigations, especially regarding soil–structure interaction effects. It is well accepted that the structure is significantly interacting with the surrounding soil, which implies that the true foundation input motions cannot be directly recorded during earthquakes because of inertial effects. Based on this limitation, input–output modal identification methods are not applicable to this soil–structure system. On the other hand, conventional output-only methods are typically based on the unknown input signals to be stationary whitenoise, which is not the case for earthquake excitations. Through the use of recently developed blind identification (i.e. output-only) methods, it has become possible to extract such information from only the response signals because of earthquake excitations. In the present study, we employ such a blind identification method to extract the modal properties of the Millikan Library. We present some modes that have not been identified from force vibration tests in several studies to date. Then, to quantify the contribution of soil–structure interaction effects, we first create a detailed Finite Element (FE) model using available information about the superstructure; and subsequently update the soil–foundation system's dynamic stiffnesses at each mode such that the modal properties of the entire soil–structure system agree well with those obtained via output-only modal identification.
1988-10-26
concentrated into this off- axis peak is then considered. Estimates of the source brightness ( extraction ion diode source current density divided by the square...radioactive contamination of the accelerator. One possible scheme for avoiding this problem is to use extraction geometry ion diodes to focus the ion beams...annular region. These results will be coupled to two simple models of extraction ion diodes to determihe the ion source brightness requirements. These
Exercise for Improving Age-Related Hyperkyphotic Posture: A Systematic Review
Bansal, Symron; Katzman, Wendy B.; Giangregorio, Lora M.
2014-01-01
Objective To evaluate previous research to determine if exercise can improve preexisting hyperkyphosis by decreasing the angle of thoracic kyphosis in adults aged ≥45 years. Data Sources PubMed, Embase, and the Cumulative Index to Nursing and Allied Health Literature databases were searched for studies related to posture, exercise, and age ≥45 years. Online conference proceedings of the American Society for Bone and Mineral Research, American Physical Therapy Association, and Gerontological Society of America were also searched. Study Selection Two independent reviewers screened the titles and abstracts and selected studies that tested the effect of exercise on measures of kyphosis, or forward head posture, in individuals with hyperkyphosis at baseline (defined as angle of kyphosis ≥40°). Reviews, letters, notes, and non-English language studies were excluded. Data Extraction A pilot-tested abstraction form was used by each reviewer to extract data from each study regarding details of exercise intervention, participant characteristics, safety, adherence, and results. The Cochrane Collaboration’s tool for assessing risk of bias was used to assess methodologic quality. Discrepancies on the abstraction forms between the 2 reviewers were resolved by a third reviewer. A formal meta-analysis was not performed. Data Synthesis Thirteen studies were abstracted and included in the review; of these, 8 studies saw improvements in ≥1 measure of posture. The main sources of bias were related to blinding participants and incomplete outcome data. The adherence reported across studies suggests that exercise is an acceptable intervention for individuals with age-related hyperkyphosis. Conclusions The scarcity and quality of available data did not permit a pooled estimate of the effect of exercise on hyperkyphotic posture; however, the positive effects observed in high-quality studies suggest some benefit and support the need for an adequately designed randomized controlled trial examining the effect of exercise on hyperkyphosis. PMID:23850611
Cone-shaped source characteristics and inductance effect of transient electromagnetic method
NASA Astrophysics Data System (ADS)
Yang, Hai-Yan; Li, Feng-Ping; Yue, Jian-Hua; Guo, Fu-Sheng; Liu, Xu-Hua; Zhang, Hua
2017-03-01
Small multi-turn coil devices are used with the transient electromagnetic method (TEM) in areas with limited space, particularly in underground environments such as coal mines roadways and engineering tunnels, and for detecting shallow geological targets in environmental and engineering fields. However, the equipment involved has strong mutual inductance coupling, which causes a lengthy turn-offtime and a deep "blind zone". This study proposes a new transmitter device with a conical-shape source and derives the radius formula of each coil and the mutual inductance coefficient of the cone. According to primary field characteristics, results of the two fields created, calculation of the conical-shaped source in a uniform medium using theoretical analysis, and a comparison of the inductance of the new device with that of the multi-turn coil, show that inductance of the multi-turn coil is nine times greater than that of the conical source with the same equivalent magnetic moment of 926.1 A·m2. This indicates that the new source leads to a much shallower "blind zone." Furthermore, increasing the bottom radius and turn of the cone creates a larger mutual inductance but increasing the cone height results in a lower mutual inductance. Using the superposition principle, the primary and secondary magnetic fields for a conical source in a homogeneous medium are calculated; results indicate that the magnetic behavior of the cone is the same as that of the multi-turn coils, but the transient responses of the secondary field and the total field are more stronger than those of the multi-turn coils. To study the transient response characteristics using a cone-shaped source in a layered earth, a numerical filtering algorithm is then developed using the fast Hankel transform and the improved cosine transform, again using the superposition principle. During development, an average apparent resistivity inverted from the induced electromotive force using each coil is defined to represent the comprehensive resistivity of the conical source. To verify the forward calculation method, the transient responses of H type models and KH type models are calculated, and data are inverted using a "smoke ring" inversion. The results of inversion have good agreement with original models and show that the forward calculation method is effective. The results of this study provide an option for solving the problem of a deep "blind zone" and also provide a theoretical indicator for further research.
Hansen, Tine K; Poulsen, Lars K; Stahl Skov, Per; Hefle, Susan L; Hlywka, Jason J; Taylor, Steve L; Bindslev-Jensen, Ulla; Bindslev-Jensen, Carsten
2004-12-01
Recent interest in the labeling of foods and food proteins derived from allergenic sources necessitates determination of the potential allergenicity of such food ingredients. Fish gelatin is extracted from the skin of fish species known to elicit allergic reactions in sensitized individuals. To determine the allergenicity of fish gelatin by double-blinded, placebo-controlled food challenges (DBPCFC) in clinically fish-allergic individuals. Thirty fish-allergic patients diagnosed according to the EAACI Guidelines were included (age 9-50 years). Skin prick tests (SPT) and Histamine Release tests (HR) were performed with fish gelatin and codfish, and codfish-specific IgE was measured. All patients underwent DBPCFC with a cumulative dose of 14.61 g fish gelatin. In all 30 patients SPT, HR, and specific IgE to codfish were positive. SPT and HR with fish gelatin were positive in 3/30 and 7/30, respectively. One patient showed mild reaction to placebo and no reaction to the active challenge. Two patients reported mild subjective reactions to active challenge. Upon re-challenge one of them described subjective symptoms again to the active challenge (7.61 g cumulated dose of fish gelatin) with no reaction to placebo, while the other experienced very mild subjective symptoms to placebo and nothing to the active. The proportion of truly sensitive patients was estimated to 0.03 in the total study group. None of 30 fish allergic patients reacted adversely to the ingestion of 3.61 g cumulative dose of fish gelatin. In this study fish gelatin presents no risk to fish-allergic patients at the doses typically used. Statistically, these results indicate that there is 95% certainty that 90% of fish-allergic consumers will not react to ingestion of a 3.61 g cumulative dose of fish gelatin.
Kim, Kyu Shik; Chung, Jae Hoon; Jo, Jung Ki; Kim, Jae Heon; Kim, Seungjun; Cho, Jeoung Man; Cho, Hee Ju; Choi, Hong Yong; Lee, Seung Wook
2018-07-01
Randomized controlled trials (RCTs) provide the best quality clinical evidence. The aim of this study was to assess the quality of RCTs published by the International Urogynecology Journal (IUJ) in 2007-2016. RCTs in original articles were extracted from PubMed and IUJ homepage. Change in RCT quality over time was assessed with Jadad and van Tulder scales and Cochrane Collaboration's risk of bias tool (CCRBT). Jadad scores of 3-5 or van Tulder scores of >5 indicated high-quality RCTs. The effect on RCT quality of including funding source and institutional review board (IRB) approval statements and describing the intervention was assessed. In addition, changes in RCT topics over time were assessed. Annual RCT frequencies did not change significantly (6.7-15.7%): 36.1% and 25.7% described blinding and allocation concealment, respectively. Both tended to increase between 2013 and 2016, particularly 2013 and 2014. Funding statement inclusion (39.1% overall) and intervention description (78.2% overall) tended to increase steadily. IRB statement inclusion (60.4% overall) increased significantly (p < 0.01). Jadad scores and van Tulder rose significantly until 2014 (p < 0.01). Frequencies of high-quality RCTs tended to rise. CCRBT indicated that RCTs with a low risk of bias tended to increase until 2014. However, from 2015, Jadad scores, van Tulder, and CCRBT the low risk tended to decreased. RCTs with funding and IRB approval statements had higher Jadad and van Tulder scores than unfunded RCTs (p < 0.01 and p < 0.01, respectively). Intervention description did not associate with better quality. RCT quality improved over time, but a dip in quality was observed in 2015-2016 because of decreased blinding and allocation concealment.
Zhai, Xiao; Cui, Jin; Wang, Yiran; Qu, Zhiquan; Mu, Qingchun; Li, Peiwen; Zhang, Chaochao; Yang, Mingyuan; Chen, Xiao; Chen, Ziqiang; Li, Ming
2017-03-01
To examine the risk of bias of methodological quality of reporting randomized clinical trials (RCTs) in major neurology journals before and after the update (2011) of Cochrane risk of bias tool. RCTs in 5 leading neurology journals in 2008 and 2013 were searched systematically. Characteristics were extracted based on the list of the modified Cochrane Collaboration's tool. Country, number of patients, type of intervention, and funding source also were examined for further analysis. A total of 138 RCTs were enrolled in this study. The rates of following a trial plan were 61.6% for the allocation generation, 52.9% for the allocation concealment, 84.8% for the blinding of the participants or the personnel, 34.8% for the blinding of outcome assessment, 78.3% for the incomplete outcome data, and 67.4% for the selective reporting. A significant setback was found in "the selective reporting" in 2013 than that in 2008. Trials performed by multi-centers and on a large scale had significantly more "low risk of bias" trials. Not only the number of surgical trials (5.8%) was much less than that of trials using drugs (73.9%), but also the reporting quality of surgical trials were worse (P = 0.008). Finally, only 17.4% trials met the criterion of "low risk of bias." The modified "risk of bias" tool is an improved version for assessment. Methodological quality of reporting RCTs in the 5neurology journals is unsatisfactory, especially that for surgical RCTs, and it could be further improved. Copyright © 2017 Elsevier Inc. All rights reserved.
Social internet sites as a source of public health information.
Vance, Karl; Howe, William; Dellavalle, Robert P
2009-04-01
Social media websites, such as YouTube, Facebook, MySpace, Twitter, and Second Life are rapidly emerging as popular sources of health information especially for teens and young adults. Social media marketing carries the advantages of low cost, rapid transmission through a wide community, and user interaction. Disadvantages include blind authorship, lack of source citation, and presentation of opinion as fact. Dermatologists and other health care providers should recognize the importance of social media websites and their potential usefulness for disseminating health information.
A source number estimation method for single optical fiber sensor
NASA Astrophysics Data System (ADS)
Hu, Junpeng; Huang, Zhiping; Su, Shaojing; Zhang, Yimeng; Liu, Chunwu
2015-10-01
The single-channel blind source separation (SCBSS) technique makes great significance in many fields, such as optical fiber communication, sensor detection, image processing and so on. It is a wide range application to realize blind source separation (BSS) from a single optical fiber sensor received data. The performance of many BSS algorithms and signal process methods will be worsened with inaccurate source number estimation. Many excellent algorithms have been proposed to deal with the source number estimation in array signal process which consists of multiple sensors, but they can not be applied directly to the single sensor condition. This paper presents a source number estimation method dealing with the single optical fiber sensor received data. By delay process, this paper converts the single sensor received data to multi-dimension form. And the data covariance matrix is constructed. Then the estimation algorithms used in array signal processing can be utilized. The information theoretic criteria (ITC) based methods, presented by AIC and MDL, Gerschgorin's disk estimation (GDE) are introduced to estimate the source number of the single optical fiber sensor's received signal. To improve the performance of these estimation methods at low signal noise ratio (SNR), this paper make a smooth process to the data covariance matrix. By the smooth process, the fluctuation and uncertainty of the eigenvalues of the covariance matrix are reduced. Simulation results prove that ITC base methods can not estimate the source number effectively under colored noise. The GDE method, although gets a poor performance at low SNR, but it is able to accurately estimate the number of sources with colored noise. The experiments also show that the proposed method can be applied to estimate the source number of single sensor received data.
NASA Astrophysics Data System (ADS)
Brewick, P. T.; Smyth, A. W.
2014-12-01
The accurate and reliable estimation of modal damping from output-only vibration measurements of structural systems is a continuing challenge in the fields of operational modal analysis (OMA) and system identification. In this paper a modified version of the blind source separation (BSS)-based Second-Order Blind Identification (SOBI) method was used to perform modal damping identification on a model bridge structure under varying loading conditions. The bridge model was created with finite elements and consisted of a series of stringer beams supported by a larger girder. The excitation was separated into two categories: ambient noise and traffic loads with noise modeled with random forcing vectors and traffic simulated with moving loads for cars and partially distributed moving masses for trains. The acceleration responses were treated as the mixed output signals for the BSS algorithm. The modified SOBI method used a windowing technique to maximize the amount of information used for blind identification from the responses. The modified SOBI method successfully found the mode shapes for both types of excitation with strong accuracy, but power spectral densities (PSDs) of the recovered modal responses showed signs of distortion for the traffic simulations. The distortion had an adverse affect on the damping ratio estimates for some of the modes but no correlation could be found between the accuracy of the damping estimates and the accuracy of the recovered mode shapes. The responses and their PSDs were compared to real-world collected data and patterns similar to distortion were observed implying that this issue likely affects real-world estimates.
Effects of nitrogen and carbon sources on the production of inulinase from strain Bacillus sp. SG113
NASA Astrophysics Data System (ADS)
Gavrailov, Simeon; Ivanova, Viara
2016-03-01
The effects of the carbon and nitrogen substrates on the growth of Bacillus sp. SG113 strain were studied. The use of organic nitrogen sources (peptone, beef extract, yeast extract, casein) leads to rapid cellular growth and the best results for the Bacillus strain were obtained with casein hydrolysate. From the inorganic nitrogen sources studied, the (NH4) 2SO4 proved to be the best nitrogen source. Casein hydrolysate and (NH4) 2SO4 stimulated the invertase synthesis. In the presence of Jerusalem artichoke, onion and garlic extracts as carbon sources the strain synthesized from 6 to 10 times more inulinase.
2013-01-01
Background There is little or no information available on the impact of funding by the food industry on trial outcomes and methodological quality of synbiotics, probiotics and prebiotics research in infants. The objective of this study was to compare the methodological quality, outcomes of food industry sponsored trials versus non industry sponsored trials, with regards to supplementation of synbiotics, probiotics and prebiotics in infant formula. Methods A comprehensive search was conducted to identify published and unpublished randomized clinical trials (RCTs). Cochrane methodology was used to assess the risk of bias of included RCTs in the following domains: 1) sequence generation; 2) allocation concealment; 3) blinding; 4) incomplete outcome data; 5) selective outcome reporting; and 6) other bias. Clinical outcomes and authors’ conclusions were reported in frequencies and percentages. The association between source of funding, risk of bias, clinical outcomes and conclusions were assessed using Pearson’s Chi-square test and the Fisher’s exact test. A p-value < 0.05 was statistically significant. Results Sixty seven completed and 3 on-going RCTs were included. Forty (59.7%) were funded by food industry, 11 (16.4%) by non-industry entities and 16 (23.9%) did not specify source of funding. Several risk of bias domains, especially sequence generation, allocation concealment and blinding, were not adequately reported. There was no significant association between the source of funding and sequence generation, allocation concealment, blinding and selective reporting, majority of reported clinical outcomes or authors’ conclusions. On the other hand, source of funding was significantly associated with the domains of incomplete outcome data, free of other bias domains as well as reported antibiotic use and conclusions on weight gain. Conclusion In RCTs on infants fed infant formula containing probiotics, prebiotics or synbiotics, the source of funding did not influence the majority of outcomes in favour of the sponsors’ products. More non-industry funded research is needed to further assess the impact of funding on methodological quality, reported clinical outcomes and authors’ conclusions. PMID:24219082
Analysis of Freight Transport Strategies and Methodologies
DOT National Transportation Integrated Search
2017-12-01
Transportation agencies are often blind to freight flows at the last mile level of truck movements. New strategies, data sources, and analytics have the potential to provide an empirical understanding of last mile truck movements and their impa...
Prevent Eye Damage: Protect Yourself from UV Radiation
... vision. ® Snow Blindness (Photokeratitis): A temporary but painful burn to the cornea caused by a day at the beach without sunglasses; reflections off of snow, water, or concrete; or exposure to artificial light sources such as ...
Jelicic Kadic, Antonia; Vucic, Katarina; Dosenovic, Svjetlana; Sapunar, Damir; Puljak, Livia
2016-06-01
To compare speed and accuracy of graphical data extraction using manual estimation and open source software. Data points from eligible graphs/figures published in randomized controlled trials (RCTs) from 2009 to 2014 were extracted by two authors independently, both by manual estimation and with the Plot Digitizer, open source software. Corresponding authors of each RCT were contacted up to four times via e-mail to obtain exact numbers that were used to create graphs. Accuracy of each method was compared against the source data from which the original graphs were produced. Software data extraction was significantly faster, reducing time for extraction for 47%. Percent agreement between the two raters was 51% for manual and 53.5% for software data extraction. Percent agreement between the raters and original data was 66% vs. 75% for the first rater and 69% vs. 73% for the second rater, for manual and software extraction, respectively. Data extraction from figures should be conducted using software, whereas manual estimation should be avoided. Using software for data extraction of data presented only in figures is faster and enables higher interrater reliability. Copyright © 2016 Elsevier Inc. All rights reserved.
Krzeski, T; Kazón, M; Borkowski, A; Witeska, A; Kuczera, J
1993-01-01
The 134 patients (aged 53 to 84 years) with symptoms of benign prostatic hyperplasia were drawn from two medical centers in Warsaw. The patients were randomly assigned to receive two capsules of the standard dose of an urtica/pygeum preparation (300 mg of Urtica dioica root extract combined with 25 mg of Pygeum africanum bark extract) or two capsules containing half the standard dose twice daily for 8 weeks. After 28 days' treatment, urine flow, residual urine, and nycturia were significantly reduced in both treatment groups. After 56 days' treatment, further significant decreases were found in residual urine (half-dose group) and in nycturia (both groups). There were no between-group differences in these measures of efficacy. Five patients reported adverse effects of treatment; treatment was not discontinued in any patient because of side effects. It is concluded that half doses of the urtica/pygeum extract are as safe and effective as the recommended full doses.
Harris, Matthew; Marti, Joachim; Watt, Hillary; Bhatti, Yasser; Macinko, James; Darzi, Ara W
2017-11-01
Unconscious bias may interfere with the interpretation of research from some settings, particularly from lower-income countries. Most studies of this phenomenon have relied on indirect outcomes such as article citation counts and publication rates; few have addressed or proven the effect of unconscious bias in evidence interpretation. In this randomized, blinded crossover experiment in a sample of 347 English clinicians, we demonstrate that changing the source of a research abstract from a low- to a high-income country significantly improves how it is viewed, all else being equal. Using fixed-effects models, we measured differences in ratings for strength of evidence, relevance, and likelihood of referral to a peer. Having a high-income-country source had a significant overall impact on respondents' ratings of relevance and recommendation to a peer. Unconscious bias can have far-reaching implications for the diffusion of knowledge and innovations from low-income countries.
Hunt, Sheena; Stebbings, Simon; McNamara, Debra
2016-10-28
This six-month single-centre open-label extension study, conducted at the University of Otago, Dunedin, follows from a previously published 12-week pilot double-blind randomised placebo-controlled study of dietary supplement, Arthrem® (ART) in patients with osteoarthritis (OA) of the hip or knee. The pilot double-blind study showed that treatment with ART 150 mg twice-daily was associated with clinically relevant pain reduction. The extension study aims were to assess longer-term safety and efficacy during six months' treatment following the pilot trial. Patients who completed the pilot double-blind study had the option to continue on open-label treatment with ART for a further six months. Safety was assessed by adverse event monitoring and laboratory tests at three and six months. Efficacy was assessed at three and six months using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC®). Thirty-four patients entered the optional extension and 28 completed six months' treatment. ART was well tolerated when taken for up to nine months. Improvements in WOMAC® efficacy parameters reported in the double-blind phase of the study were maintained over six months. ART appears to be a safe and effective alternative for managing the symptoms of OA over an extended period.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lew, Bartosz; Kus, Andrzej; Birkinshaw, Mark
We investigate the effectiveness of blind surveys for radio sources and galaxy cluster thermal Sunyaev-Zel'dovich effects (TSZEs) using the four-pair, beam-switched OCRA-f radiometer on the 32-m radio telescope in Poland. The predictions are based on mock maps that include the cosmic microwave background, TSZEs from hydrodynamical simulations of large scale structure formation, and unresolved radio sources. We validate the mock maps against observational data, and examine the limitations imposed by simplified physics. We estimate the effects of source clustering towards galaxy clusters from NVSS source counts around Planck-selected cluster candidates, and include appropriate correlations in our mock maps. The studymore » allows us to quantify the effects of halo line-of-sight alignments, source confusion, and telescope angular resolution on the detections of TSZEs. We perform a similar analysis for the planned 100-m Hevelius radio telescope (RTH) equipped with a 49-beam radio camera and operating at frequencies up to 22 GHz.We find that RT32/OCRA-f will be suitable for small-field blind radio source surveys, and will detect 33{sup +17}{sub −11} new radio sources brighter than 0.87 mJy at 30 GHz in a 1 deg{sup 2} field at > 5σ CL during a one-year, non-continuous, observing campaign, taking account of Polish weather conditions. It is unlikely that any galaxy cluster will be detected at 3σ CL in such a survey. A 60-deg{sup 2} survey, with field coverage of 2{sup 2} beams per pixel, at 15 GHz with the RTH, would find <1.5 galaxy clusters per year brighter than 60 μJy (at 3σ CL), and would detect about 3.4 × 10{sup 4} point sources brighter than 1 mJy at 5σ CL, with confusion causing flux density errors ∼< 2% (20%) in 68% (95%) of the detected sources.A primary goal of the planned RTH will be a wide-area (π sr) radio source survey at 15 GHz. This survey will detect nearly 3 × 10{sup 5} radio sources at 5σ CL down to 1.3 mJy, and tens of galaxy clusters, in one year of operation with typical weather conditions. Confusion will affect the measured flux densities by ∼< 1.5% (16%) for 68% (95%) of the point sources. We also gauge the impact of the RTH by investigating its performance if equipped with the existing RT32 receivers, and the performance of the RT32 equipped with the RTH radio camera.« less
El-Kholey, Khalid E
2017-03-01
The study was designed to evaluate the anesthetic efficacy of 4 % articaine with 1:100,000 epinephrine (A100) in infiltration and inferior alveolar nerve block (IANB) anesthetic techniques for the pain control during extraction of the mandibular posterior teeth. This prospective randomized single-blind clinical trial included 100 patients needing extraction of at least two mandibular molars. Patients received either infiltration in the buccal vestibule opposite to the first molar supplemented with lingual infiltration or standard IANB with A100. For assessment of depth of anesthesia obtained by the two anaethetic techniques, presence or absence of pain during the extraction were rated using the visual analog scale. Fifty patients received infiltration anesthesia and fifty patients were anesthetized by IANB. The success rate of pain-free extraction after buccal infiltration was 94 %, whereas by using IANB with the same anesthetic it was 92 %. No statistical differences were detected in the success rates between the two anesthetic techniques ( P = 0.15). Buccal Infiltration can be considered a good option during extraction of the mandibular molar and premolar teeth of course, with supplemental lingual anesthesia.
Model-based Bayesian signal extraction algorithm for peripheral nerves
NASA Astrophysics Data System (ADS)
Eggers, Thomas E.; Dweiri, Yazan M.; McCallum, Grant A.; Durand, Dominique M.
2017-10-01
Objective. Multi-channel cuff electrodes have recently been investigated for extracting fascicular-level motor commands from mixed neural recordings. Such signals could provide volitional, intuitive control over a robotic prosthesis for amputee patients. Recent work has demonstrated success in extracting these signals in acute and chronic preparations using spatial filtering techniques. These extracted signals, however, had low signal-to-noise ratios and thus limited their utility to binary classification. In this work a new algorithm is proposed which combines previous source localization approaches to create a model based method which operates in real time. Approach. To validate this algorithm, a saline benchtop setup was created to allow the precise placement of artificial sources within a cuff and interference sources outside the cuff. The artificial source was taken from five seconds of chronic neural activity to replicate realistic recordings. The proposed algorithm, hybrid Bayesian signal extraction (HBSE), is then compared to previous algorithms, beamforming and a Bayesian spatial filtering method, on this test data. An example chronic neural recording is also analyzed with all three algorithms. Main results. The proposed algorithm improved the signal to noise and signal to interference ratio of extracted test signals two to three fold, as well as increased the correlation coefficient between the original and recovered signals by 10-20%. These improvements translated to the chronic recording example and increased the calculated bit rate between the recovered signals and the recorded motor activity. Significance. HBSE significantly outperforms previous algorithms in extracting realistic neural signals, even in the presence of external noise sources. These results demonstrate the feasibility of extracting dynamic motor signals from a multi-fascicled intact nerve trunk, which in turn could extract motor command signals from an amputee for the end goal of controlling a prosthetic limb.
Apu, Apurba Sarker; Liza, Mahmuda Sultana; Jamaluddin, A T M; Howlader, Md Amran; Saha, Repon Kumer; Rizwan, Farhana; Nasrin, Nishat
2012-09-01
To investigate the bioactivities of crude n-hexane, ethyl acetate and methanol extracts of aerial part of Boerhavia diffusa Linn. (B. diffusa) and its phytochemical analysis. The identification of phytoconstituents and assay of antioxidant, thrombolytic, cytotoxic, antimicrobial activities were conducted using specific standard in vitro procedures. The results showed that the plant extracts were a rich source of phytoconstituents. Methanol extract showed higher antioxidant, thrombolytic activity and less cytotoxic activity than those of n-hexane and ethyl acetate extracts of B. diffusa. Among the bioactivities, antioxidant activity was the most notable compared to the positive control and thus could be a potential rich source of natural antioxidant. In case of antimicrobial screening, crude extracts of the plant showed remarkable antibacterial activity against tested microorganisms. All the extracts showed significant inhibitory activity against Candida albicuns, at a concentration of 1000 µg/disc. The present findings suggest that, the plant widely available in Bangladesh, could be a prominent source of medicinally important natural compounds.
Blind Spectroscopic Galaxy Surveys Using an Ultra-Wide-Band Imaging Spectrograph on AtLAST and LST
NASA Astrophysics Data System (ADS)
Kohno, Kotaro
2018-01-01
A novel approach to elucidation of cosmic star formation history is a blind search for CO and [CII] emissions using a ultra-wide-band imaging spectrograph on the future large submm telescopes like AtLAST and LST. In particular, searching for [CII] emitters in the appropriate frequency range allows us to sample those sources very efficiently for a redshift range of 3.5 to 9 (190 to 420 GHz), reaching the star-formation in the EoR. Further, spectroscopic analysis of CO in the lower frequency bands will constrain the evolution of CO luminosity functions across cosmic time. We conducted a feasibility study of ``CO/[CII] tomography'' based on a mock galaxy catalog containing 1.4 million objects drawn from the S(3) -SAX (Obreschkow et al. 2009). We find that a blind spectroscopic survey using a 50-m telescope equipped with a 100-pixel imaging spectrograph, which covers 70-370 GHz simultaneously, will be promising indeed. A survey of 2 deg(2) in 1,000 hr (on-source) will uncover > 10^5 line-emitting galaxies in total, including 10^3 [CII] emitters in the EoR (Tamura et al., in prep.). Wider surveys (10 deg^2 or wider) will also be discussed for RSD science cases.
Kishii, Y; Kawasaki, S; Kitagawa, A; Muramatsu, M; Uchida, T
2014-02-01
A compact ECR ion source has utilized for carbon radiotherapy. In order to increase beam intensity with higher electric field at the extraction electrode and be better ion supply stability for long periods, electric geometry and surface conditions of an extraction electrode have been studied. Focusing attention on black deposited substances on the extraction electrode, which were observed around the extraction electrode after long-term use, the relation between black deposited substances and the electrical insulation property is investigated. The black deposited substances were inspected for the thickness of deposit, surface roughness, structural arrangement examined using Raman spectroscopy, and characteristics of electric discharge in a test bench, which was set up to simulate the ECR ion source.
Effect of plasma rich in growth factors on alveolar osteitis
Haraji, Afshin; Lassemi, Eshagh; Motamedi, Mohammad Hosein Kalantar; Alavi, Maryam; Adibnejad, Saman
2012-01-01
Introduction: The high prevalence of dry socket or alveolar osteitis (AO) is of concern in surgical removal of third molars. The aim of the present study was to assess the preventive effect of plasma rich in growth factors (PRGF) on AO and also its effect on pain management and healing acceleration in third molar extraction sockets of high-risk patients. Materials and Methods: This split-mouth, double-blind clinical trial included 40 bilateral third molar extractions (80 sockets) with at least one identified risk factor for AO. PRGF was obtained from patient's own blood, based on manufacturer's instruction, and blindly placed in one of the two bilateral sockets (PRGF group; n = 20) of each patient. The contralateral socket was treated with a placebo (control group; n = 20). Samples were evaluated for AO and pain incidence on days 2, 3 and 4 and healing and infection on days 3 and 7. Data were analyzed in SPSS v16 using Wilcoxon test. Results: There was a significant difference in dry socket and pain incidence and healing rate between the two groups. Intensity of pain and occurrence of dry socket in the study group was lower than the controls. Also the healing rate was higher (P < 0.05) for the PRGF group. No sign of infection was seen in either group. Conclusion: The application of PRGF may significantly reduce the incidence of AO or its associated pain and may accelerate healing. The prophylactic use of PRGF following third molar extraction may be suggested especially in the patients at risk of AO. PMID:23251056
Jo, Seong Jin; Shin, Hyoseung; Paik, Seung Hwan; Na, Sun Jae; Jin, Yingji; Park, Won Seok; Kim, Su Na
2013-01-01
Background Graying of hair-a sign of aging-raises cosmetic concerns. Individuals with gray hair often look older than others their age; therefore, some dye their hair for aesthetic purposes. However, hair colorants can induce many problems including skin irritation, allergic reaction and hair-breakage. Objective This randomized, double-blind clinical trial was performed in order to examine the effects of APHG-1001, a compound including an extract from Pueraria lobata, on graying hair. Methods A total of 44 female subjects were randomly treated with either APHG-1001 or placebo twice daily for 24 weeks. Using the phototrichogram analysis, a count of newly developed gray hair was estimated. Investigator assessment and subject self-assessment were also performed in order to evaluate the efficacy of the compound. Results The mean number of newly developed gray hair at 24 weeks was 6.3/cm2 in the APHG-1001 group and 11.4/cm2 in the placebo group; the difference was statistically significant (p<0.05). However, the investigator assessment and subject self-assessment did not show any significant change in the gross appearance of hair grayness by the end of the study. No severe adverse events in either group were observed. Moreover, the incidence of adverse events did not differ between the groups. Conclusion This clinical trial revealed that APHG-1001, which contains an extract of P. lobata, could prevent the development of new gray hair without any remarkable adverse effects. Thus, it can be considered as a viable treatment option for the prevention of gray hair. PMID:23717015
Response-specifying cue for action interferes with perception of feature-sharing stimuli.
Nishimura, Akio; Yokosawa, Kazuhiko
2010-06-01
Perceiving a visual stimulus is more difficult when a to-be-executed action is compatible with that stimulus, which is known as blindness to response-compatible stimuli. The present study explored how the factors constituting the action event (i.e., response-specifying cue, response intention, and response feature) affect the occurrence of this blindness effect. The response-specifying cue varied along the horizontal and vertical dimensions, while the response buttons were arranged diagonally. Participants responded based on one dimension randomly determined in a trial-by-trial manner. The response intention varied along a single dimension, whereas the response location and the response-specifying cue varied within both vertical and horizontal dimensions simultaneously. Moreover, the compatibility between the visual stimulus and the response location and the compatibility between that stimulus and the response-specifying cue was separately determined. The blindness effect emerged exclusively based on the feature correspondence between the response-specifying cue of the action task and the visual target of the perceptual task. The size of this stimulus-stimulus (S-S) blindness effect did not differ significantly across conditions, showing no effect of response intention and response location. This finding emphasizes the effect of stimulus factors, rather than response factors, of the action event as a source of the blindness to response-compatible stimuli.
Serrano-Marugán, Isabel; Herrera, Begoña; Romero, Sara; Nogales, Ramón; Poch-Broto, Joaquín; Quintero, Javier; Ortiz, Tomás
2014-02-24
Tactile stimulation is key for the posterior brain re-organization activity and attention processes, however the impact of tactile stimulation on attention deficit disorder (ADD) in blind children remains unexplored. We carried out a study with children having or not ADD (four per group). The subjects have been exposed during six months to tactile stimulation protocol consisting in two daily sessions (morning and afternoon sessions) of 30 minutes each. We have measured the ability to detect an infrequent tactile stimulus, reaction time, latency of P300, sources of brain activity, and ADD clinical symptoms, before and after tactile training. Passive tactile stimulation significantly improves ADD clinical symptoms, particularly attention, behavior and self-control of involuntary movements and tics. In addition, tactile stimulation changes the pattern of brain activity in ADD blind children inducing activity in frontal and occipital areas, which could be associated to a compensation of the attention deficit. Passive tactile stimulation training may improve ADD clinical symptoms and can reorganize the pattern of brain activity in blind ADD children.
NASA Astrophysics Data System (ADS)
Zhou, Yan; Liu, Cheng-Hui; Pu, Yang; Cheng, Gangge; Yu, Xinguang; Zhou, Lixin; Lin, Dongmei; Zhu, Ke; Alfano, Robert R.
2017-02-01
Resonance Raman (RR) spectroscopy offers a novel Optical Biopsy method in cancer discrimination by a means of enhancement in Raman scattering. It is widely acknowledged that the RR spectrum of tissue is a superposition of spectra of various key building block molecules. In this study, the Resonance Raman (RR) spectra of human metastasis of lung cancerous and normal brain tissues excited by a visible selected wavelength at 532 nm are used to explore spectral changes caused by the tumor evolution. The potential application of RR spectra human brain metastasis of lung cancer was investigated by Blind Source Separation such as Principal Component Analysis (PCA). PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of possibly correlated variables into a set of values of linearly uncorrelated variables called principal components (PCs). The results show significant RR spectra difference between human metastasis of lung cancerous and normal brain tissues analyzed by PCA. To evaluate the efficacy of for cancer detection, a linear discriminant analysis (LDA) classifier is utilized to calculate the sensitivity, and specificity and the receiver operating characteristic (ROC) curves are used to evaluate the performance of this criterion. Excellent sensitivity of 0.97, specificity (close to 1.00) and the Area Under ROC Curve (AUC) of 0.99 values are achieved under best optimal circumstance. This research demonstrates that RR spectroscopy is effective for detecting changes of tissues due to the development of brain metastasis of lung cancer. RR spectroscopy analyzed by blind source separation may have potential to be a new armamentarium.
Comparison of seven protocols to identify fecal contamination sources using Escherichia coli
Stoeckel, D.M.; Mathes, M.V.; Hyer, K.E.; Hagedorn, C.; Kator, H.; Lukasik, J.; O'Brien, T. L.; Fenger, T.W.; Samadpour, M.; Strickler, K.M.; Wiggins, B.A.
2004-01-01
Microbial source tracking (MST) uses various approaches to classify fecal-indicator microorganisms to source hosts. Reproducibility, accuracy, and robustness of seven phenotypic and genotypic MST protocols were evaluated by use of Escherichia coli from an eight-host library of known-source isolates and a separate, blinded challenge library. In reproducibility tests, measuring each protocol's ability to reclassify blinded replicates, only one (pulsed-field gel electrophoresis; PFGE) correctly classified all test replicates to host species; three protocols classified 48-62% correctly, and the remaining three classified fewer than 25% correctly. In accuracy tests, measuring each protocol's ability to correctly classify new isolates, ribotyping with EcoRI and PvuII approached 100% correct classification but only 6% of isolates were classified; four of the other six protocols (antibiotic resistance analysis, PFGE, and two repetitive-element PCR protocols) achieved better than random accuracy rates when 30-100% of challenge isolates were classified. In robustness tests, measuring each protocol's ability to recognize isolates from nonlibrary hosts, three protocols correctly classified 33-100% of isolates as "unknown origin," whereas four protocols classified all isolates to a source category. A relevance test, summarizing interpretations for a hypothetical water sample containing 30 challenge isolates, indicated that false-positive classifications would hinder interpretations for most protocols. Study results indicate that more representation in known-source libraries and better classification accuracy would be needed before field application. Thorough reliability assessment of classification results is crucial before and during application of MST protocols.
Halaska, M; Beles, P; Gorkow, C; Sieder, C
1999-08-01
In a placebo-controlled, randomized, double-blind study the efficacy of a Vitex agnus castus extract-containing solution (VACS) was investigated in patients suffering from cyclical mastalgia. Patients had mastalgia on at least 5 days in the pre-treatment cycle. During this cycle and during treatment (3 cycles; 2 x 30 drops/day), the intensity of mastalgia was recorded once per cycle using a visual analogue scale (VAS). After one/two treatment cycles, the mean decrease in pain intensity (mm, VAS) was 21.4 mm /33.7 mm in women taking VACS (n=48) and 10.6 mm/20.3 mm with placebo (n=49). The differences of the VAS-values for VACS were significantly greater than those with placebo (p=0.018; p=0.006). After three cycles, the mean VAS-score reduction for women taking VACS was 34.3 mm, a reduction of 'borderline significance' (p=0.064) on statistical testing compared with placebo (25.7 mm). There was no difference in the frequency of adverse events between both groups (VACS: n=5; placebo : n=4). VACS appears effective and was well tolerated and further evaluation of this agent in the treatment of cyclical mastalgia is warranted.
Wade, Derick T; Makela, Petra; Robson, Philip; House, Heather; Bateman, Cynthia
2004-08-01
The objective was to determine whether a cannabis-based medicinal extract (CBME) benefits a range of symptoms due to multiple sclerosis (MS). A parallel group, double-blind, randomized, placebo-controlled study was undertaken in three centres, recruiting 160 outpatients with MS experiencing significant problems from at least one of the following: spasticity, spasms, bladder problems, tremor or pain. The interventions were oromucosal sprays of matched placebo, or whole plant CBME containing equal amounts of delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) at a dose of 2.5-120 mg of each daily, in divided doses. The primary outcome measure was a Visual Analogue Scale (VAS) score for each patient's most troublesome symptom. Additional measures included VAS scores of other symptoms, and measures of disability, cognition, mood, sleep and fatigue. Following CBME the primary symptom score reduced from mean (SE) 74.36 (11.1) to 48.89 (22.0) following CBME and from 74.31 (12.5) to 54.79 (26.3) following placebo [ns]. Spasticity VAS scores were significantly reduced by CBME (Sativex) in comparison with placebo (P =0.001). There were no significant adverse effects on cognition or mood and intoxication was generally mild.
Darbinyan, V; Kteyan, A; Panossian, A; Gabrielian, E; Wikman, G; Wagner, H
2000-10-01
The aim of this study was to investigate the effect of repeated low-dose treatment with a standardized extract SHR/5 of rhizome Rhodiola rosea L, (RRE) on fatigue during night duty among a group of 56 young, healthy physicians. The effect was measured as total mental performance calculated as Fatigue Index. The tests chosen reflect an overall level of mental fatigue, involving complex perceptive and cognitive cerebral functions, such as associative thinking, short-term memory, calculation and ability of concentration, and speed of audio-visual perception. These parameters were tested before and after night duty during three periods of two weeks each: a) a test period of one RRE/placebo tablet daily, b) a washout period and c) a third period of one placebo/RRE tablet daily, in a double-blind cross-over trial. The perceptive and cognitive cerebral functions mentioned above were investigated using 5 different tests. A statistically significant improvement in these tests was observed in the treatment group (RRE) during the first two weeks period. No side-effects were reported for either treatment noted. These results suggest that RRE can reduce general fatigue under certain stressful conditions.
Szulińska, Monika; Kręgielska-Narożna, Matylda; Świątek, Joanna; Styś, Paulina; Kuźnar-Kamińska, Barbara; Jakubowski, Hieronim; Walkowiak, Jarosław; Bogdański, Paweł
2018-06-01
Garlic exerts a range of effects relevant to human health. However, its influence on the endothelium in obese individuals remains unknown. We aimed to determine the effects of garlic extract (GE) on arterial stiffness and markers of endothelial function. Ninety-two subjects were enrolled in this study. The participants were randomly assigned to receive 400 mg of GE or placebo daily for 3 months. The arterial stiffness index (SI) and markers of endothelial function such as high-sensitivity C-reactive protein (hsCRP), cholesterol (total, LDL, HDL), triglycerides, and plasminogen activator inhibitor 1 (PAI-1), as well as total antioxidant status (TAS) were quantified at baseline and the end of study. At the end of study SI (p = 0.01), hsCRP (p < 0.001, PAI-1 (p < 0.001), LDL cholesterol (p < 0.001), and TAS (p < 0.01) were reduced in the GE-supplemented group, but not in the placebo group. This randomized, double-blind, placebo-controlled trial demonstrates that supplementation with GE favorably modifies endothelial biomarkers associated with cardiovascular risk and suggests that GE can be used to suppress chronic inflammation in obese individuals. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Jeon, Seon-Min; Kim, Ji-Eun; Shin, Su-kyung; Kwon, Eun-young; Jung, Un Ju; Baek, Nam-In; Lee, Kyung-Tae; Jeong, Tae-Sook; Chung, Hae-Gon
2013-01-01
Abstract We evaluated the effects of Brassica rapa ethanol extract (BREE) on body composition and plasma lipid profiles through a randomized, double-blind, and placebo-controlled trial in overweight subjects. Fifty-eight overweight participants (age 20–50 years, body mass index23.0–24.9) were randomly assigned to two groups and served BREE (2 g/day) or placebo (starch, 2 g/day) for 10 weeks. Body compositions, nutrients intake, plasma lipids, adipocytokines, and hepatotoxicity biomarkers were assessed in all subjects at baseline and after 10 weeks of supplementation. The plasma total cholesterol (total-C) concentration was significantly increased after 10 weeks compared to the baseline in both groups. However, BREE supplementation significantly increased the high-density lipoprotein cholesterol (HDL-C) concentration and significantly reduced the total-C/HDL-C ratio, free fatty acid, and adipsin levels after 10 weeks. No significant differences were observed in body compositions, fasting blood glucose, plasma adipocytokines except adipsin, and aspartate aminotransferase and alanine aminotransferase activities between before and after trial within groups as well as between the two groups. The supplementation of BREE partially improves plasma lipid metabolism in overweight subjects without adverse effects. PMID:23342969
Schandry, Rainer; Duschek, Stefan
2008-11-01
A number of studies have provided evidence for reduced cognitive performance due to chronically low blood pressure. The present studies explored whether these deficits can be reduced by pharmacological blood pressure elevation. Effects of the Camphor-Crataegus berry extract combination (Korodin(®)) were investigated in two studies with 40 and 48 hypotensive women based on a randomized, placebo controlled double blind design. The participants were presented with different tasks assessing performance in attention and cognition. Blood pressure was measured repeatedly during the experiment. The administration of the drug led to positive and differential effects on blood pressure and cognitive performance as compared to placebo. These effects were already visible within the time range of 2-5 min. A positive correlation between blood pressure increase and performance enhancement could be demonstrated for two of the four tasks. The results show that the application of Korodin(®) results in beneficial effects on resting blood pressure and cognitive performance. The positive association between the increase in blood pressure and cognitive enhancement suggests that blood pressure plays a causal role in the cognitive deficits in hypotension and underlines that they can be reduced through antihypotensive treatment.
Kim, Kyung-Ah; Yim, Jung-Eun
2015-09-01
Quercetin, found abundantly in onion peel, has been known to have anticholesterol, antithrombotic and insulin-sensitizing properties. Here, we investigated the effect of quercetin-rich onion peel extract (OPE) on reactive oxygen species (ROS) production and antioxidative defense in obese woman. This study was randomized, double-blind, placebo controlled study. Thirty-seven healthy obese participants were randomly assigned that eighteen subjects received red soft capsuled OPE (100 mg/d, 50 mg bis in die), while the other nineteen subjects received same capsuled placebo for 12 weeks. ROS production and superoxide dismutase (SOD) activity in plasma were determined by using ROS and SOD assay kits, respectively. Baseline characteristics of anthropometric indicators and blood metabolic profiles were not significantly different between the two groups. Compared with baseline values, OPE consumption significantly reduced waist and hip circumference. Plasma ROS level and SOD activity were decreased in both placebo and OPE groups compared with baseline values. However, plasma ROS level in OPE group was significantly lower than in placebo group while plasma SOD activity in OPE group was significantly higher than in placebo group after 12 weeks of consumption. These findings indicate that OPE consumption may exert antioxidative effect by preventing the decrease of SOD activity as well as the production of ROS in obese women.
Use of honey associated with Ananas comosus (Bromelin) in the treatment of acute irritative cough
Peixoto, Décio Medeiros; Rizzo, José Angelo; Schor, Deborah; Silva, Almerinda Rêgo; de Oliveira, Dinaldo Cavalcanti; Solé, Dirceu; Sarinho, Emanuel
2016-01-01
Abstract Objective: To evaluate the immediate improvement rate of irritative cough in patients treated with the combination of Ananas comosus extract and honey (Bromelin®) compared with the use of honey alone (placebo group). Methods: Pragmatic, double-blind, randomized, parallel-group study with children aged between 2 and 15 years, with irritative cough for at least 24hours. The double-blind assessment of cough was through the number of observed coughing episodes and intensity score for a period of 10minutes of observation. The decrease of one point in the mean total score was considered as a therapeutic effect. Results: There was a reduction in coughing episodes in both groups, as well as in the cough score after 30minutes of drug or honey administration. The change in clinical score above two points, which could indicate marked improvement, occurred in five patients in the bromelin group and only in one in the placebo group, but without significant difference. There were no adverse events. Conclusions: The immediate improvement rate of irritative cough was similar in patients treated with combination of Ananas comosus extract and honey (Bromelin®) compared with the use of honey alone (placebo group). It is possible that honey has a therapeutic effect on mucus and cough characteristics (Clinical Trials: NCT01356693). PMID:27181342
Weckwerth, G-M; Simoneti, L-F; Zupelari-Gonçalves, P; Calvo, A-M; Brozoski, D-T; Dionísio, T-J; Torres, E-A; Lauris, J-R-P; Faria, F-A-C; Santos, C-F
2017-01-01
Using a double-blinded randomized crossover design, this study aimed to evaluate acute postoperative pain management, swelling and trismus in 46 volunteers undergoing extractions of the two lower third molars, in similar positions, at two different appointments who consumed a tablet of either NE (naproxen 500 mg + esomepraz ole 20 mg) or only naproxen (500 mg) every 12 hours for 4 days. Parameters were analyzed: self-reported pain intensity using a visual analog scale (VAS) pre- and postoperative mouth opening; incidence, type and severity of adverse reactions; total quantity consumed of rescue medication; and pre- and postoperative swelling. Female volunteers reported significantly more postoperative pain at 1, 1.5, 2, 3 and 4hrs after surgery while also taking their first rescue medication at a time significantly earlier when consuming NE when compared to naproxen (3.7hrs and 6.7hrs). Conversely, no differences were found between each drug group in males. In conclusion, throughout the entire study, pain was mild after using either drug in both men and women with pain scores on average well below 40mm (VAS), although in women naproxen improved acute postoperative pain management when compared to NE.
Ali, Atif; Akhtar, Naveed
2015-07-01
Escalated sebum fabrication is seen with an unattractive look and adds to the growth of acne. We aimed to investigate the efficacy and safety of 3% Cannabis seeds extract cream on human cheek skin sebum and erythema content. For this purpose, base plus 3% Cannabis seeds extract and base (control) were prepared for single blinded and comparative study. Healthy males were instructed to apply the base plus 3% Cannabis seeds extract and base twice a day to their cheeks for 12 weeks. Adverse events were observed to determine skin irritation. Measurements for sebum and erythema content were recorded at baseline, 2nd, 4th, 6th, 8th, 10th and 12th week in a control room with Sebumeter and Mexameter. Base plus 3% Cannabis seeds extract was found to be safe in volunteers. Measurements demonstrated that skin sebum and erythema content of base plus 3% Cannabis seeds extract treated side showed significant decrease (p<0.05) compared with base treated side. Base plus 3% Cannabis seeds extract showed safety. It was well tolerated for the reduction of skin sebum and erythema content. Its improved efficacy could be suggested for treatment of acne vulgaris, seborrhea, papules and pustules to get attractive facial appearance.
Wang, T; Yang, Z; Dong, P; long, J D; He, X Z; Wang, X; Zhang, K Z; Zhang, L W
2012-06-01
The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H(-)) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H(-) beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H(-) beam current of about 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.
Development of a helicon ion source: Simulations and preliminary experiments.
Afsharmanesh, M; Habibi, M
2018-03-01
In the present context, the extraction system of a helicon ion source has been simulated and constructed. Results of the ion source commissioning at up to 20 kV are presented as well as simulations of an ion beam extraction system. Argon current of more than 200 μA at up to 20 kV is extracted and is characterized with a Faraday cup and beam profile monitoring grid. By changing different ion source parameters such as RF power, extraction voltage, and working pressure, an ion beam with current distribution exhibiting a central core has been detected. Jump transition of ion beam current emerges at the RF power near to 700 W, which reveals that the helicon mode excitation has reached this power. Furthermore, measuring the emission line intensity of Ar ii at 434.8 nm is the other way we have used for demonstrating the mode transition from inductively coupled plasma to helicon. Due to asymmetrical longitudinal power absorption of a half-helix helicon antenna, it is used for the ion source development. The modeling of the plasma part of the ion source has been carried out using a code, HELIC. Simulations are carried out by taking into account a Gaussian radial plasma density profile and for plasma densities in range of 10 18 -10 19 m -3 . Power absorption spectrum and the excited helicon mode number are obtained. Longitudinal RF power absorption for two different antenna positions is compared. Our results indicate that positioning the antenna near to the plasma electrode is desirable for the ion beam extraction. The simulation of the extraction system was performed with the ion optical code IBSimu, making it the first helicon ion source extraction designed with the code. Ion beam emittance and Twiss parameters of the ellipse emittance are calculated at different iterations and mesh sizes, and the best values of the mesh size and iteration number have been obtained for the calculations. The simulated ion beam extraction system has been evaluated using optimized parameters such as the gap distance between electrodes, electrodes aperture, and extraction voltage. The gap distance, ground electrode aperture, and extraction voltage have been changed between 3 and 9 mm, 2-6.5 mm, and 10-35 kV in the simulations, respectively.
Development of a helicon ion source: Simulations and preliminary experiments
NASA Astrophysics Data System (ADS)
Afsharmanesh, M.; Habibi, M.
2018-03-01
In the present context, the extraction system of a helicon ion source has been simulated and constructed. Results of the ion source commissioning at up to 20 kV are presented as well as simulations of an ion beam extraction system. Argon current of more than 200 μA at up to 20 kV is extracted and is characterized with a Faraday cup and beam profile monitoring grid. By changing different ion source parameters such as RF power, extraction voltage, and working pressure, an ion beam with current distribution exhibiting a central core has been detected. Jump transition of ion beam current emerges at the RF power near to 700 W, which reveals that the helicon mode excitation has reached this power. Furthermore, measuring the emission line intensity of Ar ii at 434.8 nm is the other way we have used for demonstrating the mode transition from inductively coupled plasma to helicon. Due to asymmetrical longitudinal power absorption of a half-helix helicon antenna, it is used for the ion source development. The modeling of the plasma part of the ion source has been carried out using a code, HELIC. Simulations are carried out by taking into account a Gaussian radial plasma density profile and for plasma densities in range of 1018-1019 m-3. Power absorption spectrum and the excited helicon mode number are obtained. Longitudinal RF power absorption for two different antenna positions is compared. Our results indicate that positioning the antenna near to the plasma electrode is desirable for the ion beam extraction. The simulation of the extraction system was performed with the ion optical code IBSimu, making it the first helicon ion source extraction designed with the code. Ion beam emittance and Twiss parameters of the ellipse emittance are calculated at different iterations and mesh sizes, and the best values of the mesh size and iteration number have been obtained for the calculations. The simulated ion beam extraction system has been evaluated using optimized parameters such as the gap distance between electrodes, electrodes aperture, and extraction voltage. The gap distance, ground electrode aperture, and extraction voltage have been changed between 3 and 9 mm, 2-6.5 mm, and 10-35 kV in the simulations, respectively.
Binary Code Extraction and Interface Identification for Security Applications
2009-10-02
the functions extracted during the end-to-end applications and at the bottom some additional functions extracted from the OpenSSL library. fact that as...mentioned in Section 5.1 through Section 5.3 and some additional functions that we extract from the OpenSSL library for evaluation purposes. The... OpenSSL functions, the false positives and negatives are measured by comparison with the original C source code. For the malware samples, no source is
Extract of Salacia oblonga lowers acute glycemia in patients with type 2 diabetes.
Williams, Jennifer A; Choe, Yong S; Noss, Michael J; Baumgartner, Carl J; Mustad, Vikkie A
2007-07-01
Two previous studies tested the efficacy of Salacia oblonga extract in healthy adults. This study evaluated the effect of an herbal extract of Salacia oblonga on postprandial glycemia and insulinemia in patients with type 2 diabetes after ingestion of a high-carbohydrate meal. Sixty-six patients with diabetes were studied in this randomized, double-blinded crossover study. In a fasted state, subjects consumed 1 of the following 3 meals: a standard liquid control meal, a control meal + 240 mg Salacia oblonga extract, and a control meal + 480 mg Salacia oblonga extract. Serum glucose and insulin samples were measured at baseline and at postprandial intervals up to 180 min. Both doses of the Salacia extract significantly lowered the postprandial positive area under the glucose curve (14% for the 240 mg extract and 22% for the 480 mg extract) and the adjusted peak glucose response (19% for the lower dose and 27% for the higher dose of extract) to the control meal. In addition, both doses of the herbal extract significantly decreased the postprandial insulin response, lowering both the positive area under the insulin curve and the adjusted peak insulin response (14% and 9%, respectively, for the 240 mg extract; 19% and 12%, respectively, for the 480 mg extract) in comparison with the control meal. The extract of Salacia oblonga lowers acute glycemia and insulinemia in persons with type 2 diabetes after a high-carbohydrate meal. The results from this study suggest that Salacia may be beneficial to this population for postprandial glucose control.
In-situ continuous water analyzing module
Thompson, Cyril V.; Wise, Marcus B.
1998-01-01
An in-situ continuous liquid analyzing system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectometer and the volatile components are continuously analyzed by the mass spectrometer.
Extraction of space-charge-dominated ion beams from an ECR ion source: Theory and simulation
NASA Astrophysics Data System (ADS)
Alton, G. D.; Bilheux, H.
2004-05-01
Extraction of high quality space-charge-dominated ion beams from plasma ion sources constitutes an optimization problem centered about finding an optimal concave plasma emission boundary that minimizes half-angular divergence for a given charge state, independent of the presence or lack thereof of a magnetic field in the extraction region. The curvature of the emission boundary acts to converge/diverge the low velocity beam during extraction. Beams of highest quality are extracted whenever the half-angular divergence, ω, is minimized. Under minimum half-angular divergence conditions, the plasma emission boundary has an optimum curvature and the perveance, P, current density, j+ext, and extraction gap, d, have optimum values for a given charge state, q. Optimum values for each of the independent variables (P, j+ext and d) are found to be in close agreement with those derived from elementary analytical theory for extraction with a simple two-electrode extraction system, independent of the presence of a magnetic field. The magnetic field only increases the emittances of beams through additional aberrational effects caused by increased angular divergences through coupling of the longitudinal to the transverse velocity components of particles as they pass though the mirror region of the electron cyclotron resonance (ECR) ion source. This article reviews the underlying theory of elementary extraction optics and presents results derived from simulation studies of extraction of space-charge dominated heavy-ion beams of varying mass, charge state, and intensity from an ECR ion source with emphasis on magnetic field induced effects.
Bendif, Hamdi; Adouni, Khaoula; Miara, Mohamed Djamel; Baranauskienė, Renata; Kraujalis, Paulius; Venskutonis, Petras Rimantas; Nabavi, Seyed Mohammad; Maggi, Filippo
2018-09-15
The aim of this study was to demonstrate the potential of extracts from Algerian Thymus munbyanus as a valuable source of antioxidants for use on an industrial level. To this end, a study was conducted on the composition and antioxidant activities of essential oils (EOs), pressurized liquid extracts (PLE) and supercritical fluid extracts (SFE-CO 2 ) obtained from Thymus munbyanus subsp. coloratus (TMC) and subsp. munbyanus (TMM). EOs and SFE-CO 2 extracts were analysed by GC-FID and GC×GC-TOFMS revealing significant differences. A successive extraction of the solid SFE-CO 2 residue by PLE extraction with solvents of increasing polarity such as acetone, ethanol and water, was carried out. The extracts were evaluated for total phenolic content by Folin-Ciocalteu assay, while the antioxidant power was assessed by DPPH, FRAP, and ORAC assays. SFE-CO 2 extracts were also analysed for their tocopherol content. The antioxidant activity of PLE extracts was found to be higher than that of SFE-CO 2 extracts, and this increased with solvent polarity (water > ethanol > acetone). Overall, these results support the use of T. munbyanus as a valuable source of substances to be used on an industrial level as preservative agents. Copyright © 2018 Elsevier Ltd. All rights reserved.
PWC-ICA: A Method for Stationary Ordered Blind Source Separation with Application to EEG.
Ball, Kenneth; Bigdely-Shamlo, Nima; Mullen, Tim; Robbins, Kay
2016-01-01
Independent component analysis (ICA) is a class of algorithms widely applied to separate sources in EEG data. Most ICA approaches use optimization criteria derived from temporal statistical independence and are invariant with respect to the actual ordering of individual observations. We propose a method of mapping real signals into a complex vector space that takes into account the temporal order of signals and enforces certain mixing stationarity constraints. The resulting procedure, which we call Pairwise Complex Independent Component Analysis (PWC-ICA), performs the ICA in a complex setting and then reinterprets the results in the original observation space. We examine the performance of our candidate approach relative to several existing ICA algorithms for the blind source separation (BSS) problem on both real and simulated EEG data. On simulated data, PWC-ICA is often capable of achieving a better solution to the BSS problem than AMICA, Extended Infomax, or FastICA. On real data, the dipole interpretations of the BSS solutions discovered by PWC-ICA are physically plausible, are competitive with existing ICA approaches, and may represent sources undiscovered by other ICA methods. In conjunction with this paper, the authors have released a MATLAB toolbox that performs PWC-ICA on real, vector-valued signals.
PWC-ICA: A Method for Stationary Ordered Blind Source Separation with Application to EEG
Bigdely-Shamlo, Nima; Mullen, Tim; Robbins, Kay
2016-01-01
Independent component analysis (ICA) is a class of algorithms widely applied to separate sources in EEG data. Most ICA approaches use optimization criteria derived from temporal statistical independence and are invariant with respect to the actual ordering of individual observations. We propose a method of mapping real signals into a complex vector space that takes into account the temporal order of signals and enforces certain mixing stationarity constraints. The resulting procedure, which we call Pairwise Complex Independent Component Analysis (PWC-ICA), performs the ICA in a complex setting and then reinterprets the results in the original observation space. We examine the performance of our candidate approach relative to several existing ICA algorithms for the blind source separation (BSS) problem on both real and simulated EEG data. On simulated data, PWC-ICA is often capable of achieving a better solution to the BSS problem than AMICA, Extended Infomax, or FastICA. On real data, the dipole interpretations of the BSS solutions discovered by PWC-ICA are physically plausible, are competitive with existing ICA approaches, and may represent sources undiscovered by other ICA methods. In conjunction with this paper, the authors have released a MATLAB toolbox that performs PWC-ICA on real, vector-valued signals. PMID:27340397
NASA Astrophysics Data System (ADS)
Tan, J. P.; Jahim, J. M.; Wu, T. Y.; Harun, S.; Mumtaz, T.
2016-06-01
Expensive raw materials are the driving force that leads to the shifting of the petroleum-based succinic acid production into bio-based succinic acid production by microorganisms. Cost of fermentation medium is among the main factors contributing to the total production cost of bio-succinic acid. After carbon source, nitrogen source is the second largest component of the fermentation medium, the cost of which has been overlooked for the past years. The current study aimed at replacing yeast extract- a costly nitrogen source with corn steep liquor for economical production of bio-succinic acid by Actinobacillus succinogenes 130Z. In this study, a final succinic acid concentration of 20.6 g/L was obtained from the use of corn steep liquor as the nitrogen source, which was comparable with the use of yeast extract as the nitrogen source that had a final succinate concentration of 21.4 g/l. In terms of economical wise, corn steep liquor was priced at 200 /ton, which was one fifth of the cost of yeast extract at 1000 /ton. Therefore, corn steep liquor can be considered as a potential nitrogen source in biochemical industries instead of the costly yeast extract.
Pankhurst, Louise; Macfarlane-Smith, Louissa; Buchanan, James; Anson, Luke; Davies, Kerrie; O'Connor, Lily; Ashwin, Helen; Pike, Graham; Dingle, Kate E; Peto, Timothy Ea; Wordsworth, Sarah; Walker, A Sarah; Wilcox, Mark H; Crook, Derrick W
2014-08-01
Every year approximately 5000-9000 patients are admitted to a hospital with diarrhoea, which in up to 90% of cases has a non-infectious cause. As a result, single rooms are 'blocked' by patients with non-infectious diarrhoea, while patients with infectious diarrhoea are still in open bays because of a lack of free side rooms. A rapid test for differentiating infectious from non-infectious diarrhoea could be very beneficial for patients. To evaluate MassCode multiplex polymerase chain reaction (PCR) for the simultaneous diagnosis of multiple enteropathogens directly from stool, in terms of sensitivity/specificity to detect four common important enteropathogens: Clostridium difficile, Campylobacter spp., Salmonella spp. and norovirus. A retrospective study of fixed numbers of samples positive for C. difficile (n = 200), Campylobacter spp. (n = 200), Salmonella spp. (n = 100) and norovirus (n = 200) plus samples negative for all these pathogens (n = 300). Samples were sourced from NHS microbiology laboratories in Oxford and Leeds where initial diagnostic testing was performed according to Public Health England methodology. Researchers carrying out MassCode assays were blind to this information. A questionnaire survey, examining current practice for infection control teams and microbiology laboratories managing infectious diarrhoea, was also carried out. MassCode assays were carried out at Oxford University Hospitals NHS Trust. Further multiplex assays, carried out using Luminex, were run on the same set of samples at Leeds Teaching Hospitals NHS Trust. The questionnaire was completed by various NHS trusts. Sensitivity and specificity to detect C. difficile, Campylobacter spp., Salmonella spp., and norovirus. Nucleic acids were extracted from 948 clinical samples using an optimised protocol (200 Campylobacter spp., 199 C. difficile, 60 S. enterica, 199 norovirus and 295 negative samples; some samples contained more than one pathogen). Using the MassCode assay, sensitivities for each organism compared with standard microbiological testing ranged from 43% to 94% and specificities from 95% to 98%, with particularly poor performance for S. enterica. Relatively large numbers of unexpected positives not confirmed with quantitative PCR were also observed, particularly for S. enterica, Giardia lamblia and Cryptosporidium spp. As the results indicated that S. enterica detection might provide generic challenges to other multiplex assays for gastrointestinal pathogens, the Luminex xTag(®) gastrointestinal assay was also run blinded on the same extracts (937/948 remaining) and on re-extracted samples (839/948 with sufficient material). For Campylobacter spp., C. difficile and norovirus, high sensitivities (> 92%) and specificities (> 96%) were observed. For S. enterica, on the original MassCode/Oxford extracts, Luminex sensitivity compared with standard microbiological testing was 84% [95% confidence interval (CI) 73% to 93%], but this dropped to 46% on a fresh extract, very similar to MassCode, with a corresponding increase in specificity from 92% to 99%. Overall agreement on the per-sample diagnosis compared with combined microbiology plus PCR for the main four/all pathogens was 85.6%/64.7%, 87.0%/82.9% and 89.8%/86.8% for the MassCode assay, Luminex assay/MassCode extract and Luminex assay/fresh extract, respectively. Luminex assay results from fresh extracts implied that 5% of samples did not represent infectious diarrhoea, even though enteropathogens were genuinely present. Managing infectious diarrhoea was a significant burden for infection control teams (taking 21% of their time) and better diagnostics were identified as having major potential benefits for patients. Overall, the Luminex xTag gastrointestinal panel showed similar or superior sensitivity and specificity to the MassCode assay. However, on fresh extracts, this test had low sensitivity to detect a key enteric pathogen, S. enterica; making it an unrealistic option for most microbiology laboratories. Extraction efficiency appears to be a major obstacle for nucleic acid-based tests for this organism, and possibly the whole Enterobacteriaceae family. To improve workflows in service microbiology laboratories, to reduce workload for infection control practitioners, and to improve outcomes for NHS patients, further research on deoxyribonucleic acid-based multiplex gastrointestinal diagnostics is urgently needed. The Health Technology Assessment programme of the National Institute for Health Research.
Deuterium results at the negative ion source test facility ELISE
NASA Astrophysics Data System (ADS)
Kraus, W.; Wünderlich, D.; Fantz, U.; Heinemann, B.; Bonomo, F.; Riedl, R.
2018-05-01
The ITER neutral beam system will be equipped with large radio frequency (RF) driven negative ion sources, with a cross section of 0.9 m × 1.9 m, which have to deliver extracted D- ion beams of 57 A at 1 MeV for 1 h. On the extraction from a large ion source experiment test facility, a source of half of this size is being operational since 2013. The goal of this experiment is to demonstrate a high operational reliability and to achieve the extracted current densities and beam properties required for ITER. Technical improvements of the source design and the RF system were necessary to provide reliable operation in steady state with an RF power of up to 300 kW. While in short pulses the required D- current density has almost been reached, the performance in long pulses is determined in particular in Deuterium by inhomogeneous and unstable currents of co-extracted electrons. By application of refined caesium evaporation and distribution procedures, and reduction and symmetrization of the electron currents, considerable progress has been made and up to 190 A/m2 D-, corresponding to 66% of the value required for ITER, have been extracted for 45 min.
Robust watermark technique using masking and Hermite transform.
Coronel, Sandra L Gomez; Ramírez, Boris Escalante; Mosqueda, Marco A Acevedo
2016-01-01
The following paper evaluates a watermark algorithm designed for digital images by using a perceptive mask and a normalization process, thus preventing human eye detection, as well as ensuring its robustness against common processing and geometric attacks. The Hermite transform is employed because it allows a perfect reconstruction of the image, while incorporating human visual system properties; moreover, it is based on the Gaussian functions derivates. The applied watermark represents information of the digital image proprietor. The extraction process is blind, because it does not require the original image. The following techniques were utilized in the evaluation of the algorithm: peak signal-to-noise ratio, the structural similarity index average, the normalized crossed correlation, and bit error rate. Several watermark extraction tests were performed, with against geometric and common processing attacks. It allowed us to identify how many bits in the watermark can be modified for its adequate extraction.
Neutron sources for investigations on extracted beams in Russia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aksenov, V. L.
An overview is presented of the current status and prospects for the development of neutron sources intended for investigations on extracted beams in Russia. The participation of Russia in international scientific organizations is demonstrated.
Mosuro, Adedamola L.; Ajaiyeoba, Ayotunde I.; Bekibele, Charles O.; Eniola, Michael S.; Adedokun, Babatunde A.
2012-01-01
Purpose: The aim of this study is to determine the prevalence of low vision among students attending all the schools for the blind in Oyo State, Nigeria. The study set out to determine the proportion of students with low vision/severe visual impairment after best correction, to determine the causes of the low vision, to document the associated pathologies, to determine the types of treatment and visual aid devices required, and to provide the visual aids needed to the students in the schools. Materials and Methods: All schools students for the blind in Oyo State were evaluated between August 2007 and January 2008. All the students underwent a thorough ophthalmic examination that included measurement of visual acuity, retinoscopy and subjective refraction, tests for visual aids where indicated, and a structured questionnaire was administered. Results: A total of 86 students were included in the study and the mean age was 19.4 ± 8.19 years. Twenty six (30%) were under 16 years of age. The most common cause of blindness was bilateral measles keratopathy/vitamin A deficiency (VAD) in 25 students (29.1%). The most common site affected was the cornea in 25 students (29.1%), the lens in 23 (26.7%), and the retina/optic nerve in 16 (18.6%). Preventable blindness was mainly from measles keratopathy/VAD (29.1%). Eleven students benefited from refraction and correction with visual aids; two having severe visual impairment (SVI), and nine having visual impairment (VI) after correction. Conclusion: The prevalence of low vision in the schools for the blind in Oyo State is 2.3%, while the prevalence of visual impairment is 10.5%. These results suggest that preventable and treatable ocular conditions are the source of significant childhood blindness in Oyo State. PMID:23248540
Mosuro, Adedamola L; Ajaiyeoba, Ayotunde I; Bekibele, Charles O; Eniola, Michael S; Adedokun, Babatunde A
2012-10-01
The aim of this study is to determine the prevalence of low vision among students attending all the schools for the blind in Oyo State, Nigeria. The study set out to determine the proportion of students with low vision/severe visual impairment after best correction, to determine the causes of the low vision, to document the associated pathologies, to determine the types of treatment and visual aid devices required, and to provide the visual aids needed to the students in the schools. All schools students for the blind in Oyo State were evaluated between August 2007 and January 2008. All the students underwent a thorough ophthalmic examination that included measurement of visual acuity, retinoscopy and subjective refraction, tests for visual aids where indicated, and a structured questionnaire was administered. A total of 86 students were included in the study and the mean age was 19.4 ± 8.19 years. Twenty six (30%) were under 16 years of age. The most common cause of blindness was bilateral measles keratopathy/vitamin A deficiency (VAD) in 25 students (29.1%). The most common site affected was the cornea in 25 students (29.1%), the lens in 23 (26.7%), and the retina/optic nerve in 16 (18.6%). Preventable blindness was mainly from measles keratopathy/VAD (29.1%). Eleven students benefited from refraction and correction with visual aids; two having severe visual impairment (SVI), and nine having visual impairment (VI) after correction. The prevalence of low vision in the schools for the blind in Oyo State is 2.3%, while the prevalence of visual impairment is 10.5%. These results suggest that preventable and treatable ocular conditions are the source of significant childhood blindness in Oyo State.
Levis, Alexander W; Leentjens, Albert F G; Levenson, James L; Lumley, Mark A; Thombs, Brett D
2015-12-01
Some peer reviewers may inappropriately, or coercively request that authors include references to the reviewers' own work. The objective of this study was to evaluate whether, compared to reviews for a journal with single-blind peer review, reviews for a journal with open peer review included (1) fewer self-citations; (2) a lower proportion of self-citations without a rationale; and (3) a lower ratio of proportions of citations without a rationale in self-citations versus citations to others' work. Peer reviews for published manuscripts submitted in 2012 to a single-blind peer review journal, the Journal of Psychosomatic Research, were previously evaluated (Thombs et al., 2015). These were compared to publically available peer reviews of manuscripts published in 2012 in an open review journal, BMC Psychiatry. Two investigators independently extracted data for both journals. There were no significant differences between journals in the proportion of all reviewer citations that were self-citations (Journal of Psychosomatic Research: 71/225, 32%; BMC Psychiatry: 90/315, 29%; p=.50), or in the proportion of self-citations without a rationale (Journal of Psychosomatic Research: 15/71, 21%; BMC Psychiatry: 12/90, 13%; p=.21). There was no significant difference between journals in the proportion of self-citations versus citations to others' work without a rationale (p=.31). Blind and open peer review methodologies have distinct advantages and disadvantages. The present study found that, in reasonably similar journals that use single-blind and open review, there were no substantive differences in the pattern of peer reviewer self-citations. Copyright © 2015 Elsevier Inc. All rights reserved.
America: Globally Blind, Deaf, and Dumb.
ERIC Educational Resources Information Center
Lurie, Joseph
1982-01-01
From many sources comes evidence of the United States's disadvantage in international relations, through ignorance of other cultures and languages. Problems include incompetence in foreign languages, with implications for national security; inadequate understanding of world affairs; declines in government-supported international exchange; and…
Fedder, Maja D. K.; Jakobsen, Henrik B.; Giversen, Ina; Christensen, Lars P.; Parner, Erik T.; Fedder, Jens
2014-01-01
Pomegranate fruit (Punica granatum) and galangal (Alpinia galanga) have separately been shown to stimulate spermatogenesis and to increase sperm counts and motility in rodents. Within traditional medicine, pomegranate fruit has long been used to increase fertility, however studies on the effect on spermatogenesis in humans have never been published. With this study we investigated whether oral intake of tablets containing standardised amounts of extract of pomegranate fruit and powder of greater galangal rhizome (Punalpin) would increase the total number of motile spermatozoa. The study was designed as a prospective, randomized, controlled, double-blinded trial. Enrolment was based on the mean total number of motile spermatozoa of two ejaculates. The participants delivered an ejaculate after 4–8 days of tablet intake and two ejaculates just before they stopped taking the tablets. Seventy adult men with a semen quality not meeting the standards for commercial application at Nordic Cryobank, but without azoospermia, were included in the study. Participants were randomized to take tablets containing extract of pomegranate fruit (standardised with respect to punicalagin A+B, punicalin and ellagic acid) and freeze-dried rhizome of greater galangal (standardised with respect to 1′S-1′-acetoxychavicol acetate) or placebo on a daily basis for three months. Sixty-six participants completed the intervention (active treatment: n = 34; placebo: n = 32). After the intervention the total number of motile spermatozoa was increased in participants treated with plant extracts compared with the placebo group (p = 0.026). After three months of active treatment, the average total number of motile sperm increased by 62% (from 23.4 to 37.8 millions), while for the placebo group, the number of motile sperm increased by 20%. Sperm morphology was not affected by the treatment. Our findings may help subfertile men to gain an improved amount of motile ejaculated sperm by taking tablets containing preparations of pomegranate fruit extract and rhizome of greater galangal. Trial Registration ClinicalTrials.gov NCT01357044 PMID:25275520
Demarin, Vida; Bašić Kes, Vanja; Trkanjec, Zlatko; Budišić, Mislav; Bošnjak Pašić, Marija; Črnac, Petra; Budinčević, Hrvoje
2017-01-01
Objectives The aim of this randomized, double-blind, placebo-controlled trial was to determine the efficacy and safety of Ginkgo biloba extract in patients diagnosed with vascular cognitive impairment (VCI). Methods A total of 90 patients (aged 67.1±8.0 years; 59 women) were randomly allocated (1:1:1) to receive G. biloba 120 mg, G. biloba 60 mg, or placebo during a 6-month period. Assessment was made for efficacy indicators, including neuropsychological tests scores (Sandoz Clinical Assessment Geriatric Scale, Folstein Mini-Mental State Examination, Mattis Dementia Rating Scale, and Clinical Global Impression) and transcranial Doppler ultrasound findings. Safety indicators included laboratory findings, reported adverse reactions, and clinical examination. Results At the end of 6-month study period, G. biloba 120 and 60 mg showed a statistically significant positive effect in comparison with placebo only on the Clinical Global Impression score (2.6±0.8 vs 3.1±0.7 vs 2.8±0.7, respectively; P=0.038). The Clinical Global Impression score showed a significant deterioration from the baseline values in the placebo group (−0.3±0.5; P=0.021) as opposed to G. biloba groups. No significant differences were found in the transcranial Doppler ultrasound findings. Adverse reactions were significantly more common and serious in the placebo group (16 subjects) than in either of the two G. biloba extract groups (eight and nine subjects, respectively), whereas laboratory findings and clinical examinations revealed no differences between the groups receiving G. biloba extract and placebo. Conclusion According to our results, G. biloba seemed to slow down the cognitive deterioration in patients with VCI, but the effect was shown in only one of the four neuropsychological tests administered. However, because of this mild effect in combination with a few adverse reactions, we cannot say that it is ineffective or unsafe either. Further studies are still needed to provide unambiguous evidence on the efficacy and safety of G. biloba extract. PMID:28243101
Kasture, Prabhu Nagnathappa; Nagabhushan, K H; Kumar, Arun
2016-06-01
Dengue is a rapidly expanding global health problem. Approximately 2.5 billion people live in dengue-risk regions with about 100 million new cases each year worldwide. The cumulative dengue diseases burden has attained an unprecedented proportion in recent times with sharp increase in the size of human population at risk. The management of dengue virus infection is essentially supportive and symptomatic and no specific treatment is available for increasing the fallen platelets, which have a significant role in causing the mortality of dengue patient.This study was conducted to evaluate the platelet increasing efficacy of Carica papaya leaf extract (CPLE) in patients with dengue fever (DF). The administration of Carica papaya leaf extract should significantly increase the platelet count in cases of thrombocytopenia associated with dengue, preventing the patient to go in DHF or DSS conditions. A Multi-centric, Double blind, Placebo controlled, Randomized, prospective study was conducted in 300 patients across 5 centres', to evaluate the Efficacy and Safety of Carica Papaya Leaf Extract, as empirical therapy for thrombocytopenia associated with dengue fever. The subjects were randomized into two groups, as control and intervention group. Both the groups were managed by the standard management guidelines for dengue except steroid administration. In addition to this, the intervention group received CPLE tablet three times daily for five days. All of them were followed daily with platelet monitoring. This study has been registered in the clinical trial registry-India (CTRI Registration number: CTRI/2015/05/005806). The results indicate that CPLE had significant increase(p< 0.01) in the platelet count over the therapy duration, in dengue fever patients, confirming CPLE accelerates the increase in platelet count compared to the control group. There were few adverse events related to GI disturbance like nausea and vomiting which were similar in both groups. Thus this study concluded that Carica papaya leaf extract (CPLE) does significantly increase the platelet count in patients with thrombocytopenia associated with dengue with fewer side effects and good tolerability.
Hassani, Soghra; Alipour, Abbas; Darvishi Khezri, Hadi; Firouzian, Abolfazl; Emami Zeydi, Amir; Gholipour Baradari, Afshin; Ghafari, Rahman; Habibi, Wali-Allah; Tahmasebi, Homeyra; Alipour, Fatemeh; Ebrahim Zadeh, Pooneh
2015-03-01
We hypothesized that valerian root might prevent cognitive dysfunction in coronary artery bypass graft (CABG) surgery patients through stimulating serotonin receptors and anti-inflammatory activity. The aim of this study was to evaluate the effect of Valeriana officinalis root extract on prevention of early postoperative cognitive dysfunction after on-pump CABG surgery. In a randomized, double-blind, placebo-controlled trial, 61 patients, aged between 30 and 70 years, scheduled for elective CABG surgery using cardiopulmonary bypass (CPB), were recruited into the study. Patients were randomly divided into two groups who received either one valerian capsule containing 530 mg of valerian root extract (1,060 mg/daily) or placebo capsule each 12 h for 8 weeks, respectively. For all patients, cognitive brain function was evaluated before the surgery and at 10-day and 2-month follow-up by Mini Mental State Examination (MMSE) test. Mean MMSE score decreased from 27.03 ± 2.02 in the preoperative period to 26.52 ± 1.82 at the 10th day and then increased to 27.45 ± 1.36 at the 60th day in the valerian group. Conversely, its variation was reduced significantly after 60 days in the placebo group, 27.37 ± 1.87 at the baseline to 24 ± 1.91 at the 10th day, and consequently slightly increased to 24.83 ± 1.66 at the 60th day. Valerian prophylaxis reduced odds of cognitive dysfunction compared to placebo group (OR = 0.108, 95 % CI 0.022-0.545). We concluded that, based on this study, the cognitive state of patients in the valerian group was better than that in the placebo group after CABG; therefore, it seems that the use of V. officinalis root extract may prevent early postoperative cognitive dysfunction after on-pump CABG surgery.
Vaney, C; Heinzel-Gutenbrunner, M; Jobin, P; Tschopp, F; Gattlen, B; Hagen, U; Schnelle, M; Reif, M
2004-08-01
Cannabis may alleviate some symptoms associated with multiple sclerosis (MS). This study investigated the effect of an orally administered standardized Cannabis sativa plant extract in MS patients with poorly controlled spasticity. During their inpatient rehabilitation programme, 57 patients were enrolled in a prospective, randomized, double-blind, placebo-controlled crossover study of cannabis-extract capsules standardized to 2.5 mg tetrahydrocannabinol (THC) and 0.9 mg cannabidiol (CBD) each. Patients in group A started with a drug escalation phase from 15 to maximally 30 mg THC by 5 mg per day if well tolerated, being on active medication for 14 days before starting placebo. Patients in group B started with placebo for seven days, crossed to the active period (14 days) and closed with a three-day placebo period (active drug dose escalation and placebo sham escalation as in group A). Measures used included daily self-report of spasm frequency and symptoms, Ashworth Scale, Rivermead Mobility Index, 10-m timed walk, nine-hole peg test, paced auditory serial addition test (PASAT), and the digit span test. In the 50 patients included into the intention-to-treat analysis set, there were no statistically significant differences associated with active treatment compared to placebo, but trends in favour of active treatment were seen for spasm frequency, mobility and getting to sleep. In the 37 patients (per-protocol set) who received at least 90% of their prescribed dose, improvements in spasm frequency (P = 0.013) and mobility after excluding a patient who fell and stopped walking were seen (P = 0.01). Minor adverse events were slightly more frequent and severe during active treatment, and toxicity symptoms, which were generally mild, were more pronounced in the active phase. A standardized Cannabis sativa plant extract might lower spasm frequency and increase mobility with tolerable side effects in MS patients with persistent spasticity not responding to other drugs.
Bello, Segun; Moustgaard, Helene; Hróbjartsson, Asbjørn
2014-10-01
To assess the proportion of clinical trials explicitly reporting the risk of unblinding, to evaluate the completeness of reporting on unblinding risk, and to describe the reported procedures involved in assessing unblinding. We sampled at random 300 blinded randomized clinical trials indexed in PubMed in 2010. Two authors read the trial publications and extracted data independently. Twenty-four trial publications, or 8% (95% confidence interval [CI], 5, 12%), explicitly reported the risk of unblinding, of which 16 publications, or 5% (95% CI, 3, 8%), reported compromised blinding; and 8 publications, or 3% (95% CI, 1, 5%), intact blinding. The reporting on risk of unblinding in the 24 trial publications was generally incomplete. The median proportion of assessments per trial affected by unblinding was 3% (range 1-30%). The most common mechanism for unblinding was perceptible physical properties of the treatments, for example, a difference in the taste and odor of a typhoid vaccine compared with its placebo. Published articles on randomized clinical trials infrequently reported risk of unblinding. This may reflect a tendency for avoiding reporting actual or suspected unblinding or a genuine low risk of unblinding. Copyright © 2014 Elsevier Inc. All rights reserved.
Floating-point scaling technique for sources separation automatic gain control
NASA Astrophysics Data System (ADS)
Fermas, A.; Belouchrani, A.; Ait-Mohamed, O.
2012-07-01
Based on the floating-point representation and taking advantage of scaling factor indetermination in blind source separation (BSS) processing, we propose a scaling technique applied to the separation matrix, to avoid the saturation or the weakness in the recovered source signals. This technique performs an automatic gain control in an on-line BSS environment. We demonstrate the effectiveness of this technique by using the implementation of a division-free BSS algorithm with two inputs, two outputs. The proposed technique is computationally cheaper and efficient for a hardware implementation compared to the Euclidean normalisation.
The negative hydrogen Penning ion gauge ion source for KIRAMS-13 cyclotron
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, D. H.; Jung, I. S.; Kang, J.
2008-02-15
The cold-cathode-type Penning ion gauge (PIG) ion source for the internal ion source of KIRAMS-13 cyclotron has been used for generation of negative hydrogen ions. The dc H-beam current of 650 {mu}A from the PIG ion source with the Dee voltage of 40 kV and arc current of 1.0 A is extrapolated from the measured dc extraction beam currents at the low extraction dc voltages. The output optimization of PIG ion source in the cyclotron has been carried out by using various chimneys with different sizes of the expansion gap between the plasma boundary and the chimney wall. This papermore » presents the results of the dc H-extraction measurement and the expansion gap experiment.« less
NASA Astrophysics Data System (ADS)
Neri, L.; Celona, L.; Gammino, S.; Miraglia, A.; Leonardi, O.; Castro, G.; Torrisi, G.; Mascali, D.; Mazzaglia, M.; Allegra, L.; Amato, A.; Calabrese, G.; Caruso, A.; Chines, F.; Gallo, G.; Longhitano, A.; Manno, G.; Marletta, S.; Maugeri, A.; Passarello, S.; Pastore, G.; Seminara, A.; Spartà, A.; Vinciguerra, S.
2017-07-01
At the Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali del Sud (INFN-LNS) the beam commissioning of the high intensity Proton Source for the European Spallation Source (PS-ESS) started in November 2016. Beam stability at high current intensity is one of the most important parameter for the first steps of the ongoing commissioning. Promising results were obtained since the first source start with a 6 mm diameter extraction hole. The increase of the extraction hole to 8 mm allowed improving PS-ESS performances and obtaining the values required by the ESS accelerator. In this work, extracted beam current characteristics together with Doppler shift and emittance measurements are presented, as well as the description of the next phases before the installation at ESS in Lund.
Apu, Apurba Sarker; Liza, Mahmuda Sultana; Jamaluddin, A.T.M.; Howlader, Md. Amran; Saha, Repon Kumer; Rizwan, Farhana; Nasrin, Nishat
2012-01-01
Objective To investigate the bioactivities of crude n-hexane, ethyl acetate and methanol extracts of aerial part of Boerhavia diffusa Linn. (B. diffusa) and its phytochemical analysis. Methods The identification of phytoconstituents and assay of antioxidant, thrombolytic, cytotoxic, antimicrobial activities were conducted using specific standard in vitro procedures. Results The results showed that the plant extracts were a rich source of phytoconstituents. Methanol extract showed higher antioxidant, thrombolytic activity and less cytotoxic activity than those of n-hexane and ethyl acetate extracts of B. diffusa. Among the bioactivities, antioxidant activity was the most notable compared to the positive control and thus could be a potential rich source of natural antioxidant. In case of antimicrobial screening, crude extracts of the plant showed remarkable antibacterial activity against tested microorganisms. All the extracts showed significant inhibitory activity against Candida albicuns, at a concentration of 1000 µg/disc. Conclusions The present findings suggest that, the plant widely available in Bangladesh, could be a prominent source of medicinally important natural compounds. PMID:23569993
Sohrabpour, Abbas; Ye, Shuai; Worrell, Gregory A.; Zhang, Wenbo
2016-01-01
Objective Combined source imaging techniques and directional connectivity analysis can provide useful information about the underlying brain networks in a non-invasive fashion. Source imaging techniques have been used successfully to either determine the source of activity or to extract source time-courses for Granger causality analysis, previously. In this work, we utilize source imaging algorithms to both find the network nodes (regions of interest) and then extract the activation time series for further Granger causality analysis. The aim of this work is to find network nodes objectively from noninvasive electromagnetic signals, extract activation time-courses and apply Granger analysis on the extracted series to study brain networks under realistic conditions. Methods Source imaging methods are used to identify network nodes and extract time-courses and then Granger causality analysis is applied to delineate the directional functional connectivity of underlying brain networks. Computer simulations studies where the underlying network (nodes and connectivity pattern) is known were performed; additionally, this approach has been evaluated in partial epilepsy patients to study epilepsy networks from inter-ictal and ictal signals recorded by EEG and/or MEG. Results Localization errors of network nodes are less than 5 mm and normalized connectivity errors of ~20% in estimating underlying brain networks in simulation studies. Additionally, two focal epilepsy patients were studied and the identified nodes driving the epileptic network were concordant with clinical findings from intracranial recordings or surgical resection. Conclusion Our study indicates that combined source imaging algorithms with Granger causality analysis can identify underlying networks precisely (both in terms of network nodes location and internodal connectivity). Significance The combined source imaging and Granger analysis technique is an effective tool for studying normal or pathological brain conditions. PMID:27740473
Sohrabpour, Abbas; Ye, Shuai; Worrell, Gregory A; Zhang, Wenbo; He, Bin
2016-12-01
Combined source-imaging techniques and directional connectivity analysis can provide useful information about the underlying brain networks in a noninvasive fashion. Source-imaging techniques have been used successfully to either determine the source of activity or to extract source time-courses for Granger causality analysis, previously. In this work, we utilize source-imaging algorithms to both find the network nodes [regions of interest (ROI)] and then extract the activation time series for further Granger causality analysis. The aim of this work is to find network nodes objectively from noninvasive electromagnetic signals, extract activation time-courses, and apply Granger analysis on the extracted series to study brain networks under realistic conditions. Source-imaging methods are used to identify network nodes and extract time-courses and then Granger causality analysis is applied to delineate the directional functional connectivity of underlying brain networks. Computer simulations studies where the underlying network (nodes and connectivity pattern) is known were performed; additionally, this approach has been evaluated in partial epilepsy patients to study epilepsy networks from interictal and ictal signals recorded by EEG and/or Magnetoencephalography (MEG). Localization errors of network nodes are less than 5 mm and normalized connectivity errors of ∼20% in estimating underlying brain networks in simulation studies. Additionally, two focal epilepsy patients were studied and the identified nodes driving the epileptic network were concordant with clinical findings from intracranial recordings or surgical resection. Our study indicates that combined source-imaging algorithms with Granger causality analysis can identify underlying networks precisely (both in terms of network nodes location and internodal connectivity). The combined source imaging and Granger analysis technique is an effective tool for studying normal or pathological brain conditions.
NASA Astrophysics Data System (ADS)
Liu, Kai; Liu, Yuan; Liu, Yu-Rong; En, Yun-Fei; Li, Bin
2017-07-01
Channel mobility in the p-type polycrystalline silicon thin film transistors (poly-Si TFTs) is extracted using Hoffman method, linear region transconductance method and multi-frequency C-V method. Due to the non-negligible errors when neglecting the dependence of gate-source voltage on the effective mobility, the extracted mobility results are overestimated using linear region transconductance method and Hoffman method, especially in the lower gate-source voltage region. By considering of the distribution of localized states in the band-gap, the frequency independent capacitance due to localized charges in the sub-gap states and due to channel free electron charges in the conduction band were extracted using multi-frequency C-V method. Therefore, channel mobility was extracted accurately based on the charge transport theory. In addition, the effect of electrical field dependent mobility degradation was also considered in the higher gate-source voltage region. In the end, the extracted mobility results in the poly-Si TFTs using these three methods are compared and analyzed.
Majid, Omer Waleed; Ahmed, Aws Mahmood
2018-04-01
The purpose of the present study was to evaluate the anesthetic adequacy of 4% articaine 1.8 mL versus 2% lidocaine 3.6 mL without palatal injection compared with the standard technique for the extraction of maxillary molar teeth. This randomized, double-blinded, placebo-controlled clinical trial included patients requiring extraction of 1 maxillary molar under local anesthesia. Patients were randomly distributed into 1 of 3 groups: group A received 4% articaine 1.8 mL as a buccal injection and 0.2 mL as a palatal injection, group B received 4% articaine 1.8 mL plus normal saline 0.2 mL as a palatal injection, and group C received 2% lidocaine 3.6 mL plus normal saline 0.2 mL as a palatal injection. Pain was measured during injection, 8 minutes afterward, and during extraction using a visual analog scale. Initial palatal anesthesia and patients' satisfaction were measured using a 5-score verbal rating scale. Statistical analyses included descriptive statistics, analysis of variance, and Pearson χ 2 test. Differences with a P value less than .05 were considered significant. Eighty-four patients were included in the study. The average pain of injection was comparable among all study groups (P = .933). Pain during extraction in the articaine group was significantly less than that experienced in the placebo groups (P < .001), although the differences between placebo groups were insignificant. Satisfaction scores were significantly higher in the articaine group compared with the placebo groups (P < .001), with comparable results between placebo groups. Although the anesthetic effects of single placebo-controlled buccal injections of 4% articaine and 2% lidocaine were comparable, the level of anesthetic adequacy was statistically less than that achieved by 4% articaine given by the standard technique. These results do not justify the buccal and non-palatal infiltration of articaine or lidocaine as an effective alternative to the standard technique in the extraction of maxillary molar teeth. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
40 CFR 439.21 - Special definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... STANDARDS PHARMACEUTICAL MANUFACTURING POINT SOURCE CATEGORY Extraction Products § 439.21 Special definitions. For the purpose of this subpart: (a) Extraction means process operations that derive pharmaceutically active ingredients from natural sources such as plant roots and leaves, animal glands, and...
40 CFR 439.21 - Special definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... STANDARDS PHARMACEUTICAL MANUFACTURING POINT SOURCE CATEGORY Extraction Products § 439.21 Special definitions. For the purpose of this subpart: (a) Extraction means process operations that derive pharmaceutically active ingredients from natural sources such as plant roots and leaves, animal glands, and...
Mizuno, Yuya; Suzuki, Takefumi; Nakagawa, Atsuo; Yoshida, Kazunari; Mimura, Masaru; Fleischhacker, Walter Wolfgang; Uchida, Hiroyuki
2014-01-01
Background: Antipsychotic-induced metabolic adversities are often difficult to manage. Using concomitant medications to counteract these adversities may be a rational option. Objective: To systematically determine the effectiveness of medications to counteract antipsychotic-induced metabolic adversities in patients with schizophrenia. Data Sources: Published articles until November 2013 were searched using 5 electronic databases. Clinical trial registries were searched for unpublished trials. Study Selection: Double-blind randomized placebo-controlled trials focusing on patients with schizophrenia were included if they evaluated the effects of concomitant medications on antipsychotic-induced metabolic adversities as a primary outcome. Data Extraction: Variables relating to participants, interventions, comparisons, outcomes, and study design were extracted. The primary outcome was change in body weight. Secondary outcomes included clinically relevant weight change, fasting glucose, hemoglobin A1c, fasting insulin, insulin resistance, cholesterol, and triglycerides. Data Synthesis: Forty trials representing 19 unique interventions were included in this meta-analysis. Metformin was the most extensively studied drug in regard to body weight, the mean difference amounting to −3.17 kg (95% CI: −4.44 to −1.90 kg) compared to placebo. Pooled effects for topiramate, sibutramine, aripiprazole, and reboxetine were also different from placebo. Furthermore, metformin and rosiglitazone improved insulin resistance, while aripiprazole, metformin, and sibutramine decreased blood lipids. Conclusion: When nonpharmacological strategies alone are insufficient, and switching antipsychotics to relatively weight-neutral agents is not feasible, the literature supports the use of concomitant metformin as first choice among pharmacological interventions to counteract antipsychotic-induced weight gain and other metabolic adversities in schizophrenia. PMID:24636967
Pittler, Max H; Verster, Joris C; Ernst, Edzard
2005-01-01
Objective To assess the clinical evidence on the effectiveness of any medical intervention for preventing or treating alcohol hangover. Data sources Systematic searches on Medline, Embase, Amed, Cochrane Central, the National Research Register (UK), and ClincalTrials.gov (USA); hand searches of conference proceedings and bibliographies; contact with experts and manufacturers of commercial preparations. Language of publication was not restricted. Study selection and data extraction All randomised controlled trials of any medical intervention for preventing or treating alcohol hangover were included. Trials were considered if they were placebo controlled or controlled against a comparator intervention. Titles and abstracts of identified articles were read and hard copies were obtained. The selection of studies, data extraction, and validation were done independently by two reviewers. The Jadad score was used to evaluate methodological quality. Results Fifteen potentially relevant trials were identified. Seven publications failed to meet all inclusion criteria. Eight randomised controlled trials assessing eight different interventions were reviewed. The agents tested were propranolol, tropisetron, tolfenamic acid, fructose or glucose, and the dietary supplements Borago officinalis (borage), Cynara scolymus (artichoke), Opuntia ficus-indica (prickly pear), and a yeast based preparation. All studies were double blind. Significant intergroup differences for overall symptom scores and individual symptoms were reported only for tolfenamic acid, γ linolenic acid from B officinalis, and a yeast based preparation. Conclusion No compelling evidence exists to suggest that any conventional or complementary intervention is effective for preventing or treating alcohol hangover. The most effective way to avoid the symptoms of alcohol induced hangover is to practise abstinence or moderation. PMID:16373736
Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toivanen, V., E-mail: ville.aleksi.toivanen@cern.ch; Küchler, D.
2016-02-15
The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a waymore » to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.« less
Toivanen, V; Küchler, D
2016-02-01
The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sidorov, A.; Dorf, M.; Zorin, V.
2008-02-15
Electron cyclotron resonance ion source with quasi-gas-dynamic regime of plasma confinement (ReGIS), constructed at the Institute of Applied Physics, Russia, provides opportunities for extracting intense and high-brightness multicharged ion beams. Despite the short plasma lifetime in a magnetic trap of a ReGIS, the degree of multiple ionization may be significantly enhanced by the increase in power and frequency of the applied microwave radiation. The present work is focused on studying the intense beam quality of this source by the pepper-pot method. A single beamlet emittance measured by the pepper-pot method was found to be {approx}70 {pi} mm mrad, and themore » total extracted beam current obtained at 14 kV extraction voltage was {approx}25 mA. The results of the numerical simulations of ion beam extraction are found to be in good agreement with experimental data.« less
Moderate pressure plasma source of nonthermal electrons
NASA Astrophysics Data System (ADS)
Gershman, S.; Raitses, Y.
2018-06-01
Plasma sources of electrons offer control of gas and surface chemistry without the need for complex vacuum systems. The plasma electron source presented here is based on a cold cathode glow discharge (GD) operating in a dc steady state mode in a moderate pressure range of 2–10 torr. Ion-induced secondary electron emission is the source of electrons accelerated to high energies in the cathode sheath potential. The source geometry is a key to the availability and the extraction of the nonthermal portion of the electron population. The source consists of a flat and a cylindrical electrode, 1 mm apart. Our estimates show that the length of the cathode sheath in the plasma source is commensurate (~0.5–1 mm) with the inter-electrode distance so the GD operates in an obstructed regime without a positive column. Estimations of the electron energy relaxation confirm the non-local nature of this GD, hence the nonthermal portion of the electron population is available for extraction outside of the source. The use of a cylindrical anode presents a simple and promising method of extracting the high energy portion of the electron population. Langmuir probe measurements and optical emission spectroscopy confirm the presence of electrons with energies ~15 eV outside of the source. These electrons become available for surface modification and radical production outside of the source. The extraction of the electrons of specific energies by varying the anode geometry opens exciting opportunities for future exploration.
Earthquake Source Inversion Blindtest: Initial Results and Further Developments
NASA Astrophysics Data System (ADS)
Mai, P.; Burjanek, J.; Delouis, B.; Festa, G.; Francois-Holden, C.; Monelli, D.; Uchide, T.; Zahradnik, J.
2007-12-01
Images of earthquake ruptures, obtained from modelling/inverting seismic and/or geodetic data exhibit a high degree in spatial complexity. This earthquake source heterogeneity controls seismic radiation, and is determined by the details of the dynamic rupture process. In turn, such rupture models are used for studying source dynamics and for ground-motion prediction. But how reliable and trustworthy are these earthquake source inversions? Rupture models for a given earthquake, obtained by different research teams, often display striking disparities (see http://www.seismo.ethz.ch/srcmod) However, well resolved, robust, and hence reliable source-rupture models are an integral part to better understand earthquake source physics and to improve seismic hazard assessment. Therefore it is timely to conduct a large-scale validation exercise for comparing the methods, parameterization and data-handling in earthquake source inversions.We recently started a blind test in which several research groups derive a kinematic rupture model from synthetic seismograms calculated for an input model unknown to the source modelers. The first results, for an input rupture model with heterogeneous slip but constant rise time and rupture velocity, reveal large differences between the input and inverted model in some cases, while a few studies achieve high correlation between the input and inferred model. Here we report on the statistical assessment of the set of inverted rupture models to quantitatively investigate their degree of (dis-)similarity. We briefly discuss the different inversion approaches, their possible strength and weaknesses, and the use of appropriate misfit criteria. Finally we present new blind-test models, with increasing source complexity and ambient noise on the synthetics. The goal is to attract a large group of source modelers to join this source-inversion blindtest in order to conduct a large-scale validation exercise to rigorously asses the performance and reliability of current inversion methods and to discuss future developments.
Attah, Simon K; Ayeh-Kumi, Patrick F; Sittie, Archibald A; Oppong, Isaac V; Nyarko, Alexander K
2013-03-18
Onchocerciasis transmitted by Onchocerca volvulus is the second major cause of blindness in the world and it impacts negatively on the socio-economic development of the communities affected. Currently, ivermectin, a microfilaricidal drug is the only drug recommended for treating this disease. There have been speculations, of late, concerning O. volvulus resistance to ivermectin. Owing to this, it has become imperative to search for new drugs. World-wide, ethnomedicines including extracts of Euphorbia hirta and Rauvolfia vomitoria are used for treating various diseases, both infectious and non-infectious. In this study extracts of the two plants were evaluated in vitro in order to determine their effect against O. volvulus microfilariae. The toxicity of the E. hirta extracts on monkey kidney cell (LLCMK2) lines was also determined. The investigations showed that extracts of both plants immobilised microfilariae at different levels in vitro and, therefore, possess antifilarial properties. It was found that all the E. hirta extracts with the exception of the hexane extracts were more effective than those of R. vomitoria. Among the extracts of E. hirta the ethyl acetate fraction was most effective, and comparable to that of dimethanesulphonate salt but higher than that of Melarsoprol (Mel B). However, the crude ethanolic extract of E. hirta was found to be the least toxic to the LLCMK2 compared to the fractionated forms. Extracts from both plants possess antifilarial properties; however, the crude extract of E. hirta was found to be least toxic to LLCMK2.
2013-01-01
Background Onchocerciasis transmitted by Onchocerca volvulus is the second major cause of blindness in the world and it impacts negatively on the socio-economic development of the communities affected. Currently, ivermectin, a microfilaricidal drug is the only drug recommended for treating this disease. There have been speculations, of late, concerning O. volvulus resistance to ivermectin. Owing to this, it has become imperative to search for new drugs. World-wide, ethnomedicines including extracts of Euphorbia hirta and Rauvolfia vomitoria are used for treating various diseases, both infectious and non-infectious. Method In this study extracts of the two plants were evaluated in vitro in order to determine their effect against O. volvulus microfilariae. The toxicity of the E. hirta extracts on monkey kidney cell (LLCMK2) lines was also determined. Results The investigations showed that extracts of both plants immobilised microfilariae at different levels in vitro and, therefore, possess antifilarial properties. It was found that all the E. hirta extracts with the exception of the hexane extracts were more effective than those of R. vomitoria. Among the extracts of E. hirta the ethyl acetate fraction was most effective, and comparable to that of dimethanesulphonate salt but higher than that of Melarsoprol (Mel B). However, the crude ethanolic extract of E. hirta was found to be the least toxic to the LLCMK2 compared to the fractionated forms. Conclusions Extracts from both plants possess antifilarial properties; however, the crude extract of E. hirta was found to be least toxic to LLCMK2. PMID:23506674
NASA Astrophysics Data System (ADS)
Su, Zuqiang; Xiao, Hong; Zhang, Yi; Tang, Baoping; Jiang, Yonghua
2017-04-01
Extraction of sensitive features is a challenging but key task in data-driven machinery running state identification. Aimed at solving this problem, a method for machinery running state identification that applies discriminant semi-supervised local tangent space alignment (DSS-LTSA) for feature fusion and extraction is proposed. Firstly, in order to extract more distinct features, the vibration signals are decomposed by wavelet packet decomposition WPD, and a mixed-domain feature set consisted of statistical features, autoregressive (AR) model coefficients, instantaneous amplitude Shannon entropy and WPD energy spectrum is extracted to comprehensively characterize the properties of machinery running state(s). Then, the mixed-dimension feature set is inputted into DSS-LTSA for feature fusion and extraction to eliminate redundant information and interference noise. The proposed DSS-LTSA can extract intrinsic structure information of both labeled and unlabeled state samples, and as a result the over-fitting problem of supervised manifold learning and blindness problem of unsupervised manifold learning are overcome. Simultaneously, class discrimination information is integrated within the dimension reduction process in a semi-supervised manner to improve sensitivity of the extracted fusion features. Lastly, the extracted fusion features are inputted into a pattern recognition algorithm to achieve the running state identification. The effectiveness of the proposed method is verified by a running state identification case in a gearbox, and the results confirm the improved accuracy of the running state identification.
Probabilistic location estimation of acoustic emission sources in isotropic plates with one sensor
NASA Astrophysics Data System (ADS)
Ebrahimkhanlou, Arvin; Salamone, Salvatore
2017-04-01
This paper presents a probabilistic acoustic emission (AE) source localization algorithm for isotropic plate structures. The proposed algorithm requires only one sensor and uniformly monitors the entire area of such plates without any blind zones. In addition, it takes a probabilistic approach and quantifies localization uncertainties. The algorithm combines a modal acoustic emission (MAE) and a reflection-based technique to obtain information pertaining to the location of AE sources. To estimate confidence contours for the location of sources, uncertainties are quantified and propagated through the two techniques. The approach was validated using standard pencil lead break (PLB) tests on an Aluminum plate. The results demonstrate that the proposed source localization algorithm successfully estimates confidence contours for the location of AE sources.
Towards a realistic 3D simulation of the extraction region in ITER NBI relevant ion source
NASA Astrophysics Data System (ADS)
Mochalskyy, S.; Wünderlich, D.; Fantz, U.; Franzen, P.; Minea, T.
2015-03-01
The development of negative ion (NI) sources for ITER is strongly accompanied by modelling activities. The ONIX code addresses the physics of formation and extraction of negative hydrogen ions at caesiated sources as well as the amount of co-extracted electrons. In order to be closer to the experimental conditions the code has been improved. It includes now the bias potential applied to first grid (plasma grid) of the extraction system, and the presence of Cs+ ions in the plasma. The simulation results show that such aspects play an important role for the formation of an ion-ion plasma in the boundary region by reducing the depth of the negative potential well in vicinity to the plasma grid that limits the extraction of the NIs produced at the Cs covered plasma grid surface. The influence of the initial temperature of the surface produced NI and its emission rate on the NI density in the bulk plasma that in turn affects the beam formation region was analysed. The formation of the plasma meniscus, the boundary between the plasma and the beam, was investigated for the extraction potentials of 5 and 10 kV. At the smaller extraction potential the meniscus moves closer to the plasma grid but as in the case of 10 kV the deepest meniscus bend point is still outside of the aperture. Finally, a plasma containing the same amount of NI and electrons (nH- =ne =1017 m-3) , representing good source conditioning, was simulated. It is shown that at such conditions the extracted NI current can reach values of ˜32 mA cm-2 using ITER-relevant extraction potential of 10 kV and ˜19 mA cm-2 at 5 kV. These results are in good agreement with experimental measurements performed at the small scale ITER prototype source at the test facility BATMAN.
Vital physical signals measurements using a webcam
NASA Astrophysics Data System (ADS)
Ouyang, Jianfei; Yan, Yonggang; Yao, Lifeng
2013-10-01
Non-contact and remote measurements of vital physical signals are important for reliable and comfortable physiological self-assessment. In this paper, we provide a new video-based methodology for remote and fast measurements of vital physical signals such as cardiac pulse and breathing rate. A webcam is used to track color video of a human face or wrist, and a Photoplethysmography (PPG) technique is applied to perform the measurements of the vital signals. A novel sequential blind signal extraction methodology is applied to the color video under normal lighting conditions, based on correlation analysis between the green trace and the source signals. The approach is successfully applied in the measurement of vital signals under the condition of different illuminating in which the target signal can also be found out accurately. To assess the advantages, the measuring time of a large number of cases is recorded correctly. The experimental results show that it only takes less than 30 seconds to measure the vital physical signals using presented technique. The study indicates the proposed approach is feasible for PPG technique, which provides a way to study the relationship of the signal for different ROI in future research.
A first application of independent component analysis to extracting structure from stock returns.
Back, A D; Weigend, A S
1997-08-01
This paper explores the application of a signal processing technique known as independent component analysis (ICA) or blind source separation to multivariate financial time series such as a portfolio of stocks. The key idea of ICA is to linearly map the observed multivariate time series into a new space of statistically independent components (ICs). We apply ICA to three years of daily returns of the 28 largest Japanese stocks and compare the results with those obtained using principal component analysis. The results indicate that the estimated ICs fall into two categories, (i) infrequent large shocks (responsible for the major changes in the stock prices), and (ii) frequent smaller fluctuations (contributing little to the overall level of the stocks). We show that the overall stock price can be reconstructed surprisingly well by using a small number of thresholded weighted ICs. In contrast, when using shocks derived from principal components instead of independent components, the reconstructed price is less similar to the original one. ICA is shown to be a potentially powerful method of analyzing and understanding driving mechanisms in financial time series. The application to portfolio optimization is described in Chin and Weigend (1998).
OPERATOR NORM INEQUALITIES BETWEEN TENSOR UNFOLDINGS ON THE PARTITION LATTICE
Wang, Miaoyan; Duc, Khanh Dao; Fischer, Jonathan; Song, Yun S.
2017-01-01
Interest in higher-order tensors has recently surged in data-intensive fields, with a wide range of applications including image processing, blind source separation, community detection, and feature extraction. A common paradigm in tensor-related algorithms advocates unfolding (or flattening) the tensor into a matrix and applying classical methods developed for matrices. Despite the popularity of such techniques, how the functional properties of a tensor changes upon unfolding is currently not well understood. In contrast to the body of existing work which has focused almost exclusively on matricizations, we here consider all possible unfoldings of an order-k tensor, which are in one-to-one correspondence with the set of partitions of {1, …, k}. We derive general inequalities between the lp-norms of arbitrary unfoldings defined on the partition lattice. In particular, we demonstrate how the spectral norm (p = 2) of a tensor is bounded by that of its unfoldings, and obtain an improved upper bound on the ratio of the Frobenius norm to the spectral norm of an arbitrary tensor. For specially-structured tensors satisfying a generalized definition of orthogonal decomposability, we prove that the spectral norm remains invariant under specific subsets of unfolding operations. PMID:28286347
Wang, Huaqing; Li, Ruitong; Tang, Gang; Yuan, Hongfang; Zhao, Qingliang; Cao, Xi
2014-01-01
A Compound fault signal usually contains multiple characteristic signals and strong confusion noise, which makes it difficult to separate week fault signals from them through conventional ways, such as FFT-based envelope detection, wavelet transform or empirical mode decomposition individually. In order to improve the compound faults diagnose of rolling bearings via signals’ separation, the present paper proposes a new method to identify compound faults from measured mixed-signals, which is based on ensemble empirical mode decomposition (EEMD) method and independent component analysis (ICA) technique. With the approach, a vibration signal is firstly decomposed into intrinsic mode functions (IMF) by EEMD method to obtain multichannel signals. Then, according to a cross correlation criterion, the corresponding IMF is selected as the input matrix of ICA. Finally, the compound faults can be separated effectively by executing ICA method, which makes the fault features more easily extracted and more clearly identified. Experimental results validate the effectiveness of the proposed method in compound fault separating, which works not only for the outer race defect, but also for the rollers defect and the unbalance fault of the experimental system. PMID:25289644
OPERATOR NORM INEQUALITIES BETWEEN TENSOR UNFOLDINGS ON THE PARTITION LATTICE.
Wang, Miaoyan; Duc, Khanh Dao; Fischer, Jonathan; Song, Yun S
2017-05-01
Interest in higher-order tensors has recently surged in data-intensive fields, with a wide range of applications including image processing, blind source separation, community detection, and feature extraction. A common paradigm in tensor-related algorithms advocates unfolding (or flattening) the tensor into a matrix and applying classical methods developed for matrices. Despite the popularity of such techniques, how the functional properties of a tensor changes upon unfolding is currently not well understood. In contrast to the body of existing work which has focused almost exclusively on matricizations, we here consider all possible unfoldings of an order- k tensor, which are in one-to-one correspondence with the set of partitions of {1, …, k }. We derive general inequalities between the l p -norms of arbitrary unfoldings defined on the partition lattice. In particular, we demonstrate how the spectral norm ( p = 2) of a tensor is bounded by that of its unfoldings, and obtain an improved upper bound on the ratio of the Frobenius norm to the spectral norm of an arbitrary tensor. For specially-structured tensors satisfying a generalized definition of orthogonal decomposability, we prove that the spectral norm remains invariant under specific subsets of unfolding operations.
Derbidge, Renatus; Feiten, Linus; Conradt, Oliver; Heusser, Peter; Baumgartner, Stephan
2013-01-01
Photographs of mistletoe (Viscum album L.) berries taken by a permanently fixed camera during their development in autumn were subjected to an outline shape analysis by fitting path curves using a mathematical algorithm from projective geometry. During growth and maturation processes the shape of mistletoe berries can be described by a set of such path curves, making it possible to extract changes of shape using one parameter called Lambda. Lambda describes the outline shape of a path curve. Here we present methods and software to capture and measure these changes of form over time. The present paper describes the software used to automatize a number of tasks including contour recognition, optimization of fitting the contour via hill-climbing, derivation of the path curves, computation of Lambda and blinding the pictures for the operator. The validity of the program is demonstrated by results from three independent measurements showing circadian rhythm in mistletoe berries. The program is available as open source and will be applied in a project to analyze the chronobiology of shape in mistletoe berries and the buds of their host trees. PMID:23565255
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazurek, M.A.; Hildemann, L.M.; Cass, G.R.
1990-04-01
Extractable organic compounds having between 6 to 40 carbon atoms comprise an important mass fraction of the fine particulate matter samples from major urban emission sources. Depending on the emission source type, this solvent-soluble fraction accounts for <20% to 100% of the total organic aerosol mass, as measured by quantitative high-resolution has chromatography (HRGC) with flame ionization detection. In addition to total extract quantitation, HRGC can be applied to further analyses of the mass distributions of elutable organics present in the complex aerosol extract mixtures, thus generating profiles that serve as fingerprints'' for the sources of interest. This HRGC analyticalmore » method is applied to emission source samples that contain between 7 to 12,000 {mu}g/filter organic carbon. It is shown to be a sensitive technique for analysis of carbonaceous aerosol extract mixtures having diverse mass loadings and species distributions. This study describes the analytical chemical methods that have been applied to: the construction of chemical mass balances based on the mass of fine organic aerosol emitted for major urban sources of particulate carbon; and the generation of discrete emission source chemical profiles derived from chromatographic characteristics of the organic aerosol components. 21 refs., 1 fig., 2 tabs.« less
NASA Astrophysics Data System (ADS)
Capuano, Paolo; De Lauro, Enza; De Martino, Salvatore; Falanga, Mariarosaria; Petrosino, Simona
2015-04-01
One of the main challenge in volcano-seismological literature is to locate and characterize the source of volcano/tectonic seismic activity. This passes through the identification at least of the onset of the main phases, i.e. the body waves. Many efforts have been made to solve the problem of a clear separation of P and S phases both from a theoretical point of view and developing numerical algorithms suitable for specific cases (see, e.g., Küperkoch et al., 2012). Recently, a robust automatic procedure has been implemented for extracting the prominent seismic waveforms from continuously recorded signals and thus allowing for picking the main phases. The intuitive notion of maximum non-gaussianity is achieved adopting techniques which involve higher-order statistics in frequency domain., i.e, the Convolutive Independent Component Analysis (CICA). This technique is successful in the case of the blind source separation of convolutive mixtures. In seismological framework, indeed, seismic signals are thought as the convolution of a source function with path, site and the instrument response. In addition, time-delayed versions of the same source exist, due to multipath propagation typically caused by reverberations from some obstacle. In this work, we focus on the Volcano Tectonic (VT) activity at Campi Flegrei Caldera (Italy) during the 2006 ground uplift (Ciaramella et al., 2011). The activity was characterized approximately by 300 low-magnitude VT earthquakes (Md < 2; for the definition of duration magnitude, see Petrosino et al. 2008). Most of them were concentrated in distinct seismic sequences with hypocenters mainly clustered beneath the Solfatara-Accademia area, at depths ranging between 1 and 4 km b.s.l.. The obtained results show the clear separation of P and S phases: the technique not only allows the identification of the S-P time delay giving the timing of both phases but also provides the independent waveforms of the P and S phases. This is an enormous advantage for all the problems related to the source inversion and location In addition, the VT seismicity was accompanied by hundreds of LP events (characterized by spectral peaks in the 0.5-2-Hz frequency band) that were concentrated in a 7-day interval. The main interest is to establish whether the occurrence of LPs is only limited to the swarm that reached a climax on days 26-28 October as indicated by Saccorotti et al. (2007), or a longer period is experienced. The automatically extracted waveforms with improved signal-to-noise ratio via CICA coupled with automatic phase picking allowed to compile a more complete seismic catalog and to better quantify the seismic energy release including the presence of LP events from the beginning of October until mid of November. Finally, a further check of the volcanic nature of extracted signals is achieved by looking at the seismological properties and the content of entropy held in the traces (Falanga and Petrosino 2012; De Lauro et al., 2012). Our results allow us to move towards a full description of the complexity of the source, which can be used for hazard-model development and forecast-model testing, showing an illustrative example of the applicability of the CICA method to regions with low seismicity in high ambient noise
Khan, S R; Qazi, S R
2017-11-01
Palatal infiltration of local anaesthesia (LA) for maxillary tooth extractions is painful. One of the techniques for reducing the discomfort of this injection is to avoid it altogether. Given enough time, LA administered only as buccal infiltration diffuses to reach and anaesthetise the palatal tissues. The aim of this double-blind randomised controlled trial was to test the hypothesis that buccal infiltration alone of LA by dental students should be adequate for maxillary tooth extractions. Fifty adult patients presenting for single-tooth maxillary extractions were randomly allocated between two groups. The control group received palatal injections of 0.1 ml 2% lidocaine with 1:100,000 adrenaline, whilst the experimental group received a similar amount of saline (placebo). Extractions performed without further administration of LA were categorised as successful. Palatal infiltration of lidocaine with adrenaline was significantly more effective than saline (P = 0.002). Overall buccal infiltration alone was successful in 28% patients, with a 40% success rate in the posterior maxilla. Results suggest that dental students should, as a matter of routine, extract maxillary teeth with both buccal and palatal infiltration of LA, whilst buccal infiltration alone may be considered in the posterior maxilla. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowe, N.J.; Wortzman, M.S.; Breeding, J.
1983-06-01
Recent studies have questioned the therapeutic value of coal tar versus ultraviolet (UV) radiation and their relative necessity in phototherapy for psoriasis. In this investigation, different aspects of tar phototherapy have been studied in single-blind bilateral paired comparison studies. The effects of 1% crude coal tar were compared with those of petrolatum in conjunction with erythemogenic and suberythemogenic doses of ultraviolet light (UVB) using a FS72 sunlamp tubed cabinet. Crude coal tar was clinically superior to petrolatum with suberythemogenic ultraviolet. With the erythemogenic UVB, petrolatum was equal in efficacy to crude coal tar. Suberythemogenic UVB was also used adjunctively tomore » compare the effects of a 5% concentration of a tar extract in an oil base to 5% crude coal tar in petrolatum or the oil base without tar. The tar extract in oil plus suberythemogenic UVB produced significantly more rapid improvement than the oil base plus UVB. The direct bilateral comparison of equal concentrations of tar extract in oil base versus crude coal tar in petrolatum in a suberythemogenic UV photo regimen revealed no statistical differences between treatments. In a study comparing tar extract in oil and the oil base without ultraviolet radiation, the tar extract in oil side responded more rapidly.« less
NASA Astrophysics Data System (ADS)
See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.
A continuing quality-assurance program has been operated by the U.S. Geological Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca 2+, Mg 2+, Na 2+, K +, SO 42- and Cl -1 in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contamination in blind-audit samples indicate a decrease in the median concentration and ranges of Ca 2+, Mg 2+ and SO 42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca 2+, Mg 2+, Na -, K + and SO 42- and Cl - concentrations, and underestimates of H + concentrations.
Prevalence of visual impairment and blindness in Upper Egypt: a gender-based perspective.
Mousa, Ahmed; Courtright, Paul; Kazanjian, Arminee; Bassett, Ken
2014-06-01
To estimate the prevalence, causes of and risk factors for vision loss in Upper Egypt. In this cross-sectional study, four villages in Upper Egypt were randomly selected; within these four villages, households were randomly selected and within the selected households all residents aged ≥ 40 years were enumerated and enrolled. Door-to-door eye examinations of household members were conducted. Data on relevant demographic and socioeconomic characteristics were collected. The prevalence and causes of vision loss and associated risk factors were assessed. Sex differences in prevalence and determinants were also evaluated. The prevalence of best eye presenting visual impairment, severe visual impairment, and blindness were 23.9%, 6.4%, and 9.3% respectively. The prevalence of blindness among women significantly exceeded that among men (11.8% vs. 5.4%, respectively, p = 0.021). The prevalence of cataract was 22.9% (higher in women, 26.5% than men 17.2%, p = 0.018). The prevalence of trachomatous trichiasis was 9.7% (higher among women, 12.5%, than men, 5.4%, p = 0.012). The principal causes of blindness were cataract (60%), uncorrected refractive errors (16%) and corneal opacities (12%). Age, sex, family size, illiteracy, unemployment, water source and sanitation methods and living conditions were the major risk factors for vision loss. The prevalence of visual impairment remains high in Egypt, particularly among women. Risk factors for blindness may differ between men and women. There is a need for qualitative investigations to better understand the causes behind the excess in prevalence of blindness among women.
See, R.B.; Schroder, L.J.; Willoughby, T.C.
1989-01-01
A continuing quality-assurance program has been operated by the U.S. Geographical Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca2+, Mg2+, K+ SO42+ and Cl- in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contaminations in blind-audit samples indicate a decrease in the median concentration and ranges of Ca2+, Mg2+ and SO42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca2+, Mg2+, Na-, K+, SO42- and Cl- concentrations, and underestimates of H+ concentrations.
Meijun Li,; Ellis, Geoffrey S.
2015-01-01
Dibenzofuran (DBF), its alkylated homologues, and benzo[b]naphthofurans (BNFs) are common oxygen-heterocyclic aromatic compounds in crude oils and source rock extracts. A series of positional isomers of alkyldibenzofuran and benzo[b]naphthofuran were identified in mass chromatograms by comparison with internal standards and standard retention indices. The response factors of dibenzofuran in relation to internal standards were obtained by gas chromatography-mass spectrometry analyses of a set of mixed solutions with different concentration ratios. Perdeuterated dibenzofuran and dibenzothiophene are optimal internal standards for quantitative analyses of furan compounds in crude oils and source rock extracts. The average concentration of the total DBFs in oils derived from siliciclastic lacustrine rock extracts from the Beibuwan Basin, South China Sea, was 518 μg/g, which is about 5 times that observed in the oils from carbonate source rocks in the Tarim Basin, Northwest China. The BNFs occur ubiquitously in source rock extracts and related oils of various origins. The results of this work suggest that the relative abundance of benzo[b]naphthofuran isomers, that is, the benzo[b]naphtho[2,1-d]furan/{benzo[b]naphtho[2,1-d]furan + benzo[b]naphtho[1,2-d]furan} ratio, may be a potential molecular geochemical parameter to indicate oil migration pathways and distances.
Modeling of negative ion transport in a plasma source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riz, David; Departement de Recherches sur la Fusion Controelee CE Cadarache, 13108 St Paul lez Durance; Pamela, Jerome
1998-08-20
A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The ion trajectory is calculated by numerically solving the 3-D motion equation, while the atomic processes of destruction, of elastic collision H{sup -}/H{sup +} and of charge exchange H{sup -}/H{sup 0} are handled at each time step by a Monte-Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have allowed to explain, either quantitatively or qualitatively, severalmore » phenomena observed in negative ion sources, such as the isotopic H{sup -}/D{sup -} effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm{sup -3}), negative ions can reach the extraction region provided if they are produced at a distance lower than 2 cm from the plasma grid in the case of 'volume production' (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.« less
Modeling of negative ion transport in a plasma source (invited)
NASA Astrophysics Data System (ADS)
Riz, David; Paméla, Jérôme
1998-02-01
A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The H-/D- trajectory is calculated by numerically solving the 3D motion equation, while the atomic processes of destruction, of elastic collision with H+/D+ and of charge exchange with H0/D0 are handled at each time step by a Monte Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have been allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that, in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided they are produced at a distance lower than 2 cm from the plasma grid in the case of volume production (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.
Modeling of negative ion transport in a plasma source
NASA Astrophysics Data System (ADS)
Riz, David; Paméla, Jérôme
1998-08-01
A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The ion trajectory is calculated by numerically solving the 3-D motion equation, while the atomic processes of destruction, of elastic collision H-/H+ and of charge exchange H-/H0 are handled at each time step by a Monte-Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided if they are produced at a distance lower than 2 cm from the plasma grid in the case of «volume production» (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.
Evaluation of Genotoxic and Mutagenic Activity of Organic Extracts from Drinking Water Sources
Guan, Ying; Wang, Xiaodong; Wong, Minghung; Sun, Guoping; An, Taicheng; Guo, Jun
2017-01-01
An increasing number of industrial, agricultural and commercial chemicals in the aquatic environment lead to various deleterious effects on organisms, which is becoming a serious global health concern. In this study, the Ames test and SOS/umu test were conducted to investigate the potential genotoxicity and mutagenicity caused by organic extracts from drinking water sources. Organic content of source water was extracted with XAD-2 resin column and organic solvents. Four doses of the extract equivalent to 0.25, 0.5, 1 and 2L of source water were tested for toxicity. All the water samples were collected from six different locations in Guangdong province. The results of the Ames test and SOS/umu test showed that all the organic extracts from the water samples could induce different levels of DNA damage and mutagenic potentials at the dose of 2 L in the absence of S9 mix, which demonstrated the existence of genotoxicity and mutagenicity. Additionally, we found that Salmonella typhimurium strain TA98 was more sensitive for the mutagen. Correlation analysis between genotoxicity, Organochlorine Pesticides (OCPs) and Polycyclic Aromatic Hydrocarbons (PAHs) showed that most individual OCPs were frame shift toxicants in drinking water sources, and there was no correlation with total OCPs and PAHs. PMID:28125725
Double Blind Test For Bio-Stimulation Effects On Pain Relief By Diode Laser
NASA Astrophysics Data System (ADS)
Saeki, Norio; Sembokuya, Iwajiro; Arakawa, Kazuo; Fujimasa, Iwao; Mabuchi, Kunihiko; Abe, Yuusuke; Atsumi, Kazuhiko
1989-09-01
The bio-stimulation effect of semiconductor laser on therapeutic pain relief was investigated by conducting a double blind test performed on more than one hundred patient subjects suffering from various neualgia. A compact laser therapeutic equipment with two laser probes each having 60 mW power was developed and utilized for the experiment. Each probe was driven by either the active or the dummy source selected randomly, and its results were stored in the memory for statistical processing. The therapeutic treatments including active and dummy treatments were performed on 102 subjects. The pain relief effects were confirmed for 85.5% of the subjects.
FPGA implementation of ICA algorithm for blind signal separation and adaptive noise canceling.
Kim, Chang-Min; Park, Hyung-Min; Kim, Taesu; Choi, Yoon-Kyung; Lee, Soo-Young
2003-01-01
An field programmable gate array (FPGA) implementation of independent component analysis (ICA) algorithm is reported for blind signal separation (BSS) and adaptive noise canceling (ANC) in real time. In order to provide enormous computing power for ICA-based algorithms with multipath reverberation, a special digital processor is designed and implemented in FPGA. The chip design fully utilizes modular concept and several chips may be put together for complex applications with a large number of noise sources. Experimental results with a fabricated test board are reported for ANC only, BSS only, and simultaneous ANC/BSS, which demonstrates successful speech enhancement in real environments in real time.
A blind green bank telescope millimeter-wave survey for redshifted molecular absorption
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanekar, N.; Gupta, A.; Carilli, C. L.
2014-02-10
We present the methodology for 'blind' millimeter-wave surveys for redshifted molecular absorption in the CO/HCO{sup +} rotational lines. The frequency range 30-50 GHz appears optimal for such surveys, providing sensitivity to absorbers at z ≳ 0.85. It is critical that the survey is 'blind', i.e., based on a radio-selected sample, including sources without known redshifts. We also report results from the first large survey of this kind, using the Q-band receiver on the Green Bank Telescope (GBT) to search for molecular absorption toward 36 sources, 3 without known redshifts, over the frequency range 39.6-49.5 GHz. The GBT survey has amore » total redshift path of Δz ≈ 24, mostly at 0.81 < z < 1.91, and a sensitivity sufficient to detect equivalent H{sub 2} column densities ≳ 3 × 10{sup 21} cm{sup –2} in absorption at 5σ significance (using CO-to-H{sub 2} and HCO{sup +}-to-H{sub 2} conversion factors of the Milky Way). The survey yielded no confirmed detections of molecular absorption, yielding the 2σ upper limit n(z = 1.2) < 0.15 on the redshift number density of molecular gas at column densities N(H{sub 2}) ≳ 3 × 10{sup 21} cm{sup –2}.« less
Speech-Message Extraction from Interference Introduced by External Distributed Sources
NASA Astrophysics Data System (ADS)
Kanakov, V. A.; Mironov, N. A.
2017-08-01
The problem of this study involves the extraction of a speech signal originating from a certain spatial point and calculation of the intelligibility of the extracted voice message. It is solved by the method of decreasing the influence of interference from the speech-message sources on the extracted signal. This method is based on introducing the time delays, which depend on the spatial coordinates, to the recording channels. Audio records of the voices of eight different people were used as test objects during the studies. It is proved that an increase in the number of microphones improves intelligibility of the speech message which is extracted from interference.
Eftekhari, Mohammad Hassan; Rostami, Zahra Hassanzadeh; Emami, Mohammad Jafar; Tabatabaee, Hamid Reza
2014-01-01
The purpose of this study was to investigate the effects of the combination of vitex agnus castus extract, as a source of phytoestrogens, plus magnesium supplementation on osteogenic and angiogenic factors and callus formation in women with long bone fracture. In a double-blind randomized placebo controlled trial, 64 women with long bone fracture, 20-45 years old, were randomly allocated to receive 1) one Agnugol tablet (4 mg dried fruit extract of vitex agnus castus) plus 250 mg magnesium oxide (VAC + Mg group (n = 10)), 2) one Agnugol tablet plus placebo (VAC group (n = 15)), 3) placebo plus 250 mg magnesium oxide (Mg group (n = 12)), or 4) placebo plus placebo (placebo group (n = 14)) per day for 8 weeks. At baseline and endpoint of the trial, serum alkaline phosphatase, osteocalcin, and vascular endothelial growth factor (VEGF) were measured together with radiological bone assessment. There were no significant differences in the characteristic aspects of concern between the four groups at baseline. Despite the increased level of alkaline phosphatase in the VAC group (188.33 ± 16.27 to 240.40 ± 21.49, P = 0.05), administration of VAC + Mg could not increase alkaline phosphatase activity. However, treatment with VAC + Mg significantly enhanced the osteocalcin level. The serum concentration of VEGF was increased in the VAC group (269.04 ± 116.63 to 640.03 ± 240.16, P < 0.05). Callus formation in the VAC + Mg group was higher than the other groups but the differences between the four groups were not significant (P = 0.39). No relevant side effect was observed in patients in each group. Our results suggest that administration of vitex agnus castus plus magnesium may promote fracture healing. However, more studies need to further explore the roles of vitex agnus castus in fracture repair processes.
Eftekhari, Mohammad Hassan; Rostami, Zahra Hassanzadeh; Emami, Mohammad Jafar; Tabatabaee, Hamid Reza
2014-01-01
Background: The purpose of this study was to investigate the effects of the combination of vitex agnus castus extract, as a source of phytoestrogens, plus magnesium supplementation on osteogenic and angiogenic factors and callus formation in women with long bone fracture. Material and Methods: In a double-blind randomized placebo controlled trial, 64 women with long bone fracture, 20-45 years old, were randomly allocated to receive 1) one Agnugol tablet (4 mg dried fruit extract of vitex agnus castus) plus 250 mg magnesium oxide (VAC + Mg group (n = 10)), 2) one Agnugol tablet plus placebo (VAC group (n = 15)), 3) placebo plus 250 mg magnesium oxide (Mg group (n = 12)), or 4) placebo plus placebo (placebo group (n = 14)) per day for 8 weeks. At baseline and endpoint of the trial, serum alkaline phosphatase, osteocalcin, and vascular endothelial growth factor (VEGF) were measured together with radiological bone assessment. Results: There were no significant differences in the characteristic aspects of concern between the four groups at baseline. Despite the increased level of alkaline phosphatase in the VAC group (188.33 ± 16.27 to 240.40 ± 21.49, P = 0.05), administration of VAC + Mg could not increase alkaline phosphatase activity. However, treatment with VAC + Mg significantly enhanced the osteocalcin level. The serum concentration of VEGF was increased in the VAC group (269.04 ± 116.63 to 640.03 ± 240.16, P < 0.05). Callus formation in the VAC + Mg group was higher than the other groups but the differences between the four groups were not significant (P = 0.39). No relevant side effect was observed in patients in each group. Conclusion: Our results suggest that administration of vitex agnus castus plus magnesium may promote fracture healing. However, more studies need to further explore the roles of vitex agnus castus in fracture repair processes. PMID:24672557
NASA Astrophysics Data System (ADS)
Muravsky, Leonid I.; Kmet', Arkady B.; Stasyshyn, Ihor V.; Voronyak, Taras I.; Bobitski, Yaroslav V.
2018-06-01
A new three-step interferometric method with blind phase shifts to retrieve phase maps (PMs) of smooth and low-roughness engineering surfaces is proposed. Evaluating of two unknown phase shifts is fulfilled by using the interframe correlation between interferograms. The method consists of two stages. The first stage provides recording of three interferograms of a test object and their processing including calculation of unknown phase shifts, and retrieval of a coarse PM. The second stage implements firstly separation of high-frequency and low-frequency PMs and secondly producing of a fine PM consisting of areal surface roughness and waviness PMs. Extraction of the areal surface roughness and waviness PMs is fulfilled by using a linear low-pass filter. The computer simulation and experiments fulfilled to retrieve a gauge block surface area and its areal surface roughness and waviness have confirmed the reliability of the proposed three-step method.
A blind dual color images watermarking based on IWT and state coding
NASA Astrophysics Data System (ADS)
Su, Qingtang; Niu, Yugang; Liu, Xianxi; Zhu, Yu
2012-04-01
In this paper, a state-coding based blind watermarking algorithm is proposed to embed color image watermark to color host image. The technique of state coding, which makes the state code of data set be equal to the hiding watermark information, is introduced in this paper. When embedding watermark, using Integer Wavelet Transform (IWT) and the rules of state coding, these components, R, G and B, of color image watermark are embedded to these components, Y, Cr and Cb, of color host image. Moreover, the rules of state coding are also used to extract watermark from the watermarked image without resorting to the original watermark or original host image. Experimental results show that the proposed watermarking algorithm cannot only meet the demand on invisibility and robustness of the watermark, but also have well performance compared with other proposed methods considered in this work.
NASA Astrophysics Data System (ADS)
Liu, Tingting; Liu, Hai; Chen, Zengzhao; Chen, Yingying; Wang, Shengming; Liu, Zhi; Zhang, Hao
2018-05-01
Infrared (IR) spectra are the fingerprints of the molecules, and the spectral band location closely relates to the structure of a molecule. Thus, specimen identification can be performed based on IR spectroscopy. However, spectrally overlapping components prevent the specific identification of hyperfine molecular information of different substances. In this paper, we propose a fast blind reconstruction approach for IR spectra, which is based on sparse and redundant representations over a dictionary. The proposed method recovers the spectrum with the discrete wavelet transform dictionary on its content. The experimental results demonstrate that the proposed method is superior because of the better performance when compared with other state-of-the-art methods. The method the authors used remove the instrument aging issue to a large extent, thus leading the reconstruction IR spectra a more convenient tool for extracting features of an unknown material and interpreting it.
Torres-Pérez, Mónica I; Jiménez-Velez, Braulio D; Mansilla-Rivera, Imar; Rodríguez-Sierra, Carlos J
2005-03-01
The effect that three extraction techniques (e.g., Soxhlet, ultrasound and microwave-assisted extraction) have on the toxicity, as measured by submitochondrial particle (SMP) and Microtox assays, of organic extracts was compared from three sources of airborne particulate matter (APM). The extraction technique influenced the toxicity response of APM extracts and it was dependent on the bioassay method, and APM sample source. APM extracts from microwave-assisted extraction (MAE) were similar or more toxic than the conventional extraction techniques of Soxhlet and ultrasound, thus, providing an alternate extraction method. The microwave extraction technique has the advantage of using less solvent volume, less extraction time, and the capacity to simultaneously extract twelve samples. The ordering of APM toxicity was generally urban dust > diesel dust > PM10 (particles with diameter < 10 microm), thus, reflecting different chemical composition of the samples. This study is the first to report the suitability of two standard in-vitro bioassays for the future toxicological characterization of APM collected from Puerto Rico, with the SMP generally showing better sensitivity to the well-known Microtox bioassay.
Kennedy, David O; Jackson, Philippa A; Forster, Joanne; Khan, Julie; Grothe, Torsten; Perrinjaquet-Moccetti, Tania; Haskell-Ramsay, Crystal F
2017-02-01
A wild green-oats extract (Neuravena ® ) containing a range of potentially bioactive components, including flavonoids and triterpene saponins, has previously been shown to enhance animal stress responses and memory, and improve cognitive performance in humans at a dose of 1600 mg. Methods This double-blind, placebo-controlled, counterbalanced cross-over study assessed the effects of single doses of the green-oat extract (GOE) across a broad range of cognitive domains in healthy adults aged 40-65 years who self-reported that they felt that their memory had declined with age. Participants attended on six occasions, receiving a single dose of either placebo, 800, or 1600 mg GOE on each occasion, with the counterbalanced order of treatments repeated twice for each participant. Cognitive function was assessed with a range of computerized tasks measuring attention, spatial/working/episodic memory, and executive function pre-dose and at 1, 2.5, 4, and 6 hours post-dose. Results The results showed that 800mg GOE increased the speed of performance across post-dose assessments on a global measure including data from all of the timed tasks. It also improved performance of a delayed word recall task in terms of errors and an executive function task (Peg and Ball) in terms of decreased thinking time and overall completion time. Working memory span (Corsi blocks) was also increased, but only on the second occasion that this dose was taken. Discussion These results confirm the acute cognitive effects of GOE seen in previous research, and suggest that the optimal dose lies at or below 800 mg.
Cho, Young-Gyu; Jung, Ji-Hye; Kang, Jae-Heon; Kwon, Jin Soo; Yu, Seung Pil; Baik, Tae Gon
2017-07-28
YY-312 is a herbal extract powder from Imperata cylindrica Beauvois, Citrus unshiu Markovich, and Evodia officinalis Dode, which have health promoting effects, including body fat reduction. We aimed to evaluate the efficacy and safety of YY-312 for body fat reduction in overweight adults. This was a 12-week, randomized, double-blind, placebo-controlled, parallel-group clinical trial performed in overweight Korean adults aged 19-60 years with a body mass index of 25.0-29.9 kg/m 2 . The daily dose of YY-312 was 2400 mg (containing 1800 mg of active herbal extract and 600 mg of cyclodextrin). Primary outcomes were reductions in body fat mass (BFM) and body fat percentage (BF%) after 12 weeks. Secondary outcomes included reductions in body weight and waist circumference (WC) after 12 weeks. After 12 weeks, BFM (1.6 kg vs. 0.1 kg; P = 0.023) and BF% (1.5% vs. -0.2%; P = 0.018) decreased significantly more in the YY-312 group than in the placebo group, as did body weight (2.7 kg vs. 1.0 kg; P = 0.014) and WC (2.2 cm vs. 0.8 cm; P = 0.049). All safety parameters were within normal limits; no serious adverse events occurred in either group. In a 12-week clinical trial in overweight adults, YY-312 resulted in significantly greater reduction in body fat vs. placebo, while being safe and well tolerated. cris.nih.go.kr: ( KCT0001225 ).
Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco Javier; Muñoz-López, Jose Luis; Vallecillo-Capilla, Manuel Francisco; Reyes-Botella, Candela
2018-02-15
The objective of this randomized controlled clinical trial (RCT) was to compare the effect of bupivacaine and articaine at habitual doses on pain intensity and the need for analgesics after lower third molar extraction. The final study sample comprised 50 Caucasian volunteers (26 males and 24 females; age range, 18-30 years) undergoing scheduled surgical extraction of impacted lower third molar. A computer-generated random sequence was used to allocate participants to the articaine (4%) or bupivacaine (0.5%) group. Surgeons and patients were blinded by labeling the articaine and bupivacaine carpules with numbers (1 and 2, respectively). Postoperative pain intensity (primary outcome) was evaluated with a visual analogue scale (VAS), while the requirement for and timing of rescue medication and the quality of intraoperative anesthesia were also measured (secondary outcomes). VAS-measured pain intensity was significantly higher (p < 0.05) in the articaine group than in the bupivacaine group at all time points except for 8 h post-surgery (p = 0.052). Rescue medication was required by 13 (52%) patients in the articaine group and 8 (32%) patients in the bupivacaine group, although the difference did not reach statistical significance (p = 0.252). The groups did not significantly differ (p = 0.391) in the quality of the intraoperative anesthesia. Bupivacaine is a valid alternative to articaine in third molar surgery and may offer residual anesthesia as a means of reducing postoperative pain. However, further well-designed RCTs are required in larger study populations to verify the effectiveness of bupivacaine to achieve residual analgesia after oral surgery. These findings suggest that bupivacaine may be useful as a coadjuvant to control acute postoperative pain. ACTRN12617001138370.
NASA Astrophysics Data System (ADS)
Turnbull, Margaret
The WFIRST mission is now envisioned to include a coronagraph for the purpose of direct detection of nearby exoplanets, including planets known to exist via radial velocity detection and new discoveries. Assuming that starlight rejection sufficient for planet detection (~1e-9) can be achieved, what can be learned about these planets given a realistic spectral resolution and signal-to-noise ratio? We propose to investigate the potential for WFIRST to efficiently discriminate planets from background sources, and to characterize planets in terms of important diagnostic atmospheric features, using broad- and intermediate band color data. We will map out this capability as a function of signal-to-noise ratio, bandpass location, and bandpass width. Our investigation will place emphasis on gas giants, ice giants, and mini-Neptunes (compatible with current AFTA-C baseline performance specifications), as well as a variety of super-Earths (an AFTA-C "stretch" goal). We will explore a variety of compositions, cloud types, phase angles, and (in the case of super-Earths with semi-transparent atmospheres) surface types. Noiseless spectra generated for these model planets will be passed through (a) standard bandpasses for comparison to prior work and (b) filter transmission curves corresponding to bandpasses of 5-20% over the full range of WFIRST's expected bandpass (400 - 1,000 nm). From this, filter combinations will be used to generate planet colors and find filter sets that most efficiently discriminate between planets and background sources, and between planets of different type. We will then repeat this exercise for S/N levels of 1-1,000 in order to (1) explore the true efficacy of broadband measurements in exoplanet studies, and (2) provide an estimate of total required integration time for a compelling WFIRST exoplanet program. To accomplish this, we will use model spectra for mini-Neptunes, and ice and gas giants of varying composition (Hu et al. 2013), and observed spectra for Solar System objects (Jupiter, Saturn, Uranus, Neptune, and Titan; Karcoschka 1994). We will also use observed SCIAMACHY spectra for the desert, ocean, forest, and icy Earth, in order to build a diverse set of spatially integrated super-Earth spectra, plus variations in atmospheric composition. Simulated observed spectra will be generated for planets placed under the irradiance of stellar spectral types corresponding to WFIRST's highest priority targets for exoplanet imaging (approximately K5V through F5V). The colors extracted from these spectra will be compared to colors extracted from spectra for a wide range of likely extragalactic sources (Bruzual & Charlott 2003) and extincted stellar background sources. Finally, we will assess the "background threat" for the 100 most favorable targets for exoplanet imaging with WFIRST. This flag will be assigned based on number and type of background sources expected at various galactic latitudes, and the above results indicating how readily such sources can be discriminated from exoplanets. As a result of this intensive, three year effort, we will deliver to the community a library of planet spectra and colors in standard and proposed "designer" passbands for planets of all types under stars of varying spectral type, plus colors for a wide range of expected stellar and extragalactic background sources. These data will be available for future work in simulating images and eventual "double blind" studies in extracting planet sources and atmospheric signatures. We expect that our investigation will inform WFIRST and all future direct imaging missions of (1) how different planets will appear at "first glance" from the likely sea of background of stars and unresolved extragalactic sources, and (2) the necessary performance specifications required to characterize the most important atmospheric constituents and discriminate between planets of varying type.
Adapting smart phone applications about physics education to blind students
NASA Astrophysics Data System (ADS)
Bülbül, M. Ş.; Yiğit, N.; Garip, B.
2016-04-01
Today, most of necessary equipment in a physics laboratory are available for smartphone users via applications. Physics teachers may measure from acceleration to sound volume with its internal sensors. These sensors collect data and smartphone applications make the raw data visible. Teachers who do not have well-equipped laboratories at their schools may have an opportunity to conduct experiments with the help of smart phones. In this study, we analyzed possible open source physics education applications in terms of blind users in inclusive learning environments. All apps are categorized as partially, full or non-supported. The roles of blind learner’s friend during the application are categorized as reader, describer or user. Mentioned apps in the study are compared with additional opportunities like size and downloading rates. Out of using apps we may also get information about whether via internet and some other extra information for different experiments in physics lab. Q-codes reading or augmented reality are two other opportunity provided by smart phones for users in physics labs. We also summarized blind learner’s smartphone experiences from literature and listed some suggestions for application designers about concepts in physics.
First results of the ITER-relevant negative ion beam test facility ELISE (invited).
Fantz, U; Franzen, P; Heinemann, B; Wünderlich, D
2014-02-01
An important step in the European R&D roadmap towards the neutral beam heating systems of ITER is the new test facility ELISE (Extraction from a Large Ion Source Experiment) for large-scale extraction from a half-size ITER RF source. The test facility was constructed in the last years at Max-Planck-Institut für Plasmaphysik Garching and is now operational. ELISE is gaining early experience of the performance and operation of large RF-driven negative hydrogen ion sources with plasma illumination of a source area of 1 × 0.9 m(2) and an extraction area of 0.1 m(2) using 640 apertures. First results in volume operation, i.e., without caesium seeding, are presented.
Ramos, Eva; Santamaría, Joseba; Santamaría, Gorka; Barbier, Luis; Arteagoitia, Icíar
2016-10-01
The use of antibiotics to prevent dry socket and infection is a controversial but widespread practice. The aim of the study is to assess the efficacy of systemic antibiotics in reducing the frequencies of these complications after extraction. A systematic review and meta-analysis, according to the PRISMA statement, based on randomized double-blind placebo-controlled trials evaluating systemic antibiotics to prevent dry socket and infection after third molar surgery. Databases were searched up to June 2015. Relative risks (RRs) were calculated with inverse variance-weighted, fixed-effect, or random-effect models. We included 22 papers in the qualitative and 21 in the quantitative review (3304 extractions). Overall-RR was 0.43 (95% confidence interval [CI] 0.33-0.56; P < .0001); number needed to treat, 14 (95% CI 11-19). Penicillins-RR: 0.40 (95% CI 0.27-0.59). Nitroimidazoles-RR: 0.56 (95% CI 0.38-0.82). No serious adverse events were reported. Systemic antibiotics significantly reduce the risk of dry socket and infection in third molar extraction. Copyright © 2016 Elsevier Inc. All rights reserved.
In-situ continuous water monitoring system
Thompson, Cyril V.; Wise, Marcus B.
1998-01-01
An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer.
In-situ continuous water monitoring system
Thompson, C.V.; Wise, M.B.
1998-03-31
An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer. 2 figs.
Liu, Shijie
2010-01-01
The conversion of biomass to chemicals and energy is imperative to sustaining our way of life as known to us today. Fossil chemical and energy sources are traditionally regarded as wastes from a distant past. Petroleum, natural gas, and coal are not being regenerated in a sustainable manner. However, biomass sources such as algae, grasses, bushes and forests are continuously being replenished. Woody biomass represents the most abundant and available biomass source. Woody biomass is a reliably sustainable source of chemicals and energy that could be replenished at a rate consistent with our needs. The biorefinery is a concept describing the collection of processes used to convert biomass to chemicals and energy. Woody biomass presents more challenges than cereal grains for conversion to platform chemicals due to its stereochemical structures. Woody biomass can be thought of as comprised of at least four components: extractives, hemicellulose, lignin and cellulose. Each of these four components has a different degree of resistance to chemical, thermal and biological degradation. The biorefinery concept proposed at ESF (State University of New York - College of Environmental Science and Forestry) aims at incremental sequential deconstruction, fractionation/conversion of woody biomass to achieve efficient separation of major components. The emphasis of this work is on the kinetics of hot-water extraction, filling the gap in the fundamental understanding, linking engineering developments, and completing the first step in the biorefinery processes. This first step removes extractives and hemicellulose fractions from woody biomass. While extractives and hemicellulose are largely removed in the extraction liquor, cellulose and lignin largely remain in the residual woody structure. Xylo-oligomers and acetic acid in the extract are the major components having the greatest potential value for development. Extraction/hydrolysis involves at least 16 general reactions that could be divided into four categories: adsorption of proton onto woody biomass, hydrolysis reactions on the woody biomass surface, dissolution of soluble substances into the extraction liquor, and hydrolysis and dehydration decomposition in the extraction liquor. The extraction/hydrolysis rates are significantly simplified when the reactivity of all the intermonomer bonds are regarded as identical within each macromolecule, and the overall reactivity are identical for all the extractable macromolecules on the surface. A pseudo-first order extraction rate expression has been derived based on concentrations in monomer units. The reaction rate constant is however lower at the beginning of the extraction than that towards the end of the extraction. Furthermore, the H-factor and/or severity factor can be applied to lump the effects of temperature and residence time on the extraction process, at least for short times. This provides a means to control and optimize the performance of the extraction process effectively. Copyright 2010 Elsevier Inc. All rights reserved.
Wahlen, Raimund
2004-04-01
A high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) method has been developed for the fast and accurate analysis of arsenobetaine (AsB) in fish samples extracted by accelerated solvent extraction. The combined extraction and analysis approach is validated using certified reference materials for AsB in fish and during a European intercomparison exercise with a blind sample. Up to six species of arsenic (As) can be separated and quantitated in the extracts within a 10-min isocratic elution. The method is optimized so as to minimize time-consuming sample preparation steps and allow for automated extraction and analysis of large sample batches. A comparison of standard addition and external calibration show no significant difference in the results obtained, which indicates that the LC-ICP-MS method is not influenced by severe matrix effects. The extraction procedure can process up to 24 samples in an automated manner, yet the robustness of the developed HPLC-ICP-MS approach is highlighted by the capability to run more than 50 injections per sequence, which equates to a total run-time of more than 12 h. The method can therefore be used to rapidly and accurately assess the proportion of nontoxic AsB in fish samples with high total As content during toxicological screening studies.
Romero-Cerecero, Ofelia; Islas-Garduño, Ana Laura; Zamilpa, Alejandro; Tortoriello, Jaime
2017-06-01
Previous clinical studies have demonstrated the antifungal effectiveness of Ageratina pichinchensis extracts when topically administered to patients with dermatomycosis. The objective of this study was to evaluate the effectiveness and tolerability of a 7% standardized extract of A. pichinchensis (intravaginal) in patients with vulvovaginal candidiasis. The extract was standardized in terms of its encecalin content and administered during 6 days to patients with Candida albicans-associated vulvovaginitis. The positive control group was treated with Clotrimazole (100 mg). On day 7 of the study, a partial evaluation was carried out; it demonstrated that 94.1% of patients treated with Clotrimazole and 100% of those treated with the A. pichinchensis extract referred a decrease or absence of signs and symptoms consistent with vulvovaginal candidiasis. In the final evaluation, 2 weeks after concluding administration, 86.6% of patients in the control group and 81.2% (p = 0.65) of those treated with the A. pichinchensis extract demonstrated therapeutic success. Statistical analysis evidenced no significant differences between the two treatment groups. With the results obtained, it is possible to conclude that the standardized extract from A. pichinchensis, intravaginally administered, showed therapeutic and mycological effectiveness, as well as tolerability, in patients with vulvovaginal candidiasis, without noting statistical differences in patients treated with Clotrimazole. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
2011-01-01
Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. Trial Registration: ISRCTN44464607. PMID:21605352
Nieman, David C; Shanely, R Andrew; Luo, Beibei; Dew, Dustin; Meaney, Mary Pat; Sha, Wei
2013-11-25
The purpose of this study was to assess the effect of 8-weeks ingestion of a commercialized joint pain dietary supplement (Instaflex™ Joint Support, Direct Digital, Charlotte, NC) compared to placebo on joint pain, stiffness, and function in adults with self-reported joint pain. Instaflex™ is a joint pain supplement containing glucosamine sulfate, methylsufonlylmethane (MSM), white willow bark extract (15% salicin), ginger root concentrate, boswella serrata extract (65% boswellic acid), turmeric root extract, cayenne, and hyaluronic acid. Subjects included 100 men and women, ages 50-75 years, with a history (>3 months) of joint pain, and were randomized to Instaflex™ or placebo (3 colored gel capsules per day for 8 weeks, double-blind administration). Subjects agreed to avoid the use of non-steroidal anti-inflammatory drugs (NSAID) and all other medications and supplements targeted for joint pain. Primary outcome measures were obtained pre- and post-study and included joint pain severity, stiffness, and function (Western Ontario and McMaster Universities [WOMAC]), and secondary outcome measures included health-related quality of life (Short Form 36 or SF-36), systemic inflammation (serum C-reactive protein and 9 plasma cytokines), and physical function (6-minute walk test). Joint pain symptom severity was assessed bi-weekly using a 12-point Likert visual scale (12-VS). Joint pain severity was significantly reduced in Instaflex™ compared to placebo (8-week WOMAC, ↓37% versus ↓16%, respectively, interaction effect P = 0.025), with group differences using the 12-VS emerging by week 4 of the study (interaction effect, P = 0.0125). Improvements in ability to perform daily activities and stiffness scores in Instaflex™ compared to placebo were most evident for the 74% of subjects reporting knee pain (8-week WOMAC function score, ↓39% versus ↓14%, respectively, interaction effect P = 0.027; stiffness score, ↓30% versus ↓12%, respectively, interaction effect P = 0.081). Patterns of change in SF-36, systemic inflammation biomarkers, and the 6-minute walk test did not differ significantly between groups during the 8-week study Results from this randomized, double blind, placebo-controlled community trial support the use of the Instaflex™ dietary supplement in alleviating joint pain severity in middle-aged and older adults, with mitigation of difficulty performing daily activities most apparent in subjects with knee pain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, T.; Yang, Z.; Dong, P.
The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H{sup -}) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H{sup -} beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H{sup -} beam current of aboutmore » 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.« less
Solà, Rosa; Valls, Rosa-Maria; Martorell, Isabel; Giralt, Montserrat; Pedret, Anna; Taltavull, Núria; Romeu, Marta; Rodríguez, Àurea; Moriña, David; Lopez de Frutos, Victor; Montero, Manuel; Casajuana, Maria-Carmen; Pérez, Laura; Faba, Jenny; Bernal, Gloria; Astilleros, Anna; González, Roser; Puiggrós, Francesc; Arola, Lluís; Chetrit, Carlos; Martinez-Puig, Daniel
2015-11-01
Preliminary results suggested that oral-administration of rooster comb extract (RCE) rich in hyaluronic acid (HA) was associated with improved muscle strength. Following these promising results, the objective of the present study was to evaluate the effect of low-fat yoghurt supplemented with RCE rich in HA on muscle function in adults with mild knee pain; a symptom of early osteoarthritis. Participants (n = 40) received low-fat yoghurt (125 mL d(-1)) supplemented with 80 mg d(-1) of RCE and the placebo group (n = 40) consumed the same yoghurt without the RCE, in a randomized, controlled, double-blind, parallel trial over 12 weeks. Using an isokinetic dynamometer (Biodex System 4), RCE consumption, compared to control, increased the affected knee peak torque, total work and mean power at 180° s(-1), at least 11% in men (p < 0.05) with no differences in women. No dietary differences were noted. These results suggest that long-term consumption of low-fat yoghurt supplemented with RCE could be a dietary tool to improve muscle strength in men, associated with possible clinical significance. However, further studies are needed to elucidate reasons for these sex difference responses observed, and may provide further insight into muscle function.
Detection of brain tumor margins using optical coherence tomography
NASA Astrophysics Data System (ADS)
Juarez-Chambi, Ronald M.; Kut, Carmen; Rico-Jimenez, Jesus; Campos-Delgado, Daniel U.; Quinones-Hinojosa, Alfredo; Li, Xingde; Jo, Javier
2018-02-01
In brain cancer surgery, it is critical to achieve extensive resection without compromising adjacent healthy, noncancerous regions. Various technological advances have made major contributions in imaging, including intraoperative magnetic imaging (MRI) and computed tomography (CT). However, these technologies have pros and cons in providing quantitative, real-time and three-dimensional (3D) continuous guidance in brain cancer detection. Optical Coherence Tomography (OCT) is a non-invasive, label-free, cost-effective technique capable of imaging tissue in three dimensions and real time. The purpose of this study is to reliably and efficiently discriminate between non-cancer and cancerinfiltrated brain regions using OCT images. To this end, a mathematical model for quantitative evaluation known as the Blind End-Member and Abundances Extraction method (BEAE). This BEAE method is a constrained optimization technique which extracts spatial information from volumetric OCT images. Using this novel method, we are able to discriminate between cancerous and non-cancerous tissues and using logistic regression as a classifier for automatic brain tumor margin detection. Using this technique, we are able to achieve excellent performance using an extensive cross-validation of the training dataset (sensitivity 92.91% and specificity 98.15%) and again using an independent, blinded validation dataset (sensitivity 92.91% and specificity 86.36%). In summary, BEAE is well-suited to differentiate brain tissue which could support the guiding surgery process for tissue resection.
Detection of brain tumor margins using optical coherence tomography
NASA Astrophysics Data System (ADS)
Juarez-Chambi, Ronald M.; Kut, Carmen; Rico-Jimenez, Jesus; Campos-Delgado, Daniel U.; Quinones-Hinojosa, Alfredo; Li, Xingde; Jo, Javier
2018-02-01
In brain cancer surgery, it is critical to achieve extensive resection without compromising adjacent healthy, non-cancerous regions. Various technological advances have made major contributions in imaging, including intraoperative magnetic imaging (MRI) and computed tomography (CT). However, these technologies have pros and cons in providing quantitative, real-time and three-dimensional (3D) continuous guidance in brain cancer detection. Optical Coherence Tomography (OCT) is a non-invasive, label-free, cost-effective technique capable of imaging tissue in three dimensions and real time. The purpose of this study is to reliably and efficiently discriminate between non-cancer and cancer-infiltrated brain regions using OCT images. To this end, a mathematical model for quantitative evaluation known as the Blind End- Member and Abundances Extraction method (BEAE). This BEAE method is a constrained optimization technique which extracts spatial information from volumetric OCT images. Using this novel method, we are able to discriminate between cancerous and non-cancerous tissues and using logistic regression as a classifier for automatic brain tumor margin detection. Using this technique, we are able to achieve excellent performance using an extensive cross-validation of the training dataset (sensitivity 92.91% and specificity 98.15%) and again using an independent, blinded validation dataset (sensitivity 92.91% and specificity 86.36%). In summary, BEAE is well-suited to differentiate brain tissue which could support the guiding surgery process for tissue resection.
Tangen, Jon-Magnus; Tierens, Anne; Caers, Jo; Binsfeld, Marilene; Olstad, Ole Kristoffer; Trøseid, Anne-Marie Siebke; Wang, Junbai; Tjønnfjord, Geir Erland; Hetland, Geir
2015-01-01
Forty patients with multiple myeloma scheduled to undergo high dose chemotherapy with autologous stem cell support were randomized in a double blinded fashion to receive adjuvant treatment with the mushroom extract AndoSan, containing 82% of Agaricus blazei Murrill (19 patients) or placebo (21 patients). Intake of the study product started on the day of stem cell mobilizing chemotherapy and continued until the end of aplasia after high dose chemotherapy, a period of about seven weeks. Thirty-three patients were evaluable for all study endpoints, while all 40 included patients were evaluable for survival endpoints. In the leukapheresis product harvested after stem cell mobilisation, increased percentages of Treg cells and plasmacytoid dendritic cells were found in patients receiving AndoSan. Also, in this group, a significant increase of serum levels of IL-1ra, IL-5, and IL-7 at the end of treatment was found. Whole genome microarray showed increased expression of immunoglobulin genes, Killer Immunoglobulin Receptor (KIR) genes, and HLA genes in the Agaricus group. Furthermore, AndoSan displayed a concentration dependent antiproliferative effect on mouse myeloma cells in vitro. There were no statistically significant differences in treatment response, overall survival, and time to new treatment. The study was registered with Clinicaltrials.gov NCT00970021.
Tierens, Anne; Caers, Jo; Binsfeld, Marilene; Olstad, Ole Kristoffer; Trøseid, Anne-Marie Siebke; Wang, Junbai; Tjønnfjord, Geir Erland; Hetland, Geir
2015-01-01
Forty patients with multiple myeloma scheduled to undergo high dose chemotherapy with autologous stem cell support were randomized in a double blinded fashion to receive adjuvant treatment with the mushroom extract AndoSan, containing 82% of Agaricus blazei Murrill (19 patients) or placebo (21 patients). Intake of the study product started on the day of stem cell mobilizing chemotherapy and continued until the end of aplasia after high dose chemotherapy, a period of about seven weeks. Thirty-three patients were evaluable for all study endpoints, while all 40 included patients were evaluable for survival endpoints. In the leukapheresis product harvested after stem cell mobilisation, increased percentages of Treg cells and plasmacytoid dendritic cells were found in patients receiving AndoSan. Also, in this group, a significant increase of serum levels of IL-1ra, IL-5, and IL-7 at the end of treatment was found. Whole genome microarray showed increased expression of immunoglobulin genes, Killer Immunoglobulin Receptor (KIR) genes, and HLA genes in the Agaricus group. Furthermore, AndoSan displayed a concentration dependent antiproliferative effect on mouse myeloma cells in vitro. There were no statistically significant differences in treatment response, overall survival, and time to new treatment. The study was registered with Clinicaltrials.gov NCT00970021. PMID:25664323
Hwang, Seung Hwan; Li, Hong Mei; Wang, Zhiqiang
2016-01-01
To evaluate the antihyperglycemic effect of a standardized extract of the leaves of Morus alba (SEMA), the present study was designed to investigate the α-glucosidase inhibitory effect and acute single oral toxicity as well as evaluate blood glucose reduction in animals and in patients with impaired glucose tolerance in a randomized double-blind clinical trial. SEMA was found to inhibit α-glucosidase at a fourfold higher level than the positive control (acarbose), in a concentration-dependent manner. Moreover, blood glucose concentration was suppressed by SEMA in vivo. Clinical signs and weight changes were observed when conducting an evaluation of the acute toxicity of SEMA through a single-time administration, with clinical observation conducted more than once each day. After administration of the SEMA, observation was for 14 days; all of the animals did not die and did not show any abnormal symptoms. In addition, the inhibitory effects of rice coated with SEMA were evaluated in a group of impaired glucose tolerance patients on postprandial glucose and a group of normal persons, and results showed that SEMA had a clear inhibitory effect on postprandial hyperglycemia in both groups. Overall, SEMA showed excellent potential in the present study as a material for improving postprandial hyperglycemia. PMID:27974904
Varshney, Ravi; Budoff, Matthew J
2016-02-01
Thousands of studies have been published based on animal and human studies evaluating garlic's effects and safety. We reviewed the available literature investigating the effects of garlic supplements on hypertension, hypercholesterolemia, C-reactive protein (CRP), pulse wave velocity (PWV), and coronary artery calcium (CAC), as well as available data on side effects. We searched PubMed for all human studies using medical subject heading words through 30 May 2013 and assessed relevant review articles and original studies. Only double-blind, randomized, controlled trials and meta-analyses of double-blind, randomized, controlled trials were included. The review of articles and data extraction were performed by 2 independent authors, with any disagreements resolved by consensus. Garlic supplementation reduced blood pressure by 7-16 mm Hg (systolic) and 5-9 mm Hg (diastolic) (4 meta-analyses and 2 original studies). It reduced total cholesterol by 7.4-29.8 mg/dL (8 meta-analyses). The most consistent benefits were shown in studies that used aged garlic extract (AGE). A few small studies that used AGE also showed favorable effects on CAC, CRP, and PWV. Although garlic is generally safe, rare adverse reactions have been documented with limited causality established. We conclude that garlic supplementation has the potential for cardiovascular protection based on risk factor reduction (hypertension and total cholesterol) and surrogate markers (CRP, PWV, and CAC) of atherosclerosis. Larger studies are warranted to evaluate these effects further. © 2016 American Society for Nutrition.
Eshghpour, Majid; Dastmalchi, Parisa; Nekooei, Amir Hossein; Nejat, AmirHossein
2014-08-01
To evaluate the effectiveness of platelet-rich fibrin (PRF) in preventing the development of alveolar osteitis (AO). In a double-blinded study, patients with bilateral impacted mandibular third molars underwent surgical extractions, with one socket receiving PRF and the other one serving as a control. The surgeon and patient were unaware of the study or control side. The predictor variable was the PRF application and was categorized as PRF and non-PRF. The outcome variable was the development of AO during the first postoperative week. Other study variables included age, gender, smoking status, irrigation volume, extraction difficulty, surgeon experience, and number of anesthetic cartridges. Data were analyzed using χ(2) and t tests, with the significance level set at a P value less than .05. Seventy-eight patients (mean age, 25 yr) underwent 156 impacted third molar surgeries. The overall frequency of AO was 14.74% for all surgeries. The frequency of AO in the PRF group was significantly lower than in the non-PRF group (odds ratio = 0.44; P < .05). Based on the results of the present study, PRF application may decrease the risk of AO development after mandibular third molar surgery. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Kim, Do Un; Chung, Hee Chul; Kim, Changhee; Hwang, Jae-Kwan
2017-12-01
Photoaging is a severe skin damage that occurs as a result of exposure to external elements, primarily ultraviolet (UV) irradiation. Chronically, UV-irradiated skin exhibits the signs of sunburn and hyperpigmentation with the destruction of connective tissues. Previously, Boesenbergia pandurata (B. pandurata) and its active compound panduratin A showed antiphotoaging activities in vitro and in vivo. The aim of this study was to investigate the clinical efficacy of B. pandurata intake on skin hydration, gloss, wrinkling, and elasticity. A double-blind, placebo-controlled trial was conducted to clinically evaluate the effect of B. pandurata ethanol extract (BPE) containing 8% of panduratin A on human skin hydration, gloss, wrinkling, and elasticity. Ninety-two subjects were randomly assigned to receive tablets containing either BPE or placebo for 12 weeks. The test group had significantly increased skin hydration and gloss and decreased wrinkling compared to the placebo group at 12 weeks. There was no significant difference in skin elasticity between the two groups; however, the increment rate in the test group was higher than that in the placebo group at 12 weeks. None of the subjects developed adverse symptoms during the study period. These results suggest that BPE can be used as a nutraceutical or nutricosmetic material for improving human skin hydration, gloss, and wrinkling. © 2017 Wiley Periodicals, Inc.
Costabile, Adele; Kolida, Sofia; Klinder, Annett; Gietl, Eva; Bäuerlein, Michael; Frohberg, Claus; Landschütze, Volker; Gibson, Glenn R
2010-10-01
There is growing interest in the use of inulins as substrates for the selective growth of beneficial gut bacteria such as bifidobacteria and lactobacilli because recent studies have established that their prebiotic effect is linked to several health benefits. In the present study, the impact of a very-long-chain inulin (VLCI), derived from globe artichoke (Cynara scolymus), on the human intestinal microbiota compared with maltodextrin was determined. A double-blind, cross-over study was carried out in thirty-two healthy adults who were randomised into two groups and consumed 10 g/d of either VLCI or maltodextrin, for two 3-week study periods, separated by a 3-week washout period. Numbers of faecal bifidobacteria and lactobacilli were significantly higher upon VLCI ingestion compared with the placebo. Additionally, levels of Atopobium group significantly increased, while Bacteroides-Prevotella numbers were significantly reduced. No significant changes in faecal SCFA concentrations were observed. There were no adverse gastrointestinal symptoms apart from a significant increase in mild and moderate bloating upon VLCI ingestion. These observations were also confirmed by in vitro gas production measurements. In conclusion, daily consumption of VLCI extracted from globe artichoke exerted a pronounced prebiotic effect on the human faecal microbiota composition and was well tolerated by all volunteers.
Ito, Tomohiro; Goto, Kazunori; Takanari, Jun; Miura, Takehito; Wakame, Koji; Nishioka, Hiroshi; Tanaka, Aiko; Nishihira, Jun
2014-01-01
Enzyme-treated asparagus extract (ETAS) has been developed as a novel anti-stress functional food ingredient that is produced from asparagus. Two human intervention trials with ETAS were conducted in healthy adult male volunteers. Study 1 was a randomized, double-blind, placebo-controlled study to assess the effects of ETAS on expression of heat shock protein 70 (HSP70) mRNA in blood and the autonomic nervous system (ANS). The ETAS group showed a tendency to enhance HSP70 mRNA expression level compared to the placebo group. Several ANS condition parameters were significantly improved in the ETAS group when compared to the placebo group. In Study 2, a randomized, double-blind, placebo-controlled, crossover trial investigated the influence on stress-related hormones and sleep. Serum and salivary cortisol levels were significantly elevated compared to baseline during the placebo period, but remained unchanged during the ETAS period. The salivary chromogranin A level was significantly decreased in the ETAS-treated subjects compared to their baseline levels. The actual sleep time was not significantly different between ETAS and placebo. However, when the subjects were divided into two categories based on sleep efficiency or the average of night sleeping time, ETAS intake was effective to modulate the sleep state among those with low sleep efficiency or excess sleep time.
Tuk, Jacco G C; van Wijk, Arjen J; Mertens, Ine C; Keleş, Zühal; Lindeboom, Jérôme A H; Milstein, Dan M J
2017-09-01
The aim of this study was to evaluate the analgesic effects of low-level laser therapy (LLLT) on preinjection sites in patients scheduled for third molar removal. This double-blind randomized controlled trial included 163 healthy patients undergoing third molar extractions. The study participants were randomly divided into an LLLT and a placebo group. Objective and subjective data sets were obtained from physiologic feedback (heart rate and sweat response) and a questionnaire, respectively. In the LLLT group, each targeted injection site was irradiated twice with 198 mW continuous wave for 30 seconds with a 0.088 cm 2 focal spot at an applied energy of 5.94 J and fluence of 67.50 J/cm 2 . Measurements were recorded from 4 time-points during data acquisition. There was no significant difference between the LLLT and placebo groups in pain experience scores associated with the injected sites for maxillary or mandibular third molar extractions. Mean heart rates before and during injection were lower in the LLLT group than in the placebo group for both maxillary and mandibular regions. No statistically significant differences were observed for any remaining parameters. The present data indicated that preinjection LLLT did not effectively decrease the pain felt during local anesthetic injections before third molar surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Use of honey associated with Ananas comosus (Bromelin) in the treatment of acute irritative cough.
Peixoto, Décio Medeiros; Rizzo, José Angelo; Schor, Deborah; Silva, Almerinda Rêgo; Oliveira, Dinaldo Cavalcanti de; Solé, Dirceu; Sarinho, Emanuel
2016-12-01
To evaluate the immediate improvement rate of irritative cough in patients treated with the combination of Ananas comosus extract and honey (Bromelin ® ) compared with the use of honey alone (placebo group). Pragmatic, double-blind, randomized, parallel-group study with children aged between 2 and 15 years, with irritative cough for at least 24hours. The double-blind assessment of cough was through the number of observed coughing episodes and intensity score for a period of 10minutes of observation. The decrease of one point in the mean total score was considered as a therapeutic effect. There was a reduction in coughing episodes in both groups, as well as in the cough score after 30minutes of drug or honey administration. The change in clinical score above two points, which could indicate marked improvement, occurred in five patients in the bromelin group and only in one in the placebo group, but without significant difference. There were no adverse events. The immediate improvement rate of irritative cough was similar in patients treated with combination of Ananas comosus extract and honey (Bromelin ® ) compared with the use of honey alone (placebo group). It is possible that honey has a therapeutic effect on mucus and cough characteristics (Clinical Trials: NCT01356693). Copyright © 2016 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Weckwerth, Giovana M.; Simoneti, Luis F.; Zupelari-Gonçalves, Paulo; Calvo, Adriana M.; Brozoski, Daniel T.; Dionísio, Thiago J.; Torres, Elza A.; Lauris, José-Roberto P.; Faria, Flávio-Augusto C.
2017-01-01
Background Using a double-blinded randomized crossover design, this study aimed to evaluate acute postoperative pain management, swelling and trismus in 46 volunteers undergoing extractions of the two lower third molars, in similar positions, at two different appointments who consumed a tablet of either NE (naproxen 500 mg + esomepraz ole 20 mg) or only naproxen (500 mg) every 12 hours for 4 days. Material and Methods Parameters were analyzed: self-reported pain intensity using a visual analog scale (VAS) pre- and postoperative mouth opening; incidence, type and severity of adverse reactions; total quantity consumed of rescue medication; and pre- and postoperative swelling. Results Female volunteers reported significantly more postoperative pain at 1, 1.5, 2, 3 and 4hrs after surgery while also taking their first rescue medication at a time significantly earlier when consuming NE when compared to naproxen (3.7hrs and 6.7hrs). Conversely, no differences were found between each drug group in males. Conclusions In conclusion, throughout the entire study, pain was mild after using either drug in both men and women with pain scores on average well below 40mm (VAS), although in women naproxen improved acute postoperative pain management when compared to NE. Key words:Oral surgery, third molar, pain, naproxen, esomeprazole, NSAIDs. PMID:27918744
Damirchi, Arsalan; Saati Zareei, Alireza; Sariri, Reyhaneh
2015-01-01
Production of reactive oxygen species and reactive nitrogen species is a natural biological event in metabolism. However, the presence of antioxidants can highly reduce the negative effect of free radicals. Thus, the efficiency of antioxidant system in the physiology of exercise is very important. Considering the known antioxidant capacity of garlic, the purpose of this study was to evaluate the effect on combining 14 days aerobic exercise till exhaustion with garlic extract supplementation on the antioxidant capacity of saliva. Sixteen young men volunteered to participate in this randomized, double blind, placebo-controlled study and were randomly placed into two groups, placebo (Group I) and garlic extract (Group II). The participants performed exhaustive aerobic exercise on a treadmill before and after supplementation. Their unstimulated salivary samples were collected before, immediately after, and 1 h after the activity. The antioxidant activity in terms of peroxidase (POD), superoxide dismutase (SOD), and catalase (CAT) was then measured in the collected samples using their specific substrates. A significant increase in salivary antioxidant activity of SOD, POD, and CAT was observed in saliva of the supplement group compared to the placebo group (P ≤ 0.05). The findings from this study suggest that increased activity of antioxidant enzymes could possibly decrease exercise-induced oxidative damage in male athletes.
Information Extraction for System-Software Safety Analysis: Calendar Year 2008 Year-End Report
NASA Technical Reports Server (NTRS)
Malin, Jane T.
2009-01-01
This annual report describes work to integrate a set of tools to support early model-based analysis of failures and hazards due to system-software interactions. The tools perform and assist analysts in the following tasks: 1) extract model parts from text for architecture and safety/hazard models; 2) combine the parts with library information to develop the models for visualization and analysis; 3) perform graph analysis and simulation to identify and evaluate possible paths from hazard sources to vulnerable entities and functions, in nominal and anomalous system-software configurations and scenarios; and 4) identify resulting candidate scenarios for software integration testing. There has been significant technical progress in model extraction from Orion program text sources, architecture model derivation (components and connections) and documentation of extraction sources. Models have been derived from Internal Interface Requirements Documents (IIRDs) and FMEA documents. Linguistic text processing is used to extract model parts and relationships, and the Aerospace Ontology also aids automated model development from the extracted information. Visualizations of these models assist analysts in requirements overview and in checking consistency and completeness.
CONTROLLED RELEASE, BLIND TEST OF DNAPL REMEDIATION BY ETHANOL FLUSHING
A dense nonaqueous phase liquid (DNAPL) source zone was established within a sheet-pile
isolated cell through a controlled release of perchloroethylene (PCE) to evaluate DNAPL
remediation by in-situ cosolvent flushing. Ethanol was used as the cosolvent, and the main remedia...
Development of a compact filament-discharge multi-cusp H- ion source.
Jia, XianLu; Zhang, TianJue; Zheng, Xia; Qin, JiuChang
2012-02-01
A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H(-) ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H(-) ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA∕25 keV H(-) beam with an emittance of 0.3 π mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowder, Jeff; Cornish, Neil J.; Reddinger, J. Lucas
This work presents the first application of the method of genetic algorithms (GAs) to data analysis for the Laser Interferometer Space Antenna (LISA). In the low frequency regime of the LISA band there are expected to be tens of thousands of galactic binary systems that will be emitting gravitational waves detectable by LISA. The challenge of parameter extraction of such a large number of sources in the LISA data stream requires a search method that can efficiently explore the large parameter spaces involved. As signals of many of these sources will overlap, a global search method is desired. GAs representmore » such a global search method for parameter extraction of multiple overlapping sources in the LISA data stream. We find that GAs are able to correctly extract source parameters for overlapping sources. Several optimizations of a basic GA are presented with results derived from applications of the GA searches to simulated LISA data.« less
Farabaugh, Amy; Mischoulon, David; Fava, Maurizio; Wu, Shirley L; Mascarini, Alessandra; Tossani, Eliana; Alpert, Jonathan E
2005-03-01
The 17-item Hamilton Rating Scale for Depression (HAMD-17) Anxiety/Somatization factor includes six items: Anxiety (psychic), Anxiety (somatic), Somatic Symptoms (gastrointestinal), Somatic Symptoms (general), Hypochondriasis and Insight. This study examines the relationship between early changes (defined as those observed between baseline and week 1) in these HAMD-17 Anxiety/Somatization Factor items and treatment outcome among major depressive disorder (MDD) patients who participated in a study comparing the antidepressant efficacy of a standardized extract of hypericum with both placebo and fluoxetine. Following a 1-week, single-blind washout, patients with MDD diagnosed by the Structured Clinical Interview for DSM-IV (SCID) were randomized to 12 weeks of double-blind treatment with hypericum extract (900 mg/day), fluoxetine (20 mg/day) or placebo. The relationship between early changes in HAMD-17 anxiety/somatization factor items and treatment outcome was assessed separately for patients who received study treatment (hypericum or fluoxetine) versus placebo with a logistic regression method. One hundred and thirty-five patients (female 57%, mean age=37.3+/-11.0 years; mean baseline HAMD-17=19.7+/-3.2 years) were randomized to double-blind treatment and were included in the intent-to-treat (ITT) analyses. After adjusting for baseline HAMD-17 scores and for multiple comparisons with the Bonferroni correction, patients who remitted (HAMD-17 score <8) after study treatment had significantly greater early improvement in Somatic Symptoms (General) scores than non-remitters. No other significant differences in early changes were noted for the remaining items between remitters versus non-remitters who received active treatment. For patients treated with placebo, early change was not predictive of remission for any of the items after Bonferroni correction. In conclusion, the presence of early improvement on the HAMD-17 item concerning fatigue and general somatic symptoms is significantly predictive of achieving remission at endpoint with active study treatment but not with placebo.
On using the Hilbert transform for blind identification of complex modes: A practical approach
NASA Astrophysics Data System (ADS)
Antunes, Jose; Debut, Vincent; Piteau, Pilippe; Delaune, Xavier; Borsoi, Laurent
2018-01-01
The modal identification of dynamical systems under operational conditions, when subjected to wide-band unmeasured excitations, is today a viable alternative to more traditional modal identification approaches based on processing sets of measured FRFs or impulse responses. Among current techniques for performing operational modal identification, the so-called blind identification methods are the subject of considerable investigation. In particular, the SOBI (Second-Order Blind Identification) method was found to be quite efficient. SOBI was originally developed for systems with normal modes. To address systems with complex modes, various extension approaches have been proposed, in particular: (a) Using a first-order state-space formulation for the system dynamics; (b) Building complex analytic signals from the measured responses using the Hilbert transform. In this paper we further explore the latter option, which is conceptually interesting while preserving the model order and size. Focus is on applicability of the SOBI technique for extracting the modal responses from analytic signals built from a set of vibratory responses. The novelty of this work is to propose a straightforward computational procedure for obtaining the complex cross-correlation response matrix to be used for the modal identification procedure. After clarifying subtle aspects of the general theoretical framework, we demonstrate that the correlation matrix of the analytic responses can be computed through a Hilbert transform of the real correlation matrix, so that the actual time-domain responses are no longer required for modal identification purposes. The numerical validation of the proposed technique is presented based on time-domain simulations of a conceptual physical multi-modal system, designed to display modes ranging from normal to highly complex, while keeping modal damping low and nearly independent of the modal complexity, and which can prove very interesting in test bench applications. Numerical results for complex modal identifications are presented, and the quality of the identified modal matrix and modal responses, extracted using the complex SOBI technique and implementing the proposed formulation, is assessed.
Ehlers, Kenneth W.; Leung, Ka-Ngo
1988-01-01
A high concentration of positive molecular ions of hydrogen or deuterium gas is extracted from a positive ion source having a short path length of extracted ions, relative to the mean free path of the gas molecules, to minimize the production of other ion species by collision between the positive ions and gas molecules. The ion source has arrays of permanent magnets to produce a multi-cusp magnetic field in regions remote from the plasma grid and the electron emitters, for largely confining the plasma to the space therebetween. The ion source has a chamber which is short in length, relative to its transverse dimensions, and the electron emitters are at an even shorter distance from the plasma grid, which contains one or more extraction apertures.
Chen, Meilian; Kim, Sunghwan; Park, Jae-Eun; Kim, Hyun Sik; Hur, Jin
2016-07-01
Noting the source-dependent properties of dissolved organic matter (DOM), this study explored the recoverable compounds by solid phase extraction (SPE) of two common sorbents (C18 and PPL) eluted with methanol solvent for contrasting DOM sources via fluorescence excitation-emission matrix coupled with parallel factor analysis (EEM-PARAFAC) and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). Fresh algae and leaf litter extracts DOM, one riverine DOM, and one upstream lacustrine DOM were selected for the comparison. C18 sorbent was generally found to extract more diverse molecular formula, relatively higher molecular weight, and more heteroatomic DOM compounds within the studied mass range than PPL sorbent except for the leaf litter extract. Even with the same sorbent, the main molecular features of the two end member DOM were distributed on different sides of the axes of a multivariate ordination, indicating the source-dependent characteristics of the recoverable compounds by the sorbents. In addition, further examination of the molecular formula uniquely present in the two end members and the upstream lake DOM suggested that proteinaceous, tannin-like, and heteroatomic DOM constituents might be potential compound groups which are labile and easily degraded during their mobilization into downstream watershed. This study provides new insights into the sorbent selectivity of DOM from diverse sources and potential lability of various compound groups.
NASA Astrophysics Data System (ADS)
Choi, Woo Young; Woo, Dong-Soo; Choi, Byung Yong; Lee, Jong Duk; Park, Byung-Gook
2004-04-01
We proposed a stable extraction algorithm for threshold voltage using transconductance change method by optimizing node interval. With the algorithm, noise-free gm2 (=dgm/dVGS) profiles can be extracted within one-percent error, which leads to more physically-meaningful threshold voltage calculation by the transconductance change method. The extracted threshold voltage predicts the gate-to-source voltage at which the surface potential is within kT/q of φs=2φf+VSB. Our algorithm makes the transconductance change method more practical by overcoming noise problem. This threshold voltage extraction algorithm yields the threshold roll-off behavior of nanoscale metal oxide semiconductor field effect transistor (MOSFETs) accurately and makes it possible to calculate the surface potential φs at any other point on the drain-to-source current (IDS) versus gate-to-source voltage (VGS) curve. It will provide us with a useful analysis tool in the field of device modeling, simulation and characterization.
Automation for System Safety Analysis
NASA Technical Reports Server (NTRS)
Malin, Jane T.; Fleming, Land; Throop, David; Thronesbery, Carroll; Flores, Joshua; Bennett, Ted; Wennberg, Paul
2009-01-01
This presentation describes work to integrate a set of tools to support early model-based analysis of failures and hazards due to system-software interactions. The tools perform and assist analysts in the following tasks: 1) extract model parts from text for architecture and safety/hazard models; 2) combine the parts with library information to develop the models for visualization and analysis; 3) perform graph analysis and simulation to identify and evaluate possible paths from hazard sources to vulnerable entities and functions, in nominal and anomalous system-software configurations and scenarios; and 4) identify resulting candidate scenarios for software integration testing. There has been significant technical progress in model extraction from Orion program text sources, architecture model derivation (components and connections) and documentation of extraction sources. Models have been derived from Internal Interface Requirements Documents (IIRDs) and FMEA documents. Linguistic text processing is used to extract model parts and relationships, and the Aerospace Ontology also aids automated model development from the extracted information. Visualizations of these models assist analysts in requirements overview and in checking consistency and completeness.
Stanislawski, Larry V.; Survila, Kornelijus; Wendel, Jeffrey; Liu, Yan; Buttenfield, Barbara P.
2018-01-01
This paper describes a workflow for automating the extraction of elevation-derived stream lines using open source tools with parallel computing support and testing the effectiveness of procedures in various terrain conditions within the conterminous United States. Drainage networks are extracted from the US Geological Survey 1/3 arc-second 3D Elevation Program elevation data having a nominal cell size of 10 m. This research demonstrates the utility of open source tools with parallel computing support for extracting connected drainage network patterns and handling depressions in 30 subbasins distributed across humid, dry, and transitional climate regions and in terrain conditions exhibiting a range of slopes. Special attention is given to low-slope terrain, where network connectivity is preserved by generating synthetic stream channels through lake and waterbody polygons. Conflation analysis compares the extracted streams with a 1:24,000-scale National Hydrography Dataset flowline network and shows that similarities are greatest for second- and higher-order tributaries.
The effect of St John’s wort extracts on CYP3A: a systematic review of prospective clinical trials
Whitten, D L; Myers, S P; Hawrelak, J A; Wohlmuth, H
2006-01-01
Aim The aim of this systematic review was to assess the quality and outcomes of clinical trials investigating the effect of St John’s wort extracts on the metabolism of drugs by CYP3A. Methods Prospective clinical trials assessing the effect of St John’s wort (SJW) extracts on metabolism by CYP3A were identified through computer-based searches (from their inception to May 2005) of Medline, Cinahl, PsycINFO, AMED, Current Contents and Embase, hand-searches of bibliographies of relevant papers and consultation with manufacturers and researchers in the field. Two reviewers selected trials for inclusion, independently extracted data and recorded details on study design. Results Thirty-one studies met the eligibility criteria. More than two-thirds of the studies employed a before-and-after design, less than one-third of the studies used a crossover design, and only three studies were double-blind and placebo controlled. In 12 studies the SJW extract had been assayed, and 14 studies stated the specific SJW extract used. Results from 26 studies, including all of the 19 studies that used high-dose hyperforin extracts (>10 mg day−1), had outcomes consistent with CYP3A induction. The three studies using low-dose hyperforin extracts (<4 mg day−1) demonstrated no significant effect on CYP3A. Conclusion There is reasonable evidence to suggest that high-dose hyperforin SJW extracts induce CYP3A. More studies are required to determine whether decreased CYP3A induction occurs after low-dose hyperforin extracts. Future studies should adopt study designs with a control phase or control group, identify the specific SJW extract employed and provide quantitative analyses of key constituents. PMID:17010103
Schorkopf, Dirk Louis P; Hrncir, Michael; Mateus, Sidnei; Zucchi, Ronaldo; Schmidt, Veronika M; Barth, Friedrich G
2009-04-01
Like ants and termites some species of stingless bees (Meliponini), which are very important pollinators in the tropics, use pheromone trails to communicate the location of a food source. We present data on the communicative role of mandibular gland secretions of Meliponini that resolve a recent controversy about their importance in the laying of such trails. Volatile constituents of the mandibular glands have been erroneously thought both to elicit aggressive/defensive behaviour and to signal food source location. We studied Trigona spinipes and Scaptotrigona aff. depilis ('postica'), two sympatric species to which this hypothesis was applied. Using extracts of carefully dissected glands instead of crude cephalic extracts we analysed the substances contained in the mandibular glands of worker bees. Major components of the extracts were 2-heptanol (both species), nonanal (T. spinipes), benzaldehyde and 2-tridecanone (S. aff. depilis). The effect of mandibular gland extracts and of individual components thereof on the behaviour of worker bees near their nest and at highly profitable food sources was consistent. Independent of the amount of mandibular gland extract applied, the bees overwhelmingly reacted with defensive behaviour and were never attracted to feeders scented with mandibular gland extract or any of the synthetic chemicals tested. Both bee species are capable of using mandibular gland secretions for intra- and interspecific communication of defence and aggression and share 2-heptanol as a major pheromone compound. While confirming the role of the mandibular glands in nest defence, our experiments provide strong evidence against their role in food source signalling.
Astronomy with the color blind
NASA Astrophysics Data System (ADS)
Smith, Donald A.; Melrose, Justyn
2014-12-01
The standard method to create dramatic color images in astrophotography is to record multiple black and white images, each with a different color filter in the optical path, and then tint each frame with a color appropriate to the corresponding filter. When combined, the resulting image conveys information about the sources of emission in the field, although one should be cautious in assuming that such an image shows what the subject would "really look like" if a person could see it without the aid of a telescope. The details of how the eye processes light have a significant impact on how such images should be understood, and the step from perception to interpretation is even more problematic when the viewer is color blind. We report here on an approach to manipulating stacked tricolor images that, while abandoning attempts to portray the color distribution "realistically," do result in enabling those suffering from deuteranomaly (the most common form of color blindness) to perceive color distinctions they would otherwise not be able to see.
NavMol 3.0: enabling the representation of metabolic reactions by blind users.
Binev, Yuri; Peixoto, Daniela; Pereira, Florbela; Rodrigues, Ian; Cavaco, Sofia; Lobo, Ana M; Aires-de-Sousa, João
2018-01-01
The representation of metabolic reactions strongly relies on visualization, which is a major barrier for blind users. The NavMol software renders the communication and interpretation of molecular structures and reactions accessible by integrating chemoinformatics and assistive technology. NavMol 3.0 provides a molecular editor for metabolic reactions. The user can start with templates of reactions and build from such cores. Atom-to-atom mapping enables changes in the reactants to be reflected in the products (and vice-versa) and the reaction centres to be automatically identified. Blind users can easily interact with the software using the keyboard and text-to-speech technology. NavMol 3.0 is free and open source under the GNU general public license (GPLv3), and can be downloaded at http://sourceforge.net/projects/navmol as a JAR file. joao@airesdesousa.com. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Mayo-Wilson, Evan; Imdad, Aamer; Herzer, Kurt; Yakoob, Mohammad Yawar
2011-01-01
Objective To determine if vitamin A supplementation is associated with reductions in mortality and morbidity in children aged 6 months to 5 years. Design Systematic review and meta-analysis. Two reviewers independently assessed studies for inclusion. Data were double extracted; discrepancies were resolved by discussion. Meta-analyses were performed for mortality, illness, vision, and side effects. Data sources Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, Medline, Embase, Global Health, Latin American and Caribbean Health Sciences, metaRegister of Controlled Trials, and African Index Medicus. Databases were searched to April 2010 without restriction by language or publication status. Eligibility criteria for selecting studies Randomised trials of synthetic oral vitamin A supplements in children aged 6 months to 5 years. Studies of children with current illness (such as diarrhoea, measles, and HIV), studies of children in hospital, and studies of food fortification or β carotene were excluded. Results 43 trials with about 215 633 children were included. Seventeen trials including 194 483 participants reported a 24% reduction in all cause mortality (rate ratio=0.76, 95% confidence interval 0.69 to 0.83). Seven trials reported a 28% reduction in mortality associated with diarrhoea (0.72, 0.57 to 0.91). Vitamin A supplementation was associated with a reduced incidence of diarrhoea (0.85, 0.82 to 0.87) and measles (0.50, 0.37 to 0.67) and a reduced prevalence of vision problems, including night blindness (0.32, 0.21 to 0.50) and xerophthalmia (0.31, 0.22 to 0.45). Three trials reported an increased risk of vomiting within the first 48 hours of supplementation (2.75, 1.81 to 4.19). Conclusions Vitamin A supplementation is associated with large reductions in mortality, morbidity, and vision problems in a range of settings, and these results cannot be explained by bias. Further placebo controlled trials of vitamin A supplementation in children between 6 and 59 months of age are not required. However, there is a need for further studies comparing different doses and delivery mechanisms (for example, fortification). Until other sources are available, vitamin A supplements should be given to all children at risk of deficiency, particularly in low and middle income countries. PMID:21868478
Operation of large RF sources for H-: Lessons learned at ELISE
NASA Astrophysics Data System (ADS)
Fantz, U.; Wünderlich, D.; Heinemann, B.; Kraus, W.; Riedl, R.
2017-08-01
The goal of the ELISE test facility is to demonstrate that large RF-driven negative ion sources (1 × 1 m2 source area with 360 kW installed RF power) can achieve the parameters required for the ITER beam sources in terms of current densities and beam homogeneity at a filling pressure of 0.3 Pa for pulse lengths of up to one hour. With the experience in operation of the test facility, the beam source inspection and maintenance as well as with the results of the achieved source performance so far, conclusions are drawn for commissioning and operation of the ITER beam sources. Addressed are critical technical RF issues, extrapolations to the required RF power, Cs consumption and Cs ovens, the need of adjusting the magnetic filter field strength as well as the temporal dynamic and spatial asymmetry of the co-extracted electron current. It is proposed to relax the low pressure limit to 0.4 Pa and to replace the fixed electron-to-ion ratio by a power density limit for the extraction grid. This would be highly beneficial for controlling the co-extracted electrons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moran, J. E.; Summa, L.
This was a collaborative effort between the University of California, Lawrence Livermore National Laboratory (LLNL) and Exxon Production Research Company (EPR) to develop improved techniques for extracting, concentrating, and measuring iodine from large volumes of source rock and oil. The purpose of this project was to develop a technique for measuring total iodine extracted from rock, obtain isotopic ratios, and develop age models for samples provided by EPR.
Biosynthesis of Novel Exopolymers by Aureobasidium pullulans
Lee, Jin W.; Yeomans, Walter G.; Allen, Alfred L.; Deng, Fang; Gross, Richard A.; Kaplan, David L.
1999-01-01
Aureobasidium pullulans ATCC 42023 was cultured under aerobic conditions with glucose, mannose, and glucose analogs as energy sources. The exopolymer extracts produced under these conditions were composed of glucose and mannose. The molar ratio of glucose to mannose in the exopolymer extract and the molecular weight of the exopolymer varied depending on the energy source and culture time. The glucose content of exopolymer extracts formed with glucose and mannose as the carbon sources was between 91 and 87%. The molecular weight decreased from 3.5 × 106 to 2.12 × 106 to 0.85 × 106 to 0.77 × 106 with culture time. As the culture time increased, the glucose content of the exopolymer extract formed with glucosamine decreased from 55 ± 3 to 29 ± 2 mol%, and the molecular weight increased from 2.73 × 106 to 4.86 × 106. There was no evidence that glucosamine was directly incorporated into exopolymers. The molar ratios of glucose to mannose in exopolymer extracts ranged from 87 ± 3:13 ± 3 to 28 ± 2:72 ± 2 and were affected by the energy source added. On the basis of the results of an enzyme hydrolysis analysis of the exopolymer extracts and the compositional changes observed, mannose (a repeating unit) was substituted for glucose, which gave rise to a new family of exopolymer analogs. PMID:10583975
Takahashi, T; Ishino, A; Arai, T; Hamada, C; Nakazawa, Y; Iwabuchi, T; Tajima, M
2016-04-01
Androgenetic alopecia (AGA) is a hair loss disorder that commonly affects middle-aged men. To date, the properties of a number of natural or synthetic substances have been investigated for their ability to improve the condition. To evaluate the hair growth-promoting activities of an extract from the root of Sophora flavescens Aiton. We used a human hair keratinocyte proliferation assay and ex vivo organ cultures of human hair follicle to examine the potential of the extract to stimulate hair growth via anagen elongation. We isolated the compounds promoting the growth of epithelial cells, and determined their chemical structures. A randomized, double-blinded, placebo-controlled clinical study for S. flavescens extract was carried out for 6 months with patients with AGA. The extract stimulated the proliferation of hair keratinocytes at a concentration of 0.1 ng/mL, while 100 ng/mL of the extract had a marked effect on hair shaft elongation in an organ culture of human hair follicle. Cell proliferation assay-directed fractionation led to the identification of two pterocarpan derivatives, L-maackiain and medicarpin, as active compounds that promote the proliferation of human hair keratinocytes. Studies in human subjects showed that improvement in the inspected alopecia scores in the lotion plus extract group were significant over a period of 6 months (P < 0.01). S. flavescens root extract is effective for the treatment of AGA. The isolated two pterocarpans might have important role in this effect. © 2015 British Association of Dermatologists.